■ Designed to show superior technology:<br />

The Metasol series<br />

Sealed structure has improved its safety features so<br />

that no arc flash is exposed. In order to emphasize its<br />

durability as an industrial device, Metasol series adopt<br />

simple design form and sophisticated shape applying<br />

diamond cut concepts on product surface.<br />

<strong>LSIS</strong> Meta Solution CONTACTORS


Contents<br />

Table of specifications······················································································ 10<br />

Type numbering system···················································································· 18<br />

Environment······································································································<br />

21<br />

Connections······································································································<br />

22<br />

Control coil characteristics················································································ 24<br />

Marking·············································································································<br />

28<br />

Internal structure·······························································································<br />

29<br />

3-pole <strong>Contactor</strong>s······························································································<br />

30<br />

Motor starters····································································································<br />

52<br />

Reversing contactors························································································ 56<br />

LED voltage monitoring contactor····································································· 58<br />

<strong>Contactor</strong> relays································································································<br />

59<br />

Latching contactors··························································································· 60<br />

4-pole <strong>Contactor</strong>s ····························································································· 64<br />

Enclosed motor starters, Mold enclosure·························································· 74<br />

Enclosed motor starters, Steel enclosure························································· 75<br />

Capacitor contactors························································································· 76<br />

2-pole AC <strong>Contactor</strong>s, Definite purpose··························································· 79<br />

3-pole AC <strong>Contactor</strong>s, Definite purpose··························································· 80<br />

Single-pole AC <strong>Contactor</strong>s, Definite purpose··················································· 81<br />

2-pole DC <strong>Contactor</strong>s······················································································· 82<br />

Accessory·········································································································<br />

83<br />

<strong>Overload</strong> relays·································································································<br />

92<br />

<strong>Overload</strong> relay specifications····································································· 94<br />

<strong>Overload</strong> relay operation·········································································· 100<br />

Accessories for overload relay································································· 102<br />

<strong>Overload</strong> relay ordering types·································································· 106<br />

<strong>Overload</strong> relay trip curves········································································ 112<br />

Type 2 Coordination (380/415V)····································································· 120<br />

Type 2 Coordination (440V)············································································ 123<br />

Type C Coordination (240V)··········································································· 127<br />

Type C Coordination (480V)··········································································· 129<br />

Type C Coordination (600V)··········································································· 130<br />

Type D Coordination (240V)··········································································· 131<br />

Type D Coordination (480V)··········································································· 132<br />

Type D Coordination (600V)··········································································· 133<br />

Rated UL 508 combination motor controller Type-F······································· 134<br />

Ready for IE3··································································································<br />

137<br />

Dimension·······································································································<br />

139<br />

Delayed Opening Device················································································ 175<br />

Electronic timer unit························································································ 176<br />

Contact arrangement······················································································ 177<br />

Comparison table·························································································· 180<br />

Certifications···································································································<br />

186<br />

>>><br />

3


Meta Solution<br />

Series completion<br />

Meta Solution<br />

Meta Solution<br />

Meta Solution<br />

Meta Solution<br />

More Safe,<br />

More Valuable<br />

4<br />

<strong>Contactor</strong>s & <strong>Overload</strong> Relays


•Advanced technology & Expert solution<br />

•Offering economical solution with compact size & easy connection<br />

•Ensure reliability in the system: Type II Coordination<br />

•Perfect system with peripheral devices.<br />

•Environment friendly product: complies with International environment<br />

standard RoHS.<br />

•25Models in 9 Frames 5


<strong>Contactor</strong>s and <strong>Overload</strong> Relays<br />

Motor Starters<br />

•Compact design for space saving<br />

•DIN rail and screw mountable (upto 150AF)<br />

•<strong>Overload</strong> relays directly mountable to contactors<br />

separately<br />

•Finger-proof design<br />

•Easy to combine with manual motor<br />

starters<br />

•Broad range of accessories<br />

•World class products conforming to IEC<br />

and UL standards<br />

18AF<br />

22AF<br />

40AF<br />

65AF<br />

100AF<br />

150AF<br />

<strong>Contactor</strong><br />

MC-6a, 9a, 12a, 18a<br />

Rated current:<br />

6, 9, 12, 18A<br />

Rated insulation voltage:<br />

690V<br />

<strong>Overload</strong> relay MT-12<br />

Current range: 0.1~18A<br />

Trip class: Class10A, 20<br />

<strong>Contactor</strong><br />

MC-9b, 12b, 18b, 22b<br />

Rated current:<br />

9, 12, 18, 22A<br />

Rated insulation voltage:<br />

690V<br />

<strong>Overload</strong> relay MT-32<br />

Current range: 0.1~40A<br />

Trip class: Class10A, 20<br />

<strong>Contactor</strong><br />

MC-32a, 40a<br />

Rated current:<br />

32, 40A<br />

Rated insulation voltage:<br />

1000V<br />

<strong>Overload</strong> relay MT-32<br />

Current range: 0.1~40A<br />

Trip class: Class10A, 20<br />

<strong>Contactor</strong><br />

MC-50a, 65a<br />

Rated current:<br />

50, 65A<br />

Rated insulation voltage:<br />

1000V<br />

<strong>Overload</strong> relay MT-63<br />

Current range: 4~65A<br />

Trip class: Class10A, 20<br />

<strong>Contactor</strong><br />

MC-75a, 85a, 100a<br />

Rated current:<br />

75, 85, 100A<br />

Rated insulation voltage:<br />

1000V<br />

<strong>Overload</strong> relay MT-95<br />

Current range: 7~100A<br />

Trip class: Class10A, 20<br />

<strong>Contactor</strong><br />

MC-130a, 150a<br />

Rated current:<br />

130, 150A<br />

Rated insulation voltage:<br />

1000V<br />

<strong>Overload</strong> relay MT-150<br />

Current range: 34~150A<br />

Trip class: Class10A, 20<br />

6


225AF<br />

400AF<br />

800AF<br />

1260AF<br />

2100AF<br />

<strong>Contactor</strong><br />

MC-185a, 225a<br />

Rated current:<br />

185, 225A<br />

Rated insulation voltage:<br />

1000V<br />

<strong>Overload</strong> relay MT-225<br />

Current range: 65~240A<br />

Trip class: Class10A, 20<br />

<strong>Contactor</strong><br />

MC-265a, 330a, 400a<br />

Rated current:<br />

265, 330, 400A<br />

Rated insulation voltage:<br />

1000V<br />

<strong>Overload</strong> relay MT-400<br />

Current range: 85~400A<br />

Trip class: Class10A, 20<br />

<strong>Contactor</strong><br />

MC-500a, 630a, 800a<br />

Rated current:<br />

500, 630, 800A<br />

Rated insulation voltage:<br />

1000V<br />

<strong>Overload</strong> relay MT-800<br />

Current range: 200~800A<br />

Trip class: Class10A, 20<br />

<strong>Contactor</strong><br />

MC-1260a<br />

Rated current:<br />

1260A<br />

Rated insulation voltage:<br />

1000V<br />

<strong>Contactor</strong><br />

MC-1400a, 1700a, 2100a<br />

Rated current:<br />

1400, 1700, 2100A<br />

Rated insulation voltage:<br />

1000V<br />

7


MC/ TOR<br />

Accessories<br />

Perfect combination of peripheral<br />

devices and various accessories<br />

Offering economical solution with<br />

compact size & easy connection<br />

Perfect system with other devices and accessories<br />

■One-touch connection<br />

•Din Rail connection without any special tools<br />

•Direct combine a surge unit<br />

■Simple wiring<br />

•Mounting unit, Adapter<br />

•Reversing wire set<br />

■Easy Maintenance<br />

•4-terminal type: Easy wiring of operation coil<br />

•Module type of Screw terminal<br />

•Interlock unit with built-in auxiliary contacts(2NO built-in)<br />

8


Advanced accessories for Metasol contactors<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<strong>Contactor</strong><br />

Interlock unit<br />

Auxiliary contact unit<br />

- side mount<br />

Surge unit<br />

Wire kit<br />

Safety cover (Option)<br />

Auxiliary contact unit<br />

- front mount(2p)<br />

Auxiliary contact unit<br />

- front mount(4p)<br />

Mechanical latch unit<br />

Direct adaptor to <strong>MMS</strong><br />

Remote reset unit<br />

<strong>Overload</strong> relay<br />

Separate mounting unit<br />

Mounting unit for use with <strong>MMS</strong>


Table of specifications<br />

MC type<br />

Magnetic <strong>Contactor</strong>s<br />

Frame size<br />

Type<br />

screws clamp terminals<br />

Lug clamp terminals<br />

Number of poles<br />

Rated operational voltage, Ue<br />

Rated insulation voltage, Ui<br />

Rated frequency<br />

Rated impulse withstand voltage, Uimp<br />

Maximum operating rate in operating cycles per hour(AC3)<br />

Durability Mechanical<br />

Electrical<br />

Current AC-1, Thermal current A<br />

and AC-3 200/240V kW<br />

power<br />

A<br />

380/440V kW<br />

A<br />

500/550V kW<br />

A<br />

690V<br />

kW<br />

A<br />

1000V<br />

kW<br />

A<br />

Rated Short-time 1s A<br />

withstand current 10s A<br />

(IEC 60947) 30s A<br />

1min<br />

A<br />

3min<br />

A<br />

10min<br />

A<br />

≥15min<br />

A<br />

UL rating Continuous current A<br />

(50/60Hz) Single 110~120V HP<br />

phase 220~240V HP<br />

200~208V HP<br />

Three 220~240V HP<br />

phase 440~480V HP<br />

550~600V HP<br />

NEMA size<br />

Size AC Weight kg<br />

and control Size(W×H×D) mm<br />

weight DC Weight kg<br />

control Size(W×H×D) mm<br />

Auxiliary(standard)<br />

Auxiliary Side mount<br />

Front mount<br />

Note) Minimum conduct current of Auxiliary contactor is DC 17V 5mA.<br />

18AF<br />

MC-6a MC-9a MC-12a MC-18a<br />

● ● ● ●<br />

3pole<br />

690V<br />

690V<br />

50/60Hz<br />

6kV<br />

1800 operations per hour<br />

15 mil. operations<br />

2.5 mil. operations<br />

25 25 25 32<br />

2.2 2.5 3.5 4.5<br />

9 11 13 18<br />

3 4 5.5 7.5<br />

7 9 12 18<br />

3 4 7.5 7.5<br />

6 7 12 13<br />

3 4 7.5 7.5<br />

4 5 9 9<br />

- - - -<br />

- - - -<br />

210 250 280 300<br />

105 110 120 130<br />

70 70 80 85<br />

61 61 61 70<br />

40 45 47 50<br />

30 30 30 40<br />

25 26 28 40<br />

25 25 25 32<br />

0.5 0.5 0.75 1<br />

1.5 1.5 2 3<br />

2 2 3 7.5<br />

3 3 5 7.5<br />

5 5 7.5 10<br />

7.5 7.5 10 15<br />

00 00 0 1<br />

0.33<br />

45×73.5×80.4<br />

0.4<br />

45×73.5×96.6<br />

1a or 1b<br />

UA-1<br />

UA-2, UA-4<br />

22AF<br />

MC-9b MC-12b MC-18b MC-22b<br />

● ● ● ●<br />

3pole<br />

690V<br />

690V<br />

50/60Hz<br />

6kV<br />

1800 operations per hour<br />

15 mil. operations<br />

2.5 mil. operations<br />

25 25 40 40<br />

2.5 3.5 4.5 5.5<br />

11 13 18 22<br />

4 5.5 7.5 11<br />

9 12 18 22<br />

4 7.5 7.5 15<br />

7 12 13 20<br />

4 7.5 7.5 15<br />

6 9 9 18<br />

- - - -<br />

- - - -<br />

250 280 300 400<br />

110 120 154 186<br />

70 80 100 130<br />

61 61 84 90<br />

45 50 60 60<br />

30 30 40 50<br />

26 28 40 45<br />

25 25 40 40<br />

0.5 0.75 1 2<br />

1.5 2 3 3<br />

2 3 7.5 7.5<br />

3 5 7.5 10<br />

5 7.5 10 15<br />

7.5 10 15 20<br />

00 0 1<br />

0.34<br />

45×73.5×87.4<br />

0.41<br />

45×73.5×103.6<br />

1a1b<br />

UA-1<br />

UA-2, UA-4<br />

MT type<br />

Thermal <strong>Overload</strong> Relays<br />

Type<br />

screws clamp terminals<br />

Lug clamp terminals<br />

Rated operational voltage, Ue<br />

Rated insulation voltage, Ui<br />

Rated impulse withstand voltage, Uimp<br />

Trip class<br />

Setting range<br />

Size<br />

Weight<br />

kg<br />

and<br />

weight<br />

Size(W×H×D) mm<br />

* The safety cover of magnetic contactor and thermal overload relay is optional.<br />

10<br />

MT-12/ <br />

●<br />

690V<br />

690V<br />

6kV<br />

10A, 20<br />

0.1~18A<br />

0.1<br />

45×73.2×63.7<br />

MT-32/ <br />

●<br />

690V<br />

690V<br />

6kV<br />

10A, 20<br />

0.1~40A<br />

0.17<br />

45×75×90


MC-32a<br />

●<br />

40AF<br />

MC-40a<br />

●<br />

3pole<br />

1000V<br />

1000V<br />

50/60Hz<br />

8kV<br />

1800 operations per hour<br />

12 mil. operations<br />

2 mil. operations<br />

50 60<br />

7.5 11<br />

32 40<br />

15 18.5<br />

32 40<br />

18.5 22<br />

28 32<br />

18.5 22<br />

20 23<br />

22 22<br />

17 17<br />

600 700<br />

260 300<br />

160 160<br />

100 100<br />

70 70<br />

55 55<br />

50 50<br />

50 60<br />

2 2<br />

5 5<br />

7.5 15<br />

10 15<br />

20 30<br />

25 30<br />

1P 2<br />

0.55<br />

69×83×90<br />

0.77<br />

69×83×117.1<br />

2a2b<br />

UA-1<br />

UA-2, UA-4<br />

65AF<br />

MC-50a<br />

MC-65a<br />

●<br />

●<br />

●<br />

●<br />

3pole<br />

1000V<br />

1000V<br />

50/60Hz<br />

8kV<br />

1200 operations per hour<br />

12 mil. operations<br />

2 mil. operations<br />

70 100<br />

15 18.5<br />

55 65<br />

22 30<br />

50 65<br />

30 33<br />

43 60<br />

30 33<br />

28 35<br />

30 30<br />

23 23<br />

1000 1050<br />

550 700<br />

330 380<br />

250 270<br />

150 200<br />

90 120<br />

87 100<br />

70 100<br />

3 5<br />

10 15<br />

20 25<br />

25 30<br />

40 50<br />

50 60<br />

1.05<br />

79×106×119<br />

1.3<br />

79×106×146.4<br />

2a2b<br />

UA-1<br />

UA-2, UA-4<br />

100AF<br />

MC-75a MC-85a MC-100a<br />

● ● ●<br />

● ● ●<br />

3pole<br />

1000V<br />

1000V<br />

50/60Hz<br />

8kV<br />

1200 operations per hour<br />

12 mil. operations<br />

2 mil. operations<br />

110 135 160<br />

22 25 30<br />

75 85 105<br />

37 45 55<br />

75 85 105<br />

37 45 55<br />

64 75 85<br />

37 45 55<br />

42 45 65<br />

37 37 37<br />

28 28 28<br />

1100 1200 1320<br />

750 800 900<br />

400 450 500<br />

300 350 400<br />

220 270 270<br />

140 170 180<br />

114 150 160<br />

110 135 160<br />

5 7.5 10<br />

15 15 20<br />

25 30 30<br />

30 40 40<br />

50 60 75<br />

60 75 75<br />

3<br />

1.93<br />

94×140×135.8<br />

2.8<br />

94×140×172.3<br />

2a2b<br />

UA-1<br />

UA-2, UA-4<br />

MT-32/ <br />

●<br />

690V<br />

690V<br />

6kV<br />

10A, 20<br />

0.1~40A<br />

0.17<br />

45×75×90<br />

MT-63/ <br />

●<br />

●<br />

690V<br />

690V<br />

6kV<br />

10A, 20<br />

4~65A<br />

0.31/0.33<br />

55×81×100<br />

MT-95/ <br />

●<br />

●<br />

690V<br />

690V<br />

6kV<br />

10A, 20<br />

7~100A<br />

0.48/0.5<br />

70×97×110<br />

11


Table of specifications<br />

MC type<br />

Magnetic <strong>Contactor</strong>s<br />

Frame size<br />

150AF<br />

225AF<br />

400AF<br />

Type<br />

screws clamp terminals<br />

Lug clamp terminals<br />

Number of poles<br />

Rated operational voltage, Ue<br />

Rated insulation voltage, Ui<br />

Rated frequency<br />

Rated impulse withstand voltage, Uimp<br />

Maximum operating rate in operating cycles per hour(AC3)<br />

Durability Mechanical<br />

Electrical<br />

Current AC-1, Thermal current A<br />

and AC-3 200/240V kW<br />

power<br />

A<br />

380/440V kW<br />

A<br />

500/550V kW<br />

A<br />

690V<br />

kW<br />

A<br />

1000V<br />

kW<br />

A<br />

Rated Short-time 1s A<br />

withstand current 10s A<br />

(IEC 60947) 30s A<br />

1min<br />

A<br />

3min<br />

A<br />

10min<br />

A<br />

≥15min<br />

A<br />

UL rating Continuous current A<br />

(50/60Hz) Single 110~120V HP<br />

phase 220~240V HP<br />

200~208V HP<br />

Three 220~240V HP<br />

phase 440~480V HP<br />

550~600V HP<br />

NEMA size<br />

Size AC Weight kg<br />

and H control Size(W×H×D) mm<br />

weight DC Weight kg<br />

D<br />

W control Size(W×H×D) mm<br />

Auxiliary(standard)<br />

Auxiliary Side mount<br />

Front mount<br />

MC-130a MC-150a<br />

●<br />

●<br />

●<br />

●<br />

3pole<br />

1000V<br />

1000V<br />

50/60Hz<br />

8kV<br />

1200 operations per hour<br />

5 mil. operations<br />

1 mil. operations<br />

200 250<br />

37 45<br />

130 150<br />

60 75<br />

130 150<br />

60 70<br />

90 100<br />

55 55<br />

60 60<br />

75 75<br />

53 53<br />

1350 1800<br />

950 1200<br />

700 800<br />

550 600<br />

350 450<br />

200 300<br />

175 280<br />

160 210<br />

10 15<br />

20 25<br />

40 40<br />

40 50<br />

75 100<br />

75 75<br />

4<br />

2.4<br />

119×158×130.3<br />

2a2b<br />

UA-1<br />

UA-2, UA-4<br />

MC-185a MC-225a<br />

●<br />

●<br />

●<br />

●<br />

3pole<br />

1000V<br />

1000V<br />

50/60Hz<br />

8kV<br />

1200 operations per hour<br />

5 mil. operations<br />

1 mil. operations<br />

300 350<br />

55 75<br />

185 225<br />

90 132<br />

185 225<br />

110 132<br />

180 200<br />

110 140<br />

120 150<br />

132 132<br />

90 90<br />

2000 2500<br />

1500 1700<br />

1000 1200<br />

800 1000<br />

520 700<br />

350 500<br />

320 400<br />

230 275<br />

15 15<br />

30 40<br />

60 60<br />

60 75<br />

125 150<br />

125 150<br />

5.4<br />

138×203×185.1<br />

2a2b<br />

AU-100, AU-100E (Max.4a4b)<br />

-<br />

MC-265a MC-330a MC-400a<br />

● ● ●<br />

3pole<br />

1000V<br />

1000V<br />

50/60Hz<br />

8kV<br />

1200 operations per hour<br />

5 mil. operations 2.5 mil. operations<br />

1 mil. operations 0.5 mil. operations<br />

400 500 520<br />

80 90 125<br />

265 330 400<br />

147 160 200<br />

265 330 400<br />

147 160 225<br />

225 250 350<br />

160 200 250<br />

185 220 300<br />

147 147 147<br />

105 105 105<br />

3500 4000 4600<br />

2400 3000 4400<br />

1500 2500 2974<br />

1100 1700 1846<br />

800 1000 1313<br />

600 620 760<br />

500 553 699<br />

300 350 450<br />

- - -<br />

- - -<br />

75 100 125<br />

100 100 150<br />

200 200 300<br />

200 200 300<br />

5<br />

9.2<br />

163×243×204.4<br />

2a2b<br />

AU-100, AU-100E (Max.4a4b)<br />

-<br />

MT type<br />

Thermal <strong>Overload</strong> Relays<br />

Type<br />

screws clamp terminals<br />

Lug clamp terminals<br />

Rated operational voltage, Ue<br />

Rated insulation voltage, Ui<br />

Rated impulse withstand voltage, Uimp<br />

Trip class<br />

Setting range<br />

Size<br />

Weight<br />

kg<br />

and<br />

weight<br />

Size(W×H×D) mm<br />

MT150/ <br />

●<br />

●<br />

690V<br />

690V<br />

6kV<br />

10A, 20<br />

34~150A<br />

0.67<br />

95×109×113<br />

MT225/ <br />

●<br />

●<br />

690V<br />

690V<br />

6kV<br />

10A, 20<br />

65~240A<br />

2.5<br />

147×141×184<br />

MT400/ <br />

●<br />

690V<br />

690V<br />

6kV<br />

10A, 20<br />

85~400A<br />

2.6<br />

151×171×198<br />

* The safety cover of magnetic contactor and thermal overload relay is optional.<br />

12


800AF<br />

MC-500a MC-630a MC-800a<br />

● ● ●<br />

3pole<br />

1000V<br />

1000V<br />

50/60Hz<br />

8kV<br />

1200 operations per hour<br />

2.5 mil. operations<br />

0.5 mil. operations<br />

700 900 1050<br />

147 190 220<br />

500 630 800<br />

265 330 440<br />

500 630 800<br />

265 330 500<br />

400 500 720<br />

300 400 500<br />

380 420 630<br />

280 280 280<br />

220 220 220<br />

6000 7000 7500<br />

5050 6400 7000<br />

4400 4500 4900<br />

3400 3500 3800<br />

2000 2200 2500<br />

1400 1550 1550<br />

1100 1300 1300<br />

580 660 900<br />

- - -<br />

- - -<br />

150 200 200<br />

200 250 300<br />

400 500 600<br />

400 500 600<br />

6 7<br />

22.4<br />

285×312×245.3<br />

2a2b<br />

AU-100, AU-100E (Max.4a4b)<br />

-<br />

1260AF<br />

MC-1260a<br />

●<br />

3pole<br />

1000V<br />

1000V<br />

50/60Hz<br />

8kV<br />

300 operations per hour<br />

0.5 mil. operations<br />

0.5 mil. operations<br />

1260<br />

-<br />

-<br />

900<br />

1450<br />

-<br />

-<br />

-<br />

-<br />

-<br />

-<br />

8000<br />

7200<br />

5200<br />

4000<br />

2300<br />

3000<br />

1500<br />

-<br />

-<br />

-<br />

23.5<br />

285×352×246<br />

2a2b<br />

AU-100, AU-100E (Max.4a4b)<br />

-<br />

2100AF<br />

MC-1400a MC-1700a MC-2100a<br />

● ● ●<br />

3pole<br />

1000V<br />

1040V<br />

50/60Hz<br />

8kV<br />

300 operations per hour<br />

0.5 mil. operations<br />

0.05 mil. operations<br />

1400 1700 2100<br />

275 320 -<br />

860 1050 -<br />

550 700 900<br />

860 1050 1450<br />

- - -<br />

- - -<br />

860 950 -<br />

860 950 -<br />

- - -<br />

- - -<br />

- - -<br />

8000 10000 10000<br />

- - -<br />

4500 5500 5500<br />

- - -<br />

2600 3000 3000<br />

- - -<br />

1400 1700 2100<br />

- - -<br />

- - -<br />

33.8<br />

431×380×246<br />

2a2b<br />

AU-100, AU-100E (Max.4a4b)<br />

-<br />

MT-800/ <br />

●<br />

690V<br />

690V<br />

6kV<br />

10A, 20<br />

200~800A<br />

11.5<br />

360×530×212<br />

13


Table of specifications<br />

MC type<br />

Magnetic <strong>Contactor</strong>s (4pole)<br />

Frame size<br />

Type<br />

Screw clamp terminal<br />

Number of poles<br />

Rated operational voltage (Ue)<br />

Rated insulation voltage (Ui)<br />

Rated frequency<br />

Rated impulse withstand voltage, Uimp<br />

Maximum operating rate in operating cycles per hour(AC1)<br />

Durability<br />

Mechanical<br />

Electrical<br />

Current Thermal current A<br />

and AC-1 200/240V kW<br />

Power<br />

A<br />

380/400V kW<br />

A<br />

500/550V kW<br />

A<br />

690V<br />

kW<br />

A<br />

UL rating Continuous current A<br />

(50/60Hz) Single 110~120V HP<br />

Phase 220~240V HP<br />

200~208V HP<br />

Three 220~240V HP<br />

Phase 440~480V HP<br />

550~600V HP<br />

Size AC Weight kg<br />

and H Control Size(W×H×D) mm<br />

weight DC Weight kg<br />

D<br />

W<br />

Auxiliary(standard)<br />

Auxiliary<br />

Control Size(W×H×D) mm<br />

Side Mount<br />

Front Mount<br />

18AF<br />

MC-6a/4 MC-9a/4 MC-12a/4 MC-18a/4<br />

●<br />

4pole<br />

690V<br />

690V<br />

50/60Hz<br />

6kV<br />

1800 operations per hour<br />

15 mil. Operations<br />

0.5 mil. Operations 0.8 mil. Operations<br />

25 25 25 40<br />

9 9 9 15<br />

25 25 25 40<br />

17 17 17 27<br />

25 25 25 40<br />

21 21 21 35<br />

25 25 25 40<br />

27 27 27 44<br />

25 25 25 40<br />

25 25 25 32<br />

0.5 0.5 0.75 1<br />

1.5 1.5 2 3<br />

2 2 3 5<br />

3 3 5 7.5<br />

5 5 7.5 10<br />

7.5 7.5 10 15<br />

0.33<br />

45×73.5× 79<br />

0.4<br />

45×73.5×96.6<br />

-<br />

UA-1<br />

UA-2, UA-4<br />

14


22AF<br />

MC-22a/4<br />

●<br />

4pole<br />

690V<br />

690V<br />

50/60Hz<br />

6kV<br />

1800 operations<br />

15 mil. Operations<br />

1 mil. Operations<br />

40<br />

15<br />

40<br />

27<br />

40<br />

35<br />

40<br />

44<br />

40<br />

32<br />

2<br />

3<br />

7.5<br />

7.5<br />

10<br />

15<br />

0.4<br />

47.2×80×86.8<br />

0.5<br />

47.2×80×113.2<br />

-<br />

AU-1<br />

UA-2, UA-4<br />

40AF<br />

MC-32a/4<br />

MC-40a/4<br />

●<br />

4pole<br />

690V<br />

690V<br />

50/60Hz<br />

6kV<br />

1800 operations per hour<br />

15 mil. Operations<br />

1 mil. Operations<br />

50 60<br />

18 22<br />

50 60<br />

35 42<br />

50 60<br />

43 52<br />

50 60<br />

55 66<br />

50 60<br />

45 50<br />

2 3<br />

5 5<br />

7.5 10<br />

10 10<br />

20 25<br />

20 25<br />

0.59<br />

59×83.5×94.5<br />

0.7<br />

59×83.5×121<br />

-<br />

AU-1<br />

UA-2, UA-4<br />

85AF<br />

MC-50a/4 MC-65a/4 MC-75a/4 MC-85a/4<br />

●<br />

4pole<br />

690V<br />

1000V<br />

50/60Hz<br />

8kV<br />

1800 operations per hour<br />

12 mil. Operations<br />

1 mil. Operations<br />

80 100 110 135<br />

30 37 41 51<br />

80 100 110 135<br />

56 70 76 95<br />

80 100 110 135<br />

70 88 97 120<br />

80 100 110 135<br />

88 110 120 150<br />

80 100 110 135<br />

70 80 90 100<br />

3 5 5 7.5<br />

7.5 10 15 15<br />

10 15 20 25<br />

15 20 25 30<br />

30 40 50 50<br />

30 40 50 50<br />

1.2<br />

91×123.5×117.8<br />

1.29<br />

91×123.5×117.8<br />

-<br />

AU-1<br />

UA-2, UA-4<br />

15


Table of specifications<br />

MC type<br />

Magnetic <strong>Contactor</strong>s (4pole)<br />

Frame size<br />

Type<br />

Number of poles<br />

Rated operational voltage (Ue)<br />

Rated insulation voltage (Ui)<br />

Rated frequency<br />

and H Control Size(W×H×D) mm<br />

* - FLA = 722 A, LRA = 5618 A<br />

** - FLA = 566 A, LRA = 4495 A<br />

W<br />

D<br />

Screw clamp terminal<br />

Rated impulse withstand voltage, Uimp<br />

Maximum operating rate in operating cycles per hour(AC1)<br />

Durability<br />

Mechanical<br />

Electrical<br />

Current Thermal current A<br />

and AC-1 200/240V kW<br />

Power<br />

A<br />

380/400V kW<br />

A<br />

500/550V kW<br />

690V<br />

A<br />

kW<br />

UL rating Continuous current A<br />

(50/60Hz) Single 110~120V HP<br />

Phase 220~240V HP<br />

A<br />

200~208V HP<br />

Three 220~240V HP<br />

Phase 440~480V HP<br />

550~600V HP<br />

Size AC Weight kg<br />

weight DC Weight kg<br />

Auxiliary(standard)<br />

Auxiliary<br />

Control Size(W×H×D) mm<br />

Side Mount<br />

Front Mount<br />

225AF<br />

MC-100a/4 MC-130a/4 MC-150a/4 MC-185a/4 MC-225a/4<br />

●<br />

4pole<br />

690V<br />

1000V<br />

50/60Hz<br />

8kV<br />

1200 operations per hour<br />

5 mil. Operations<br />

0.8 mil. Operations<br />

200 250 275 300 350<br />

57 60 76 87 100<br />

150 155 200 230 260<br />

106 110 142 165 185<br />

150 155 200 230 260<br />

132 137 180 205 230<br />

150 155 200 230 260<br />

165 170 225 255 290<br />

150 155 200 230 260<br />

160 160 210 230 275<br />

7.5 10 15 15 15<br />

15 20 25 30 40<br />

30 40 40 60 60<br />

30 40 50 60 75<br />

60 75 100 125 150<br />

60 75 100 125 150<br />

5.6<br />

175×203×185<br />

2NO2NC<br />

AU-100, AU-100E<br />

-<br />

16


400AF<br />

MC-265a/4 MC-330a/4 MC-400a/4<br />

●<br />

4pole<br />

690V<br />

1000V<br />

50/60Hz<br />

8kV<br />

1200 operations per hour<br />

2.5 mil. Operations<br />

0.5 mil. Operations<br />

400 500 520<br />

115 135 160<br />

300 350 420<br />

215 250 300<br />

300 350 420<br />

265 315 375<br />

300 350 420<br />

335 390 470<br />

300 350 420<br />

300 350 450<br />

- - -<br />

- - -<br />

75 100 125<br />

100 125 150<br />

200 250 300<br />

200 250 300<br />

800AF<br />

MC-500a/4 MC-630a/4 MC-800a/4<br />

●<br />

4pole<br />

690V<br />

1000V<br />

50/60Hz<br />

8kV<br />

1200 operations per hour<br />

2.5 mil. Operations<br />

0.5 mil. Operations<br />

700 900 1050<br />

245 255 310<br />

630 660 800<br />

450 470 570<br />

630 660 800<br />

560 590 710<br />

630 660 800<br />

710 740 900<br />

630 660 800<br />

580 660 900<br />

- - -<br />

- - -<br />

150 200 200<br />

200 250 300<br />

400 500 600 *<br />

400 500 600 **<br />

9.9<br />

206×243×205<br />

26.3<br />

346×310 ×244<br />

2NO2NC<br />

AU-100, AU-100E<br />

-<br />

2NO2NC<br />

AU-100, AU-100E<br />

-<br />

17


Type numbering system<br />

<strong>Contactor</strong>s<br />

- - -<br />

MC65A - 40 22 K7 L<br />

Product (6A~2100A) Main contactor Auxiliary contact<br />

Coil voltage<br />

Terminal<br />

MC6A MC-6a<br />

MC2100A MC-2100a<br />

MC9B MC-9b<br />

30 3NO 0NC<br />

40 4NO 0NC<br />

22 2NO 2NC<br />

30 None<br />

40 Normal 1NO Normal 1NC<br />

22 Normal 2NO Normal 2NC<br />

11L Low Current 1NO Low current 1NC<br />

22L Low Current 2NO Low current 2NC<br />

See Coil code Table<br />

*note) See page<br />

23 for details<br />

S Screw<br />

L<br />

Lug<br />

11H<br />

Hoist 1NO Normal 1NC<br />

MC22B<br />

MC-22b<br />

22H<br />

Hoist 2NO Normal 2NC<br />

- A : Metasol A Type<br />

- B : Metasol B Type<br />

ex)<br />

MC65A-30-00-Q7-S-E<br />

MC75A-30-22-H7-L-E<br />

MC-65a AC380V 50/60Hz SCREW (Metasol) EXP<br />

MC-75a AC100V 50/60Hz LUG 2a2b (Metasol) EXP<br />

MC185A-30-22-FV-B-E<br />

MC-185a AC100-240V 50/60Hz, DC100-220V 2a2b (Metasol) EXP<br />

MC85A-40-00-M7-S-E<br />

MC-85a AC220V 50/60Hz 4P (Metasol) EXP<br />

MC800A-40-22-EV-B-E<br />

MC-800a AC/DC200V 2a2b 4P (Metasol) EXP<br />

<strong>Contactor</strong> relays<br />

MR4 - 22L - B7<br />

Product<br />

Main contact<br />

Coil voltage<br />

MR4<br />

MR6<br />

MR8<br />

MR-4<br />

MR-6<br />

MR-8<br />

00 None<br />

13 Normal 1NO Normal 3NC<br />

22 Normal 2NO Normal 2NC<br />

22L Low Current 2NO Low current 2NC<br />

See Coil code Table<br />

*note) See page<br />

23 for details<br />

44 Normal 4NO Normal 4NC<br />

44L<br />

Low Current 2NO Low current 2NC<br />

ex)<br />

MR4-22-B7-E<br />

MR6-42-JD-E<br />

MR8-44-MD-E<br />

MR-4 AC24V 50/60Hz 2a2b (Metasol) EXP<br />

MR-6 DC12V 4a2b (Metasol) EXP<br />

MR-8 DC220V 4a4b (Metasol) EXP<br />

18


Thermal <strong>Overload</strong> Relay<br />

MT-12<br />

- 3H<br />

0.1<br />

Rated current<br />

Relay version<br />

Relay setting current<br />

12 12AF<br />

32 32AF<br />

3H<br />

Non-differential<br />

(3-heater)<br />

0.1 0.1A<br />

63 63AF<br />

3K<br />

Differential<br />

95 95AF<br />

3D Class 20<br />

800 800A<br />

800 800AF<br />

Enclosed Motor starters<br />

MW22B - M -<br />

B<br />

Product<br />

MW6A MW-9a<br />

MW100A MW-100a<br />

Meterial<br />

- Iron<br />

None/Botton<br />

- None<br />

MW9B MW-9b<br />

M<br />

Mold<br />

B<br />

Button<br />

MW22B MW-22b<br />

ex)<br />

MW32aB-30-22-M7-21.5-3H-S-E<br />

MW32A-30-22-N5-34-3H-S-E<br />

MW22BMB-11-Q7-19-SH-S-E<br />

MW-32aB AC220V 50/60Hz SCREW 2a2b 21.5A 3H (Metasol) EXP<br />

MW-32a AC415V 50Hz SCREW 2a2b 34A 3H (Metasol) EXP<br />

MW-22bMB AC380V 50/60Hz SCREW 1a1b 19A 3H (Metasol) EXP<br />

* See page 23 for details<br />

Main Coil Voltage<br />

AC DC Semi-electric (AC) Electric (AC/DC)<br />

50Hz 60Hz 50/60Hz 50/60Hz<br />

Coil Voltage(V) code Coil Voltage(V) code Coil Voltage(V) code Coil Voltage(V) code Coil Voltage(V) code Coil Voltage(V) code<br />

24V B5 24V B6 24V B7 12V JD 100~120 HF 24 (AC24~25 50/60Hz, DC24) AV<br />

48V E5 48V E6 48V E7 24V BD 220~240 MU 48 (AC48~50 50/60Hz, DC24) BV<br />

110V F5 110V F6 110V F7 48V ED 265~347 OQ 24/48 (AC24~50 50/60Hz, DC100~110) CV<br />

220V M5 220V M6 220V M7 110V FD 380~440 OV 100/200 (AC100~240 50/60Hz, DC100~220) FV<br />

380V Q5 380V Q6 380V Q7 125V GD 440~575 S7 100/200 (AC100~240 50/60Hz, DC100~220) DV<br />

415V N5 415V N6 415V N7 220V MD EV<br />

440V R5 440V R6 440V R7 240V OD GV<br />

19


Type numbering system<br />

Optional Accessories<br />

Auxiliary contact unit<br />

UA1<br />

Surge absorber<br />

11 US<br />

11<br />

-<br />

Version<br />

Contact composition<br />

Product Composition<br />

Voltage<br />

UA-1<br />

11 1NO+1NC<br />

Varistor+RC<br />

1 AC 24~48V<br />

AU-100<br />

Side mount<br />

20 2NO<br />

Varistor+RC<br />

2 AC 100~125V<br />

AU-100E<br />

02 2NC<br />

Varistor+RC<br />

3 AC 200~240V<br />

UA-2<br />

Front mount(2P)<br />

40 4NO<br />

Varistor+RC<br />

4 DC 24~48V<br />

UA-4<br />

Front mount(4P)<br />

31 3NO+1NC<br />

Varistor+RC<br />

5 DC 100~125V<br />

Note) UA-2: 2NO, 1NO1NC, 2NC<br />

UA-4: 4NO, 3NO1NC, 4NC,<br />

2NO2NC, 1NO3NC,<br />

22 2NO+2NC<br />

13 1NO+3NC<br />

Varistor+RC<br />

Varistor<br />

6 DC 200~220V<br />

11 AC/DC 24~48V<br />

04 4NC<br />

Varistor<br />

12 AC/DC 100~125V<br />

Varisto<br />

13 AC/DC 200~240V<br />

Varistor<br />

14 AC/DC 380~440V<br />

RC<br />

22 AC 100~125V<br />

Note) See page 82 for details.<br />

UR<br />

Interlock unit<br />

-<br />

02<br />

UW<br />

Wire kit for<br />

Interlocking<br />

-<br />

Separate mounting<br />

unit (For relay)<br />

Remote reset unit<br />

(For relay)<br />

32 UZ - 32<br />

UM -<br />

4R<br />

Product<br />

Contact<br />

composition<br />

Product<br />

Rated current<br />

Product<br />

Rated current<br />

Product<br />

Cable Length<br />

02 2NC<br />

18 18AF<br />

12 12AF<br />

12 12AF<br />

00 None<br />

22 22AF<br />

32 32AF<br />

32 32AF<br />

32 40AF<br />

63 63AF<br />

63 63AF<br />

63 65AF<br />

95 95AF<br />

95 100AF<br />

150 150AF<br />

20


Environment<br />

Environment<br />

Standards<br />

Certifications<br />

IEC/EN 60947-1, IEC/EN 60947-4-1, UL508, K60947<br />

CE, UL, CCC<br />

Rated insulation voltage (Ui) 1000V (6A~22A: 690V, 32A~800A: 1000V)<br />

Rated impulse withstand voltage (Uimp)<br />

Degree of protection<br />

Ambient air temperature<br />

8kV (6A~22A: 6kV, 32A~800A: 8kV)<br />

IP20 (Conforming to IEC60529)<br />

Storage: -30°C ~ +65°C<br />

Operation: -5°C ~ +55°C (AC Type)<br />

Multiple overload current setting<br />

1.5<br />

1.4<br />

1.3<br />

1.2<br />

1.1<br />

1.0<br />

0.96<br />

0.93<br />

0.9<br />

0.86<br />

-5°C ~ +40°C (MT, DC Type)<br />

-25°C ~ +60°C (MT refer to Graph)<br />

Limits of ambient<br />

termperature compensation<br />

to IEC 947-4-1<br />

No Tripping<br />

Tripping<br />

-20 -10 0 10 20 30 40 50 60<br />

Ambient termperature (°C)<br />

Operating altitude<br />

Operating positions<br />

3000m (8900ft)<br />

Shock resistance<br />

Opened: 8G<br />

(1/2 sine wave =11ms) Closed: 10G<br />

Vibration resistance (Conforming to IEC68-2-6) Opened: 2G<br />

(5...300 Hz) Closed: 4G<br />

Flame resistance<br />

Conforming to UL 94: V0<br />

Conforming to IEC 695-2-1: 960°C<br />

21


Connections<br />

Connections<br />

Frame<br />

MC-6a/9a 18~10 / 1~6 18~10 / 1~6 18~10 / 1~6<br />

MC-12a M3.5 16~10 / 1.5~10 16~10 / 1.5~10 16~10 / 1.5~10 8.3 10 1.13 12<br />

MC-18a 16~8 / 1.5~10 16~8 / 1.5~10 16~8 / 1.5~10<br />

MC-9b 18~10 / 1~6 18~10 / 1~6 18~10 / 1~6<br />

MC-12b 18~10 / 1~6 16~10 / 1~6 16~10 / 1~6<br />

M4<br />

MC-18b<br />

18~10 / 1~6 16~8 / 1.5~10 16~8 / 1.5~10<br />

MC-22b 18~10 / 1~6 14~8 / 2.5~10 14~8 / 2.5~10<br />

MC-32a 18~10 / 1~6 12~8 / 2.5~10 12~8 / 2.5~10<br />

M5<br />

MC-40a<br />

18~10 / 1~6 8~6 / 10~16 8~6 / 10~16<br />

MC-50a<br />

M6<br />

- 10~4 / 6~25 10~4 / 6~25<br />

MC-65a - 8~3 / 10~35 8~3 / 10~35<br />

MC-75a - 8~2 / 10~35 8~2 / 10~35<br />

9.6 20 2.25 23<br />

12.8<br />

35 4 41<br />

14 35 4 41<br />

MC-85a M8 - 8~1/0 / 10~50 8~1/0 / 10~50 17 45 5.1 52<br />

MC-100a - 8~2/0 / 10~70 8~2/0 / 10~70<br />

MC-130a<br />

- 3~2/0 / 35~70 3~2/0 / 35~70<br />

M8<br />

MC-150a - 3~4/0 / 35~95 3~4/0 / 35~95<br />

MC-6~150a<br />

Aux./Coil<br />

Wire type<br />

Main<br />

Terminal<br />

Size<br />

(AWG / mm²)<br />

24.5 80 9.1 93<br />

M4 20~14 / 0.5~2.5 18~12 / 0.75~2.5 18~12 / 0.75~2.5 7.6 10 1.13 12<br />

MC-185a<br />

- 1~4/0 / 50~95 1~4/0 / 50~95<br />

M10<br />

MC-225a - 1/0~300 / 50~150 1/0~300 / 50~150<br />

MC-265a - 3/0~500 / 95~240 3/0~500 / 95~240<br />

25 130 14.7 150<br />

MC-330a M12 - 4/0~500 / 95~240 4/0~500 / 95~240 30 200 22.6 230<br />

MC-400a - 350~700 / 185~185×2 350~700 / 185~185×2<br />

MC-500a - 350~800 / 185~240×2 350~800 / 185~240×2<br />

MC-630a M16 - 600~2000 - 40 500 56.5 576<br />

MC-800a - 1700~Busbar -<br />

MC-185~800a<br />

Aux/Coil<br />

M4 16~10 / 1.25~5.5 16~10 / 1.25~5.5 16~10 / 1.25~5.5 7.6 15 1.75 18<br />

MC-1260a M12 - 5mm×100mm×2ea - - 200 22.6 230<br />

MC-1400a<br />

5mm×100mm×2ea<br />

MC-1700a M12 - 5mm×100mm×3ea - - 200 22.6 230<br />

MC-2100a<br />

5mm×100mm×4ea<br />

Torque<br />

mm(max) [Ib-in] [Nm] [kgf·cm]<br />

22


Coil code table<br />

AC DC Semi-electric (AC) Electric (AC/DC)<br />

50Hz 60Hz 50/60Hz - 50/60Hz -<br />

Coil voltage(V) code Coil voltage(V) code Coil voltage(V) code Coil voltage(V) code Coil voltage(V) code Coil voltage(V) code<br />

24 B5 24 B6 24 B7 12 JD 100~120 HF 24 (AC24~25 50/60Hz, DC24) AV<br />

32 C5 32 - 32 - 20 AD 220~240 MU 48 (AC48~50 50/60Hz, DC24) BV<br />

36 CB5 36 - 36 CB7 24 BD 300 (265~247) OQ 24/48 (AC24~50 50/60Hz, DC24~48) CV<br />

42 D5 42 - 42 D7 30 PD 380~440 OV 100/100 (AC100~127 50/60Hz, DC100~110) DV<br />

48 E5 48 E6 48 E7 36 CD 500 (440~575) S7 100/200 (AC100~240 50/60Hz, DC100~220) FV<br />

65 GE5 65 GE6 65 GE7 42 ID 100~120 (LED) HFL 200/200 (AC200~240 50/60Hz, DC200~220) EV<br />

80 G5 80 - 80 - 48 ED 220~240 (LED) MUL 300/400 (AC265~450 50/60Hz) GV<br />

100 H5 100 - 100 H7 60 ND 380~440 (LED) QVL AC 300 (AC265~347 50/60Hz) HV<br />

110 F5 110 F6 110 F7 72 SD AC 400 (AC380~450 50/60Hz) IV<br />

100/110 - 100/110 - 100/110 HF7 80 KS AC 500 (AC440~575 50/60Hz) JV<br />

115 FE5 115 FE6 115 FE7 100 HD<br />

110/120 - 110/120 - 110/120 HK7 110 FD<br />

120 K5 120 K6 120 K7 120 KD<br />

127 KB5 127 KB6 127 KB7 125 GD<br />

175 LC5 175 LC6 175 LC7 200 LD<br />

200 L5 200 L6 200 L7 220 MD<br />

200/208 - 200/208 - 200/208 LJ7 240 OD<br />

208 LB5 208 LB6 208 LB7 250 UD<br />

220 M5 220 M6 220 M7<br />

200/220 - 200/220 - 200/220 LM7<br />

220/230 - 220/230 - 220/230 MP7<br />

220/240 - 220/240 - 220/240 MU7<br />

220L M5L 220L M6L 220L M7L<br />

230 P5 230 - 230 P7<br />

240 U5 240 U6 240 U7<br />

240W U5W 240W - 240W -<br />

230/240 PU5 230/240 PU6 230/240 PU7<br />

240/277 - 240/277 - 240/277 UO7<br />

256 A5 256 A6 256 A7<br />

277 O5 277 O6 277 O7<br />

380 Q5 380 Q6 380 Q7<br />

400 V5 400 - 400 V7<br />

380/400 - 380/400 - 380/400 QV7<br />

415 N5 415 N6 415 N7<br />

440 R5 440 R6 440 R7<br />

400/440 - 400/440 - 400/440 VR7<br />

460 - 460 - 460 RW7<br />

480 W5 480 W6 480 -<br />

500 S5 500 - 500 S7<br />

550 X5 550 - 550 X7<br />

600 T5 600 T6 600 -<br />

23


Control coil characteristics (3pole)<br />

Frame size 18AF 22AF 40AF 65AF 100AF 150AF(A)<br />

MC-6a MC-9b MC-32a MC-50a MC-75a MC-130a<br />

MC-9a MC-12b MC-40a MC-65a MC-85a MC-150a<br />

Type<br />

MC-12a MC-18b MD-30a MC-100a<br />

MC-18a MC-22b MD-60a<br />

MR-4, 6, 8<br />

MD-100a<br />

AC coil<br />

Control voltage<br />

50Hz<br />

60Hz<br />

[Uc]<br />

[V]<br />

[V]<br />

24, 32, 36, 42, 48, 80, 100, 110, 120, 220, 230, 240, 380, 400, 415, 440, 500, 550V<br />

24, 48, 110, 120, 200, 208, 220, 230, 240, 277, 380, 440, 480, 600V<br />

24, 48, 100~240<br />

110~120, 220~240,<br />

300, 380~440,<br />

500V<br />

Voltage limit<br />

[Uc]<br />

85 ~110%<br />

Coil consumption at 20°C<br />

AC 220V Inrush [VA]<br />

60Hz Holding [VA]<br />

70 70 90 110 240 110<br />

9 9 9 13 17 18<br />

Heat dissipation<br />

Operating time<br />

[W]<br />

2.3 2.3 2.7 2.8 5.4 2.7<br />

Closing<br />

Opening<br />

[ms]<br />

[ms]<br />

15 ... 30 15 ... 30 15 ... 30 15 ... 30 15 ... 30 20 ... 40<br />

4 ... 19 4 ... 19 4 ... 19 4 ... 19 10 ... 30 50 ... 70<br />

DC coil<br />

Control voltage<br />

Voltage limit<br />

Coil consumption at 20°C<br />

[Uc]<br />

[Uc]<br />

24, 48, 70~110,<br />

12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250V 100~220, 110, 220V<br />

85~110%<br />

DC 110V Inrush [W]<br />

6 6 9 9 18 213<br />

Holding<br />

Time constant (L/R)<br />

Operating time<br />

Closing<br />

Opening<br />

[W]<br />

[ms]<br />

[ms]<br />

[ms]<br />

6 6 9 9 18 7.5<br />

28 28 28 65 75<br />

40 ... 60 40 ... 60 50 ... 65 50 ... 65 100 ... 120 70 ... 80<br />

4 ... 19 4 ... 19 4 ... 19 4 ... 19 10 ... 25 60 ... 70<br />

Note) Either semi-electronic coil(A) or electronic coil(B) can be chosen for MC-130a and MC-150a<br />

A1 A2 Line<br />

A1<br />

24<br />

A2<br />

Load<br />

Note) A1(A2) in line side is internally connected to A1(A2) in load side.


Frame size 150AF(B) 225AF 400AF 800AF 1260AF 2100AF<br />

MC-130a MC-185a MC-265a MC-500a MC-1260a MC-1400a<br />

Type<br />

MC-150a MC-225a MC-330a MC-630a MC-1700a<br />

MC-400a MC-800a MC-2100a<br />

AC/DC common coil<br />

Control voltage<br />

[Uc]<br />

AC/DC<br />

24/24 DC 24 - - -<br />

24/48<br />

AC/DC 48/48 - 100/100 - -<br />

AC/DC 100~240/100~220 100~240/100~220 100~240/100~220 200/200 100~240/100~220 100~240/100~220<br />

AC - 300 300 300 - -<br />

AC - 400 400 400 - -<br />

AC - 500 500 500 - -<br />

Voltage limit [Uc] 85~110% Note 1)<br />

Coil consumption at 20°C Note 2)<br />

AC 220V Inrush [VA] 320 380 571 1000 1500 2500<br />

50/60Hz Holding [VA] 10 11.6 14 29 24 50<br />

Heat dissipation [W] 4.5 4.7 5 7.8 8.7<br />

Operating time<br />

Closing [ms] 70 70 55 75 75 80<br />

Opening [ms] 70 70 55 75 75 70<br />

Note) 1. Voltage limit for DC 24V coil is 75~110%.<br />

2. Operating time for DC 24V coil is 90ms.<br />

3. Either semi-electronic coil(A) or electronic coil(B) can be chosen for MC-130a and MC-150a<br />

25


Control coil characteristics (4pole)<br />

Frame size 18AF 22AF 40AF 85AF<br />

MC-6a/4P MC-22a/4P MC-32a/4P MC-50a/4P<br />

MC-9a/4P MC-40a/4P MC-65a/4P<br />

Type<br />

MC-12a/4P<br />

MC-18a/4P<br />

MC-75a/4P<br />

MC-85a/4P<br />

AC coil<br />

Control voltage<br />

[Uc]<br />

50Hz<br />

[V]<br />

24, 32, 42, 48, 80, 100,<br />

110, 220, 230, 240, 380,<br />

400, 500, 550<br />

24, 32, 42, 48, 65, 80, 100, 110, 220, 230, 240, 380,<br />

400, 415, 500, 550, 240(wide)<br />

24, 48, 100, 110, 200, 220,<br />

230, 240, 380, 400, 415,<br />

440, 500, 550, 240(wide)<br />

60Hz<br />

[V]<br />

24, 48, 100, 110, 120, 200,<br />

208, 220, 230, 240, 277,<br />

380, 480, 600<br />

24, 48, 110, 120, 208, 220, 240, 277,<br />

380, 440, 480, 600<br />

24, 48, 110, 120, 208, 220,<br />

230, 240, 277, 380, 440,<br />

480, 600<br />

50/60Hz<br />

[V]<br />

24, 48, 100, 110, 120, 200,<br />

220, 230, 20, 380, 415,<br />

440, 500, 550<br />

24, 48, 100, 110, 120, 200, 220, 230, 240,<br />

380, 415, 440, 500, 550<br />

24, 48, 110, 120, 220, 230,<br />

240, 380, 415, 440, 500,<br />

550<br />

Voltage limit 85~110%<br />

Coil consumption at 20°C<br />

AC 220V Inrush [VA] 70 95 95 220<br />

60Hz Holding [VA] 9 9 9 17<br />

Heat dissipation [W] 2.3 2 2 5<br />

Operating time Closing [ms] 15...30 10~17 10~17 16~25<br />

Opening [ms] 4...9 6~9 6~9 8~15<br />

DC coil<br />

Control voltage [Uc] 12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250<br />

Voltage limit 85~110%<br />

Coil consumption at 20°C<br />

DC 100V Inrush [W] 6 9 9 460<br />

(18AF: DC110V) Holding [W] 6 9 9 6<br />

Time constant (L/R) [ms] 28 50 50 -<br />

Operating time Closing [ms] 40...60 45~55 45~55 20~30<br />

Opening [ms] 4...19 8~15 8~15 13~20<br />

26


Frame size 225AF 400AF 800AF<br />

MC-100a/4P MC-265a/4P MC-500a/4P<br />

MC-130a/4P MC-330a/4P MC-630a/4P<br />

Type<br />

MC-150a/4P MC-400a/4P MC-800a/4P<br />

MC-185a/4P<br />

MC-225a/4P<br />

AC/DC common coil<br />

Control voltage<br />

[Uc]<br />

[AC/DC] 24/24 24(DC Only) -<br />

[AC/DC] 48/48 - 100/100<br />

[AC/DC] 100~240/100~220 100~240/100~220 200/200<br />

[AC] 300 300 300<br />

[AC] 400 400 400<br />

[AC] 500 500 500<br />

Voltage limit<br />

85~110% Noet1)<br />

Coil consumption at 20°C Noet2)<br />

AC 220V Inrush [VA] 380 571 1000<br />

50/60Hz Holding [VA] 11.6 14 29<br />

Heat dissipation [W] 4.7 5 7.8<br />

Operating time Closing [ms] 70 55 75<br />

Note) 1. Voltage limit for DC 24V coil is 75~110%.<br />

2. Operating time for DC 24V coil is 90ms.<br />

Opening [ms] 70 55 75<br />

27


Marking<br />

Coil terminal<br />

Upper frame<br />

Lower frame<br />

Main terminal<br />

Terminal numbering<br />

for line side<br />

Brand<br />

Type<br />

Holder<br />

Safety cover<br />

Company logo<br />

Terminal numbering<br />

for load side<br />

Fixing hole<br />

DIN rail mounter<br />

Name plate<br />

Upper cover<br />

Hole for side<br />

mounting accessory<br />

Seat for surge unit connection<br />

Company logo<br />

Type<br />

Product name<br />

Rating<br />

CE marking<br />

UL, CSA rating<br />

UL size<br />

Wire size<br />

Country of origin<br />

Bar code<br />

A, B : Metasol MC<br />

S : Susol MC<br />

Date of manufacture<br />

Certification<br />

(Domestic use only)<br />

28


Internal structure<br />

Safety cover<br />

Arc chamber<br />

Screw terminal kit<br />

Upper frame<br />

Screw terminal kit<br />

Fixed contact<br />

Crossbar<br />

Moving contact<br />

Moving core<br />

Back spring<br />

Coil Ass’y<br />

Fixed core<br />

Rubber<br />

Lower frame<br />

29


<strong>Contactor</strong>s (18AF)<br />

Description<br />

- 3-pole(NO) main contact<br />

- Finger proof design<br />

- DIN rail or screw mountable<br />

- AC or DC control in different physical size<br />

- Front/side mountable accessories available<br />

- Direct mountable overload relay available Rating<br />

- 1NO or 1NC Auxiliary contact built-in as standard.<br />

- Degree of protection: IP20<br />

MC-18a<br />

2pole for DC contact<br />

Rating<br />

<strong>Contactor</strong> type<br />

MC-6a MC-9 a MC-12a MC-18a<br />

kW A kW A kW A kW A<br />

AC duty AC3 200/240V 2.2 9 2.2 11 3.5 13 4.5 18<br />

380/440V 3 7 4 9 5.5 12 7.5 18<br />

500/550V 3 6 4 7 7.5 12 7.5 13<br />

690V 3 4 4 5 7.5 9 7.5 9<br />

AC4 200/240V 1.5 7 1.5 8 2.2 11 3.7 16<br />

380/440V 2.2 5 2.2 6 4 9 4 11<br />

AC1 - 25 - 25 - 25 - 32<br />

DC1 duty 2-pole 24V - 10 - 10 - 12 - 18<br />

(L/R=1ms) in series 48V - 10 - 10 - 12 - 18<br />

110V - 6 - 6 - 10 - 13<br />

3-pole 24V - 10 - 10 - 12 - 18<br />

in series 48V - 10 - 10 - 12 - 18<br />

110V - 8 - 8 - 12 - 18<br />

DC2, 4 duty 2-pole 24V - 8 - 8 - 12 - 12<br />

(L/R=15ms) in series 48V - 4 - 4 - 6 - 6<br />

110V - 2.5 - 2.5 - 4 - 4<br />

3-pole 24V - 8 - 8 - 12 - 12<br />

in series 48V - 6 - 6 - 10 - 10<br />

110V - 4 - 4 - 8 - 8<br />

Directly mountable <strong>Overload</strong> relay<br />

MT-12<br />

Conductor size (solid, stranded) AWG 18~10 16~10 16~8 14~8<br />

(the max. number of conducts: 2) mm² 1~4 1.5~4 1.5~10 2.5~10<br />

Conductor type<br />

65/75℃ Cu-wire only<br />

3pole for DC contact<br />

Coil voltage<br />

50Hz 24, 32, 36, 42, 48, 80, 100, 110, 120, 220, 230, 240, 380, 400, 415, 440, 500, 550V<br />

AC<br />

60Hz 24, 48, 110, 120, 200, 208, 220, 230, 240, 277, 380, 440, 480, 600V<br />

DC DC 12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250V<br />

* Please be cautious for wiring control power cable, especially “ + ” (Positive) and “ - ” (Negative)<br />

polarity should be correctly considered.<br />

Certification<br />

•CE(IEC)<br />

•UL508<br />

•CCC<br />

30


Accessories<br />

Delayed opening<br />

device, AD-9<br />

▶85 page<br />

Surge unit, US<br />

connecting to coil<br />

terminals<br />

▶88 page<br />

Wire kit, UW<br />

for use with Interlock unit<br />

▶86 page<br />

Interlock unit, UR<br />

side mount<br />

▶86 page<br />

Auxiliary contact unit, UA-1<br />

side mount, 1NO+1NC<br />

▶85 page<br />

Mechanical latch unit, ML-65<br />

▶84 page<br />

Auxiliary contact unit, UA-4<br />

front mount, 4P<br />

▶81 page<br />

Auxiliary contact unit, UA-2<br />

front mount, 2P<br />

▶81 page<br />

<strong>Overload</strong> relay, MT<br />

directly mountable to MC type<br />

contactor<br />

▶94 page<br />

Safety cover, A7<br />

▶91 page<br />

31


<strong>Contactor</strong>s (22AF)<br />

Description<br />

- 3-pole(NO) main contact<br />

- Finger proof design<br />

- DIN rail or screw mountable<br />

- AC or DC control in different physical size<br />

- Front/side mountable accessories available<br />

- Direct mountable overload relay available Rating<br />

- 1NO1NC Auxiliary contact built-in as standard.<br />

- UA-1 is available on only left side<br />

- Degree of protection: IP20<br />

Rating<br />

MC-22b<br />

2pole for DC contact<br />

3pole for DC contact<br />

<strong>Contactor</strong> type<br />

MC-9 b MC-12b MC-18b MC-22b<br />

kW A kW A kW A kW A<br />

AC duty AC3 200/240V 2.2 11 3.5 13 4.5 18 5.5 22<br />

380/440V 4 9 5.5 12 7.5 18 11 22<br />

500/550V 4 7 7.5 12 7.5 13 15 20<br />

690V 4 6 7.5 9 7.5 9 15 18<br />

AC4 200/240V 1.5 8 2.2 11 3.7 16 3.7 18<br />

380/440V 2.2 6 4 9 4 11 5.5 13<br />

AC1 - 25 - 25 - 32 - 40<br />

DC1 duty 2-pole 24V - 10 - 12 - 18 - 20<br />

(L/R=1ms) in series 48V - 10 - 12 - 18 - 20<br />

110V - 6 - 10 - 13 - 15<br />

3-pole 24V - 10 - 12 - 18 - 20<br />

in series 48V - 10 - 12 - 18 - 20<br />

110V - 8 - 12 - 18 - 20<br />

DC 2,4 duty 2-pole 24V - 8 - 12 - 12 - 20<br />

(L/R=15ms) in series 48V - 4 - 6 - 6 - 15<br />

110V - 2.5 - 4 - 4 - 8<br />

3-pole 24V - 8 - 12 - 12 - 20<br />

in series 48V - 6 - 10 - 10 - 20<br />

110V - 4 - 8 8 - 15<br />

Directly mountable <strong>Overload</strong> relay<br />

MT-32<br />

Conductor size (solid, stranded) AWG 16~10 16~8 14~8 14~8<br />

(the max. number of conducts: 2) mm² 1.5~4 1.5~10 2.5~10 2.5~10<br />

Conductor type<br />

65/75℃ Cu-wire only<br />

Coil voltage<br />

50Hz 24, 32, 36, 42, 48, 80, 100, 110, 120, 220, 230, 240, 380, 400, 415, 440, 500, 550V<br />

AC<br />

60Hz 24, 48, 110, 120, 200, 208, 220, 230, 240, 277, 380, 440, 480, 600V<br />

DC DC 12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250V<br />

* Please be cautious for wiring control power cable, especially “ + ” (Positive) and “ - ” (Negative)<br />

polarity should be correctly considered.<br />

Certification<br />

•CE(IEC)<br />

•UL508<br />

•CCC<br />

32


Accessories<br />

Wire kit, UW<br />

for use with Interlock unit<br />

▶86 page<br />

Delayed opening<br />

device, AD-9<br />

▶85 page<br />

Surge unit, US<br />

connecting to coil<br />

terminals<br />

▶88 page<br />

Interlock unit, UR<br />

side mount<br />

▶86 page<br />

Auxiliary contact unit, UA-1<br />

side mount, 1NO+1NC<br />

▶85 page<br />

* It is not possible to attach “ UA-1 ”<br />

on the right side of product<br />

Mechanical latch unit, ML-65<br />

▶84 page<br />

Auxiliary contact unit, UA-4<br />

front mount, 4P<br />

▶81 page<br />

Auxiliary contact unit, UA-2<br />

front mount, 2P<br />

▶81 page<br />

<strong>Overload</strong> relay, MT<br />

directly mountable to MC type<br />

contactor<br />

▶94 page<br />

Safety cover, A7<br />

▶91 page<br />

33


<strong>Contactor</strong>s (40AF)<br />

Description<br />

- 3-pole(NO) main contact<br />

- Finger proof design<br />

- DIN rail or screw mountable<br />

- AC or DC control in different physical size<br />

- Front/side mountable accessories available<br />

- Direct mountable overload relay available Rating<br />

- 2NO2NC Auxiliary contact built-in is possible as standard<br />

- Degree of protection: IP20<br />

Rating<br />

MC-40a<br />

2pole for DC contact<br />

3pole for DC contact<br />

<strong>Contactor</strong> type<br />

MC-32a<br />

MC-40a<br />

kW A kW A<br />

AC duty AC3 200/240V 7.5 32 11 40<br />

380/440V 15 32 18.5 40<br />

500/550V 18.5 28 22 32<br />

690V 18.5 20 22 23<br />

1000V 22 17 22 17<br />

AC4 200/240V 4.5 20 5.5 25<br />

380/440V 7.5 17 11 24<br />

AC1 - 50 - 60<br />

DC1 2-pole 24V - 25 - 35<br />

(L/R=1ms) in series 48V - 25 - 35<br />

110V - 25 - 25<br />

3-pole 24V - 25 - 35<br />

in series 48V - 25 - 35<br />

110V - 25 - 35<br />

DC2,4 2-pole 24V - 25 - 35<br />

(L/R=15ms) in series 48V - 20 - 20<br />

110V - 10 - 10<br />

3-pole 24V - 25 - 35<br />

in series 48V - 25 - 30<br />

110V - 20 - 20<br />

Directly mountable <strong>Overload</strong> relay<br />

MT-32<br />

Conductor size (solid, stranded) AWG 12~8 8~6<br />

(the max. number of conducts: 2) mm² 2.5~10 10~16<br />

Conductor type<br />

65/75℃ Cu-wire only<br />

Coil voltage<br />

50Hz 24, 32, 36, 42, 48, 80, 100, 110, 120, 220, 230, 240, 380, 400, 415, 440, 500, 550V<br />

AC<br />

60Hz 24, 48, 110, 120, 200, 208, 220, 230, 240, 277, 380, 440, 480, 600V<br />

DC DC 12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250V<br />

* Please be cautious for wiring control power cable, especially “ + ” (Positive) and “ - ” (Negative)<br />

polarity should be correctly considered.<br />

Certification<br />

•CE(IEC)<br />

•UL508<br />

•CCC<br />

34


Accessories<br />

Wire kit, UW<br />

for use with Interlock unit<br />

▶86 page<br />

Delayed opening<br />

device, AD-9<br />

▶85 page<br />

Surge unit, US<br />

connecting to coil<br />

terminals<br />

▶88 page<br />

Interlock unit, UR<br />

side mount<br />

▶86 page<br />

Auxiliary contact unit, UA-1<br />

side mount, 1NO+1NC<br />

▶85 page<br />

Mechanical latch unit, ML-65<br />

▶84 page<br />

Auxiliary contact unit, UA-4<br />

front mount, 4P<br />

▶81 page<br />

Auxiliary contact unit, UA-2<br />

front mount, 2P<br />

▶81 page<br />

<strong>Overload</strong> relay, MT<br />

directly mountable to MC type<br />

contactor<br />

▶95 page<br />

Safety cover, A7<br />

▶95 page<br />

35


<strong>Contactor</strong>s (65AF)<br />

Description<br />

- 3-pole(NO) main contact<br />

- Finger proof design<br />

- DIN rail or screw mountable<br />

- Both screw and Box terminal (lug) type are available<br />

- AC or DC control in different physical size<br />

- Front/side mountable accessories available<br />

- Direct mountable overload relay available rating<br />

- 2NO2NC Auxiliary contact built-in is possible as standard<br />

- Degree of protection: IP20<br />

Rating<br />

MC-65a<br />

2pole for DC contact<br />

3pole for DC contact<br />

<strong>Contactor</strong> type<br />

MC-50a<br />

MC-65a<br />

kW A kW A<br />

AC duty AC3 200/240V 15 55 18.5 65<br />

380/440V 22 50 30 65<br />

500/550V 30 43 33 60<br />

690V 30 28 33 35<br />

1000V 30 23 30 23<br />

AC4 200/240V 7.5 35 11 50<br />

380/440V 15 32 22 47<br />

AC1 - 70 - 100<br />

DC1 duty 2-pole 24V - 70 - 70<br />

(L/R=1ms) in series 48V - 70 - 70<br />

110V - 35 - 35<br />

3-pole 24V - 50 - 65<br />

in series 48V - 50 - 65<br />

110V - 50 - 65<br />

DC2, 4 duty 2-pole 24V - 45 - 45<br />

(L/R=15ms) in series 48V - 25 - 25<br />

110V - 15 - 15<br />

3-pole 24V - 50 - 50<br />

in series 48V - 35 - 35<br />

110V - 30 - 30<br />

Directly mountable <strong>Overload</strong> relay<br />

MT-63<br />

Conductor size (solid, stranded) AWG 10~4 8~3<br />

(the max. number of conducts: 2) mm² 6~25 10~35<br />

Conductor type<br />

65/75℃ Cu-wire only<br />

36<br />

Coil voltage<br />

50Hz 24, 32, 36, 42, 48, 80, 100, 110, 120, 220, 230, 240, 380, 400, 415, 440, 500, 550V<br />

AC<br />

60Hz 24, 48, 110, 120, 200, 208, 220, 230, 240, 277, 380, 440, 480, 600V<br />

DC DC 12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250V<br />

* Please be cautious for wiring control power cable, especially “ + ” (Positive) and “ - ” (Negative)<br />

polarity should be correctly considered.<br />

Certification<br />

•CE(IEC)<br />

•UL508<br />

•CCC


Accessories<br />

Wire kit, UW<br />

for use with Interlock unit<br />

▶86 page<br />

Delayed opening<br />

device, AD-50<br />

▶85 page<br />

Surge unit, US<br />

connecting to coil<br />

terminals<br />

▶88 page<br />

Interlock unit, UR<br />

side mount<br />

▶86 page<br />

Auxiliary contact unit, UA-1<br />

side mount, 1NO+1NC<br />

▶77 page<br />

Mechanical latch unit, ML-65<br />

▶84 page<br />

Auxiliary contact unit, UA-4<br />

front mount, 4P<br />

▶81 page<br />

Auxiliary contact unit, UA-2<br />

front mount, 2P<br />

▶81 page<br />

<strong>Overload</strong> relay, MT<br />

directly mountable to MC type<br />

contactor<br />

▶91 page<br />

Safety cover, A7<br />

▶87 page<br />

37


<strong>Contactor</strong>s (100AF)<br />

Description<br />

- 3-pole(NO) main contact<br />

- Finger proof design<br />

- DIN rail or screw mountable<br />

- Both screw and Box terminal (lug) type are available<br />

- AC or DC control in different physical size<br />

- Front/side mountable accessories available<br />

- Direct mountable overload relay available Rating<br />

- 2NO2NC Auxiliary contact built-in is possible as standard<br />

- Degree of protection: IP20<br />

Rating<br />

MC-100a<br />

2pole for DC contact<br />

3pole for DC contact<br />

<strong>Contactor</strong> type<br />

MC-75a MC-85a MC-100a<br />

kW A kW A kW A<br />

AC duty AC3 200/240V 22 75 25 85 30 105<br />

380/440V 37 75 45 85 55 105<br />

500/550V 37 64 45 75 55 85<br />

690V 37 42 45 45 45 65<br />

1000V 37 28 37 28 37 28<br />

AC4 200/240V 13 55 15 65 19 80<br />

380/440V 25 52 30 62 37 75<br />

AC1 - 110 - 135 - 160<br />

DC1 duty 2-pole 24V - 75 - 80 - 100<br />

(L/R=1ms) in series 48V - 65 - 65 - 100<br />

110V - 50 - 50 - 80<br />

3-pole 24V - 75 - 80 - 100<br />

in series 48V - 75 - 80 - 100<br />

110V - 75 - 80 - 100<br />

DC2, 4 duty 2-pole 24V - 65 - 65 - 100<br />

(L/R=15ms) in series 48V - 40 - 40 - 60<br />

110V - 20 - 20 - 40<br />

3-pole 24V - 80 - 80 - 100<br />

in series 48V - 60 - 60 - 90<br />

110V - 50 - 50 - 80<br />

Directly mountable <strong>Overload</strong> relay<br />

MT-95<br />

Conductor size (solid, stranded) AWG 8~2 8~0 8~00<br />

(the max. number of conducts: 2) mm² 10~35 10~50 10~70<br />

Conductor type<br />

65/75℃ Cu-wire only<br />

Coil voltage<br />

50Hz 24, 32, 36, 42, 48, 80, 100, 110, 120, 220, 230, 240, 380, 400, 415, 440, 500, 550V<br />

