12.08.2020 Views

Noise Barriers Product Reference Guide

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

QuietLine

TM

TRANSPORTATION

Barrier Wall Systems:

Absorptive noise control barriers provide maximum noise

reduction with lightweight modular panels and/or louvers.

The noise barrier system is easy to install and easy

to relocate. Panels and louvers are constructed of

galvanized steel or aluminum and finish painted

in a weather and salt resistant polyester powder

coating. The finish is also graffiti resistant and

cleanable.

Acoustic Performance Data

1/3 Octave Band Center Frequency, Hz 125 250 500 1K 2K 4K STC

Sound Transmission Loss Data, dB

V-Stack Aluminum 14 20 31 42 40 52 33

V-Stack Steel 22 26 35 45 47 48 38

SL Barrier 18 26 35 45 49 52 37

H/P 38 24 25 33 43 50 55 38

Free-Standing or Elevated Panel Construction

• Allows for maximum flexibility of design and utility on the

ground or on the rooftop

• One– or two-sided sound absorption

• Steel or aluminum construction

• Perfect for retrofit installation to solve existing

noise problems

• Low-weight construction ideal for roof or

bridge mounted applications

• Designed to withstand high wind loads

All-Weather Applications

• Barrier modules are designed and built to minimize water

invasion

• Panels resist “wicking” moisture through the bottom and

are self-draining

• Exterior finishes resist harsh cleaners, common

chemicals and salt exposure

• Polyester powder coating

H/P 42 23 31 40 49 56 62 42

H/H 50 26 44 50 54 57 64 50

H/H 52 37 43 47 53 54 57 52

All tests performed by Riverbank Acoustical Laboratories, an independent NVLAP accredited acoustical testing facility.

The test method conforms with ASTM Designations E90-99 or E90-02 and E413-87.

Sound Absorption Coefficients

1/3 Octave Band Center Frequency, Hz 125 250 500 1K 2K 4K NRC

Barrier Panels:

V-Stack Aluminum 0.89 1.23 1.18 1.08 1.06 0.95 0.95 (1.15)

V-Stack Steel 0.86 1.20 1.17 1.07 1.08 1.02 0.95 (1.15)

SL Barrier 0.92 1.15 1.22 1.13 1.08 1.04 0.95 (1.15)

H/P 42 0.68 1.06 1.12 1.08 1.03 0.98 0.95 (1.05)

2” thick Cladding Panels

NB-II Aluminum 0.27 0.63 1.09 1.06 1.04 1.03 0.95

NB-II 0.26 0.53 1.00 1.03 0.97 1.01 0.90

NB-II-B 0.35 0.63 1.08 1.12 0.94 0.77 0.95

NB-SII-B 0.47 0.65 0.96 1.03 0.94 0.76 0.90

4” thick Cladding Panels

NB-II Aluminum 0.87 1.26 1.18 1.04 1.08 1.00 0.95

NB-IV 0.78 1.10 1.19 1.04 1.02 0.81 0.95 (1.10)

NB-IV-B 0.70 1.08 1.15 1.05 1.05 1.01 0.95 (1.10)

NB-SIV-B 0.95 0.83 0.96 0.98 0.99 0.79 0.95

All tests performed by Riverbank Acoustical Laboratories, an independent NVLAP accredited acoustical testing facility. The test method Conforms with the requirements of

the ASTM Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method: ASTM C423-90a and E795-00.

The Bottom Line:

Our Noise Control Barriers

start performing the moment

they arrive on the job site.

Get in touch with us today

to discuss your QuietLine

Barrier needs.

Features:

• Lightweight

• Durable

• Galvanized, aluminum, or stainless

steel

• Two, four, or five-inch thicknesses

• Easy installation and removal

• Horizontal or vertical installation

• Self-draining

• Maximum acoustical performance

• All products independently tested

• (STC 37 & above, NRC 0.95 & above)

• 10 year warranty

• Weather resistant

• Graffiti resistant

• Unlimited color selection