this report shows a brief and summarised details of the project done at Gisagara in Mukindo sector and it is entitled as MUKINDO WATER PROJECT and it was implemented by EWB Rwanda an partnership with EWB Quebec and it where i did my intership and more of this documenyt is all about the solar power for provision of electric energy to pump the water from down upto hill.

this report shows a brief and summarised details of the project done at Gisagara in Mukindo sector and it is entitled as MUKINDO WATER PROJECT and it was implemented by EWB Rwanda an partnership with EWB Quebec and it where i did my intership and more of this documenyt is all about the solar power for provision of electric energy to pump the water from down upto hill.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

(1) There may be insufficient power reaching the controller.<br />

A solar-direct (non-PowerPack) system should start if there is enough sun to cast a slight<br />

shadow.<br />

(2) If the pump was recently connected (or reconnected) to the controller, it may be running in<br />

reverse direction due to wiring error.<br />

(3) If the motor shaft vibrates, but does not turn, it may be getting power on only two <strong>of</strong> the three<br />

motor wires. This might happen if there is a broken connection or if you accidentally exchanged<br />

one <strong>of</strong> the power wires with the ground wire.<br />

(4) The pump or pipe may be packed with mud, clay, sand or debris.<br />

Service and Maintenance <strong>of</strong> the Controller<br />

Routine inspection and maintenance – To make the controller run stably, a periodic inspection<br />

must be performed every year.<br />

Requirement <strong>of</strong> inspection and maintenance:<br />

(1) The inspection must be performed <strong>by</strong> pr<strong>of</strong>essional technical personnel.<br />

(2) If necessary, cut <strong>of</strong>f the power supply <strong>of</strong> the controller first.<br />

(3) Avoid leaving any metal components in the controller, or else they might cause damage to<br />

the equipment.<br />

(4) An electric insulation test has been made on the controller before it has left factory. A further<br />

test is not necessary.<br />

(5) Do not use the megohmmeter to test the control circuit.<br />

(6) When conducting any insulation test on the motor, you must dismantle the connection<br />

between motor and controller.<br />

Main points for inspection and maintenance<br />

– Please use the controller under the environmental conditions <strong>of</strong> this manual. Inspect and<br />

maintain as per the following table.<br />

Table 10: Inspection overview