AC<br />

60Hz 24, 48, 110, 120, 200, 208, 220, 230, 240, 277, 380, 440, 480, 600V<br />

DC DC 12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250V<br />

* Please be cautious for wiring control power cable, especially “ + ” (Positive) and “ - ” (Negative)<br />

polarity should be correctly considered.<br />

Certification<br />

•CE(IEC)<br />

•UL508<br />

•CCC<br />

38


Accessories<br />

Wire kit, UW<br />

for use with Interlock unit<br />

▶86 page<br />

Delayed opening<br />

device, AD-50<br />

▶85 page<br />

Surge unit, US<br />

connecting to coil<br />

terminals<br />

▶88 page<br />

Interlock unit, UR<br />

side mount<br />

▶86 page<br />

Auxiliary contact unit, UA-1<br />

side mount, 1NO+1NC<br />

▶85 page<br />

Mechanical latch unit, ML-150<br />

▶84 page<br />

Auxiliary contact unit, UA-4<br />

front mount, 4P<br />

▶81 page<br />

Auxiliary contact unit, UA-2<br />

front mount, 2P<br />

▶81 page<br />

<strong>Overload</strong> relay, MT<br />

directly mountable to MC type<br />

contactor<br />

▶95 page<br />

Safety cover, A7<br />

▶91 page<br />

39


<strong>Contactor</strong>s (150AF)<br />

Description<br />

- 3-pole(NO) main contact<br />

- Finger proof design<br />

- DIN rail or screw mountable<br />

- Both screw and Box terminal (lug) type are available<br />

- AC or DC control in the same physical size<br />

- Front/side mountable accessories available<br />

- Direct mountable overload relay available<br />

- 2NO2NC Auxiliary contact built-in is possible as standard<br />

- Degree of protection: IP20<br />

Rating<br />

MC-150a<br />

2pole for DC contact<br />

3pole for DC contact<br />

<strong>Contactor</strong> type<br />

MC-130a<br />

MC-150a<br />

kW A kW A<br />

AC duty AC3 200/240V 37 130 45 150<br />

380/440V 60 130 75 150<br />

500/550V 60 90 70 100<br />

690V 55 60 55 60<br />

1000V 75 53 75 53<br />

AC4 200/240V 22 93 30 120<br />

380/440V 45 90 55 110<br />

AC1 - 200 - 250<br />

DC1 duty 2-pole 24V - 120 - 150<br />

(L/R=1ms) in series 48V - 100 - 120<br />

110V - 80 - 100<br />

3-pole 24V - 120 - 150<br />

in series 48V - 120 - 150<br />

110V - 100 - 150<br />

DC2,4 duty 2-pole 24V - 120 - 150<br />

(L/R=15ms) in series 48V - 60 - 100<br />

110V - 40 - 80<br />

3-pole 24V - 120 - 150<br />

in series 48V - 90 - 130<br />

110V - 80 - 120<br />

Directly mountable <strong>Overload</strong> relay<br />

MT-150<br />

Conductor size (solid, stranded) AWG 3~00 3~4/0<br />

(the max. number of conducts: 2) mm² 35~70 35~95<br />

Conductor type<br />

65/75℃ Cu-wire only<br />

AC<br />

Coil voltage<br />

AC/DC 100~240 / 100~220<br />

50/60Hz 24, 48, 100~240, 110~120, 220~240, 300, 380~440, 500V<br />

DC DC 24, 48, 70~110, 100~220, 110, 220V<br />

* Please be cautious for wiring control power cable, especially “ + ” (Positive) and “ - ” (Negative)<br />

polarity should be correctly considered.<br />

Certification<br />

•CE(IEC)<br />

•UL508<br />

•CCC<br />

40


Accessories<br />

Delayed opening<br />

device, AD-100<br />

▶85 page<br />

Surge unit, US<br />

connecting to coil<br />

terminals<br />

▶88 page<br />

Busbar<br />

Insulation barrier<br />

▶85 page<br />

Interlock unit, UR<br />

side mount<br />

▶86 page<br />

Auxiliary contact unit, UA-1<br />

side mount, 1NO+1NC<br />

▶81 page<br />

Mechanical latch unit, ML-150<br />

▶84 page<br />

Auxiliary contact unit, UA-4<br />

front mount, 4P<br />

▶81 page<br />

Auxiliary contact unit, UA-2<br />

front mount, 2P<br />

▶81 page<br />

<strong>Overload</strong> relay, MT<br />

directly mountable to MC type<br />

contactor<br />

▶96 page<br />

Safety cover, A7<br />

▶91 page<br />

41


<strong>Contactor</strong>s (225AF)<br />

Description<br />

MC-225a<br />

2pole for DC contact<br />

3pole for DC contact<br />

- 3-pole main contact<br />

- AC/DC common use coil built<br />

- Wide coil operation voltage<br />

- Screw mountable<br />

- 2NO+2NC Auxiliary contacts built-in as standard<br />

- Top/side mountable accessories available<br />

- Direct mountable overload relays available<br />

- Degree of protection: IP20<br />

Rating<br />

<strong>Contactor</strong> type<br />

MC-185a<br />

MC-225a<br />

kW A kW A<br />

AC duty AC3 200/240V 55 185 75 225<br />

380/440V 90 185 132 225<br />

500/550V 110 180 132 200<br />

690V 110 120 140 150<br />

1000V 132 90 132 90<br />

AC4 200/240V 37 150 45 180<br />

380/440V 75 150 90 180<br />

AC1 - 300 - 350<br />

DC1 duty 2-pole 24V - 180 - 220<br />

(L/R=1ms) in series 48V - 180 - 180<br />

110V - 150 - 150<br />

3-pole 24V - 180 - 220<br />

in series 48V - 180 - 220<br />

110V - 180 - 220<br />

DC2, 4 duty 2-pole 24V - 180 - 220<br />

(L/R=15ms) in series 48V - 150 - 150<br />

Directly mountable <strong>Overload</strong> relay<br />

110V - 120 - 120<br />

3-pole 24V - 180 - 220<br />

in series 48V - 180 - 220<br />

110V - 150 - 150<br />

MT-225<br />

Conductor size (solid, stranded) AWG 1~4/0 0~300<br />

(the max. number of conducts: 2) mm² 50~95 50~150<br />

Conductor type<br />

75℃ Cu stranded wire<br />

42<br />

Coil voltage, AC/DC common<br />

Nominal(ordering) voltage AC 50/60Hz DC<br />

24V 24 - 25V 24V<br />

48V 48 - 50V 48V<br />

100/200V 100 - 240V 100 - 220V<br />

300V 265 - 347V -<br />

400V 380 - 450V -<br />

500V 440 - 575V -<br />

Certification<br />

•CE(IEC)<br />

•UL508<br />

•CCC


Accessories<br />

AD-100<br />

Delayed opening device<br />

▶85 page<br />

Safety cover, A7<br />

▶91 page<br />

AU-100, 100E<br />

Auxiliary contact unit<br />

side mount, 1NO+1NC<br />

▶82 page<br />

AP-220<br />

Terminal cover<br />

▶85 page<br />

AR-180<br />

Interlock unit<br />

side mount<br />

▶87 page<br />

AI-180<br />

Insulation barrier<br />

▶85 page<br />

MT-225<br />

<strong>Overload</strong> relay<br />

directly mountable to the contactor<br />

Current range 65~240A<br />

▶97 page<br />

43


<strong>Contactor</strong>s (400AF)<br />

Description<br />

- 3-pole main contact<br />

- AC/DC common use coil built<br />

- Wide coil operation voltage<br />

- Screw mountable<br />

- 2NO+2NC Auxiliary contacts built-in as standard<br />

- Top/side mountable accessories available<br />

- Direct mountable overload relays available<br />

- Degree of protection: IP20<br />

Rating<br />

MC-400a<br />

2pole for DC contact<br />

3pole for DC contact<br />

<strong>Contactor</strong> type<br />

MC-265a MC-330a MC-400a<br />

kW A kW A kW A<br />

AC duty AC3 200/240V 80 265 90 330 125 400<br />

380/440V 147 265 160 330 200 400<br />

500/550V 147 225 160 250 225 350<br />

690V 160 185 200 220 250 300<br />

1000V 147 105 147 105 147 105<br />

AC4 200/240V 50 200 55 220 75 300<br />

380/440V 102 200 110 220 150 300<br />

AC1 - 400 - 500 - 520<br />

DC1 duty 2-pole 24V - 220 - 300 - 400<br />

(L/R=1ms) in series 48V - 180 - 240 - 240<br />

110V - 150 - 200 - 200<br />

3-pole 24V - 220 - 300 - 400<br />

in series 48V - 220 - 300 - 400<br />

110V - 220 - 300 - 400<br />

DC2, 4 duty 2-pole 24V - 220 - 300 - 400<br />

(L/R=15ms) in series 48V - 150 - 200 - 200<br />

110V - 120 - 150 - 150<br />

3-pole 24V - 220 - 300 - 400<br />

in series 48V - 220 - 280 - 280<br />

110V - 150 - 200 - 200<br />

Directly mountable <strong>Overload</strong> relay<br />

MT-400<br />

Conductor size (solid, stranded) AWG 3/0~500 4/0~500 350~700<br />

(the max. number of conducts: 2) mm² 95~240 95~240 185~370<br />

Conductor type<br />

75℃ Cu stranded wire<br />

44<br />

Coil voltage, AC/DC common<br />

Nominal(ordering) voltage AC 50/60Hz DC<br />

100/200V 100 - 240V 100 - 220V<br />

300V 265 - 347V -<br />

400V 380 - 450V -<br />

500V 440 - 575V -<br />

Certification<br />

•CE(IEC)<br />

•UL508<br />

•CCC


Accessories<br />

AD-300<br />

Delayed opening device<br />

▶85 page<br />

Safety cover, A7<br />

▶91 page<br />

AU-100, 100E<br />

Auxiliary contact unit<br />

side mount, 1NO+1NC<br />

▶82 page<br />

AP-400<br />

Terminal cover<br />

▶83 page<br />

AR-180<br />

Interlock unit<br />

side mount<br />

▶87 page<br />

AI-180<br />

Insulation barrier<br />

▶85 page<br />

MT-400<br />

<strong>Overload</strong> relay<br />

directly mountable to the contactor<br />

Current range 85~400A<br />

▶97 page<br />

45


<strong>Contactor</strong>s (800AF)<br />

Description<br />

- 3-pole main contact<br />

- AC/DC common use coil built<br />

- Wide coil operation voltage<br />

- Screw mountable<br />

- 2NO+2NC Auxiliary contacts built-in as standard<br />

- Top/side mountable accessories available<br />

- <strong>Overload</strong> relays available<br />

- Degree of protection: IP20<br />

Rating<br />

MC-800a<br />

2pole for DC contact<br />

3pole for DC contact<br />

<strong>Contactor</strong> type<br />

MC-500a MC-630a MC-800a<br />

kW A kW A kW A<br />

AC duty AC3 200/240V 147 500 190 630 220 800<br />

380/440V 265 500 330 630 440 800<br />

500/550V 265 400 330 500 500 720<br />

690V 300 380 400 420 500 630<br />

1000V 280 220 280 220 280 220<br />

AC4 200/240V 90 350 110 400 160 630<br />

380/440V 176 350 200 400 300 630<br />

AC1 - 700 - 900 - 1050<br />

DC1 duty 2-pole 24V - 400 - 630 - 800<br />

(L/R=1ms) in series 48V - 240 - 630 - 800<br />

110V - 200 - 630 - 630<br />

3-pole 24V - 400 - 630 - 800<br />

in series 48V - 400 - 630 - 800<br />

110V - 400 - 630 - 800<br />

DC2, 4 duty 2-pole 24V - 400 - 630 - 800<br />

(L/R=15ms) in series 48V - 200 - 630 - 630<br />

110V - 150 - 630 - 630<br />

3-pole 24V - 400 - 630 - 800<br />

in series 48V - 280 - 630 - 630<br />

110V - 200 - 630 - 630<br />

Directly mountable <strong>Overload</strong> relay<br />

MT-800<br />

Conductor size (solid, stranded) AWG 350~800 600~2000 1700~Busbar<br />

(the max. number of conducts: 2) mm² 185~480 - -<br />

Conductor type<br />

75℃ Cu stranded wire<br />

46<br />

Coil voltage, AC/DC common<br />

Nominal(ordering) voltage AC 50/60Hz DC<br />

100V 100 - 127V 100 - 110V<br />

200V 200 - 240V 200 - 220V<br />

300V 265 - 347V -<br />

400V 380 - 450V -<br />

500V 440 - 575V -<br />

Certification<br />

•CE(IEC)<br />

•UL508<br />

•CCC


Accessories<br />

AD-600<br />

Delayed opening device<br />

▶85 page<br />

Safety cover, A7<br />

▶91 page<br />

AU-100, 100E<br />

Auxiliary contact unit<br />

side mount, 1NO+1NC<br />

▶82 page<br />

AP-800<br />

Terminal cover<br />

▶85 page<br />

AR-600<br />

Interlock unit<br />

side mount<br />

▶87 page<br />

AI-600<br />

Insulation barrier<br />

▶85 page<br />

MT-800<br />

<strong>Overload</strong> relay<br />

directly mountable to the contactor<br />

Current range 200~800A<br />

▶97 page<br />

47


<strong>Contactor</strong>s (1260AF)<br />

Description<br />

- 3-pole main contact<br />

- AC/DC common use coil built<br />

- Wide coil operation voltage<br />

- Screw mountable<br />

- 2NO+2NC Auxiliary contacts built-in as standard<br />

- Top/side mountable accessories available<br />

- <strong>Overload</strong> relays available<br />

- Degree of protection: IP20<br />

Rating<br />

MC-1260a<br />

MC-1260a<br />

<strong>Contactor</strong> type<br />

kW<br />

A<br />

AC duty AC3 200/240V - -<br />

380/440V 900 1450<br />

500/550V - -<br />

690V - -<br />

1000V - -<br />

AC1 - 1260<br />

Conductor size (solid, stranded) Bubar 5mm×100mm×2ea<br />

Conductor type<br />

Busbar<br />

Coil voltage, AC/DC common<br />

Nominal(ordering) voltage AC 50/60Hz DC<br />

100V / 200V 100 - 240V 100 - 220V<br />

Certification<br />

•CE(IEC)<br />

•UL, UL/cUL<br />

2pole for DC contact<br />

3pole for DC contact<br />

48


Accessories<br />

AU-100, 100E<br />

Auxiliary contact unit<br />

side mount, 1NO+1NC<br />

▶82 page<br />

AI-800<br />

Insulation barrier<br />

▶85 page<br />

49


<strong>Contactor</strong>s (2100AF)<br />

Description<br />

- 3-pole main contact<br />

- AC/DC common use coil built<br />

- Wide coil operation voltage<br />

- Screw mountable<br />

- 2NO+2NC Auxiliary contacts built-in as standard<br />

- Top/side mountable accessories available<br />

- <strong>Overload</strong> relays available<br />

- Degree of protection: IP20<br />

Rating<br />

MC-2100a<br />

<strong>Contactor</strong> type<br />

MC-1400a MC-1700a MC-2100a<br />

kW A kW A kW A<br />

AC duty AC3 200/240V 290 860 310 1050 - -<br />

380/440V 550 860 700 1050 900 1450<br />

500/550V - - - - - -<br />

690V 800 800 1000 950 - -<br />

1000V - - - - - -<br />

AC1 - 1400 - 1700 - 2100<br />

Conductor size (solid, stranded) Busbar 5mm×100mm×2ea 5mm×100mm×2ea 5mm×100mm×2ea<br />

Conductor type<br />

Busbar<br />

Coil voltage, AC/DC common<br />

Nominal(ordering) voltage AC 50/60Hz DC<br />

100V / 200V 100 - 240V 100 - 220V<br />

Certification<br />

•CE(IEC)<br />

•UL60947-4-1<br />

•CCC<br />

50


Accessories<br />

AU-100, 100E<br />

Auxiliary contact unit<br />

side mount, 1NO+1NC<br />

▶82 page<br />

AI-2100<br />

Insulation barrier<br />

▶85 page<br />

51


Motor starters<br />

Description<br />

- Opened direct motor starter<br />

- 3-pole(NO) main contact<br />

- Finger proof design<br />

- DIN rail or screw mountable<br />

- AC or DC control contactor selectable<br />

- Front/side mountable accessories available<br />

- <strong>Overload</strong> relay is directly mounted to the contactor<br />

- Degree of protection: IP20<br />

Rating<br />

Starter type<br />

18AF<br />

22AF<br />

MS-6a MS-9a MS-12a MS-18a MS-9b MS-12b MS-18b MS-22b<br />

Number of poles 3 3<br />

Rated operational voltage (Ue) 690V 690V<br />

Degree of pollution (IEC60529) IP20 IP20<br />

Rated operational current Ie (θ≤40℃)<br />

AC-1 Ue max 690V A 25 25 25 32 25 25 32 40<br />

AC-3 200/240V A 9 11 13 18 11 13 18 22<br />

380/400V A 7 9 12 18 9 12 18 22<br />

415V A 7 9 12 18 9 12 18 22<br />

440V A 7 9 12 18 9 12 18 22<br />

500V A 6 7 12 13 7 12 13 20<br />

690V A 4 5 9 9 6 9 9 18<br />

` 1000V A - - - - - - - -<br />

Rated operational power (θ≤40℃)<br />

AC-3 200/240V kW 2.2 2.5 3.5 4.5 2.5 3.5 4.5 5.5<br />

380/400V kW 3 4 5.5 7.5 4 5.5 7.5 11<br />

415V kW 3 4 5.5 7.5 4 5.5 7.5 11<br />

440V kW 3 4 5.5 7.5 4 5.5 7.5 11<br />

500V kW 3 4 7.5 7.5 4 7.5 7.5 15<br />

690V kW 3 4 7.5 7.5 4 7.5 7.5 15<br />

1000V kW - - - - - - - -<br />

According to IEC60947-4-1<br />

Rated making capacity AC-3 70 90 120 180 90 120 180 220<br />

Rated breaking capacity AC-3 56 72 96 144 72 96 144 176<br />

Electrical life for Ie/AC-3 Max<br />

in millions of operating cycles 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5<br />

Maximum operating rate<br />

in operating cycles per hour 1800 1800 1800 1800 1800 1800 1800 1800<br />

Devices usable in the starter combination<br />

<strong>Contactor</strong>s<br />

with AC or DC control coil MC-6a MC-9a MC-12a MC-18a MC-9b MC-12b MC-18b MC-22b<br />

with coil in common use for AC and DC - - - - - - - -<br />

Thermal <strong>Overload</strong> Relays<br />

Class 10A Differential type MT-12/3K MT-32/3K<br />

Non-differential type MT-12/3H MT-32/3H<br />

Non-differential type(2-heater) MT-12/2H MT-32/2H<br />

Class 20 Differential type MT-12/3D MT-32/3D<br />

Setting range A 0.1~18A 0.1~40A<br />

52


40AF 65AF 100AF<br />

MS-32a MS-40a MS-50a MS-65a MS-75a MS-85a MS-100a<br />

3 3 3<br />

690V 690V 690V<br />

IP20 IP20 IP20<br />

50 60 70 100 110 135 160<br />

32 40 55 65 75 85 105<br />

32 40 50 65 75 85 105<br />

32 40 50 65 75 85 105<br />

32 40 50 65 75 85 105<br />

28 32 43 60 64 75 85<br />

20 23 28 35 42 45 65<br />

17 17 23 23 28 28 28<br />

7.5 11 15 18.5 22 25 30<br />

15 18.5 22 30 37 45 55<br />

15 18.5 22 30 37 45 55<br />

15 18.5 22 30 37 45 55<br />

18.5 22 30 33 37 45 55<br />

18.5 22 30 33 37 45 55<br />

22 22 30 30 37 37 37<br />

320 400 500 650 750 850 1050<br />

256 320 400 520 600 650 840<br />

2 2 2 2 2 2 2<br />

1800 1800 1800 1800 1800 1800 1800<br />

MC-32a MC-40a MC-50a MC-65a MC-75a MC-85a MC-100a<br />

- - - - - - -<br />

MT-32/3K MT-63/3K MT-95/3K<br />

MT-32/3H MT-63/3H MT-95/3H<br />

MT-32/2H MT-63/2H MT-95/2H<br />

MT-32/3D MT-63/3D MT-95/3D<br />

0.1~40A 4~65A 7~100A<br />

53


Motor starters<br />

Description<br />

- Opened direct motor starter<br />

- 3-pole(NO) main contacts<br />

- Screw mountable<br />

- AC/DC common use control contactor used (from 225AF)<br />

- Additional accessories available<br />

- <strong>Overload</strong> relay is directly mounted to the contactor<br />

- Degree of protection: IP20<br />

Rating<br />

Starter type<br />

150AF<br />

225AF<br />

MS-130a MS-150a MS-185a MS-225a<br />

Number of poles 3 3<br />

Rated operational voltage (Ue) 690V 690V<br />

Degree of pollution (IEC60529) IP20 IP20<br />

Rated operational current Ie (θ≤40℃)<br />

AC-1 Ue max 690V A 160 210 230 275<br />

AC-3 200/240V A 130 150 185 225<br />

380/400V A 130 150 185 225<br />

415V A 130 150 185 225<br />

440V A 130 150 185 225<br />

500V A 90 100 180 200<br />

690V A 60 60 120 150<br />

` 1000V A 53 65 90 90<br />

Rated operational power (θ≤40℃)<br />

AC-3 200/240V kW 37 45 55 75<br />

380/400V kW 60 75 90 132<br />

415V kW 60 75 90 132<br />

440V kW 60 75 90 132<br />

500V kW 60 70 110 132<br />

690V kW 55 55 110 140<br />

1000V kW 75 90 132 132<br />

According to IEC60947-4-1<br />

Rated making capacity AC-3 1200 1500 1850 2250<br />

Rated breaking capacity AC-3 960 1200 1480 1800<br />

Electrical life for Ie/AC-3 Max<br />

in millions of operating cycles 1 1 1 1<br />

Maximum operating rate<br />

in operating cycles per hour 1200 1200 1200 1200<br />

Devices usable in the starter combination<br />

<strong>Contactor</strong>s<br />

with AC or DC control coil MC-130a MC-150a - -<br />

with coil in common use for AC and DC - - MC-185a MC-225a<br />

Thermal <strong>Overload</strong> Relays<br />

Class 10A Differential type MT-150/3K MT-225/3K<br />

Non-differential type MT-150/3H MT-225/3H<br />

Non-differential type(2-heater) MT-150/2H MT-225/2H<br />

Class 20 Differential type MT-150/3D MT-225/3D<br />

Setting range A 34~150A 65~240A<br />

54


400AF<br />

800AF<br />

MS-265a MS-330a MS-400a MS-500a MS-630a MS-800a<br />

3 3<br />

690V<br />

690V<br />

IP20<br />

IP20<br />

300 350 450 580 660 900<br />

265 330 400 500 630 800<br />

265 330 400 500 630 800<br />

265 330 400 500 630 800<br />

265 330 400 500 630 800<br />

225 250 350 400 500 720<br />

185 220 300 380 420 630<br />

105 105 105 220 220 220<br />

80 90 125 147 190 220<br />

147 160 200 265 330 440<br />

147 160 200 265 330 440<br />

147 160 200 265 330 440<br />

147 160 225 265 330 500<br />

160 200 250 300 400 500<br />

147 147 147 280 280 280<br />

2650 3300 4000 5000 6300 8000<br />

2120 2640 3200 4000 5040 6400<br />

1 1 0.5 0.5 0.5 0.5<br />

1200 1200 1200 1200 1200 1200<br />

- - - - - -<br />

MC-265a MC-330a MC-400a MC-500a MC-630a MC-800a<br />

MT-400/3K<br />

MT-800/3K<br />

MT-400/3H<br />

MT-800/3H<br />

MT-400/2H<br />

MT-800/2H<br />

MT-400/3D<br />

MT-800/3D<br />

85~400A 200~800A<br />

55


Reversing contactors<br />

Description<br />

Circuit diagram<br />

- Two AC or DC control contactors are interlocked mechanically<br />

and electrically<br />

- 3-pole(NO) main contact in each contactor<br />

- Finger proof design<br />

- DIN rail or screw mountable<br />

- Front/side mountable accessories available<br />

- <strong>Overload</strong> relay can be directly mounted to the contactor if necessary<br />

- Please use interval time of over 25ms<br />

- Degree of protection: IP20<br />

A1<br />

A1<br />

A2<br />

A2<br />

R/1/L1 S/3/L2 T/5/L3<br />

U/2/T1 V/4/T2 W/6/T3<br />

R/1/L1 S/3/L2 T/5/L3<br />

111NC<br />

121NC<br />

A1<br />

112NC<br />

A1<br />

122NC<br />

U/2/T1 V/4/T2 W/6/T3<br />

A2<br />

A2<br />

MC-40a/R<br />

MC-65a/R<br />

MC-100a/R<br />

Rating<br />

Current<br />

AC-3 duty<br />

(AC3)<br />

Weight<br />

Type 200 ~ 380 ~<br />

240V 400V<br />

415V 440V 500V 690V 1000V 440V (AC control)<br />

kW kW kW kW kW kW kW A<br />

MC-6a/R 2.2 3 3 3 3 3 - 7 0.63kg<br />

MC-9a/R 2.5 4 4 4 4 4 - 9 0.63kg<br />

MC-12a/R 3.5 5.5 5.5 5.5 7.5 7.5 - 12 0.63kg<br />

MC-18a/R 4.5 7.5 7.5 7.5 7.5 7.5 - 18 0.63kg<br />

MC-9b/R 2.5 4 4 4 4 4 - 9 0.75kg<br />

MC-12b/R 3.5 5.5 5.5 5.5 7.5 7.5 - 12 0.75kg<br />

MC-18b/R 4.5 7.5 7.5 7.5 7.5 7.5 - 18 0.75kg<br />

MC-22b/R 5.5 11 11 11 15 15 - 22 0.75kg<br />

MC-32a/R 7.5 18.5 18.5 18.5 22 22 22 32 0.95kg<br />

MC-40a/R 11 18.5 18.5 18.5 22 22 22 40 0.95kg<br />

MC-50a/R 15 22 22 22 30 30 30 50 1.7kg<br />

MC-65a/R 18.5 30 30 30 33 33 30 65 1.7kg<br />

MC-75a/R 22 37 37 37 37 37 37 75 3.3kg<br />

MC-85a/R 25 45 45 45 45 45 37 85 3.3kg<br />

MC-100a/R 30 55 55 55 55 55 37 105 3.3kg<br />

Coil voltage<br />

AC<br />

50Hz 24, 32, 42, 48, 80, 100, 110, 220, 230, 240, 380, 400, 500, 550V<br />

60Hz 24, 48, 100, 110, 120, 200, 208, 220, 230, 240, 277, 380, 480, 600V<br />

DC DC 12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250V<br />

Certification<br />

•CE(IEC)<br />

•UL508<br />

•CCC<br />

56


Description<br />

- 3-pole main contact<br />

- Mechanically interlocked<br />

- AC/DC common use coil built (from MC-185a/R)<br />

- Wide coil operation voltage<br />

- Screw mountable<br />

- 4NO4NC Auxiliary contacts built-in<br />

- Top/side mountable accessories available<br />

- Please use interval time of over 50ms<br />

- Degree of protection: IP20<br />

Rating<br />

Type<br />

200 ~ 380 ~<br />

240V 400V<br />

Current<br />

AC-3 duty<br />

(AC3)<br />

415V 440V 500V 690V 1000V 440V<br />

Weight<br />

(AC control)<br />

kW kW kW kW kW kW kW A<br />

MC-130a/R 37 60 60 60 60 55 75 130 4.3kg<br />

MC-150a/R 45 75 75 75 75 55 75 150 4.3kg<br />

MC-185a/R 55 90 90 90 110 110 132 185 13kg<br />

MC-225a/R 75 132 132 132 132 140 132 225 13kg<br />

MC-265a/R 80 147 147 147 147 160 147 265 21.4kg<br />

MC-330a/R 90 160 160 160 160 200 147 330 21.4kg<br />

MC-400a/R 125 200 200 200 225 250 147 400 21.4kg<br />

MC-500a/R 147 265 265 265 265 300 280 500 60kg<br />

MC-630a/R 190 330 330 330 330 400 280 630 60kg<br />

MC-800a/R 220 440 440 440 440 500 280 800 60kg<br />

Coil voltage<br />

For MC130a/R and MC-150a/R<br />

AC 50/60Hz 24, 48, 100~240, 110~120, 220~240, 300, 380~440, 500V<br />

DC DC 24, 48, 70~110, 100~220, 110, 220V<br />

For MC-185a/R ~ MC-800a/R<br />

- 24, 48, 100/200, 300, 400, 500V for types MC-185a/R, 225a/R<br />

- 100/200, 300, 400, 500V for types MC-265a/R, 330a/R, 400a/R<br />

- 100, 200, 300, 400, 500V for types MC-500a/R, 600a/R, 800a/R<br />

Nominal(ordering) voltage AC 50/60Hz DC<br />

24V 24 - 25V 24V<br />

48V 48 - 50V 48V<br />

100V 100 - 127V 100 - 110V<br />

200V 200 - 240V 200 - 220V<br />

100/200V 100 - 240V 100 - 220V<br />

300V 265 - 347V -<br />

400V 380 - 450V -<br />

500V 440 - 575V -<br />

57


LED voltage monitoring contactor<br />

Description<br />

- Real time observe coil voltage without additional equipments for protect coil burn out due to<br />

the under and over voltage<br />

Yellow LED: U/V<br />

(Under Voltage)<br />

Green LED: R/V<br />

(Rating Voltage)<br />

Red LED: O/V<br />

(Over Voltage)<br />

L/V<br />

L/V<br />

L/V R/V R/V R/V O/V O/V O/V<br />

L/V<br />

L/V<br />

L/V<br />

R/V<br />

R/V<br />

R/V<br />

O/V<br />

O/V<br />

O/VL/VL/VL/V<br />

R/V<br />

R/V<br />

R/V<br />

O/V<br />

O/V<br />

O/V<br />

Coil voltage<br />

LED indicate statue<br />

Type Coil voltage Under Voltage Rating Voltage Over Voltage<br />

(Yellow) (Green) (Red)<br />

110V ~80V 80~130V 130V~<br />

MC-130a, MC 150a 220V ~160V 160~260V 260V~<br />

400V ~330V 330~480V 280V~<br />

110V ~80V 80~130V 130V~<br />

MC-185a, MC-225a 220V ~160V 160~260V 260V~<br />

400V ~330V 330~480V 280V~<br />

MC-265a, MC-330a,<br />

110V ~80V 80~130V 130V~<br />

MC-400a<br />

220V ~160V 160~260V 260V~<br />

400V ~330V 330~480V 280V~<br />

MC-500a, MC-630a, 110V ~80V 80~130V 130V~<br />

MC-800a 220V ~160V 160~260V 260V~<br />

* The accuracy of LED indicate statue is ±5%<br />

58


<strong>Contactor</strong> relays<br />

Description<br />

- 4,6,8 pole units<br />

- AC/DC control voltage<br />

- 16A continuous current, Ith<br />

- DIN rail or screw mountable<br />

- Degree of protection: IP20<br />

Selection<br />

Poles<br />

Composition<br />

Types<br />

Remarks<br />

4 Pole 4NO<br />

3NO1NC<br />

2NO2NC<br />

1NO3NC<br />

4NC<br />

MR-4<br />

Additional auxiliary contacts can be<br />

mounted on the relays.<br />

MR-4<br />

6 Pole 6NO<br />

5NO1NC<br />

4NO2NC<br />

3NO3NC<br />

2NO4NC<br />

MR-6<br />

UA-2 is mounted on the MR-6.<br />

8 Pole 8NO<br />

7NO1NC<br />

6NO2NC<br />

5NO3NC<br />

4NO4NC<br />

MR-8<br />

UA-4 is mounted on the MR-8.<br />

MR-6<br />

MR-8<br />

Ratings<br />

Rated insulation voltage (Ui) AC 690V<br />

Continuous current (Ith)<br />

16A<br />

Operating cycle<br />

1800 operations/hour<br />

Endurance Mechanical life time 10 mil. Operations<br />

Electrical life time 0.25 mil. Operations<br />

Type MR-4 MR-6 MR-8<br />

AC-15 Rated current 120V 6 6 6<br />

(A) 240V 3 3 3<br />

380V 1.9 1.9 1.9<br />

480V 1.5 1.5 1.5<br />

500V 1.4 1.4 1.4<br />

600V 1.2 1.2 1.2<br />

MR-4 MR-4 UA-2 MR-4 UA-4<br />

DC-13 Rated current 125V 1.1 1.1 0.55 1.1 0.55<br />

(A) 250V 0.55 0.55 0.27 0.55 0.27<br />

400V 0.31 0.31 0.15 0.31 0.15<br />

500V 0.27 0.27 0.13 0.27 0.13<br />

600V 0.2 0.2 0.1 0.2 0.1<br />

Minimum rated through current<br />

DC 24V 10mA<br />

Coil voltage<br />

AC<br />

50Hz 24, 32, 42, 48, 65, 80, 100, 110, 120, 220, 230, 240, 380, 400, 500, 550V<br />

60Hz<br />

DC DC<br />

Voltage limit 85%~110%<br />

24, 48, 110, 120, 200, 208, 220, 230, 240, 277, 380, 480, 600V<br />

12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250V<br />

Note) See page 22, 23 for details.<br />

* Please be cautious for wiring control power cable, especially “ + ” (Positive) and “ - ” (Negative) polarity should be correctly considered.<br />

59


Latching contactors<br />

9<br />

~<br />

150<br />

Description<br />

- 3-pole main contact<br />

- Mechanically latched<br />

- Finger proof design<br />

- DIN rail or screw mountable<br />

- Side mountable accessories available<br />

- Direct mountable overload relays available<br />

Circuit diagram<br />

MC-6a/L~150a/L<br />

E1<br />

A1<br />

E2<br />

A2<br />

Rating<br />

AC3 ratings<br />

Devices combined<br />

<strong>Contactor</strong> 200/240V 380/440V 500/550V 690V 1000V<br />

Durability Operational Excitation<br />

Type<br />

kW kW kW kW kW (Machanical) time time<br />

MC-6a/L 2.2 3 3 3 -<br />

MC-9a/L 2.5 4 4 4 -<br />

MC-12a/L 3.5 5.5 7.5 7.5 -<br />

MC-18a/L 4.5 7.5 7.5 7.5 -<br />

More than<br />

MC-9b/L 2.5 4 4 4 -<br />

50ms<br />

MC-12b/L 3.5 5.5 7.5 7.5 -<br />

Less 30ms<br />

ML-65 0.5 mil.<br />

(AC)<br />

MC-18b/L 4.5 7.5 7.5 7.5 -<br />

(AC)<br />

MC-22b/L 5.5 11 15 15 -<br />

More than<br />

MC-32a/L 11 18.5 22 22 22<br />

Less 50ms<br />

70ms<br />

MC-40a/L 11 18.5 22 22 22<br />

(DC)<br />

(DC)<br />

MC-50a/L 15 22 30 30 30<br />

MC-65a/L 18.5 30 33 33 30<br />

MC-75a/L 22 37 37 37 37<br />

MC-85a/L 25 45 45 45 37<br />

MC-100a/L 30 55 55 45 37 ML-150 2.5 mil.<br />

MC-130a/L 37 60 60 55 75<br />

More than<br />

Less 100ms<br />

MC-150a/L 45 75 75 55 75<br />

130ms<br />

Coil voltage<br />

AC 50/60Hz 24, 48, 100, 110, 120, 200, 220, 230, 240, 380, 400, 415, 440V<br />

DC DC 24, 48, 110V<br />

Certification<br />

•CE(IEC)<br />

•UL508<br />

60


Accessories<br />

Surge unit, US<br />

connecting to coil<br />

terminals<br />

▶84 page<br />

Auxiliary contact unit, UA-1<br />

side mount, 1NO+1NC<br />

▶77 page<br />

Auxiliary contact unit, UA-1<br />

side mount, 1NO+1NC<br />

▶77 page<br />

* It is not possible to attach “ UA-1 ”<br />

on the right side of product for<br />

Range MC-9b~22b.<br />

<strong>Overload</strong> relay<br />

MT-12 ~ MT-150<br />

▶90 page<br />

61


Latching contactors<br />

185<br />

~<br />

400<br />

Description<br />

- 3-pole main contact<br />

- Mechanically interlocked<br />

- AC/DC common use coil built<br />

- Wide coil operation voltage<br />

- Screw mountable<br />

- 1NO+2NC Auxiliary contacts built-in as standard<br />

- Top/side mountable accessories available<br />

Circuit diagram<br />

Open<br />

Close<br />

Rating<br />

AC3 ratings<br />

Auxiliary<br />

<strong>Contactor</strong> 200 ~ 380 ~ 500 ~<br />

690V 1000V<br />

contact<br />

240V 440V 550V (standard)<br />

MC-185a/L<br />

55kW 90kW 110kW 110kW 132kW<br />

185A 185A 180A 120A 90A<br />

MC-225a/L<br />

75kW 132kW 132kW 140kW 132kW<br />

225A 225A 200A 150A 90A<br />

MC-265a/L<br />

80kW 147kW 147kW 160kW 147kW<br />

2NO2NC<br />

265A 265A 225A 185A 105A<br />

MC-330a/L<br />

90kW 160kW 160kW 200kW 147kW<br />

330A 330A 280A 225A 105A<br />

MC-400a/L<br />

125kW 200kW 225kW 250kW 147kW<br />

400A 400A 350A 300A 105A<br />

Coil voltage<br />

Nominal(ordering) voltage<br />

100V<br />

200V<br />

Operational voltage Operation frequency<br />

AC100~127V 600 operations/hour<br />

DC100~125V 300 operations/hour<br />

AC200~240V 600 operations/hour<br />

DC200~220V 300 operations/hour<br />

62


Accessories<br />

AP220~400<br />

Terminal cover<br />

▶81 page<br />

AU-100, 100E<br />

Auxiliary contact unit<br />

side mount, 1NO+1NC<br />

▶78 page<br />

AI-180<br />

Insulation barrier<br />

▶81 page<br />

<strong>Overload</strong> relay<br />

MT-225H ~ MT-400H<br />

MT-225/3H ~ MT-400/3H<br />

MT-225/3K ~ MT-400/3K<br />

▶ 93 page<br />

63


4-pole <strong>Contactor</strong>s (18AF)<br />

Description<br />

- 4-pole main contact<br />

- Finger proof design<br />

- DIN rail or screw mountable<br />

- Small physical size: 44 mm wide<br />

- Auxiliary contacts are optional<br />

- Front/side mountable accessories<br />

- Direct mountable overload relays available<br />

- Degree of protection: IP20<br />

MC-18a/4<br />

2pole for DC contact<br />

3pole for DC contact<br />

4pole for DC contact<br />

Rating<br />

<strong>Contactor</strong> type<br />

MC-6a/4 MC-9a/4 MC-12a/4 MC-18a/4<br />

kW A kW A kW A kW A<br />

AC duty AC1 200/240V 9 25 9 25 9 25 15 40<br />

380/440V 17 25 17 25 17 25 27 40<br />

500/550V 21 25 21 25 21 25 35 40<br />

690V 27 25 27 25 27 25 44 40<br />

AC3 200/240V 2.2 9 2.5 11 3.5 13 4.5 18<br />

380/440V 3 7 4 9 5.5 12 7.5 18<br />

Ith - 25 - 25 - 25 - 40<br />

DC1 duty 2-pole 110V - 12 - 12 - 12 - 12<br />

(L/R=1ms) in series 220V - 8 - 8 - 8 - 8<br />

3-pole 110V - 15 - 15 - 15 - 15<br />

in series 220V - 10 - 10 - 10 - 10<br />

4-pole 110V - 17 - 17 - 17 - 17<br />

in series 220V - 12 - 12 - 12 - 12<br />

UL rating hp A hp A hp A hp A<br />

220/240V 3 - 3 - 5 - 7.5 -<br />

440/480V 5 - 5 - 7.5 - 10 -<br />

550/600V 7.5 - 7.5 - 10 - 15 -<br />

Ith - 25 - 25 - 25 - 32<br />

Conductor size (solid, stranded) AWG 18~10 18~10 16~10 16~8<br />

(the max. number of conducts: 2) mm² 1.5~4 1.5~10 1.5~10 1~4<br />

Conductor type<br />

65/75℃ Cu-wire only<br />

Coil voltage<br />

50Hz<br />

AC 60Hz<br />

50/60Hz<br />

DC DC<br />

24, 32, 42, 48, 80, 100, 110, 220, 230, 240, 380, 400, 500, 550V<br />

24, 48, 100, 110, 120, 200, 208, 220, 230, 240, 277, 380, 480, 600V<br />

24, 48, 100, 110, 120, 200, 220, 230, 240, 380, 415, 440, 500, 550V<br />

12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250V<br />

Certification<br />

•CE(IEC)<br />

•UL508<br />

•CCC<br />

64


Accessories<br />

Delayed opening<br />

device, AD-9<br />

▶81 page<br />

Surge unit, US<br />

connecting to coil<br />

terminals<br />

▶84 page<br />

Interlock unit, UR<br />

side mount<br />

▶82 page<br />

Auxiliary contact unit, UA-1<br />

side mount, 1NO+1NC<br />

▶77 page<br />

Auxiliary contact unit, UA-4<br />

front mount, 4P<br />

▶77 page<br />

Auxiliary contact unit, UA-2<br />

front mount, 2P<br />

▶77 page<br />

Safety cover, A7<br />

▶87 page<br />

65


4-pole <strong>Contactor</strong>s (22, 40AF)<br />

Description<br />

- 4-pole main contact<br />

- Finger proof design<br />

- DIN rail or screw mountable<br />

- Auxiliary contacts are optional<br />

- Front/side mountable accessories<br />

- Direct mountable overload relays available<br />

- Degree of protection: IP20<br />

MC-22a/4<br />

MC-40a/4<br />

2pole for DC contact<br />

Rating<br />

<strong>Contactor</strong> type<br />

MC-22a/4 MC-32a/4 MC-40a/4<br />

kW A kW A kW A<br />

AC duty AC1 200/240V 15 40 18 50 22 60<br />

380/440V 27 40 35 50 42 60<br />

500/550V 35 40 43 50 52 60<br />

690V 44 40 55 50 66 60<br />

AC3 200/240V 5.5 22 7.5 32 11 40<br />

380/440V 11 22 15 32 18.5 40<br />

Ith - 40 - 50 - 60<br />

DC1 duty 2-pole 110V - 15 - 25 - 25<br />

(L/R=1ms) in series 220V - 10 - 12 - 12<br />

3-pole 110V - 20 - 27 - 27<br />

in series 220V - 12 - 15 - 15<br />

4-pole 110V - 20 - 30 - 30<br />

in series 220V - 15 - 22 - 22<br />

UL rating hp A hp A hp A<br />

220/240V 7.5 - 10 - 10 -<br />

440/480V 10 - 20 - 25 -<br />

550/600V 15 - 20 - 25 -<br />

Ith - 32 - 45 - 50<br />

Conductor size (solid, stranded) AWG 12~8 10~6 8~6<br />

(the max. number of conducts: 2) mm² 2.5~10 4~16 10~16<br />

Conductor type<br />

65/75℃ Cu-wire only<br />

66<br />

3pole for DC contact<br />

4pole for DC contact<br />

Coil voltage<br />

50Hz 24, 36, 42, 48, 65, 80, 100, 110, 220, 230, 240, 380, 400, 415, 440, 500, 550, 240(wide)V<br />

AC 60Hz 24, 48, 110, 208, 220, 240, 277, 380, 440, 480, 600V<br />

50/60Hz 24, 48, 100, 110, 120, 200, 220, 230, 240, 380, 400, 415, 440, 500, 550V<br />

DC DC 12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250V<br />

Certification<br />

•CE(IEC)<br />

•UL508<br />

•CCC


Accessories<br />

Delayed opening<br />

device, AD-9<br />

▶81 page<br />

Surge unit, AS<br />

connecting to coil<br />

terminals<br />

▶84 page<br />

Interlock unit, AR-9 *<br />

side mount<br />

Auxiliary contact unit, AU-1 *<br />

side mount, 1NO+1NC<br />

Auxiliary contact unit, UA-4<br />

front mount, 4P<br />

▶77 page<br />

Auxiliary contact unit, UA-2<br />

front mount, 2P<br />

▶77 page<br />

Safety cover, A7<br />

▶87 page<br />

* AU-1 and AR-9 are discontinued item. Please contact us in case of purchasing.<br />

67


4-pole <strong>Contactor</strong>s (85AF)<br />

Description<br />

- 4-pole main contact<br />

- Finger proof design<br />

- DIN rail or screw mountable<br />

- Auxiliary contacts are optional<br />

- Front/side mountable accessories<br />

- Direct mountable overload relays available<br />

- Degree of protection: IP20<br />

MC-85a/4<br />

2pole for DC contact<br />

3pole for DC contact<br />

4pole for DC contact<br />

Rating<br />

<strong>Contactor</strong> type<br />

MC-50a/4 MC-65a/4 MC-75a/4 MC-85a/4<br />

kW A kW A kW A kW A<br />

AC duty AC1 200/240V 30 80 37 100 41 110 51 135<br />

380/440V 56 80 70 100 76 110 95 135<br />

500/550V 70 80 88 100 97 110 120 135<br />

690V 88 80 110 100 120 110 150 135<br />

AC3 200/240V 15 55 18.5 65 22 75 25 85<br />

380/440V 22 50 30 65 37 75 45 85<br />

Ith - 80 - 100 - 110 - 135<br />

DC1 duty 2-pole 110V - 35 - 35 - 50 - 50<br />

(L/R=1ms) in series 220V - 15 - 15 - 35 - 35<br />

3-pole 110V - 40 - 40 - 60 - 60<br />

in series 220V - 30 - 30 - 40 - 40<br />

4-pole 110V - 50 - 50 - 70 - 70<br />

in series 220V - 35 - 35 - 50 - 50<br />

UL rating hp A hp A hp A hp A<br />

220/240V 15 - 20 - 25 - 30 -<br />

440/480V 30 - 40 - 50 - 50 -<br />

550/600V 30 - 40 - 50 - 50 -<br />

Ith - 70 - 80 - 90 - 100<br />

Conductor size (solid, stranded) AWG 8~4 6~3 4~2 4~1<br />

(the max. number of conducts: 2) mm² 10~25 16~35 25~35 25~50<br />

Conductor type<br />

65/75℃ Cu-wire only<br />

Coil voltage<br />

50Hz<br />

AC 60Hz<br />

50/60Hz<br />

DC DC<br />

24, 48, 100, 110, 200, 220, 230, 240, 380, 400, 415, 440, 500, 550V, 240(wide)V<br />

24, 48, 110, 120, 208, 220, 240, 277, 380, 440, 480, 600V<br />

24, 48, 110, 120, 220, 230, 240, 380, 400, 415, 440, 500, 550V<br />

12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250V<br />

Certification<br />

•CE(IEC)<br />

•UL508<br />

•CCC<br />

68


Accessories<br />

Delayed opening<br />

device, AD-50<br />

▶81 page<br />

Surge unit, AS<br />

connecting to coil<br />

terminals<br />

▶84 page<br />

Auxiliary contact unit, AU-1 *<br />

side mount, 1NO+1NC<br />

Interlock unit, AR-9 *<br />

side mount<br />

Auxiliary contact unit, UA-4<br />

front mount, 4P<br />

▶77 page<br />

Auxiliary contact unit, UA-2<br />

front mount, 2P<br />

▶77 page<br />

Safety cover, A7<br />

▶87 page<br />

* AU-1 and AR-9 are discontinued item. Please contact us in case of purchasing.<br />

69


4-pole <strong>Contactor</strong>s (225AF)<br />

Description<br />

- 4-pole main contact<br />

- AC/DC common use coil built<br />

- Wide coil operation voltage<br />

- Screw mountable<br />

- 2NO+2NC Auxiliary contacts built-in as standard<br />

- Side mountable accessories<br />

- Direct mountable overload relays available<br />

- Degree of protection: IP20<br />

MC-225a/4<br />

2pole for DC contact<br />

3pole for DC contact<br />

4-pole in series<br />

Rating<br />

<strong>Contactor</strong> type<br />

MC-100a/4 MC-130a/4 MC-150a/4 MC-185a/4 MC-225a/4<br />

kW A kW A kW A kW A kW A<br />

AC duty AC1 200/240V 57 150 60 155 76 200 87 230 100 260<br />

380/440V 106 150 110 155 142 200 165 230 185 260<br />

500/550V 132 150 137 155 180 200 205 230 230 260<br />

690V 165 150 170 155 225 200 255 230 290 260<br />

AC3 200/240V 30 105 37 125 45 150 55 185 75 225<br />

380/440V 55 105 60 120 75 150 90 185 132 225<br />

Ith - 200 - 250 - 275 - 300 - 350<br />

DC1 duty 2-pole 110V - 80 - 80 - 100 - 150 - 150<br />

(L/R=1ms) in series 220V - 50 - 50 - 100 - 150 - 150<br />

3-pole 110V - 90 - 90 - 150 - 185 - 225<br />

in series 220V - 60 - 60 - 150 - 185 - 225<br />

4-pole 110V - 100 - 100 - 150 - 185 - 225<br />

in series 220V - 80 - 80 - 150 - 185 - 225<br />

UL rating hp A hp A hp A hp A hp A<br />

220/240V 30 - 40 - 50 - 60 - 75 -<br />

440/480V 60 - 75 - 100 - 125 - 150 -<br />

550/600V 60 - 75 - 100 - 125 - 150 -<br />

Ith - 160 - 160 - 210 - 230 - 275<br />

Conductor size (solid, stranded) AWG 6~00 3~00 3~4/0 1~4/0 0~300<br />

(the max. number of conducts: 2) mm² 16~70 35~70 35~95 50~95 50~150<br />

Conductor type<br />

75°C Cu stranded wire<br />

Coil voltage, AC/DC common<br />

Nominal(ordering) voltage AC 50/60Hz DC<br />

24V 24 - 25V 24V<br />

48V 48 - 50V 48V<br />

100/200V 100 - 240V 100 - 220V<br />

300V 265 - 347V -<br />

400V 380 - 450V -<br />

500V 440 - 575V -<br />

Certification<br />

•CE(IEC)<br />

•UL508<br />

•CCC<br />

70


Accessories<br />

AD-100<br />

Delayed opening device<br />

▶81 page<br />

Safety cover, A7<br />

▶87 page<br />

AU-100, 100E<br />

Auxiliary contact unit<br />

side mount, 1NO+1NC<br />

▶78 page<br />

AP220/4<br />

Terminal cover<br />

▶81 page<br />

AR-180<br />

Interlock unit<br />

side mount<br />

▶83 page<br />

AI-180<br />

Insulation barrier<br />

▶81 page<br />

71


4-pole <strong>Contactor</strong>s (400AF)<br />

Description<br />

- 4-pole main contact<br />

- AC/DC common use coil built<br />

- Wide coil operation voltage<br />

- Screw mountable<br />

- 2NO+2NC Auxiliary contacts built-in as standard<br />

- Side mountable accessories<br />

- Degree of protection: IP20<br />

MC-400a/4<br />

2pole for DC contact<br />

3pole for DC contact<br />

4pole for DC contact<br />

Rating<br />

<strong>Contactor</strong> type<br />

MC-265a/4 MC-330a/4 MC-400a/4<br />

kW A kW A kW A<br />

AC duty AC1 200/240V 115 300 135 350 160 420<br />

380/440V 215 300 250 350 300 420<br />

500/550V 265 300 315 350 375 420<br />

690V 335 300 390 350 470 420<br />

AC3 200/240V 80 265 90 330 125 400<br />

380/440V 147 265 160 330 200 400<br />

Ith - 400 - 500 - 520<br />

DC1 duty 2-pole 110V - 200 - 200 - 200<br />

(L/R=1ms) in series 220V - 200 - 200 - 200<br />

3-pole 110V - 265 - 330 - 400<br />

in series 220V - 265 - 330 - 400<br />

4-pole 110V - 265 - 330 - 400<br />

in series 220V - 265 - 330 - 400<br />

UL rating hp A hp A hp A<br />

220/240V 100 - 125 - 150 -<br />

440/480V 200 - 250 - 300 -<br />

550/600V 200 - 250 - 300 -<br />

Ith - 300 - 350 - 450<br />

Conductor size (solid, stranded) AWG 3/0~500 4/0~500 350~700<br />

(the max. number of conducts: 2) mm² 95~240 95~240 185~370<br />

Conductor type<br />

75°C Cu stranded wire<br />

Coil voltage, AC/DC common<br />

Nominal(ordering) voltage AC 50/60Hz DC<br />

100/200V 100 - 240V 100 - 220V<br />

300V 265 - 347V -<br />

400V 380 - 450V -<br />

500V 440 - 575V -<br />

Certification<br />

•CE(IEC)<br />

•UL508<br />

•CCC<br />

72


Accessories<br />

AD-300<br />

Delayed opening device<br />

▶81 page<br />

Safety cover, A7<br />

▶87 page<br />

AU-100, 100E<br />

Auxiliary contact unit<br />

side mount, 1NO+1NC<br />

▶78 page<br />

AP-400/4<br />

Terminal cover<br />

▶81 page<br />

AR-180<br />

Interlock unit<br />

side mount<br />

▶83 page<br />

AI-180<br />

Insulation barrier<br />

▶81 page<br />

73


4-pole <strong>Contactor</strong>s (800AF)<br />

Description<br />

- 4-pole main contact<br />

- AC/DC common use coil built<br />

- Wide coil operation voltage<br />

- Screw mountable<br />

- 2NO+2NC Auxiliary contacts built-in as standard<br />

- Side mountable accessories<br />

- Degree of protection: IP20<br />

MC-800a/4<br />

2pole for DC contact<br />

3pole for DC contact<br />

Rating<br />

<strong>Contactor</strong> type<br />

MC-500a/4 MC-630a/4 MC-800a/4<br />

kW A kW A kW A<br />

AC duty AC1 200/240V 245 630 255 660 310 800<br />

380/440V 450 630 470 660 570 800<br />

500/550V 560 630 590 660 710 800<br />

690V 710 630 740 660 900 800<br />

AC3 200/240V 147 500 190 630 220 800<br />

380/440V 265 500 330 630 440 800<br />

Ith - 700 - 900 - 1050<br />

DC1 duty 2-pole 110V - 500 - 630 - 630<br />

(L/R=1ms) 220V - 500 - 630 - 630<br />

3-pole 110V - 500 - 630 - 800<br />

220V - 500 - 630 - 800<br />

4-pole 110V - 500 - 630 - 800<br />

220V - 500 - 630 - 800<br />

UL rating hp A hp A hp A<br />

220/240V 200 - 250 - 300 -<br />

440/480V 400 - 500 - 600 -<br />

550/600V 400 - 500 - 600 -<br />

Ith - 580 - 660 - 900<br />

Conductor size (solid, stranded) AWG 350~800 600~2000 1700~Busbar<br />

(the max. number of conducts: 2) mm² 185~480 - -<br />

Conductor type<br />

75°C Cu stranded wire<br />

4pole for DC contact<br />

Coil voltage, AC/DC common<br />

Nominal(ordering) voltage AC 50/60Hz DC<br />

100V 100 - 127V 100 - 110V<br />

200V 200 - 240V 200 - 220V<br />

300V 265 - 347V -<br />

400V 380 - 450V -<br />

500V 440 - 575V -<br />

Certification<br />

•CE(IEC)<br />

•UL508<br />

•CCC<br />

74


Accessories<br />

AD-600<br />

Delayed opening device<br />

▶81 page<br />

Safety cover, A7<br />

▶87 page<br />

AU-100, 100E<br />

Auxiliary contact unit<br />

side mount, 1NO+1NC<br />

▶78 page<br />

AP-800/4<br />

Terminal cover<br />

▶81 page<br />

AR-600<br />

Interlock unit<br />

▶83 page<br />

AI-600<br />

Insulation barrier<br />

▶81 page<br />

75


Enclosed motor starters, Mold enclosure<br />

Description<br />

- Enclosed & full voltage type<br />

MW-bM: Plastic enclosure without buttons<br />

MW-bMB: Plastic enclosure with ON/OFF buttons<br />

- With differential or non-differential type thermal overload relay<br />

- <strong>Contactor</strong>s: 3 pole with AC coil<br />

- Screw mountable<br />

- Degree of protection: IP40<br />

Ratings<br />

AC3 Ratings Continuous Auxiliary Devices combined<br />

Type 220 ~ 380 ~ 500 ~<br />

current contact<br />

<strong>Overload</strong><br />

690<br />

<strong>Contactor</strong><br />

240V 440V 550V Ith (standard) relay<br />

2.5kW 4kW 4kW 4kW<br />

MW-9bM(B)<br />

25A<br />

MC-9b<br />

11A 9A 7A 6A<br />

3.5kW 5.5kW 7.5kW 7.5kW<br />

MW-12bM(B)<br />

25A<br />

MC-12b<br />

13A 12A 12A 9A<br />

MT-32<br />

1NO1NC<br />

4.5kW 7.5kW 7.5kW 7.5kW<br />

(0.1~22A)<br />

MW-18bM(B)<br />

40A<br />

MC-18b<br />

18A 18A 13A 9A<br />

5.5kW 11kW 15kW 15kW<br />

MW-22bM(B)<br />

40A<br />

MC-22b<br />

22A 22A 20A 18A<br />

<strong>Overload</strong> relay setting range, Amp.<br />

0.1 - 0.16<br />

0.16 - 0.25<br />

0.25 - 0.4<br />

0.4 - 0.63<br />

0.63 - 1<br />

1 - 1.6<br />

1.6 - 2.5<br />

2.5 - 4<br />

4 - 6<br />

MT-12 MT-32 MT-63 MT-95<br />

5 - 8<br />

6 - 9<br />

7 - 10<br />

9 - 13<br />

12 - 18<br />

0.1 - 0.16<br />

0.16 - 0.25<br />

0.25 - 0.4<br />

0.4 - 0.63<br />

0.63 - 1<br />

1 - 1.6<br />

1.6 - 2.5<br />

2.5 - 4<br />

4 - 6<br />

5 - 8<br />

6 - 9<br />

7 - 10<br />

9 - 13<br />

12 - 18<br />

16 - 22<br />

18 - 25<br />

22 - 32<br />

28 - 40<br />

4 - 6<br />

5 - 8<br />

6 - 9<br />

7 - 10<br />

9 - 13<br />

12 - 18<br />

16 - 22<br />

18 - 25<br />

24 - 36<br />

28 - 40<br />

34 - 50<br />

45 - 65<br />

7 - 10<br />

9 - 13<br />

12 - 18<br />

16 - 22<br />

18 - 25<br />

24 - 36<br />

28 - 40<br />

34 - 50<br />

45 - 65<br />

54 - 75<br />

63 - 85<br />

70 - 95<br />

80 - 100<br />

Internal device<br />

Coil voltage<br />

AC<br />

50Hz 24, 32, 42, 48, 80, 100, 110, 220, 230, 240, 380, 400, 500, 550V<br />

60Hz 24, 48, 100, 110, 120, 200, 208, 220, 230, 240, 277, 380, 480, 600V<br />

DC DC 12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250V<br />

Certification<br />

•CE(IEC)<br />

•UL508<br />

76


Enclosed motor starters, Steel enclosure<br />

Description<br />

- Full voltage type<br />

MW-a/MW-b: Steel enclosure without buttons<br />

MW-aB/MW-bB: Steel enclosure ON/OFF buttons<br />

- <strong>Contactor</strong>s: 3 pole with AC coil<br />

- <strong>Overload</strong> relayWith differential or non-differential type<br />

- Screw mountable<br />

- Degree of protection: IP40<br />

Ratings<br />

AC3 Ratings<br />

Devices combined<br />

Type 220 ~ 380 ~ 500 ~<br />

690V 1000V <strong>Contactor</strong><br />

<strong>Overload</strong><br />

240V 440V 550V relay<br />

MW-6a(B) 2.2kW 9A 3kW 7A 3kW 6A 3kW 4A - MC-6a<br />

MW-9a(B) 2.5kW 11A 4kW 9A 4kW 7A 4kW 5A - MC-9a MT-12<br />

MW-12a(B) 3.5kW 13A 5.5kW 12A 7.5kW 12A 7.5kW 9A - MC-12a (0.1~18A)<br />

MW-18a(B) 4.5kW 18A 7.5kW 18A 7.5kW 13A 7.5kW 9A - MC-18a<br />

MW-9b(B) 2.5kW 11A 4kW 9A 4kW 7A 4kW 6A - MC-9b<br />

MW-12b(B) 3.5kW 13A 5.5kW 12A 7.5kW 12A 7.5kW 9A - MC-12b MT-32<br />

MW-18b(B) 4.5kW 18A 7.5kW 18A 7.5kW 13A 7.5kW 9A - MC-18b (0.1~22A)<br />

MW-22b(B) 5.5kW 22A 11kW 22A 15kW 20A 15kW 18A - MC-22b<br />

MW-32a(B) 7.5kW 32A 15kW 32A 18.5kW 28A 18.5kW 20A 22kW 17A MC-32a MT-32<br />

MW-40a(B) 11kW 40A 18.5kW 40A 22kW 32A 22kW 23A 22kW 17A MC-40a (0.1~40A)<br />

MW-50a(B) 15kW 55A 22kW 50A 30kW 43A 30kW 28A 30kW 23A MC-50a MT-63<br />

MW-65a(B) 18.5kW 65A 30kW 65A 33kW 60A 33kW 35A 33kW 26A MC-65a (4~65A)<br />

MW-75a(B) 22kW 75A 37kW 75A 37kW 64A 37kW 42A 37kW 28A MC-75a<br />

MT-95<br />

MW-85a(B) 25kW 85A 45kW 85A 45kW 75A 45kW 45A 45kW 33A MC-85a<br />

(7~100A)<br />

MW-100a(B) 30kW 105A 55kW 105A 55kW 85A 55kW 65A 45kW 33A MC-100a<br />

Internal device<br />

<strong>Overload</strong> relay setting range, Amp.<br />

0.1 - 0.16<br />

0.16 - 0.25<br />

0.25 - 0.4<br />

0.4 - 0.63<br />

0.63 - 1<br />

1 - 1.6<br />

1.6 - 2.5<br />

2.5 - 4<br />

4 - 6<br />

MT-12 MT-32 MT-63 MT-95<br />

5 - 8<br />

6 - 9<br />

7 - 10<br />

9 - 13<br />

12 - 18<br />

0.1 - 0.16<br />

0.16 - 0.25<br />

0.25 - 0.4<br />

0.4 - 0.63<br />

0.63 - 1<br />

1 - 1.6<br />

1.6 - 2.5<br />

2.5 - 4<br />

4 - 6<br />

5 - 8<br />

6 - 9<br />

7 - 10<br />

9 - 13<br />

12 - 18<br />

16 - 22<br />

18 - 25<br />

22 - 32<br />

28 - 40<br />

4 - 6<br />

5 - 8<br />

6 - 9<br />

7 - 10<br />

9 - 13<br />

12 - 18<br />

16 - 22<br />

18 - 25<br />

24 - 36<br />

28 - 40<br />

34 - 50<br />

45 - 65<br />

7 - 10<br />

9 - 13<br />

12 - 18<br />

16 - 22<br />

18 - 25<br />

24 - 36<br />

28 - 40<br />

34 - 50<br />

45 - 65<br />

54 - 75<br />

63 - 85<br />

70 - 95<br />

80 - 100<br />

Coil voltage<br />

AC<br />

50Hz 24, 32, 42, 48, 80, 100, 110, 220, 230, 240, 380, 400, 500, 550V<br />

60Hz 24, 48, 100, 110, 120, 200, 208, 220, 230, 240, 277, 380, 480, 600V<br />

DC DC 12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250V<br />

Certification<br />

•CE(IEC)<br />

•UL508<br />

77


Capacitor contactors<br />

Description<br />

Capacitor unit(Pre-loading resistor) is connected to the terminals of the<br />

contactor to reduce the high inrush current exceeding 20×In.<br />

- AC or DC control coil on selection - 3-pole(NO) main contact - Finger proof design<br />

- DIN rail or screw mountable - IEC 60947-4-1 AC 6b<br />

Type<br />

MC-9b with<br />

AC-9<br />

MC-12b with<br />

AC-9<br />

MC-18b with<br />

AC-9<br />

MC-22b with<br />

AC-9<br />

MC-32a with<br />

AC-9<br />

MC-40a with<br />

AC-9<br />

MC-50a with<br />

AC-50<br />

MC-65a with<br />

AC-50<br />

MC-75a with<br />

AC-75<br />

MC-85a with<br />

AC-75<br />

MC-100a with<br />

AC-75<br />

Note) 1. When the switch is closed condenser must be discharged before<br />

recharged. (Maximum residual voltage at terminals ≤ 50V)<br />

2. To prevent short current, gG type fuse must be 1.5~2 times than<br />

rated current.<br />

Coil voltage<br />

Rating (kVar, A)<br />

220~240V 400~440V 500~550V 600~690V<br />

5kVar 9.7kVar 14kVar 16kVar<br />

13A 14A 16A 15A<br />

6.7kVar 12.5kVar 18kVar 18kVar<br />

18A 18A 21A 17A<br />

8.5kVar 16.7kVar 24kVar 26kVar<br />

22A 24A 28A 25A<br />

10kVar 18kVar 26kVar 30kVar<br />

26A 26A 30A 29A<br />

15kVar 25kVar 36kVar 40kVar<br />

39A 36A 42A 38A<br />

20kVar 33.3kVar 48kVar 53kVar<br />

52A 48A 55A 51A<br />

20kVar 40kVar 58kVar 65kVar<br />

52A 58A 67A 63A<br />

25kVar 45.7kVar 66kVar 73kVar<br />

66A 66A 76A 70A<br />

29.7kVar 54kVar 78kVar 85kVar<br />

78A 78A 90A 82A<br />

35kVar 60kVar 92kVar 100kVar<br />

92A 87A 106A 96A<br />

37kVar 62kVar 94kVar 105kVar<br />

97A 89A 109A 101A<br />

Type<br />

Ith<br />

MC-9b 25<br />

MC-12b 25<br />

MC-18b 40<br />

MC-22b 40<br />

MC-32a 50<br />

MC-40a 60<br />

MC-50a 70<br />

MC-65a 100<br />

MC-75a 110<br />

MC-85a 135<br />

MC-100a 160<br />

MC-130a 160<br />

MC-150a 210<br />

MC-185a 230<br />

MC-225a 275<br />

MC-265a 300<br />

MC-330a 350<br />

MC-400a 450<br />

MC-500a 580<br />

MC-630a 660<br />

MC-800a 900<br />

Rating (kVar, A)<br />

500~550V 600~690V<br />

4kVar 3.5kVar<br />

4.6A 3.4A<br />

4kVar 4kVar<br />

4.6A 3.8A<br />

5kVar 4.5kVar<br />

5.8A 4.3A<br />

8kVar 8kVar<br />

9.2A 7.7A<br />

17kVar 14kVar<br />

20A<br />

13A<br />

25kVar 18kVar<br />

29A<br />

17A<br />

30kVar 25kVar<br />

35A<br />

24A<br />

40kVar 35kVar<br />

45A<br />

34A<br />

50kVar 40kVar<br />

58A<br />

38A<br />

55kVar 45kVar<br />

64A<br />

43A<br />

60kVar 48kVar<br />

69A<br />

46A<br />

70kVar 60kVar<br />

81A<br />

58A<br />

90kVar 78kVar<br />

104A<br />

75A<br />

120kVar 100kVar<br />

139A<br />

96A<br />

130kVar 105kVar<br />

150A 101A<br />

140kVar 115kVar<br />

162A 111A<br />

185kVar 140kVar<br />

214A 135A<br />

195kVar 160kVar<br />

225A 154A<br />

330kVar 290kVar<br />

381A 279A<br />

340kVar 300kVar<br />

393A 289A<br />

370kVar 320kVar<br />

427A 308A<br />

AC<br />

50Hz 24, 32, 42, 48, 80, 100, 110, 220, 230, 240, 380, 400, 500, 550V<br />

60Hz 24, 48, 100, 110, 120, 200, 208, 220, 230, 240, 277, 380, 480, 600V<br />

DC DC 12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250V<br />

These capacitive contactors are suitable for switching singlestep<br />

or multiple-step condenser bank.<br />

It is standardized by IEC-60947-4941, UL and CSA.<br />

Features of capacitor unit(Pre-loading resistor)<br />

- Damping resister that can limit the inrush current upto 60×In<br />

is connected to the mechanism that closed earlier than the<br />

main contact of the contactor<br />

- No heat loss by the serial resistor<br />

- Eliminate the switching surge<br />

- Improving the performance of the capacitor system<br />

T1<br />

Power<br />

transformer<br />

MCCB<br />

Capacitor unit<br />

Condenser bank<br />

Heating coil<br />

or motor<br />

Capacitive<br />

contactors<br />

78<br />

Example


2-pole AC <strong>Contactor</strong>s, Definite purpose<br />

Description<br />

- Two normally open main contacts<br />

- Screw clamp or fast-on connections<br />

- Small and light design suitable for use in air conditioners, heaters, refrigerators, etc.<br />

- Screw mountable<br />

- No auxiliary contact<br />

- AC control voltage<br />

Ratings<br />

Main terminal<br />

Type<br />

AC3 ratings<br />

Ith<br />

Contact<br />

220~240V 380~440V 500~550V NO NC<br />

GMC-10P2 10A 8A 6A 20A 2 -<br />

GMC-20P2 20A 17A 14A 30A 2 -<br />

GMC-25P2 25A 21A 17A 35A 2 -<br />

GMC-30P2 30A 23A 21A 40A 2 -<br />

GMC-35P2 35A 26A 23A 45A 2 -<br />

GMC-40P2 40A 32A 26A 50A 2 -<br />

Insulation voltage: 690V at AC, 250V at DC<br />

Screw clamp<br />

Fast-on (Quick connect)<br />

Coil terminal<br />

Control coil characteristics<br />

Coil consumption (VA) Thermal Operational voltage(V) Coil Operational time (ms)<br />

Coil voltage<br />

Inrush Holding dissipation current<br />

Pick-up Drop-out<br />

(W)<br />

(mA)<br />

Closing Opening<br />

24V 50/60Hz 35 6.0 2 18~20 10~15 263 40 30<br />

48V 50/60Hz 35 6.0 2 36~40 19~27 131 40 30<br />

100V 50/60Hz 35 6.0 2 74~81 39~57 63 40 30<br />

110V 50/60Hz 35 6.0 2 78~90 50~64 57 40 30<br />

120V 50/60Hz 35 6.0 2 90~100 52~66 53 40 30<br />

200V 50/60Hz 35 6.0 2 155~165 80~115 32 40 30<br />

220V 50/60Hz 35 6.0 2 160~175 90~120 29 40 30<br />

230V 50/60Hz 35 6.0 2 165~180 110~130 27 40 30<br />

240V 50/60Hz 35 6.0 2 168~185 110~135 26 40 30<br />

Screw clamp<br />

Fast-on<br />

(Quick connect)<br />

Note) 1. The condition of the above data: 60Hz. 20 ℃ from cold state<br />

2. Coil consumption (VA) is average value.<br />

Type numbering system<br />

GMC10P2 / 20 / 00 / F7 / AC /<br />

S<br />

Product (6A~2100A)<br />

Main contactor<br />

Auxiliary contact<br />

Coil voltage<br />

Coil consumption<br />

Terminal<br />

GMC10P2<br />

GMC20P2<br />

GMC25P2<br />

GMC30P2<br />

GMC35P2<br />

GMC40P2<br />

GMC-10P2<br />

GMC-20P2<br />

GMC-25PS<br />

GMC-30P2<br />

GMC-35P2<br />

GMC-40P2<br />

20 2NO0NC 00 None<br />

Coil code Table AC AC<br />

ex) GMC10P2-20-00-F7-AC-S-E GMC-10P2 AC110V 50/60Hz EXP<br />

GMC40P2-20-00-B7-AC-Q-E GMC-40P2 TQBQ AC24V 50/60Hz EXP<br />

S<br />

Q<br />

Screw<br />

Quick Connect<br />

79


3-pole AC <strong>Contactor</strong>s, Definite purpose<br />

Description<br />

- Three main contacts<br />

- Screw clamp connections<br />

- Small and light design suitable for use in air conditioners, heaters, refrigerators, etc.<br />

- Screw mountable<br />

- No auxiliary contact<br />

- AC control voltage<br />

Ratings<br />

AC3 ratings AC4 ratings Contact<br />

Type 220~ 380~ 500~ 220~ 380~ 500~ Ith<br />

GMC-20D2<br />

GMC-20D3<br />

GMC-25D2<br />

GMC-25D3<br />

240V 440V 550V 240V 440V 550V<br />

NO<br />

NC<br />

2 -<br />

20A 17A 14A 18A 13A 10A 30A 3 -<br />

2 1<br />

2 -<br />

25A 21A 17A 20A 14A 12A 35A 3 -<br />

Note) Above contact ratings are for NO contact.<br />

Rating for NC contact: 6A@120V, 3A@240V, 1.5A@480V at AC15 duty<br />

Rating above 24V 1A<br />

Please use NC contact for Insulation voltage: 690V at AC, 250V at DC<br />

2 1<br />

Control coil characteristics<br />

Coil voltage<br />

Coil consumption (VA) Thermal Operational voltage(V) Coil Operational time (ms)<br />

Inrush Holding dissipation Pick-up Drop-out<br />

(W)<br />

current<br />

(mA)<br />

Closing<br />

24V 60Hz 72 9.0 3 17~19 12.5~15.5 215 30 20<br />

48V 60Hz 72 9.0 3 32~36 26~30 125 30 20<br />

110V 60Hz 72 9.0 3 75~85 65~75 60 30 20<br />

220V 60Hz 72 9.0 3 150~170 120~145 41 30 20<br />

Note) 1. The condition of the above data: 60Hz. 20 ℃ from cold state<br />

2. Coil consumption (VA) is average value.<br />

Opening<br />

Type numbering system<br />

GMC20D2 / 20 / 00 / F7 / AC /<br />

S<br />

Product (6A~2100A)<br />

Main contactor<br />

Auxiliary contact<br />

Coil voltage<br />

Coil consumption<br />

Terminal<br />

GMC20D2<br />

GMC20D3<br />

GMC25D2<br />

GMC25P3<br />

GMC-10D2<br />

GMC-20D3<br />

GMC-25D2<br />

GMC-25D3<br />

20 2NO0NC<br />

30 2NO1NC<br />

21 3NO0NC<br />

00 None<br />

Coil code Table<br />

AC<br />

AC<br />

S<br />

Screw<br />

80


Single-pole AC <strong>Contactor</strong>s, Definite purpose<br />

Description<br />

- Single-pole NO main contact<br />

- Small and light design suitable for use in electric shock protector for AC arc welder<br />

- DIN rail or screw mountable<br />

- No auxiliary contact (Optional unit can be added up to 2NO2NC)<br />

- AC control voltage<br />

Ratings<br />

Type<br />

Rated current, In<br />

Performance<br />

Ith<br />

110/220V Making current Breaking current<br />

MC-65aSP 220A 500A 1.5×In<br />

Control coil characteristics<br />

Coil consumption (VA) Operational voltage Operational time<br />

Inrush Holding Pick-up Drop-out Closing<br />

150VA 17VA 85% under 20% over 30ms under<br />

Note) Coil voltage is available between AC24V and AC550V<br />

81


2-pole DC <strong>Contactor</strong>s<br />

Description<br />

- Two normally open main contacts for DC circuit<br />

- Positive and negative poles indicated on the front plate<br />

- Eternal magnet installed for the effective arc extinguishing<br />

- DIN rail or screw mountable<br />

- 2NO+2NC Auxiliary contacts built-in as standard<br />

- AC/DC control voltage<br />

Selection<br />

<strong>Contactor</strong> Type<br />

DC-2~5 ratings DC-1 rating Continuous<br />

125V 250V 500V 1000V current, Ith<br />

Auxiliary<br />

contacts<br />

MD-30a 40A 30A 20A 10A 60A 2a(NO)+2b(NC)<br />

MD-60a 80A 60A 40A 25A 100A 2a(NO)+2b(NC)<br />

MD-100a 120A 100A 60A 35A 135A 2a(NO)+2b(NC)<br />

Ratings of auxiliary contacts<br />

A1 A2 1<br />

2<br />

Current<br />

M<br />

5<br />

6<br />

UA-1<br />

AC15 duty<br />

DC13 duty<br />

120V 240V 380V 480V 500V 600V 125V 250V 400V 500V 600V<br />

Rated currents 6A 3A 1.9A 1.5A 1.4A 1.2A 1.1A 0.55A 0.31A 0.27A 0.2A<br />

Continuous current, Ith 16A<br />

Coil voltage<br />

AC 50/60Hz<br />

DC DC<br />

24, 48, 100, 110, 120, 200, 220, 230, 240, 380, 400, 415, 440, 500, 550V<br />

12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250V<br />

82


Accessory<br />

Auxiliary contact units<br />

- 2 and 4 pole<br />

- Side and front mountable<br />

- Common use for Metasol contactors from MC-6a to MC-150a<br />

- Auxiliary contact meet the requirements for mirror contacts in IEC 60947-4-1. Annex F (A mirror contact<br />

is an auxiliary NC contact that cannot be closed simultaneously with a NO main contact)<br />

MC-6a~MC-150a<br />

UA-1<br />

UA-1<br />

UA-2<br />

Selection<br />

Type Appearance Pole<br />

Composition<br />

NO<br />

NC<br />

UA-4<br />

Contact arrangement Mount Weight<br />

13(43)<br />

21(31)<br />

UA-1 2 1 1 Side 53g<br />

14(44) 22(32)<br />

2 -<br />

UA-2 2 1 1 Front 28g<br />

- 2<br />

53 63 51 63 51 61<br />

54 64 52 64 52 62<br />

2a 1a1b 2b<br />

53<br />

63<br />

73<br />

83<br />

53<br />

61<br />

73<br />

83<br />

53 61<br />

71<br />

83<br />

4 -<br />

3 1<br />

UA-4 4 2 2<br />

4a<br />

3a1b 2a2b<br />

Front 50g<br />

1 3<br />

- 4<br />

54 64 74 84 54 62 74 84 54 62 72 84<br />

51 63 71 81 51 61 71 81<br />

52<br />

64<br />

72<br />

82<br />

52<br />

62<br />

72<br />

82<br />

1a3b<br />

4b<br />

Maximum combination of contact units<br />

MC-6a~18a, 9b~22b (Max. 3a3b)<br />

UA-4(on front)+UA-1×1EA (1EA on one side)<br />

UA-2(on front)+UA-1×1EA (1EA on one side)<br />

UA-1×2EA (1EA on both sides)<br />

*To use UA-1, MC-9b~22b Type is avaliable on only left side<br />

MC-32a~150a (Max. 4a4b)<br />

UA-4(on front)+UA-1×2EA (1EA on both sides)<br />

UA-2(on front)+UA-1×2EA (1EA on both sides)<br />

UA-1×4EA (2EA on both sides) *For AC Coil<br />

83


Accessory<br />

Auxiliary contact units<br />

- 2 pole<br />

- Side mountable<br />

- Common use for Metasol contactors from MC-185a to MC-2100a<br />

- Auxiliary contact meet the requirements for mirror contacts in IEC 60947-4-1. Annex F<br />

(A mirror contact is an auxiliary NC contact that cannot be closed simultaneously with a NO main contact)<br />

MC-185a ~ MC-2100a<br />

AU-100<br />

AU-100E<br />

AU-100<br />

AU-100E<br />

Selection<br />

Type Appearance Pole<br />

Composition<br />

a(NO)<br />

b(NC)<br />

Contact arrangement Mount Weight<br />

13(43)<br />

21(31)<br />

AU-100 2 1 1<br />

AU-100E<br />

Side<br />

53g<br />

14(44) 22(32)<br />

Maximum combination of contact units<br />

MC-185a~2100a (Max. 4a4b)<br />

AU-100×4EA (2EA on both sides)<br />

AU-100E×4EA (2EA on both sides)<br />

84


Accessory<br />

Rating<br />

Type<br />

Rated operation voltage (Ue)<br />

Rated insulation voltage (Ui)<br />

Rated impulse withstand voltage (Uimp)<br />

Rated frequency<br />

Contact sensibility<br />

Voltage<br />

Current<br />

Rated thermal current (Ith, AC12 duty)<br />

Rated operation current<br />

AC15 duty 120V<br />

(A600) 240V<br />

380V<br />

480V<br />

500V<br />

600V<br />

DC13 duty 125V<br />

(Q600) 250V<br />

400V<br />

500V<br />

600V<br />

Rated<br />

1s<br />

Short-time 0.5s<br />

withstand current 0.1s<br />

Electrical lifetime (mil. operations)<br />

AC15 duty 220V<br />

440V<br />

DC13 duty 220V<br />

440V<br />

Maximum operating cycles per hour<br />

Conductor size (Solid, stranded) AWG<br />

(the max. number of conducts: 2) mm²<br />

UA-1 UA-2, 4 AU-100 AU-100E<br />

600V 600V 600V 60V<br />

600V 600V 600V 600V<br />

6kV 6kV 6kV 6kV<br />

50/60Hz 50/60Hz 50/60Hz 50/60Hz<br />

DC 17V DC 24V DC 24V DC 7V<br />

DC 5mA DC 10mA DC 10mA DC 5mA<br />

10A 16A 16A 1A<br />

6A 6A 6A<br />

3A 3A 3A<br />

1.9A 1.9A 1.9A<br />

1.5A 1.5A 1.5A<br />

1.4A 1.4A 1.4A<br />

AC/DC 24V 0.1A<br />

1.2A 1.2A 1.2A<br />

AC/DC 50V 0.01A<br />

1.1A 1.1A 1.1A<br />

0.55A 0.55A 0.55A<br />

0.31A 0.31A 0.31A<br />

0.27A 0.27A 0.27A<br />

0.2A 0.2A 0.2A<br />

100A - 100A -<br />

125A - 120A -<br />

145A - 140A -<br />

0.25 0.25 0.25<br />

0.25 0.25 0.25<br />

1<br />

0.25 0.25 0.25<br />

0.25 0.25 0.25<br />

1800 1800 1200<br />

18~10 18~10 18~10 18~10<br />

1~2.5 1~2.5 1~2.5 1~2.5<br />

Installation<br />

UA-1 1<br />

UA-2, 4<br />

2<br />

1<br />

3<br />

2<br />

To install side mounting unit remove the indicated<br />

part in the circle in the fig. first. And then fit each<br />

part as shown. To separate push forward and pull.<br />

To install front mounting unit fit it on the upper<br />

part of the front of the contactor and push it<br />

down. To separate pull the lever of the unit and<br />

push the unit upward.<br />

85


Accessory<br />

Mechanical latch unit ML, AL<br />

Mechanical latch unit<br />

<strong>Contactor</strong><br />

Combined<br />

Ratings<br />

Applying contactors Type Coil voltage of latch unit<br />

MC-6a/L<br />

MC-9a/L<br />

MC-12a/L<br />

ML-65<br />

MC-18a/L<br />

MC-9b/L<br />

MC-12b/L<br />

MC-18b/L<br />

MC-22b/L<br />

MC-32a/L<br />

MC-40a/L<br />

MC-50a/L<br />

MC-65a/L<br />

MC-75a/L<br />

MC-85a/L<br />

MC-100a/L<br />

MC-130a/L<br />

MC-150a/L<br />

ML-65<br />

ML-150<br />

Ordering voltage<br />

AC 24V/ DC 24V<br />

AC 48V/ DC 48V<br />

AC 100V/DC 100V<br />

AC 200V/DC 200V<br />

AC 400V<br />

Operation voltage<br />

AC 24V 50/60Hz, DC 24V<br />

AC 48V 50/60Hz, DC 48V<br />

AC 100~127V 50/60Hz,<br />

DC 100V~125V<br />

AC 200~240V 50/60Hz,<br />

DC 200V~220V<br />

AC 380V~440V 50/60Hz<br />

* Coils for 24, 48, 100, 200V are AC / DC common.<br />

MC-185a/L, 225a/L<br />

AL-225<br />

Ordering voltage Operation voltage<br />

AC 100V AC 100~127V 50/60Hz, DC 100~110V<br />

AC 200V AC 200~240V 50/60Hz, DC 200~220V<br />

MC-265a/L, 330a/L, 400a/L<br />

AL-400<br />

* For using safely the product providing DC control power, Please<br />

consider that the maximum switching frequency should be less than<br />

150 times/hour.<br />

Note) Latch units for upto MC-150 are supplied seperately. From MC-185 the units are assembled at factory.<br />

