© Siemens <strong>2019</strong><br />

2<br />

LOGO! Logic Modules<br />

LOGO! basic and expansion modules<br />

SIPLUS LOGO! basic modules without display<br />

■ Overview<br />

• Basic variants optimized for costs<br />

• Interface for connecting expansion modules,<br />

up to 24 digital inputs, 16 (20) digital outputs,<br />

8 analog inputs and 2 (8) analog outputs can be addressed<br />

• With connection option for LOGO! TDE text display<br />

• All basic units with integrated web server<br />

• Same enclosure width as LOGO! 0BA6 (4 U)<br />

• All basic units with Ethernet interface for communication<br />

with LOGO!, SIMATIC Controllers, SIMATIC Panel and PC<br />

• Use of standard micro CF cards<br />

Note:<br />

SIPLUS extreme products are based on SIMATIC standard<br />

products. The contents listed here were adopted from the<br />

respective standard products. SIPLUS extreme specific<br />

information was added.<br />

■ Technical specifications<br />

Article number 6AG1052-2CC08-7BA0 6AG1052-2MD08-7BA0 6AG1052-2HB08-7BA0 6AG1052-2FB08-7BA0<br />

Based on 6ED1052-2CC08-0BA0 6ED1052-2MD08-0BA0 6ED1052-2HB08-0BA0 6ED1052-2FB08-0BA0<br />

SIPLUS LOGO! 24CEO SIPLUS LOGO! 12/24RCEO SIPLUS LOGO! 24RCEO SIPLUS LOGO! 230RCEO<br />

(AC)<br />

Ambient conditions<br />

Ambient temperature during<br />

operation<br />

•min.<br />

-40 °C; = Tmin;<br />

Startup @ -25 °C<br />

-40 °C; = Tmin;<br />

Startup @ -25 °C<br />

-40 °C; = Tmin;<br />

Startup @ -25 °C<br />

-40 °C; = Tmin;<br />

Startup @ -25 °C<br />

•max. 70 °C; Tmax; Tmax > +55 °C<br />

max. load 0.2 A per output<br />

• At cold restart, min. -25 °C; incl. condensation /<br />

frost permitted<br />

(no commissioning under<br />

condensation conditions)<br />

Ambient temperature during<br />

storage/transportation<br />

70 °C; Tmax; Tmax > +55 °C<br />

max. load 1 A per relay or<br />

max. load 3 A per relay and<br />

half the number of DIs<br />

(no adjacent points)<br />

-25 °C; incl. condensation /<br />

frost permitted<br />

(no commissioning under<br />

condensation conditions)<br />

70 °C; Tmax; Tmax > +55 °C<br />

max. load 1 A per relay or<br />

max. load 3 A per relay and<br />

half the number of DIs<br />

(no adjacent points)<br />

-25 °C; incl. condensation /<br />

frost permitted<br />

(no commissioning under<br />

condensation conditions)<br />

•min. -40 °C -40 °C -40 °C -40 °C<br />

•max. 70 °C 70 °C 70 °C 70 °C<br />

Altitude during operation relating to<br />

sea level<br />

• Installation altitude above sea level, 5000m 5000m 5000m 2000m<br />

max.<br />

• Ambient air temperature-barometric<br />

pressure-altitude<br />

Relative humidity<br />

• With condensation,<br />

tested in accordance<br />

with IEC 60068-2-38, max.<br />

Tmin ... Tmax at<br />

1 140 hPa ... 795 hPa<br />

(-1 000 m ... +2 000 m) //<br />

Tmin ... (Tmax - 10 K) at<br />

795 hPa ... 658 hPa<br />

(+2 000 m ... +3 500 m) //<br />

Tmin ... (Tmax -20 K) at<br />

658 hPa ... 540 hPa<br />

(+3 500 m ... +5 000 m)<br />

100 %; RH incl.<br />

condensation / frost (no<br />

commissioning in bedewed<br />

state), horizontal installation<br />

Tmin ... Tmax at<br />

1 140 hPa ... 795 hPa<br />

(-1 000 m ... +2 000 m) //<br />

Tmin ... (Tmax - 10 K) at<br />

795 hPa ... 658 hPa<br />

(+2 000 m ... +3 500 m) //<br />

Tmin ... (Tmax -20 K) at<br />

658 hPa ... 540 hPa<br />

(+3 500 m ... +5 000 m)<br />

100 %; RH incl.<br />

condensation / frost (no<br />

commissioning in bedewed<br />

state), horizontal installation<br />

Tmin ... Tmax at<br />

1 140 hPa ... 795 hPa<br />

(-1 000 m ... +2 000 m) //<br />

Tmin ... (Tmax - 10 K) at<br />

795 hPa ... 658 hPa<br />

(+2 000 m ... +3 500 m) //<br />

Tmin ... (Tmax -20 K) at<br />

658 hPa ... 540 hPa<br />

(+3 500 m ... +5 000 m)<br />

100 %; RH incl.<br />

condensation / frost (no<br />

commissioning in bedewed<br />

state), horizontal installation<br />

70 °C; Tmax; Tmax > +55 °C<br />

max. load 1 A per relay<br />

-25 °C; incl. condensation /<br />

frost permitted<br />

(no commissioning under<br />

condensation conditions)<br />

Tmin ... Tmax at<br />

1 140 hPa ... 795 hPa<br />

(-1 000 m ... +2 000 m)<br />

100 %; RH incl.<br />

condensation / frost (no<br />

commissioning in bedewed<br />

state), horizontal installation<br />

2/18 Siemens ST 70 · <strong>2019</strong>