HEAVY

MOBILE

EQUIPMENT

FIRE

SUPRESSION

SYSTEMS

Safety & Environmental Protection is Our Priority


Hard Working

Deserves Solid


Machinery

Engineering


FLUORINE

FREE

3 different extinguish agents

Liquid - Tiborex Absolute

Powder

Argon Gas

A large amount of fine liquid

agent droplets is sprayed through the

special patented nozzles forming a huge

cooling reaction surface. Thus, the fire will

be rapidly deprived of thermal energy,

resulting in rapid drop of temperature. The

cooling effect breaks down the reaction

needed to support combustion.

In addition, after all the extinguishant

has been dispensed, the

propellant Nitrogen gas from the patented

container will be discharged, resulting in a

hybrid suppression system, further ensuring

that no oxygen gets on to the surface.

fine-spray

LIQUID FIRES

Fuel,lubricant and hydraulic fluids

SOLID FIRES

Plastic,rubber,wood,sawdust,cables

ELECTRICAL FIRES

Electric cabinets

3


technology

Robustness of

German Technology

Spy - Thermo-pneumatic Detector

Pattented

Multiple temperature range

Sensitive to hidden fires

Robust and Precise

Stainless-Steel

Optic and Acoustic Alarm

Led Light

Acoustical Signalization

Test Button

Stainless Steel Container

Safe and Robust

Internal Activation System

No maintenance

Stainless-Steel

Fine Spray Nozzles

Patented

90ºAngle spray

Robust and Precise

Stainless-Steel

4


Single line system detection / extinguishing

No electricity

no electrical power in the system is needed

No pressure

Extinguish Agent

Tiborex Absolute

no pressure in all pipeline

Maintenance free

almost maintenance free, no parts need to be replaced for 5 years

Simple&Easy to install

both for new system or retrofit and in a limited and confined space.

Patented technology

Applicable temperature: -50°C to 80°C

Able to work in extreme adverse conditions

firespy

2 separate line system: detection / extinguishing

No electricity

no electrical power in the system is needed

No pressure

Extinguish Agent

Powder

no pressure in all pipeline

Maintenance free

almost maintenance free, no parts need to be replaced for 5 years

Simple&Easy to install

both for new system or retrofit and in a limited and confined space.

Patented technology

Applicable temperature: -55°C to 80°C

Able to work in extreme adverse conditions

Certified by DMT, VdS and others

Approved and recognized by leading

international heavymobile equipment

manufacturers and end-users

5


Extinguish Agent

Tiborex Absolute

Argon Gas

Single line system detection / extinguishing

No electricity

no electrical power in the system is needed

Low Maintenance

almost maintenance free, no parts need to be replaced for 5 years

Simple&Easy to install

both for new system or retrofit and in a limited and confined space.

Patented technology

Applicable temperature: -50°C to 80°C

Able to work in extreme adverse conditions

mining machine

heavy-duty trucks

tunnel boring machinery

construction equipment

agricultural machinery

forest equipment

rail machinery

cranes

yacht

bus

firespy

6


Perfect fit

installations

Driver Cabin

24VDC

Alarm

Manual Release

Left

Manual

Release

DN 15x1.5

CAT Dump Truck

DN 8x1

T 141ºC T 141ºC T 141ºC

Engine bay

Hydraulic

Release

E-Cable

1NO, 1NC

Right

Manual

Release

T 141ºC

DN 8x1

T 141ºC

DN 15x1.5

T 141ºC

KOMATSU Dump Truck

DN 15x1.5

Ground

Manual

Release

Front

Driver Cabin

24VDC

Alarm

Manual Release

Manual

Release

Ground

Right

DN 8x1

T 141ºC

Hydraulic

T 141ºC

T 141ºC T 141ºC

Engine bay

T 141ºC

DN 8x1

DN 15x1.5

Release

E-Cable

1NO, 1NC

DN 8x1

DN 15x1.5

7


Excavator / Drilling Machine

DN 8x1

Driver

Cabin

Manual

Release

DN 12x1

T 182ºC

E-Cable

1NC

DN 12x1

Engine bay

T 182ºC T 182ºC

Excavator / Drilling Machine

Manual

Release

T 182ºC T 182ºC

E-Cable

1NC

DN 8x1

DN 15x1.5

T 182ºC T 182ºC

10

8


Tailor-fitted

Systems

Protecfire develops

costum tailored size installs.

All projects are studied

before installation.

Underground Excavator

DN 8x1

Rear

Section

Manual

Release

Driver

Cabin

Manual

Release

DN 12x1

T 141ºC T 141ºC

DN 12x1

Engine bay

Excavator

Driver Cabin

DN 8x1

Manual

Release

DN 12x1

Manual

Release

DN 12x1 T 141ºC T 141ºC

3

Engine bay 45m

T 141ºC

T 141ºC DN 12x1 T 141ºC T 141ºC

Automatic Activation

DN 12x1

T 141ºC T 141ºC T 141ºC

9


Avoiding Serious Consequences

According to the insurance companies’ data, the majority of

mining and construction machinery fires start in the engine

compartment.

Major causes include short circuit resulting from worn wires,

broken fuel line, using inappropriate fuse and improper electrical

systems modification.

In addition, some human factors, such as improper or lack of

maintenance, very dirty engine, improper usage and over-running

operation will also result in spontaneous combustion of

the equipment.

10


Quality of

German Engineering

11


12


New extinguishing agent - Tiborex Absolute

Oxygen

fuel

Heat

3d fire extinguish

FLUORINE

FREE

TiboRex

A B S O L U T E

13

ultra-fast liquid agent

fluorine-free

biodegradable

non-corrosive

non-toxic

use at -50°C to 80°C ambient temperatures

surface blanketing / quenching effect


COMPARISON OF

FIRE EXTINGUISHING AGENTS

TiboRex

Absolute

Water Foam Wetting

Agent

Powder

Gas

Fast Temperature Reduction

Surface Blanketing

Quenching Effect

Fine-Spray Technology

Corrosion Behavior

Fluorine Free

Temperature Range -50ºc a +80ºc

Danger to Persons

+

+

+

+

+

+

+

+

-

-

-

+

-

+

-

+

-

+

+

-

-

-

-

-

-

+

-

+

-

-

-

-

-

-

-

-

-

-

+

-

-

-

+

-

+

+

-

-

Extinguish agents Comparison

TiboRex

A B S O L U T E

14


Headquarters

Subsidiaries

Distributors

Protecfire (Asia Pacific) Ltd

Asia Pacific Regional HQ

Park Avenue Changi

2 Changi Business Park Anvenue 1

Unit 02-00. Singapore 486015

Tel .. +65-68097110

Fax .. +65-68097299

Email:sales@protecfire.asia

Protecfire GmbH

Headquarters & Factory

Weidekamp 10 D-23558. Luebeck. Germany

Authorized Distributor

China Office

Unit 2, Building 8. Satellite Navigation IndustrialPark

Guan Xinxing Industrial Park, Langfang City

Hebei Province 065500.

China

Tel .. +86 316 5929119 (ext.808)

Fax .. +86 316 5922569

www.protecfirechina.com

art. 2020/10-mining-protecfireasia

www.protecfire.de

www.protecfirechina.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!