To install<br />

1<br />

2<br />

1. Push the black bar<br />

1<br />

2. Position the Latch on the top of the contactor<br />

3. 3 Pull in the direction of the arrow until snapping<br />

3<br />

2<br />

1<br />

3<br />

2<br />

To separate<br />

1<br />

3<br />

2<br />

1. Pull the black lever in the direction of the arrow.<br />

2. Pull up the yellow lever.<br />

3. Push the latch in the direction of the arrow.<br />

86


Accessory<br />

Delayed opening devices, AD<br />

Delayed opening device prevents the inadvertent opening of a contactor in the event of a wide<br />

voltage drop or brief supply voltage interruptions of control power for 1 to 4 seconds.<br />

Applying<br />

MC<br />

Durability<br />

Type Rated voltage<br />

Performance<br />

contactors<br />

Rated voltage Mechanical Electrical<br />

MC-6a~40a<br />

AC 110V DC 110V<br />

AD-9<br />

•Making/Breaking capacity at AC3<br />

MC-9b~22b AC 220V DC 220V<br />

1 mil - Making current : min. 10xIn<br />

AC 110V DC 110V<br />

operations - Breaking current : min. 8xIn<br />

MC-50a~100a AD-50<br />

•Max. operating rate : 600 operations/hour<br />

AC 220V DC 220V 5 mil<br />

•Delaying time : 1~4sec.<br />

MC-130a~225a AD-100 AC 100~240V AC/DC 100~240V operations<br />

•Capacitor durability<br />

1) Operation :> 0.1 mil. operations<br />

MC-265a~400a AD-300 AC 100~240V AC/DC 100~240V<br />

0.5 mil 2) Cumulative charge life at AC 200/220V<br />

AC 100~127V AC/DC 100~127V<br />

operations - 45℃ or less: 80,000 hours<br />

MC-500a~800a AD-600 - 50℃ or less: 60,000 hours<br />

AC 200~240V AC/DC 200~240V<br />

* AD shall ve used for DC type contactor<br />

Electronic timer unit, UT<br />

Applying contactors Type Rated voltage Performance<br />

1Insult to<br />

1way 2Push<br />

to 2way and<br />

assemble<br />

MC-6a~150a<br />

MC-9b~22b<br />

MR-4~8<br />

On delay<br />

Off delay<br />

Terminal cover units for contactors, AP<br />

UT-1N<br />

UT-2N<br />

UT-1F<br />

UT-2F<br />

AC/DC 24~48V<br />

AC 110~220V<br />

AC/DC 24~48V<br />

AC 110~220V<br />

•Mounting: Head on<br />

•Contact: 1c<br />

•Time delay: 1 Sec~30 Sec On delay,<br />

Off delay<br />

•Frequency: AC 50/60Hz<br />

•Operation: Min. voltage 85%,<br />

Max. voltage 110%<br />

•Accuracy of setting time: ±20%<br />

Type<br />

Applying contactors<br />

Standard Transparent<br />

MC-9b,12b,18b,22b (22AF) - AP-9<br />

MC-32a,40a (40AF) - AP-32<br />

MC-50,65a (65AF) - AP-50<br />

MC-130a,150a (150AF) - AP-75<br />

MC-185a,225a (225AF) AP-220 AP/T-185<br />

MC-265a,330a,400a (400AF) AP-400 AP/T-265<br />

MC-500a,630a,800 (800AF) AP-800 AP/T-500<br />

Remarks<br />

2 pcs included<br />

Insulation barrier units, AI<br />

Applying contactors Type Remarks<br />

MC-130a, 150a (150AF)<br />

MC-185a, 225a (225AF)<br />

MC-265a, 330a, 400a (400AF)<br />

MC-500a, 630a, 800a, 1260a (800AF)<br />

MC-1400a, 1700a, 2100a (2100AF)<br />

AI-180<br />

AI-800<br />

AI-2100<br />

4 pcs required per contactor<br />

* The insulation barrier for MC-150a is available on the screw type only.<br />

87


Accessory<br />

Interlocks<br />

Component parts for assembling by customer<br />

Interlock unit, UR-02 and AR-9 & Wire kit UW<br />

UR-02 is a mechanical interlock unit and provides 2NC contacts for use in<br />

electrical interlocking<br />

Interlock unit<br />

Wire kit<br />

UW is used for making reversing circuit between two contactors.<br />

<strong>Contactor</strong><br />

Pole<br />

Wire kit Interlock unit Aux<br />

Type Weight Type Weight Contact<br />

MC-6a~18a<br />

3P UW-18 0.05kg<br />

4P - -<br />

2NC<br />

MC-9b~22b<br />

UW-22 0.04kg -<br />

MC-32a~40a UW-32 0.05kg UR-02 0.06kg -<br />

MC-50a, 65a 3P UW-63 0.12kg -<br />

MC-75a~100a UW-95 0.33kg -<br />

MC-130a~150a - - -<br />

MC-22a~85a 4P - - AR-9 0.05kg -<br />

Rating of the contacts in the interlocks<br />

Rated operation voltage<br />

600V<br />

Rated insulation voltage<br />

600V<br />

Rated frequency<br />

50/60Hz<br />

Rated thermal current<br />

10A<br />

Rated operation current<br />

AC15 duty 120V 6A<br />

(A600) 240V 3A<br />

380V 1.9A<br />

480V 1.5A<br />

500V 1.4A<br />

600V 1.2A<br />

DC13 duty 125V 0.55A<br />

(Q300) 250V 0.27A<br />

A1<br />

A2<br />

R/1/L1 S/3/L2 T/5/L3<br />

111NC<br />

121NC<br />

R/1/L1 S/3/L2<br />

T/5/L3<br />

A1<br />

A2<br />

A1<br />

A2<br />

112NC<br />

122NC<br />

A1<br />

A2<br />

U/2/T1<br />

V/4/T2<br />

W/6/T3<br />

U/2/T1<br />

V/4/T2<br />

W/6/T3<br />

88<br />


Accessory<br />

Interlock unit, AR-180 and AR-600<br />

AR-180 and AR-600 are mechanical interlock units in which electrical contacts for<br />

use in electrical interlocking are not included. Please use the auxiliary contacts on<br />

the sides of the contactors for that purpose.<br />

AR-180<br />

AR-600<br />

<strong>Contactor</strong><br />

MC-100a<br />

MC-130a<br />

MC-150a<br />

MC-185a<br />

MC-225a<br />

MC-265a<br />

MC-330a<br />

MC-400a<br />

MC-500a<br />

MC-630a<br />

MC-800a<br />

Interlock unit<br />

Pole<br />

Type<br />

Weight<br />

4P<br />

AR-180<br />

0.09kg<br />

3,4P<br />

3,4P AR-600 15.2kg<br />

*AR-600 3pole product is different fro, AR-600 4pole product in size.<br />

Installation of Interlock and Wire kits<br />

<br />

2<br />

1<br />

Click<br />

1<br />

2<br />

Click<br />

Install the interlock unit on<br />

the side of a contactor first.<br />

Fit each part as indicated in<br />

the fig.<br />

And then install the other<br />

contactor on the other side<br />

of the interlock unit as<br />

shown.<br />

After installing interlock unit wiring kit can be<br />

assembled.<br />

Wiring kit contains two molded wires - one for line<br />

side and the other for load side.<br />

- In case of assembling Reversing contactor, please check<br />

the R, S, T/U, V, Wmark on the contactor and Wire kit.<br />

89


Accessory<br />

Surge unit<br />

US Type<br />

It absorbs the surge arisen out of the coil of the contactor.<br />

It can be installed simply to the contactor.<br />

- Rated operation voltage (Ue): AC 24 ~ 440V / DC 24 ~ 125V<br />

- Rated insulation voltage (Ui): 1000V<br />

- Rated impulse withstand voltage (Uimp): 8kV<br />

- Degree of protection: IP20<br />

- Combination with 3Pole 6a/3~150a/3, 4Pole 32a/4~85a/4<br />

AS Type<br />

US Type<br />

Surge unit<br />

Internal elements spec.<br />

Rated voltage<br />

Type Composition V R C<br />

US-1 Varistor+RC 24~48V 120V 100Ω 0.1μF<br />

US-2 Varistor+RC AC 100~125V 270V 100Ω 0.1μF<br />

US-3 Varistor+RC 200~240V 470V 100Ω 0.1μF<br />

US-4 Varistor+RC 24~48V 120V 100Ω 0.47μF<br />

US-5 Varistor+RC DC 100~125V 270V 100Ω 0.47μF<br />

US-6 Varistor+RC 200~220V 470V 100Ω 0.47μF<br />

US-11 Varistor 24~48V 120V - -<br />

US-12 Varistor AC/DC 100~125V 270V - -<br />

US-13 Varistor common 200~240V 470V - -<br />

US-14 Varistor 380~440V 1000V - -<br />

US-22 RC AC 100~125V - 56Ω 1μF<br />

<strong>Contactor</strong><br />

3Pole MC<br />

6a~150a<br />

9b~22b<br />

Installation<br />

(US Type)<br />

Click<br />

AS Type<br />

Surge unit<br />

Internal elements spec.<br />

Rated voltage<br />

Type Composition V R C<br />

AS-1 Varistor+RC 24~48V 120V 100Ω 0.1μF<br />

AS-2 Varistor+RC AC 100~125V 270V 100Ω 0.1μF<br />

AS-3 Varistor+RC 200~240V 470V 100Ω 0.1μF<br />

AS-4 Varistor+RC 24~48V 120V 100Ω 0.47μF<br />

AS-5 Varistor+RC DC 100~125V 270V 100Ω 0.47μF<br />

AS-6 Varistor+RC 200~220V 470V 100Ω 0.47μF<br />

AS-11 Varistor 24~48V 120V - -<br />

AC/DC<br />

AS-12 Varistor<br />

100~125V 270V - -<br />

common<br />

AS-13 Varistor<br />

200~240V 470V - -<br />

AS-14 Varistor AC 380~440V 1000V - -<br />

<strong>Contactor</strong><br />

3Pole MC<br />

185a~800a<br />

4Pole MC<br />

22a/4~800a/4<br />

Specitication of surge unit<br />

Without surge unit<br />

1 With Varistor unit<br />

2 With CR+Varistor unit<br />

Connect the lead wires to the<br />

coil terminals of the contactor<br />

first. And then insert the body<br />

into the space of the contactor<br />

as shown above.<br />

Surge voltage, arise when the coil is off,<br />

may provoke mis-operation and<br />

damage in the circuit.<br />

Varistor has an effect to cut down the<br />

peak voltage<br />

Varistor has an effect to cut down the<br />

peak voltage and high frequency wave<br />

90


Capacitor unit<br />

Capacitor unit is connected to the terminals of the contactor to reduce the high inrush current.<br />

IEC 60947-4-1 AC 6b<br />

Current<br />

Type AC-9 (1b) AC-50 (1b) AC-75 (1b)<br />

Rating thermal current (Ith) 16A 16A 16A<br />

120V 6 6 6<br />

Rated<br />

240V 3 3 3<br />

AC-15<br />

Operational 380V 1.9 1.9 1.9<br />

Current<br />

480V 1.5 1.5 1.5<br />

(A)<br />

500V 1.4 1.4 1.4<br />

600V 1.2 1.2 1.2<br />

Rated<br />

125V 0.55 0.55 0.55<br />

DC-13<br />

Operational<br />

250V 0.27 0.27 0.27<br />

Current<br />

400V 0.15 0.15 0.15<br />

(A)<br />

500V 0.13 0.13 0.13<br />

600V 0.1 0.1 0.1<br />

Note) - When the switch is closed condenser must be discharged before recharged. (Maximum residual voltage at terminals ≤ 50V)<br />

- To prevent short current, gG type fuse must be 1.5~2 times than rated current.<br />

Features of capacitor unit (Pre-loading resistor)<br />

- Damping resister that can limit the inrush current upto 60×In is connected to the mechanism<br />

that closed earlier than the main contact of the contactor<br />

- No heat loss by the serial resistor<br />

- Eliminate the switching surge<br />

- Improving the performance of the capacitor system<br />

Operation sequence<br />

Capacitor unit: OFF<br />

<strong>Contactor</strong>: OFF<br />

Capacitor unit: ON<br />

<strong>Contactor</strong>: OFF<br />

Capacitor unit: OFF<br />

<strong>Contactor</strong>: ON<br />

Capacitor unit<br />

Capacitor unit<br />

Capacitor unit<br />

<strong>Contactor</strong><br />

<strong>Contactor</strong><br />

<strong>Contactor</strong><br />

Fig.1 Fig.2 Fig.3<br />

Note) Closing sequence: Fig.1 => Fig.2 => Fig.3<br />

Opening sequence: Fig.3 => Fig.1<br />

91


Accessory<br />

Replacement coils<br />

To replace the existing coil to change voltage or repair.<br />

Replacement process<br />

Coil voltage<br />

<strong>Contactor</strong> AC coil DC coil<br />

AC 60Hz (V) AC 50Hz (V) AC 50/60Hz (V) DC (V)<br />

24 230 24 230 24 240<br />

48 240 36 240 48 380<br />

MC-6a 100 277 42 380 100 415<br />

MC-9a 110 380 48 400 110 440<br />

MC-12a 120 440 80 415 120 500<br />

-<br />

MC-18a 200 480 100 440 200 550<br />

MR-4, 6, 8 208 600 110 500 220<br />

220 220 550 230<br />

24 230 24 230 24 240<br />

48 240 36 240 48 380<br />

MC-9b 100 277 42 380 100 415<br />

MC-12b 110 380 48 400 110 440<br />

MC-18b 120 440 80 415 120 500<br />

-<br />

MC-22b 200 480 100 440 200 550<br />

208 600 110 500 220<br />

220 220 550 230<br />

24 230 24 230 24 240 12 110<br />

48 240 36 240 48 380 20 125<br />

100 277 42 380 100 415 24 200<br />

110 380 48 400 110 440 48 220<br />

MC-32a<br />

120 440 80 415 120 500 60 250<br />

MC-40a<br />

200 480 100 440 200 550 80<br />

208 600 110 500 220 100<br />

220 220 550 230<br />

24 230 24 230 24 240 12 110<br />

48 240 36 240 48 380 20 125<br />

100 277 42 380 100 415 24 200<br />

MC-50a 110 380 48 400 110 440 48 220<br />

MC-65a 120 440 80 415 120 500 60 250<br />

200 480 100 440 200 550 80<br />

208 600 110 500 220 100<br />

220 220 550 230<br />

24 230 24 230 24 240 12 110<br />

48 240 36 240 48 380 20 125<br />

100 277 42 380 100 415 24 200<br />

MC-75a<br />

110 380 48 400 110 440 48 220<br />

MC-85a<br />

120 440 80 415 120 500 60 250<br />

MC-100a<br />

200 480 100 440 200 550 80<br />

208 600 110 500 220 100<br />

220 220 550 230<br />

24 220~240 24 110<br />

MC-130a 48 300 48 220<br />

- -<br />

MC-150a 100~240 380~440 70~110<br />

110~120 500 100~220<br />

92


To replace the existing coil to change voltage or repair.<br />

<strong>Contactor</strong><br />

AC/DC common coil (V)<br />

Coil voltage<br />

AC coil (V)<br />

MC-185a<br />

MC-225a<br />

24 300<br />

48 400<br />

100~240/100~220 500<br />

MC-300a<br />

100~240/100~220<br />

400<br />

MC-400a 500<br />

MC-500a<br />

300<br />

100/100<br />

MC-630a<br />

400<br />

200/200<br />

MC-800a 500<br />

MC-1260a 100~240/100~220 -<br />

MC-1400a<br />

MC-1700a 100~240/100~220 -<br />

MC-2100a<br />

Safety cover (Option)<br />

To prevent arc from coming out from the contactor<br />

To protect from unintended manual operation<br />

To prevent dust from entering into the inside of the<br />

contactor<br />

Type<br />

AP-9<br />

AP-185<br />

<strong>Contactor</strong><br />

MC-6a~150a<br />

MC-185a~800a<br />

93


<strong>Overload</strong> relays<br />

General descriptions<br />

Type MT, bimetal-style, overload relays are designed to protect AC circuits and motors against<br />

overloads, phase failure, long starting times and prolonged stalling of the motor.<br />

Four versions are available according to the protection function and trip class as below.<br />

1. Non-differential: 3pole-2bimetal(heater) and trip class 10A<br />

2. Non-differential: 3pole-3bimetal(heater) and trip class 10A<br />

3. Differential: 3pole-3bimetal(heater) and trip class 10A<br />

4. Differential: 3pole-3bimetal(heater) and trip class 20<br />

Configuration of the front<br />

Upstream<br />

connections<br />

Relay type<br />

Trip indicator<br />

Protection cover<br />

Adjustment dial<br />

Sealing the protection cover<br />

Stop/Test button<br />

Reset button/Selector<br />

(manual or automatic reset)<br />

Auxiliary<br />

contacts(1NO+1NC)<br />

Downstream connections<br />

MT-12<br />

MT-32 MT-63 MT-95<br />

94


Environment and auxiliary circuit<br />

Environment<br />

Standards<br />

Certifications<br />

Rated operation voltage<br />

Rated insulation voltage<br />

Rated frequency<br />

Degree of protection (Conforming to IEC 60 529)<br />

Ambient air temperature<br />

Storage<br />

Operation<br />

Mounting position<br />

Shock resistance (Conforming to IEC 68-2-7)<br />

Vibration resistance (Conforming to IEC68-2-6)<br />

Insulation strength (Conforming to IEC 255-5)<br />

Rated impulse withstand voltage (Conforming to IEC 801-5)<br />

Auxiliary contacts characteristics<br />

Composition<br />

Rated thermal current<br />

Rated operation current<br />

AC15 duty<br />

120V<br />

(C600)<br />

240V<br />

380V<br />

480V<br />

500V<br />

600V<br />

DC13 duty<br />

120V<br />

(R300)<br />

240V<br />

Connecting conductor<br />

Size<br />

Connection to screw clamp terminals Type<br />

MT-12~800<br />

IEC/EN 60947-1, IEC/EN 60947-4-1<br />

CE, CSA, UL, CCC<br />

Max. 690V<br />

690V<br />

50/60Hz<br />

IP 20<br />

-30 ~ +65°C<br />

-25 ~ +60°C (MT refer to Graph)<br />

Vertical plane<br />

15gn - 11ms<br />

6G<br />

6kV<br />

6kV<br />

1NO +1NC<br />

5A<br />

C600, R300<br />

1.5A<br />

0.75A<br />

0.47A<br />

0.375A<br />

0.35A<br />

0.3A<br />

0.22A<br />

0.1A<br />

18AWG /1mm2<br />

65/75℃ Cu-wire<br />

MT-150 MT-225 MT-400 MT-800<br />

95


<strong>Overload</strong> relay specifications<br />

MT type<br />

Thermal <strong>Overload</strong> Relays<br />

2<br />

1<br />

3<br />

1 Main terminals/upstream<br />

2 Main terminals/downstream<br />

3 Auxiliary terminals<br />

Frame size<br />

Trip class<br />

Type<br />

Non-differential(3P-2 heater)<br />

Non-differential(3P-3 heater)<br />

Differential type<br />

Terminals<br />

Main-upstream<br />

Main-downstream<br />

Auxiliary<br />

Number of poles<br />

Rated operational voltage (Ue)<br />

Rated insulation voltage (Ui)<br />

Rated impulse voltage (Uimp)<br />

Degree of protection (IEC 60 529)<br />

Temperature compensation (°C)<br />

Functions<br />

Trip indicating<br />

Stop<br />

Test<br />

Manual/Automatic Reset<br />

Setting range(A)<br />

Nominal<br />

Wire size<br />

current rating mm² AWG<br />

0.14<br />

0.21<br />

0.33<br />

0.52<br />

0.82<br />

1.3<br />

1 18<br />

2.1<br />

3.3<br />

5<br />

6.5<br />

7.5<br />

8.5<br />

1~1.5 18~16<br />

11 1.5~2.5 16~14<br />

15 2.5 14~12<br />

19<br />

21.5<br />

2.5~4 12~10<br />

27 4~6 10<br />

30 4~10 10~8<br />

34 6~10 10~8<br />

42<br />

54<br />

10 8<br />

65<br />

74<br />

16~25 6~4<br />

83<br />

90<br />

25~35 4~3<br />

Applied contactors<br />

Separate mounting unit<br />

18AF<br />

10A 20<br />

MT-12/2HS -<br />

MT-12/3HS -<br />

MT-12/3KS<br />

MT-12/3DS<br />

Screw clamp<br />

Screw clamp<br />

Screw clamp<br />

3<br />

690V<br />

Up to 690V<br />

6kV<br />

IP 20<br />

-5~+40℃<br />

■<br />

-<br />

■<br />

■<br />

0.1~18A 1~18A<br />

0.1~0.16<br />

0.16~0.25<br />

0.25~0.4<br />

0.4~0.63<br />

0.63~1<br />

1~1.6 1~1.6<br />

1.6~2.5 1.6~2.5<br />

2.5~4 2.5~4<br />

4~6 4~6<br />

5~8 5~8<br />

6~9 6~9<br />

7~10 7~10<br />

9~13 9~13<br />

12~18 12~18<br />

MC-6a, 9a, 12a, 18a<br />

UZ-12<br />

Note : Screw clamp and Lug types are available for the main terminals of 65AF, 100AF and 150AF relays.<br />

The other AF relays provide Screw clamp types only.<br />

96


40AF<br />

65AF<br />

100AF<br />

10A 20 10A 20<br />

MT-32/2HS - MT-63/2HS/L -<br />

MT-32/3HS - MT-63/3HS/L -<br />

MT-32/3KS MT-32/3DS MT-63/3KS/L MT-63/3DS/L<br />

Screw clamp<br />

Screw/Lug clamp<br />

Screw clamp<br />

Screw/Lug clamp<br />

Screw clamp<br />

Screw clamp<br />

3 3<br />

690V<br />

690V<br />

Up to 690V<br />

Up to 690V<br />

6kV<br />

6kV<br />

IP 20 IP 20<br />

-5~+40℃ -5~+40℃<br />

■<br />

■<br />

■<br />

■<br />

■<br />

■<br />

■<br />

■<br />

0.1~40A 1~40A 4~65A<br />

10A 20<br />

MT-95/2HS/L -<br />

MT-95/3HS/L -<br />

MT-95/3KS/L MT-95/3DS/L<br />

Screw/Lug clamp<br />

Screw/Lug clamp<br />

Screw clamp<br />

3<br />

690V<br />

Up to 690V<br />

6kV<br />

IP 20<br />

-5~+40℃<br />

■<br />

■<br />

■<br />

■<br />

7~100A<br />

0.1~0.16<br />

0.16~0.25<br />

0.25~0.4<br />

0.4~0.63<br />

0.63~1<br />

1~1.6 1~1.6<br />

1.6~2.5 1.6~2.5<br />

2.5~4 2.5~4<br />

4~6 4~6 4~6 4~6<br />

5~8 5~8 5~8 5~8<br />

6~9 6~9 6~9 6~9<br />

7~10 7~10 7~10 7~10<br />

9~13 9~13 9~13 9~13<br />

12~18 12~18 12~18 12~18<br />

16~22 16~22 16~22 16~22<br />

18~25 18~25 18~25 18~25<br />

22~32 22~32 - -<br />

- - 24~36 24~36<br />

28~40 28~40 28~40 28~40<br />

34~50 34~50<br />

45~65 45~65<br />

MC-9b, 12b, 18b, 22b, 32a, 40a<br />

MC-50a, 65a<br />

UZ-32<br />

UZ-63S/L<br />

7~10 7~10<br />

9~13 9~13<br />

12~18 12~18<br />

16~22 16~22<br />

18~25 18~25<br />

- -<br />

24~36 24~36<br />

28~40 28~40<br />

34~50 34~50<br />

45~65 45~65<br />

54~75 54~75<br />

63~85 63~85<br />

70~95 70~95<br />

80~100 80~100<br />

MC-75a, 85a, 100a<br />

UZ-95S/L<br />

97


<strong>Overload</strong> relay specifications<br />

MT type<br />

Thermal <strong>Overload</strong> Relays<br />

2<br />

1<br />

3<br />

1 Main terminals/upstream<br />

2 Main terminals/downstream<br />

3 Auxiliary terminals<br />

Frame size<br />

Trip class<br />

Type<br />

Non-differential(3P-2 heater)<br />

Non-differential(3P-3 heater)<br />

Differential type<br />

Terminals<br />

Main-upstream<br />

Main-downstream<br />

Auxiliary<br />

Number of poles<br />

Rated operational voltage (Ue)<br />

Rated insulation voltage (Ui)<br />

Rated impulse voltage (Uimp)<br />

Degree of protection (IEC 60 529)<br />

Temperature compensation (°C)<br />

Functions<br />

Trip indicating<br />

Stop<br />

Test<br />

Manual/Automatic Reset<br />

Setting range(A)<br />

Nominal<br />

Wire size<br />

current rating mm² AWG<br />

42 10 8<br />

55 16 6<br />

65 25 4<br />

74 25 4<br />

80 35 3<br />

93 35 2<br />

107 50 1<br />

113 50 1<br />

130 50 0<br />

130 70 00<br />

153 95 000<br />

200 120 250<br />

265 185 350<br />

350 240 500<br />

515 185×2n 350×2n<br />

660 240×2n 300×3n<br />

Applied contactors<br />

Separate mounting unit<br />

150AF<br />

10A 20<br />

MT-150/2HS/L -<br />

MT-150/3HS/L -<br />

MT-150/3KS/L MT-150/3DS/L<br />

Screw/Lug clamp<br />

Screw/Lug clamp<br />

Screw clamp<br />

3<br />

690V<br />

690V<br />

6kV<br />

IP 20<br />

-5~+40℃<br />

■<br />

■<br />

■<br />

■<br />

34~150A 34~150A<br />

34~50<br />

45~65<br />

54~75<br />

63~85<br />

-<br />

80~105<br />

-<br />

95~130<br />

110~150<br />

MC-130a, 150a<br />

UZ-150S/L<br />

Note : Screw clamp and Lug types are available for the main terminals of 65AF, 100AF and 150AF relays.<br />

The other AF relays provide Screw clamp types only.<br />

98


225AF<br />

400AF<br />

800AF<br />

10A 20 10A 20<br />

MT-225/2HS - MT-400/2HS -<br />

MT-225/3HS - MT-400/3HS -<br />

MT-225/3KS MT-225/3DS MT-400/3KS MT-400/3DS<br />

Screw clamp<br />

Screw clamp<br />

Screw clamp<br />

Screw clamp<br />

Screw clamp<br />

Screw clamp<br />

3 3<br />

690V<br />

690V<br />

690V<br />

690V<br />

6kV<br />

6kV<br />

IP 20 IP 20<br />

-5~+40℃ -5~+40℃<br />

■<br />

■<br />

■<br />

■<br />

■<br />

■<br />

■<br />

■<br />

65~240A 65~240A 85~400A 85~400A<br />

10A 20<br />

MT-800/2HS -<br />

MT-800/3HS -<br />

MT-800/3KS MT-800/3DS<br />

Screw clamp<br />

Screw clamp<br />

Screw clamp<br />

3<br />

690V<br />

690V<br />

6kV<br />

IP 20<br />

-5~+40℃<br />

■<br />

■<br />

■<br />

■<br />

200~800A 200~800A<br />

65~100<br />

-<br />

85~125<br />

-<br />

-<br />

100~160<br />

120~185<br />

160~240<br />

MC-185a, 225a<br />

-<br />

85~125<br />

-<br />

-<br />

100~160<br />

120~185<br />

160~240<br />

200~330<br />

260~400<br />

MC-265a, 330a, 400a<br />

-<br />

200~300<br />

260~400<br />

400~600<br />

520~800<br />

MC-500a, 630a, 800a<br />

-<br />

99


<strong>Overload</strong> relay operation<br />

1<br />

2<br />

3<br />

4<br />

1. Adjustment dial<br />

A<br />

5<br />

4 6<br />

Before adjusting the dial open the protection cover.<br />

Current setting can be done easily by using (+) or (-) driver.<br />

Do not rotate the dial out of the setting range.<br />

2. Stop/Test button<br />

STOP<br />

TEST<br />

STOP function is executed by pushing the button,<br />

which causes the next sequence.<br />

In case of operation test pull this button.<br />

3.Trip indicator<br />

If relay is tripped it comes out.<br />

4. Reset button/Selector<br />

A<br />

2 9。 A<br />

1<br />

H H<br />

A<br />

Manual mode<br />

H<br />

H<br />

A<br />

Automatic mode<br />

Using a driver the reset mode can be set.<br />

In case of Manual mode(H) push the button to reset the relay.<br />

To change to Automatic mode(A) from Manual mode push the button and<br />

rotate as shown in the fig.<br />

5.Auxiliary contact operation<br />

Terminal no. Normal STOP TEST/TRIP RESET<br />

NC 95-96<br />

NO 97-98<br />

100


Accessories for overload relay<br />

Separate mounting units<br />

These accessories are used to mount the relays separately from contactors.<br />

If a relay is combined with a unit, it can be mounted on DIN rail or panel by<br />

fixing screws.<br />

Relay<br />

Type<br />

Unit<br />

Weight<br />

MT-12/2H<br />

MT-12/3H<br />

MT-12/3K<br />

UZ-12<br />

35g<br />

MT-12/3D<br />

MT-32/2H<br />

MT-32/3H<br />

MT-32/3K<br />

UZ-32<br />

68g<br />

MT-32/3D<br />

MT-63/2H<br />

MT-63/3H<br />

MT-63/3K<br />

UZ-63S/L<br />

134g<br />

MT-63/3D<br />

MT-95/2H<br />

MT-95/3H<br />

MT-95/3K<br />

UZ-95S/L<br />

230g<br />

MT-95/3D<br />

MT-150/2H<br />

MT-150/3H<br />

MT-150/3K<br />

UZ-150S/L<br />

284g<br />

MT-150/3D<br />

Terminal cover units for overload relays<br />

Relay<br />

MT-225<br />

MT-400<br />

Remarks<br />

2 pcs<br />

101


Accessories for overload relay<br />

Remote reset units<br />

These accessories are used to reset the relays on the panel door.<br />

Type<br />

UM-4R<br />

UM-5R<br />

UM-6R<br />

Cable length<br />

(L)<br />

400 mm<br />

500 mm<br />

600 mm<br />

1. Make the reset bar straight at least 55mm from the panel door and 35mm from the bracket.<br />

2. The bending radius of the flexible reset bar should not be less than 15mm.<br />

35<br />

55<br />

R15<br />

Ø10<br />

Bracket<br />

Reset Bar<br />

Panel door<br />

Ø8<br />

Door hole cutting<br />

102


Installation<br />

1. Fit the bracket with the relay as indicated(*1) below.<br />

2. Separate Nut(*3) and Head cap(*4) from the reset bar first.<br />

Insert the reset bar into the panel hole and then fix it with the Nut and Head.<br />

3. To separate the bracket from the relay lift the *2 part as shown in the fig.<br />

32AF 63AF 95AF<br />

Reset Bar<br />

Ø8<br />

* 3 * 4<br />

Bracket<br />

Panel door<br />

*1<br />

*2<br />

103


Accessories for overload relay<br />

Remote reset units<br />

MT-32<br />

<br />

<br />

<br />

<br />

<br />

<br />

MT-63<br />

<br />

<br />

<br />

MT-95<br />

104


Remote reset units<br />

MT-150<br />

<br />

<br />

<br />

MT-225<br />

<br />

<br />

<br />

MT-400<br />

<br />

<br />

<br />

MT-800<br />

<br />

<br />

<br />

105


<strong>Overload</strong> relay ordering types<br />

Trip class 10A<br />

Terminal type: Screw<br />

Degree of protection: IP20<br />

MT-12<br />

Setting range<br />

(A)<br />

Non-differential<br />

(3P-2 heater)<br />

Ordering type<br />

Non-differential<br />

(3P-3 heater)<br />

Differential<br />

<strong>Contactor</strong><br />

Separate<br />

mounting unit<br />

0.1~0.16 MT-12/2H0.14 MT-12/3H0.14 MT-12/3K0.14<br />

0.16~0.25 MT-12/2H0.21 MT-12/3H0.21 MT-12/3K0.21<br />

0.25~0.4 MT-12/2H0.33 MT-12/3H0.33 MT-12/3K0.33<br />

MT-12/<br />

0.4~0.63 MT-12/2H0.52 MT-12/3H0.52 MT-12/3K0.52<br />

0.63~1 MT-12/2H0.82 MT-12/3H0.82 MT-12/3K0.82<br />

1~1.6 MT-12/2H1.3 MT-12/3H1.3 MT-12/3K1.3<br />

1.6~2.5 MT-12/2H2.1 MT-12/3H2.1 MT-12/3K2.1<br />

2.5~4 MT-12/2H3.3 MT-12/3H3.3 MT-12/3K3.3<br />

4~6 MT-12/2H5 MT-12/3H5 MT-12/3K5<br />

5~8 MT-12/2H6.5 MT-12/3H6.5 MT-12/3K6.5<br />

6~9 MT-12/2H7.5 MT-12/3H7.5 MT-12/3K7.5<br />

7~10 MT-12/2H8.5 MT-12/3H8.5 MT-12/3K8.5<br />

9~13 MT-12/2H11 MT-12/3H11 MT-12/3K11<br />

12~18 MT-12/2H15 MT-12/3H15 MT-12/3K15<br />

MC-6a<br />

MC-9a<br />

MC-12a<br />

MC-18a<br />

UZ-12<br />

MT-32<br />

Setting range<br />

(A)<br />

Non-differential<br />

(3P-2 heater)<br />

Ordering type<br />

Non-differential<br />

(3P-3 heater)<br />

Differential<br />

<strong>Contactor</strong><br />

Separate<br />

mounting unit<br />

0.1~0.16 MT-32/2H0.14 MT-32/3H0.14 MT-32/3K0.14<br />

0.16~0.25 MT-32/2H0.21 MT-32/3H0.21 MT-32/3K0.21<br />

0.25~0.4 MT-32/2H0.33 MT-32/3H0.33 MT-32/3K0.33<br />

MT-32/<br />

0.4~0.63 MT-32/2H0.52 MT-32/3H0.52 MT-32/3K0.52<br />

0.63~1 MT-32/2H0.82 MT-32/3H0.82 MT-32/3K0.82<br />

1~1.6 MT-32/2H1.3 MT-32/3H1.3 MT-32/3K1.3<br />

1.6~2.5 MT-32/2H2.1 MT-32/3H2.1 MT-32/3K2.1<br />

2.5~4 MT-32/2H3.3 MT-32/3H3.3 MT-32/3K3.3<br />

4~6 MT-32/2H5 MT-32/3H5 MT-32/3K5<br />

5~8 MT-32/2H6.5 MT-32/3H6.5 MT-32/3K6.5<br />

6~9 MT-32/2H7.5 MT-32/3H7.5 MT-32/3K7.5<br />

7~10 MT-32/2H8.5 MT-32/3H8.5 MT-32/3K8.5<br />

9~13 MT-32/2H11 MT-32/3H11 MT-32/3K11<br />

12~18 MT-32/2H15 MT-32/3H15 MT-32/3K15<br />

16~22 MT-32/2H19 MT-32/3H19 MT-32/3K19<br />

18~25 MT-32/2H21.5 MT-32/3H21.5 MT-32/3K21.5<br />

22~32 MT-32/2H27 MT-32/3H27 MT-32/3K27<br />

28~40 MT-32/2H34 MT-32/3H34 MT-32/3K34<br />

MC-9b<br />

MC-12b<br />

MC-18b<br />

MC-22b<br />

MC-32a<br />

MC-40a<br />

UZ-32<br />

UZ-32(34A)<br />

106


Trip class 10A<br />

Terminal type: Screw(S), Lug(L)<br />

Degree of protection: IP20<br />

MT-63<br />

Setting range<br />

(A)<br />

Non-differential<br />

(3P-2 heater)<br />

Ordering type<br />

Non-differential<br />

(3P-3 heater)<br />

Differential<br />

<strong>Contactor</strong><br />

Separate<br />

mounting unit<br />

4~6 MT-63/2H5S/L MT-63/3H5S/L MT-63/3K5S/L<br />

5~8 MT-63/2H6.5S/L MT-63/3H6.5S/L MT-63/3K6.5S/L<br />

6~9 MT-63/2H7.5S/L MT-63/3H7.5S/L MT-63/3K7.5S/L<br />

MT-63/S<br />

MT-63/L<br />

7~10 MT-63/2H8.5S/L MT-63/3H8.5S/L MT-63/3K8.5S/L<br />

9~13 MT-63/2H11S/L MT-63/3H11S/L MT-63/3K11S/L<br />

12~18 MT-63/2H15S/L MT-63/3H15S/L MT-63/3K15S/L<br />

16~22 MT-63/2H19S/L MT-63/3H19S/L MT-63/3K19S/L<br />

18~25 MT-63/2H21.5S/L MT-63/3H21.5S/L MT-63/3K21.5S/L<br />

24~36 MT-63/2H30S/L MT-63/3H30S/L MT-63/3K30S/L<br />

28~40 MT-63/2H34S/L MT-63/3H34S/L MT-63/3K34S/L<br />

34~50 MT-63/2H42S/L MT-63/3H42S/L MT-63/3K42S/L<br />

45~65 MT-63/2H55S/L MT-63/3H55S/L MT-63/3K55S/L<br />

MC-50a<br />

MC-65a<br />

UZ-63S/L<br />

MT-95<br />

Setting range<br />

(A)<br />

Non-differential<br />

(3P-2 heater)<br />

Ordering type<br />

Non-differential<br />

(3P-3 heater)<br />

Differential<br />

<strong>Contactor</strong><br />

Separate<br />

mounting unit<br />

7~10 MT-95/2H8.5S/L MT-95/3H8.5S/L MT-95/3K8.5S/L<br />

9~13 MT-95/2H11S/L MT-95/3H11S/L MT-95/3K11S/L<br />

12~18 MT-95/2H15S/L MT-95/3H15S/L MT-95/3K15S/L<br />

MT-95/S<br />

MT-95/L<br />

16~22 MT-95/2H19S/L MT-95/3H19S/L MT-95/3K19S/L<br />

18~25 MT-95/2H21.5S/L MT-95/3H21.5S/L MT-95/3K21.5S/L<br />

24~36 MT-95/2H30S/L MT-95/3H30S/L MT-95/3K30S/L<br />

28~40 MT-95/2H34S/L MT-95/3H34S/L MT-95/3K34S/L<br />

34~50 MT-95/2H42S/L MT-95/3H42S/L MT-95/3K42S/L<br />

45~65 MT-95/2H55S/L MT-95/3H55S/L MT-95/3K55S/L<br />

54~75 MT-95/2H65S/L MT-95/3H65S/L MT-95/3K65S/L<br />

63~85 MT-95/2H74S/L MT-95/3H74S/L MT-95/3K74S/L<br />

70~95 MT-95/2H83S/L MT-95/3H83S/L MT-95/3K83S/L<br />

80~100 MT-95/2H90S/L MT-95/3H90S/L MT-95/3K90S/L<br />

MC-75a<br />

MC-85a<br />

MC-100a<br />

UZ-95S/L<br />

MT-150<br />

MT-150/S<br />

Ordering type<br />

Separate<br />

Setting range<br />

Non-differential<br />

<strong>Contactor</strong> mounting<br />

(A)<br />

Differential<br />

(3P-2 heater) (3P-3 heater) unit<br />

34~50 MT-150/2H42S/L MT-150/3H42S/L MT-150/3K42S/L<br />

45~65 MT-150/2H55S/L MT-150/3H55S/L MT-150/3K55S/L<br />

54~75 MT-150/2H65S/L MT-150/3H65S/L MT-150/3K65S/L<br />

MC-130a<br />

63~85 MT-150/2H74S/L MT-150/3H74S/L MT-150/3K74S/L<br />

MC-150a<br />

UZ-150S/L<br />

80~105 MT-150/2H93S/L MT-150/3H93S/L MT-150/3K93S/L<br />

95~130 MT-150/2H113S/L MT-150/3H113S/L MT-150/3K113S/L<br />

110~150 MT-150/2H130S/L MT-150/3H130S/L MT-150/3K130S/L<br />

107


<strong>Overload</strong> relay ordering types<br />

Trip class 10A<br />

Terminal type: Screw<br />

Degree of protection: IP20<br />

MT-225<br />

Setting range<br />

(A)<br />

Ordering type<br />

Non-differential<br />

(3P-2 heater)<br />

(3P-3 heater)<br />

Differential<br />

<strong>Contactor</strong><br />

Remarks<br />

65~100 MT-225/2H80 MT-225/3H80 MT-225/3K80<br />

MT-225/<br />

85~125 MT-225/2H107 MT-225/3H107 MT-225/3K107<br />

100~160 MT-225/2H130 MT-225/3H130 MT-225/3K130<br />

120~185 MT-225/2H153 MT-225/3H153 MT-225/3K153<br />

160~240 MT-225/2H200 MT-225/3H200 MT-225/3K200<br />

MC-185a<br />

MC-225a<br />

-<br />

MT-400<br />

Setting range<br />

(A)<br />

Ordering type<br />

Non-differential<br />

(3P-2 heater)<br />

(3P-3 heater)<br />

Differential<br />

<strong>Contactor</strong><br />

Remarks<br />

85~125 MT-400/2H107 MT-400/3H107 MT-400/3K107<br />

MT-400/<br />

100~160 MT-400/2H130 MT-400/3H130 MT-400/3K130<br />

120~185 MT-400/2H153 MT-400/3H153 MT-400/3K153<br />

160~240 MT-400/2H200 MT-400/3H200 MT-400/3K200<br />

200~330 MT-400/2H265 MT-400/3H265 MT-400/3K265<br />

260~400 MT-400/2H350 MT-400/3H350 MT-400/3K350<br />

MC-265a<br />

MC-330a<br />

MC-400a<br />

-<br />

MT-800<br />

Setting range<br />

(A)<br />

Ordering type<br />

Non-differential<br />

(3P-2 heater)<br />

(3P-3 heater)<br />

Differential<br />

<strong>Contactor</strong><br />

Remarks<br />

200~330 MT-800/2H265 MT-800/3H265 MT-800/3K265<br />

260~400 MT-800/2H350 MT-800/3H350 MT-800/3K350<br />

400~630 MT-800/2H515 MT-800/3H515 MT-800/3K515<br />

520~800 MT-800/2H660 MT-800/3H660 MT-800/3K660<br />

MC-500a<br />

MC-630a<br />

MC-800a<br />

-<br />

MT-800/<br />

108


Trip class 20<br />

Terminal type: Screw<br />

Degree of protection: IP20<br />

MT-12<br />

Setting range (A)<br />

Ordering type<br />

Differential<br />

<strong>Contactor</strong><br />

Separate mounting unit<br />

1~1.6 MT-12/3D1.3<br />

1.6~2.5 MT-12/3D2.1<br />

MT-12/3D<br />

2.5~4 MT-12/3D3.3<br />

4~6 MT-12/3D5<br />

5~8 MT-12/3D6.5<br />

6~9 MT-12/3D7.5<br />

7~10 MT-12/3D8.5<br />

9~13 MT-12/3D11<br />

12~18 MT-12/3D15<br />

MC-6a<br />

MC-9a<br />

MC-12a<br />

MC-18a<br />

UZ-12<br />

MT-32<br />

Setting range (A)<br />

Ordering type<br />

Differential<br />

<strong>Contactor</strong><br />

Separate mounting unit<br />

1~1.6 MT-32/3D1.3<br />

1.6~2.5 MT-32/3D2.1<br />

2.5~4 MT-32/3D3.3<br />

MT-32/3D<br />

4~6 MT-32/3D5<br />

5~8 MT-32/3D6.5<br />

6~9 MT-32/3D7.5<br />

7~10 MT-32/3D8.5<br />

9~13 MT-32/3D11<br />

12~18 MT-32/3D15<br />

16~22 MT-32/3D19<br />

18~25 MT-32/3D21.5<br />

22~32 MT-32/3D27<br />

28~40 MT-32/3D34<br />

MC-9b<br />

MC-12b<br />

MC-18b<br />

MC-22b<br />

MC-32a<br />

MC-40a<br />

UZ-32<br />

UZ-32(34A)<br />

109


<strong>Overload</strong> relay ordering types<br />

Trip class 20<br />

Terminal type: Screw(S), Lug(L)<br />

Degree of protection: IP20<br />

MT-63<br />

Setting range (A)<br />

Ordering type<br />

Differential<br />

<strong>Contactor</strong><br />

Separate mounting unit<br />

4~6 MT-63/3D5S/L<br />

5~8 MT-63/3D6.5S/L<br />

6~9 MT-63/3D7.5S/L<br />

7~10 MT-63/3D8.5S/L<br />

MT-63/ S<br />

9~13 MT-63/3D11S/L<br />

12~18 MT-63/3D15S/L<br />

16~22 MT-63/3D19S/L<br />

18~25 MT-63/3D21.5S/L<br />

24~36 MT-63/3D30S/L<br />

28~40 MT-63/3D34S/L<br />

34~50 MT-63/3D42S/L<br />

45~65 MT-63/3D55S/L<br />

MC-50a<br />

MC-65a<br />

UZ-63S/L<br />

MT-63/ L<br />

MT-95<br />

Setting range (A)<br />

Ordering type<br />

Differential<br />

<strong>Contactor</strong><br />

Separate mounting unit<br />

7~10 MT-95/3D8.5S/L<br />

9~13 MT-95/3D11S/L<br />

12~18 MT-95/3DK15S/L<br />

16~22 MT-95/3D19S/L<br />

MT-95/ S<br />

MT-95/ L<br />

18~25 MT-95/3D21.5S/L<br />

24~36 MT-95/3D30S/L<br />

28~40 MT-95/3D34S/L<br />

34~50 MT-95/3D42S/L<br />

45~65 MT-95/3D55S/L<br />

54~75 MT-95/3D65S/L<br />

63~85 MT-95/3D74S/L<br />

70~95 MT-95/3D83S/L<br />

80~100 MT-95/3D90S/L<br />

MC-75a<br />

MC-85a<br />

MC-100a<br />

UZ-95S/L<br />

MT-150<br />

Setting range (A)<br />

Ordering type<br />

Differential<br />

<strong>Contactor</strong><br />

Separate mounting unit<br />

34~50 MT-150/3D42S/L<br />

45~65 MT-150/3D55S/L<br />

MT-150/ S<br />

54~75 MT-150/3D65S/L<br />

63~85 MT-150/3D74S/L<br />

80~105 MT-150/3D93S/L<br />

95~130 MT-150/3D113S/L<br />

110~150 MT-150/3D130S/L<br />

MC-130a<br />

MC-150a<br />

UZ-150S/L<br />

110


Trip class 20<br />

Terminal type: Screw<br />

Degree of protection: IP20<br />

MT-225<br />

Setting range (A)<br />

Ordering type<br />

Differential<br />

<strong>Contactor</strong><br />

Remarks<br />

65~100 MT-225/3D80<br />

MT-225/3D<br />

85~125 MT-225/3D107<br />

100~160 MT-225/3D130<br />

120~185 MT-225/3D153<br />

160~240 MT-225/3D200<br />

MC-185a<br />

MC-225a<br />

-<br />

MT-400<br />

Setting range (A)<br />

Ordering type<br />

Differential<br />

<strong>Contactor</strong><br />

Remarks<br />

85~125 MT-400/3D107<br />

MT-400/3D<br />

100~160 MT-400/3D130<br />

120~185 MT-400/3D153<br />

160~240 MT-400/3D200<br />

200~330 MT-400/3D265<br />

260~400 MT-400/3D350<br />

MC-265a<br />

MC-330a<br />

MC-400a<br />

-<br />

MT-800<br />

Setting range (A)<br />

Ordering type<br />

Differential<br />

<strong>Contactor</strong><br />

Remarks<br />

200~330 MT-800/3D265<br />

260~400 MT-800/3D350<br />

400~630 MT-800/3D515<br />

520~800 MT-800/3D660<br />

MC-500a<br />

MC-630a<br />

MC-800a<br />

-<br />

MT-800/3D<br />

111


<strong>Overload</strong> relay trip curves<br />

Class 10A, 18AF<br />

MT-12/2H<br />

MT-12/3H<br />

MT-12/3K<br />

60<br />

40<br />

30<br />

20<br />

Cold starting<br />

60<br />

40<br />

30<br />

20<br />

Hot starting<br />

Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

2<br />

Tripping Time<br />

60<br />

40<br />

30<br />

20<br />

Tripping Time<br />

60<br />

40<br />

30<br />

20<br />

Second<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

Second<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

2<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

0.3<br />

1 2 3 4<br />

5 6 7 8 9 10 15<br />

0.3<br />

1 2<br />

3 4 5 6 7 8 9 10<br />

15<br />

Multiple of current setting<br />

× ln[A]<br />

Multiple of current setting<br />

× ln[A]<br />

Class 20, 18AF<br />

MT-12/3D<br />

60<br />

Cold starting<br />

60<br />

Hot starting<br />

40<br />

40<br />

30<br />

30<br />

20<br />

20<br />

Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

2<br />

Tripping Time<br />

60<br />

40<br />

30<br />

20<br />

Tripping Time<br />

60<br />

40<br />

30<br />

20<br />

Second<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

Second<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

2<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

0.3<br />

1 2 3 4<br />

5 6 7 8 9 10 15<br />

0.3<br />

1 2<br />

3 4 5 6 7 8 9 10<br />

15<br />

112<br />

Multiple of current setting<br />

× ln[A]<br />

Multiple of current setting<br />

× ln[A]


Class 10A, 40AF<br />

MT-32/2H<br />

MT-32/3H<br />

MT-32/3K<br />

60<br />

40<br />

30<br />

20<br />

Cold starting<br />

60<br />

40<br />

30<br />

20<br />

Hot starting<br />

Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

2<br />

Tripping Time<br />

60<br />

40<br />

30<br />

20<br />

Tripping Time<br />

60<br />

40<br />

30<br />

20<br />

Second<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

Second<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

2<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

0.3<br />

1 2 3 4<br />

5 6 7 8 9 10 15<br />

0.3<br />

1 2<br />

3 4 5 6 7 8 9 10<br />

15<br />

Multiple of current setting<br />

× ln[A]<br />

Multiple of current setting<br />

× ln[A]<br />

Class 20, 40AF<br />

MT-32/3D<br />

60<br />

Cold starting<br />

60<br />

Hot starting<br />

40<br />

40<br />

30<br />

30<br />

20<br />

20<br />

Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

2<br />

Tripping Time<br />

60<br />

40<br />

30<br />

20<br />

Tripping Time<br />

60<br />

40<br />

30<br />

20<br />

Second<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

Second<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

2<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

0.3<br />

1 2 3 4<br />

5 6 7 8 9 10 15<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

0.3<br />

1 2<br />

3 4 5 6 7 8 910<br />

15<br />

Multiple of current setting<br />

× ln[A]<br />

Multiple of current setting<br />

× ln[A]<br />

113


<strong>Overload</strong> relay trip curves<br />

Class 10A, 65AF<br />

MT-63/2H<br />

MT-63/3H<br />

MT-63/3K<br />

60<br />

40<br />

30<br />

20<br />

Cold starting<br />

60<br />

40<br />

30<br />

20<br />

Hot starting<br />

Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

2<br />

Tripping Time<br />

60<br />

40<br />

30<br />

20<br />

Tripping Time<br />

60<br />

40<br />

30<br />

20<br />

Second<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

Second<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

2<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

0.3<br />

1 2 3 4<br />

5 6 7 8 9 10 15<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

0.3<br />

1 2<br />

3 4 5 6 7 8 910<br />

15<br />

Multiple of current setting<br />

× ln[A]<br />

Multiple of current setting<br />

× ln[A]<br />

Class 20, 65AF<br />

MT-63/3D<br />

60<br />

Cold starting<br />

60<br />

Hot starting<br />

40<br />

40<br />

30<br />

30<br />

20<br />

20<br />

Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

2<br />

Tripping Time<br />

60<br />

40<br />

30<br />

20<br />

Tripping Time<br />

60<br />

40<br />

30<br />

20<br />

Second<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

Second<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

2<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

0.3<br />

1 2 3 4<br />

5 6 7 8 9 10 15<br />

0.3<br />

1 2<br />

3 4 5 6 7 8 910<br />

15<br />

Multiple of current setting<br />

× ln[A]<br />

Multiple of current setting<br />

× ln[A]<br />

114


Class 10A, 100AF<br />

MT-95/2H<br />

MT-95/3H<br />

MT-95/3K<br />

60<br />

40<br />

30<br />

20<br />

Cold starting<br />

60<br />

40<br />

30<br />

20<br />

Hot starting<br />

Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

2<br />

Tripping Time<br />

60<br />

40<br />

30<br />

20<br />

Tripping Time<br />

60<br />

40<br />

30<br />

20<br />

Second<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

Second<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

2<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

0.3<br />

1 2 3 4<br />

5 6 7 8 9 10 15<br />

0.3<br />

1 2<br />

3 4 5 6 7 8 910<br />

15<br />

Multiple of current setting<br />

× ln[A]<br />

Multiple of current setting<br />

× ln[A]<br />

Class 20, 100AF<br />

MT-95/3D<br />

60<br />

Cold starting<br />

60<br />

Hot starting<br />

40<br />

40<br />

30<br />

30<br />

20<br />

20<br />

Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

2<br />

Tripping Time<br />

60<br />

40<br />

30<br />

20<br />

Tripping Time<br />

60<br />

40<br />

30<br />

20<br />

Second<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

Second<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

2<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

0.3<br />

1 2 3 4<br />

5 6 7 8 9 10 15<br />

0.3<br />

1 2<br />

3 4 5 6 7 8 910<br />

15<br />

Multiple of current setting<br />

× ln[A]<br />

Multiple of current setting<br />

× ln[A]<br />

115


<strong>Overload</strong> relay trip curves<br />

Class 10A, 150AF<br />

MT-150/2H<br />

MT-150/3H<br />

MT-150/3K<br />

60<br />

40<br />

30<br />

20<br />

Cold starting<br />

60<br />

40<br />

30<br />

20<br />

Hot starting<br />

Tripping Time<br />

Second Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

60<br />

40<br />

30<br />

20<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

Tripping Time<br />

Second Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

60<br />

40<br />

30<br />

20<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

2<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

0.3<br />

1 2 3 4<br />

Multiple of current setting<br />

5 6 7 8 9 10 15<br />

× ln[A]<br />

0.3<br />

1 2 3 4 5 6 7 8 910 15<br />

Multiple of current setting<br />

× ln[A]<br />

Class 20, 150AF<br />

MT-150/3D<br />

60<br />

Cold starting<br />

60<br />

Hot starting<br />

40<br />

40<br />

30<br />

30<br />

20<br />

20<br />

Tripping Time<br />

Second Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

60<br />

40<br />

30<br />

20<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

Tripping Time<br />

Second Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

60<br />

40<br />

30<br />

20<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

2<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

0.3<br />

1 2 3 4<br />

Multiple of current setting<br />

5 6 7 8 9 10 15<br />

× ln[A]<br />

0.3<br />

1 2 3 4 5 6 7 8 910 15<br />

Multiple of current setting<br />

× ln[A]<br />

116


Class 10A, 225AF<br />

MT-225/2H<br />

MT-225/3H<br />

MT-225/3K<br />

60<br />

40<br />

30<br />

20<br />

Cold starting<br />

60<br />

40<br />

30<br />

20<br />

Hot starting<br />

Tripping Time<br />

Second Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

60<br />

40<br />

30<br />

20<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

Tripping Time<br />

Second Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

60<br />

40<br />

30<br />

20<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

2<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

0.3<br />

1 2 3 4<br />

Multiple of current setting<br />

5 6 7 8 9 10 15<br />

× ln[A]<br />

0.3<br />

1 2 3 4 5 6 7 8 910 15<br />

Multiple of current setting<br />

× ln[A]<br />

Class 20, 225AF<br />

MT-225/3D<br />

60<br />

Cold starting<br />

60<br />

Hot starting<br />

40<br />

40<br />

30<br />

30<br />

20<br />

20<br />

Tripping Time<br />

Second Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

60<br />

40<br />

30<br />

20<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

Tripping Time<br />

Second Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

60<br />

40<br />

30<br />

20<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

2<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

0.3<br />

1 2 3 4<br />

Multiple of current setting<br />

5 6 7 8 9 10 15<br />

× ln[A]<br />

0.3<br />

1 2 3 4 5 6 7 8 910 15<br />

Multiple of current setting<br />

× ln[A]<br />

117


<strong>Overload</strong> relay trip curves<br />

Class 10A, 400AF<br />

MT-400/2H<br />

MT-400/3H<br />

MT-400/3K<br />

60<br />

40<br />

30<br />

20<br />

Cold starting<br />

60<br />

40<br />

30<br />

20<br />

Hot starting<br />

Tripping Time<br />

Second Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

60<br />

40<br />

30<br />

20<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

Tripping Time<br />

Second Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

60<br />

40<br />

30<br />

20<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

2<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

0.3<br />

1 2 3 4<br />

Multiple of current setting<br />

5 6 7 8 9 10 15<br />

× ln[A]<br />

0.3<br />

1 2 3 4 5 6 7 8 910 15<br />

Multiple of current setting<br />

× ln[A]<br />

Class 20, 400AF<br />

MT-400/3D<br />

60<br />

Cold starting<br />

60<br />

Hot starting<br />

40<br />

40<br />

30<br />

30<br />

20<br />

20<br />

Tripping Time<br />

Second Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

60<br />

40<br />

30<br />

20<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

Tripping Time<br />

Second Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

60<br />

40<br />

30<br />

20<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

2<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

0.3<br />

1 2 3 4<br />

Multiple of current setting<br />

5 6 7 8 9 10 15<br />

× ln[A]<br />

0.3<br />

1 2 3 4 5 6 7 8 910 15<br />

Multiple of current setting<br />

× ln[A]<br />

118


Class 10A, 800AF<br />

MT-800/2H<br />

MT-800/3H<br />

MT-800/3K<br />

60<br />

40<br />

30<br />

20<br />

Cold starting<br />

60<br />

40<br />

30<br />

20<br />

Hot starting<br />

Tripping Time<br />

Second Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

60<br />

40<br />

30<br />

20<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

Tripping Time<br />

Second Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

60<br />

40<br />

30<br />

20<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

2<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

0.3<br />

1 2 3 4<br />

Multiple of current setting<br />

5 6 7 8 9 10 15<br />

× ln[A]<br />

0.3<br />

1 2 3 4 5 6 7 8 910 15<br />

Multiple of current setting<br />

× ln[A]<br />

Class 20, 800AF<br />

MT-800/3D<br />

60<br />

Cold starting<br />

60<br />

Hot starting<br />

40<br />

40<br />

30<br />

30<br />

20<br />

20<br />

Tripping Time<br />

Second Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

60<br />

40<br />

30<br />

20<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

Tripping Time<br />

Second Minute<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

60<br />

40<br />

30<br />

20<br />

10<br />

8<br />

6<br />

5<br />

4<br />

3<br />

2<br />

2<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

1<br />

0.8<br />

0.6<br />

0.5<br />

0.4<br />

0.3<br />

1 2 3 4<br />

Multiple of current setting<br />

5 6 7 8 9 10 15<br />

× ln[A]<br />

0.3<br />

1 2 3 4 5 6 7 8 910 15<br />

Multiple of current setting<br />

× ln[A]<br />

119


Type 2 Coordination (380/415V)<br />

415V<br />

HI type <strong>MMS</strong>, Susol MCCB<br />

Rated Operational Power Circuit Breaker <strong>Contactor</strong> Thermal <strong>Overload</strong> Relays Short Circuit<br />

kW<br />

Current [A]<br />

Breaking Capacity<br />

Rating Setting Range<br />

Type<br />

Type Type<br />

380V 400V 415V [A] [A] Ir [kA] Iq [kA]<br />

0.06 0.21 0.20 0.19 <strong>MMS</strong>-32HI 0.25 MC-6a MT-12 0.16~0.25 1 50<br />

0.09 0.32 0.30 0.29 <strong>MMS</strong>-32HI 0.4 MC-6a MT-12 0.25~0.4 1 50<br />

0.12 0.46 0.44 0.42 <strong>MMS</strong>-32HI 0.63 MC-6a MT-12 0.4~0.63 1 50<br />

0.18 0.63 0.60 0.58 <strong>MMS</strong>-32HI 0.63 MC-6a MT-12 0.4~0.63 1 50<br />

0.25 0.89 0.85 0.82 <strong>MMS</strong>-32HI 1 MC-6a MT-12 0.63~1 1 50<br />

0.37 1.16 1.10 1.06 <strong>MMS</strong>-32HI 1.6 MC-12a,12b MT-12 1~1.6 1 50<br />

0.55 1.6 1.5 1.4 <strong>MMS</strong>-32HI 1.6 MC-12a,12b MT-12 1~1.6 1 50<br />

0.75 2.0 1.9 1.8 <strong>MMS</strong>-32HI 2.5 MC-12a,12b MT-12 1.6~2.5 1 50<br />

1.1 2.8 2.7 2.6 <strong>MMS</strong>-32HI 4 MC-22b MT-32 2.5~4 1 50<br />

1.5 3.8 3.6 3.5 <strong>MMS</strong>-32HI 4 MC-22b MT-32 2.5~4 1 50<br />

2.2 5.2 4.9 4.7 <strong>MMS</strong>-32HI 6 MC-22b MT-32 4~6 1 50<br />

3.0 6.8 6.5 6.3 <strong>MMS</strong>-32HI 8 MC-40a MT-32 5~8 1 50<br />

4.0 8.9 8.5 8.2 <strong>MMS</strong>-32HI 10 MC-40a MT-32 6~9 1 50<br />

5.5 12.1 11.5 11.1 <strong>MMS</strong>-32HI 13 MC-40a MT-32 9~13 3 50<br />

7.5 16.3 15.5 14.9 <strong>MMS</strong>-32HI 17 MC-40a MT-32 12~18 3 50<br />

11.0 23.2 22.0 21.2 TD100 25 MC-50a MT-63 18~25 3 70<br />

15.0 31 29 28 TD100 32 MC-50a MT-63 24~36 3 70<br />

18.5 37 35 34 TD100 40 MC-50a MT-63 28~40 3 70<br />

22 43 41 40 TD100 50 MC-50a MT-63 34~50 3 70<br />

30 58 55 53 TD100 63 MC-65a MT-63 45~65 3 70<br />

37 69 66 64 TD100 80 MC-75a MT-95 54~75 5 70<br />

45 84 80 77 TD100 100 MC-85a MT-95 63~85 5 70<br />

55 - - 93 TD100 100 MC-100a MT-95 70~95 5 70<br />

120


415V<br />

H type <strong>MMS</strong>, Susol MCCB<br />

Rated Operational Power Circuit Breaker <strong>Contactor</strong> Thermal <strong>Overload</strong> Relays Short Circuit<br />

kW<br />

Current [A]<br />

Breaking Capacity<br />

Rating Setting Range<br />

Type<br />

Type Type<br />

380V 400V 415V [A] [A] Ir [kA] Iq [kA]<br />

0.06 0.21 0.20 0.19 <strong>MMS</strong>-32H 0.25 MC-6a MT-12 0.16~0.25 1 50<br />

0.09 0.32 0.30 0.29 <strong>MMS</strong>-32H 0.4 MC-6a MT-12 0.25~0.4 1 50<br />

0.12 0.46 0.44 0.42 <strong>MMS</strong>-32H 0.63 MC-6a MT-12 0.4~0.63 1 50<br />

0.18 0.63 0.60 0.58 <strong>MMS</strong>-32H 0.63 MC-6a MT-12 0.4~0.63 1 50<br />

0.25 0.89 0.85 0.82 <strong>MMS</strong>-32H 1 MC-6a MT-12 0.63~1 1 50<br />

0.37 1.16 1.10 1.06 <strong>MMS</strong>-32H 1.6 MC-12a,12b MT-12 1~1.6 1 50<br />

0.55 1.6 1.5 1.4 <strong>MMS</strong>-32H 1.6 MC-12a,12b MT-12 1~1.6 1 50<br />

0.75 2.0 1.9 1.8 <strong>MMS</strong>-32H 2.5 MC-12a,12b MT-12 1.6~2.5 1 50<br />

1.1 2.8 2.7 2.6 <strong>MMS</strong>-32H 4 MC-22b MT-32 2.5~4 1 50<br />

1.5 3.8 3.6 3.5 <strong>MMS</strong>-32H 4 MC-22b MT-32 2.5~4 1 50<br />

2.2 5.2 4.9 4.7 <strong>MMS</strong>-32H 6 MC-22b MT-32 4~6 1 50<br />

3.0 6.8 6.5 6.3 <strong>MMS</strong>-32H 8 MC-40a MT-32 5~8 1 50<br />

4.0 8.9 8.5 8.2 <strong>MMS</strong>-32H 10 MC-40a MT-32 6~9 1 50<br />

5.5 12.1 11.5 11.1 <strong>MMS</strong>-32H 13 MC-40a MT-32 9~13 3 50<br />

7.5 16.3 15.5 14.9 <strong>MMS</strong>-32H 17 MC-40a MT-32 12~18 3 50<br />

11.0 23.2 22.0 21.2 TD100 25 MC-50a MT-63 18~25 3 70<br />

15.0 31 29 28 TD100 32 MC-50a MT-63 24~36 3 70<br />

18.5 37 35 34 TD100 40 MC-50a MT-63 28~40 3 70<br />

22 43 41 40 TD100 50 MC-50a MT-63 34~50 3 70<br />

30 58 55 53 TD100 63 MC-65a MT-63 45~65 3 70<br />

37 69 66 64 TD100 80 MC-75a MT-95 54~75 5 70<br />

45 84 80 77 TD100 100 MC-85a MT-95 63~85 5 70<br />

55 - - 93 TD100 100 MC-100a MT-95 70~95 5 70<br />

121


Type 2 Coordination (380/415V)<br />

415V<br />

Susol MCCB<br />

Rated Operational Power Circuit Breaker <strong>Contactor</strong> Thermal <strong>Overload</strong> Relays Short Circuit<br />

kW<br />

Current [A]<br />

Breaking Capacity<br />

Rating Setting Range<br />

Type<br />

Type Type<br />

380V 400V 415V [A] [A] Ir [kA] Iq [kA]<br />

0.06 0.21 0.20 0.19 TS100 (1) 1.6 MC-6a MT-12 0.16~0.25 1 50<br />

0.09 0.32 0.30 0.29 TS100 (1) 1.6 MC-6a MT-12 0.25~0.4 1 50<br />

0.12 0.46 0.44 0.42 TS100 (1) 1.6 MC-6a MT-12 0.4~0.63 1 50<br />

0.18 0.63 0.60 0.58 TS100 (1) 1.6 MC-6a MT-12 0.4~0.63 1 50<br />

0.25 0.89 0.85 0.82 TS100 (1) 1.6 MC-6a MT-12 0.63~1 1 50<br />

0.37 1.16 1.10 1.06 TS100 (1) 1.6 MC-12a,12b MT-12 1~1.6 1 50<br />

0.55 1.6 1.5 1.4 TS100 (1) 1.6 MC-12a,12b MT-12 1~1.6 1 50<br />

0.75 2.0 1.9 1.8 TS100 (1) 1.6 MC-12a,12b MT-12 1.6~2.5 1 50<br />

1.1 2.8 2.7 2.6 TS100 (1) 3.2 MC-22b MT-32 2.5~4 1 50<br />

1.5 3.8 3.6 3.5 TS100 (1) 3.2 MC-22b MT-32 2.5~4 1 50<br />

2.2 5.2 4.9 4.7 TS100 (1) 3.2 MC-22b MT-32 4~6 1 50<br />

3.0 6.8 6.5 6.3 TS100 (1) 6.3 MC-40a MT-32 5~8 1 50<br />

4.0 8.9 8.5 8.2 TS100 (1) 6.3 MC-40a MT-32 6~9 1 50<br />

5.5 12.1 11.5 11.1 TS100 (1) 12 MC-40a MT-32 9~13 3 50<br />

7.5 16.3 15.5 14.9 TS100 (1) 12 MC-40a MT-32 12~18 3 50<br />

11.0 23.2 22.0 21.2 TD100 25 MC-50a MT-63 18~25 3 70<br />

15.0 31 29 28 TD100 32 MC-50a MT-63 24~36 3 70<br />

18.5 37 35 34 TD100 40 MC-50a MT-63 28~40 3 70<br />

22 43 41 40 TD100 50 MC-50a MT-63 34~50 3 70<br />

30 58 55 53 TD100 63 MC-65a MT-63 45~65 3 70<br />

37 69 66 64 TD100 80 MC-75a MT-95 54~75 5 70<br />

45 84 80 77 TD100 100 MC-85a MT-95 63~85 5 70<br />

55 - - 93 TD100 100 MC-100a MT-95 70~95 5 70<br />

Note) (1) This marks admit for motor protection MTU trip unit only.<br />

122


Type 2 Coordination (440V)<br />

440V<br />

Susol MCCB N-type<br />

Rated Operational Power Circuit Breaker <strong>Contactor</strong> Thermal <strong>Overload</strong> Relays Short Circuit<br />

kW<br />

Current [A]<br />

Breaking Capacity<br />

Rating Setting Range<br />

Type<br />

Type Type<br />

440V [A] [A] Ir [kA] Iq [kA]<br />

1.1 2.37 TD100N 16 MC-12b MT-32 2.5~4 1 50<br />

1.5 3.06 TD100N 16 MC-18b MT-32 2.5~4 1 50<br />

2.2 4.42 TD100N 16 MC-22b MT-32 4~6 1 50<br />

3 5.77 TD100N 16 MC-22b MT-32 5~8 1 50<br />

4 7.90 TD100N 16 MC-32a MT-32 6~9 1 50<br />

5.5 10.40 TD100N 16 MC-32a MT-32 9~13 3 50<br />

7.5 13.70 TD100N 20 MC-32a MT-32 12~18 3 50<br />

11 20.10 TD100N 32 MC-40a MT-32 18~25 3 50<br />

15 26.50 TD100N 40 MC-40a MT-32 22~32 3 50<br />

18.5 32.80 TS100N 40 MC-50a MT-63 28~40 3 50<br />

22 39.00 TS100N 50 MC-50a MT-63 34~50 3 50<br />

30 51.50 TS100N 63 MC-65a MT-63 45~65 3 50<br />

37 64.00 TS100N 80 MC-75a MT-95 54~75 5 50<br />

45 76.00 TS100N 100 MC-85a MT-95 63~85 5 50<br />

55 90.00 TS100N 100 MC-100a MT-95 70~95 5 50<br />

59 97.00 TS160N 100 MC-130a MT-150 80~105 5 50<br />

75 125 TS160N 160 MC-150a MT-150 110~150 10 50<br />

90 146 TS160N 160 MC-185a MT-225 120~185 10 50<br />

110 178 TS250N 200 MC-185a MT-225 160~240 10 50<br />

132 215 TS250N 250 MC-225a MT-225 160~240 10 65<br />

160 256 TS400N 300 MC-400a MT-400 200~330 18 65<br />

200 330 TS400N 400 MC-400a MT-400 260~400 18 65<br />

220 353 TS400N 400 MC-400a MT-400 260~400 18 65<br />

250 401 TS630N 500 MC-630a MT-800 260~400 18 65<br />

300 481 TS630N 500 MC-630a MT-800 400~630 18 65<br />

123


Type 2 Coordination (440V)<br />

440V<br />

Susol MCCB H-type<br />

Rated Operational Power Circuit Breaker <strong>Contactor</strong> Thermal <strong>Overload</strong> Relays Short Circuit<br />

kW<br />

Current [A]<br />

Breaking Capacity<br />

Rating Setting Range<br />

Type<br />

Type Type<br />

440V [A] [A] Ir [kA] Iq [kA]<br />

1.1 2.37 TD100H 16 MC-12b MT-32 2.5~4 1 50<br />

1.5 3.06 TD100H 16 MC-18b MT-32 2.5~4 1 50<br />

2.2 4.42 TD100H 16 MC-22b MT-32 4~6 1 50<br />

3 5.77 TD100H 16 MC-22b MT-32 5~8 1 50<br />

4 7.90 TD100H 16 MC-32a MT-32 6~9 1 50<br />

5.5 10.40 TD100H 16 MC-32a MT-32 9~13 3 50<br />

7.5 13.70 TD100H 20 MC-32a MT-32 12~18 3 70<br />

11 20.10 TD100H 32 MC-40a MT-32 18~25 3 70<br />

15 26.50 TD100H 40 MC-40a MT-32 22~32 3 70<br />

18.5 32.80 TS100H 40 MC-50a MT-63 28~40 3 70<br />

22 39.00 TS100H 50 MC-50a MT-63 34~50 3 70<br />

30 51.50 TS100H 63 MC-65a MT-63 45~65 3 70<br />

37 64.00 TS100H 80 MC-75a MT-95 54~75 5 70<br />

45 76.00 TS100H 100 MC-85a MT-95 63~85 5 70<br />

55 90.00 TS100H 100 MC-100a MT-95 70~95 5 70<br />

59 97.00 TS160H 100 MC-130a MT-150 80~105 5 70<br />

75 125 TS160H 160 MC-150a MT-150 110~150 10 70<br />

90 146 TS160H 160 MC-185a MT-225 120~185 10 70<br />

110 178 TS250H 200 MC-185a MT-225 160~240 10 70<br />

132 215 TS250H 250 MC-225a MT-225 160~240 10 70<br />

160 256 TS400H 300 MC-400a MT-400 200~330 18 85<br />

200 330 TS400H 400 MC-400a MT-400 260~400 18 85<br />

220 353 TS400H 400 MC-400a MT-400 260~400 18 85<br />

250 401 TS630H 500 MC-630a MT-800 260~400 18 85<br />

300 481 TS630H 500 MC-630a MT-800 400~630 18 100<br />

124


440V<br />

Susol MCCB L-type<br />

Rated Operational Power Circuit Breaker <strong>Contactor</strong> Thermal <strong>Overload</strong> Relays Short Circuit<br />

kW<br />

Current [A]<br />

Breaking Capacity<br />

Rating Setting Range<br />

Type<br />

Type Type<br />

440V [A] [A] Ir [kA] Iq [kA]<br />

1.1 2.37 TD100L 16 MC-12b MT-32 2.5~4 1 50<br />

1.5 3.06 TD100L 16 MC-18b MT-32 2.5~4 1 50<br />

2.2 4.42 TD100L 16 MC-22b MT-32 4~6 1 50<br />

3 5.77 TD100L 16 MC-22b MT-32 5~8 1 50<br />

4 7.90 TD100L 16 MC-32a MT-32 6~9 1 50<br />

5.5 10.40 TD100L 16 MC-32a MT-32 9~13 3 50<br />

7.5 13.70 TD100L 20 MC-32a MT-32 12~18 3 100<br />

11 20.10 TD100L 32 MC-40a MT-32 18~25 3 100<br />

15 26.50 TD100L 40 MC-40a MT-32 22~32 3 100<br />

18.5 32.80 TS100L 40 MC-50a MT-63 28~40 3 130<br />

22 39.00 TS100L 50 MC-50a MT-63 34~50 3 130<br />

30 51.50 TS100L 63 MC-65a MT-63 45~65 3 130<br />

37 64.00 TS100L 80 MC-75a MT-95 54~75 5 130<br />

45 76.00 TS100L 100 MC-85a MT-95 63~85 5 130<br />

55 90.00 TS100L 100 MC-100a MT-95 70~95 5 130<br />

59 97.00 TS160L 100 MC-130a MT-150 80~105 5 130<br />

75 125 TS160L 160 MC-150a MT-150 110~150 10 130<br />

90 146 TS160L 160 MC-185a MT-225 120~185 10 130<br />

110 178 TS250L 200 MC-185a MT-225 160~240 10 130<br />

132 215 TS250L 250 MC-225a MT-225 160~240 10 130<br />

160 256 TS400L 300 MC-400a MT-400 200~330 18 130<br />

200 330 TS400L 400 MC-400a MT-400 260~400 18 130<br />

220 353 TS400L 400 MC-400a MT-400 260~400 18 130<br />

250 401 TS630L 500 MC-630a MT-800 260~400 18 130<br />

300 481 TS630L 500 MC-630a MT-800 400~630 18 130<br />

125


Type 2 Coordination (440V)<br />

440V<br />

Metasol MCCB N-type<br />

Rated Operational Power Circuit Breaker <strong>Contactor</strong> Thermal <strong>Overload</strong> Relays Short Circuit<br />

