Load Centers & Circuit Breakers<br />

SPEEDFAX TM<br />

1Section<br />

PL Series<br />

Load Center<br />

Generator<br />

Ready<br />

Load Center<br />

PN Plug-On<br />

Neutral Load<br />

Center<br />

C o n t e n t s<br />

Load Centers<br />

Catalog Numbering System 1-2<br />

Plug-On Neutral Load Centers 1-3<br />

Electronic Breakers and Surge Protection 1-4<br />

PN Series 1-Phase Plug-On Neutral Load Centers<br />

Features 1-5<br />

1-phase, 3-wire, 120/240 Volts AC Main Breaker/Convertible 1-6<br />

1-phase, 3-wire, 120/240 Volts AC Main Lug/Convertible 1-7<br />

SN Series 1-Phase Plug-On Neutral Load Centers<br />

Features 1-8<br />

1-phase, 3-wire, 120/240 Volts AC Main Breaker 1-9<br />

1-phase, 3-wire, 120/240 Volts AC Main Lug 1-10<br />

1-phase, 3-wire, 120/240 Volts AC Specialty Main Lug and Breakers 1-11<br />

PL and ES Series 3-Phase Load Centers<br />

Features 1-12<br />

PL Series Main Lug and Main Breakers 1-13<br />

PL Series Unassembled Load Centers 1-14<br />

ES Series Main Lug and Main Breakers 1-15<br />

EQ ® Load Centers, 300-400 Amp 1-16<br />

Generator Ready Load Centers 1-17<br />

Riser Panel Load Centers 1-18<br />

EQ ® Load Centers, Small Circuit and Circuit Breaker Enclosures 1-19 – 1-20<br />

Renovation Interiors 1-21<br />

Load Center Accessories 1-22 – 1-25<br />

Knockout Diagrams 1-26 – 1-30<br />

Load Center Cross Reference 1-31 – 1-39<br />

Circuit Breakers<br />

Arc-Fault and Ground-Fault Breakers 1-40<br />

Type QP, 1" Breakers 1-41<br />

Duplex, Triplex and Quadplex Plug-In Breakers 1-42<br />

Special Application Breakers 1-43<br />

Type QD, 3/4" Breakers 1-44<br />

Main and Branch Circuit Breakers 1-45<br />

Circuit Breaker Dimension Drawings and Lug Data 1-46 – 1-47<br />

Circuit Breaker Accessories 1-48 – 1-49<br />

Surge Protection Products 1-50 – 1-52<br />

AC Disconnects, 1-Phase, NEMA 3R Rated 1-53<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Scan to connect<br />

online to the<br />

most up-todate<br />

version of<br />

this Section of<br />

SPEEDFAX.<br />

(Section was last modified on 03/31/20)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-1


Load Centers<br />

Revised on 03/31/20<br />

Catalog Numbering System<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Catalog Numbering System<br />

­<br />

Type Enclosure or Component<br />

PN = Plug-On Neutral PN Series Indoor Type 1<br />

SN = Plug-On Neutral SN Series Indoor Type 1<br />

PNW = Plug-On Neutral PN Series Outdoor Type 3R<br />

SNW = Plug-On Neutral SN Series Outdoor Type 3R<br />

E = Indoor Type 1 2-10 and 30-42 circuits 300-400Amp<br />

G = Indoor Type 1 12-42 circuits<br />

W = Outdoor Type 3R<br />

I or PI = Interior<br />

R = Riser<br />

P = PL Series Indoor Type 1 12-70 circuits<br />

S = ES Series Indoor Type 1 12-70 circuits<br />

PW = PL Series Outdoor Type 3R 12-70 circuits<br />

SW = ES Series Outdoor Type 3R 12-70 circuits<br />

Spaces<br />

Maximum number of 1" breakers<br />

Circuits<br />

Maximum number of circuits<br />

Type of Main<br />

ML or L = Main Lug<br />

MB or B = Main Breaker<br />

System<br />

1 = 1-Phase, 3-Wire<br />

3 = 3-Phase, 3-Wire or<br />

3-Phase, 4-Wire<br />

Main Ampere Rating<br />

Ex:100 = 100 Amps<br />

Interior<br />

Blank<br />

A<br />

= Standard<br />

= Wireguide<br />

Trim/Others<br />

Blank = Combination<br />

S = Surface<br />

F = Flush<br />

T = Feed-Thru Lugs<br />

G or GB = Ground Bar Factory Installed<br />

Type of Bus Bar<br />

Blank<br />

C or CU<br />

P<br />

Trim Color<br />

Blank = Grey<br />

W = White<br />

= Aluminum<br />

= Copper<br />

= Aluminum Bus, Value Pack<br />

P 12 24 B 1 100 A S CU W<br />

Products Shown In Sections 1 of this <strong>Speedfax</strong><br />

Meet or Exceed the Following Standards.<br />

n UL50 — Electric Cabinets and Boxes<br />

n UL67 — Electric Panelboards<br />

n UL486 — Wire Connectors<br />

n UL489 — Molded-Case Circuit Breakers<br />

n UL869 — Service Equipment<br />

n UL943 — Ground Fault interrupters<br />

(Class A — Personnel Protection)<br />

n Federal Specification W-P-115b —<br />

Panel Power Distribution<br />

n Federal Specification W-C-375B —<br />

Circuit Breakers<br />

n NEC<br />

n NEMA 250<br />

Underwriters’ Laboratories, Inc.<br />

Reference File Numbers:<br />

n Series Connected Circuit Breaker Information is<br />

recognized by UL under file #E10848(N)<br />

n Load Centers Listed by UL under file #E10703<br />

n Load Centers UL recognized components found<br />

under file #E10703, Volume 6 and 7. (Also<br />

referenced under the recognized components<br />

directory — section QEUY2)<br />

n EQ Circuit Breakers are Listed by UL under file<br />

#E82615<br />

1-2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Plug-On Neutral Load Centers<br />

Revised on 03/31/20<br />

Overview<br />

Plug-On Neutral Load Centers<br />

You have come to know Siemens solutions for their durability,<br />

innovation, and safety attributes. This continues with the<br />

plug-on neutral load center with electronic breakers to provide<br />

a more secure connection resulting in a more confident<br />

installation.<br />

With an overall smaller electronic breaker footprint, the plugon<br />

neutral load center still gives you over 4” of wire bending<br />

space, which allows for a simpler, cleaner, and faster path to<br />

a finished project.<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Simple<br />

n Quicker breaker installation<br />

n Wiring made easier with the neutral lug removed on CAFCI breakers<br />

n Same great features as PL and ES load centers<br />

Spacious<br />

n Small electronic breaker footprint<br />

n Design allows for neutral terminal accessibility<br />

n Over 4 inches of wire bending space<br />

Secure<br />

n Same reliable installation method<br />

n Neutral clip is the same as line side<br />

n Durable hook-rail<br />

A Siemens Advantage<br />

The plug-on neutral load center has the same great features of the<br />

PL and ES line, plus an integrated neutral bus. a<br />

Convertible<br />

Bonding Screw<br />

Visible Neutrals<br />

Insta-Wire<br />

Invertible<br />

Durable Hook-Rails<br />

Integrated<br />

Neutral Bus<br />

a PN panels are convertible and come with two ground<br />

bars. SN panels come with one ground bar.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-3


Electronic Breakers and Surge Protection<br />

Revised on 03/31/20<br />

Complete Offering<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Electronic Breakers and Surge Protection<br />

The new plug-on neutral load center is compatible<br />

with existing surge solutions including the QSA<br />

breaker and FirstSurge stand-alone units.<br />

Additionally, there are four panels offered with a<br />

factory-installed FirstSurge unit.<br />

For more information on the Surge Protection<br />

product line, see Section 10 and Section 7<br />

Page 7-28 of the <strong>Speedfax</strong> at<br />

usa.siemens.com/speedfax.<br />

FirstSurge<br />

Surge Protection Device<br />

QSA Circuit Breaker and<br />

Surge Protection Device<br />

2-Pole<br />

Combination Type AFCI<br />

1-Pole<br />

GFCI<br />

1-Pole<br />

Combination Type AFCI<br />

1-Pole<br />

Dual Function<br />

Plug-on neutral breaker offering:<br />

• 1 and 2-pole CAFCI<br />

• 1-pole Dual Function (CAFCI/GFCI)<br />

• 1-pole GFCI<br />

Features:<br />

• Load Lug(s) only on the CAFCI breakers<br />

• LED indicators for troubleshooting<br />

• Insta-Wire connectors<br />

Technical Data:<br />

• 10,000 AIC<br />

• 120V<br />

• UL Listed<br />

• HACR and SWD rated<br />

AFCI<br />

Dual<br />

Function<br />

GFCI (5mA)<br />

Breaker Type<br />

QAF2N<br />

Plug-on Neutral<br />

1-Pole 120V AC<br />

QAF2N<br />

Plug-on Neutral<br />

2-Pole 120/240V AC<br />

QFGA2N<br />

Plug-on Neutral<br />

1-Pole 120V AC<br />

QPF2N<br />

Plug-on Neutral<br />

1-Pole 120V AC<br />

Ampere<br />

Rating<br />

10,000 A IR<br />

Catalog No.<br />

15 QA115AFCN<br />

20 QA120AFCN<br />

15 Q215AFCN<br />

20 Q220AFCN<br />

15 Q115DFN<br />

20 Q120DFN<br />

15 QF115AN<br />

20 QF120AN<br />

30 QF130AN<br />

Note: Both plug-on neutral and existing pigtail breakers are listed for use in plug-on<br />

neutral load centers. For information on the complete product line, go to page 25.<br />

1-4<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


PN Series 1-Phase Plug-On Neutral Load Centers<br />

Revised on 03/31/20<br />

Features<br />

n Convertible<br />

n Invertible<br />

n Bonding Screw<br />

n Visible Neutrals<br />

All devices<br />

are provided<br />

with 2 factory<br />

installed<br />

ground bars.<br />

n Insta-Wire<br />

n Durable Hook-Rails<br />

n Integrated Neutral Bus<br />

n Extended Lifetime Warranty<br />

Invertible for bottom<br />

feed application. a<br />

All devices convertible<br />

from main lug to main<br />

breaker and vice versa.<br />

Mounting tabs<br />

on the trim<br />

hold it in place<br />

on the load<br />

center, freeing<br />

up both hands<br />

to drive the<br />

trim screws.<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Combination<br />

head screw on<br />

the neutrals,<br />

ground, trim,<br />

upper pan,<br />

and bond<br />

screw provide<br />

installation<br />

flexibility.<br />

A rigid, sturdy<br />

base pan<br />

provides the<br />

ruggedness<br />

required<br />

for the<br />

most harsh<br />

applications.<br />

The prepositioned<br />

bond screw<br />

eliminates<br />

bond strap/<br />

screw<br />

assemblies,<br />

and reduces<br />

the risk of<br />

losing components in the field.<br />

The patented<br />

INSTA-WIRE<br />

neutral/ground<br />

system allows<br />

for faster<br />

installation<br />

because<br />

screws are<br />

backed out,<br />

ready for wire insertion. The visible<br />

neutral and grounds system aids in<br />

the insertion of conductors.<br />

Copper Bus b<br />

All devices come with an<br />

integrated neutral bus.<br />

1-Phase PN Series Plug-On<br />

Neutral Load Centers ship with<br />

trims packaged separately.<br />

The outdoor enclosure has a<br />

slide hinge door for the easiest<br />

installation and can be removed<br />

by backing out only one screw.<br />

a Applies only to NEMA 1 PN and SN plug-on neutral load centers.<br />

b PN SKUs that have a C suffix have copper bus.<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-5


PN Series 1-Phase Plug-On Neutral Load Centers<br />

Revised on 03/31/20<br />

1-phase, 3-wire, 120/240 Volts AC Main Breaker/Convertible<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Main Breaker/Convertible Load Centers <br />

100-225 Amperes<br />

Indoor Enclosure - NEMA Type 1<br />

Copper Bus<br />

60/75°C Rated<br />

Outdoor Enclosure - NEMA Type 3R<br />

Amp<br />

Rating<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits Catalog Number f<br />

Enclosure Height<br />

(inches) b Catalog Number<br />

Enclosure Height<br />

(inches) c<br />

100 12 24 PN1224B1100C 18 PNW1224B1100C 21<br />

100 16 32 PN1632B1100C 21 PNW1632B1100C 23<br />

100 20 20 PN2020B1100C 21 PNW2020B1100C 27<br />

100 20 40 PN2040B1100C 21 — —<br />

100 24 24 PN2424B1100C 24 — —<br />

100 30 30 PN3030B1100C 26 — —<br />

100 30 48 — — PNW3048B1100C 29<br />

125 30 30 PN3030B1125C 26 — —<br />

125 30 48 — — PNW3048B1125C 29<br />

150 8 16 — — PNW0816B1150TC e 23<br />

150 20 40 PN2040B1150C 24 PNW2040B1150C 27<br />

150 30 30 PN3030B1150C 30 — —<br />

150 30 48 — — PNW3048B1150C 35<br />

200 8 16 — — PNW0816B1200TC e 23<br />

200 20 40 PN2040B1200C 26 PNW2040B1200C 27<br />

200 30 48 PN3048B1200 d 30 — —<br />

200 30 48 PN3048B1200C 30 PNW3048B1200C 35<br />

200 40 40 PN4040B1200 d 36 — —<br />

200 40 40 PN4040B1200C 36 PNW4040B1200C 38<br />

200 40 60 PN4060B1200 d 36 — —<br />

200 40 60 PN4060B1200C 36 — —<br />

200 54 82 PN5482B1200C 42 — —<br />

225 42 64 PN4264B1225C 39 PNW4264B1225C 38<br />

225 54 82 PN5482B1225C 43 — —<br />

a Factory installed 22KAIC main breaker. Suitable for use<br />

as service equipment.<br />

b Indoor enclosures are 14 1/4” wide by 3 7/8” deep.<br />

c Outdoor enclosures are 14 1/2” wide by 4 1/4” deep.<br />

d Includes all PN series features with aluminum bus.<br />

e Feed-thru lugs.<br />

f Available (made to order) in white by adding "W" to the<br />

end of the catalog number.<br />

1-6<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


PN Series 1-Phase Plug-On Neutral Load Centers<br />

Revised on 03/31/20<br />

1-phase, 3-wire, 120/240 Volts AC Main Lug/Convertible<br />

Main Lug/Convertible Load Centers c<br />

125-225 Amperes<br />

Indoor Enclosure - NEMA Type 1<br />

Copper Bus<br />

60/75°C Rated<br />

Outdoor Enclosure - NEMA Type 3R<br />

Amp Rating<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits Catalog Number f<br />

Enclosure Height<br />

(inches) a Catalog Number<br />

Enclosure Height<br />

(inches) b<br />

125 12 12 PN1212L1125C 18 PNW1212L1125C 21<br />

125 12 24 PN1224L1125C 18 PNW1224L1125C 21<br />

125 16 32 PN1632L1125C 21 PNW1632L1125C 23<br />

125 20 20 PN2020L1125C 21 — —<br />

125 20 40 PN2040L1125C 21 — —<br />

125 24 48 PN2448L1125C 24 — —<br />

125 30 48 PN3048L1125C 26 PNW3048L1125C 29<br />

125 40 40 PN4040L1125C 36 — —<br />

150 20 40 PN2040L1150C 24 PNW2040L1150C 27<br />

200 8 16 — — PNW0816L1200TC e 23<br />

200 12 24 PN1224L1200C 21 PNW1224L1200C 23<br />

200 20 40 PN2040L1200C 26 PNW2040L1200C 27<br />

200 24 48 PN2448L1200C 30 — —<br />

200 30 30 PN3030L1200C 30 — —<br />

200 30 48 PN3048L1200 d 30 — —<br />

200 30 48 PN3048L1200C 30 PNW3048L1200C 35<br />

200 40 40 PN4040L1200 d 36 — —<br />

200 40 40 PN4040L1200C 36 PNW4040L1200C 38<br />

200 40 60 PN4060L1200C 36 — —<br />

225 12 24 — — PNW1224L1225C 27<br />

225 42 64 PN4264L1225C 39 PNW4264L1225C 38<br />

225 54 82 PN5482L1225C 43 — —<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

a Indoor enclosures are 14 1/4” wide by 3 7/8” deep.<br />

b Outdoor enclosures are 14 1/2” wide by 4 1/4” deep.<br />

c 125A load centers will accept MBK100A and MBK125A.<br />

150A load centers will accept MBK150A. 200A load<br />

centers will accept MBK200A and MBK150A. 225A load<br />

centers will accept MBK225A, MBK200A, MBK150A.<br />

d Includes all PN series features with aluminum bus.<br />

e Feed-thru lugs.<br />

f Available (made to order) in white by adding "W" to the<br />

end of the catalog number.<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-7


SN Series 1-Phase Plug-On Neutral Load Centers<br />

Revised on 03/31/20<br />

Features<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

n Invertible<br />

n Bonding Screw<br />

n Visible Neutrals<br />

n Insta-Wire<br />

SN Series<br />

Plug-On<br />

Neutral Load<br />

Centers<br />

come with<br />

one factory<br />

installed<br />

ground bar<br />

Combination<br />

head screw on<br />

the neutrals,<br />

ground, trim,<br />

upper pan,<br />

and bond<br />

screw provide<br />

installation<br />

flexibility.<br />

A rigid, sturdy<br />

base pan<br />

provides the<br />

ruggedness<br />

required<br />

for the<br />

most harsh<br />

applications.<br />

n Durable Hook-Rails<br />

n Integrated Neutral Bus<br />

n Extended 10-Year Warranty<br />

Invertible for bottom<br />

feed application. a<br />

All devices come with an<br />

integrated neutral bus<br />

Mounting tabs<br />

on the trim<br />

hold it in place<br />

on the load<br />

center, freeing<br />

up both hands<br />

to drive the<br />

trim screws.<br />

The prepositioned<br />

bond screw<br />

eliminates<br />

bond strap/<br />

screw<br />

assemblies,<br />

and reduces<br />

the risk of<br />

losing components in the field.<br />

The patented<br />

INSTA-WIRE<br />

neutral/ground<br />

system allows<br />

for faster<br />

installation<br />

because<br />

screws are<br />

backed out,<br />

ready for wire insertion. The visible<br />

neutral and grounds system aids in<br />

the insertion of conductors.<br />

Aluminum<br />

Bus<br />

a Applies only to NEMA 1 PN and SN plug-on<br />

neutral load centers<br />

The outdoor enclosure has a<br />

slide hinge door for the easiest<br />

installation and can be removed<br />

by backing out only one screw.<br />

1-8<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


SN Series 1-Phase Plug-On Neutral Load Centers<br />

Revised on 03/31/20<br />

1-phase, 3-wire, 120/240 Volts AC Main Breaker<br />

Main Breaker Load Centers a<br />

100-225 Amperes<br />

Indoor Enclosure - NEMA Type 1<br />

Aluminum Bus<br />

60/75°C Rated<br />

Outdoor Enclosure - NEMA Type 3R<br />

Amp<br />

Rating<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits Catalog Number e<br />

Enclosure Height<br />

(inches) b Catalog Number<br />

Enclosure Height<br />

(inches) c<br />

100 12 24 SN1224B1100 18 SNW1224B1100 21<br />

100 16 32 SN1632B1100 21 SNW1632B1100 23<br />

100 20 20 SN2020B1100 21 SNW2020B1100 27<br />

100 20 40 SN2040B1100 21 — —<br />

100 24 48 SN2448B1100 24 — —<br />

100 30 30 SN3030B1100 26 — —<br />

100 30 48 SN3048B1100 26 — —<br />

125 12 24 — — SNW1224B1125 21<br />

125 16 32 SN1632B1125 21 — —<br />

125 20 40 — — SNW2040B1125 27<br />

125 24 24 SN2424B1125 24 SNW2424B1125 27<br />

125 30 30 SN3030B1125 26 — —<br />

125 30 48 SN3048B1125 26 SNW3048B1125 29<br />

150 16 32 SN1632B1150 24 — —<br />

150 20 40 SN2040B1150 24 SNW2040B1150 27<br />

150 24 48 SN2448B1150 26 — —<br />

150 30 30 SN3030B1150 30 — —<br />

150 30 48 SN3048B1150 30 SNW3048B1150 35<br />

200 40 40 — — SNW4040B1150 38<br />

200 8 16 — — SNW0816B1200T d 23<br />

200 12 24 — — SNW1224B1200 23<br />

200 16 32 SN1632B1200 24 — —<br />

200 20 40 SN2040B1200 26 SNW2040B1200 27<br />

200 24 48 SN2448B1200 30 — —<br />

200 30 48 SN3048B1200 30 SNW3048B1200 35<br />

200 40 40 SN4040B1200 36 SNW4040B1200 38<br />

200 40 60 SN4060B1200 36 — —<br />

200 42 64 SN4264B1200 39 — —<br />

200 54 82 SN5482B1200 42 — —<br />

225 42 64 SN4264B1225 39 SNW4264B1225 38<br />

225 54 82 SN5482B1225 43 — —<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

a Factory installed 22KAIC main breaker. Suitable for use<br />

as service equipment.<br />

b Indoor enclosures are 14 1/4” wide by 3 7/8” deep.<br />

c Outdoor enclosures are 14 1/2” wide by 4 1/4” deep.<br />

d Feed-thru lugs.<br />

e Available (made to order) in white by adding “W” to<br />

the end of the catalog number.<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-9


SN Series 1-Phase Plug-On Neutral Load Centers<br />

Revised on 03/31/20<br />

1-phase, 3-wire, 120/240 Volts AC Main Lug<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Main Lug Load Centers<br />

100-225 Amperes<br />

Indoor Enclosure - NEMA Type 1<br />

Aluminum Bus<br />

60/75°C Rated<br />

Outdoor Enclosure - NEMA Type 3R<br />

Amp<br />

Rating<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits Catalog Number d<br />

Enclosure Height<br />

(inches) a Catalog Number<br />

Enclosure Height<br />

(inches) b<br />

125 12 12 SN1212L1125 18 SNW1212L1125 21<br />

125 12 24 SN1224L1125 18 SNW1224L1125 21<br />

125 16 32 SN1632L1125 21 SNW1632L1125 21<br />

125 20 20 SN2020L1125 21 — —<br />

125 20 40 SN2040L1125 21 SNW2040L1125 23<br />

125 24 24 SN2424L1125 24 SNW2424L1125 27<br />

125 24 48 SN2448L1125 24 — —<br />

125 30 48 SN3048L1125 26 SNW3048L1125 29<br />

125 40 40 SN4040L1125 30 — —<br />

150 16 32 SN1632L1150 21 — —<br />

150 20 40 SN2040L1150 24 SNW2040L1150 27<br />

150 24 48 SN2448L1150 26 — —<br />

200 8 16 — — SNW0816L1200T c 23<br />

200 12 24 SN1224L1200 21 SNW1224L1200 21<br />

200 20 40 SN2040L1200 26 SNW2040L1200 27<br />

200 24 48 SN2448L1200 26 — —<br />

200 30 30 SN3030L1200 30 — —<br />

200 30 48 SN3048L1200 30 SNW3048L1200 29<br />

200 40 40 SN4040L1200 36 SNW4040L1200 35<br />

225 12 24 — — SNW1224L1225 21<br />

225 40 60 SN4060L1225 36 — —<br />

225 42 64 SN4264L1225 36 SNW4264L1225 38<br />

225 54 82 SN5482L1225 42 — —<br />

a Indoor enclosures are 14 1/4” wide by 3 7/8” deep.<br />

b Outdoor enclosures are 14 1/2” wide by 4 1/4” deep.<br />

c Feed-thru lugs.<br />

d Available (made to order) in white by adding “W” to<br />

the end of the catalog number.<br />

1-10<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Specialty Main Lug and Main Breaker Plug-On Neutral Load Centers<br />

1-phase, 3-wire, 120/240 Volts AC<br />

Revised on 03/31/20<br />

Factory Installed FirstSurge Load Centers aef<br />

Amp<br />

Rating<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits<br />

Indoor Enclosure – NEMA Type 1<br />

Enclosure Height b<br />

Catalog Number<br />

(inches)<br />

200 30 48 PN3048B1200S14 36 140kA<br />

200 40 60 PN4060B1200S14 42 140kA<br />

200 30 48 SN3048B1200S06 36 60kA<br />

Surge Protection<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

200 40 60 SN4060B1200S06 42 60kA<br />

500 Kcmil Lug Load Center af<br />

Amp No. of No. of<br />

Indoor Enclosure – NEMA Type 1<br />

Enclosure Height b<br />

Rating Spaces Circuits Catalog Number<br />

(inches)<br />

200 30 48 SN3048L1200L50 36<br />

Selectable Main Load Centers df<br />

Amp<br />

Rating<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits<br />

Indoor Enclosure – NEMA Type 1<br />

Catalog Number<br />

Enclosure Height b<br />

(inches)<br />

Outdoor Enclosure – NEMA Type 3R<br />

Catalog Number<br />

125 24 24 SN2424C1125 24 SNW2424C1125 27<br />

200 20 40 SN2040C1200 26 SNW2040C1200 27<br />

200 30 48 SN3048C1200 30 SNW3048C1200 35<br />

200 40 40 SN4040C1200 36 SNW4040C1200 38<br />

Enclosure Height c<br />

(inches)<br />

a Factory installed 22KAIC main breaker. Suitable for use<br />

as service equipment.<br />

b Indoor enclosures are 14 1/4” wide by 3 7/8” deep.<br />

c Outdoor enclosures are 14 1/2” wide by 4 1/4” deep.<br />

d Selectable main load centers do not come with main<br />

lugs or main breakers. Those kits are sold separately.<br />

e PN has Copper bus<br />

f SN has Aluminum Bus<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-11


PL and ES Series 3-Phase Load Centers<br />

Revised on 03/31/20<br />

Features<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

PL Series:<br />

n Convertible<br />

n Invertible<br />

n Flush or Surface Mount Combination Cover<br />

n Insta-wire neutrals & grounds<br />

n Ground bars included<br />

n Copper busbars<br />

n Dual neutrals on all configurations<br />

n Carton-in-carton packaging<br />

n Lifetime warranty<br />

ES Series:<br />

n Invertible<br />

n Flush or Surface Mount Combination Cover<br />

n Insta-wire neutrals & grounds<br />

n Aluminum busbars<br />

n Single sided neutral on 24 circuits<br />

and below<br />

n Single piece carton packaging<br />

n 10 year warranty<br />

PL Series 3-phase<br />

ES Series 3-phase<br />

1-12<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


PL Series 3-Phase Main Lug & Main Breaker Load Centers<br />

3-phase, 3-wire, 240 Volt AC or 3-phase, 4-wire, 120/240 or 120/208 Volts AC<br />

Revised on 03/31/20<br />

Main Breaker/Convertible Load Centers<br />

30-70 Circuits / 100-225 Amperes<br />

Copper Bus g<br />

60/75°C Rated 22,000A IR a<br />

Branch Circuits Indoor Enclosure – NEMA Type 1 Outdoor Enclosure – NEMA Type 3R<br />

Amp<br />

Rating<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits Catalog Number<br />

Enclosure Height<br />

(inches) c Catalog Number<br />

100 12 24 P1224B3100CU b 24 — —<br />

100 30 42 P3042B3100CU b 30 — —<br />

125 30 30 P3030B3125CU 39 — —<br />

150 24 42 P2442B3150CU 36 — —<br />

150 42 42 P4242B3150CU 42 — —<br />

200 30 54 P3054B3200CU 39 PW3054B3200CU 38<br />

200 42 60 P4260B3200CU i 42 PW4260B3200CU 42<br />

225 42 60 P4260B3225CU 42 — —<br />

225 42 60 P4260B3225TCU e 49 — —<br />

225 54 70 P5470B3225CU 49 — —<br />

Enclosure Height<br />

(inches) d<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Main Lug/Convertible Load Centers<br />

12-70 Circuits / 125-225 Amperes<br />

Copper Bus g<br />

60/75° Rated 100,000A IR h<br />

Branch Circuits Indoor Enclosure – NEMA Type 1 Outdoor Enclosure – NEMA Type 3R<br />

Amp<br />

Rating<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits Catalog Number<br />

Enclosure Height<br />

(inches) c Catalog Number<br />

125 12 24 P1224L3125CU f 21 PW1224L3125CU f 21<br />

200 24 42 P2442L3200CU 36 PW2442L3200CU 35<br />

200 30 54 P3054L3200CU 39 PW3054L3200CU 38<br />

225 42 60 P4260L3225CU 42 PW4260L3225CU 42<br />

225 54 70 P5470L3225CU 49 — —<br />

Enclosure Height<br />

(inches) d<br />

a May be installed on higher rated systems when protected<br />

by a circuit breaker with a higher AIR rating.<br />

b Back fed main breaker.<br />

c Indoor enclosures are 14 1/4" wide by 3 7/8" deep.<br />

d Outdoor enclosures are 14 1/2" wide by 4 1/4" deep.<br />

e Includes factory installed feed through lugs and is also nonconvertible.<br />

f Non-convertible to main breaker.<br />

g All load centers are provided with tin plated copper bus bars.<br />

h Rated 100,000A IR in series with breakers listed on<br />

wiring diagram.<br />

i Available (made to order) in white by adding "W" to the end<br />

of the part number<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-13


PL Series 3-Phase Unassembled Load Centers<br />

Revised on 03/31/20<br />

3-phase, 3-wire, 240 Volt AC or 3-phase, 4-wire, 120/240 or 120/208 Volts AC<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

1<br />

Main Breaker Convertible Unassembled Load Centers<br />

24-70 Circuits / 100-225 Amperes<br />

Interiors Enclosure Trim Kit<br />

Amp<br />

Rating<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits<br />

Interior<br />

Catalog Number<br />

Enclosure Height<br />

(inches) c<br />

Enclosure<br />

Catalog Number<br />

Copper Bus e<br />

60/75°C Rated 22,000A IR a<br />

No. Breaker<br />

Spaces<br />

Trim<br />

Catalog Number d<br />

100 30 42 PI3042B3100CU b 30 3PE30 30 PT3042B3100<br />

150 24 42 PI2442B3150CU 36 3PE36 24 PT2442X3150<br />

200 30 54 PI3054B3200CU 39 3PE39 30 PT3054X3200<br />

200 42 60 PI4260B3200CU 42 3PE42 42 PT4260X3200<br />

225 54 70 PI5470B3225CU 49 3PE49 54 PT5470X3225<br />

Main Lug Convertible Unassembled Load Centers<br />

Copper Bus e<br />

12-70 Circuits / 125-225 Amperes<br />

60/75° Rated 100,000A IR f<br />

Interiors Enclosure Trim Kit<br />

Amp<br />

Rating<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits<br />

Interior<br />

Catalog Number<br />

Enclosure Height<br />

(inches) c<br />

Enclosure<br />

Catalog Number<br />

No. Breaker<br />

Spaces<br />

Trim<br />

Catalog Number d<br />

125 12 24 PI1224L3125CU 21 3PE21 12 PT1224L3125<br />

200 24 42 PI2442L3200CU 36 3PE36 24 PT2442X3200<br />

200 30 54 PI3054L3200CU 39 3PE39 30 PT3054X3200<br />

225 42 60 PI4260L3225CU 42 3PE42 42 PT4260X3225<br />

225 54 70 PI5470L3225CU 49 3PE49 54 PT5470X3225<br />

a May be installed on higher rated systems when<br />

protected by a circuit breaker with a higher AIR rating.<br />

b Back fed main breaker.<br />

c Indoor enclosures are 14 1/4" wide by 3 7/8" deep.<br />

d Trim catalog numbers with a “B” indicate for use with<br />

main breaker and is not convertible. “L” indicates for<br />

use with main lug and is not convertible. “X” indicates<br />

can be used with convertible interior.<br />

e All load center interiors are provided with tin plated<br />

copper bus bars.<br />

f Rated 100,000A IR in series with breakers listed on<br />

wiring diagram.<br />

1-14<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


ES Series 3-Phase Main Lug & Main Breaker Load Centers<br />

3-Phase, 3-Wire, 240 Volt AC or 3-Phase, 4-Wire, 120/240 or 120/208 Volts AC<br />

Revised on 03/31/20<br />

Main Breaker<br />

30-60 Circuits / 100-225 Amperes<br />

Aluminum Bus<br />

60/75°C Rated 10,000A IR a<br />

Branch Circuits Indoor Enclosure – NEMA Type 1 Outdoor Enclosure – NEMA Type 3R<br />

Amp<br />

Rating<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits Catalog Number<br />

Enclosure Height<br />

(inches) c Catalog Number<br />

100 12 24 S1224B3100 b 24 SW1224B3100 23<br />

100 30 30 S3030B3100 b 30 — —<br />

100 30 42 S3042B3100 b 30 — —<br />

125 30 42 S3042B3125 35 — —<br />

150 24 42 S2442B3150 36 SW2442B3150 35<br />

150 42 42 S4242B3150 42 — —<br />

150 30 54 S3054B3150 35 — —<br />

200 30 54 S3054B3200 39 SW3054B3200 38<br />

200 42 60 S4260B3200 42 SW4260B3200 42<br />

225 42 42 S4242B3225 42 SW4242B3225 42<br />

Enclosure Height<br />

(inches) d<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Main Lug<br />

12-70 Circuits / 125-225 Amperes<br />

Aluminum Bus<br />

60/75° Rated 100,000A IR e<br />

Branch Circuits Indoor Enclosure – NEMA Type 1 Outdoor Enclosure – NEMA Type 3R<br />

Amp<br />

Rating<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits Catalog Number<br />

Enclosure Height<br />

(inches) c<br />

Catalog Number<br />

125 12 24 S1224L3125 21 SW1224L3125 21<br />

150 18 36 S1836L3150 24 SW1836L3150 23<br />

150 24 42 S2442L3150 30 SW2442L3150 27<br />

200 12 24 S1224L3200 21 SW1224L3200 21<br />

200 24 42 S2442L3200 30 SW2442L3200 27<br />

200 30 54 S3054L3200 f 30 SW3054L3200 35<br />

225 42 60 S4260L3225 f 36 SW4260L3225 38<br />

225 54 70 S5470L3225 f 42 — —<br />

Enclosure Height<br />

(inches) d<br />

a May be installed on higher rated systems when<br />

protected by a circuit breaker with a higher AIR rating.<br />

b Back fed main breaker.<br />

c Indoor enclosures are 14 1/4" wide by 3 7/8" deep.<br />

d Outdoor enclosures are 14 1/2" wide by 4 1/4" deep.<br />

e Rated 100,000A IR in series with breakers listed on<br />

wiring diagram.<br />

f Available (made to order) in white by adding "W" to the<br />

end of the part number.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-15


EQ ® Load Centers—300-400 Amp<br />

Revised on 03/31/20<br />

1-Phase, 3-Wire/3-Phase, 3-Wire, 4-Wire<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Features<br />

n UL listed for 60/75°C conductors.<br />

See equipment markings for applications.<br />

n Copper bus standard.<br />

n Factory installed lock on indoor enclosures.<br />

n Main breaker units have a factory installed<br />

JXD2 type breaker.<br />

E3030MB1400SCU<br />

Main Breaker 300-400 Ampere b<br />

1Ø, 3-Wire<br />

120/240 Volts AC<br />

65,000A IR<br />

Branch Circuits Indoor Enclosure – NEMA Type 1 Outdoor Enclosure – NEMA Type 3R<br />

Amp<br />

Rating<br />

300<br />

400<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits Catalog Number<br />

Enclosure<br />

Height a Trim Style Catalog Number<br />

Enclosure<br />

Height a<br />

42 42 E4242MB1300FCU 58 Flush — —<br />

42 42 E4242MB1300SCU 58 Surface — —<br />

30 30 — 47 Surface — —<br />

30 30 E3030MB1400SCU 52 Surface W3030MB1400CU 52<br />

42 42 E4242MB1400FCU 58 Flush — —<br />

42 42 E4242MB1400SCU 58 Surface W4242MB1400CU 58<br />

240 Volts AC<br />

3Ø, 3-Wire, 4-Wire<br />

65,000A IR<br />

Branch Circuits Indoor Enclosure – NEMA Type 1 Outdoor Enclosure – NEMA Type 3R<br />

Amp Rating No. of Spaces No. of Circuits Catalog Number<br />

Enclosure<br />

Height a Trim Style Catalog Number<br />

Enclosure<br />

Height a<br />

300 42 42 E4242MB3300SCU 58 Surface — —<br />

30 30 E3030MB3400SCU 52 Surface — —<br />

400<br />

42 42 E4242MB3400FCU 58 Flush — —<br />

42 42 E4242MB3400SCU 58 Surface W4242MB3400CU 58<br />

Main Lug 400 Ampere<br />

120/240 Volts AC<br />

1Ø, 3-Wire<br />

65,000A IR<br />

Branch Circuits Indoor Enclosure – NEMA Type 1 Outdoor Enclosure – NEMA Type 3R<br />

Amp Rating No. of Spaces No. of Circuits Catalog Number<br />

Enclosure<br />

Height a Trim Style Catalog Number<br />

Enclosure<br />

Height a<br />

12 6 — — — W0606ML1400CU cd 43<br />

400<br />

30 30 E3030ML1400SCU 41 Surface W3030ML1400CU 43<br />

42 42 E4242ML1400FCU 47 Flush — —<br />

42 42 E4242ML1400SCU 47 Surface W4242ML1400CU 47<br />

240 Volts AC<br />

3Ø, 3-Wire, 4-Wire<br />

22,000A IR<br />

Branch Circuits Indoor Enclosure - NEMA Type 1 Outdoor Enclosure - NEMA Type 3R<br />

Amp Rating No. of Spaces No. of Circuits Catalog Number<br />

Enclosure<br />

Height a Trim Style Catalog Number<br />

Enclosure<br />

Height a<br />

30 30 E3030ML3400SCU 41 Surface — —<br />

400<br />

42 42 E4242ML3400FCU 47 Flush — —<br />

42 42 E4242ML3400SCU 47 Surface W4242ML3400CU 47<br />

a Indoor and outdoor enclosures are 20" wide by 6" deep.<br />

b UL listed as suitable for use as service equipment.<br />

c Accepts up to six QN style breakers<br />

d 22,000A IR<br />

1-16<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Generator Ready Load Centers<br />

Revised on 03/31/20<br />

1-Phase, 3-Wire SN, 120/240 Volts AC<br />

Generator Ready Load Centers<br />

The Siemens generator ready load center can save thousands<br />

of dollars in future generator installation expenses while<br />

keeping initial expenses to a minimum. Works with an<br />

automatic standby generator or a portable generator.<br />

Load center features:<br />

n UL Listed<br />

n Indoor Type 1 and outdoor Type 3R<br />

n 225A max rated<br />

n Flush or surface mounting<br />

n Fits between standard stud centers<br />

n Tin plated copper bus bars<br />

n 22 kAIC rated<br />

n 120/240V ~<br />

n Main lug – convertible to main breaker with addition of<br />

MBK150A, MBK200A, or MBK225A<br />

n Installation of transfer mechanism can be performed at time<br />

of generator installation<br />

NEMA 1<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Automatic transfer switch features:<br />

n UL Listed<br />

n Operates automatically when connected to generator<br />

n Transfers load from utility to generator and back to utility<br />

n Transfer switch (sold separately) catalog number:<br />

GENTFRSWTCH ac<br />

Indoor Enclosure – NEMA Type 1<br />

Amp<br />

Rating<br />

No. of<br />

Spaces b<br />

No. of<br />

Circuits b Catalog Number Main<br />

Enclosure<br />

Height d<br />

200 30 42 G3042B1200GEN Main Breaker 42<br />

225 30 42 G3042L1225GEN Main Lug 42<br />

200 42 54 G4254B1200GEN Main Breaker 44<br />

225 42 54 G4254L1225GEN Main Lug 44<br />

Outdoor Enclosure – NEMA Type 3R<br />

Amp<br />

Rating<br />

No. of<br />

Spaces b<br />

No. of<br />

Circuits b Catalog Number Main<br />

200 30 42 W3042B1200GEN Main Breaker 42<br />

225 30 42 W3042L1225GEN Main Lug 42<br />

Enclosure<br />

Height e<br />

GENTFRSWTCH<br />

a Q2125S provided with GENTFRSWTCH for use with<br />

automatic transfer mechanism.<br />

b 2 spaces and 2 circuits are reserved for standby<br />

generator installation.<br />

c Field install breaker for voltage sensing required.<br />

d Indoor enclosures are 14 1/4" wide by 3 7/8" deep.<br />

e Outdoor enclosures are 14 1/2" wide by 4 1/4" deep.<br />

NEMA 3R<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-17


Riser Panel Load Centers<br />

Revised on 03/31/20<br />

1-Phase, 3-Wire SN, 120/240 Volts AC<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Riser Panel Load Centers a<br />

Riser panel load centers are ideal for high rise applications.<br />

The shifted interior provides room for conductors to pass<br />

through the load center. The tap kits allow the installer to tap<br />

off from those conductors to power the panel.<br />

Features<br />

n UL Listed for use in 1Ø and 3Ø riser gutter applications.<br />

n Copper bus standard.<br />

n Main lug factory standard - convertible to main breaker.<br />

n Neutrals aligned on left side- keeps way clear for riser<br />

cables.<br />

n Available in 125 and 200 amp models.<br />

n Invertible for left and right hand applications.<br />

ECRLK250<br />

Riser Gutter Tap Kit b<br />

The riser gutter tap kit (ECRLK250) allows the installer to<br />

tap off the main conductors, eliminating the need to cut<br />

completely through the conductor. The tap kit accepts 250<br />

-1/0 on the main conductor side and 250-#6 on the tap side.<br />

R1632L1125CU<br />

Riser Gutter<br />

The riser gutter (RAG24) is used to convert any load center<br />

24” or larger into a riser panel.<br />

Features<br />

n Single and 3-phase applications<br />

n Compatible with any single or 3-phase Siemens load center<br />

24" or higher<br />

n Flush trim included<br />

n Load center mounting hardware and pass through brush<br />

included (Catalog no. RAG24)<br />

Any Load Center<br />

24" or larger<br />

RAG24<br />

1-phase, 3-wire SN, 120/240 Volts AC<br />

Catalog Number<br />

Dimensions (inches)<br />

Amp<br />

Rating<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits Aluminum Bus<br />

Aluminum Bus<br />

White Coating Copper Bus<br />

Copper Bus<br />

White Coating Height Width Depth<br />

Acceptable Main<br />

Breaker Kits<br />

125 16 32 R1632L1125 R1632L1125W R1632L1125CU — 24 14.25 3.88 MBK100A,MBK125A<br />

125 24 24 R2424L1125 R2424L1125W R2424L1125CU — 30 14.25 3.88 MBK100A, MBK125A<br />

125 24 42 R2442L1125 R2442L1125W R2442L1125CU R2442L1125CUW 30 14.25 3.88 MBK100A, MBK125A<br />

200 30 42 R3042L1200 R3042L1200W R3042L1200CU R3042L1200CUW 36 14.25 3.88 MBK150A, MBK200A<br />

a The riser panels are single phase only, but can be fed<br />

from 1-phase or 3-phase systems running through the<br />

gutter trough area.<br />

b ECRLK250 is sold separately.<br />

1-18<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


EQ ® Load Centers, Small Circuit and Circuit Breaker Enclosures<br />

1-Phase, 3-Wire SN, 120/240 Volts AC<br />

Revised on 03/31/20<br />

Features/Applications<br />

n Indoor and Outdoor Applications<br />

n UL Listed<br />

n 2 to 12 Space Options<br />

n SPA panels offer a 50A or 60A<br />

factory installed GFCI breaker<br />

n Service Entrance or Subfeed<br />

Applications<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Small Circuit Load<br />

Centers<br />

Ideal for subfeed<br />

applications<br />

Renovation Panel<br />

Ideal for older home renovation<br />

projects where the distance<br />

between the studs is narrower<br />

than current construction<br />

practices. The narrower panel<br />

eliminates the need to ‘notch’<br />

out the existing studs.<br />

Spa Panels<br />

Spa Panels are ideal for outdoor<br />

applications requiring the use<br />

of ground fault protection, such<br />

as hot tubs. A factory installed<br />

2-Pole GFCI breaker is provided,<br />

along with 2 extra circuits.<br />

Indoor Enclosure - NEMA Type 1<br />

Max Short<br />

Amp No. of No. of<br />

Circuit Bus<br />

Phase Lug<br />

Dimensions (inches)<br />

Rating Spaces Circuits Catalog Number Rating Material Mounting Wire Size<br />

Ground Bar H W D<br />

100<br />

10 20 E1020MB1100FCGP abc 22,000 Copper Flush<br />

14.6 12.3 3.7<br />

CU or AL<br />

ECGB10 Installed<br />

E1224ML1100FG de 100,000 Aluminum Flush 14.6 12.3 3.7<br />

12 24<br />

#4 - 2/0 AWG<br />

E1224ML1100FCU de 100,000 Copper Flush Use ECGB kits 14.6 12.3 3.7<br />

4 8<br />

E0408ML1125F fghij 100,000 Aluminum Flush j AL #12 - 2/0 AWG or<br />

12.8 6.5 3.3<br />

E0408ML1125S fghij 100,000 Aluminum Surface j CU #14 - 2/0 AWG<br />

Use ECGB or 12.8 6.5 3.3<br />

E0816ML1125F gi 100,000 Aluminum Flush<br />

ECLX kits<br />

14.6 12.3 3.7<br />

E0816ML1125S gi 100,000 Aluminum Surface 14.6 12.3 3.7<br />

125<br />

E0816ML1125FGB g ECGB10 or<br />

100,000 Aluminum Flush CU or AL<br />

14.6 12.3 3.7<br />

8 16<br />

ECLX071M Installed<br />

#4 - 2/0 AWG<br />

— 100,000 Aluminum Surface ECLX071M Installed 14.6 12.3 3.7<br />

E0816ML1125FCU g 100,000 Copper Flush<br />

14.6 12.3 3.7<br />

Use ECGB kits<br />

E0816ML1125SCU g 100,000 Copper Surface 14.6 12.3 3.7<br />

Outdoor Enclosure - NEMA Type 3R<br />

Max Short<br />

Amp No. of No. of<br />

Circuit Bus Hub<br />

Phase Lug<br />

Dimensions (inches)<br />

Rating Spaces Circuits Catalog Number Rating Material Provision Wire Size<br />

Ground Bar H W D<br />

100 2 4 W0204MB1100 cg 100,000 Aluminum 1.25” HS Hub<br />

Use ECGB or 12.1 6.2 4.4<br />

W0408ML1125 fhil 100,000 Aluminum<br />

AL #12 - 2/0 AWG or<br />

ECLX kits<br />

12.1 6.2 4.4<br />

4 8 W0408L1125SPA50 lm 100,000 Aluminum<br />

CU #14 - 2/0 AWG<br />

12.1 6.2 4.4<br />

ECGB5 Installed<br />

125<br />

W0408L1125SPA60 lm 100,000 Aluminum 12.1 6.2 4.4<br />

HS Cover<br />

8 16 W0816ML1125CU gi 100,000 Copper Plate<br />

Use ECGB or<br />

14.7 12.1 4.1<br />

ECLX kits<br />

150 4 4 W0404MB1150CTS cn 22,000 Copper<br />

20.0 11.1 4.7<br />

— 100,000 Aluminum CU or AL<br />

20.0 11.1 4.7<br />

8<br />

— 100,000 Aluminum #4 - 2/0 AWG<br />

20.0 11.1 4.7<br />

2” HS Hub ECLX384M Installed<br />

200 4<br />

W0404MB1200CT kn 22,000 Copper 20.0 11.1 4.7<br />

4<br />

W0404MB1200CTS kn HS Cover<br />

22,000 Copper<br />

Plate<br />

20.0 11.1 4.7<br />

a Suitable for use as service equipment when a main<br />

breaker (100A maximum) is used with retainer clip<br />

(Cat. No. ECMBR1).<br />

b Two Q115 and one Q130 included<br />

c 22KAIC Main Breaker factory installed<br />

d 70 amp maximum breaker.<br />

e Suitable for use as service entrace equipment when a<br />

main breaker (70A maximum) is used with reatiner clip<br />

(Cat. No. ECMBR1).<br />

f Will not accommodate a 2-pole circuit breaker with<br />

shunt trip.<br />

g Suitable for use as service equipment when not more<br />

than six main disconnecting means are provided.<br />

Check local codes and restrictions.<br />

h Packaged in quantities of 5.<br />

i CSA Listed<br />

j No Door<br />

k 10KAIC Main Breaker factory installed<br />

l l2-pole 60A GFCI, a restriction of #6 wire applies due<br />

to wire bend space of the enclosure.<br />

m Suffix SPA50 indicates a factory installed 50A 2-pole<br />

GFCI and suffix SPA60 indicates a factory installed<br />

60A 2-pole GFCI.<br />

n Suitable only for use as service equipment.<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-19


EQ ® Load Centers, Small Circuit and Circuit Breaker Enclosures<br />

1-Phase and 3-Phase, 240V AC Max.<br />

Revised on 03/31/20<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

1<br />

Features<br />

n Circuit breaker enclosures range from<br />

60A to 250A, indoor and outdoor models<br />

n UL listed<br />

n Suitable for use as service entrance<br />

equipment<br />

n UL listed for 60/75°C Conductors (See<br />

equipment markings for applications)<br />

n Outdoor type 3R devices use HS type<br />

hubs except for the W0204ML1060<br />

which uses HA type hubs<br />

W0202MB1200CU<br />

E0303ML3100CU<br />

Amp<br />

Rating<br />

No. of<br />

Poles<br />

Indoor Enclosure - NEMA Type 1<br />

Catalog Number<br />

Breaker<br />

Used a<br />

Max<br />

Short<br />

Circuit<br />

Rating<br />

1-Phase, 3-Wire SN - 120/240 Volts AC - Breaker Factory Installed<br />

Outdoor Enclosure - NEMA Type 3R<br />

Dimensions<br />

Max<br />

Dimensions<br />

(inches)<br />

Short (inches)<br />

Std.<br />

Breaker Circuit Std.<br />

Pkg. H W D Catalog Number Used a Rating Pkg. H W D<br />

100 2 E0202MB1100 Q2100 22,000 1 17.3 7.3 4.3 W0202MB1100CU Q2100 22,000 1 17.2 7.3 4.3<br />

150 2 — — — — — — — W0202MB1150CU QN2150H<br />

200 2 E0202MB1200 QN2200 22,000 1 20 8.7 4 W0202MB1200CU QN2200H<br />

65,000 1 19.8 8.7 5<br />

150 2 — — — — — — — WB2150BQR QR22B150L<br />

200 2 — — — — — — — WB2200BQR QR22B200L 10,000 1 26.9 7.1 4.4<br />

225 2 — — — — — — — WB2225BQR QR22B225L<br />

1-Phase, 3-Wire SN - 120/240 Volts AC - Enclosure Only<br />

E0204ML1060S<br />

60 2<br />

bd QP, QPH, or HQP 100,000 f 5 9.9 5.2 2.7 W0204ML1060bd QP, QPH, or HQP 100,000 f 5 8.1 5.5 3.5<br />

E0204ML1060F bd — —<br />

E0204ML1125SCU<br />

125 2<br />

c W0204ML1125CU<br />

QP or QPH 22,000 1 17.3 7.3 4.3<br />

c QP or QPH<br />

22,000 1 17.2 7.3 4.3<br />

E0204ML1125FCU c — —<br />

QN, QNH, or<br />

200 2 — — — — — — — W0202ML1200CU 65,000 1 19.8 8.7 5<br />

HQN<br />

1-4 — — — — — — — W0406ML1225CU QPP or QP 10,000 1 23.2 10.4 4.5<br />

225<br />

QR2, QRH2, or<br />

2 — — — — — — — QR2N3R2<br />

65,000 1 26.9 7.1 4.4<br />

HQR2<br />

QR2N1S<br />

QR2, QRH2,<br />

250 2<br />

HQR2, or HQR2H 100,000 1 31.4 9.6 5.6 — — — — — — —<br />

QR2N1F — — — — — — —<br />

3-Phase, 3-Wire 240 Volts AC or 3-Phase, 4-Wire SN — 120/208 Volts AC, 120/240, 240 Volts AC - Enclosure Only<br />

100 2-3<br />

250 2-3<br />

E0303ML3100S e QP or QPH<br />

W0303ML3100<br />

22,000 1 17.3 7.3 4.3<br />

e QP or QPH<br />

22,000 1 17.2 7.3 4.3<br />

EB3100S e BQ or BQH WB3100 e BQ or BQH<br />

QR2N1S<br />

QR2, QRH2,<br />

QR2, QRH2,<br />

QR2N3R3<br />

100,000 1 31.4 9.6 5.6<br />

HQR2, or 100,000 1 31.4 9.6 5.6<br />

HQR2, or HQR2H<br />

QR2N1F HQR2H<br />

— — — — — — —<br />

a Additional breaker types may be listed on the wiring<br />

diagram.<br />

b Will not accommodate 2-pole GFCI or Circuit breaker<br />

with shunt trip.<br />

c Can accommodate 2-pole GFCI breaker up to 60A.<br />

d CSA Listed<br />

e Will not accommodate circuit breaker with shunt trip.<br />

f Series rating<br />

1-20<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Renovation Interiors<br />

Revised on 03/31/20<br />

1 Phase, 3 WIRE, 120/240V<br />

Features<br />

n For use in home renovations<br />

with existing load centers a<br />

n Suitable for use in indoor<br />

Type 1 Enclosure<br />

n Interior, Flush Cover, and<br />

Hardware included<br />

n Adjustable depth<br />

n Incoming lugs: 2/0 - #4 AWG<br />

n UL listed<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Amp No. of No. of<br />

Min. Enclosure Size (inches) Max. Enclosure Size (inches) Cover Dimensions (inches)<br />

Rating Spaces Circuits Catalog Numbers L W D b L W D b L W<br />

100 8 16 RE0816ML1100J 13.00 10.50 3.75 19.00 14.25 6.00 22.00 18.00<br />

100 8 16 RE0816ML1100K 20.00 10.50 3.75 26.00 14.25 6.00 29.00 18.00<br />

125 12 24 RE1224ML1125J 17.00 12.25 3.75 21.00 14.25 6.00 23.00 18.00<br />

125 12 24 RE1224ML1125K 22.00 12.25 3.75 26.00 14.25 6.00 29.00 18.00<br />

a Existing enclosure must mearsure within listed<br />

dimensions for the use of the kit.<br />

b Depth of enclosure is measured from finished wall<br />

surface.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-21


Load Center Accessories <br />

Revised on 03/31/20<br />

Ground bar kits, hubs, lugs, and conversion kits<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Catalog<br />

Number<br />

Description<br />

Pack<br />

Qty<br />

Ground Bar Kits<br />

EC1GB8 GROUND BAR KIT-8 POS 1<br />

EC1GB82 GROUND BAR KIT-8 POS, 2/0 LUG 1<br />

EC2GB12 GROUND BAR KIT-12 POS 1<br />

EC2GB122 GROUND BAR KIT-12 POS, 2/0 LUG 1<br />

EC2GB15 GROUND BAR KIT-15 POS 1<br />

EC2GB152 GROUND BAR KIT-15 POS, 2/0 LUG 1<br />

EC3GB21 GROUND BAR KIT-21 POS 1<br />

EC3GB212 GROUND BAR KIT-21 POS, 2/0 LUG 1<br />

EC3GB27 GROUND BAR KIT-27 POS 1<br />

EC3GB272 GROUND BAR KIT-27 POS, 2/0 LUG 1<br />

EC3GB30 GROUND BAR KIT-30 POS 1<br />

EC3GB302 GROUND BAR KIT-30 POS, 2/0 LUG 1<br />

EC3GB352 GROUND BAR KIT-35 POS, 2/0 LUG 1<br />

EC3GB352G GROUND BAR KIT-35 POS, 2/0 LUG b 1<br />

Ground Bar Kits (For Legacy Load Centers)<br />

ECGB5 GROUND BAR KIT-5 POS 1<br />

ECGB10 GROUND BAR KIT-10 POS 1<br />

ECGB101 GROUND BAR KIT-10 POS, 1/0 LUG 1<br />

ECGB14 GROUND BAR KIT-14 POS 1<br />

ECGB141 GROUND BAR KIT-14 POS, 1/0 LUG 1<br />

ECGB142 GROUND BAR KIT-14 POS, 2/0 LUG 1<br />

ECGB20 GROUND BAR KIT-20 POS 1<br />

ECGB201 GROUND BAR KIT-20 POS, 1/0 LUG 1<br />

ECGB202 GROUND BAR KIT-20 POS, 2/0 LUG 1<br />

ECINSGB5 INSULATED GROUND BAR KIT-5 POS 1<br />

ECINSGB14 INSULATED GROUND BAR KIT-14 POS 1<br />

ECINSGB20 INSULATED GROUND BAR KIT-20 POS 1<br />

Hubs<br />

ECHA000<br />

CLOSURE PLATE 1<br />

ECHA075 HUB - 3/4” 1<br />

ECHA100<br />

HA Type<br />

W0204ML1060<br />

HUB - 1” 1<br />

ECHA125 HUB - 1 1/4” 1<br />

ECHA150 HUB - 1 1/2” 1<br />

ECHS000<br />

CLOSURE PLATE 1<br />

ECHS075 HUB - 3/4” 1<br />

ECHS100 HS Type HUB - 1” 1<br />

ECHS125<br />

PL & ES and<br />

Small Circuit<br />

HUB - 1 1/4” 1<br />

ECHS150 Loadcenters HUB - 1 1/2” 1<br />

ECHS200 HUB - 2” 1<br />

ECHS250 HUB - 2 1/2” 1<br />

ECHV000<br />

CLOSURE PLATE 1<br />

ECHV200 HUB - 2” 1<br />

ECHV250 HV Type HUB - 2.5” 1<br />

300-400A<br />

ECHV300 Loadcenters HUB 3” 1<br />

ECHV350 HUB - 3.5” 1<br />

ECHV400 HUB - 4” 1<br />

Lock Kits<br />

ECQFL2<br />

ECQFL1<br />

ECQFL3<br />

FLUSH LOCK KIT FOR ULT., PL, ES, 3PH<br />

100A-225A<br />

FLUSH LOCK KIT-REPLACEMENT FOR<br />

EQ LC<br />

ADD-A-LOCK (FLUSH LOCK )<br />

FOR 300-400A LC<br />

1<br />

1<br />

1<br />

Catalog<br />

Number<br />

Description<br />

Pack<br />

Qty<br />

Load Center Conversion Kits cd<br />

MBK100A MAIN BREAKER KIT 100A 1PH 22K 1<br />

MBK125A MAIN BREAKER KIT 125A 1PH 22K 1<br />

MBK150A MAIN BREAKER KIT 150A 1PH 22K 1<br />

MBK200A MAIN BREAKER KIT 200A 1PH 22K 1<br />

MBK225A MAIN BREAKER KIT 225A 1PH 22K 1<br />

MBK3100 MAIN BREAKER KIT 100A 3PH QP 240V 10K 1<br />

MBK3125R MAIN BREAKER KIT 125A 3PH 240V 10K, QR 1<br />

MBK3150R MAIN BREAKER KIT 150A 3PH 240V 10K, QR 1<br />

MBK3175R MAIN BREAKER KIT 175A 3PH 240V 10K, QR 1<br />

MBK3200R MAIN BREAKER KIT 200A 3PH 240V 10K, QR 1<br />

MBK3225R MAIN BREAKER KIT 225A 3PH 240V 10K, QR 1<br />

MBK3125HR MAIN BREAKER KIT 125A 3PH 240V 22K, QR 1<br />

MBK3150HR MAIN BREAKER KIT 150A 3PH 240V 22K, QR 1<br />

MBK3175HR MAIN BREAKER KIT 175A 3PH 240V 22K, QR 1<br />

MBK3200HR MAIN BREAKER KIT 200A 3PH 240V 22K, QR 1<br />

MBK3225HR MAIN BREAKER KIT 225A 3PH 240V 22K, QR 1<br />

MBK3125HHR MAIN BREAKER KIT 125A 3PH 240V 65K, QR 1<br />

MBK3150HHR MAIN BREAKER KIT 150A 3PH 240V 65K, QR 1<br />

MBK3175HHR MAIN BREAKER KIT 175A 3PH 240V 65K, QR 1<br />

MBK3200HHR MAIN BREAKER KIT 200A 3PH 240V 65K, QR 1<br />

MBK3225HHR MAIN BREAKER KIT 225A 3PH 240V 65K, QR 1<br />

HMBK3125HR MAIN BREAKER KIT 125A 3PH 240V 100K, QR 1<br />

HMBK3150HR MAIN BREAKER KIT 150A 3PH 240V 100K, QR 1<br />

HMBK3175HR MAIN BREAKER KIT 175A 3PH 240V 100K, QR 1<br />

HMBK3200HR MAIN BREAKER KIT 200A 3PH 240V 100K, QR 1<br />

HMBK3225HR MAIN BREAKER KIT 225A 3PH 240V 100K, QR 1<br />

ECMLK125 1 PH MAIN LUG CONVERSION KIT 100-125A 1<br />

ECMLK225 1 PH MAIN LUG CONVERSION KIT 150-225A 1<br />

ECMLK3125 3 PH MAIN LUG CONVERSION KIT 100-125A 1<br />

ECMLK3225 3 PH MAIN LUG CONVERSION KIT 150-225A 1<br />

Lug Kits<br />

ECCS1 COLLAR STRAP FOR GRD BARS #14-1/0 1<br />

ECCS2 COLLAR STRAP FOR GRD BARS #6-250 1<br />

ECLKB1 NEUTRAL LUG KIT WITH BOND TAB 1<br />

ECLK3 NEUTRAL LUG KIT #1-300 1<br />

ECLK1-2 NEUTRAL LUG KIT #2 TO 1/0 1<br />

ECLK2N NEUTRAL LUG KIT #4-2/0 1<br />

ECLK3N NEUTRAL LUG KIT #1-300 1<br />

ECLK2 NEUTRAL LUG KIT #4-2/0 1<br />

ECLK2SC 2/0 LUG FOR 125AMP NEUTRAL FEEDER 1<br />

ECLK2125 125A SUB FEED LUGS-USES 2 SPACES 1<br />

ECLK2225 150A-225A SUB FEED LUGS-USES 4 SPACES 1<br />

ECLK3225 3P SUB FEED LUGS-USES 6 SPACES 1<br />

ECRLK250 RISER LUG KIT 250 KCMIL 3<br />

Miscellaneous Load Center Accessories<br />

ECCP1 PKG OF 100 CIRCUIT DIRECTORY 100<br />

ECQF3 QP/BQ/ED2 FILLER PLATE 5<br />

ECMBF125 1 PH 100&125A MAIN BREAKER FILLER PLATE 1<br />

EC3PMFP1 3 POLE MAIN FILLER PLATE, QJ 1<br />

EC3PMFPR 3 POLE MAIN FILLER PLATE, QR 1<br />

ECSMK1 SURFACE MOUNT 1/4" SPACE KIT FOR LC'S 4<br />

ECTS2 LC TRIM SCREWS 6<br />

ECTS2W LC TRIM SCREWS WHITE 6<br />

ECLCHINGE GREY LC HINGES 100<br />

ECADHLCDIRLBL ADHESIVE LC DIRECTORY LABELS 100<br />

ECSIELATCH SIEMENS LC LATCHES 25<br />

ECBONDSCRW LC BOND SCREW 10<br />

ECSN1 SCREWS & NUTS FOR HC HUB-BOTTOM USE 4<br />

RAG24 RISER AUX GUTTER 24" 1<br />

ECAFL ARC FLASH LABEL 10<br />

a The pack quantity is the number that is sold in a pack. Items listed on this page<br />

must be ordered in multiples of pack quantities but items are priced per each.<br />

For example, ECRLK250 come 3 to a pack so must be ordered in multiples of 3<br />

but pricing would be individual unit price times 3.<br />

b Bar has green-colored screws.<br />

c QR Main Breaker Kits include a QR filler plate.<br />

d Main Breaker Kits include line terminal barriers.<br />

1-22<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Load Centers Accessories<br />

Revised on 03/31/20<br />

Miscellaneous Load Center Accessories<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Lug Kit, 3-Pole, Subfeed or<br />

Feed thru Applications<br />

ECLK3225<br />

2 PH Main Lug Conversion Kit<br />

150A-225A<br />

ECMLK225<br />

Main Breaker Kit<br />

200A - 225A, 1PH 22K<br />

MBK200A<br />

3-Pole Main Breaker Kit<br />

MBK3200<br />

Main Breaker Retainer Kit for EQ<br />

Load Centers<br />

ECMBR1<br />

Main Breaker Retainer kit for PN, SN, PL, ES, &<br />

Ultimate Load Centers<br />

ECMBR2<br />

Ground Bar Kit<br />

20 POS. 2/0 Lug<br />

ECGB202<br />

Ground Bar Kit, ECGB14<br />

Neutral Lug Kit, ECLK1-2<br />

wire range — #2-1 AWG<br />

Cu or Al<br />

Neutral Lug Kit, ECLK3<br />

wire range — #1-300 MCM<br />

Neutral Lug Kit, ECLK2<br />

wire range — #4-#2/0 AWG<br />

Cu or Al<br />

For use on Ground Bar only<br />

Collar Strap, Wire Range;<br />

ECCS1; ECCS2<br />

Add-A-Lock<br />

(Flush Lock) ECQFL1<br />

For EQ load centers<br />

Filler Plate, ECQF3<br />

Add-A-Lock<br />

(Flush Locak), ECQFL2<br />

PN, SN, PL, ES, Ultimate Load<br />

Centers and EQ III up to 225A<br />

Add-A-Lock<br />

(Flush Lock), ECQFL3<br />

300-400A Load Centers<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-23


Load Centers Accessories<br />

Revised on 03/31/20<br />

Load Center and Meter Combos Accessories<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Load centers and meter combos<br />

Touchsafe barriers are required for any single main service<br />

entrance application for a panel covered under UL 67. Line<br />

Terminal Barriers will be included in Main Breaker Load<br />

Centers and Single Main Meter Combos manufactured after<br />

January 1, <strong>2017</strong>.<br />

Single phase and 3-phase main breaker kits will include a<br />

barrier. Field installable kits are being created for replacements<br />

if needed and line terminal barriers are being added to hold<br />

down kits that can be used in back-fed applications. The<br />

barriers are designed to have minimal interference during<br />

load center installation, and can be removed and reattached<br />

as necessary.<br />

Catalog number<br />

Description<br />

ECLTB1<br />

For EQ Main Breakers/MBK kits 100A-125A<br />

ECLTB2<br />

For EQ Main Breakers/MBK kits 150A-225A<br />

ECLTB3<br />

For QN / QNR type breakers<br />

ECLTB4<br />

For QR 3 phase breakers<br />

ECMBR1 a<br />

For 2 Pole QP / MP-T type breakers for EQIII (extruded basepan)<br />

and Line 5<br />

ECMBR2 a<br />

For 2 Pole QP / MP-T type breakers to be used with PN, SN, ES, PL,<br />

Ultimate, and legacy Murray or Rock Solid load centers<br />

ECMBR3<br />

For 3 Pole QP / MP-T type breakers to be used with PL,<br />

ES 3 phase load centers<br />

ECLX387HD<br />

For 2 Pole MP-T type breakers in legacy Murray load centers<br />

a Barrier fits with 2-pole QP 70A and above and all<br />

amperages of QPH and HQP.<br />

1-24<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Load Centers Accessories<br />

