Designed to ensure you are prepared to treat all GI bleeding or closure

situations, wherever you are in the GI tract.


The OTSC® System is intended for:

• Endoscopic treatment of

gastrointestinal hemorrhage

• Closure of acute wall lesions

• Closure of chronic wall lesions


Tried, Tested & Trusted

• The OTSC® System has been featured on the cover of

multiple peer-reviewed journals

• To date, there have been over 400 clinical publications

on the OTSC® System confirming clinical effectiveness

in a multitude of clinical situations (peptic ulcers,

dieulafoy lesions, Mallory Weiss tears, fistula and

perforation closures, etc…)

• Clinical evidence indicates that OTSC® is superior to

standard treatment for high risk NVUGIB and authors

recommend OTSC® as first-line treatment for HR-AO

bleeding.



Case example: 11/6t for acute, spurting (F1a) duodenal ulcer bleeding



Functional principles of the OTSC®: dynamic compression

• The OTSC® clip is a superelastic nitinol clip which

compresses the tissue in between its teeth and enables

dynamic closure rather than static closure.

• Unlike fixed sutures, the OTSC® clip maintains

consistent compression while adapting continuously to

the thickness of the tissue; even when the volume of the

tissue is shrinking over the healing course.

• The space between the teeth allow micro-perfusion of

the clipped tissue. Therefore no necrosis of the tissue

occurs.


OTSC® Specifications

because one size doesn’t fit all……


OTSC® Specifications

because one size doesn’t fit all……


OTSC® Specifications

because one size doesn’t fit all……


OTSC® Specifications- Labeling

because one size doesn’t fit all……


mini OTSC

• Smaller version of the OTSC System

• Applications – access difficulties and smaller anatomical considerations

• Designed with the ring deployment mechanism of the FTRD System

• Reduced OD maximum width of 17.13 mm (OTSC size 11) to 14.65 mm

• Compatible with endoscopes: 8.5 – 9.8 / 10 mm

• Smaller size OTSC clip: 10a und 10t – 3mm depth cap only

OTSC 11t

mini OTSC 10t

mini OTSC System (left)

OTSC System 11 (right)


OTSC® Application: Suction Technique

In most GI bleeding situations, tissue can be mobilized and

securely pulled inside the application cap by simply applying

endoscopic suction. Once the target tissue is captured inside

the cap, hemostasis is achieved by simply turning the

handwheel to release the OTSC® clip around the captured

tissue.


OTSC® Application: Suction Technique

Case example: hemostasis of diverticula bleeding in the sigmoid colon (using suction)

Source: Dr. Thomas Kratt, Interventional Endoscopy, Klinik für Allgemeine, Viszeral- und Transplantationschirurgie, University Hospital Tübingen, Germany


OTSC® Application: Anchor Technique

In cases of fibrotic or hard tissue (e.g. ulcers) or

tangential application, the OTSC® Anchor can be

valuable in precisely pulling the targeted tissue

inside the cap and keeping it fixed during clip

release.


OTSC® Application: Anchor Technique

Grasping of fistula opening

(here pre-treated with

APC) with OTSC® Anchor

Cap is positioned on the

lesion (Anchor is used as a

guide)

Retracting the shaft of the

OTSC® Anchor into cap; clip

application

Closure of fistula opening with

the OTSC® clip

Case example: closure of persistent PEG-fistula using the OTSC® Anchor

Source: Dr. Thomas Kratt, Interventional Endoscopy, Klinik für Allgemeine, Viszeral- und Transplantationschirurgie, University Hospital Tübingen, Germany


OTSC® Application: Twin Grasper® Technique

The OTSC® Twin Grasper® facilitates the

approximation of opposing edges of a lesion (e.g.

perforations) before release of the OTSC® clip. The

Twin Grasper® has two jaws that can be opened

independently of each other.


OTSC® Application: Twin Grasper® Technique

Locate the perforation

Grasp each edge of the perforation, each with one jaw of the

OTSC® Twin Grasper®

Closure of perforation with the

OTSC® clip

Case example: closure of a colonic perforation using the OTSC® Twin Grasper®

Source: Dr. Thomas Kratt, Interventional Endoscopy, Klinik für Allgemeine, Viszeral- und Transplantationschirurgie, University Hospital Tübingen, Germany


OTSC® v. The Competition (Padlock)

There is a reason why OTSC is the market leader!!

• Proven clinical results

• 100,000+ clinical cases

• 400+ Clinical Publications

• Ovesco–OTSC product family portfolio

(Padlock - 2 cap sizes do not fit all clinical needs)

• 4 cap and clip sizes (mini, 11,12,14)

• 2 cap depth designs (3mm, 6mm)

• 3 clip configurations (A, T, GC)

• Proprietary tissue grasping devices

• Ovesco is the FTRD® company

• Ovesco has the remOVE System

• Ovesco has more to come………


Ovesco Endoscopy USA Contact information

Ovesco Endoscopy USA

120 Quade Dr.

Cary, NC 27513

Phone: 919 651 9449

customerservice@ovesco-usa.com

www.ovesco.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!