kW<br />

Current [A]<br />

Breaking Capacity<br />

Rating Setting Range<br />

Type<br />

Type Type<br />

440V [A] [A] Ir [kA] Iq [kA]<br />

1.1 2.37 ABN53c 15 MC-12b MT-32 2.5~4 1 14<br />

1.5 3.06 ABN53c 15 MC-18b MT-32 2.5~4 1 14<br />

2.2 4.42 ABN53c 15 MC-22b MT-32 4~6 1 14<br />

3.0 5.77 ABN53c 15 MC-22b MT-32 5~8 1 14<br />

4.0 7.90 ABN53c 15 MC-32a MT-32 6~9 1 14<br />

5.5 10.40 ABN53c 15 MC-32a MT-32 9~13 3 14<br />

7.5 13.70 ABN53c 20 MC-32a MT-32 12~18 3 14<br />

11.0 20.10 ABN103c 30 MC-40a MT-32 18~25 3 18<br />

15.0 26.50 ABN103c 40 MC-40a MT-32 22~32 3 18<br />

18.5 32.80 ABN103c 40 MC-50a MT-63 28~40 3 18<br />

22.0 39.00 ABN103c 50 MC-50a MT-63 34~50 3 18<br />

30.0 51.50 ABN103c 75 MC-65a MT-63 45~65 3 18<br />

37.0 64.00 ABN103c 75 MC-75a MT-95 54~75 5 18<br />

45.0 76.00 ABN103c 100 MC-85a MT-95 63~85 5 18<br />

55.0 90.00 ABN103c 100 MC-100a MT-95 70~95 5 18<br />

59.0 97.00 ABN103c 100 MC-130a MT-150 80~105 5 18<br />

75.0 125 ABN203c 150 MC-150a MT-150 110~150 10 26<br />

90.0 146 ABN203c 200 MC-185a MT-225 120~185 10 26<br />

110.0 178 ABN203c 200 MC-185a MT-225 160~240 10 26<br />

132.0 215 ABN203c 250 MC-225a MT-225 160~240 10 26<br />

160.0 256 ABN403c 300 MC-400a MT-400 200~330 18 37<br />

200.0 330 ABN403c 400 MC-400a MT-400 260~400 18 37<br />

220.0 353 ABN403c 400 MC-400a MT-400 260~400 18 37<br />

250.0 401 ABN803c 500 MC-630a MT-800 260~400 18 37<br />

300.0 481 ABN803c 500 MC-630a MT-800 400~630 18 37<br />

126


Rated UL 508 Combination motor controller type-C<br />

Combination motor controller function<br />

Type-C<br />

Disconnect<br />

Branch circuit<br />

protect<br />

Motor control<br />

Inverse-Time<br />

Circuit Breaker<br />

MC<br />

(Magnetic <strong>Contactor</strong>)<br />

Motor overload<br />

protect<br />

OLR<br />

(<strong>Overload</strong> Relay)<br />

240V<br />

Susol UL MCCB C-type<br />

CB MC OLR kA@240V Maximum HP Maximum NEC FLC [A]<br />

UTE100E<br />

50 3<br />

MC-6a<br />

MT-12 0.1~10A<br />

UTE100N 65 3<br />

UTE100E<br />

50 3<br />

MC-9a<br />

MT-12 0.1~10A<br />

UTE100N 65 3<br />

UTE100E<br />

50 5<br />

MC-12a<br />

MT-12 0.1~18A<br />

UTE100N 65 5<br />

UTE100E<br />

50 7.5<br />

UTE100N 65 7.5<br />

MC-18a<br />

MT-12 0.1~18A<br />

UTS150N 65 7.5<br />

UTS150L 100 7.5<br />

UTE100E<br />

50 3<br />

MC-9b<br />

MT-32 0.1~10A<br />

UTE100N 65 3<br />

UTE100E<br />

50 5<br />

MC-12b<br />

MT-32 0.1~18A<br />

UTE100N 65 5<br />

UTE100E<br />

50 7.5<br />

UTE100N 65 7.5<br />

MC-18b<br />

MT-32 0.1~25A<br />

UTS150N 65 7.5<br />

UTS150L 100 7.5<br />

UTE100E<br />

50 10<br />

UTE100N 65 10<br />

MC-22b<br />

MT-32 0.1~32A<br />

UTS150N 65 10<br />

UTS150L 100 10<br />

UTE100E<br />

50 10<br />

UTE100N 65 10<br />

MC-32a<br />

MT-32 0.1~32A<br />

UTS150N 65 10<br />

UTS150L 100 10<br />

UTE100E<br />

50 15<br />

UTE100N 65 15<br />

MC-40a<br />

MT-32 0.1~40A<br />

UTS150N 65 15<br />

UTS150L 100 15<br />

9.6<br />

15.2<br />

22<br />

9.6<br />

15.2<br />

22<br />

28<br />

28<br />

42<br />

127


Rated UL 508 Combination motor controller type-C<br />

240V<br />

Susol UL MCCB C-type<br />

CB MC OLR kA@240V Maximum HP Maximum NEC FLC [A]<br />

UTE100E<br />

50 3<br />

MC-6a<br />

MT-12 0.1~10A<br />

UTE100N 65 3<br />

UTE100E<br />

50 3<br />

MC-9a<br />

MT-12 0.1~10A<br />

UTE100N 65 3<br />

9.6<br />

UTE100E<br />

50 5<br />

MC-12a<br />

MT-12 0.1~18A<br />

UTE100N 65 5<br />

15.2<br />

UTE100E<br />

50 7.5<br />

UTE100N 65 7.5<br />

MC-18a<br />

MT-12 0.1~18A<br />

UTS150N 65 7.5<br />

22<br />

UTS150L 100 7.5<br />

UTE100E<br />

50 3<br />

MC-9b<br />

MT-32 0.1~10A<br />

UTE100N 65 3<br />

9.6<br />

UTE100E<br />

50 5<br />

MC-12b<br />

MT-32 0.1~18A<br />

UTE100N 65 5<br />

15.2<br />

UTE100E<br />

50 7.5<br />

UTE100N 65 7.5<br />

MC-18b<br />

MT-32 0.1~25A<br />

UTS150N 65 7.5<br />

22<br />

UTS150L 100 7.5<br />

UTE100E<br />

50 10<br />

UTE100N 65 10<br />

MC-22b<br />

MT-32 0.1~32A<br />

UTS150N 65 10<br />

28<br />

UTS150L 100 10<br />

UTE100E<br />

50 10<br />

UTE100N 65 10<br />

MC-32a<br />

MT-32 0.1~32A<br />

UTS150N 65 10<br />

28<br />

UTS150L 100 10<br />

UTE100E<br />

50 15<br />

UTE100N 65 15<br />

MC-40a<br />

MT-32 0.1~40A<br />

UTS150N 65 15<br />

42<br />

UTS150L 100 15<br />

UTE100E<br />

50 25<br />

UTE100N 65 25<br />

MC-50a MT-63 4~65A<br />

UTS150N 65 25<br />

65<br />

UTS150L 100 25<br />

UTE100E<br />

50 30<br />

UTE100N 65 30<br />

MC-65a MT-63 4~65A<br />

UTS150N 65 30<br />

80<br />

UTS150L 100 30<br />

UTS150N<br />

65 30<br />

MC-75a MT-95 7~95A<br />

UTS150L 100 30<br />

80<br />

UTS150N<br />

65 40<br />

MC-85a MT-95 7~100A<br />

UTS150L 100 40<br />

104<br />

UTS150N<br />

65 40<br />

MC-100a MT-95 7~100A<br />

UTS150L 100 40<br />

104<br />

UTS150N<br />

65 40<br />

MC-130a MT-150 34~130A<br />

UTS150L 100 40<br />

104<br />

UTS150N<br />

65 50<br />

UTS150L 100 50<br />

MC-150a MT-150 34~130A<br />

UTS250N 65 50<br />

130<br />

UTS250L 100 50<br />

UTS250N<br />

65 60<br />

UTS250L 100 60<br />

MC-185a MT-225 65~185A<br />

UTS400N 65 60<br />

154<br />

UTS400L 100 60<br />

UTS400N<br />

65 75<br />

UTS400L 100 75<br />

MC-225a MT-225 65~240A<br />

UTS250N 65 75<br />

192<br />

UTS250L 100 75<br />

UTS400N<br />

65 100<br />

MC-265a MT-400 85~330A<br />

UTS400L 100 100<br />

248<br />

UTS400N<br />

65 100<br />

MC-330a MT-400 85~330A<br />

UTS400L 100 100<br />

248<br />

UTS600N<br />

65 150<br />

MC-400a MT-400 85~400A<br />

UTS600L 100 150<br />

360<br />

UTS800L MC-500a MT-800 200~600A 100 200 480<br />

UTS800L MC-630a MT-800 200~800A 100 250 604<br />

128


Rated UL 508 Combination motor controller type-C<br />

480V<br />

Susol UL MCCB C-type<br />

CB MC OLR kA@480V Maximum HP Maximum NEC FLC [A]<br />

UTE100E<br />

480 25<br />

MC-6a<br />

MT-12 0.1~10A<br />

UTE100N 480 35<br />

UTE100E<br />

480 25<br />

MC-9a<br />

MT-12 0.1~10A<br />

UTE100N 480 35<br />

7.6<br />

UTE100E<br />

480 25<br />

MC-12a<br />

MT-12 0.1~13A<br />

UTE100N 480 35<br />

11<br />

UTE100E<br />

480 25<br />

UTE100N 480 35<br />

UTS150N MC-18a<br />

MT-12 0.1~18A<br />

480 35<br />

14<br />

UTS150H 480 65<br />

UTS150L 480 100<br />

UTE100E<br />

480 25<br />

MC-9b<br />

MT-32 0.1~10A<br />

UTE100N 480 35<br />

7.6<br />

UTE100E<br />

480 25<br />

MC-12b<br />

MT-32 0.1~13A<br />

UTE100N 480 35<br />

11<br />

UTE100E<br />

480 25<br />

MC-18b<br />

MT-32 0.1~18A<br />

UTE100N 480 35<br />

14<br />

UTE100E<br />

480 25<br />

UTE100N 480 35<br />

UTS150N MC-22b<br />

MT-32 0.1~25A<br />

480 35<br />

21<br />

UTS150H 480 65<br />

UTS150L 480 100<br />

UTE100E<br />

480 25<br />

UTE100N 480 35<br />

UTS150N MC-32a<br />

MT-32 0.1~32A<br />

480 35<br />

27<br />

UTS150H 480 65<br />

UTS150L 480 100<br />

UTE100E<br />

480 25<br />

UTE100N 480 35<br />

UTS150N MC-40a<br />

MT-32 0.1~40A<br />

480 35<br />

40<br />

UTS150H 480 65<br />

UTS150L 480 100<br />

UTE100E<br />

480 25<br />

UTE100N 480 35<br />

UTS150N MC-50a MT-63 4~65A<br />

480 35<br />

52<br />

UTS150H 480 65<br />

UTS150L 480 100<br />

UTE100E<br />

480 25<br />

UTE100N 480 35<br />

UTS150N MC-65a MT-63 4~65A<br />

480 35<br />

65<br />

UTS150H 480 65<br />

UTS150L 480 100<br />

UTS150N<br />

480 35<br />

UTS150H MC-75a MT-95 7~75A<br />

480 65<br />

65<br />

UTS150L 480 100<br />

UTS150N<br />

480 35<br />

UTS150H MC-85a MT-95 7~85A<br />

480 65<br />

77<br />

UTS150L 480 100<br />

UTS150N<br />

480 35<br />

UTS150H MC-100a MT-95 7~100A<br />

480 65<br />

96<br />

UTS150L 480 100<br />

UTS150N<br />

480 35<br />

UTS150H MC-130a MT-150 34~130A<br />

480 65<br />

96<br />

UTS150L 480 100<br />

UTS150N<br />

480 35<br />

UTS150H 480 65<br />

UTS150L 480 100<br />

MC-150a MT-150 34~130A<br />

UTS250N 480 35<br />

124<br />

UTS250H 480 65<br />

UTS250L 480 100<br />

UTS250N<br />

480 35<br />

UTS250H 480 65<br />

UTS250L 480 100<br />

MC-185a MT-225 65~185A<br />

UTS400N 480 35<br />

156<br />

UTS400H 480 65<br />

UTS400L 480 100<br />

UTS250N<br />

480 35<br />

UTS250H 480 65<br />

UTS250L 480 100<br />

MC-225a MT-225 65~240A<br />

UTS400N 480 35<br />

180<br />

UTS400H 480 65<br />

UTS400L 480 100<br />

UTS400N<br />

480 35<br />

UTS400H MC-265a MT-400 85~330A<br />

480 65<br />

240<br />

UTS400L 480 100<br />

UTS400N<br />

480 35<br />

UTS400H MC-330a MT-400 85~330A<br />

480 65<br />

302<br />

UTS400L 480 100<br />

UTS600N<br />

480 35<br />

UTS600H MC-400a MT-400 85~400A<br />

480 65<br />

361<br />

UTS600L 480 100<br />

UTS800H<br />

480 65<br />

MC-500a MT-800 200~600A<br />

UTS800L 480 100<br />

477<br />

UTS800H<br />

MC-630a<br />

480 65<br />

MT-800 200~800A<br />

UTS800L MC-630a 480 100<br />

590<br />

129


Rated UL 508 Combination motor controller type-C<br />

600V<br />

Susol UL MCCB C-type<br />

130<br />

CB MC OLR kA@600V Maximum HP Maximum NEC FLC [A]<br />

UTE100E<br />

600Y/347 14<br />

MC-6a<br />

MT-12 0.1~10A<br />

UTE100N 600Y/347 18<br />

UTE100E<br />

600Y/347 14<br />

MC-9a<br />

MT-12 0.1~10A<br />

UTE100N 600Y/347 18<br />

9<br />

UTE100E<br />

600Y/347 14<br />

MC-12a<br />

MT-12 0.1~13A<br />

UTE100N 600Y/347 18<br />

11<br />

UTE100E<br />

600Y/347 14<br />

UTE100N 600Y/347 18<br />

UTS150N MC-18a<br />

MT-12 0.1~18A<br />

600 18<br />

17<br />

UTS150H 600 35<br />

UTS150L 600 50<br />

UTE100E<br />

600Y/347 14<br />

MC-9b<br />

MT-32 0.1~10A<br />

UTE100N 600Y/347 18<br />

9<br />

UTE100E<br />

600Y/347 14<br />

MC-12b<br />

MT-32 0.1~13A<br />

UTE100N 600Y/347 18<br />

11<br />

UTE100E<br />

600Y/347 14<br />

MC-18b<br />

MT-32 0.1~18A<br />

UTE100N 600Y/347 18<br />

17<br />

UTE100E<br />

600Y/347 14<br />

UTE100N 600Y/347 18<br />

UTS150N MC-22b<br />

MT-32 0.1~25A<br />

600 18<br />

22<br />

UTS150H 600 35<br />

UTS150L 600 50<br />

UTE100E<br />

600Y/347 14<br />

UTE100N 600Y/347 18<br />

UTS150N MC-32a<br />

MT-32 0.1~32A<br />

600 18<br />

27<br />

UTS150H 600 35<br />

UTS150L 600 50<br />

UTE100E<br />

600Y/347 14<br />

UTE100N 600Y/347 18<br />

UTS150N MC-40a<br />

MT-32 0.1~32A<br />

600 18<br />

32<br />

UTS150H 600 35<br />

UTS150L 600 50<br />

UTE100E<br />

600Y/347 14<br />

UTE100N 600Y/347 18<br />

UTS150N MC-50a MT-63 4~65A<br />

600 18<br />

52<br />

UTS150H 600 35<br />

UTS150L 600 50<br />

UTE100E<br />

600Y/347 14<br />

UTE100N 600Y/347 18<br />

UTS150N MC-65a MT-63 4~65A<br />

600 18<br />

62<br />

UTS150H 600 35<br />

UTS150L 600 50<br />

UTS150N<br />

600 18<br />

UTS150H MC-75a MT-95 7~75A<br />

600 35<br />

62<br />

UTS150L 600 50<br />

UTS150N<br />

600 18<br />

UTS150H MC-85a MT-95 7~85A<br />

600 35<br />

77<br />

UTS150L 600 50<br />

UTS150N<br />

600 18<br />

UTS150H MC-100a MT-95 7~85A<br />

600 35<br />

77<br />

UTS150L 600 50<br />

UTS150N<br />

600 18<br />

UTS150H MC-130a MT-150 34~85A<br />

600 35<br />

77<br />

UTS150L 600 50<br />

UTS150N<br />

600 18<br />

UTS150H MC-150a MT-150 34~85A<br />

600 35<br />

77<br />

UTS150L 600 50<br />

UTS250N<br />

600 18<br />

UTS250H 600 35<br />

UTS250L 600 50<br />

MC-185a MT-150 65~185A<br />

UTS400N 600 18<br />

125<br />

UTS400H 600 35<br />

UTS400L 600 50<br />

UTS250N<br />

600 18<br />

UTS250H 600 35<br />

UTS250L 600 50<br />

MC-225a MT-225 65~185A<br />

UTS400N 600 18<br />

144<br />

UTS400H 600 35<br />

UTS400L 600 50<br />

UTS400N<br />

600 18<br />

UTS400H MC-265a MT-400 85~240A<br />

600 35<br />

192<br />

UTS400L 600 50<br />

UTS400N<br />

600 18<br />

UTS400H MC-330a MT-400 85~330A<br />

600 35<br />

242<br />

UTS400L 600 50<br />

UTS600N<br />

600 18<br />

UTS600H MC-400a MT-400 85~400A<br />

600 35<br />

289<br />

UTS600L 600 50<br />

UTS800H<br />

600 35<br />

MC-500a MT-800 200~400A<br />

UTS800L 600 50<br />

382<br />

UTS800H<br />

600 35<br />

MC-630a MT-800 200~600A<br />

UTS800L 600 50<br />

472


Rated UL 508 Combination motor controller type-D<br />

Combination motor controller function<br />

Type-D<br />

Disconnect<br />

Branch circuit<br />

protect<br />

Motor control<br />

Instantaneours-Tirp<br />

Circuit Breaker<br />

MC<br />

(Magnetic <strong>Contactor</strong>)<br />

Motor overload<br />

protect<br />

OLR<br />

(<strong>Overload</strong> Relay)<br />

240V<br />

Susol UL MCCB D-type<br />

CB MC OLR kA@240V Maximum HP Maximum NEC FLC [A]<br />

UTS150L MCP MC-6a MT-12 0.1~10A 100 3 9.6<br />

UTS150L MCP MC-9a MT-12 0.1~10A 100 3 9.6<br />

UTS150L MCP MC-12a MT-12 0.1~18A 100 5 15.2<br />

UTS150L MCP MC-18a MT-12 0.1~18A 100 7.5 22<br />

UTS150L MCP MC-9b MT-32 0.1~10A 100 3 9.6<br />

UTS150L MCP MC-12b MT-32 0.1~18A 100 5 15.2<br />

UTS150L MCP MC-18b MT-32 0.1~25A 100 7.5 22<br />

UTS150L MCP MC-22b MT-32 0.1~32A 100 10 28<br />

UTS150L MCP MC-32a MT-32 0.1~32A 100 10 28<br />

UTS150L MCP MC-40a MT-32 0.1~40A 100 15 42<br />

UTS150L MCP MC-50a MT-63 4~65A 100 25 65<br />

UTS150L MCP MC-65a MT-63 4~65A 100 30 80<br />

UTS150L MCP MC-75a MT-95 7~95A 100 30 80<br />

UTS150L MCP MC-85a MT-95 7~100A 100 40 104<br />

UTS150L MCP MC-100a MT-95 7~100A 100 40 104<br />

UTS150L MCP MC-130a MT-150 34~130A 100 40 104<br />

UTS250L MCP MC-150a MT-150 34~130A 100 50 130<br />

UTS250L MCP MC-185a MT-225 65~160A 100 60 154<br />

UTS400L MCP MC-185a MT-225 65~185A 100 60 154<br />

UTS250L MCP MC-225a MT-225 65~240A 100 75 192<br />

UTS400L MCP MC-225a MT-225 65~240A 100 75 192<br />

UTS400L MCP MC-265a MT-400 85~330A 100 100 248<br />

UTS400L MCP MC-330a MT-400 85~330A 100 100 248<br />

UTS600L MCP MC-400a MT-400 85~400A 100 150 360<br />

UTS800L MCP MC-500a MT-800 200~600A 100 200 480<br />

UTS800L MCP MC-630a MT-800 200~800A 100 250 604<br />

131


Rated UL 508 Combination motor controller type-D<br />

480V<br />

Susol UL MCCB D-type<br />

CB MC OLR kA@400V Maximum HP Maximum NEC FLC [A]<br />

UTS150L MCP MC-6a MT-12 0.1~10A 65 5 7.6<br />

UTS150L MCP MC-9a MT-12 0.1~10A 65 5 7.6<br />

UTS150L MCP MC-12a MT-12 0.1~13A 65 7.5 11<br />

UTS150L MCP MC-18a MT-12 0.1~18A 65 10 14<br />

UTS150L MCP MC-9b MT-32 0.1~10A 65 5 7.6<br />

UTS150L MCP MC-12b MT-32 0.1~13A 65 7.5 11<br />

UTS150L MCP MC-18b MT-32 0.1~18A 65 10 14<br />

UTS150L MCP MC-22b MT-32 0.1~25A 65 15 21<br />

UTS150L MCP MC-32a MT-32 0.1~32A 65 20 27<br />

UTS150L MCP MC-40a MT-32 0.1~40A 65 20 40<br />

UTS150H MCP MC-50a MT-63 4~65A 65 40 52<br />

UTS150L MCP MC-50a MT-63 4~65A 100 40 52<br />

UTS150H MCP MC-65a MT-63 4~65A 65 50 65<br />

UTS150L MCP MC-65a MT-63 4~65A 100 50 65<br />

UTS150H MCP MC-75a MT-95 7~75A 65 50 65<br />

UTS150L MCP MC-75a MT-95 7~75A 100 50 65<br />

UTS150H MCP MC-85a MT-95 7~85A 65 60 77<br />

UTS150L MCP MC-85a MT-95 7~85A 100 60 77<br />

UTS150H MCP MC-100a MT-95 7~100A 65 75 96<br />

UTS150L MCP MC-100a MT-95 7~100A 100 75 96<br />

UTS150H MCP MC-130a MT-150 34~130A 65 75 96<br />

UTS150L MCP MC-130a MT-150 34~130A 100 75 96<br />

UTS250H MCP MC-150a MT-150 34~130A 65 100 124<br />

UTS250L MCP MC-150a MT-150 34~130A 100 100 124<br />

UTS250H MCP MC-185a MT-225 65~185A 65 125 156<br />

UTS250L MCP MC-185a MT-225 65~185A 85 125 156<br />

UTS400H MCP MC-185a MT-225 65~185A 65 125 156<br />

UTS400L MCP MC-185a MT-225 65~185A 100 125 156<br />

UTS250H MCP MC-225a MT-225 65~240A 65 150 180<br />

UTS250L MCP MC-225a MT-225 65~240A 85 150 180<br />

UTS400H MCP MC-225a MT-225 65~240A 65 150 180<br />

UTS400L MCP MC-225a MT-225 65~240A 100 150 180<br />

UTS400H MCP MC-265a MT-400 85~330A 65 200 240<br />

UTS400L MCP MC-265a MT-400 85~330A 100 200 240<br />

UTS400H MCP MC-330a MT-400 85~330A 65 200 240<br />

UTS400L MCP MC-330a MT-400 85~330A 100 200 240<br />

UTS600H MCP MC-400a MT-400 85~400A 65 300 361<br />

UTS600L MCP MC-400a MT-400 85~400A 100 300 361<br />

UTS800L MCP MC-500a MT-800 200~600A 100 400 477<br />

UTS800L MCP MC-630a MT-800 200~800A 100 500 590<br />

132


Rated UL 508 Combination motor controller type-D<br />

600V<br />

Susol UL MCCB D-type<br />

CB MC OLR kA@600V Maximum HP Maximum NEC FLC [A]<br />

UTS150L MCP MC-6a MT-12 0.1~10A 25 7.5 9<br />

UTS150L MCP MC-9a MT-12 0.1~10A 25 7.5 9<br />

UTS150L MCP MC-12a MT-12 0.1~13A 25 10 11<br />

UTS150L MCP MC-18a MT-12 0.1~18A 25 15 17<br />

UTS150L MCP MC-9b MT-32 0.1~10A 25 7.5 9<br />

UTS150L MCP MC-12b MT-32 0.1~13A 25 10 11<br />

UTS150L MCP MC-18b MT-32 0.1~18A 25 15 17<br />

UTS150L MCP MC-22b MT-32 0.1~25A 25 20 22<br />

UTS150L MCP MC-32a MT-32 0.1~32A 25 25 27<br />

UTS150L MCP MC-40a MT-32 0.1~32A 25 25 32<br />

UTS150H MCP MC-50a MT-63 4~65A 25 50 52<br />

UTS150L MCP MC-50a MT-63 4~65A 50 50 62<br />

UTS150H MCP MC-65a MT-63 4~65A 25 60 62<br />

UTS150L MCP MC-65a MT-63 4~65A 50 60 62<br />

UTS150H MCP MC-75a MT-95 7~75A 25 60 77<br />

UTS150L MCP MC-75a MT-95 7~75A 50 60 77<br />

UTS150H MCP MC-85a MT-95 7~85A 25 75 77<br />

UTS150L MCP MC-85a MT-95 7~85A 50 75 77<br />

UTS150H MCP MC-100a MT-95 7~85A 25 75 77<br />

UTS150L MCP MC-100a MT-95 7~85A 50 75 77<br />

UTS150H MCP MC-130a MT-150 65~185A 25 75 77<br />

UTS150L MCP MC-130a MT-150 65~185A 50 75 77<br />

UTS150H MCP MC-150a MT-150 65~185A 25 75 77<br />

UTS150L MCP MC-150a MT-150 65~185A 50 75 77<br />

UTS250H MCP MC-185a MT-225 65~185A 25 125 125<br />

UTS250L MCP MC-185a MT-225 65~185A 50 125 125<br />

UTS400H MCP MC-185a MT-225 65~185A 25 125 125<br />

UTS400L MCP MC-185a MT-225 65~185A 50 125 125<br />

UTS250H MCP MC-225a MT-225 65~185A 25 150 144<br />

UTS250L MCP MC-225a MT-225 65~185A 50 150 144<br />

UTS400H MCP MC-225a MT-225 65~185A 25 150 144<br />

UTS400L MCP MC-225a MT-225 65~185A 50 150 144<br />

UTS400H MCP MC-265a MT-400 85~240A 25 200 192<br />

UTS400L MCP MC-265a MT-400 85~240A 50 200 192<br />

UTS400H MCP MC-330a MT-400 85~330A 25 200 242<br />

UTS400L MCP MC-330a MT-400 85~330A 50 200 242<br />

UTS600H MCP MC-400a MT-400 85~400A 25 300 289<br />

UTS600L MCP MC-400a MT-400 85~400A 50 300 289<br />

UTS800L MCP MC-500a MT-800 200~400A 50 400 382<br />

UTS800L MCP MC-630a MT-800 200~600A 50 500 472<br />

133


Rated UL 508 combination motor controller Type-F<br />

Combination motor controller function<br />

Type-F<br />

Disconnect<br />

Branch circuit<br />

protect<br />

Manual Self-<br />

Protected<br />

Combination<br />

Controller<br />

Motor control<br />

MC<br />

(Magnetic <strong>Contactor</strong>)<br />

Motor overload<br />

protect<br />

32AF Rotary operation, High interruption<br />

Manual<br />

Self-Protected<br />

Adjustment<br />

range (A)<br />

Short circuit rating (kA)<br />

MC (Applied contactor)<br />

240V 480Y/277V 600Y/347V Metasol<br />

<strong>MMS</strong>-32H-0.16 0.1~0.16 100 65 25 MC-6a/MC-9a/MC-9b<br />

<strong>MMS</strong>-32H-0.25 0.16~0.25 100 65 25 MC-6a/MC-9a/MC-9b<br />

<strong>MMS</strong>-32H-0.4 0.25~0.4 100 65 25 MC-6a/MC-9a/MC-9b<br />

<strong>MMS</strong>-32H-0.63 0.4~0.63 100 65 25 MC-6a/MC-9a/MC-9b<br />

<strong>MMS</strong>-32H-1 0.63~1 100 65 25 MC-6a/MC-9a/MC-9b<br />

<strong>MMS</strong>-32H-1.6 1~1.6 100 65 25 MC-6a/MC-9a/MC-9b<br />

<strong>MMS</strong>-32H-2.5 1.6~2.5 100 65 25 MC-12a/MC-12b<br />

<strong>MMS</strong>-32H-4 2.5~4 100 65 25 MC-12a/MC-12b<br />

<strong>MMS</strong>-32H-6 4~6 100 65 25 MC-18a/MC-18b<br />

<strong>MMS</strong>-32H-8 5~8 100 65 10 MC-18a/MC-18b<br />

<strong>MMS</strong>-32H-10 6~10 100 65 10 MC-18a/MC-18b<br />

<strong>MMS</strong>-32H-13 9~13 100 65 10 MC-22b/MC-25a<br />

<strong>MMS</strong>-32H-17 11~17 100 30 10 MC-22b/MC-25a<br />

<strong>MMS</strong>-32H-22 14~22 100 30 10 MC-22b/MC-25a<br />

<strong>MMS</strong>-32H-26 18~26 100 30 10 MC-32a<br />

<strong>MMS</strong>-32H-32 22~32 100 30 10 MC-32a<br />

<strong>MMS</strong>-32H-40 28~40 100 30 10 MC-35a/MC-40a<br />

134


Rated UL 508 combination motor controller Type-F<br />

Combination motor controller function<br />

Type-F<br />

Disconnect<br />

Branch circuit<br />

protect<br />

Manual Self-<br />

Protected<br />

Combination<br />

Controller<br />

Motor control<br />

MC<br />

(Magnetic <strong>Contactor</strong>)<br />

Motor overload<br />

protect<br />

63AF Rotary operation, standard interruption<br />

Manual<br />

Self-Protected<br />

Adjustment<br />

range (A)<br />

Short circuit rating (kA)<br />

MC (Applied contactor)<br />

240V 480Y/277V 600Y/347V Metasol<br />

<strong>MMS</strong>-63S-10 6~10 100 50 10 MC-50a<br />

<strong>MMS</strong>-63S-13 9~13 100 50 10 MC-50a<br />

<strong>MMS</strong>-63S-17 11~17 100 40 10 MC-50a<br />

<strong>MMS</strong>-63S-22 14~22 100 40 10 MC-50a<br />

<strong>MMS</strong>-63S-26 18~26 100 40 10 MC-50a<br />

<strong>MMS</strong>-63S-32 22~32 100 40 10 MC-50a<br />

<strong>MMS</strong>-63S-40 28~40 100 40 10 MC-50a<br />

<strong>MMS</strong>-63S-40 28~40 100 40 10 MC-50a<br />

<strong>MMS</strong>-63S-50 34~50 100 40 10 MC-50a<br />

<strong>MMS</strong>-63S-63 45~63 100 40 10 MC-65a<br />

<strong>MMS</strong>-63S-65 47~65 100 40 10 MC-65a<br />

63AF Rotary operation, High interruption<br />

Manual<br />

Self-Protected<br />

Adjustment<br />

range (A)<br />

Short circuit rating (kA)<br />

MC (Applied contactor)<br />

240V 480Y/277V 600Y/347V Metasol<br />

<strong>MMS</strong>-63H-10 6~10 100 65 25 MC-50a<br />

<strong>MMS</strong>-63H-13 9~13 100 65 25 MC-50a<br />

<strong>MMS</strong>-63H-17 11~17 100 50 10 MC-50a<br />

<strong>MMS</strong>-63H-22 14~22 100 50 10 MC-50a<br />

<strong>MMS</strong>-63H-26 18~26 100 50 10 MC-50a<br />

<strong>MMS</strong>-63H-32 22~32 100 50 10 MC-50a<br />

<strong>MMS</strong>-63H-40 28~40 100 50 10 MC-50a<br />

<strong>MMS</strong>-63H-50 34~50 100 50 10 MC-50a<br />

<strong>MMS</strong>-63H-63 45~63 100 50 10 MC-50a<br />

<strong>MMS</strong>-63H-65 47~65 100 40 10 MC-65a<br />

135


Rated UL 508 combination motor controller Type-F<br />

Combination motor controller function<br />

Type-F<br />

Disconnect<br />

Branch circuit<br />

protect<br />

Manual Self-<br />

Protected<br />

Combination<br />

Controller<br />

Motor control<br />

MC<br />

(Magnetic <strong>Contactor</strong>)<br />

Motor overload<br />

protect<br />

100AF Rotary operation, Standard interruption<br />

Manual<br />

Self-Protected<br />

Adjustment<br />

range (A)<br />

Short circuit rating (kA)<br />

MC (Applied contactor)<br />

240V 480Y/277V 600Y/347V Metasol<br />

<strong>MMS</strong>-100S-17 11~17 100 50 10 MC-75a<br />

<strong>MMS</strong>-100S-22 14~22 100 50 10 MC-75a<br />

<strong>MMS</strong>-100S-26 18~26 100 50 10 MC-75a<br />

<strong>MMS</strong>-100S-32 22~32 100 50 10 MC-75a<br />

<strong>MMS</strong>-100S-40 28~40 100 50 10 MC-75a<br />

<strong>MMS</strong>-100S-50 34~50 100 50 10 MC-75a<br />

<strong>MMS</strong>-100S-63 45~63 100 40 10 MC-75a<br />

<strong>MMS</strong>-100S-75 55~75 100 40 10 MC-75a<br />

<strong>MMS</strong>-100S-90 70~90 100 40 10 MC-85a<br />

<strong>MMS</strong>-100S-100 80~100 100 40 10 MC-100a<br />

100AF Rotary operation, High interruption<br />

Manual<br />

Self-Protected<br />

Adjustment<br />

range (A)<br />

Short circuit rating (kA)<br />

MC (Applied contactor)<br />

240V 480Y/277V 600Y/347V Metasol<br />

<strong>MMS</strong>-100H-17 11~17 100 65 25 MC-75a<br />

<strong>MMS</strong>-100H-22 14~22 100 65 20 MC-75a<br />

<strong>MMS</strong>-100H-26 18~26 100 65 20 MC-75a<br />

<strong>MMS</strong>-100H-32 22~32 100 65 20 MC-75a<br />

<strong>MMS</strong>-100H-40 28~40 100 65 20 MC-75a<br />

<strong>MMS</strong>-100H-50 34~50 100 65 20 MC-75a<br />

<strong>MMS</strong>-100H-63 45~63 100 50 10 MC-75a<br />

<strong>MMS</strong>-100H-75 55~75 100 50 10 MC-75a<br />

<strong>MMS</strong>-100H-90 70~90 100 50 10 MC-85a<br />

<strong>MMS</strong>-100H-100 80~100 100 50 10 MC-100a<br />

136


Ready for IE3<br />

LS contactor ready for IE3-rated motors<br />

What is the IE3?<br />

Motor is rated from IE1 through IE4 depends on its energy efficiency which means IE3 is more efficient<br />

compared to IE1 and IE2-rated motors. IE3-rated motor is not only more efficient than IE2-rated motor<br />

but it also has lower rated current and higher starting current & inrush current.<br />

WHY IE3?<br />

As part of the EU Enviromental policy "20/30-20-20" strategy, the EU is committed to achieve the<br />

followings by 2020<br />

• Reduce greenhouse gas emissions by up to 30 %<br />

• Increase the share of renewable energy to 20 % and<br />

• Boost energy efficiency by 20% in general.IEC 60034-30 standard specifies IE classes for motors in<br />

accordance with the above requirements.<br />

• IEC 60034-30-1 standard<br />

- IE1 Standard Efficiency<br />

- IE2 High Efficiency<br />

- IE3 Premium Efficiency<br />

- IE4 Super Premium Efficiency<br />

IE3 motors can be associated with standard starter solutions, like contactor, manual motor starter.<br />

During the starting the IE3 motor, Inrush and starting current are increased compared with IE2 motor.<br />

The increased inrush and starting current can affect the selection of the electrical device.<br />

In order to secure the highest efficiency in your electrical system, it is strongly recommended to use the<br />

more efficient IE3 class product.<br />

<strong>LSIS</strong> contactors are already compliant with IE3.<br />

137


Ready for IE3<br />

Frame size 18AF 22AF 40AF 65AF<br />

Type MC-6a MC-9a MC-12a MC-18a MC-9b MC-12b MC-18b MC-22b MC-32a MC-40a MC-50a MC-65a<br />

AC-3 200/240V kW 1.1 1.5 2 2.5 1.5 2 2.5 3 4.5 5.5 7.5 9<br />

A 5 6 7.5 10 6 7.5 10 12.5 18 23 31.5 37<br />

380/440V kW 2 2.2 3.5 5 2.2 3.5 5 6.5 9 11 15 18.5<br />

A 4 5 7 10 5 7 10 12.5 18 23 28.5 37<br />

500/550V kW 2 2.2 4 4.5 2.2 4 4.5 7.5 10 11 15 22<br />

A 3.5 4 7 7.5 4 7 7.5 11.5 16 18 24.5 34<br />

690V kW 2 2.2 4 4 3 4 4 9 10 11 15 18.5<br />

A 2.3 3 5 5 3.5 5 5 10 11.5 13 16 20<br />

1000V kW - - - - - - - - 11 11 16 16<br />

A - - - - - - - - 9.7 9.7 13 13<br />

*Thermal <strong>Overload</strong> Relay” Products are available regardless of de-rating<br />

Frame size 100AF 150AF 225AF 400AF<br />

Type MC-75a MC-85a MC-100a MC-130a MC-150a MC-185a MC-225a MC-265a MC-330a MC-400a<br />

AC-3 200/240V kW 11 15 18.5 22 25 30 37 45 55 75<br />

A 43 49 60 74 86 106 126 151 189 229<br />

380/440V kW 22 25 30 40 45 55 75 85 110 132<br />

A 43 49 60 74 86 106 129 151 189 229<br />

500/550V kW 27 30 35 37 40 70 85 90 100 140<br />

A 37 43 49 51 57 103 114 129 143 200<br />

690V kW 22 25 30 30 30 65 80 100 130 160<br />

A 24 26 37 34 34 69 86 106 126 171<br />

1000V kW 20 20 20 37 37 70 70 80 80 80<br />

A 16 16 16 30 30 51 51 60 60 60<br />

*Thermal <strong>Overload</strong> Relay” Products are available regardless of de-rating<br />

Frame size 800AF 2100AF<br />

Type MC-500a MC-630a MC-800a MC-1400a MC-1700a MC-2100a<br />

AC-3 200/240V kW 80 110 132 147 180 -<br />

A 286 360 457 491 600 -<br />

380/440V kW 160 200 250 265 355 500<br />

A 286 360 457 491 600 829<br />

500/550V kW 160 200 280 - - -<br />

A 229 286 411 - - -<br />

690V kW 200 230 300 450 500 -<br />

A 217 240 360 491 543 -<br />

1000V kW 160 160 160 - - -<br />

A 126 126 126 - - -<br />

*Thermal <strong>Overload</strong> Relay” Products are available regardless of de-rating<br />

138


3-pole contactors dimension (18AF/22AF)<br />

MC-6a~18a AC<br />

1NO or 1NC<br />

[mm]<br />

0.3kg<br />

MC-6a~18a DC<br />

1NO or 1NC<br />

0.5kg<br />

MC-9b~22b AC<br />

1NO1NC<br />

* ( ) MC-18b, 22b<br />

0.3kg<br />

MC-9b~22b DC<br />

1NO1NC<br />

0.5kg<br />

139


3-pole contactors dimension (40AF)<br />

MC-32a~40a AC<br />

[mm]<br />

0.4kg<br />

MC-32a~40a DC<br />

0.6kg<br />

MC-32a~40a AC<br />

2NO2NC<br />

0.5kg<br />

MC-32a~40a DC<br />

2NO2NC<br />

0.8kg<br />

140


3-pole contactors dimension (65AF)<br />

MC-50a~65a AC<br />

[mm]<br />

0.9kg<br />

MC-50a~65a DC<br />

1.2kg<br />

MC-50a~65a AC<br />

2NO2NC<br />

1kg<br />

MC-50a~65a DC<br />

2NO2NC<br />

1.3kg<br />

141


3-pole contactors dimension (100AF)<br />

MC-75a~100a AC<br />

[mm]<br />

1.8kg<br />

MC-75a~100a DC<br />

2.7kg<br />

MC-75a~100a AC<br />

2NO2NC<br />

1.9kg<br />

MC-75a~100a DC<br />

2NO2NC<br />

2.8kg<br />

142


3-pole contactors dimension (150AF~400AF)<br />

MC-130a<br />

MC-150a<br />

[mm]<br />

2.4kg<br />

MC-185a<br />

MC-225a<br />

5.4kg<br />

MC-265a<br />

MC-330a<br />

MC-400a<br />

9.2kg<br />

* Optional auxiliary contact unit ( side mount type )<br />

143


3-pole contactors dimension (800AF~2100AF)<br />

[mm]<br />

MC-500a<br />

MC-630a<br />

285<br />

160<br />

M16 Bolt<br />

245.3<br />

149<br />

250<br />

4-M10<br />

(Mounting hole)<br />

MC-800a<br />

272<br />

290<br />

312<br />

250<br />

40<br />

22.4kg<br />

MC-1260a<br />

285<br />

160<br />

244.1<br />

148.8<br />

250<br />

4-M10<br />

(Mounting hole)<br />

431 245.6<br />

135 135<br />

M12 Bolt<br />

10<br />

138.8<br />

389<br />

136<br />

MC-1400a<br />

MC-1700a<br />

MC-2100a<br />

275<br />

343<br />

380<br />

290<br />

312<br />

250<br />

271<br />

290<br />

316<br />

352<br />

50<br />

27<br />

M12 Bolt<br />

4-M10<br />

4-M8<br />

144


Motor starters dimension (18AF~40AF)<br />

MS-6a~18a<br />

[mm]<br />

0.5kg<br />

MS-9b~22b<br />

0.5kg<br />

MS-32a~40a<br />

90<br />

66<br />

˝˝ ˝<br />

˝0˝ ˝<br />

˝6˝ ˝<br />

˝˝˝ 6<br />

0.6kg<br />

145


Motor starters dimension (65AF~150AF)<br />

MS-50a~65a<br />

M3.5<br />

(Coil terminal)<br />

M6<br />

(Main terminal)<br />

55<br />

119<br />

7<br />

M4<br />

(Mounting hole)<br />

4<br />

3<br />

47<br />

[mm]<br />

163.8<br />

M3.5<br />

(Aux terminal)<br />

M6<br />

(Main terminal)<br />

5.3<br />

131<br />

73<br />

1<br />

95<br />

3.7 11 . 8<br />

45.5<br />

1.3kg<br />

MS-75a~100a<br />

M3.5<br />

(Coil terminal)<br />

M8<br />

(Main terminal)<br />

7<br />

135.8<br />

6<br />

85<br />

M4<br />

(Mounting hole) . 5<br />

11. 4<br />

17 . 8<br />

1 5<br />

13<br />

M3.5<br />

(Aux terminal)<br />

M8<br />

(Main terminal)<br />

6<br />

11 . 7<br />

3.7 1 6. 5<br />

6 .<br />

2.3kg<br />

MS-130a<br />

MS-150a<br />

M3.5<br />

(Coil terminal)<br />

M8<br />

(Main terminal)<br />

95<br />

13 . 3<br />

7<br />

M5<br />

(Mounting hole)<br />

83<br />

7 . 7<br />

36.<br />

114<br />

184.1<br />

148<br />

146<br />

M3.5<br />

(Aux terminal)<br />

M8<br />

(Main terminal)<br />

3.7<br />

1 7. 4<br />

1 3. 3<br />

55.9<br />

2.9kg


Motor starters dimension (185AF~800AF)<br />

MS-185a<br />

MS-225a<br />

[mm]<br />

7.9kg<br />

MS-265a<br />

MS-330a<br />

MS-400a<br />

11.8kg<br />

MS-500a<br />

MS-630a<br />

MS-800a<br />

28kg<br />

147


Reversing contactors and starters dimension (18AF)<br />

MC-6aR~18aR AC<br />

[mm]<br />

0.7kg<br />

MC-6aR~18aR DC<br />

1kg<br />

MS-6aR~18aR AC<br />

0.9kg<br />

148


Reversing contactors and starters dimension (22AF)<br />

MC-9bR~22bR AC<br />

[mm]<br />

0.7kg<br />

MC-9bR~22bR DC<br />

1.1kg<br />

MS-9bR~22bR AC<br />

1.3kg<br />

149


Reversing contactors and starters dimension (40AF)<br />

MC-32aR~40aR AC<br />

102<br />

57<br />

90<br />

M4<br />

(Mounting hole)<br />

35<br />

35<br />

[mm]<br />

139.4<br />

51<br />

83<br />

51<br />

83<br />

60<br />

75<br />

0.9kg<br />

MC-32aR~40aR DC<br />

102<br />

57<br />

117.1<br />

M4<br />

(Mounting hole)<br />

35<br />

35<br />

51<br />

83<br />

60<br />

75<br />

1.4kg<br />

MS-32aR~40aR AC<br />

102<br />

57<br />

90<br />

45<br />

90<br />

1.1kg<br />

150


Reversing contactors and starters dimension (65AF)<br />

MC-50aR~65aR AC<br />

122<br />

67<br />

119<br />

47<br />

41<br />

47<br />

41<br />

[mm]<br />

119<br />

163.8<br />

71<br />

106<br />

71<br />

106<br />

146.4<br />

47<br />

41<br />

47<br />

41<br />

71<br />

106<br />

92<br />

100<br />

92<br />

100<br />

1.8kg<br />

MC-50aR~65aR DC<br />

122<br />

67<br />

2.4kg<br />

MS-50aR~65aR AC<br />

122<br />

67<br />

55<br />

100<br />

1.9kg<br />

151


Reversing contactors and starters dimension (100AF)<br />

MC-75aR~100aR AC<br />

152<br />

82<br />

135.8<br />

M4<br />

(Mounting hole)<br />

60<br />

55<br />

60<br />

55<br />

[mm]<br />

211.9<br />

103<br />

140<br />

130<br />

3.3kg<br />

MC-75aR~100aR DC<br />

152<br />

82<br />

172.3<br />

M4<br />

(Mounting hole)<br />

60<br />

55<br />

60<br />

55<br />

103<br />

140<br />

152<br />

82<br />

135.8<br />

103<br />

140<br />

130<br />

5.2kg<br />

MS-75aR~100aR AC<br />

70<br />

110<br />

3.8kg<br />

152


Reversing contactors and starters dimension (150~800AF)<br />

MC-130aR<br />

MC-150aR<br />

226<br />

202<br />

107<br />

130.3 83<br />

83<br />

M5<br />

72.7<br />

72.7<br />

(Mounting hole)<br />

[mm]<br />

335<br />

46 30<br />

195.1<br />

4-M8<br />

300<br />

128<br />

(Mounting hole)<br />

270<br />

164 53<br />

250<br />

21.5<br />

160 46.5<br />

381<br />

45<br />

50<br />

219.4<br />

147.5<br />

300<br />

330<br />

201<br />

300<br />

64.5<br />

25 185 55<br />

680<br />

4-M10<br />

320.1<br />

223.8<br />

440<br />

350<br />

320<br />

114<br />

158<br />

148<br />

4.3kg<br />

MC-185aR<br />

MC-225aR<br />

M4(Coil terminal)<br />

M4(Aux terminal)<br />

M10(Main terminal)<br />

12.9kg<br />

MC-265aR<br />

MC-330aR<br />

MC-400aR<br />

M4(Coil terminal)<br />

4-M8<br />

(Mounting hole)<br />

M4(Aux terminal)<br />

M12(Main terminal)<br />

21.4kg<br />

MC-500aR<br />

MC-630aR<br />

MC-800aR<br />

M4(Coil terminal)<br />

4-M10<br />

(Mounting hole)<br />

M16(Main terminal)<br />

60kg<br />

153


Reversing contactors and starters dimension (150~400AF)<br />

MS-130aR AC<br />

MS-150aR AC<br />

226<br />

202<br />

107<br />

130.3<br />

[mm]<br />

112.5<br />

25<br />

335<br />

46.5 160<br />

M4(Coil terminal) 30<br />

195.1<br />

300<br />

4-M8<br />

128<br />

(Mounting hole)<br />

317<br />

370<br />

350<br />

53<br />

25<br />

94<br />

76<br />

10<br />

30<br />

381<br />

55 185<br />

50 219.4<br />

147.5<br />

300<br />

415.5<br />

480<br />

450<br />

64.5<br />

236.2<br />

114<br />

158<br />

95<br />

5kg<br />

MS-185aR AC<br />

MS-225aR AC<br />

M10(Main terminal)<br />

15.5kg<br />

MS-265aR DC<br />

MS-330aR DC<br />

MS-400aR DC<br />

M4(Coil terminal)<br />

4-M8<br />

(Mounting hole)<br />

55<br />

60.5<br />

30<br />

M12(Main terminal)<br />

100<br />

10<br />

23kg<br />

154


45<br />

<strong>Contactor</strong> relays dimension<br />

80.4(96.6)<br />

M4<br />

(Mounting hole)<br />

36.5<br />

33.5<br />

45<br />

73.5<br />

80.4(96.6)<br />

M4<br />

(Mounting hole)<br />

65<br />

49.5<br />

36.5<br />

33.5<br />

MR-4 (D)<br />

45<br />

73.5<br />

80.4(96.6)<br />

M4<br />

(Mounting hole)<br />

65<br />

49.5<br />

36.5<br />

33.5<br />

[mm]<br />

73.5<br />

65<br />

49.5<br />

45<br />

111(141.3)<br />

M4<br />

(Mounting hole)<br />

36.5<br />

33.5<br />

284g<br />

MR-6 (D)<br />

45<br />

73.5<br />

111(141.3)<br />

M4<br />

(Mounting hole)<br />

65<br />

49.5<br />

36.5<br />

33.5<br />

45<br />

73.5<br />

111(141.3)<br />

M4<br />

(Mounting hole)<br />

65<br />

49.5<br />

36.5<br />

33.5<br />

73.5<br />

65<br />

49.5<br />

315g<br />

MR-8 (D)<br />

45<br />

111(127.2)<br />

M4<br />

(Mounting hole)<br />

36.5<br />

33.5<br />

45<br />

73.5<br />

111(127.2)<br />

M4<br />

(Mounting hole)<br />

65<br />

49.5<br />

36.5<br />

33.5<br />

45<br />

73.5<br />

111(127.2)<br />

M4<br />

(Mounting hole)<br />

65<br />

49.5<br />

36.5<br />

33.5<br />

339g<br />

Composition<br />

MR-4<br />

73.5<br />

65<br />

49.5<br />

Note1) Note1) Note1) Note1) Note1)<br />

MR-6<br />

Note2) Note2) Note2) Note2) Note2)<br />

MR-8<br />

Note) 1. UA-2: Auxiliary contact units 2. UA-4: Auxiliary contact units<br />

• Please refer to the contact diagram represented on catalog when contactor relays MR-4, 4D and auxiliary contact units UA-2,4 are purchased separately.<br />

• Be sure to order the auxiliary contact units separately except for the above contact units. • ( ) : Dimension for DC control contactor relays<br />

155


Latching contactors dimension (18AF/22AF)<br />

MC-6a~18a AC<br />

1NO or 1NC + ML-65<br />

45<br />

44.3<br />

30<br />

11.6<br />

135 36.5<br />

52.4<br />

M4<br />

33.5<br />

(Mounting hole)<br />

[mm]<br />

MC-6a~18a DC<br />

1NO or 1NC + ML-65<br />

MC-9b~22b AC<br />

1NO1NC + ML-65<br />

MC-9b~22b DC<br />

1NO1NC + ML-65<br />

45<br />

44.3<br />

10.9 10.9<br />

36.5<br />

33.5<br />

46<br />

44.2<br />

46.6<br />

73.5<br />

65<br />

49.5<br />

44.2<br />

46.6<br />

73.5<br />

65<br />

49.5<br />

45<br />

44.3<br />

30<br />

11.6<br />

151.9<br />

70<br />

M4<br />

(Mounting hole)<br />

36.5<br />

33.5<br />

44.2<br />

46.6<br />

73.5<br />

65<br />

49.5<br />

45<br />

44.3<br />

10.9 10.9<br />

142<br />

63.3<br />

M4<br />

(Mounting hole)<br />

36.5<br />

33.5<br />

44.2<br />

46.6<br />

73.5<br />

65<br />

49.5<br />

11.6<br />

159.3<br />

79<br />

M4<br />

(Mounting hole)<br />

11.6<br />

156


Latching contactors dimension (40AF)<br />

MC-32a~40a AC<br />

+ML-65<br />

45<br />

29<br />

22<br />

146<br />

66 M4<br />

35<br />

(Mounting hole)<br />

[mm]<br />

45<br />

29<br />

22<br />

173<br />

93.1 M4<br />

35<br />

(Mounting hole)<br />

69<br />

57<br />

45<br />

173<br />

35<br />

83<br />

60<br />

75<br />

51<br />

83<br />

60<br />

75<br />

51<br />

83<br />

60<br />

75<br />

0.5kg<br />

MC-32a~40a DC<br />

+ ML-65<br />

0.8kg<br />

MC-32a~40a AC<br />

2NO2NC + ML-65<br />

69<br />

57<br />

45<br />

146<br />

M4<br />

(Mounting hole)<br />

35<br />

83<br />

60<br />

75<br />

1kg<br />

MC-32a~40a DC<br />

2NO2NC + ML-65<br />

M4<br />

(Mounting hole)<br />

1.3kg<br />

157


Latching contactors dimension (65AF)<br />

MC-50a~65a AC<br />

55<br />

174<br />

47<br />

[mm]<br />

+ ML-65<br />

44.3<br />

72<br />

M4<br />

(Mounting hole)<br />

41<br />

55<br />

202<br />

47<br />

44.3<br />

99.4<br />

41<br />

79<br />

67<br />

55<br />

202 47<br />

44.3<br />

41<br />

44.2<br />

106<br />

92<br />

100<br />

44.2<br />

106<br />

92<br />

100<br />

44.2<br />

106<br />

92<br />

100<br />

1.9kg<br />

MC-50a~65a DC<br />

+ ML-65<br />

M4<br />

(Mounting hole)<br />

79<br />

2.8kg<br />

MC-50a~65a AC<br />

2NO2NC + ML-65<br />

67<br />

55<br />

44.3<br />

174 47<br />

41<br />

M4<br />

(Mounting hole)<br />

44.2<br />

106<br />

92<br />

100<br />

2.4kg<br />

MC-50a~65a DC<br />

2NO2NC + ML-65<br />

M4<br />

(Mounting hole)<br />

158<br />

2.4kg


Latching contactors dimension (100AF)<br />

MC-75a~100a AC<br />

+ ML-150<br />

70<br />

45<br />

26.4<br />

190<br />

85<br />

M4<br />

(Mounting hole)<br />

60<br />

55<br />

[mm]<br />

70<br />

45<br />

26.4<br />

226<br />

121.5<br />

60<br />

55<br />

94<br />

82<br />

70<br />

140<br />

103<br />

140<br />

130<br />

60<br />

55<br />

130<br />

60<br />

55<br />

130<br />

140<br />

103<br />

140<br />

130<br />

MC-75a~100a DC<br />

+ ML-150<br />

M4<br />

(Mounting hole)<br />

MC-75a~100a AC<br />

2NO2NC + ML-150<br />

94<br />

82<br />

70<br />

190<br />

M4<br />

(Mounting hole)<br />

MC-75a~100a DC<br />

2NO2NC + ML-150<br />

226<br />

M4<br />

(Mounting hole)<br />

159


Latching contactors dimension (150AF~400AF)<br />

MC-130a~150a<br />

2NO2NC + ML-150<br />

119<br />

95<br />

67<br />

44.3<br />

27.4<br />

184 83<br />

72<br />

72.7<br />

M4<br />

(Mounting hole)<br />

[mm]<br />

44.2<br />

114<br />

158<br />

148<br />

MC-185a<br />

188<br />

168<br />

4-M6<br />

(Mounting<br />

hole)<br />

MC-225a<br />

205<br />

MC-265a<br />

MC-330a<br />

MC-400a<br />

213 193<br />

7.4kg<br />

245<br />

267.7<br />

224<br />

250.1<br />

184<br />

4-M8<br />

(Mounting<br />

hole)<br />

11.6kg<br />

Composition<br />

MC-185a/L~400a/L<br />

Open<br />

Close<br />

160


4-pole contactors dimension (MC-6a/4~22a/4)<br />

MC-6a/4~18a/4 AC<br />

45<br />

M3.5(Coil terminal)<br />

M3.5(Main contact)<br />

10<br />

79<br />

M4(Mounting hole)<br />

36.5<br />

33.5<br />

[mm]<br />

46.6<br />

73.5<br />

10<br />

30.05<br />

45<br />

M3.5(Coil terminal)<br />

M3.5(Main contact)<br />

110.7<br />

M4(Mounting hole)<br />

36.5<br />

33.5<br />

46.6<br />

73.5<br />

10<br />

30.05<br />

M3.5(Coil terminal)<br />

M4(Main contact)<br />

46<br />

MC-22a/4 DC<br />

46<br />

65<br />

49.5<br />

65<br />

49.5<br />

0.3kg<br />

MC-6a/4~18a/4 DC<br />

10<br />

0.45kg<br />

86.8<br />

MC-22a/4 AC<br />

47.2<br />

10<br />

64.1<br />

2.5<br />

M4(Mounting hole)<br />

35<br />

30<br />

80<br />

50<br />

5<br />

11.3<br />

33.9<br />

5.4<br />

3<br />

0.4kg<br />

47.2<br />

M3.5(Coil terminal)<br />

M4(Main contact)<br />

10<br />

113.2<br />

90.5<br />

M4(Mounting hole)<br />

35<br />

2.5 30<br />

80<br />

50<br />

5<br />

11.3<br />

33.9<br />

5.4<br />

3<br />

0.5kg<br />

161


4-pole contactors dimension (MC-32a/4~85a/4)<br />

MC-32a/4~40a/4 AC<br />

94.6<br />

[mm]<br />

59<br />

M3.5(Coil terminal)<br />

10<br />

64.6<br />

M4(Mounting hole)<br />

M4(Main contact)<br />

42<br />

83.5<br />

51<br />

60<br />

42.6<br />

14.2<br />

0.59kg<br />

MC-32a/4~40a/4 DC<br />

59<br />

M3.5(Coil terminal)<br />

10<br />

121<br />

91<br />

M4(Mounting hole)<br />

M4(Main contact)<br />

42<br />

91<br />

M3.5(Coil terminal)<br />

M6(50a)<br />

M8(65a,75a,85a)<br />

10<br />

117.8<br />

82.4<br />

M4(Mounting hole)<br />

81<br />

5<br />

71<br />

123.5<br />

78<br />

100<br />

83.5<br />

51<br />

60<br />

42.6<br />

14.2<br />

0.7kg<br />

MC-50a/4~85a/4 AC<br />

22<br />

66<br />

1.2kg<br />

MC-50a/4~85a/4 DC<br />

91<br />

M3.5(Coil terminal)<br />

M6(50a)<br />

M8(65a,75a,85a)<br />

10<br />

117.8<br />

82.4<br />

M4(Mounting hole)<br />

81<br />

5<br />

71<br />

123.5<br />

78<br />

100<br />

162<br />

22<br />

66


4-pole contactors dimension (MC-100a/4~800a/4)<br />

MC-100a/4<br />

MC-130a/4<br />

MC-150a/4<br />

MC-185a/4<br />

MC-225a/4<br />

175<br />

139.5<br />

46.5<br />

M4(Coil terminal)<br />

M8(100a,130a,150a)<br />

30<br />

185.2<br />

118<br />

120<br />

45<br />

4-M6(Mounting hole)<br />

[mm]<br />

164<br />

203<br />

M4(Aux. contact)<br />

190<br />

M10(185a,225a)<br />

25<br />

5.6kg<br />

MC-265a/4<br />

MC-330a/4<br />

MC-400a/4<br />

206<br />

165<br />

55<br />

M4(Coil terminal)<br />

M4<br />

(Aux. contact)<br />

50<br />

205.2<br />

133.4<br />

145<br />

105<br />

4-M8(Mounting hole)<br />

201<br />

243<br />

M12<br />

(Main contact)<br />

225<br />

30<br />

MC-500a/4<br />

MC-630a/4<br />

MC-800a/4<br />

346<br />

240<br />

80<br />

M4(Coil terminal)<br />

50<br />

244.12<br />

147.9<br />

4-M10(Mounting hole)<br />

308<br />

9.9kg<br />

M4<br />

(Aux. contact)<br />

272<br />

310<br />

270<br />

M16<br />

(Main contact)<br />

40<br />

26.3kg<br />

163


Enclosed motor starters, Mold enclosure dimension<br />

MW-9bM~22bM<br />

[mm]<br />

108 90<br />

180<br />

149 15.5<br />

26.5<br />

48<br />

0.8kg<br />

MW-9bMB~22bMB<br />

108 90<br />

180<br />

15.5<br />

149<br />

26.5<br />

48<br />

0.8kg<br />

Circuit diagram<br />

MW-9bM~22bM<br />

MW-9bMB~22bMB<br />

A1<br />

A1<br />

A2<br />

A2<br />

R<br />

R S T 43 31<br />

S T 43 44 31 32<br />

96 95<br />

44<br />

32<br />

97 98<br />

96 95<br />

U V W<br />

97 98<br />

27<br />

28<br />

16<br />

15<br />

27<br />

28<br />

16<br />

I<br />

(ON)<br />

15<br />

O<br />

(OFF)<br />

I<br />

(ON)<br />

A1<br />

O<br />

(OFF)<br />

A1<br />

A2<br />

A2<br />

R S T 43<br />

R S T 43<br />

U<br />

V<br />

44<br />

W<br />

44<br />

31<br />

32<br />

96<br />

31<br />

32<br />

96<br />

97 98<br />

95<br />

97 98<br />

95<br />

U<br />

V<br />

W<br />

U<br />

V<br />

W<br />

ON<br />

OFF<br />

ON<br />

OFF<br />

164


Enclosed motor starters, Steel enclosure dimension<br />

MW-6a~100a<br />

[mm]<br />

MW-9b~22b<br />

Mounting hole<br />

AA<br />

BB<br />

A<br />

M(mounting hole)<br />

BA<br />

B<br />

CA<br />

C<br />

Earth hole<br />

AB<br />

Type A AA AB B BA BB C CA M N Weight(kg)<br />

MW-9b~22b, 6a~18a 104 76 40 170 140 15 114 41 M5 Ø22 1.1<br />

MW-32a, 40a 145 95 55 245 165 40 130 50 M5 Ø35 1.6<br />

MW-50a, 65a 160 120 74 290 220 35 141 50 M5 Ø35 2.7<br />

MW-75a, 85a, 100a 160 120 74 290 220 35 161 67 M5 Ø35 3.6<br />

Circuit diagram<br />

MW-6a~18a, MW-9b~22b<br />

MW-32a~100a<br />

A1<br />

A2<br />

13<br />

21<br />

R<br />

S<br />

A1 T<br />

43 A2 31 13<br />

21<br />

R<br />

S<br />

T<br />

43 31<br />

A1<br />

A2<br />

13<br />

21<br />

R<br />

S<br />

A1 T<br />

43 A2 31 13<br />

21<br />

R<br />

S<br />

T<br />

43 31<br />

14 22<br />

44 32 14 22<br />

Note1) 96<br />

95<br />

44 32<br />

Note2) 96<br />

95<br />

14<br />

22<br />

44 14 32 22<br />

96<br />

95<br />

44 32<br />

96<br />

95<br />

97 98<br />

97 98<br />

97 98<br />

97 98<br />

U<br />

V<br />

W<br />

U<br />

V<br />

W<br />

E<br />

E<br />

U<br />

V<br />

W<br />

U<br />

V<br />

W<br />

E<br />

ON<br />

OFF<br />

ON<br />

OFF<br />

ON<br />

OFF<br />

ON<br />

OFF<br />

Note) 1. In case of adding the auxiliary contact unit(1NO1NC).<br />

2. See below for MC-6a~18a(1NO)<br />

63<br />

64<br />

165


Enclosed motor starters, Steel enclosure dimension<br />

MW-6aB~100aB<br />

[mm]<br />

MW-9bB~22bB<br />

Mounting hole<br />

AA<br />

BB<br />

A<br />

BA<br />

B<br />

C<br />

M(mounting hole)<br />

CA<br />

Earth hole<br />

AB<br />

D<br />

Type A AA AB B BA BB C CA D M N Weight(kg)<br />

MW-9bB~22bB, 6aB~18aB 104 76 40 170 140 15 114 41 59 M5 Ø22 1.1<br />

MW-32aB, 40aB 145 95 55 245 165 40 130 50 97 M5 Ø35 1.6<br />

MW-50aB, 65aB 160 120 74 290 220 35 141 50 114 M5 Ø35 2.7<br />

MW-75aB, 85aB, 100aB 160 120 74 290 220 35 161 67 114 M5 Ø35 3.6<br />

Circuit diagram<br />

MW-6aB~18aB, MW-9bB~22bB<br />

MW-32aB~100aB<br />

A1 A2 13 21 RA1 A2 S 13 T21 R 43 S31<br />

T 43 31<br />

A1 A2 13 21 RA1 A2 S 13 T21<br />

R 43 S31<br />

T<br />

43<br />

31<br />

14<br />

22<br />

14<br />

22<br />

44<br />

32<br />

44<br />

32<br />

14<br />

22<br />

14<br />

22<br />

44<br />

32<br />

44<br />

32<br />

Note1)<br />

96<br />

95<br />

Note2)<br />

96<br />

95<br />

Note1)<br />

Note2)<br />

96<br />

95<br />

96<br />

95<br />

97<br />

98<br />

97<br />

98<br />

97<br />

98<br />

97<br />

98<br />

U<br />

V<br />

W<br />

U<br />

V<br />

W<br />

U<br />

V<br />

W<br />

U<br />

V<br />

W<br />

E<br />

E<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

3<br />

ON<br />

1<br />

1<br />

1<br />

3<br />

OFF<br />

ON<br />

1<br />

OFF<br />

3<br />

3<br />

1 1<br />

3 1 1 3<br />

OFF<br />

OFF<br />

ON<br />

ON<br />

Note) 1. In case of adding the auxiliary contact unit(1NO1NC).<br />

2. See below for MC-6a~18a(1NO)<br />

63<br />

64<br />

166


Capacitor contactors (MC-9b~40a with AC-9, MC 50a~100a with AC-50)<br />

MC-9b~22b<br />

with AC-9<br />

[mm]<br />

AC-9<br />

73.5<br />

140<br />

45<br />

120.4<br />

MC-32a,40a<br />

with AC-9<br />

AC-9<br />

83<br />

140<br />

45<br />

124.4<br />

MC-50a,65a<br />

with AC-50<br />

106<br />

170<br />

55<br />

153.2<br />

MC-75a~100a<br />

with AC-50<br />

AC-50<br />

140<br />

170<br />

70<br />

168.7<br />

Circuit diagram<br />

MC-9b~22b with AC-9<br />

MC-32a, 40a with AC-9 MC 50a~100a with AC-50<br />

167


2-pole AC <strong>Contactor</strong>s dimension (GMC-10P2~40P2)<br />

GMC-10P2<br />

GMC-20P2<br />

GMC-25P2<br />

Mounting hole<br />

[mm]<br />

GMC-30P2<br />

GMC-35P2<br />

Coil terminal<br />

GMC-40P2<br />

(TSBS Type)<br />

1.29kg<br />

Mounting hole<br />

GMC-10P2<br />

Coil terminal<br />

GMC-20P2<br />

GMC-25P2<br />

Mounting hole<br />

GMC-30P2<br />

GMC-35P2<br />

Coil terminal<br />

GMC-40P2<br />

87.6<br />

(TQBS Type)<br />

1.29kg<br />

Composition<br />

GMC - 10P2~40P2<br />

Mounting hole<br />

Coil terminal<br />

87.6<br />

Terminal<br />

Wire Torque A×B×C<br />

Type Terminals Screw<br />

(mm²) (kgf·cm) (mm)<br />

GMC-10P2~40P2<br />

Main M5 1-16 26 12.2×7×8<br />

Coil terminal<br />

Coil M3.5 1-2.5 12 7.7×7.5×4.5<br />

87.6<br />

C<br />

B<br />

A<br />

Mounting hole<br />

168


52.5<br />

65<br />

3-pole AC <strong>Contactor</strong>s dimension (GMC-20D, 25D)<br />

52.5<br />

GMC-20D<br />

GMC-25D<br />

65<br />

52.5<br />

42<br />

14<br />

M3.5 (Coil terminal)<br />

M4(Main terminal)<br />

10<br />

65<br />

52.5<br />

A1 A2 L1<br />

34<br />

30<br />

L1<br />

[mm]<br />

42<br />

14<br />

65<br />

52.5 M3.5 (Coil terminal)<br />

M4(Main terminal)<br />

Contact arrangement<br />

10<br />

65<br />

52.5<br />

13.4<br />

2NO<br />

46.5<br />

37.9<br />

42<br />

14<br />

78.6<br />

34<br />

30<br />

M3.5 (Coil terminal)<br />

M4(Main terminal)<br />

10<br />

A1 A2 L1<br />

46.5<br />

37.9<br />

78.6<br />

T1<br />

3NO<br />

L1<br />

T2<br />

65<br />

52.5<br />

48 7.5<br />

T1<br />

T2<br />

A1 A2 L1 L2 L3<br />

7.5<br />

7.5<br />

48<br />

T1 T2 T3<br />

2NO1NC<br />

7.5<br />

34<br />

30<br />

46.5<br />

37.9<br />

78.6<br />

A1 A2 L1<br />

7.5<br />

48<br />

13.4<br />

L1<br />

A1 A2 L1 L2 L3<br />

A1 A2 L1 ( b ) L2<br />

3.4<br />

65<br />

52.5<br />

34<br />

30<br />

T1<br />

7.5<br />

T2<br />

T1 T2 T3<br />

B C<br />

T1 ( b )<br />

T2<br />

Terminal<br />

7.5<br />

Type<br />

48<br />

Screw<br />

Wire A1 A2 L1 Torque L2 L3<br />

A×B×C<br />

(mm²) (kgf·cm) (mm)<br />

A1 A2 L1 ( b ) L2<br />

A<br />

B C<br />

GMC-20D~25D M4 1-10 15 9.4×5×85.1<br />

34<br />

30<br />

Coil~ M3.5 1.25~2 12 8×5×4.9<br />

T1 T2 T3<br />

7.5<br />

B C<br />

T1 ( b )<br />

T2<br />

A<br />

A1 A2 L1 ( b ) L2<br />

Single-pole AC <strong>Contactor</strong>s (MC-65aSP)<br />

A<br />

T1 ( b )<br />

T2<br />

MC-65aSP<br />

B C<br />

Composition<br />

A<br />

79<br />

55<br />

41<br />

47<br />

41<br />

without<br />

auxiliary<br />

contact<br />

71<br />

106<br />

81<br />

104<br />

92<br />

100<br />

with<br />

auxiliary<br />

contacts<br />

0.65kg<br />

169


DC <strong>Contactor</strong>s dimension (MD-30a, 60a,100a)<br />

MD-30a AC(DC)<br />

2NO2NC<br />

79<br />

55<br />

36<br />

21.8<br />

119(146.4) 47<br />

72(99.4)<br />

41<br />

[mm]<br />

73<br />

106<br />

92<br />

100<br />

MD-60a,100a AC(DC)<br />

2NO2NC<br />

94<br />

70<br />

45<br />

26.4<br />

135.8(172.3)<br />

85(121.5)<br />

60<br />

55<br />

105<br />

140<br />

130<br />

Composition<br />

MD-30a, 60a, 100a<br />

A1<br />

A2<br />

13 21 1<br />

5<br />

43 31<br />

14 22 44 32<br />

2<br />

6<br />

Contact arrangement<br />

Current<br />

5<br />

6<br />

M<br />

1 2<br />

A1<br />

A2<br />

170


<strong>Overload</strong> relays dimension<br />

MT-12<br />

45 63.7<br />

43.1<br />

[mm]<br />

3.7 96.3<br />

57.5<br />

80.6<br />

17.5<br />

M3.5<br />

(Aux terminal)<br />

95-NC-96 97-NO-98<br />

2T1 4T2 6T3<br />

M6<br />

(Main terminal)<br />

14<br />

55<br />

18<br />

5.3<br />

Main terminal<br />

80.5<br />

31<br />

3.7 106.3<br />

64.8<br />

97.2<br />

17.5<br />

60.1<br />

73.2<br />

100g<br />

MT-32<br />

45<br />

74.55<br />

167g<br />

MT-63<br />

Aux terminal<br />

303g<br />

MT-95<br />

95-NC-96<br />

97-NO-98<br />

M3.5<br />

(Aux terminal)<br />

Aux terminal<br />

M8<br />

(Main terminal)<br />

2T1 4T2 6T3<br />

17<br />

22.5<br />

70<br />

6<br />

Main terminal<br />

90.5<br />

42<br />

474g<br />

171


<strong>Overload</strong> relays dimension<br />

MT-150<br />

67 61<br />

[mm]<br />

M8(Main screw)<br />

113<br />

47<br />

47<br />

113.5<br />

M10(Main screw)<br />

184<br />

65.5<br />

110<br />

127<br />

M12(Main screw)<br />

121<br />

151<br />

198<br />

85<br />

360<br />

320<br />

250<br />

200<br />

160<br />

500<br />

530<br />

143<br />

171<br />

141<br />

109<br />

95<br />

0.7kg<br />

MT-225<br />

147<br />

2.5kg<br />

MT-400<br />

2.6kg<br />

MT-800<br />

40<br />

172<br />

M16(Main screw)<br />

160<br />

11.5kg


<strong>Overload</strong> relays dimension (Separate mount)<br />

UZ-12<br />

42.8<br />

64 4.7<br />

Main terminal<br />

45<br />

8.9 10 35<br />

M4(Mounting hole)<br />

[mm]<br />

45<br />

11.8 14.3<br />

M4(Mounting hole)<br />

35<br />

25.5<br />

M4/M5(34A)<br />

(Main terminal)<br />

45<br />

11.8 14.3<br />

93<br />

M4(Mounting hole)<br />

35<br />

85<br />

Main terminal<br />

25.5<br />

Aux terminal<br />

M4/M5(34A)<br />

(Main terminal)<br />

93<br />

85<br />

Aux terminal<br />

Main<br />

terminal<br />

Main terminal<br />

55<br />

14 18<br />

M4(Mounting hole)<br />

40<br />

Main terminal<br />

M6<br />

(Main terminal)<br />

55<br />

14 18<br />

42.2<br />

5<br />

107.5<br />

M4(Mounting hole)<br />

5<br />

40<br />

94.5<br />

M6<br />

(Main terminal)<br />

42.2<br />

107.5<br />

94.5<br />

Main<br />

terminal<br />

Aux terminal<br />

70<br />

17 22.5<br />

M4(Mounting hole)<br />

60<br />

Main terminal<br />

M8<br />

(Main terminal)<br />

70<br />

17 22.5<br />

M4(Mounting hole)<br />

60<br />

120<br />

110<br />

88<br />

81<br />

25.5<br />

Aux terminal<br />

20.4<br />

44.5<br />

Main terminal<br />

35g<br />

UZ-32<br />

Main terminal<br />

Main<br />

terminal<br />

68g<br />

UZ-63<br />

Aux terminal<br />

Main<br />

terminal<br />

Main terminal<br />

44.6<br />

134g<br />

M8<br />

(Main terminal)<br />

44.6<br />

Aux terminal<br />

120<br />

110<br />

Main<br />

terminal<br />

Aux terminal<br />

173<br />

Main<br />

24.1<br />

95<br />

33.5<br />

M4(Mounting hole)


