15.12.2012 Views

Debate Series - Estro-events.org

Debate Series - Estro-events.org

Debate Series - Estro-events.org

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

posTErs<br />

Posters<br />

CliniCal inTERdiSCiPlinaRy PhySiCS RadiObiOlOgy RTT yOung<br />

Page 220 PROgRammE & ExhibiTiOn guidE • ESTRO 31<br />

abS. numbER<br />

> IMRT pre-treatment verification by means of a 3D DVH-based<br />

metric analysis<br />

P. Carrasco de Fez (Spain), N. Jornet Sala, A. Latorre Musoll,<br />

T. Eudaldo Puell, A. Ruiz Martínez, M. Ribas Morales PO-0823<br />

> Rapid Arc treatment verification: post evaluation on delta 4 and<br />

proposal for a new verification protocol<br />

G. Pittomvils (Belgium), L. Paelinck, T. Boterberg, G. De Meerleer,<br />

C. De Wagter PO-0824<br />

> In-vivo dose reconstruction for tangential treatments of breast<br />

cancer: a generalized procedure<br />

F. Greco (Italy), L. Azario, L. Fidanzio, S. Cilla, M. Russo, S. Zucca,<br />

L.C. Orlandini, M. Betti, A. Piermattei PO-0825<br />

> A Pinnacle beam model for the Agility 160-leaf multileaf collimator<br />

J.L. Bedford (United Kingdom), M.D.R. Thomas, G. Smyth,<br />

A.P. Warrington PO-0826<br />

> Small static and RapidArc fields generated by MLC only:<br />

MU calculation accuracy for AAA and Acuros XB<br />

A. Clivio (Switzerland), T. Kron, G. Nicolini, E. Vanetti, L. Cozzi,<br />

A. Fogliata PO-0827<br />

> First clinical experience with offline PET/CT-based in-vivo verification<br />

of scanned carbon ion irradiation<br />

J. Bauer (Germany), D. Unholtz, F. Sommerer, C. Kurz, T. Haberer,<br />

S.E. Combs, T. Welzel, K. Herfarth, J. Debus, K. Parodi PO-0828<br />

> Feasibility study on assessing dose delivery QA with high dose gradient<br />

irradiation<br />

M. Ishikawa (Japan), K. Sutherland, S. Tanabe, N. Tooyama,<br />

Y. Narita, T. Minemura, T. Nishio, H. Tachibana, R. Suzuki,<br />

S. Ishikura PO-0829<br />

Posters<br />

abS. numbER<br />

> Potential for false dose reporting in small field radiation therapy<br />

N. Suchowerska (Australia), A. Ralston, P. Liu, N. Patanjali,<br />

P. Estoesta, D.R. McKenzie PO-0830<br />

> Preliminary results from in vivo dosimetry performed with helical<br />

tomotherapy-based TMI/TLI treatments<br />

F. Pupillo (Italy), M. Zeverino, S. Vagge, S. Agostinelli, R. Corvò,<br />

G. Taccini PO-0831<br />

> VMAT: correlation among 3D dose distribution agreement of 140<br />

patients and the plan optimization parameters<br />

F.R. Giglioli, C. Fiandra, R. Ragona PO-0832<br />

> The implementation of a simple in-vivo dosimetry technique using<br />

the portal imager in a large multi-linac centre<br />

P.A. Rixham (United Kingdom), D.W. Smith, J.R. Sykes, S.J. Weston,<br />

V. Cosgrove PO-0833<br />

> Dosimetric verification of VMAT with Compass®: influence of VMAT<br />

arc discretization<br />

A.H. Ausma (The Netherlands), M.P. Arends, K.J. Visscher PO-0834<br />

> A comparison between several dosimetric methods in IORT<br />

F. Cavagnetto (Italy), S. Agostinelli, L. Ferri, S. Garelli, M. Gusinu,<br />

M. Zeverino, G. Taccini PO-0835<br />

> Photonuclear neutron yields from CRT and IMRT<br />

C. Stokkevåg (Norway) PO-0836<br />

> Statistical control of beam flatness and symmetry in linear accelerators:<br />

differences between protocols<br />

A. Tornero-López (Spain), F. Simancas, S. Ruiz-Arrebola,<br />

J.M. de la Vega, D. Guirado, R. Guerrero, M. Vilches, A.M. Lallena PO-0837<br />

> The effect of dosimetric leaf gap (DLG) parameter on dynamic<br />

IMRT plans<br />

M. Kruszyna (Poland), S. Adamczyk, M. Litoborski, B. Pawalowski PO-0838<br />

ESTRO 31 • PROgRammE & ExhibiTiOn guidE Page 221<br />

posTErs<br />

eSTRO 31

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!