20.09.2012 Views

MicroCT Systems and Software

MicroCT Systems and Software

MicroCT Systems and Software

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>MicroCT</strong> <strong>Systems</strong> <strong>and</strong> <strong>Software</strong>


human cortical bone 3 �m voxelsize<br />

foam (PPO) 1.75 �m voxelsize<br />

dragonfly head 10 �m voxelsize<br />

Scanco - Scanners, <strong>Software</strong> <strong>and</strong> Contract<br />

Research Services:<br />

Applications:<br />

- Bone quality measurements<br />

- Nondestructive testing<br />

- Implant measurements<br />

- Dental research<br />

- Scaffolds<br />

- Development of advanced composite materials<br />

- Vascular research<br />

High resolution scanners for accurate results:<br />

- Non-Destructive analysis<br />

- No sample preparation required<br />

- High throughput (batch mode processing, automatic sample loader)<br />

- Custom system configuration available<br />

- Very fast acquisition, reconstruction <strong>and</strong> analyses<br />

- Automatic sample changer (�CT 35, 40, 50, 80 <strong>and</strong> �CT 100)<br />

- Physiological monitoring <strong>and</strong> gating for vivaCT 40 <strong>and</strong> vivaCT 75<br />

- �CT 35 for objects up to 75 mm diameter (special conditions apply)<br />

- �CT 40 for objects up to 37 mm diameter<br />

- �CT 50 for objects up to 50 mm diameter<br />

- �CT 80 for objects up to 76 mm diameter<br />

- �CT 100 for objects up to 100 mm diameter<br />

- vivaCT 40 for in vivo applications (small animals) up to 39 mm diameter<br />

- vivaCT 75 for in vivo applications (small animals) up to 80 mm diameter<br />

- XtremeCT for in vivo applications (clinical <strong>and</strong> preclinical) up to 126mm<br />

diameter<br />

<strong>Software</strong>:<br />

- Morphometry <strong>and</strong> density measurements<br />

- Contact area calculations, pore analysis<br />

- Visualisation in 2D <strong>and</strong> 3D<br />

- Finite Element Analysis<br />

Over 300 systems installed <strong>and</strong> in operation worldwide in leading<br />

academic <strong>and</strong> industrial laboratories<br />

Scanco Medical also provides contract scan service as well as quality<br />

assurance/image analysis services for multi-site studies (conducted on<br />

Scanco Medical <strong>Systems</strong> only)


�CT 50 (wood pores)<br />

MicroTomography <strong>Systems</strong><br />

�CT 80 (FEA of human femur) �CT 40 (mouse brain, blood vessel cast)<br />

�CT 50 (cortical bone, thickness map)<br />

vivaCT 75 (rat) �CT 40 (dental implant)


Specifications<br />

Specimen <strong>Systems</strong> μCT 40 μCT 35 μCT 80<br />

Peak Energy 30-90 kVp 30-90 kVp 30-90 kVp<br />

Max. Scan Diameter 36.9 mm 37.9 mm 75.8 mm<br />

Max. Scan Length/Height 80 mm 120 mm 140 mm<br />

Automatic Sample Changer Option up to 10 holders up to 8 holders -<br />

Resolution (Nom. /10% MTF) 3-72 μm /