Main terminal<br />

Main terminal<br />

M6<br />

(Main terminal)<br />

55<br />

14 18<br />

42.2<br />

5<br />

M4(Mounting hole)<br />

5<br />

40<br />

M6<br />

(Main terminal)<br />

<strong>Overload</strong> relays dimension (Separate mount)<br />

Aux terminal<br />

42.2<br />

107.5<br />

107.5<br />

94.5<br />

94.5<br />

Main<br />

terminal<br />

Aux terminal<br />

Main<br />

terminal<br />

70<br />

[mm]<br />

UZ-95<br />

Main terminal<br />

17 22.5<br />

70<br />

M4(Mounting hole)<br />

60<br />

Main terminal<br />

M8<br />

(Main terminal)<br />

17 22.5<br />

44.6<br />

M4(Mounting hole)<br />

60<br />

M8<br />

(Main terminal)<br />

44.6<br />

120<br />

110<br />

Aux terminal<br />

120<br />

110<br />

Main<br />

terminal<br />

Aux terminal<br />

230g<br />

Main<br />

terminal<br />

24.1<br />

95<br />

33.5<br />

M4(Mounting hole)<br />

24.1<br />

95<br />

33.5<br />

M4(Mounting hole)<br />

UZ-150<br />

M8<br />

(Main Screw)<br />

M8<br />

(Main Screw)<br />

140<br />

Aux terminal<br />

140<br />

Aux terminal<br />

Main terminal<br />

Main terminal<br />

284g<br />

174


Delayed Opening Device<br />

Dimension<br />

AD - 9<br />

99<br />

35<br />

95<br />

35 36 37 38 39 40<br />

AC Power<br />

A2<br />

MC<br />

A1<br />

SW<br />

118<br />

100<br />

35 36 37 38 39 40<br />

Rs<br />

r<br />

- +<br />

R<br />

Delayed open device<br />

1.6<br />

87<br />

AD - 50<br />

AD - 100<br />

AD - 300<br />

AD - 600<br />

3-M4<br />

Mounting hole<br />

Electronic<br />

circuit<br />

Delayed<br />

open<br />

device<br />

AC Power<br />

Magnetic<br />

<strong>Contactor</strong><br />

Control<br />

Terminal<br />

M3.5<br />

0.5kg<br />

Control Circuit Diagram<br />

AD - 9 AD - 50~600<br />

Delayed open device<br />

Delayed open device<br />

SI, RF : Rectifier<br />

C : Condenser<br />

Rs : Resistance in series<br />

Electronic<br />

circuit<br />

SI, RF : Rectifier<br />

C : Condenser<br />

Rs : Resistance in series<br />

175


Electronic timer unit<br />

Electronic timer unit<br />

ON delay timer<br />

On time(Close MC) delay of magnetic contactors 1~30sec<br />

Circuit diagram<br />

18 16 15 A1 A2<br />

OFF delay timer<br />

Off time(Open MC) delay of magnetic contactors 1~30sec<br />

Circuit diagram<br />

18 15 S1 S2 A1 A2<br />

18 15 S1 S2 A1 A2<br />

18 15 S1 S2 A1 A2<br />

18 15 S1 S2 A1 A2<br />

Dimension<br />

40.2<br />

40.2<br />

40.2<br />

43<br />

43<br />

43<br />

30<br />

30<br />

30<br />

4.5<br />

4.5<br />

4.5<br />

176


177<br />

A2<br />

A1<br />

V<br />

U<br />

R<br />

S<br />

64<br />

W<br />

T 63<br />

MC-6a~18a<br />

1NO<br />

A2<br />

A1<br />

V<br />

U<br />

R<br />

S<br />

W<br />

T<br />

52<br />

51<br />

A2<br />

A1<br />

V<br />

U<br />

R<br />

S<br />

44<br />

W<br />

T 43<br />

32<br />

31<br />

MC-9b~22b<br />

A2<br />

A1<br />

V<br />

U<br />

R<br />

S<br />

14 W<br />

T<br />

13<br />

22<br />

21<br />

44<br />

43<br />

32<br />

31<br />

MC-32a~150a<br />

A2<br />

A1<br />

V<br />

U<br />

R<br />

S<br />

W<br />

T<br />

1NC<br />

2NO2NC<br />

1NO1NC<br />

<strong>Contactor</strong>s<br />

Contact arrangement


Contact arrangement<br />

Motor starters<br />

MS-6a~150a<br />

R/1/L1 S/3/L2 T/5/L3<br />

A1<br />

A2<br />

A1<br />

A2<br />

97 95<br />

2/T1 4/T2 6/T3<br />

98 96<br />

13 21<br />

R/1/L1 S/3/L2 T/5/L3<br />

43 31<br />

A1<br />

A2<br />

A1<br />

A2<br />

14 22<br />

44 32<br />

97 95<br />

2/T1 4/T2 6/T3<br />

98 96<br />

MS-185a~800a<br />

A2<br />

A1<br />

13<br />

21 R/1/L1 S/3/L2 T/5/L3<br />

43<br />

31<br />

14<br />

22<br />

44 32<br />

97<br />

95<br />

CT<br />

CT<br />

2/T1 4/T2 6/T3<br />

98<br />

96<br />

178


Reversing contactors<br />

MC-6aR~150aR<br />

A1<br />

A2<br />

R/1/L1 S/3/L2 T/5/L3<br />

111NC R/1/L1 S/3/L2<br />

121NC<br />

T/5/L3<br />

A1<br />

A2<br />

A1<br />

A2<br />

U/2/T1<br />

V/4/T2 W/6/T3<br />

112NC<br />

122NC<br />

U/2/T1 V/4/T2 W/6/T3<br />

A1<br />

A2<br />

MC-185aR~800aR<br />

R/1/L1<br />

S/3/L2<br />

T/5/L3<br />

R/1/L1<br />

S/3/L2<br />

T/5/L3<br />

23 41 13<br />

31<br />

A1<br />

A2<br />

23 4113<br />

31 A1<br />

A2<br />

24 42 14 32<br />

U/2/T1<br />

V/4/T2<br />

W/6/T3<br />

U/2/T1<br />

V/4/T2<br />

W/6/T3<br />

24 42 14<br />

32<br />

MS-6aR~150aR<br />

A1<br />

A2<br />

R/1/L1 S/3/L2 T/5/L3<br />

111NC<br />

121NC<br />

R/1/L1 S/3/L2 T/5/L3<br />

A1<br />

A2<br />

A1<br />

A2<br />

U/2/T1<br />

V/4/T2<br />

W/6/T3<br />

112NC<br />

122NC<br />

U/2/T1<br />

V/4/T2<br />

W/6/T3<br />

A1<br />

A2<br />

97 95<br />

2/T1 4/T2 6/T3<br />

98 96<br />

MS-185aR~400aR<br />

13 31 R/1/L1 S/3/L2 T/5/L3 23 41 A1 A2<br />

13<br />

T/5/L3<br />

31 R/1/L1 S/3/L2 23 41 A1 A2<br />

U/2/T1<br />

V/4/T2<br />

W/6/T3<br />

U/2/T1<br />

V/4/T2<br />

W/6/T3<br />

14 32<br />

24<br />

42<br />

14<br />

32<br />

24<br />

42<br />

97 95<br />

2/T1 4/T2 6/T3 98 96<br />

179


Meta-MEC and Metasol MC comparison table<br />

Manufactured products<br />

Type<br />

Metasol<br />

MC<br />

Current<br />

and<br />

200~240V<br />

power 380~440V<br />

AC3<br />

500~550V<br />

Auxiliary (Standard)<br />

Mounting size<br />

MC-6a MC-9a MC-12a MC-18a<br />

2.2kW 2.5kW 3.5kW 4.5kW<br />

9A 11A 13A 18A<br />

3kW 4kW 5.5kW 7.5kW<br />

7A 9A 12A 18A<br />

3kW 4kW 7.5kW 7.5kW<br />

6A 7A 12A 13A<br />

1NO or 1NC<br />

49.5~65<br />

33.5~36.5<br />

Mounting<br />

hole<br />

49.5~65<br />

MC-9b MC-12b MC-18b MC-22b<br />

2.5kW 3.5kW 4.5kW 5.5kW<br />

11A 13A 18A 22A<br />

4kW 5.5kW 7.5kW 11kW<br />

9A 12A 18A 22A<br />

4kW 7.5kW 7.5kW 15kW<br />

7A 12A 13A 20A<br />

1NO1NC<br />

33.5~36.5<br />

49.5~65<br />

60~75<br />

33.5~36.5 35<br />

Mounting 33.5~36.5 Mounting Mounting<br />

hole<br />

Mounting hole hole<br />

hole<br />

49.5~65<br />

60~75<br />

92~100<br />

MC-32a MC-40a<br />

7.5kW 11kW<br />

32A 40A<br />

15kW 18.5kW<br />

32A 40A<br />

18.5kW 22kW<br />

28A 32A<br />

-<br />

35 41~47 35 35<br />

Mounting Mounting<br />

hole hole<br />

60~75<br />

60~75<br />

Mounting<br />

hole<br />

MC-50a<br />

15kW<br />

55A<br />

22kW<br />

50A<br />

30kW<br />

43A<br />

Mounting<br />

hole<br />

92~100<br />

41~47<br />

MC-65a<br />

18.5kW<br />

65A<br />

30kW<br />

65A<br />

33kW<br />

60A<br />

-<br />

92~100<br />

41~47<br />

Mounting<br />

hole<br />

92~100<br />

41~47<br />

Mounting Mounting<br />

hole hole<br />

Discontinued priducts<br />

Weight (kg)<br />

Demension (W×H×D)<br />

Type<br />

Meta-MEC Current 200~220V<br />

MC and<br />

power 380~440V<br />

AC3<br />

500~550V<br />

Auxiliary (Standard)<br />

Mounting size<br />

0.33<br />

45×73.5×80.4<br />

-<br />

-<br />

-<br />

-<br />

-<br />

-<br />

0.34<br />

0.4<br />

0.9<br />

45×73.5×87.4<br />

45×83×90 55×106×119<br />

GMC-9 GMC-12 GMC-18 GMC-22 GMC-32 GMC-40 GMC-50 GMC-65<br />

2.5kW 3.5kW 4.5kW 5.5kW 7.5kW 11kW 15kW 18.5kW<br />

11A 13A 18A 22A 32A 40A 55A 65A<br />

4kW 5.5kW 7.5kW 11kW 15kW 18.5kW 22kW 30kW<br />

9A 12A 18A 22A 32A 40A 50A 65A<br />

4kW 7.5kW 7.5kW 15kW 18.5kW 22kW 30kW 33kW<br />

7A 12A 13A 22A 28A 32A 43A 60A<br />

1NO1NC 1NO1NC 1NO1NC 1NO1NC 2NO2NC 2NO2NC 2NO2NC 2NO2NC<br />

Mounting Mounting Mounting<br />

hole hole hole Mounting Mounting Mounting<br />

hole<br />

hole hole<br />

Mounting<br />

hole<br />

MountingMountin<br />

hole hole<br />

Weight (kg)<br />

Demension (W×H×D)<br />

Compatibility with Metasol<br />

-<br />

-<br />

-<br />

0.33 0.37 0.45 1<br />

44×80×86.8 68×82×94.6 94×122×115.7<br />

◦ ▲ ▲<br />

Note) Marks of compatibility<br />

: can be compatible<br />

▲: compatible when applied the bracket<br />

×: can't be compatible(have to use bracket)<br />

180


MC-75a MC-85a MC-100a<br />

22 kW 25kW 30kW<br />

75A 85A 105A<br />

37 kW 45kW 55kW<br />

75A 85A 105A<br />

37 kW 45 kW 55kW<br />

64A 75A 85A<br />

-<br />

MC-130a<br />

37kW<br />

130A<br />

60kW<br />

130A<br />

60kW<br />

90A<br />

MC-150a<br />

45kW<br />

150A<br />

75kW<br />

150A<br />

70kW<br />

100A<br />

-<br />

MC-185a MC-225a<br />

55kW 75kW<br />

185A 225A<br />

90kW 132kW<br />

185A 225A<br />

110kW 132kW<br />

180A 200A<br />

2NO2NC<br />

MC-265a MC-330a MC-400a<br />

80kW 90kW 125kW<br />

265A 330A 400A<br />

147kW 160kW 200kW<br />

265A 330A 400A<br />

147kW 160kW 225kW<br />

225A 280A 350A<br />

2NO2NC<br />

MC-500a MC-630a MC-800a<br />

147kW 190kW 220kW<br />

500A 630A 800A<br />

265kW 330kW 440kW<br />

500A 630A 800A<br />

265kW 330kW 500kW<br />

400A 500A 720A<br />

2NO2NC<br />

55~60<br />

Mounting Mounting Mounting Mounting<br />

Mounting<br />

hole<br />

hole hole hole<br />

hole<br />

Mounting55~60<br />

Mounting<br />

55~60<br />

Mounting Mounting 55~60<br />

Mounting Mounting Mounting Mounting Mounting Mounting Mounting Mounting Mounting Mounting Mounting Mounting Mounting Mounting Mounting<br />

hole<br />

hole hole hole<br />

hole hole hole hole hole hole hole hole hole hole hole<br />

hole hole hole hole<br />

Mounting<br />

hole<br />

130<br />

130<br />

130<br />

148 130<br />

148<br />

130<br />

148<br />

148<br />

148<br />

1.6<br />

2.4<br />

5.4<br />

9.2<br />

22.4<br />

70×140×135.8<br />

95×158×130.3 138×203×185.1<br />

163×243×204.4<br />

285×312×245.3<br />

GMC-75 GMC-85 GMC-100 GMC-125 GMC-150 GMC-180 GMC-220 - GMC-300 GMC-400 - GMC-600 GMC-800<br />

22kW 25kW 30kW 37kW 45kW 55kW 75kW 90kW 125kW 190kW 220kW<br />

-<br />

-<br />

75A 85A 105A 125A 150A 180A 250A 300A 400A 630A 800A<br />

37kW 45kW 55kW 60kW 75kW 90kW 132kW 160kW 200kW 330kW 440kW<br />

-<br />

-<br />

75A 85A 105A 120A 150A 180A 250A 300A 400A 630A 800A<br />

37kW 45kW 55kW 60kW 90kW 110kW 132kW 160kW 225kW 330kW 500kW<br />

-<br />

-<br />

64A 75A 85A 90A 140A 180A 200A 250A 350A 500A 720A<br />

2NO2NC 2NO2NC 2NO2b 2NO2NC 2NO2NC 2NO2NC 2NO2NC - 2NO2NC 2NO2NC - 2NO2NC 2NO2NC<br />

ounting<br />

ole<br />

Mounting<br />

hole<br />

Mounting<br />

Mounting<br />

hole<br />

hole<br />

Mounting<br />

Mounting<br />

Mounting<br />

hole hole hole<br />

hole<br />

Mounting<br />

hole<br />

Mounting<br />

Mounting<br />

hole<br />

hole<br />

Mounting<br />

Mounting<br />

Mounting<br />

hole<br />

hole<br />

hole<br />

Mounting<br />

Mounting<br />

Mounting<br />

hole<br />

hole hole hole<br />

Mounting<br />

hole<br />

1 2.9 3.4 5.4 -<br />

9.2 -<br />

22<br />

94×122×115.7 100×157.4×146.5 120×166×157 138×203×181 -<br />

163×243×198 - 285×290×242<br />

▲ × × ◦ -<br />

◦ -<br />

◦<br />

181


Meta-MEC and Metasol MS comparison table<br />

Manufactured products<br />

Metasol<br />

MC<br />

Type<br />

Current 200~240V<br />

and<br />

power 380~440V<br />

AC3<br />

500~550V<br />

Auxiliary (Standard)<br />

Mounting size<br />

MS-6a MS-9a MS-12a MS-18a<br />

2.2kW 2.5kW 3.5kW 4.5kW<br />

9A 11A 13A 18A<br />

3kW 4kW 5.5kW 7.5kW<br />

7A 9A 12A 18A<br />

3kW 4kW 7.5kW 7.5kW<br />

6A 7A 12A 13A<br />

1NO or 1NC<br />

49.5~65<br />

33.5~36.5<br />

Mounting<br />

hole<br />

49.5~65<br />

MS-9b MS-12b MS-18b MS-22b<br />

2.5kW 3.5kW 4.5kW 5.5kW<br />

11A 13A 18A 22A<br />

4kW 5.5kW 7.5kW 11kW<br />

9A 12A 18A 22A<br />

4kW 7.5kW 7.5kW 15kW<br />

7A 12A 13A 20A<br />

1NO1NC<br />

33.5~36.5<br />

49.5~65 60~75<br />

33.5~36.5 Mounting<br />

35 33.5~36.5MountingMounting<br />

hole hole Mounting hole<br />

hole<br />

49.5~65<br />

60~75<br />

92~100<br />

35<br />

MS-32a MS-40a<br />

7.5kW 11kW<br />

32A 40A<br />

15kW 18.5kW<br />

32A 40A<br />

18.5kW 22kW<br />

28A 32A<br />

-<br />

41~47 35 35<br />

Mounting Mounting Mounting<br />

hole hole hole<br />

60~75<br />

60~75<br />

MS-50a<br />

15kW<br />

55A<br />

22kW<br />

50A<br />

30kW<br />

43A<br />

Mounting<br />

hole<br />

92~100<br />

41~47<br />

MS-65a<br />

18.5kW<br />

65A<br />

30kW<br />

65A<br />

33kW<br />

60A<br />

-<br />

92~100<br />

41~47<br />

Mounting<br />

hole<br />

92~100<br />

41~47<br />

Mounting<br />

hole<br />

Mountin<br />

hole<br />

Discontinued priducts<br />

Meta-<br />

MEC<br />

MC<br />

Weight (kg)<br />

Demension (W×H×D)<br />

Type<br />

Current 200~220V<br />

and<br />

power 380~440V<br />

AC3<br />

500~550V<br />

Auxiliary (Standard)<br />

Mounting size<br />

0.5<br />

45×124×80.4<br />

-<br />

-<br />

-<br />

-<br />

-<br />

-<br />

0.5<br />

45×129.9×87.4<br />

0.7<br />

45×139.4×90<br />

GMS-9 GMS-12 GMS-18 GMS-22 GMS-32 GMS-40 GMS-50 GMS-65<br />

2.5kW 3.5kW 4.5kW 5.5kW 7.5kW 11kW 15kW 18.5kW<br />

11A 13A 18A 22A 32A 40A 55A 65A<br />

4kW 5.5kW 7.5kW 11kW 15kW 18.5kW 22kW 30kW<br />

9A 12A 18A 22A 32A 40A 50A 65A<br />

4kW 7.5kW 7.5kW 15kW 18.5kW 22kW 30kW 33kW<br />

7A 12A 13A 22A 28A 32A 43A 60A<br />

1NO1NC 1NO1NC 1NO1NC 1NO1NC 2NO2NC 2NO2NC 2NO2NC 2NO2NC<br />

Mounting Mounting Mounting<br />

hole hole hole Mounting Mounting Mounting<br />

hole<br />

hole hole<br />

1.5<br />

55×163.8×119<br />

Mounting<br />

hole<br />

Mounting<br />

hole<br />

Mountin<br />

hole<br />

Weight (kg)<br />

Demension (W×H×D)<br />

Compatibility with Metasol<br />

Note) Marks of compatibility<br />

: can be compatible<br />

×: can't be compatible(have to use bracket)<br />

-<br />

-<br />

-<br />

0.46 0.5 0.45 1.12<br />

44×128.9×86.8 68×136.5×94.6 94×181.5×115.7<br />

◦ × ×<br />

182


MS-75a MS-85a MS-100a<br />

22 kW 25kW 30kW<br />

75A 85A 105A<br />

37 kW 45kW 55kW<br />

75A 85A 105A<br />

37 kW 45 kW 55kW<br />

64A 75A 85A<br />

-<br />

MS-130a<br />

37kW<br />

130A<br />

60kW<br />

130A<br />

60kW<br />

90A<br />

MS-150a<br />

45kW<br />

150A<br />

75kW<br />

150A<br />

70kW<br />

100A<br />

-<br />

MS-185a MS-225a<br />

55kW 75kW<br />

185A 225A<br />

90kW 132kW<br />

185A 225A<br />

110kW 132kW<br />

180A 200A<br />

2NO2NC<br />

MS-265a MS-330a MS-400a<br />

80kW 90kW 125kW<br />

265A 330A 400A<br />

147kW 160kW 200kW<br />

265A 330A 400A<br />

147kW 160kW 225kW<br />

225A 280A 350A<br />

2NO2NC<br />

MS-500a MS-630a MS-800a<br />

147kW 190kW 220kW<br />

500A 630A 800A<br />

265kW 330kW 440kW<br />

500A 630A 800A<br />

265kW 330kW 500kW<br />

400A 500A 720A<br />

2NO2NC<br />

55~60<br />

Mounting<br />

hole<br />

Mounting 55~60 55~60 Mounting<br />

55~60<br />

Mounting<br />

hole<br />

hole hole<br />

Mounting Mounting Mounting<br />

hole hole<br />

hole<br />

Mounting 55~60<br />

Mounting<br />

hole<br />

hole hole<br />

Mounting<br />

hole<br />

Mounting Mounting<br />

Mounting<br />

hole hole hole<br />

Mounting Mounting Mounting<br />

Mounting<br />

hole hole hole hole hole<br />

Mounting Mounting Mounting Mounting<br />

hole hole hole<br />

hole<br />

Mounting<br />

hole<br />

130<br />

130<br />

130<br />

148<br />

130<br />

148<br />

148<br />

130<br />

148<br />

148<br />

2.4<br />

3<br />

7.9<br />

11.8<br />

28<br />

70×211.4×135.8<br />

95×236.2×130.3 138×306.5×185.1<br />

163×380×204.4<br />

360×530×245.3<br />

GMC-75 GMC-85 GMC-100 GMC-125 GMC-150 GMC-180 GMC-220 - GMC-300 GMC-400 - GMC-600 GMC-800<br />

22kW 25kW 30kW 37kW 45kW 55kW 75kW 90kW 125kW 190kW 220kW<br />

75A 85A 105A 125A 150A 180A 250A<br />

-<br />

300A 400A<br />

-<br />

630A 800A<br />

37kW 45kW 55kW 60kW 75kW 90kW 132kW 160kW 200kW 330kW 440kW<br />

75A 85A 105A 120A 150A 180A 250A<br />

-<br />

300A 400A<br />

-<br />

630A 800A<br />

37kW 45kW 55kW 60kW 90kW 110kW 132kW 160kW 225kW 330kW 500kW<br />

64A 75A 85A 90A 140A 180A 200A<br />

-<br />

250A 350A<br />

-<br />

500A 720A<br />

2NO2NC 2NO2NC 2NO2NC 2NO2NC 2NO2NC 2NO2NC 2NO2NC - 2NO2NC 2NO2NC - 2NO2NC 2NO2NC<br />

unting<br />

le<br />

Mounting<br />

hole<br />

Mounting<br />

hole<br />

Mounting<br />

hole<br />

Mounting<br />

Mounting<br />

hole<br />

hole<br />

Mounting<br />

hole<br />

Mounting<br />

hole<br />

Mounting<br />

Mounting<br />

hole<br />

hole<br />

Mounting<br />

Mounting<br />

Mounting<br />

hole<br />

hole<br />

hole<br />

Mounting<br />

Mounting<br />

Mounting<br />

hole<br />

hole<br />

hole<br />

Mounting<br />

hole<br />

1.12 3.4 4 7.9 -<br />

11.8 -<br />

28<br />

94×181.5×115.7 114×231.4×146.5 120×206.4×157 138×306.54×181 - 163×380×198 -<br />

360×530×262<br />

× × ◦ -<br />

◦ -<br />

◦<br />

183


Meta-MEC and Metasol relays comparison table<br />

Metasol<br />

MR<br />

Type<br />

Auxiliary<br />

Rated current (A)<br />

AC15<br />

(kW)<br />

120 V<br />

240 V<br />

MR-4 MR-6 MR-8<br />

4NO, 3NO1NC, 2NO2NC 6NO, 5NO1NC, 4NO2NC 8NO, 7NO1NC, 6NO2NC<br />

1NO3NC, 4NC 3NO3NC, 2NO4NC 5NO3NC, 4NO4NC<br />

6 6 6<br />

3 3 3<br />

Manufactured products<br />

Mounting size<br />

49.5~65<br />

32~35<br />

Mounting<br />

hole 32~35<br />

49.5~65<br />

Mounting<br />

hole 32~35<br />

49.5~65<br />

Mounting<br />

hole<br />

Demension (W×H×D)<br />

Weight (kg)<br />

Type<br />

GMR Auxiliary (kW)<br />

Rated current (A) AC110V<br />

AC11<br />

AC220V<br />

45×73.5×79(96.6) 45×73.5×109.6(127.2) 45×73.5×109.6(127.2)<br />

0.284 0.315 0.339<br />

GMR-4(D) GMR-6(D) GMR-8(D)<br />

4NO, 3NO1NC, 2NO2NC 6NO, 5NO1NC, 4NO2NC 8NO, 7NO1NC, 6NO2NC<br />

1NO3NC, 4NC 3NO3NC, 2NO4NC 5NO3NC, 4NO4NC<br />

6 6 6<br />

5 5 5<br />

Discontinued priducts<br />

Mounting size<br />

Mounting<br />

hole<br />

Mounting<br />

hole<br />

Mounting<br />

hole<br />

Demension (W×H×D)<br />

Weight (kg)<br />

44×80×86.8(113.2) 44×80×118.6(145) 44×80×118.6(145)<br />

0.34(0.56) 0.37(0.59) 0.39(0.61)<br />

184


Meta-MEC and Metasol TOR comparison table<br />

Manufactured products<br />

MT<br />

MT-12 0.14(0.1~0.16), 0.21(0.16~0.25), 0.33(0.25~0.4),<br />

0.52(0.4~0.63), 0.82(0.63~1), 1.3(1~1.6), 2.1(1.6~2.5),<br />

3.3(2.5~4), 5(4~6), 6.5(5~8), 7.5(6~9), 8.5(7~10), 11(9~13),<br />

15(12~18), 19(16~22)<br />

MT-32 0.14(0.1~0.16), 0.21(0.16~0.25), 0.33(0.25~0.4),<br />

0.52(0.4~0.63), 0.82(0.63~1), 5(4~6), 6.5(5~8), 7.5(6~9),<br />

8.5(7~10), 11(9~13), 15(12~18), 19(16~22), 22(18~26),<br />

34(28~40)<br />

MT-63 5(4~6), 6.5(5~8), 7.5(6~9), 8.5(7~10), 11(9~13), 15(12~18),<br />

19(16~22), 22(18~26), 30(24~36), 34(28~40), 42(34~50),<br />

54(45~65)<br />

MT-95 8.5(7~10), 11(9~13), 15(12~18), 19(16~22), 22(18~26),<br />

30(24~36), 34(28~40), 42(34~50), 54(45~65), 65(54~75),<br />

74(63~85), 83(70~95), 90(80~100)<br />

MT-150 42(34~50), 55(45~65), 65(54~75), 74(63~85), 93(80~105),<br />

113(95~130), 130(110~150)<br />

MT-225 80(65~100), 107(85~125), 130(100~160), 153(120~185),<br />

200(160~240)<br />

MT-400 107(85~125), 130(100~160), 153(120~185), 200(160~240),<br />

265(200~330), 350(260~400)<br />

MT-800 265(200~300), 350(260~400), 515(400~630), 660(520~800)<br />

Discontinued priducts<br />

GTH (K)<br />

GTH(K)-22 0.14(0.1~0.16), 0.21(0.16~0.25), 0.33(0.25~0.4),<br />

0.52(0.4~0.63), 0.82(0.63~1), 1.3(1~1.6), 2.1(1.6~2.5),<br />

3.3(2.5~4), 5(4~6), 6.5(5~8), 7.5(6~9), 8.5(7~10), 11(9~13),<br />

15(12~18), 19(16~22)<br />

GTH(K)-40 5(4~6), 6.5(5~8), 7.5(6~9), 8.5(7~10), 11(9~13), 15(12~18),<br />

19(16~22), 22(18~26), 30(24~36), 34(28~40)<br />

GTH(K)-85 8.5(7~10), 11(9~13), 15(12~18), 19(16~22), 22(18~26),<br />

30(24~36), 34(28~40), 42(34~50), 55(45~65), 65(54~75),<br />

74(63~85)<br />

GTH(K)-100 41(34~50), 48(39~57), 56(43~65), 67(54~80), 80(65~100),<br />

107(85~125)<br />

GTH(K)-150 41(34~50), 48(39~57), 56(43~65), 67(54~80), 80(65~100),<br />

107(85~125), 130(100~150)<br />

45<br />

GTH(K)-220 80(65~100), 107(85~125), 130(100~160), 150(120~180),<br />

200(160~240)<br />

GTH(K)-400 107(85~125), 130(100~160), 150(120~180), 200(160~240),<br />

250(200~300), 350(260~400)<br />

GTH(K)-600 250(200~300), 350(260~400), 500(400~600), 660(520~800)<br />

9.6<br />

Compatibility bracket<br />

- Mounting Metasol MC on Din-Rail of braket after install the bracket on panel<br />

- Please use compatibility bracket when replace from Meta-MEC to Metasol MC without to change of panel size<br />

70<br />

15.2<br />

45<br />

9.6<br />

68<br />

110<br />

68<br />

Manufactured products<br />

Discontinued priducts<br />

MP-40<br />

MC-32a~40a<br />

GMC-32~40<br />

MP-85<br />

MC-50a~85a<br />

GMC-50~85<br />

185<br />

70<br />

15.2


Certifications<br />

186<br />

Type<br />

Metasol<br />

<strong>Contactor</strong>s<br />

Thermal<br />

<strong>Overload</strong><br />

Relays<br />

Nondifferential<br />

(2-heater)<br />

Thermal<br />

<strong>Overload</strong><br />

Relays<br />

Nondifferential<br />

(3-heater)<br />

Thermal<br />

<strong>Overload</strong><br />

Relays<br />

Differential<br />

Thermal<br />

<strong>Overload</strong><br />

Relays<br />

Class 20<br />

Note) ●: Completion<br />

Type<br />

Cerficate<br />

Mark<br />

and<br />

name<br />

MC-6a<br />

MC-9a<br />

MC-12a<br />

MC-18a<br />

MC-9b<br />

MC-12b<br />

MC-18b<br />

MC-22b<br />

MC-32a<br />

MC-40a<br />

MC-50a<br />

MC-65a<br />

MC-75a<br />

MC-85a<br />

MC-100a<br />

MC-130a<br />

MC-150a<br />

MC-185a<br />

MC-225a<br />

MC-265a<br />

MC-330a<br />

MC-400a<br />

MC-500a<br />

MC-630a<br />

MC-800a<br />

MT-12/2H<br />

MT-32/2H<br />

MT-63/2H<br />

MT-95/2H<br />

MT-150/2H<br />

MT-225/2H<br />

MT-400/2H<br />

MT-800/2H<br />

MT-12/3H<br />

MT-32/3H<br />

MT-63/3H<br />

MT-95/3H<br />

MT-150/3H<br />

MT-225/3H<br />

MT-400/3H<br />

MT-800/3H<br />

MT-12/3K<br />

MT-32/3K<br />

MT-63/3K<br />

MT-95/3K<br />

MT-150/3K<br />

MT-225/3K<br />

MT-400/3K<br />

MT-800/3K<br />

MT-12/3D<br />

MT-32/3D<br />

MT-63/3D<br />

MT-95/3D<br />

MT-150/3D<br />

MT-225/3D<br />

MT-400/3D<br />

MT-800/3D<br />

Approvals<br />

Certificates<br />

- IEC UL CSA GB IEC KEPIC<br />

CE U.S.A & cUL CSA CCC KEMA DEMKO<br />

Korea Europe U.S.A & Canada Canada China Netherlands Denmark Korea<br />

● ● ● ● ● ● ●<br />

● ● ● ● ● ● ●<br />

● ● ● ● ● ● ●<br />

● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ●<br />

● ● ● ● ● ● ●<br />

● ● ● ● ● ● ●<br />

● ● ● ● ● ● ●<br />

● ● ● ● ● ● ●<br />

● ● ● ● ● ● ●<br />

● ● ● ● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ● ●<br />

● ● ● ● ●<br />

● ● ● ● ●<br />

● ● ● ● ●<br />

● ● ● ● ●<br />

● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ●<br />

● ● ● ●<br />

● ● ● ●<br />

● ● ● ●<br />

● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ●<br />

● ● ● ●<br />

● ● ● ●<br />

● ● ● ●<br />

● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ●<br />

● ● ● ●<br />

● ● ● ●<br />

● ● ● ●<br />

● ● ●<br />

● ● ● ● ●<br />

● ● ● ● ●<br />

● ● ● ● ●<br />

● ● ●<br />

● ● ●<br />

● ● ●<br />

● ● ●


1867<br />

Marine certifications<br />

Type<br />

Approvals<br />

Type<br />

Metasol<br />

<strong>Contactor</strong>s<br />

Thermal<br />

<strong>Overload</strong><br />

Relays<br />

Nondifferential<br />

(2-heater)<br />

Thermal<br />

<strong>Overload</strong><br />

Relays<br />

Nondifferential<br />

(3-heater)<br />

Thermal<br />

<strong>Overload</strong><br />

Relays<br />

Differential<br />

Thermal<br />

<strong>Overload</strong><br />

Relays<br />

Class 20<br />

Note) ●: Completion<br />

Mark<br />

and<br />

name<br />

MC-6a<br />

MC-9a<br />

MC-12a<br />

MC-18a<br />

MC-9b<br />

MC-12b<br />

MC-18b<br />

MC-22b<br />

MC-32a<br />

MC-40a<br />

MC-50a<br />

MC-65a<br />

MC-75a<br />

MC-85a<br />

MC-100a<br />

MC-130a<br />

MC-150a<br />

MC-185a<br />

MC-225a<br />

MC-265a<br />

MC-330a<br />

MC-400a<br />

MC-500a<br />

MC-630a<br />

MC-800a<br />

MT-12/2H<br />

MT-32/2H<br />

MT-63/2H<br />

MT-95/2H<br />

MT-150/2H<br />

MT-225/2H<br />

MT-400/2H<br />

MT-800/2H<br />

MT-12/3H<br />

MT-32/3H<br />

MT-63/3H<br />

MT-95/3H<br />

MT-150/3H<br />

MT-225/3H<br />

MT-400/3H<br />

MT-800/3H<br />

MT-12/3K<br />

MT-32/3K<br />

MT-63/3K<br />

MT-95/3K<br />

MT-150/3K<br />

MT-225/3K<br />

MT-400/3K<br />

MT-800/3K<br />

MT-12/3D<br />

MT-32/3D<br />

MT-63/3D<br />

MT-95/3D<br />

MT-150/3D<br />

MT-225/3D<br />

MT-400/3D<br />

MT-800/3D<br />

KR LR BV GL DNV ABS NK RINA<br />

Korea U.K France Germany Norway U.S.A Japan Italy<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

● ● ● ● ● ● ● ●<br />

187


Safety Instructions<br />

•For your safety, please read user's manual thoroughly before operating.<br />

•Contact the nearest authorized service facility for examination, repair, or adjustment.<br />

•Please contact qualified service technician when you need maintenance.<br />

Do not disassemble or repair by yourself!<br />

•Any maintenance and inspection shall be performed by the personnel having expertise concerned.<br />

c 2016.07 <strong>LSIS</strong> Co.,Ltd. All rights reserved.<br />

www.<strong>LSIS</strong>.com/usa<br />

■ <strong>LSIS</strong> usa Inc. Chicago Branch<br />

2000 Millbrook Drive Lincolnshire, IL 60069<br />

Tel : 847-941-8240~59 sales.us@lsis.com<br />

Fax. 82-2-2034-4555<br />

■ HEAD OFFICE<br />

LS-ro 127 (Hogye-dong) Dongan-gu, Anyang-si,<br />

Gyeonggi-Do Korea<br />

Tel. 82-2-2034-4902, 4684, 4429 Fax. 82-2-2034-4555<br />

■ GLOBAL NETWORK<br />

Overseas Subsidiaries<br />

•<strong>LSIS</strong> USA Inc. ≫ Chicago, America<br />

2000 Millbrook Drive, Lincolnshire, Chicago, IL 60069, United States of America<br />

Tel: 1-847-941-8240 Fax: 1-847-941-8259 E-mail: seungheonc@lsis.com<br />

•<strong>LSIS</strong> (Middle East) FZE ≫ Dubai, U.A.E.<br />

LOB 19-205, JAFZA View Tower, Jebel Ali Free Zone, Dubai, United Arab Emirates<br />

Tel: 971-4-886-5360 Fax: 971-4-886-5361 E-mail: hschoib@lsis.com<br />

•<strong>LSIS</strong> Europe B.V. ≫ Schiphol-Rijk, Netherlands<br />

1st Floor, Tupoleviaan 48, 1119NZ, Schiphol-Rijk, The Netherlands<br />

Tel: 31-20-654-1420 Fax: 31-20-654-1429 E-mail: junshickp@lsis.com<br />

•<strong>LSIS</strong> Japan Co., Ltd. ≫ Tokyo, Japan<br />

Tokyo Club Building 13F, 2-6, Kasumigaseki 3-chome, Chiyoda-ku, Tokyo, 100-0013<br />

Tel: 81-3-6268-8241 Fax: 81-3-6268-8240 E-mail: jschuna@lsis.com<br />

•<strong>LSIS</strong>(Dalian) Co., Ltd. ≫ Dalian, China<br />

No. 15, Liaohexi 3-Road, Economic and Technical Development Zone, Dalian 116600, China<br />

Tel: 86-411-8273-7777 Fax: 86-411-8730-7560 E-mail: tangyh@lsis.com<br />

• LS IS(Wuxi) Co., Ltd. ≫ WUxi, China<br />

102-A , National High & New Tech Industrial Development Area, Wuxi, Jiangsu, 214028, P.R.China<br />

Tel: 86-510-8534-6666 Fax: 86-510-522-4078 E-mail: wangzy@lsis.com<br />

•LS-Vina Co., Ltd. ≫ Hanoi, Vietnam<br />

Nguyen Khe, Dong Anh, Hanoi, Vietnam<br />

Tel: 84-4-6275-8055 Fax: 84-4-3882-0220 E-mail: sjbaik@lsis.com<br />

Specifications in this catalog are subject to change without notice due to<br />

continuous product development and improvement.<br />

2017. 02<br />

Overseas Branches<br />

•<strong>LSIS</strong> Co., Ltd, Indonesia<br />

APL TOWER lantai 10 unit 3, Jl. Letjen S. Parman Kav. 28, 11470, Jakarta Barat, Indonesia<br />

Tel: 62-21-2933-7614 Fax: 62-21-2933-7624 E-mail: dioh@lsis.com<br />

•<strong>LSIS</strong> Moscow Office, Russia<br />

123610, Krasnopresnenskaya, nab, 12, building1, office No.1005, Moscow, Russia<br />

Tel: 7-495-258-1466, 1467 Fax: 7-495-258-1466, 1467 E-mail: jdpark1@lsis.com<br />

<strong>Contactor</strong>s and <strong>Overload</strong> relays (E) 2016. 07/(02) 2017.02 Printed in Korea STAFF


www.lsis.biz<br />

Meta-MEC<br />

Mini <strong>Contactor</strong>s and<br />

<strong>Overload</strong> Relays


Customer satisfaction with world-class<br />

products and services :<br />

<strong>LSIS</strong> is committed to excellence!<br />

We are committed to global product development,<br />

driving future growth, and expanding<br />

the overseas market share, as well as consolidating<br />

existing business. Join us in a future where <strong>LSIS</strong> will<br />

become a genuine global leader.<br />

2I


Contents<br />

Features 04<br />

Catalog numbering system 10<br />

Quick selection table 11<br />

AC coil 12<br />

DC coil 14<br />

Motor starters, open 16<br />

Mini contactors, Reversing type 17<br />

Bimetallic style <strong>Overload</strong> Relays 21<br />

<strong>Contactor</strong>s relays 23<br />

Auxiliary contact 25<br />

Accessories 27<br />

Dimensions 32<br />

I3


Compact & Space Saving<br />

LS Mini contactors & starters<br />

LS Mini contactors and starters are suitable for the switching and protection<br />

of small motors up to 7.5kW, lights and electric heating circuits.<br />

KEMA type tested as the global product that meets international standards<br />

such as UL, CCC, Safe Certification and CE.<br />

LS Mini -contactors and starters<br />

Suitable for the switching and protection of motors, capacitor banks, lights, etc.<br />

in AC circuit.<br />

Providing the convenience of connection and mounting by terminal options such as Cage<br />

clamp, Fast-on, Solder pin as well as Screw Terminal. In addition dedicated thermal style<br />

overload realys can be easily attached for motor protection and various accessories are<br />

also available - surge unit, timer unit, auxiliary contact unit.<br />

Can be driven from the output of PLC :<br />

low power consumption type contactor is available for this purpose, which requires no relay<br />

between contactor and PLC.<br />

4I


Environmental conditions<br />

Ambient temperature: -5 ~ 40℃<br />

(standard 20℃)<br />

Max. temp. inside a panel: 55℃<br />

Relative humidity: 45 ~ 85% RH<br />

Altitude: max. 2,000m<br />

Vibration: 10 ~ 55Hz, 2g<br />

Shock resistance: 5g<br />

Storage temperature: -30 ~ 65℃<br />

Reference standards<br />

IEC 60947-4<br />

UL 508<br />

Certification<br />

ISO 9001, ISO 14001<br />

UL, CE, safety certification, CCC<br />

I5


Low Consumption<br />

The low power consumption type contactor, a product that<br />

combines the advantages of the relay and the magnetic contactor,<br />

can be driven directly by the small output of the PLC. The relay<br />

and its space in the panel are not necessary any more.<br />

Direct driving by<br />

PLC output contact<br />

Photoelectric switch, proximity switch . . .<br />

Transistor output of various detection<br />

AC 380V<br />

7.5kW<br />

16A<br />

or under<br />

Direct driving by PLC output<br />

Mini contactor<br />

Low-power consumption<br />

type<br />

Directly operable by the low output<br />

signal from the devices such as PLC,<br />

photoelectric switches and proximity<br />

limit switches, etc.<br />

So the driving of 3-phase induction<br />

motor can be done without using an<br />

intermediate relay .<br />

Conventional device<br />

6I


PLC<br />

Remote I/O<br />

unit<br />

◀<br />

+<br />

Conventional style<br />

(Relay + <strong>Contactor</strong>)<br />

Inverter<br />

Servo motor<br />

operation<br />

Lighting<br />

circuits<br />

Reduction rate of power consumption<br />

86%<br />

1.2W<br />

DC coil<br />

Low consumption<br />

type<br />

9W<br />

Regular<br />

type<br />

67%<br />

2W<br />

AC coil<br />

Low consumption<br />

type<br />

9W<br />

Regular<br />

type<br />

Characteristic of control coil<br />

Coil Type<br />

AC coil<br />

DC<br />

(50/60Hz) Regular Wide Low consumption<br />

Power consumption (W) 2 3 2 1.2<br />

Control voltage (V) 24~550 12~250<br />

Operation<br />

voltage<br />

(%)<br />

Operation<br />

time<br />

(ms)<br />

12, 20, 24, 48, 12, 20, 24,48,<br />

72, 110, 120 72, 110, 120<br />

Pick-up 80 or under 75 or under 70 or under 75 or under<br />

Release 30 or over 12 or over 12 or over 12 or over<br />

Coil ON <br />

Contact ON<br />

Coil OFF <br />

Contact OFF<br />

20 or under 50 or under 50 or under 50 or under<br />

45 or under 45 or under 45 or under 45 or under<br />

I7


Convenience<br />

4 terminal options for a variety of applications<br />

Screw<br />

Fast-on<br />

Cage clamp<br />

Solder pin<br />

GMC-M<br />

GMC-MF<br />

GMC-MC<br />

GMC-MP<br />

Screw terminal<br />

Standard type with M3 screw for connetion<br />

with a ring or U type terminal<br />

Fast-on terminal<br />

Plug-in style for connection with a quickconnector.<br />

(2.8 0.8t/6.3 0.8t common)<br />

Cage clamp terminal<br />

suitable for connection with wires directly<br />

Auxiliary contact units<br />

Item Screw Fast-on Cage clamp Solder pin<br />

Side mount<br />

2-p,<br />

Front mount<br />

×<br />

Solder pin terminal<br />

for mounting on PCB<br />

4-p,<br />

Front mount<br />

×<br />

8I


Variety<br />

Accessories ...<br />

Solder pin terminal<br />

for aux. contact<br />

Solder pin terminal<br />

for main. contact<br />

Solder pin terminal<br />

for aux. contact<br />

Aux. contact unit,<br />

AU-2M<br />

2-p for front mount<br />

Aux. contact unit,<br />

AU-1M<br />

1-p for side mount<br />

Aux. contact unit,<br />

AU-1M<br />

1-p for side mount<br />

Aux. contact unit,<br />

AU-4M<br />

4-p for front mount<br />

Timer unit, AT-12M<br />

Electronic type<br />

for On-Off-Delay<br />

Surge absorber<br />

unit, AS-12M<br />

Thermal overload relay,<br />

GTH-12M<br />

Separate mounting unit, AZ-12MH<br />

for overload relay, GTH-12M<br />

Surge absorber unit<br />

Timer unit<br />

Relay separate<br />

mounting unit<br />

Solder pin<br />

terminal<br />

Interlock unit<br />

I9


Catalog numbering system<br />

<strong>Contactor</strong>s & Starters<br />

/<br />

GM C 12 M R<br />

F AP<br />

/<br />

<strong>Contactor</strong> / Starter<br />

Nominal rating<br />

Mini contactor<br />

Terminal type of Mini contactor<br />

6 6A<br />

9 9A<br />

12 12A<br />

16 16A<br />

None<br />

P<br />

F<br />

C<br />

Screw<br />

Pin<br />

Fast-on<br />

Cage clamp<br />

Device type<br />

Combination<br />

No. of pole<br />

C<br />

<strong>Contactor</strong> with AC coil<br />

None<br />

Without additional device<br />

None<br />

3pole<br />

D<br />

<strong>Contactor</strong> with DC coil<br />

R<br />

Reversing<br />

4P<br />

4pole<br />

S<br />

Starter, open<br />

Thermal overload relay<br />

GT K / 12 M -<br />

-<br />

Thermal overload relay<br />

Setting range (A)<br />

Mini contactor<br />

Mounting<br />

12 0.1~16A<br />

None<br />

H<br />

Standard<br />

(mount to contactor)<br />

Separate mount<br />

K<br />

H<br />

Protection type<br />

Differential<br />

current protection<br />

Non-differential<br />

Number of bimetal element<br />

for Non-differential H type<br />

None 2 elements<br />

3 3 elements<br />

2-pole <strong>Contactor</strong>s<br />

GMC<br />

- 10P 2 / TS BQ<br />

110V<br />

Magnetic<br />

Ampere frame (A)<br />

Number of poles<br />

Terminal connection<br />

Coil connection<br />

Operational voltage (AC)<br />

contactors<br />

10P 10<br />

2 2Pole<br />

TS<br />

Screw clamp<br />

BS<br />

Screw clamp<br />

20V<br />

24V<br />

20P 20<br />

TQ<br />

Quick connect<br />

BQ<br />

Quick connect<br />

48V 24~240V<br />

25P 25<br />

110V 100~120V<br />

30P 30<br />

220V 208~240V<br />

35P 35<br />

40P 40<br />

10


Quick selection table<br />

Mini contactors<br />

3NO main contacts<br />

1 auxiliary contacts<br />

Screw clamp type Fast-on type Cage clamp type Solder pin type<br />

Frame size 6A 9A 12A 16A<br />

Screw clamp type AC coil GMC-6M GMC-9M GMC-12M GMC-16M<br />

DC coil GMD-6M GMD-9M GMD-12M GMD-16M<br />

Fast-on type AC coil GMC-6MF GMC-9MF GMC-12MF GMC-16MF<br />

DC coil GMD-6MF GMD-9MF GMD-12MF GMD-16MF<br />

Cage clamp type AC coil GMC-6MC GMC-9MC GMC-12MC GMC-16MC<br />

DC coil GMD-6MC GMD-9MC GMD-12MC GMD-16MC<br />

Solder pin type AC coil GMC-6MP GMC-9MP GMC-12MP GMC-16MP<br />

DC coil GMD-6MP GMD-9MP GMD-12MP GMD-16MP<br />

Ratings / IEC60947-4 kW A kW A kW A kW A<br />

AC1 20 20 20 20<br />

AC3 200/240V 1.5 7 2.2 9 3 12 4 15<br />

380/440V 2.2 6 4 9 5.5 12 7.5 16<br />

500/550V 3 5 3.7 6 4 7 5.5 9<br />

690V 3 4 4 5 4 5 4 5<br />

Ratings / UL508 hp A hp A hp A hp A<br />

continuous current Ith = 20A (maximum for cage clamp type is 10A)<br />

single phase 120V 1/2 1/2 1 * -<br />

230V/240V 1 1.5 2 ** -<br />

three phase 240V 1.5 3 3 -<br />

480V 3 5 7.5 *** -<br />

600V 3 5 7.5 -<br />

Wire Range : Copper, 75°C, Stranded, 18-12AWG<br />

NEMA size 00 00 00 0<br />

Additional auxiliary contacts<br />

Screw clamp type Fast-on type Cage clamp type Solder pin type<br />

2-pole, Front mount<br />

AU-2M<br />

AU-2MF<br />

AU-2MC<br />

4-pole, Front mount<br />

AU-4M<br />

AU-4MF<br />

AU-4MC<br />

AU-1MP<br />

2-pole, Side mount<br />

AU-1M<br />

AU-1MF<br />

AU-1MC<br />

Note) * = 1/2 for cage clamp type, ** = 1.5hp for cage clamp type, *** = 5hp for cage clamp type<br />

16AF : not approved from UL<br />

<strong>Overload</strong> Relays<br />

Bimetallic style<br />

Type GT<br />

Class 10A<br />

GT-12M<br />

Setting<br />

ranges<br />

(A)<br />

0.1 - 0.16<br />

0.16 - 0.25<br />

0.25 - 0.4<br />

0.4 - 0.63<br />

0.63 - 1<br />

1 - 1.6<br />

1.6 - 2.5<br />

2.5 - 4<br />

4 - 6<br />

5 - 8<br />

6 - 9<br />

7 - 10<br />

9 - 13<br />

12 - 16<br />

Base for<br />

separate mount<br />

Differential<br />

Non-differential (3-heater)<br />

Non-differential (2-heater)<br />

GTK-12M<br />

GTH-12M/3<br />

GTH-12M<br />

11


AC coil<br />

<strong>Contactor</strong>s<br />

Circuit diagram<br />

3-Pole contactors<br />

- For motor control<br />

- 3 main plus 1 auxiliary contacts<br />

- Coil voltage : AC<br />

A1<br />

A2<br />

1/L1 3/L2 5/L3 13<br />

2/T1 4/T2 6/T3<br />

14<br />

Screw clamp connection types<br />

AC3 ratings (IEC60947-4) AC1 Auxiliary<br />

Frame size 220 ~ 380 ~ 500 ~<br />

rating contact Type<br />

690V<br />

240V 440V 550V Ith (standard)<br />

6A<br />

1.5kW 2.2kW 3kW 3kW<br />

1NO or<br />

20A<br />

7A 6A 5A 4A 1NC<br />

GMC-6M<br />

9A<br />

2.2kW 4kW 3.7kW 4kW<br />

1NO or<br />

20A<br />

9A 9A 6A 5A 1NC<br />

GMC-9M<br />

12A<br />

3kW 5.5kW 4kW 4kW<br />

1NO or<br />

20A<br />

12A 12A 7A 5A 1NC<br />

GMC-12M<br />

16A<br />

4kW 7.5kW 5.5kW 4kW<br />

1NO or<br />

20A<br />

15A 16A 9A 5A 1NC<br />

GMC-16M<br />

Fast-on connection types<br />

AC3 ratings (IEC60947-4) AC1 Auxiliary<br />

Frame size 220 ~ 380 ~ 500 ~<br />

rating contact Type<br />

690V<br />

240V 440V 550V Ith (standard)<br />

6A<br />

1.5kW 2.2kW 3kW 3kW<br />

1NO or<br />

20A<br />

7A 6A 5A 4A 1NC<br />

GMC-6MF<br />

9A<br />

2.2kW 4kW 3.7kW 4kW<br />

1NO or<br />

20A<br />

9A 9A 6A 5A 1NC<br />

GMC-9MF<br />

12A<br />

3kW 5.5kW 4kW 4kW<br />

1NO or<br />

20A<br />

12A 12A 7A 5A 1NC<br />

GMC-12MF<br />

16A<br />

4kW 7.5kW 5.5kW 4kW<br />

1NO or<br />

20A<br />

15A 16A 9A 5A 1NC<br />

GMC-16MF<br />

Coil voltage, AC 50/60Hz<br />

24, 36, 42, 48, 110, 115, 120, 127, 200 / 208, 220, 220 / 230, 230 / 240, 256, 277, 380 / 400<br />

400, 440, 480, 500, 550V AC<br />

Performance (at 440VAC)<br />

Frame size 6A 9A 12A 16A<br />

Operation current 6A 9A 12A 16A<br />

Making current 72A 108A 144A 180A<br />

Breaking current 60A 90A 120A 150A<br />

Operation cycle<br />

1800 operations/hour<br />

Endurance Electrical : 1 mil. operations Mechanical : 12 mil. operations<br />

Note) 16A frame is not UL listed item.<br />

Certificate<br />

CE, ULCUL<br />

Coil characteristic<br />

Coil voltage<br />

AC<br />

Coil consumption (W) 2<br />

Inrush<br />

32VA<br />

Sealed<br />

6VA<br />

Closing voltage (%) 80~110<br />

Opening voltage (%) 30~40<br />

Closing time (ms) 10~20<br />

Opening time (ms) 35~45<br />

12


<strong>Contactor</strong>s<br />

Circuit diagram<br />

3-Pole contactors<br />

- For motor control<br />

- 3 main plus 1 auxiliary contacts<br />

- Coil voltage : AC<br />

A1<br />

A2<br />

1/L1 3/L2 5/L3 13<br />

2/T1 4/T2 6/T3<br />

14<br />

Cage clamp connection types<br />

AC3 ratings (IEC60947-4) AC1 Auxiliary<br />

Frame size 220 ~ 380 ~ 500 ~<br />

rating contact Type<br />

690V<br />

240V 440V 550V Ith (standard)<br />

6A<br />

1.5kW 2.2kW 3kW 3kW<br />

1NO or<br />

20A<br />

7A 6A 5A 4A 1NC<br />

GMC-6MC<br />

9A<br />

2.2kW 4kW 3.7kW 4kW<br />

1NO or<br />

20A<br />

9A 9A 6A 5A 1NC<br />

GMC-9MC<br />

12A<br />

3kW 5.5kW 4kW 4kW<br />

1NO or<br />

20A<br />

12A 12A 7A 5A 1NC<br />

GMC-12MC<br />

16A<br />

4kW 7.5kW 5.5kW 4kW<br />

1NO or<br />

20A<br />

15A 16A 9A 5A 1NC<br />

GMC-16MC<br />

Solder pin connection types<br />

Coil voltage, AC 50/60Hz<br />

24, 36, 42, 48, 110, 115, 120, 127, 200 / 208, 220, 220 / 230, 230 / 240, 256, 277, 380 / 400<br />

400, 440, 480, 500, 550V AC<br />

Ordering information<br />

Type, Auxiliary contact and Coil voltage<br />

AC3 ratings (IEC60947-4) AC1 Auxiliary<br />

Frame size 220 ~ 380 ~ 500 ~<br />

rating contact Type<br />

690V<br />

240V 440V 550V Ith (standard)<br />

6A<br />

9A<br />

12A<br />

16A<br />

1.5kW 2.2kW 3kW 3kW<br />

1NO or<br />

20A<br />

7A 6A 5A 4A 1NC<br />

2.2kW 4kW 3.7kW 4kW<br />

1NO or<br />

20A<br />

9A 9A 6A 5A 1NC<br />

3kW 5.5kW 4kW 4kW<br />

1NO or<br />

20A<br />

12A 12A 7A 5A 1NC<br />

4kW 7.5kW 5.5kW 4kW<br />

1NO or<br />

20A<br />

15A 16A 9A 5A 1NC<br />

GMC-6MP<br />

GMC-9MP<br />

GMC-12MP<br />

GMC-16MP<br />

Caution<br />

30。<br />

30。<br />

30。<br />

30。<br />

Prependicular plane<br />

Certificate<br />

CE, ULCUL<br />

(Fig.1)<br />

10<br />

(Fig.2)<br />

*Even installing direction takes the direction of Fig.1 to prependicular,<br />

ip to the direction of the 30。.<br />

Keep the distance more than 10mm with arc space shown Fig.2<br />

13


DC coil<br />

<strong>Contactor</strong>s<br />

Circuit diagram<br />

3-Pole contactors<br />

- For motor control<br />

- 3 main plus 1 auxiliary contacts<br />

- Coil voltage : DC<br />

A1<br />

A2<br />

1/L1 3/L2 5/L3 13<br />

2/T1 4/T2 6/T3<br />

14<br />

Screw clamp connection types<br />

AC3 ratings (IEC60947-4) AC1 Auxiliary<br />

Frame size 220 ~ 380 ~ 500 ~<br />

rating contact Type<br />

690V<br />

240V 440V 550V Ith (standard)<br />

6A<br />

1.5kW 2.2kW 3kW 3kW<br />

1NO or<br />

20A<br />

7A 6A 5A 4A 1NC<br />

GMD-6M<br />

9A<br />

2.2kW 4kW 3.7kW 4kW<br />

1NO or<br />

20A<br />

9A 9A 6A 5A 1NC<br />

GMD-9M<br />

12A<br />

3kW 5.5kW 4kW 4kW<br />

1NO or<br />

20A<br />

12A 12A 7A 5A 1NC<br />

GMD-12M<br />

16A<br />

4kW 7.5kW 5.5kW 4kW<br />

1NO or<br />

20A<br />

15A 16A 9A 5A 1NC<br />

GMD-16M<br />

Fast-on connection types<br />

Coil voltage, DC<br />

1 Standard type : 12, 20, 24, 36, 42, 48, 60, 72, 110, 120, 125, 220, 240, 250V DC<br />

2 Low consumption type : 12, 20, 24, 48, 72, 110, 120V DC(Low)<br />

3 Wide Voltage : 12, 20, 24, 48, 72, 110, 12V DC(Wide)<br />

Ordering information<br />

Type, Auxiliary contact and Coil voltage<br />

AC3 ratings (IEC60947-4) AC1 Auxiliary<br />

Frame size 220 ~ 380 ~ 500 ~<br />

rating contact Type<br />

690V<br />

240V 440V 550V Ith (standard)<br />

6A<br />

9A<br />

12A<br />

16A<br />

1.5kW 2.2kW 3kW 3kW<br />

1NO or<br />

20A<br />

7A 6A 5A 4A 1NC<br />

2.2kW 4kW 3.7kW 4kW<br />

1NO or<br />

20A<br />

9A 9A 6A 5A 1NC<br />

3kW 5.5kW 4kW 4kW<br />

1NO or<br />

20A<br />

12A 12A 7A 5A 1NC<br />

4kW 7.5kW 5.5kW 4kW<br />

1NO or<br />

20A<br />

15A 16A 9A 5A 1NC<br />

GMD-6MF<br />

GMD-9MF<br />

GMD-12MF<br />

GMD-16MF<br />

Certificate<br />

CE, ULCUL<br />

Coil characteristic<br />

Coil voltage<br />

DC<br />

Standard Low consumption Wide voltage<br />

Coil consumption (W) 3 1.2 2<br />

Inrush 3W 1.2W 2W<br />

Sealed 3W 1.2W 2W<br />

Closing voltage (%) 80~110 80~125 70~125<br />

Opening voltage (%) 10~30 10~30 10~30<br />

Closing time (ms) 40~50 40~50 40~50<br />

Opening time (ms) 35~45 35~45 35~45<br />

14


<strong>Contactor</strong>s<br />

Circuit diagram<br />

3-Pole contactors<br />

- For motor control<br />

- 3 main plus 1 auxiliary contacts<br />

- Coil voltage : DC<br />

A1<br />

A2<br />

1/L1 3/L2 5/L3 13<br />

2/T1 4/T2 6/T3<br />

14<br />

Cage clamp connection types<br />

AC3 ratings (IEC60947-4) AC1 Auxiliary<br />

Frame size 220 ~ 380 ~ 500 ~<br />

rating contact Type<br />

690V<br />

240V 440V 550V Ith (standard)<br />

6A<br />

1.5kW 2.2kW 3kW 3kW<br />

1NO or<br />

20A<br />

7A 6A 5A 4A 1NC<br />

GMD-6MC<br />

9A<br />

2.2kW 4kW 3.7kW 4kW<br />

1NO or<br />

20A<br />

9A 9A 6A 5A 1NC<br />

GMD-9MC<br />

12A<br />

3kW 5.5kW 4kW 4kW<br />

1NO or<br />

20A<br />

12A 12A 7A 5A 1NC<br />

GMD-12MC<br />

16A<br />

4kW 7.5kW 5.5kW 4kW<br />

1NO or<br />

20A<br />

15A 16A 9A 5A 1NC<br />

GMD-16MC<br />

Solder pin connection types<br />

AC3 ratings (IEC60947-4) AC1 Auxiliary<br />

Frame size 220 ~ 380 ~ 500 ~<br />

rating contact Type<br />

690V<br />

240V 440V 550V Ith (standard)<br />

6A<br />

9A<br />

12A<br />

16A<br />

Coil voltage, DC<br />

1 Standard type : 12, 20, 24, 36, 42, 48, 60, 72, 110, 120, 125, 220, 240, 250V DC<br />

2 Low consumption type : 12, 20, 24, 48, 72, 110, 120V DC(Low)<br />

3 Wide Voltage : 12, 20, 24, 48, 72, 110, 12V DC(Wide)<br />

Ordering information<br />

Type, Auxiliary contact and Coil voltage<br />

1.5kW 2.2kW 3kW 3kW<br />

1NO or<br />

20A<br />

7A 6A 5A 4A 1NC<br />

2.2kW 4kW 3.7kW 4kW<br />

1NO or<br />

20A<br />

9A 9A 6A 5A 1NC<br />

3kW 5.5kW 4kW 4kW<br />

1NO or<br />

20A<br />

12A 12A 7A 5A 1NC<br />

4kW 7.5kW 5.5kW 4kW<br />

1NO or<br />

20A<br />

15A 16A 9A 5A 1NC<br />

GMD-6MP<br />

GMD-9MP<br />

GMD-12MP<br />

GMD-16MP<br />

Caution<br />

30。<br />

30。<br />

30。<br />

30。<br />

Prependicular plane<br />

Certificate<br />

CE, ULCUL<br />

(Fig.1)<br />

10<br />

(Fig.2)<br />

*Even installing direction takes the direction of Fig.1 to prependicular,<br />

ip to the direction of the 30。.<br />

Keep the distance more than 10mm with arc space shown Fig.2<br />

15


Motor starters, open<br />

2.2kW<br />

~<br />

7.5kW<br />

Starters<br />

- Open types<br />

- Direct (Full voltage) types<br />

- Coil voltage : AC<br />

- <strong>Contactor</strong>s : screw clamp connection types<br />

- <strong>Overload</strong> relays : differential or non-differential types<br />

AC coil contactor + Differential type overload relay<br />

Devices combined<br />

AC3 ratings (IEC60947-4)<br />

Auxiliary Starter<br />

<strong>Contactor</strong> <strong>Overload</strong> 220 ~ 380 ~ 500 ~<br />

690V contacts Type<br />

(AC coil) (differential) 240V 440V 550V<br />

GMC-6M GTK-12M<br />

1.5kW 2.2kW 3kW 3kW 1NO or<br />

7A 6A 5A 4A 1NC<br />

GMS-6M/K<br />

GMC-9M GTK-12M<br />

2.2kW 4kW 3.7kW 4kW 1NO or<br />

9A 9A 6A 5A 1NC<br />

GMS-9M/K<br />

GMC-12M GTK-12M<br />

3kW 5.5kW 4kW 4kW 1NO or<br />

12A 12A 7A 5A 1NC<br />

GMS-12M/K<br />

GMC-16M GTK-12M<br />

4kW 7.5kW 5.5kW 4kW 1NO or<br />

15A 16A 9A 5A 1NC<br />

GMS-16M/K<br />

Certificate<br />

CE, ULCUL<br />

AC coil contactor + Non-differential type overload relay<br />

Devices combined<br />

Coil voltage, AC 50/60Hz<br />

24, 36, 42, 48, 110, 115, 120, 127, 200 / 208, 220, 220 / 230, 230 / 240, 256, 277, 380 / 400<br />

400, 440, 480, 500, 550V AC<br />

Ordering information<br />

Type, Auxiliary contact and Coil voltage<br />

<strong>Overload</strong> relay setting range<br />

AC3 ratings (IEC60947-4)<br />

<strong>Contactor</strong> <strong>Overload</strong> 220 ~ 380 ~ 500 ~<br />

(AC coil) (differential) 240V 440V 550V<br />

GMC-6M<br />

GMC-9M<br />

GMC-12M<br />

GMC-16M<br />

GTH-12M/3<br />

GTH-12M/3<br />

GTH-12M/3<br />

GTH-12M/3<br />

Auxiliary<br />

Starter<br />

690V contacts Type<br />

1.5kW 2.2kW 3kW 3kW 1NO or<br />

7A 6A 5A 4A 1NC<br />

2.2kW 4kW 3.7kW 4kW 1NO or<br />

9A 9A 6A 5A 1NC<br />

3kW 5.5kW 4kW 4kW 1NO or<br />

12A 12A 7A 5A 1NC<br />

4kW 7.5kW 5.5kW 4kW 1NO or<br />

15A 16A 9A 5A 1NC<br />

GMS-6M<br />

GMS-9M<br />

GMS-12M<br />

GMS-16M<br />

16


Mini contactors, Reversing type<br />

6A<br />

~<br />

16A<br />

/ AC coil<br />

Reversing contactors<br />

- For motor control<br />

- Mechanically interlocked<br />

- Coil voltage : AC<br />

Screw clamp connection types<br />

AC3 ratings (IEC60947-4) AC1 Auxiliary<br />

Frame size 220 ~ 380 ~ 500 ~<br />

rating contact Type<br />

690V<br />

240V 440V 550V Ith (standard)<br />

6A<br />

1.5kW 2.2kW 3kW 3kW<br />

1NO or<br />

20A<br />

7A 6A 5A 4A 1NC<br />

GMC-6MR<br />

9A<br />

2.2kW 4kW 3.7kW 4kW<br />

1NO or<br />

20A<br />

9A 9A 6A 5A 1NC<br />

GMC-9MR<br />

12A<br />

3kW 5.5kW 4kW 4kW<br />

1NO or<br />

20A<br />

12A 12A 7A 5A 1NC<br />

GMC-12MR<br />

16A<br />

4kW 7.5kW 5.5kW 4kW<br />

1NO or<br />

20A<br />

15A 16A 9A 5A 1NC<br />

GMC-16MR<br />

Fast-on connection types<br />

AC3 ratings (IEC60947-4) AC1 Auxiliary<br />

Frame size 220 ~ 380 ~ 500 ~<br />

rating contact Type<br />

690V<br />

240V 440V 550V Ith (standard)<br />

6A<br />

1.5kW 2.2kW 3kW 3kW<br />

1NO or<br />

20A<br />

7A 6A 5A 4A 1NC<br />

GMC-6MFR<br />

9A<br />

2.2kW 4kW 3.7kW 4kW<br />

1NO or<br />

20A<br />

9A 9A 6A 5A 1NC<br />

GMC-9MFR<br />

12A<br />

3kW 5.5kW 4kW 4kW<br />

1NO or<br />

20A<br />

12A 12A 7A 5A 1NC<br />

GMC-12MFR<br />

16A<br />

4kW 7.5kW 5.5kW 4kW<br />

1NO or<br />

20A<br />

15A 16A 9A 5A 1NC<br />

GMC-16MFR<br />

Certificate<br />

CE, ULCUL<br />

Coil voltage, AC 50/60Hz<br />

24, 36, 42, 48, 110, 115, 120, 127, 200 / 208, 220, 220 / 230, 230 / 240, 256, 277, 380 / 400<br />

400, 440, 480, 500, 550V AC<br />

Ordering information<br />

Type, Auxiliary contact and Coil voltage<br />

17


Mini contactors, Reversing type<br />

6A<br />

~<br />

16A<br />

/ AC coil<br />

Reversing contactors<br />

- For motor control<br />

- Mechanically interlocked<br />

- Coil voltage : AC<br />

Cage clamp connection types<br />

AC3 ratings (IEC60947-4) AC1 Auxiliary<br />

Frame size 220 ~ 380 ~ 500 ~<br />

rating contact Type<br />

690V<br />

240V 440V 550V Ith (standard)<br />

6A<br />

1.5kW 2.2kW 3kW 3kW<br />

1NO or<br />

20A<br />

7A 6A 5A 4A 1NC<br />

GMC-6MCR<br />

9A<br />

2.2kW 4kW 3.7kW 4kW<br />

1NO or<br />

20A<br />

9A 9A 6A 5A 1NC<br />

GMC-9MCR<br />

12A<br />

3kW 5.5kW 4kW 4kW<br />

1NO or<br />

20A<br />

12A 12A 7A 5A 1NC<br />

GMC-12MCR<br />

16A<br />

4kW 7.5kW 5.5kW 4kW<br />

1NO or<br />

20A<br />

15A 16A 9A 5A 1NC<br />

GMC-16MCR<br />

Solder pin connection types<br />

AC3 ratings (IEC60947-4) AC1 Auxiliary<br />

Frame size 220 ~ 380 ~ 500 ~<br />

rating contact Type<br />

690V<br />

240V 440V 550V Ith (standard)<br />

6A<br />

1.5kW 2.2kW 3kW 3kW<br />

1NO or<br />

20A<br />

7A 6A 5A 4A 1NC<br />

GMC-6MPR<br />

9A<br />

2.2kW 4kW 3.7kW 4kW<br />

1NO or<br />

20A<br />

9A 9A 6A 5A 1NC<br />

GMC-9MPR<br />

12A<br />

3kW 5.5kW 4kW 4kW<br />

1NO or<br />

20A<br />

12A 12A 7A 5A 1NC<br />

GMC-12MPR<br />

16A<br />

4kW 7.5kW 5.5kW 4kW<br />

1NO or<br />

20A<br />

15A 16A 9A 5A 1NC<br />

GMC-16MPR<br />

Certificate<br />

CE, ULCUL<br />

Coil voltage, AC 50/60Hz<br />

24, 36, 42, 48, 110, 115, 120, 127, 200 / 208, 220, 220 / 230, 230 / 240, 256, 277, 380 / 400<br />