Revised on 03/31/20<br />

Manual Transfer Interlock Kits for Load Centers and Meter Combinations<br />

Prevents dangerous feedback between two sources of power<br />

Manual Transfer Interlock Kits a<br />

Catalog<br />

number<br />

ECSBPK01<br />

Usage<br />

Information<br />

For use on load centers or meter combinations<br />

that will accept 2-pole circuit breakers opposite<br />

one another as shown.<br />

Utility main<br />

breaker types<br />

Standby main<br />

breaker types<br />

QP, QPH, HQPH QP, QPH, HQPH 1<br />

Interlock<br />

Number<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

ECSBPK02<br />

For use on load centers or meter combinations<br />

that will accept 2- or 4-pole next to a 2-pole<br />

circuit breaker side by side as shown.<br />

QP, QPH, HQPH QP, QPH, HQPH 2<br />

ECSBPK03<br />

For use on Ultimate and Rock Solid<br />

load centers, 150 amp and higher,<br />

to connect the main breaker<br />

to a 2-pole circuit breaker.<br />

MBK150A,<br />

MBK200A, OR<br />

MBK225A<br />

QP, QPH, HQPH 3<br />

ECSBPK10<br />

For use on PN and SN plug-on neutral load<br />

centers, 150 amp and higher, to connect the<br />

main breaker to a 2-pole circuit breaker.<br />

ECSBPK04<br />

For use on Ultimate and Rock Solid<br />

load centers, 125 amp and lower,<br />

to connect the main breaker to a<br />

2-pole circuit breaker.<br />

MBK100A or<br />

MBK125A<br />

QP, QPH, HQPH 4<br />

ECSBPK11<br />

For use on PN and SN plug-on neutral load<br />

centers, 125 amp and lower, to connect the<br />

main breaker to a 2-pole circuit breaker.<br />

ECSBPK05<br />

For use on load centers or meter combinations<br />

that will accept a QNR (MD-TR) frame circuit<br />

breaker next to a 2-pole circuit breaker as<br />

shown.<br />

QNR, QNRH, HQNR QP, QPH, HQPH 5<br />

ECSBPK06<br />

For use on load centers or meter combinations<br />

that will accept a QN (MD-T) frame circuit<br />

breaker next to a 2-pole circuit breaker as<br />

shown.<br />

QN, QNH, HQN QP, QPH, HQPH 6<br />

ECSBPK07<br />

For use on load centers or meter<br />

combinations that will accept two QNR<br />

(MD-TR) circuit breakers side by side as<br />

shown OR will accept two QN (MD--T) circuit<br />

breakers side by side as shown.<br />

QNR, QNRH, HQNR,<br />

QN, QNH, HQN<br />

QNR, QNRH,<br />

HQNR QN,<br />

QNH, HQN<br />

7<br />

a Manual breaker interlock kits are attached to the<br />

breakers not the trim of the load center.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-25


Load Centers<br />

Revised on 03/31/20<br />

1-Phase Indoor and 1-Phase & 3-Phase Outdoor Enclosures—Knockout Diagrams<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

1<br />

SN and PN<br />

1 Phase Load Centers<br />

Indoor<br />

1-26<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Load Centers<br />

3-Phase Indoor and Riser Enclosures—Knockout Diagrams<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

New Riser Panel KO Diagram<br />

6/17/08<br />

(10) K.O.s for<br />

1/2", 3/4", 1" Conduit<br />

(8) K.O.s for<br />

1/2", 3/4" Conduit<br />

(42) K.O.s for 1/2" Conduit<br />

(2) K.O.s for<br />

1-1/2", 2", 2-1/2" Conduit<br />

(4) 5/16" K.O.s<br />

RAG24 KO Dwg<br />

1/5/11<br />

(4) K.O.s for<br />

1-1/2", 2", 2-1/2"<br />

Conduit<br />

(8) K.O.s for<br />

1", 1-1/4", 1-1/2", 2", 2-1/2"<br />

Conduit<br />

(4) Mounting Holes<br />

All Riser Panels<br />

RAG24<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-27


Load Centers<br />

Outdoor Enclosures—Knockout Diagrams<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

2 Type "HV"<br />

Hub Openings<br />

4 Mounting Holes<br />

.218 Dia<br />

12 K.O.'s For<br />

.5", .75", Conduit<br />

4 K.O.'s For<br />

.5", .75", 1",<br />

1.25" Conduit<br />

5 K.O.'s For<br />

1", 1.25", 1.50",<br />

2", 2.50" Conduit<br />

2 K.O.'s For<br />

.75", 1", 1.25", 1.50" Conduit<br />

2 K.O.'s For<br />

2.50", 3", 3.50" Conduit<br />

Outdoor 400A<br />

Load Center<br />

W0406ML1125CU<br />

W0204ML1060<br />

W0408ML1125<br />

1-28<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Load Centers<br />

Outdoor Enclosures—Knockout Diagrams<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

WB2225 and WB32225<br />

W0204ML1125<br />

W0303ML3100<br />

WB3100<br />

W0612ML1125<br />

W0816ML1125<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-29


Load Centers<br />

Indoor Enclosures—Knockout Diagrams<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

1<br />

24 K.O.'s For<br />

.5", .75"<br />

Conduit<br />

Indoor 300-400A<br />

Load Center<br />

8 K.O.'s For<br />

.5", .75", 1",<br />

1.25" Conduit<br />

E0612ML1125<br />

E0816ML1125<br />

E0816ML1125<br />

E1224ML1100F<br />

E1224ML1100F<br />

E0408ML1125<br />

E0408ML1125<br />

E0303ML3100SCU<br />

E0303ML3100SCU<br />

EB3100<br />

EB3100<br />

E0204ML1060<br />

E0204ML1060<br />

1-30<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Load Centers<br />

Cross Reference<br />

Phase Enclosure Legacy Catalog Number New Catalog Number Main Amperage Bus<br />

1 Indoor LC1224B1100 SN1224B1100 Main Breaker 100 Aluminum<br />

1 Indoor LC1224L1125 SN1224L1125 Main Lug 125 Aluminum<br />

1 Indoor LC1224L1125P SN2020B1100P1 Main Lug 125 Aluminum<br />

1 Indoor LC1224L1125W SN1224L1125W Main Lug 125 Aluminum<br />

1 Indoor LC1632B1150 SN1632B1150 Main Breaker 150 Aluminum<br />

1 Indoor LC1632B1200 SN1632B1200 Main Breaker 200 Aluminum<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

1 Indoor LC1632L1125 SN1632L1125 Main Lug 125 Aluminum<br />

1 Indoor LC1632L1125W SN1632L1125W Main Lug 125 Aluminum<br />

1 Indoor LC1632L1150 SN1632L1150 Main Lug 150 Aluminum<br />

1 Indoor LC2040B1100 SN2040B1100 Main Breaker 100 Aluminum<br />

1 Indoor LC2040B1100CU PN2040B1100C Main Breaker 100 Copper<br />

1 Indoor LC2040B1100P SN2020B1100P1 Main Breaker 100 Aluminum<br />

1 Indoor LC2040B1150 SN2040B1150 Main Breaker 150 Aluminum<br />

1 Indoor LC2040B1200 SN2040B1200 Main Breaker 200 Aluminum<br />

1 Indoor LC2040B1200CU PN2040B1200C Main Breaker 200 Copper<br />

1 Indoor LC2040B1200P SN3048B1200P1 Main Breaker 200 Aluminum<br />

1 Indoor LC2040L1125 SN2040L1125 Main Lug 125 Aluminum<br />

1 Indoor LC2040L1125CU PN2040L1125C Main Lug 125 Copper<br />

1 Indoor LC2040L1200 SN2040L1200 Main Lug 200 Aluminum<br />

1 Indoor LC2040L1200CU PN2040L1200C Main Lug 200 Copper<br />

1 Indoor LC2440B1100 SN2448B1100 Main Breaker 100 Aluminum<br />

1 Indoor LC2440B1150 SN2448B1150 Main Breaker 150 Aluminum<br />

1 Indoor LC2440B1200 SN2448B1200 Main Breaker 200 Aluminum<br />

1 Indoor LC2440L1150 SN2448L1150 Main Lug 150 Aluminum<br />

1 Indoor LC2440L1200 SN2448L1200 Main Lug 200 Aluminum<br />

1 Indoor LC2448B1100 SN2448B1100 Main Breaker 100 Aluminum<br />

1 Indoor LC2448B1100P SN2020B1100P1 Main Breaker 100 Aluminum<br />

1 Indoor LC3040B1100 SN3048B1100 Main Breaker 100 Aluminum<br />

1 Indoor LC3040B1100W SN3048B1100W Main Breaker 100 Aluminum<br />

1 Indoor LC3040B1150 SN3048B1150 Main Breaker 150 Aluminum<br />

1 Indoor LC3040B1200 SN3048B1200 Main Breaker 200 Aluminum<br />

1 Indoor LC3040B1200CU PN3048B1200C Main Breaker 200 Copper<br />

1 Indoor LC3040B1200P SN3048B1200P1 Main Breaker 200 Aluminum<br />

1 Indoor LC3040L1125 SN3048L1125 Main Lug 125 Aluminum<br />

1 Indoor LC3040L1200 SN3048L1200 Main Lug 200 Aluminum<br />

1 Indoor LC3040L1200CU PN3048L1200C Main Lug 200 Copper<br />

1 Indoor LC3054B1200 SN3048B1200 Main Breaker 200 Aluminum<br />

1 Indoor LC3060B1200P SN3048B1200P1 Main Breaker 200 Aluminum<br />

1 Indoor LC4040B1200 SN4040B1200 Main Breaker 200 Aluminum<br />

1 Indoor LC4040B1200CU PN4040B1200C Main Breaker 200 Copper<br />

1 Indoor LC4040B1200P SN4040B1200P1 Main Breaker 200 Aluminum<br />

1 Indoor LC4040L1200 SN4040L1200 Main Lug 200 Aluminum<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-31


Load Centers<br />

Cross Reference<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Phase Enclosure Legacy Catalog Number New Catalog Number Main Amperage Bus<br />

1 Indoor LC4040L1200CU PN4040L1200C Main Lug 200 Copper<br />

1 Indoor LC4040L1200W SN4040L1200W Main Lug 200 Aluminum<br />

1 Indoor LC4060B1200 SN4060B1200 Main Breaker 200 Aluminum<br />

1 Indoor LC4060L1225 SN4060L1225 Main Lug 225 Aluminum<br />

1 Indoor LC4242L1225CU PN4264L1225C Main Lug 225 Copper<br />

1 Indoor LC4260B1200 SN4264B1200 Main Breaker 200 Aluminum<br />

1 Indoor LC4260B1200P SN4040B1200P1 Main Breaker 200 Aluminum<br />

1 Outdoor LW0816L1200TR SNW0816L1200T Main Lug 200 Aluminum<br />

1 Outdoor LW1224B1100 SNW1224B1100 Main Breaker 100 Aluminum<br />

1 Outdoor LW1224B1200 SNW1224B1200 Main Breaker 200 Aluminum<br />

1 Outdoor LW1224L1125 SNW1224L1125 Main Lug 125 Aluminum<br />

1 Outdoor LW1224L1200 SNW1224L1200 Main Lug 200 Aluminum<br />

1 Outdoor LW1224L1225CU PNW1224L1225C Main Lug 225 Copper<br />

1 Outdoor LW1632B1100 SNW1632B1100 Main Breaker 100 Aluminum<br />

1 Outdoor LW1632L1125 SNW1632L1125 Main Lug 125 Aluminum<br />

1 Outdoor LW2040B1150 SNW2040B1150 Main Breaker 150 Aluminum<br />

1 Outdoor LW2040B1200 SNW2040B1200 Main Breaker 200 Aluminum<br />

1 Outdoor LW2040L1125 SNW2040L1125 Main Lug 125 Aluminum<br />

1 Outdoor LW2040L1200 SNW2040L1200 Main Lug 200 Aluminum<br />

1 Outdoor LW3040B1200 SNW3048B1200 Main Breaker 200 Aluminum<br />

1 Outdoor LW3040L1200 SNW3048L1200 Main Lug 200 Aluminum<br />

1 Outdoor LW4040B1200 SNW4040B1200 Main Breaker 200 Aluminum<br />

1 Outdoor LW4242L1225CU PNW4264L1225C Main Lug 225 Copper<br />

1 Indoor P1212L1125CU PN1212L1125C Main Lug 125 Copper<br />

1 Indoor P1224B1100CU PN1224B1100C Main Breaker 100 Copper<br />

1 Indoor P1224L1125CU PN1224L1125C Main Lug 125 Copper<br />

1 Indoor P1224L1125CUSG PN1224L1125C Main Lug 125 Copper<br />

1 Indoor P1224L1200CU PN1224L1200C Main Lug 200 Copper<br />

1 Indoor P1624B1100CU PN1632B1100C Main Breaker 100 Copper<br />

1 Indoor P1624B1100CUW PN1632B1100CW Main Breaker 100 Copper<br />

1 Indoor P1624L1125CU PN1632L1125C Main Lug 125 Copper<br />

1 Indoor P1624L1125CUSG PN1632L1125C Main Lug 125 Copper<br />

1 Indoor P2020B1100CU PN2020B1100C Main Breaker 100 Copper<br />

1 Indoor P2020L1125CU PN2020L1125C Main Lug 125 Copper<br />

1 Indoor P2020L1125CUW PN2020L1125CW Main Lug 125 Copper<br />

1 Indoor P2024B1100CU PN2040B1100C Main Breaker 100 Copper<br />

1 Indoor P2024L1125CU PN2040L1125C Main Lug 125 Copper<br />

1 Indoor P2030B1150CU PN2040B1150C Main Breaker 150 Copper<br />

1 Indoor P2030L1125CUSG PN2040L1125C Main Lug 125 Copper<br />

1 Indoor P2030L1150CU PN2040L1150C Main Lug 150 Copper<br />

1 Indoor P2030L1150CUSG PN2040L1150C Main Lug 150 Copper<br />

1 Indoor P2040B1100ACU PN2040B1100C Main Breaker 100 Copper<br />

1-32<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Load Centers<br />

Cross Reference<br />

Phase Enclosure Legacy Catalog Number New Catalog Number Main Amperage Bus<br />

1 Indoor P2040B1100ACUW PN2040B1100CW Main Breaker 100 Copper<br />

1 Indoor P2040B1150ACU PN2040B1150C Main Breaker 150 Copper<br />

1 Indoor P2040B1150ACUW PN2040B1150CW Main Breaker 150 Copper<br />

1 Indoor P2040B1200ACU PN2040B1200C Main Breaker 200 Copper<br />

1 Indoor P2040B1200ACUW PN2040B1200CW Main Breaker 200 Copper<br />

1 Indoor P2040B1200CU PN2040B1200C Main Breaker 200 Copper<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

1 Indoor P2040L1125ACU PN2040L1125C Main Lug 125 Copper<br />

1 Indoor P2040L1125ACUW PN2040L1125CW Main Lug 125 Copper<br />

1 Indoor P2040L1150ACU PN2040L1150C Main Lug 150 Copper<br />

1 Indoor P2040L1150ACUW PN2040L1150CW Main Lug 150 Copper<br />

1 Indoor P2040L1200ACU PN2040L1200C Main Lug 200 Copper<br />

1 Indoor P2040L1200ACUW PN2040L1200CW Main Lug 200 Copper<br />

1 Indoor P2040L1200CU PN2040L1200C Main Lug 200 Copper<br />

1 Indoor P2424B1100CU PN2424B1100C Main Breaker 100 Copper<br />

1 Indoor P2430L1125CUSG PN2448L1125C Main Lug 125 Copper<br />

1 Indoor P2440L1125CU PN2448L1125C Main Lug 125 Copper<br />

1 Indoor P2440L1125CUW PN2448L1125CW Main Lug 125 Copper<br />

1 Indoor P2440L1200CU PN2448L1200C Main Lug 200 Copper<br />

1 Indoor P2448B1100ACU PN2424B1100C Main Breaker 100 Copper<br />

1 Indoor P2448B1100ACUW PN2424B1100CW Main Breaker 100 Copper<br />

1 Indoor P2448L1125ACU PN2448L1125C Main Lug 125 Copper<br />

1 Indoor P2448L1125ACUW PN2448L1125CW Main Lug 125 Copper<br />

1 Indoor P2448L1200ACU PN2448L1200C Main Lug 200 Copper<br />

1 Indoor P2448L1200ACUW PN2448L1200CW Main Lug 200 Copper<br />

1 Indoor P3030B1100CU PN3030B1100C Main Breaker 100 Copper<br />

1 Indoor P3030B1125CU PN3030B1125C Main Breaker 125 Copper<br />

1 Indoor P3030B1125CUW PN3030B1125CW Main Breaker 125 Copper<br />

1 Indoor P3030B1150CU PN3030B1150C Main Breaker 150 Copper<br />

1 Indoor P3030L1200CU PN3030L1200C Main Lug 200 Copper<br />

1 Indoor P3040B1200 PN3048B1200 Main Breaker 200 Aluminum<br />

1 Indoor P3040B1200CU PN3048B1200C Main Breaker 200 Copper<br />

1 Indoor P3040B1200W PN3048B1200W Main Breaker 200 Aluminum<br />

1 Indoor P3040L1125CU PN3048L1125C Main Lug 125 Copper<br />

1 Indoor P3040L1125CUW PN3048L1125CW Main Lug 125 Copper<br />

1 Indoor P3040L1200 PN3048L1200 Main Lug 200 Aluminum<br />

1 Indoor P3040L1200CU PN3048L1200C Main Lug 200 Copper<br />

1 Indoor P3040L1200CUSG PN3048L1200C Main Lug 200 Copper<br />

1 Indoor P3040L1200CUW PN3048L1200CW Main Lug 200 Copper<br />

1 Indoor P3040L1200SG PN3048L1200 Main Lug 200 Aluminum<br />

1 Indoor P3040L1200W PN3048L1200W Main Lug 200 Aluminum<br />

1 Indoor P3042B1125CUSP PN3030B1125C Main Breaker 125 Copper<br />

1 Indoor P3054B1200S140 PN3048B1200S14 Main Breaker 200 Copper<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-33


Load Centers<br />

Cross Reference<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Phase Enclosure Legacy Catalog Number New Catalog Number Main Amperage Bus<br />

1 Indoor P3054L1200CU PN3048L1200C Main Lug 200 Copper<br />

1 Indoor P3060B1100ACU PN3030B1100C Main Breaker 100 Copper<br />

1 Indoor P3060B1100ACUW PN3030B1100CW Main Breaker 100 Copper<br />

1 Indoor P3060B1125ACU PN3030B1125C Main Breaker 125 Copper<br />

1 Indoor P3060B1125ACUW PN3030B1125CW Main Breaker 125 Copper<br />

1 Indoor P3060B1150ACU PN3030B1150C Main Breaker 150 Copper<br />

1 Indoor P3060B1150ACUW PN3030B1150CW Main Breaker 150 Copper<br />

1 Indoor P3060B1200A PN3048B1200 Main Breaker 200 Aluminum<br />

1 Indoor P3060B1200ACU PN3048B1200C Main Breaker 200 Copper<br />

1 Indoor P3060B1200ACUW PN3048B1200CW Main Breaker 200 Copper<br />

1 Indoor P3060B1200AW PN3048B1200W Main Breaker 200 Aluminum<br />

1 Indoor P3060L1125ACU PN3048L1125C Main Lug 125 Copper<br />

1 Indoor P3060L1125ACUW PN3048L1125CW Main Lug 125 Copper<br />

1 Indoor P3060L1200A PN3048L1200 Main Lug 200 Aluminum<br />

1 Indoor P3060L1200ACU PN3048L1200C Main Lug 200 Copper<br />

1 Indoor P3060L1200ACUW PN3048L1200CW Main Lug 200 Copper<br />

1 Indoor P3060L1200AW PN3048L1200W Main Lug 200 Aluminum<br />

1 Indoor P4040B1200 PN4040B1200 Main Breaker 200 Aluminum<br />

1 Indoor P4040B1200CU PN4040B1200C Main Breaker 200 Copper<br />

1 Indoor P4040B1200CUSG PN4040B1200C Main Breaker 200 Copper<br />

1 Indoor P4040B1200CUW PN4040B1200CW Main Breaker 200 Copper<br />

1 Indoor P4040B1200W PN4040B1200W Main Breaker 200 Aluminum<br />

1 Indoor P4040L1125CU PN4040L1125C Main Lug 125 Copper<br />

1 Indoor P4040L1125CUW PN4040L1125CW Main Lug 125 Copper<br />

1 Indoor P4040L1200 PN4040L1200 Main Lug 200 Aluminum<br />

1 Indoor P4040L1200CU PN4040L1200C Main Lug 200 Copper<br />

1 Indoor P4040L1200CUSG PN4040L1200C Main Lug 200 Copper<br />

1 Indoor P4040L1200CUW PN4040L1200CW Main Lug 200 Copper<br />

1 Indoor P4040L1200SG PN4040L1200 Main Lug 200 Aluminum<br />

1 Indoor P4060B1200S140 PN4060B1200S14 Main Breaker 200 Copper<br />

1 Indoor P4080B1200A PN4060B1200 Main Breaker 200 Aluminum<br />

1 Indoor P4080B1200ACU PN4060B1200C Main Breaker 200 Copper<br />

1 Indoor P4080B1200ACUW PN4060B1200CW Main Breaker 200 Copper<br />

1 Indoor P4080B1200AW PN4060B1200W Main Breaker 200 Aluminum<br />

1 Indoor P4080L1125ACU PN4040L1125C Main Lug 125 Copper<br />

1 Indoor P4080L1125ACUW PN4040L1125CW Main Lug 125 Copper<br />

1 Indoor P4080L1200A PN4040L1200 Main Lug 200 Aluminum<br />

1 Indoor P4080L1200ACU PN4060L1200C Main Lug 200 Copper<br />

1 Indoor P4080L1200ACUW PN4060L1200CW Main Lug 200 Copper<br />

1 Indoor P4080L1200AW PN4040L1200W Main Lug 200 Aluminum<br />

1 Indoor P4260B1225CU PN4264B1225C Main Breaker 225 Copper<br />

1 Indoor P4260B1225CUW PN4264B1225CW Main Breaker 225 Copper<br />

1-34<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Load Centers<br />

Cross Reference<br />

Phase Enclosure Legacy Catalog Number New Catalog Number Main Amperage Bus<br />

1 Indoor P4260L1225CU PN4264L1225C Main Lug 225 Copper<br />

1 Indoor P4260L1225CUSG PN4264L1225C Main Lug 225 Copper<br />

1 Indoor P4260L1225CUW PN4264L1225CW Main Lug 225 Copper<br />

1 Indoor P4280B1225ACU PN4264B1225C Main Breaker 225 Copper<br />

1 Indoor P4280B1225ACUW PN4264B1225CW Main Breaker 225 Copper<br />

1 Indoor P4280L1225ACU PN4264L1225C Main Lug 225 Copper<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

1 Indoor P4280L1225ACUW PN4264L1225CW Main Lug 225 Copper<br />

1 Indoor P5470B1200CU PN5482B1200C Main Breaker 200 Copper<br />

1 Indoor P5470B1200CUW PN5482B1200CW Main Breaker 200 Copper<br />

1 Indoor P5470B1225CU PN5482B1225C Main Breaker 225 Copper<br />

1 Indoor P5470L1225CU PN5482L1225C Main Lug 225 Copper<br />

1 Indoor P5480B1200ACU PN5482B1200C Main Breaker 200 Copper<br />

1 Indoor P5480B1200ACUW PN5482B1200CW Main Breaker 200 Copper<br />

1 Indoor P5480B1225ACU PN5482B1225C Main Breaker 225 Copper<br />

1 Indoor P5480B1225ACUW PN5482B1225CW Main Breaker 225 Copper<br />

1 Indoor P5480L1225ACU PN5482L1225C Main Lug 225 Copper<br />

1 Indoor P5480L1225ACUW PN5482L1225CW Main Lug 225 Copper<br />

1 Outdoor PW0816B1150TC PNW0816B1150TC Main Breaker 150 Copper<br />

1 Outdoor PW0816B1200TC PNW0816B1200TC Main Breaker 200 Copper<br />

1 Outdoor PW0816L1200TC PNW0816L1200TC Main Lug 200 Copper<br />

1 Outdoor PW1212L1125CU PNW1212L1125C Main Lug 125 Copper<br />

1 Outdoor PW1224B1100CU PNW1224B1100C Main Breaker 100 Copper<br />

1 Outdoor PW1224L1125CU PNW1224L1125C Main Lug 125 Copper<br />

1 Outdoor PW1224L1200CU PNW1224L1200C Main Lug 200 Copper<br />

1 Outdoor PW1224L1225CU PNW1224L1225C Main Lug 225 Copper<br />

1 Outdoor PW1624B1100CU PNW1632B1100C Main Breaker 100 Copper<br />

1 Outdoor PW1624L1125CU PNW1632L1125C Main Lug 125 Copper<br />

1 Outdoor PW2020B1100CU PNW2020B1100C Main Breaker 100 Copper<br />

1 Outdoor PW2030B1150CU PNW2040B1150C Main Breaker 150 Copper<br />

1 Outdoor PW2030L1150CU PNW2040L1150C Main Lug 150 Copper<br />

1 Outdoor PW2040B1200CU PNW2040B1200C Main Breaker 200 Copper<br />

1 Outdoor PW2040L1200CU PNW2040L1200C Main Lug 200 Copper<br />

1 Outdoor PW3040B1100CU PNW3048B1100C Main Breaker 100 Copper<br />

1 Outdoor PW3040B1125CU PNW3048B1125C Main Breaker 125 Copper<br />

1 Outdoor PW3040B1150CU PNW3048B1150C Main Breaker 150 Copper<br />

1 Outdoor PW3040B1200CU PNW3048B1200C Main Breaker 200 Copper<br />

1 Outdoor PW3040L1125CU PNW3048L1125C Main Lug 125 Copper<br />

1 Outdoor PW3040L1200CU PNW3048L1200C Main Lug 200 Copper<br />

1 Outdoor PW3054L1200CU PNW3048L1200C Main Lug 200 Copper<br />

1 Outdoor PW4040B1200CU PNW4040B1200C Main Breaker 200 Copper<br />

1 Outdoor PW4040L1200CU PNW4040L1200C Main Lug 200 Copper<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-35


Load Centers<br />

Cross Reference<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Phase Enclosure Legacy Catalog Number New Catalog Number Main Amperage Bus<br />

1 Outdoor PW4260B1225CU PNW4264B1225C Main Breaker 225 Copper<br />

1 Outdoor PW4260L1225CU PNW4264L1225C Main Lug 225 Copper<br />

1 Indoor S1020B1100 SN1224B1100 Main Breaker 100 Aluminum<br />

1 Indoor S1212L1125 SN1212L1125 Main Lug 125 Aluminum<br />

1 Indoor S1224B1100 SN1224B1100 Main Breaker 100 Aluminum<br />

1 Indoor S1224L1125 SN1224L1125 Main Lug 125 Aluminum<br />

1 Indoor S1224L1200 SN1224L1200 Main Lug 200 Aluminum<br />

1 Indoor S1624B1100 SN1632B1100 Main Breaker 100 Aluminum<br />

1 Indoor S1624B1100W SN1632B1100W Main Breaker 100 Aluminum<br />

1 Indoor S1624B1125 SN1632B1125 Main Breaker 125 Aluminum<br />

1 Indoor S1624L1125 SN1632L1125 Main Lug 125 Aluminum<br />

1 Indoor S1630B1150 SN1632B1150 Main Breaker 150 Aluminum<br />

1 Indoor S1632B1200 SN1632B1200 Main Breaker 200 Aluminum<br />

1 Indoor S2020B1100 SN2020B1100 Main Breaker 100 Aluminum<br />

1 Indoor S2020B1100P SN2020B1100P1 Main Breaker 100 Aluminum<br />

1 Indoor S2020L1125 SN2020L1125 Main Lug 125 Aluminum<br />

1 Indoor S2020L1125G SN2020L1125 Main Lug 125 Aluminum<br />

1 Indoor S2020L1125GW SN2020L1125W Main Lug 125 Aluminum<br />

1 Indoor S2020L1125W SN2020L1125W Main Lug 125 Aluminum<br />

1 Indoor S2024B1100 SN2040B1100 Main Breaker 100 Aluminum<br />

1 Indoor S2024L1125 SN2040L1125 Main Lug 125 Aluminum<br />

1 Indoor S2024L1125G SN2040L1125 Main Lug 125 Aluminum<br />

1 Indoor S2030B1150 SN2040B1150 Main Breaker 150 Aluminum<br />

1 Indoor S2030L1125SG SN2040L1125 Main Lug 125 Aluminum<br />

1 Indoor S2030L1150 SN2040L1150 Main Lug 150 Aluminum<br />

1 Indoor S2030L1150W SN2040L1150W Main Lug 150 Aluminum<br />

1 Indoor S2040B1100A SN2040B1100 Main Breaker 100 Aluminum<br />

1 Indoor S2040B1100AW SN2040B1100W Main Breaker 100 Aluminum<br />

1 Indoor S2040B1150A SN2040B1150 Main Breaker 150 Aluminum<br />

1 Indoor S2040B1150AW SN2040B1150W Main Breaker 150 Aluminum<br />

1 Indoor S2040B1200 SN2040B1200 Main Breaker 200 Aluminum<br />

1 Indoor S2040B1200A SN2040B1200 Main Breaker 200 Aluminum<br />

1 Indoor S2040B1200AW SN2040B1200W Main Breaker 200 Aluminum<br />

1 Indoor S2040C1200 SN2040C1200 Main Convertible 200 Aluminum<br />

1 Indoor S2040L1125AG SN2040L1125 Main Lug 125 Aluminum<br />

1 Indoor S2040L1125AGW SN2040L1125W Main Lug 125 Aluminum<br />

1 Indoor S2040L1150AG SN2040L1150 Main Lug 150 Aluminum<br />

1 Indoor S2040L1150AGW SN2040L1150W Main Lug 150 Aluminum<br />

1 Indoor S2040L1200 SN2040L1200 Main Lug 200 Aluminum<br />

1 Indoor S2040L1200AG SN2040L1200 Main Lug 200 Aluminum<br />

1 Indoor S2040L1200AGW SN2040L1200W Main Lug 200 Aluminum<br />

1-36<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Load Centers<br />

Cross Reference<br />

Phase Enclosure Legacy Catalog Number New Catalog Number Main Amperage Bus<br />

1 Indoor S2424B1125 SN2424B1125 Main Breaker 125 Aluminum<br />

1 Indoor S2424B1125W SN2424B1125W Main Breaker 125 Aluminum<br />

1 Indoor S2424C1125 SN2424C1125 Main Convertible 125 Aluminum<br />

1 Indoor S2424L1125 SN2424L1125 Main Lug 125 Aluminum<br />

1 Indoor S2424L1125G SN2424L1125 Main Lug 125 Aluminum<br />

1 Indoor S2424L1125GW SN2424L1125W Main Lug 125 Aluminum<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

1 Indoor S2424L1125W SN2424L1125W Main Lug 125 Aluminum<br />

1 Indoor S2430B1150 SN2448B1150 Main Breaker 150 Aluminum<br />

1 Indoor S2440B1200 SN2448B1200 Main Breaker 200 Aluminum<br />

1 Indoor S2440L1125 SN2448L1125 Main Lug 125 Aluminum<br />

1 Indoor S2440L1125G SN2448L1125 Main Lug 125 Aluminum<br />

1 Indoor S2440L1200 SN2448L1200 Main Lug 200 Aluminum<br />

1 Indoor S2440L1200W SN2448L1200W Main Lug 200 Aluminum<br />

1 Indoor S2448B1125A SN2424B1125 Main Breaker 125 Aluminum<br />

1 Indoor S2448B1125AW SN2424B1125W Main Breaker 125 Aluminum<br />

1 Indoor S2448B1150A SN2448B1150 Main Breaker 150 Aluminum<br />

1 Indoor S2448B1150AW SN2448B1150W Main Breaker 150 Aluminum<br />

1 Indoor S2448B1200A SN2448B1200 Main Breaker 200 Aluminum<br />

1 Indoor S2448B1200AW SN2448B1200W Main Breaker 200 Aluminum<br />

1 Indoor S2448L1125AG SN2448L1125 Main Lug 125 Aluminum<br />

1 Indoor S2448L1125AGW SN2448L1125W Main Lug 125 Aluminum<br />

1 Indoor S2448L1200AG SN2448L1200 Main Lug 200 Aluminum<br />

1 Indoor S2448L1200AGW SN2448L1200W Main Lug 200 Aluminum<br />

1 Indoor S3030B1100 SN3030B1100 Main Breaker 100 Aluminum<br />

1 Indoor S3030B1100W SN3030B1100W Main Breaker 100 Aluminum<br />

1 Indoor S3030B1125 SN3030B1125 Main Breaker 125 Aluminum<br />

1 Indoor S3030B1125W SN3030B1125W Main Breaker 125 Aluminum<br />

1 Indoor S3030B1150 SN3030B1150 Main Breaker 150 Aluminum<br />

1 Indoor S3030B1150SG SN3030B1150 Main Breaker 150 Aluminum<br />

1 Indoor S3030B1150W SN3030B1150W Main Breaker 150 Aluminum<br />

1 Indoor S3030L1200 SN3030L1200 Main Lug 200 Aluminum<br />

1 Indoor S3030L1200W SN3030L1200W Main Lug 200 Aluminum<br />

1 Indoor S3040B1125 SN3048B1125 Main Breaker 125 Aluminum<br />

1 Indoor S3040B1150 SN3048B1150 Main Breaker 150 Aluminum<br />

1 Indoor S3040B1200 SN3048B1200 Main Breaker 200 Aluminum<br />

1 Indoor S3040B1200P SN3048B1200P1 Main Breaker 200 Aluminum<br />

1 Indoor S3040B1200W SN3048B1200W Main Breaker 200 Aluminum<br />

1 Indoor S3040C1200 SN3048C1200 Main Convertible 200 Aluminum<br />

1 Indoor S3040L1125 SN3048L1125 Main Lug 125 Aluminum<br />

1 Indoor S3040L1125G SN3048L1125 Main Lug 125 Aluminum<br />

1 Indoor S3040L1125GW SN3048L1125W Main Lug 125 Aluminum<br />

1 Indoor S3040L1125W SN3048L1125W Main Lug 125 Aluminum<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-37


Load Centers<br />

Cross Reference<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Phase Enclosure Legacy Catalog Number New Catalog Number Main Amperage Bus<br />

1 Indoor S3040L1200 SN3048L1200 Main Lug 200 Aluminum<br />

1 Indoor S3040L1200L50 SN3048L1200L50 Main Lug 200 Aluminum<br />

1 Indoor S3040L1200L50W SN3048L1200L5W Main Lug 200 Aluminum<br />

1 Indoor S3040L1200P SN3048B1200P1 Main Lug 200 Aluminum<br />

1 Indoor S3040L1200W SN3048L1200W Main Lug 200 Aluminum<br />

1 Indoor S3054B1200P SN3048B1200P1 Main Breaker 200 Aluminum<br />

1 Indoor S3054B1200S060 SN3048B1200S06 Main Breaker 200 Aluminum<br />

1 Indoor S3054L1200 SN3048L1200 Main Lug 200 Aluminum<br />

1 Indoor S3060B1100A SN3048B1100 Main Breaker 100 Aluminum<br />

1 Indoor S3060B1100AW SN3048B1100W Main Breaker 100 Aluminum<br />

1 Indoor S3060B1125A SN3048B1125 Main Breaker 125 Aluminum<br />

1 Indoor S3060B1125AW SN3048B1125W Main Breaker 125 Aluminum<br />

1 Indoor S3060B1150A SN3048B1150 Main Breaker 150 Aluminum<br />

1 Indoor S3060B1150AW SN3048B1150W Main Breaker 150 Aluminum<br />

1 Indoor S3060B1200A SN3048B1200 Main Breaker 200 Aluminum<br />

1 Indoor S3060B1200AW SN3048B1200W Main Breaker 200 Aluminum<br />

1 Indoor S3060L1125AG SN3048L1125 Main Lug 125 Aluminum<br />

1 Indoor S3060L1125AGW SN3048L1125W Main Lug 125 Aluminum<br />

1 Indoor S3060L1200AG SN3048L1200 Main Lug 200 Aluminum<br />

1 Indoor S3060L1200AGW SN3048L1200W Main Lug 200 Aluminum<br />

1 Indoor S4040B1200 SN4040B1200 Main Breaker 200 Aluminum<br />

1 Indoor S4040B1200P SN4040B1200P1 Main Breaker 200 Aluminum<br />

1 Indoor S4040B1200SG SN4040B1200 Main Breaker 200 Aluminum<br />

1 Indoor S4040B1200W SN4040B1200W Main Breaker 200 Aluminum<br />

1 Indoor S4040C1200 SN4040C1200 Main Convertible 200 Aluminum<br />

1 Indoor S4040L1125 SN4040L1125 Main Lug 125 Aluminum<br />

1 Indoor S4040L1200 SN4040L1200 Main Lug 200 Aluminum<br />

1 Indoor S4040L1200W SN4040L1200W Main Lug 200 Aluminum<br />

1 Indoor S4060B1200S060 SN4060B1200S06 Main Breaker 200 Aluminum<br />

1 Indoor S4080B1200A SN4060B1200 Main Breaker 200 Aluminum<br />

1 Indoor S4080B1200AW SN4060B1200W Main Breaker 200 Aluminum<br />

1 Indoor S4080L1125AG SN4040L1125 Main Lug 125 Aluminum<br />

1 Indoor S4080L1125AGW SN4040L1125W Main Lug 125 Aluminum<br />

1 Indoor S4080L1200AG SN4040L1200 Main Lug 200 Aluminum<br />

1 Indoor S4080L1200AGW SN4040L1200W Main Lug 200 Aluminum<br />

1 Indoor S4260B1200 SN4264B1200 Main Breaker 200 Aluminum<br />

1 Indoor S4260B1225 SN4264B1225 Main Breaker 225 Aluminum<br />

1 Indoor S4260L1225 SN4264L1225 Main Lug 225 Aluminum<br />

1 Indoor S4280B1225A SN4264B1225 Main Breaker 225 Aluminum<br />

1 Indoor S4280B1225AW SN4264B1225W Main Breaker 225 Aluminum<br />

1 Indoor S4280L1225AG SN4264L1225 Main Lug 225 Aluminum<br />

1 Indoor S4280L1225AGW SN4264L1225W Main Lug 225 Aluminum<br />

1-38<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Load Centers<br />

Cross Reference<br />

Phase Enclosure Legacy Catalog Number New Catalog Number Main Amperage Bus<br />

1 Indoor S5470B1200 SN5482B1200 Main Breaker 200 Aluminum<br />

1 Indoor S5470B1225 SN5482B1225 Main Breaker 225 Aluminum<br />

1 Indoor S5470L1225 SN5482L1225 Main Lug 225 Aluminum<br />

1 Indoor S5480B1200A SN5482B1200 Main Breaker 200 Aluminum<br />

1 Indoor S5480B1200AW SN5482B1200W Main Breaker 200 Aluminum<br />

1 Indoor S5480B1225A SN5482B1225 Main Breaker 225 Aluminum<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

1 Indoor S5480B1225AW SN5482B1225W Main Breaker 225 Aluminum<br />

1 Indoor S5480L1225AG SN5482L1225 Main Lug 225 Aluminum<br />

1 Indoor S5480L1225AGW SN5482L1225W Main Lug 225 Aluminum<br />

1 Outdoor SW0816B1200T SNW0816B1200T Main Breaker 200 Aluminum<br />

1 Outdoor SW0816L1200T SNW0816L1200T Main Lug 200 Aluminum<br />

1 Outdoor SW1212L1125 SNW1212L1125 Main Lug 125 Aluminum<br />

1 Outdoor SW1224B1100 SNW1224B1100 Main Breaker 100 Aluminum<br />

1 Outdoor SW1224B1125 SNW1224B1125 Main Breaker 125 Aluminum<br />

1 Outdoor SW1224L1125 SNW1224L1125 Main Lug 125 Aluminum<br />

1 Outdoor SW1224L1200 SNW1224L1200 Main Lug 200 Aluminum<br />

1 Outdoor SW1224L1225 SNW1224L1225 Main Lug 225 Aluminum<br />

1 Outdoor SW1624B1100 SNW1632B1100 Main Breaker 100 Aluminum<br />

1 Outdoor SW1624L1125 SNW1632L1125 Main Lug 125 Aluminum<br />

1 Outdoor SW2020B1100 SNW2020B1100 Main Breaker 100 Aluminum<br />

1 Outdoor SW2024B1125 SNW2040B1125 Main Breaker 125 Aluminum<br />

1 Outdoor SW2030L1150 SNW2040L1150 Main Lug 150 Aluminum<br />

1 Outdoor SW2040B1200 SNW2040B1200 Main Breaker 200 Aluminum<br />

1 Outdoor SW2040C1200 SNW2040C1200 Main Convertible 200 Aluminum<br />

1 Outdoor SW2040L1200 SNW2040L1200 Main Lug 200 Aluminum<br />

1 Outdoor SW2424B1125 SNW2424B1125 Main Breaker 125 Aluminum<br />

1 Outdoor SW2424C1125 SNW2424C1125 Main Convertible 125 Aluminum<br />

1 Outdoor SW2424L1125 SNW2424L1125 Main Lug 125 Aluminum<br />

1 Outdoor SW3040B1125 SNW3048B1125 Main Breaker 125 Aluminum<br />

1 Outdoor SW3040B1150 SNW3048B1150 Main Breaker 150 Aluminum<br />

1 Outdoor SW3040B1200 SNW3048B1200 Main Breaker 200 Aluminum<br />

1 Outdoor SW3040C1200 SNW3048C1200 Main Convertible 200 Aluminum<br />

1 Outdoor SW3040L1125 SNW3048L1125 Main Lug 125 Aluminum<br />

1 Outdoor SW3040L1200 SNW3048L1200 Main Lug 200 Aluminum<br />

1 Outdoor SW3054L1200 SNW3048L1200 Main Lug 200 Aluminum<br />

1 Outdoor SW4040B1150 SNW4040B1150 Main Breaker 150 Aluminum<br />

1 Outdoor SW4040B1200 SNW4040B1200 Main Breaker 200 Aluminum<br />

1 Outdoor SW4040C1200 SNW4040C1200 Main Convertible 200 Aluminum<br />

1 Outdoor SW4040L1200 SNW4040L1200 Main Lug 200 Aluminum<br />

1 Outdoor SW4260B1225 SNW4264B1225 Main Breaker 225 Aluminum<br />

1 Outdoor SW4260L1225 SNW4264L1225 Main Lug 225 Aluminum<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-39


Circuit Breakers<br />

Arc-Fault and Ground-Fault Breakers<br />

Revised on 01/31/20<br />

Selection<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Arc-Fault Circuit Interrupters (AFCI)<br />

AFCI’s detect arcing faults (an unintentional arcing condition in a circuit) that<br />

standard circuit breakers are not designed to detect. The device is intended to<br />

mitigate the effects of arcing faults by functioning to de-energize the circuit when<br />

an arc-fault is detected.<br />

Combination Type AFCI<br />

Detects all three possible types of arc faults: line-to-ground, line-to-neutral, and series.<br />

Breaker<br />

Type<br />

QAF2/QAFH2/HQAF2<br />

1-Pole 120V AC<br />

QAF/QAFH<br />

2-Pole 120/240V AC<br />

QAF2N<br />

Plug-on Neutral/1-Pole 120V AC<br />

QAF/QAFH<br />

Plug-on Neutral/2-Pole 120/240V AC<br />

Amp<br />

Rating<br />

15<br />

20<br />

15<br />

20<br />

QAF2/QPF/QE/QPF2 Accessories<br />

10,000 A IR<br />

Catalog No.<br />

QA115AFC <br />

QA120AFC <br />

Q215AFC <br />

Q220AFC <br />

22,000 A IR<br />

Catalog No.<br />

QA115AFCH <br />

QA120AFCH <br />

Q215AFCHn —<br />

Q220AFCHn —<br />

15 QA115AFCN — —<br />

20 QA120AFCN — —<br />

15 Q215AFCN — —<br />

20 Q220AFCN — —<br />

65,000 A IR<br />

Catalog No.<br />

QA115AFCHHn <br />

QA120AFCHHn <br />

Dual Function AFCI/GFCI<br />

The Dual Function Circuit Breaker combines Combination Type AFCI and 5mA GFCI<br />

protection in one device. The device includes the Self Test feature, making it the first in<br />

class in electrical safety for homeowners.<br />

QFGA2/QFGAH2/HQFGA2<br />

1-Pole 120V AC<br />

QFGA2N<br />

Plug-on Neutral/1-Pole 120V AC<br />

Description<br />

Padlocking Device 1-Pole<br />

Padlocking Device 2-Pole<br />

Handle Block<br />

15<br />

20<br />

Q115DF <br />

Q120DF <br />

Q115DFHn <br />

Q120DFH <br />

15 Q115DFN — —<br />

20 Q120DFN — —<br />

Ground-Fault Circuit Interrupters (GFCI)<br />

Catalog Number <br />

ECPLD1<br />

ECPLD2<br />

ECBX231M<br />

Q115DFHHn <br />

Q120DFHHn <br />

Provides Class A (5mA) ground fault protection. Intended for personnel protection.<br />

Includes Self Test as an added safety feature.<br />

Breaker Type<br />

QPF2/QPHF2/HQPF2<br />

1-Pole 120V AC<br />

QPF/QPHF<br />

2-Pole 120/240V AC<br />

QPF2N<br />

Plug-on Neutral/1-Pole 120V AC<br />

Amp<br />

Rating<br />

15<br />

20<br />

30<br />

15<br />

20<br />

30<br />

40<br />

50<br />

60<br />

10,000 A IR<br />

Catalog No.<br />

QF115A a<br />

QF120A a<br />

QF130A a<br />

QF215A<br />

QF220A<br />

QF230A<br />

QF240A<br />

QF250A<br />

QF260A<br />

22,000 A IR<br />

Catalog No.<br />

QF115AHn a<br />

QF120AHn a<br />

QF130AHn a<br />

QF215AHn<br />

QF220AHn<br />

QF230AHn<br />

QF240AHn<br />

QF250AHn<br />

QF260AHn<br />

15 QF115AN — —<br />

20 QF120AN — —<br />

30 QF130AN — —<br />

Ground Fault Equipment Protection (30mA)<br />

Provides protection of equipment from damaging line-to-ground faults currents.<br />

QE/QEH<br />

1-Pole 120V AC<br />

QE/QEH<br />

2-Pole 120/240V AC<br />

15<br />

20<br />

30<br />

15<br />

20<br />

30<br />

40<br />

50<br />

60<br />

QE115<br />

QE120<br />

QE130<br />

QE215<br />

QE220<br />

QE230<br />

QE240<br />

QE250<br />

QE260<br />

QE115Hn<br />

QE120Hn<br />

QE130Hn<br />

QE215Hn<br />

QE220Hn<br />

QE230Hn<br />

QE240Hn<br />

QE250Hn<br />

QE260Hn<br />

65,000 A IR<br />

Catalog No.<br />

QF115AHHn a<br />

QF120AHHn a<br />

QF130AHHn a<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

n Built to order. Allow 8 -10 weeks for delivery.<br />

a UL Listed as SWD (Switching Duty) Rated, suitable<br />

for 120V AC Fluorescent Lighting.<br />

1-Pole Combination<br />

Type AFCI<br />

1-Pole Dual<br />

Function AFCI/GFC<br />

1-Pole AFCI<br />

Plug-on Neutral<br />

1-Pole GFCI<br />

1-Pole Equipment<br />

Protection<br />

2-Pole Combination<br />

Type AFCI<br />

1-Pole Dual Function<br />

Plug-on Neutral<br />

2-Pole GFCI<br />

2-Pole Equipment<br />

Protection<br />

1-40<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Circuit Breakers<br />

Revised on 10/31/18<br />

Type QP with INSTA-WIRE<br />

Continuous Current<br />

Rating @ 40° C<br />

Type QP Type QPH Type HQP<br />

10,000A IR 22,000A IR 65,000A IR<br />

Catalog Number Catalog Number Catalog Number<br />

1-Pole Plug-In (120/240V AC) e<br />

10 Q110 — —<br />

15 Q115c Q115H c Q115HHn c<br />

20 Q120c Q120H c Q120HHn c<br />

25 Q125 Q125Hn Q125HHn<br />

30 Q130 Q130H Q130HHn<br />

35 Q135n Q135Hn Q135HHn<br />

40 Q140 Q140H Q140HHn<br />

45 Q145n Q145Hn Q145HHn<br />

50 Q150 Q150H Q150HHn<br />

60 Q160 Q160Hn Q160HHn<br />

70 Q170 Q170Hn Q170HHn<br />

2-Pole Plug-In (Common-Trip 120/240V AC) <br />

10 Q210 — —<br />

15 Q215 Q215H Q215HH<br />

20 Q220 Q220H Q220HH<br />

25 Q225 Q225Hn Q225HHn<br />

30 Q230 Q230H Q230HH<br />

35 Q235 Q235Hn Q235HHn<br />

40 Q240 Q240H Q240HHn<br />

45 Q245 Q245Hn Q245HHn<br />

50 Q250 Q250H Q250HH<br />

60 Q260 Q260H Q260HH<br />

70 Q270 Q270H Q270HH<br />

80 Q280 Q280Hn Q280HHn<br />

90 Q290 Q290H Q290HHn<br />

100 Q2100 Q2100H Q2100HH<br />

110 Q2110 Q2110H Q2110HHn<br />

125 Q2125 Q2125H Q2125HH<br />

2-Pole Plug-In (Common-Trip 240V AC) <br />

15 Q215R — —<br />

20 Q220R — —<br />

30 Q230R — —<br />

40 Q240R — —<br />

50 Q250R — —<br />

3-Pole Plug-In (Common-Trip 240V AC) <br />

15 Q315 Q315H Q315HHn<br />

20 Q320 Q320H Q320HH<br />

25 Q325 Q325Hn Q325HHn<br />

30 Q330 Q330H Q330HH<br />

35 Q335 Q335Hn Q335HHn<br />

40 Q340 Q340H Q340HH<br />

45 Q345 Q345Hn Q345HHn<br />

50 Q350 Q350H Q350HH<br />

60 Q360 Q360H Q360HH<br />

70 Q370 Q370H Q370HHn<br />

80 Q380 Q380H Q380HHn<br />

90 Q390 Q390H Q390HHn<br />

100 Q3100 Q3100H Q3100HH<br />

Q120<br />

Q220<br />

Q320<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

QP / QPH / HQP Internal Accessories<br />

Control Voltage AC Catalog Number Field/Factory Installed<br />

120V Shunt Trip add suffix …00S01n Factory<br />

24V Shunt Trip add suffix …00S07n Factory<br />

120V Auxiliary Switch add suffix …01n b Factory<br />

Modifications<br />

Description<br />

Catalog Number<br />

400 Hz Calibration add suffix …Y h<br />

Marine 50˚C Ambient<br />

Calibration<br />

add suffix …M<br />

Fungus Proofing add suffix …F<br />

For external accessories<br />

please refer to page 1-48.<br />

n Built to order. Allow 2-3 weeks for delivery.<br />

a UL Listed for use with 60/75° wire through 40 amps,<br />

UL listed for use with 75° wire only for 50 amps<br />

and above, HACR rated.<br />

\b 1A and 1B contacts.<br />

c UL Listed for frequent switching applications (SWD).<br />

120V AC Fluorescent Lighting.<br />

d UL Listed for use on 3-phase grounded “B” systems —<br />

10,000 for this application.<br />

e Shipped 12 per sleeve.<br />

f Shipped 6 per sleeve.<br />

g Shipped 4 per sleeve.<br />

h UL Listed 5 KA IR.<br />

i Type QP1, UL listed for 16 AWG conductors and<br />

multiple wires.<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-41


Circuit Breakers<br />

Duplex, Triplex and Quadplex Plug-In Breakers<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Duplex Circuit Breakers<br />

Breaker Type<br />

QT<br />

1-Pole<br />

10K AIC<br />

120V AC<br />

Triplex Circuit Breakers<br />

Breaker<br />

Type<br />

QT<br />

2-Pole<br />

10K AIC<br />

120/240V AC<br />

Inner Poles<br />

Common Trip<br />

Ampere<br />

Rating Catalog Number Catalog Number<br />

15–15 Q1515 Q1515NC a<br />

15–20 Q1520 Q1520NC a<br />

20–20 Q2020 Q2020NC a<br />

20–30 Q2030 —<br />

30–15n Q3015 —<br />

30–20 Q3020 —<br />

30–30 Q3030 Q3030NC a<br />

SHIPPING: 12 per carton, (Wt. 4.8 lbs.)<br />

Ampere Rating<br />

Single Pole<br />

Common-Trip<br />

2-Pole<br />

Catalog<br />

Number<br />

15 15 Q21515CT<br />

15 20 Q21520CT<br />

15 25 Q21525CTn<br />

15 30 Q21530CT<br />

15 35 Q21535CTn<br />

15 40 Q21540CT<br />

15 45 Q21545CTn<br />

15 50 Q21550CT<br />

20 20 Q22020CT<br />

20 25 Q22025CTn<br />

20 30 Q22030CT<br />

20 35 Q22035CTn<br />

20 40 Q22040CT<br />

20 45 Q22045CTn<br />

20 50 Q22050CT<br />

30 30 Q23030CT<br />

SHIPPING: 6 per carton, (Wt. 4.9 lbs.)<br />

QT Duplex<br />

These space saver duplex breakers combine two<br />

independent 1/2" breaker poles in a common unit.<br />

This unit plugs into one load center stab and<br />

requires one panel space. HACR rated.<br />

QT Triplex<br />

These space saver triplex breakers provide<br />

a 2-pole common trip breaker for 120/240V AC<br />

circuits and two single poles for 120V AC circuits.<br />

Triplex require two panel spaces. HACR rated.<br />

Quadplex Circuit Breakers<br />

Ampere Rating<br />

Breaker<br />

Type<br />

QT<br />

2-Pole<br />

10K AIC<br />

120/240V AC<br />

Inner and<br />

Outter 2 Poles<br />

Common Trip<br />

Common-Trip<br />

2-Pole Outside<br />

Common-Trip<br />

2-Pole Inside<br />

Catalog<br />

Number<br />

15 15 Q21515CT2<br />

15 30 Q21530CT2<br />

20 20 Q22020CT2<br />

20 50 Q22050CT2<br />

30 20 Q23020CT2<br />

30 25 Q23025CT2<br />

30 30 Q23030CT2<br />

30 50 Q23050CT2<br />

40 20 Q24020CT2<br />

40 30 Q24030CT2<br />

40 40 Q24040CT2<br />

SHIPPING: 6 per carton, (Wt. 4.8 lbs.)<br />

QT Quadplex<br />

These space saver quadplex breakers provide<br />

two sets of common trip, two-pole breakers for<br />

120/240V AC circuits, and require two panel<br />

spaces. HACR rated.<br />

For external accessories,<br />

please refer to page 1-48.<br />

For inches / millimeters conversion, see Application Data<br />

section.<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

a Non-CTL. For replacement use only in panels manufactured<br />

before 1968<br />

1-42<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Circuit Breakers<br />

Special Application Breakers<br />

HID Lighting<br />

For high-intensity discharge lamp loads having in-rush currents<br />

above the instantaneous trip setting of a standard breaker.<br />

Breaker<br />

Type<br />

QP<br />

1-Pole<br />

120V AC<br />

QP<br />

2-Pole<br />

120/240V AC<br />

Wiring<br />

Diagram<br />

Figure 1<br />

Figure 2<br />

Complete Breaker UL Unenclosed<br />

Ampere Rating Catalog Number<br />

15 Q115HID a n<br />

20 Q120HID a<br />

30 Q130HID<br />

15 Q215HID<br />

20 Q220HIDn<br />

30 Q230HIDn<br />

Molded Case Switch<br />

For applications that do not require overcurrent protection.<br />

QP<br />

1-Pole<br />

120V AC<br />

QP<br />

2-Pole<br />

120/240V AC<br />

Figure 1 100 Q1100S<br />

Figure 2<br />

30<br />

50<br />

60<br />

125<br />

Q230S<br />

Q250S<br />

Q260S<br />

Q2125S<br />

Switching Neutral<br />

Figure 1 Figure 2<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

No-Noise<br />

For applications that require a reduction in the 60-cycle hum of<br />

a standard breaker.<br />

Figure 3 Figure 4<br />

QP<br />

2-Pole<br />

120/240V AC<br />

Figure 2<br />

50<br />

60<br />

Q250NNn<br />

Q260NN<br />

Switching Neutrals<br />

Used where all conductors are required to be disconnected.<br />

Neutral pole of the circuit breaker does not connect to load<br />

center bus. One side is wired to neutral and the other side to<br />

the device.<br />

QG<br />

2-Wire<br />

Common Trip<br />

120V AC<br />

QG<br />

3-Wire<br />

Common Trip<br />

120/240V AC<br />

Figure 3<br />

15<br />

20<br />

QG215<br />

QG220<br />

Figure 4 20 QG320<br />

Wiring Diagrams<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

Note: All circuit breakers on this page are 10K AIC<br />

a UL Listed as SWD (Switching Duty) Rated, suitable for 120V AC Fluorescent Lighting.<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-43


Circuit Breakers<br />

3/4 Inch Plug-In Breakers<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Features<br />

n 3/4" format<br />

n HACR Rated<br />

n UL Classified for use in certain Square D<br />

load centers<br />

Type QD Circuit Breakers<br />

The Type QD circuit breaker line is<br />

available in 1-pole and 2-pole common<br />

trip versions listed on this page.<br />

The circuit breakers are UL Classified<br />

and UL Listed.<br />

All QD breakers are supplied with load<br />

side connectors suitable for 60/75°C<br />

wire and are calibrated for 40°C<br />

maximum ambient applications.<br />

UL Classified<br />

Siemens Type QD circuit breakers are<br />

UL Classified for use in specific Square<br />

D load centers in place of Square D Type<br />

QO ® circuit breakers. A Panelboard<br />

Compatibility List packaged with each<br />

QD breaker shows which type QD<br />

circuit breakers are acceptable for<br />

use in Square D load centers.<br />

The interrupting rating on these circuit<br />

breakers is 10,000A IR maximum and<br />

they are not series rated with Square D<br />

circuit breakers or equipment. This UL<br />

Classification allows a Siemens Type QD<br />

circuit breaker to be used in place of a<br />

Square D Type QO circuit breaker in<br />

those load centers that are specifically<br />

shown on the Panelboard Compatibility<br />

list. For additional information, contact<br />

your local Siemens sales engineer.<br />

Shipping Weights<br />

Number of Number Per Shipping<br />

Poles Carton Weight (lbs.)<br />

1 16 3.8<br />

2 8 4.2<br />

Panelboard Compatibility List<br />

Listed Panelboards—Square D—Catalog Numbers<br />

QO2L30F/S<br />

QO2-4L70F/S<br />

QO2-4L70TS<br />

QO2-4L70RB<br />

QO6-12L100F/S<br />

QO6-12L100DF/S<br />

QO6-12L100TF/S<br />

QO6-12L100DTF/S<br />

QO6-12L100RB<br />

QO8-16L100F/S<br />

QO8-16L100DF/S<br />

QO8-16L100TF/S<br />

QO8-16L100DTF/S<br />

QO8-16L100RB<br />

QO112M100/RB<br />

QO116M100/RB<br />

QO120M100/RB<br />

QO124M100<br />

QO12L100DF/S<br />

QO12L100RB<br />

QO12-20M100/RB<br />

QO12-20M100TF/S<br />

D120<br />

1-Pole<br />

2-Pole<br />

Continuous<br />

Current Rating 120V<br />

120/240V Common Trip<br />

@ 40°C<br />

Catalog Number<br />

Catalog Number<br />

15 D115 a D215<br />

20 D120 a D220<br />

30 D130 D230<br />

40 D140 D240<br />

50 D150 D250<br />

60 D160 D260<br />

QO12M100/RB<br />

QO16-20M100/RB<br />

QO16M100/RB<br />

QO20M100/RB<br />

QO112L125G/RB<br />

QO112-24L125G/RB<br />

QO112-24L125GWGC<br />

QO116L125G<br />

QO116-24L125G/RB<br />

QO12-24L125/RB<br />

QO120-24L125G<br />

QO120-24L125GWGC<br />

QO120L125G<br />

QO124L125G/RB<br />

QO124M125/RB<br />

QO16L125/RB<br />

QO16-12M125FTRB<br />

QO16-24L125/RB<br />

QO20L125/RB<br />

QO20-24L125/RB<br />

QO24L125/RB<br />

QO120-30L150G<br />

QO120-30M150/RB<br />

QO124L150G<br />

QO124M150<br />

QO130L150G/RB<br />

QO130M150/RB<br />

QO16L150/RB<br />

QO16M150/RB<br />

QO16-30L150/RB<br />

QO18-16M150FTRB<br />

QO20-30M150/RB<br />

QO20-30M150TF/S<br />

QO20-30L150<br />

QO24L150/RB<br />

QO24M150/RB<br />

QO30L150/RB<br />

QO30M150/RB<br />

QO8-16M200FT/RB<br />

QO112L200G/RB<br />

QO120-40M200/RB<br />

QO120-40M200TC<br />

QO124M200<br />

QO130L200G/RB<br />

D220<br />

QO130-40M200<br />

QO130M200/RB<br />

QO130-40L200G/RB<br />

QO140M200/RB<br />

QO16L200/RB<br />

QO16M200/RB<br />

QO18-16M200FTRB<br />

QO20-40L200/RB<br />

QO20-40M200TF/S<br />

QO20-40M200/RB<br />

QO24L200/RB<br />

QO24M200/RB<br />

QO30L200/RB<br />

QO30M200/RB<br />

QO30-40L200/RB<br />

QO30-40M200/RB<br />

QO40M200/RB<br />

QO140M225<br />

QO142L225G/RB<br />

For inches / millimeters conversion, see Application Data<br />

section.<br />

a UL Listed for frequent switching applications (SWD).<br />

120V AC Fluorescent Lighting. One or two load<br />

conductors.<br />

1-44<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Circuit Breakers<br />

Revised on 10/31/18<br />

Main and Branch Circuit Breakers <br />

Breaker<br />

Type<br />

QN<br />

2-Pole<br />

120/240V AC<br />

QNH<br />

2-Pole<br />

120/240V AC<br />

HQN<br />

2-Pole<br />

120/240V AC<br />

Ampere<br />

Rating<br />

Catalog<br />

Number<br />

Catalog<br />

Number<br />

150 QN2150 QN2150R b 10<br />

175 QN2175n QN2175R b n 10<br />

200 QN2200 QN2200R b 10<br />

150 QN2150H QN2150RH b 22<br />

175 QN2175Hn QN2175RH b n 22<br />

200 QN2200H QN2200RH b 22<br />

150 HQN2150 HQN2150R b 65<br />

175 HQN2175n — 65<br />

200 HQN2200 HQN2200R b 65<br />

UL Interrupting<br />

Ratings (kA)<br />

Requires 4 panel spaces, 2 adjacent and 2 opposite. SHIPPING: 1 per carton (Wt. 3 lbs.)<br />

QNR e<br />

QN e<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Main Breaker Kits<br />

For use in PL, ES, and Ult Load Centers d<br />

UL<br />

Type<br />

Ampere<br />

Rating<br />

Catalog<br />

Number<br />

For use in EQIII Load Centers<br />

UL<br />

Type<br />

Ampere<br />

Rating<br />

Catalog<br />

Number<br />

EQ8681 100 MBK100A EQ9675 100 MBK100 22<br />

EQ8682 125 MBK125A EQ9677 125 MBK125 22<br />

EQ8693 150 MBK150A EQ9683 150 MBK150 22<br />

— — — EQ9684 175 MBK175n 22<br />

EQ8695 200 MBK200A EQ9685 200 MBK200 22<br />

EQ8696 225 MBK225A EQ9686 225 MBK225 22<br />

UL Interrupting<br />

Ratings (kA)<br />

EQ9675<br />

Breaker<br />

Type<br />

QPJ c<br />

3-Pole<br />

240V AC<br />

Ampere<br />

Rating<br />

Catalog<br />

Number<br />

125 QPJ3125 10<br />

150 QPJ3150 10<br />

200 QPJ3200 10<br />

UL Interrupting<br />

Ratings (kA)<br />

Requires 6 spaces due to cross over design. Fits only EQIII 125-400A 3-phase<br />

load centers<br />

SHIPPING: 5 per carton (Wt. 17 lbs.)<br />

Breaker<br />

Type<br />

QPP<br />

2-Pole<br />

120/240V AC<br />

QPPH<br />

2-Pole<br />

120/240V AC<br />

HQPH<br />

2-Pole, 120/240V AC<br />

HQPP<br />

2-Pole<br />

120/240V AC<br />

HQPPH<br />

2-Pole<br />

120/240V AC<br />

Ampere<br />

Rating<br />

Catalog<br />

Number<br />

125 Q2125B 10<br />

150 Q2150B 10<br />

175 Q2175Bn 10<br />

200 Q2200B 10<br />

225 Q2225B 10<br />

125 Q2125BH 22<br />

150 Q2150BH 22<br />

175 Q2175BHn 22<br />

200 Q2200BH 22<br />

225 Q2225BHn 22<br />

100 HQ2100H 100<br />

125 HQ2125H 100<br />

125<br />

150<br />

175<br />

Obsolete<br />

200<br />

225<br />

100<br />

125<br />

150<br />

175<br />

Obsolete<br />

200<br />

225<br />

UL Interrupting<br />

Breaker Ratings (kA)<br />

Volts AC 120/240<br />

MBK<br />

MBK<br />

(100,125)A (150,200,225)A<br />

QPJ<br />

2-Pole QPP<br />

For inches / millimeters conversion, see Application Data section.<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

a All circuit breakers on this page are common trip.<br />

b Reverse handle.<br />

c CSA Listed.<br />

d MBK100A for use in 100 and 125A load centers.<br />

MBK125A for use in 125A load centers.<br />

MBK150A for use in 150, 200 and 225A load centers.<br />

MBK200A for use in 200 and 225A load centers.<br />

MBK225A for use in 225A load centers.<br />

MBK175A for use in 200 and 225A load centers.<br />

e QNR required for horizontal applications or vertical<br />

applications where the lugs are facing up. The QN<br />

breaker is required for vertical applications where the<br />

lugs are facing down as shown.<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-45


Circuit Breakers<br />

Line Diagrams/Dimension Drawings<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

1<br />

1-Pole 2-Pole 3-Pole<br />

3"<br />

2 3 /8"<br />

3 1 /8"<br />

QP, QPH, HQP<br />

Type QT<br />

Type QPF, QPHF, QE, QAF2, QAF2H<br />

Type EQ8681, EQ8682<br />

Type EQ8693, EQ8695, EQ8696<br />

Type QPJ<br />

Type QN, QNH, HQN<br />

Type QNR, QNRH, HQNR<br />

Type QPP, QPPH, HQPP, HQPPH<br />

a All standard circuit breakers are calibrated to 40°C maximum<br />

ambient application.<br />

1-46<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Circuit Breakers<br />

Revised on 03/31/20<br />

Lug Data<br />

Circuit Breaker Type<br />

Circuit Breaker<br />

Ampere Rating<br />

LOAD SIDE<br />

Cables<br />

Per Connector<br />

Connector<br />

Wire Range<br />

QP, QPH, HQP, Plug-in 10 1 or 2 #14-#16 AWG Cu<br />

15–35<br />

40–50<br />

55-125<br />

QP 1 & 2-Pole Only 55-60 1<br />

QT 15–35<br />

QPF, QPHF 15–30<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

40 1 #8 AWG CU-Al<br />

40–50 Exception:<br />

1 & 2-pole QP at 55-60<br />

40–60<br />

QAF2, QAFH2, QFGA2, QFGAH2 15–20<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

#14–#6 AWG Cu<br />

#14–#6 AWG Al<br />

#8–#6 AWG Cu<br />

#8–#4 AWG Al<br />

#8-#2/0 AWG Cu<br />

#8-#2/0 AWG Al<br />

#6-#4 AWG Cu-Al<br />

(#3 AWG compatible with QPH & HQP)<br />

#14–#6 AWG Cu<br />

#14–#6 AWG Al<br />

#8–#6 AWG Cu<br />

#8–#4 AWG Al<br />

#14–#10 AWG Cu<br />

#12–#8 AWG Al<br />

#8–#6 AWG Cu<br />

#8–#4 AWG Al<br />

#14–#12 AWG Cu<br />

#12–#10 AWG Al<br />

QD 15–20 2 #14–#10 AWG Cu Only<br />

1<br />

#14–#12 AWG Cu<br />

15–20<br />

1<br />

#12–#10 AWG Al<br />

25–35<br />

40–60<br />

1<br />

1<br />

1<br />

1<br />

#10–#8 AWG Cu<br />

#10–#6 AWG Al<br />

#8–#6 AWG Cu<br />

#8–#4 AWG Al<br />

QN, QNH, HQN 150–200 1 #1–300kcmil Cu-Al<br />

QS, QSH, QSHH, HQS, HQSH 100–225 1 #3–300kcmil Cu-Al<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

