PHYSIOMED-Jubilee
PHYSIOMED-Jubilee
PHYSIOMED-Jubilee
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
THERAPY ICON<br />
PAGE 6<br />
THERAPY FORM<br />
Electrotherapy<br />
<strong>PHYSIOMED</strong>-<strong>Jubilee</strong><br />
Fast therapy start: direct, through program memory or indication index · One-channel electrotherapy unit with wide<br />
selection of low-frequency and medium-frequency currents · Diagnosis<br />
DEVICE DESCRIPTION<br />
The compact <strong>PHYSIOMED</strong>-<strong>Jubilee</strong> electrotherapy device offers<br />
modern electrotherapy as well as the creation of i/t-curves. It features<br />
a large number of low-frequency and medium-frequency<br />
currents, which can be precisely adapted to your treatment by<br />
individually selecting additional parameters (impulse length and<br />
shape, frequency, bursts, biphasic application, and much more).<br />
The divided display offers a comprehensive overview of the therapy<br />
parameters that are currently in use including therapy timers<br />
and intensity chosen. The manual release key functions on the<br />
one hand as a therapy cut-off key (emergency shut-off switch)<br />
for the patient and also enables the use of intentional exercises.
CURRENTS<br />
Medium-frequency<br />
STANDARD ACCESSORIES<br />
CAN BE COMBINED<br />
WITH<br />
· PHYSIOVAC-<strong>Jubilee</strong> for combined vacuum application with vacuum electrodes<br />
TECHNICAL DATA<br />
Low-frequency<br />
[1] Accessory tray<br />
[1] Elastic velcro strap 10 x 125 cm<br />
[1] Elastic velcro strap 6 x 80 cm<br />
[1] Mains cable<br />
[1] Manual release key<br />
[1] Operating instruction<br />
[1] Patient lead (4 connectors)<br />
[2] Plate electrodes EF 50<br />
[1] Short introduction to electrotherapy<br />
[2] Viscose covers EF 50<br />
» FOR ADDITIONAL ACCESSORIES SEE PAGE 10 OR VISIT WWW.<strong>PHYSIOMED</strong>.DE<br />
Protection class 1, Typ BF<br />
Power connection 230 V ±10 % or 115 V ±10 %<br />
Mains frequency 50 – 60 Hz<br />
Current consumption 0.3 A (at 230 V) or 0.6 A (at 115 V)<br />
Power consumption 68 VA<br />
All low-frequency currents except for G, DF, MF, CP and<br />
LP can also be used in biphasic application.<br />
Diadynamic currents optional with galvanic base of 5 %.<br />
» YOU WILL FIND MORE INFORMATION ABOUT THE CURRENT MODES ON PAGE 11<br />
Power output, stimulation current max. 75 mA at 500 Ohm<br />
G = 25 mA at 500 Ohm<br />
Dimensions (W x H x D) 345 x 133 x 348 mm<br />
Weight 5.1 kg<br />
Diagnostics<br />
I/T curve<br />
(graphic representation)<br />
PAGE 7