Omnetics Based Microwire Arrays<br />

Features:<br />

• Custom configurations up to 32 channels.<br />

• Polyimide-insulated tungsten microwire for excellent recording characteristics and easy insertion.<br />

• An optional epoxy “land” near the recording end of the array maintains electrode spacing.<br />

• Laser cut manufacturing for custom array lengths. Each wire is individually cut to length, so you can<br />

specify an array profile that matches the geometry of your target tissue.<br />

• Optional laser sharpened tips to minimize tissue damage during insertion.<br />

• Lightweight design and small overall array size.<br />

Design Specifications and Ordering Information:<br />

The standard OMN1010 array consists of sixteen channels configured in two rows of eight electrodes each.<br />

[2mm]<br />

[0.25mm]<br />

7mm<br />

9mm<br />

[30mm]<br />

11mm<br />

4mm<br />

[0.50mm]<br />

2mm<br />

Arrays with more than two rows are constructed by stacking and bonding together standard two-row<br />

arrays. These are accessed via multiple 16-channel connectors and headstages.<br />

[0.50mm]<br />

Technical Specifications:<br />

Specification Default Options<br />

Metal:<br />

Tungsten<br />

Insulation:<br />

Polyimide<br />

n Rows X n Electrodes: 2X8 Max channels per connector = 16<br />

Wire Diameter: 50 μm 33 μm<br />

Electrode Spacing: 250 μm 175 μm, 350 μm, 500 μm<br />

Row Seperation: 500 μm 1000 μm, 1500 μm, 2000 μm<br />

Tip Angle: Blunt Cut (0 degrees) 30, 45, 60 degrees<br />

Tip Length: 2mm 0.5mm min to 4mm max<br />

Land Specification: None 5mm, 10mm, 15mm, 20mm, 25mm<br />

Attached G/R Wires: None Ground, Reference<br />

Overall array size:<br />

2mm x 9mm x variable; ~0.3 g (standard array); ~0.5 g (w/shroud & G/R wires)<br />

Connectors:<br />

Omnetics dual row 18-pin nano connector(s) (0.025 mil pitch;