EQ8681-Ultimate, PL, ES, PN, SN 100 1 #4–3/0 AWG Cu-Al<br />

EQ8682-Ultimate, PL, ES, PN, SN 125 1 #4–3/0 AWG Cu-Al<br />

EQ8693-Ultimate, PL, ES, PN, SN 150 1 #1–300kcmil Cu-Al<br />

EQ8695-Ultimate, PL, ES, PN, SN 200 1 #1–300kcmil Cu-Al<br />

EQ8696-Ultimate, PL, ES, PN, SN 225 1 #1–300kcmil Cu-Al<br />

QPP, QPPH, HQPP, HQPPH 125<br />

150<br />

175<br />

200<br />

225<br />

EQ9675-EQIII 100<br />

EQ9677-EQIII 125<br />

EQ9683-EQIII 150<br />

EQ9684 175<br />

EQ9685-EQIII 200<br />

EQ9686-EQIII 225<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

#1 AWG Cu<br />

#2/0 AWG Al<br />

#1/0 AWG Cu<br />

#3/0 AWG Al<br />

#2/0 AWG Cu<br />

#4/0 AWG Al<br />

#3/0 AWG Cu<br />

250kcmil AWG Al<br />

#4/0 AWG Cu<br />

300kcmil AWG Al<br />

#8-#2/0 AWG Cu<br />

#8-#2/0 AWG Al<br />

#8-#2/0 AWG Cu<br />

#8-#2/0 AWG Al<br />

#1/0 AWG Cu<br />

#3/0 AWG Al<br />

#3/0 AWG Cu<br />

250kcmil AWG Al<br />

#2/0 AWG Cu<br />

#4/0 AWG Al<br />

#4/0 AWG Cu<br />

300kcmil AWG Al<br />

QPJ 125–200 1 #2–300kcmil Cu-Al<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-47


Circuit Breakers<br />

Circuit Breaker Accessories<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Circuit Breaker Accessories <br />

Catalog Number For Use With Breaker Type Number of Poles Standard Package<br />

Padlocking Device<br />

For locking breaker in “OFF” position. Note “ON” position does not affect breaker fuctionally<br />

ECPLD1 Type QP, BL, QAF2, QPF2, QE, QT-Duplex, BQ, BQXD 1P 3 Pieces<br />

ECPLD1R<br />

Type QP, BL, QAF2, QPF, QE, QT-Duplex, BQ, BQXD 1P<br />

3 Pieces<br />

(Red Color)<br />

ECPLD2<br />

Type QP, BL, QAF2, QPF, QE, QT-Triplex & Quadplex, BQ, 2P<br />

3 Pieces<br />

BQXD<br />

ECPLD2R<br />

Type QP, BL, QAF2, QPF, QE, QT-Triplex & Quadplex, BQ, 2P<br />

3 Pieces<br />

BQXD (Red Color)<br />

ECPLD3 Type QP, BL, QAF2, QPF, QE, BQ 3P 1 Piece<br />

US2:ECPLD3R Type QP, BL, QAF2, QPF, QE, BQ (Red Color) 3P 1 Piece<br />

ECQLD3 Type QP, BL, BQ, BQXD 1P 10 Pieces<br />

ECQLD4 Type QT-Duplex QT-Duplex Breakers 10 Pieces<br />

ECQLN3 150-225 MBKA, QN, QNR n/a 1 Piece<br />

ECQTH4 Type QP, BL, BQH Designed for (3) 1P Breakers 1 Piece<br />

Handle Tie<br />

Provide simultaneous swiching of 2 adjacent handles.<br />

ECQTH2 Type QT Duplex Designed for (2) QT Duplex Breakers 25 Pieces<br />

ECQTH3 Type QP, BL 2P 50 Pieces<br />

Mechanical Interlock <br />

ECQML12 Type QP, BL, BQ Interlock Bracket Designed for 1” Breaker 10 Pieces<br />

Handle Blocking Device<br />

For holding breaker in “ON” or “OFF” position. Not a lockout/tagout device<br />

ECQL1 Type QP, BL, BQ, BQXD 1P 10 Pieces<br />

ECBX231M Type QT-Duplex 1/2” Breakers 10 Pieces<br />

Main Breaker Retainer<br />

ECMBR1 EQ Load Centers 1 Piece<br />

ECMBR2 PL, ES, and Ultimate Load Centers: 2-pole QP 1 Piece<br />

ECMBR3 PL, ES, and Ultimate Load Centers: 3-pole QP 1 Piece<br />

Mounting Accessories<br />

MB120 Type BQ, BQH Mounting Clips 1P 20 Pieces<br />

FP9508 Type BQ, BQH FACE MOUNT PLATE 1P 10 Pieces<br />

FP9555 Type BQ, BQH FACE MOUNT PLATE 2P 10 Pieces<br />

FP9556 Type BQ, BQH FACE MOUNT PLATE 3P 10 Pieces<br />

SMB6R Type BQ MOUNTING BRACKET 1P, 2P, 3P 6 Pieces<br />

TCH65K Type BQ MOUNTING ADAPTER 500 Pieces<br />

BR2 Type BQ, BQH, BQXD Back Mounting Plates 2P 10 Pieces<br />

BR3 Type BQ, BQH, BQXD Back Mounting Plates 3P 10 Pieces<br />

BR4 Type BQ, BQH, BQXD Back Mounting Plates 4P 10 Pieces<br />

I0204ML1125CU Type QP Back Mounting Plates 1P, 2P 10 Pieces<br />

I0303ML3100CU Type QP Back Mounting Plates 3P 10 Pieces<br />

Replacement Lugs<br />

TA1Q1 Type BQ, NGG 100A Al Cu LGS n/a 6 Pieces<br />

TC1Q1 Type BQ, NGG 40A Al Cu LUGS n/a 6 Pieces<br />

Finger Shield<br />

BQFS1K Type BQXD Finger Shield (Bulk Pack) n/a 1000 Pieces<br />

BQFS2 Type BQXD Finger Shield n/a 2 Pieces<br />

Filler Plate<br />

ECQF3 1” Filler Plate n/a 5 Pieces<br />

For a complete list of standby power mechanical<br />

interlock kits, see page 1-25<br />

For use with Ultimate Load Center Main Breakers<br />

Not suitable for use on 15-50A, 10 AIC Type QP Circuit<br />

Breakers<br />

QP Type includes QPH, HQP<br />

BL Type includes BLH, HBL<br />

BQ Type includes BQH, HBQ<br />

QAF2 Type includes QAFH2, BAF2, BAFH2, QFGA2,<br />

QFGAH2, BFGA2, BFGAH2<br />

QPF Type includes QPHF, BLF, BLHF<br />

QE Type includes QEH, BLE, BLEH<br />

1-48<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Circuit Breakers<br />

Circuit Breaker Accessories<br />

Padlocking Device<br />

ECPLD1<br />

ECQLD3<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

ECPLD2<br />

ECPLD1R/2R/3R (Single pole<br />

pictured. 2-/3-pole available) ECQLD4 ECQTH4<br />

Handle Tie<br />

Handle Blocking Device<br />

ECQL1<br />

ECQTH2<br />

ECQTH3<br />

ECBX231M<br />

Main Breaker Retainer<br />

Mechanical Interlock<br />

ECMBR1<br />

ECMBR2<br />

ECQML12<br />

Mounting Accessories<br />

FP9508<br />

FP9556<br />

MB120<br />

SMB6R<br />

I0204ML1125<br />

FP9555<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-49


Surge Protection<br />

Circuit Breaker and Surge Protective Device (SPD)<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Features<br />

n 2 inch wide plug-on design<br />

— Includes (2) 1 Pole circuits breakers<br />

— No loss of load center spaces<br />

n Easy to install and perfect for retrofit<br />

n LEDs provide protection status<br />

Circuit Breaker and<br />

Surge Protective Device (SPD)<br />

Benefits<br />

By installing a Siemens Circuit Breaker and Surge Protective Device (SPD) in the<br />

load center of the residence, surge protection is provided for all branch circuits .<br />

Two green LED indicator lights are provided to show that surge protection is<br />

provided for all circuits connected to the load center. These breakers should be<br />

used for circuit protection of frequently used household or facility circuits because<br />

the lights and devices connected to these circuits provide an effective indication<br />

that surge protection is being provided.<br />

The circuit breaker and SPD utilize Siemens-built 150V AC, 40mm, metal oxide<br />

varistors (MOVs). The maximum impulse rating for the SPD module is 40kA. The<br />

standard interrupting rating for the circuit breakers is 10k AIC. All Type QP circuit<br />

breakers and SPD are plug-on style, with load terminals provided. The devices<br />

are rated for 120/240V AC and are calibrated for 40 degrees C maximum ambient<br />

applications.<br />

Breaker Type Ampere Rating Catalog Number Surge Type<br />

QP<br />

1- Pole<br />

120/240V AC<br />

10K AIC<br />

(2) 15<br />

(2) 20<br />

QSA1515SPD<br />

QSA2020SPD<br />

SPD<br />

SPD<br />

Catalog Number<br />

Amperage<br />

Number of Poles<br />

Initial Clamping Level<br />

Transient Energy Rating<br />

Transient Suppression<br />

Voltage Rating<br />

Peak Current Rating (impulse)<br />

Discharge Voltage Characteristic<br />

Discharge Current Withstand Rating<br />

Circuit Breaker Interrupting Rating<br />

Listings/Certifications<br />

QSA1515SPD<br />

QSA2020SPD<br />

15 or 20 Amp<br />

(2) 1-Pole Circuit Breakers<br />

240 Volts<br />

360 Joules line-to-neutral<br />

720 Joules line-to-line<br />

500 volts peak, line-to-neutral<br />

1000 volts peak, line-to-line<br />

40,000 amperes<br />

@ 1,500A, 600 volts<br />

@ 5,000A, 800 volts<br />

(both line-to-neutral)<br />

10,000 amperes<br />

line-to-neutral<br />

10,000A, 120/240V AC<br />

UL, CSA<br />

Meets UL 1449 4th Edition<br />

For warranty information please refer to the surge<br />

website www.usa.siemens.com/surge<br />

1-50<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


s<br />

1-888-333-3545<br />

usa.siemens. com/surge<br />

s<br />

Surge Protection<br />

Power Service Entrance Surge Protection<br />

FirstSurge TM<br />

- Power, Plus, or Pro<br />

n 4th Listed, Type 2, Surge Protective Device (SPD<br />

n Surge Current Capacities:<br />

– 60,000 A,FirstSurge Power (FS060)<br />

– 100,000 A,FirstSurge Plus (FS100)<br />

– 140,000 A, FirstSurge Pro (FS140)<br />

n 3 Stage Commercial Grade Notification:<br />

– Protection Status LEDs<br />

– Audible Alarm<br />

– Flashing Red Service LED<br />

n Ground Reference Monitoring (GRM)<br />

n 10 year product & connected equipment warranty*<br />

* See www.usa.siemens.com/surge for warranty terms and conditions.<br />

FirstSurge – FS060, FS100, FS140<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

Surge Type<br />

FirstSurge Power<br />

FirstSurge Plus<br />

FirstSurge Pro<br />

Catalog Number<br />

FS060<br />

FS100<br />

FS140<br />

A<br />

C<br />

To Protected Loads<br />

AC Surge Protection<br />

UL and CSA Listings 1449 4th Edition & CSA 22.2 No. 269.2<br />

Surge Spike Capacity<br />

60kA, 100kA, or 140kA<br />

Line Voltage<br />

120/240 1 Phase 50/60 Hz<br />

UL 1449 4th Edition VPR<br />

L-N, L-G, N-G: 600 V; L-L: 900V<br />

Rated Voltage (MCOV)<br />

L-N, L-G, and N-G: 150V; L-L: 300V<br />

Short Circuit Current<br />

Rating (SCCR)<br />

100kA<br />

Inominal (I n ) Rating<br />

20kA<br />

Response Time


SPD - Surge Protective Device<br />

Telephone Service Entrance Surge Protection<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

FSPHONE & FSPHONE4X<br />

n UL/cUL listed<br />

n Hardwired Telephone/Modem/Fax/DSL protection<br />

n Exceptionally fast response time<br />

n Low insertion loss<br />

n Available with or without enclosure<br />

n 5 Year product warranty*<br />

* See www.usa.siemens.com/surge for warranty terms and conditions.<br />

The Siemens FSPHONE & FSPHONE4X is a 2 pair, hardwired<br />

surge protector designed to stop surges from entering<br />

through the main telephone incoming service connection. It<br />

is equipped with a failshort device to permanently ground the<br />

telephone line in the event of a power cross. The FSPHONE<br />

is designed for indoor applications where the FSPHONE4X is<br />

useed for outdoor mounting is required.<br />

The FSPHONE4X includes the FSPHONE plus a weatherproof<br />

enclosure to facilitate indoor or outdoor applications. The<br />

enclosure is molded of temperature and humidity resistant<br />

thermoplas-tic to resist cracking and discoloration. The cover<br />

FSPHONE<br />

AC Surge Protection<br />

Catastrophic Surge Circuit<br />

Yes<br />

Spike Capacity<br />

200 Amps<br />

Let Through Voltage


AC Disconnects<br />

1-Phase, NEMA 3R Rated<br />

1<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

WN2060 WN2060GFCI WF2060PL<br />

WNAS2060GFCI<br />

Steel AC Disconnects a<br />

Ampere Disconnect Horse Power Dimensions Pallet<br />

Rating Type Catalog Number Rating Height Width Depth Qty.<br />

30 Fused Pullout WF2030 3 7 1 ⁄4 5 2 1 ⁄8 360<br />

60 Fused Pullout WF2060 10 9 5 2 1 ⁄8 360<br />

60 Non-fused Pullout WN2060 10 7 1 ⁄4 5 2 1 ⁄8 360<br />

60 Non-automatic Switch WNAS2060 10 7 1 ⁄4 5 2 1 ⁄8 360<br />

Plastic AC Disconnects a<br />

Ampere Disconnect Horse Power Dimensions Pallet<br />

Rating Type Catalog Number Rating Height Width Depth Qty.<br />

30 Fused Pullout WF2030PL 3 7 1 ⁄4 5 2 1 ⁄2 216<br />

60 Fused Pullout WF2060PL 10 7 1 ⁄4 5 2 1 ⁄2 216<br />

60 Non-fused Pullout WN2060PL 10 7 1 ⁄4 5 2 1 ⁄2 360<br />

60 Non-Fused Pullout WN2060PLX 10 8 5 3 ⁄4 3 1 ⁄2 288<br />

60 Non-automatic switch WNAS2060PL 10 7 1 ⁄4 5 2 1 ⁄2 360<br />

Steel AC Disconnects with 15 Amp GFCI Receptacle a<br />

Ampere Disconnect Horse Power Dimensions Pallet<br />

Rating Type Catalog Number Rating Height Width Depth Qty.<br />

30 Fused Pullout WF2030GFCI 3 9 6 1 ⁄8 5 3 ⁄16 112<br />

60 Fused Pullout WF2060GFCI 10 9 6 1 ⁄8 5 3 ⁄16 112<br />

60 Non-fused Pullout WN2060GFCI 10 7 1 ⁄8 5 3 ⁄4 5 3 ⁄16 144<br />

60 Non-automatic Switch WNAS2060GFCI 10 7 1 ⁄8 5 3 ⁄4 5 3 ⁄16 144<br />

Wire Range Table<br />

Copper<br />

Aluminum<br />

Connector Solid Stranded Solid Stranded<br />

Line #14-8 #14-3 #12-8 #12-3<br />

Load #14-8 #14-3 #12-8 #12-3<br />

Neutral #12-8 #12-2 #12-8 #12-2<br />

Equip. Grnd #12-8 #12-2 #12-8 #12-2<br />

a Accepts Class H Fuse<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 1-53


Load Centers and Circuit Breakers<br />

Notes<br />

LOAD CENTERS &<br />

CIRCUIT BREAKERS<br />

1<br />

1-54<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Meter Centers<br />

SPEEDFAX TM<br />

2Section<br />

Single Position Meter Socket<br />

c o n t e n t s<br />

Talon Single and Multiple Meter Sockets<br />

General Information 2-2 – 2-4<br />

Single Position Meter Sockets - Residential Types 2-5 – 2-6<br />

Multiple Position Meter Sockets — Residential Types 2-7 – 2-8<br />

Single Position Meter Sockets — Commercial Types 2-9 – 2-10<br />

Special Application Meter Sockets 2-11<br />

Pedestal and Breaker Combination Meter Mounting Equipment 2-12<br />

Temporary Power Outlets 2-13 – 2-21<br />

Transformer-Rated Meter Mounting Equipment 2-22 – 2-24<br />

Accessories 2-25<br />

Knockout Diagrams 2-26 – 2-33<br />

2 METER<br />

CENTERS<br />

Meter Centers / Combination Meter Sockets<br />

Catalog Number Logic and Introduction 2-34 – 2-35<br />

Surface Mount Meter-Mains 2-36 – 2-37<br />

Surface Mount Meter-Load Center Combo 2-38 – 2-41<br />

EUSERC Meter-Main Breaker 2-42<br />

SOLAR Ready, Surface/Flush Mount,<br />

Meter-Load Center Combination 2-43 – 2-45<br />

EUSERC Side-by-Side Meter Load Center Combo 2-46 – 2-47<br />

EUSERC Over/Under Meter Load Center Combo 2-48<br />

EUSERC Commercial Metering 2-49 – 2-50<br />

Accessories and Knockout Diagrams 2-51 – 2-67<br />

Over-Under Meter<br />

Load Center Combinations<br />

Murray Combination Meter Sockets<br />

Catalog Numbering Logic and Introduction 2-69 – 2-70<br />

100A-400A Meter Mains 2-71<br />

150A-200A Over-Under Construction 2-72<br />

100A-400A Meter Load Centers 2-73<br />

125A-400A EUSERC Side-By-Side Construction 2-74<br />

100A-225A EUSERC Meter Load Center 2-75<br />

400A EUSERC Side-By-Side Construction 2-76<br />

Group Metering: NYC Gangable Metering 2-78 – 2-82<br />

Side-by-Side Meter<br />

Load Center Combination<br />

Scan to connect<br />

online to the<br />

most up-todate<br />

version of<br />

this Section of<br />

SPEEDFAX.<br />

(Section was last modified on 03/18/19)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-1


Meter Centers<br />

Meter Mounting Devices<br />

Introduction<br />

Meter Socket<br />

METER<br />

CENTERS<br />

2<br />

Talon has been the standard for quality<br />

and innovation for meter mounting<br />

equipment for over half a Century, only<br />

under different brand names. The heart<br />

of our offering continues to be the HQ<br />

lever bypass socket. The basic design<br />

of this socket has not changed since its<br />

original inception in 1956 making this a<br />

solid, time-proven design. We continue<br />

to offer the HQ at a competitive price<br />

even when faced with lower cost and<br />

lower quality competition. The bypass<br />

blade for every HQ is rated for 320<br />

amps making every one of our sockets<br />

“Heavy Duty”.<br />

Our K base products continue to<br />

offer the same dependability and cost<br />

advantages for “extended range”<br />

metering. The residential socket<br />

line continues to grow daily as we<br />

continuously add or update our products<br />

for an ever-changing market.<br />

All Siemens single family sockets are<br />

branded as “Talon,” a name with much<br />

history behind it. The same great quality<br />

products you expect from Siemens, only<br />

with a different logo<br />

This publication is meant to serve only as a guide to our various meter socket product families, while providing a<br />

representation of each product family we have to offer. This catalog only contains a very small percentage of our<br />

total offering, and keep in mind that all meter sockets must be approved by your local utility before being installed.<br />

Please consult your regional Talon catalog that lists a more tailored offering for your area, along with utility<br />

approvals; these catalogs can be found at www.talonmetering.com. Please consult with your utility about the<br />

approvals prior to buying and installing a socket.<br />

2-2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Meter Centers<br />

Meter Mounting Devices<br />

Introduction<br />

General Information<br />

Materials:<br />

16 gauge, galvanized steel, G-90<br />

Enclosures:<br />

NEMA 3R<br />

Finish:<br />

Steel - Light gray, baked on powder<br />

polyester<br />

Latches:<br />

All swing latches are stainless steel<br />

Block Material:<br />

Glass reinforced polyester<br />

Terminals:<br />

Residential - Tin-plated aluminum<br />

extrusions 6061-T6<br />

Commercial - Tin-plated copper and<br />

or tin plated aluminum<br />

Accessories:<br />

All hubs, closure plates, and 5th<br />

terminals, if included, are factory<br />

installed.<br />

Standards:<br />

Products cataloged herein meet or<br />

exceed the following standards:<br />

UL 486B, UL 414, NEMA 250,<br />

ANSI C12.7 UL File #30413<br />

2 METER<br />

CENTERS<br />

Siemens/Talon meter socket designs<br />

have been in the industry for more than<br />

60 years. No one knows metering<br />

installations like Siemens. Our meter<br />

sockets set the standard for quality,<br />

design, & workmanship. This is why we<br />

use stainless steel hardware; polyester<br />

powder-coat paint for long-lasting<br />

protection and appearance; type G90<br />

galvanized steel or 3003 grade aluminum<br />

enclosures and, in our commercial<br />

sockets, an all-plated copper current<br />

path. This is why Siemens meter sockets<br />

are seen in so many utility specifications.<br />

Features:<br />

n Residential single position sockets<br />

(types UAT) feature a quad neutral as a<br />

standard feature.<br />

n Most commercial sockets include<br />

a ground lug & some models are<br />

available with line & load lugs installed.<br />

n Lever bypass sockets feature the type<br />

HQ socket which is recognized by<br />

utilities as the industry standard for<br />

durability & quality.<br />

n Siemens features one of the most<br />

complete and comprehensive Meter<br />

socket lines available from any<br />

manufacturer.<br />

Meter Socket<br />

UAS877-PPZA<br />

4-Jaw 1Ø 3W 200 Amp Residential Horn<br />

Bypass - Sidewire Design<br />

40407-02CO<br />

7-Jaw 3Ø 4W 200 Amp Lever<br />

Bypass Type “HQ”<br />

48707-82GP<br />

7-Jaw 3Ø 4W 320 Amp Lever Bypass<br />

Type HQ - Sidewire Design<br />

UAT417-XG<br />

4-Jaw 1Ø 3W 200 Amp Residential -<br />

No Bypass<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-3


Meter Centers<br />

Meter Socket Bypass Types<br />

2<br />

METER<br />

CENTERS<br />

There are several different bypass types used in the meter socket industry. The<br />

type of bypass used is dependent upon each individual utilities’ requirements for<br />

that application. The illustrations and photos below will explain some of the basic<br />

bypass types seen in section 2 of the Siemens’ <strong>Speedfax</strong>. This page is meant<br />

for informative purposes only and is not meant to imply or convey the use of any<br />

particular bypass or inter-changing of any types of bypass for any application. The<br />

local utility should always be contacted to ensure approval of equipment prior to<br />

installation. The types of bypasses listed below are for utility use only.<br />

Meter Socket<br />

Horn Bypass:<br />

Small tabs or “horns” on the line and load side of the meter socket act as electrical<br />

connection points for the utility to install a bypassing means- usually a specially<br />

produced wire or “jumper” designed for this specific application.<br />

Lever Bypass:<br />

A lever is used to rotate a plated copper blade between the line and load jaws. The<br />

lever bypass HQ socket also clamps on the meter when the bypass is dis-engaged.<br />

The bypass must be engaged to remove the meter then dis-engaged after the<br />

meter is installed. The bypass acts as an alternate path for current flow which helps<br />

to mitigate any arcing if the meter is being removed. This also ensures a constant<br />

current flow should the meter need to be removed.<br />

Test Block Bypass:<br />

Test Block Bypass sockets (TBB) have the line and load connectors mounted parallel<br />

to one another. This provides for a provision to bypass the meter by placing a<br />

jumper on the line and load bus. Note that this type of bypass is used primarily by<br />

those utilities subscribing to the EUSERC metering standards.<br />

2-4<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Meter Centers<br />

Single Position Meter Sockets—Residential Types <br />

2 METER<br />

CENTERS<br />

UAT111-0PGP<br />

UAT111-0GF<br />

UAT111-0MXA<br />

135 Amp Continuous Meter Mounting Equipment, Ringless, 1-Phase, 3-Wire 600V 1 Position<br />

Catalog<br />

Dimensions (inches) Cont.<br />

Number H W D Amps Service Lugs<br />

HORN BYPASS<br />

No. of<br />

Jaws<br />

5th<br />

Jaw<br />

Hub<br />

Provision<br />

KO<br />

Fig.<br />

Meter Socket<br />

UAT111-0PGP <br />

UAT111-0PQG<br />

11.7 8.0 3.7 135 OH/UG #14-2/0 4<br />

UAT111-0PDN <br />

UAT111-0PZA <br />

UAT111-0PV<br />

EC659-0121<br />

Installed<br />

RX Opening<br />

NO BYPASS<br />

UAT111-0G<br />

UAT111-0GF <br />

4 EC659-0121<br />

OH/UG<br />

UAT111-0JCA<br />

11.7 8.0 3.7 135<br />

#14-2/0<br />

RX Opening 1A<br />

UAT111-0MXA 5 Installed<br />

UAT111-PG UG 4 EC659-0121 None 1B<br />

1A<br />

135 Amp Continuous Meter Mounting Equipment, Ring Type, 1-Phase, 3-Wire 600V 1 Position<br />

Catalog<br />

Dimensions (inches) Cont.<br />

Number H W D Amps Service Lugs<br />

No. of<br />

Jaws<br />

5th<br />

Jaw<br />

Hub<br />

Provision<br />

KO<br />

Fig.<br />

NO BYPASS<br />

UAT121-0BCO 5 Installed<br />

OH/UG<br />

UAT121-0GWR 4 EC659-0121<br />

UAT121-BBCO <br />

5 Installed<br />

UAT121-BGWR 11.7 8.0 3.7 135 OH #14-2/0 4 EC659-0121<br />

UAT121-BM 5 Installed<br />

UAT121-PBCO <br />

5 Installed<br />

UG<br />

UAT121-PGWR 4 EC659-0121<br />

RX Opening<br />

EC38597 Inst.<br />

None<br />

1A<br />

1B<br />

Contact utility or sales office for approval<br />

by your local utility prior to installation.<br />

7/16” Barrel lock knockout<br />

7/8” Barrel lock knockout<br />

Stainless Steel latch and hasp<br />

Labeled for use on Duquense Light Company<br />

Sealing ring included<br />

All devices include a quad ground<br />

Add prefix "S" to catalog number for retail or single<br />

packed version<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-5


Meter Centers<br />

Single Position Meter Sockets—Residential Types d <br />

METER<br />

CENTERS<br />

2<br />

UAT417-XGF<br />

UAT317-0PGP<br />

UAS877-PPZA<br />

Meter Socket<br />

200 Amp Continuous/250 Amp Max Meter Mounting Equipment, Ringless,<br />

1-Phase, 3-Wire 600V 1 Position<br />

Catalog<br />

Dimensions (inches) Cont.<br />

Number H W D Amps Service Lugs<br />

No. of<br />

Jaws<br />

5th<br />

Jaw<br />

Hub<br />

Provision<br />

HORN BYPASS<br />

UAT317-0FP 5 Installed<br />

UAT317-0PDN<br />

UAT317-0PGP <br />

14.8 8.0 4.5 200 OH #6-350<br />

RX Opening 2<br />

4<br />

UAT317-0PQG<br />

UAT317-0PZA <br />

UAT417-0PQG<br />

4 EC659-0121 RX Opening<br />

UAT417-XFP 5 Installed RX CL. Plate<br />

14.8 11.4 4.5 200 OH/UG #6-350<br />

3A<br />

UAT417-XPCV 4 EC659-0121 RX CL. Plate<br />

UAT417-XPQG<br />

UAS817-PPGP 8<br />

UAS877-PPCV <br />

UAS877-PPDN <br />

14.0 13.0 5.2 200 UG-SW #6-350 4 EC659-0121 None<br />

UAS877-PPGP <br />

6A<br />

UAS877-PPZ<br />

UAS877-PPZA <br />

NO BYPASS<br />

UAT317-0G<br />

4 EC659-0121<br />

UAT317-0GF 4 EC659-0121 RX Opening<br />

14.8 8.0 4.5 200 OH #6-350<br />

UAT317-0MXA 5 Installed<br />

2<br />

UAT317-DGZ 4 EC659-0121 EC38599 Inst.<br />

UAT417-PG<br />

UG #6-350 4 EC659-0121 None 3B<br />

UAT417-XG<br />

14.8 11.4 4.5 200<br />

UAT417-XGDU<br />

OH/UG #6-350 4 EC659-0121 RX CL. Plate 3A<br />

UAT417-XGF <br />

UAT517-PDG 18.0 13.0 5.2<br />

UG<br />

None<br />

3B<br />

UAT618-XGNM 22.0 11.4 4.5 OH/UG RX CL. Plate 3A<br />

UAS818-PGNM 200<br />

#6-350 4 EC659-0121<br />

8<br />

14.0 13.0 5.2 UG-SW None<br />

UAS877-PG<br />

6A<br />

UAS917-XJCA 17.0 13.0 5.2 OH/UG-SW RX CL. Plate 7<br />

200 Amp Continuous/250 Amp Max Meter Mounting Equipment, Ring Type,<br />

1-Phase, 3-Wire 600V 1 Position<br />

Catalog<br />

Dimensions (inches) Cont.<br />

Number H W D Amps Service Lugs<br />

No. of<br />

Jaws<br />

5th<br />

Jaw<br />

Hub<br />

Provision<br />

KO<br />

Fig.<br />

KO<br />

Fig.<br />

NO BYPASS<br />

UAT327-0GWR 4 EC659-0121<br />

14.8 8.0 4.5 200 OH #6-350<br />

UAT327-0MCO 5 Installed<br />

RX Opening 2<br />

UAT427-PMCO UG<br />

5 Installed None 3B<br />

14.8 11.4 4.5 200<br />

#6-350<br />

UAT427-XMWR OH/UG 4 EC659-0121 RX CL. Plate 3A<br />

Contact utility or sales office for approval<br />

by your local utility prior to installation.<br />

7/16” Barrel lock knockout<br />

7/8” Barrel lock knockout<br />

Stainless Steel latch and hasp<br />

All devices include a ground lug<br />

Labeled for use on Delmarva Power and Atlantic City Electric<br />

Sealing ring included<br />

Labeled for use on Duquense Light Company<br />

Line side studs<br />

Add prefix "S" to catalog number for retail or single<br />

packed version<br />

2-6<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Meter Centers<br />

Single & Multiple Position Meter Sockets—Residential Types<br />

UA2311-0PGP with<br />

EC659-0121 installed<br />

WSC250C<br />

UA2717-YPGP<br />

2 METER<br />

CENTERS<br />

100 Amp/Position Meter Mounting Equipment, Ringless, 1-Phase, 3-Wire 300V Multi-Position <br />

Catalog<br />

Number <br />

HORN BYPASS<br />

Dimensions (inches)<br />

H W D<br />

Bus<br />

Amps<br />

Cont.<br />

Amps<br />

Service<br />

No. of<br />

Pos.<br />

No. of<br />

Jaws<br />

5th<br />

Jaw<br />

Hub<br />

Provision<br />

UA2311-0PGP <br />

UA2311-0PQG 12.4 24.0 4.5 100 100 OH/UG 2 4 EC659-0121 RX Opening<br />

UA3311-0PGP <br />

UA3311-0PQG 12.4 32.0 4.5 135 100 OH/UG 3 4 EC659-0121 RX Opening<br />

UA4311-0PGP <br />

UA4311-0PQG 12.4 40.0 4.5 180 100 OH/UG 4 4 EC659-0121 RX Opening<br />

200 Amp/Position Meter Mounting Equipment, Ringless, 1-Phase, 3-Wire 300V Multi-Position <br />

KO<br />

Fig.<br />

16A<br />

16B<br />

17A<br />

17B<br />

18A<br />

18B<br />

Line<br />

Lugs<br />

Load<br />

Lugs<br />

#6-350 KCMIL #14-2/0<br />

#6-350 KCMIL #14-2/0<br />

#6-350 KCMIL #14-2/0<br />

UA2717-YPDN <br />

HORN BYPASS<br />

4 EC659-0121 HD Opening<br />

UA2717-YPGP 5 Installed HD CL. Plate<br />

13.9 24.0 5.2 200 200 OH/UG 2<br />

UA2717-YPQG 4 EC659-0121 HD Opening<br />

19A #1/0-600 KCMIL<br />

UA2717-YPZA 4 EC659-0121 HD Opening<br />

UA3717-YPDN 4 EC659-0121 HD Opening<br />

UA3717-YPGP 13.9 32.0 5.2 270 200 OH/UG 3 5 Installed HD CL. Plate 20A #1/0-600 KCMIL<br />

UA3717-YPZA 4 EC659-0121 HD Opening<br />

UA4719-YPDN 4 EC659-0121 HD Opening<br />

UA4719-YPGP 5 Installed HD CL. Plate<br />

(2)#1/0-600<br />

13.9 43.4 5.2 360 200 OH/UG 4<br />

21A<br />

UA4719-YPQG 4 EC659-0121 HD Opening<br />

KCMIL<br />

UA4719-YPZA 4 EC659-0121 HD Opening<br />

UA5719-KPGP 2-HD Opening (2)#1/0-600<br />

13.9 51.4 5.2 450 200 OH/UG 5 4 EC659-0121<br />

22<br />

UA5719-KPDN <br />

2-HD Opening KCMIL<br />

UA6719-KPQG 2-HD Opening (2)#1/0-600<br />

13.9 59.4 5.2 528 200 OH/UG 6 4 EC659-0121<br />

23<br />

UA6719-KPZA <br />

2-HD Opening KCMIL<br />

100/80 Amp/Position Meter Mounting Equipment, Ring Type, 1-Phase, 3-Wire 300V Multi-Position<br />

Catalog<br />

Dimensions (inches)<br />

Number<br />

H W D<br />

NO BYPASS<br />

WSC150C 15.3<br />

11.3<br />

Bus<br />

Amps<br />

Cont.<br />

Amps<br />

Service<br />

No. of<br />

Pos.<br />

No. of<br />

Jaws<br />

5th<br />

Jaw<br />

Hub<br />

Provision<br />

1<br />

24<br />

1.25" KO<br />

WSC250C 30.5 3.8 — 80 OH/UG 2 5 Installed<br />

25<br />

in Top<br />

WSC350C 45.5 3 26<br />

WSN251CR 19.6<br />

2<br />

30<br />

WSN351CR 15.5 29.6 4.1 200 100 OH/UG 3 5 Installed RX CL. Plate 31<br />

WSN451CR 39.6 4 32<br />

KO<br />

Fig.<br />

Line<br />

Lugs<br />

#6-350<br />

KCMIL<br />

#6-350<br />

KCMIL<br />

#6-350<br />

KCMIL<br />

#6-350<br />

KCMIL<br />

#6-350<br />

KCMIL<br />

Load<br />

Lugs<br />

#6-4/0 #8-2/0<br />

#6-250 KCMIL #8-2/0<br />

Meter Socket<br />

Contact utility or sales office for approval<br />

by your local utility prior to installation.<br />

7/16” Barrel lock knockout<br />

7/8” Barrel lock knockout<br />

Stainless Steel latch and hasp<br />

Ground lug included<br />

2 Ground lugs included<br />

Sealing ring included<br />

Unit is unbussed and indoor<br />

Center feed<br />

End feed<br />

Labeled for use on Duquense Light Company<br />

Add prefix "S" to catalog number for retail or single<br />

packed version<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-7


Meter Centers<br />

Murray Branded Multiple Position Ring Type<br />

METER<br />

CENTERS<br />

2<br />

SC250C<br />

SN251CR<br />

SS251CR<br />

Meter Socket<br />

80 Amp/Position Meter Mounting Equipment<br />

1 Phase, 3 Wire, 300V Multi-Position Residential End Feed<br />

Catalog<br />

Dimensions (inches)<br />

Number<br />

H W D<br />

SC150C a 15.3<br />

11.3<br />

Bus<br />

Amps<br />

Cont.<br />

Amps<br />

Service<br />

No. of<br />

Pos.<br />

1<br />

SC250C a 30.5 3.9 n/a 80 OH/UG 2 5 Installed 1.25” KO Top #6-4/0 #8-2/0 25<br />

SC350C a 45.6 3 26<br />

100 Amp/Position Meter Mounting Equipment<br />

1 Phase, 3 Wire, 300V Multi-Position Residential End Feed<br />

Catalog<br />

Number<br />

NO BYPASS<br />

SN211AR<br />

Dimensions (inches)<br />

H W D<br />

Bus<br />

Amps<br />

Cont.<br />

Amps<br />

Service<br />

No. of<br />

Pos.<br />

27.6<br />

2<br />

27<br />

SN311AR 14.1 35.8 5.3 200 100 OH/UG 3 4 EC659-0121 RX Opening #6-250 #8-2/0 28<br />

SN411AR 44.0 4 29<br />

SN251CR<br />

19.6<br />

2<br />

30<br />

SN351CR 15.5 29.6 4.1 200 100 OH 3 5 Installed RX CL. Plate #6-250 #8-2/0 31<br />

SN451CR 39.6 4 32<br />

100 Amp/Position Meter Mounting Equipment<br />

1 Phase, 3 Wire, 300V Multi-Position Vertical Mounting<br />

Catalog<br />

Number<br />

Dimensions (inches)<br />

H W D<br />

Bus<br />

Amps<br />

Cont.<br />

Amps<br />

Service<br />

No. of<br />

Pos.<br />

NO BYPASS<br />

SN205CX 25.6 8.0 4.4 200 100 OH 2 5 Installed RX Opening #8-350 #8-2/0 44<br />

SN305CX 35.9 8.0 4.4 200 100 OH 3 5 Installed RX Opening #8-350 #8-2/0 45<br />

200 Amp/Position Meter Mounting Equipment<br />

1 Phase, 3 Wire, 300V Multi-Position Residential Center Feed<br />

Catalog<br />

Dimensions (inches) Bus Cont.<br />

No. of No. of 5th<br />

Line Load KO<br />

Number<br />

H W D Amps Amps Service Pos. Jaws Jaw Hub<br />

Lugs Lugs Fig.<br />

SS251CR<br />

28.0<br />

200<br />

2<br />

19B<br />

#8-250<br />

SS351CR 14.1 38.0 5.4 270 200 OH/UG 3 5 Installed HD Opening #1/0-500<br />

20B<br />

KCMIL<br />

SS451CR 48.0 360 4 21B<br />

No. of<br />

Jaws<br />

No. of<br />

Jaws<br />

No. of<br />

Jaws<br />

5th<br />

Jaw<br />

5th<br />

Jaw<br />

5th<br />

Jaw<br />

Hub<br />

Hub<br />

Hub<br />

Line<br />

Lugs<br />

Line<br />

Lugs<br />

Line<br />

Lugs<br />

Load<br />

Lugs<br />

Load<br />

Lugs<br />

Load<br />

Lugs<br />

KO<br />

Fig.<br />

24<br />

KO<br />

Fig.<br />

KO<br />

Fig.<br />

Contact utility or sales office for approval<br />

by your local utility prior to installation.<br />

aUnit is unbussed, indoor, and gangable.<br />

2-8<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Meter Centers<br />

Single Position Meter Sockets—Commercial/Industrial Types <br />

2 METER<br />

CENTERS<br />

40405-02CO 40407-02CO 9804-9142<br />

200 Amp Continuous Meter Mounting Equipment, Ringless, Lever Bypass, 1-Phase, 3-Wire 600V<br />

Catalog<br />

Dimensions (inches) Cont.<br />

Number H W D Amps Service Lugs<br />

4 OR 5 TERMINAL<br />

No. of<br />

Jaws<br />

Hub<br />

Provision<br />

KO<br />

Fig.<br />

4 RX CL. PLATE 9A<br />

Meter Socket<br />

5 RX CL. PLATE 9A<br />

40405-015F <br />

40405-025 <br />

19.0 12.8 5.0 200 OH/UG #6-350 KCMIL<br />

40404-02QG <br />

40405-02QG <br />

40405-02CO <br />

40405-02GP <br />

40405-0BNU 19.0 12.8 5.0 200 OH/UG #6-350 KCMIL 5 RX OPENING 9A<br />

42505-02RG 3/8-24 STUD<br />

RX CL. PLATE 9A<br />

19.0 12.8 5.0 200 OH/UG<br />

5<br />

44305-02CV #6-350 KCMIL HD CL. PLATE 9B<br />

48805-0BNU 22.0 16.0 5.0 200 OH/UG #6-350 KCMIL 5 RX CL. PLATE 6B<br />

200 Amp Continuous Meter Mounting Equipment, Ringless, Lever Bypass, 3-Phase, 4-Wire 600V<br />

Catalog<br />

Dimensions (inches) Cont.<br />

Number H W D Amps Service Lugs<br />

No. of<br />

Jaws<br />

Hub<br />

Provision<br />

7 TERMINAL<br />

40007-01GP 17.5 10.0 5.0 200 OH #6-350 KCMIL 7 RX OPENING 10<br />

40407-02QG <br />

40407-025<br />

40407-015F <br />

19.0 12.8 5.0 200 OH/UG #6-350 KCMIL 7 RX CL. PLATE 9A<br />

40407-02CO <br />

40407-02GP <br />

40407-01NU RX OPENING 9A<br />

19.0 12.8 5.0 200 OH/UG #6-350 KCMIL 7<br />

44307-02CV HD CL. PLATE 9B<br />

48807-02NU 22.0 16.0<br />

OH/UG<br />

6B<br />

5.0 200<br />

#6-350 KCMIL 7 RX CL. PLATE<br />

9804-9142 20.0 16.1 UG-SW 33<br />

KO<br />

Fig.<br />

Contact utility or sales office for approval<br />

by your local utility prior to installation.<br />

7/16” Barrel lock knockout<br />

7/8” Barrel lock knockout<br />

Stainless Steel latch and hasp<br />

Ground lug included<br />

2 Ground lugs included<br />

5th jaw installed at 6:00 position<br />

5th jaw installed at 9:00 position<br />

Labeled for use on Delmarva Power and Atlantic City Electric<br />

Murray brand labeled device<br />

Clamp jaw lever bypass type HQ<br />

Add prefix "S" to catalog number for retail or single<br />

packed version<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-9


Meter Centers<br />

Single Position Meter Sockets—Commercial/Industrial Types<br />

<br />

METER<br />

CENTERS<br />

2<br />

47704-02<br />

48104-02 9817-8061<br />

Meter Socket<br />

320 Amp Continuous/400 Amp Max Meter Mounting Equipment, Ringless, Lever Bypass,<br />

1-Phase, 3-Wire 600V <br />

Catalog<br />

Dimensions (inches) Cont.<br />

No. of Hub<br />

KO<br />

Number H W D Amps Service Lugs<br />

Jaws Provision<br />

Fig.<br />

4 OR 5 TERMINAL<br />

44704-8265 34.0 20.2 6.2 320<br />

OH/<br />

UG-SW<br />

#4-600 4 HD CL. PLATE 11A<br />

47604-81GP #4-600 4 HD OPENING<br />

28.0 12.8 5.0 320 OH/UG<br />

47605-02SP 3/8-24 STUD 5 HD CL. PLATE<br />

12<br />

47704-01NU 4 HD OPENING<br />

47704-02 28.0 13.8 6.0 320 OH/UG 1/2-20 STUD 4 HD CL. PLATE 13<br />

47705-01NU 5 HD OPENING<br />

48104-02 OH/ 3/8-24 STUD 4<br />

31.0 16.2 5.0 320<br />

48105-83BU UG-SW #4-600 5<br />

HD CL. PLATE 14<br />

48504-92 28.0 12.8 5.0<br />

UG 3/8-24 STUD<br />

NONE 35<br />

48704-82GP 34.0 20.2 6.2<br />

320 OH/<br />

4<br />

#4-600<br />

UG-SW<br />

HD CL. PLATE 11B<br />

9804-9144 25.0 16.0 6.0<br />

13<br />

320 OH/UG 3/8-24 STUD 4 HD OPENING<br />

9804-9146 34.0 20.2 6.2 11C<br />

320 Amp Continuous/400 Amp Max Meter Mounting Equipment, Ringless, Lever Bypass,<br />

3-Phase, 4-Wire 600V <br />

Catalog<br />

Dimensions (inches) Cont.<br />

Number H W D Amps Service Lugs<br />

No. of<br />

Jaws<br />

Hub<br />

Provision<br />

7 TERMINAL<br />

47707-01NU 1/2-20 STUD<br />

HD OPENING<br />

28.0 13.8 6.0 320 OH/UG<br />

7<br />

13<br />

47707-02 3/8-24 STUD HD CL. PLATE<br />

48707-82GP OH/<br />

34.0 20.2 6.2 320<br />

#4-600 7 HD CL. PLATE 11B<br />

UG-SW<br />

9804-9145 25.0 16.0 6.0<br />

HD OPENING 13<br />

320 OH/UG 3/8-24 STUD 7<br />

9804-9147 34.0 20.2 6.2 HD CL. PLATE 11C<br />

400 Amp Continuous/400-480 Amp Max Meter Mounting Equipment, K7 Bolt-in, No Bypass,<br />

3-Phase, 4-Wire 600V<br />

Catalog<br />

Dimensions (inches) Cont.<br />

Number H W D Amps Service Lugs<br />

No. of<br />

Jaws<br />

Hub<br />

Provision<br />

7 TERMINAL<br />

9817-8061 34.0 20.0 6.2 400 UG<br />

HD CL. PLATE 15<br />

1/2-20 Stud 7<br />

9817-9504 43.1 20.0 6.2 480 OH/UG (2) HD CL. Plate 15<br />

KO<br />

Fig.<br />

KO<br />

Fig.<br />

Contact utility or sales office for approval<br />

by your local utility prior to installation.<br />

7/16” Barrel lock knockout<br />

7/8” Barrel lock knockout<br />

Stainless Steel latch and hasp<br />

Ground lug included<br />

Bolt-in meter socket<br />

Lugs not included, order separately<br />

Anti-inversion clip included<br />

5th Jaw installed at 9:00<br />

Add prefix "S" to catalog number for retail or single<br />

packed version<br />

2-10<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Meter Centers<br />

Special Application Meter Sockets<br />

<br />

MS44UTB<br />

MS14TB<br />

100-320 Amp Continuous EUSERC-Approved Meter Mounting Equipment,<br />

Ring Type, Test Block Bypass, 1-Phase & 3-Phase<br />

Catalog<br />

Number<br />

MS14TB<br />

Dimensions<br />

(inches)<br />

Cont.<br />

H W D Amps Service Lugs<br />

No.<br />

of<br />

Jaws<br />

5th<br />

Jaw<br />

1-Ph/3-Wire #6-2/0 4 EC5J<br />

MS15TB 24.1 12.4 4.8 100 3-Ph/3-Wire #6-2/0 5 Installed<br />

MS17TB 3-Ph/4-Wire #6-2/0 7 —<br />

MS24TB<br />

1-Ph/3-Wire #1/0-250 lay-in 4 UX005B<br />

MS25TB 30.1 14.1 6.1 200 3-Ph/3-Wire #1/0-250 lay-in 5 Installed<br />

MS27TB 3-Ph/4-Wire #1/0-250 lay-in 7 —<br />

MS44UTB 34.5 15.4 6.3 320 1-Ph/3-Wire<br />

(2)#1/0-250<br />

or (1)#4-600<br />

Hub<br />

Provision<br />

KO<br />

Fig.<br />

RX 39<br />

(2x) RX-top<br />

(1x) HD-bot.<br />

(2x) RX-top<br />

(3x) HC-bot.<br />

(2x) RX-top<br />

(1x) HD-bot.<br />

40<br />

41<br />

40<br />

4 — — 44<br />

2 METER<br />

CENTERS<br />

200 Amp Mobile Home Meter Pedestal<br />

Pad or Earth Mount, Ring or Ringless Design, 4 Jaw for 1 Phase 240V AC<br />

Continuous Duty<br />

Amps Per Position Catalog Number Cover Type<br />

Line Connectors<br />

(installed)<br />

Dimensions<br />

H W D<br />

200 MP0406B1200R Ringless (2) #6-350 kcmil 55.00 10.00 4.00<br />

MP0606L1200R Ringless (2) #6-350 kcmil 55.00 10.00 4.00<br />

MP0606L1200 Ring (2) #6-350 kcmil 55.00 10.00 4.00<br />

200 Amp Mobile Home Lever Bypass Meter Pedestal<br />

Pad or Earth Mount, Ringless, 5 Jaw for 1 Phase, 240V AC<br />

200 MP0406B1200RJL Ringless (2) #6-350 kcmil 55.00 10.00 4.00<br />

200 MP0606L1200RJL Ringless (2) #6-350 kcmil 55.00 10.00 4.00<br />

Meter Socket<br />

Breakers: Units will accept up to (3) 2 pole<br />

breakers or (6) 1 pole breakers - Siemens type<br />

QP or Murray type MP for up to 125amps and<br />

Siemens type QN for 200amp.<br />

Filler Plates: Un-used openings that have had<br />

the factory twist-outs removed can use part the<br />

ECQF3 filler plate.<br />

Required Accessories:<br />

Direct Burial Kit: Use catalog number MPEXT.<br />

This lengthens the device to 84", 90", or 96"<br />

depending on adjustment of the stabilizer foot.<br />

Pad Mount Kit: Use catalog number MPFLANGE.<br />

This kit bolts to the bottom of the MPEXT and<br />

will add 11" in length.<br />

MP0606: accomodates (3) 2 pole breakers or (6)<br />

1 pole breakers types Siemens QP/Murray MP-T<br />

(125amp max) and types Siemens QN/Murray<br />

MPD (150-200amp)<br />

MP0406: Siemens type QN 200amp breaker<br />

factory installed. Additional space for 4 one<br />

pole or 2 two pole breakers types Siemens QP/<br />

Murray MP-T. Branch circuits run in parallel to<br />

200amp main breaker<br />

12 1/8”<br />

10”<br />

55”<br />

35”<br />

15”<br />

MP0606L1200R<br />

(Front)<br />

MP0606L1200RJL<br />

(Reverse)<br />

MP0606L1200RJL<br />

(Front)<br />

Contact utility or sales office for approval by your local utility prior to installation.<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-11


Meter Centers<br />

Pedestal and Breaker Combination Meter Mounting Equipment<br />

<br />

2<br />

200/320A 4-7 Terminal Pedestal<br />

And Breaker Combination Meter<br />

Mounting Equipment<br />

METER<br />

CENTERS<br />

Meter Socket<br />

Common Features<br />

n 200A and 320A continuous duty models available<br />

n Factory installed lugs or studs<br />

n Ground lug on all devices<br />

n Horn or lever bypass (uses HQ lever bypass)<br />

n Extension kits available for pedestals<br />

n Breaker devices with provisions or installed<br />

breaker<br />

n Pole mount units with breakers available<br />

n Direct burial or pad mount capability<br />

Pedestal<br />

Cont.<br />

Amps<br />

Pos.<br />

No.<br />

of<br />

Term. Svc.<br />

Terminal Connector<br />

Dimensions<br />

(inches)<br />

47604-9CH<br />

Line Load Bypass W H D<br />

Hub<br />

Opening<br />

5th Jaw<br />

Kit No.<br />

UAB317-0PCH<br />

Breaker<br />

Breaker<br />

Type<br />

UAPB317-PPCH<br />

Catalog<br />

Number<br />

200 4 UG #6-350 kcmil #6-350 kcmil Horn 8.0 64.5 4.5 Blank Top H659-0121 None N/A UAP317-PPWI b<br />

200 4 UG 4/0-comp. lug See Breaker Horn 8.0 64.5 4.5 Blank Top H659-0121 200A-prov. QPP UAPB317-PPWI b<br />

200 5 UG #6-350 kcmil #6-350 kcmil Lever 11.0 56.0 6.0 Blank Top N/A None N/A 40405P-9WI b<br />

200 7 UG #6-350 kcmil #6-350 kcmil Lever 11.0 56.0 6.0 Blank Top N/A None N/A 40407P-9CH b<br />

200 7 UG #6-350 kcmil #6-350 kcmil Lever 11.0 56.0 6.0 Blank Top N/A None N/A 40407P-9UE b<br />

200 7 UG (2) #4-350 kcmil (2) #4-350 kcmil Lever 11.0 56.0 6.0 Blank Top N/A None N/A 40407P-9WI b<br />

320 4 UG 3/8”-24 Stud (2) #4-350 kcmil Lever 13.0 56.0 5.0 Blank Top H35815-2 None N/A 47604P-9CH b<br />

320 4 UG 1/0-600 kcmil #6-350 kcmil Lever 13.0 56.0 5.0 Blank Top H35815-2 None N/A 47604P-9WI b<br />

320 4 UG 3/8”-24 Stud #6-350 kcmil Lever 13.0 56.0 5.0 Blank Top H35815-2 (2) 200A-inst. QJ 47604PB-9CH b<br />

Combo<br />

Cont.<br />

Amps<br />

Pos.<br />

No.<br />

of<br />

Term. Svc.<br />

Dimensions<br />

Terminal Connector<br />

(inches)<br />

Line Load Bypass W H D<br />

Hub<br />

Opening<br />

5th Jaw<br />

Kit No.<br />

Breaker<br />

Breaker<br />

Type<br />

Catalog<br />

Number<br />

200 4 OH #14-2/0 See Breaker Horn 8.0 28.5 4.5 RX Opening H659-0121 125A-prov. QP UAB111-0PCH b<br />

200 4 OH #6-350 kcmil #6-300 kcmil Horn 8.0 28.5 4.5 RX Opening H659-0121 200A-inst. QJ UAB317-0PCH <br />

200 4 OH/UG (2) 1/0-600 kcmil #6-350 kcmil None 11.3 28.5 4.3 RX Cl. Plate H659-0121 200A-inst. QJ UAB417-XG b<br />

125 5 OH/UG #6-250 kcmil #2-1/0 CU, 2/0 AL Horn 18.5 17.0 5.1 RX Cl. Plate Installed 125A inst. QN LGMM0202B1125RJBX b<br />

150 5 OH/UG #6-250 kcmil #1-300 KCMIL Horn 18.5 17.0 5.1 RX Cl. Plate Installed 150A inst. QN LGMM0202B1150RJBX b<br />

200 5 OH/UG #6-250 kcmil #1-300 KCMIL Horn 18.5 17.0 5.1 RX Cl. Plate Installed 200A inst. QN LGMM0202B1200RJBX b<br />

125 4 OH/UG #14-2/0 See Breaker None 10.9 20.8 4.4 RX Cl. Plate H659-0121 QP UAB111-XG b<br />

100 4 OH/UG #14-2/0 See Breaker None 10.9 20.8 4.4 RX Cl. Plate H659-0121 QP UAB111-100 b<br />

125 4 OH/UG #14-2/0 See Breaker None 10.9 20.8 4.4 RX Cl. Plate H659-0121 QP UAB111-125 b<br />

200 4 OH/UG #6-350 kcmil See Breaker None 11.6 27.8 5.2 RX Cl. Plate H659-0121 QN/QP UAB417-XPG b<br />

150 4 OH/UG #6-350 kcmil See Breaker None 11.6 27.8 5.2 RX Cl. Plate H659-0121 QN UAB417-150 b<br />

200 4 OH/UG #6-350 kcmil See Breaker None 11.6 27.8 5.2 RX Cl. Plate H659-0121 QN UAB417-200 b<br />

200 4 UG #6-350 kcmil See Breaker None 13.2 25.2 5.2 Blank Top H659-0121 QN UAB877-PG b<br />

200 4 UG #6-350 kcmil See Breaker None 13.2 25.2 5.2 Blank Top H659-0121 QN UAB877-200 b<br />

Ring style cover.<br />

b Ringless style cover.<br />

Contact utility or sales office for approval<br />

by your local utility prior to installation.<br />

2-12<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Temporary Power Outlet Panels<br />

Power Outlet Panel Types Available<br />

2 METER<br />

CENTERS<br />

Earth Mount Pedestals<br />

n Unmetered<br />

n Ring Type (Metered)<br />

n Ringless Type (Metered)<br />

n Lighted with photocell option<br />

Meter Socket<br />

Surface<br />

n Unmetered<br />

n Ring Type Metered<br />

(Meter at top or bottom)<br />

n Ringless Metered<br />

(Meter at top or bottom)<br />

n Lighted<br />

Pad Mount Pedestals<br />

n Unmetered<br />

n Ring Type (Metered)<br />

n Ringless Type (Metered)<br />

n Lighted with photocell option<br />

Additional Accessories<br />

n Cable television & Phone connection<br />

n Water Connection<br />

Back to Back<br />

Earth Mount Pedestals<br />

n Unmetered<br />

n Ring Type (Metered)<br />

n Ringless Type (Metered)<br />

n Lighted with photocell option<br />

Back to Back<br />

Pad Mount Pedestals<br />

n Unmetered<br />

n Ring Type (Metered)<br />

n Ringless Type (Metered)<br />

n Lighted with photocell option<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-13


Temporary Power Outlet Panels<br />

Product Features<br />

Enclosures<br />

Pedestals<br />

Interiors (continued)<br />

2<br />

METER<br />

CENTERS<br />

Meter Socket<br />

A Rainproof<br />

Rainproof NEMA Type 3R construction.<br />

B Quality Finish<br />

All sheet metal components are<br />

powder coated with the highest<br />

quality finish and fabricated with G90<br />

galvanized steel.<br />

C Installation Ease<br />

Three raised mounting embosses<br />

make installation a snap.<br />

D Removable Deadfronts<br />

Easily removable upper and lower<br />

deadfronts allow easy access to<br />

internal components for ease of<br />

installation.<br />

E Theft Resistant<br />

The padlock provisions and elevated<br />

upper deadfront design prevent<br />

unauthorized removal of the plugs or<br />

access to the circuit breakers.<br />

F Meters Top or Bottom<br />

Metered units are available with<br />

meters at the top or bottom.<br />

b Ring and ringless type meter<br />

covers available.<br />

b Utility grade, meter socket base.<br />

b Units with meter at bottom are<br />

ideally suited for underground<br />

feeds.<br />

b Meter sockets available to 125<br />

amps maximum.<br />

G Easy Access Door<br />

Door allows additional room for plugs<br />

and is designed to open & close easily<br />

H Overhead/Underground Feeds<br />

Surface devices have provisions for<br />

overhead and underground feeds.<br />

b For an overhead feed, use a<br />

readily available Type RX<br />

interchangeable hub. Closure<br />

plate is factory included.<br />

b For an underground feed, an<br />

extensive variety of easily<br />

removable knockouts are<br />

provided.<br />

J One-Piece Construction<br />

Rigid, one-piece pedestal<br />

construction for all earth and pad<br />

mounted devices. Thoroughly tested<br />

for torsion and flexing resistance.<br />

K Block Assembly<br />

Loop-feed block assembly provides<br />

connectors capable of accepting up to<br />

350 kcmil conductors.<br />

(Standard option on pedestal devices.<br />

Available option on un-metered devices.)<br />

L Pad Mount<br />

Pad mounted devices are available.<br />

(not shown)<br />

Interiors<br />

M Bus Bars<br />

Plated bus bars provide the best<br />

protection against corrosion.<br />

N Copper Conductors<br />

Ready to use! All internal components<br />

are factory prewired with copper<br />

conductors.<br />

O Circuit Protection<br />

All receptacles are protected by<br />

lifetime warranted Siemens circuit<br />

breakers.<br />

P Receptacles<br />

Impact-resistant, thermoplastic,<br />

commercial grade receptacles.<br />

Q GFCI Protection<br />

All 125 volt, 20amp receptacles offer<br />

a GFCI protection option. Weather<br />

resistant receptacles are also available.<br />

Siemens GFCI circuit breakers are<br />

available to provide protection for all<br />

receptacles.<br />

<br />

<br />

R Wire Connectors<br />

All wire connectors are suitable for<br />

use with copper or aluminum wire.<br />

(not shown)<br />

<br />

<br />

<br />

A<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

I Light Option<br />

Lighted option to assist with<br />

nighttime site location and operation.<br />

Light provisions are the longest<br />

lasting and have the lowest<br />

operating cost in the industry. Light can<br />

be wired in conjunction with a 120V<br />

photocell to minimize energy use.<br />

<br />

<br />

<br />

<br />

<br />

<br />

2-14<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Temporary Power Outlet Panels<br />

Revised on 03/31/19<br />

Build Your Own Catalog Numbering System<br />

<br />

<br />

<br />

<br />

T –<br />

<br />

<br />

<br />

<br />

Talon<br />

Temporary<br />

Power<br />

Main Type<br />

Main Lugs,<br />

L 125A<br />

Main Breaker,<br />

D 100A<br />

a Required fields.<br />

b A minimum of 1 receptacle<br />

must be selected. A maximum<br />

of 3 receptacles, with<br />

up to 125amps total, may be<br />

selected. UL does not allow<br />

field installation of receptacle<br />

kits.<br />

c Two receptacle devices ship<br />

in a 7" wide enclosure and<br />

are wired with a 3 circuit<br />

interior. Depending on the<br />

receptacle configuration<br />

selected an additional circuit<br />

may or may not be available<br />

d Enclosure includes same<br />

loop feed lugs as the pedestal<br />

devices. Enclosure is<br />

larger. Please see knockout<br />

diagrams for details.<br />

e Dash is only present if one<br />

of the options listed after<br />

the dash is needed.<br />

f Light kits are installed by<br />

the factory and require<br />

either a 120V GFCI breaker<br />

or 5-20RGFI receptacle to<br />

power the light fixture.<br />

Cable TV, phone, & water<br />

accessories are purchased<br />

separately and are not configured<br />

as part of the device.<br />

Photocell is factory wired and<br />

is mounted internally. 120V<br />

AC photocell only.<br />

"X" designates alternate<br />

receptacle configuration on<br />

each side. Contact sales<br />

office for pricing.<br />

Receptacles (3 max)<br />

1 14-50R 125/250V 50A<br />

1F<br />

Designates GFCI Circuit Breaker<br />

Protection<br />

2 14-30R 125/250V 30A<br />

2F<br />

Designates GFCI Circuit Breaker<br />

Protection<br />

3 TT30R 125V 30A<br />

3F<br />

Designates GFCI Circuit Breaker<br />

Protection<br />

4 L6-30R 250V 30A<br />

4F<br />

Designates GFCI Circuit Breaker<br />

Protection<br />

5 6-20R 250V 20A<br />

5F<br />

Designates GFCI Circuit Breaker<br />

Protection<br />

6 L5-20R 125V 20A<br />

6F<br />

8G<br />

Designates GFCI Circuit Breaker<br />

Protection<br />

7 5-20R2GFI 125V 20A<br />

5-20R2 125V 20A<br />

Designates weather resistant<br />

receptacle with GFCI Circuit<br />

Breaker Protection<br />

9 L-530R 125V 30A<br />

9F<br />

Designates GFCI Circuit Breaker<br />

Protection<br />

Meter/Bypass<br />

U<br />

R<br />

N<br />

L<br />

H<br />

Unmetered<br />

Ringless,<br />

No Bypass<br />

Ring, No Bypass<br />

Ringless,<br />

Lever Bypass<br />

Ringless,<br />

Horn Bypass<br />

Enclosure Type<br />

S<br />

Surface<br />

mount,<br />

un-metered<br />

Surface<br />

S2 mount,<br />

un-metered,<br />

loop feed lugs<br />

T<br />

surface<br />

mount, top<br />

feed-metered<br />

surface<br />

mount,<br />

B bottom feedmetered<br />

Direct burial<br />

P pedestal<br />

Pad mount<br />

M pedestal<br />

Direct burial<br />

2P pedestal,<br />

double-sided<br />

Pad mount<br />

2M pedestal,<br />

double sided<br />

RC<br />

MEG<br />

Approved<br />

Surface Mount<br />

Custom Options<br />

L Light kit factory<br />

installed<br />

Light kit with<br />

LP photocell<br />

factory installed<br />

Alternate<br />

receptacle<br />

X configuration<br />

on double-sided<br />

pedestal<br />

Custom color<br />

Cx configuration<br />

Custom Color<br />

Guidelines:<br />

b "Cx" designates custom<br />

color. Contact<br />

sales office for<br />

color code to insert<br />

into part number to<br />

replace the "x" in this<br />

designation.<br />

b Additional charges<br />

apply and depend on<br />

the color needed.<br />

b Custom color<br />

matching available:<br />

Customer must<br />

signoff on painted<br />

sample prior to production<br />

of order.<br />

b Order cancellations<br />

will involve a fee<br />

after custom paint is<br />

ordered.<br />

2 METER<br />

CENTERS<br />

Meter Socket<br />

Example: Catalog Number: TL1F37NT-LP<br />

Given specifications:<br />

b 125A Main Lugs<br />

b 50A, 125/250V receptacle with<br />

GFCI circuit breaker<br />

b 30A, 125V receptacle with a<br />

standard circuit breaker<br />

b 20A, 125V GFCI weather<br />

resistant receptacle<br />

b Ring type meter at the top<br />

b Surface mount device<br />

b Light option with photocell<br />

Step 1<br />

Start with the power receptacle product line prefix identifier: (T)<br />

Step 2<br />

Choose main type: (L)<br />

Step 3<br />

Choose the first receptacle and its circuit breaker type: (1F)<br />

Step 4<br />

Choose the second receptacle and its circuit breaker type: (3)<br />

Step 5<br />

Choose the third receptacle and its circuit breaker type: (7)<br />

Step 6<br />

Choose utility meter & bypass type required: (N)<br />

Step 7<br />

Choose enclosure type: (T)<br />

Step 8<br />

Add dash and select light option with photocell: (-LP)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-15


Temporary Power Outlet Panels<br />

2<br />

METER<br />

CENTERS<br />

Meter Socket<br />

Most Common Items—See Previous Page to Build Your Own Catalog Number<br />

Catalog Number Mains Type Enclosure Type Meter Provision Receptacle #1 Receptacle #2 Receptacle #3 Options<br />

Surface Mount, Un-Metered<br />

TL17US 125A Main Lug Surface Mount Un-Metered 14-50R 5-20R2 GFI W.R. N/A N/A<br />

TL37US 125A Main Lug Surface Mount Un-Metered TT30R 5-20R2 GFI W.R. N/A N/A<br />

TL77US 125A Main Lug Surface Mount Un-Metered 5-20RGFI W.R. 5-20R2 GFI W.R. N/A N/A<br />

TL137US 125A Main Lug Surface Mount Un-Metered 14-50R TT30R 5-20R2 GFI W.R. N/A<br />

TL577US 125A Main Lug Surface Mount Un-Metered 6-20R 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A<br />

TL1F7US 125A Main Lug Surface Mount Un-Metered 14-50R, GFCI Brkr 5-20R2 GFI W.R. N/A N/A<br />

TL1F3F7US 125A Main Lug Surface Mount Un-Metered 14-50R, GFCI Brkr TT30R, GFCI Brkr 5-20R2 GFI W.R. N/A<br />

TL5F8G8GUS 125A Main Lug Surface Mount Un-Metered 6-20R, GFCI Brkr<br />

5-20R2, GFCI Brkr,<br />

W.R.<br />

5-20R2, GFCI Brkr,<br />

W.R.<br />

TL1F3F7US2 125A Main Lug Surface Mount Un-Metered 14-50R, GFCI Brkr TT30R, GFCI Brkr 5-20R2 GFI W.R.<br />

Surface Mount, Metered<br />

TL137UP 125A Main Lug Burial Pedestal Un-Metered 14-50R TT30R 5-20R2 GFI W.R. N/A<br />