400, 440, 480, 500, 550V AC<br />

Ordering information<br />

Type, Auxiliary contact and Coil voltage<br />

18


6A<br />

~<br />

16A<br />

/ DC coil<br />

Reversing contactors<br />

- For motor control<br />

- Mechanically interlocked<br />

- Coil voltage : DC<br />

Screw clamp connection types<br />

AC3 ratings (IEC60947-4) AC1 Auxiliary<br />

Frame size 220 ~ 380 ~ 500 ~<br />

rating contact Type<br />

690V<br />

240V 440V 550V Ith (standard)<br />

6A<br />

1.5kW 2.2kW 3kW 3kW<br />

1NO or<br />

20A<br />

7A 6A 5A 4A 1NC<br />

GMD-6MR<br />

9A<br />

2.2kW 4kW 3.7kW 4kW<br />

1NO or<br />

20A<br />

9A 9A 6A 5A 1NC<br />

GMD-9MR<br />

12A<br />

3kW 5.5kW 4kW 4kW<br />

1NO or<br />

20A<br />

12A 12A 7A 5A 1NC<br />

GMD-12MR<br />

16A<br />

4kW 7.5kW 5.5kW 4kW<br />

1NO or<br />

20A<br />

15A 16A 9A 5A 1NC<br />

GMD-16MR<br />

Fast-on connection types<br />

AC3 ratings (IEC60947-4) AC1 Auxiliary<br />

Frame size 220 ~ 380 ~ 500 ~<br />

rating contact Type<br />

690V<br />

240V 440V 550V Ith (standard)<br />

6A<br />

1.5kW 2.2kW 3kW 3kW<br />

1NO or<br />

20A<br />

7A 6A 5A 4A 1NC<br />

GMD-6MFR<br />

9A<br />

2.2kW 4kW 3.7kW 4kW<br />

1NO or<br />

20A<br />

9A 9A 6A 5A 1NC<br />

GMD-9MFR<br />

12A<br />

3kW 5.5kW 4kW 4kW<br />

1NO or<br />

20A<br />

12A 12A 7A 5A 1NC<br />

GMD-12MFR<br />

16A<br />

4kW 7.5kW 5.5kW 4kW<br />

1NO or<br />

20A<br />

15A 16A 9A 5A 1NC<br />

GMD-16MFR<br />

Certificate<br />

CE, ULCUL<br />

Coil voltage, DC<br />

1 Standard type : 12, 20, 24, 36, 42, 48, 60, 72, 110, 120, 125, 220, 240, 250V DC<br />

2 Low consumption type : 12, 20, 24, 48, 72, 110, 120V DC(Low)<br />

3 Wide Voltage : 12, 20, 24, 48, 72, 110, 12V DC(Wide)<br />

Ordering information<br />

Type, Auxiliary contact and Coil voltage<br />

19


Mini contactors, Reversing type<br />

6A<br />

~<br />

16A<br />

/ DC coil<br />

Reversing contactors<br />

- For motor control<br />

- Mechanically interlocked<br />

- Coil voltage : DC<br />

Cage clamp connection types<br />

AC3 ratings (IEC60947-4) AC1 Auxiliary<br />

Frame size 220 ~ 380 ~ 500 ~<br />

rating contact Type<br />

690V<br />

240V 440V 550V Ith (standard)<br />

6A<br />

1.5kW 2.2kW 3kW 3kW<br />

1NO or<br />

20A<br />

7A 6A 5A 4A 1NC<br />

GMD-6MCR<br />

9A<br />

2.2kW 4kW 3.7kW 4kW<br />

1NO or<br />

20A<br />

9A 9A 6A 5A 1NC<br />

GMD-9MCR<br />

12A<br />

3kW 5.5kW 4kW 4kW<br />

1NO or<br />

20A<br />

12A 12A 7A 5A 1NC<br />

GMD-12MCR<br />

16A<br />

4kW 7.5kW 5.5kW 4kW<br />

1NO or<br />

20A<br />

15A 16A 9A 5A 1NC<br />

GMD-16MCR<br />

Solder pin connection types<br />

AC3 ratings (IEC60947-4) AC1 Auxiliary<br />

Frame size 220 ~ 380 ~ 500 ~<br />

rating contact Type<br />

690V<br />

240V 440V 550V Ith (standard)<br />

6A<br />

1.5kW 2.2kW 3kW 3kW<br />

1NO or<br />

20A<br />

7A 6A 5A 4A 1NC<br />

GMD-6MSR<br />

9A<br />

2.2kW 4kW 3.7kW 4kW<br />

1NO or<br />

20A<br />

9A 9A 6A 5A 1NC<br />

GMD-9MSR<br />

12A<br />

3kW 5.5kW 4kW 4kW<br />

1NO or<br />

20A<br />

12A 12A 7A 5A 1NC<br />

GMD-12MSR<br />

16A<br />

4kW 7.5kW 5.5kW 4kW<br />

1NO or<br />

20A<br />

15A 16A 9A 5A 1NC<br />

GMD-16MSR<br />

Certificate<br />

CE, ULCUL<br />

Coil voltage, DC<br />

1 Standard type : 12, 20, 24, 36, 42, 48, 60, 72, 110, 120, 125, 220, 240, 250V DC<br />

2 Low consumption type : 12, 20, 24, 48, 72, 110, 120V DC(Low)<br />

3 Wide Voltage : 12, 20, 24, 48, 72, 110, 12V DC(Wide)<br />

Ordering information<br />

Type, Auxiliary contact and Coil voltage<br />

20


Bimetallic style <strong>Overload</strong> Relays<br />

Description<br />

GT-12M<br />

- Direct mount on the mini contactors with screw clamp connection.<br />

contactor types : GMC(D)-6M, GMC(D)-9M,<br />

GMC(D)-12M, GMC(D)-16M,<br />

- DIN rail or screw mountable with the optional base AZ-22H<br />

- Small physical size : 44 mm wide<br />

- 1NO+1NC trip contacts<br />

- Trip class 10A according to IEC60947-4-1<br />

- Differential current/Phase failure protection : GTK types<br />

- Non-differential GTH types are available for the economic solution<br />

- Ambient compensated -5 to 40 ℃<br />

- Manual/Automatic reset convertible.<br />

- Remote reset is optional<br />

- Trip free designed<br />

AZ-12H<br />

Separate<br />

mount<br />

GM-6M~16M<br />

Direct<br />

mount<br />

Catalog No.<br />

Setting ranges(A) Differential type Non-differential type<br />

3-heater 3-heater 2-heater<br />

0.1 - 0.16 GTK-12M0.14 GTH-12M/30.14 GTH-12M0.14<br />

0.16 - 0.25 GTK-12M0.21 GTH-12M/30.21 GTH-12M0.21<br />

0.25 - 0.4 GTK-12M0.33 GTH-12M/30.33 GTH-12M0.33<br />

0.4 - 0.63 GTK-12M0.52 GTH-12M/30.52 GTH-12M0.52<br />

0.63 - 1 GTK-12M0.82 GTH-12M/30.82 GTH-12M0.82<br />

1 - 1.6 GTK-12M1.3 GTH-12M/31.3 GTH-12M1.3<br />

1.6 - 2.5 GTK-12M2.1 GTH-12M/32.1 GTH-12M2.1<br />

2.5 - 4 GTK-12M3.3 GTH-12M/33.3 GTH-12M3.3<br />

4 - 6 GTK-12M5 GTH-12M/35 GTH-12M5<br />

5 - 8 GTK-12M6.5 GTH-12M/36.5 GTH-12M6.5<br />

6 - 9 GTK-12M7.5 GTH-12M/37.5 GTH-12M7.5<br />

7 - 10 GTK-12M8.5 GTH-12M/38.5 GTH-12M8.5<br />

9 - 13 GTK-12M12 GTH-12M/312 GTH-12M12<br />

12 - 16 GTK-12M14 GTH-12M/314 GTH-12M14<br />

GT-12M<br />

Certificate<br />

CE, ULCUL<br />

Auxiliary (Trip) contact rating<br />

AC15(11) duty<br />

Note) Values of (<br />

) are the ratings of NO contact under auto reset mode.<br />

DC13(11) duty<br />

110V 220V 550V 110V 220V<br />

2.5(0.3)A 2(0.3)A 1(0.3)A 0.28A 0.14A<br />

21


Bimetallic style <strong>Overload</strong> Relays<br />

Configuration of the front face<br />

Current<br />

setting<br />

Trip indication/Test<br />

Reset<br />

mode<br />

<br />

3-step current setting<br />

To set the current turn the setting dial using<br />

a crosshead screw driver.<br />

Trip indicator<br />

If the TOR is tripped, it protrudes by 2 to<br />

3mm to indicate the state. It can be used as<br />

a test trip button by pulling it manually.<br />

◀<br />

Manual mode, H<br />

Turn the reset dial into the “H”<br />

position and it will protrude.<br />

Automatic mode, A<br />

Press the reset dial and turn it<br />

counterclockwise to lock in the<br />

position “A”<br />

Manual / Auto reset selection<br />

Use a crosshead screw driver to switch the<br />

reset mode.<br />

Circuit diagram<br />

<strong>Overload</strong> Relay<br />

<strong>Contactor</strong>+<strong>Overload</strong> Relay<br />

22


<strong>Contactor</strong>s relays<br />

Description<br />

- 4-, 6-, 8-pole units - 44mm wide<br />

- Finger proof design - DIN rail or screw mountable<br />

- 16A continuous current, Ith - AC/DC control voltage<br />

Selection<br />

Poles<br />

Composition<br />

AC control<br />

Coil voltage, AC 50/60Hz<br />

24, 36, 42, 48, 110, 115, 120, 127, 200 / 208, 220, 220 / 230,<br />

230 / 240, 256, 277, 380 / 400, 400, 440, 480, 500, 550V AC<br />

Types<br />

DC control<br />

Coil voltage, DC<br />

1 Standard type : 12, 20, 24, 36, 42, 48, 60, 72, 110, 120, 125, 220, 240, 250V DC<br />

2 Low consumption type : 12, 20, 24, 48, 72, 110, 120V DC(Low)<br />

3 Wide Voltage : 12, 20, 24, 48, 72, 110, 12V DC(Wide)<br />

Remarks<br />

4 pole 4NO GMR-4M GMR-4MD Additional 2NO or 4NO<br />

3NO+1NC<br />

2NO+2NC<br />

auxiliary contact block can<br />

be mounted on these relays.<br />

1NO+3NC<br />

4NC<br />

6 pole 6NO GMR-6M GMR-6MD GMR-4M + AU-2M<br />

5NO+1NC<br />

4NO+2NC<br />

3NO+3NC<br />

2NO+4NC<br />

8 pole 8NO GMR-8M GMR-8MD GMR-4M + AU-4M<br />

7NO+1NC<br />

6NO+2NC<br />

5NO+3NC<br />

4NO+4NC<br />

Contact ratings<br />

Rated currents<br />

Making/Breaking currents<br />

Inductive load Resistive load Inductive load Resistive load<br />

AC duty 120V 6A 10A 66A 66A<br />

240V 3A 8A 33A 33A<br />

480V 1.5A 5A 16.5A 16.5A<br />

600V 1.2A 5A 13.2A 13.2A<br />

DC duty 125V 0.55A 5A 3.7A<br />

250V 0.27A 3A 1.8A<br />

440V 0.31A 2.5A 1.4A<br />

600V 0.1A 1A 0.7A<br />

Continuous current, Ith<br />

10A<br />

Note) Minimum voltage/current is 24V DC 10mA<br />

Performance<br />

Operation cycle<br />

1800 operations/hour<br />

Endurance Mechanical lifetime 20 mil. Operations<br />

Electrical AC15 duty 220V 0.5 mil. operations<br />

lifetime 440V 0.5 mil. operations<br />

AC12 duty 220V 0.25 mil. operations<br />

440V<br />

0.25 mil. operations<br />

DC13, 12 duty 24~220V 0.5 mil. operations<br />

23


<strong>Contactor</strong>s relays<br />

Circuit diagram<br />

GMR-4M<br />

GMR-6M<br />

(Note1) (Note1) (Note1) (Note1) (Note1)<br />

(Note2)<br />

(Note2)<br />

(Note2)<br />

(Note2)<br />

(Note2)<br />

GMR-8M<br />

Note) 1. AU-2M auxiliary contact unit<br />

2. AU-4M auxiliary contact unit<br />

3.In case of adding the auxiliary contact unit AU-2M or AU-4M onto the <strong>Contactor</strong> relay GMR-4M or 4DM<br />

please follow the contact configuration indicated in the table.<br />

How to add a auxiliary contact unit onto a contactor relay<br />

Adding<br />

Removing<br />

1 Set the unit onto the relay.<br />

2 Push the unit down.<br />

1 Pull the end of the hook of the unit with finger.<br />

2 Push the unit up.<br />

24


Auxiliary contact<br />

Front mount blocks<br />

Side mount blocks<br />

Screw clamp<br />

connection<br />

AU-4M, 4pole<br />

AU-1M, 1pole<br />

AU-2M, 2pole<br />

Fast-on<br />

connection<br />

AU-4MF, 4pole<br />

AU-1MF, 1pole<br />

AU-2MF, 2pole<br />

Cage clamp<br />

connection<br />

AU-4MC, 4pole<br />

AU-1MC, 1pole<br />

AU-2MC, 2pole<br />

Solder pin<br />

connection<br />

AU-1MS, 1pole<br />

25


Auxiliary contact<br />

Catalog No.<br />

Connection Applying Mounting<br />

type contactors type<br />

Composition<br />

Catalog no.<br />

Screw GMC-, GMD-, GMS- Front mount 2NO AU-2M20<br />

clamp 6M, 6MR 2NC AU-2M02<br />

9M, 9MR 1NO+1NC AU-2M11<br />

12M, 12MR 4NO AU-4M40<br />

16M, 16MR 3NO+1NC AU-4M31<br />

2NO+2NC<br />

1NO+3NC<br />

4NC<br />

AU-4M22<br />

AU-4M13<br />

AU-4M04<br />

Side mount 1NO AU-1M10<br />

1NC<br />

AU-1M01<br />

Fast-on GMC-, GMD-, GMS- Front mount 2NO AU-2MF20<br />

6MF, 6MRF 2NC AU-2MF02<br />

9MF, 9MRF 1NO+1NC AU-2MF11<br />

12MF, 12MRF 4NO AU-4MF40<br />

16MF, 16MRF 3NO+1NC AU-4MF31<br />

2NO+2NC<br />

1NO+3NC<br />

4NC<br />

AU-4MF22<br />

AU-4MF13<br />

AU-4MF04<br />

Side mount 1NO AU-1MF10<br />

1NC<br />

AU-1MF01<br />

Cage GMC-, GMD-, GMS- Front mount 2NO AU-2MC20<br />

clamp 6MC, 6MRC 2NC AU-2MC02<br />

9MC, 9MRC 1NO+1NC AU-2MC11<br />

12MC, 12MRC 4NO AU-4MC40<br />

16MC, 16MRC 3NO+1NC AU-4MC31<br />

2NO+2NC<br />

1NO+3NC<br />

4NC<br />

AU-4MC22<br />

AU-4MC13<br />

AU-4MC04<br />

Side mount 1NO AU-1MC10<br />

1NC<br />

AU-1MC01<br />

Solder pin GMC-, GMD-, GMS- Side mount 1NO AU-1MP10<br />

6MP, 6MRP 1NC AU-1MP01<br />

9MP, 9MRP<br />

12MP, 12MRP<br />

16MP, 16MRP<br />

26


Accessories<br />

Timer unit, AT-12M<br />

- Electronic type<br />

- ON/OFF time delay<br />

- Front mount<br />

Timer unit<br />

Surge absorber unit<br />

AT-12M<br />

AS-12M<br />

Electronic Timer<br />

Type Control voltage Delay Time Applied contactors<br />

AT-12M / IN AC/DC 24~48V ON 0.1~30s<br />

GMC-6M~16M<br />

GMD-6M~16M<br />

AT-12M / IF AC/DC 24~48V OFF 0.1~30s<br />

GMC-6M~16M<br />

GMD-6M~16M<br />

AT-12M / 2N AC 100~220V ON 0.1~30s<br />

GMC-6M~16M<br />

GMD-6M~16M<br />

AT-12M / 2F AC 100~220V OFF 0.1~30s<br />

GMC-6M~16M<br />

GMD-6M~16M<br />

1<br />

2<br />

Set the unit 1 onto the contactor and assemble<br />

it by sliding in the direction of 2 .<br />

To remove the unit from the contactor do it in<br />

reverse order.<br />

27


Accessories<br />

ON-delay Timer<br />

Used to delay the closing of the contactor between 1 to 30s.<br />

Operation sequence<br />

> 0.5s<br />

A1-A2<br />

Relay<br />

(15-18)<br />

Ts=1s-30s<br />

Setting a time as Ts=1s<br />

Relay<br />

(15-16)<br />

Ts=1s-30s<br />

Energized<br />

De-engerized<br />

Circuit diagram<br />

Application<br />

Setting a time as Ts=30s<br />

18 16 15 A1<br />

AC/DC 24-48V<br />

AC110-220V<br />

18 16 15 A1<br />

A2<br />

A2<br />

OFF-delay Timer<br />

Circuit<br />

A1-A2<br />

Setting a time as Ts=1s<br />

Switch<br />

(S1-S2)<br />

Relay<br />

(15-18)<br />

Ts=1s-30s<br />

Energized<br />

De-engerized<br />

Circuit diagram<br />

Application<br />

Setting a time as Ts=30s<br />

18<br />

15 S1 S2 A1<br />

AC/DC 24-48V<br />

AC110-220V<br />

A2<br />

18 15 S1 S2 A1<br />

A2<br />

18 15 S1 S2 A1<br />

A2<br />

Note) 1. Do not apply power to terminals S1 and S2.<br />

2. To entend S1 and S2 wires, use shield cable.<br />

28


Surge absorber unit, AS-12M<br />

- Coil surge suppressor<br />

AS-12M<br />

Surge absorber unit<br />

Type Internal element Operational voltage Applied contactors<br />

AS-12M / 1<br />

AC24~48V<br />

AS-12M / 2 AC60~127V GMC-6M~16M<br />

AS-12M / 3<br />

AC200~240V<br />

AS-12M / 4 Varistor DC12~24V<br />

AS-12M / 5<br />

DC30~72V<br />

AS-12M / 6<br />

DC100~127V<br />

GMD-6M~16M<br />

AS-12M / 7<br />

DC200~250V<br />

Separate mounting unit, AZ-12MH<br />

- To mount a relay separately from a contactor<br />

- Mountable on DIN rail or by screw fixing<br />

29


Accessories<br />

Direct adapter<br />

Used to mount a mini contactor to a Manual motor starter directly .<br />

Direct adapter type<br />

Type Manual motor starter + Mini contactor<br />

DA-16SA <strong>MMS</strong>-32S + GMC-6M~16M<br />

DA-16SD <strong>MMS</strong>-32S + GMD-6M~16M<br />

DA-16HA <strong>MMS</strong>-32H + GMC-6M~16M<br />

DA-16HD <strong>MMS</strong>-32H + GMD-6M~16M<br />

30


Interlock unit, AR-12M<br />

consists of<br />

- Mechanical interlock components<br />

- Cable kits for line and load sides<br />

Solder pin terminals<br />

To modify the connection to Solder pin type from Screw clamp type<br />

Available for contactors and auxiliary contact blocks<br />

DC Control<br />

AC Control<br />

31


Dimensions<br />

Mini contactors with Screw clamp type<br />

GMC-6M<br />

GMC-9M<br />

GMC-12M<br />

GMC-16M<br />

45<br />

M3.5(Coil terminal)<br />

M3.5<br />

57<br />

43.3<br />

4xM4(mouting Hole)<br />

37.7<br />

35<br />

4<br />

[mm]<br />

GMC-6M/4<br />

33.5<br />

58<br />

50<br />

GMC-9M/4<br />

GMC-12M/4<br />

GMC-16M/4<br />

7.6<br />

8.7<br />

7<br />

0.17kg<br />

GMD-6M<br />

GMD-9M<br />

GMD-12M<br />

45<br />

69<br />

55.3<br />

4xM4(mouting Hole)<br />

37.7<br />

35<br />

4<br />

GMD-16M<br />

GMD-6M/4<br />

GMD-9M/4<br />

33.5<br />

58<br />

M3.5(Coil terminal)<br />

M3.5<br />

50<br />

GMD-12M/4<br />

GMD-16M/4<br />

7.6<br />

8.7<br />

7<br />

0.23kg<br />

Circuit diagram<br />

GMC-6M~16M, GMD-6M~16M<br />

3-Pole contactors<br />

A1<br />

1/L1 3/L2 5/L3 13<br />

A1 1/L1<br />

3/L2<br />

5/L3 21<br />

A2 2/T1 4/T2 6/T3 14<br />

A2 2/T1 4/T2<br />

6/T3 22<br />

GMC-6M/4~16M/4, GMD-6M/4~16M/4<br />

4-Pole contactors<br />

A1 1/L1<br />

3/L2<br />

5/L3 7/L4<br />

A1 1/NO 3/NC 5/NC<br />

7/NO<br />

A2 2/T1<br />

4/T2<br />

6/T3 8/T4 A2 2/NO 4/NC 6/NC 8/NC<br />

32


Mini contactors with Solder pin type<br />

GMC-6MP<br />

GMC-9MP<br />

45<br />

57<br />

A1<br />

8.7<br />

On printed circuit board<br />

8.7 8.7 8.7 8.7 A1<br />

[mm]<br />

GMC-12MP<br />

GMC-16MP<br />

GMC-6MP/4<br />

GMC-9MP/4<br />

58<br />

50.7<br />

50.7<br />

GMC-12MP/4<br />

GMC-16MP/4<br />

4.4<br />

A2<br />

10x∅1.6<br />

45<br />

A2<br />

0.17kg<br />

GMD-6MP<br />

GMD-9MP<br />

45<br />

69<br />

A1<br />

8.7<br />

On printed circuit board<br />

8.7 8.7 8.7 8.7 A1<br />

GMD-12MP<br />

GMD-16MP<br />

GMD-6MP/4<br />

GMD-9MP/4<br />

58<br />

50.7<br />

50.7<br />

GMD-12MP/4<br />

GMD-16MP/4<br />

4.4<br />

A2<br />

10x∅1.6<br />

45<br />

A2<br />

0.23kg<br />

Circuit diagram<br />

GMC-6MP~16MP, GMD-6MP~16MP<br />

3-Pole contactors<br />

A1<br />

1/L1 3/L2 5/L3 13<br />

A1 1/L1<br />

3/L2<br />

5/L3 21<br />

A2 2/T1 4/T2 6/T3 14<br />

A2 2/T1 4/T2<br />

6/T3 22<br />

GMC-6MP/4~16MP/4, GMD-6MP/4~16MP/4<br />

4-Pole contactors<br />

A1 1/L1<br />

3/L2<br />

5/L3 7/L4<br />

A1 1/NO 3/NC 5/NC<br />

7/NO<br />

A2 2/T1<br />

4/T2<br />

6/T3 8/T4 A2 2/NO 4/NC 6/NC 8/NC<br />

33


Dimensions<br />

Mini contactors with Fast-on type<br />

GMC-6MF<br />

[mm]<br />

GMC-9MF<br />

GMC-12MF<br />

GMC-16MF<br />

GMC-6MF/4<br />

GMC-9MF/4<br />

GMC-12MF/4<br />

GMC-16MF/4<br />

0.18kg<br />

GMD-6MF<br />

GMD-9MF<br />

GMD-12MF<br />

GMD-16MF<br />

GMD-6MF/4<br />

GMD-9MF/4<br />

GMD-12MF/4<br />

GMD-16MF/4<br />

0.27kg<br />

Circuit diagram<br />

GMC-6MF~16MF, GMD-6MF~16MF<br />

GMC-6MF/4~16MF/4, GMD-6MF/4~16MF/4<br />

34


Mini contactors with Cage clamp type<br />

GMC-6MC<br />

GMC-9MC<br />

GMC-12MC<br />

2x0.75~1.5mm 2<br />

2xAWG18~14<br />

10<br />

57<br />

7<br />

4xM4(Mounting hole)<br />

37.7<br />

35<br />

[mm]<br />

GMC-16MC<br />

GMC-6MC/4<br />

GMC-9MC/4<br />

49<br />

61<br />

50<br />

GMC-12MC/4<br />

GMC-16MC/4<br />

45<br />

0.19kg<br />

GMD-6MC<br />

GMD-9MC<br />

GMD-12MC<br />

2x0.75~1.5mm 2<br />

2xAWG18~14<br />

10<br />

69<br />

7<br />

4xM4(Mounting hole)<br />

37.7<br />

35<br />

GMD-16MC<br />

GMD-6MC/4<br />

GMD-9MC/4<br />

49<br />

61<br />

50<br />

GMD-12MC/4<br />

GMD-16MC/4<br />

45<br />

0.28kg<br />

Circuit diagram<br />

GMC-6MC~16MC, GMD-6MC~16MC<br />

3-Pole contactors<br />

A1 1/L1<br />

3/L2<br />

5/L3 13 A1 1/L1 3/L2 5/L3 21<br />

A2 2/T1<br />

4/T2<br />

6/T3 14 A2 2/T1 4/T2 6/T3 22<br />

GMC-6MC/4~16MC/4, GMD-6MC/4~16MC/4<br />

4-Pole contactors<br />

A1 1/L1 3/L2 5/L3 7/L4 A1 1/NO 3/NC 5/NC 7/NO<br />

A2 2/T1 4/T2 6/T3 8/T4 A2 2/NO 4/NC 6/NC 8/NC<br />

35


Dimensions<br />

Mini contactors with Auxiliary contacts<br />

GMC-6M<br />

GMC-9M<br />

45<br />

36.1<br />

M3.5<br />

M3.5<br />

(Coil terminal)<br />

93.4<br />

81<br />

43.1<br />

37.7<br />

35<br />

4<br />

[mm]<br />

GMC-12M<br />

GMC-16M<br />

+<br />

AU-4M<br />

12<br />

33.5<br />

57<br />

50<br />

7.6<br />

17.4<br />

34.8<br />

0.21kg<br />

GMC-6M<br />

45<br />

M3.5<br />

M3.5<br />

(Coil terminal)<br />

58<br />

43.1<br />

37.7<br />

35<br />

GMC-9M<br />

GMC-12M<br />

GMC-16M<br />

+<br />

2× AU-1M<br />

33.5<br />

52<br />

57<br />

4<br />

50<br />

7.6<br />

17.4<br />

10.1 34.8<br />

65<br />

0.21kg<br />

GMC-6MP<br />

GMC-9MP<br />

65<br />

57<br />

4.4<br />

A1 8.7<br />

GMC-12MP<br />

GMC-16MP<br />

+<br />

2× AU-1MP<br />

58<br />

50.7<br />

A2<br />

10<br />

GMC-6MF<br />

GMC-9MF<br />

8.7 3.8<br />

Clip 1x6.35<br />

Clip 2x2.8<br />

93<br />

7<br />

37.7<br />

35<br />

GMC-12MF<br />

GMC-16MF<br />

+<br />

AU-4MF<br />

58<br />

50<br />

36 1.2<br />

45<br />

0.23kg<br />

36


Mini contactors with Auxiliary contacts<br />

GMC-6MF<br />

GMC-9MF<br />

65<br />

Clip 1x6.35<br />

Clip 2x2.8<br />

57<br />

7<br />

37.7<br />

35<br />

[mm]<br />

2×GMC-12MF<br />

GMC-16MF<br />

+<br />

AU-1MF<br />

58<br />

58<br />

8.7 3.8 1.2<br />

0.32kg<br />

GMC-6MC<br />

GMC-9MC<br />

2x0.75~1.5mm<br />

2xAWG18,16<br />

92.6<br />

57<br />

37.7<br />

35<br />

GMC-12MC<br />

GMC-16MC<br />

+<br />

AU-4MC<br />

15.9<br />

38<br />

49<br />

61<br />

50<br />

36<br />

45<br />

7<br />

0.24kg<br />

GMC-6MC<br />

2x0.75~1.5mm<br />

2xAWG18,16<br />

57<br />

37.7<br />

35<br />

GMC-9MC<br />

2×GMC-12MC<br />

GMC-16MC<br />

+<br />

AU-1MC<br />

49<br />

61<br />

50<br />

45<br />

65<br />

7<br />

0.23kg<br />

37


Dimensions<br />

Mini contactors with external accessories<br />

GMC-6M<br />

GMC-9M<br />

38<br />

45<br />

M3.5<br />

M3.5<br />

(Coil terminal)<br />

94.6<br />

58<br />

37.7<br />

35<br />

3.5<br />

27<br />

33.5<br />

57<br />

4<br />

[mm]<br />

GMC-12M<br />

GMC-16M<br />

+<br />

AT-12M<br />

50<br />

17.4<br />

34.8<br />

0.21kg<br />

GMD-6M<br />

GMD-9M<br />

45<br />

8.5<br />

M3.5<br />

M3.5<br />

(Coil terminal)<br />

80<br />

2.3 58<br />

37.7<br />

80<br />

GMD-12M<br />

GMD-16M<br />

+<br />

AS-12M<br />

27<br />

33.5<br />

57<br />

6<br />

50 4<br />

17.4<br />

34.8<br />

0.175kg<br />

38


Thermal overload relays for Mini contactors<br />

GTH(K)-12M<br />

45<br />

8.1<br />

ф1.6 8.8<br />

ф1.3<br />

43.1<br />

[mm]<br />

M3.5<br />

(Main terminal)<br />

10<br />

7.6<br />

55.5<br />

73.2<br />

M3.5<br />

(Main terminal)<br />

10.6 7.6<br />

1.9 20.4<br />

44.5<br />

63.7<br />

0.1kg<br />

GTH(K)-12MH<br />

45<br />

7.6<br />

8.7<br />

70.7<br />

49.8<br />

35<br />

4-M4<br />

(Mounting hole)<br />

M3.5<br />

(Main terminal)<br />

M3.5<br />

(Aux. terminal)<br />

10<br />

7.6<br />

55.5<br />

89<br />

81<br />

M3.5<br />

(Main terminal)<br />

10.6<br />

7.6<br />

7<br />

1.9<br />

27.4<br />

7<br />

51.5<br />

0.4kg<br />

39


Dimensions<br />

Mini motor starters, open<br />

GMS-6M<br />

GMS-9M<br />

GMS-12M<br />

M3.5<br />

(Main terminal)<br />

45<br />

7.6 8.7<br />

57<br />

43.1<br />

37.7<br />

35<br />

4-M4<br />

(Mounting hole)<br />

[mm]<br />

GMS-16M<br />

50<br />

M3.5<br />

(Main terminal)<br />

116.1<br />

M3.5<br />

(Aux. terminal)<br />

10<br />

7.6<br />

55.5<br />

M3.5<br />

(Main terminal)<br />

10.6<br />

7.6<br />

1.9<br />

44.5<br />

63.7<br />

20.4<br />

0.26kg<br />

GMS-6MD<br />

GMS-9MD<br />

GMS-12MD<br />

GMS-16MD<br />

M3.5<br />

(Main terminal)<br />

45<br />

7.6 8.7<br />

69<br />

48.1 37.7<br />

4-M4<br />

35<br />

(Mounting hole)<br />

50<br />

M3.5<br />

(Main terminal)<br />

116.1<br />

M3.5<br />

(Aux. terminal)<br />

10<br />

55.5<br />

7.6<br />

M3.5<br />

(Main terminal)<br />

10.6 7.6<br />

1.9<br />

44.5<br />

63.7<br />

20.4<br />

0.39kg<br />

40


Mini contactor relays<br />

GMR-4M<br />

45<br />

M3.5<br />

M3.5<br />

(Coil terminal)<br />

57<br />

43.3<br />

4XM4(Mounting hole)<br />

37.7<br />

35<br />

[mm]<br />

33.5<br />

58<br />

50<br />

4<br />

7.6 8.7<br />

7<br />

0.17kg<br />

GMR-4MD<br />

45<br />

M3.5<br />

M3.5<br />

(Coil terminal)<br />

69<br />

55.3<br />

4XM4(Mounting hole)<br />

37.7<br />

35<br />

33.5<br />

58<br />

50<br />

4<br />

7.6<br />

8.7<br />

7<br />

0.23kg<br />

GMR-4M<br />

GMR-8M<br />

45<br />

36.1<br />

M3.5<br />

M3.5<br />

(Coil terminal)<br />

93.4<br />

81<br />

4XM4(Mounting hole)<br />

37.7<br />

35<br />

12<br />

33.5<br />

57<br />

50<br />

4<br />

7.6<br />

17.4<br />

34.8<br />

43.1<br />

0.21kg<br />

GMR-4M<br />

GMR-8M<br />

45<br />

36.1<br />

M3.5<br />

M3.5<br />

(Coil terminal)<br />

103.7<br />

91.8<br />

4XM4(Mounting hole)<br />

37.7<br />

35<br />

12<br />

33.5<br />

57<br />

50<br />

4<br />

7.6<br />

17.4<br />

34.8<br />

55.3<br />

0.21kg<br />

GMR-4M<br />

+<br />

2× AU-1M<br />

45<br />

M3.5<br />

M3.5<br />

(Coil terminal)<br />

58<br />

43.1<br />

4XM4(Mounting hole)<br />

37.7<br />

35<br />

4<br />

33.5<br />

52<br />

57<br />

50<br />

7.6<br />

10.1<br />

17.4<br />

34.8<br />

65<br />

7<br />

0.21kg<br />

41


Dimensions<br />

Mini contactor relays<br />

GMR-4MP<br />

A1<br />

45 57 8.7<br />

On printed circuit board<br />

8.7 8.7 8.7 8.7<br />

A1<br />

[mm]<br />

58<br />

50.7<br />

50.7<br />

4.4<br />

A2<br />

10X<br />

(PCB hole)<br />

45<br />

A2<br />

0.19kg<br />

GMR-4MPD<br />

45<br />

69<br />

4.4<br />

A1<br />

8.7<br />

On printed circuit board<br />

8.7 8.7 8.7 8.7<br />

A1<br />

58<br />

50.7<br />

50.7<br />

A2<br />

10X<br />

(PCB hole)<br />

45<br />

A2<br />

0.28kg<br />

GMR-4MP<br />

+<br />

2× AU-1M<br />

65<br />

57<br />

45 8.7 8.7 8.7 8.7<br />

4.4<br />

58<br />

50.7<br />

10.1 10.1<br />

42


Mini contactor relays<br />

GMR-4MF<br />

[mm]<br />

45<br />

Clip 1x6.35<br />

Clip 2x2.8<br />

57<br />

7<br />

37.7<br />

35<br />

0.18kg<br />

GMR-4MFD<br />

45<br />

69<br />

7<br />

1.2<br />

0.27kg<br />

GMR-6MF<br />

GMR-8MF<br />

Clip 1x6.35<br />

Clip 2x2.8<br />

93<br />

57<br />

8.7 3.8<br />

7<br />

37.7<br />

35<br />

1.2<br />

0.23kg<br />

65 Clip 1x6.35<br />

57<br />

37<br />

45<br />

Clip 2x2.8<br />

7<br />

35<br />

58<br />

58<br />

58<br />

50<br />

58<br />

50<br />

50<br />

58<br />

8.7 3.8<br />

1.2<br />

4xM4(Mounting hole)<br />

Clip 1x6.35<br />

Clip 2x2.8<br />

37.7<br />

35<br />

8.7<br />

3.8<br />

4xM4(Mounting hole)<br />

36<br />

45<br />

4xM4(Mounting hole)<br />

GMR-4MF<br />

+<br />

2× AU-1MF<br />

8.7<br />

3.8<br />

1.2<br />

4xM4(Mounting hole)<br />

0.32kg<br />

43


Dimensions<br />

GMR-4MC<br />

2x0.75~1.5mm 2<br />

2xAWG18,16<br />

10<br />

57<br />

4XM4(Mounting hole)<br />

37.7<br />

35<br />

[mm]<br />

45<br />

2x0.75~1.5mm 2<br />

2xAWG18,16<br />

10<br />

69<br />

7<br />

4XM4(Mounting hole)<br />

37.7<br />

35<br />

45<br />

2x0.75~1.5mm 2<br />

2xAWG18,16<br />

10<br />

57<br />

7<br />

4XM4(Mounting hole)<br />

37.7<br />

35<br />

2x0.75~1.5mm 2<br />

2xAWG18,16<br />

10<br />

57<br />

7<br />

4XM4(Mounting hole)<br />

37.7<br />

35<br />

49<br />

61<br />

50<br />

15.9<br />

38<br />

49<br />

61<br />

50<br />

49<br />

61<br />

50<br />

49<br />

61<br />

50<br />

7<br />

0.18kg<br />

GMR-4MCD<br />

0.27kg<br />

GMR-6MC<br />

GMR-8MC<br />

36<br />

45<br />

92.6<br />

0.23kg<br />

2×<br />

GMR-4MC<br />

+<br />

AU-1MC<br />

44<br />

45<br />

65<br />

0.32kg


2-pole DC <strong>Contactor</strong>s<br />

[mm]<br />

SMM-30P<br />

SMM-30DP<br />

0.61(0.93)kg<br />

SMM-60P<br />

SMM-100P<br />

SMM-60DP<br />

SMM-100DP<br />

1.15(2.17)kg<br />

45


Dimensions<br />

2-pole AC <strong>Contactor</strong>s<br />

GMC-10P2<br />

[mm]<br />

GMC-20P2<br />

GMC-25P2<br />

GMC-30P2<br />

GMC-35P2<br />

GMC-40P2<br />

(TSBS Type)<br />

1.29kg<br />

GMC-10P2<br />

GMC-20P2<br />

GMC-25P2<br />

GMC-30P2<br />

GMC-35P2<br />

GMC-40P2<br />

(TQBS Type)<br />

87.6<br />

1.29kg<br />

Circuit diagram<br />

GMC-10P2~40P2<br />

Terminal<br />

Type<br />

Terminal<br />

Screw Wire Torque<br />

(mm²) (kgf∙cm) (mm)<br />

A×B×C<br />

C<br />

B<br />

GMC-10P2~40P2<br />

Main M5 1-16 26 12.2×7×8<br />

Coil M3.5 1-2.5 12 7.7×7.5×4.5<br />

A<br />

46


47<br />

Accessories for Mini contactors<br />

36.1<br />

8.7<br />

7.6<br />

M3.5<br />

12<br />

32<br />

35.4<br />

38.8<br />

AU-4M<br />

35.4<br />

38.8<br />

26.1<br />

36.1<br />

M3.5<br />

7.6<br />

12<br />

32<br />

AU-2M<br />

10<br />

7.6<br />

41<br />

33.5<br />

52<br />

M3.5<br />

1.3<br />

53.9<br />

44.5<br />

51.7<br />

AU-1M<br />

0.04kg<br />

0.03kg<br />

0.02kg<br />

38<br />

27<br />

40.2<br />

36<br />

AT-12M<br />

8<br />

26<br />

22<br />

47.3<br />

16.9<br />

22.1<br />

3.5<br />

AS-12M<br />

0.04kg<br />

0.005kg<br />

[mm]


Safety Instructions<br />

For your safety, please read user's manual thoroughly before operating.<br />

Contact the nearest authorized service facility for examination, repair, or adjustment.<br />

Please contact a qualified service technician when you need maintenance.<br />

Do not disassemble or repair by yourself!<br />

Any maintenance and inspection shall be performed by the personnel having expertise concerned.<br />

c 2012.10 <strong>LSIS</strong> Co.,Ltd. All rights reserved.<br />

www.lsis.biz<br />

HEAD OFFICE<br />

Korea Gyeonggi-do Anyang-si dongan-gu<br />

LS-ro 127 (Hogye-dong)<br />

Tel. (82-2)2034-4887, 4873, 4148<br />

Fax. (82-2)2034-4648<br />

CHEONG-JU PLANT<br />

Cheong-Ju Plant #1, Song Jung Dong, Hung Duk Ku,<br />

Cheong Ju, 361-720, Korea<br />

Specifications in this catalog are subject to change without notice due to<br />

continuous product development and improvement.<br />

Global Network<br />

<strong>LSIS</strong> (Middle East) FZE Dubai, U.A.E.<br />

Address: LOB 19 JAFZA VIEW TOWER Room 205, Jebel Ali Freezone P.O. Box 114216, Dubai, United Arab Emirates<br />

Tel: 971-4-886 5360 Fax: 971-4-886-5361 e-mail: dhleef@lsis.biz<br />

Dalian <strong>LSIS</strong> Co., Ltd. Dalian, China<br />

Address: No.15, Liaohexi 3-Road, Economic and Technical Development zone, Dalian 116600, China<br />

Tel: 86-411-8273-7777 Fax: 86-411-8730-7560 e-mail: tangyh@lsis.com.cn<br />

<strong>LSIS</strong> (Wuxi) Co., Ltd. Wuxi, China<br />

Address: 102-A , National High & New Tech Industrial Development Area, Wuxi, Jiangsu, 214028, P.R.China<br />

Tel: 86-510-8534-6666 Fax: 86-510-522-4078 e-mail: luw@lsis.com.cn<br />

<strong>LSIS</strong>-VINA Co., Ltd. Hanoi, Vietnam<br />

Address: Nguyen Khe - Dong Anh - Ha Noi - Viet Nam<br />

Tel: 84-4-882-0222 Fax: 84-4-882-0220 e-mail: sjbaik@lsis.biz<br />

<strong>LSIS</strong>-VINA Co., Ltd. Hochiminh , Vietnam<br />

Address: 41 Nguyen Thi Minh Khai Str. Yoco Bldg 4th Floor, Hochiminh City, Vietnam<br />

Tel: 84-8-3822-7941 Fax: 84-8-3822-7942 e-mail: hjchoid@lsis.biz<br />

<strong>LSIS</strong> Shanghai Office Shanghai, China<br />

Address: Room 32 floors of the Great Wall Building, No. 3000 North Zhongshan Road, Putuo District, Shanghai, China<br />

Tel: 86-21-5237-9977 Fax: 89-21-5237-7189 e-mail: baijh@lsis.com.cn<br />

<strong>LSIS</strong> Beijing Office Beijing, China<br />

Address: B-Tower 17FL.Beijing Global Trade Center B/D. No.36, BeiSanHuanDong-Lu, DongCheng-District,<br />

Beijing 100013, P.R. China<br />

Tel: 86-10-5825-6025,7 Fax: 86-10-5825-6026 e-mail: sunmj@lsis.com.cn<br />

<strong>LSIS</strong> Guangzhou Office Guangzhou, China<br />

Address: Room 1403, 14/F, New Poly Tower, No.2 Zhongshan Liu Road, Guangzhou 510180, P.R. China<br />

Tel: 020-8326-6754 Fax: 020-8326-6287 e-mail: chenxs@lsis.com.cn<br />

<strong>LSIS</strong> Chengdu Office Chengdu, China<br />

Address: Room 1701 17Floor, huamin hanjun internationnal Building, No1 Fuxing Road Chengdu, 610016, P.R. China<br />

Tel: 86-28-8670-3201 Fax: 86-28-8670-3203 e-mail: yangcf@lsis.com.cn<br />

<strong>LSIS</strong> Qingdao Office Qingdao, China<br />

Address: Room 2001,20/F,7B40, Galaxy Building, No.29 Shandong Road, Shinan District, Qingdao 266071, P.R. China<br />

Tel: 86-532-8501-6058 Fax: 86-532-8501-6057 e-mail: wangzy@lsis.com.cn<br />

<strong>LSIS</strong> NETHERLANDS Co.Ltd Schiphol-Rijk, Netherlands<br />

Address: 1st. Floor, Tupolevlaan 48, 1119NZ,Schiphol-Rijk, The Netherlands<br />

Tel: 31-20-654-1420 Fax: 31-20-654-1429 e-mail: junshickp@lsis.biz<br />

<strong>LSIS</strong> Gurgaon Office Gurgaon ,India<br />

Address: 109 First Floor, Park Central, Sector-30, Gurgaon- 122 002, Haryana, India e-mail: hwyim@lsis.biz<br />

2013. 05 Mini <strong>Contactor</strong>s and <strong>Overload</strong> Relays (E) 2012. 10 / (02) 2013. 05 Printed in Korea STAFF


www.lsis.com<br />

www.lsis.biz<br />

Meta Solution<br />

Electronic motor protection relays


<strong>EMPR</strong><br />

replacing thermal overload relay is electronic motor protection relay which is used<br />

to protect the low voltage motor and also called as Electronic Overcurrent Relay or an Electronic<br />

<strong>Overload</strong> Relay.<br />

As a digital motor protection relay with MCU, <strong>EMPR</strong> is highly reliable by implementation of realtime<br />

data processing and high precision and also can secure motor safely with various functions<br />

such as phase loss, phase reverse, unbalanced, stall, lock, ground fault, short circuit protection<br />

depending on the model .<br />

<strong>EMPR</strong> has compact and simple appearance so it can be combined with the magnetic contactor.<br />

Various installation methods and separation of terminal block make easy design and<br />

manufacturing feature for MCC(Motor Control Center).<br />

Especially, <strong>EMPR</strong> is EMC tested and approved to operate safely without any malfunction caused<br />

by electromagnetic wave and surge. Most of the models have received CE Mark and UL<br />

certification based on its product reliability.<br />

Contents<br />

Features 4<br />

Ordering 7<br />

Specification 8<br />

Characteristics 12<br />

Setting method 21<br />

Dimensions 30<br />

Wiring method 36<br />

Accessories 39<br />

<strong>EMPR</strong> Curves 41<br />

Direct mounting <strong>EMPR</strong> new/old 42<br />

comparative table<br />

Certificates 43


General Motor Protection Relay<br />

GMP Series<br />

Various connection & mount<br />

Inverse or definite time protection mode<br />

Ground fault type<br />

Display the causes of the falut by LED<br />

Digital Motor Protection Relay<br />

DMP Series<br />

Ampere meter, Load rate and the causes of fault Display<br />

Standard, Ground fault and short circuit protection type<br />

Select the Inverse or definite time protection mode<br />

Unit or Extension in one body by cable option<br />

Option function type (DMP-a)<br />

Intelligent Motor Protection Relay<br />

IMP Series<br />

Wide current setting range (0.125~100A)<br />

Communication support type (MODBUS. Analog)<br />

Zero current and residual current sensing<br />

Save the fault events and operating time setup<br />

Select the Inverse, thermal inverse or definite time modes<br />

Unit or Extension in one body by option cable


Electronic motor protection relays<br />

Features<br />

GMP Series<br />

● Combination with Metasol contactors for compact motor starters<br />

<strong>EMPR</strong> model<br />

GMP22-2P/3P/3PR<br />

GMP40-2P/3P/3PR<br />

<strong>Contactor</strong> model<br />

MC-9b, MC-12b, MC-18b, MC-22b<br />

MC-32a, MC-40a<br />

● Broad range of current setting<br />

● Inverse time or definite time characteristics<br />

● Simple operation and trip cause indication via LED<br />

● Various Connection<br />

Current<br />

setting<br />

Test /<br />

Reset button<br />

Direct mount<br />

on a contactor<br />

Screw connection &<br />

Separate mount<br />

Passing through CT holes &<br />

Separate mount<br />

LED indicator<br />

Trip time setting<br />

Certification of CE, UL, CCC and S mark<br />

● Various protection functions<br />

Types (GMP-) 2P, 2T, 2S 3P, 3T, 3S 3PR, 3TR, 3SR 3TN, 3TZ 3TNR, 3TZR<br />

Number of sensors 2CT 3CT<br />

Overcurrent <br />

Phase failure <br />

Lock/Stall <br />

Phase unbalance <br />

Reverse phase <br />

Ground fault <br />

● Large current can be applied through additional current transformers<br />

● MCU (Microprocessor Control Unit) built-in<br />

- excellent reliability by achieving real-time data processing and high precision.<br />

● Checking the last failure cause<br />

- can be checked by pushing Test/Reset button twice in 0.5 seconds,<br />

● Products for ground fault protection<br />

- detecting of zero phase currents (ZCT used: GMP60-3TZ)<br />

- detecting of residual currents (ZCT unused: GMP60-3TN)<br />

4


Features<br />

DMP Series<br />

● Digital measuring and displaying<br />

- Display digital ampere-meter<br />

- Save the causes of the fault and the value<br />

- Display motor load rate by graph<br />

R phase<br />

S phase<br />

T phase<br />

Test/Reset button<br />

FUNC button<br />

Digital display<br />

Bar graph<br />

Display button<br />

Sel button<br />

Current knob<br />

Time knob<br />

R<br />

S<br />

T<br />

R<br />

S<br />

T<br />

R<br />

S<br />

T<br />

R phase current value S phase current value T phase current value<br />

● Convenient structure<br />

- Install the Unit / Extension type in one body<br />

The display part may be separated from the body<br />

You can check the values and the causes of the<br />

fault without opening the distribution panel door<br />

- removable terminal block<br />

● Various protection functions<br />

Protection DMP-S/Sa DMP-SZ/SZa DMP-SI DMP-T/Ta DMP-TZ/TZa DMP-TI<br />

Wiring Screw type Tunnel type<br />

Over current <br />

Under current <br />

Stall <br />

Lock <br />

Phase failure <br />

Reverse phase <br />

Phase unbalance <br />

Ground fault <br />

Short circuit <br />

● Trip curve selectable (Inverse/Definite)<br />

● Applicable to inverter control circuit<br />

LS <strong>EMPR</strong> has high performance under the harmonic noise and can be<br />

used in the Inverter control circuit (20~200Hz), (except Ground fault<br />

model)<br />

● Optional functions (DMP-a type)<br />

- Storing up the last fault cause<br />

- Storing up motor operation hours<br />

- Checking replacement cycle of motor bearing by alarming<br />

Inverse time characteristics<br />

Definite time characteristics<br />

5


Electronic motor protection relays<br />

Features<br />

IMP Series<br />

The <strong>EMPR</strong> IMP series are optimal solutions for protecting and monitoring motors in<br />

complex industrial fields needed high safety and productivity.<br />

~100A<br />

Wide Current Setting Range:<br />

0.125~100A for One Model<br />

With the slide S/W, the current setting range<br />

MCU<br />

Comprehensive Digital Motor Protection<br />

Relay with the MCU (Microprocessor<br />

Control Unit)<br />

can be decided 0.5~10A or 5~100A.<br />

Real-time processing and high precision<br />

Depending on the number of CT penetration,<br />

even 0.125A current can be protected. (Wire<br />

penetration hole is required).<br />

One-Body Type and Separate Body Type<br />

The display can be attached to the panel front so<br />

that current, operation time and settings can be<br />

Communication support type<br />

checked without fetching the unit. With the display<br />

RS-485 MODBUS communication with various<br />

separated, the motor protection is available.<br />

systems.The model with analogue signals<br />

(4~20mA) is compatible with transducer<br />

systems.<br />

Thermal Inverse Time,<br />

Inverse Time and Definite Time Modes<br />

INV<br />

Applicable to Inverter Circuits<br />

Thanks to its characteristics to harmonic noise,<br />

it can be applied to the inverter control circuits.<br />

The available frequency range is 20~200Hz.<br />

When the relative harmonic factor is over 30%,<br />

According to user’s needs, the motor can be<br />

a harmonic filter should be installed (However,<br />

protected in the inverse time mode or definite<br />

the ground fault function should be off).<br />

time mode.<br />

Various Reset Functions<br />

30mA<br />

25A<br />

Wide Setting of Ground Fault Current<br />

Sensitivity 30mA~25A<br />

Return<br />

Manual, automatic and electric reset functions<br />

are provided for customer convenience.<br />

zero current sensing by zero sequence CT.<br />

zero current sensing by Residual circuit.<br />

Password<br />

Settings are protected with a password.<br />

Date and Total Operating Time Setup<br />

March<br />

May<br />

July<br />

When a fault occurs, its date and time are<br />

stored for easy checkup. When the total<br />

operation time is over, it is displayed for<br />

changing motor bearings or supplying oil.<br />

Save<br />

Storage of Fault Events<br />

Up to 5 fault events can be stored for easy<br />

fault history management.<br />

Quick Setup<br />

All settings can be decided quickly on the<br />

display.<br />

3-Phase Digital Ampere-Meter<br />

3-phase current is displayed every two<br />

seconds for motor monitoring.<br />

6


Ordering<br />

GMP Series<br />

GMP 22<br />

2 P R a 1.5A 220 1a1b Sol<br />

Frame Nominal Current Type<br />

1.5A<br />

Direct<br />

22 5A<br />

22A<br />

Coupling,<br />

Terminal<br />

40<br />

20A<br />

40A<br />

Connection,<br />

Penetration<br />

80 80A Terminal Connection<br />

06A<br />

60 30A Penetration<br />

60A<br />

CT Type<br />

2 2CT<br />

3 3CT<br />

P<br />

S<br />

T<br />

TE<br />

PD<br />

Type<br />

Direct Coupling(Pin)<br />

Terminal<br />

Connection(Screw)<br />

Penetration<br />

(Tunnel)<br />

Economic<br />

Direct Coupling<br />

(Definite Time)<br />

Reverse Phase<br />

-<br />

R<br />

A<br />

No Reverse<br />

Protection<br />

Reverse Protection<br />

Protection Available<br />

Automatic<br />

Recovery<br />

Control Voltage<br />

Nominal Current Current Adjustment Range (A)<br />

60A 0.5~60 Note) AC 380(440)V and<br />

AC 480V are for<br />

1.5A 0.3~1.5 110/220 AC 100~260V<br />

5A 1~5<br />

24 AC 24V<br />

22A 4.4~22<br />

48 AC 48V<br />

20A 4~20<br />

110 AC 110V<br />

40A 8~40<br />

220 AC 220V<br />

80A 16~80<br />

380 AC 380 (440)V<br />

06A 0.5~6<br />

480 AC 180~480V<br />

30A 3~30<br />

Note) AC 24V, AC 48V,<br />

GMP60T.<br />

Note) For GMP60-TD, GMP60-TDa 6/60A,<br />

GMP60-3TZ (R), 3TN (R), 3T (R)<br />

Aux. contactor<br />

1c (N)<br />

1a1b<br />

Note) When the<br />

power is<br />

applied, the<br />

system is in<br />

the contacting<br />

status.<br />

1c (R) type is<br />

optional<br />

Model Type<br />

Terminal<br />

(Screw)<br />

- Penetration<br />

(Tunnel)<br />

Sol<br />

Metasol<br />

Direct<br />

Coupling<br />

(Pin)<br />

TD<br />

TZ<br />

TN<br />

Current Display<br />

(Definite Time)<br />

Ground Fault Protection<br />

(Zero-Phase- Sequence<br />

Current Detection)<br />

Ground Fault Protection<br />

(Residual Current<br />

Detection)<br />

Classification<br />

- Existing Model<br />

Operation Time<br />

a<br />

Function<br />

DMP Series<br />

DMP 06 S Z a 220 1a1b<br />

Current Adjustment Range<br />

06 0.5~6A<br />

36 3~36A<br />

60 5~60A<br />

S<br />

T<br />

Wiring<br />

Terminal<br />

(Screw)<br />

Penetration<br />

(Tunnel)<br />

OPTION<br />

- Standard Model<br />

Ground Fault<br />

Z<br />

Protection<br />

I<br />

Short circuit<br />

Protection<br />

Classification<br />

- Existing Model<br />

a<br />

Operation Time<br />

Function<br />

Control Voltage<br />

220 AC 220V<br />

110 AC 110V<br />

Aux. contactor<br />

1a1b<br />

2a<br />

2b<br />

2a1b<br />

Note) 1. Even the same model has different contact specifications.<br />

2. When the power is applied, the system is in the contacting status.<br />

IMP Series<br />

IMP<br />

C<br />

A420<br />

110/220<br />

Factors Protected<br />

Communication<br />

Control Voltage<br />

C<br />

Current<br />

NO<br />

None<br />

110/220 AC/DC 85~245V<br />

A420<br />

4~20mA Output<br />

24/36 AC/DC 24~36V<br />

M485<br />

MODBUS/RS-485<br />

7


Electronic motor protection relays<br />

Specification<br />

GMP Series<br />

Ratings<br />

Model<br />

GMP22-2P/PD (1c)<br />

Note) 1. When it is 2CT modle, only two-phase protection is available<br />

2. The bracket for Din-rail mount is optional<br />

3. 1c(N): No volt release contact type [1c(R), Non-fail-safe operation contact type is optinal]<br />

GMP22-<br />

2P(1a1b)<br />

GMP22-<br />

3P/3PR<br />

GMP22-2S<br />

GMP22-<br />

3S/3SR<br />

GMP22-2T<br />

Type Pin type Screw type Tunnel type<br />

No. of CT 2CT 2CT 3CT 2CT 3CT 2CT 3CT<br />

Protection Overcurrent ● ● ● ● ● ● ●<br />

Phase failure Note1) ● ● ● ● ● ● ●<br />

Lock/Stall ● ● ● ● ● ● ●<br />

Phase unbalance — — ● — ● — ●<br />

Reverse phase — — ●(3PR) — ●(3SR) — ●(3TR)<br />

Current setting range (A) 0.3~1.5, 1~5, 4.4~22<br />

Operating time characteristics<br />

Time setting Inverse time 0~30 sec<br />

Inverse time (GMP22-2PD: Definite time)<br />

(sec) Definite D-time 0.2~60 sec for GMP22-2PD<br />

Reset-time<br />

O-time<br />

Tolerance Current ±5%<br />

Time<br />

5sec (Fixed) for GMP22-2PD<br />

Manual reset<br />

±5%(or±0.5sec)<br />

Control power Voltage AC 110V/220V(±10%) AC 100~260V<br />

Frequency<br />

50/60Hz<br />

Aux. contact Contact 1SPDT: 1c (N) Note 3) 2SPST (1a1b)<br />

Insulation resistance<br />

Surge endurance (IEC 61000-4-5)<br />

Fast transient burst (IEC 61000-4-4)<br />

Ratings 5A/250VAC Resistive load 3A/250VAC Resistive load<br />

Operate (95 96 Close) (95 96 Close) (97 98 Open)<br />

Min 100MΩ at 500Vdc<br />

5kV Apply the standard wave<br />

2kV<br />

Environment Operation -25~70℃<br />

Temperature Storage -30~80℃<br />

Relative humidity<br />

30~90%RH(No freezing)<br />

GMP22-<br />

3T/3TR<br />

Trip indicator Red LED Red/Green LED Red LED Red/Green LED Red LED Red/Green LED<br />

Dimension (mm) W×H×D 44×71×78 53×78×87.5 53×68×87.5 53×38×87.5<br />

Mounting type Direct mount onto a Metasol MC (MC-9b-22b) Separate mount (Screw or Din-rail) Note2)<br />

Certification<br />

UL, cUL, CE (Except GMP22-2PD type)<br />

8


Specification<br />

GMP Series<br />

Ratings<br />

Model<br />

GMP40-<br />

2P/PD/PA<br />

GMP40-<br />

3P/3PR<br />

GMP40-2S<br />

GMP40-<br />

3S/3SR<br />

GMP40-2T<br />

GMP40-<br />

3T/3TR<br />

GMP80-<br />

2S/SA<br />

Type Pin type * Screw type Tunnel type Screw type<br />

No. of CT 2CT 3CT 2CT 3CT 2CT 3CT 2CT 3CT<br />

Protection Overcurrent ● ● ● ● ● ● ● ●<br />

Phase failure Note1) ● ● ● ● ● ● ● ●<br />

Lock/Stall ● ● ● ● ● ● ● ●<br />

Phase unbalance — ● — ● — ● — ●<br />

Reverse phase — ●(3PR) — ●(3SR) — ●(3TR) — ●(3SR)<br />

Current setting range(A) 4~20, 8~40 16~80<br />

Operating time characteristics<br />

Time setting Inverse time 0~30 sec<br />

Inverse time characteristics<br />

(sec) Definite D-time 0.2~60 sec (GMP40-2PD)<br />

Reset time<br />

O-time<br />

Tolerance Current ±5%<br />

Time<br />

5sec (Fixed) (GMP40-2PD)<br />

Manual reset (Auto Reset type : GMP□-A)<br />

±5% (or±0.5 sec)<br />

Control power Voltage AC 100~260V, 50/60Hz<br />

Aux. contact Contact Note2) 2SPST (1a1b)<br />

Insulation resistance<br />

Ratings<br />

Surge endurance (IEC 61000-4-5)<br />

Fast transient burst (IEC 61000-4-4)<br />

3A/250VAC Resistive load<br />

Operate (95 96 Close) (97 98 Open)<br />

Min 100MΩ at 500Vdc<br />

5kV Apply the standard wave<br />

2kV<br />

Environment Operation -25~70℃<br />

Temperature Storage -30~80℃<br />

Relative humidity<br />

30~90%RH (No freezing)<br />

GMP80-<br />

3S/3SR<br />

Trip indicator Red LED Red/Green LED Red LED Red/Green LED Red LED Red/Green LED Red LED 2Red LEDs<br />

Dimension(mm) W×H×D 53×78×87.5 53×68×87.5 53×38×87.5 89×77.5×97.4<br />

Mounting type<br />

Direct mount onto a<br />

Metasol MC (MC-32a, 40a)<br />

Separate mount (Screw or Din-rail)<br />

Certification<br />

UL, cUL, CE (Except GMP-PD, PA, SA type)<br />

Note) 1. When it is 2CT modle, only two-phase protection is available<br />

2. When power applied Aux. Contact operate<br />

9


Electronic motor protection relays<br />

Specification<br />

GMP Series<br />

Ratings<br />

Model<br />

GMP60T<br />

GMP60-TE GMP60-TD GMP60-TDa GMP60-3T(R)<br />

GMP60-3TZ(R)<br />

GMP60-3TN(R)<br />

Type Tunnel type Tunnel type Tunnel type Tunnel type<br />

No. of CT 2CT 2CT 3CT 3CT<br />

Protection Overcurrent ● ● ● ●<br />

Phase failure ● ● ● ●<br />

Lock/Stall ● ● ● ●<br />

Phase unbalance — — ● ●<br />

Reverse phase — — ●(R Type) ●(R Type)<br />

Ground fault Note1) — — — ●<br />

Current setting range (A) 0.5~6, 3~30, 5~60 0.5~60 0.5~60 0.5~60<br />

Operating time characteristics Definite Definite Definite Definite<br />

Time setting D time 0.2~30 sec 1~60 sec 0.2~60 sec 0.2~60 sec<br />

(sec) O time 0.2~15 sec 5 sec (Fixed) 0.5~30 sec 0.2~15 sec 3 sec (Fixed)<br />

Tolerance<br />

A time (Reset) — 0.2~120 Note4) — 1~20 min — —<br />

Current ±5% Time ±5% (or±5 sec)<br />

Control power Voltage Note3) AC 110V/220 (±10%) Note3) AC 110V or 220V (±10%) AC 100V~260V<br />

Frequency<br />

50/60Hz<br />

Aux. contact Contact 1SPDT: 1c (N) Note 2) 2SPST (1a1b)<br />

Insulation resistance<br />

Surge endurance (IEC 61000-4-5)<br />

Fast transient burst (IEC 61000-4-4)<br />

Ratings 1A/250VAC Resistive load 3A/250VAC Resistive load<br />

Min 100MΩ at 500Vdc<br />

5kV Apply the standard wave<br />

2kV<br />

Environment Operation -25~70℃<br />

Temperature Storage -30~80℃<br />

Relative humidity<br />

30~90% RH (No freezing)<br />

Trip indicator Red LED 7 Segment Red/Green×2-Color LED Red/Green×2-Color LED, Red LED<br />

Dimension(mm) W×H×D 72×67×69 75×72.8×47 94.6×95×97 94.6×95×97<br />

Mounting type<br />

Separate mount (Screw or Din-rail)<br />

Certification UL, cUL, CE —<br />

Note) 1. 3TZ(R): Zero sequence CT type, 3TN(R): Residual curcuit<br />

2. 1c(N): No volt release contact type [1c(R), Non-fail-safe operation contact type is optinal]<br />

3. GMP60T/TE: AC 24V, 48V, 380V or 480V 50/60Hz types a option<br />

4. GMP60TA: Auto Reset type<br />

10


Specification<br />

DMP/IMP Series<br />

Ratings<br />

Model<br />

DMP-S/SZ/SI DMP-Sa/SZa DMP-T/TZ/TI DMP-Ta/TZa IMP-C-NO IMP-C-A420 IMP-C-M485<br />

Wiring Screw type Tunnel type Tunnel type<br />

Panel mount Unit or Extension Note1) Unit or Extension<br />

Operation time Inverse/Definite Thermal Inverse/Inverse/Definite<br />

Protection Over current According to the setting time According to the setting time<br />

Phase failure 3 sec 1.5 sec<br />

Reverse phase Within 0.1 sec Within 0.1 sec<br />

Lock/Stall Within 0.5 sec Within 0.5 sec<br />

Phase unbalance 5 sec 3 sec<br />

Under current 3 sec 3 sec<br />

Ground fault Within 0.05~1 sec. (DMP-Z/Za) Within 0.05~1 sec Note2)<br />

Short circuit Within 50ms (DMP-I) Within 50ms<br />

Alarm Variable (60~110% of the setting current) Variable (60~110% of the setting current)<br />

Current setting range (A) 6: 0.5~6A, 36 : 3~36A, 60: 5~60A 0.5~100<br />

Time setting Definite D time 0~60 sec 1~200 sec<br />

(sec) O time 0~30 sec 1~60 sec<br />

Inverse time 0~60 sec 1~60 sec<br />

A time (Reset) Manual reset Manual reset/Autometic<br />

Tolerance Current ±5% ±5%<br />

Time ±5% (or±0.5 sec) ±5% (or±0.5 sec)<br />

Operating power Voltage AC 110V or 220V(±10%), 50/60Hz AC/DC 85~245V, AC/DC 24~36V (50/60Hz)<br />

Aux. contact 2a, 2b, 1a1b OL: 1a1b, AL: 1a<br />

Insulation resistance Over DC 500V 100MΩ Over DC 500V 100MΩ<br />

Surge impulse voltage (IEC 61000-4-5) 5kV 5kV<br />

Fast transient burst (IEC 61000-4-4) 2kV 2kV<br />

Environment Operation -25~70℃ -25~70℃<br />

Temperature Storage -30~80℃ -30~80℃<br />

Relative humidity 30~90% RH (No freezing) 30~90% RH (No freezing)<br />

Display 7-Segment Cause of a fault Ampere meter 3 phase current, cause of a fault<br />

Bar-Graph 60~110% of real load current 60~110% of real load current<br />

Mounting type 35mm Din-rail/Panel 35mm Din-rail/Panel<br />

Certification UL, cUL, CE (Except DMP36 type) CE<br />

Note) 1. In extension type, the digital <strong>EMPR</strong> is calibrated with combining the display past and main body so, please cautious not to combine the display part and main body with different part No.<br />

2. Zero current sensing by zero sequencee CT and Residual circuit.<br />

3. DMP-a Type option : Operating time, Fault event save, 3phase current Ampere meter Function<br />

11


Electronic motor protection relays<br />

Inverse time characteristics<br />

GMP22/40 Type<br />

Description<br />

- Wide and adjustable current range<br />

- Adjustable trip time (trip class 5-30)<br />

- Designed suitable for use with contactors<br />

Directly mountable on the Metasol contactors (Pin type)<br />

Separate mount versions are also available<br />

Separately mountable on 35mm DIN rail or with screws<br />

- 1NO+1NC trip contacts<br />

- Manual reset as standard (Automatic reset optional)<br />

Front face configuration<br />

Current setting<br />

GMP22 type<br />

0.3 ~ 1.5A<br />

1 ~ 5A<br />

1.1 ~ 22A<br />

GMP40 type<br />

4 ~ 20A<br />

8 ~ 40A<br />

LED indicator<br />

Operation status indication<br />

- Normal operating<br />

- <strong>Overload</strong><br />

- Phase unbalance<br />

Trip cause indication<br />

- Overcurrent<br />

- Phase loss<br />

- Reverse phase<br />

Test/Reset button<br />

Trip time setting<br />

- 0 to 30 sec<br />

- Set time is the trip time<br />

at 6 x set current<br />

Extended protective functions<br />

Types (GMP22/40-) -2P, -2T, -2S -3P, -3T, -3S -3PR, -3TR, -3SR<br />

Number of sensors 2CT 3CT 3CT<br />

Overcurrent<br />

Phase failure<br />

Functions Locked rotor<br />

Phase unbalance<br />

Reverse phase<br />

Technical information<br />

Certificate<br />

CE, ULcUL<br />

Relay control voltage<br />

100 to 260V AC 50/60Hz<br />

Auxiliary contact<br />

3A/250VAC at resistive load<br />

1NO (97-98) + 1NC (95-96)<br />

Setting tolerance<br />

Current ± 5%<br />

Time ± 5% (or ± 0.5sec)<br />

Insulation resistance<br />

Min 100MΩ at 500V DC<br />

Impulse withstand voltage 5kV (IEC 61000-4-5)<br />

Fast transient burst 2kV (IEC 61000-4-4)<br />

Ambient temperature<br />

-25 to 70℃ for operation<br />

-30 to 80℃ for storage<br />

Humidity<br />

30 to 90% RH<br />

12


Inverse time characteristics<br />

GMP22/40 Type<br />

Selection (GMP22 Type)<br />

To mount on 35mm DIN rail<br />

Cable connection part can be modified<br />

between screw connection and<br />

passing CT hole<br />

Mount/Connection Sensor Setting range Catalog No.<br />

Directly on a contactor 2-sensor 0.3 - 1.5A GMP22 - 2P∙1.5<br />

(2 CT) 1 - 5A GMP22 - 2P∙5<br />

4.4 - 22A GMP22 - 2P∙22<br />

3-sensor 0.3 - 1.5A GMP22 - 3P∙1.5<br />

(3 CT) 1 - 5A GMP22 - 3P∙5<br />

4.4 - 22A GMP22 - 3P∙22<br />

3-sensor 0.3 - 1.5A GMP22 - 3PR∙1.5<br />

Reverse phase 1 - 5A GMP22 - 3PR∙5<br />

detection 4.4 - 22A GMP22 - 3PR∙22<br />

Separate mount 2-sensor 0.3 - 1.5A GMP22 - 2S∙1.5<br />

(2 CT) 1 - 5A GMP22 - 2S∙5<br />

Cable connection 4.4 - 22A GMP22 - 2S∙22<br />

with a screw 3-sensor 0.3 - 1.5A GMP22 - 3S∙1.5<br />

(3 CT) 1 - 5A GMP22 - 3S∙5<br />

4.4 - 22A GMP22 - 3S∙22<br />

3-sensor 0.3 - 1.5A GMP22 - 3SR∙1.5<br />

Reverse phase 1 - 5A GMP22 - 3SR∙5<br />

detection 4.4 - 22A GMP22 - 3SR∙22<br />

Separate mount 2-sensor 0.3 - 1.5A GMP22 - 2T∙1.5<br />

(2 CT) 1 - 5A GMP22 - 2T∙5<br />

Connection 4.4 - 22A GMP22 - 2T∙22<br />

without a screw 3-sensor 0.3 - 1.5A GMP22 - 3T∙1.5<br />

- cables pass (3 CT) 1 - 5A GMP22 - 3T∙5<br />

through CT holes 4.4 - 22A GMP22 - 3T∙22<br />

3-sensor 0.3 - 1.5A GMP22 - 3TR∙1.5<br />

Reverse phase 1 - 5A GMP22 - 3TR∙5<br />

detection 4.4 - 22A GMP22 - 3TR ∙22<br />

Selection (GMP40 Type)<br />

Mount/Connection Sensor Setting range Catalog No.<br />

Directly on a contactor 2-sensor 4 - 20A GMP40-2P∙20<br />

(2 CT) 8 - 40A GMP40-2P∙40<br />

3-sensor 4 - 20A GMP40-3P∙20<br />

(3 CT) 8 - 40A GMP40-3P∙40<br />

3-sensor 4 - 20A GMP40-3PR∙20<br />

Reverse phase 8 - 40A GMP40-3PR∙40<br />

detection<br />

Separate mount 2-sensor 4 - 20A GMP40-2S∙20<br />

(2 CT) 8 - 40A GMP40-2S∙40<br />

Cable connection 3-sensor 4 - 20A GMP40-3S∙20<br />

with a screw (3 CT) 8 - 40A GMP40-3S∙40<br />

3-sensor 4 - 20A GMP40-3SR∙20<br />

Reverse phase 8 - 40A GMP40-3SR∙40<br />

detection<br />

Separate mount 2-sensor 4 - 20A GMP40-2T∙20<br />

(2 CT) 8 - 40A GMP40-2T∙40<br />

Connection 3-sensor 4 - 20A GMP40-3T∙20<br />

without a screw (3 CT) 8 - 40A GMP40-3T∙40<br />

- cables pass 3-sensor 4 - 20A GMP40-3TR∙20<br />

through CT holes Reverse phase 8 - 40A GMP40-3TR∙40<br />

detection<br />

13


Electronic motor protection relays<br />

Definite time characteristics<br />

GMP60-T(E) Type<br />

Description<br />

- Small size, economical<br />

- Delay time setting in starting and operation<br />

- Over current, phase failure protection<br />

- Definite time characteristics<br />

- Wide current setting range<br />

- Screw or Din-rail mounting<br />

Extended protective functions<br />

Types GMP60-T GMP60-TE GMP60-TA<br />

Number of sensors 2CT 2CT 2CT<br />

Overcurrent<br />

Functions<br />

Note)<br />

Phase failure<br />

Locked rotor<br />

Auto reset - -<br />

* Only two-phase protection is available.<br />

Ratings (Tunnel type)<br />

Large current over 60A can be applied<br />

through additional current transformers<br />

Model<br />

Type<br />

No. of CT<br />

Current setting range (A)<br />

Operating time characteristics<br />

Starting time<br />

Time setting<br />

Operating time<br />

(sec)<br />

Reset time<br />

Allowable Current<br />

error Time<br />

Voltage<br />

Control power<br />

Frequency<br />

Contact Note3)<br />

Aux. s/w Ratings<br />

Operation<br />

Insulation resistance<br />

Surge insurance (IEC 61000-4-5)<br />

Fast transient burst (IEC 61000-4-4)<br />

Environment Operation<br />

Temperature Storage<br />

Relative humidity<br />

Trip indicator<br />

Dimension (mm) W×H×D<br />

Mounting type<br />

Certification<br />

GMP-60T GMP-60TE GMP-60TA<br />

Tunnel type<br />

2<br />

0.5~6, 3~30, 5~60<br />

Definite time characteristics<br />

0~30<br />

0~15 5 5<br />

Manual reset 0~120<br />

±5%<br />

±5% (or ±0.5 sec)<br />

220V (AC 24V/48V/110V/380V(440)) Note2) , AC 180~480V<br />

50 / 60Hz<br />

1SPDT (1c)<br />

5A 250Vac, resistive load<br />

95 96close<br />

Min. 50MΩ at 500Vdc<br />

5kV<br />

2kV<br />

-25~70℃<br />

-50~80℃<br />

46~85 RH (No freezing)<br />

LED<br />

72×63×69<br />

Separate mount (Screw & Din-rail)<br />

UL, cUL, CE -<br />

Note) 1. Under phase failure condition over current flows. The <strong>EMPR</strong> tripped if it is over the setting over current<br />

2. ( ) are optional specifications<br />

Tunnel type <strong>EMPR</strong> protects the current under 0.1A<br />

If we increase the number of times of a wire pass through the CT (Tunnel), the <strong>EMPR</strong> can detect the lower current<br />

No. of times to pass through<br />

Current setting range<br />

1 0.5~6<br />

2 0.25~3<br />

3 0.17~2<br />

4 0.12~1.5<br />

14


Ampere meter function<br />

GMP60-TD(a) Type<br />

Description<br />

- Definte time characteristics<br />

- Delay time setting in starting and operation<br />

- Over current, phase failure protection<br />

- Definite time characteristics<br />

- Wide current setting range<br />

- Screw or Din-rail mounting<br />

- Display the causes of the fault and the values<br />

Extended protective functions<br />

Functions<br />

* Only two-phase protection is available.<br />

Types GMP60-TD GMP60-TDa<br />

Number of sensors 2CT 2CT<br />

Overcurrent<br />

Note1)<br />

Phase failure<br />

Locked rotor<br />

Under current -<br />

Auto reset -<br />

Ratings (Tunnel type)<br />

Model<br />

GMP60-TD<br />

GMP60-TDa<br />

Type<br />

Tunnel type<br />

No. of CT<br />

2<br />

Current setting range (A)<br />

0.5~60<br />

Operating time characteristics<br />

Definite time characteristics<br />

Time setting<br />

(sec)<br />

Delay time<br />

Operating time<br />

Reset time<br />

1~60<br />

0.5~30<br />

Manual reset<br />

1~20min<br />

Allowable<br />

Current<br />

±5%<br />

error<br />

Time<br />

±5% (or ±0.5 sec)<br />

Control power<br />

Voltage<br />

Frequency<br />

AC 110/220V (±10%)<br />

50 / 60Hz<br />

Contact Note2)<br />

2SPST (1a1b)<br />

Aux. s/w<br />

Ratings<br />

5A 250Vac, resistive load<br />

Operation<br />

95 96close 97 98open<br />

Insulation resistance<br />

Min. 50MΩ at 500Vdc<br />

Surge insurance (IEC 61000-4-5)<br />

5kV<br />

Fast transient burst (IEC 61000-4-4)<br />

2kV<br />

Environment<br />

Operation<br />

-25~70℃<br />

Temperature<br />

Storage<br />

-50~80℃<br />

Relative humidity<br />

46~85 RH (No freezing)<br />

Trip indicator<br />

7-Segment<br />

Dimension (mm) W×H×D<br />

72×63×69<br />

Mounting type<br />

Separate mount (Screw & Din-rail)<br />

Note) 1. Under phase failure condition over current flows. The <strong>EMPR</strong> tripped if it is over the setting over current<br />

2. When power applied the Aux. contact operate<br />

Tunnel type <strong>EMPR</strong> protects the current under 0.1A<br />

If we increase the number of times of a wire pass through the CT (Tunnel), the <strong>EMPR</strong> can detect the lower current<br />

No. of times to pass through Current setting range Current Ratio<br />

1 0.5~6 1<br />

2 0.25~3 0.5<br />

4 0.12~1.5 0.25<br />

15


Electronic motor protection relays<br />

Definite time characteristics with 3CT<br />

GMP60-3T(R) Type<br />

Description<br />

- Cable connecting through CT holes (option: with screw)<br />

- Auxiliary contact: 2SPST (1a1b at energization)<br />

- Wide and adjustable current range (0.5~60A)<br />

- D-time: 0.2~60 sec. / O-time: 0.2~15 sec.<br />

- Control voltage: AC100~245V 50/60Hz<br />

- Manual(electrical) reset as standard<br />

- Applicable to inverter at the secondary circuit (except GMP60-3TR)<br />

GMP60-3T<br />

GMP60-3TR<br />

Extended protective functions<br />

Types GMP60-3T GMP60-3TR<br />

Terminal Lug<br />

Number of sensors 3CT 3CT<br />

Overcurrent<br />

Phase failure<br />

Protective<br />

Locked rotor<br />

functions<br />

Phase unbalance<br />

Reverse phase -<br />

Storing the last fault cause<br />

Selection<br />

Mount/Connection Optional function Setting range Catalog No.<br />

∙Separate mount None 0.5 - 60A GMP60-3T<br />

∙Cable Connection<br />

through CT holes Reverse phase 0.5 - 60A GMP60-3TR<br />

Large current over 60A can be<br />

applied through additional current<br />

transformers<br />

Technical information<br />

Mounting<br />

On 35mm rail or panel with screws<br />

Setting tolerance<br />

Current ± 5%<br />

Time ± 5% (or ±0.5sec)<br />

Frequency<br />

50/60Hz<br />

Auxiliary contact rating 5A/250VAC at resistive load<br />

Insulation resistance<br />

Min 100MΩ at 500V DC<br />

Surge insurance 5kV (IEC 61000-4-5)<br />

Fast transient burst 2kV (IEC 61000-4-4)<br />

Ambient temperature<br />

-25 to 70℃ for operation<br />

-30 to 80℃ for storage<br />

Humidity<br />

30 to 90% RH<br />

Operating indication<br />

Red/Green 2-color LED, Red LED<br />

Standard<br />

IEC60947-1<br />

16


For ground fault current protection<br />

GMP60-3TZ(R), 3TN(R) Type<br />

Description<br />

- Cable connecting through CT holes<br />

- Auxiliary contact: 2SPST (1a1b at energization)<br />

- Wide and adjustable current range (0.5~60A)<br />

- Definite time characteristics<br />

D-time: 0.2~60sec. / O-time: 3sec.<br />

- With 3 sensors (CT)<br />

- Control voltage: AC100~245V (50/60Hz)<br />

GMP60-3TZ, 3TZR<br />

GMP60-3TN, 3TNR<br />

Extended protective functions<br />

Types GMP60-3TZ, 3TN GMP60-3TZR, 3TNR<br />

Terminal Lug<br />

Number of sensors 3CT 3CT<br />

Overcurrent<br />

Phase failure<br />

Protective Ground fault<br />

functions Locked rotor<br />

Phase unbalance<br />

Reverse phase -<br />

Storing the last fault cause<br />

Selection<br />

Mount/Connection Ground fault current Optional function Setting range Catalog No.<br />

Zero phase current<br />

∙Separate mount (0.1~2.5A) None 0.5 - 60A GMP60-3TZ<br />

∙Cable Connection *ZCT required<br />

through CT holes Reverse phase 0.5 - 60A GMP60-3TZR<br />

Residual current<br />

(0.5~6A) None 0.5 - 60A GMP60-3TN<br />

Note) Use ZCT for <strong>EMPR</strong>, 100mA/40 ~ 55mV<br />

Reverse phase 0.5 - 60A GMP60-3TNR<br />

Technical information<br />

Mounting<br />

On 35mm rail or panel with screws<br />

Setting tolerance<br />

Current ± 5%<br />

Time ± 5% (or ±0.5sec)<br />

Frequency<br />

50/60Hz<br />

Auxiliary contact rating 5A/250VAC at resistive load<br />

Insulation resistance<br />

Min 100MΩ at 500V DC<br />

Surge insurance 5kV (IEC 61000-4-5)<br />

Fast transient burst 2kV (IEC 61000-4-4)<br />

Ambient temperature<br />

-25 to 70℃ for operation<br />

-30 to 80℃ for storage<br />

Humidity<br />

30 to 90% RH<br />

Operating indication<br />

Red/Green 2-color LED, Red LED<br />

Standard IEC 61000, KEMC 1120<br />

17


Electronic motor protection relays<br />

Inverse time characteristics<br />

GMP80 Type<br />

Description<br />

- Wide and adjustable current range<br />

- Adjustable trip time (trip class 5-30)<br />

- Separately mountable on 35mm DIN rail or with screws<br />

- 1NO+1NC trip contacts<br />

- Manual reset as standard (Automatic reset optional: GMP80-2SA)<br />

Front face configuration<br />

Test/Reset button<br />

LED indicator<br />

Current setting<br />

Trip time setting<br />

Operation status indication<br />

- Normal operating<br />

- Phase unbalance<br />

- Overcurrent<br />

- Phase loss<br />

- Reverse phase (R-type)<br />

16 ~ 80A<br />

- 0 to 30 sec<br />

- Set time is the trip time<br />

at 6 x set current<br />

Extended protective functions<br />

Types (GMP80-) 2S 2SA 3S 3SR<br />

Number of sensors 2CT 2CT 3CT 3CT<br />

Overcurrent<br />

Phase loss<br />

Functions Locked rotor<br />

Phase unbalance - -<br />

Reverse phase - - -<br />

Auto reset - - -<br />

Selection<br />

Mount/Connection Sensor Setting range Catalog No.<br />

Separate mount 2-sensor 16 - 80A GMP80-2S<br />

(2 CT)<br />

Cable connection 3-sensor 16 - 80A GMP80-3S<br />

with a screw<br />

(3 CT)<br />

3-sensor 16 - 80A GMP80-3SR<br />

Reverse phase detection<br />

Technical information<br />

Certificate<br />

CE, ULcUL<br />

Relay control voltage<br />

100 to 260V AC 50/60Hz<br />

Auxiliary contact<br />

3A/250VAC at resistive load<br />

1NO (97-98) + 1NC (95-96) (When power applied)<br />

Setting tolerance Current ± 5%<br />

Time ± 5% (or ±0.5sec)<br />

Insulation resistance<br />

Min 100MΩ at 500V DC<br />

Surge insurance 5kV (IEC 61000-4-5)<br />

Fast transient burst 2kV (IEC 61000-4-4)<br />

Ambient temperature<br />

-25 to 70℃ for operation<br />

-30 to 80℃ for storage<br />

Humidity<br />

30 to 90% RH<br />

18


Characteristics DMP Series<br />

DMP-S/SZ/SI, T/TZ/TI Type<br />

Unit type or extension type is available<br />

- Extension type:Remotely mounts the display unit on the panel surface<br />

Ampere meter function: current and setting value by press the display button<br />

Select the inverse time or definite time<br />

Display the causes of the fault and the values<br />

Protect function<br />

Over current Depend on setting time Selectable the inverse/definite<br />

Phase failure Within 3seconds Over 70% of the rate of unbalance<br />

Phase unbalance Within 5seconds Over 50% of the rate of unbalance<br />

Reverse phase Within 0.1seconds Function enable<br />

Stall Within 5seconds Over 180% of the setting current<br />

Lock Within 0.5seconds Setting 200~900% of rated current<br />

Under current Within 3seconds Setting 30~70% of rated current<br />

Ground fault Note) Selectable 0.05~1.0seconds Grounded current setting by dip s/w (100~2500mA)<br />

Short circuit Within 50ms 300~1800% of rated current<br />

Note) Lock protection is operated after setting D-time in case of definite time type<br />

Extention type (with cable)<br />

Function selection<br />

FUNC Sel Description<br />

1. CHA Inv/dEF Operating characteristics setting (Inverse/definite time type)<br />

2. dEF Note1) 0~30 (S) Setting the operating time (In definite type)<br />

3. r.P oFF/on Reverse phase enable<br />

4. Und oFF/30~70 (%) Under current enable and setting<br />

5. Alt oFF/60~110 (%) Alerting enable and setting (DMP-S, T type)<br />

5. g-F oFF/0.05~1.0 (S) Ground fault enable and setting (DMP-Z type)<br />

5. Sho oFF/300~1800 (%) Short current enabling and setting (DMP-I type)<br />

6. Stl oFF/on Stall enable<br />

7. Loc oFF/200~900 (%) Lock enable and setting<br />

8. Ct 1~120 CT ratio setting<br />

9. P.F on/oFF Phase fault enable<br />

A. gFd Note2) oFF/on Setting delay of ground fault (DMP-Z type)<br />

b. StA 0~120 Operating time setting by month (DMP-a type)<br />

c. StH 10~730 Operating time setting by hour (DMP-a type)<br />

d. tAH A000,000.0 Displaying total operating time (month, hour) (DMP-a type)<br />

