iDIALOG 400VA - 1600VA - Off-Line UPS<br />

3 YEAR WARRANTY ON ALL UPS AND BATTERIES<br />

DESCRIPTION W*D*H REF €/EA £/EA<br />

400VA/240W iDialog (with 6 mins Full / 9 mins Typical Load) 90*232*192 IDG 400 157.66 141.89<br />

600VA/360W iDialog (with 6 mins Full / 7 mins Typical Load) 90*232*192 IDG 600 157.66 141.89<br />

800VA/480W iDialog (with 4 mins Full / 5 mins Typical Load) 90*232*192 IDG 800 166.40 149.75<br />

1.2kVA/720W iDialog (with 3 mins Full / 6 mins Typical Load) 97*315*275 IDG <strong>120</strong>0 270.60 243.54<br />

1.6kVA/960W iDialog (with 3 mins Full / 7 mins Typical Load) 97*315*275 IDG 1600 369.77 332.78<br />

VISION DUAL (Tower or Rack*) 1.1kVA – 3.0kVA – Line Interactive UPS<br />

DESCRIPTION W*D*H REF €/EA £/EA<br />

1.1kVA/990W Vision Dual (with 5 mins Full Load) 87(2U)*425*450 (19”) VSD 1100 634.79 571.31<br />

1.5kVA/1.35kW Vision Dual (with 4 mins Full Load) 87(2U)*425*450 (19”) VSD 1500 811.80 730.62<br />

2.2kVA/1.98kW Vision Dual (with 5 mins Full Load) 87(2U)*625*450 (19”) VSD 2000 931.13 838.02<br />

3.0kVA/2.7kW Vision Dual (with 5 mins Full Load) 87(2U)*625*450 (19”) VSD 3000 1567.92 1411.12<br />

*Rack Mounting Rails (600 – 1000mm deep) 81.26 73.12<br />

Note: VSD 2200 & VSD 3000 require 16A Supply<br />

Sentinel Pro 700VA-3000VA Single Phase – Tower<br />

DESCRIPTION W*D*H REF €/EA £/EA<br />

700VA/560W Sentinel Pro (with 6 mins Full Load) 158*422*235 SEP 700 780.02 702.02<br />

1.0kVA/800W Sentinel Pro (with 7 mins Full Load) 158*422*235 SEP 1000 864.30 777.88<br />

1.5kVA/1.2kW Sentinel Pro (with 5 mins Full Load) 158*422*235 SEP 1500 1111.03 999.92<br />

2.2kVA/1.76kW Sentinel Pro (with 6 mins Full Load) 190*446*333 SEP 2200 1319.69 1187.72<br />

3.0kVA/2.4kW Sentinel Pro (with 5 mins Full Load) 190*446*333 SEP 3000 1667.84 1501.05<br />

Note: SEP 3000 requires 16A Supply<br />

Off-Line, Line Interactive & On-Line Double Conversion… what’s the difference?<br />

Off-Line UPS will only kick in once the power has failed, or dropped below c. 172V... so basically, if the input voltage is 180V, then the<br />

output is 180V. The voltage needs to drop below c. 172V for the UPS to kick in, and give an output of 230V (+/- 10%) on battery.<br />

Line Interactive UPS use automatic voltage regulation (AVR) to correct abnormal voltages without switching to battery. The UPS<br />

detects when voltage crosses a preset low (c. 162V) or high (c. 192V) threshold value and uses transformers to boost or lower the voltage<br />

by a set amount to return it to the acceptable range. So basically, if the input voltage is 180V, then the output is 230V. These UPS’s will<br />

clean the input voltage, and always give an output of 230V.<br />

On-Line Double Conversion UPS use a more precise method of voltage regulation: they continuously convert incoming AC power to<br />

DC power (rectifier) and then convert the DC power to ideal AC output power (inverter). This continuous double conversion operation<br />

isolates connected equipment from problems on the AC line, including blackouts, brownouts, overvoltages, surges, line noise, harmonic<br />

distortion, electrical impulses and frequency variations. So basically, these UPS’s will clean and protect the input voltage, and always give<br />

a perfect output of 230V.