TL137NP 125A Main Lug Burial Pedestal Un-Metered 14-50R TT30R 5-20R2 GFI W.R. N/A<br />

N/A<br />

Loop Feed<br />

Lugs<br />

TL1F3F7UP 125A Main Lug Burial Pedestal Un-Metered 14-50R, GFCI Brkr TT30R, GFCI Brkr 5-20R2 GFI W.R. N/A<br />

TL138GUP 125A Main Lug Burial Pedestal Un-Metered 14-50R TT30R<br />

5-20R2, GFCI Brkr,<br />

W.R.<br />

N/A<br />

TL137UP-LP 125A Main Lug Burial Pedestal Un-Metered 14-50R TT30R 5-20R2 GFI W.R.<br />

Light &<br />

Photocell<br />

TL137U2P 125A Main Lug<br />

Burial Pedestal-<br />

Double Sided<br />

Un-Metered 14-50R TT30R 5-20R2 GFI W.R. N/A<br />

Pedestal Mount, Metered & Un-Metered<br />

TL77NT 125A Main Lug Top Feed Metered- Ring 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A N/A<br />

TL77NB 125A Main Lug Bottom Feed Metered- Ring 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A N/A<br />

TL77RT 125A Main Lug Top Feed Metered- Ringless 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A N/A<br />

TL77RB 125A Main Lug Bottom Feed Metered- Ringless 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A N/A<br />

TL137RT 125A Main Lug Top Feed Metered- Ringless 14-50R TT30R 5-20R2 GFI W.R. N/A<br />

TL577NT 125A Main Lug Top Feed Metered- Ring 6-20R 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A<br />

TL1F77NT 125A Main Lug Top Feed Metered- Ring 14-50R, GFCI Brkr 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A<br />

TL1F77RB 125A Main Lug Bottom Feed Metered- Ringless 14-50R, GFCI Brkr 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A<br />

TL5F77NT 125A Main Lug Top Feed Metered- Ring 6-20R, GFCI Brkr 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A<br />

TL5F77RT 125A Main Lug Top Feed Metered- Ringless 6-20R, GFCI Brkr 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A<br />

TL5F77RB 125A Main Lug Bottom Feed Metered- Ringless 6-20R, GFCI Brkr 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A<br />

Special Accessories<br />

Catalog Number Description Notes<br />

TLAWATER Water Connection Accessory Accessories are intended to mount on each side of a direct burial or pad mount pedestal.<br />

These accessories can be used independently provided they are mounted on a<br />

TLATVP<br />

Television & Phone Connection Accessory flat surface. Mounting these accessories to round poles is not recommended.<br />

2-16<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Temporary Power Outlet Panels<br />

Dimension Drawings<br />

2 METER<br />

CENTERS<br />

Meter Socket<br />

Unmetered Surface Mount, 7"wide<br />

Enclosure size for un-metered devices<br />

with two receptacles only.<br />

Unmetered Surface Mount, 10" wide<br />

Unmetered Surface Mount, 10"wide<br />

with Loop Feed Lugs<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-17


Temporary Power Outlet Panels<br />

Dimension Drawings<br />

Meter Socket<br />

METER<br />

CENTERS<br />

2<br />

Metered Top Feed Surface Mount<br />

Metered Bottom Feed Surface Mount<br />

2-18<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Temporary Power Outlet Panels<br />

Dimension Drawings<br />

2 METER<br />

CENTERS<br />

Meter Socket<br />

Metered Pedestal Direct Burial<br />

Unmetered Pedestal Direct Burial<br />

Metered Pedestal Direct Burial<br />

Back to Back<br />

Unmetered Pedestal Direct Burial<br />

Back to Back<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-19


Temporary Power Outlet Panels<br />

Dimension Drawings<br />

Meter Socket<br />

METER<br />

CENTERS<br />

2<br />

Metered Pedestal Pad Mount<br />

Unmetered Pedestal Pad Mount<br />

Metered Pedestal Pad Mount<br />

Back to Back<br />

Unmetered Pedestal Pad Mount<br />

Back to Back<br />

2-20<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Temporary Power Outlet Panels<br />

Dimension Drawings<br />

2 METER<br />

CENTERS<br />

Pad Mount Bolt Pattern<br />

Meter Socket<br />

Catalog Number: TLAWATER<br />

Water Kit<br />

Catalog Number: TLATVP<br />

Television & Phone Combination<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-21


Meter Centers<br />

Transformer-Rated Meter Mounting Equipment<br />

<br />

2<br />

METER<br />

CENTERS<br />

Meter Socket<br />

Type PTS Transformer-Rated<br />

Meter Mounting Equipment<br />

with Test Switch Provisions<br />

Common Features<br />

n 20A continuous rated<br />

n Ground lug available<br />

n Steel or aluminum construction<br />

n Split or solid cover construction<br />

n OH and UG capabilities<br />

n 600V rated<br />

n Spacing for multiple test switch configurations<br />

n Customized test switch and wiring<br />

Consult the factory for other available options such as, but not<br />

limited to alternate enclosure and hasp material, kearnaloxed<br />

terminals, enclosures with special KO configurations, pre-wired<br />

units, test switch specifications and special labeling.<br />

KNOCKOUTS (inches):<br />

B: 1/2, 3/4<br />

Q: 1, 1-1/4, 1-1/2<br />

AC: 1/4, 1/2<br />

RX: Ø2.750 HUB 0P<br />

Socket<br />

Type<br />

PTS6:<br />

6 Jaw<br />

PTS8:<br />

8 Jaw<br />

PTS13:<br />

13 Jaw<br />

Catalog Numbers<br />

Cont.<br />

Terminal<br />

Ringless - Solid Cover Ringless - Split Cover Ring Type - Split Cover Dimensions (in.) Amp Hub<br />

Wire Range<br />

Aluminum Steel Aluminum Steel Aluminum Steel L W D Rating Opening Current Potential<br />

9837-8200 9837-8201 9837-8202 9837-8203 9837-8204 9837-8205 20.0 12.0 4.5 20 RX Cl. Plate #4-14 #8-14<br />

9837-8210 9837-8211 9837-8212 9837-8213 9837-8214 9837-8215 20.0 12.0 4.5 20 1” Hub Inst. #4-14 #8-14<br />

9837-8220 9837-8221 9837-8222 9837-8223 9837-8224 9837-8225 20.0 12.0 4.5 20 1.25” Hub Inst. #4-14 #8-14<br />

9837-8230 9837-8231 9837-8232 9837-8233 9837-8234 9837-8235 20.0 12.0 4.5 20 1.50” Hub Inst. #4-14 #8-14<br />

9837-8240 9837-8241 9837-8242 9837-8243 9837-8244 9837-8245 20.0 12.0 4.5 20 RX Opening #4-14 #8-14<br />

9837-8400 9837-8401 9837-8402 9837-8403 9837-8404 9837-8405 20.0 12.0 4.5 20 RX Cl. Plate #4-14 #8-14<br />

9837-8410 9837-8411 9837-8412 9837-8413 9837-8414 9837-8415 20.0 12.0 4.5 20 1” Hub Inst. #4-14 #8-14<br />

9837-8420 9837-8421 9837-8422 9837-8423 9837-8424 9837-8425 20.0 12.0 4.5 20 1.25” Hub Inst . #4-14 #8-14<br />

9837-8430 9837-8431 9837-8432 9837-8433 9837-8434 9837-8435 20.0 12.0 4.5 20 1.50” Hub Inst. #4-14 #8-14<br />

9837-8440 9837-8441 9837-8442 9837-8443 9837-8444 9837-8445 20.0 12.0 4.5 20 RX Opening #4-14 #8-14<br />

9837-8500 9837-8501 9837-8502 9837-8503 9837-8504 9837-8505 20.0 12.0 4.5 20 RX Cl. Plate #4-14 #8-14<br />

9837-8510 9837-8511 9837-8512 9837-8513 9837-8514 9837-8515 20.0 12.0 4.5 20 1” Hub Inst. #4-14 #8-14<br />

9837-8520 9837-8521 9837-8522 9837-8523 9837-8524 9837-8525 20.0 12.0 4.5 20 1.25” Hub Inst #4-14 #8-14<br />

9837-8530 9837-8531 9837-8532 9837-8533 9837-8534 9837-8535 20.0 12.0 4.5 20 1.50” Hub Inst. #4-14 #8-14<br />

9837-8540 9837-8541 9837-8542 9837-8543 9837-8544 9837-8544 20.0 12.0 4.5 20 RX Opening #4-14 #8-14<br />

GENERAL INFORMATION:<br />

Capacity: 20 amperes, 600 volts a.c.<br />

Application: Transformer-rated applications. Available with or without test switch and pre-wiring.<br />

Enclosures: 14-gauge .063 aluminum or 16-gauge galvannealed steel suitable for indoor or outdoor installation.<br />

Terminals: Set screw type.<br />

Hubs: Interchangeable 1”, 1-1/4”, 1-1/2”<br />

Finish:<br />

Aluminum unpainted unless specified. Steel enclosures have gray polyester powder coat finish.<br />

Test Switches: Standard 6 and 10 pole, 480-volt rated switches are available from stock. Special switches available upon request.<br />

Contact utility or sales office for approval<br />

by your local utility prior to installation.<br />

2-22<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Meter Centers<br />

Transformer-Rated Meter Mounting Equipment<br />

<br />

Type HQ-T Transformer-Rated<br />

Meter Mounting Equipment<br />

Common Features<br />

n Clamping jaw lever bypass<br />

n 80A continuous rated<br />

n Ground lug available<br />

n Screw type terminals with pressure plate<br />

n Steel or aluminum construction<br />

n Glass filled polyester block construction<br />

n 200% rated bypass<br />

n Overhead and underground capabilities<br />

n 600V rated<br />

Consult the factory for other available options such as, but not<br />

limited to alternate enclosure and hasp material, kearnaloxed<br />

terminals, enclosures with special KO configurations, pre-wired<br />

units, test switch specifications and special labeling.<br />

KNOCKOUTS (inches):<br />

: 1/4<br />

B: 1/2, 3/4<br />

S: 1, 1-1/4, 1-1/2, 2, 2-1/2<br />

AI: 1, 1-1/4, 1-1/2, 2, 2-1/2, 3<br />

RX: Ø2.750 HUB 0P<br />

2 METER<br />

CENTERS<br />

Meter Socket<br />

Socket<br />

Type<br />

Catalog Numbers Dimensions (inches) Cont.<br />

Ampere<br />

Removable Handle Solid Handle L W D Rating<br />

Hub<br />

Opening<br />

Terminal Wire Range<br />

Current<br />

Term<br />

HQ-6T: 6 Jaw 9804-8544 9804-8548 17.5 10.0 5.0 80 RX Cl. Plate #4-14 #8-14<br />

9804-8482 9804-8485 17.5 10.0 5.0 80 1” Hub Installed #4-14 #8-14<br />

9804-8483 9804-8486 17.5 10.0 5.0 80 1.25” Hub Installed #4-14 #8-14<br />

HQ-8T: 8 Jaw 9804-8542 9804-8546 17.5 10.0 5.0 80 RX Cl. Plate #4-14 #8-14<br />

9804-8419 9804-8456 17.5 10.0 5.0 80 1” Hub Installed #4-14 #8-14<br />

9804-8422 9804-8459 17.5 10.0 5.0 80 1.25” Hub Installed #4-14 #8-14<br />

HQ-13T: 13 Jaw 9804-8543 9804-8547 17.5 10.0 5.0 80 RX Cl. Plate #4-14 #8-14<br />

9804-8420 9804-8457 17.5 10.0 5.0 80 1” Hub Installed #4-14 #8-14<br />

9804-8423 9804-8460 17.5 10.0 5.0 80 1.25” Hub Installed #4-14 #8-14<br />

9804-8426 9804-8463 17.5 10.0 5.0 80 1.50” Hub Installed #4-14 #8-14<br />

Potential<br />

Term<br />

GENERAL INFORMATION:<br />

Capacity: 80 ampere continuous, 600 volts a.c.<br />

Application: 6 terminal, single phase 2 or 3 wire; 8 terminal 2 or 3 phase, 3 wire, HQ-13T - 3 phase, 4 wire wye or 4 wire delta. For use with transformer-rated<br />

Class 10 or 20 meters. May also be used on self-contained applications up to 80 ampere load.<br />

Enclosures: Constructed of 16 gauge galvannealed steel with polyester powder coat finish. Also available in 12 gauge aluminum upon request. All<br />

enclosures are NEMA type 3R.<br />

Block Assembly: Glass fiber reinforced polyester. High strength, arc and track resistant.<br />

Bypass:<br />

Lever-Operated Jaw Release - Moving lever up closes bypass, providing positive short circuiting of the current circuits and releases<br />

jaw pressure on the meter current terminals providing easy removal of the meter. Also available is a removable bypass handle which<br />

allows a solid cover, #37943-2 for HQ-T or #54199-2 for HQ-TS, to be placed on the box with the bypass closed when it is necessary to<br />

remove the meter for in-shop repair or testing. Bypass capacity: 80 amp continuous.<br />

Terminals: Set screw type with pressure plate. Current terminals will accommodate conductors from #4 to #14. Potential terminals will accommodate<br />

from #8 to #14.<br />

Hubs:<br />

Cover plate or single removable gasketless hubs are interchangeable.<br />

UL:<br />

All sockets shown are UL approved.<br />

Safety Shield: Track resistant polycarbonate transparent safety shield provides liberal insulation between potential jaws and terminals and protection<br />

from accidental shorts and shocks.<br />

Contact utility or sales office for approval<br />

by your local utility prior to installation.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-23


Meter Centers<br />

Current Transformer Cabinet<br />

Meter Socket<br />

METER<br />

CENTERS<br />

2<br />

Current Transformer Cabinet<br />

Amperage<br />

Rating<br />

Catalog Number<br />

Hub<br />

Provisions*<br />

Connectors<br />

4 Terminal for 1 Phase, 3 Wire 240V AC<br />

Dimension<br />

W H D<br />

Millbank<br />

Equivilant<br />

400-800 LG123636CTS2 Blank 3 Lugs per Phase 36 36 12 S-1855-0<br />

800-1200 LG124848CTS2 Blank 5 Lugs per Phase 48 48 12 S-1856-0<br />

Devices are 2 door and include stainless steel handles. All devices are NEMA type 3R rated.<br />

Lugs: #2-600 kcmil<br />

* We have many more CT cabinet options for varying utilities. Please consult your regional catalog<br />

for a complete offering.<br />

Contact utility or sales office for approval<br />

by your local utility prior to installation.<br />

2-24<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Meter Centers<br />

Meter Socket Accessories<br />

<br />

RX Hub<br />

H56732 H56476 H58852<br />

H58022<br />

ECJS<br />

S64685-1 Neutral Kit<br />

EC659-0121<br />

2 METER<br />

CENTERS<br />

S35815-2<br />

SRSTD<br />

SRSS<br />

SRSW<br />

Meter Socket<br />

5TH & 6TH Jaw Assemblies<br />

For Use With<br />

All SUAxxxx single and multiple position sockets<br />

All SUAxxxx single and multiple position sockets<br />

All Lever Bypass single position sockets S35815-2<br />

SC and SD Unbussed Multiple-5th Jaw<br />

100A Test Block bypass sockets<br />

200A Test Block bypass sockets<br />

Anti-Inversion clip for use with 320amp<br />

sockets<br />

Miscellaneous Accessories<br />

Catalog Number<br />

EC659-0121 (grounded)<br />

EC659-0120 (insulated)<br />

WSX019<br />

EC5J<br />

UX005B<br />

H59676<br />

when required<br />

Description<br />

Catalog Number<br />

Insulated Neutral Kit for “S404xx” sockets EC64685<br />

Isolated Neutral Kit for S9817-8061 S69685-1<br />

Bypass Kit for S9817-8061<br />

S69623<br />

Jumper-200 Amp Rated-use on SUAxxx ECJS<br />

sockets only (temporary use only)<br />

Plastic Meter Cover- Ring<br />

ECPP<br />

Plastic Meter Cover- Ringless<br />

Neutral Isolation kit for 200amp lever<br />

bypass sockets<br />

ECCP3<br />

64690-1<br />

Interchangeable Hubs<br />

Description<br />

Sealing Rings<br />

Description<br />

Snap-On Type, aluminum<br />

Snap-On Type, steel<br />

Screw Type, aluminum<br />

Catalog Number<br />

RX CONDUIT HUBS<br />

EC38594 0 3 ⁄4<br />

EC38596 1<br />

EC38597 1 1 ⁄4<br />

EC38598 1 1 ⁄2<br />

EC38599 2<br />

EC38600 2 1 ⁄2<br />

Closure Plate EC38595 —<br />

HD CONDUIT HUBS<br />

EC56856 3<br />

EC56857 3 1 ⁄2<br />

Adapter Plate convert<br />

HD to RX<br />

EC56858 4<br />

EC9747-1113 —<br />

Closure Plate EC56933S —<br />

Hub Size<br />

(Inches)<br />

Catalog Number<br />

SRSTD<br />

SRSS<br />

SRSW<br />

Lugs for Sockets with Stud Terminals a<br />

Catalog Number For Use With Wire Range<br />

H58852 Line side of S9817 Socket on UG Applications (1) 3/0-800 kcmil<br />

H56732 Line & Load of S477 & Load/Neutral of S9817 Sockets (2) #4-350 kcmil<br />

H56476 Line & Load of S477 & Load/Neutral of S9817 Sockets (1) 3/0-750 kcmil<br />

H58022 Any socket with 3/8” Stud Terminals (2) #6-250 kcmil<br />

H55890 Any socket with 3/8” Stud Terminals (1) #6-350 kcmil<br />

a Each lug catalog number contains one lug unless otherwise noted. Order enough lugs to cover all terminations.<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-25


Meter Centers<br />

Meter Socket Knockout Diagrams<br />

METER<br />

CENTERS<br />

Meter Socket<br />

2<br />

Figure 1A<br />

Figure 1B<br />

Figure 2<br />

Figure 3A<br />

Figure 3B<br />

Figure 4<br />

KNOCKOUTS (inches):<br />

Figure 6A<br />

Figure 6B<br />

g: 1/4<br />

A: 1/2<br />

B: 1/2, 3/4<br />

L: 1/2, 3/4, 1, 1-1/4, 1-1/2<br />

N: 3/4, 1, 1-1/4, 1-1/2, 2<br />

P: 1, 1-1/4<br />

R: 1, 1-1/4, 1-1/2, 2<br />

S: 1, 1-1/4, 1-1/2, 2, 2-1/2<br />

X: 1-1/4, 1-1/2, 2, 2-1/2<br />

Z: 1-1/2, 2, 2-1/2<br />

EE: 2, 2-1/2, 3<br />

GG: 2-1/2, 3, 3-1/2<br />

HH: 2-1/2, 3, 3-1/2, 4<br />

AB: 1/4, 1/2, 7/8<br />

AC: 1/4, 1/2<br />

AD: 1-1/4, 1-1/2, 2, 2-1/2, 3<br />

AE: 1/4, 1/2, 3/4, 1, 1-1/4<br />

AF: 1, 1-1/2, 2, 2-1/2, 3<br />

AG: 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3<br />

AH: 1/4, 1/2, 3/4<br />

AI: 1, 1-1/4, 1-1/2, 2, 2-1/2, 3<br />

HD: x4.281 HUB 0P<br />

RX: x2.750 HUB 0P<br />

2-26<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Meter Centers<br />

Meter Socket Knockout Diagrams<br />

2 METER<br />

CENTERS<br />

Figure 7<br />

Figure 8<br />

Figure 9A<br />

Meter Socket<br />

Figure 9B<br />

Figure 10<br />

Figure 11A<br />

KNOCKOUTS (inches):<br />

Figure 11B<br />

Figure 11C<br />

g: 1/4<br />

A: 1/2<br />

B: 1/2, 3/4<br />

L: 1/2, 3/4, 1, 1-1/4, 1-1/2<br />

N: 3/4, 1, 1-1/4, 1-1/2, 2<br />

P: 1, 1-1/4<br />

R: 1, 1-1/4, 1-1/2, 2<br />

S: 1, 1-1/4, 1-1/2, 2, 2-1/2<br />

X: 1-1/4, 1-1/2, 2, 2-1/2<br />

Z: 1-1/2, 2, 2-1/2<br />

EE: 2, 2-1/2, 3<br />

GG: 2-1/2, 3, 3-1/2<br />

HH: 2-1/2, 3, 3-1/2, 4<br />

AB: 1/4, 1/2, 7/8<br />

AC: 1/4, 1/2<br />

AD: 1-1/4, 1-1/2, 2, 2-1/2, 3<br />

AE: 1/4, 1/2, 3/4, 1, 1-1/4<br />

AF: 1, 1-1/2, 2, 2-1/2, 3<br />

AG: 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3<br />

AH: 1/4, 1/2, 3/4<br />

AI: 1, 1-1/4, 1-1/2, 2, 2-1/2, 3<br />

HD: x4.281 HUB 0P<br />

RX: x2.750 HUB 0P<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-27


Meter Centers<br />

Meter Socket Knockout Diagrams<br />

Meter Socket<br />

METER<br />

CENTERS<br />

2<br />

Figure 12<br />

Figure 13<br />

Figure 14<br />

Figure 15<br />

Figure 16A<br />

Figure 16B<br />

KNOCKOUTS (inches):<br />

Figure 17A<br />

Figure 17B<br />

g: 1/4<br />

A: 1/2<br />

B: 1/2, 3/4<br />

L: 1/2, 3/4, 1, 1-1/4, 1-1/2<br />

N: 3/4, 1, 1-1/4, 1-1/2, 2<br />

P: 1, 1-1/4<br />

R: 1, 1-1/4, 1-1/2, 2<br />

S: 1, 1-1/4, 1-1/2, 2, 2-1/2<br />

X: 1-1/4, 1-1/2, 2, 2-1/2<br />

Z: 1-1/2, 2, 2-1/2<br />

EE: 2, 2-1/2, 3<br />

GG: 2-1/2, 3, 3-1/2<br />

HH: 2-1/2, 3, 3-1/2, 4<br />

AB: 1/4, 1/2, 7/8<br />

AC: 1/4, 1/2<br />

AD: 1-1/4, 1-1/2, 2, 2-1/2, 3<br />

AE: 1/4, 1/2, 3/4, 1, 1-1/4<br />

AF: 1, 1-1/2, 2, 2-1/2, 3<br />

AG: 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3<br />

AH: 1/4, 1/2, 3/4<br />

AI: 1, 1-1/4, 1-1/2, 2, 2-1/2, 3<br />

HD: x4.281 HUB 0P<br />

RX: x2.750 HUB 0P<br />

2-28<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Meter Centers<br />

Meter Socket Knockout Diagrams<br />

2 METER<br />

CENTERS<br />

Figure 18A<br />

Figure 18B<br />

Meter Socket<br />

Figure 19A<br />

Figure 19B<br />

Figure 20A<br />

KNOCKOUTS (inches):<br />

Figure 20B<br />

g: 1/4<br />

A: 1/2<br />

B: 1/2, 3/4<br />

L: 1/2, 3/4, 1, 1-1/4, 1-1/2<br />

N: 3/4, 1, 1-1/4, 1-1/2, 2<br />

P: 1, 1-1/4<br />

R: 1, 1-1/4, 1-1/2, 2<br />

S: 1, 1-1/4, 1-1/2, 2, 2-1/2<br />

X: 1-1/4, 1-1/2, 2, 2-1/2<br />

Z: 1-1/2, 2, 2-1/2<br />

EE: 2, 2-1/2, 3<br />

GG: 2-1/2, 3, 3-1/2<br />

HH: 2-1/2, 3, 3-1/2, 4<br />

AB: 1/4, 1/2, 7/8<br />

AC: 1/4, 1/2<br />

AD: 1-1/4, 1-1/2, 2, 2-1/2, 3<br />

AE: 1/4, 1/2, 3/4, 1, 1-1/4<br />

AF: 1, 1-1/2, 2, 2-1/2, 3<br />

AG: 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3<br />

AH: 1/4, 1/2, 3/4<br />

AI: 1, 1-1/4, 1-1/2, 2, 2-1/2, 3<br />

HD: x4.281 HUB 0P<br />

RX: x2.750 HUB 0P<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-29


Meter Centers<br />

Meter Socket Knockout Diagrams<br />

Meter Socket<br />

METER<br />

CENTERS<br />

2<br />

Figure 21A<br />

Figure 21B<br />

Figure 22<br />

Figure 23<br />

Figure 24<br />

KNOCKOUTS (inches):<br />

g: 1/4<br />

A: 1/2<br />

B: 1/2, 3/4<br />

L: 1/2, 3/4, 1, 1-1/4, 1-1/2<br />

N: 3/4, 1, 1-1/4, 1-1/2, 2<br />

P: 1, 1-1/4<br />

R: 1, 1-1/4, 1-1/2, 2<br />

S: 1, 1-1/4, 1-1/2, 2, 2-1/2<br />

X: 1-1/4, 1-1/2, 2, 2-1/2<br />

Z: 1-1/2, 2, 2-1/2<br />

EE: 2, 2-1/2, 3<br />

GG: 2-1/2, 3, 3-1/2<br />

HH: 2-1/2, 3, 3-1/2, 4<br />

AB: 1/4, 1/2, 7/8<br />

AC: 1/4, 1/2<br />

AD: 1-1/4, 1-1/2, 2, 2-1/2, 3<br />

AE: 1/4, 1/2, 3/4, 1, 1-1/4<br />

AF: 1, 1-1/2, 2, 2-1/2, 3<br />

AG: 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3<br />

AH: 1/4, 1/2, 3/4<br />

AI: 1, 1-1/4, 1-1/2, 2, 2-1/2, 3<br />

HD: x4.281 HUB 0P<br />

RX: x2.750 HUB 0P<br />

2-30<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Meter Centers<br />

Meter Socket Knockout Diagrams<br />

2 METER<br />

CENTERS<br />

Figure 25<br />

Figure 26<br />

Meter Socket<br />

Figure 27 Figure 28<br />

KNOCKOUTS (inches):<br />

Figure 29<br />

g: 1/4<br />

A: 1/2<br />

B: 1/2, 3/4<br />

L: 1/2, 3/4, 1, 1-1/4, 1-1/2<br />

N: 3/4, 1, 1-1/4, 1-1/2, 2<br />

P: 1, 1-1/4<br />

R: 1, 1-1/4, 1-1/2, 2<br />

S: 1, 1-1/4, 1-1/2, 2, 2-1/2<br />

X: 1-1/4, 1-1/2, 2, 2-1/2<br />

Z: 1-1/2, 2, 2-1/2<br />

EE: 2, 2-1/2, 3<br />

GG: 2-1/2, 3, 3-1/2<br />

HH: 2-1/2, 3, 3-1/2, 4<br />

AB: 1/4, 1/2, 7/8<br />

AC: 1/4, 1/2<br />

AD: 1-1/4, 1-1/2, 2, 2-1/2, 3<br />

AE: 1/4, 1/2, 3/4, 1, 1-1/4<br />

AF: 1, 1-1/2, 2, 2-1/2, 3<br />

AG: 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3<br />

AH: 1/4, 1/2, 3/4<br />

AI: 1, 1-1/4, 1-1/2, 2, 2-1/2, 3<br />

HD: x4.281 HUB 0P<br />

RX: x2.750 HUB 0P<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-31


Meter Centers<br />

Meter Socket Knockout Diagrams<br />

Meter Socket<br />

METER<br />

CENTERS<br />

2<br />

Figure 30<br />

Figure 31<br />

Figure 32<br />

KNOCKOUTS (inches):<br />

Figure 33 Figure 35<br />

g: 1/4<br />

A: 1/2<br />

B: 1/2, 3/4<br />

L: 1/2, 3/4, 1, 1-1/4, 1-1/2<br />

N: 3/4, 1, 1-1/4, 1-1/2, 2<br />

P: 1, 1-1/4<br />

R: 1, 1-1/4, 1-1/2, 2<br />

S: 1, 1-1/4, 1-1/2, 2, 2-1/2<br />

X: 1-1/4, 1-1/2, 2, 2-1/2<br />

Z: 1-1/2, 2, 2-1/2<br />

EE: 2, 2-1/2, 3<br />

GG: 2-1/2, 3, 3-1/2<br />

HH: 2-1/2, 3, 3-1/2, 4<br />

AB: 1/4, 1/2, 7/8<br />

AC: 1/4, 1/2<br />

AD: 1-1/4, 1-1/2, 2, 2-1/2, 3<br />

AE: 1/4, 1/2, 3/4, 1, 1-1/4<br />

AF: 1, 1-1/2, 2, 2-1/2, 3<br />

AG: 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3<br />

AH: 1/4, 1/2, 3/4<br />

AI: 1, 1-1/4, 1-1/2, 2, 2-1/2, 3<br />

HD: x4.281 HUB 0P<br />

RX: x2.750 HUB 0P<br />

2-32<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Meter Centers<br />

Meter Socket Knockout Diagrams<br />

2 METER<br />

CENTERS<br />

Meter Socket<br />

Figure 39<br />

Figure 40<br />

Figure 41<br />

Figure 44<br />

Figure 45 Figure 46<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-33


Meter Centers<br />

Meter Combination Catalog Number Logic<br />

Combination Meter Sockets<br />

2<br />

MC 30 40 B 1 200 S E C W<br />

METER<br />

CENTERS<br />

Main Ampere<br />

Rating<br />

Circuits<br />

(max. No. of circuits)<br />

Spaces<br />

(max. No. of 1" breakers)<br />

MM = Meter Main<br />

MC = Meter Load Center Combination<br />

1 = 1-Phase<br />

3 = 3-Phase<br />

ML or L = Main Lug<br />

MB or B = Main Breaker<br />

F/S = Flush / Surface Mounting<br />

R = Ringless (blank = ring type)<br />

E = EUSERC Approved<br />

D/C = UG Feed Only / OH/UG feed<br />

J = 5th Jaw<br />

B = Horn Bypass<br />

A = Aluminum Enclosure<br />

H = Double Hub Provision<br />

L = Lever Bypass Socket<br />

M = Field Addable Sub Feed Main<br />

N = OH Only Main Lug<br />

T = Feed Thru Lugs<br />

W = Wide Load Center Design<br />

X = Larger Utility Section<br />

Z = OH Feed, Load out Bottom Only<br />

Special Suffixes:<br />

GA = Georgia Power Compliant<br />

CS = Comb. Feed with Test Block Bypass<br />

DS = UG only Feed with Test Block Bypass<br />

E2 = Back-to-back EUSERC with External<br />

Disconnect and Internal Load Center<br />

EY = Commercial Test Block Bypass<br />

with OH only Feed<br />

CEY = Commercial Test Block Bypass<br />

with OH and UG Feed<br />

2-34<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Meter Centers<br />

Meter Combination Introduction<br />

Meter Mains<br />

Meter Load Center Combinations<br />

Meter Mains<br />

Siemens Meter Mains are UL Listed and available from 100A<br />

to 400A services. These Meter Mains utilize a cost effective<br />

construction that is preferable in non-EUSERC areas.<br />

ad Center Combinations<br />

mbo<br />

Welcome to the Combination Meter Socket Meter Section. Mains This section includes 4 product Meter categories, Load Center which Combinations each include their own set<br />

of featured products. Look for the icons below to help explain the Meter Side-By-Side<br />

application Mains and design of products on Meter that Load page. Center Combinations<br />

Over-Under Combo<br />

Over-Under<br />

Meter Mains<br />

Over-Under<br />

Side-By-Side<br />

EUSERC Meter Mains<br />

Siemens EUSERC Meter Mains are UL Listed and available<br />

from 100A to 400A services. These meter mains utilize designs<br />

that meet EUSERC requirements. Two constructions are<br />

Side-By-Side<br />

available. EUSERC Meter Mains<br />

Over-Under Combo<br />

Side-By-Side<br />

Over-Under Construction<br />

Side-By-Side<br />

Over-Under<br />

Over-Under Combo<br />

Over-Under<br />

These Siemens Meter Mains feature Meter Mains a classic<br />

Side-By-Side Meter Load Center Construction<br />

Combinations<br />

over-under construction. Available in 100A and<br />

These Siemens Meter Mains have a side-by-side<br />

125A versions.<br />

construction that is slightly larger in order to<br />

Meter Load Center Combinations<br />

meet EUSERC requirements.<br />

Side-By-Side Construction EUSERC Meter Mains<br />

Side-By-Side<br />

These Meter Mains utilize a cost effective sideby-side<br />

construction. Meter Mains combine<br />

EUSERC Meter Mains<br />

Side-By-Side<br />

Side-By-Side 400A 400A Construction<br />

These Siemens Meter Mains have side-by-side<br />

a socket to the left and main circuit Side-By-Side breaker<br />

construction that meets EUSERC design, and<br />

Over-Under Combo<br />

Over-Under<br />

Side-By-Side<br />

section to the right. Meter The Mains main breaker section Meter Load Center provide Combinations 400A service.<br />

includes 2 to 6 circuits.<br />

EUSERC Meter Load Center Combinations<br />

Side-By-Side<br />

Side-By-Side 400A<br />

Meter Load Center Combinations EUSERC Meter Mains EUSERC Meter Load Center Combinations<br />

Siemens Meter Load Center Combinations offer several Siemens Meter Load Center Combinations offer several<br />

different configurations and include a meter socket section and different configurations to meet a variety of installer demands.<br />

a load center EUSERC section. Meter Mains<br />

Side-By-Side<br />

Meter Mains These combos feature a Meter cost effective Load Center Combinations<br />

EUSERC Meter Load Over-Under Center These Combinations<br />

Combo Siemens combos Over-Under feature designs Side-By-Side that meet EUSERC<br />

construction that is preferable in non-EUSERC areas.<br />

requirements.<br />

Meter Load Center Combinations<br />

EUSERC Meter Load Center Combinations<br />

Over-Under Combination Construction<br />

Over-Under Between the Studs Construction<br />

Over-Under 14” Side-By-Side 14” Side-By-Side Full Load Center<br />

These Siemens Meter Load Center<br />

These Combos have a full width load center<br />

Side-By-Side<br />

Side-By-Side 400A<br />

Combinations feature a EUSERC over-under Meter Mains configuration<br />

section above, and a meter socket section<br />

with a unique trough allowing service from either<br />

below, in a 14.3" wide configuration that allows<br />

ad Center Combinations Side-By-Side Side-By-Side overhead Side-By-Side or underground 400A to the device.<br />

flush mounting between typical 16" on center<br />

Over-Under Combo<br />

Over-Under<br />

Side-By-Side<br />

stud construction. Surface mounting options<br />

Over-Under Combo<br />

Over-Under Construction Side-By-Side Over-Under EUSERC 14” Meter Load Side-By-Side Center 14” Combinations<br />

Side-By-Side available. Full Load Center Side-By-Side 400A<br />

Over-Under 14” Side-By-Side 14” Side-By-Side Full Load Center<br />

These Siemens Meter Load Center<br />

Combinations feature a classic over-under<br />

Side-By-Side Between the Studs Construction<br />

ions<br />

EUSERC Meter Load Center Combinations<br />

construction, but are for overhead feed only.<br />

These combos have a half width load center<br />

EUSERC Meter Mains Side-By-Side<br />

Side-By-Side 400A<br />

section to the right and a meter socket section<br />

Side-By-Side Construction<br />

to the left, in a 14.2" wide configuration that<br />

mbo<br />

Load Center<br />

Over-Under Side-By-Side 400A<br />

Side-By-Side<br />

These Siemens Meter Load Center<br />

allows flush mounting between typical 16" on<br />

Combinations have a side-by-side configuration.<br />

center stud construction. Surface mounting<br />

EUSERC Meter Load Center Combinations options available.<br />

der<br />

EUSERC<br />

-By-Side 400A<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Over-Under Combo<br />

Off-set Side-By-SideMeter Constuction<br />

Side-By-Side 400A<br />

These Siemens Meter<br />

Side-By-Side<br />

Load<br />

Full<br />

Center<br />

Load Center<br />

Combinations feature an offset meter to<br />

increase room for pulling conductors.<br />

Side-By-Side<br />

Over-Under 14” Side-By-Side 14”<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC Meter Load Center Combinations<br />

Over-Under<br />

Side-By-Side<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Side-By-Side 400A<br />

Side-By-Side<br />

Side-By-Side 400A<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Side-By-Side Full Load Center<br />

EUSERC<br />

EUSERC<br />

Side-By-Side 400A<br />

Side-By-Side Full Load Center Construction<br />

These Siemens Meter Load Center<br />

Combinations have a full width load center<br />

section to the right, and a meter socket section<br />

to the left. The overall width make this combo<br />

best suited for surface mounting.<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Side-By-Side 400A<br />

EUSERC<br />

EUSERC<br />

Side-By-Side 400A<br />

2 METER<br />

CENTERS<br />

Side-<br />

Sid<br />

er Combinations<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

Over-Under 14” Side-By-Side 14”<br />

EUSERC<br />

EUSERC<br />

Side-By-Side Full Load Center<br />

Side-By-Side Full Load Center<br />

EUSERC<br />

Side-By-Side 400A<br />

Side-By-Side 400A<br />

Side-By-Side 400A Construction<br />

These Siemens Meter Mains have side-by-side<br />

construction that meets EUSERC design, and<br />

provide 400A service. Available with 16 to 42<br />

circuits.<br />

e 14”<br />

Side-By-Side Full Load Center<br />

Side-By-Side 400A<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-35<br />

RC


Meter Mains<br />

Meter Load Center Combinations Meter Mains<br />

Meter Centers<br />

Surface Mount Meter-Mains, 1-Phase, 3-Wire 120/240V AC<br />

Side-By-Side<br />

Over-Under Combo<br />

Over-Under<br />

Side-By-Side Side-By-Side<br />

2<br />

METER<br />

CENTERS<br />

n UL listed<br />

n Pad locking provisions on all devices<br />

n Horn bypass and 5th jaw available as noted<br />

n Side hinged door with one screw removal where shown<br />

n Suitable for use only as service entrance equipment<br />

n 22,000 AIC rated, or as noted<br />

n RX type (or) HD type hub provision on top end wall as noted<br />

n Contact local utility to confirm meter socket placement prior to<br />

installation<br />

n See end of section for dimensions and wiring diagrams<br />

EUSERC Meter Mains<br />

EUSERC Meter Load Center Combinations<br />

MM0202B1200RJBX MM0406L1200H MM0202B1200<br />

EUSERC<br />

EUSERC<br />

Side-By-Side<br />

EUSERC<br />

EUSERC<br />

Side-By-Side 400A<br />

EUSERC<br />

EUSERC<br />

EUSERC Meter Mains<br />

EUSERC<br />

Side-By-Side<br />

S<br />

EUSERC Meter Load Ce<br />

Over-Under 14” Side-By-Side 14”<br />

Side-By-Side Full Load Center<br />

Side-By-Side 400A<br />

EUSERC<br />

Over-Under 14”<br />

Side-By<br />

125, 150, and 200A meter main<br />

(factory installed), side hinge door.<br />

200A meter main (field<br />

added), side hinge door<br />

125 and 200A meter mains,<br />

side hinge door<br />

Catalog Number<br />

Amp<br />

Rating<br />

(Cont.)<br />

Utility<br />

Incoming<br />

Bypass<br />

Type<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits<br />

Dimensions<br />

(inches)<br />

H W D<br />

Main<br />

Breaker<br />

Short<br />

Circuit<br />

Rating<br />

Hub<br />

Provision<br />

Meter-Main Breaker with Field Installed Breaker, Ring Style, 100-125amp<br />

MM0202ML1100S 100 OH None 2 2 18.0 7.4 4.0 QP type 10,000 RX — Ring<br />

MM0202ML1125H 125 OH/UG 17.0 16.0 5.0 QP(H) type 22,000 2-RX EC5J Ring<br />

Meter-Main Breaker with Factory Installed Breaker, 125-200amp (Side-by-Side construction)<br />

MM0202B1150<br />

Ring<br />

150<br />

QN2150H<br />

MM0202B1150R<br />

Ringless<br />

OH/UG None 2 2 17.0 16.0 5.0<br />

22,000 RX EMC5J<br />

MM0202B1200<br />

Ring<br />

200 QN2200H<br />

MM0202B1200R<br />

Ringless<br />

MM0202B1125RJB 125<br />

Q2125H<br />

Ringless<br />

MM0202B1150RJB 150 16.0 5.0 QN2150H Ringless<br />

MM0202B1200RJB 200<br />

OH/UG<br />

Horn<br />

QN2200H Ringless<br />

Bypass<br />

2 2 17.0<br />

22,000 RX Installed<br />

MM0202B1125RJBX 125<br />

Q2125H<br />

Ringless<br />

MM0202B1150RJBX 150 18.5 5.2 QN2150H Ringless<br />

MM0202B1200RJBX 200 QN2200H Ringless<br />

Meter-Main Breaker with Field Installed Main & Subfeed Breaker up to 200amp (Side-by-Side construction)<br />

MM0406L1200GA<br />

20.0 21.2 5.0 Main Lug<br />

RX Cl.<br />

Plate<br />

Ring<br />

MM0406L1200H<br />

None<br />

17.2 5.0<br />

EMC5J<br />

MM0406L1200RH 200 OH/UG<br />

4 6<br />

22,000<br />

Ringless<br />

19.8<br />

1-QN or<br />

MM0406L1200RGA 21.8 5.0 2-RX<br />

2-QP type<br />

Ringless<br />

MM0406L1200RHJB <br />

Horn<br />

Bypass<br />

17.2 5.0 Installed Ringless<br />

5th<br />

Jaw<br />

Cover<br />

Type<br />

Over/Under<br />

Side-by-Side<br />

Georgia Power approved<br />

2-36<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Meter Mains<br />

Meter Load Center Combinations<br />

Meter Mains<br />

Meter Centers<br />

Revised on 03/31/18<br />

Surface Mount Meter-Mains, 1-Phase, 3-Wire 120/240V AC<br />

Side-By-Side<br />

Over-Under Combo<br />

Over-Under<br />

Side-By-Side Side-By-Side<br />

n UL listed<br />

n Pad locking provisions on all devices<br />

n Side hinged door with one screw removal where shown<br />

n Suitable for use only as service entrance equipment<br />

n 22,000 AIC rated, or as noted<br />

n RX type (or) HD type hub provision on top end wall as noted<br />

n Contact local utility to confirm meter socket placement prior<br />

to installation<br />

n See end of section for dimensions and wiring diagrams<br />

EUSERC Meter Mains<br />

EUSERC<br />

EUSERC<br />

Side-By-Side<br />

Side-By-Side 400A<br />

EUSERC Meter Load Center Combinations<br />

EUSERC Meter Mains<br />

EUSERC<br />

Side-By-Side<br />

2 METER<br />

CENTERS<br />

Sid<br />

EUSERC Meter Load Cen<br />

MM0202B1200JLX<br />

MM0404L1400RLM<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

Side-By-Side Full Load Center<br />

Side-By-Side 400A<br />

EUSERC<br />

Over-Under 14”<br />

Side-By-S<br />

200A meter main with lever bypass<br />

400A meter main, side hinge door,<br />

provisions for two field installed mains<br />

Catalog Number<br />

Amp<br />

Rating<br />

(Cont.)<br />

Utility<br />

Incoming<br />

Bypass<br />

Type<br />

No. of<br />

Spaces<br />

No. of<br />

Spaces<br />

Dimensions<br />

(inches)<br />

H W D<br />

Main Breaker<br />

Short<br />

Circuit<br />

Rating<br />

Meter-Main Breaker with Lever Bypass, Ringless, 200-400amp (Side-by-Side construction)<br />

MM0202B1200JLX<br />

QN2200H<br />

200<br />

2 2 21.1 17.2 5.3<br />

Provision for<br />

MM0202L1200JLX<br />

QN, QP, MP-T, or<br />

MD-T Type<br />

MM0404B11515RL<br />

(2) QN2150RH<br />

OH/UG HQ<br />

QN2200RH and<br />

MM0404B12010RL<br />

Lever<br />

Q2100H<br />

Bypass<br />

29 27 6<br />

MM0404B1400RLM<br />

(2) QN2200RH<br />

320 4 4<br />

(2) Provisions for<br />

MM0404L1400RLM<br />

QNR or QP Type<br />

(2) Provisions for<br />

MM0404L1400SDL UG 40 30 6.5<br />

QN or QP Type<br />

22,000<br />

65,000<br />

Hub<br />

Provision<br />

RX (Top)<br />

HC (Bot)<br />

HD<br />

22,000 —<br />

Meter-Main Breaker with Lever Bypass, Ringless, 100-400amp (Over/Under construction)<br />

MM0202B1100RLC<br />

MM0202L1125RLC<br />

100<br />

125<br />

27<br />

HQ<br />

MM0202B1200RLC<br />

OH/UG Lever<br />

Bypass<br />

2 2<br />

MM0202L1200RLC<br />

200<br />

38<br />

Q2100<br />

Provision for QP<br />

or MP-T Type<br />

36 16 5 QN2200H<br />

Provision for<br />

QN, QP, MP-T, or<br />

MD-T Type<br />

5th Jaw<br />

Installed<br />

H35815-2<br />

Cover<br />

Type<br />

Ringless<br />

22000 RX Installed Ringless<br />

Meter-Main Breaker with Lever Bypass, Ringless, 100-200amp, 3-phase (Over/Under construction)<br />

MM0303B3100RLC<br />

26 13.5 5.3 Q3100<br />

100<br />

HQ<br />

3 3<br />

Provision for QP<br />

—<br />

MM0303L3100RLC OH/UG Lever<br />

26 13.5 5.3 10000 RX<br />

or MP-T Type<br />

Bypass<br />

MM0303B3200RLC 200 0 0 38 16 5 QR23B200 Installed<br />

Ringless<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-37


Meter MainsMeter Mains<br />

Meter Load Meter Center Load Combinations<br />

Center Combinations<br />

Meter Centers<br />

Side-By-Side<br />

Side-By-Side<br />

Surface Mount, Over/Under Meter-Load Center Combination, 1-Phase, 3-Wire 120/240V AC<br />

Over-Under Combo<br />

Over-Under Combo<br />

Over-Under<br />

Over-Under<br />

Side-By<br />

2<br />

n UL listed<br />

n Overhead and underground feed applications<br />

n Load wires bottom or back exit only<br />

n 22,000 AIC rated, or as noted<br />

n Pad locking provisions on all devices<br />

MC0606L1200R MC0408B1150T MC1020B1100S<br />

n Side hinge doors removable by backing out only one screw<br />

EUSERC Meter Mains<br />

n Suitable for use only EUSERC as Meter service Mains entrance equipment<br />

n Contact local utility to confirm meter socket placement prior<br />

to installation<br />

n See end of section for dimensions and wiring diagrams<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Side-By-Side<br />

Side-By-Side 400A<br />

Side-By-Side<br />

Side-By-Side 400A<br />

MC2040B1200S<br />

METER<br />

CENTERS<br />

EUSERC Meter Load Center Combinations<br />

EUSERC Meter Load Center Combinations<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

EUSERC<br />

EUSERC<br />

Side-By-Side Full Load Center<br />

EUSERC<br />

EUSERC<br />

Side-By-Side 400A<br />

200A, main lug, 6 circuit<br />

(Twelve 1" spaces), for use<br />

with up to six 2-pole breakers<br />

150 or 200A, main breaker,<br />

four 1" spaces, feed thru<br />

lugs provided<br />

100 or 200A, main breaker,<br />

10 space, 20 circuit,<br />

overhead feed<br />

Over-Under 14” Side-By-Side 14”<br />

Side-By-Side Full Load Center<br />

100 or 200A, main breaker,<br />

20 space, 40 circuit,<br />

overhead feed<br />

Side-By-Side 400A<br />

Catalog Number<br />

Amp<br />

Rating<br />

(Cont.)<br />

Utility<br />

Incoming<br />

Bypass<br />

Type<br />

No. of<br />

Spaces<br />

Meter-Load Center Combination, 125-200amp <br />

No. of<br />

Circuits<br />

Dimensions (inches)<br />

H W D<br />

Main<br />

Breaker<br />

Short<br />

Circuit<br />

Rating<br />

Hub<br />

Provision<br />

MC0408B1150T Ring<br />

150<br />

MBK150<br />

MC0408B1150RT <br />

Ringless<br />

OH/UG None 4 8 30.0 14.0 5.0<br />

22,000 RX EC5J2<br />

MC0408B1200T Ring<br />

200 MBK200<br />

MC0408B1200RT <br />

Ringless<br />

MC0816B1150CT 150<br />

MBK150<br />

Ring<br />

MC0816B1200CT 200 MBK200<br />

None<br />

RX EC5J2<br />

MC0816B1150RCT 150 MBK150<br />

8 16 32.0 14.0 5.0<br />

Ringless<br />

MC0816B1200RCT 200 MBK200<br />

OH/UG<br />

22,000<br />

MC0816B1150RJBT 150<br />

MBK150<br />

RX-top,<br />

Horn<br />

Installed Ringless<br />

MC0816B1200RJBT 200 MBK200<br />

HC-bot<br />

MC3042B1200RC<br />

None<br />

200<br />

MC3042B1200RJB<br />

Horn<br />

30 42 42.0 14.0 5.0 EQ9985 RX EC5J2 Ringless<br />

MC0816B1150T 150<br />

QN2150RH<br />

Ring<br />

MC0816B1200T 29.0 12.0 5.2 QN2200RH<br />

EMC5J<br />

200<br />

None<br />

MC0816B1200RT OH<br />

8 16<br />

QN2200RH 22,000 RX<br />

Ringless<br />

MC0816B1200RTZ<br />

32.0 14.0 5.0 EQ8695 EC5J2<br />

200<br />

MC0816B1200RTB Horn 29.0 12.0 5.0 QN2200RH EMC5J<br />

Ringless<br />

MC2040B1150RC 150<br />

MBK150<br />

None<br />

EC5J2<br />

MC2040B1200RC 200 MBK200<br />

OH/UG<br />

20 40 36.0 14.0 5.0<br />

22,000 RX<br />

MC2040B1150RJBC 150 Horn<br />

MBK150<br />

Installed<br />

MC2040B1200RJBC 200 Bypass<br />

MBK200<br />

Ringless<br />

MC0606L1200R None<br />

EC5J2<br />

MC0606L1200RA <br />

27.0 14.0 5.0<br />

200 OH/UG<br />

12 6<br />

Main Lug 22,000 RX<br />

Ringless<br />

MC0606L1200RJB Horn Installed<br />

MC0606L1200RN None 29.0 12.0 5.2 EC5J2<br />

Over-Under Construction Meter Load Center Combinations <br />

Old Catalog<br />

Number<br />

JA1020B1100F<br />

New Catalog<br />

Number<br />

MC1020B1100F<br />

Amps<br />

Max<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits<br />

Cover<br />

Type Mounting Service<br />

Flush<br />

Bypass<br />

Type<br />

5th<br />

Jaw<br />

Dimensions<br />

H W D<br />

JA1020B1100S MC1020B1100S Surface<br />

100 10 20 Ring<br />

— MC1020B1100FZ Flush<br />

OH none 19.4 12.1 4.4 4<br />

— MC1020B1100SZ Surface<br />

JA2040B1200F MC2040B1200F<br />

Flush<br />

5.1<br />

JA2040B1200S MC2040B1200S Surface 4.4<br />

200 20 40 Ring<br />

OH none 30.5 14.3<br />

— MC2040B1200FZ Flush 5.1<br />

5<br />

— MC2040B1200SZ Surface 4.4<br />

Cover<br />

Type<br />

Figure<br />

No main breaker provided. Accepts QN or QP type 2 or<br />

4-pole breakers.<br />

Suitable for use as service entrance equipment when not<br />

more than six disconnecting means are provided and<br />

when not used as a lighting an appliance panel board.<br />

Due to wire space restrictions on the trough side, the left<br />

side of the interior is limited to a 60A max branch.<br />

Aluminum enclosure.<br />

Feed thru lugs included.<br />

Dimensional and other technical data is applicable<br />

for "New Catalog Numbers" ONLY.<br />

Horizontal barrier installed—no top exit of load conductors<br />

allowed. Check with sales office for utility<br />

approved.<br />

UL Listed for Siemens and Murray breakers.<br />

Old Catalog Numbers JA1020B1100SP and<br />

JA2040B1200SP are obsolete with no replacement.<br />

2-38<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Meter Mains<br />

Meter Load Center Combinat<br />

Meter Centers<br />

Utility Specific, Over/Under Meter-Load Center Combination, 1-Phase, 3-Wire 120/240V AC<br />

Side-By-Side<br />

Over-Under Combo<br />

Over-Un<br />

n UL listed<br />

n Overhead and underground feed applications<br />

n Load wires bottom or back exit only<br />

n 22,000 AIC rated, or as noted<br />

n Pad locking provisions on all devices<br />

n Side hinge doors removable by backing out only one screw<br />

n Suitable for use only as service entrance equipment<br />

n Contact local utility to confirm meter socket placement prior<br />

to installation<br />

n See end of section for dimensions and wiring diagrams<br />

MC0816B1200RTD<br />

EUSERC Meter Mains<br />

EUSERC<br />

EUSERC<br />

Side-By-Side<br />

Side-By-Side 400A<br />

EUSERC Meter Load Center Combinations<br />

2 METER<br />

CENTERS<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

Side-By-Side Full Load Center<br />

Side-B<br />

200A offset design with<br />

feed thru lugs<br />

Catalog Number<br />

Amp<br />

Rating<br />

(Cont.)<br />

Utility<br />

Incoming<br />

Bypass<br />

Type<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits<br />

Dimensions (inches)<br />

H W D<br />

Main<br />

Breaker<br />

Short<br />

Circuit<br />

Rating<br />

Meter-Load Center Combination, 150-200amp, Sidewire (Underground Feed Only) <br />

Hub<br />

Provision<br />

5th<br />

Jaw<br />

Cover<br />

Type<br />

MC0606L1200RAD None 6 6 25.0<br />

Main Lug 10,000<br />

200 UG<br />

17.0 5.2<br />

MC0816B1200RTD None 8 16 29.0 MBK200 22,000<br />

HC-bot EC5J2 Ringless<br />

Meter-Load Center Combination Approved for Georgia Power, 150-200A<br />

MC0408B1150RGA 150<br />

MBK150<br />

4 8 33.5<br />

MC0408B1200RGA MBK200<br />

200<br />

MC0606L1200RGA OH/UG None 12 6 30.5 15.0 5.1 Main Lug<br />

MC0816B1150RGA 150<br />

MBK150<br />

8 16 35.5<br />

MC0816B1200RGA 200 MBK200<br />

22,000<br />

RX-top,<br />

HC-bot<br />

EC5J2<br />

Ringless<br />

Suitable for use as service entrance equipment when<br />

not more than six disconnecting means are provided<br />

and when not used as a lighting an appliance panel<br />

board.<br />

Due to wire space restrictions on the trough side, the<br />

left side of the interior is limited to a 60A max branch.<br />

Aluminum enclosure.<br />

Feed thru lugs included.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-39


Meter Mains<br />

Meter Load Center Combina<br />

Meter Centers<br />

Lever Bypass, Over/Under Meter-Load Center Combo, 1-Phase, 3-Wire 120/240V AC<br />

Side-By-Side<br />

Over-Under Combo<br />

Over-U<br />

MC2040B1200JLC<br />

EUSERC Meter Mains<br />

2<br />

METER<br />

CENTERS<br />

n UL listed<br />

n Talon HQ lever bypass (heavy duty)<br />

n 125-200 amp<br />

n Overhead and underground feed applications<br />

n Load wires bottom or back exit only<br />

n 22,000 AIC rated, or as noted<br />

n Pad locking provisions on all devices<br />

n Side hinge doors removable by backing out only one screw<br />

n Suitable for use only as service entrance equipment<br />

n Contact local utility to confirm meter socket placement prior<br />

to installation<br />

n See end of section for dimensions and wiring diagrams<br />

n See page 2-42 for Solar Ready lever bypass<br />

n See page 2-44 for 300-400A lever bypass<br />

200A meter load center<br />

with lever bypass<br />

EUSERC<br />

EUSERC<br />

Side-By-Side<br />

Side-By-Side 400A<br />

EUSERC Meter Load Center Combinations<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14” Side-By-Side Full Load Center<br />

Side<br />

Catalog Number<br />

Amp<br />

Rating<br />

(Cont.)<br />

Utility<br />

Incoming<br />

Bypass<br />

Type<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits<br />

Dimensions (inches)<br />

H W D<br />

Main<br />

Breaker<br />

Short<br />

Circuit<br />

Rating<br />

Hub<br />

Provision<br />

5th<br />

Jaw<br />

Cover<br />

Type<br />

Meter-Load Center Combination, 125-200amp, Lever Bypass <br />

MC0408B1200JLT 200<br />

Lever 4 8 30.5 16.0 5.0 EQ9985<br />

RX<br />

MC0816B1150JLT 150<br />

MBK150<br />

8 16<br />

MC0816B1200JLT 200 OH/UG HQ<br />

MBK200<br />

Lever<br />

32.1 14.3 5.2<br />

MC1224B1125JLC 125<br />

Bypass<br />

MBK125<br />

12 24<br />

MC1224B1200JLC 200 MBK200<br />

MC2040B1150JLC 150<br />

MBK150<br />

HQ 20 40 36.1<br />

MC2040B1200JLC<br />

OH/UG Lever<br />

14.3 5.2<br />

200 Bypass<br />

MBK200<br />

MC3042B1200JLC 30 42 42.1<br />

22,000<br />

RX-top,<br />

HC-bot<br />

Installed<br />

Ringless<br />

Due to wire space restrictions on the trough side, the<br />

left side of the interior is limited to a 60A max branch.<br />

Feed thru lugs included.<br />

2-40<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Meter Mains<br />

Meter Load Center Combinations<br />

Meter Centers<br />

Revised on 03/31/18<br />

Surface Mount, Side-by-Side Meter-Load Center Combination,<br />

Side-By-Side<br />

1-Phase, 3-Wire 120/240V AC<br />

Over-Under Combo<br />

Over-Under<br />

Side-By-Side<br />

n UL listed<br />

n Suitable for use only as service entrance equipment<br />

EUSERC Meter Mains<br />

n 22,000 AIC Rated<br />

n Contact local utility to confirm meter socket approval prior<br />

n Pad locking provisions on all devices<br />

to installation<br />

n<br />

n Side hinge doors removable by backing out only one screw<br />

See end of section for dimensions and wiring diagrams<br />

MC0816B1200TH (shown)<br />

MC0816B1XXX(R)TH<br />

MC0816B1400RLTM<br />

MC0816B1350RLTM<br />

EUSERC<br />

Side-By-Side<br />

EUSERC<br />

MC3042B1400SDL<br />

Side-By-Side 400A<br />

MC2442B1400SDB<br />

2 METER<br />

CENTERS<br />

EUSERC Meter Load Center Combinations<br />

200A OH/UG feed, 8 circuit,<br />

with feed thru lugs.<br />

EUSERC<br />

One factory installed main,<br />

provisions for up to 200A field<br />

400A meter load center<br />

installed main, 8 circuits, lever Over-Under 14” combination, Side-By-Side 14” 30 space/ Side-By-Side Full Load Center<br />

bypass.<br />

40 circuit lever bypass<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

400A bolt in K4 socket with<br />

Side-By-Side 400A<br />

400A main<br />

Catalog Number<br />

Amp<br />

Rating<br />

(Cont.)<br />

Utility<br />

Incoming<br />

Bypass<br />

Type<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits<br />

Dimensions (inches)<br />

H W D<br />

Meter-Load Center Combination, 150-200amp, Full Loadcenter Width<br />

Main<br />

Breaker<br />

Short<br />

Circuit<br />

Rating<br />

Hub<br />

Provision<br />

MC0816B1150TH 150<br />

QN2150RH<br />

Ring<br />

MC0816B1200TH 200 QN2200RH<br />

OH/UG None 8 16 21.0 22.9 5.0<br />

22,000 2-RX EMC5J<br />

MC0816B1150RTH 150 QN2150RH<br />

Ringless<br />

MC0816B1200RTH 200 QN2200RH<br />

MC1224B1125 125<br />

16.0 22.89 5.0 Q2125H<br />

RX EMC5J Ring<br />

OH/UG None 12 24<br />

EQ9575/ 22,000 RX-top<br />

MC1224B1125R 125 32.0 14.0 5.0<br />

EC5J2 Ringless<br />

EQ9677<br />

HC-bot<br />

MC2040B1150 150<br />

QN2150RH<br />

Ring<br />

MC2040B1200 200 QN2200RH<br />

20 40 18.0 22.9 5.0<br />

RX<br />

MC2040B1150R 150 QN2150RH<br />

OH/UG None<br />

22,000<br />

EMC5J<br />

MC2040B1200R<br />

QN2200RH<br />

Ringless<br />

MC3040B1200R 200<br />

30 40 24 23.5 5.3 QN2200RH RX-top<br />

MC4040B1200R 40 40 28 23.5 5.3 QN2200RH<br />

HC-bot<br />

Meter-Load Center Combination, 350-400amp, Lever Bypass<br />

MC0408B1400RLTM 4 8<br />

QN2200H<br />

HQ<br />

MC0816B1350RLTM 320 OH/UG<br />

8 16 29.0 27.0 6.0 QN2150H<br />

Lever<br />

MC0816B1400RLTM 8 16 QN2200H<br />

Meter-Load Center Combination, 400amp, Lever Bypass, Underground Feed Only<br />

5th<br />

Jaw<br />

Cover<br />

Type<br />

22,000 HD H35815-2 Ringless<br />

MC0816B1400SDL<br />

8 16 39.7 30.2 6.4<br />

(1) QN &<br />

Provisions for<br />

MC2442B1400SDL 320 UG<br />

(1)QN or (1)QP<br />

HQ<br />

24 42 39.5 30.3 6.0 JXD22B400<br />

Lever<br />

(1) QN &<br />

22,000 HD H35815-2 Ringless<br />

MC3042B1400SDL 30 42 39.7 30.2 6.4 Provisions for<br />

(1)QN or (1)QP<br />

Meter-Load Center Combination, 400amp, K4 Bolt-In Meter Socket, Underground Feed Only<br />

MC2442B1400SDB<br />

24 42<br />

Bolt In<br />

400 K4<br />

UG<br />

No Bypass<br />

MC3042B1400SDB 30 42<br />

39.7 30.2 6.4<br />

JXD22B400<br />

Factory<br />

QN2200RH<br />

Field QP(H),<br />

QNR(H)<br />

22,000 HD<br />

—<br />

—<br />

Ringless<br />

Feed thru lugs included.<br />

Bolt-in meter socket. This device should not be confused with class<br />

320amp lever bypass devices. Device can not be converted to lever<br />

bypass. Installer should ensure device approval prior to installation.<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-41


EUSERC EUSERC Meter Mains Meter Mains<br />

Meter Centers<br />

Revised on 03/31/18<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC Compliant Side-by-Side Meter-Main Breaker, 1-Phase, 3-Wire 120/240V AC <br />

Side-By-Side Side-By-Side<br />

Side-By-Side Side-By-Side 400A 400A<br />

2<br />

METER<br />

CENTERS<br />

n UL listed<br />

n Designed to meet EUSERC standards<br />

n Underground Feed Applications (some with OH provisions)<br />

n Load wiring may exit top or bottom<br />

n 22,000 AIC Rated<br />

n Pad locking provisions on all devices<br />

MM0202B1100ESC<br />

MM0202B1200ESC<br />

n Surface and semi-flush units available<br />

n Side hinge door removable by backing out only one screw<br />

n Suitable for use only as service entrance equipment<br />

n Contact local utility to confirm meter socket approval<br />

prior to installation<br />

n See end of section for dimensions and wiring<br />

Over-Under 14” Side-By-Side 14”<br />

diagrams<br />

MM0404L1400SC<br />

EUSERC EUSERC Meter Load Meter Center Load Combinations<br />

Center Combinations<br />

EUSERC<br />

EUSERC<br />

MM0404L1400SCS<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14” Side-By-Side Side-By-Side Full Load Ce F<br />

100A factory installed<br />

main breaker<br />

200A factory installed<br />

main breaker<br />

400A with provisions for up<br />

to (2) 200A disconnects<br />

400A with provisions for up to (2)<br />

200A disconnects with bypass<br />

EUSERC Compliant Meter-Main Breaker, Factory and Field Options listed, 125-200amp <br />

Old Cat Number<br />

New Cat Number<br />

Utility<br />

Incoming<br />

Bypass<br />

Type<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits<br />

Dimensions<br />

H W D<br />

Main<br />

Breaker<br />

Short<br />

Circuit<br />

Rating<br />

Mounting<br />

MM0406L1125FEC MM0202L1125EFC Provision<br />

Flush<br />

OH/UG none 2 2 23.6 14.5 5 for QP or 22,000<br />

MM0406L1125SEC MM0202L1125ESC MP-T type<br />

Surface<br />

MM0406L1200FEC MM0202L1200EFC 7<br />

Provision<br />

Flush<br />

for QN, QP,<br />

OH/UG none 2 2 28.6 14.5<br />

22,000<br />

MD-T, or<br />

MM0406L1200SEC MM0202L1200ESC 5 Surface<br />

MP-T type<br />

N/A MM0202B1100ESC OH/UG none<br />

Q2100H<br />

2 2 23.6 14.5 5<br />

22,000 Surface<br />

N/A MM0202B1200ESC QN2200H<br />

Hub<br />

Provisions<br />

RX (top) /<br />

HC (bot)<br />

RX (top) /<br />

HC (bot)<br />

RX (top) /<br />

HC (bot)<br />

5th Jaw<br />

EMC5J<br />

EMC5J<br />

EMC5J<br />

Cover<br />

Type<br />

Ring<br />

Ring<br />

Ring<br />

Catalog Number<br />

Amp<br />

Rating<br />

(Cont.)<br />

Utility<br />

incoming<br />

Bypass<br />

Type<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits<br />

Dimensions (in.)<br />

H W D<br />

Main Breaker<br />

Short<br />

Circuit<br />

Rating<br />

Mounting<br />

EUSERC Compliant Meter-Main Breaker, Field Installed Main Main Breakers, 400amp max. (1)<br />

Hub<br />

Provision<br />

HD (top)<br />

MM0404L1400SC<br />

OH/UG<br />

39.7 33.2 6.5<br />

Surface<br />

None<br />

HD (bot)<br />

MM0404L1400FD UG 39.7 30.2 7.4<br />

(2) Provisions<br />

Flush HD (bot)<br />

320<br />

4 2<br />

for QNR or 22,000<br />

MM0404L1400SCS<br />

OH/UG<br />

QP Type<br />

HD (top)<br />

39.7 33.2 6.5 Surface<br />

Manual<br />

HD (bot)<br />

MM0404L1400FDS UG 39.7 30.2 7.4 Flush HD (bot)<br />

EUSERC Compliant Meter-Main Breaker, Single Main Disconnect, 400amp max.<br />

MM0202B1400SC<br />

OH/UG<br />

40 33.2 6.5<br />

None<br />

MM0202B1400SD UG 40 30.2 6.5<br />

MM0202B1400SCS<br />

OH/UG<br />

40 33.2 6.5<br />

320<br />

Manual 0 0<br />

MM0202B1400SDS UG 40 30.2 6.5<br />

MM0202B1400SCL<br />

OH/UG<br />

40 33.2 6.5<br />

Lever<br />

MM0202B1400SDL UG 40 30.2 6.5<br />

JXD22B400 22,000 Surface<br />

HD (top)<br />

HD (bot)<br />

5th<br />

Jaw<br />

Cover<br />

Type<br />

— Ring<br />

— Ring<br />

a Main breaker not included.<br />

b Flush adjustable for 2x4 walls only.<br />

Dimensional and other technical data is applicable<br />

for "New Catalog Numbers" ONLY.<br />

UL Listed for Siemens and Murray breakers.<br />

2-42<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Meter Centers<br />

SOLAR Ready, Meter-Load Center Combination Overview<br />

Wide Variety of meter socket configurations are available.<br />

Lever Bypass and EUSERC configurations shown.<br />

n 60 amp maximum input<br />

n Dedicated alternative energy input<br />

n Power feeds ahead of service disconnect on load side of meter socket<br />

n Eliminates need to de-rate main breaker/bussing<br />

2 METER<br />

CENTERS<br />

OH/UG Feed<br />

HQ Heavy Duty lever bypass<br />

Adjustable flush rails<br />

Raised basepan<br />

24-1” spaces. Expanded for<br />

arc-fault breakers<br />

Raised neutral bar<br />

200 Amp main disconnect<br />

Removable trough<br />

Instawire neutral bars<br />

Side hinged doors<br />

OH/UG Feed<br />

MC2442S1200FC<br />

EUSERC<br />

MC2040S1200JLC<br />

Lever Bypass<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-43


EUSERC Meter Load Center Combinations<br />

EUSERC Meter Load Center Combinations<br />

Meter Mains<br />

Meter Load Center Combinations<br />

Meter Mains<br />

Meter Load Center Meter Combinations<br />

Mains<br />

Meter Centers<br />

Revised on 03/31/18<br />

Side-By-Side<br />

Over-Under 14” Side-By-Side 14”<br />

SOLAR Ready, Meter-Load Center Combination, 1-Phase, 3-Wire 120/240V AC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Side-By-Side<br />

