Noise Barriers Product Reference Guide
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
QuietLine
TM
TRANSPORTATION
Barrier Wall Systems:
Absorptive noise control barriers provide maximum noise
reduction with lightweight modular panels and/or louvers.
The noise barrier system is easy to install and easy
to relocate. Panels and louvers are constructed of
galvanized steel or aluminum and finish painted
in a weather and salt resistant polyester powder
coating. The finish is also graffiti resistant and
cleanable.
Acoustic Performance Data
1/3 Octave Band Center Frequency, Hz 125 250 500 1K 2K 4K STC
Sound Transmission Loss Data, dB
V-Stack Aluminum 14 20 31 42 40 52 33
V-Stack Steel 22 26 35 45 47 48 38
SL Barrier 18 26 35 45 49 52 37
H/P 38 24 25 33 43 50 55 38
Free-Standing or Elevated Panel Construction
• Allows for maximum flexibility of design and utility on the
ground or on the rooftop
• One– or two-sided sound absorption
• Steel or aluminum construction
• Perfect for retrofit installation to solve existing
noise problems
• Low-weight construction ideal for roof or
bridge mounted applications
• Designed to withstand high wind loads
All-Weather Applications
• Barrier modules are designed and built to minimize water
invasion
• Panels resist “wicking” moisture through the bottom and
are self-draining
• Exterior finishes resist harsh cleaners, common
chemicals and salt exposure
• Polyester powder coating
H/P 42 23 31 40 49 56 62 42
H/H 50 26 44 50 54 57 64 50
H/H 52 37 43 47 53 54 57 52
All tests performed by Riverbank Acoustical Laboratories, an independent NVLAP accredited acoustical testing facility.
The test method conforms with ASTM Designations E90-99 or E90-02 and E413-87.
Sound Absorption Coefficients
1/3 Octave Band Center Frequency, Hz 125 250 500 1K 2K 4K NRC
Barrier Panels:
V-Stack Aluminum 0.89 1.23 1.18 1.08 1.06 0.95 0.95 (1.15)
V-Stack Steel 0.86 1.20 1.17 1.07 1.08 1.02 0.95 (1.15)
SL Barrier 0.92 1.15 1.22 1.13 1.08 1.04 0.95 (1.15)
H/P 42 0.68 1.06 1.12 1.08 1.03 0.98 0.95 (1.05)
2” thick Cladding Panels
NB-II Aluminum 0.27 0.63 1.09 1.06 1.04 1.03 0.95
NB-II 0.26 0.53 1.00 1.03 0.97 1.01 0.90
NB-II-B 0.35 0.63 1.08 1.12 0.94 0.77 0.95
NB-SII-B 0.47 0.65 0.96 1.03 0.94 0.76 0.90
4” thick Cladding Panels
NB-II Aluminum 0.87 1.26 1.18 1.04 1.08 1.00 0.95
NB-IV 0.78 1.10 1.19 1.04 1.02 0.81 0.95 (1.10)
NB-IV-B 0.70 1.08 1.15 1.05 1.05 1.01 0.95 (1.10)
NB-SIV-B 0.95 0.83 0.96 0.98 0.99 0.79 0.95
All tests performed by Riverbank Acoustical Laboratories, an independent NVLAP accredited acoustical testing facility. The test method Conforms with the requirements of
the ASTM Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method: ASTM C423-90a and E795-00.
The Bottom Line:
Our Noise Control Barriers
start performing the moment
they arrive on the job site.
Get in touch with us today
to discuss your QuietLine
Barrier needs.
Features:
• Lightweight
• Durable
• Galvanized, aluminum, or stainless
steel
• Two, four, or five-inch thicknesses
• Easy installation and removal
• Horizontal or vertical installation
• Self-draining
• Maximum acoustical performance
• All products independently tested
• (STC 37 & above, NRC 0.95 & above)
• 10 year warranty
• Weather resistant
• Graffiti resistant
• Unlimited color selection