E. rAH A000,000.0 Displaying operating time (month, hour) (DMP-a type)<br />

Sto Sto Store<br />

Note) 1. 2.dEF is only displayed when dEF s selected in a 1.CHA mode<br />

2. Functions for A to E are available for only DMP-a type.<br />

Ratings<br />

Model DMP-S/Sa, T/Ta, SI DMP-SZ/SZa/SI, TZ/TZa/TI<br />

Type Wiring method S: Screw, T: Tunnel<br />

Panel mount<br />

Operating characteristics<br />

Unit or Extension<br />

Inverse/definite type<br />

Alerting function Variable between 60 and 110%<br />

Current range (A) 06: 0.5~6, 36: 3~36, 60: 5~60<br />

Setting time Definite Delay (D-T) 0~60seconds<br />

Inverse<br />

Reset type<br />

Operating (O-T)<br />

0~30seconds<br />

0~60seconds<br />

Manual reset<br />

Operating voltage AC 110V/220V (±10%)<br />

voltage Frequency 50/60Hz<br />

Aux. contacts<br />

ZCT input (07-08) 200mA/110mV (ZCT) [30∅, 50∅, 65∅, 80∅]<br />

3A/250Vac resistive load<br />

Indicate 7-segment 3-phase current value, fault cause<br />

Mounting<br />

Certification<br />

Bar-LED arrays Load ratio (60~110%)<br />

35mm Din-rail/Panel<br />

UL, cUL, CE (Except DMP36 type)<br />

19


Electronic motor protection relays<br />

Characteristics IMP Series<br />

IMP-C Type<br />

MODBUS RS-485 Communication or 4~20mA analogue output<br />

3 phase ampere meter function: Check the 3 phase current and setting value by press the<br />

display button<br />

Select the Thermal inverse/inverse time or definite time<br />

Easy to operate: Set the most function by the operation button and knob<br />

Display the causes of the fault and the values<br />

Adjustable wide current range (0.5~100A)<br />

Protect function<br />

Over current Depend on setting time Selectable the inverse/definite<br />

Phase failure Within 1.5seconds Over 70% of the rate of unbalance<br />

Phase unbalance Within 3seconds 10~70% of the rate of unbalance<br />

Reverse phase Within 0.1seconds Function enable<br />

Stall Within 3seconds setting 150~500% of rated current<br />

Lock Note1) Within 0.5seconds Setting 200~800% of rated current<br />

Under current Within 3seconds Setting 30~90% of rated current<br />

Selectable 0.05, gF: 0.03/0.05/0.1~3A<br />

Ground fault Note2) 0.1~1.0seconds<br />

gn: 20~500% of the FLC min<br />

Note) 1. Lock protection is operated after setting D-time in case of definite time selected.<br />

2. 12. gF Zero sequence CT, 13. gn Residual circuit sensing.<br />

Setting Menu (A Group)<br />

Setting Menu (B Group)<br />

Extention type (with cable)<br />

Menu Setting Value Item Default Value Menu Setting Value Item Default Value<br />

1.CHA dEF/th/n-th<br />

Operation Characteristics (Definite Time /<br />

Heat Accumulation Inverse Time /Inverse Time) n-th<br />

1.E-r On/OFF Electric Recovery On<br />

2.A-r OFF, 1~20 min Automatic Recovery (Minute) OFF<br />

2.O-t 1~60s Operation Time (sec) 60<br />

3.r-t Hour/Minute Operation Time Time Check<br />

3.d-t 1~200s Operation Delay (sec) In chase of dEF<br />

4.Srt OFF, 1~8760Hour Operation Time Setup (Hour) -<br />

4.r-C 0.5~10A/5~100A Rated Current Max.<br />

5.s-d 2009/01.01/00:00 YY/MM/DD/ HH:MM -<br />

5.Ctr 0.25, 0.5, 1~200 CT Ratio (4 times, twice, once) 1<br />

6.Trt Day/hour:minute Total Operation Time Time Check<br />

6.Loc OFF, 200~800% Lock Protection (sec) OFF<br />

A.t-d 0.5~10/5~100A 20mA Output Setup A420<br />

7.StL OFF, 150~500% (sec) Stall Protection OFF<br />

A.Adr 1~247 Communication Address<br />

8.P-F OFF/On Open Phase OFF<br />

b.bps 96/192/384 Communication Speed<br />

9.P-U OFF, 10~70% Unbalance Protection (%) OFF<br />

c.S-P On/OFF SWAP<br />

M485 Model<br />

10.rP OFF/On Reverse Phase OFF<br />

11.UC OFF, 30~90% Low Current Protection (%) OFF<br />

Note) 1. When the power is supplied first or is resupplied after a power<br />

12.gF 0FF, 0.03, 0.05/0.1~3A<br />

Ground Fault Operation Current<br />

failure, must set up the date (5.S-d).<br />

(Zero-Phase-Sequence Current) (A) OFF<br />

2. Automatic recovery is only possible in case of an excess<br />

Ground Fault Operation Current<br />

13.gn OFF, 20~500% (FLCmin)<br />

(Post-Arc Current) (FLCmin)<br />

OFF<br />

current trip.<br />

14.gt 0.05, 0.1~1.0s Ground Fault Operation Time (Current) -<br />

15.gd On/OFF Ground Fault Delay During Start ON<br />

16.IC OFF, 500~1000% Instantaneous Protection (%) OFF<br />

17.AL I-tp,I- AL, ALo, U-C, OrH 07-08 setting I-tp<br />

18.Ar On,60~110% On,60 0% Alert setting Only “ALo” Note) 1. When the rated current S/W is 100A, the CT ratio is not displayed.<br />

19.cS 1a1b, 2a, 2b Contact setting 1a1b<br />

2. Some menus are not displayed if relevant functions are not available.<br />

20<br />

Ratings<br />

Model<br />

IMP-C-NO, M485, A420<br />

Type Wiring method Tunnel<br />

Panel mount<br />

Unit or Extension<br />

Operating characteristics<br />

defin/TH-Inv./n-TH<br />

Alerting function Variable between 60 and 110%<br />

Current range (A) 0.5~100<br />

Setting time Definite Delay (D-T) 1~200seconds<br />

Operating (O-T)<br />

0~30seconds<br />

Inverse/TH-Inverse time<br />

0~60seconds<br />

Reset type<br />

Manual reset<br />

Operating Control power [A1(+), A2(-)] AC 85~245V, AC 24~36V (50/60Hz)<br />

ZCT input (Z1, Z2) 200mA/110mV (ZCT)[30∅, 50∅, 65∅, 80∅]<br />

Aux. contacts (2a, 2b, 1a1b) OL, GR 2-SPST (95~98)<br />

AL (07-08)<br />

5A/250Vac resistive load<br />

Indicate 7-segment 3-phase current value, fault cause 5point<br />

Bar-LED arrays Load ratio (60~110%)<br />

Mounting<br />

35mm Din-rail/Panel<br />

Communication<br />

A420: Analog, M485: Modbus<br />

Certification<br />

CE


Setting method<br />

GMP Series Inverse time<br />

1. Check the rated voltage and apply the control power to A1 and A2 terminal<br />

2. Check the TEST/RESET button<br />

1) When you press the ‘Test/Reset’ button, the O.L LED is turned on and the <strong>EMPR</strong> is tripped<br />

2) When you press the ‘Test/Reset’ button under the <strong>EMPR</strong> is tripped, the O.L LED is turned<br />

off and the <strong>EMPR</strong> is reset<br />

3) Auto reset function: When it is tripped by the over current, it is reset after 1 Min.(Optional)<br />

3. Set the operating time<br />

The operating time is set on the base of 600% of the rated current in the characteristic curve<br />

1) Set the operating time by considering the operating time and start current according to the<br />

types of the load<br />

2) If the time knob is set to 10sec, the <strong>EMPR</strong> is tripped when the start current (600% of the<br />

rated current) is applied for 10sec<br />

Caution) The <strong>EMPR</strong> with inverse time characteristics can be tripped to protect the motor when the motor is started a few times continuously<br />

When a motor is frequently changing the rotating direction (forward and reverse), set the operating time longer For the crane and hoist<br />

use, select the <strong>EMPR</strong> with definite time characteristics<br />

4. Set the operating current<br />

Set the current by considering the rated current of a motor to protect from the over current<br />

1) Check the rated current of a motor is within the current setting range of an <strong>EMPR</strong><br />

2) Set the ‘RC’ (Rated current) knob to the maximum value and then start a motor<br />

3) Under normal motor operation, rotate the ‘RC’knob to the counterclockwise until the<br />

‘O.L’LED flickers The current at this point in the 100% current rating under real load<br />

4) At this point, rotate the ‘RC’knob to the clockwise until the ‘O.L’LED turned off.<br />

Ex) When the ‘O.L’ LED flickering at 20A, the setting current will be 22A(=20x1.1)<br />

Note) The brackets for connection is offered standard<br />

5. Check status of operation by LED<br />

1) In case of overcurrent<br />

If there will be an overcurrent during motor operation, the red color of LED will flicker at 0.4<br />

second intervals. After tripping because of overcurrent, the red color of LED will light up.<br />

2) In case of phase failure<br />

If there will be a phase failure in three phase load, it will be tripped within 3 seconds.<br />

Note) 2CT <strong>EMPR</strong> can protect motor from R or T phase failure.<br />

3) In case of phase unbalance<br />

If phase unbalance rate is over 50%, FAULT LED will flicker 0.4 second intervals.<br />

4) In case of Reverse phase<br />

Red & green color LED will flicker alternately.<br />

Condition LED Status LED Diagram Remark<br />

Operating status Tripped status<br />

Phase failure (3CT)<br />

Normal<br />

Over current<br />

Phase unbalance<br />

(30~50%)<br />

Over current<br />

R<br />

S<br />

T<br />

Phase failure (2CT)<br />

LED OFF<br />

0.4 Second<br />

intervals<br />

0.4 Second<br />

intervals<br />

O.L LED<br />

light up<br />

1 time for 3<br />

seconds<br />

2 time for 3<br />

seconds<br />

2 time for 3<br />

seconds<br />

Red LED light up for 0.9 sec<br />

LED goes off for 0.1 sec<br />

0.9 0.1<br />

GMP 80-3S/3SR model, only<br />

red color LED will flicker.<br />

GMP 80-3S/3SR model,<br />

O.L LED will light up and<br />

also FAULT LED will flicker.<br />

Reverse phase (3CT)<br />

Red & Green color LED<br />

flicker alternately<br />

GMP 80-3S/3SR model,<br />

Red/Green LED will flicker.<br />

Note) There are two red color LEDs for O.L (<strong>Overload</strong>) & Fault in the model of GMP80-3S/SR<br />

21


Electronic motor protection relays<br />

Setting method<br />

GMP Series Definite time<br />

Tunnel type mounting<br />

1. Check the Test/Reset button operation<br />

1) Check if the wiring is correct (Refer to the wiring diagram)<br />

2) Set the 'D-Time' and 'O-Time'' knob to the min. ratings<br />

3) When the 'Test' button is pressed under tripped condition,<br />

the 'O.L' LED is turned off<br />

Note) In operation, even though you press the 'Test/Reset' button, the <strong>EMPR</strong> do not trip<br />

O.L LED<br />

D-Time knob<br />

Test/Reset button<br />

O-Time knob<br />

RC(A) knob<br />

2. Set the operating time<br />

● D-time (Delay time): 0~30 sec<br />

The motor starting current, which flows when the motor is starting, is<br />

generally 600% of the rated current. It is the time during which the<br />

<strong>EMPR</strong> do not operated by over-current during the starting time<br />

1) Set the delay time by use of the 'D-time' knob<br />

2) In case you do not know the delay time, start the motor by setting the 'Dtime'<br />

knob to the max. position and after checking the time during which the<br />

staring current become stable, set the D-time (In general , the setting time is<br />

3~5 seconds)<br />

Time(sec)<br />

● The operating time is the time during which the <strong>EMPR</strong> tripped by the<br />

over-current. The <strong>EMPR</strong> is tripped after the selected operation time<br />

1) Set the operation time by the 'O-time' knob<br />

2) If you set the 'O-time' to the min value, the <strong>EMPR</strong> is tripped at once<br />

Note) Generally set it to 4~6 seconds<br />

Definite time characteristics curve<br />

Current (%)<br />

3. Set the operating current<br />

1) Start the motor by setting the 'RC' knob to the maximum position<br />

2) Under operating condition, rotate the 'RC' knob to the<br />

counterclockwise until the 'O.L' LED turned on & off. The current at<br />

this point is the value (100%) under real load condition<br />

3) Rotate the 'RC' knob to the clock-wise until the 'O.L' LED turned off.<br />

Ex) When the ‘O.L’ LED flickering at 20A, the setting current will<br />

be 22A(=20x1.1)<br />

(ex: When the 'O.L' LED settings at 21A, the setting current will be 23A (=21*1.1))<br />

4. Check the LED condition when operation<br />

1) Over-current<br />

‐The <strong>EMPR</strong> is not tripped during the D-time under over-current but<br />

the O.L LED turned on and off to indicate that the over-current flows<br />

‐If the <strong>EMPR</strong> is tripped after D-time the O.L LED turned on<br />

Condition<br />

Operation normal<br />

Overcurrent<br />

Off<br />

Flicker<br />

Red O.L LED<br />

Note<br />

Trip over-current<br />

On<br />

The <strong>EMPR</strong> is tripped<br />

22


Setting method<br />

GMP60-TD(a) Type<br />

● Function & Setting menu<br />

1) Automatic reset setting will work in the event of overcurrent trip<br />

2) Func. A and b are to check the elapse time, not for setting<br />

3) Undercurrent protection function will work at the current flow more than 0.4A<br />

4) In case of changing the rating DIP S/W FUNC #1 should be changed accordingly<br />

5) Function setting is allowable at TEST mode<br />

- Turn off the power before changing a current type switch,<br />

and then be sure to adjust the current in the menu<br />

●Setting Menu<br />

FUNC SEL Description Remarks<br />

Current type selection Set the same with rated current S/W<br />

Trip time setting -<br />

Time delay setting -<br />

Rated current setting -<br />

Current ratio setting -<br />

Phase loss enable -<br />

Undercurrent setting For TDa model only<br />

Automatic reset setting For TDa model only<br />

Operation hour setting For TDa model only<br />

Total running hour check For TDa model only<br />

Running hour check For TDa model only<br />

Store -<br />

Note) 1. If operation hour set at is elapsed is displayed and the relay operates normally. (There is no additional relay output)<br />

2. How to check and<br />

Display<br />

How to check<br />

Press SEL Day displayed Press SEL Hour, Min displayed<br />

Press SEL Operation hour displayed Press SEL Day displayed<br />

Press SEL Min displayed<br />

3. When power is OFF the data in unit of minute is deleted at<br />

4. Operation hour at is the total running hour before the motor is oFF and displayed in Day, Hour and Min.<br />

When motor is OFF the data is deleted.<br />

●Fault status configuration<br />

Protection FND Description Remarks<br />

Over current O - L More than set current : Within the set time<br />

Undercurrent U - C Lower than the undercurrent set ratio : Within 3S GMP60TDa<br />

Phase Loss<br />

PF - r Over 70% of the rate of unbalance : Within 3S R Phase Loss<br />

PF - t Over 70% of the rate of unbalance : Within 3S T Phase Loss<br />

LOCK Loc More than lock set current ratio : Within 1S<br />

Approaching<br />

Running Time<br />

OrH When Running time approaches at setting time GMP60TDa<br />

Note) When the ‘FUN’ Key and ‘SEL’ Key are pushed simultaneously, a last trip cause appears on the disply window.<br />

23


Electronic motor protection relays<br />

Setting method<br />

GMP60-3TZ(R) / 3TN(R) Type<br />

● Trip curve: definite time characteristics<br />

● Protective function: overcurrent, locked rotor, phase loss, phaseun<br />

balance, ground fault (and phase reverse)<br />

1) Overcurrent: trip within 3 sec. after D-time at 105% or more<br />

2) Locked rotor: trip within 1 sec. after D-time at 300% or more<br />

3) Phase loss: trip within 3 sec. (phases unbalance rate over 70%)<br />

4) Phase unbalance: trip within 5 sec. (phases unbalance rate over 50%)<br />

5) Ground fault: trip within 0.5 sec. after D-time at over 110% or under<br />

90% of set value<br />

6) phase reverse: trip within 1 sec. when any two phases out of three<br />

● Overcurrent trip time<br />

1) Time delay(D-time) setting: between 0.2-60 sec.<br />

2) Trip time(O-time) setting: fixed at 3 sec.<br />

● Last fault cause data stored<br />

- to display it press TEST/RESET button 2 times within 0.5 sec.<br />

- PWR LED flicking in case of no fault<br />

Note) In case of load less than minimum rating of <strong>EMPR</strong> make the number of penetrating through CT more than 2 times.<br />

If not, error may happen to phase loss .<br />

1<br />

2 3 4<br />

5 6 7<br />

Note) 1.Make power off before changing the rated current with S/W 1<br />

2.The setting range of RC (A) KNOB 6 is recognized as 0.5 ~ 6A or 5 ~<br />

60According to the setting value of S/W 1. The value of the scale for<br />

RC (A) KNOB 6 is 0.5, 1, 2, 3, 4, 5, 6 or 5, 10, 20, 30, 40, 50,<br />

60(A)from the left.<br />

3.Last fault cause function indicates the LED status for the last TRIP.<br />

8<br />

● Status of LED configuration<br />

NO<br />

1<br />

2<br />

Function Setting Description<br />

Remark<br />

6A/60A Slide switch Maximum rated current (6A/60A) setting -<br />

PWR. Red LED Lights up when power is ON Blinking in the failure mode<br />

3<br />

Overcurrent / unbalance in progress:<br />

Overcurrent TRIP:<br />

Phase loss (unbalance) TRIP<br />

FAULT Red / Green LED ∙R-phase:<br />

∙S-phase:<br />

∙T-phase:<br />

Red LED<br />

Green LED<br />

Reverse phase:<br />

4<br />

5<br />

6<br />

GF Red LED Lights up after blinking in the event of ground fault -<br />

D-TIME (S) KNOB Delay time (0.2 to 60 sec.) -<br />

RC (A) KNOB Rated current setting: 0.5~6A/5~60A -<br />

7<br />

GR (A)<br />

KNOB<br />

Sensitivity current setting (0.1~2.5A)<br />

Sensitivity current setting (0.5~6A)<br />

Zero phase current detection type<br />

Residual current detection type<br />

TRIP / RESET alternately perform<br />

Pressing 2 times within 0.5 sec.<br />

8<br />

TEST/RESET BUTTON 1. Check relay contacts - displays fault cause the final failure<br />

2. RESET cause is displayed<br />

24


Setting method<br />

DMP Series<br />

1. Check the operation of the Test/Reset button<br />

1) Check the wiring method<br />

2) Press the Test/Reset button and then test is displayed on<br />

the LED and the DMPR is tripped<br />

3) Press the Test/Reset button again and then it is reset<br />

Note) The Test/Reset is not available when a motor is rotating.<br />

R phase<br />

S phase<br />

T phase<br />

Test/Reset button<br />

FUNC button<br />

Digital display<br />

Bar graph<br />

Display button<br />

Sel button<br />

Current knob<br />

Time knob<br />

2. Shift the mode by pressing the FUNC key and then select the values by the Sel key<br />

1) First shift to the test mode by press the ”Test/Reset”button and then set the functions by press the ”FUNC”button<br />

2) Each time you press the”FUNC”button, the function mode switches from 1.CHA mode to Sto mode.<br />

When the mode that you want to change is displayed, push the ”Sel”button to select the value you want.<br />

After you select the value, press the ”FUNC”button to finish the settings and it displays the next mode<br />

3) If no button is pressed in the selection mode, it remains in that mode<br />

Alarm signal (Alert function)<br />

4) If you select the inverse time characteristics it skips the mode 2<br />

5.ALt<br />

AL(07-08) contact operation<br />

(Definite O-time) and go to the mode 3 (Reverse phase)<br />

5) Alt is the alert setting mode. It displays the load rate of the current<br />

1<br />

On<br />

setting value by the bar LED (60~110%)<br />

0<br />

- If the current is higher than the setting value, the bar LED is switched<br />

on and off and the AL relay (07-08)<br />

1<br />

make close and open in 1sec interval unit the <strong>EMPR</strong> is tripped (Prealarm<br />

function)<br />

0<br />

Off<br />

- If the 5. Alt mode is set to off, the AL relay make close after the <strong>EMPR</strong><br />

Normal<br />

Alarm<br />

is tripped (Normal open contact)<br />

6) To finish the settings you have to press the ”Sel”button in the Sto<br />

mode<br />

Setting Menu<br />

Alert setting<br />

value<br />

FUNC Sel Functions Note<br />

Inverse or definite time characteristics<br />

Default is inverse time characteristics<br />

Set the O-time (Definite time only)<br />

For D-time setting, use the time knob<br />

Reverse phases protection<br />

Default is “Off”<br />

Under current protection<br />

Default is “Off” Note1)<br />

Alarm function (With pre-alarm function)<br />

Default is “Off”(DMP-S, T type)<br />

Ground fault and Setting the operating time Default is “Off”(DMP-Z type)<br />

Short current Protection enabling and setting Default is “Off”(DMP-I type)<br />

Stall function<br />

Default is “Off”<br />

Lock function<br />

Default is “Off”<br />

CT ratio<br />

Default is 1:1 Note2) (DMP06 Modle)<br />

Phase failure<br />

Default is “On”to store<br />

Setting delay of Ground Fault<br />

Available for SZa/TZa<br />

Operating time setting (Month)<br />

Operating time setting (Hour)<br />

Displaying total operating time (Month, Hour)<br />

DMP-Sa/Ta/SZa/TZa model<br />

Displaying operating time (Month, Hour)<br />

Store<br />

Push the SEL button to store<br />

Trip setting<br />

value<br />

Trip<br />

Note) 1. Set the under current value from above 350mA<br />

2. Do not change the CT ratio in 36, 60 type<br />

3. When using DMP to loads over 60A, you should use DMP-06 and an external CT that secondary output is 5A<br />

4. When using external CT, maximum primary current is 600A<br />

25


Electronic motor protection relays<br />

Setting method<br />

DMP Series<br />

3. Adjust the operating time by the time knob<br />

● Inverse time characteristics<br />

1) Select the inverse time in the 1. CHA mode, the default operating time is 600% of the setting<br />

current<br />

2) The setting range of the operating time is 0~60sec. Set the time by considering the motor<br />

start time<br />

3) When it is over the setting time, the <strong>EMPR</strong> operate in accord with the hot characteristics curve<br />

● Definite time characteristics<br />

1) Select the definite in the 1. CHA mode, it is operated by the definite time characteristics<br />

2) D-time means the time that delays the operating time when the motor is starting<br />

3) The setting range of the operating time is 0~60sec. Set the time by considering the motor<br />

start time<br />

4) Set the O-time at the setting mode 2. dEF and the range is 0~30sec<br />

4. Adjust the operating current by the current knob<br />

1) Set the operating current based on the rated current that is described in the name plate.<br />

Generally set the 110~115% of the real load current in the normal load condition<br />

2) There are 3 types according to the current range (6 / 36 / 60). When you use the external CT<br />

you can see the real current by setting the CT ratio<br />

3) You can easily set the current value by refer to the load rate which is displayed on the bargraph<br />

(Approx. 90% load rate)<br />

Set the O-time<br />

to 10sec<br />

(Display only in<br />

definite time)<br />

R phase current<br />

Normal condition<br />

S phase current<br />

5. Check the setting state by the display key<br />

1) In normal condition it display the maximum current among the three phase current<br />

2) Each time you press the “Display”button you can see the current and values<br />

3) If no button is pressed for 3~4 seconds. It returned to the normal condition<br />

Set the D-time<br />

to 10sec<br />

(Set the motor<br />

starting time)<br />

5A setting<br />

T phase current<br />

6. Check the causes of the fault by look at the display unit<br />

The causes of the fault is switched on and off for 0.5sec interval. If you press the “Display”<br />

button at this time, you can see the values and the causes of the fault<br />

ex)<br />

R<br />

S<br />

Turn on<br />

R<br />

S<br />

R<br />

S<br />

T<br />

<strong>Overload</strong><br />

T<br />

Under current<br />

T<br />

Reverse phase<br />

R<br />

S<br />

T<br />

Turn<br />

on & off<br />

R<br />

S<br />

T<br />

R<br />

S<br />

T<br />

Phase fail<br />

R<br />

S<br />

T<br />

Ground fault<br />

R<br />

R<br />

S<br />

S<br />

R<br />

R<br />

T<br />

Stall<br />

T<br />

Short circuit<br />

S<br />

T<br />

S<br />

T<br />

R<br />

S<br />

R<br />

S<br />

T<br />

T<br />

Lock<br />

Zero current sensitivity setting<br />

<br />

<br />

<br />

<br />

<br />

<br />

Sensitivity<br />

DIP S/W<br />

(mA) 1 2 3 4<br />

100<br />

200 1<br />

500 1<br />

1000 1<br />

1500 1<br />

2000 1 1<br />

2500 1 1 1 1<br />

Note) 1. Please use ZCT for LS <strong>EMPR</strong>.<br />

26


Operation and Setting<br />

IMP Series<br />

1. Test/Reset<br />

1) Check wires.<br />

2) Press the Test/Reset key once. Then “TEST”is displayed and the <strong>EMPR</strong> is tripped.<br />

3) Press again the Test/Reset key to reset the <strong>EMPR</strong>.<br />

Note) While the motor is running, the Test/Reset key does not work.<br />

2. Setting<br />

1) Press the Test/Reset key once. Then “TEST”is displayed and the <strong>EMPR</strong> is tripped.<br />

2) Press the Enter key. Then “P-99”is displayed. Use the Up/Down keys to change the password.<br />

3) Press the Enter key to enter A-gr setup mode.<br />

Use the Up/Down keys to select a group and Press the Enter key to enter the selected group.<br />

Press the Test/Reset key to move back to the previous mode.<br />

4) In the A-Grp mode, Press the Enter key. Then “1.CHA”is displayed.<br />

Use the Up/Down keys to select an item and Press the Enter key to enter the selected item.<br />

Press the Test/Reset key to move back to the previous mode.<br />

5) Use the Up/Down keys to set up the value and Press the Enter key to save it.<br />

Note) When the power is supplied first or is resupplied after a power failure, must set up the date in b-gr, 5.S-d.<br />

Set up the rated current S/W while the power is off.<br />

3. Quick Setup<br />

1) Press the “Up and Enter”keys at the same time. “UPLD”is displayed and settings are uploaded<br />

to the display.<br />

2) Insert the display to the body without settings, and then press the Test key to enter the test mode.<br />

3) Press the “Down and Enter”keys at the same time. “TEST”is displayed and downloading is<br />

completed.<br />

4) Press the Test key to return to the normal mode.<br />

Note) Communication settings cannot be uploaded or downloaded.<br />

4. Setting Checkup<br />

1) Press the Enter key.<br />

2) Use the Up/Down keys to select a group and Press the Enter key to enter the selected group.<br />

Press the Test/Reset key to move back to the previous mode.<br />

3) Use the Up/Down keys to select an item and Press the Enter key to enter the selected item.<br />

4) Press the Enter key again to check settings.<br />

5. Failure Event Checkup<br />

1) Press the Up and Down keys at the same time to display “1.O-C”(recent failure events).<br />

Note) When no failure events are stored, “1.non3”is displayed.<br />

2) Use the Up/Down keys to select an event and press the Enter key to go to the selected event.<br />

3) The R-phased failure current is displayed. Every time the Down key is pressed, S-phased failure<br />

current, Tphased failure current, overload rate and date are displayed one after the other.<br />

4) Press the Test/Reset key to move back to the previous mode.<br />

5) Press the Up and Down keys at the same time to get out of the failure event checkup mode.<br />

6. Forced Thermal Reset<br />

When the system is tripped while it is in the thermal inverse time mode, if you want to turn the<br />

<strong>EMPR</strong> into the cold mode by resetting the motor’s heat amount, Press the Enter and Test/Rest<br />

keys at the same time.<br />

* When a trip occurs due to the thermal excess current, if the motor is started right after it is reset, as the motor is<br />

hot, it is highly likely that the motor is tripped again.<br />

27


Electronic motor protection relays<br />

Operation and Setting<br />

IMP Series<br />

Setting Menu (A Group)<br />

Group Menu Setting Value Description Default Value<br />

A<br />

dEF/th/n-th<br />

Operation Characteristics<br />

(Definite/Thermal Inverse/Inverse)<br />

n-th (Inverse)<br />

1~60s Operation Time (sec) 60<br />

1~200s Delay Time (sec) 200<br />

0.5~10A/5~100A Rated Current (10/100A) 10/100A<br />

0.25, 0.5, 1~200 CT Ratio (4 times, twice, once) 1 Note)<br />

OFF, 200~800% Lock Protection (sec) OFF<br />

OFF, 150~500% Stall Protection (sec) OFF<br />

OFF/On Open Phase OFF<br />

OFF, 10~70% Unbalance Protection (%) OFF<br />

OFF/On Reverse Phase OFF<br />

OFF, 30~90% Under Current Protection (%) OFF<br />

0FF, 0.03, 0.05/0.1~3A<br />

Ground Fault Operation Current<br />

(Zero sequence CT)<br />

OFF<br />

OFF, 20~500% (FLCmin)<br />

Ground Fault Operation Current<br />

(Residual circuit)<br />

OFF<br />

0.05, 0.1~1.0s Ground Fault Operation Time -<br />

On/OFF Ground Fault Delay During Start ON<br />

OFF, 500~1000% Instantaneous Protection (%) OFF<br />

I-tp, I-AL, U-C, OrH, ALo AL(07-08) contact setting I-tp<br />

I-tp Instantaneous-current trip and warning -<br />

I-AL Instantaneous-Current warning only -<br />

U-C Under-Current warning only -<br />

OrH Run Time Elapsed warning only -<br />

ALo Activating 18.Ar. Menu -<br />

On, 60~110%/10(%) In case of ALO setting is done not use<br />

On On-load status (I > 0A) signal -<br />

60~110% Over-current waring signal (over the setting value) -<br />

1a1b, 2a, 2b Contact (95-96, 97-98) Setting 1a1b<br />

Note) 1. When the rated current S/W is 100A, the CT ratio is not displayed.<br />

2. Some menus are not displayed if relevant functions are not available.<br />

* Contact operation exemplification (Menu 19. cS)<br />

19.cS<br />

Contact operation<br />

Setting Value<br />

Motor state<br />

Default Value<br />

95-96 97-98<br />

Normal running NC NO<br />

1a1b Ground/Leakage Fault NO NC<br />

Fault operation (except Ground fault) NO NC<br />

Normal running NO NO<br />

2a Ground/Leakage Fault NO NC 1a1b<br />

Fault operation (except Ground fault) NC NO<br />

Normal running NC NC<br />

2b Ground/Leakage Fault NC NO<br />

Fault operation (except Ground fault) NO NC<br />

28


Operation and Setting<br />

IMP Series<br />

Setting Menu (B Group)<br />

Group Menu Setting Value Description Default Value<br />

B On/OFF Electric Reset On<br />

OFF, 1~20 min Automatic Reset OFF<br />

Hour/Minute Run Time Time Check<br />

OFF, 1~8760Hour Run Time Setup (Hour) -<br />

2009/01.01/00:00 YY/MM/DD/ HH:MM (View/Setup) -<br />

Day/hour:minute Total Run Time Time Check<br />

0.5~10/5~100A Analog output A420 Model<br />

1~247 Communication Address<br />

96/192/384 Communication Speed<br />

M485 Model<br />

On/OFF<br />

Operation Display<br />

IMP Specifications for Low Voltage 3-Phase Induction Motors (Reference)<br />

Full Load Current<br />

IMP Settings<br />

Motor Output (Less than kW)<br />

External CT<br />

for the Motor Current Selection S/W Wire Tunnel CT ratio 220V 380V 440V<br />

0.7A or less 4 times 0.25 - 0.1 0.18 0.2<br />

0.7~1.6A 0.5~10A Twice 0.5 - 0.25 0.55 0.6<br />

1.6~8A Once 1 - 1.5 3 3.7<br />

7~100A 5~100A Once 1 - 25 45 55<br />

90~120A Once 30 SCT-150 30 55 55<br />

120A~160A Once 40 SCT-200 45 75 90<br />

160~240A Once 60 SCT-300 55 110 132<br />

240~320A 0.5~10A Once 80 SCT-400 90 160 160<br />

320~400A Once 100 500 : 5 110 200 200<br />

400~480A Once 120 600 : 5 132 250 250<br />

480~640A Once 160 800 : 5 160 320 320<br />

Note) 1. This table is written based on the full load current.<br />

2. The CT is selected as a reference for the <strong>EMPR</strong>’s current setting range.<br />

SWAP<br />

Note) 1. When the power is supplied first or is resupplied after a power failure, must set up the date (5.S-d).<br />

2. Automatic reset is only possible in case of an excess current trip.<br />

Display Description Remark<br />

Over Current Trip<br />

Operate within predefined time.<br />

Under Current Trip<br />

Operate within 3 seconds.<br />

Reverse Phase Current<br />

Unbalance Rate<br />

Current Unit<br />

Open Phase Trip Operate within 1.5 seconds when the unbalance rate is over 70%. R Phase<br />

Unbalance Trip<br />

Operate within 3 seconds.<br />

S Phase<br />

Lock Trip<br />

Operate within 0.5 seconds.<br />

Stall Trip<br />

Operate within 3 seconds.<br />

T Phase<br />

Ground Fault Current<br />

Reverse Phase Trip<br />

Operate within 0.1 second.<br />

Load Rate Unit<br />

Load Rate Display<br />

Ground Fault Trip<br />

Operate within predefined time.<br />

Communication Status<br />

Instantaneous Trip<br />

Operate within 0.05 seconds.<br />

Elapsed Time (No Trip)<br />

The operation time is reset when the Reset key is pressed.<br />

Communication Fault between Body and Display (Press the ENTER/RESET key to return to the normal mode) Note) kW, kVar, and V indicate the specification of the voltage models (under development).<br />

Analog (DC 4~20mA) Output / Communication<br />

1) The biggest current out of measured 3-phase currents is converted into DC 4mA~20mA<br />

and the current measured remotely by digital meter can be displayed.<br />

2) When there is no current, 4mA is sent. If the current goes beyond the predefined value,<br />

20mA is sent.<br />

Output Current = 16mA × Load Current + 4mA (Settings are changed in A.t-d of b-gr)<br />

Setting<br />

3) When the system is the 0.5A~10A setting mode, measurement starts from 0.3A. When<br />

the system is the 5A~100A setting mode, measurement starts from 3A. Thus, when the<br />

current is under 0.3A (3A), 0A is measured and output is 4mA. (To measure the load<br />

current correctly, an appropriate CT should be used).<br />

Note) The allowable burden is less than 500Ϊ .<br />

Considering the receiver resistance (usually 250Ϊ<br />

Communication Spec. :<br />

Refer to 41 page and <strong>LSIS</strong> Homepage (www.lsis.biz)<br />

) and track resistance), the shielding cable should be used.<br />

20mA<br />

20mA<br />

16.8mA<br />

16mA<br />

13.6mA<br />

12mA<br />

8mA<br />

4mA<br />

0A 0.1A 0.2A 0.3A 0.4A 0.5A(0.5A~10A)<br />

0A 1A 2A 3A 4A 5A(5A~100A)<br />

< Analogue output when the output is set to be 0.5A (5A) ><br />

20mA<br />

20mA<br />

16.8mA<br />

16mA<br />

13.6mA<br />

12mA<br />

10.4mA<br />

7.2mA<br />

8mA<br />

4mA<br />

0A 1A 2A 3A 4A 5A(0.5A~10A)<br />

0A 10A 20A 30A 40A 50A(5A~100A)<br />

< Analogue output when the output is set to be 5A (50A) ><br />

29


Electronic motor protection relays<br />

Dimensions<br />

GMP Series<br />

GMP22-2P (1c) Sol<br />

GMP22-2PD (1c) Sol<br />

Screw<br />

Screw<br />

0.15kg<br />

GMP22-2P (1a1b) Sol<br />

GMP22-3P Sol<br />

GMP22-2PA (1a1b) Sol<br />

GMP22-3PR Sol<br />

Screw<br />

Screw<br />

0.18kg<br />

GMP40-2P Sol<br />

GMP40-2PD Sol<br />

GMP40-2PA Sol<br />

GMP40-3P Sol<br />

GMP40-3PR Sol<br />

Screw<br />

Screw<br />

0.20kg/0.22kg<br />

GMP80-2S<br />

GMP80-3S<br />

GMP80-3SR<br />

Screw<br />

Mounting hole<br />

Screw<br />

30<br />

0.42kg/0.46kg


Dimensions<br />

GMP Series<br />

GMP22-2S<br />

GMP22-3S<br />

GMP22-3SR<br />

GMP40-2S<br />

GMP40-3S<br />

GMP40-3SR<br />

Screw<br />

Screw<br />

0.19kg/0.21kg<br />

GMP22-2T<br />

GMP22-3T<br />

GMP22-3TR<br />

GMP40-2T<br />

GMP40-3T<br />

GMP40-3TR<br />

Screw<br />

0.14kg/0.16kg<br />

GMP60T<br />

GMP60TE<br />

GMP60TA<br />

Screw<br />

Screw<br />

0.14kg<br />

31


Electronic motor protection relays<br />

Dimensions<br />

GMP Series<br />

GMP60-TD<br />

GMP60-TDa<br />

26.8<br />

62.25<br />

R2.5<br />

7.2 8.2<br />

74<br />

R2.5<br />

10<br />

61<br />

75<br />

22±0.5<br />

74<br />

12.5<br />

55.4<br />

5.8<br />

55.4<br />

72.8<br />

47<br />

0.25kg<br />

GMP60-3TZ, TZR<br />

GMP60-3TN, TNR<br />

GMP60-3T, TR<br />

Tunnel type<br />

Screw type - Terminal lug sticking<br />

Terminal arrangement<br />

GMP22-2P (1c)<br />

GMP22-2PD (1c)<br />

GMP22-2PA (1c)<br />

GMP22-2P (1a1b)<br />

GMP22-3P<br />

GMP40-2P/3P<br />

GMP22-2/3S<br />

GMP40-3/3S<br />

GMP80-2/3S<br />

Note)<br />

GMP22-2/3T<br />

GMP40-2/3T<br />

GMP60-T/TE/TA<br />

Note) 1. Only for the GMP60-TZR modle.<br />

2. Aux. Contacts are operate when power applied.<br />

GMP60-TD<br />

GMP60-TDa<br />

GMP60-3TZ, TZR<br />

GMP60-3TN, TNR<br />

GMP60-3T/3TR<br />

32


Dimensions<br />

DMP Series<br />

DMP-S<br />

DMP-SZ<br />

DMP-Sa<br />

DMP-SZa<br />

※Aux. contact wire size<br />

: below 8[mm 2 ]<br />

※Torque : 0.5N<br />

Mounting dimensions<br />

0.7kg<br />

DMP-S<br />

DMP-SZ<br />

DMP-Sa<br />

DMP-SZa<br />

Mounting dimensions<br />

Panel mounting<br />

0.64kg<br />

Panel cutting size<br />

Note) 1. In extension type, the digital <strong>EMPR</strong> is calibrated with combining the display unit and mainbody<br />

so, please cautious not to combine the display unit and mainbody with different part No.<br />

2. The 07-08 contacts are the ZCT input terminal (Digital <strong>EMPR</strong> with ground fault function)<br />

33


Electronic motor protection relays<br />

Dimensions<br />

DMP Series<br />

DMP-T<br />

DMP-TZ<br />

DMP-Ta<br />

DMP-TZa<br />

※Wire size to penetrate a CT<br />

:below 22[mm 2 ]<br />

Mounting dimensions<br />

0.56kg<br />

DMP-T<br />

DMP-TZ<br />

DMP-Ta<br />

DMP-TZa<br />

Mounting dimensions<br />

Panel mounting<br />

0.5kg<br />

Panel cutting size<br />

34<br />

Note) 1. In extension type, the digital <strong>EMPR</strong> is calibrated with combining the display unit and mainbody<br />

so, please cautious not to combine the display unit and mainbody with different part No.<br />

2. The 07-08 contacts are the ZCT input terminal (Digital <strong>EMPR</strong> with ground fault function)


Dimensions<br />

IMP Series<br />

One-Body Type<br />

Separate BOdy Type<br />

90<br />

68<br />

64<br />

U/2/T1 V/4/T2 W/6/T3<br />

109.3<br />

∅17<br />

21<br />

17 56<br />

17<br />

26 44<br />

20 22<br />

64<br />

5<br />

12<br />

82<br />

121.3<br />

4.2<br />

25<br />

53.5<br />

Panel mounting<br />

M4<br />

22<br />

90<br />

Note) The cable should be purchased separately (1m/1.5m/2m/3m).<br />

35


Electronic motor protection relays<br />

Wiring method<br />

GMP Series<br />

GMP22-2P (1c)<br />

GMP60T (1c)<br />

GMP22-2P 1c(N)<br />

GMP60T 1c(N)<br />

GMP22-2P 1c(R)<br />

GMP60T 1c(R)<br />

Note) 1c(N) Type: Fail-safe operation(No volt release) contact type (When power applied the Aux. contact operate)<br />

1c(R) Type: Non-fail-safe operation contact type<br />

GMP- (1a1b)<br />

With the External CT<br />

GMP60-3TZ, TZR<br />

GMP60-3TN, TNR<br />

GMP60-3T, 3TR<br />

주)<br />

36<br />

Note) 1. The Z1, Z2 are the ZCT input terminal (GPM60-3TZ/TZ type)<br />

2. Aux. contacts are operate when power applied.


Wiring method<br />

DMP Series<br />

DMP-S/Sa<br />

DMP-T/Ta<br />

With the External CT<br />

Single phase<br />

Note) When the single-phase motor is used, reverse phases protection should be set off.<br />

DMP-SZ/SZa<br />

DMP-TZ/TZa<br />

95 97<br />

96 98<br />

(2a)<br />

(1a1b)<br />

(2b)<br />

DMP-SI/TI<br />

DMP-TZ/TZa<br />

MCCB<br />

AUX<br />

MC<br />

MCCB<br />

SHUNT<br />

95 97 07<br />

STOP<br />

RUN<br />

SR<br />

96 98 08<br />

37


(+) (-)<br />

ZCT<br />

(+) (-)<br />

ZCT<br />

Electronic motor protection relays<br />

Wiring method<br />

IMP Series<br />

OFF<br />

(RESET)<br />

OL<br />

TRIP<br />

Y<br />

MCCB<br />

AUX<br />

MC<br />

SHT MCCB<br />

MC<br />

RS485<br />

(4~20mA)<br />

VR VS VT<br />

TRX(+) TRX(-) 05 06<br />

10A<br />

VR VS VT<br />

TRX(+) TRX(-) 05 06<br />

100A<br />

10A<br />

100A<br />

A1 A2 95 97 07<br />

TRX (+, -)<br />

A1 A2 95 96<br />

97 98 07 08 Z1 Z2<br />

A1 A2 95 96 97 98 07 08 Z1 Z2<br />

<strong>EMPR</strong><br />

OL<br />

SR<br />

96 98 08 Z1 Z2<br />

ZCT<br />

Note 1)<br />

With the External CT<br />

Note) 1. When the zero-phase-sequence current transformer is used to detect ground faults, connect the ZCT.<br />

2. When the single-phase motor is used, all phases are connected except the S phase, and open-phase, unbalance and ground fault should be set OFF.<br />

Terminal layout<br />

VR VS VT TRX(+) TRX(-) 05 06<br />

10A<br />

100A<br />

A1(+) A2(-)<br />

95 96 97 98 07 08 Z1 ZCTZ2<br />

Communication specification<br />

- Operation mode: Differential<br />

- Distance: Max. 1.2km<br />

- General RS-485 shielded twist 2-pair cable<br />

- Baud rate: 9600/19200/38400bps<br />

- Transmission method: half-Duplex<br />

- Max. In/Output voltage: -7V~+12V<br />

Terminal Configuration<br />

Engrave Description Remark<br />

A1(+), A2(-) Input terminal for operation power AC/DC 85~245V, AC/DC 24~36V<br />

95-96 When the power is ON (NC contact output) In case of an instantaneous trip, if 17.lo is ALT, it is NC, and if 17.lo is Trip, it is NO.<br />

97-98 When the power is ON (NC contact output) In case of an instantaneous trip, regardless of 17 .1o setup, it is NC.<br />

07-08 Converted to the NC mode only when an instantaneous trip occurs.<br />

Z1, Z2 Output terminal for the zero-phase sequence current transformer Specific ZCT (for the <strong>EMPR</strong>)<br />

TRX(+)<br />

RS485 terminal (TRX+) Or 4~20mA (+) output<br />

M485, A420 Type<br />

TRX(-)<br />

RS485 terminal (TRX-) Or 4~20mA (-) output<br />

10A/100A Max. rated current change S/W 10A : 0.5~10A, 100A : 5~100A<br />

VR/VS/VT<br />

3-phase voltage input terminal<br />

N/A<br />

05-06 Output terminal for voltage protection<br />

Note) 1. The 3-phase voltage input terminal and 05-06 output terminal should be connected only for voltage protection models, which will be released in the future.<br />

2. For RS485 connection, the terminal resistance should be 120Ϊ .<br />

3. For 4~20mA current, the maximum burden should be less than 500Ϊ .<br />

38


Accessories<br />

CT, ZCT, Cable and Terminal<br />

Specification<br />

Type Model Primary current Secondary Burden(VA) Tunnel hole [mm] Front mounting <strong>EMPR</strong> Remarks<br />

3CT-23 80, 100, 150, 180, 200A 21×21 GMP22/40/60T<br />

3CT type 3CT-43<br />

100, 150, 200, 250, 300,<br />

DMP/IMP series<br />

5A 1.5 27×27<br />

350, 400A GMP60-3T/3TN/3TZ 1) Class: 1.0<br />

3CT-63 400, 500, 600A 45×30 GMP22/40/60T<br />

2) Insulation voltage: 690V<br />

DCT-100 100A<br />

3) Withstand voltage:<br />

DCT-150 150A<br />

4kV/Imin<br />

2CT type DCT-200 200A 5A 5 28.5×33.5 GMP22/40/60T<br />

4) Overcurrent strength:<br />

DCT-300 300A<br />

40×In<br />

DCT-400 400A<br />

5) Insulation Resistance:<br />

SCT-100 100A<br />

10MΩ<br />

SCT-150 150A DMP/IMP series<br />

(DC 500V Megger)<br />

1CT type SCT-200 200A 5A 5 27.5×32.5 GMP60-3T/3TN/3TZ 6) Frequency: 50/60Hz<br />

SCT-300 300A GMP22/40/60T<br />

SCT-400 400A<br />

* Ref. When secondary cable is 2.5mm 2 , 3m length burden is 0.52VA.<br />

3CT<br />

E<br />

5<br />

A<br />

B<br />

w<br />

Kw<br />

C<br />

Kv<br />

Ku<br />

u<br />

구분<br />

A<br />

B<br />

C<br />

D<br />

E<br />

F<br />

3CT-23<br />

119<br />

35<br />

9<br />

21.5<br />

89<br />

78<br />

3CT-43<br />

149<br />

44<br />

11<br />

27<br />

117<br />

93<br />

3CT-63<br />

218<br />

70<br />

20<br />

45/30<br />

183<br />

96<br />

DCT<br />

65<br />

33.5<br />

28.5<br />

55<br />

120<br />

60<br />

80<br />

69.6<br />

53<br />

62<br />

B<br />

D<br />

D<br />

F<br />

2- 5<br />

SCT<br />

Combination of 3 SCTs<br />

39


Electronic motor protection relays<br />

Accessories<br />

CT, ZCT, Cable and Terminal<br />

Ratings<br />

ZCT (Zero Sequence CT)<br />

Type Diameter (A) Ratio Weight (kg) Model<br />

ZCT, D30 30 0.5 LZT-030<br />

ZCT, D50 50 100mA/40~55mV 0.7 LZT-050<br />

ZCT, D65 65 200mA/100mV 0.9 LZT-065<br />

ZCT, D80 80 1.5 LZT-080<br />

Dimension<br />

ZCT 30<br />

ZCT 50, 65, 80<br />

Unit (mm)<br />

Model A B C D E F G H I ∅<br />

LZT-030 30 25 108 100 114 7 32 32 110 6<br />

∅<br />

Unit (mm)<br />

Model A B C D E F G H I<br />

LZT-050 50 25 131 100 122 7 32 36 114 6<br />

LZT-065 65 26 143 114 133 7 39 37 126 6<br />

LZT-080 80 34 174 160 180 7 40 40 151 6<br />

Other Options<br />

Cable<br />

Terminal Block<br />

Applicable Type<br />

DMP, IMP Series<br />

Applicable Type<br />

DMP Series, GMP60-3T, 3TZ, 3TN<br />

Spec.<br />

1m, 1.5m, 2m, 3m, 4m<br />

Spec.<br />

60A blelow<br />

* Panel mount: Extension cable<br />

40


<strong>EMPR</strong> Curves<br />

<br />

<br />

<br />

<br />

<br />

<br />

41


Electronic motor protection relays<br />

Direct mounting <strong>EMPR</strong> new/old comparative table<br />

Wiring/Mounting Compatibity Note) NO NO NO<br />

GMP22-2P (1c) GMP22-2P GMP22-3P GMP40-2P GMP40-3P<br />

Type<br />

GMP22-2PD (1c) GMP22-2PA GMP22-3PR GMP40-2PD GMP40-3PR<br />

GMP40-2PA<br />

Number of sensors 2 2 3 2 3<br />

Over current<br />

Protective<br />

Phase failure<br />

Locked rotor<br />

function<br />

Phase unbalance<br />

Reverse phase<br />

(PR)<br />

(PR)<br />

Aux. contact (at Energization) 1SPDT (1c) 2SPST (1a1b) 2SPST (1a1b)<br />

Rating Current 0.3~1.5, 1~5, 4.4~22A 0.3~1.5, 1~5, 4.4~22A 4~20, 8~40A<br />

Metasol<br />

(New)<br />

<strong>EMPR</strong><br />

Demension<br />

Type of contactors MC-9b, 12b, 18b, 22b MC-9b, 12b, 18b, 22b MC-32a, 40a<br />

Meta-MEC<br />

(Old)<br />

<strong>EMPR</strong><br />

Demension<br />

Type of contactors GMC-9, 12, 18, 22 GMC-9, 12, 18, 22 GMC-32, 40<br />

GMP60T (1c) GMP22-2T GMP22-3T GMP40-2T GMP40-3T<br />

Retrofit Type (Tunnel) GMP22-2T GMP60TA (1c) GMP22-3TR GMP60T (1c) GMP40-3TR<br />

Note) If you want to use Metasol <strong>EMPR</strong> with GMC <strong>Contactor</strong>s, only tunnel type <strong>EMPR</strong> is avaliable.<br />

GMP60TA (1c)<br />

42


Certificates<br />

A Species of Certification<br />

Approvals<br />

Certificates<br />

A Species of Standard<br />

Safety certi<br />

IEC<br />

UL<br />

GB<br />

Gosstandart<br />

IEC<br />

Mark or<br />

certification<br />

Type<br />

<strong>EMPR</strong><br />

DMPR<br />

IMP<br />

GMP22-2P<br />

GMP22-3P<br />

GMP22-3PR<br />

GMP22-2S<br />

GMP22-3S<br />

GMP22-3SR<br />

GMP22-2T<br />

GMP22-3T<br />

GMP22-3TR<br />

GMP40-2P<br />

GMP40-3P<br />

GMP40-3PR<br />

GMP40-2S<br />

GMP40-3S<br />

GMP40-3SR<br />

GMP40-2T<br />

GMP40-3T<br />

GMP40-3TR<br />

GMP60-T<br />

GMP60-TE<br />

GMP80-2S<br />

GMP80-3S<br />

GMP80-3SR<br />

DMP06,60-S<br />

DMP06,60-Sa<br />

DMP06,60-T<br />

DMP06,60-Ta<br />

DMP06,60-SI<br />

DMP06,60-SZ<br />

DMP06,60-Sza<br />

DMP06,60-TZ<br />

DMP06,60-Tza<br />

DMP06,60-TI<br />

IMP-C-NO<br />

IMP-C-A420<br />

IMP-C-A485<br />

S-Mark<br />

Korea<br />

CE<br />

Europe<br />

cUL<br />

U.S.A/Canada<br />

CCC<br />

China<br />

GOST<br />

Russia<br />

KEMA<br />

Netherlands<br />

● ● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ● ● ●<br />

● ● ● ● ●<br />

● ● ● ● ●<br />

● ● ● ● ●<br />

● ● ● ● ●<br />

● ● ● ● ●<br />

● ● ● ● ●<br />

●<br />

● ● ● ● ●<br />

●<br />

● ● ● ● ●<br />

● ● ● ● ●<br />

●<br />

● ● ● ● ●<br />

●<br />

● ● ● ● ●<br />

●<br />

●<br />

●<br />

A Species of Certification<br />

A Species of Standard<br />

Approvals<br />

Marine classiflcation<br />

Mark or<br />

certification<br />

1867<br />

Type<br />

KR<br />

Korea<br />

LR<br />

U.K<br />

BV<br />

France<br />

ABS<br />

U.S.A<br />

GL<br />

Germany<br />

DNV<br />

Norway<br />

RINA<br />

Italy<br />

DMPR<br />

DMP06,36,60-S<br />

DMP06,36,60-Sa<br />

DMP06,36,60-T<br />

DMP06,36,60-Ta<br />

DMP06,36,60-SI<br />

DMP06,36,60-SZ<br />

DMP06,36,60-Sza<br />

DMP06,36,60-TZ<br />

DMP06,36,60-Tza<br />

DMP06,36,60-TI<br />

● ● ●<br />

● ● ●<br />

● ● ●<br />

● ● ●<br />

● ● ●<br />

● ● ●<br />

● ● ●<br />

● ● ●<br />

● ● ●<br />

● ● ●<br />

43


Safety Instructions<br />

For your safety, please read user's manual thoroughly before operating.<br />

Contact the nearest authorized service facility for examination, repair, or adjustment.<br />

Please contact a qualified service technician when you need maintenance.<br />

Do not disassemble or repair by yourself!<br />

Any maintenance and inspection shall be performed by the personnel having expertise concerned.<br />

c 2012.6 <strong>LSIS</strong> Co.,Ltd. All rights reserved.<br />

www.lsis.com<br />

HEAD OFFICE<br />

LS-ro 127 (Hogye-dong) Dongan-gu Anyang-si<br />

Gyeonggi-do Korea<br />

Tel. (82-2)2034-4840, 4911, 4914<br />

Fax. (82-2)2034-4648<br />

CHEONG-JU PLANT<br />

Cheong-Ju Plant #1, 95 Baekbong-ro Heungdeok-gu<br />

Cheongju-si Chungcheongbuk-do 361-720 Korea<br />

Specifications in this catalog are subject to change without notice due to<br />

continuous product development and improvement.<br />

Global Network<br />

<strong>LSIS</strong> USA Inc. Chicago, America<br />

Address: 2000 Millbrook Drive, Lincolnshire, Chicago, IL 60069, United States of America<br />

Tel: 847-941-8240 Fax: 847-941-8259 e-mail: seungheonc@lsis.com<br />

<strong>LSIS</strong> (Middle East) FZE Dubai, U.A.E.<br />

Address: LOB 19 JAFZA VIEW TOWER Room 205, Jebel Ali Freezone P.O. Box 114216, Dubai, United Arab Emirates<br />

Tel: 971 4 886 5360 Fax: 971 4 886 5361 e mail: hschoib@lsis com<br />

<strong>LSIS</strong> Europe B.V. Schiphol-Rijk, Netherlands<br />

Address: 1st. Floor, Tupolevlaan 48, 1119NZ,Schiphol-Rijk, The Netherlands<br />

Tel: 31-20-654-1420 Fax: 31-20-654-1429 e-mail: junshickp@lsis.biz<br />

<strong>LSIS</strong>-VINA Co., Ltd. Hanoi, Vietnam<br />

Address: Nguyen Khe - Dong Anh - Ha Noi - Viet Nam<br />

Tel: 84-4-882-0222 Fax: 84-4-882-0220 e-mail: sjbaik@lsis.biz<br />

<strong>LSIS</strong>-VINA Co., Ltd. Hochiminh, Vietnam<br />

<strong>LSIS</strong> Address: 41 Nguyen Thi Minh Khai Str. Yoco Bldg 4th Floor, Hochiminh City, Vietnam<br />

Tel: 84-8-3822-7941 Fax: 84-8-3822-7942 e-mail: hjchoid@lsis.biz<br />

<strong>LSIS</strong> Gurgaon Office Gurgaon, India<br />

Address: 109 First Floor, Park Central, Sector-30, Gurgaon- 122 002, Haryana, India<br />

Tel: +0091-124-493-0070 Fax: 91-1244-930-066 e-mail: hwyim@lsis.biz<br />

<strong>LSIS</strong> Japan Co., Ltd. Tokyo, Japan<br />

Address: Toykokurakubu Bldg. 13th floor, 3-2-6, Kasumigaseki, Chiyoda-ku, Tokyo, 100-0013 Japan<br />

TEL:+81-3-6268-8241 FAX:+81-3-6268-8240 e-mail: jschuna@lsis.biz<br />

<strong>LSIS</strong> Shanghai Office Shanghai, China<br />

Address: Room 32 floors of the Great Wall Building, No. 3000 North Zhongshan Road, Putuo District, Shanghai, China<br />

Tel: 86-21-5237-9977 Fax: 89-21-5237-7189 e-mail: mkleea@lsis.com<br />

<strong>LSIS</strong> Beijing Office Beijing, China<br />

Address: B-Tower 17FL.Beijing Global Trade Center B/D. No.36, BeiSanHuanDong-Lu, DongCheng-District, Beijing<br />

100013, P.R. China<br />

Tel: 86-10-5825-6025,7 Fax: 86-10-5825-6026 e-mail: sunmj@lsis.com.cn<br />

<strong>LSIS</strong> Guangzhou Office Guangzhou, China<br />

Address: Room 1403, 14/F, New Poly Tower, No.2 Zhongshan Liu Road, Guangzhou 510180, P.R. China<br />

Tel: 020-8326-6754 Fax: 020-8326-6287 e-mail: chenxs@lsis.com.cn<br />

<strong>LSIS</strong> Chengdu Office Chengdu, China<br />

Address: Room 1701 17Floor, huamin hanjun internationnal Building, No1 Fuxing Road Chengdu, 610016, P.R. China<br />

Tel: 86-28-8670-3201 Fax: 86-28-8670-3203 e-mail: yangcf@lsis.com.cn<br />

<strong>LSIS</strong> Qingdao Office Qingdao, China<br />

Address: Room 2001,20/F,7B40, Galaxy Building, No.29 Shandong Road, Shinan District, Qingdao 266071, P.R. China<br />

Tel: 86-532-8501-6058 Fax: 86-532-8501-6057 e-mail: htroh@lsis.biz<br />

<strong>LSIS</strong> (Wuxi) Co., Ltd. Wuxi, China<br />

Address: 102-A , National High & New Tech Industrial Development Area, Wuxi, Jiangsu, 214028, P.R.China<br />

Tel: 86-510-8534-6666 Fax: 86-510-522-4078 e-mail: wangzy@lsis.com.cn<br />

Dalian <strong>LSIS</strong> Co., Ltd. Dalian, China<br />

Address: No.15, Liaohexi 3-Road, Economic and Technical Development zone, Dalian 116600, China<br />

Tel: 86-411-8273-7777 Fax: 86-411-8730-7560 e-mail: tangyh@lsis.com.cn<br />

2014. 06 Metasol <strong>EMPR</strong> (E) 2012. 06/(05) 2014. 06 Printed in Korea STAFF


Meta-MEC<br />

Manual Motor Starters


Manual Motor Starters<br />

LS Meta-MEC Manual Motor Starters provide<br />

completed ranges up to 100A<br />

45 mm<br />

55 mm<br />

32AF<br />

2 2


45 mm<br />

70 mm<br />

63AF<br />

100AF<br />

3 3


Manual LS Meta-MEC Motor Starters Manual Motor Starters deliver<br />

more efficiency through various functions<br />

and compact design<br />

Finger safe terminals<br />

Front mounted auxiliary<br />

contact<br />

Easy mounting onto DIN-rails<br />

Dial cover<br />

Large scale for current setting<br />

Auxiliaries are just snapped on:<br />

easy, fast, without tools<br />

Handle Lock device(Off position)<br />

Dial cover lock device<br />

Test trip device for checks of the<br />

trip mechanism<br />

Three position operator handle:<br />

ON-OFF-TRIP<br />

(Only 100AF is applied)<br />

Identification labels<br />

45 mm<br />

Handle Lock Dial cover Terminals<br />

<strong>MMS</strong>-32 <strong>MMS</strong>-63 <strong>MMS</strong>-100<br />

Screw Lug Lug<br />

4 4


Common use from 32 to 100AF<br />

A wide variety of accessories enables a<br />

flexible response to changes in specifications<br />

Front mounting<br />

auxiliary switch<br />

(FX)<br />

Dial cover<br />

Side<br />

mounting<br />

auxiliary<br />

switch<br />

(LX)<br />

(LX)<br />

Side mounting<br />

Shunt release<br />

(RS)<br />

Side<br />

mounting<br />

auxiliary<br />

switch<br />

(LX)<br />

Side<br />

mounting<br />

alarm<br />

switch<br />

(Any time)<br />

(LA)<br />

Side mounting<br />

Undervoltage<br />

release<br />

(RU)<br />

Side<br />

mounting<br />

alarm<br />

switch<br />

(LX)<br />

Side mounting<br />

alarm switch<br />

(Instantaneous)<br />

(LAM)<br />

Side mounting<br />

Undervoltage<br />

release with<br />

Switch<br />

(RUX)<br />

Direct adaptor<br />

(Mini-MC)<br />

Direct adaptor<br />

(Metasol/Susol-MC)<br />

Mini-MC (9~16A)<br />

Metasol : MC-6a~100a<br />

Susol-MC : 9~95<br />

5 5


Manual Motor Starters<br />

Function<br />

● Protection of group installation<br />

● Protection of circuits<br />

● Motor protection<br />

● Starter protection<br />

● Wide range of ambient<br />

temperature compensation<br />

● Phase failure protection<br />

Feature<br />

● 45mm width up to 32A, 55mm width up to<br />

63A and 70mm width rated to 100amps<br />

● Three position operator :<br />

ON-OFF-TRIP (Only 100AF is applied)<br />

● Complete range of common accessories<br />

● Handle lock in the OFF position<br />

Standard<br />

● Comply with the specifications in accordance with<br />

IEC 60947-2 & IEC 60947-4-1<br />

UL508 (Manual motor controller)<br />

UL508 (Combination motor controller type E starter)<br />

CSA C22.2 NO.14<br />

GB14048<br />

● Class 10 overload trip characteristics<br />

● Trip test<br />

● Finger safe terminal<br />

● Din rail & Screw mounting<br />

Certification<br />

● KEMA CB type certificate<br />

● EC-Declaration of conformity<br />

● UL listed<br />

● CSA certified<br />

● CCC<br />

6 6


Contents<br />

Product Selection Guide<br />

Quick selection table ... IEC rating<br />

Standard type<br />

High breaking type<br />

Instantaneous type<br />

Accessories<br />

8<br />

10<br />

11<br />

12<br />

13<br />

Technical Information<br />

General data<br />

IEC performance data (Motor protection)<br />

Manual motor controller<br />

(UL 508, CSA C22.2 as Manual motor controllers)<br />

Manual Motor Controller (UL508)<br />

Type '2' coordination according to IEC 947-4-1<br />

Time/Current characteristic<br />

Thermal limit on short circuit for <strong>MMS</strong><br />

Dimensions<br />

18<br />

27<br />

31<br />

33<br />

35<br />

36<br />

37<br />

40<br />

7 7


Manual Motor Starters<br />

Product Selection Guide<br />

Quick selection table ... IEC rating<br />

Frame<br />

32AF<br />

Type<br />

Current adjustable type <strong>MMS</strong>-32S <strong>MMS</strong>-32H<br />

Instantaneous type - <strong>MMS</strong>-32HI<br />

Breaking capacity Standard High breaking<br />

Handle Type Toggle Rotary<br />

Number of poles 3 3<br />

Rated operational voltage (Ue) Up to 690V Up to 690V<br />

Rated frequency 50/60 Hz 50/60 Hz<br />

Rated insulation voltage (Ui) 690V 690V<br />

Rated impulse voltage (Uimp) 6kV 6kV<br />

Utilization category IEC 60 947-2 (Breaker) Cat. A Cat. A<br />

IEC 60 947-4 (Motor starter) AC 3 AC 3<br />

Mechanical endurance (Operating) 100,000 100,000<br />

Electrical endurance (Cycles) 100,000 100,000<br />

Max operating frequency per hour (Ope./h) 25 25<br />

Temperature compensation (Operation) -20 ~ +60℃ -20 ~ +60℃<br />

Instantaneous short circuit release 13 × Ie max. 13 × Ie max.<br />

<strong>Overload</strong> protection ◦ ◦<br />

Phase failure function ◦ ◦<br />

Trip indicating function × ×<br />

Test function ◦ ◦<br />

Weight (g) 320 360<br />

Rated<br />

Rated operational<br />

Thermal release 220V<br />

220V<br />

415V 460V 525V 690V<br />

415V 460V 525V 690V<br />

breaking<br />

Adjustment 240V<br />

240V<br />

current (Ie)<br />

400V 440V 500V 600V<br />

400V 440V 500V 600V<br />

capacity<br />

range (A) 230V<br />

230V<br />

(kA)<br />

Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics<br />

0.16<br />

0.25<br />

0.4<br />

0.63<br />

1<br />

0.1~0.16<br />

0.16~0.25<br />

0.25~0.4<br />

0.4~0.63<br />

0.63~1<br />

100 100 100 100 100 100 100 100 100 100<br />

100 100 100 100 100 100 100 100 100 100<br />

100 100 100 100 100 100 100 100 100 100<br />

100 100 100 100 100 100 100 100 100 100<br />

100 100 100 100 100 100 100 100 100 100<br />

100 100 100 100 100 100 100 100 100 100<br />

100 100 100 100 100 100 100 100 100 100<br />

100 100 100 100 100 100 100 100 100 100<br />

100 100 100 100 100 100 100 100 100 100<br />

100 100 100 100 100 100 100 100 100 100<br />

1.6<br />

1~1.6 100 100 100 100 100 100 100 100 3 3 100 100 100 100 100 100 100 100 100 100<br />

2.5<br />

1.6~2.5 100 100 100 100 100 100 50 38 3 3 100 100 100 100 100 100 100 100 8 8<br />

4<br />

2.5~4 100 100 100 100 50 38 15 11 3 3 100 100 100 100 100 100 100 100 8 8<br />

6<br />

4~6 100 100 100 100 15 11 10 8 3 3 100 100 100 100 100 100 100 100 6 6<br />

8<br />

5~8 100 100 100 100 15 11 10 8 3 3 100 100 100 100 50 38 50 38 6 6<br />

10<br />

6~10 100 100 50 38 15 11 6 5 3 3 100 100 100 100 50 38 50 38 6 6<br />

13<br />

9~13 100 100 50 38 10 8 6 5 3 3 100 100 100 100 50 38 42 32 6 6<br />

17<br />

11~17 50 38 20 15 10 8 6 5 3 3 100 100 50 38 20 15 10 8 4 4<br />

22<br />

14~22 40 30 15 11 8 6 6 5 3 3 100 100 50 38 20 15 10 8 4 4<br />

26<br />

18~26 40 30 15 11 8 6 5 4 3 3 100 100 50 38 20 15 10 8 4 4<br />

32<br />

22~32 30 22 15 11 6 4 5 4 3 3 100 100 50 38 20 15 10 8 4 4<br />

40<br />

28~40 20 15 10 8 5 3 4 3 2 2 100 100 40 30 15 11 8 6 3 3<br />

50<br />

34~50 - - - - - - - - - - - - - - - - - - - -<br />

63<br />

45~63 - - - - - - - - - - - - - - - - - - - -<br />

65<br />

47~65 - - - - - - - - - - - - - - - - - - - -<br />

75<br />

55~75 - - - - - - - - - - - - - - - - - - - -<br />

90<br />

70~90 - - - - - - - - - - - - - - - - - - - -<br />

100<br />

80~100 - - - - - - - - - - - - - - - - - - - -<br />

8


63AF<br />

100AF<br />

<strong>MMS</strong>-63S <strong>MMS</strong>-63H <strong>MMS</strong>-100S <strong>MMS</strong>-100H<br />

- <strong>MMS</strong>-63HI - <strong>MMS</strong>-100HI<br />

Standard High breaking Standard High breaking<br />

Rotary Rotary Rotary Rotary<br />

3 3 3 3<br />

Up to 690V Up to 690V Up to 690V Up to 690V<br />

50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz<br />

1,000V 1,000V 1,000V 1,000V<br />

8kV 8kV 8kV 8kV<br />

Cat. A Cat. A Cat. A Cat. A<br />

AC 3 AC 3 AC 3 AC 3<br />

50,000 50,000 50,000 50,000<br />

25,000 25,000 25,000 25,000<br />

25 25 25 25<br />

-20 ~ +60℃ -20 ~ +60℃ -20 ~ +60℃ -20 ~ +60℃<br />

13 × Ie max. 13 × Ie max. 13 × Ie max. 13 × Ie max.<br />

◦ ◦ ◦ ◦<br />

◦ ◦ ◦ ◦<br />

× × ◦ ◦<br />

◦ ◦ ◦ ◦<br />

1,000 1,000 2,200 2,200<br />

220V<br />

220V<br />

415V 460V 525V 690V<br />

240V<br />

240V<br />

400V 440V 500V 600V<br />

230V 230V<br />

Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

100 100 100 100 15 12 10 8 4 3<br />

100 100 50 38 10 8 6 5 4 3<br />

100 100 25 19 10 8 6 5 4 3<br />

50 38 25 19 10 8 6 5 4 3<br />

50 38 25 19 10 8 6 5 4 3<br />

50 38 25 19 10 8 6 5 4 3<br />

50 38 25 19 10 8 6 5 4 3<br />

50 38 25 19 10 8 6 5 4 3<br />

50 38 25 19 10 8 6 5 4 3<br />

50 38 25 19 10 8 6 5 4 3<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

415V 460V 525V 690V<br />

400V 440V 500V 600V<br />

Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

100 100 100 100 50 38 50 38 6 5<br />

100 100 100 100 50 38 42 32 6 5<br />

100 100 50 50 50 38 12 9 5 5<br />

100 100 50 50 50 38 12 9 5 5<br />

100 100 50 50 35 27 12 9 5 5<br />

100 100 50 50 35 27 10 8 5 5<br />

100 100 50 50 35 27 10 8 5 5<br />

100 100 50 50 35 27 10 8 5 5<br />

100 100 50 50 35 27 10 8 5 5<br />

75 50 35 27 25 19 6 5 3 3<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

220V<br />

220V<br />

415V 460V 525V 690V 415V 460V 525V 690V<br />

240V 240V<br />

400V 440V 500V 600V 400V 440V 500V 600V<br />

230V 230V<br />

Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

100 100 50 38 40 30 25 19 10 8<br />

100 100 50 38 40 30 25 19 10 8<br />

100 100 50 38 40 30 25 19 10 8<br />

100 100 50 38 40 30 15 11 10 8<br />

100 100 50 38 40 30 15 11 6 5<br />

100 100 50 38 40 30 12 9 6 5<br />

100 100 50 38 40 30 12 9 6 5<br />

- - - - - - - - - -<br />

100 100 50 38 40 30 8 6 5 4<br />

100 100 50 38 40 30 8 6 5 4<br />

100 100 50 38 40 30 8 6 5 4<br />

Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

- - - - - - - - - -<br />

100 100 100 100 50 38 35 27 12 9<br />

100 100 100 50 50 38 35 27 12 9<br />

100 100 100 50 50 38 35 27 12 9<br />

100 100 100 50 50 38 25 19 12 9<br />

100 100 100 50 50 38 20 15 12 9<br />

100 100 100 50 50 38 15 11 10 8<br />

100 100 100 50 50 38 15 11 8 6<br />

- - - - - - - - - -<br />

100 100 75 50 50 38 12 9 6 6<br />

100 100 75 50 50 38 12 9 6 6<br />

100 100 75 50 50 38 12 9 6 6<br />

9


Manual Motor Starters<br />

Product Selection Guide<br />

Standard type<br />

·Adjustable thermal release<br />

·Magnetic release 13 Ie max.<br />

·Trip class 10<br />

·Protective function<br />

·Phase-failure protection<br />

- phase-failure<br />

- short circuit<br />

- overload<br />

<strong>MMS</strong>-32S <strong>MMS</strong>-63S <strong>MMS</strong>-100S<br />

Type<br />

<strong>MMS</strong>-32S<br />

<strong>MMS</strong>-63S<br />

<strong>MMS</strong>-100S<br />

Rated Thermal Magnetic Switching of 3 phase AC motors, AC-2, AC-3<br />

operational release release 3-phase [kW] (50/60Hz) 3-phase [HP] (60Hz)<br />

400/415V<br />

current Adjustment Operating<br />

Icu Ics<br />

Ie range current 230V 400V 690V 230V 460V 575V<br />

[kA] [kA]<br />

[A] [A] [A]<br />

0.16 0.1...0.16 2.1 - 0.02 - - - - 100 100<br />

0.25 0.16...0.25 3.3 0.03 0.06 - - - - 100 100<br />

0.4 0.25...0.4 5.2 0.06 0.09 - - - - 100 100<br />

0.63 0.4...0.63 8.2 0.09 0.12 0.25 - - - 100 100<br />

1 0.63...1.0 13 0.12 0.25 0.55 - 1/2 1/2 100 100<br />

1.6 1.0...1.6 20.8 0.25 0.55 1.1 1/3 3/4 1 100 100<br />

2.5 1.6...2.5 32.5 0.37 0.75 1.5 1/2 1½ 1½ 100 100<br />

4 2.5...4.0 52 0.75 1.5 3 1 2 3 100 100<br />

6 4...6 78 1.5 2.2 4 1½ 5 5 100 100<br />

8 5...8 104 1.5 3 5.5 2 5 5 100 100<br />

10 6...10 130 3 4 7.5 3 7½ 10 50 38<br />

13 9...13 169 3 5.5 11 3 7½ 10 50 38<br />

17 11...17 221 4 7.5 11 5 10 15 20 15<br />

22 14...22 286 4 7.5 15 7½ 15 20 15 11<br />

26 18...26 338 5.5 11 18.5 7½ 15 20 15 11<br />

32 22...32 416 7.5 15 22 10 20 30 15 11<br />

40 28~40 520 7.5 18.5 30 15 30 40 10 8<br />

10 6~10 130 3 4 7.5 3 7½ 10 100 100<br />

13 9~13 169 3 5.5 11 3 7½ 10 50 38<br />

17 11~17 221 4 7.5 11 5 10 15 25 19<br />

22 14~22 286 4 7.5 15 7½ 15 20 25 19<br />

26 18~26 338 5.5 11 18.5 10 20 25 25 19<br />

32 22~32 416 7.5 15 22 10 25 30 25 19<br />

40 28~40 520 7.5 18.5 30 15 30 40 25 19<br />

50 34~50 650 11 22 45 15 40 50 25 19<br />

63 45~63 819 15 30 55 20 50 60 25 19<br />

65 47~65 845 15 30 55 20 50 60 25 19<br />

17 11~17 221 4 7.5 11 5 10 15 50 38<br />

22 14~22 286 4 7.5 15 7½ 15 20 50 38<br />

26 18~26 338 5.5 11 18.5 10 20 25 50 38<br />

32 22~32 416 7.5 15 22 10 25 30 50 38<br />

40 28~40 520 7.5 18.5 30 15 30 40 50 38<br />

50 34~50 650 11 22 45 15 40 50 50 38<br />

63 45~63 819 15 30 55 20 50 60 50 38<br />

75 55~75 975 22 37 63 25 60 75 50 38<br />

90 70~90 1170 30 45 75 30 75 100 50 38<br />

100 80~100 1300 30 45 90 40 75 100 50 38<br />

10


High breaking type<br />

·Adjustable thermal release<br />

·Magnetic release 13 Ie max.<br />

·Trip class 10<br />

·Protective function<br />

·Phase-failure protection<br />

- phase-failure<br />

- short circuit<br />

- overload<br />

<strong>MMS</strong>-32H <strong>MMS</strong>-63H <strong>MMS</strong>-100H<br />

