06.03.2018 Views

HEXA Roots Blower (1)

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

JEFFCON ENGINEERING SDN. BHD.<br />

BASE INSTALLATION DIAGRAM (JH-HB SERIES – BELT TRANSMISSION)<br />

UNIT: mm<br />

DEPTH OF HOLE 300<br />

150<br />

A<br />

C<br />

150<br />

D<br />

E<br />

G N O<br />

EXHAUST OUTLET DIRECTION<br />

F<br />

H<br />

B<br />

BELT JOINT (TRANSMISSION) SIZE<br />

Model A B C D E F G H N O<br />

JH-50HB 700 860 270 - - 225 215 410 135 135<br />

JH-65HB 740 900 310 - - 225 215 450 155 155<br />

JH-80HB 760 950 330 - - 225 215 500 175 155<br />

JH-100HB 870 1030 440 - - 225 215 580 205 235<br />

JH-125HB 870 1160 440 - - 230 215 700 220 220<br />

JH-150HB 1240 1450 600 400 350 325 320 750 325 275<br />

JH-175HB 1370 1450 730 400 350 325 320 750 420 310<br />

JH-200HB 1460 1900 820 500 500 450 320 1000 460 360<br />

JH-250HB 1550 2300 900 750 750 400 325 1500 495 405<br />

JH-300HB 1550 2300 900 750 750 400 325 1500 495 405<br />

JH-350AHB 1650 2300 1000 750 750 400 325 1500 670 330<br />

JH-350BHB 1750 2300 1100 750 750 400 325 1500 720 380<br />

Page | 13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!