Over-Under<br />

Over-Under<br />

14” Side-By-Side 14”<br />

Side-By-Side Full Combo Load Center<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Side-By-Side Over-Under Full Load Center Combo Side-By-Side<br />

Over-Under<br />

Side-By-Side Over-Under 400A<br />

Side-By-Side 400A<br />

Side-By-Side<br />

Side-B<br />

2<br />

METER<br />

CENTERS<br />

n UL listed<br />

n For overhead and underground feed applications<br />

n 22,000 AIC Rated<br />

n Pad locking provisions on all devices<br />

n Surface and semi-flush units available - semi flush rails<br />

are depth adjustable for 2x6 studs<br />

n Side hinge door removable by backing out only one screw<br />

MC3040S1200SC<br />

MC4040S1200SC<br />

n Load wiring may exit top EUSERC or Meter bottom Mains<br />

EUSERC Meter Mains<br />

n Suitable for use only as service entrance equipment<br />

n Ring and Ringless type meter covers<br />

n Contact local utility to confirm meter socket approval prior<br />

to installation<br />

Side-By-Side<br />

Side-By-Side 400A<br />

n Side-By-Side See end of Side-By-Side section 400Afor dimensions and wiring diagrams<br />

n Devices accept Siemens & Murray circuit breakers<br />

MC0816S1200SCT MC2040S1200SZ EUSERC Meter Load Center Combinations MM020251200H<br />

MM020251200RHJ<br />

MM020251200RJB<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC Meter Load Center Combinations<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Side-By-Side Full Load Center<br />

EUSERC Meter Mains<br />

EUSERC<br />

Side-By-Side<br />

EUSERC<br />

Side-By-Side 400A<br />

Sid<br />

EUSERC Meter Load Cen<br />

Over-Under 14” Side-By-Side 14”<br />

Side-By-Side Full Load Center<br />

Side-By-Side 400A<br />

EUSERC<br />

Over-Under 14”<br />

Side-By-Si<br />

Catalog Number<br />

Amp<br />

Rating<br />

(Cont.)<br />

Aux.Input<br />

Max./<br />

Breaker Type<br />

Utility Bypass<br />

Incoming Type<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits<br />

Dimensions<br />

(inches)<br />

H W D<br />

Main<br />

Breaker<br />

Short<br />

Circuit<br />

Rating<br />

EUSERC Compliant Meter-Load Center Combination, 200amp with Alternate Energy Input &<br />

Full Load Center Width (Side-by-Side Construction)<br />

MC3040S1200SC<br />

100A / QP(H)<br />

30 40<br />

200<br />

OH/UG None<br />

MC4040S1200SC MP-(H)T<br />

40 40<br />

35.7 21.0 5.1 QN2200RH 22,000<br />

EUSERC Compliant Meter-Load Center Combination, 200amp with Alternate Energy Input,<br />

Between Studs Width (Side-by-Side Construction)<br />

MC0816S1200SCT 200<br />

MC2442S1200SC<br />

60A / QP(H)<br />

MP-(H)T<br />

100A / QP(H)<br />

MP-(H)T<br />

OH/UG<br />

None<br />

8 16 40.7 14.5 7.1<br />

24 42 40.7 14.5 7.1<br />

MC2442S1200FC <br />

Meter-Load Center Combination, 200amp with Alternate Energy Input,<br />

Overhead Feed Only (Over/Under Construction)<br />

MC2040S1200SZ 200<br />

100A / QP(H)<br />

MP-(H)T<br />

MBK200 22,000<br />

OH None 20 40 32.7 14.4 4.3 MBK200 22,000 RX<br />

Meter-Load Center Combination, 200amp, Lever Bypass with Alternate Energy Input<br />

(Over/Under Construction)<br />

MC2040S1200JLC 200<br />

60A / QP(H)<br />

MP-(H)T<br />

OH/UG<br />

HQ Lever<br />

Bypass<br />

20 40 40.1 14.4 5.2 MBK200 22,000<br />

Meter Mains – Non-EURSERC, 200amp with Alternate Energy Input (60A max)<br />

and Ring Type Cover (Side-by-Side Construction)<br />

MM0202S1200H 200<br />

QP, QPH &<br />

others<br />

OH/UG None 2 2 19.7 21.3 5.2<br />

Meter Mains – Non-EURSERC, 200amp with Alternate Energy Input (60A max)<br />

and Ringless Type Cover (Side-by-Side Construction)<br />

MM0202S1200RHJ<br />

MM0202S1200RJB<br />

200<br />

QP, QPH &<br />

others<br />

OH/UG<br />

None<br />

Horn<br />

2 2 19.7 21.3 5.2<br />

QN, QP &<br />

others<br />

QN, QP &<br />

others<br />

22,000<br />

22,000<br />

Hub<br />

Provision<br />

RX-top,<br />

HC-bot<br />

RX-top,<br />

HC-bot<br />

RX-top,<br />

HC-bot<br />

RX-top,<br />

HC-bot<br />

RX-top,<br />

HC-bot<br />

5th<br />

Jaw<br />

EMC5J<br />

EMC5J<br />

EC659-<br />

0121<br />

Installed<br />

EMC5J<br />

EMC5J<br />

Cover<br />

Type<br />

Ring<br />

Ring<br />

Ring<br />

Ring<br />

Ringless<br />

Ringless<br />

a Semi flush device.<br />

b Feed thru lugs included.<br />

2-44<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


EUSERC Meter Load Center Combinations<br />

EUSERC Meter Load Center Combinations<br />

Meter Mains<br />

Meter Load Center Combinations<br />

Meter Mains<br />

Meter Load Center Meter Combinations<br />

Mains<br />

Meter Centers<br />

Side-By-Side<br />

Over-Under 14” Side-By-Side 14”<br />

SOLAR Ready, Meter-Load Center Combination, 1-Phase, 3-Wire 120/240V AC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Side-By-Side<br />

Over-Under<br />

Over-Under<br />

14” Side-By-Side 14”<br />

Side-By-Side Full Combo Load Center<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Side-By-Side Over-Under Full Load Center Combo Side-By-Side<br />

Over-Under<br />

Side-By-Side Over-Under 400A<br />

Side-By-Side 400A<br />

Side-By-Side<br />

Ringless<br />

Side-<br />

n UL listed<br />

n For overhead and underground feed applications<br />

n 22,000 AIC Rated<br />

n Surface and semi-flush units available<br />

n Suitable for use only as service entrance equipment<br />

MC3042S1400FCS<br />

n Ring and Ringless type EUSERC meter Meter covers<br />

Mains<br />

EUSERC Meter Mains<br />

n Contact local utility to confirm meter socket approval prior<br />

to installation<br />

n Dedicated 200A auxiliary input provision for field<br />

installation of up to a 200A PV breaker<br />

EUSERC<br />

Side-By-Side<br />

EUSERC<br />

Side-By-Side 400A<br />

MC3042S1400FCS<br />

Side-By-Side<br />

Side-By-Side 400A<br />

EUSERC Meter Load Center Combinations<br />

EUSERC Meter Load Center Combinations<br />

EUSERC<br />

EUSERC<br />

EUSERC Meter Mains<br />

EUSERC<br />

Side-By-Side<br />

2 METER<br />

CENTERS<br />

Sid<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

EUSERC<br />

EUSERC<br />

Side-By-Side Full Load Center<br />

EUSERC Meter Load Cen<br />

EUSERC<br />

Side-By-Side 400A<br />

Over-Under 14” Side-By-Side 14”<br />

Side-By-Side Full Load Center<br />

Side-By-Side 400A<br />

EUSERC<br />

Over-Under 14”<br />

Side-By-S<br />

Catalog Number<br />

Amp<br />

Rating<br />

(Cont.)<br />

Aux.Input<br />

Max./<br />

Breaker<br />

Type<br />

Utility<br />

Incoming<br />

Bypass<br />

Type<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits<br />

Dimensions<br />

(inches)<br />

H W D<br />

Main<br />

Breaker<br />

Short<br />

Circuit<br />

Rating<br />

Hub<br />

Provision<br />

Meter-Load Center Combination, 400amp, Up to 200amp Alternate Energy Input, Lever Bypass<br />

MC3042S1400SCL<br />

200A /<br />

39.6 39.3 7.5<br />

320<br />

OH/UG Lever 30 42<br />

MC3042S1400FCL QN QP<br />

41.1 42.3 8.5<br />

EUSERC & CA Title 24 Compliant Meter-Load Center Combination, 400amp,<br />

Up to 200amp Alternate Energy Input, Manual Bypass<br />

MC3042S1400SCS<br />

200A /<br />

39.6 39.3 7.5<br />

320<br />

OH/UG Manual 30 42<br />

MC3042S1400FCS QN QP<br />

41.1 42.3 8.5<br />

MC3042S1400SDS<br />

200A /<br />

39.6 39.3 7.5<br />

320<br />

UG Manual 30 42<br />

MC3042S1400FDS QN QP<br />

41.1 42.3 8.5<br />

EUSERC & CA Title 24 Compliant Meter-Load Center Combination, 400amp,<br />

Up to 200amp Alternate Energy Input<br />

MC3042S1400SC<br />

200A<br />

39.6 39.3 7.5<br />

/<br />

320<br />

OH/UG None 30 42<br />

MC3042S1400FC QN QP<br />

41.1 42.3 8.5<br />

5th<br />

Jaw<br />

QN2200RH 22,000 HD —<br />

Cover<br />

Type<br />

QN2200RH 22,000 HD — Ring<br />

QN2200RH 22,000 HD — Ring<br />

QN2200RH 22,000 HD — Ring<br />

MC3042S1400SD<br />

39.6 39.3 7.5<br />

200A /<br />

320<br />

UG None 30 42<br />

QN QP<br />

MC3042S1400FD 41.1 42.3 8.5<br />

QN2200RH 22,000 HD — Ring<br />

a Flush rail kit available: Part Number ECFRK3.<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-45


EUSERC Meter Load Center Combinations<br />

EUSERC Meter Load Center Combinations<br />

Meter Centers<br />

Revised on 03/31/18<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC Compliant Side-by-Side Meter-Load Center Combination, 1-Phase, 3-Wire 120/240V AC<br />

Over-Under 14” Side-By-Side 14” Side-By-Side Full Load Center<br />

Over-Under 14” Side-By-Side 14” Side-By-Side Full Load Center<br />

S<br />

Side-By-<br />

2<br />

METER<br />

CENTERS<br />

n UL Listed<br />

n 100A-225A Continuous Rating as noted<br />

n Load center options include 8 space panel with feed<br />

through lugs and 12, 16, 24, 30 and 40 space panels<br />

n 22,000 AIC Rated<br />

n 5th Jaw available as noted<br />

n Factory installed semi flush mount option<br />

n Suitable for use only as service entrance equipment<br />

n Raised interior for ease of wiring<br />

n Raised neutral for ease of wiring<br />

n Convertable OH/UG<br />

n Contact local utility to confirm meter socket acceptance<br />

prior to installation<br />

n See end of section for knock out diagrams and wiring<br />

schematics<br />

n See page 2-42 for Solar Ready options<br />

MC0816B1200ESN<br />

MC1224B1125ESC<br />

EUSERC Compliant Meter-Load Center Combination, 100-125amp <br />

Utility<br />

Incoming<br />

Bypass<br />

Type<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits<br />

Dimensions<br />

Main<br />

Breaker<br />

Old Cat Number New Cat Number<br />

H W D<br />

5th Jaw<br />

MC1224B1100FEC MC1224B1100EFC<br />

22,000<br />

Flush RX (top) /<br />

OH/UG none 12 24 23.6 14.5 5 Q2100H<br />

HC (bot) EMC5J Ring<br />

MC1224B1100SEC MC1224B1100ESC Surface<br />

Short<br />

Circuit<br />

Rating<br />

Mounting<br />

Hub<br />

Provisions<br />

Cover<br />

Type<br />

MC1224B1125FEC MC1224B1125EFC<br />

Flush<br />

OH/UG none 12 24 23.6 14.5 5 Q2125H 22,000<br />

MC1224B1125SEC MC1224B1125ESC Surface<br />

RX (top) /<br />

HC (bot)<br />

EMC5J<br />

Ring<br />

EUSERC Compliant Meter-Load Center Combination, 200-225amp <br />

MC2442B1200FEC MC2040B1200EFC 7.0<br />

Flush<br />

OH/UG none 20 40 31.0 14.5 EQ9985 22,000<br />

MC2442B1200SEC MC2040B1200ESC 5.0 Surface<br />

RX (top) /<br />

HC (bot)<br />

EMC5J<br />

Ring<br />

MC2442B1225FEC MC2442B1225EFC 7.0<br />

Flush<br />

OH/UG none 24 42 35.0 14.5 EQ9986 22,000<br />

MC2442B1225SEC MC2442B1225ESC 5.0 Surface<br />

RX (top) /<br />

HC (bot)<br />

EMC5J<br />

Ring<br />

17.3 7.4<br />

Flush<br />

— MC2442B1200EFV<br />

OH/UG none 24 42 36.5<br />

EQ9986 22,000<br />

— MC2442B1200ESV 14.3 5.4 Surface<br />

MC0816B1200SCT MC0816B1200EST OH/UG none 8 16 29.75 14.5 5.0 EQ9985 22,000 Surface<br />

HC (bot) EMC5J Ring<br />

RX (top) /<br />

HC (bot)<br />

EMC5J<br />

Ring<br />

EUSERC Compliant Meter-Load Center Combination, 200 amp with 50amp Subfeed Provision <br />

MC0816B1200FCTM MC0816B1200EFN 7.0<br />

Flush<br />

OH/UG none 8 16 29.75 14.5 EQ9985 22,000<br />

MC0816B1200SCTM MC0816B1200ESN 5.0 Surface<br />

RX (top) /<br />

HC (bot)<br />

EMC5J<br />

Ring<br />

EUSERC Compliant Meter-Load Center Combination, 200amp, Full Load Center Width <br />

Catalog Number<br />

Utility<br />

Incoming<br />

Bypass<br />

Type<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits<br />

Dimensions<br />

H W D<br />

Main Breaker<br />

Short<br />

Circuit<br />

Rating<br />

Mounting<br />

Hub<br />

Provisions<br />

5th Jaw<br />

Cover<br />

Type<br />

MC3040B1200SECW<br />

30 40 32.3 21.0 5.2<br />

OH/UG<br />

none<br />

MC4040B1200SECW 40 40 32.3 21.0 5.2<br />

QN2200RH 22,000 Surface<br />

RX (top)/<br />

HC (bot)<br />

EMC5J<br />

Ring<br />

Feed thru lugs included.<br />

Devices are EUSERC compliant for field modification<br />

from factory UG to OH feed.<br />

Flush rail kits available.<br />

Flush rails adjustable for 2x4 walls only.<br />

Flush rails adjustable for up to 2x6 walls.<br />

Dimensional and other technical data is applicable<br />

for "New Catalog Numbers" ONLY.<br />

Old Catalog Numbers MC1632B1100FEC,<br />

MC1632B1100SEC, MC1632B1125FEC and<br />

MC0816B1200FCT are obsolete with no replacement.<br />

UL Listed for Siemens and Murray breakers.<br />

Bus Rated 225A.<br />

2-46<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


EUSERC Meter Load Center Combinations<br />

Meter Centers<br />

Revised on 03/31/18<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

EUSERC Compliant Side-by-Side Meter-Load Center Combination, 1-Phase, 3-Wire 120/240V AC<br />

Side-By-Side Full Load Center<br />

Side-By-Side 400A<br />

n UL Listed<br />

n 400A Max, 320A Continuous<br />

n Meter socket options include 320A (400A max),<br />

non-bypass and test block bypass<br />

n Load center options include 8 space panel and<br />

24-30 space panels<br />

n 22,000 AIC Rated<br />

MC3042B1400SC<br />

n Factory installed flush mount option<br />

n Surface mount devices accept field added flush rails<br />

n Suitable for use only as service entrance equipment<br />

n Contact local utility to confirm meter socket acceptance<br />

prior to installation<br />

n See end of section for knock out diagrams and wiring<br />

schematics<br />

MC0816B1400FD<br />

2 METER<br />

CENTERS<br />

Catalog Number<br />

Amp<br />

Rating<br />

(Cont.)<br />

Utility<br />

Incoming<br />

Bypass<br />

Type<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits<br />

Dimensions (inches)<br />

H W D<br />

Main<br />

Breaker<br />

Short<br />

Circuit<br />

Rating<br />

Mounting<br />

Hub<br />

Provision<br />

EUSERC Compliant Meter-Load Center Combination, 400amp max. with 200amp Subfeed Provision <br />

HD (top)<br />

HC (bot)<br />

MC0816B1400SC OH/UG<br />

33.2 6.4<br />

Surface<br />

—<br />

None 8 16 39.7<br />

22,000<br />

MC0816B1400FD UG 30.2 7.4 Factory<br />

Flush HC (bot) —<br />

installed<br />

MC3042B1400SC<br />

OH/UG<br />

33.2 6.4 QN2200RH<br />

HD (top) —<br />

& Field<br />

Surface<br />

MC3042B1400SD 320<br />

None 30 42 39.7 30.2 6.4 Installed<br />

22,000<br />

HC (bot)<br />

—<br />

UG<br />

MC3042B1400FD 30.2 7.4<br />

secondary<br />

Flush HC (bot) —<br />

QP(H) or<br />

MC4040B1200SC<br />

OH/UG<br />

42 33.2 6.5 QNR(H)<br />

None 40 40<br />

MC4040B1200SD UG 42 30.2 6.5<br />

22,000 Surface<br />

HD (top)<br />

HC (bot)<br />

EUSERC Compliant Meter-Load Center Combination, 400amp max. with 400amp Main Breaker <br />

MC2442B1400SD 320 UG None 24 42 39.7 30.2 6.6 Factory JXD6 22,000 Surface<br />

EUSERC Compliant Meter-Load Center Combination with Test Block Bypass,<br />

400amp max. with 200amp Subfeed Provision <br />

HD (top)<br />

HC (bot)<br />

MC0816B1400SCS Factory<br />

HD (top)<br />

OH/UG<br />

33.2 6.4 QN2200RH<br />

Surface<br />

—<br />

HC (bot)<br />

Test<br />

& Field<br />

8 16 39.7<br />

22,000<br />

Block<br />

secondary<br />

MC0816B1400FDS UG 30.2 7.4 QP(H) or<br />

QNR(H)<br />

Flush HC (bot) —<br />

MC2442B1400SDS 320 UG Manual 24 42 40.0 30.0 6.5 Factory JXD 22,000 Flush HD —<br />

MC3042B1400SCS<br />

OH/UG<br />

Test<br />

Block<br />

33.2 6.4<br />

Factory<br />

—<br />

QN2200RH<br />

HD (top)<br />

Surface<br />

& Field<br />

HC (bot)<br />

30.2 6.4 22,000<br />

—<br />

secondary<br />

QP(H) or<br />

QNR(H)<br />

MC3042B1400SDS<br />

30 42 39.7<br />

UG<br />

MC3042B1400FDS 30.2 7.4 Flush HC (bot) —<br />

Feed thru lugs included.<br />

Line side lugs not included.<br />

5th<br />

Jaw<br />

Cover<br />

Type<br />

Ring<br />

— Ring<br />

— Ring<br />

Ring<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-47


EUSERC Meter Load Center Com<br />

Meter Combinations<br />

EUSERC<br />

EUSERC<br />

EUSERC Compliant Over/Under Meter-Load Center Combination, 1-Phase, 3-Wire 120/240V AC<br />

Over-Under 14” Side-By-Side 14”<br />

2<br />

METER<br />

CENTERS<br />

General<br />

n UL Listed<br />

n Back to Back design – Meter section faces outdoor, load<br />

center faces indoor<br />

n 22,000 AIC rated<br />

n Suitable for use only as service entrance equipment<br />

n See end of section for dimensions and wiring diagrams<br />

Meter Section<br />

n Designed to meet EUSERC standards<br />

n Flush mounting enclosure, adjustable for 2x4 or 2x6 stud<br />

applications<br />

n Underground feed applications only<br />

n Pad locking provisions on all devices<br />

n Side hinge doors removable by backing out only one screw<br />

n Contact local utility to confirm meter socket approval prior<br />

to installation<br />

MC1212L1200SED<br />

MC3042B1200FED<br />

MC3042B1225FED<br />

MC3042B1250FE2<br />

MC3042B1250FE2<br />

Load Center View<br />

Meter Main View<br />

Catalog Number<br />

Amp<br />

Rating<br />

(Cont.)<br />

Utility<br />

Incoming<br />

Bypass<br />

Type<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits<br />

Dimensions (inches)<br />

H W D<br />

Main<br />

Breaker<br />

Short<br />

Circuit<br />

Rating<br />

Mounting<br />

Hub<br />

Provision<br />

EUSERC Compliant Meter-Load Center Combination, 200-225amp (Over/Under Construction) <br />

MC1212L1200SED RX (top)<br />

Surface<br />

200 UG None 12 12 38.4 14.4 7.4 NA<br />

HC (bot)<br />

MC1212L1200FED Flush HC (bot)<br />

22,000<br />

RX (top)<br />

MC2040B1200SED<br />

Surface<br />

200 UG None 20 40 41.9 14.4 7.4 MBK200A<br />

HC (bot)<br />

MC2040B1200FED Flush HC (bot)<br />

RX (top)<br />

MC3042B1200SED<br />

Surface<br />

200<br />

MBK200A<br />

HC (bot)<br />

MC3042B1200FED Flush HC (bot)<br />

UG None 30 42 48.4 14.4 7.4<br />

22,000<br />

RX (top)<br />

MC3042B1225SED<br />

Surface<br />

225 MBK225A<br />

HC (bot)<br />

MC3042B1225FED Flush HC (bot)<br />

EUSERC Compliant Meter-Load Center Combination with Interior Load Center,<br />

250amp (Back-to-Back Construction) <br />

MC2442B1250FE2<br />

24<br />

—<br />

200 UG None<br />

42 47.4 14.4 7.8 QNH 22,000 Flush HC<br />

MC3042B1250FE2 30 —<br />

5th<br />

Jaw<br />

EMC5J<br />

Cover<br />

Type<br />

Ring<br />

Ring<br />

No main breaker provided. Accept QN or QP type 2 or<br />

4-pole breakers.<br />

Suitable for use as service entrance equipment when<br />

not more than six disconnecting means are provided<br />

and when not used as a lighting an appliance panel<br />

board.<br />

Load wires exit top only.<br />

Load wires exit top or back.<br />

Provisions for up to 50A secondary main breaker.<br />

2-48<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


EUSERC Commercial Metering<br />

Commercial Type BY Meter-Main Combinations<br />

Design/Performance Features<br />

n Outdoor/Indoor—one design for either<br />

installation.<br />

n Ring Type—meets requirements for<br />

various ring type locking provisions.<br />

n Test Block Bypass Installed—easy<br />

servicing without interruption.<br />

n Main Breaker Field Installed—adaptable<br />

to the job.<br />

n Main T-Fuse puller factory installed<br />

(less fuses)—adaptable to the job.<br />

n Contact local utility to confirm meter<br />

socket approval prior to installation<br />

Industry Specifications<br />

n EUSERC – SEC #300<br />

n 240V rated<br />

n 100A and 200A models<br />

n Up to 100,000 AIC when using fuses<br />

2 METER<br />

CENTERS<br />

Ring Type Commercial Meter-Disconnect Combinations with Test Block Bypass<br />

240V AC Max<br />

Dimensions (inches)<br />

Amps<br />

Cont.<br />

Duty<br />

Max<br />

AIC<br />

Tenant<br />

Main <br />

CB or<br />

Fuse<br />

Provision Service Jaws<br />

Catalog<br />

Number<br />

Service<br />

Feed Height Width Depth<br />

100<br />

65,000<br />

Circuit<br />

Breaker<br />

Provision<br />

100,000 T-Fuse<br />

Puller<br />

QP/<br />

QPH/<br />

HQP<br />

Class T<br />

300V<br />

1Phase-<br />

3 Wire<br />

3 Phase-<br />

4 Wire<br />

1 Phase-<br />

3 Wire<br />

3Phase-<br />

4 Wire<br />

KO<br />

Fig.<br />

Wire Range<br />

AL/CU<br />

4 MM0202L1100EY OH 37.0 12.5 4.9 BY-1 #6-2/0<br />

7 MM0303L3100EY OH 37.0 12.5 4.9 BY-1 #6-2/0<br />

4<br />

7<br />

MM0202F1100EY OH 37.0 12.5 4.9 BY-1 #6-2/0<br />

MM0202F1100CEY OH/UG 24.0 20.2 4.9 BY-3 #6-2/0<br />

MM0303F3100EY OH 37.0 12.5 4.9 BY-1 #6-2/0<br />

MM0303F3100CEY OH/UG 24.0 20.2 4.9 BY-3 #6-2/0<br />

Hub<br />

Provision<br />

RX<br />

RX<br />

200<br />

35,000<br />

Circuit<br />

Breaker<br />

Provision<br />

100,000 T-Fuse<br />

Puller<br />

QJ2/<br />

QJH2/<br />

QJ2H/<br />

HQJ2H<br />

Class T<br />

300V<br />

1 Phase-<br />

3 Wire<br />

3 Phase-<br />

4 Wire<br />

1 Phase-<br />

3 Wire<br />

3 Phase-<br />

4 Wire<br />

4<br />

7<br />

4<br />

7<br />

MM0202L1200EY OH 45.0 14.3 6.4 BY-2 #1/0-250 kcmil<br />

MM0202L1200CEY OH/UG 30.0 24.3 6.4 BY-4 #1/0-250 kcmil<br />

MM0303L3200EY OH 45.0 14.3 6.4 BY-2 #1/0-250 kcmil<br />

MM0303L3200CEY OH/UG 30.0 24.3 6.4 BY-4 #1/0-250 kcmil<br />

MM0202F1200EY OH 45.0 14.3 6.4 BY-2 #1/0-250 kcmil<br />

MM0202F1200CEY OH/UG 30.0 24.3 6.4 BY-4 #1/0-250 kcmil<br />

MM0303F3200EY OH 45.0 14.3 6.4 BY-2 #1/0-250 kcmil<br />

MM0303F3200CEY OH/UG 30.0 24.3 6.4 BY-4 #1/0-250 kcmil<br />

HC<br />

HC<br />

a Breaker/fuses not included.<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-49


EUSERC Commercial Metering<br />

Commercial Type BY Meter-Load Center Combinations<br />

MC1224B1100CEY<br />

MC2442F3200CEY<br />

METER<br />

CENTERS<br />

2<br />

Design/Performance Features<br />

n Outdoor/Indoor—one design for either installation.<br />

n Ring Type—meets requirements for various ring type<br />

locking provisions.<br />

n Test Block Bypass Installed—easy servicing without<br />

interruption.<br />

n Main Breakers Factory Installed.<br />

n Main T-Fuse Pullers Factory Installed (less fuses).<br />

n Compact wall-hung design reduces material and<br />

labor costs.<br />

n 240V rated<br />

n 100A and 200A models<br />

n Contact local utility to confirm meter socket approval prior<br />

to installation<br />

Ring Type Commercial Meter-Load Center Combinations with Test Block Bypass<br />

240 V AC Max.<br />

Amps<br />

Cont.<br />

Duty Main Type<br />

No. of<br />

Spaces<br />

Max.<br />

Circuits<br />

Service<br />

Catalog<br />

Number<br />

1 Phase—3 Wire, 4 Jaws, Factory Installed Main Breaker <br />

100 Q2100<br />

installed<br />

QN2200RH<br />

200<br />

installed<br />

AIC Rating Dimensions (inches) a<br />

STD. MAX<br />

Hub<br />

AIC AIC Height Width Depth Prov.<br />

Wire Range<br />

AL/CU<br />

10 20 OH MC1020B1100EY 10,000 65,000 36.0 12.5 4.9 RX #6-2/0 BY-7<br />

12 24 OH/UG MC1224B1100CEY 10,000 42,000 24.0 20.2 4.9 RX #6-2/0 BY-8<br />

24 40 OH/UG MC2440B1200CEY 10,000 22,000 30.0 25.8 6.4 HC #1/0-250 kcmil BY-9<br />

3 Phase—4 Wire, 7 Jaws, Factory Installed T-Fuse Puller c<br />

100 Class T 300V 18 30 OH/UG MC1830F3100CEY 100,000 100,000 26.0 24.3 4.9 RX #6-2/0 BY-10<br />

200 Provision 24 42 OHUG MC2442F3200CEY 100,000 100,000 42.0 27.3 6.4 HC #1/0-250 kcmil BY-9<br />

KO<br />

Fig.<br />

BY Combo Accessories<br />

Description<br />

Catalog<br />

Number<br />

Hubs<br />

Conduit Size<br />

1" EC38596<br />

1 1 ⁄4" EC38597<br />

1 1 ⁄2" EC38598<br />

2" EC38599<br />

2" ECHC200<br />

2 1 ⁄2" EC38600<br />

2 1 ⁄2" ECHC250<br />

3" ECHC300<br />

Closure<br />

EC38595<br />

Plates<br />

ECHC000<br />

Adapter Plates<br />

Bottom Only<br />

ECHCRXA<br />

Description<br />

Fifth Jaw<br />

100A<br />

200A<br />

Catalog<br />

Number<br />

UX001WL<br />

UX005B<br />

a See accessories above for available 5th jaws.<br />

b UL Listed to field change main breaker to higher AIC.<br />

c Fuses not included.<br />

2-50<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Meter Centers<br />

Electricenter Accessories<br />

Selection<br />

RX Type Hub<br />

EC5J<br />

SRSTD<br />

EMC5J<br />

SRSW<br />

2 METER<br />

CENTERS<br />

Interchangeable Hubs<br />

Conduit Size<br />

(Inches) Lbs. Catalog Number<br />

RX Type Hubs<br />

3<br />

⁄4 EC38594<br />

1 EC38596<br />

1 1 ⁄4 EC38597<br />

1 1 ⁄2 EC38598<br />

2 EC38599<br />

2 1 ⁄2 EC38600<br />

HD Type Hubs<br />

2 EC56854<br />

2 1 ⁄2 EC56855<br />

3 EC56856<br />

3 1 ⁄2 EC56857<br />

4 EC56858<br />

HC Type Hubs<br />

2 ECHC200<br />

2 1 ⁄2 ECHC250<br />

3 ECHC300<br />

Accessories and Closure Plates<br />

Adapter ECHCRXA<br />

Plate<br />

EC9747-1113 (HD to RX)<br />

Closure ECHC000<br />

Plates<br />

EC38595 (RX Type)<br />

EC56933S (HD Type)<br />

Sealing Rings<br />

Description<br />

Snap-on type, aluminum<br />

Screw type, aluminum<br />

Catalog Number<br />

SRSTD<br />

SRSW<br />

Grounding Bars (AI/Cu — except where noted)<br />

Grounding bars are for use where grounding of electrical outlets<br />

and devices is by means of conductors. Each bar is equipped with<br />

large connectors rated for one #14-1/0 or, two or three #14-10 Cu/<br />

AI and small connectors rated for one #14-6 or, two #14-12 Cu/AI.<br />

(May be restricted by wire bending space.)<br />

Number of Connectors<br />

Length Total Large Small Catalog Number<br />

1 5 ⁄8 4 0 4 ECLX068M<br />

2 5 ⁄16 7 2 5 ECLX069M<br />

3 1 ⁄2 11 3 8 ECLX071M<br />

4 5 ⁄8 15 4 11 ECLX072M<br />

5 3 ⁄4 19 5 14 ECLX073M<br />

7 23 6 17 ECLX074M<br />

8 1 ⁄8 27 7 20 ECLX075M<br />

Miscellaneous Accessories<br />

Description<br />

Catalog Number<br />

Plastic Meter Opening Cover<br />

ECPP<br />

Plastic Meter Cover Ringless<br />

ECCP3<br />

NEMA Stud Mechanical Lugs a<br />

(2) #6-350 kcmil UK350TA<br />

(1) #2-600 kcmil Al/Cu UK600TA<br />

(2) #500-1000 kcmil Al/Cu UK1000TA<br />

5th Jaws <br />

EC5J<br />

EC5J2<br />

EC659-0121<br />

EMC5J<br />

H35815-2<br />

Neutral Feeder Lugs<br />

#2-1/0 ECLK1-2<br />

#4-2/0 ECLK2<br />

#1-350 kcmil ECLK3<br />

a Order one for each phase and neutral. For use on<br />

EUSERC 400A combinations.<br />

b See individual product pages for 5th jaw selection.<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-51


Meter Centers<br />

Meter Combinations Dimensions and Wiring Schematics<br />

15.0<br />

5.1<br />

RX<br />

METER<br />

CENTERS<br />

2<br />

33.5<br />

Q<br />

A<br />

S<br />

R<br />

S<br />

MC0408B1150RGA / MC0408B1200RGA<br />

n Product tables for above on page 2-39<br />

MC0408B1150T / MC0408B1200T /<br />

MC0408B1150RT / MC0408B1200RT<br />

n Product tables for above on pages 2-38 and 2-72<br />

MC0408B1400RLTM / MC0816B1350RLTM / MC0816B1400RLTM<br />

n Product tables for above on pages 2-41 and 2-73<br />

MC0606L1200R / MC0606L1200RA / MC0606L1200RJB<br />

n Product tables for above on pages 2-38 and 2-72<br />

17.0<br />

Knockout Code — Conduit Sizes<br />

5.2<br />

A = 1 ⁄2<br />

L = 3 ⁄8, 1 ⁄2, 3 ⁄4<br />

B = 1 ⁄2, 3 ⁄4<br />

M = 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

C = 1 ⁄2, 3 ⁄4, 1<br />

N = 1 ⁄4<br />

25.0<br />

D = 3 ⁄4, 1 1 ⁄4, 1 1 ⁄2<br />

E = 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

P = 2, 2 1 ⁄2, 3, 3 1 ⁄2, 4<br />

Q = 2 1 ⁄2, 3<br />

D<br />

F = 3 ⁄4, 1, 1 1 ⁄4<br />

G = 1, 1 1 ⁄4, 1 1 ⁄2<br />

R = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4<br />

S = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

K<br />

H<br />

C<br />

A<br />

H<br />

MC0606L1200RAD<br />

H = 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

J = 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

K = 1, 1 1 ⁄4, 2, 2 1 ⁄2, 3<br />

T = 1 1 ⁄2, 2, 2 1 ⁄2<br />

U = ¾, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

V = ¾, 1, 1 1 ⁄4, 1 1 ⁄2<br />

n Product tables for above on page 2-39<br />

2-52<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Meter Centers<br />

Meter Combinations Dimensions and Wiring Schematics<br />

15.0<br />

5.25<br />

12.03<br />

RX Type Hub<br />

5.1<br />

RX<br />

30.5<br />

29.06<br />

2 METER<br />

CENTERS<br />

K<br />

S<br />

S<br />

E<br />

E<br />

A<br />

R<br />

M<br />

M<br />

M<br />

MC0606L1200RGA<br />

n Product tables for above on page 2-39<br />

A N<br />

MC0606L1200RN<br />

n Product tables for above on page 2-38<br />

15.0<br />

5.1<br />

RX<br />

35.5<br />

Q<br />

A<br />

S<br />

R<br />

S<br />

MC0816B1150CT / MC0816B1200CT /<br />

MC0816B1150RCT / MC0816B1200RCT<br />

n Product tables for above on pages 2-38 and 2-72<br />

MC0816B1150RGA / MC0816B1200RGA<br />

n Product tables for above on page 2-39<br />

12.5<br />

5.3<br />

RX HUB<br />

Knockout Code — Conduit Sizes<br />

29.0<br />

K<br />

(2X) .31<br />

G<br />

MC0816B1150T / MC0816B1200T / MC0816B1200RT<br />

n Product tables for above on pages 2-38 and 2-73<br />

A = 1 ⁄2<br />

B = 1 ⁄2, 3 ⁄4<br />

C = 1 ⁄2, 3 ⁄4, 1<br />

D = 3 ⁄4, 1 1 ⁄4, 1 1 ⁄2<br />

E = 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

F = 3 ⁄4, 1, 1 1 ⁄4<br />

G = 1, 1 1 ⁄4, 1 1 ⁄2<br />

H = 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

J = 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

K = 1, 1 1 ⁄4, 2, 2 1 ⁄2, 3<br />

L = 3 ⁄8, 1 ⁄2, 3 ⁄4<br />

M = 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

N = 1 ⁄4<br />

P = 2, 2 1 ⁄2, 3, 3 1 ⁄2, 4<br />

Q = 2 1 ⁄2, 3<br />

R = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4<br />

S = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

T = 1 1 ⁄2, 2, 2 1 ⁄2<br />

U = ¾, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

V = ¾, 1, 1 1 ⁄4, 1 1 ⁄2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-53


Meter Centers<br />

MC0816B1200EFN<br />

Meter Combinations Dimensions and Wiring Schematics<br />

23.5<br />

C<br />

5.3<br />

(2X) RX HUB<br />

M<br />

A<br />

L<br />

2<br />

METER<br />

CENTERS<br />

21.0<br />

J<br />

H<br />

(3X) A<br />

MC0816B1200ESN/<br />

(3X) .31<br />

MC0816B1200EST<br />

(2X) G<br />

(4X) C<br />

MC0816B1150TH / MC0816B1200TH /<br />

MC0816B1150RTH / MC0816B1200RTH<br />

U with<br />

HC Hub<br />

provision<br />

A<br />

C<br />

L<br />

M<br />

MC0816B1200EFN<br />

n Product tables for above on pages 2-41 and 2-73<br />

n Product tables for above on pages 2-46 and 2-75<br />

14.3<br />

5.2<br />

RX<br />

32.1<br />

MC0816B1200ESN /<br />

MC0816B1200EST<br />

K<br />

H<br />

C<br />

A<br />

H<br />

MC0816B1200JLT<br />

n Product tables for above on page 2-46<br />

n Product tables for above on page 2-40<br />

17.0<br />

Knockout Code — Conduit Sizes<br />

5.2<br />

29.0<br />

A = 1 ⁄2<br />

B = 1 ⁄2, 3 ⁄4<br />

C = 1 ⁄2, 3 ⁄4, 1<br />

D = 3 ⁄4, 1 1 ⁄4, 1 1 ⁄2<br />

E = 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

L = 3 ⁄8, 1 ⁄2, 3 ⁄4<br />

M = 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

N = 1 ⁄4<br />

P = 2, 2 1 ⁄2, 3, 3 1 ⁄2, 4<br />

Q = 2 1 ⁄2, 3<br />

F = 3 ⁄4, 1, 1 1 ⁄4<br />

R = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4<br />

G = 1, 1 1 ⁄4, 1 1 ⁄2<br />

S = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

K<br />

H<br />

C<br />

A<br />

H<br />

MC0816B1200RTD<br />

H = 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

J = 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

K = 1, 1 1 ⁄4, 2, 2 1 ⁄2, 3<br />

T = 1 1 ⁄2, 2, 2 1 ⁄2<br />

U = ¾, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

V = ¾, 1, 1 1 ⁄4, 1 1 ⁄2<br />

n Product tables for above on page 2-39<br />

2-54<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Meter Centers<br />

Meter Combinations Dimensions and Wiring Schematics<br />

2 METER<br />

CENTERS<br />

n Product tables for above on pages 2-47 and 2-76 n Product tables for above on pages 2-47 and 2-76<br />

30.260<br />

Lever<br />

By-pass<br />

Service<br />

Disconnect<br />

(200A maximum)<br />

1<br />

Service<br />

Disconnect<br />

(200A maximum)<br />

22<br />

39.555<br />

A N B<br />

Neutral<br />

21<br />

N1<br />

42<br />

Equipment<br />

Ground<br />

(2X) C<br />

(16X) A<br />

(2X) F<br />

H<br />

(11X) B<br />

MC0816B1400SDL / MM0404L1400SDL<br />

MC3042B1400SDL<br />

n Product tables for above on pages 2-36, 2-41 2-73 and 2-76<br />

Knockout Code — Conduit Sizes<br />

A = 1 ⁄2<br />

B = 1 ⁄2, 3 ⁄4<br />

C = 1 ⁄2, 3 ⁄4, 1<br />

D = 3 ⁄4, 1 1 ⁄4, 1 1 ⁄2<br />

E = 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

F = 3 ⁄4, 1, 1 1 ⁄4<br />

G = 1, 1 1 ⁄4, 1 1 ⁄2<br />

H = 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

J = 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

K = 1, 1 1 ⁄4, 2, 2 1 ⁄2, 3<br />

L = 3 ⁄8, 1 ⁄2, 3 ⁄4<br />

M = 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

N = 1 ⁄4<br />

P = 2, 2 1 ⁄2, 3, 3 1 ⁄2, 4<br />

Q = 2 1 ⁄2, 3<br />

R = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4<br />

S = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

T = 1 1 ⁄2, 2, 2 1 ⁄2<br />

U = ¾, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

V = ¾, 1, 1 1 ⁄4, 1 1 ⁄2<br />

n Product tables for above on pages 2-47 and 2-76<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-55


Meter Centers<br />

Meter Combinations Dimensions and Wiring Schematics<br />

14.5<br />

7.1<br />

RX<br />

METER<br />

CENTERS<br />

2<br />

40.7<br />

MC1020B1100F/<br />

(5x)L<br />

MC1020B1100S<br />

K M<br />

(4x)A<br />

C<br />

n Product tables for above on page 2-44<br />

MC0816S1200SCT (shown) /<br />

MC2442S1200SC<br />

MC1020B1100FZ/<br />

MC1020B1100SZ<br />

n Product tables for above on pages 2-47 and 2-76<br />

4.4<br />

B<br />

V<br />

C<br />

B<br />

A<br />

MC1020B1100F /<br />

MC1020B1100S<br />

V<br />

C<br />

B<br />

A<br />

MC1020B1100FZ/<br />

MC1020B1100SZ<br />

n Product tables for above on pages 2-38 and 2-73<br />

n Product tables for above on pages 2-38 and 2-73<br />

Knockout Code — Conduit Sizes<br />

MC1212L1200FED<br />

A = 1 ⁄2<br />

B = 1 ⁄2, 3 ⁄4<br />

C = 1 ⁄2, 3 ⁄4, 1<br />

D = 3 ⁄4, 1 1 ⁄4, 1 1 ⁄2<br />

E = 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

F = 3 ⁄4, 1, 1 1 ⁄4<br />

G = 1, 1 1 ⁄4, 1 1 ⁄2<br />

H = 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

J = 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

K = 1, 1 1 ⁄4, 2, 2 1 ⁄2, 3<br />

L = 3 ⁄8, 1 ⁄2, 3 ⁄4<br />

M = 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

N = 1 ⁄4<br />

P = 2, 2 1 ⁄2, 3, 3 1 ⁄2, 4<br />

Q = 2 1 ⁄2, 3<br />

R = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4<br />

S = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

T = 1 1 ⁄2, 2, 2 1 ⁄2<br />

U = ¾, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

V = ¾, 1, 1 1 ⁄4, 1 1 ⁄2<br />

n Product tables for above on page 2-48<br />

2-56<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Meter Centers<br />

MC1224B1100FC/MM1224B1100ESC<br />

MC1224B1125EFC/MC1224B1125ESC<br />

Meter Combinations Dimensions and Wiring Schematics<br />

2 METER<br />

CENTERS<br />

MC1212L1200SED<br />

n Product tables for above on pages 2-48 and 2-76<br />

n Product tables for above on pages 2-46 and 2-75<br />

MC1224B1100EFC /<br />

MM1224B1100ESC<br />

MC1224B1125EFC /<br />

MC1224B1125ESC<br />

14.3<br />

5.2<br />

RX<br />

RX Hub<br />

23.5<br />

5.3<br />

32.1<br />

34.0<br />

J H (3X) A<br />

C<br />

C<br />

K<br />

H<br />

C<br />

A<br />

H<br />

MC1224B1125JLC /<br />

MC1224B1200JLC (shown)<br />

(3X) .31<br />

(2X) G<br />

(4X) C<br />

MC2040B1150 / MC2040B1150R /<br />

MC2040B1200 / MC2040B1200R<br />

n Product tables for above on page 2-40<br />

n Product tables for above on pages 2-41 and 2-73<br />

14.3<br />

5.2<br />

RX<br />

Knockout Code — Conduit Sizes<br />

C<br />

C<br />

36.1<br />

K H H<br />

MC2040B1150JLC /<br />

MC2040B1200JLC (shown)<br />

C A<br />

n Product tables for above on page 2-40<br />

A = 1 ⁄2<br />

B = 1 ⁄2, 3 ⁄4<br />

C = 1 ⁄2, 3 ⁄4, 1<br />

D = 3 ⁄4, 1 1 ⁄4, 1 1 ⁄2<br />

E = 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

F = 3 ⁄4, 1, 1 1 ⁄4<br />

G = 1, 1 1 ⁄4, 1 1 ⁄2<br />

H = 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

J = 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

K = 1, 1 1 ⁄4, 2, 2 1 ⁄2, 3<br />

L = 3 ⁄8, 1 ⁄2, 3 ⁄4<br />

M = 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

N = 1 ⁄4<br />

P = 2, 2 1 ⁄2, 3, 3 1 ⁄2, 4<br />

Q = 2 1 ⁄2, 3<br />

R = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4<br />

S = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

T = 1 1 ⁄2, 2, 2 1 ⁄2<br />

U = ¾, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

V = ¾, 1, 1 1 ⁄4, 1 1 ⁄2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-57


MC2040B1200ESC<br />

Meter Centers<br />

Meter Combinations Dimensions and Wiring Schematics<br />

METER<br />

CENTERS<br />

2<br />

MC2040B1200F/<br />

MC2040B1200S<br />

n Product tables for above on page 2-38<br />

MC2040B1150RC / MC2040B1150RJBC /<br />

MC2040B1200RC / MC2040B1200RJBC<br />

U with<br />

HC Hub<br />

provision<br />

A<br />

L<br />

M<br />

MC2040B1200ESC<br />

C<br />

n Product tables for above on pages 2-46 and 2-75<br />

H with<br />

RX Hub<br />

provision<br />

B<br />

A<br />

C<br />

4.4<br />

MC2040B1200FZ/<br />

MC2040B1200SZ<br />

A<br />

C<br />

B<br />

MC2040B1200F /<br />

MC2040B1200S<br />

MC2040B1200FED<br />

n Product tables for above on pages 2-38 and 2-73<br />

n Product tables for above on pages 2-48 and 2-75<br />

B<br />

H with<br />

RX Hub<br />

provision<br />

A<br />

C<br />

4.4<br />

Knockout Code — Conduit Sizes<br />

A = 1 ⁄2<br />

L = 3 ⁄8, 1 ⁄2, 3 ⁄4<br />

B = 1 ⁄2, 3 ⁄4<br />

M = 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

C = 1 ⁄2, 3 ⁄4, 1<br />

N = 1 ⁄4<br />

D = 3 ⁄4, 1 1 ⁄4, 1 1 ⁄2<br />

P = 2, 2 1 ⁄2, 3, 3 1 ⁄2, 4<br />

E = 1, 1 1 ⁄4, 1 1 ⁄2, 2 Q = 2 1 ⁄2, 3<br />

F = 3 ⁄4, 1, 1 1 ⁄4<br />

R = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4<br />

G = 1, 1 1 ⁄4, 1 1 ⁄2<br />

S = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

C<br />

B<br />

A<br />

MC2040B1200FZ/<br />

MC2040B1200SZ<br />

H = 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

J = 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

K = 1, 1 1 ⁄4, 2, 2 1 ⁄2, 3<br />

T = 1 1 ⁄2, 2, 2 1 ⁄2<br />

U = ¾, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

V = ¾, 1, 1 1 ⁄4, 1 1 ⁄2<br />

n Product tables for above on pages 2-38 and 2-73<br />

2-58<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Meter Centers<br />

Meter Combinations Dimensions and Wiring Schematics<br />

14.4<br />

5.2<br />

RX<br />

40.1<br />

2 METER<br />

CENTERS<br />

n Product tables for above on pages 2-48 and 2-75<br />

MC2040B1200SED<br />

MC2442B1225EFC<br />

K H H<br />

C A<br />

MC2040S1200JLC<br />

n Product tables for above on page 2-44<br />

4.3<br />

14.4<br />

RX<br />

C<br />

M<br />

A<br />

L<br />

32.7<br />

H<br />

MC2442B1225ESC<br />

(8x)A<br />

(6x)B (2x)C<br />

n Product tables for above on page 2-44<br />

MC2040S1200SZ<br />

U with<br />

HC Hub<br />

provision<br />

A<br />

C<br />

L<br />

M<br />

n Product tables for above on pages 2-46 and 2-75<br />

MC2442B1225EFC<br />

Knockout Code — Conduit Sizes<br />

A = 1 ⁄2<br />

B = 1 ⁄2, 3 ⁄4<br />

C = 1 ⁄2, 3 ⁄4, 1<br />

D = 3 ⁄4, 1 1 ⁄4, 1 1 ⁄2<br />

E = 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

L = 3 ⁄8, 1 ⁄2, 3 ⁄4<br />

M = 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

N = 1 ⁄4<br />

P = 2, 2 1 ⁄2, 3, 3 1 ⁄2, 4<br />

Q = 2 1 ⁄2, 3<br />

H<br />

F = 3 ⁄4, 1, 1 1 ⁄4<br />

G = 1, 1 1 ⁄4, 1 1 ⁄2<br />

R = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4<br />

S = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

U with<br />

HC Hub<br />

provision<br />

A<br />

C<br />

L<br />

M<br />

MC2442B1225ESC<br />

H = 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

J = 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

K = 1, 1 1 ⁄4, 2, 2 1 ⁄2, 3<br />

T = 1 1 ⁄2, 2, 2 1 ⁄2<br />

U = ¾, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

V = ¾, 1, 1 1 ⁄4, 1 1 ⁄2<br />

n Product tables for above on pages 2-46 and 2-75<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-59


Meter Centers<br />

Meter Combinations Dimensions and Wiring Schematics<br />

30.260<br />

Service<br />

Disconnect<br />

2<br />

1<br />

22<br />

METER<br />

CENTERS<br />

39.555<br />

A N B<br />

Neutral<br />

21<br />

42<br />

N1<br />

Equipment<br />

Ground<br />

(2X) C (16X) A<br />

(2X) F<br />

MC2442B1250FE2<br />

H<br />

(11X) B<br />

MC2442B1400SD<br />

n Product tables for above on page 2-48<br />

n Product tables for above on page 2-47<br />

30.260<br />

14.5<br />

7.1<br />

Service<br />

Disconnect<br />

1<br />

22<br />

A N B<br />

39.555<br />

40.7<br />

Neutral<br />

21<br />

42<br />

N1<br />

Equipment<br />

Ground<br />

(2X) C (16X) A<br />

H<br />

(11X) B<br />

(2X) F<br />

MC2442B1400SDB<br />

K<br />

(4x)A<br />

C<br />

M<br />

(5x)L<br />

MC2442S1200FC<br />

n Product tables for above on page 2-41<br />

n Product tables for above on page 2-44<br />

RX HUB<br />

5.0<br />

20.9<br />

Knockout Code — Conduit Sizes<br />

32.3<br />

A = 1 ⁄2<br />

B = 1 ⁄2, 3 ⁄4<br />

C = 1 ⁄2, 3 ⁄4, 1<br />

D = 3 ⁄4, 1 1 ⁄4, 1 1 ⁄2<br />

E = 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

F = 3 ⁄4, 1, 1 1 ⁄4<br />

G = 1, 1 1 ⁄4, 1 1 ⁄2<br />

L = 3 ⁄8, 1 ⁄2, 3 ⁄4<br />

M = 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

N = 1 ⁄4<br />

P = 2, 2 1 ⁄2, 3, 3 1 ⁄2, 4<br />

Q = 2 1 ⁄2, 3<br />

R = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4<br />

S = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

K<br />

(2X) M<br />

(11X) A<br />

(2X) L<br />

C<br />

H = 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

J = 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

K = 1, 1 1 ⁄4, 2, 2 1 ⁄2, 3<br />

T = 1 1 ⁄2, 2, 2 1 ⁄2<br />

U = ¾, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

V = ¾, 1, 1 1 ⁄4, 1 1 ⁄2<br />

MC3040B1200SECW / MC4040B1200SECW<br />

n Product tables for above on pages 2-46 and 2-75<br />

2-60<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Meter Centers<br />

Meter Combinations Dimensions and Wiring Schematics<br />

21.0<br />

5.1<br />

RX<br />

35.7<br />

2 METER<br />

CENTERS<br />

K<br />

M<br />

M<br />

(2x)L<br />

(11x)A<br />

C<br />

MC3040S1200SC / MC4040S1200SC<br />

n Product tables for above on page 2-44<br />

MC3042B1200FED (shown) / MC3042B1225FED<br />

n Product tables for above on pages 2-48 and 2-75<br />

14.3<br />

5.2<br />

RX<br />

42.1<br />

C<br />

C<br />

K H H<br />

MC3042B1200JLC<br />

C A<br />

n Product tables for above on page 2-40<br />

MC3042B1200SED / MC3042B1225SED<br />

n Product tables for above on pages 2-48 and 2-75<br />

Knockout Code — Conduit Sizes<br />

MC3042B1250FE2<br />

A = 1 ⁄2<br />

B = 1 ⁄2, 3 ⁄4<br />

C = 1 ⁄2, 3 ⁄4, 1<br />

D = 3 ⁄4, 1 1 ⁄4, 1 1 ⁄2<br />

E = 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

F = 3 ⁄4, 1, 1 1 ⁄4<br />

G = 1, 1 1 ⁄4, 1 1 ⁄2<br />

H = 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

J = 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

K = 1, 1 1 ⁄4, 2, 2 1 ⁄2, 3<br />

L = 3 ⁄8, 1 ⁄2, 3 ⁄4<br />

M = 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

N = 1 ⁄4<br />

P = 2, 2 1 ⁄2, 3, 3 1 ⁄2, 4<br />

Q = 2 1 ⁄2, 3<br />

R = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4<br />

S = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

T = 1 1 ⁄2, 2, 2 1 ⁄2<br />

U = ¾, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

V = ¾, 1, 1 1 ⁄4, 1 1 ⁄2<br />

n Product tables for above on page 2-48<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-61


Meter Centers<br />

Meter Combinations Dimensions and Wiring Schematics<br />

30.260<br />

C<br />

(4X) B<br />

30.260<br />

C<br />

(4X) B<br />

(11X) A<br />

(2X) H<br />

(2X) H<br />

(11X) A<br />

Service<br />

Disconnect<br />

(200A maximum)<br />

Service<br />

Disconnect<br />

(200A maximum)<br />

2<br />

1<br />

Service<br />

Disconnect<br />

(200A maximum)<br />

22<br />

Test<br />

By-pass<br />

Test<br />

By-pass<br />

1<br />

Service<br />

Disconnect<br />

(200A maximum)<br />

22<br />

METER<br />

CENTERS<br />

39.555 A N B<br />

Neutral<br />

39.555<br />

A N B<br />

Neutral<br />

(2X) C<br />

(16X) A<br />

21<br />

N1<br />

42<br />

Equipment<br />

Ground<br />

(2X) C<br />

(16X) A<br />

N1<br />

21<br />

42<br />

Equipment<br />

Ground<br />

(2X) F<br />

(2X) F<br />

H<br />

(11X) B<br />

MC3042B1400FD<br />

H<br />

(11X) B<br />

MC3042B1400FDS<br />

n Product tables for above on pages 2-47 and 2-76<br />

n Product tables for above on pages 2-47 and 2-76<br />

33.260<br />

33.260<br />

Service<br />

Disconnect<br />

(200A maximum)<br />

Service<br />

Disconnect<br />

(200A maximum)<br />

1<br />

Service<br />

Disconnect<br />

(200A maximum)<br />

22<br />

Test<br />

By-pass<br />

Test<br />

By-pass<br />

1<br />

Service<br />

Disconnect<br />

(200A maximum)<br />

22<br />

A N B<br />

39.555 A N B<br />

39.555<br />

Neutral<br />

Neutral<br />

(2X) C<br />

(16X) A<br />

21<br />

N1<br />

42<br />

Equipment<br />

Ground<br />

(2X) C<br />

(16X) A<br />

21<br />

N1<br />

42<br />

Equipment<br />

Ground<br />

(2X) F<br />

(2X) F<br />

H<br />

(11X) B<br />

MC3042B1400SC<br />

H<br />

(11X) B<br />

MC3042B1400SCS<br />

n Product tables for above on pages 2-47 and 2-76<br />

n Product tables for above on pages 2-47 and 2-76<br />

30.260<br />

Knockout Code — Conduit Sizes<br />

39.555<br />

A N B<br />

Neutral<br />

1<br />

Service<br />

Disconnect<br />

(200A maximum)<br />

Service<br />

Disconnect<br />

(200A maximum)<br />

22<br />

A = 1 ⁄2<br />

B = 1 ⁄2, 3 ⁄4<br />

C = 1 ⁄2, 3 ⁄4, 1<br />

D = 3 ⁄4, 1 1 ⁄4, 1 1 ⁄2<br />

E = 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

F = 3 ⁄4, 1, 1 1 ⁄4<br />

L = 3 ⁄8, 1 ⁄2, 3 ⁄4<br />

M = 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

N = 1 ⁄4<br />

P = 2, 2 1 ⁄2, 3, 3 1 ⁄2, 4<br />

Q = 2 1 ⁄2, 3<br />

R = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4<br />

(2X) C (16X) A<br />

(2X) F<br />

H (11X) B<br />

21<br />

N1<br />

42<br />

MC3042B1400SD/<br />

MC3042B1400SDS<br />

Equipment<br />

Ground<br />

G = 1, 1 1 ⁄4, 1 1 ⁄2<br />

H = 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

J = 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

K = 1, 1 1 ⁄4, 2, 2 1 ⁄2, 3<br />

S = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

T = 1 1 ⁄2, 2, 2 1 ⁄2<br />

U = ¾, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

V = ¾, 1, 1 1 ⁄4, 1 1 ⁄2<br />

n Product tables for above on pages 2-47 and 2-76<br />

2-62<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Meter Centers<br />

MM0202B1100ESC<br />

Meter Combinations Dimensions and Wiring Schematics<br />

30.260<br />

Service<br />

Disconnect<br />

(200A maximum)<br />

39.555 A N B<br />

Neutral<br />

1<br />

Service<br />

Disconnect<br />

(200A maximum)<br />

22<br />

2 METER<br />

CENTERS<br />

21<br />

N1<br />

42<br />

Equipment<br />

Ground<br />

(2X) C (16X) A<br />

(2X) F<br />

H (11X) B<br />

n Product tables for above on pages 2-41 and 2-48<br />

MC3042B1400SDB<br />

U with<br />

A L<br />

M<br />

HC Hub<br />

provision<br />

MM0202B1100ESC<br />

C<br />

n Product tables for above on pages 2-42 and 2-74<br />

MM0202B1200ESC<br />

MM0202B1125RJB<br />

MM0202B1150 / MM0202B1150R / MM0202B1150RJB<br />

MM0202B1200 / MM0202B1200R / MM0202B1200RJB<br />

n Product tables for above on pages 2-36 and 2-71<br />

MM0202B1125RJBX / MM0202B1150RJBX / MM0202B1200RJBX<br />

n Product tables for above on page 2-36<br />

Knockout Code — Conduit Sizes<br />

U with<br />

HC Hub<br />

provision<br />

A<br />

C<br />

L<br />

n Product tables for above on pages 2-42 and 2-74<br />

M<br />

MM0202B1200ESC<br />

A = 1 ⁄2<br />

B = 1 ⁄2, 3 ⁄4<br />

C = 1 ⁄2, 3 ⁄4, 1<br />

D = 3 ⁄4, 1 1 ⁄4, 1 1 ⁄2<br />

E = 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

F = 3 ⁄4, 1, 1 1 ⁄4<br />

G = 1, 1 1 ⁄4, 1 1 ⁄2<br />

H = 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

J = 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

K = 1, 1 1 ⁄4, 2, 2 1 ⁄2, 3<br />

L = 3 ⁄8, 1 ⁄2, 3 ⁄4<br />

M = 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

N = 1 ⁄4<br />

P = 2, 2 1 ⁄2, 3, 3 1 ⁄2, 4<br />

Q = 2 1 ⁄2, 3<br />

R = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4<br />

S = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

T = 1 1 ⁄2, 2, 2 1 ⁄2<br />

U = ¾, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

V = ¾, 1, 1 1 ⁄4, 1 1 ⁄2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-63


Meter Centers<br />

MM0202L1125EFC/<br />

MM0202L1125ESC<br />

Meter Combinations Dimensions and Wiring Schematics<br />

RX Type Hub<br />

5.3<br />

21.1<br />

2<br />

METER<br />

CENTERS<br />

17.1<br />

C<br />

J<br />

H<br />

H<br />

MM0202L1200EFC<br />

A<br />

MM0202B1200JLX / MM0202L1200JLX<br />

n Product tables for above on page 2-36<br />

n Product tables for above on pages 2-42 and 2-74<br />

MM0202L1125EFC /<br />

MM0202L1125ESC<br />

n Product tables for above on pages 2-42 and 2-74<br />

MM0202L1200EFC<br />

F<br />

MM0202ML1100S / JC002AR / JC002CS<br />

n Product tables for above on pages 2-36 and 2-71<br />

Knockout Code — Conduit Sizes<br />

MM0202ML1125H / JC002CZ<br />

n Product tables for above on pages 2-36 and 2-71<br />

F<br />

A = 1 ⁄2<br />

B = 1 ⁄2, 3 ⁄4<br />

C = 1 ⁄2, 3 ⁄4, 1<br />

D = 3 ⁄4, 1 1 ⁄4, 1 1 ⁄2<br />

E = 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

F = 3 ⁄4, 1, 1 1 ⁄4<br />

G = 1, 1 1 ⁄4, 1 1 ⁄2<br />

H = 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

J = 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

K = 1, 1 1 ⁄4, 2, 2 1 ⁄2, 3<br />

L = 3 ⁄8, 1 ⁄2, 3 ⁄4<br />

M = 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

N = 1 ⁄4<br />

P = 2, 2 1 ⁄2, 3, 3 1 ⁄2, 4<br />

Q = 2 1 ⁄2, 3<br />

R = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4<br />

S = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

T = 1 1 ⁄2, 2, 2 1 ⁄2<br />

U = ¾, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

V = ¾, 1, 1 1 ⁄4, 1 1 ⁄2<br />

2-64<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


MM0202L1200ESC<br />

Meter Centers<br />

Meter Combinations Dimensions and Wiring Schematics<br />

RX<br />

H<br />

J A C T<br />

RX<br />

19.75<br />

J A C T<br />

2 METER<br />

CENTERS<br />

RX<br />

U with<br />

HC Hub<br />

provision<br />

A<br />

C<br />

n Product tables for above on pages 2-42 and 2-74<br />

30.260<br />

(11X) A<br />

(4X) B<br />

C<br />

L<br />

M<br />

MM0202L1200ESC<br />

J A C T<br />

n Product tables for above on page 2-44<br />

30.260<br />

(11X) A<br />

(4X) B<br />

C<br />

MM0202S1200H /<br />

MM0202S1200RHJ /<br />

MM0202S1200RJB (shown)<br />

(2X) H<br />

(2X) H<br />

Service<br />

Disconnect<br />

(200A maximum)<br />

Service<br />

Disconnect<br />

(200A maximum)<br />

Service<br />

Disconnect<br />

(200A maximum)<br />

Test<br />

By-pass<br />

Test<br />

By-pass<br />

Service<br />

Disconnect<br />

(200A maximum)<br />

39.555<br />

A N B<br />

Equipment<br />

Ground<br />

39.555<br />

A N B<br />

Equipment<br />

Ground<br />

N1<br />

Neutral<br />

N1<br />

Neutral<br />

B<br />

(2X) H<br />

MM0404L1400FD<br />

B<br />

(2X) H<br />

MM0404L1400FDS<br />

n Product tables for above on pages 2-42 and 2-74<br />

n Product tables for above on pages 2-42 and 2-74<br />

Knockout Code — Conduit Sizes<br />

MM0404L1400RLM<br />

n Product tables for above on pages 2-36 and 2-71<br />

A = 1 ⁄2<br />

B = 1 ⁄2, 3 ⁄4<br />

C = 1 ⁄2, 3 ⁄4, 1<br />

D = 3 ⁄4, 1 1 ⁄4, 1 1 ⁄2<br />

E = 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

F = 3 ⁄4, 1, 1 1 ⁄4<br />

G = 1, 1 1 ⁄4, 1 1 ⁄2<br />

H = 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

J = 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

K = 1, 1 1 ⁄4, 2, 2 1 ⁄2, 3<br />

L = 3 ⁄8, 1 ⁄2, 3 ⁄4<br />

M = 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

N = 1 ⁄4<br />

P = 2, 2 1 ⁄2, 3, 3 1 ⁄2, 4<br />

Q = 2 1 ⁄2, 3<br />

R = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4<br />

S = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

T = 1 1 ⁄2, 2, 2 1 ⁄2<br />

U = ¾, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

V = ¾, 1, 1 1 ⁄4, 1 1 ⁄2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-65


Meter Centers<br />

Meter Combinations Dimensions and Wiring Schematics<br />

33.260<br />

33.260<br />

Service<br />

Disconnect<br />

(200A maximum)<br />

Service<br />

Disconnect<br />

(200A maximum)<br />

2<br />

METER<br />

CENTERS<br />

Test<br />

By-pass<br />

Test<br />

By-pass<br />

39.555 A N B<br />

N1<br />

Equipment<br />

Ground<br />

Neutral<br />

Service<br />

Disconnect<br />

(200A maximum)<br />

39.555<br />

A N B<br />

N1<br />

Equipment<br />

Ground<br />

Neutral<br />

Service<br />

Disconnect<br />

(200A maximum)<br />

B<br />

(2X) H<br />

MM0404L1400SCS<br />

B<br />

(2X) H<br />

MM0404L1400SC<br />

n Product tables for above on pages 2-42 and 2-74<br />

n Product tables for above on pages 2-42 and 2-74<br />

17.2<br />

RX<br />

5.0<br />

21.8<br />

RX<br />

5.0<br />

19.8<br />

19.8<br />

C<br />

C<br />

J<br />

H<br />

H<br />

J<br />

H<br />

H<br />

C<br />

A<br />

C<br />

A<br />

MM0406L1200H / MM0406L1200RH / MM0406L1200RHJB<br />

n Product tables for above on pages 2-36 and 2-71<br />

MM0406L1200RGA<br />

n Product tables for above on page 2-36<br />

RX Hub<br />

6.9<br />

14.2<br />

Knockout Code — Conduit Sizes<br />

30.6<br />

A = 1 ⁄2<br />

B = 1 ⁄2, 3 ⁄4<br />

C = 1 ⁄2, 3 ⁄4, 1<br />

D = 3 ⁄4, 1 1 ⁄4, 1 1 ⁄2<br />

E = 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

F = 3 ⁄4, 1, 1 1 ⁄4<br />

G = 1, 1 1 ⁄4, 1 1 ⁄2<br />

L = 3 ⁄8, 1 ⁄2, 3 ⁄4<br />

M = 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2<br />

N = 1 ⁄4<br />

P = 2, 2 1 ⁄2, 3, 3 1 ⁄2, 4<br />

Q = 2 1 ⁄2, 3<br />

R = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4<br />

S = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

J<br />

(4X) A<br />

C<br />

(5X) L<br />

M<br />

MM0406L1200SEC<br />

H = 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

J = 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

K = 1, 1 1 ⁄4, 2, 2 1 ⁄2, 3<br />

T = 1 1 ⁄2, 2, 2 1 ⁄2<br />

U = ¾, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

V = ¾, 1, 1 1 ⁄4, 1 1 ⁄2<br />

n Product tables for above on pages 2-42 and 2-74<br />

2-66<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Meter Centers<br />

Meter Combinations Dimensions and Wiring Schematics<br />

12.2<br />

14.5<br />

4.5<br />

RX HUB<br />

5.3<br />

Z Interior<br />

19.5<br />

E<br />

34.0<br />

2 METER<br />

CENTERS<br />

(4X) A<br />

(4X) B<br />

(8X) C<br />

Z Interior<br />

.312 KO<br />

(2X) C<br />

D<br />

JA1020B1100S(Z) / JA1020B1100F(Z)<br />

n Product tables for above on page 2-73<br />

(2X) C<br />

(6X) B<br />

n Product tables for above on page 2-73<br />

JA2040B1200S(Z) / JA2040B1200F(Z)<br />

EUSERC Commercial Metering<br />

Type BY Wiring Diagrams<br />

Commercial All-In-Ones<br />

MC1020B1100EY<br />

MC1224B1100CEY<br />

MC2440B1200CEY<br />

MC1830F3100CEY<br />

MC2442F3200CEY<br />

n Product tables for above on page 2-48<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-67


