Conventional PFC losses in OBC<br />

PFC stage power loss breakdown<br />

› Total losses: 96,5W<br />

32,5%<br />

Output<br />

Source: Design of High Efficiency High Power Density 10,5kW<br />

3ph PBC for (H)Evs, G. Yang <strong>and</strong> all, PCIM Europe 2016<br />

› In a st<strong>and</strong>ard boost PFC the input stage is still today using diodes since:<br />

› No need for control signal;<br />

› HV mosfets so far didn’t have a low enough Rds-on vs price to become competitive<br />

versus diodes. Now the use of new generation technologies or new material allows<br />

this.<br />

Power dissipated in the input bridge is high compared to the global balance;<br />

2017-05-11 Copyright © Infineon Technologies AG 2017. All rights reserved.<br />