Type<br />

<strong>MMS</strong>-32H<br />

<strong>MMS</strong>-63H<br />

<strong>MMS</strong>-100H<br />

Rated Thermal Magnetic Switching of 3 phase AC motors, AC-2, AC-3<br />

400/415V<br />

operational release release 3-phase [kW] (50/60Hz) 3-phase [HP] (60Hz)<br />

current Adjustment Operating<br />

Icu Ics<br />

Ie range current 230V 400V 690V 230V 460V 575V<br />

[kA] [kA]<br />

[A] [A] [A]<br />

0.16 0.1...0.16 2.1 - 0.02 - - - - 100 100<br />

0.25 0.16...0.25 3.3 0.03 0.06 - - - - 100 100<br />

0.4 0.25...0.4 5.2 0.06 0.09 - - - - 100 100<br />

0.63 0.4...0.63 8.2 0.09 0.12 0.25 - - - 100 100<br />

1 0.63...1.0 13 0.12 0.25 0.55 - 1/2 1/2 100 100<br />

1.6 1.0...1.6 20.8 0.25 0.55 1.1 1/3 3/4 1 100 100<br />

2.5 1.6...2.5 32.5 0.37 0.75 1.5 1/2 1½ 1½ 100 100<br />

4 2.5...4.0 52 0.75 1.5 3 1 2 3 100 100<br />

6 4...6 78 1.5 2.2 4 1½ 5 5 100 100<br />

8 5...8 104 1.5 3 5.5 2 5 5 100 100<br />

10 6...10 130 3 4 7.5 3 7½ 10 100 100<br />

13 9...13 169 3 5.5 11 3 7½ 10 100 100<br />

17 11...17 221 4 7.5 11 5 10 15 50 38<br />

22 14...22 286 4 7.5 15 7½ 15 20 50 38<br />

26 18...26 338 5.5 11 18.5 7½ 15 20 50 38<br />

32 22...32 416 7.5 15 22 10 20 30 50 38<br />

40 28~40 520 7.5 18.5 30 15 30 40 40 30<br />

10 6~10 130 3 4 7.5 3 7½ 10 100 100<br />

13 9~13 169 3 5.5 11 3 7½ 10 100 100<br />

17 11~17 221 4 7.5 11 5 10 15 50 50<br />

22 14~22 286 4 7.5 15 7½ 15 20 50 50<br />

26 18~26 338 5.5 11 18.5 10 20 25 50 50<br />

32 22~32 416 7.5 15 22 10 25 30 50 50<br />

40 28~40 520 7.5 18.5 30 15 30 40 50 50<br />

50 34~50 650 11 22 45 15 40 50 50 50<br />

63 45~63 819 15 30 55 20 50 60 50 50<br />

65 47~65 845 15 30 55 20 50 60 35 27<br />

17 11~17 221 4 7.5 11 5 10 15 100 100<br />

22 14~22 286 4 7.5 15 7½ 15 20 100 50<br />

26 18~26 338 5.5 11 18.5 10 20 25 100 50<br />

32 22~32 416 7.5 15 22 10 25 30 100 50<br />

40 28~40 520 7.5 18.5 30 15 30 40 100 50<br />

50 34~50 650 11 22 45 15 40 50 100 50<br />

63 45~63 819 15 30 55 20 50 60 100 50<br />

75 55~75 975 22 37 63 25 60 75 75 50<br />

90 70~90 1170 30 45 75 30 75 100 75 50<br />

100 80~100 1300 30 45 90 40 75 100 75 50<br />

11


Manual Motor Starters<br />

Product Selection Guide<br />

Instantaneous type<br />

·Without thermal releases<br />

·Magnetic release 13 Ie max.<br />

·Protective function<br />

- short circuit<br />

<strong>MMS</strong>-32HI<br />

<strong>MMS</strong>-63HI<br />

<strong>MMS</strong>-100HI<br />

Type<br />

<strong>MMS</strong>-32HI<br />

<strong>MMS</strong>-63HI<br />

<strong>MMS</strong>-100HI<br />

Rated Thermal Magnetic Switching of 3 phase AC motors, AC-2, AC-3<br />

400/415V<br />

operational release release 3-phase [kW] (50/60Hz) 3-phase [HP] (60Hz)<br />

current Adjustment Operating<br />

Icu Ics<br />

Ie range current 230V 400V 690V 230V 460V 575V<br />

[kA] [kA]<br />

[A] [A] [A]<br />

0.16 - 2.1 - 0.02 - - - - 100 100<br />

0.25 - 3.3 0.03 0.06 - - - - 100 100<br />

0.4 - 5.2 0.06 0.09 - - - - 100 100<br />

0.63 - 8.2 0.09 0.12 0.25 - - - 100 100<br />

1 - 13 0.12 0.25 0.55 - 1/2 1/2 100 100<br />

1.6 - 20.8 0.25 0.55 1.1 1/3 3/4 1 100 100<br />

2.5 - 32.5 0.37 0.75 1.5 1/2 1½ 1½ 100 100<br />

4 - 52 0.75 1.5 3 1 2 3 100 100<br />

6 - 78 1.5 2.2 4 1½ 5 5 100 100<br />

8 - 104 1.5 3 5.5 2 5 5 100 100<br />

10 - 130 3 4 7.5 3 7½ 10 100 100<br />

13 - 169 3 5.5 11 3 7½ 10 100 100<br />

17 - 221 4 7.5 11 5 10 15 50 38<br />

22 - 286 4 7.5 15 7½ 15 20 50 38<br />

26 - 338 5.5 11 18.5 7½ 15 20 50 38<br />

32 - 416 7.5 15 22 10 20 30 50 38<br />

40 28~40 520 7.5 18.5 30 15 30 40 40 30<br />

10 - 130 3 4 7.5 3 7½ 10 100 100<br />

13 - 169 3 5.5 11 3 7½ 10 100 100<br />

17 - 221 4 7.5 11 5 10 15 50 50<br />

22 - 286 4 7.5 15 7½ 15 20 50 50<br />

26 - 338 5.5 11 18.5 10 20 25 50 50<br />

32 - 416 7.5 15 22 10 25 30 50 50<br />

40 - 520 7.5 18.5 30 15 30 40 50 50<br />

50 - 650 11 22 45 15 40 50 50 50<br />

63 - 819 15 30 55 20 50 60 50 50<br />

65 47~65 845 15 30 55 20 50 60 35 27<br />

17 - 221 4 7.5 11 5 10 15 100 100<br />

22 - 286 4 7.5 15 7½ 15 20 100 50<br />

26 - 338 5.5 11 18.5 10 20 25 100 50<br />

32 - 416 7.5 15 22 10 25 30 100 50<br />

40 - 520 7.5 18.5 30 15 30 40 100 50<br />

50 - 650 11 22 45 15 40 50 100 50<br />

63 - 819 15 30 55 20 50 60 100 50<br />

75 - 975 22 37 63 25 60 75 75 50<br />

90 - 1170 30 45 75 30 75 100 75 50<br />

100 - 1300 30 45 90 40 75 100 75 50<br />

12


Accessories (Electrical Auxiliaries)<br />

Type<br />

Description<br />

Connection diagram<br />

FX...<br />

Auxiliary Switch<br />

· Front mounting<br />

· 2-pole<br />

· One front mounting module<br />

per circuit breaker<br />

1NO1NC 2NO 2NC<br />

LX...<br />

Auxiliary Switch<br />

· Side mounting on the left<br />

· 2-pole<br />

· One side mounting module<br />

per circuit breaker<br />

1NO1NC 2NO 2NC<br />

LA...<br />

Any Trip Alarm Switch<br />

· Operates in case of trip<br />

· Side mounting on the left<br />

· 2-pole<br />

· Set LA first in case of using<br />

LX together<br />

(<strong>MMS</strong>-63 can not accept<br />

LX and LA together)<br />

· For <strong>MMS</strong>-32 and <strong>MMS</strong>-63/100<br />

products are separated.<br />

1NO1NC<br />

2NC<br />

LAM...<br />

Magnetic Trip Alarm Switch<br />

· Operates in case of short circuit<br />

accidents that is over 20 times of the<br />

rated current<br />

· Side mounting on the left<br />

· 2-pole<br />

· Set LAM first in case of using<br />

LX together<br />

1NO1NC 2NO 2NC<br />

13


Manual Motor Starters<br />

Product Selection Guide<br />

Accessories (Electrical Auxiliaries)<br />

Type<br />

Description<br />

Connection diagram<br />

RS...<br />

Shunt release<br />

·Side mounting on the right<br />

·One side mounting module per<br />

circuit breaker.<br />

·Can not use with RU or RUX<br />

24V 50Hz / 28V 60Hz<br />

110V 50Hz / 120V 60Hz<br />

200V 50Hz / 200~220V 60Hz<br />

220~230V 50Hz / 240~260V 60Hz<br />

240V 50Hz / 277V 60Hz<br />

380~400V 50Hz / 440~460V 60Hz<br />

415~440V 50Hz / 460~480V 60Hz<br />

RU...<br />

Undervoltage release<br />

·Side mounting on the right<br />

· One side mounting module per<br />

circuit breaker.<br />

·Can not use with RU or RUX<br />

24V 50Hz / 28V 60Hz<br />

110V 50Hz / 120V 60Hz<br />

200V 50Hz / 200~220V 60Hz<br />

220~230V 50Hz / 240~260V 60Hz<br />

240V 50Hz / 277V 60Hz<br />

380~400V 50Hz / 440~460V 60Hz<br />

415~440V 50Hz / 460~480V 60Hz<br />

RUX...<br />

Undervoltage release with Switch<br />

·Side mounting on the right<br />

·Include 2NO Auxiliary contact<br />

·One side mounting module per<br />

circuit breaker.<br />

·Can not use with RU or RUX<br />

·Can not attach to <strong>MMS</strong>-32S<br />

24V 50Hz / 28V 60Hz<br />

110V 50Hz / 120V 60Hz<br />

200V 50Hz / 200~220V 60Hz<br />

220~230V 50Hz / 240~260V 60Hz<br />

240V 50Hz / 277V 60Hz<br />

380~400V 50Hz / 440~460V 60Hz<br />

415~440V 50Hz / 460~480V 60Hz<br />

● E-Handle (Rotary-type)<br />

<strong>MMS</strong> E-Handle is a Rotary-type Handle accessory which can be attached to the front to<br />

control and verify the ON, TRIP, OFF condition of Manual<br />

Motor Starters under the situation of closing panel.<br />

·Application Model : <strong>MMS</strong>-32H/HI,<strong>MMS</strong>-63S/H/HI, <strong>MMS</strong>-100S/H/HI<br />

·Operation temp. : -20~ +60°C<br />

·CE and UL certified<br />

·Degree of protection : IP65 or UL 50 Type 3R(Separately)<br />

·Locking device : Lockable in on/off position<br />

·Material of insulation : Plastic(PA66)<br />

Type Application <strong>MMS</strong> Remarks<br />

MEH-32<br />

MEH-63<br />

MEH-100<br />

<strong>MMS</strong>-32H, 32HI<br />

<strong>MMS</strong>-63S, 63H, 63HI<br />

<strong>MMS</strong>-100S, 100H, 100HI<br />

Length of shaft :<br />

115 or 315mm<br />

14


● Phase Bus System<br />

It is a device for a parallel connection with power terminals in the circuit lined up by <strong>MMS</strong>,<br />

and it can provides the solution "Simple wiring” and “Compact wiring space”.<br />

·Application Model : <strong>MMS</strong>-32, 63<br />

·CE and UL certified<br />

·Safety Cover built-in<br />

·RoHS compliance<br />

Type<br />

Application <strong>MMS</strong><br />

Number of Rated Safety cover<br />

Terminals current attached<br />

PB-322 2<br />

PB-323<br />

3<br />

PBPC-32<br />

<strong>MMS</strong>-32S, 32H, 32HI<br />

63A<br />

PB-324 4 (32for S, H)<br />

PB-325 5<br />

PB-632<br />

2<br />

<strong>MMS</strong>-63S, 63H, 63HI<br />

108A PBPC-63<br />

PB-633 3<br />

LTB-32<br />

PB-325<br />

Model<br />

LTB-32<br />

Pole<br />

3P<br />

Mounting location<br />

Upstream<br />

IP degree of protection IP20 according to IEC 60529<br />

Rated insulation voltage (Ui) 690V according to IEC 60947-1<br />

Rated operational current (Ie)<br />

63A<br />

Terminal torque<br />

1.7 N.m- on screw clamp terminals<br />

● Diagram<br />

L1 L2 L3<br />

1<br />

3 5 7 9 11 13 15 17<br />

2 4 6 8 10 12 14 16 18<br />

M M M<br />

15


Manual Motor Starters<br />

Product Selection Guide<br />

Accessories (Electrical Auxiliaries)<br />

● Enclosure<br />

Case cover of <strong>MMS</strong> enclosure is specifically designed with dust-proof and corrosive-proof<br />

structure.<br />

Therefore, it is the optimum product to use in dusty areas such as cement plants, cotton<br />

mills as well as in the presence of corrosive gas or liquid (excl. explosive, flammable gas)<br />

such as fertilizer, refinery, and plating plant.<br />

·Application Model: <strong>MMS</strong>-32H/HI<br />

·Operation temp. : -20~ +60℃<br />

·CE and UL certified<br />

·Degree of protection : IP65<br />

·Material of insulation :Plastic(ABS)<br />

Type Application <strong>MMS</strong> Remarks<br />

EPH-32 <strong>MMS</strong>-32H, 32HI Surface mount<br />

Dial Cover<br />

● Dial Cover<br />

Dial cover is used to protect the set value from the operation that is not intended.<br />

It is supplied as standard for all <strong>MMS</strong>.<br />

·Application Model : <strong>MMS</strong>-32, 63,100 (All types)<br />

Sealing<br />

● Insulation Barrier<br />

Insulation barrier is used to enlarge the creepage distance and clearance to meet the<br />

requirement of UL.<br />

·Application Model : <strong>MMS</strong>-100<br />

Type<br />

IB100<br />

Application <strong>MMS</strong><br />

<strong>MMS</strong>-100S, 100H, 100HI<br />

● Screw mounting holder<br />

32AF <strong>MMS</strong> is only for DIN rail mountable by itself. Screw mounting holder is used to<br />

mount <strong>MMS</strong> on a panel by screws.<br />

·Application Model : <strong>MMS</strong>-32<br />

Type Application <strong>MMS</strong> Remarks<br />

MP-32 <strong>MMS</strong>-32S, 32H, 32HI For M4 screw<br />

16


● Direct adaptor and Mounting unit<br />

Direct adaptor , DA<br />

Direct adaptor is used to connect <strong>MMS</strong> directly with a contactor<br />

Mounting unit , MU<br />

This device is attached module to connect joined <strong>MMS</strong> with a contactor<br />

·Application Model : <strong>MMS</strong>+ Susol, Metasol contactor(MC-9~95, MC-6a~100a), Mini contactor<br />

Direct adaptor Mounting Applying<br />

Combined devices<br />

Frame Name unit <strong>Contactor</strong><br />

DA-16SA<br />

<strong>MMS</strong>-32S + GMC-6M~16M<br />

DA-16<br />

DA-16SD<br />

<strong>MMS</strong>-32S + GMD-6M~16<br />

Mini-MC<br />

DA-16HA<br />

<strong>MMS</strong>-32H + GMC-6M~16M<br />

DA-16HD<br />

<strong>MMS</strong>-32H + GMD-6M~16M<br />

DA-18SA<br />

<strong>MMS</strong>-32S + MC-6a~18a<br />

DA-18<br />

DA-18SD<br />

<strong>MMS</strong>-32S + MC-6a~18a DC<br />

DA-18HA<br />

<strong>MMS</strong>-32H + MC-6a~18a<br />

DA-18HD MU-45 <strong>MMS</strong>-32H + MC-6a~18a DC<br />

Metasol MC<br />

DA-22SA<br />

<strong>MMS</strong>-32S + MC-9b~22b<br />

DA-22<br />

DA-22SD<br />

<strong>MMS</strong>-32S + MC-9b~22b DC<br />

DA-22HA<br />

<strong>MMS</strong>-32H + MC-9b~22b<br />

DA-22HD<br />

<strong>MMS</strong>-32H + MC-9b~22b DC<br />

DA-32SA <strong>MMS</strong>-32S + MC-9~32(32a, 40a)<br />

DA-32<br />

DA-63<br />

DA-95<br />

DA-32SD <strong>MMS</strong>-32S + MC-9~32(32a, 40a) DC Susol,<br />

DA-32HA <strong>MMS</strong>-32H + MC-9~32(32a, 40a) Metasol MC<br />

DA-32HD<br />

<strong>MMS</strong>-32H + MC-9~32(32a, 40a) DC<br />

DA-63A<br />

MU-55<br />

<strong>MMS</strong>-63AF + MC-35~63 (50a, 65a)<br />

Susol,<br />

DA-63D <strong>MMS</strong>-63AF + MC-35~63 (50a, 65a) DC Metasol MC<br />

DA-95A<br />

<strong>MMS</strong>-100AF + MC-65~95 (75a, 85a, 100a) (Lug Type<br />

MU-70<br />

Only)<br />

DA-95D<br />

<strong>MMS</strong>-100AF + MC-65~95 (75a, 85a, 100a) DC<br />

<strong>MMS</strong>-100<br />

<strong>MMS</strong>-63<br />

<strong>MMS</strong>-32<br />

MC-95 MC-63 MC-32<br />

Note) <strong>MMS</strong> and <strong>Contactor</strong> connected with Direct adaptor.<br />

17


Manual Motor Starters<br />

Technical Information<br />

General data<br />

● Terminals<br />

<strong>MMS</strong>32S <strong>MMS</strong>32H <strong>MMS</strong>63S, 63H <strong>MMS</strong>100S, 100H<br />

Conformity to standards<br />

Approvals<br />

Terminal parts<br />

IEC60947<br />

UL508, UL508 Type E<br />

CE, UL<br />

Wire<br />

Single-core 1 conductor [mm2] / [AWG] 1...10 / 18...8 1...10 / 18...8 0.75...35 / 18...2 2.5...70 / 12...2/0<br />

2 conductor [mm2] / [AWG] 1...6 / 18...10 1...6 / 18...10 0.75...25 / 18...4 2.5...50 / 12...1/0<br />

Stranded 1 conductor [mm2] / [AWG] 1...6 / 18...10 1...6 / 18...10 0.75...35 / 18...2 2.5...70 / 12...2/0<br />

2 conductor [mm2] / [AWG] 1...6 / 18...10 1...6 / 18...10 0.75...25 / 18...4 2.5...50 / 12...1/0<br />

Flexible 1 conductor [mm2] / [AWG] 1...6 / 18...10 1...6 / 18...10 0.75...25 / 18...4 2.5...50 / 12...1/0<br />

2 conductor [mm2] / [AWG] 0.75...4 / 18...10 0.75...4 / 18...10 0.75...16 / 18...6 2.5...35 / 10...2<br />

Tightening torque [Nm] / [Ib-in] 0.8...2.5 / 7...22 0.8...2.5 / 7...22 3...4.5 / 26...39 4...6 / 35...53<br />

● Power consumption<br />

<strong>MMS</strong>32S <strong>MMS</strong>32H <strong>MMS</strong>63S, 63H <strong>MMS</strong>100S, 100H<br />

Total power loss Pv<br />

Circuit breaker at rated load [W] In = 0.16~1.6A : 4.4 In = 0.16~1.6A : 4.4 In = 10~22A : 10.2 In = 17~32A : 15<br />

operating temperature In = 2.5~26A : 7.4 In = 2.5~26A : 7.4 In = 26~63A : 9.7 In = 40~63A : 21.8<br />

In = 32A : 4.0 In = 32A : 4.0 In = 75~100A : 17.8<br />

● Mounting<br />

35mm DIN rail for <strong>MMS</strong>32~63<br />

35mm or 75mm DIN rail for <strong>MMS</strong>100<br />

- use 15mm depth for 35mm DIN rail<br />

● Caution for thermal adjustments<br />

1.Keep the setting range as shown below.<br />

2.Moving counterclockwise out of the setting range<br />

may cause the damage of the device.<br />

Operating positions<br />

DIN rail mounting<br />

● Environment<br />

Ambient air temperature<br />

storage : - 50…+ 80 °C<br />

operation : - 20…+ 60 °C<br />

Ambient temperature compensation : - 20…+ 60 °C<br />

Maximum operating altitude : 2000m<br />

Protection degree : IP20<br />

Shock resistance : 25g<br />

Vibration resistance : 5~150Hz<br />

Dial setting method<br />

3. Calibration by ambient air temperature<br />

A : set to one<br />

Calibrated automatically<br />

point lower<br />

B : set to one<br />

point higher<br />

-20℃ -5℃ +40℃ +60℃<br />

In case of using out of the standard air temperature range(-5°C~+40°C) it needs to<br />

be calibrated by one point<br />

18


● Auxiliaries<br />

Auxiliary contacts for front Auxiliary contacts for left side Alarm switch for left side<br />

mounting mounting mounting<br />

FX... LX... LA...<br />

Rated thermal current / th<br />

at 40℃ ambient temperature [A] 5 10 10<br />

at 60℃ ambient temperature [A] 3 6 6<br />

Contact class coordination<br />

according to NEMA<br />

(UL/CSA-Standards) AC A600 A600 A600<br />

DC Q300 Q300 Q300<br />

Back-up fuses gG, gL [A] 16 16 16<br />

Rated supply current [V] - 240 24 240 24 240<br />

AC-15: [A] - 3 6 4 6 4<br />

DC-13: [V] 24 220 24 220 24 220<br />

[A] 1 0.1 2 0.25 2 0.25<br />

Weight (g) 18 30 40<br />

Terminal parts<br />

Wire Pozidriv size 2<br />

Single-core 1 conductor [mm2] / [AWG] 0.5...2.5 / 20...14 0.5...2.5 / 20...14<br />

2 conductor [mm2] / [AWG] - 0.5...2.5 / 20...14<br />

Stranded 1 conductor [mm2] / [AWG] 0.5...4 / 20...10 0.5...4 / 20...10<br />

2 conductor [mm2] / [AWG] 0.75...2.5 / 18...14 0.75...2.5 / 18...14<br />

Tightening torque [Nm] / [Ib-in] 0.8...1.2 / 7...10 0.8...1.2 / 7...10<br />

Undervoltage release Undervoltage release with 2 auxiliary Shunt release<br />

for right side mounting contacts for right side mounting for right side mounting<br />

RU... RUX... RS...<br />

Actuating voltage<br />

Pull-in 0.7...1.1×Us 0.85...1.1×Us 0.85...1.1×Us<br />

Drop-out 0.7...0.35×Us 0.7...0.35×Us<br />

Rated control voltage<br />

min.: 24V 50Hz / 28V 60Hz 24V 50Hz / 28V 60Hz 24V 50Hz / 28V 60Hz<br />

max.: 415~440V 50Hz / 460~480V 60Hz 415~440V 50Hz / 460~480V 60Hz 415~440V 50Hz / 460~480V 60Hz<br />

Coil rating<br />

Pull-in 8.5VA, 6W 8.5VA, 6W 8.5VA, 6W<br />

Hold 3VA, 1.2W 3VA, 1.2W 3VA, 1.2W<br />

Opening time (ms) - 20 20<br />

Weight (g) 18 30 40<br />

Terminal parts<br />

Wire Pozidriv size 2<br />

Single-core 1 conductor [mm2] / [AWG] 0.5...2.5 / 20...14<br />

2 conductor [mm2] / [AWG] 0.5...2.5 / 20...14<br />

Stranded 1 conductor [mm2] / [AWG] 0.5...4 / 20...10<br />

2 conductor [mm2] / [AWG] 0.75...2.5 / 18...14<br />

Tightening torque [Nm] / [Ib-in] 0.8...1.2 / 7...10<br />

19


Manual Motor Starters<br />

Technical Information<br />

General data<br />

● Installation of auxiliaries<br />

Be sure to turn off the main switch of <strong>MMS</strong><br />

before any other action.<br />

<strong>MMS</strong>-32S/H/HI<br />

•To install FX remove the cover 1 first.<br />

•2 each of LX can be installed together.<br />

•Only one of auxiliaries among RU, RS and RUX can<br />

be mounted on the right side of <strong>MMS</strong>.<br />

•Do not give trip signal to RS longer than 10 sec.<br />

•Refer to the possible combination chart for the<br />

mounting of LX, LA and LAM on left side of <strong>MMS</strong>.<br />

•Push the trip button before installation of LAM<br />

•Remove the indicated part in the fig.<br />

before the additional installation of LX<br />

Separation of auxiliaries from <strong>MMS</strong><br />

•be sure to turn off the main switch of <strong>MMS</strong><br />

before the separation.<br />

•push softly the separation button on the side<br />

of the auxiliary and pull it.<br />

※Please make sure to choose proper LA before use because LA for <strong>MMS</strong>-32<br />

and <strong>MMS</strong>-63/100 is different.<br />

20


<strong>MMS</strong>-63, 100S/H/HI<br />

•To install FX remove the cover 1 first.<br />

•2 each of LX can be installed together.<br />

(only 1 each for <strong>MMS</strong>-63)<br />

•Only one of auxiliaries among RU, RS and RUX can<br />

be mounted on the right side of <strong>MMS</strong>.<br />

•Do not give trip signal to RS longer than 10 sec.<br />

•Refer to the possible combination chart for the<br />

mounting of LX, LA and LAM on left side of <strong>MMS</strong>.<br />

•Do not use with LA-... (32)<br />

It is only for <strong>MMS</strong>-32.<br />

•Push the trip button before installation of LAM<br />

•Do not install LA in the status of TRIP of <strong>MMS</strong>-100<br />

•Remove the indicated part as shown in the above fig.<br />

before the additional installation of LX<br />

Separation of auxiliaries from <strong>MMS</strong><br />

•be sure to turn off the main switch of <strong>MMS</strong><br />

before the separation.<br />

•push softly the separation button on the side of the<br />

auxiliary and pull it.<br />

※Please make sure to choose proper LA before use because LA for <strong>MMS</strong>-32<br />

and <strong>MMS</strong>-63/100 is different.<br />

21


Manual Motor Starters<br />

Technical Information<br />

General data<br />

● Installation of auxiliaries<br />

How to Install and reset RUX<br />

Installing<br />

(1) Check if the trip button of RUX is "UP" .<br />

If not, push the side lever 1 to come it up.<br />

(2) Fit the both lower hooks 2 into the <strong>MMS</strong>.<br />

(3) Rotate the handle of <strong>MMS</strong> to the<br />

20 to 30 degree 3 to ON direction and keep it.<br />

(4) Fit the both upper hooks 4into the <strong>MMS</strong>.<br />

(5) Input power to the RUX.<br />

(6) Turn ON the handle of <strong>MMS</strong>.<br />

Resetting<br />

The trip button of RUX does not come "UP"<br />

in the event of tripping due to undervoltage.<br />

To turn ON the <strong>MMS</strong> after the tripping<br />

1 turn OFF the <strong>MMS</strong> and check if the trip button<br />

of RUX comes "UP" .<br />

2 push the trip button<br />

3 turn ON the <strong>MMS</strong><br />

Insulation<br />

Insulation barrier<br />

Reset<br />

Dial cover<br />

* Only for <strong>MMS</strong>-100 * For all <strong>MMS</strong><br />

Combination with mini contactors<br />

Adaptor <strong>MMS</strong> + <strong>Contactor</strong> model<br />

DA-16SA <strong>MMS</strong>-32S + GMC-6M~16M<br />

DA-16SD <strong>MMS</strong>-32S + GMD-6M~16M<br />

DA-16HA <strong>MMS</strong>-32H, 32HI + GMC-6M~16M<br />

DA-16HD <strong>MMS</strong>-32H, 32HI + GMD-6M~16M<br />

DA-18SA <strong>MMS</strong>-32S + MC-6a~18a<br />

DA-18SD <strong>MMS</strong>-32S + MC-6a~18a DC<br />

DA-18HA <strong>MMS</strong>-32H + MC-6a~18a<br />

DA-18HD <strong>MMS</strong>-32H + MC-6a~18a DC<br />

DA-22SA <strong>MMS</strong>-32S + MC-9b~22b<br />

DA-22SD <strong>MMS</strong>-32S + MC-9b~22b DC<br />

DA-22HA <strong>MMS</strong>-32H, 32HI + MC-9b~22b<br />

DA-22HD <strong>MMS</strong>-32H, 32HI + MC-9b~22b DC<br />

DA-32SA <strong>MMS</strong>-32S + MC-9~32(32a, 40a)<br />

DA-32SD <strong>MMS</strong>-32S + MC-9~32(32a, 40a) DC<br />

DA-32HA <strong>MMS</strong>-32H, 32HI + MC-9~32(32a, 40a)<br />

DA-32HD <strong>MMS</strong>-32H, 32HI + MC-9~32(32a, 40a) DC<br />

DA-63A <strong>MMS</strong>-63S, 63H, 63HI + MC-35~63(50a, 65a)<br />

DA-63D <strong>MMS</strong>-63S, 63H, 63HI + MC-35~63(50a, 65a) DC<br />

DA-95A <strong>MMS</strong>-100S, 100H, 100HI + MC-65~95(75a, 85a, 100a) /<br />

Lug Type Only<br />

DA-95D <strong>MMS</strong>-100S, 100H, 100HI + MC-65~95(75a, 85a, 100a)<br />

DC / Lug Type Only<br />

Note)<br />

Note)<br />

* RUX : can not attach to <strong>MMS</strong>-32S<br />

Possible combination chart<br />

Please read this chart completely before installing the<br />

auxiliaries.<br />

Improper combination can cause electric<br />

failure or accident.<br />

Note) LA(32 on 63/100 is a sparate).<br />

22


● E-Handle<br />

Structure<br />

Locking Device<br />

When opening the panel door at ON position<br />

Locking<br />

Installation at OF, OFF position<br />

Setting to regular position through turning the handle<br />

Open Panel Door<br />

On Position<br />

(Vertical State)<br />

Off Position<br />

(Horizontal State)<br />

Pushing<br />

Locking<br />

Releasing<br />

23


Manual Motor Starters<br />

Technical Information<br />

General data<br />

● E-Handle<br />

Installation<br />

Projection should be passed through<br />

the hole when assembling<br />

Projection should be passed through<br />

the hole when assembling<br />

Restricted fact of Assembling<br />

Assembling is available for <strong>MMS</strong>-63/100 with 4 holes on the main cover<br />

which is produced after June, 2007 based on manufacturing date.<br />

24


Operating Test<br />

※Caution<br />

If trying to open the<br />

door at ON or Trip<br />

position, locking knob<br />

can be damaged.<br />

At On position<br />

Panel door<br />

can not be<br />

opened<br />

At Trip position<br />

Panel door can<br />

not be opened.<br />

At Off position<br />

Panel door can<br />

be opened<br />

Cutting off the shaft & applying the handle<br />

25


Manual Motor Starters<br />

Technical Information<br />

General data<br />

● Enclosure<br />

26


IEC performance data (Motor protection)<br />

Standard type<br />

● <strong>MMS</strong> 32S<br />

Rated operational current Ie [A] 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6 8 10 13 17 22 26 32 40<br />

Switching of standard<br />

three-phase motors<br />

AC-2, AC-3<br />

230/240V [kW] - 0.03 0.06 0.09 0.12 0.18/0.25 0.37 0.55/0.75 1.1/1.5 1.5 2.2/3 3 3.7/4 4 5.5 7.5 7.5<br />

400/415V [kW] 0.02 0.06 0.09 0.12 0.18/0.25 0.37/0.55 0.75 1.1/1.5 2.2 3 3.7/4 5.5 7.5 7.5 11 15 18.5<br />

500V [kW] - - - 0.25 0.37 0.55/0.75 1.1 1.5/2.2 3 3.7 4/5.5 7.5 11 11 15 18.5 22<br />

690V [kW] - - - 0.25 0.37/0.55 0.75/1.1 1.5 2.2/3 3.7/4 5.5 7.5 11 11 15 18.5 22 30<br />

Back-up fuses<br />

gG, gL,, only if Icc>Icu<br />

( * = No back up fuse required)<br />

230/240V [A] * * * * * * * * * * * * * 125 125 125 160<br />

400/415V [A] * * * * * * * * * * 80 80 100 100 100 100 125<br />

440/460V [A] * * * * * * * 50 50 63 63 80 80 100 100 100 100<br />

500V [A] * * * * * * 50 40 50 63 63 80 80 80 80 80 80<br />

690V [A] * * * * * 20 35 40 50 63 63 63 63 63 63 63 63<br />

Ultimate short-circuit<br />

breaking capacity Icu<br />

230/240V [kA] 100 100 100 100 100 100 100 100 100 100 100 100 50 40 40 30 20<br />

400/415V [kA] 100 100 100 100 100 100 100 100 100 100 50 50 20 15 15 15 10<br />

440/460V [kA] 100 100 100 100 100 100 100 50 15 15 15 10 10 8 8 6 5<br />

500V [kA] 100 100 100 100 100 100 50 15 10 10 6 6 6 6 6 5 4<br />

690V [kA] 100 100 100 100 100 3 3 3 3 3 3 3 3 3 3 3 2<br />

Rated service short-circuit<br />

breaking capacity Ics<br />

230/240V [kA] 100 100 100 100 100 100 100 100 100 100 100 100 38 30 30 22 15<br />

400/415V [kA] 100 100 100 100 100 100 100 100 100 100 38 38 15 11 11 11 8<br />

440/460V [kA] 100 100 100 100 100 100 100 38 11 11 11 8 8 6 6 4 3<br />

500V [kA] 100 100 100 100 100 100 38 11 8 8 5 5 5 5 5 4 3<br />

690V [kA] 100 100 100 100 100 3 3 3 3 3 3 3 3 3 3 3 2<br />

● <strong>MMS</strong> 63S<br />

Rated operational current Ie [A] 10 13 17 22 26 32 40 50 63 65<br />

Switching of standard<br />

three-phase motors<br />

AC-2, AC-3<br />

230/240V [kW] 2.2/3 3 3.7/4 4 5.5 7.5 7.5 11 15 15<br />

400/415V [kW] 3.7/4 5.5 7.5 7.5 11 15 18.5 22 30 30<br />

500V [kW] 4/5.5 7.5 11 11 15 18.5 22 30 37 37<br />

690V [kW] 7.5 11 11 15 18.5 22 30 45 55 55<br />

Back-up fuses<br />

gG, gL,, only if Icc>Icu<br />

( * = No back up fuse required)<br />

230/240V [A] * * * 125 125 160 160 160 200 200<br />

400/415V [A] * 80 100 125 125 125 125 160 160 180<br />

440/460V [A] 80 80 100 100 100 100 100 100 125 125<br />

500V [A] 80 80 80 80 80 80 80 80 80 80<br />

690V [A] 63 63 63 63 63 63 63 63 80 60<br />

Ultimate short-circuit<br />

breaking capacity Icu<br />

230/240V [kA] 100 100 100 50 50 50 50 50 50 50<br />

400/415V [kA] 100 50 25 25 25 25 25 25 25 25<br />

440/460V [kA] 15 10 10 10 10 10 10 10 10 10<br />

500V [kA] 10 6 6 6 6 6 6 6 6 6<br />

690V [kA] 4 4 4 4 4 4 4 4 4 4<br />

Rated service short-circuit<br />

breaking capacity Ics<br />

230/240V [kA] 100 100 100 38 38 38 38 38 38 38<br />

400/415V [kA] 100 38 19 19 19 19 19 19 19 19<br />

440/460V [kA] 12 8 8 8 8 8 8 8 8 8<br />

500V [kA] 8 5 5 5 5 5 5 5 5 5<br />

690V [kA] 3 3 3 3 3 3 3 3 3 3<br />

27


Manual Motor Starters<br />

Technical Information<br />

IEC performance data (Motor protection)<br />

Standard type<br />

● <strong>MMS</strong> 100S<br />

Rated operational current Ie [A] 17 22 26 32 40 50 63 75 90 100<br />

Switching of standard<br />

three-phase motors<br />

AC-2, AC-3<br />

230/240V [kW] 3.7/4 4 5.5 7.5 7.5 11 15 22 30 30<br />

400/415V [kW] 7.5 7.5 11 15 18.5 22 30 37 45 45<br />

500V [kW] 11 11 15 18.5 22 30 37 45 55 63<br />

690V [kW] 11 15 18.5 22 30 45 55 63 75 90<br />

Back-up fuses<br />

gG, gL,, only if Icc>Icu<br />

( * = No back up fuse required)<br />

230/240V [A] * * * * * * * * * *<br />

400/415V [A] 100 125 125 125 160 160 160 160 160 160<br />

440/460V [A] 100 125 125 125 125 125 160 160 160 160<br />

500V [A] 100 100 100 100 100 100 100 125 125 125<br />

690V [A] 63 80 80 80 80 80 80 100 125 125<br />

Ultimate short-circuit<br />

breaking capacity Icu<br />

230/240V [kA] 100 100 100 100 100 100 100 100 100 100<br />

400/415V [kA] 50 50 50 50 50 50 50 50 50 50<br />

440/460V [kA] 40 40 40 40 40 40 40 40 40 40<br />

500V [kA] 25 25 25 15 15 12 12 8 8 8<br />

690V [kA] 10 10 10 10 6 6 6 5 5 5<br />

Rated service short-circuit<br />

breaking capacity Ics<br />

230/240V [kA] 100 100 100 100 100 100 100 100 100 100<br />

400/415V [kA] 38 38 38 38 38 38 38 38 38 38<br />

440/460V [kA] 30 30 30 30 30 30 30 30 30 30<br />

500V [kA] 19 19 19 11 11 9 9 6 6 6<br />

690V [kA] 8 8 8 8 5 5 5 4 4 4<br />

High breaking type<br />

● <strong>MMS</strong> 32H<br />

Rated operational current Ie [A] 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6 8 10 13 17 22 26 32 40<br />

Switching of standard<br />

three-phase motors<br />

AC-2, AC-3<br />

230/240V [kW] - 0.03 0.06 0.09 0.12 0.18/0.25 0.37 0.55/0.75 1.1/1.5 1.5 2.2/3 3 3.7/4 4 5.5 7.5 7.5<br />

400/415V [kW] 0.02 0.06 0.09 0.12 0.18/0.25 0.37/0.55 0.75 1.1/1.5 2.2 3 3.7/4 5.5 7.5 7.5 11 15 1.8<br />

500V [kW] - - - 0.25 0.37 0.55/0.75 1.1 1.5/2.2 3 3.7 4/5.5 7.5 11 11 15 18.5 22<br />

690V [kW] - - - 0.25 0.37/0.55 0.75/1.1 1.5 2.2/3 3.7/4 5.5 7.5 11 11 15 18.5 22 30<br />

Back-up fuses<br />

gG, gL,, only if Icc>Icu<br />

( * = No back up fuse required)<br />

230/240V [A] * * * * * * * * * * * * * * * * *<br />

400/415V [A] * * * * * * * * * * * * 100 125 125 125 160<br />

440/460V [A] * * * * * * * * * 80 80 80 80 100 100 100 125<br />

500V [A] * * * * * * * * * 63 80 80 80 80 80 80 100<br />

690V [A] * * * * * * 35 40 50 63 63 63 63 63 63 63 80<br />

Ultimate short-circuit<br />

breaking capacity Icu<br />

230/240V [kA] 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100<br />

400/415V [kA] 100 100 100 100 100 100 100 100 100 100 100 100 50 50 50 50 40<br />

440/460V [kA] 100 100 100 100 100 100 100 100 100 50 50 50 20 20 20 20 15<br />

500V [kA] 100 100 100 100 100 100 100 100 100 50 50 42 10 10 10 10 8<br />

690V [kA] 100 100 100 100 100 100 8 8 6 6 6 6 4 4 4 4 3<br />

Rated service short-circuit<br />

breaking capacity Ics<br />

230/240V [kA] 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100<br />

400/415V [kA] 100 100 100 100 100 100 100 100 100 100 100 100 38 38 38 38 30<br />

440/460V [kA] 100 100 100 100 100 100 100 100 100 38 38 38 15 15 15 15 11<br />

500V [kA] 100 100 100 100 100 100 100 100 100 38 38 32 8 8 8 8 6<br />

690V [kA] 100 100 100 100 100 100 8 8 6 6 6 6 4 4 4 4 3<br />

Note) * = Short circuit proof up to 50 or 100kA. No back up fuse required.<br />

28


High breaking type<br />

● <strong>MMS</strong> 63H<br />

Rated operational current Ie [A] 10 13 17 22 26 32 40 50 63 65<br />

Switching of standard<br />

three-phase motors<br />

AC-2, AC-3<br />

230/240V [kW] 2.2/3 3 3.7/4 4 5.5 7.5 7.5 11 15 15<br />

400/415V [kW] 3.7/4 5.5 7.5 7.5 11 15 18.5 22 30 30<br />

500V [kW] 4/5.5 7.5 11 11 15 18.5 22 30 37 37<br />

690V [kW] 7.5 11 11 15 18.5 22 30 45 55 55<br />

Back-up fuses<br />

gG, gL,, only if Icc>Icu<br />

( * = No back up fuse required)<br />

230/240V [A] * * * * * * * * * *<br />

400/415V [A] * * 100 125 125 125 160 160 160 160<br />

440/460V [A] 100 100 100 125 125 125 125 125 160 160<br />

500V [A] 100 100 100 100 100 100 100 100 100 100<br />

690V [A] 63 63 63 80 80 80 80 80 80 80<br />

Ultimate short-circuit<br />

breaking capacity Icu<br />

230/240V [kA] 100 100 100 100 100 100 100 100 100 75<br />

400/415V [kA] 100 100 50 50 50 50 50 50 50 35<br />

440/460V [kA] 50 50 50 50 35 35 35 35 35 25<br />

500V [kA] 50 42 12 12 12 10 10 10 10 6<br />

690V [kA] 6 6 5 5 5 5 5 5 5 3<br />

Rated service short-circuit<br />

breaking capacity Ics<br />

230/240V [kA] 100 100 100 100 100 100 100 100 100 50<br />

400/415V [kA] 100 100 50 50 50 50 50 50 50 27<br />

440/460V [kA] 38 38 38 38 27 27 27 27 27 19<br />

500V [kA] 38 32 9 9 9 8 8 8 8 5<br />

690V [kA] 5 5 5 5 5 5 5 5 5 3<br />

Note) * = Short circuit proof up to 50 or 100kA. No back up fuse required.<br />

● <strong>MMS</strong> 100H<br />

Rated operational current Ie [A] 17 22 26 32 40 50 63 75 90 100<br />

Switching of standard<br />

three-phase motors<br />

AC-2, AC-3<br />

230/240V [kW] 3.7/4 4 5.5 7.5 7.5 11 15 22 30 30<br />

400/415V [kW] 7.5 7.5 11 15 18.5 22 30 37 45 45<br />

500V [kW] 11 11 15 18.5 22 30 37 45 55 63<br />

690V [kW] 11 15 18.5 22 30 45 55 63 75 90<br />

Back-up fuses<br />

gG, gL,, only if Icc>Icu<br />

( *= No back up fuse required)<br />

230/240V [A] * * * * * * * * * *<br />

400/415V [A] * * * * * * * * * *<br />

440/460V [A] 125 125 125 160 160 160 200 200 200 200<br />

500V [A] 100 125 125 125 160 160 160 160 160 160<br />

690V [A] 80 80 80 80 80 100 100 125 160 160<br />

Ultimate short-circuit<br />

breaking capacity Icu<br />

230/240V [kA] 100 100 100 100 100 100 100 100 100 100<br />

400/415V [kA] 100 100 100 100 100 100 100 75 75 75<br />

440/460V [kA] 50 50 50 50 50 50 50 50 50 50<br />

500V [kA] 35 35 35 25 20 15 15 12 12 12<br />

690V [kA] 12 12 12 12 12 10 8 6 6 6<br />

Rated service short-circuit<br />

breaking capacity Ics<br />

230/240V [kA] 100 100 100 100 100 100 100 100 100 100<br />

400/415V [kA] 100 50 50 50 50 50 50 50 50 50<br />

440/460V [kA] 38 38 38 38 38 38 38 38 38 38<br />

500V [kA] 27 27 27 19 15 11 11 9 9 9<br />

690V [kA] 9 9 9 9 9 8 6 6 6 6<br />

Note) * = Short circuit proof up to 50 or 100kA. No back up fuse required.<br />

29


Manual Motor Starters<br />

Technical Information<br />

IEC performance data (Motor protection)<br />

High breaking type<br />

● <strong>MMS</strong> 32HI<br />

Rated operational current Ie [A] 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6 8 10 13 17 22 26 32 40<br />

AC-2, AC-3<br />

230/240V [kW] - 0.03 0.06 0.09 0.12 0.18/0.25 0.37 0.55/0.75 1.1/1.5 1.5 2.2/3 3 3.7/4 4 5.5 7.5 7.5<br />

400/415V [kW] 0.02 0.06 0.09 0.12 0.18/0.25 0.37/0.55 0.75 1.1/1.5 2.2 3 3.7/4 5.5 7.5 7.5 11 15 18.5<br />

500V [kW] - - - 0.25 0.37 0.55/0.75 1.1 1.5/2.2 3 3.7 4/5.5 7.5 11 11 15 18.5 22<br />

690V [kW] - - - 0.25 0.37/0.55 0.75/1.1 1.5 2.2/3 3.7/4 5.5 7.5 11 11 15 18.5 22 30<br />

Back-up fuses<br />

gG, gL,, only if Icc>Icu<br />

( * = No back up fuse required)<br />

230/240V [A] * * * * * * * * * * * * * * * * *<br />

400/415V [A] * * * * * * * * * * * * 100 125 125 125 160<br />

440/460V [A] * * * * * * * * * 80 80 80 80 100 100 100 125<br />

500V [A] * * * * * * * * * 63 80 80 80 80 80 80 100<br />

690V [A] * * * * * * 35 40 50 63 63 63 63 63 63 63 80<br />

Ultimate short-circuit<br />

breaking capacity Icu<br />

230/240V [kA] 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100<br />

400/415V [kA] 100 100 100 100 100 100 100 100 100 100 100 100 50 50 50 50 40<br />

440/460V [kA] 100 100 100 100 100 100 100 100 100 50 50 50 20 20 20 20 15<br />

500V [kA] 100 100 100 100 100 100 100 100 100 50 50 42 10 10 10 10 8<br />

690V [kA] 100 100 100 100 100 100 8 8 6 6 6 6 4 4 4 4 3<br />

Rated service short-circuit<br />

breaking capacity Ics<br />

230/240V [kA] 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100<br />

400/415V [kA] 100 100 100 100 100 100 100 100 100 100 100 100 38 38 38 38 30<br />

440/460V [kA] 100 100 100 100 100 100 100 100 100 38 38 38 15 15 15 15 11<br />

500V [kA] 100 100 100 100 100 100 100 100 100 38 38 32 8 8 8 8 6<br />

690V [kA] 100 100 100 100 100 100 8 8 6 6 6 6 4 4 4 4 3<br />

● <strong>MMS</strong> 63HI<br />

Rated operational current Ie [A] 10 13 17 22 26 32 40 50 63 65<br />

AC-2, AC-3<br />

230/240V [kW] 2.2/3 3 3.7/4 4 5.5 7.5 7.5 11 15 15<br />

400/415V [kW] 3.7/4 5.5 7.5 7.5 11 15 18.5 22 30 30<br />

500V [kW] 4/5.5 7.5 11 11 15 18.5 22 30 37 37<br />

690V [kW] 7.5 11 11 15 18.5 22 30 45 55 55<br />

Back-up fuses<br />

gG, gL,, only if Icc>Icu<br />

( * = No back up fuse required)<br />

230/240V [A] * * * * * * * * * *<br />

400/415V [A] * * 100 125 125 125 160 160 160 160<br />

440/460V [A] 100 100 100 125 125 125 125 125 160 160<br />

500V [A] 100 100 100 100 100 100 100 100 100 100<br />

690V [A] 63 63 63 80 80 80 80 80 80 80<br />

Ultimate short-circuit<br />

breaking capacity Icu<br />

230/240V [kA] 100 100 100 100 100 100 100 100 100 75<br />

400/415V [kA] 100 100 50 50 50 50 50 50 50 35<br />

440/460V [kA] 50 50 50 50 35 35 35 35 35 25<br />

500V [kA] 50 42 12 12 12 10 10 10 10 6<br />

690V [kA] 6 6 5 5 5 5 5 5 5 3<br />

Rated service short-circuit<br />

breaking capacity Ics<br />

230/240V [kA] 100 100 100 100 100 100 100 100 100 50<br />

400/415V [kA] 100 100 50 50 50 50 50 50 50 27<br />

440/460V [kA] 38 38 38 38 27 27 27 27 27 19<br />

500V [kA] 38 32 9 9 9 8 8 8 8 5<br />

690V [kA] 5 5 5 5 5 5 5 5 5 3<br />

● <strong>MMS</strong> 100HI<br />

Rated operational current Ie [A] 17 22 26 32 40 50 63 75 90 100<br />

AC-2, AC-3<br />

230/240V [kW] 3.7/4 4 5.5 7.5 7.5 11 15 22 30 30<br />

400/415V [kW] 7.5 7.5 11 15 18.5 22 30 37 45 45<br />

500V [kW] 11 11 15 18.5 22 30 37 45 55 63<br />

690V [kW] 11 15 18.5 22 30 45 55 63 75 90<br />

Back-up fuses<br />

gG, gL,, only if Icc>Icu<br />

( * = No back up fuse required)<br />

230/240V [A] * * * * * * * * * *<br />

400/415V [A] * * * * * * * * * *<br />

440/460V [A] 125 125 125 160 160 160 200 200 200 200<br />

500V [A] 100 125 125 125 160 160 160 160 160 160<br />

690V [A] 80 80 80 80 80 100 100 125 160 160<br />

Ultimate short-circuit<br />

breaking capacity Icu<br />

230/240V [kA] 100 100 100 100 100 100 100 100 100 100<br />

400/415V [kA] 100 100 100 100 100 100 100 75 75 75<br />

440/460V [kA] 50 50 50 50 50 50 50 50 50 50<br />

500V [kA] 35 35 35 25 20 15 15 12 12 12<br />

690V [kA] 12 12 12 12 12 10 8 6 6 6<br />

Rated service short-circuit<br />

breaking capacity Ics<br />

230/240V [kA] 100 100 100 100 100 100 100 100 100 100<br />

400/415V [kA] 100 50 50 50 50 50 50 50 50 50<br />

440/460V [kA] 38 38 38 38 38 38 38 38 38 38<br />

500V [kA] 27 27 27 19 15 11 11 9 9 9<br />

690V [kA] 9 9 9 9 9 8 6 6 6 6<br />

30


Manual motor controller (UL 508, CSA C22.2 as Manual motor controllers)<br />

Combination Motor Controller<br />

- Group lnstallation<br />

- Type E starter<br />

● <strong>MMS</strong> 32S<br />

Rated operational current Ie [A] 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6 8 10 13 17 22 26 32 40<br />

Max. short-circuit current<br />

240V [kA] 100 100 100 100 100 100 100 100 100 100 50 50 40 30 30 20 20<br />

480V [kA] 50 50 50 50 50 50 50 50 25 25 10 10 10 10 7.5 7.5 7.5<br />

600V [kA] 10 10 10 10 10 10 10 5 5 5 5 5 5 5 5 5 5<br />

Motor load<br />

1 Phase 115V [HP] - - - - - - - 1/8 1/4 1/3 1/2 1/2 1 1½ 2 2 3<br />

230V [HP] - - - - - 1/10 1/6 1/3 1/2 1 1½ 2 3 3 3 5 7½<br />

3 Phase 200V [HP] - - - - - - 1/2 3/4 1 2 2 3 3 5 7½ 7½ 10<br />

230V [HP] - - - - - - 1/2 3/4 1½ 2 3 3 5 7½ 7½ 10 10<br />

460V [HP] - - - - - 3/4 1 2 3 5 5 7½ 10 15 15 20 30<br />

575V [HP] - - - - 1/2 3/4 1½ 3 5 5 7½ 10 15 20 20 30 30<br />

Max. fuse size [A] 1 1 1 1 3 6 10 15 20 30 40 50 60 80 100 125 125<br />

Max. breaker size [A] 15 15 15 15 15 15 15 15 20 30 40 50 60 80 100 125 125<br />

● <strong>MMS</strong> 63S<br />

Rated operational current Ie [A] 10 13 17 22 26 32 40 50 63 65<br />

Max. short-circuit current<br />

240V [kA] 100 100 100 100 100 100 100 100 100 100<br />

480V [kA] 50 50 40 40 40 40 40 40 40 40<br />

600V [kA] 10 10 10 10 10 10 10 10 10 10<br />

Motor load<br />

1 Phase 115V [HP] 1/2 1/2 1 1½ 2 2 3 3 5 5<br />

230V [HP] 1½ 2 3 3 3 5 7½ 10 10 10<br />

3 Phase 200V [HP] 2 3 3 5 7½ 7½ 10 15 20 20<br />

230V [HP] 3 3 5 7½ 7½ 10 10 15 20 20<br />

460V [HP] 5 7½ 10 15 15 20 30 30 40 40<br />

575V [HP] 7½ 10 15 20 20 30 30 40 60 60<br />

Maximum rated current<br />

of fuse or breaker<br />

[A] 600 600 600 600 600 600 600 600 600 600<br />

● <strong>MMS</strong> 100S<br />

Rated operational current Ie [A] 17 22 26 32 40 50 63 75 90 100<br />

Max. short-circuit current<br />

240V [kA] 100 100 100 100 100 100 100 100 100 100<br />

480V [kA] 50 50 50 50 50 50 40 40 40 40<br />

600V [kA] 10 10 10 10 10 10 10 10 10 10<br />

Motor load<br />

1 Phase 115V [HP] 1 1½ 2 2 3 3 5 5 7½ 10<br />

230V [HP] 3 3 3 5 7½ 10 10 15 20 20<br />

3 Phase 200V [HP] 3 5 7½ 7½ 10 15 20 20 25 30<br />

230V [HP] 5 7½ 7½ 10 10 15 20 25 30 30<br />

460V [HP] 10 15 15 20 30 30 40 50 60 75<br />

575V [HP] 15 20 20 30 30 40 60 60 75 100<br />

Maximum rated current<br />

of fuse or breaker<br />

[A] 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000<br />

In case of 1-phase use<br />

in series as shown below<br />

31


Manual Motor Starters<br />

Technical Information<br />

Manual motor controller (UL 508, CSA C22.2 as Manual motor controllers)<br />

Combination Motor Controller<br />

- Group lnstallation<br />

- Type E starter<br />

● <strong>MMS</strong> 32H<br />

Rated operational current Ie [A] 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6 8 10 13 17 22 26 32 40<br />

Max. short-circuit current<br />

240V [kA] 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100<br />

480V [kA] 65 65 65 65 65 65 65 65 65 65 65 65 30 30 30 30 30<br />

600V [kA] 25 25 25 25 25 25 25 25 25 25 25 25 10 10 10 10 10<br />

Motor load<br />

1 Phase 115V [HP] - - - - - - - 1/8 1/4 1/3 1/2 1/2 1 1½ 2 2 3<br />

230V [HP] - - - - - 1/10 1/6 1/3 1/2 1 1½ 2 3 3 3 5 7½<br />

3 Phase 200V [HP] - - - - - - 1/2 3/4 1 2 2 3 3 5 7½ 7½ 10<br />

230V [HP] - - - - - - 1/2 3/4 1½ 2 3 3 5 7½ 7½ 10 10<br />

460V [HP] - - - - - 3/4 1 2 3 5 5 7½ 10 15 15 20 30<br />

575V [HP] - - - - 1/2 3/4 1½ 3 5 5 7½ 10 15 20 20 30 30<br />

Maximum rated current<br />

of fuse or breaker<br />

[A] 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500<br />

● <strong>MMS</strong> 63H<br />

Rated operational current Ie [A] 10 13 17 22 26 32 40 50 63 65<br />

Max. short-circuit current<br />

240V [kA] 100 100 100 100 100 100 100 100 100 100<br />

480V [kA] 65 65 50 50 50 50 50 50 50 50<br />

600V [kA] 25 25 10 10 10 10 10 10 10 10<br />

Motor load<br />

1 Phase 115V [HP] 1/2 1/2 1 1½ 2 2 3 3 5 5<br />

230V [HP] 1½ 2 3 3 3 5 7½ 10 10 10<br />

3 Phase 200V [HP] 2 3 3 5 7½ 7½ 10 15 20 20<br />

230V [HP] 3 3 5 7½ 7½ 10 10 15 20 20<br />

460V [HP] 5 7½ 10 15 15 20 30 30 40 40<br />

575V [HP] 7½ 10 15 20 20 30 30 40 60 60<br />

Maximum rated current<br />

of fuse or breaker<br />

[A] 600 600 600 600 600 600 600 600 600 600<br />

● <strong>MMS</strong> 100H<br />

Rated operational current Ie [A] 17 22 26 32 40 50 63 75 90 100<br />

Max. short-circuit current<br />

240V [kA] 100 100 100 100 100 100 100 100 100 100<br />

480V [kA] 65 65 65 65 65 65 50 50 50 50<br />

600V [kA] 25 25 25 20 20 20 10 10 10 10<br />

Motor load<br />

1 Phase 115V [HP] 1 1½ 2 2 3 3 5 5 7½ 10<br />

230V [HP] 3 3 3 5 7½ 10 10 15 20 20<br />

3 Phase 200V [HP] 3 5 7½ 7½ 10 15 20 20 25 30<br />

230V [HP] 5 7½ 7½ 10 10 15 20 25 30 30<br />

460V [HP] 10 15 15 20 30 30 40 50 60 75<br />

575V [HP] 15 20 20 30 30 40 60 60 75 100<br />

Maximum rated current<br />

of fuse or breaker<br />

[A] 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000<br />

In case of 1-phase use<br />

in series as shown below<br />

32


Manual Motor Controller (UL508)<br />

● <strong>MMS</strong> 32S<br />

Rated operational current Ie [A] 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6 8 10 13 17 22 26 32 40<br />

Max. short-circuit current<br />

240V [kA] 100 100 100 100 100 100 100 100 100 100 50 50 40 30 30 20 20<br />

480V [kA] 50 50 50 50 50 50 50 50 25 25 10 10 10 10 7.5 7.5 7.5<br />

600V [kA] 10 10 10 10 10 10 10 5 5 5 5 5 5 5 5 5 5<br />

Motor load<br />

1 Phase 115V [HP] - - - - - - - 1/8 1/4 1/3 1/2 1/2 1 1½ 2 2 3<br />

230V [HP] - - - - - 1/10 1/6 1/3 1/2 1 1½ 2 3 3 3 5 7½<br />

3 Phase 200V [HP] - - - - - - 1/2 3/4 1 2 2 3 3 5 7½ 7½ 10<br />

230V [HP] - - - - - - 1/2 3/4 1½ 2 3 3 5 7½ 7½ 10 10<br />

460V [HP] - - - - - 3/4 1 2 3 5 5 7½ 10 15 15 20 30<br />

575V [HP] - - - - 1/2 3/4 1½ 3 5 5 7½ 10 15 20 20 30 30<br />

Max. fuse size [A] 1 1 1 1 3 6 10 15 20 30 40 50 60 80 100 125 150<br />

Max. breaker size [A] 15 15 15 15 15 15 15 15 20 30 40 50 60 80 100 125 150<br />

● <strong>MMS</strong> 63S<br />

Rated operational current Ie [A] 10 13 17 22 26 32 40 50 63 65<br />

Max. short-circuit current<br />

240V [kA] 100 100 100 100 100 100 100 100 100 100<br />

480V [kA] 25 25 25 25 25 25 25 25 25 25<br />

600V [kA] 10 10 10 10 10 10 10 10 10 10<br />

Motor load<br />

1 Phase 115V [HP] 1/2 1/2 1 1½ 2 2 3 3 5 5<br />

230V [HP] 1½ 2 3 3 3 5 7½ 10 10 10<br />

3 Phase 200V [HP] 2 3 3 5 7½ 7½ 10 15 20 20<br />

230V [HP] 3 3 5 7½ 7½ 10 10 15 20 20<br />

460V [HP] 5 7½ 10 15 15 20 30 30 40 40<br />

575V [HP] 7½ 10 15 20 20 30 30 40 60 60<br />

Max. fuse size [A] 40 50 60 80 100 125 150 200 250 250<br />

Max. breaker size [A] 40 50 60 80 100 125 150 200 250 250<br />

● <strong>MMS</strong> 100S<br />

Rated operational current Ie [Ie] 17 22 26 32 40 50 63 75 90 100<br />

Max. short-circuit current<br />

240V [kA] 100 100 100 100 100 100 100 100 100 100<br />

480V [kA] 25 25 25 25 25 25 25 25 25 25<br />

600V [kA] 10 10 10 10 10 10 10 10 10 10<br />

Motor load<br />

1 Phase 115V [HP] 1 1½ 2 2 3 3 5 5 7½ 10<br />

230V [HP] 3 3 3 5 7½ 10 10 15 20 20<br />

3 Phase 200V [HP] 3 5 7½ 7½ 10 15 20 20 25 30<br />

3 Phase 230V [HP] 5 7½ 7½ 10 10 15 20 25 30 30<br />

460V [HP] 10 15 15 20 30 30 40 50 60 75<br />

575V [HP] 15 20 20 30 30 40 60 60 75 100<br />

Max. fuse size [A] 60 80 100 125 150 200 250 300 350 400<br />

Max. breaker size [A] 60 80 100 125 150 200 250 300 350 400<br />

In case of 1-phase use<br />

in series as shown below<br />

33


Manual Motor Starters<br />

Technical Information<br />

Manual Motor Controller (UL508)<br />

● <strong>MMS</strong> 32H<br />

Rated operational current Ie [A] 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6 8 10 13 17 22 26 32 40<br />

Max. short-circuit current<br />

240V [kA] 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100<br />

480V [kA] 50 50 50 50 50 50 50 50 50 50 50 50 30 30 30 30 30<br />

600V [kA] 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10<br />

Motor load<br />

1 Phase 115V [HP] - - - - - - - 1/8 1/4 1/3 1/2 1/2 1 1½ 2 2 3<br />

230V [HP] - - - - - 1/10 1/6 1/3 1/2 1 1½ 2 3 3 3 5 7½<br />

3 Phase 200V [HP] - - - - - - 1/2 3/4 1 2 2 3 3 5 7½ 7½ 10<br />

230V [HP] - - - - - - 1/2 3/4 1½ 2 3 3 5 7½ 7½ 10 10<br />

460V [HP] - - - - - 3/4 1 2 3 5 5 7½ 10 15 15 20 30<br />

575V [HP] - - - - 1/2 3/4 1½ 3 5 5 7½ 10 15 20 20 30 30<br />

Max. fuse size [A] 1 1 1 1 3 6 10 15 20 30 40 50 60 80 100 125 150<br />

Max. breaker size [A] 15 15 15 15 15 15 15 15 20 30 40 50 60 80 100 125 150<br />

● <strong>MMS</strong> 63H<br />

Rated operational current Ie [A] 10 13 17 22 26 32 40 50 63 65<br />

Max. short-circuit current<br />

240V [kA] 100 100 100 100 100 100 100 100 100 100<br />

480V [kA] 50 50 50 50 50 50 50 50 50 50<br />

600V [kA] 10 10 10 10 10 10 10 10 10 10<br />

Motor load<br />

1 Phase 115V [HP] 1/2 1/2 1 1½ 2 2 3 3 5 5<br />

230V [HP] 1½ 2 3 3 3 5 7½ 10 10 10<br />

3 Phase 200V [HP] 2 3 3 5 7½ 7½ 10 15 20 20<br />

230V [HP] 3 3 5 7½ 7½ 10 10 15 20 20<br />

460V [HP] 5 7½ 10 15 15 20 30 30 40 40<br />

575V [HP] 7½ 10 15 20 20 30 30 40 60 60<br />

Max. fuse size [A] 40 50 60 80 100 125 150 200 250 250<br />

Max. breaker size [A] 40 50 60 80 100 125 150 200 250 250<br />

● <strong>MMS</strong> 100H<br />

Rated operational current Ie [Ie] 17 22 26 32 40 50 63 75 90 100<br />

Max. short-circuit current<br />

240V [kA] 100 100 100 100 100 100 100 100 100 100<br />

480V [kA] 50 50 50 50 50 50 50 50 50 50<br />

600V [kA] 10 10 10 10 10 10 10 10 10 10<br />

Motor load<br />

1 Phase 115V [HP] 1 1½ 2 2 3 3 5 5 7½ 10<br />

230V [HP] 3 3 3 5 7½ 10 10 15 20 20<br />

3 Phase 200V [HP] 3 5 7½ 7½ 10 15 20 20 25 30<br />

230V [HP] 5 7½ 7½ 10 10 15 20 25 30 30<br />

460V [HP] 10 15 15 20 30 30 40 50 60 75<br />

575V [HP] 15 20 20 30 30 40 60 60 75 100<br />

Max. fuse size [A] 60 80 100 125 150 200 250 300 350 400<br />

Max. breaker size [A] 60 80 100 125 150 200 250 300 350 400<br />

In case of 1-phase use<br />

in series as shown below<br />

34


Type '2' coordination according to IEC 947-4-1<br />

● Short-circuit current Iq = 50kA<br />

Voltage : 400/415V, 50/60Hz<br />

Standard motors<br />

Manual motor starter<br />

AC-3 Thermal overload Magnetic release<br />

at 400/415V Circuit breaker release response current<br />

1500rpm<br />

setting range<br />

<strong>Contactor</strong><br />

[kW] [A] Type [A] [A] Type [A]<br />

- - <strong>MMS</strong>-32S 0.16A 0.1~0.16 2.08 GMC-6M / GMC-9 6 / 9<br />

0.06 0.2 <strong>MMS</strong>-32S 0.25A 0.16~0.25 3.25 GMC-6M / GMC-9 6 / 9<br />

0.09 0.3 <strong>MMS</strong>-32S 0.4A 0.25~0.4 5.2 GMC-6M / GMC-9 6 / 9<br />

0.12 0.4 <strong>MMS</strong>-32S 0.63A 0.4~0.63 8.19 GMC-6M / GMC-9 6 / 9<br />

0.18 0.6 <strong>MMS</strong>-32S 0.63A 0.4~0.63 8.19 GMC-6M / GMC-9 6 / 9<br />

0.25 0.8 <strong>MMS</strong>-32S 1A 0.63~1 13 GMC-6M / GMC-9 6 / 9<br />

0.37 1.1 <strong>MMS</strong>-32S 1.6A 1~1.6 20.8 GMC-6M / GMC-9 6 / 9<br />

0.55 1.5 <strong>MMS</strong>-32S 1.6A 1~1.6 20.8 GMC-6M / GMC-9 6 / 9<br />

0.75 1.9 <strong>MMS</strong>-32S 2.5A 1.6~2.5 32.5 GMC-12 12<br />

1.1 2.7 <strong>MMS</strong>-32S 4A 2.5~4 52 GMC-18 18<br />

1.5 3.6 <strong>MMS</strong>-32S 4A 2.5~4 52 GMC-18 18<br />

2.2 5.2 <strong>MMS</strong>-32S 6A 4~6 78 GMC-18 18<br />

3 6.8 <strong>MMS</strong>-32S 8A 5~8 104 GMC-18 18<br />

4 9 <strong>MMS</strong>-32S 10A 6~10 130 GMC-18 18<br />

5.5 11.5 <strong>MMS</strong>-32H 13A 9~13 169 GMC-22 22<br />

7.5 15.5 <strong>MMS</strong>-32H 17A 11~17 221 GMC-22 22<br />

10 20 <strong>MMS</strong>-32H 22A 14~22 286 GMC-32 32<br />

11 22 <strong>MMS</strong>-32H 26A 18~26 338 GMC-32 32<br />

15 29 <strong>MMS</strong>-32H 32A 22~32 416 GMC-32 32<br />

18.5 35 <strong>MMS</strong>-63H 40A 28~40 520 GMC-50 50<br />

22 41 <strong>MMS</strong>-63H 50A 34~50 650 GMC-50 50<br />

30 55 <strong>MMS</strong>-63H 63A 45~63 819 GMC-65 65<br />

37 67 <strong>MMS</strong>-100S 75A 55~75 975 GMC-75 75<br />

45 80 <strong>MMS</strong>-100S 100A 80~100 1300 GMC-85 85<br />

Definition type '2' coordination according to IEC 947-4-1 :<br />

•The contactor or the starter must not endanger persons or systems in the event of a short-circuit.<br />

•The contactor or the starter must be suitable for further use.<br />

•No damage to the overload relay or other parts may occur with the exception of welding of the<br />

contactor or starter contacts provided that these can be easily separated without significant<br />

deformation (such as with a screwdriver).<br />

35


Manual Motor Starters<br />

Technical Information<br />

Time/Current characteristic<br />

Ⅰ) Thermal release trip current :<br />

The adjustable inverse bimetal trip reliability protects motors against overloads.<br />

The curve shows the mean operating current at an ambient temperature of 20℃ starting from cold.<br />

Careful testing and setting ensures effective motor protection even in the case of single-phasing.<br />

Ⅱ) Magnetic release trip current :<br />

The instantaneous magnetic trip has a fixed operating current setting.<br />

This corresponds to 13times the maximum value of setting range,<br />

at a lower setting it is correspondingly higher.<br />

Current setting Ie :<br />

The overload trip corresponds to a thermal overload relay in a motor starter conforming to IEC 947-4-1.<br />

If a different value is prescribed (e.g. reduced Ie for cooling medium having a temperature higher<br />

than 40℃ or a place of installation higher than 2000m above sea level),<br />

the setting current is equal to the reduced rated current Ie of the motor.<br />

36


Thermal limit on short circuit for <strong>MMS</strong><br />

Thermal limit in kA 2 s in the magnetic operating zone (Ue=415V)<br />

● <strong>MMS</strong>-32S/H/HI<br />

Sum of I 2 dt (I 2 t)<br />

100<br />

10<br />

32A<br />

26A<br />

22A<br />

17A<br />

13A<br />

10A<br />

8A<br />

6A<br />

4A<br />

2.5A<br />

1<br />

1.6A<br />

0.1<br />

1A<br />

0.01<br />

0.1 1 10 100<br />

Icc rms(A)<br />

Peak current Ip (kA)<br />

100<br />

10<br />

32A<br />

26A<br />

22A<br />

17A<br />

13A<br />

10A<br />

8A<br />

6A<br />

4A<br />

1<br />

2.5A<br />

1.6A<br />

1A<br />

0.1<br />

0.01<br />

0.1 1 10 100<br />

Icc rms(A)<br />

37


Manual Motor Starters<br />

Technical Information<br />

Thermal limit on short circuit for <strong>MMS</strong><br />

Thermal limit in kA 2 s in the magnetic operating zone (Ue=415V)<br />

● <strong>MMS</strong>-63S/H/HI<br />

Sum of I 2 dt (I 2 t)<br />

1000<br />

100<br />

63A<br />

50A<br />

40A<br />

32A<br />

26A<br />

22A<br />

17A<br />

13A<br />

10A<br />

10<br />

1<br />

0.1<br />

0.1 1 10 100<br />

Icc rms(A)<br />

Peak current Ip (kA)<br />

100<br />

10<br />

63A<br />

50A<br />

40A<br />

32A<br />

26A<br />

22A<br />

17A<br />

13A<br />

10A<br />

1<br />

0.1 1 10 100<br />

Icc rms(A)<br />

38


Thermal limit in kA 2 s in the magnetic operating zone (Ue=415V)<br />

● <strong>MMS</strong>-100S/H/HI<br />

Peak current Ip (kA)<br />

10000<br />

1000<br />

100A<br />

90A<br />

75A<br />

63A<br />

50A<br />

40A<br />

32A<br />

Peak current Ip (kA)<br />

100<br />

26A<br />

22A<br />

17A<br />

100<br />

10<br />

10<br />

1<br />

0.1 1 10 100<br />

Icc rms(A)<br />

1<br />

0<br />

100A<br />

90A<br />

75A<br />

63A<br />

50A<br />

40A<br />

32A<br />

26A<br />

22A<br />

17A<br />

Peak current Ip (kA)<br />

100<br />

100A<br />

90A<br />

75A<br />

63A<br />

50A<br />

40A<br />

32A<br />

26A<br />

22A<br />

17A<br />

10<br />

10 100<br />

Icc rms(A)<br />

1<br />

0.1 1 10 100<br />

Icc rms(A)<br />

39


Manual Motor Starters<br />

Technical Information<br />

Dimension<br />

● <strong>MMS</strong> 32S<br />

[mm]<br />

0.32kg<br />

(+45mm)<br />

1) Side auxiliary switch<br />

2) Side magnetic trip alarm<br />

switch<br />

3) Side shunt release or<br />

Side undervoltage release<br />

4) Front auxiliary switch<br />

5) Push-in Lugs for screw<br />

mounting<br />

6) 35mm standard mounting<br />

rail acc. to EN 50 022<br />

<strong>MMS</strong>-32S+PB-32(2, 3 Terminal)<br />

PB-322(2 Terminal), PB-323(3 Terminal)<br />

PB-324(4 Terminal), PB-325(5 Terminal)<br />

40


● <strong>MMS</strong> 32H, 32HI<br />

[mm]<br />

0.36kg<br />

(+45mm)<br />

1) Side auxiliary switch<br />

2) Side magnetic trip alarm<br />

switch<br />

3) Side shunt release or<br />

Side undervoltage release<br />

4) Front auxiliary switch<br />

5) Handle lock in OFF<br />

position(Ø5mm)<br />

6) Push-in Lugs for screw<br />

mounting<br />

7) 35mm standard mounting<br />

rail acc. to EN 50 022<br />

<strong>MMS</strong>-32H/HI+PB-32(2, 3 Terminal)<br />

PB-322(2 Terminal), PB-323(3 Terminal)<br />

PB-324(4 Terminal), PB-325(5 Terminal)<br />

41


Manual Motor Starters<br />

Technical Information<br />

Dimension<br />

● <strong>MMS</strong> 63S, 63H, 63HI<br />

[mm]<br />

1kg<br />

1) Side auxiliary switch<br />

2) Side magnetic trip alarm<br />

switch<br />

3) Side shunt release or<br />

Side undervoltage release<br />

4) Front auxiliary switch<br />

5) Handle lock in OFF<br />

position(Ø5mm)<br />

6) 35mm standard mounting<br />

rail acc. to EN 50 022<br />

<strong>MMS</strong>-63S/H/HI+PB-63(2, 3 Terminal)<br />

PB-632(2 Terminal), PB-633(3 Terminal)<br />

42


● <strong>MMS</strong> 100S, 100H, 100HI<br />

[mm]<br />

2.2kg<br />

1) Side auxiliary switch<br />

2) Side magnetic trip alarm<br />

switch<br />

3) Side shunt release or<br />

Side undervoltage release<br />

4) Front auxiliary switch<br />

5) Handle lock in OFF<br />

position(Ø5mm)<br />

6) 35mm standard mounting<br />

rail acc. to EN 50 022<br />

7) 75mm standard mounting<br />

rail acc. to EN 50 023<br />

8) 4mm hexagon socket screw<br />

43


Manual Motor Starters<br />

Technical Information<br />

Dimension<br />

● <strong>MMS</strong> + Mini-MS<br />

[mm]<br />

44


● <strong>MMS</strong> + Susol MC<br />

[mm]<br />

45


Manual Motor Starters<br />

Technical Information<br />

Dimension<br />

● <strong>MMS</strong> + Susol MC<br />

[mm]<br />

46


● E-Handle<br />

[mm]<br />

E-Handle Type A(mm) <strong>MMS</strong> Type<br />

MEH-32, 115<br />

MEH-32, 315<br />

MEH-63, 115<br />

MEH-63, 315<br />

MEH-100, 115<br />

MEH-100, 315<br />

min : 148.6<br />

max:210.6(Shaft 115mm)<br />

min : 148.6<br />

max:410.6(Shaft 315mm)<br />

min : 193.6<br />

max:255.6(Shaft 115mm)<br />

min : 193.6<br />

max:455.6(Shaft 315mm)<br />

min : 220<br />

max:282(Shaft 115mm)<br />

min : 220<br />

max:482(Shaft 315mm)<br />

<strong>MMS</strong>-32H/32HI<br />

<strong>MMS</strong>-63S/63H/63HI<br />

<strong>MMS</strong>-100S/100H/100HI<br />

47


Manual Motor Starters<br />

Technical Information<br />

Dimension<br />

● Enclosure<br />

[mm]<br />

14<br />

● Phase Bus<br />

PB-322/323<br />

85 (2 <strong>MMS</strong>)<br />

130 (3 <strong>MMS</strong>)<br />

175 (4 <strong>MMS</strong>)<br />

220 (5 <strong>MMS</strong>)<br />

PB-632/633<br />

48


Memo<br />

49


Manual Motor Starters<br />

Memo<br />

50


Safety Instructions<br />

•For your safety, please read user's manual thoroughly before operating.<br />

•Contact the nearest authorized service facility for examination, repair, or adjustment.<br />

•Please contact qualified service technician when you need maintenance.<br />

Do not disassemble or repair by yourself!<br />

•Any maintenance and inspection shall be performed by the personnel having expertise concerned.<br />

c 2003.12 <strong>LSIS</strong> Co.,Ltd. All rights reserved.<br />

www.lsis.com<br />

■ HEAD OFFICE<br />

LS-ro 127 (Hogye-dong) Dongan-gu, Anyang-si,<br />

Gyeonggi-Do Korea<br />

Tel. 82-2-2034-4902, 4684, 4429<br />

Fax. 82-2-2034-4555<br />

■ GLOBAL NETWORK<br />

Overseas Subsidiaries<br />

•<strong>LSIS</strong> USA Inc. ≫ Chicago, America<br />

2000 Millbrook Drive, Lincolnshire, Chicago, IL 60069, United States of America<br />

Tel: 1-847-941-8240 Fax: 1-847-941-8259 E-mail: seungheonc@lsis.com<br />

•<strong>LSIS</strong> (Middle East) FZE ≫ Dubai, U.A.E.<br />

LOB 19-205, JAFZA View Tower, Jebel Ali Free Zone, Dubai, United Arab Emirates<br />

Tel: 971-4-886-5360 Fax: 971-4-886-5361 E-mail: hschoib@lsis.com<br />

•<strong>LSIS</strong> Europe B.V. ≫ Schiphol-Rijk, Netherlands<br />

1st Floor, Tupoleviaan 48, 1119NZ, Schiphol-Rijk, The Netherlands<br />

Tel: 31-20-654-1420 Fax: 31-20-654-1429 E-mail: junshickp@lsis.com<br />

•<strong>LSIS</strong> Japan Co., Ltd. ≫ Tokyo, Japan<br />

Tokyo Club Building 13F, 2-6, Kasumigaseki 3-chome, Chiyoda-ku, Tokyo, 100-0013<br />

Tel: 81-3-6268-8241 Fax: 81-3-6268-8240 E-mail: jschuna@lsis.com<br />

•<strong>LSIS</strong>(Dalian) Co., Ltd. ≫ Dalian, China<br />

No. 15, Liaohexi 3-Road, Economic and Technical Development Zone, Dalian 116600, China<br />

Tel: 86-411-8273-7777 Fax: 86-411-8730-7560 E-mail: tangyh@lsis.com<br />

• LS IS(Wuxi) Co., Ltd. ≫ WUxi, China<br />

102-A , National High & New Tech Industrial Development Area, Wuxi, Jiangsu, 214028, P.R.China<br />

Tel: 86-510-8534-6666 Fax: 86-510-522-4078 E-mail: wangzy@lsis.com<br />

•LS-Vina Co., Ltd. ≫ Hanoi, Vietnam<br />

Nguyen Khe, Dong Anh, Hanoi, Vietnam<br />

Tel: 84-4-6275-8055 Fax: 84-4-3882-0220 E-mail: sjbaik@lsis.com<br />

Specifications in this catalog are subject to change without notice due to<br />

continuous product development and improvement.<br />

2015. 09<br />

Overseas Branches<br />

•<strong>LSIS</strong> Co., Ltd. Rep. Office, Vietnam<br />

Gema Dept Tower 18F, 6 Le Thanh Ton, District 1, HCM, Vietnam<br />

Tel: 84-8-3823-7890 E-mail: hwyim@lsis.com<br />

•<strong>LSIS</strong> Moscow Office, Russia<br />

123610, Krasnopresnenskaya, nab, 12, building1, office No.1005, Moscow, Russia<br />

Tel: 7-495-258-1466, 1467 Fax: 7-495-258-1466, 1467 E-mail: jdpark1@lsis.com<br />

Manual Motor Starters (E) 2003. 12/(27) 2015. 09 Printed in Korea STAFF

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!