EUSERC Commercial Metering<br />

Type BY Knockout Diagrams<br />

n Product tables for BY on page 2-47 and 2-48<br />

Figure BY-1<br />

Figure BY-2<br />

Figure BY-3<br />

Figure BY-4<br />

METER<br />

CENTERS<br />

2<br />

G<br />

A<br />

Figure BY-7<br />

Figure BY-8<br />

Figure BY-9<br />

Figure BY-10<br />

Knockout Code—Conduit Sizes<br />

= 1 ⁄4 S = 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

A = 1 ⁄2 T = 1 1 ⁄4<br />

B = 1 ⁄2, 3 ⁄4 U = 1 1 ⁄4, 1 1 ⁄2<br />

C = 1 ⁄2, 3 ⁄4, 1 V = 1 1 ⁄4, 1 1 ⁄2, 2<br />

D = 1 ⁄2, 1 W = 1 1 ⁄4, 2<br />

E = 1 ⁄2, 3 ⁄4, 1, 1 1 ⁄4 X = 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2<br />

F = 1 ⁄2, 1 1 ⁄4, 1 1 ⁄2 Y = 1 1 ⁄2, 2<br />

G = 3 ⁄4 Z = 1 1 ⁄2, 2, 2 1 ⁄2<br />

H = 3 ⁄4, 1 AA = 1 1 ⁄2, 2, 2 1 ⁄2, 3<br />

J = 3 ⁄4, 1, 1 1 ⁄4 BB = 1 1 ⁄2, 2, 2 1 ⁄2, 3, 3 1 ⁄2<br />

K = 3 ⁄4, 1 1 ⁄4 CC = 2, 2 1 ⁄2, 3, 3 1 ⁄2<br />

M = 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2 EE = 2, 2 1 ⁄2, 3<br />

N = 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2 FF = 2 1 ⁄2, 3<br />

P = 1, 1 1 ⁄4 GG = 2 1 ⁄2, 3, 3 1 ⁄2<br />

Q = 1, 1 1 ⁄4, 1 1 ⁄2 HH = 2 1 ⁄2, 3, 3 1 ⁄2, 4<br />

R = 1, 1 1 ⁄4, 1 1 ⁄2, 2 JJ = 3 1 ⁄2, 4<br />

LL = 3<br />

VV = 2<br />

2-68<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Combination Meter Sockets<br />

Catalog Number Logic<br />

New Style Combination Meter Sockets<br />

JA 30 40 B 1 200 S E C W<br />

Main Ampere<br />

Rating<br />

2 METER<br />

CENTERS<br />

Circuits<br />

(max. No. of circuits)<br />

Spaces<br />

(max. No. of 1" breakers)<br />

JC = Meter Main<br />

JA = Meter Load Center Combination<br />

L = Main Lug<br />

B = Main Breaker<br />

1 = 1 Phase<br />

3 = 3 Phase<br />

F/S = Flush / Surface Mounting<br />

R = Ringless (blank = ring type)<br />

J = 5th Jaw<br />

B = Horn Bypass<br />

E = EUSERC Approved<br />

D/C = UG Feed Only / OH/UG feed<br />

L = Lever Bypass Socket<br />

T = Feed Thru Lugs<br />

W = Wide Load Center Design<br />

M = Field Addable Sub Feed Main<br />

H = Double Hub Provision<br />

Z = OH Feed, Load out Bottom Only<br />

A = Aluminum Enclosure<br />

Special Suffixes:<br />

`CS = Comb. Feed with Test Block Bypass<br />

DS = UG only Feed with Test Block Bypass<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-69


Combination Meter Sockets<br />

Introduction<br />

Meter Mains<br />

Meter Load Center Combinations<br />

Meter Mains<br />

Meter Load Center Combinations<br />

Meter Side-By-Side Mains<br />

This section includes 4 product categories, which each include their own set of featured products:<br />

Meter Load Center Combinations<br />

Over-Under Combo<br />

Over-Under<br />

Side-B<br />

2<br />

METER<br />

CENTERS<br />

Meter Mains<br />

Murray Meter Mains are UL Listed and available from 100A<br />

to 400A services. These Meter Mains utilize a cost effective<br />

Side-By-Side<br />

construction that is preferable in non-EUSERC areas.<br />

ad Center Combinations<br />

bo<br />

Meter Mains<br />

Over-Under<br />

Side-By-Side<br />

EUSERC Meter Mains<br />

Murray EUSERC Meter Mains are UL Listed and available from<br />

100A to 400A services. These meter mains utilize designs that<br />

meet EUSERC EUSERC Meter Over-Under Mains requirements. Combo Two constructions are Side-By-Side available.<br />

Over-Under Construction – These Meter Murray Mains<br />

Side-By-Side Meter Load Center Construction Combinations – These Murray<br />

Meter Mains feature a classic over-under<br />

Meter Mains have a side-by-side construction<br />

construction. Available in 100A and 125A<br />

that is slightly larger in order to meet EUSERC<br />

versions.<br />

EUSERC Meter Mains<br />

requirements.<br />

Meter Load Center Combinations<br />

Side-By-Side Construction – These Meter<br />

EUSERC Meter Mains<br />

Side-By-Side<br />

Side-By-Side 400A 400A Construction – These<br />

Side-By-Side<br />

Mains utilize a cost effective side-by-side<br />

Murray Meter Mains have side-by-side<br />

construction. Meter Mains combine Side-By-Side a socket to<br />

construction that meets EUSERC design, and<br />

Over-Under Combo<br />

Over-Under<br />

the left and main Meter circuit Mains breaker section to the Meter Load Center<br />

provide<br />

Combinations<br />

400A service.<br />

right. The main breaker section includes 2 to 6<br />

circuits.<br />

EUSERC Meter Load Center Combinations<br />

Side-By-Side<br />

Side-By-Side 400A<br />

Meter Load Center Combinations EUSERC Meter Mains EUSERC Meter Load Center Combinations<br />

Murray Meter Load Center Combinations offer several different Murray Meter Load Center Combinations offer several<br />

configurations and include a meter socket section and a load different configurations to meet a variety of installer demands.<br />

Side-By-Side<br />

center section. Meter Mains<br />

Meter<br />

These Murray combos feature a cost EUSERC Load<br />

effective Meter Center Load Combinations<br />

Center These Combinations<br />

Over-Under Combo Murray combos Over-Under feature designs Side-By-Side that meet EUSERC<br />

construction EUSERC that Meter is Mains preferable in non-EUSERC areas.<br />

requirements.<br />

EUSERC Meter Load Center Combinations<br />

Meter Load Center Combinations<br />

Over-Under Combination Construction –<br />

These Murray Meter Load Center Combinations<br />

Over-Under 14” Side-By-Side Over-Under 14” Between Side-By-Side the Full Load Studs CenterConstruction<br />

– These Combos have a full width load center<br />

Side-By-Side<br />

Side-By-Side 400A<br />

feature a over-under configuration EUSERC Meter with Mainsa unique<br />

section above, and a meter socket section<br />

trough allowing service from either overhead or<br />

below, in a 14.3" wide configuration that allows<br />

Side-By-Side<br />

underground to the device.<br />

flush mounting between typical 16" on center<br />

ad Center Combinations<br />

Over-Under Combo<br />

Over-Under<br />

Side-By-Side<br />

Side-By-Side<br />

Side-By-Side 400A<br />

stud construction. Surface mounting options<br />

Over-Under 14” Side-By-Side 14” Side-By-Side Full Load Center Side-By-Side 400A<br />

Over-Under Construction – These Murray EUSERC Meter Load Center Combinations available.<br />

Over-Under Combo<br />

Over-Under<br />

Side-By-Side<br />

Meter Load Center Combinations feature a<br />

Over-Under 14” Side-By-Side 14” Side-By-Side Full Load Center<br />

classic over-under construction.<br />

Side-By-Side Between the Studs Construction<br />

ons<br />

EUSERC Meter Mains<br />

– These combos have a half width load center<br />

Side-By-Side<br />

Side-By-Side 400A<br />

EUSERC Meter Load Center Combinations<br />

Side-By-Side Construction – These Murray<br />

section to the right and a meter socket section<br />

Meter Load Center Combinations have a side-byside<br />

configuration.<br />

allows flush mounting between typical 16" on<br />

to the left, in a 14.2" wide configuration that<br />

mbo<br />

Over-Under<br />

Side-By-Side<br />

Load Center Side-By-Side 400A<br />

center stud construction. Surface mounting<br />

EUSERC Meter Load Center Combinations options available.<br />

der<br />

EUSERC<br />

-By-Side 400A<br />

EUSERC<br />

EUSERC<br />

Side-By-Side<br />

EUSERC<br />

EUSERC<br />

Side-By-Side<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

EUSERC<br />

Over-Under Combo<br />

EUSERC<br />

EUSERC<br />

Side-By-Side Full Load Center<br />

EUSERC<br />

EUSERC<br />

Side-By-Side 400A<br />

EUSERC Meter Load Center Combinations<br />

Side-By-Side<br />

Over-Under<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Side-By-Side<br />

EUSERC<br />

Side-By-Side 400A<br />

Side-By-Side 400A<br />

Side-By-Side<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Side-By-Side Full Load Center<br />

Over-Under<br />

Over-Under Combo<br />

EUSERC<br />

EUSERC<br />

Side-By-Side 400A<br />

Side-By-Side Full Load Center Construction –<br />

These Murray Meter Load Center Combinations<br />

have a full width load center section to the right,<br />

and a meter socket section to the left. The<br />

overall width make this combo best suited for<br />

surface mounting.<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Side-By-Side 400A<br />

Over-Under<br />

Side-By-Side<br />

EUSERC<br />

EUSERC<br />

Side-By-Side 400A<br />

Side<br />

er Combinations<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

EUSERC<br />

EUSERC<br />

Side-By-Side Full Load Center<br />

EUSERC<br />

Side-By-Side 400A<br />

Side-By-Side 400A Construction – These<br />

Murray Meter Mains have side-by-side<br />

construction that meets EUSERC design, and<br />

provide 400A service. Available with 16 to 42<br />

circuits.<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

Side-By-Side Full Load Center<br />

Side-By-Side 400A<br />

e 14”<br />

Side-By-Side Full Load Center Side-By-Side 400A<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

2-70<br />

SERC


Meter Mains<br />

Meter Mains<br />

Meter Load Center Combinations<br />

Meter Mains<br />

Meter Load Center Combinations<br />

Meter Mains, 100A-400A<br />

Side-By-Side<br />

Side-By-Side<br />

Over-Under Combo<br />

Over-Under<br />

Over-Under Combo<br />

Side-By-Side<br />

Over-Under<br />

Side-By-Side<br />

n UL listed<br />

n Pad locking provisions on all devices<br />

n Horn bypass and 5th jaw available as noted<br />

n Side hinged door with one screw removal where shown Side-By-Side<br />

n Suitable for use only as service entrance equipment<br />

n Contact local utility to confirm meter socket placement prior<br />

to installation<br />

n See end of section for 5th jaw and main breaker<br />

n See Section 2, pages 2-44 thru 2-46 for wiring diagrams and<br />

knockout details. For Murray devices, replace "MM" with<br />

"JC" details if JC number is not shown.<br />

Meter Load Center Combinations<br />

Meter Mains<br />

Figure 2<br />

Meter Load Center Combinations<br />

Meter Mains<br />

Figure 3<br />

EUSERC Meter Mains<br />

EUSERC Meter Load Center Combinations<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

EUSERC<br />

Side-By-Side 400A<br />

Meter Mains<br />

Side-By-Side<br />

EUSERC Meter Mains<br />

EUSERC<br />

Side-By-Side<br />

Side-By-Side 400A<br />

EUSERC Meter Load Center Combinations<br />

Meter Load Center Combinations<br />

Figure 4<br />

EUSERC<br />

Side-By-Side Full Load Center<br />

EUSERC Meter Mains<br />

EUSERC Meter Load Center Combinations<br />

EUSERC<br />

EUSERC<br />

Side-By-Side<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

EUSERC<br />

Side-By-Side 400A<br />

EUSERC<br />

EUSERC<br />

Side-By-Side 400A<br />

EUSERC<br />

Meter Load Center Combinations<br />

Figure 1<br />

Over-Under Combo<br />

Side-By-Side Full Load Center<br />

Meter Mains<br />

Over-Under<br />

Side-By-Side<br />

JC0202B1125RJB<br />

meter mains, side hinge door<br />

Figure 5<br />

EUSERC<br />

Side-By-Side 400A<br />

Meter Load Center Combinations<br />

2 METER<br />

CENTERS<br />

Over-Under Combo<br />

Side-By-Side<br />

Over-Under<br />

Side-By-Side<br />

Over-Under Combo<br />

Side-By-Side<br />

Over-Under<br />

Side-By-Side<br />

Over-Under Combo<br />

EUSERC<br />

EUSERC<br />

Over-Under Over-Under 14” Side-By-Side<br />

14”<br />

Side-By-Side<br />

EUSERC<br />

Side-By-Side Full Load Center<br />

EUSERC<br />

Over-Under Combo<br />

Side-By-Side 400A<br />

Over-Under<br />

Side-By-Side<br />

EUSERC Meter Mains<br />

s<br />

EUSERC Meter Mains<br />

EUSERC Meter Mains<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Side-By-Side<br />

Side-By-Side 400A<br />

Side-By-Side 400A<br />

enter Combinations<br />

Combinations<br />

Side-By-Side<br />

JC0406L1200RHJB<br />

200A meter main, 6 circuits<br />

Side-By-Side 400A<br />

EUSERC Meter Load Center Combinations<br />

Side-By-Side<br />

JC0404L1400RLM<br />

400A meter main, two field<br />

installed mains<br />

Side-By-Side 400A<br />

EUSERC Meter Load Center Combinations<br />

JC002CZ<br />

125A meter main<br />

EUSERC Meter Load Center Combinations<br />

EUSERC<br />

JC002CS<br />

meter main, OH feed only<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

Side-By-Side Full Load Center<br />

Side-By-Side 400A<br />

EUSERC<br />

Over-Under<br />

y-Side 14”<br />

EUSERC<br />

Side-By-Side<br />

Amps<br />

Max.<br />

Side-By-Side Full Load Center<br />

Side-By-Side Construction Meter Mains<br />

No. of<br />

Spaces<br />

EUSERC<br />

EUSERC<br />

Side-By-Side Over-Under 400A 14” Side-By-Side 14”<br />

EUSERC<br />

Max.<br />

Side-By-Side Full Load Center<br />

Circuits Cover Type Mounting Service<br />

EUSERC EUSERC<br />

EUSERC<br />

Side-By-Side Over-Under 400A 14” Side-By-Side 14”<br />

Bypass<br />

Type<br />

EUSERC<br />

Catalog<br />

Number<br />

Side-By-Side Full Load Center<br />

EUSERC<br />

Side-By-Side 400A<br />

Dimensions a<br />

Height Width Depth<br />

125 2 2 Ring Surface OH — JC002CZ b 14.1 14.1 4.6 4<br />

125 2 2 Ringless Surface OH/UG Horn JC0202B1125RJB c 17.0 16.0 5.0 1<br />

Ring<br />

— JC0202B1200 c<br />

200 2 2 Ringless Surface OH/UG — JC0202B1200R c<br />

17.0 16.0 5.0 1<br />

Ringless Horn JC0202B1200RJB c<br />

Ring<br />

— JC0406L1200H c<br />

200 4 6 Ringless Surface OH/UG — JC0406L1200RH c<br />

19.8 17.2 5.0 2<br />

Ringless Horn JC0406L1200RHJB c<br />

400 2 2 Ringless Surface OH/UG Lever JC0404L1400RLM c 29.0 27.0 6.0 3<br />

Figure<br />

Meter Load Center Combinations<br />

EUSERC<br />

Over-Under Side-By-Side Combo400A<br />

Over-Under<br />

Amps<br />

Max.<br />

Over-Under Construction Meter Mains<br />

Side-By-Side<br />

No. of<br />

Spaces<br />

Max.<br />

Circuits Cover Type Mounting Service<br />

Bypass<br />

Type<br />

Catalog<br />

Number<br />

Dimensions a<br />

Height Width Depth<br />

100 2 2 Ring Surface OH — JC002CS b 18.1 7.0 3.6 5<br />

125 2 2 Ring Surface OH — JC002AR b 22.1 7.0 3.6 5<br />

Figure<br />

0A<br />

inations<br />

a Dimensions shown are representative of outside box length,<br />

width, & depth and do not include allowances for mounting<br />

bumps, endwalls, covers, hubs or hardware protrusions.<br />

Dimensions are subject to change.<br />

b Not suitable for 5th jaw applications.<br />

c Closure plate included.<br />

Provisions for MP-T Main Breaker.<br />

EUSERC<br />

Product Category RESI<br />

EUSERC<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-71<br />

Side-By-Side Full Load Center<br />

Side-By-Side 400A


Meter Load Center Combinations<br />

Meter Mains<br />

Meter Mains<br />

Meter Load Meter Center Load Combinations<br />

Center Combinations<br />

Over-Under Construction Meter Load Center Combinations, 150A-200A<br />

Side-By-Side<br />

Side-By-Side<br />

Over-Under Over-Under<br />

Combo<br />

Combo<br />

Over-Under<br />

Over-Under<br />

Side-By-Side<br />

Side-By-Side<br />

EUSERC Meter Mains<br />

EUSERC Meter Mains<br />

2<br />

METER<br />

CENTERS<br />

n UL listed<br />

n Overhead and underground feed applications<br />

n Underground feed accomplished by use of<br />

removable gutter trough<br />

n Load wires bottom or back exit only<br />

n 22,000 AIC rated<br />

n Pad locking provisions on all devices<br />

n Side hinge doors removable by backing out<br />

only one screw<br />

n Suitable for use only as service entrance<br />

equipment<br />

n RX type hub provision on top end wall<br />

n HC type hub provision on bottom end<br />

Side-By-Side<br />

Side-By-Side<br />

wall<br />

n Field addable 5th Jaw (EC5J2)<br />

EUSERC Meter Load Center Combinations<br />

EUSERC Meter Load Center Combinations<br />

n Contact local utility to confirm meter<br />

socket placement prior to installation<br />

EUSERC<br />

Side-By-Side 400A<br />

Side-By-Side 400A<br />

n See end of section for 5th jaw and main<br />

breaker<br />

Over-Under 14” Side-By-Side 14”<br />

Side-By-Side Full Load Center<br />

Side-By-Side 400A<br />

Over-Under 14” Side-By-Side 14” Side-By-Side Full Load Center Side-By-Side 400A<br />

n See Section 2, pages 2-34 thru 2-42 for<br />

wiring diagrams and knockout details.<br />

For Murray devices, replace "MC" with<br />

"JA" details if JA number is not shown.<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Meter Mains<br />

Meter Load Center Combinations<br />

Meter Mains<br />

Meter Load Center Combinations<br />

Meter Mains<br />

Meter Load Center Meter Combinations Mains<br />

Meter Load Center Combinations<br />

Figure 1<br />

Figure 2<br />

Figure 3<br />

Figure 4<br />

Side-By-Side<br />

Over-Under Combo<br />

Over-Under<br />

Side-By-Side<br />

Side-By-Side<br />

Over-Under Combo<br />

Over-Under<br />

Side-By-Side<br />

Side-By-Side<br />

Over-Under Combo<br />

Side-By-Side<br />

Over-Under<br />

Side-By-Side<br />

Over-Under Combo<br />

Over-Under<br />

Side-By-Side<br />

EUSERC Meter Mains<br />

EUSERC Meter Mains<br />

EUSERC Meter Mains<br />

EUSERC Meter Mains<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Side-By-Side<br />

Side-By-Side 400A<br />

Side-By-Side<br />

Side-By-Side 400A<br />

Side-By-Side<br />

Side-By-Side 400A<br />

Side-By-Side<br />

Side-By-Side 400A<br />

EUSERC Meter Load Center Combinations<br />

JA0606L1200<br />

200A, main lug, 6 circuit<br />

EUSERC<br />

Meter Load Center Combinations<br />

Over-Under 14” Side-By-Side 14”<br />

Side-By-Side Full Load Center<br />

EUSERC<br />

EUSERC<br />

JA0408B1150T<br />

150A or 200A main breaker,<br />

four 1" spaces, feed thru lugs<br />

EUSERC<br />

Side-By-Side 400A<br />

EUSERC Meter Load Center Combinations<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

EUSERC<br />

Side-By-Side Full Load Center<br />

EUSERC Meter Load Center Combinations<br />

JA0816B1150CT<br />

150A or 200A main breaker,<br />

eight 1" spaces, feed thru lugs<br />

EUSERC<br />

Side-By-Side 400A<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

EUSERC<br />

Side-By-Side Full Load Center<br />

JA0816B1120RT<br />

OH feed only, feed thru lugs,<br />

trailer panel<br />

EUSERC Meter Load Center Combinations<br />

EUSERC<br />

EUSERC<br />

Side-By-Side 400A<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

Side-By-Side Full Load Center<br />

Side-By-Side 400A<br />

Meter Mains<br />

Over-Under Combo<br />

Amps<br />

Max.<br />

Over-Under Combination Construction Meter Load Center Combinations<br />

Over-Under<br />

No. of<br />

Spaces<br />

Side-By-Side<br />

150 4 8<br />

Max.<br />

Circuits Cover Type Mounting Service<br />

Ringless<br />

Bypass<br />

Type<br />

Catalog<br />

Number<br />

— JA0408B1150RT c 30.0<br />

Ring — JA0408B1150T c<br />

Dimensions<br />

Height Width Depth<br />

Figure<br />

2<br />

EUSERC<br />

150 8 16<br />

Ring — JA0816B1150CT c 32.0 3<br />

Ringless — JA0816B1150RCT c<br />

eter Load Center Combinations<br />

200 12 6<br />

27.0 1<br />

Ringless Surface OH/UG — JA0606L1200R abce<br />

14.0 5.0<br />

Ring — JA0606L1200 abce<br />

Ringless — JA0606L1200RA abcde<br />

e<br />

Side-By-Side 400A<br />

EUSERC<br />

” Side-By-Side 14”<br />

200 4 8<br />

EUSERC<br />

200 8 16<br />

EUSERC<br />

Side-By-Side Full Load Center Side-By-Side 400A<br />

Ringless — JA0408B1200RT c<br />

Ring — JA0408B1200T c<br />

30.0 2<br />

Ring — JA0816B1200CT c<br />

Ringless — JA0816B1200RCT c<br />

32.0 3<br />

Meter Load Center Combinations<br />

Over-Under Combo<br />

Over-Under<br />

Amps<br />

Max.<br />

Over-Under Construction Meter Load Center Combinations<br />

Side-By-Side<br />

No. of<br />

Spaces<br />

200 8 16<br />

Max.<br />

Circuits Cover Type Mounting Service<br />

Ringless<br />

Surface OH<br />

Bypass<br />

Type<br />

Catalog<br />

Number<br />

— JA0816B1200RT<br />

Ring — JA0816B1200T<br />

Dimensions<br />

Height Width Depth Figure<br />

29.0 12.0 5.2 4<br />

0A<br />

inations<br />

a No main breaker provided. Accept MD-T or MP-T type 2<br />

or 4-pole breakers.<br />

b Suitable for use as service entrance equipment when<br />

not more than six disconnecting means are provided<br />

and when not used as a lighting an appliance panel<br />

board.<br />

c Due to wire space restrictions on the trough side, the<br />

left side of the interior is limited to a 60A max branch.<br />

d Aluminum enclosure.<br />

e Suitable for use as service entrance equipment when<br />

not more than six disconnecting means are provided<br />

and when not used as a lighting and appliance panel<br />

branch circuit panel board.<br />

EUSERC<br />

2-72<br />

EUSERC<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI<br />

Side-By-Side Full Load Center<br />

Side-By-Side 400A


n UL listed<br />

n 22,000 AIC Rated<br />

n Pad locking provisions on all devices<br />

n Side hinge doors removable by backing out only one Side-By-Side screw<br />

n Suitable for use only as service entrance equipment<br />

n Contact local utility to confirm meter socket approval prior<br />

to installation<br />

n See end of section for 5th Meter jaw Mains and main breaker<br />

Meter Load Center Combinations<br />

n See Section 2, pages 2-36 thru 2-50 for wiring diagrams<br />

and knockout details. For Murray devices, replace "MC" with<br />

Meter "JA" Load details Center Combinations if JA number is not shown.<br />

Side-By-Side<br />

Figure 2<br />

Figure 3<br />

Meter Mains<br />

Meter Load Center Combinations<br />

Meter Load Center Combinations, 100A-400A<br />

Side-By-Side<br />

Meter Mains<br />

EUSERC Meter Mains<br />

EUSERC Meter Load Center Combinations<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Meter Load Center Combinations<br />

Side-By-Side<br />

Over-Under Combo<br />

Over-Under<br />

Side-By-Side<br />

Meter Mains<br />

Meter Load Center Combinations<br />

EUSERC Meter Mains<br />

Side-By-Side<br />

Over-Under Combo<br />

Over-Under<br />

Side-By-Side<br />

Over-Under Combo<br />

Over-Under<br />

Side-By-Side<br />

EUSERC Meter Load Center Combinations<br />

Side-By-Side 400A<br />

Over-Under 14” Side-By-Side EUSERC 14” Meter Side-By-Side Load Center Full Load Combinations<br />

Center Side-By-Side 400A<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Side-By-Side<br />

Side-By-Side 400A<br />

Figure 1<br />

EUSERC Meter Mains<br />

EUSERC<br />

EUSERC<br />

Side-By-Side<br />

Side-By-Side<br />

Side-By-Side 400A<br />

Over-Under Combo<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC Meter Mains<br />

EUSERC<br />

Side-By-Side<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

Over-Under Combo<br />

Over-Under<br />

Over-Under 14” Side-By-Side Meter 14” Mains Side-By-Side Full Load Center Meter Load Side-By-Side Center Combinations<br />

400A<br />

Meter Mains<br />

Meter Load Center Combinations<br />

EUSERC<br />

Meter Load Center Combinations<br />

Over-Under<br />

Side-By-Side Full Load Center Side-By-Side 400A<br />

JA0816B1200TH<br />

Side-By-Side 400A<br />

OH/UG feed, with feed thru lugs<br />

EUSERC Meter Load Center Combinations<br />

Figure 4<br />

Figure 5<br />

Side-By-Side<br />

2 METER<br />

CENTERS<br />

EUSERC Meter Mains<br />

Over-Under Combo<br />

Over-Under<br />

Side-By-Side<br />

EUSERC<br />

EUSERC<br />

Side-By-Side<br />

EUSERC<br />

Over-Under Combo<br />

EUSERC<br />

Over-Under<br />

EUSERC<br />

Side-By-Side<br />

Side-By-Side<br />

EUSERC<br />

Over-Under Combo<br />

Over-Under<br />

Side-By-Side<br />

Side-By-Side<br />

Side-By-Side 400A<br />

EUSERC Over-Under Meter Mains 14” Side-By-Side 14”<br />

Side-By-Side Full Load Center<br />

EUSERC Side-By-Side Meter 400A Mains<br />

ains<br />

EUSERC Meter Load Center Combinations<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Side-By-Side 400A<br />

ad Center Combinations<br />

EUSERC<br />

Side-By-Side 14”<br />

EUSERC<br />

JA0816B1400RLTM<br />

factory installed 200A main<br />

and provision for 2nd<br />

60A-200A main<br />

EUSERC<br />

Side-By-Side Full Load Center<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

JA3042B1400SDL<br />

Side-By-Side Full Load Center Side-By-Side 400A<br />

400A, factory installed 200A<br />

main and provision for 2nd<br />

60A-200A main<br />

Over-Under 14” Side-By-Side 14”<br />

Side-By-Side Construction Meter Load Center Combinations <br />

EUSERC<br />

EUSERC<br />

Side-By-Side<br />

EUSERC Meter Load Center Combinations<br />

EUSERC<br />

Side-By-Side 400A<br />

MC2040B1200S<br />

200A, OH feed only, 40 circuits<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

EUSERC<br />

Side-By-Side Full Load Center<br />

Amps No. of Max.<br />

Bypass Catalog<br />

Dimensions<br />

Max. Spaces Circuits Cover Type Mounting Service Type Number<br />

Height Width Depth Figure<br />

Ringless<br />

— JA0816B1150RTH<br />

150<br />

Side-By-Side 400A Ring — JA0816B1150TH<br />

8 16<br />

21.0<br />

Ringless — JA0816B1200RTH<br />

200<br />

Ring — JA0816B1200TH<br />

Surface OH/UG<br />

200 20 40 Ring — JA2040B1200 b 18.0<br />

22.9 5.0 1<br />

350 8 16<br />

JA0816B1350RLTM a<br />

400 4 8 Ringless<br />

Lever JA0408B1400RLTM a<br />

29.0 27.0 6.0 2<br />

400 8 16 JA0816B1400RLTM a<br />

Side-By-Side 400A Construction Meter Load Center Combinations<br />

Amps No. of Max.<br />

Bypass Catalog<br />

Dimensions<br />

Max. Spaces Circuits Cover Type Mounting Service Type Number<br />

Height Width Depth Figure<br />

400 30 42 Ring Surface UG Lever JA3042B1400SDL 40.0 30.0 6.5 3<br />

Over-Under Construction Meter Load Center Combinations <br />

Amps<br />

Max<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits<br />

100 10 20 Ring<br />

200 20 40 Ring<br />

Side-By-Side<br />

EUSERC Meter Load Center Combinations<br />

MC1020B1100S<br />

100A, OH feed only, 20 circuits<br />

EUSERC<br />

Side-By-Side 400A<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

Side-By-Side Full Load Center<br />

Side-By-Side 400A<br />

<br />

Cover<br />

Bypass<br />

New Catalog Dimensions<br />

Type Mounting Service Type Old Catalog Number Number<br />

H W D Figure<br />

Flush<br />

JA1020B1100F MC1020B1100F<br />

Surface JA1020B1100S MC1020B1100S<br />

OH none<br />

Flush — MC1020B1100FZ 19.4 12.1 4.4 4<br />

Surface — MC1020B1100SZ <br />

Flush<br />

JA2040B1200F MC2040B1200F<br />

5.1<br />

Surface JA2040B1200S MC2040B1200S 4.4<br />

OH none<br />

30.5 14.3<br />

Flush — MC2040B1200FZ 5.1<br />

5<br />

Surface — MC2040B1200SZ 4.4<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Side-By-Side 400A<br />

a Feed thru lugs included.<br />

b Side by side design for OH/UG applications.<br />

c Over/under design for OH applications.<br />

Semi-Flush mounting only.<br />

Z=Solid horizontal barrier. Load wires exit back or<br />

bottom only.<br />

Dimensional and other technical data is applicable for<br />

"New Catalog Numbers" ONLY.<br />

UL Listed for Siemens and Murray breakers.<br />

Old Catalog Numbers JA1020B1100SP and<br />

JA2040B1200SP are obsolete with no replacement.<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-73


EUSERC Meter Mains<br />

EUSERC Side-By-Side Construction Meter Mains, 125A-400A<br />

EUSERC Meter Load Center Combinations<br />

EUSERC Meter Mains<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Over-Under 14”<br />

Side-By-Side Side-By-Side 14”<br />

Side-By-Side 400A<br />

Side-By-Side Full Load Center<br />

EUSERC<br />

Side-By-Side 400A<br />

EUSERC Meter Load Center Combinations<br />

2<br />

METER<br />

CENTERS<br />

n UL listed<br />

n For overhead and underground feed applications<br />

n Designed to meet EUSERC standards<br />

n 22,000 AIC Rated<br />

n Pad locking provisions on all devices<br />

n Surface and semi-flush units available - semi flush rails<br />

are depth adjustable for 2x6 studs<br />

n Side hinge door removable by backing out only one screw<br />

n Load wiring may exit top or bottom<br />

n Suitable for use only as service entrance equipment<br />

n RX type hub provision on top endwall, HC type hub<br />

provision on bottom endwall<br />

n 5th jaw accessory available (EMC5J)<br />

n Ring type meter covers<br />

n Contact local utility to confirm meter socket approval prior<br />

to installation<br />

n See end of section for 5th jaw and main breaker<br />

n See Section 2, pages 2-36 thru 2-50 for wiring diagrams<br />

and knockout details. For Murray devices, replace "MM"<br />

with "JC" details if JC number is not shown.<br />

Figure 1<br />

MM0202B1100ESC<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

Figure 2<br />

EUSERC<br />

Side-By-Side Full Load Center<br />

JC0404L1400SC<br />

400A meter main<br />

EUSERC<br />

Side-By-Side 400A<br />

Side-By-Side Construction Meter Mains <br />

Amps No. of No. of Cover<br />

Old Catalog New Catalog Deminsions<br />

Max Spaces Circuits Type Mounting Service Bypass Type Number<br />

Number<br />

H W D<br />

125<br />

Flush<br />

JC0406L1125FEC MM0202L1125EFC<br />

2 2 Ring<br />

OH/UG none<br />

23.6 14.5 5<br />

125 Surface JC0406L1125SEC MM0202L1125ESC<br />

200<br />

Flush<br />

— MM0202L1200EFC<br />

7<br />

2 2 Ring<br />

OH/UG none<br />

28.6 14.5<br />

200 Surface JC0406L1200FEC MM0202L1200ESC 5<br />

100<br />

Surface<br />

JC0406L1200SEC MM0202B1100ESC 23.6<br />

2 2 Ring<br />

OH/UG none<br />

14.5 5<br />

200 Surface — MM0202B1200ESC 28.6<br />

Figure<br />

1<br />

Side-By-Side 400A Construction Meter Mains <br />

Amps No. of Max.<br />

Catalog<br />

Dimensions a<br />

Max. Spaces Circuits Mounting Service Number<br />

Height Width Depth<br />

400 4 2<br />

Surface OH/UG JC0404L1400SC d 33.2 6.4<br />

39.7<br />

Flush UG JC0404L1400FD d 30.2 7.4<br />

400 4 2<br />

Surface OH/UG JC0404L1400SCS cd 33.2 6.4<br />

39.7<br />

Flush UG JC0404L1400FDS cd 30.2 7.4<br />

Figure<br />

2<br />

2<br />

a Dimensions shown are representative of outside box<br />

length, width, and depth and do not include allowances<br />

for mounting bumps, endwalls, covers, hubs or hardware<br />

protrusions. Dimensions are subject to change.<br />

b Main breaker not included.<br />

c Test block bypass.<br />

d Main breaker: (2) Field QP(H) or QNR(H).<br />

No 5th Jaw available.<br />

Dimensional and other technical data is applicable<br />

for "New Catalog Numbers" ONLY.<br />

UL Listed for Siemens and Murray breakers.<br />

2-74<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


EUSERC Meter<br />

EUSERC<br />

Load<br />

Meter<br />

Center<br />

Load<br />

Combinations<br />

Side-By-Side<br />

Center Combinations<br />

EUSERC Meter Load Center Combinations<br />

Over-Under Combo<br />

Over-Under<br />

Side-By-Side<br />

Side-By-Side<br />

Over<br />

EUSERC Meter Load Center Combos<br />

EUSERC<br />

EUSERC Meter Mains<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC Meter Mains<br />

EUSERC Meter Load Center Combinations, 100A-225A<br />

Over-Under 14” Side-By-Side 14” Side-By-Side Full Load Center Side-By-Side 400A<br />

Over-Under 14” Side-By-Side 14” Side-By-Side Full Load Center Side-By-Side 400A<br />

Over-Under 14” Side-By-Side 14” Side-By-Side Full Load Center Side-By-Side 400A<br />

EUSERC<br />

EUSERC<br />

Side-By-Side<br />

Side-By-Side 400A<br />

Side-By-Side<br />

EUSERC<br />

EUSERC<br />

Side-By-Side 400A<br />

n UL listed<br />

n For overhead and underground feed applications<br />

n Designed to meet EUSERC standards<br />

n 22,000 AIC Rated<br />

n Pad locking provisions on all devices<br />

n Surface and semi-flush units available - semi flush rails<br />

are depth adjustable for 2x6 studs<br />

n Side hinge door removable by backing out only one screw<br />

n Load wiring may exit top or bottom<br />

n Suitable for use only as service entrance equipment<br />

n RX type hub provision on top endwall, HC type hub<br />

provision on bottom endwall<br />

n Ring type meter covers<br />

n Contact local utility to confirm meter socket approval prior<br />

to installation<br />

n 5th jaw accessory available<br />

n See end of section for 5th jaw and main breaker<br />

n See Section 2, pages 2-36 thru 2-50 for wiring diagrams<br />

and knockout details. For Murray devices, replace "MC"<br />

with "JA" details if JA number is not shown.<br />

Fig. 1<br />

JA1212L1200SED<br />

Fig. 3<br />

Meter Mains<br />

Side-By-Side<br />

EUSERC Meter Mains<br />

Side-By-Side<br />

EUSERC Meter Load Center Meter Load Combinations Center Combinations<br />

Meter Mains<br />

Over-Under Combo<br />

Over-Under 14” Side-By-Side 14”<br />

EUSERC Meter Load Center Combinations<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Side-By-Side 400A<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

EUSERC<br />

Fig. 2<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Over-Under<br />

Side-By-Side Full Load Center<br />

JA3042B1200FED<br />

Fig. 4<br />

Meter Mains<br />

Side-By-Side<br />

EUSERC<br />

Side-By-Side<br />

Side-By-Side<br />

Side-By-Side 400A<br />

Side-By-Side Full Load Center Side-By-Side 400AOver-Under 14” Side-By-Side 14”<br />

EUSERC Meter Mains<br />

EUSERC<br />

Side-By-Side<br />

EUSERC<br />

EUSERC Meter Mains<br />

Side-By-Side<br />

EUSERC Meter Load Meter Center Load Combination Cente<br />

EUSERC<br />

EUSERC<br />

Over-Under Combo<br />

Over-Under 14” Side-By-Side 14”<br />

EUSERC Meter Load Center Combinations<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Side-By-Side 400A<br />

EUSERC<br />

EUSERC<br />

2 METER<br />

CENTERS<br />

EUSERC<br />

Side-B<br />

Meter Side-By-Side Load Center 400A Combinations<br />

Over-Under Combo<br />

Over-Under<br />

Side-By-Side Full Load Center<br />

MC1224B1125EFC<br />

MC2040B1200ESC<br />

EUSERC Meter Load Center Combinations<br />

Over-Under Between the Studs Construction Meter Load Center Combinations<br />

Amps<br />

Max.<br />

Side-By-Side Full Load Center Construction Meter Load Center Combinations<br />

200<br />

No. of<br />

Spaces<br />

200 12 12<br />

200 20 40<br />

200<br />

225<br />

30 42<br />

Max.<br />

Circuits Mounting Service<br />

Flush<br />

Surface<br />

UG<br />

Surface<br />

Flush<br />

UG<br />

Surface<br />

Flush<br />

Surface<br />

UG<br />

Flush<br />

Catalog<br />

Dimensions a<br />

Number<br />

Height Width Depth Figure<br />

JA1212L1200FED a<br />

JA1212L1200SED a 38.4 14.4 7.4 1<br />

JA2040B1200SED<br />

JA2040B1200FED<br />

41.9 14.4 7.4 2<br />

JA3042B1200SED<br />

JA3042B1200FED<br />

JA3042B1225SED<br />

48.8 14.4 7.4 2<br />

JA3042B1225FED<br />

30<br />

JA3040B1200SECW<br />

40 Surface OH/UG<br />

32.3 21.0 5.2 5<br />

40 JA4040B1200SECW <br />

Fig. 5<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

JA4040B1200SECW<br />

EUSERC<br />

EUSERC<br />

Side-By-Side Full Load Center Side-By-Side 40<br />

Side-By-Side Between the Studs Construction Meter Load Center Combinations <br />

Amps<br />

Max<br />

No. of<br />

Spaces<br />

No. of<br />

Circuits<br />

100 12 24 Ring<br />

125 12 24 Ring<br />

200 20 40 Ring<br />

225 24 42 Ring<br />

200<br />

24 42 Ring<br />

8 16 Ring<br />

Cover<br />

Type Mounting Service<br />

Flush<br />

OH/UG<br />

Bypass<br />

Type<br />

Old Catalog<br />

Number<br />

JA1224B1100FEC<br />

New Catalog<br />

Number<br />

MC1224B1100EFC<br />

Dimensions<br />

H W D<br />

none<br />

Surface JA1224B1100SEC MC1224B1100ESC<br />

23.6 14.5 5 3<br />

Flush<br />

JA1224B1125FEC MC1224B1125EFC<br />

OH/UG none<br />

Surface JA1224B1125SEC MC1224B1125ESC<br />

Flush<br />

JA2442B1200FEC MC2040B1200EFC<br />

7<br />

OH/UG none<br />

31 14.5 4<br />

Surface JA2442B1200SEC MC2040B1200ESC 5<br />

Surface<br />

— MC2442B1225ESC<br />

5<br />

OH/UG none<br />

35 14.5<br />

Flush — MC2442B1225EFC 7<br />

Surface<br />

— MC2442B1200ESC<br />

5<br />

OH/UG none<br />

35 14.5<br />

Flush — MC2442B1200EFC 7<br />

Flush<br />

— MC0816B1200EFN<br />

7<br />

OH/UG none<br />

29.75 14.5<br />

Surface JA0816B1200SCTM MC0816B1200ESN 5<br />

Figure<br />

a Suitable for use as service entrance equipment when not<br />

more than six main disconnecting means are provided and<br />

when not used as a lighting and appliance panel board.<br />

FRK1 - Flush rail kit.<br />

Dimensional and other technical data is applicable for<br />

"New Catalog Numbers" ONLY.<br />

Old Catalog Numbers JA1632B1100FEC,<br />

JA1632B1100SEC and JA1632B1125FEC are obsolete<br />

with no replacement.<br />

UL Listed for Siemens and Murray breakers.<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-75


EUSERC Meter Load Center Combinations<br />

EUSERC Side-By-Side Construction Meter Load Center Combinations, 400A<br />

EUSERC Meter Mains<br />

EUSERC<br />

EUSERC<br />

Side-By-Side<br />

Side-By-Side 400A<br />

EUSERC Meter Load Center Combinations<br />

2<br />

METER<br />

CENTERS<br />

n UL Listed<br />

n 400A Max, 320A Continuous<br />

n Meter socket options include 320A (400A<br />

max) lever bypass, non-bypass, test block<br />

bypass, and bolt on<br />

n Load center options include a meter<br />

main, 8 space panel with feed through<br />

lugs, 30 space panels<br />

n 22,000 AIC Rated<br />

n Accepts HD Type Hubs<br />

Meter Mains<br />

n Factory installed flush mount option<br />

Meter Load Center Combinations<br />

n Surface mount devices accept field<br />

added flush rails<br />

n Suitable for use only as service<br />

entrance equipment<br />

n Contact local utility to confirm meter<br />

socket acceptance prior to installation<br />

n Designed to meet EUSERC<br />

n See Section 2, pages 2-36 thru 2-50<br />

for wiring diagrams and knockout<br />

details. For Murray<br />

Meter Mains<br />

Meter Load Center Combinations<br />

devices, replace "MC" with "JA" details<br />

if JA number is not shown.<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

EUSERC<br />

Side-By-Side Full Load Center<br />

EUSERC<br />

Side-By-Side 400A<br />

Side-By-Side<br />

Over-Under Combo<br />

Over-Under<br />

Side-By-Side<br />

Side-By-Side<br />

Over-Under Combo<br />

Over-Under<br />

Side-By-Side<br />

Flush Mount Front View<br />

Meter Mains<br />

Side-By-Side<br />

EUSERC Meter Mains<br />

EUSERC<br />

Side-By-Side<br />

Figure 1<br />

EUSERC<br />

Meter Load Center Combinations<br />

Side-By-Side<br />

EUSERC Meter Mains<br />

EUSERC Meter Load Center Combinations<br />

Over-Under 14” Side-By-Side 14”<br />

JA0816B1400SCS<br />

Side-By-Side 400A<br />

meter combo with feed thru lugs,<br />

factory installed 200A main and<br />

provision for 2nd<br />

EUSERC Meter Load Center Combinations<br />

Over-Under Combo<br />

Over-Under<br />

EUSERC<br />

EUSERC<br />

Side-By-Side 400A<br />

Side-By-Side<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Side-By-Side Full Load Center<br />

Figure 2<br />

EUSERC<br />

Side-By-Side 400A<br />

EUSERC Meter Mains<br />

Side-By-Side<br />

EUSERC Meter Load Center Combinations<br />

Over-Under 14” Side-By-Side 14”<br />

JA3042B1400SC<br />

400A meter combo, factory installed<br />

200A main and provision for 2nd<br />

EUSERC<br />

EUSERC<br />

Side-By-Side 400A<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Side-By-Side Full Load Center<br />

Accessories<br />

Description<br />

Catalog Number<br />

Flush Rail Kit for UG<br />

only devices<br />

ECFRK1<br />

Flush Rail Kit for OH/UG<br />

feed devices<br />

ECFRK2<br />

2" HD Type Hub EC56854<br />

2 1/2" HD Type Hub EC56855<br />

3" HD Type Hub EC56856<br />

3 1/2" HD Type Hub EC56857<br />

4" HD Type Hub EC56858<br />

HD Closure Plate<br />

EC56933S<br />

Snap on Sealing Ring SRSS<br />

Stainless Steel Screw<br />

Type Sealing Ring<br />

SRSW<br />

(2) #6-350 kcmil UK350TA<br />

(1) #2-600 kcmil UK600TA<br />

(2) 500-1000 kcmil UK1000TA<br />

EUSERC<br />

Side-By-Side 400A<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

Side-By-Side 400A Construction Meter Load Center Combinations<br />

EUSERC<br />

EUSERC<br />

Amps<br />

Side-By-Side Full Load Center<br />

No. of<br />

Side-By-Side 400A<br />

Max.<br />

Meter Catalog<br />

Dimensions<br />

Max. Spaces Circuits Mounting Service Socket Number<br />

Main Breaker<br />

Height Width Depth<br />

Surface OH/UG JA0816B1400SC<br />

33.2 6.4<br />

400 8 16<br />

Plug In Factory QN2200RH, Field QP(H), QNR(H) 39.7<br />

Flush UG JA0816B1400FD 30.2 7.4<br />

Surface OH/UG JA0816B1400SCS<br />

33.2 6.4<br />

400 8 16<br />

Test Blk Factory QN2200RH, Field QP(H), QNR(H) 39.7<br />

Flush UG JA0816B1400FDS 30.2 7.4<br />

Plug In JA3042B1400SD<br />

400 30 42 Surface UG Test Blk JA3042B1400SDS Factory QN2200RH, Field QP(H), QNR(H) 39.7 30.2 6.4<br />

Bolt In JA3042B1400SDB<br />

Flush UG<br />

JA3042B1400FD<br />

30.2 7.4<br />

400 30 42<br />

Plug In<br />

Factory QN2200RH, Field QP(H), QNR(H) 39.7<br />

Surface OH/UG JA3042B1400SC 33.2 6.4<br />

Flush UG<br />

JA3042B1400FDS<br />

30.2 7.4<br />

400 30 42<br />

Test Blk<br />

Factory QN2200RH, Field QP(H), QNR(H) 39.7<br />

Surface OH/UG JA3042B1400SCS 33.2 6.4<br />

5th Jaw available. Use H35815-2.<br />

2-76<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Combination Meter Sockets<br />

Electricenter Accessories<br />

RX Type Hub<br />

HS Type Hub<br />

Interchangeable Hubs<br />

Conduit Size<br />

(Inches) Lbs.<br />

RX Type Hubs<br />

Catalog<br />

Number<br />

3<br />

⁄4 EC38594<br />

1 EC38596<br />

1 1 ⁄4 EC38597<br />

1 1 ⁄2 EC38598<br />

2 EC38599<br />

2 1 ⁄2 EC38600<br />

HC Type Hubs<br />

2 ECHC200<br />

2 1 ⁄2 ECHC250<br />

3 ECHC300<br />

Accessories and Closure Plates<br />

Adapter Plate<br />

HD to RX<br />

Adapter Plate<br />

HC to RX<br />

Closure Plates<br />

EC9747-1113<br />

HCRXA<br />

ECHC000 (HC)<br />

ECHS000 (HS)<br />

ECHV000 (HV)<br />

EC38595 (RX)<br />

Miscellaneous Accessories<br />

EC5J-2<br />

Sealing Rings<br />

SX001M<br />

SX006M<br />

Grounding Bars (AI/Cu — except<br />

where noted)<br />

Grounding bars are for use where<br />

grounding of electrical outlets and devices<br />

is by means of conductors. Each bar<br />

is equipped with large connectors rated<br />

for one #14-1/0 or, two or three #14-10<br />

Cu/AI and small connectors rated for<br />

one #14-6 or, two #14-12 Cu/AI. (May be<br />

restricted by wire bending space.)<br />

Number of Connectors Catalog<br />

Length Total Large Small Number<br />

1 5 ⁄8 4 0 4 ECLX068M<br />

2 5 ⁄16 7 2 5 ECLX069M<br />

3 1 ⁄2 11 3 8 ECLX071M<br />

4 5 ⁄8 15 4 11 ECLX072M<br />

5 3 ⁄4 19 5 14 ECLX073M<br />

7 23 6 17 ECLX074M<br />

8 1 ⁄8 27 7 20 ECLX075M<br />

Description<br />

Snap-on type, aluminum<br />

Screw type, aluminum<br />

Catalog Number<br />

SRSTD<br />

SRSW<br />

Description<br />

Catalog Number<br />

Plastic Meter Opening Cover (JA, JC)<br />

ECPP<br />

Plastic Meter Cover Ringless (JB)<br />

ECCP3<br />

Fifth Jaw (for old style JA & JC units only)<br />

EC5J<br />

5th Jaw for new style JA & JC devices<br />

EMC5J / EC5J2<br />

5th Jaw for 400A @ 9:00 with shield (see chart) H35815-2<br />

NEMA Stud Mechanical Lugs for JB, JK and JL units a<br />

(2) #6-350 kcmil<br />

(1) #2-600 kcmil Al/Cu<br />

(2) #500-1000 kcmil Al/Cu<br />

UK350TA<br />

UK600TA<br />

UK1000TA<br />

Neutral Feeder Lugs<br />

#2-1/0<br />

#4-2/0<br />

#1-350 kcmil<br />

EMC5J<br />

ECLK1<br />

ECLK2<br />

ECLK3<br />

Catalog Number Main Breaker 5th Jaw<br />

JC0406L1200H<br />

Provision for EMC5J<br />

JC0406L1200RH<br />

(1) MD-T, MD-HT EMC5J<br />

JC0406L1200RHJB or (2) MP-T, MP-HT Included<br />

Provision for<br />

JC0404L1400RLM (2) MD-T(R), MD-HT(R), H35815-2<br />

MP-T, MP-HT<br />

JC0202B1125RJB MP2125KH Included<br />

JC0202B1200 MPD2200KH EMC5J<br />

JC0202B1200R MPD2200KH EMC5J<br />

JC0202B1200RJB MPD2200KH Included<br />

JA0408B1150T ME9683 EC5J2<br />

JA0408B1150RT ME9683 EC5J2<br />

JA0816B1150CT ME9683 EC5J2<br />

JA0816B1150RCT ME9683 EC5J2<br />

JA0606L1200 b EC5J2<br />

JA0606L1200R b EC5J2<br />

JA0606L1200RA ME9683 EC5J2<br />

JA0408B1200T ME9683 EC5J2<br />

JA0408B1200RT ME9683 EC5J2<br />

JA0816B1200CT ME9683 EC5J2<br />

JA0816B1200RCT ME9683 EC5J2<br />

JA0816B1200RT QN2200RH NA<br />

JA0816B1200T QN2200RH NA<br />

JA0816B1150RTH MPD2150RH EMC5J<br />

JA0816B1150TH MPD2150RH EMC5J<br />

JA0816B1200RTH MPD2200RH EMC5J<br />

JA0816B1200TH MPD2200RH EMC5J<br />

JA2040B1200 MPD2200RH EMC5J<br />

JA0816B1350RLTM MPD2150RH EMC5J<br />

JA0408B1400RLTM MPD2200RH EMC5J<br />

JA0816B1400RLTM MPD2200RH EMC5J<br />

JA3042B1400SDL MPD2200RH EC35815<br />

JA1020B1100S(Z) MP2100KH EC5J2<br />

JA1020B1100F MP2100KH EC5J2<br />

JA2040B1200S(Z) EQ9685 EC5J2<br />

JA2040B1200F EQ9685 EC5J2<br />

JA1212L1200FED NA EC5J2<br />

JA1212L1200SED NA EC5J2<br />

JA2040B1200FED MBK200M EC5J2<br />

JA2040B1200SED MBK200M EC5J2<br />

JA3042B1200FED MBK200M EC5J2<br />

JA3042B1200SED MBK200M EC5J2<br />

JA3042B1225FED MBK225M EC5J2<br />

JA3042B1225SED MBK225M EC5J2<br />

JA1224B1100FEC MP2100KH EMC5J<br />

JA1224B1100SEC MP2100KH EMC5J<br />

JA1632B1100FEC MP2100KH EMC5J<br />

JA1632B1100SEC MP2100KH EMC5J<br />

JA1224B1125FEC MP2125KH EMC5J<br />

JA1224B1125SEC MP2125KH EMC5J<br />

JA1632B1125FEC MP2125KH EMC5J<br />

JC0406L1125FEC MP2125KH EMC5J<br />

JC0406L1125SEC MP2125KH EMC5J<br />

JA2442B1200FEC MEQ9985 EMC5J<br />

JA2442B1200SEC MEQ9985 EMC5J<br />

JC0406L1200FEC MEQ9985 EMC5J<br />

JC0406L1200SEC MEQ9985 EMC5J<br />

JA0816B1200SCTM<br />

EMC5J<br />

JA3040B1200SECW MPD2200RH EMC5J<br />

JA4040B1200SECW MPD2200RH EMC5J<br />

2 METER<br />

CENTERS<br />

a Order one for each phase and neutral.<br />

b No main breaker provided. Accept MD-T or MP-T type 2 or 4-pole breakers.<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-77


Group Metering: NYC Gangable Metering<br />

General Information<br />

2<br />

METER<br />

CENTERS<br />

Product Descriptions<br />

Murray New York City Apartment<br />

Metering is a versatile, unassembled<br />

modular metering product comprised of<br />

separate modules that may be assembled<br />

to produce a variety of configurations.<br />

Only those standard modules shown in<br />

this publication will be sold. Installation<br />

instructions are shipped with the<br />

product. The modules are:<br />

Meter Stacks<br />

Meter Stacks are available from 2 to 5<br />

meter positions, arranged vertically and<br />

pre-bussed on the line side. Each meter<br />

position is rated 100 amps continuous<br />

(125 amps maximum), 5 jaw, with<br />

the 5th jaw located at 9 o’clock and<br />

connected to the stack neutral bus.<br />

Indoor mounting only.<br />

Line Troughs<br />

Line troughs are indoor horizontal<br />

wireways that support the meter stacks<br />

and supply unmetered line power to<br />

meter stack bus. Line trough is available<br />

from 2 to 5 stack positions and may<br />

be ganged by means of couplers to<br />

accommodate 6 or more stacks. Phase<br />

blocks and line terminals are required<br />

to terminate line conductors and to<br />

provide means to field wire each<br />

stack. Trough end walls are ordered<br />

separately.<br />

Phase Blocks<br />

Phase blocks are required to terminate<br />

line conductors and provide terminals<br />

for field connection to each stack bus.<br />

Phase blocks are available with 3, 6 or<br />

12 take-off lugs.<br />

System Parameters<br />

n Mounting: Indoor only<br />

n Input: 208Y/120V AC, 3 Phase, 4 Wire or 120/240V AC,<br />

1 Phase, 3 Wire<br />

n Maximum line terminal- (2) 500 kcmil/phase<br />

n Output: 120Y/208V AC, 1 Phase, 3 wire or 120/240V AC,<br />

1 Phase, 3 Wire 100 Amps continuous/meter position (125<br />

amps maximum)<br />

n Meter Sockets: 5 jaw, with 5th jaw located at 9 o’clock and<br />

electrically connected to neutral bus<br />

n Tenant Circuit Breakers: Use Murray Type MP-T 2 pole plugon<br />

circuit breakers, (100 amps maximum)<br />

2-78<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Group Metering: NYC Gangable Metering<br />

General Information<br />

Getting Started<br />

Before ordering components, the following should be known:<br />

n Installation instructions are shipped with the product<br />

n Number of meter positions<br />

n Amp rating of each meter position<br />

n Voltage and phase of incoming line<br />

n Line conductor size and quantity<br />

n Vertical and horizontal space limitations, if any<br />

2 METER<br />

CENTERS<br />

Meter stacks are 10” wide and are 10” high for each meter position, or blank position.<br />

(A 3-high stack with no blank postions would be 10” wide and 30” high). When considering<br />

the overall height of an installation, you must add the height of the line trough (12”)<br />

and the breaker trough (16”) to the stack height.<br />

An installation of 3-high stacks would be 58” in overall height (30” + 12” + 16” = 58”).<br />

All meter stacks in the same meter bank must be the same height to allow the breaker<br />

trough to fit on top of the stacks.<br />

Line Terminal Kits<br />

Line terminals are available in kits of<br />

4 terminals each. The terminals are<br />

tang lugs which mount on threaded<br />

studs provided on the phase blocks.<br />

Terminals are available in 3 sizes:<br />

n (1) 350 kcmil<br />

n (1) 500 kcmil<br />

n (2) 500 kcmil maximum<br />

Breaker Troughs<br />

Breaker troughs are horizontal indoor<br />

wireways that contain provisions for<br />

plug-in circuit breakers used as tenant<br />

mains. The trough bolt to the top of<br />

the meter stacks. Field wiring connects<br />

each meter socket to a circuit breaker<br />

mounting block. Breaker troughs are<br />

available in 2 to 5 stack postitions and<br />

can be ganged to accommodate 6 or<br />

more stacks. Trough end walls are<br />

ordered separately.<br />

Circuit Breakers<br />

New York City Apartment Metering<br />

uses standard 2-pole plug-on circuit<br />

breakers, Murray Type MP-T, 100 amps<br />

maximum.<br />

End Wall Kits<br />

These kits contain 4 end walls; 2 end<br />

walls for the line trough and 2 end walls<br />

for the breaker trough.<br />

Coupler Kits<br />

These kits each contain 2 trough coupler<br />

straps; one for the line trough and<br />

one for the breaker trough. These couplers<br />

mount using the same mounting<br />

screw holes as the end walls.<br />

Line Trough Spacer Kits<br />

These kits may be used to increase<br />

wire bend space between the first<br />

phase block and line entrance end<br />

wall, if necessary. They connect to line<br />

troughs with a standard coupling kit.<br />

Trough end walls are ordered separately.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-79


Group Metering: NYC Gangable Metering<br />

Meter Stack Selection<br />

2<br />

Use Selection Chart #1 and Specification Chart #1<br />

Knowing the number of meter positions, and the height and width<br />

requirements, select quantity and catalog number of stacks from<br />

Selection Chart #1. The height dimension in this chart includes line<br />

and breaker troughs. For specs, refer to Specification Chart #1.<br />

METER<br />

CENTERS<br />

Specification Chart #1—Meter Stacks 300V AC max.,<br />

100 Amps/Position Continuous Duty, 1 or 3 Phase Network<br />

Meter<br />

Positions<br />

Height a<br />

(Inches)<br />

Catalog<br />

Number<br />

2 20 UVS210 #6-4/0<br />

2 30 UVS311B #6-4/0<br />

3 30 UVS310 #6-4/0<br />

3 40 UVS411B #6-4/0<br />

4 40 UVS410 #6-4/0<br />

4 50 UVS511B #6-4/0<br />

5 50 UVS510 #6-4/0<br />

Wire Range<br />

Line Terminals<br />

a All stacks are 10” wide.<br />

Selection Chart #1—Meter Bank Height and Width<br />

Meter Stack Combinations for Various Heights and Widths, by Number of Meter Positions<br />

No. of<br />

Meter<br />

Positions<br />

58” High 68” High 78” High<br />

Use this Quantity of: Width Use this Quantity of: Width Use this Quantity of:<br />

UVS310 UVS311B (Inches) UVS410 UVS411B (Inches) UVS510 UVS511B<br />

a Use (3) UVS310 instead of (3) UVS411B.<br />

b Use 3-high or 4-high stacks.<br />

Width<br />

(Inches)<br />

9 3 0 30 Not Practical a — 1 1 20<br />

10 2 2 40 1 2 30 2 0 20<br />

11 3 1 40 2 1 30 Not Possible b —<br />

12 4 0 40 3 0 30 Not Practical b —<br />

13 3 2 50 1 3 40 1 2 30<br />

14 4 1 50 2 2 40 2 1 30<br />

15 5 0 50 3 1 40 3 0 30<br />

16 4 2 60 4 0 40 Not Practical b —<br />

17 5 1 60 2 3 50 1 3 40<br />

18 6 0 60 3 2 50 2 2 40<br />

19 5 2 70 4 1 50 3 1 40<br />

20 6 1 70 5 0 50 4 0 40<br />

21 7 0 70 3 3 60 1 4 50<br />

22 6 2 80 4 2 60 2 3 50<br />

23 7 1 80 5 1 60 3 2 50<br />

24 8 0 80 6 1 60 4 1 50<br />

25 7 2 90 4 3 70 5 0 50<br />

26 8 1 90 5 2 70 2 4 60<br />

27 9 0 90 6 1 70 3 3 60<br />

28 8 2 100 7 0 70 4 2 60<br />

29 9 1 100 5 3 80 5 1 60<br />

30 10 0 100 6 2 80 6 0 60<br />

31 9 2 110 7 1 80 3 4 70<br />

32 10 1 110 8 0 80 4 3 70<br />

33 11 0 110 6 3 90 5 2 70<br />

34 10 2 120 7 2 90 6 1 70<br />

35 11 1 120 8 1 90 7 0 70<br />

36 12 0 120 9 0 90 4 4 80<br />

37 11 2 130 7 3 100 5 3 80<br />

38 12 1 130 8 2 100 6 2 80<br />

39 13 0 130 9 1 100 7 1 80<br />

40 12 2 140 10 0 100 8 0 80<br />

2-80<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Group Metering: NYC Gangable Metering<br />

Trough & Phase Block Selection<br />

Line Troughs<br />

(Use Selection Chart #2 and<br />

Specification Chart #2)<br />

Knowing the number of meter stacks,<br />

(not meter positions!) and the height<br />

and width requirements, select quantity<br />

and catalog number of stacks from<br />

Selection Chart #2. For specs, refer to<br />

Specification Chart #2<br />

Breaker Troughs<br />

(Use Selection Chart #2 and<br />

Specification Chart #3)<br />

Using the total number of meter<br />

stacks, (not meter positions!), select<br />

the quantity and catalog number of<br />

breaker troughs from Selection Chart #2<br />

and spec from Specification Chart #3.<br />

Use MP-T style breakers only. Breakers<br />

not included.<br />

Phase Blocks<br />

(Use Selection Chart #2 and<br />

Specification Chart #4)<br />

Using the number of meter stacks<br />

and the incoming power supply, use<br />

Selection Chart #2 to determine the<br />

quantity and catalog number of phase<br />

blocks for line and neutral termination.<br />

Spec these from Specification Chart #4.<br />

2 METER<br />

CENTERS<br />

Selection Chart #2—Line Trough, Breaker Trough and Phase Block Selection<br />

No. of<br />

Meter<br />

Stacks<br />

in Bank<br />

Line Trough Selection<br />

Left<br />

Trough<br />

Middle<br />

Trough<br />

Right<br />

Trough<br />

Breaker Trough Selection<br />

Left<br />

Trough<br />

Middle<br />

Trough<br />

Right<br />

Trough<br />

a Spacer ULT10SP is required if line conductors exceed #6 AWG.<br />

b Spacer ULT10SP is required if line conductors exceed #350 kcmil.<br />

c Requires (1) UCP1216 Coupler Kit. Kit provides coupling straps for both line and breaker troughs.<br />

d Requires (2) UCP1216 Coupler Kits. Kit provides coupling straps for both line and breaker troughs.<br />

Phase Block Section<br />

3 Phase, 4 Wire System 1 Phase, 3 Wire System<br />

Line<br />

Blocks<br />

Neutral<br />

Block<br />

Line<br />

Blocks<br />

Neutral<br />

Block<br />

3 ULT30a — — UBT30 — — (3) UPB3 (1) UPB3 (2) UPB3 (1) UPB3<br />

4 ULT40b — — UBT40 — — (3) UPB3 (1) UPB6 (2) UPB6 (1) UPB6<br />

5 ULT50 — — UBT50 — — (3) UPB6 (1) UPB6 (2) UPB6 (1) UPB6<br />

6 ULT30c — ULT30 UBT30c — UBT30 (3) UPB6 (1) UPB6 (2) UPB6 (1) UPB6<br />

7 ULT40c — ULT30 UBT40c — UBT30 (3) UPB6 (1) UPB12 (2) UPB12 (1) UPB12<br />

8 ULT40c — ULT40 UBT40c — UBT40 (3) UPB6 (1) UPB12 (2) UPB12 (1) UPB12<br />

9 ULT50c — ULT40 UBT50c — UBT40 (3) UPB6 (1) UPB12 (2) UPB12 (1) UPB12<br />

10 ULT50c — ULT50 UBT50c — UBT50 (3) UPB12 (1) UPB12 (2) UPB12 (1) UPB12<br />

11 ULT40d ULT40 ULT30 UBT40d UBT40 UBT30 (3) UPB12 (1) UPB12 (2) UPB12 (1) UPB12<br />

12 ULT40d ULT40 ULT40 UBT40d UBT40 UBT40 (3) UPB12 (1) UPB12 (2) UPB12 (1) UPB12<br />

Specification Chart #2—Line Troughs<br />

240V AC max. 1 Phase or 3 Phase<br />

Stack<br />

Positions<br />

Widtha<br />

(Inches)<br />

a Line troughs are 12” high.<br />

b Will not accommodate Phase Blocks.<br />

Catalog<br />

Number<br />

2 20 ULT20 b<br />

3 30 ULT30<br />

4 40 ULT40<br />

5 50 ULT50<br />

Specification Chart #3—<br />

Breaker Troughs a<br />

Stack<br />

Positions<br />

Widtha<br />

(Inches)<br />

Catalog<br />

Number<br />

2 20 UBT20<br />

3 30 UBT30<br />

4 40 UBT40<br />

5 50 UBT50<br />

a Use Murray Type MP-T circuit breakers.<br />

Breakers not included.<br />

b Height is 16”.<br />

Specification Chart #4—Phase Blocks<br />

240V AC max. 1 Phase or 3 Phase<br />

Number of<br />

Take-off Lugs Catalog Number<br />

Wire Range<br />

Linea<br />

Load<br />

3 UPB3 3/8 x 16 Stud #6 - #4/0<br />

6 UPB6 3/8 x 16 Stud #6 - #4/0<br />

12 UPB12 3/8 x 16 Stud #6 - #4/0<br />

a Requires separate line lug kit.<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-81


Group Metering: NYC Gangable Metering<br />

Terminals & Accessories<br />

2<br />

METER<br />

CENTERS<br />

Line Terminals<br />

(Use Specification Chart #5)<br />

Knowing the size and quantity per<br />

phase of the line conductors, select and<br />

spec these from Specification Chart #5.<br />

Line terminals come in kits of four terminal<br />

each. One kit will supply line terminals<br />

for three phase legs and neutral.<br />

End Walls<br />

(Use Specification Chart #6)<br />

NOTE: Each installation MUST have<br />

an end wall kit! The kit provides end<br />

walls for each end of the line and<br />

breaker troughs. (Four end walls). Use<br />

Specification Chart #6.<br />

Coupling Kits<br />

(Use Selection Chart #2 and<br />

Specification Chart #6)<br />

When more than one line trough is<br />

needed to support the number of<br />

meter stacks on a job, or when a line<br />

trough spacer is required, coupling<br />

straps are required to connect the<br />

troughs. Use Selection Chart #2 footnotes<br />

3 and 4 to determine quantity<br />

of coupling kits required. Each kit provides<br />

one strap for line trough and one<br />

strap for breaker trough. Spec from<br />

Specification Chart #6.<br />

Line Trough Spacer Kits<br />

(Use Selection Chart #2 and<br />

Specification Chart #6)<br />

In some applications, the first phase<br />

block may be too close to the end wall<br />

of the line trough to provide proper wire<br />

bend space for the line conductors being<br />

used. Selection Chart #2 footnotes 1<br />

and 2 will show when spacer kits are<br />

required.<br />

Tenant Circuit Breakers<br />

Each meter position in use requires a<br />

tenant circuit breaker. Use standard<br />

Murray Type MP-T circuit breakers from<br />

the Murray Catalog.<br />

Specification Chart #5—Line Terminals<br />

Wire Range<br />

Catalog Number<br />

(1) #6-350 kcmil ULK1350<br />

(1) #4-500 kcmil or<br />

ULK1500<br />

(2) #1/0-250 kcmil<br />

(2) #2-600 kcmil ULK2500<br />

Specification Chart #6—End Wall and Coupling Kits<br />

Item<br />

End Wall Kit<br />

Contains 4 end walls; 2 for line<br />

trough and 2 for breaker trough.<br />

Coupling Kit<br />

Contains 2 coupling straps; 1 for line<br />

trough and 1 for breaker trough.<br />

Catalog Number<br />

UEW1216<br />

UCP1216<br />

Specification Chart #7—Accessories<br />

Item<br />

Spacer<br />

10” spacer for use with line trough to<br />

provide wire bend space where required<br />

Meter Cover<br />

Blank Position Cover<br />

Plastic Meter Cover (Ring Type)<br />

Breaker Filler Plate<br />

Catalog Number<br />

ULT10SP<br />

UMCVR<br />

UMBCVR<br />

SX087M<br />

LX100FP<br />

2-82<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Power Mod and Uni-PAK<br />

SPEEDFAX TM<br />

Section<br />

Power Mod<br />

Meter Stack<br />

Uni-PAK Meter Center<br />

Power Mod is built upon service, quality, and flexibility<br />

Siemens Power Mod is a robust, flexible, and feature-rich line of modular metering<br />

designed to exceed today’s market demands. Power Mod’s exclusive QuickSystem<br />

has been proven to reduce labor by as much as 43% over comparable solutions<br />

while exclusive products such as the BFT Main Feed Thru family of mains, allow for<br />

lower material cost and incredible flexibility.<br />

Uni-PAK Metering offers maximum flexibility and ease of installation<br />

Siemens Uni-PAK Metering offers maximum flexibility and ease of installation to meet<br />

the service requirements of multiple position metering projects. The outdoor/indoor<br />

devices are available in two through six gang set-ups which consist of a pull section<br />

with main lugs or stud terminations, and 4/5 jaw meter sockets with tenant circuit<br />

breaker provisions.<br />

c o n t e n t s<br />

Power Mod Modular Metering 3-2 – 3-104<br />

Overview of Power Mod Families 3-2 – 3-10<br />

Configuration Tips and Applications 3-11 – 3-13<br />

WB — Standard and Skinny Circuit Breaker Mains 3-14 – 3-19<br />

WEB — Circuit Breaker Pullbox Combinations 3-20 – 3-23<br />

WXB — Cross Bus Mains 3-24 – 3-26<br />

WBT — Feed Thru Tap Box with Breaker 3-27 – 3-29<br />

BFT — Main Feed Thru 3-30 – 3-32<br />

WS — Standard Switch Mains 3-33 – 3-35<br />

WES — Switch Pullbox Combinations 3-36 – 3-38<br />

WXS — Cross Bus Switch Mains 3-39 – 3-41<br />

WTB — Standard Tap boxes 3-42 – 3-45<br />

WET — Tap box Pullbox Combinations 3-46 – 3-48<br />

WT — Feed-Thru Tap boxes 3-49 – 3-51<br />

WMM — Residential Meter Stacks 3-52 – 3-57<br />

WML — Lever Bypass Meter Stacks 3-58 – 3-67<br />

WMLZ — Fusible Residential Lever Bypass Meter Stacks 3-68 – 3-72<br />

WMT — Test Block Bypass Meter Stacks 3-73 – 3-75<br />

WMK — K-Base Meter Stacks 3-76 – 3-78<br />

WC, WCL, WCT — House Power Modules 3-79 – 3-88<br />

WSPD — Surge Protection Units 3-89 – 3-93<br />

WMN — ConEd Residential Meter Stacks 3-94 – 3-96<br />

WTBN — ConEd Tap boxes 3-98 – 3-100<br />

WMMB — Aux Pull Box 3-101 – 3-102<br />

Elbows and Spacers 3-103 – 3-104<br />

3 METER<br />

CENTERS<br />

Scan to connect<br />

online to the<br />

most up-todate<br />

version of<br />

this Section of<br />

SPEEDFAX.<br />

Uni-PAK Meter Centers 3-105 – 3-127<br />

Introduction 3-105 – 3-107<br />

WP Ring Style Meter Centers 3-108<br />

WP Ringless Style Meter Centers — No Bypass 3-109<br />

WP Ringless Style Meter Centers — Horn Bypass 3-110<br />

WEP EUSERC Ringstyle 3-111<br />

WPL Ringless, Lever Bypass 3-112<br />

Knockout Diagrams 3-113 – 3-127<br />

Accessories and Replacement Parts 3-128 – 3-140<br />

(Section was last modified on 11/20/20)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-1


Power Mod<br />

Revised on 12/13/17<br />

Introduction to QuickSystem Features<br />

Contractor-focused features, robust quality, dependable service, and exclusive products define Siemens Power Mod. The new<br />

standard in multi family metering. QuickSystem showcases the key strengths of Power Mod through five labor saving features:<br />

QuickConnect<br />

A Siemens exclusive feature, QuickConnect reduces<br />

bussing connections from many to one – ensuring<br />

a single reliable connection instead of multiple<br />

connections.<br />

Siemens<br />

exclusive<br />

feature<br />

3<br />

METER<br />

CENTERS<br />

QuickTorque<br />

QuickTorque eliminates the need for time consuming<br />

torque readings. This breakaway nut provides a<br />

visual indicator of torque for the QuickConnect.<br />

When tightened, the outer head twists off at the proper<br />

torque for connection, leaving a single nut for future<br />

maintenance.<br />

QuickBolt<br />

A Siemens exclusive feature, QuickBolt eliminates the<br />

requirement to line up mechanical connections – instead<br />

bolts remain retracted until the openings line up – allowing<br />

the bolts to protrude through automatically. Springs push<br />

the bolts through and provide positive pressure to keep<br />

bolts in place while wingnuts are attached and tightened.<br />

Siemens<br />

exclusive<br />

feature<br />

QuickRoll<br />

A Siemens exclusive feature, QuickRoll eliminates<br />

typical metal brackets for mounting modules on<br />

the wall. Instead of metal scraping metal, QuickRoll<br />

allows the module to glide down the mounting rail<br />

via a durable nylon wheel inside a mounting bracket.<br />

Siemens<br />

exclusive<br />

feature<br />

QuickPhase<br />

Each individual meter position can be phased<br />

independently according to the users needs.<br />

QuickPhase allows the user the ultimate flexibility<br />

to adjust to each individual application. Some<br />

exclusions apply.<br />

3-2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 12/13/17<br />

Introduction to Basic Features<br />

Siemens Modular Metering includes an assortment of module<br />

types that can be configured to meet a wide range of residential<br />

and commercial group metering applications.<br />

Siemens modular metering provides for single phase, three<br />

wire, 120/240V AC; three phase, four wire 120/208Y<br />

applications, and three phase in/out, 240 Volt max delta systems.<br />

The cross bus that connects devices is aluminum and<br />

has a 1200 Amp continuous current rating.<br />

A typical application requires a main device module and one<br />

or more residential or commercial meter stacks. Depending<br />

on the application additional modules such as a pullbox, tap<br />

box, or a spacer may be required.<br />

All of the enclosures are made with G90 galvanized steel and<br />

painted with ANSI 61 paint. All swing latches and rivets are<br />

made with stainless steel.<br />

QuickConnect<br />

The time-saving QuickConnect (QC) provides a single connection for phase,<br />

neutral, and ground – all tightened by a single torque-indicating nut. Factory installed<br />

QuickBolt spring loaded bolts are located just above and below the QC opening<br />

to compress the surrounding gaskets together to form a water-tight seal. For extra<br />

stability additional nuts and bolts above and below QuickBolts are included as a<br />

means of physically joining the meter stacks together both above and below the QC<br />

opening.<br />

3 METER<br />

CENTERS<br />

Siemens<br />

exclusive<br />

feature<br />

Neutral and Ground Provisions<br />

All grounds and neutrals may be relocated toward the top or bottom of the<br />

enclosure depending on where the cables exit.<br />

Tenant Breaker Provisions<br />

Each 225 Amp meter socket has a provision for a 2-pole 225A max plug-in type<br />

QS circuit breaker. The compact QS breaker fits in two inches and reduces<br />

enclosure size limited total mounting space required. Single right hand bend wiring<br />

saves time and wire. Insert a 125A QP into a 225 Amp QS slot without conversion<br />

kits or filler plates. Generous gutter space allows for wires to exit the top, bottom,<br />

or back of the meter module.<br />

WMM Module factory phasing is as follows:<br />

2 Gang: AB, BC<br />

3 Gang: AB, BC, AC<br />

4 Gang: AB, BC, AC, AB<br />

5 Gang: AB, BC, AC, AB, BC<br />

6 Gang: AB, BC, AC, AB, BC, AC<br />

Any position can be adjusted to any phase in the field.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-3


Power Mod<br />

Revised on 06/30/19<br />

Overview of Families<br />

3<br />

METER<br />

CENTERS<br />

WB – Standard Circuit Breaker Mains<br />

Standard breaker modules (type WB) offer a balance<br />

between functionality, feature, and size constraints.<br />

Features include:<br />

n Compression lug landing pads (field install up to<br />

1200 Amps, standard feature up to 2000 Amps)<br />

n Combination overhead and underground feed up<br />

to1200 Amps, dedicated overhead or under ground<br />

feed up to 2000 Amps<br />

n 750kcmil AL wire options<br />

n 65K AIC standard, 100K AIC available for all models<br />

n Removable blank bottom endwall<br />

n Externally accessible breaker handle with<br />

padlock capability<br />

n Broad ampacity ratings up to 2000 Amps with nonstandard<br />

amperages available (such as 700, 900, etc.)<br />

n Field installable shunt trips<br />

n DAS blue light models available in amperages of<br />

1200-1600A<br />

Standard Circuit Breaker<br />

Mains quick reference<br />

n 200-2000A module rating<br />

n 1200A horizontal bus rating<br />

n UL Standard # 67<br />

n UL file # E27100<br />

n AIC rating (65k and 100k)<br />

n Voltage:<br />

– Single phase 120/240V AC max<br />

– Three phase 240V AC max<br />

n NEMA 3R rated<br />

WEB – Circuit Breaker-Pullbox Combinations<br />

EUSERC - compliant breaker - pullbox combination<br />

modules (type WEB) offer EUSERC compatibility,<br />

a wider range of lug options, and extra space for<br />

pulling in conductors.<br />

Features include:<br />

J NEMA 2-stud lug mounting pattern<br />

J 750 kcmil AL wire options<br />

J 65K AIC standard, 100K AIC available for all models<br />

J Removable blank bottom endwall<br />

J Externally accessible breaker handle with<br />

padlock capability<br />

J Field installable shunt trips<br />

J Large removable ground wire trough with<br />

generous space for grounding conductors<br />

J DAS blue light models available in 1200A<br />

Circuit Breaker-Pullbox<br />

Combo quick reference<br />

n 200-1200A module rating<br />

n 1200A horizontal bus rating<br />

n UL standard # 67<br />

n UL file # E27100<br />

n AIC rating (65k and 100k)<br />

n Voltage<br />

– Single phase 120/240V AC Max<br />

– Three phase 240V AC Max<br />

n NEMA 3R rated<br />

n EUSERC drawing number 347<br />

WXB – Cross Bus Main<br />

The WXB family of main breaker devices features incoming<br />

and out-going horizontal bus connections (no incoming<br />

lugs). This patented design allows the user to utilize<br />

the WXB family to connect to Siemens Sentron Busway<br />

or connect to a tap box (or other main) to lower the overall<br />

ampacity of the service disconnect. In addition users<br />

can now utilize incoming tap boxes to split the service<br />

between multiple mains. This can save the end-user<br />

on the material cost of the meter bank. Please see the<br />

applications pages for more information.<br />

Features include:<br />

J Incoming and Outgoing Power Mod horizontal bus<br />

J 65K AIC standard, 100K AIC available for all models<br />

J Broad ampacity ratings up to 1200 amps with nonstandard<br />

amperages available (such as 700, 900, etc…)<br />

J Field installable shunt trip<br />

J DAS blue light models available in 1200A<br />

Cross Bus Mains<br />

quick reference<br />

J 400-1200A module rating<br />

J 1200A horizontal bus rating<br />

J UL Standard #67<br />

J UL file # E27100<br />

J AIC rating (65k and 100k)<br />

J Voltage:<br />

– Single phase<br />

120/240V AC max<br />

– Three Phase<br />

240V AC max<br />

J NEMA 3R (outdoor)<br />

3-4<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 06/30/19<br />

Overview of Families<br />

WBT - Feed Thru Tap Box with Horizontal Bus Breaker<br />

Feed thru tap box and breaker module (type WBT) offers<br />

the ability to pull conductors in and out of the enclosure for<br />

rise cable or loop feed applications as well as a main breaker<br />

device utilizing an incoming and out-going thru bus connections<br />

(including incoming lugs). This patented design allows the user to<br />

utilize the WBT family to connect to Siemens Sentron Busway.<br />

Features include:<br />

n Incoming and Outgoing Power Mod thru bus<br />

n Standard compression lug capability<br />

n 65K AIC standard, 100K AIC available for all models<br />

n Broad ampacity ratings up to 1200 Amps<br />

n DAS blue light models available in 1200A<br />

Feed Thru Tap Box with<br />

Breaker quick reference<br />

n 200-1200A breaker rating<br />

n 1200-2400A feed-thru rating<br />

n 1200A horizontal bus rating<br />

n UL Standard #67<br />

n UL file #E27100<br />

n AIC rating (65K and 100K)<br />

n Voltage:<br />

– Three Phase 240V AC max<br />

n NEMA 3R rated<br />

Restrictions for WBT Feed Thru breaker tapbox units:<br />

Type WBT feed thru breaker tap boxes cannot be used as service equipment. The feed thru conductors must<br />

have upstream circuit protection. For feed thru conductor ratings up to 2,000 amps, Siemens Sentron or VL circuit<br />

breakers can be used. For feed thru conductor ratings over 2,000 amps but up to 2,400 amps, use Class L fuses.<br />

Please note that Siemens type WL circuit breakers CANNOT be used as the direct upstream main for these WBT<br />

feed thru breaker tap boxes.<br />

BFT - Main Feed Thru<br />

Main feed thru (type BFT) breaker modules has the ability to<br />

isolate power to side-mounted modules just like any other<br />

Power Mod main breaker module, but also contains feed-through<br />

lugs that can be used to supply and isolate power vertically to<br />

downstream group metering line ups.<br />

Features include:<br />

n Incoming and Outgoing Power Mod thru bus<br />

n Standard compression lug capability<br />

n 65K AIC standard, 100K AIC available for all models<br />

n Main breaker with broad ampacity ratings from<br />

1200A to 2000A<br />

n DAS blue light models available in amperages of 1400-1600A<br />

n For 1200A DAS you must use a 1400A DAS module and have<br />

the trip setting dialed down to 1200A in the field.<br />

WS – Standard Switch Mains<br />

Standard switch modules (type WS) are designed for flexibility,<br />

space savings, and durability.<br />

Features include:<br />

n Standard compression lug capability<br />

n Invertibility: 400-800 Amp devices can be rotated to accommodate<br />

the desired incoming feed direction<br />

n 750 kcmil AL wire options for most models<br />

n 100K AIC standard for all models<br />

n Class T fuse provisions<br />

n Broad ampacity ratings up to 1200 Amps<br />

Main Feed Thru<br />

quick reference<br />

n 1200-2000A module<br />

rating (breaker)<br />

n 1200-2000A feed-thru rating<br />

n 1200A horizontal bus rating<br />

n UL Standard #67, file #E27100<br />

n AIC rating (65K & 100K)<br />

n Voltage: 240V AC max<br />

n Available in single and three phase<br />

n NEMA 1 (Indoor)<br />

n Bottom feed only<br />

n All units come with no hubs<br />

n EUSERC drawing number 347<br />

(EUSERC applies to 1200A unit only)<br />

Standard Switch Mains<br />

quick reference<br />

n 200-1200A module rating<br />

n 1200A horizontal bus rating<br />

n 1200A thru-bus rating<br />

n UL Standard # 98<br />

n<br />

UL file #E25506<br />

n AIC rating (100k AIC)<br />

n Voltage:<br />

– Single phase 120/240V AC max<br />

– Three phase 240V AC max<br />

n NEMA 3R rated<br />

3 METER<br />

CENTERS<br />

WES – Switch-Pullbox Combinations<br />

EUSERC - compliant switch-pullbox combination modules (type<br />

WES) offer EUSERC compatibility, a wider range of lug options,<br />

and extra space for pulling in conductors.<br />

Features include:<br />

n NEMA 2-stud lug mounting pattern<br />

n Broad ampacity ratings up to 1200 Amps<br />

n 750kcmil AL wire options<br />

n 100K AIC standard for all models<br />

n Removable blank bottom endwall<br />

n Class T fuse provisions<br />

n Extra ground lugs in each device<br />

Switch-Pullbox<br />

Combo quick reference<br />

n 400-1200A module rating<br />

n 1200A horizontal bus rating<br />

n UL standard # 98<br />

n UL file # E25506<br />

n AIC Rating (100k AIC)<br />

n Voltage:<br />

– Single phase 120/240V AC max<br />

– Three phase 240V AC max<br />

n NEMA 3R rated<br />

n EUSERC drawing numbers 315, 343,<br />

and 347<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-5


Power Mod<br />

Revised on 10/31/19<br />

Overview of Families<br />

3<br />

METER<br />

CENTERS<br />

WXS – Cross Bus Switch<br />

The WXS family of switches offers a<br />

standardized means of connecting Siemens<br />

Sentron busway to Power Mod for mid and<br />

high-rise applications. The Sentron Busway is<br />

connected via the TapStack which converts<br />

Sentron busway connections over to Power<br />

Mod horizontal bus connections. This enables<br />

the user to connect to Power Mod in as little as<br />

9” of wall space.<br />

Features include:<br />

n Fast connection of end-feed busway<br />

to Power Mod meter banks<br />

n Class T fuse provisions<br />

n 100K AIC standard for all models<br />

Pull Box quick reference<br />

n 400-800A module rating<br />

n 1200A horizontal bus rating<br />

n UL Standard #98<br />

n UL file # E25506<br />

n AIC rating: 100K<br />

n Voltage<br />

– Single phase 120/240V AC max<br />

– Three Phase 240V AC max<br />

n NEMA 3R rated<br />

WTB – Standard Tap boxes<br />

Standard tap box modules (type WTB) are designed<br />

for versatility, space savings, and flexibility.<br />

Features include:<br />

J Standard compression lug capability<br />

J Invertibility: devices can be rotated to<br />

accommodate<br />

the desired incoming feed direction<br />

J 750 kcmil AL wire options for most models<br />

J 100K AIC standard for all models<br />

J Broad ampacity ratings from 400 to 2400 Amps<br />

J Line and load capability- service entrance and<br />

sub-feed rated<br />

Standard Tap box quick reference<br />

J 400-2400A module rating<br />

J 1200A horizontal bus rating<br />

J UL Standard # 67<br />

J UL file # E27100<br />

J AIC rating (100K AIC)<br />

J Voltage<br />

- Single phase 120/240V AC max<br />

- Three phase 240V AC max<br />

J All swing latches and rivets are stainless steel.<br />

J NEMA 3R rated<br />

Restrictions for 1600-2400amp type WTB Power Mod Tap Boxes:<br />

When the 1600, 2000, or 2400amp tap boxes are used as service entrance equipment (fed directly from utility<br />

transformer) or when the supply originates from a Class L fuse or Siemens WL circuit breaker there are<br />

restrictions on the use of an additional down-stream horizontal cross-bus connected WTBN, WTB, WET, or WT<br />

type Power Mod tap boxes. When another tap box is connected to the same meter-bank, a type “WXB” module<br />

must be used as protection for the down- stream tap box (placed between the incoming WTB tap box and the<br />

downstream outgoing tap box). This restriction does NOT apply if the tap box is fed from a Siemens Sentron or<br />

VL series molded case circuit breaker. Note that the maximum amperage for a Siemens Sentron circuit breaker<br />

is 2,000amps.<br />

WET – Tap box - Pullbox Combinations<br />

EUSERC - compliant Tap box-Pullbox Combination<br />

modules (type WET) offer EUSERC compatibility,<br />

a wider range of lug options, and extra space for<br />

pulling in conductors.<br />

Features include:<br />

J Standard compression lug capability<br />

J 750 kcmil AL wire options for most models<br />

J 100K AIC standard for all models<br />

J Broad ampacity ratings from 400 to 1200 Amps<br />

J Removable bottom endwall<br />

Tap box – Pullbox Combination<br />

quick reference<br />

J 400-1200A module rating<br />

J 1200A horizontal bus rating<br />

J UL Standard #’s 67<br />

J UL file # E27100<br />

J AIC Rating (100k)<br />

J Voltage<br />

- Single phase 120/240V AC max<br />

- Three phase 240V AC max<br />

J All swing latches and rivets are stainless steel.<br />

J NEMA 3R rated<br />

J EUSERC drawing numbers 343, 343A, 347 (Pullbox)<br />

3-6<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 10/31/19<br />

Overview of Families<br />

WT – Feed Thru Tap box<br />

Feed-thru tap boxes (type WT) offer the ability to pull<br />

conductors in and out of the enclosure for riser cable or<br />

loop feed applications.<br />

Features include:<br />

J Standard compression lug capability<br />

J 750kcmil AI wire options<br />

J 100k AIC standard<br />

J Removable bottom endwall<br />

J Broad ampacity ratings from 400 to 2400 Amps<br />

Feed Thru Tap box<br />

quick reference<br />

J 400-2400A module rating<br />

J 400-2400A feed-thru rating<br />

J 1200A horizontal bus rating<br />

J UL Standard #67<br />

J UL file no. E27100<br />

J AIC rating (100k AIC)<br />

J Voltage<br />

- Single phase 120/240V AC max<br />

- Three phase 240V AC max<br />

J NEMA 3R rated<br />

Restrictions for 1600-2400amp type WT Power Mod Pull-Thru Tap Boxes:<br />

Type WT feed thru tap boxes cannot be used as service equipment. The feed thru conductors must have<br />

upstream circuit protection. When fed by a Class L fuse, there are restrictions on the use of additional downstream<br />

horizontal cross-bus connected WTBN, WET, or WT type Power Mod tap boxes. When another tap box<br />

is connected to the same meter-bank, a type WXB module must be used as protection for the downstream tap<br />

box (placed between the incoming WT tap box and the downstream outgoing tap box). This restriction does<br />

NOT apply if the tap box is fed from a Siemens Sentron or VL series molded case circuit breaker. Note that the<br />

maximum amperage for a Siemens Sentron circuit breaker is 2,000A. Please note that Siemens type WL circuit<br />

breakers CANNOT be used to feed WT Power Mod tap boxes.<br />

3 METER<br />

CENTERS<br />

WMM – Residential Meter Stacks<br />

The residential meter stacks (type WMM) are designed<br />

for residential applications. This core product offers many<br />

variations to meet the customers' requirements.<br />

Features include:<br />

J Movable neutrals and grounds.<br />

J Pivoting rain gutter.<br />

J Removable back plate.<br />

J Center punch dimples (outdoor).<br />

J QP breakers used in 125A.<br />

J 225A versions can use QS or QP breakers.<br />

Residential Meter Stacks<br />

quick reference<br />

J 2-6 gang<br />

J 125/225 Amp per position<br />

J 1200 Amp horizontal-bus rating<br />

J UL Standard #67 and #414<br />

J UL file no. E27100<br />

J AIC rating (100k)<br />

J Voltage:<br />

– Single phase 120/240V AC max.<br />

– Three phase in single phase out<br />

• 120/208V AC max.<br />

• 240/120V AC max.<br />

J Outdoor= NEMA 3R rated<br />

J Indoor= NEMA 1 rated<br />

J Ring type units comply with EUSERC<br />

drawing number 353<br />

WML – Lever Bypass Meter Stacks<br />

Commercial Lever Bypass meter stacks (type WML)<br />

are designed to meet the requirements of those utilities<br />

specifying lever bypass meter sockets for residential and<br />

commercial applications.<br />

Features include:<br />

J High-quality, time-proven Talon HQ sockets<br />

J A line of 3-phase 100 Amp meter stacks to<br />

minimize tenant main cost<br />

J Removable back knockout plate to facilitate wiring<br />

J 225 Amp capability in single and three phase designs<br />

J Up to 4 positions with 225 Amp tenant mains,<br />

up to 2 positions with 400 Amp tenant mains<br />

J Ease of wiring – tenant mains require only a<br />

single bend<br />

Lever Bypass quick reference<br />

J 100A/225A 1-4 position<br />

J 400A 1-2 position<br />

J 1200A horizontal-bus rating<br />

J UL Standard # UL67<br />

J UL file # E27100<br />

J AIC rating (25K, 65K and 100K)<br />

J Voltage<br />

– Single phase 120/240V AC max<br />

– Three in single phase out 208Y/120V AC<br />

– Three Phase 240V AC max<br />

J All swing latches and rivets are<br />

stainless steel.<br />

J Outdoor = NEMA 3R rated<br />

J Indoor = NEMA 1 rated<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-7


Power Mod<br />

Revised on 06/30/19<br />

Overview of Families<br />

3<br />

WML - Fusible Switch Lever Bypass Meter stacks<br />

This Commercial Lever Bypass meter stacks (type WML)<br />

feature a 400 Amp - class T - fusible pull out assembly.<br />

Features include:<br />

J High-quality, time proven Talon HQ sockets<br />

J Removable back knockout plate to facilitate wiring<br />

J Available in single and three phases designs<br />

J Single position with 400 Amp tenant main<br />

J Ease of wiring<br />

Lever Bypass With Fusible<br />

Switch Quick Reference:<br />

J 400A 1 position<br />

J 1200A horizontal bus rating<br />

J UL Standard #UL67<br />

J UL file #E27100<br />

J AIC rating 65KAIC<br />

J Voltage:<br />

– Single phase 120/240V AC max<br />

– Three phase in, single phase out<br />

208Y/120V AC<br />

– Three Phase 240V AC max<br />

J Outdoor= NEMA 3R rated<br />

J Indoor= NEMA 1 rated<br />

METER<br />

CENTERS<br />

WMLZ/ WMLZF – Fusible Residential Lever<br />

Bypass Meter Stacks<br />

The WMLZ and WMLZF lever bypass meter stacks are<br />

designed to allow the use of class T (400 Amp max)<br />

fuses ahead of all meter positions where the local serving<br />

utility may require it. WMLZF stacks feature a 400 Amp<br />

fusible pull out assembly which connects to a secondary<br />

400 Amp horizontal bus that can feed downstream<br />

meter stacks. The WMLZ stacks include the secondary<br />

horizontal bus that can connect from the WMLZF meter<br />

stacks. The standard Power Mod 1200amp horizontal bus<br />

"passes thru" to feed downstream modules – the meter<br />

sockets in WMLZ and WMLZF do NOT connect directly<br />

to the 1200 Amp horizontal bus – only to the 400 Amp<br />

horizontal bus.<br />

Features include:<br />

J High-quality, time proven Talon HQ sockets<br />

J 125 Amp capability for 3-phase in/ single-phase out<br />

J 3 to 6 positions in botht the fused stack and the<br />

expansion stack<br />

J 400 Amp class T fusible-pullout in WMLZF stacks<br />

J Secondary 400 Amp thru bus to supply power to down<br />

stream sockets<br />

J Ease of wiring – tenant mains require only a single<br />

bend<br />

J Preconfigures and wired.<br />

WMT – Test Block Bypass Meter Stacks<br />

Commercial Test Block Bypass Meter Stacks (type<br />

WMT) are designed to meet the requirements of those<br />

utilities specifying test block bypass meter sockets for<br />

commercial applications in areas subscribing to the<br />

EUSERC standards.<br />

Features include:<br />

J High-quality, time-proven Siemens SMM<br />

switchboard meter socket<br />

J Removable back knockout plate to facilitate wiring<br />

J 225 Amp capability in single and three phase designs<br />

J Up to 3 positions with 225 Amp tenant mains<br />

J Wiring flexibility - tenant mains require only a<br />

single bend<br />

J Three phase input, single phase output modules<br />

J In line wiring: side knockouts allow wiring for<br />

adjacent units to pass through<br />

Xcel Residential Lever<br />

Bypass Quick Reference:<br />

J 125A 3-6 position<br />

J 1200A horizontal bus rating<br />

J 400A secondary horizontalbus<br />

rating and vertical<br />

bus rating<br />

J UL Standard #UL67<br />

J UL file #E27100<br />

J AIC rating (100K)<br />

J Voltage<br />

– Three phase in, single phase out<br />

208Y/120V AC<br />

J Outdoor = NEMA 3R rated<br />

J Indoor = NEMA 1 rated<br />

Test Block Bypass<br />

quick reference<br />

J 225A 1-3 positions<br />

J 1200A horizontal bus rating<br />

J UL Standard #’s 67<br />

J UL file # E27100<br />

J AIC Rating (100k)<br />

J Voltage<br />

– Single phase 120/240V AC max<br />

– 3 phase in single phase out<br />

120Y/208V AC max<br />

– Three phase 240V AC max<br />

J Outdoor= NEMA 3R rated<br />

J Indoor= NEMA 1 rated<br />

J EUSERC drawing numbers 312 and 353<br />

3-8<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 06/30/19<br />

Overview of Families<br />

WSPD – Integral surge protection device for<br />

multi-family applications<br />

Surge protection modules for Power Mod (type WSPD)<br />

are horizontal-bus connected modules that allow the<br />

user to view surge status as well as access the SPD<br />

control panel without breaking the utility seal on the<br />

enclosure. An optional breaker disconnect is available to<br />

enable the end user to replace the SPD (surge protection<br />

device) without having to disconnect utility power to<br />

the Power Mod installation.<br />

Features include:<br />

J 100,200,300,400,500kA ratings available<br />

J External, vandal resistant and lockable clear cover<br />

over SPD control panel<br />

J Single phase horizontal bus and three phase<br />

horizontal bus<br />

J Optional breaker disconnect that opens phase and<br />

neutral to make SPD replacement quick and easy<br />

Surge Module<br />

quick reference<br />

J 100-500kA ratings<br />

available<br />

J 1200A horizontal<br />

bus rating<br />

J UL Standard #67<br />

J UL file # E27100<br />

J AIC rating: 100K<br />

J Voltage<br />

– Single phase 120/240V AC max<br />

– Three Phase 240V AC max<br />

J NEMA 3R rated<br />

3 METER<br />

CENTERS<br />

WMK – K-Base Meter Stacks<br />

Commercial K-Base Meter Stacks (type WMK) are<br />

designed to meet the requirements of those utilities<br />

specifying bolt-in meter sockets for 400 and 600 Amp<br />

residential and commercial applications.<br />

Features include:<br />

J Exclusive Talon K4, K5, and K7 meter sockets<br />

J 1 position K4, K5, K7 modules with 400 and 600<br />

Amp tenant mains<br />

J 2 position K7 module with 400 Amp<br />

tenant main<br />

J Space saving design<br />

K-Base<br />

quick reference<br />

J 400A and 600A<br />

1-2 positions<br />

J 1200A horizontal<br />

bus rating<br />

J UL Standard # 67<br />

J UL file # E27100<br />

J AIC Rating (25k)<br />

J Voltage<br />

– Single Phase 120/240V AC Max<br />

– Three In Single Phase Out<br />

208Y/120V AC<br />

– Three Phase 240V AC Max<br />

J NEMA 3R rated<br />

WMMB – auxillary pull boxes for use with WB, WTB,<br />

and WS Power Mod modules<br />

Auxillary pull boxes are used in cases where WEB, WES,<br />

or WET modules were not or cannot be used, but the<br />

user still needs to comply with the EUSERC standard.<br />

These modules feature incoming NEMA 2-stud lug<br />

mounting pattern lugs for underground feed and allow<br />

the user to pull wire from the lug landing in the pull box<br />

thru a 6” knockout and into: 400-1200amp WB, WTB<br />

and 400-800amp WS modules. Note this family does<br />

NOT have horizontal bus, it's intended only for lug in/lug<br />

out applications.<br />

Features include:<br />

J 6” side opening (right or left) with available<br />

gasket to help mitigate wire insulation damage<br />

J EUSERC compliant incoming pull section<br />

Pull Box<br />

quick reference<br />

J 400, 800,1200 Amp<br />

J UL Standard #67<br />

J UL file # E27100<br />

J AIC rating: 100K<br />

J Voltage<br />

– Single phse 120/240V AC max<br />

– Three Phase 240V AC max<br />

J NEMA 3R rated<br />

J No horizontal bus<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-9


Power Mod<br />

Revised on 06/30/19<br />

Overview of Families<br />

3<br />

METER<br />

CENTERS<br />

WC – Residential meter socket with load center<br />

distribution panel<br />

The meter-load center combination offered by the WC<br />

series is unique and exclusive to the Siemens Power<br />

Mod family. This product offers the ability to combine<br />

house power applications with a meter socket thereby<br />

reducing material (pipe and wire) and installation time<br />

(separate load center or panel board).<br />

Features include:<br />

J Single phase horizontal bus and three phase<br />

horizontal bus<br />

J 20 space - 40 circuit interior for single phase out<br />

put devices<br />

J 24 space - 42 circuit interior for three phase out<br />

put devices<br />

J Copper bus PL Series Siemens load center interior<br />

J Dual neutral and ground provisions with Siemens<br />

patented Instawire technology<br />

J Optional subfeed breaker for elevator applications<br />

J 250 Amp overall device rating<br />

WC House Power Panel<br />

quick reference:<br />

J 250 Amp, 1 position<br />

J 1200 Amp horizontal<br />

bus rating<br />

J UL Standard #67<br />

J UL Standard #414<br />

J UL file # E27100<br />

J AIC rating: 100K<br />

J Voltage<br />

– Single phase 120/240V AC max<br />

– Three in single phase out 208Y120V AC<br />

– Three Phase 240V AC max<br />

J NEMA 3R rated<br />

J Copper load center bus bars<br />

J 125Amp MAX subfeed breaker- factory<br />

installed (type HED4)<br />

J 225Amp MAX main breaker- factory<br />

installed (type HFD6)<br />

WCL – Commercial Lever Bypass meter socket with<br />

load center distribution panel<br />

The meter-load center combination offered by the WCL<br />

series is unique and exclusive to the Siemens Power Mod<br />

family. This product offers the ability to combine house<br />

power applications with a meter socket thereby reducing<br />

material (pipe and wire) and installation time (separate load<br />

center or panel board). WCL modules feature the Talon<br />

HQ lever bypass for those utilities that specify lever bypass<br />

for residential and commercial applications.<br />

Features include:<br />

J Single phase horizontal bus and three phase<br />

horizontal bus<br />

J 20 space - 40 circuit interior for single phase out<br />

put devices<br />

J 24 space - 42 circuit interior for three phase out<br />

put devices<br />

J Copper bus PL Series Siemens load center interior<br />

J Dual neutral and ground provisions with Siemens<br />

patented Instawire technology<br />

J Optional subfeed breaker for elevator applications<br />

J 250 Amp overall device rating<br />

WCL House Power Panel<br />

quick reference:<br />

J 250 Amp, 1 position<br />

J 1200A horizontal bus rating<br />

J UL Standard #67<br />

J UL Standard #414<br />

J UL file # E27100<br />

J AIC rating: 100K<br />

J Voltage<br />

– Single phase 120/240V AC max<br />

– Three in single phase out 208Y120V AC<br />

– Three Phase 240V AC max<br />

J NEMA 3R rated<br />

J Copper load center bus bars<br />

J 125Amp MAX subfeed breaker- factory<br />

installed (type HED4)<br />

J 225Amp MAX main breaker- factory<br />

installed (type HFD6)<br />

WCT – Commercial Test Block Bypass meter socket<br />

with load center distribution panel<br />

The meter-load center combination offered by the WCT<br />

series is unique and exclusive to the Siemens Power<br />

Mod family. This product offers the ability to combine<br />

house power applications with a meter socket thereby<br />

reducing material (pipe and wire) and installation time<br />

(separate load center or panel board). WCT modules feature<br />

a test block bypass socket for utilities subscribing<br />

to the EUSERC standard.<br />

Features include:<br />

J Single phase horizontal bus and three phase<br />

horizontal bus<br />

J 20 space - 40 circuit interior for single phase<br />

out put devices<br />

J 24 space - 42 circuit interior for three phase<br />

out put devices<br />

J Copper bus PL Series Siemens load center interior<br />

J Dual neutral and ground provisions with Siemens<br />

patented Instawire technology<br />

J Optional subfeed breaker for elevator applications<br />

J 250amp overall device rating<br />

WCT House Power Panel<br />

quick reference:<br />

J 250 Amp, 1 position<br />

J 1200 Amp horizontal<br />

bus rating<br />

J UL Standard #67<br />

J UL Standard #414<br />

J UL file # E27100<br />

J AIC rating: 100K<br />

J Voltage<br />

– Single phase 120/240V AC max<br />

– Three in single phase out 208Y120V AC<br />

– Three Phase 240V AC max<br />

J NEMA 3R rated<br />

J Copper load center bus bars<br />

J 125Amp MAX subfeed breaker- factory<br />

installed (type HED4)<br />

J 225Amp MAX main breaker- factory<br />

installed (type HFD6)<br />

3-10<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 06/30/19<br />

Introduction<br />

The breadth of the Power Mod product line is un-matched<br />

in the industry today. The available options result in many<br />

different ways to configure the same project with some<br />

solutions focusing on material cost and other solutions that<br />

create the opportunity for labor savings. The following pages<br />

contain examples and tips for using Power Mod in common<br />

multi-family metering applications including, but not limited<br />

to high rise buildings, mixed use, and garden style apartment<br />

complexes.<br />

The following items are configuration tips and rules to keep in<br />

mind:<br />

Ampacity and Bussing<br />

Configurations are limited by the continuous current ratings<br />

for the main device (service entrance) and the horizontal<br />

bus. The Power Mod horizontal bus is always rated for<br />

1200amps from the factory. Siemens does not offer low<br />

800amp rated horizontal bus. All horizontal bus within the<br />

same meter bank must be single phase or three phase.<br />

Single and three phase horizontal bus cannot be mixed<br />

within the same meter bank.<br />

Connections<br />

A QuickConnect is required for each horizontal bus<br />

connection and is supplied with all WMM, WML, WMT,<br />

WC, WCL, WCT, WSPD, WMK, WXB, WXS, BE, WSP and<br />

WELB modules. The QuickConnect houses all phase, neutral,<br />

ground/bonding connections between Power Mod modules.<br />

Utility Requirements<br />

Utilities have varying requirements for equipment height,<br />

cover types, and bypass types. Therefore, utility acceptance<br />

should be verified prior to installation of any equipment. The<br />

COMPAS configuration tool can be utilized by any authorized<br />

Siemens sales or distributor representative to show critical<br />

dimensions of any installation.<br />

Service Entrance Modules and Requirements<br />

n In group metering applications breaker mains larger than<br />

1200A have been used for years as center fed devices<br />

where the load out of either side is 1200A or lower. This<br />

practice is acceptable because the products are tested as a<br />

complete system in accordance with UL standards. When<br />

installed per these instructions, the panelboard will meet<br />

the UL listing of the product and will be consistent with<br />

proven industry standard practice.<br />

n EUSERC-compliant service entrance modules (families<br />

WEB, WES, WET) are underground feed only and offer<br />

a wider range of lug options due to the larger enclosure<br />

size. These devices are also setup for compression lug<br />

installations from the factory.<br />

n Tap boxes (families WTB, WT, WET) provide a direct<br />

connection to the horizontal bus and do not provide any<br />

overcurrent protection. A tap box can be used with the<br />

WXB and WXS cross bus main families. To provide overcurrent<br />

protection to downstream adjacent modules, WTB<br />

and WET tap box families can be used as a service entrance<br />

point or a load side feed for remote equipment. WT feedthru<br />

tap boxes cannot be used as service entrance devices.<br />

An additional QuickConnect must be ordered separately<br />

when using a tap box on the load side. The WTB family<br />

features invertibility on 400–1600amp models. Each item<br />

from this family includes two sets of QuickBolts. The<br />

eventual left side must be removed prior to installation.<br />

n WB service entrance breaker modules: 200-1200amp<br />

modules are combination feed allowing service entrance<br />

conductors to enter the top or bottom of the enclosure.<br />

1400-1600amp WB modules come in top or bottom feed<br />

(combination feed is not available). 2000amp WB modules<br />

are available in dedicated bottom feed or combination feed<br />

configurations.<br />

n WS service entrance switch modules: 400 to 800amp<br />

modules are invertible for top or bottom feed. Each includes<br />

two sets of QuickBolts. The eventual left side must be<br />

removed prior to installation. 1200amp WS modules are<br />

bottom feed only and utilize a molded case switch (looks<br />

like a breaker) for the switching mechanism.<br />

Spacing Requirements<br />

A spacer is commonly required between a meter stack and<br />

a service entrance module. This is usually due to the need to<br />

have a minimum distance (left or right) from the meter to any<br />

obstruction. TIP: when the service entrance main is on the<br />

LEFT and you need a 125amp tenant main WMM stack use<br />

a 225amp WMM meter stack instead. The extra width of the<br />

225amp stack will provide 10” of clearance from the main<br />

and, since you can use a standard Q2100 or Q2125 in the<br />

stack, the cost increase from 125 to 225amp is still less than<br />

adding a spacer (type WSP). This also saves the installation<br />

labor of the spacer.<br />

Breaker Provisions<br />

A tenant breaker must be ordered separately for each tenant<br />

position or configured as factory installed within the COMPAS<br />

configuration tool. Blank filler plates are not available thus<br />

un-used positions must have a breaker installed or the access<br />

cover must be locked.<br />

Space Savings<br />

Utilize the WC-WCL-WCT families to save space. These<br />

devices allow for consolidating the typical setup of a meter<br />

stack and separate panel into a single device if the application.<br />

This allows for less wall space, increased material savings,<br />

and a lower install cost. Please see the configurations on the<br />

following pages for examples.<br />

Material Savings<br />

Utilize the WXB cross bus mains to lower your overall material<br />

cost. When a large ampacity main is needed (1200amps or<br />

above) utilizing a tap box and a WXB main can lower the<br />

overall cost by eliminating costly large frame breakers from the<br />

installation. As shown in figures 3 and 4 the installation does<br />

require more wall space, but the overall dollars are lower.<br />

3 METER<br />

CENTERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-11


Power Mod<br />

Revised on 06/30/19<br />

Applications: Bus Duct Connections<br />

3<br />

METER<br />

CENTERS<br />

Busway application<br />

Siemens Power Mod offers an efficient and standardized<br />

means of connecting Sentron Busway to Power Mod<br />

utilizing the TapStack module. This module connects to a<br />

joint in the busway and converts the bus structure over to<br />

that of the Power Mod horizontal bus in only nine inches.<br />

TapStacks are configured, priced, built, and shipped<br />

with the Sentron Busway. They require an additional<br />

QuickConnect coupler and are for indoor use on end-feed<br />

applications. TapStacks can connect to any Power Mod<br />

horizontal bus.<br />

Options for the user are:<br />

1. Direct Connection: in this option (below) the connection<br />

is made directly to any meter stack family. This<br />

application is for use when the service disconnect is<br />

located at the beginning of the busway.<br />

2. Connection to a service disconnect: in this option a<br />

connection is made to either a WXB cross bus main<br />

or a WXS switch main. Please note that ANY other<br />

mains (WB, WEB, WS, WES) cannot act as a service<br />

disconnect for downstream meter stacks. The WB,<br />

WEB, WS, WES mains CAN be used as tenant mains<br />

on the load-side of a service disconnect for use in<br />

feeding large remote loads such as a CT cabinet. WXB<br />

mains are available up to 1200amps and WXS mains are<br />

available up to 800amps. Both families have 100K AIC<br />

options for all models.<br />

3. Connection to a load-side main: In applications where<br />

branch circuit monitoring is used in lieu of Power Mod a<br />

tap stack plus Power Mod main (WB, WS) can be used<br />

where the installer cables out of the main over to a<br />

distribution panel (Siemens P3, P4, and P5 panel types).<br />

This essentially replaces a bus plug function.<br />

For Center feed bus duct application please contact your<br />

Siemens representative.<br />

Critical and recommended dimensions for<br />

Sentron Busway to Power Mod connections<br />

Tap Stack Module<br />

Warning<br />

Do not connect the Power Mod NEMA 1 corner<br />

units (BE) directly to busway; always use a WELB in<br />

its place or use another module as an intermediary<br />

between the two.<br />

3-12<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 03/31/19<br />

Applications: Bus Duct Solutions<br />

Figure 11<br />

Figure 12<br />

Riser Busway<br />

Example of WXB or WXS cross bus mains protecting stacks being fed by busway<br />

3 METER<br />

CENTERS<br />

Figure 13<br />

Figure 14<br />

Riser Busway<br />

Example of stacks fed by busway tapstack<br />

with an upstream main<br />

Example of stacks being fed by a meter center<br />

cubicle built inline with busway<br />

Figure 15<br />

Riser Busway<br />

Please Note:<br />

n There typically will be an offset off of the<br />

wall coming off of busway<br />

n Strut or artificial walls can be used to mount<br />

power mod when fed by busway<br />

n When fed by a cubicle tapstacks are<br />

not necessary<br />

n Tapstacks are busway products and must be<br />

used when connecting Power Mod products<br />

to busway when a cubicle is not used<br />

n Tapstacks and cubicles transpose busway<br />

phasing to match power mod phasing<br />

A WB main can be used to back-feed<br />

panel board off of busway<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-13


Power Mod<br />

Revised on 06/30/19<br />

Type WB Standard and Skinny Circuit Breaker Mains<br />

Standard and Skinny Circuit<br />

Breaker Mains<br />

Standard breaker modules (type WB) offer a balance<br />

between functionality, feature, and size constraints.<br />

3<br />

METER<br />

CENTERS<br />

Features include:<br />

n QuickSystem features<br />

n Compression lug landing pads (field install up to<br />

1200 Amps, standard feature up to 2000 Amps)<br />

n Standard Mains offer combination overhead and<br />

underground feed up to1200 Amps as well as<br />

dedicated overhead or underground feed up to<br />

2000 Amps<br />

n Skinny Mains offer dedicated feed options, overhead<br />

or underground, in modules 200-1200 Amps<br />

n 750kcmil AL wire options<br />

n 65K AIC standard, 100K AIC available for all models<br />

n Removable blank bottom endwall<br />

n Externally accessible breaker handle with padlock<br />

capability<br />

n Broad ampacity ratings up to 2000 Amps with nonstandard<br />

amperages available (such as 700, 900, etc.)<br />

n Field installable shunt trips<br />

n DAS blue light models available in amperages of<br />

1200-1600<br />

Standard and Skinny Circuit Breaker Mains Quick Reference<br />

n 200-2000A module rating<br />

n 1200A horizontal bus rating<br />

n UL Standard # UL67<br />

n UL file # E27100<br />

n AIC rating (65k and 100k)<br />

n Voltage:<br />

– Single phase 120/240V AC max<br />

– Three phase 240V AC max<br />

n All swing latches and rivets are stainless steel<br />

n NEMA 3R rated<br />

n G90 galvanized steel<br />

n ANSI 61 paint<br />

3-14<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Power Mod<br />

Revised on 08/31/20<br />

Type WB Standard Circuit Breaker Mains<br />

Suitable for use as service equipment.<br />

Bonding means may be removed for nonservice<br />

entrance equipment applications.<br />

Lugs are NOT included<br />

on 1400A-2000A<br />

standard breaker main<br />

modules and must be<br />

ordered separately.<br />

Refer to pages 3-129–<br />

3-130 for lug size<br />

options.<br />

Standard Mains - Single Phase<br />

Thermal magnetic circuit breaker service entrance modules: 1-phase, 3-wire SN, 120/240V AC<br />

Catalog Catalog Catalog No.<br />

(65k AIC) c (100k AIC) b c Blank Endwall<br />

number number (65k AIC)<br />

Catalog No.<br />

(100k AIC)<br />

Blank Endwall<br />

Amp.<br />

rating<br />

Service<br />

feed<br />

Breaker<br />

type Dimensions (inches) a<br />

Height Width Depth<br />

Factory installed<br />

line side connections<br />

WB1200C b WB1200CU WB1200CNH WB1200CUNH 200 OH/UG JXD6 39.19 15.20 11.03<br />

(2) 3/0-500 kcmil CU<br />

(2 )4/0-500 kcmil AL<br />

Knockout<br />

Diagram<br />

WB1250C b WB1250CU WB1250CNH WB1250CUNH 250 OH/UG JXD6 39.19 15.20 11.03<br />

(2) 3/0-500 kcmil CU<br />

(2 )4/0-500 kcmil AL<br />

WB1300C b WB1300CU WB1300CNH WB1300CUNH 300 OH/UG JXD6 39.19 15.20 11.03<br />

(2) 3/0-500 kcmil CU<br />

(2 )4/0-500 kcmil AL<br />

WB1350C b WB1350CU WB1350CNH WB1350CUNH 350 OH/UG JXD6 39.19 15.20 11.03<br />

(2) 3/0-500 kcmil CU<br />

(2 )4/0-500 kcmil AL<br />

WB1400C WB1400CU WB1400CNH WB1400CUNH 400 OH/UG JXD6 39.19 15.20 11.03<br />

(2) 3/0-500 kcmil CU<br />

(2 )4/0-500 kcmil AL<br />

KB-1<br />

WB1450C b WB1450CU WB1450CNH WB1450CUNH 450 OH/UG LXD6 39.19 15.20 11.03<br />

(2) 3/0-500 kcmil CU<br />

(2 )4/0-500 kcmil AL<br />

WB1500C b WB1500CU WB1500CNH WB1500CUNH 500 OH/UG LXD6 39.19 15.20 11.03<br />

(2) 3/0-500 kcmil CU<br />

(2 )4/0-500 kcmil AL<br />

WB1600C WB1600CU WB1600CNH WB1600CUNH 600 OH/UG LXD6 39.19 15.20 11.03<br />

(2) 3/0-500 kcmil CU<br />

(2 )4/0-500 kcmil AL<br />

WB1700C b WB1700CU WB1700CNH WB1700CUNH 700 OH/UG MXD6 61.19 24.19 11.03 (3) 1/0-500 kcmil<br />

WB1800C WB1800CU WB1800CNH WB1800CUNH 800 OH/UG MXD6 61.19 24.19 11.03 (3) 1/0-500 kcmil<br />

KB-2<br />

WB1900C b WB1900CU WB1900CNH WB1900CUNH 900 OH/UG NXD6 61.19 24.19 11.03 (4) 1/0-500 kcmil<br />

WB11000C WB11000CU WB11000CNH WB11000CUNH 1000 OH/UG NXD6 61.19 24.19 11.03 (4) 1/0-500 kcmil KB-3<br />

WB11200C WB11200CU WB11200CNH WB11200CUNH 1200 OH/UG NXD6 61.19 24.19 11.03 (4) 1/0-500 kcmil<br />

WB11400T bd WB11400TU d WB11400TNH WB11400TUNH<br />

OH PXD6 72.06 31.34 14.66<br />

KB-4<br />

1400<br />

WB11400B bd WB11400BU d — — UG PXD6 72.06 31.34 14.66 KB-5<br />

WB11600T d WB11600TU d WB11600TNH WB11600TUNH<br />

OH PXD6 72.06 31.34 14.66<br />

1600<br />

3 Sets of 2 Studs<br />

KB-4<br />

WB11600B d WB11600BU d — — UG PXD6 72.06 31.34 14.66<br />

KB-5<br />

WB11800B bd WB11800BU d — —<br />

UG RXD6 72.06 31.34 14.66<br />

1800<br />

WB11800W WB11800WU WB11800WNH WB11800WUNH OH/UG RXD6 72.06 50.56 14.66<br />

(lugs not included)<br />

KB-6<br />

WB12000B d WB12000BU d — —<br />

UG RXD6 72.06 31.34 14.66 KB-5<br />

2000<br />

WB12000W bd WB12000WU d WB12000WNH WB12000WUNH OH/UG RXD6 72.06 50.56 14.66 KB-6<br />

DAS electronic circuit breaker service entrance modules with blue light maintanance mode: 1-phase, 3 wire SN, 120/240V AC<br />

Catalog Catalog Catalog No.<br />

(65k AIC) c (100k AIC) b c Blank Endwall<br />

number number (65k AIC)<br />

Catalog No.<br />

(100k AIC)<br />

Blank Endwall<br />

Amp.<br />

rating<br />

Service<br />

feed<br />

Breaker<br />

type f Dimensions (inches) a<br />

Height Width Depth<br />

Factory installed<br />

line side connections<br />

WBM11200C WBM11200CU WBM11200CNH WBM11200CUNH 1200 OH/UG SND6 61.19 24.19 11.03 (4) 1/0-500 kcmil KB-3<br />

WBM11400T WBM11400T WBM11400TNH WBM11400TUNH 1400 OH SPD6 72.06 31.34 14.66<br />

KB-4<br />

WBM11400B WBM11400B — — 1400 UG SPD6 72.06 31.34 14.66 KB-5<br />

WBM11600T WBM11600T WBM11600TNH WBM11600TUNH 1600 OH SPD6 72.06 31.34 14.66<br />

3 Sets of 2 Studs<br />

KB-4<br />

WBM11600B WBM11600B — — 1600 UG SPD6 72.06 31.34 14.66 KB-5<br />

WBM11800B WBM11800BU — — 1800 UG RXD6 72.06 31.34 14.66 KB-5<br />

WBM11800W WBM11800WU WBM11800WNH WBM11800WUNH 1800 OH/UG RXD6 72.06 50.56 14.66<br />

(lugs not included)<br />

KB-6<br />

WBM12000B WBM12000BU — — 2000 UG RXD6 72.06 31.34 14.66 KB-5<br />

WBM12000W WBM12000WU WBM12000WNH WBM12000WUNH 2000 OH/UG RXD6 72.06 50.56 14.66 KB-6<br />

Knockout<br />

Diagram<br />

3 METER<br />

CENTERS<br />

a Dimensions shown are representative of outside box<br />

dimensions and do not include allowances for mounting<br />

bumps, endwalls, covers, hubs, or hardware protrusions.<br />

Dimensions are subject to change.<br />

b Additional lead time required. Contact sales office for<br />

details. 100K and non-standard amperage modules.<br />

c Factory installed lugs standard on 200-1200A standard<br />

breaker main modules. Additional lug kit options available<br />

for 750 conductor size. Field installable compression lug<br />

landing pad also available. NEMA 2-stud compression lugs<br />

must be installed by user or utility. Lugs NOT included<br />

on 1400A-2000A standard breaker main modules and<br />

must be ordered separately.<br />

d 1200 amp maximum feed per side-must be used as a<br />

center fed main.<br />

e All breakers have a non-interchangeable trip unit.<br />

f 1800 amp and 2000 amp units utilize CT's and Relays to<br />

operated in Maintenance Mode.<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-15


Power Mod<br />

Revised on 08/31/20<br />

Type WB Standard Circuit Breaker Mains<br />

3<br />

METER<br />

CENTERS<br />

Factory installed lugs are standard on 200-1200A standard breaker<br />

main modules. Additional lug kit options are available for 750<br />

conductor size. Refer to pages 3-129 – 3-130 for lug kit options on<br />

200-1200A standard main breakers. In addition, a field installable<br />

compression lug landing pad is also available. Refer to page<br />

3-132 for lug landing pad options. NEMA 2-stud compression<br />

lugs must be installed by user or utility.<br />

Suitable for use as service equipment. Bonding means may be<br />

removed for non-service entrance equipment applications.<br />

Standard Mains – Three Phase<br />

Thermal magnetic circuit breaker service entrance modules: 3-phase, 4-wire SN, 240V AC max<br />

Catalog Catalog Catalog No.<br />

(65k AIC) c (100k AIC) b c Blank Endwall<br />

number number (65k AIC)<br />

Catalog No.<br />

(100k AIC)<br />

Blank Endwall<br />

Dimensions<br />

(inches) a<br />

Height Width Depth<br />

Amp.<br />

rating<br />

Service<br />

feed<br />

Breaker<br />

type <br />

Factory installed<br />

line side connections<br />

Knockout<br />

Diagram<br />

WB3200C b WB3200CU WB3200CNH WB3200CUNH 200 OH/UG JXD6 39.19 15.20 11.03<br />

(2) 3/0-500 kcmil CU<br />

(2 )4/0-500 kcmil AL<br />

WB3250C b WB3250CU WB3250CNH WB3250CUNH 250 OH/UG JXD6 39.19 15.20 11.03<br />

(2) 3/0-500 kcmil CU<br />

(2 )4/0-500 kcmil AL<br />

WB3300C b WB3300CU WB3300CNH WB3300CUNH 300 OH/UG JXD6 39.19 15.20 11.03<br />

(2) 3/0-500 kcmil CU<br />

(2 )4/0-500 kcmil AL<br />

WB3350C b WB3350CU WB3350CNH WB3350CUNH 350 OH/UG JXD6 39.19 15.20 11.03<br />

(2) 3/0-500 kcmil CU<br />

(2 )4/0-500 kcmil AL<br />

WB3400C WB3400CU WB3400CNH WB3400CUNH 400 OH/UG JXD6 39.19 15.20 11.03<br />

(2) 3/0-500 kcmil CU<br />

(2 )4/0-500 kcmil AL<br />

KB-1<br />

WB3450C b WB3450CU WB3450CNH WB3450CUNH 450 OH/UG LXD6 39.19 15.20 11.03<br />

(2) 3/0-500 kcmil CU<br />

(2 )4/0-500 kcmil AL<br />

WB3500C b WB3500CU WB3500CNH WB3500CUNH 500 OH/UG LXD6 39.19 15.20 11.03<br />

(2) 3/0-500 kcmil CU<br />

(2 )4/0-500 kcmil AL<br />

WB3600C WB3600CU WB3600CNH WB3600CUNH 600 OH/UG LXD6 39.19 15.20 11.03<br />

(2) 3/0-500 kcmil CU<br />

(2 )4/0-500 kcmil AL<br />

WB3700C b WB3700CU WB3700CNH WB3700CUNH 700 OH/UG MXD6 61.19 24.19 11.03 (3) 1/0-500 kcmil<br />

WB3800C WB3800CU WB3800CNH WB3800CUNH 800 OH/UG MXD6 61.19 24.19 11.03 (3) 1/0-500 kcmil<br />

KB-2<br />

WB3900C b WB3900CU WB3900CNH WB3900CUNH 900 OH/UG NXD6 61.19 24.19 11.03 (4) 1/0-500 kcmil<br />

WB31000C WB31000CU WB31000CNH WB31000CUNH 1000 OH/UG NXD6 61.19 24.19 11.03 (4) 1/0-500 kcmil KB-3<br />

WB31200C WB31200CU WB31200CNH WB31200CUNH 1200 OH/UG NXD6 61.19 24.19 11.03 (4) 1/0-500 kcmil<br />

WB31400T bd WB31400TU d WB31400TNH WB31400TUNH<br />

1400 OH PXD6 72.06 31.34 14.66 KB-4<br />

WB31400B bd WB31400BU d — — UG PXD6 72.06 31.34 14.66 KB-5<br />

WB31600T d WB31600TU d WB31600TNH WB31600TUNH<br />

OH PXD6 72.06 31.34 14.66<br />

1600 3 Sets of 2 Studs<br />

KB-4<br />

WB31600B d WB31600BU d — — UG PXD6 72.06 31.34 14.66<br />

KB-5<br />

WB31800B bd WB31800BU d — —<br />

UG RXD6 72.06 31.34 14.66<br />

1800<br />

WB31800W WB31800WU WB31800WNH WB31800WUNH OH/UG RXD6 72.06 50.56 14.66<br />

(lugs not included)<br />

KB-6<br />

WB32000B cd WB32000BU d — —<br />

UG RXD6 72.06 31.34 14.66 KB-5<br />

2000<br />

WB32000W bd WB32000WU d WB32000WNH WB32000WUNH OH/UG RXD6 72.06 50.56 14.66 KB-6<br />

DAS electronic circuit breaker service entrance modules with blue light maintanance mode: 3-phase, 4 wire SN, 240V AC max<br />

Catalog Catalog Catalog No.<br />

(65k AIC) c (100k AIC) b c Blank Endwall<br />

number number (65k AIC)<br />

Catalog No.<br />

(100k AIC)<br />

Blank Endwall<br />

Amp.<br />

rating<br />

Service<br />

feed<br />

Lugs are NOT included<br />

on 1400A-2000A<br />

standard breaker main<br />

modules and must be<br />

ordered separately.<br />

Refer to pages 3-129–<br />

3-130 for lug size<br />

options.<br />

Breaker<br />

type f<br />

Dimensions<br />

(inches) a<br />

Factory installed<br />

line side connections<br />

Knockout<br />

Diagram<br />

Height Width Depth<br />

WBM31200C WBM31200CU WBM31200CNH WBM31200CUNH 1200 OH/UG SND6 61.19 24.19 11.03 (4) 1/0-500 kcmil KB-3<br />

WBM31400T WBM31400TU WBM31400TNH WBM31400TUNH 1400 OH SPD6 72.06 31.34 14.66<br />

KB-4<br />

WBM31400B WBM31400BU — — 1400 UG SPD6 72.06 31.34 14.66 KB-5<br />

WBM31600T<br />

WBM31600B<br />

WBM31600TU<br />

WBM31600BU<br />

WBM31600TNH<br />

—<br />

WBM31600TUNH<br />

—<br />

1600<br />

1600<br />

OH<br />

UG<br />

SPD6<br />

SPD6<br />

72.06<br />

72.06<br />

31.34<br />

31.34<br />

14.66<br />

14.66<br />

3 Sets of 2 Studs<br />

KB-4<br />

KB-5<br />

WBM31800B WBM31800BU — — 1800 UG RXD6 72.06 31.34 14.66 KB-5<br />

WBM31800W WBM31800WU WBM31800WNH WBM31800WUNH 1800 OH/UG RXD6 72.06 50.56 14.66<br />

(lugs not included)<br />

KB-6<br />

WBM32000B WBM32000BU — — 2000 UG RXD6 72.06 31.34 14.66 KB-5<br />

WBM32000W WBM32000WU WBM32000WNH WBM32000WUNH 2000 OH/UG RXD6 72.06 50.56 14.66 KB-6<br />

a Dimensions shown are representative of outside box<br />

dimensions and do not include allowances for mounting<br />

bumps, endwalls, covers, hubs, or hardware protrusions.<br />

Dimensions are subject to change.<br />

b Additional lead time required. Contact sales office for<br />

details. 100K and non-standard amperage modules.<br />

c Factory installed lugs standard on 200-1200A standard<br />

breaker main modules. Additional lug kit options available<br />

for 750 conductor size. Field installable compression lug<br />

landing pad also available. NEMA 2-stud compression lugs<br />

must be installed by user or utility. Lugs NOT included<br />

on 1400A-2000A standard breaker main modules and<br />

must be ordered separately.<br />

d 1200 amp maximum feed per side-must be used as a<br />

center fed main.<br />

e All breakers have a non-interchangeable trip unit.<br />

f 1800 amp and 2000 amp units utilize CT's and Relays to<br />

operated in Maintenance Mode.<br />

3-16<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Power Mod<br />

Revised on 10/31/19<br />

Type WB Skinny Circuit Breaker Mains with Dedicated Feed Direction<br />

Suitable for use as service equipment.<br />

Bonding means may be removed for nonservice<br />

entrance equipment applications.<br />

Skinny Mains are narrower than<br />

standard WB mains because they<br />

require a predetermined dedicated feed<br />

direction; either top feed or bottom feed.<br />

This direction must be known prior to<br />

selecting the unit. If feed direction is<br />

unknown, use a combination feed unit<br />

from previous pages.<br />

Skinny Mains – Single Phase<br />

Skinny thermal magnetic circuit breaker service entrance modules: 1-phase, 3-wire SN, 120/240V AC c<br />

Catalog<br />

number<br />

(65k AIC)<br />

Catalog No.<br />

Catalog<br />

(100k AIC) b Blank Endwall<br />

number (65k AIC)<br />

Catalog No.<br />

(100k AIC)<br />

Blank Endwall b<br />

Amp.<br />

rating<br />

Service<br />

feed<br />

Dimensions (inches) a<br />

Breaker<br />

Factory installed<br />

type d Height Width Depth line side connections e<br />

WB1200T WB1200TU WB1200TNH WB1200TUNH 200 Top JXD6 45.19 9.56 11 (2) 3/0-500 kcmil CU<br />

WB1200B WB1200BU — — 200 Bottom JXD6 45.19 9.56 11 (2) 4/0-500 kcmil AL<br />

WB1250T WB1250TU WB1250TNH WB1250TUNH 250 Top JXD6 45.19 9.56 11 (2) 3/0-500 kcmil CU<br />

WB1250B WB1250BU — — 250 Bottom JXD6 45.19 9.56 11 (2) 4/0-500 kcmil AL<br />

WB1300T WB1300TU WB1300TNH WB1300TUNH 300 Top JXD6 45.19 9.56 11 (2) 3/0-500 kcmil CU<br />

WB1300B WB1300BU — — 300 Bottom JXD6 45.19 9.56 11 (2) 4/0-500 kcmil AL<br />

WB1350T WB1350TU WB1350TNH WB1350TUNH 350 Top JXD6 45.19 9.56 11 (2) 3/0-500 kcmil CU<br />

WB1350B WB1350BU — — 350 Bottom JXD6 45.19 9.56 11 (2) 4/0-500 kcmil AL<br />

WB1400T WB1400TU WB1400TNH WB1400TUNH 400 Top JXD6 45.19 9.56 11 (2) 3/0-500 kcmil CU<br />

WB1400B WB1400BU — — 400 Bottom JXD6 45.19 9.56 11 (2) 4/0-500 kcmil AL<br />

WB1450T WB1450TU WB1450TNH WB1450TUNH 450 Top LXD6 45.19 9.56 11 (2) 3/0-500 kcmil CU<br />

WB1450B WB1450BU — — 450 Bottom LXD6 45.19 9.56 11 (2) 4/0-500 kcmil AL<br />

WB1500T WB1500TU WB1500TNH WB1500TUNH 500 Top LXD6 45.19 9.56 11 (2) 3/0-500 kcmil CU<br />

WB1500B WB1500BU — — 500 Bottom LXD6 45.19 9.56 11 (2) 4/0-500 kcmil AL<br />

WB1600T WB1600TU WB1600TNH WB1600TUNH 600 Top LXD6 45.19 9.56 11 (2) 3/0-500 kcmil CU<br />

WB1600B WB1600BU — — 600 Bottom LXD6 45.19 9.56 11 (2) 4/0-500 kcmil AL<br />

WB1700T WB1700TU WB1700TNH WB1700TUNH 700 Top MXD6 58.69 11.06 13.25<br />

WB1700B WB1700BU — — 700 Bottom MXD6 58.69 11.06 13.25<br />

WB1800T WB1800TU WB1800TNH WB1800TUNH 800 Top MXD6 58.69 11.06 13.25<br />

(3) 1/0-500 kcmil<br />

WB1800B WB1800BU — — 800 Bottom MXD6 58.69 11.06 13.25<br />

WB1900T WB1900TU WB1900TNH WB1900TUNH 900 Top NXD6 58.69 11.06 13.25<br />

WB1900B WB1900BU — — 900 Bottom NXD6 58.69 11.06 13.25<br />

WB11000T WB11000TU WB11000TNH WB11000TUNH 1000 Top NXD6 58.69 11.06 13.25<br />

WB11000B WB11000BU — — 1000 Bottom NXD6 58.69 11.06 13.25<br />

(4) 1/0-500 kcmil<br />

WB11200T WB11200TU WB11200TNH WB11200TUNH 1200 Top NXD6 58.69 11.06 13.25<br />

WB11200B WB11200BU — — 1200 Bottom NXD6 58.69 11.06 13.25<br />

Skinny DAS electronic circuit breaker service entrance modules with blue light: 1-phase, 3 wire SN, 120/240V AC c<br />

Catalog<br />

number<br />

(65k AIC)<br />

Catalog No.<br />

Catalog<br />

(100k AIC) b Blank Endwall<br />

number (65k AIC)<br />

Catalog No.<br />

(100k AIC)<br />

Blank Endwall b<br />

Dimensions (inches) a<br />

Amp. Service Breaker<br />

Factory installed<br />

rating feed type d Height Width Depth line side connections e<br />

WBM11200T WBM11200TU WBM11200TNH WBM11200TUNH 1200 Top SND6 58.69 11.06 13.25 (4) 1/0-500 kcmil<br />

WBM11200B WBM11200BU — — 1200 Top SND6 58.69 11.06 13.25 (4) 1/0-500 kcmil<br />

3 METER<br />

CENTERS<br />

Caution: Feed direction is not changeable in the field. Only select a Skinny Main if feed direction is<br />

certain. If feed direction is not certain, use combination feed mains found on pages 3-15 – 3-16.<br />

a Dimensions shown are representative of outside box<br />

dimensions and do not include allowances for mounting<br />

bumps, endwalls, covers, hubs, or hardware protrusions.<br />

Dimensions are subject to change.<br />

b Additional lead time required. Contact sales office for<br />

details. 100K and non-standard amperage modules.<br />

c Factory installed lugs standard on 200-1200A standard<br />

breaker main modules. Additional lug kit options available<br />

for 750 conductor size.<br />

d All breakers have a non-interchangeable trip unit.<br />

e Skinny Mains are non-compatible with the lug landing<br />

pads LLP600 and LLP1200.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-17


Power Mod<br />

Revised on 10/31/19<br />

Type WB Skinny Circuit Breaker Mains with Dedicated Feed Direction<br />

Suitable for use as service equipment.<br />

Bonding means may be removed for nonservice<br />

entrance equipment applications.<br />

Skinny Mains are narrower than<br />

standard WB mains because they<br />

require a predetermined dedicated feed<br />

direction; either top feed or bottom feed.<br />

This direction must be known prior to<br />

selecting the unit. If feed direction is<br />

unknown, use a combination feed unit<br />

from previous pages.<br />

3<br />

METER<br />

CENTERS<br />

Skinny Mains – Three Phase<br />

Skinny thermal magnetic circuit breaker service entrance modules: 3-phase, 4-wire SN, 240V AC max c<br />

Catalog<br />

number<br />

(65k AIC)<br />

Catalog No.<br />

Catalog<br />

(100k AIC) b Blank Endwall<br />

number (65k AIC)<br />

Catalog No.<br />

(100k AIC)<br />

Blank Endwall b<br />

Amp.<br />

rating<br />

Service<br />

feed<br />

Dimensions (inches) a<br />

Breaker<br />

Factory installed<br />

type d Height Width Depth line side connections e<br />

WB3200T WB3200TU WB3200TNH WB3200TUNH 200 Top JXD6 45.19 9.56 11 (2) 3/0-500 kcmil CU<br />

WB3200B WB3200BU — — 200 Bottom JXD6 45.19 9.56 11 (2) 4/0-500 kcmil AL<br />

WB3250T WB3250TU WB3250TNH WB3250TUNH 250 Top JXD6 45.19 9.56 11 (2) 3/0-500 kcmil CU<br />

WB3250B WB3250BU — — 250 Bottom JXD6 45.19 9.56 11 (2) 4/0-500 kcmil AL<br />

WB3300T WB3300TU WB3300TNH WB3300TUNH 300 Top JXD6 45.19 9.56 11 (2) 3/0-500 kcmil CU<br />

WB3300B WB3300BU — — 300 Bottom JXD6 45.19 9.56 11 (2) 4/0-500 kcmil AL<br />

WB3350T WB3350TU WB3350TNH WB3350TUNH 350 Top JXD6 45.19 9.56 11 (2) 3/0-500 kcmil CU<br />

WB3350B WB3350BU — — 350 Bottom JXD6 45.19 9.56 11 (2) 4/0-500 kcmil AL<br />

WB3400T WB3400TU WB3400TNH WB3400TUNH 400 Top JXD6 45.19 9.56 11 (2) 3/0-500 kcmil CU<br />

WB3400B WB3400BU — — 400 Bottom JXD6 45.19 9.56 11 (2) 4/0-500 kcmil AL<br />

WB3450T WB3450TU WB3450TNH WB3450TUNH 450 Top LXD6 45.19 9.56 11 (2) 3/0-500 kcmil CU<br />

WB3450B WB3450BU — — 450 Bottom LXD6 45.19 9.56 11 (2) 4/0-500 kcmil AL<br />

WB3500T WB3500TU WB3500TNH WB3500TUNH 500 Top LXD6 45.19 9.56 11 (2) 3/0-500 kcmil CU<br />

WB3500B WB3500BU — — 500 Bottom LXD6 45.19 9.56 11 (2) 4/0-500 kcmil AL<br />

WB3600T WB3600TU WB3600TNH WB3600TUNH 600 Top LXD6 45.19 9.56 11 (2) 3/0-500 kcmil CU<br />

WB3600B WB3600BU — — 600 Bottom LXD6 45.19 9.56 11 (2) 4/0-500 kcmil AL<br />

WB3700T WB3700TU WB3700TNH WB3700TUNH 700 Top MXD6 58.69 11.06 13.25<br />

WB3700B WB3700BU — — 700 Bottom MXD6 58.69 11.06 13.25<br />

WB3800T WB3800TU WB3800TNH WB3800TUNH 800 Top MXD6 58.69 11.06 13.25<br />

(3) 1/0-500 kcmil<br />

WB3800B WB3800BU — — 800 Bottom MXD6 58.69 11.06 13.25<br />

WB3900T WB3900TU WB3900TNH WB3900TUNH 900 Top NXD6 58.69 11.06 13.25<br />

WB3900B WB3900BU — — 900 Bottom NXD6 58.69 11.06 13.25<br />

WB31000T WB31000TU WB31000TNH WB31000TUNH 1000 Top NXD6 58.69 11.06 13.25<br />

WB31000B WB31000BU — — 1000 Bottom NXD6 58.69 11.06 13.25<br />

(4) 1/0-500 kcmil<br />

WB31200T WB31200TU WB31200TNH WB31200TUNH 1200 Top NXD6 58.69 11.06 13.25<br />

WB31200B WB31200BU — — 1200 Bottom NXD6 58.69 11.06 13.25<br />

Skinny DAS electronic circuit breaker service entrance modules with blue light: 3-phase, 4 wire SN, 240V AC max c<br />

Catalog<br />

number<br />

(65k AIC)<br />

Catalog No.<br />

Catalog<br />

(100k AIC) b Blank Endwall<br />

number (65k AIC)<br />

Catalog No.<br />

(100k AIC)<br />

Blank Endwall b<br />

Amp.<br />

rating<br />

Service<br />

feed<br />

Breaker<br />

type d Height Width Depth<br />

Factory installed<br />

line side connections e<br />

WBM31200T WBM31200TU WBM31200TNH WBM31200TUNH 1200 Top SND6 58.69 11.06 13.25<br />

WBM31200B WBM31200BU — — 1200 Bottom SND6 58.69 11.06 13.25<br />

(4) 1/0-500 kcmil<br />

Caution: Feed direction is not changeable in the field. Only select a Skinny Main if feed direction is<br />

certain. If feed direction is not certain, use combination feed mains found on pages 3-15 – 3-16.<br />

a Dimensions shown are representative of outside box<br />

dimensions and do not include allowances for mounting<br />

bumps, endwalls, covers, hubs, or hardware protrusions.<br />

Dimensions are subject to change.<br />

b Additional lead time required. Contact sales office for<br />

details. 100K and non-standard amperage modules.<br />

c Factory installed lugs standard on 200-1200A standard<br />

breaker main modules. Additional lug kit options available<br />

for 750 conductor size.<br />

d All breakers have a non-interchangeable trip unit.<br />

e Skinny Mains are non-compatible with the lug landing<br />

pads LLP600 and LLP1200.<br />

3-18<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Type WB Standard Circuit Breaker Mains Knockout Diagrams<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

3 METER<br />

CENTERS<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

KB-1<br />

KB-2<br />

KB-3<br />

WB3200XX<br />

WB3250XX<br />

WB3300XX<br />

WB3350XX<br />

WB3400XX<br />

WB3450XX<br />

WB3500XX<br />

WB3600XX<br />

WB1200XX<br />

WB1250XX<br />

WB1300XX<br />

WB1350XX<br />

WB1400XX<br />

WB1450XX<br />

WB1500XX<br />

WB1600XX<br />

WB3700XX<br />

WB3800XX<br />

WB1700XX<br />

WB1800XX<br />

WB3900XX<br />

WB31000XX<br />

WB31200XX<br />

WB1900XX<br />

WB11000XX<br />

WB11200XX<br />

31-11/32<br />

31-11/32<br />

6<br />

3<br />

14-21/32<br />

6 TYPE "HD" 4" MAX<br />

HUB OPENINGS<br />

FACTORY INSTALLED<br />

COVER PLATES<br />

14-21/32<br />

18-5/32<br />

27-3/8 TO<br />

PHASE<br />

STUDS<br />

29-3/8 TO<br />

NEUTRAL<br />

STUDS<br />

}<br />

1-3/4 NEMA<br />

STUD SPACING<br />

72-1/16<br />

1-3/4 NEMA<br />

STUD SPACING<br />

72-1/16<br />

46-21/32 TO<br />

BOTTOM OF<br />

QUICK ROLL<br />

BRACKET<br />

35-1/32 TO<br />

CROSS BUS<br />

CENTER<br />

48-21/32 TO<br />

BOTTOM OF<br />

QUICK ROLL<br />

BRACKET<br />

37-1/32 TO<br />

CROSS BUS<br />

CENTER<br />

29-3/8 TO<br />

NEUTRAL<br />

STUDS<br />

}<br />

27-3/8 TO<br />

PHASE<br />

STUDS<br />

28-5/8<br />

REMOVABLE<br />

BOTTOM<br />

ENDWALL<br />

OPENING<br />

11-29/32<br />

WB31400TX<br />

WB31600TX<br />

WB32000TX<br />

KB-4<br />

WB11400TX<br />

WB11600TX<br />

WB12000TX<br />

WB31400BX<br />

WB31600BX<br />

WB31800BX<br />

WB32000BX<br />

KB-5<br />

WB11400BX<br />

WB11600BX<br />

WB11800BX<br />

WB12000BX<br />

WB12000W<br />

WB12000WU<br />

WB11800W<br />

WB11800WU<br />

KB-6<br />

WB31800W<br />

WB31800WU<br />

WB32000W<br />

WB32000WU<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-19


Power Mod<br />

Revised on 06/30/19<br />

Type WEB Circuit Breaker – Pullbox Combinations<br />

Circuit Breaker – Pullbox Combinations<br />

EUSERC – compliant breaker – pullbox combination<br />

modules (type WEB) offer EUSERC compatibility, a<br />

wider range of lug options, and extra space for pulling<br />

in conductors.<br />

3<br />

METER<br />

CENTERS<br />

Features include:<br />

n QuickSystem features<br />

n NEMA 2-stud lug mounting pattern<br />

n 750 kcmil AL wire options<br />

n 65K AIC standard, 100K AIC available for all models<br />

n Removable blank bottom endwall<br />

n Externally accessible breaker handle with padlock<br />

capability<br />

n Field installable shunt trips<br />

n Large removable ground wire trough with generous<br />

space for grounding conductors<br />

n DAS blue light models available in 1200A<br />

Circuit Breaker-Pullbox Combinations Quick Reference<br />

n 200-1200A module rating<br />

n 1200A horizontal bus rating<br />

n UL standard # UL67<br />

n UL file # E27100<br />

n AIC rating (65k and 100k)<br />

n Voltage<br />

– Single phase 120/240V AC max<br />

– Three phase 240V AC max<br />

n All swing latches and rivets are stainless steel<br />

n NEMA 3R rated<br />

n G90 galvanized steel<br />

n ANSI 61 paint<br />

n EUSERC drawing number 347<br />

3-20<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 10/31/19<br />

Type WEB Circuit Breaker – Pullbox Combinations<br />

Suitable for use as service equipment.<br />

Bonding means may be removed for nonservice<br />

entrance equipment applications.<br />

Lugs are NOT included<br />

and must be ordered<br />

separately.<br />

Refer to pages 3-129–<br />

3-130 for lug size<br />

options.<br />

Thermal magnetic combination circuit breaker and pullbox modules:<br />

1-phase, 3-wire SN, 120/240V AC max, meets EUSERC requirements<br />

3 METER<br />

CENTERS<br />

Catalog<br />

number<br />

(65k AIC)<br />

Catalog<br />

number<br />

Ampere<br />

(100k AIC) b rating<br />

Service<br />

feed<br />

Breaker Dimensions (inches) a Line side c<br />

connections<br />

type d Height Width Depth (lugs not included)<br />

Knockout<br />

Diagram<br />

WEB1200B b WEB1200BU 200 UG JXD6 54.88 28.28 13.06<br />

WEB1250B b WEB1250BU 250 UG JXD6 54.88 28.28 13.06<br />

WEB1300B b WEB1300BU 300 UG JXD6 54.88 28.28 13.06<br />

WEB1350B b WEB1350BU 350 UG JXD6 54.88 28.28 13.06<br />

1 set of 2 studs<br />

EB-1<br />

WEB1400B WEB1400BU 400 UG JXD6 54.88 28.28 13.06<br />

WEB1500B b WEB1500BU 500 UG LXD6 54.88 28.88 13.06 2 sets of 2 studs<br />

WEB1600B WEB1600BU 600 UG LXD6 54.88 28.28 13.06<br />

EB-2<br />

WEB1700B b WEB1700BU 700 UG MXD6 59.34 34.22 12.47<br />

WEB1800B WEB1800BU 800 UG MXD6 59.34 34.22 12.47<br />

WEB1900B b WEB1900BU 900 UG NXD6 59.34 34.22 12.47<br />

WEB11000B WEB11000BU 1000 UG NXD6 59.34 34.22 12.47<br />

3 sets of 2 studs<br />

EB-3<br />

WEB11200B WEB11200BU 1200 UG NXD6 59.34 34.22 12.47<br />

DAS electronic combination circuit breaker and pullbox modules with blue light maintanance mode:<br />

1-phase, 3-wire SN, 120/240V AC max, meets EUSERC requirements<br />

Catalog<br />

number<br />

(65k AIC)<br />

Catalog<br />

number<br />

Ampere<br />

(100k AIC) b rating<br />

Service<br />

feed<br />

Dimensions (inches)<br />

a Line sidec<br />

Breaker<br />

connections<br />

type d Height Width Depth (lugs not included)<br />

WEBM11200B WEBM11200BU 1200 UG SND6 59.34 34.22 12.47<br />

3 sets of 2 studs<br />

Knockout<br />

Diagram<br />

EB-3<br />

a Dimensions shown are representative of outside<br />

box dimensions and do not include allowances for<br />

mounting bumps, endwalls, covers, hubs, or hardware<br />

protrusions. Dimensions are subject to change.<br />

b Additional lead time required. Contact sales office for<br />

details. Non-standard modules<br />

c Lugs not included. Refer to page 3-129–3-130 for lug<br />

size options. 750 conductor size available. NEMA 2-stud<br />

compression lugs must be installed by user or utility.<br />

d All breakers have a non-interchangeable trip unit.<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-21


Power Mod<br />

Revised on 10/31/19<br />

Type WEB Circuit Breaker - Pullbox Combinations<br />

Suitable for use as service equipment.<br />

Bonding means may be removed for nonservice<br />

entrance equipment applications.<br />

Lugs are NOT included<br />

and must be ordered<br />

separately.<br />

Refer to pages 3-129–<br />

3-130 for lug size<br />

options.<br />

METER<br />

CENTERS<br />

3<br />

Thermal magnetic combination circuit breaker and pullbox modules:<br />

3-phase, 4-wire SN, 240V AC max, meets EUSERC requirements<br />

Catalog<br />

number<br />

(65k AIC)<br />

Catalog<br />

number<br />

Ampere<br />

(100k AIC) b rating<br />

Service<br />

feed<br />

Breaker Dimensions (inches) a Line side c<br />

connections<br />

type d Height Width Depth (lugs not included)<br />

Knockout<br />

Diagram<br />

WEB3200B b WEB3200BU 200 UG JXD6 54.88 28.28 13.06<br />

WEB3250B b WEB3250BU 250 UG JXD6 54.88 28.28 13.06<br />

WEB3300B b WEB3300BU 300 UG JXD6 54.88 28.28 13.06<br />

WEB3350B b WEB3350BU 350 UG JXD6 54.88 28.28 13.06<br />

WEB3400B WEB3400BU 400 UG JXD6 54.88 28.28 13.06<br />

1 set of 2 studs<br />

EB-1<br />

WEB3500B b WEB3500BU 500 UG LXD6 54.88 28.28 13.06 2 sets of 2 studs<br />

WEB3600B WEB3600BU 600 UG LXD6 54.88 28.28 13.06<br />

EB-2<br />

WEB3700B b WEB3700BU 700 UG MXD6 59.34 34.22 12.47<br />

WEB3800B WEB3800BU 800 UG MXD6 59.34 34.22 12.47<br />

WEB3900B b WEB3900BU 900 UG NXD6 59.34 34.22 12.47<br />

WEB31000B WEB31000BU 1000 UG NXD6 59.34 34.22 12.47<br />

WEB31200B WEB31200BU 1200 UG NXD6 59.34 34.22 12.47<br />

3 sets of 2 studs<br />

EB-3<br />

DAS electronic combination circuit breaker and pullbox modules with blue light maintanance mode:<br />

3-phase, 4-wire SN, 240V AC max, meets EUSERC requirements<br />

Catalog<br />

number<br />

(65k AIC)<br />

Catalog<br />

number<br />

Ampere<br />

(100k AIC) b rating<br />

Service<br />

feed<br />

type Height Width Depth (lugs not included)<br />

Breaker<br />

Dimensions (inches) a Line side c<br />

connections<br />

WEBM31200B WEBM31200BU 1200 UG SND6 59.34 34.22 12.47<br />

3 sets of 2 studs<br />

Knockout<br />

Diagram<br />

EB-3<br />

a Dimensions shown are representative of outside<br />

box dimensions and do not include allowances for<br />

mounting bumps, endwalls, covers, hubs, or hardware<br />

protrusions. Dimensions are subject to change.<br />

b Additional lead time required. Contact sales office for<br />

details. Non-standard modules<br />

c Lugs not included. Refer to page 3-129–3-130 for lug<br />

size options. 750 conductor size available. NEMA 2-stud<br />

compression lugs must be installed by user or utility.<br />

d All breakers have a non-interchangeable trip unit.<br />

3-22<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Power Mod<br />

Revised on 12/13/17<br />

Type WEB Circuit Breaker – Pullbox Combinations: Knockout Diagrams<br />

3 METER<br />

CENTERS<br />

WEB1200B<br />

WEB3200B<br />

WEB1250B<br />

WEB3250B<br />

WEB1300B<br />

WEB3300B<br />

WEB1350B<br />

WEB3350B<br />

WEB1400B<br />

WEB3400B<br />

EB-1<br />

WEB1200BU<br />

WEB3200BU<br />

WEB1250BU<br />

WEB3250BU<br />

WEB1300BU<br />

WEB3300BU<br />

WEB1350BU<br />

WEB3350BU<br />

WEB1400BU<br />

WEB3400BU<br />

WEB1500B<br />

WEB1500BU<br />

WEB1600B<br />

WEB1600B<br />

EB-2<br />

WEB3500B<br />

WEB3500BU<br />

WEB3600B<br />

WEB3600BU<br />

34-7/32<br />

12-15/32<br />

32<br />

1-3/4" NEMA<br />

STUD SPACING<br />

}<br />

59-11/32<br />

44-7/8 TO<br />

BOTTOM OF<br />

QUICK ROLL<br />

BRACKET<br />

33-1/4 TO<br />

CROSS BUS<br />

CENTER<br />

26-25/32 TO<br />

PHASE AND<br />

NEUTRAL<br />

STUDS<br />

REMOVABLE<br />

BOTTOM<br />

ENDWALL<br />

OPENING<br />

29-1/8<br />

3/4 KO<br />

8-5/8<br />

EB-3<br />

WEB1700B<br />

WEB3700B<br />

WEB1800B<br />

WEB3800B<br />

WEB1700BU<br />

WEB3700BU<br />

WEB1800BU<br />

WEB3800BU<br />

WEB1900B<br />

WEB1900BU<br />

WEB3900B<br />

WEB3900BU<br />

WEB11000B<br />

WEB11200B<br />

WEB31000B<br />

WEB31200B<br />

WEB11000BU<br />

WEB11200BU<br />

WEB31000BU<br />

WEB31200BU<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-23


Power Mod<br />

Revised on 06/30/19<br />

Type WXB Main Units<br />

Cross Bus Main modules<br />

Cross Bus Main modules (type WXB) offer two<br />

distinct functions: first they can be used to connect<br />

Siemens Sentron Busway to a Power Mod line-up.<br />

Second they can be utilized to offer lower service<br />

sdisconnect ampacities or unique configurations<br />

where an incoming tap box is preferred. See application<br />

pages for examples.<br />

3<br />

METER<br />

CENTERS<br />

Features include:<br />

n QuickSystem features<br />

n Incoming and outgoing bus connections<br />

(right to left or left to right)<br />

n Standardized connection points to Siemens<br />

Sentron Busway<br />

n 65K AIC standard, 100K AIC available for all models<br />

n Externally accessible breaker handle with<br />

padlock capability<br />

n Broad ampacity ratings up to 1200 Amps with<br />

non-standard amperages available (such as 700,<br />

900, etc.)<br />

n Field installable shunt trips<br />

n DAS blue light models available in 1200A"<br />

Circuit Breaker-Pullbox Combinations Quick Reference<br />

n 400-1200A module rating<br />

n 1200A horizontal bus rating<br />

n UL Standard # UL67<br />

n UL file # E27100<br />

n AIC rating (65k and 100k)<br />

n Voltage:<br />

– Single phase 120/240V AC max<br />

–Three phase 240V AC max<br />

n All swing latches and rivets are stainless steel<br />

n NEMA 3R rated<br />

n G90 galvanized steel<br />

n ANSI 61 paint<br />

3-24<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 06/30/19<br />

Type WXB Main Units<br />

Not for use as service equipment.<br />

Connects via<br />

horizontal bussing<br />

only - NO LUGS<br />

Thermal magnetic circuit breaker modules: 1-phase, 3-wire SN, 120/240V AC b<br />

Catalog number<br />

(65k AIC)<br />

Catalog number Ampere<br />

(100k AIC) c rating<br />

Service<br />

Feed<br />

Breaker<br />

Type<br />

Dimensions a<br />

Height Width Depth<br />

Knockout<br />

diagram<br />

WXB1200N WXB1200NU 200 Horizontal Bus JXD6 27.05 15.59 10.82 WXB-1<br />

WXB1250N WXB1250NU 250 Horizontal Bus JXD6 27.05 15.59 10.82<br />

WXB1300N WXB1300NU 300 Horizontal Bus JXD6 27.05 15.59 10.82<br />

WXB1350N WXB1350NU 350 Horizontal Bus JXD6 27.05 15.59 10.82<br />

WXB1400N WXB1400NU 400 Horizontal Bus JXD6 27.05 15.59 10.82<br />

WXB1450N WXB1450NU 450 Horizontal Bus LXD6 27.05 15.59 10.82<br />

WXB1500N WXB1500NU 500 Horizontal Bus LXD6 27.05 15.59 10.82<br />

WXB1600N WXB1600NU 600 Horizontal Bus LXD6 27.05 15.59 10.82<br />

WXB1700N WXB1700NU 700 Horizontal Bus MXD6 36.05 18.13 12.63<br />

WXB1800N WXB1800NU 800 Horizontal Bus MXD6 36.05 18.13 12.63<br />

WXB-2<br />

WXB1900N WXB1900NU 900 Horizontal Bus NXD6 36.05 18.13 12.63<br />

WXB11000N WXB11000NU 1000 Horizontal Bus NXD6 36.05 18.13 12.63<br />

WXB-3<br />

WXB11200N WXB11200NU 1200 Horizontal Bus NXD6 41.06 18.13 12.63 WXB-4<br />

Thermal magnetic circuit breaker modules: 3-phase, 4-wire SN, 240V AC max b<br />

Catalog number<br />

(65k AIC)<br />

Catalog Number Ampere<br />

(100k AIC) c rating<br />

Service<br />

Feed<br />

Breaker<br />

Type<br />

Dimensions a<br />

Height Width Depth<br />

Knockout<br />

diagram<br />

WXB3200N WXB3200NU 200 Horizontal Bus JXD6 27.05 15.59 10.82<br />

WXB3250N WXB3250NU 250 Horizontal Bus JXD6 27.05 15.59 10.82<br />

WXB3300N WXB3300NU 300 Horizontal Bus JXD6 27.05 15.59 10.82<br />

WXB3350N WXB3350NU 350 Horizontal Bus JXD6 27.05 15.59 10.82<br />

WXB-1<br />

WXB3400N WXB3400NU 400 Horizontal Bus JXD6 27.05 15.59 10.82<br />

WXB3450N WXB3450NU 450 Horizontal Bus LXD6 27.05 15.59 10.82<br />

WXB3500N WXB3500NU 500 Horizontal Bus LXD6 27.05 15.59 10.82<br />

WXB3600N WXB3600NU 600 Horizontal Bus LXD6 27.05 15.59 10.82<br />

WXB3700N WXB3700NU 700 Horizontal Bus MXD6 36.05 18.13 12.63<br />

WXB3800N WXB3800NU 800 Horizontal Bus MXD6 36.05 18.13 12.63<br />

WXB-2<br />

WXB3900N WXB3900NU 900 Horizontal Bus NXD6 36.05 18.13 12.63<br />

WXB31000N WXB31000NU 1000 Horizontal Bus NXD6 36.05 18.13 12.63<br />

WXB-3<br />

WXB31200N WXB31200NU 1200 Horizontal Bus NXD6 41.06 18.13 12.63 WXB-4<br />

DAS electronic circuit breaker modules with blue light maintanance mode: 1-phase, 3 wire SN, 120/240V AC b<br />

Catalog number Catalog number<br />

Service<br />

Breaker Dimensions a<br />

Knockout<br />

(65k AIC)<br />

(100k AIC) a Ampere<br />

rating Feed<br />

Type Height Width Depth diagram<br />

WXBM11200N WXBM11200NU 1200 Horizontal bus SND6 41.06 18.13 12.63 WXB-4<br />

DAS electronic circuit breaker modules with blue light maintanance mode: 3-phase, 4 wire SN, 240V AC max b<br />

Catalog number Catalog number<br />

Service<br />

Breaker Dimensions a<br />

Knockout<br />

(65k AIC)<br />

(100k AIC) a Ampere<br />

rating Feed<br />

Type Height Width Depth diagram<br />

WXBM31200N WXBM31200NU 1200 Horizontal bus SND6 41.06 18.13 12.63 WXB-4<br />

3 METER<br />

CENTERS<br />

a Dimensions shown are representative of outside<br />

box dimensions and do not include allowances for<br />

mounting bumps, endwalls, covers, hubs, or hardware<br />

protrusions. Dimensions are subject to change.<br />

b Connects via horizontal bussing only.<br />

c Non Standard item – extended lead time applies<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-25


Power Mod<br />

Revised on 06/30/19<br />

Type WXB Main Units: Knockout Diagrams<br />

3<br />

METER<br />

CENTERS<br />

WXB-1<br />

WXB1200N<br />

WXB1200NU<br />

WXB1250N<br />

WXB1250NU<br />

WXB1300N<br />

WXB1300NU<br />

WXB1350N<br />

WXB1350NU<br />

WXB1400N<br />

WXB1400NU<br />

WXB1450N<br />

WXB1450NU<br />

WXB1500N<br />

WXB1500NU<br />

WXB1600N<br />

WXB1600NU<br />

WXB-1<br />

WXB3200N<br />

WXB3200NU<br />

WXB3250N<br />

WXB3250NU<br />

WXB3300N<br />

WXB3300NU<br />

WXB3350N<br />

WXB3350NU<br />

WXB3400N<br />

WXB3400NU<br />

WXB3450N<br />

WXB3450NU<br />

WXB3500N<br />

WXB3500NU<br />

WXB3600N<br />

WXB3600NU<br />

WXB-2<br />

WXB-2<br />

WXB1700N<br />

WXB1700NU<br />

WXB1800N<br />

WXB1800NU<br />

WXB3700N<br />

WXB3700NU<br />

WXB3800N<br />

WXB3800NU<br />

WXB-3<br />

WXB-3<br />

WXB-4<br />

WXB1900N<br />

WXB1900NU<br />

WXB11000N<br />

WXB11000NU<br />

WXB3900N<br />

WXB3900NU<br />

WXB31000N<br />

WXB31000NU<br />

WXB-4<br />

WXB11200N<br />

WXB11200NU<br />

WXBM11200N<br />

WXBM11200NU<br />

WXB31200N<br />

WXB31200NU<br />

WXBM31200N<br />

WXBM31200NU<br />

3-26<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 08/31/19<br />

Type WBT Feed Thru Tap Box with Horizontal Bus Breaker<br />

WBT - Feed Thru Tap Box with Breaker<br />

The feed thru tap box with breaker (type WBT) offers<br />

the ability to pull conductors in and out of the enclosure<br />

for rise cable or loop feed applications as well as a main<br />

breaker device utilizing an incoming and out-going thru bus<br />

connections (including incoming lugs). In addition users don’t<br />

have to utilize any additional tap boxes as lugs are already<br />

included in the units. This can save the end-user on the<br />

material cost of the meter bank.<br />

The breaker in the WBT module only protects the floor that it<br />

is on. The vertical feed-thru lugs bypass the breaker entirely;<br />

This is the main distinction between the WBT and the BFT.<br />

Do not get this unit confused with the BFT main feed thru, as<br />

described on pages 3-30 -3-32. The BFT protects the floor it<br />

is on as well as the vertical cable run leaving out of the top of<br />

the unit, whereas the WBT only protects the floor it is on.<br />

The WBT cannot be used as a service entrance point therefor<br />

the neutral and ground are un-bonded. With that in mind, be<br />

sure to have an upstream protective device (BFT, WB, WEB,<br />

switchboard, etc.) ahead of the WBT module.<br />

3 METER<br />

CENTERS<br />

Features include:<br />

n QuickSystem features<br />

n Incoming and Outgoing Power Mod thru bus<br />

n Standard compression lug capability<br />

n 65K AIC standard, 100K AIC available for all models<br />

n Broad ampacity ratings from 200-1200A<br />

n Field installable shunt trip<br />

n DAS blue light models available in 1200 Amps<br />

Feed Thru Tap Box with Breaker Quick Reference<br />

n 200-1200A breaker rating<br />

n 1200-2400A feed-thru rating<br />

n 1200A horizontal bus rating<br />

n UL Standard #67<br />

n UL file #E27100<br />

n AIC rating (65K and 100K)<br />

n Voltage:<br />

– Three Phase 240V AC max<br />

n All swing latches and rivets are stainless steel<br />

n NEMA 3R (outdoor)<br />

n G90 galvanized steel<br />

n ANSI 61 paint<br />

Restrictions for WBT Feed Thru breaker tapbox units:<br />

Type WBT breaker tap boxes cannot be used as service equipment. The feed thru conductors must have upstream<br />

circuit protection. For feed thru conductor ratings up to 2,000 amps, Siemens Sentron or VL circuit breakers can be used.<br />

For feed thru conductor ratings over 2,000 amps but up to 2,400 amps, use Class L fuses. Please note that Siemens type<br />

WL circuit breakers CANNOT be used as the direct upstream main for these WBT feed thru breaker tap boxes.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-27


Power Mod<br />

Revised on 08/31/19<br />

Type WBT Feed Thru Tap Box with Horizontal Bus Breaker<br />

Connects via lugs.<br />

Lug kits not included. Lug kits must<br />

be ordered separately per module.<br />

Refer to pages 3-129– 3-130 for<br />

lug size options.<br />

3<br />

METER<br />

CENTERS<br />

Not for use as service equipment.<br />

Restrictions for WBT Feed Thru breaker tapbox units:<br />

Type WBT breaker tap boxes cannot be used as service equipment. The feed thru conductors must have upstream circuit protection.<br />

For feed thru conductor ratings up to 2,000 amps, Siemens Sentron or VL circuit breakers can be used. For feed thru conductor ratings<br />

over 2,000 amps but up to 2,400 amps, use Class L fuses. Please note that Siemens type WL circuit breakers CANNOT be used as the<br />

direct upstream main for these WBT feed thru breaker tap boxes.<br />

Type WBT Feed Thru Tap Box with Horizontal Bus Breaker<br />

Thermal magnetic circuit breaker modules: 3-phase, 4-wire SN, 240V AC max.<br />

Catalog Number<br />

(65KAIC)<br />

Catalog Number<br />

(100KAIC) b<br />

Catalog Number<br />

(65KAIC)<br />

Blank Endwall<br />

Catalog Number<br />

(100KAIC)<br />

Blank Endwall b<br />

Breaker<br />

Amperage<br />

Rating<br />

Feed<br />

Through<br />

Bus Rating<br />

Breaker<br />

Type<br />

Dimensions (inches) a<br />

Height Width Depth<br />

1200A Feed Through Bus<br />

WBT312X200 WBT312X200U WBT312X200NH WBT312X200UNH 200 1200 JXD6 64.58 27.65 13.24<br />

WBT312X250 WBT312X250U WBT312X250NH WBT312X250UNH 250 1200 JXD6 64.58 27.65 13.24<br />

WBT312X300 WBT312X300U WBT312X300NH WBT312X300UNH 300 1200 JXD6 64.58 27.65 13.24<br />

WBT312X350 WBT312X350U WBT312X350NH WBT312X350UNH 350 1200 JXD6 64.58 27.65 13.24<br />

WBT312X400 WBT312X400U WBT312X400NH WBT312X400UNH 400 1200 JXD6 64.58 27.65 13.24<br />

WBT312X450 WBT312X450U WBT312X450NH WBT312X450UNH 450 1200 LXD6 64.58 27.65 13.24<br />

WBT312X500 WBT312X500U WBT312X500NH WBT312X500UNH 500 1200 LXD6 64.58 27.65 13.24<br />

WBT312X600 WBT312X600U WBT312X600NH WBT312X600UNH 600 1200 LXD6 64.58 27.65 13.24<br />

2400A Feed Through Bus<br />

WBT324X200 WBT324X200U WBT324X200NH WBT324X200UNH 200 2400 JXD6 77.94 35.55 14.95<br />

WBT324X250 WBT324X250U WBT324X250NH WBT324X250UNH 250 2400 JXD6 77.94 35.55 14.95<br />

WBT324X300 WBT324X300U WBT324X300NH WBT324X300UNH 300 2400 JXD6 77.94 35.55 14.95<br />

WBT324X350 WBT324X350U WBT324X350NH WBT324X350UNH 350 2400 JXD6 77.94 35.55 14.95<br />

WBT324X400 WBT324X400U WBT324X400NH WBT324X400UNH 400 2400 JXD6 77.94 35.55 14.95<br />

WBT324X450 WBT324X450U WBT324X450NH WBT324X450UNH 450 2400 LXD6 77.94 35.55 14.95<br />

WBT324X500 WBT324X500U WBT324X500NH WBT324X500UNH 500 2400 LXD6 77.94 35.55 14.95<br />

WBT324X600 WBT324X600U WBT324X600NH WBT324X600UNH 600 2400 LXD6 77.94 35.55 14.95<br />

WBT324X700 WBT324X700U WBT324X700NH WBT324X700UNH 700 2400 MXD6 77.94 35.55 14.95<br />

WBT324X800 WBT324X800U WBT324X800NH WBT324X800UNH 800 2400 MXD6 77.94 35.55 14.95<br />

WBT324X900 WBT324X900U WBT324X900NH WBT324X900UNH 900 2400 NXD6 77.94 35.55 14.95<br />

WBT324X1000 WBT324X1000U WBT324X1000NH WBT324X1000UNH 1000 2400 NXD6 77.94 35.55 14.95<br />

WBT324X1200 WBT324X1200U WBT324X1200NH WBT324X1200UNH 1200 2400 NXD6 77.94 35.55 14.95<br />

DAS electronic circuit breaker modules with blue light maintanance mode: 3-phase, 4 wire SN, 240V AC max<br />

Catalog Number<br />

(65KAIC)<br />

Catalog Number<br />

(100KAIC) b<br />

Catalog Number<br />

(65KAIC)<br />

Blank Endwall<br />

Catalog Number<br />

(100KAIC)<br />

Blank Endwall b<br />

Breaker<br />

Amperage<br />

Rating<br />

Feed<br />

Through<br />

Bus Rating<br />

Breaker<br />

Type<br />

Dimensions (inches) a<br />

Height Width Depth<br />

2400A Feed Through Bus<br />

WBTM324X12 WBTM324X12U WBTM324X12NH WBTM324X12UNH 1200 2400 SND6 79.75 35.55 16.96<br />

a Dimensions subject to changes.<br />

b Non Standard item – extended lead time applies.<br />

3-28<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 08/31/19<br />

Type WBT Feed Thru Tap Box with Horizontal Bus Breaker<br />

Feed Thru Tap Box with Horizontal Bus Breaker: 1200A<br />

WBT312X200NH<br />

WBT312X200UNH<br />

WBT312X250NH<br />

WBT312X250UNH<br />

WBT312X300NH<br />

WBT312X300UNH<br />

WBT312X350NH<br />

WBT312X350UNH<br />

Top Endwall View<br />

No Hub Version<br />

WBT312X400NH<br />

WBT312X400UNH<br />

WBT312X450NH<br />

WBT312X450UNH<br />

WBT312X500NH<br />

WBT312X500UNH<br />

WBT312X600NH<br />

WBT312X600UNH<br />

Top Endwall View<br />

Hub Opening Version<br />

WBT312X200<br />

WBT312X200U<br />

WBT312X250<br />

WBT312X250U<br />

WBT312X300<br />

WBT312X300U<br />

WBT312X350<br />

WBT312X350U<br />

WBT312X400<br />

WBT312X400U<br />

WBT312X450<br />

WBT312X450U<br />

WBT312X500<br />

WBT312X500U<br />

WBT312X600<br />

WBT312X600U<br />

3 METER<br />

CENTERS<br />

Feed Thru Tap Box with Horizontal Bus Breaker: 2400A<br />

Top Endwall View No Hub Version<br />

WBT324X200NH<br />

WBT324X200UNH<br />

WBT324X250NH<br />

WBT324X250UNH<br />

WBT324X300NH<br />

WBT324X300UNH<br />

WBT324X350NH<br />

WBT324X350UNH<br />

WBT324X400NH<br />

WBT324X400UNH<br />

WBT324X450NH<br />

WBT324X450UNH<br />

WBT324X500NH<br />

WBT324X500UNH<br />

WBT324X600NH<br />

WBT324X600UNH<br />

WBT324X700NH<br />

WBT324X700UNH<br />

WBT324X800NH<br />

WBT324X800UNH<br />

WBT324X900NH<br />

WBT324X900UNH<br />

WBT324X1000NH<br />

WBT324X1000UNH<br />

WBT324X1200NH<br />

WBT324X1200UNH<br />

WBTM324X12NH<br />

WBTM324X12UNH<br />

Top Endwall View Hub Opening Version<br />

WBT324X200<br />

WBT324X200U<br />

WBT324X250<br />

WBT324X250U<br />

WBT324X300<br />

WBT324X300U<br />

WBT324X350<br />

WBT324X350U<br />

WBT324X400<br />

WBT324X400U<br />

WBT324X450<br />

WBT324X450U<br />

WBT324X500<br />

WBT324X500U<br />

WBT324X600<br />

WBT324X600U<br />

WBT324X700<br />

WBT324X700U<br />

WBT324X800<br />

WBT324X800U<br />

WBT324X900<br />

WBT324X900U<br />

WBT324X1000<br />

WBT324X1000U<br />

WBT324X1200<br />

WBT324X1200U<br />

WBTM324X12<br />

WBTM324X12U<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-29


Power Mod<br />

Revised on 06/30/19<br />

Type BFT Main Feed Thru<br />

BFT - Main Feed Thru Modules<br />

The BFT is a main breaker module for the Power Mod group<br />

metering line up that has the ability to isolate power to<br />

side-mounted modules just like any other Power Mod main<br />

breaker module, but also contains feed-through lugs that can<br />

be used to supply and isolate power vertically to downstream<br />

group metering line ups. This is a revolutionary product in<br />

cabled riser applications.<br />

3<br />

METER<br />

CENTERS<br />

The breaker in the BFT protects both the horizontal bus as<br />

well as the vertical cables leaving the top of the module. The<br />

BFT can be used as the service entrance point and therefore<br />

the neutral and ground is bonded in the unit. The neutral and<br />

ground can be un-bonded for non-service entrance applications.<br />

Features include:<br />

n QuickSystem features<br />

n Suitable for use as service entrance equipment<br />

n Breaker protects power outgoing, vertically and horizontally<br />

n 1200 amp meets EUSERC requirements<br />

n Incoming and outgoing Power Mod thru bus<br />

n Standard compression lug capability<br />

n 65K AIC standard, 100K AIC available for all models<br />

n Main breaker with broad ampacity ratings from 1200A<br />

to 2000A<br />

n Field installable shunt trip<br />

n DAS Blue light models available in 1400-1600 amps"<br />

n For 1200A DAS you must use a 1400A DAS module and<br />

have the trip setting dialed down to 1200A.<br />

Main Feed Thru Quick Reference<br />

n 1200-2000A module rating (breaker)<br />

n 1200-2000A feed-thru rating<br />

n 1200A horizontal bus rating<br />

n UL Standard #67<br />

n UL file #E27100<br />

n AIC rating (65K and 100K)<br />

n Voltage: 240V AC max<br />

n Available in single-phase and three-phase<br />

n All swing latches and rivets are stainless steel<br />

n NEMA 1 (indoor)<br />

n G90 galvanized steel<br />

n ANSI 61 paint<br />

n All modules are bottom-feed only<br />

n All modules have no hubs<br />

n EUSERC drawing #347<br />

3-30<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 08/31/20<br />

Type BFT Main Feed Thru<br />

Connects via lugs.<br />

Lug kits not included. Lug kits must be ordered<br />

separately per module.<br />

Refer to pages 3-129– 3-130 for lug size<br />

options.<br />

Suitable for use as service equipment.<br />

Bonding means may be removed for nonservice<br />

entrance equipment applications.<br />

Type BFT Main Feed Thru<br />

Thermal magnetic circuit breaker modules: 1-phase, 3-wire SN, 120/240V AC<br />

Catalog Number<br />

(65KAIC)<br />

Catalog Number<br />

(100KAIC) b<br />

Breaker<br />

Amperage<br />

Rating<br />

Breaker Type<br />

(65K AIC)<br />

Dimensions (inches) a<br />

Breaker Type<br />

(100K AIC) b Height Width Depth<br />

BFT11200B BFT11200BU 1200 PXD6 HPXD6 89.78 35.53 15.05<br />

BFT11400B BFT11400BU 1400 PXD6 HPXD6 89.78 35.53 15.05<br />

BFT11600B BFT11600BU 1600 PXD6 HPXD6 89.78 35.53 15.05<br />

BFT11800B BFT11800BU 1800 RXD6 HRXD6 89.78 35.53 15.05<br />

BFT12000B BFT12000BU 2000 RXD6 HRXD6 89.78 35.53 15.05<br />

3 METER<br />

CENTERS<br />

Thermal magnetic circuit breaker modules: 3-phase, 4-wire SN, 240V AC max<br />

Catalog Number<br />

(65KAIC)<br />

Catalog Number<br />

(100KAIC) b<br />

Breaker<br />

Amperage<br />

Rating<br />

Breaker Type<br />

(65K AIC)<br />

Dimensions (inches) a<br />

Breaker Type<br />

(100K AIC) b Height Width Depth<br />

BFT31200B BFT31200BU 1200 PXD6 HPXD6 89.78 35.53 15.05<br />

BFT31400B BFT31400BU 1400 PXD6 HPXD6 89.78 35.53 15.05<br />

BFT31600B BFT31600BU 1600 PXD6 HPXD6 89.78 35.53 15.05<br />

BFT31800B BFT31800BU 1800 RXD6 HRXD6 89.78 35.53 15.05<br />

BFT32000B BFT32000BU 2000 RXD6 HRXD6 89.78 35.53 15.05<br />

DAS electronic circuit breaker modules with blue light maintanance mode: 1-phase, 3 wire SN, 120/240V AC<br />

Catalog Number<br />

(65KAIC)<br />

Catalog Number<br />

(100KAIC) b<br />

Breaker<br />

Amperage<br />

Rating<br />

Dimensions (inches) a<br />

Breaker Type Breaker Type<br />

(65K AIC) c (100K AIC) bc Height Width Depth<br />

BFTM11400B BFTM11400BU 1400 SPD6 SHPD6 89.78 35.53 15.05<br />

BFTM11600B BFTM11600BU 1600 SPD6 SHPD6 89.78 35.53 15.05<br />

BFTM11800B BFTM11800BU 1800 RXD6 HRXD6 89.78 35.53 15.05<br />

BFTM12000B BFTM12000BU 2000 RXD6 HRXD6 89.78 35.53 15.05<br />

DAS electronic circuit breaker modules with blue light maintanance mode: 3-phase, 4 wire SN, 240V AC max<br />

Catalog Number<br />

(65KAIC)<br />

Catalog Number<br />

(100KAIC) b<br />

Breaker<br />

Amperage<br />

Rating<br />

Dimensions (inches) a<br />

Breaker Type Breaker Type<br />

(65K AIC) c (100K AIC) bc Height Width Depth<br />

BFTM31400B BFTM31400BU 1400 SPD6 SHPD6 89.78 35.53 15.05<br />

BFTM31600B BFTM31600BU 1600 SPD6 SHPD6 89.78 35.53 15.05<br />

BFTM31800B BFTM31800BU 1800 RXD6 HRXD6 89.78 35.53 15.05<br />

BFTM32000B BFTM32000BU 2000 RXD6 HRXD6 89.78 35.53 15.05<br />

a Dimensions subject to changes.<br />

b Non Standard item – extended lead time applies.<br />

c 1800 amp and 2000 amp units utilize CT's and Relays to operated in Maintenance Mode.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-31


Power Mod<br />

Revised on 12/13/17<br />

Type BFT Main Feed Thru<br />

Type BFT Main Feed Thru: Single-phase<br />

METER<br />

CENTERS<br />

3<br />

Type BFT Main Feed Thru: Three-phase<br />

3-32<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 10/31/19<br />

Type WS Standard Switch Mains<br />

Standard Switch Mains<br />

Standard switch modules (type WS) are designed for<br />

flexibility, space savings, and durability.<br />

Features include:<br />

n QuickSystem features<br />

n Standard compression lug capability<br />

n Invertibility: 400-800 Amp devices can be rotated to<br />

accommodate the desired incoming feed direction<br />

n 750 kcmil AL wire options for most models<br />

n 100K AIC standard for all models<br />

n Class T fuse provisions<br />

n Front mounted handle – removes the need for<br />

spacers on the side<br />

n Broad ampacity ratings up to 1200 Amps<br />

n Handle is lockable in the ON or OFF positions<br />

3 METER<br />

CENTERS<br />

Standard Switch Mains quick reference<br />

n 200-1200A module rating<br />

n 1200A horizontal bus rating<br />

n UL Standard # UL98<br />

n UL file #E25506<br />

n AIC rating (100k AIC)<br />

n Voltage:<br />

– Single phase 120/240V AC max<br />

– Three phase 240V AC max<br />

n All swing latches and rivets are stainless steel<br />

n NEMA 3R rated<br />

n G90 galvanized steel<br />

n ANSI 61 paint<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-33


Power Mod<br />

Revised on 10/31/19<br />

Type WS Standard Switch Mains<br />

Suitable for use as service equipment.<br />

Bonding means may be removed for nonservice<br />

entrance equipment applications.<br />

Lugs not included on<br />

most models.<br />

NEMA 2-stud lugs<br />

must be installed by<br />

user or utility.<br />

Refer to pages 3-129–<br />

3-130 for lug size<br />

options.<br />

METER<br />

CENTERS<br />

3<br />

Fusible switch service entrance modules: 1-phase, 3-wire SN, 120/240V AC f<br />

Catalog number<br />

(100k AIC)<br />

Catalog number<br />

(100k AIC)<br />

Blank Endwall<br />

Rating<br />

amps<br />

Service<br />

feed<br />

Fuse Dimensions (inches) a Line side<br />

type f Height Width Depth connections<br />

Knockout<br />

Diagrams<br />

WMP02U b WMP02UNH 200 OH/UG T 33.00 12.00 13.00 (1) #6 - 250 KCMIL S-0<br />

WS1400CU c WS1400CUNH 400 OH/UG d T 50.13 15.19 16.31 1 set of 2 studs<br />

WS1600CU c WS1600CUNH 600 OH/UG d T 50.13 15.19 16.31<br />

(lugs not included)<br />

S-1<br />

WS1800CU c WS1800CUNH 800 OH/UG d T 50.13 15.19 16.31<br />

2 sets of 2 studs<br />

(lugs not included)<br />

S-2<br />

WS11200BU eg — 1200 UG T 50.06 20.22 16.06 (4) 250- 500 kcmil S-3<br />

Fusible switch service entrance modules: 3-phase, 4-wire WN, 240V AC Max. f<br />

Catalog number<br />

(100k AIC)<br />

Catalog number<br />

(100k AIC)<br />

Blank Endwall<br />

Rating<br />

amps<br />

Service<br />

feed<br />

a Fuse<br />

Dimensions (inches)<br />

Line side<br />

type f Height Width Depth connections<br />

Knockout<br />

Diagrams<br />

WMP024U b WMP024UNH 200 OH/UG T 33.00 12.00 13.00 (1) #6 - 250 KCMIL S-0<br />

WS3400CU c WS3400CUNH 400 OH/UG d T 50.13 15.19 16.31 1 set of 2 studs<br />

WS3600CU c WS3600CUNH 600 OH/UG d T 50.13 15.19 16.31<br />

(lugs not included)<br />

S-1<br />

WS3800CU c WS3800CUNH 800 OH/UG d T 50.13 15.19 16.31<br />

2 sets of 2 studs<br />

(lugs not included)<br />

S-2<br />

WS31200BU eg — 1200 UG T 50.06 20.22 16.06 (4) 250-500 kcmil S-3<br />

a Dimensions shown are representative of outside<br />

box dimensions and do not include allowances for<br />

mounting bumps, endwalls, covers, hubs, or hardware<br />

protrusions. Dimensions are subject to change.<br />

b Additional lead time required. Contact sales office for<br />

details. Fusible pull-out switch.<br />

c Lugs not included. Refer to page 3-129–3-130 for lug size<br />

options. NEMA 2-stud compression lugs must be<br />

installed by user or utility.<br />

d Module is invertible – rotate device to point hub openings<br />

to appropriate feed direction.<br />

e 500 kcmil max wire range size.<br />

f Fuses not included.<br />

g Device uses a molded case switch (looks like a breaker).<br />

Class T fuses must be installed in conjunction with the<br />

molded case switch for proper operation.<br />

Depending on installation details and adjacent product,<br />

a WSP spacer module may be required to provide<br />

enough clearance for hinges/latches. Contact your local<br />

sales person for support<br />

3-34<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Type WS Standard Switch Mains: Knockout Diagrams<br />

3 METER<br />

CENTERS<br />

S-1<br />

WS1400CU<br />

WS1600CU<br />

WS3400CU<br />

WS3600CU<br />

S-0<br />

WMP02U<br />

WMP024U<br />

20- 7/32<br />

16 -1/16<br />

18- 5/16<br />

50- 1/16<br />

23- 1/2 TO<br />

CROSS BUS<br />

CENTER<br />

15- 3/4 TO<br />

NEUTRAL<br />

LUGS<br />

16- 15/16<br />

TO PHASE<br />

LUGS<br />

15- 7/32 TO<br />

GROUND<br />

LUG<br />

35- 1/8 TO<br />

BOTTOM OF<br />

QUICK ROLL<br />

BRACKET<br />

17- 23/32<br />

REMOVABLE<br />

BOTTOM ENDWALL<br />

12 -23/32<br />

S-2<br />

S-3<br />

WS1800CU<br />

WS3800CU<br />

WS11200BU<br />

WS31200BU<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-35


Power Mod<br />

Revised on 10/31/19<br />

Type WES Switch-Pullbox Combinations<br />

Switch-Pullbox Combinations<br />

EUSERC - compliant switch-pullbox combination<br />

modules (type WES) offer EUSERC compatibility, a<br />

wider range of lug options, and extra space for pulling<br />

in conductors.<br />

3<br />

METER<br />

CENTERS<br />

Features include:<br />

n QuickSystem features<br />

n NEMA 2-stud lug mounting pattern<br />

n Broad ampacity ratings up to 1200 Amps<br />

n 750kcmil AL wire options<br />

n 100K AIC standard for all models<br />

n Removable blank bottom endwall<br />

n Front mounted handle - removes the need for<br />

spacers on the side<br />

n Class T fuse provisions<br />

n Large removable ground wire trough with generous<br />

space for grounding conductors<br />

n Extra ground lugs in each device<br />

n Handle is lockable in the ON or OFF positions<br />

Switch-Pullbox Combinations quick reference<br />

n 400-1200A module rating<br />

n 1200A horizontal bus rating<br />

n UL standard # UL98<br />

n UL file # E25506<br />

n AIC Rating (100k AIC)<br />

n Voltage:<br />

– Single phase 120/240V AC max<br />

– Three phase 240V AC max<br />

n All swing latches and rivets are stainless steel.<br />

n NEMA 3R rated<br />

n G90 galvanized steel<br />

n ANSI 61 paint<br />

n EUSERC drawing number 347<br />

3-36<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 10/31/19<br />

Type WES Switch-Pullbox Combinations<br />

Suitable for use as service equipment.<br />

Bonding means may be removed for nonservice<br />

entrance equipment applications.<br />

Lugs not included.<br />

NEMA 2-stud lugs<br />

must be installed by<br />

user or utility.<br />

Refer to pages 3-129–<br />

3-130 for lug size<br />

options.<br />

Combination fusible switch and pullbox modules: 1-phase, 3-wire SN, 120/240V AC<br />

Meets EUSERC requirements c<br />

Catalog number<br />

(100k AIC)<br />

Rating<br />

Amps<br />

Service<br />

feed<br />

Dimensions (inches) a Line sideb<br />

Fuse<br />

type b connections<br />

Height Width Depth (lugs not included)<br />

Knockout<br />

Diagram<br />

3 METER<br />

CENTERS<br />

WES1400BU 400 UG T 54.06 29.19 15.94<br />

1 set of 2 studs<br />

ES-1<br />

WES1600BU 600 UG T 54.06 29.19 15.94 2 sets of 2 studs<br />

WES1800BU 800 UG T 54.06 29.19 15.94<br />

ES-2<br />

WES11200BU d 1200 UG T 68.97 34.25 13.47<br />

3 sets of 2 studs<br />

ES-3<br />

Combination fusible switch and pullbox modules: 3-phase, 4-wire SN, 240V AC max.<br />

Meets EUSERC requirements c<br />

Catalog number<br />

(100k AIC)<br />

Rating<br />

Amps<br />

Service<br />

feed<br />

Fuse<br />

type<br />

Dimensions (inches) a<br />

Height Width Depth<br />

Line side b<br />

connections<br />

(lugs not included)<br />

Knockout<br />

Diagram<br />

WES3400BU 400 UG T 54.06 29.19 15.94<br />

1 set of 2 studs<br />

ES-1<br />

WES3600BU 600 UG T 54.06 29.19 15.94 2 sets of 2 studs<br />

WES3800BU 800 UG T 54.06 29.19 15.94<br />

ES-2<br />

WES31200BU d 1200 UG T 68.97 34.25 13.47<br />

3 sets of 2 studs<br />

ES-3<br />

a Dimensions shown are representative of outside<br />

box dimensions and do not include allowances for<br />

mounting bumps, endwalls, covers, hubs, or hardware<br />

protrusions. Dimensions are subject to change.<br />

b Lugs not included. Refer to page 3-129–3-130 for lug size<br />

options. NEMA 2-stud compression lugs must be<br />

installed by user or utility.<br />

c Fuses not included.<br />

d Device uses a molded case switch (looks like a breaker).<br />

Class T fuses must be installed in conjunction with the<br />

molded case switch for proper operation.<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-37


Power Mod<br />

Type WES Switch-Pullbox Combinations: Knockout Diagrams<br />

METER<br />

CENTERS<br />

3<br />

ES-1<br />

ES-2<br />

WES1400BU<br />

WES3400BU<br />

WES1600BU<br />

WES1800BU<br />

WES3600BU<br />

WES3800BU<br />

34 -1/4<br />

13 -15/32<br />

26 -9/16<br />

ES-3<br />

1- 3/4" NEMA<br />

STUD SPACING<br />

68 -31/32<br />

44- 7/8 TO<br />

WES11200BU<br />

WES31200BU<br />

}<br />

BOTTOM OF<br />

QUICK ROLL<br />

BRACKET<br />

33 -1/4 TO<br />

26 -13/16 TO<br />

PHASE AND<br />

CROSS BUS<br />

CENTER<br />

NEUTRAL STUDS<br />

29 -1/8<br />

3 -7/8<br />

(3) 3/4" KOs<br />

8- 5/8<br />

1 -1/8<br />

REMOVABLE BOTTOM<br />

ENDWALL OPENING<br />

3-38<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 10/31/19<br />

Type WXS Switch Units<br />

Cross Bus Switch modules<br />

Cross Bus switch modules (type WXS) offer two<br />

distinct functions: first they can be used to connect<br />

Siemens Sentron Busway to a Power Mod line-up.<br />

Second they can be utilized to offer lower service<br />

disconnect ampacities or unique configurations where<br />

an incoming tap box is preferred.<br />

Features include:<br />

n QuickSystem features<br />

n Incoming and outgoing bus connections<br />

(right to left or left to right)<br />

n Standardized connection points to Siemens<br />

Sentron Busway<br />

n 100K AIC standard for all models<br />

n Externally accessible switch handle with<br />

padlock capability<br />

n Class T fuse provisions<br />

n Invertibility: Devices must be installed with line and<br />

load side in correct order<br />

n Handle is lockable in the ON or OFF positions<br />

3 METER<br />

CENTERS<br />

Circuit Breaker-Pullbox Combinations Quick Reference<br />

n 400-800A module rating<br />

n 1200A horizontal bus rating<br />

n UL Standard # UL98<br />

n UL file # E25506<br />

n AIC rating (100k)<br />

n Voltage:<br />

– Single phase 120/240V AC max<br />

–Three phase 240V AC max<br />

n All swing latches and rivets are stainless steel<br />

n NEMA 3R rated<br />

n G90 galvanized steel<br />

n ANSI 61 paint<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-39


Power Mod<br />

Revised on 06/30/19<br />

Type WXS Switch Units<br />

Not suitable for use as service equipment.<br />

Connects via<br />

horizontal bussing<br />

only - NO LUGS<br />

METER<br />

CENTERS<br />

3<br />

1-phase, 3-wire SN, 120/240V AC b<br />

Catalog number<br />

(100k AIC)<br />

Ampere<br />

rating<br />

Service<br />

Feed<br />

Fuse<br />

Type<br />

Dimensions a<br />

Height Width Depth<br />

WXS1400NU 400 Horizontal Bus T 35.62 18.16 16.31<br />

WXS1600NU 600 Horizontal Bus T 35.62 18.16 16.31<br />

Knockout<br />

diagram<br />

WXS1800NU 800 Horizontal Bus T 35.62 18.16 16.31 WXS<br />

WXS<br />

3-phase, 4-wire SN, 240V AC max b<br />

Catalog Number<br />

(100k AIC) c Ampere<br />

rating<br />

Service<br />

Feed<br />

Fuse<br />

Type<br />

Dimensions a<br />

Height Width Depth<br />

WXS3400NU 400 Horizontal Bus T 35.62 18.16 16.31<br />

WXS3600NU 600 Horizontal Bus T 35.62 18.16 16.31<br />

Knockout<br />

diagram<br />

WXS3800NU 800 Horizontal Bus T 35.62 18.16 16.31 WXS<br />

WXS<br />

a Dimensions shown are representative of outside<br />

box dimensions and do not include allowances for<br />

mounting bumps, endwalls, covers, hubs, or hardware<br />

protrusions. Dimensions are subject to change.<br />

b Connects via horizontal bussing only – NO LUGS.<br />

3-40<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 04/25/17<br />

Type WXS Switch Units: Knockout Diagrams<br />

3 METER<br />

CENTERS<br />

WXS1400NU<br />

WXS1600NU<br />

WXS1800NU<br />

WXS<br />

WXS3400NU<br />

WXS3600NU<br />

WXS3800NU<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-41


Power Mod<br />

Revised on 10/31/19<br />

Type WTB Standard Tap boxes<br />

Standard Tap boxes<br />

Standard tap box modules (type WTB) are designed<br />

for versatility, space savings, and flexibility.<br />

3<br />

METER<br />

CENTERS<br />

Features include:<br />

n QuickSystem features<br />

n Standard compression lug capability<br />

n Invertibility: some devices can be rotated to<br />

accommodate the desired incoming feed direction<br />

(1600 Amps and lower)<br />

n 750 kcmil AL wire options for most models<br />

n 100K AIC standard for all models<br />

n Broad ampacity ratings from 400 to 2400 Amps<br />

n Line and load capability- service entrance and sub<br />

feed rated<br />

Standard Tapbox quick reference<br />

n 400-2400A module rating<br />

n 1200A horizontal bus rating<br />

n UL Standard # UL67<br />

n UL file # E27100<br />

n AIC rating (100K AIC)<br />

n Voltage<br />

– Single phase 120/240V AC max<br />

– Three phase 240V AC max<br />

n All swing latches and rivets are stainless steel.<br />

n NEMA 3R rated<br />

n G90 galvanized steel<br />

n ANSI 61 paint<br />

Restrictions for 1600-2400amp type WTB Power Mod Tap Boxes:<br />

When the 1600, 2000, or 2400amp tap boxes are used as service entrance equipment (fed directly from utility<br />

transformer) or when the supply originates from a Class L fuse or Siemens WL circuit breaker there are restrictions on the<br />

use of an additional down-stream horizontal cross-bus connected WTBN, WTB, WET, or WT type Power Mod tap boxes.<br />

When another tap box is connected to the same meter-bank, a type “WXB” module must be used as protection for the<br />

down- stream tap box (placed between the incoming WTB tap box and the downstream outgoing tap box). This restriction<br />

does NOT apply if the tap box is fed from a Siemens Sentron or VL series molded case circuit breaker. Note that the<br />

maximum amperage for a Siemens Sentron circuit breaker is 2,000amps.<br />

3-42<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 10/31/19<br />

Type WTB Standard Tap boxes<br />

Restrictions for 1600-2400amp type WTB Power Mod Tap Boxes:<br />

Lugs not included.<br />

When the 1600, 2000, or 2400amp tap boxes are used as service entrance equipment (fed<br />

directly from utility transformer) or when the supply originates from a Class L fuse or Siemens<br />

WL circuit breaker there are restrictions on the use of an additional down-stream horizontal crossbus<br />

connected WTBN, WTB, WET, or WT type Power Mod tap boxes. When another tap box is<br />

connected to the same meter-bank, a type “WXB” module must be used as protection for the<br />

down- stream tap box (placed between the incoming WTB tap box and the downstream outgoing<br />

tap box). This restriction does NOT apply if the tap box is fed from a Siemens Sentron or VL series<br />

molded case circuit breaker. Note that the maximum amperage for a Siemens Sentron circuit<br />

breaker is 2,000amps.<br />

NEMA 2-stud lugs<br />

must be installed<br />

by user or utility.<br />

Refer to pages<br />

3-129 – 3-130 for<br />

lug size options.<br />

Suitable for use as service equipment. Bonding means may<br />

be removed for non-service entrance equipment applications.<br />

Tap box modules: 1-phase, 3-wire WN, 120/240V AC e<br />

Catalog number<br />

(100k AIC)<br />

Catalog number<br />

(100k AIC)<br />

Blank Endwall<br />

Ampere<br />

rating c<br />

Service<br />

feed<br />

Dimensions (inches) a<br />

Height Width Depth<br />

Line side<br />

connections b<br />

(lugs not included)<br />

KO<br />

Diagram<br />

3 METER<br />

CENTERS<br />

WTB1400CU WTB1400CUNH 400 OH/UG d 40.13 12.22 13.19 1 set of 2 studs T-1<br />

WTB1800CU<br />

WTB11200CU<br />

WTB1800CUNH<br />

WTB11200CUNH<br />

800 OH/UG d 40.13 12.22 13.19<br />

T-2<br />

2 sets of 2 studs<br />

1200 OH/UG d 47.13 15.61 13.31 T-3<br />

WTB11600CU f WTB11600CUNH f 1600 OH/UG d 50.25 25.09 13.81<br />

3 sets of 2 studs<br />

T-4<br />

WTB12000TU f WTB12000TUNH f OH<br />

2000<br />

WTB12000BU f — UG<br />

WTB12400TU f WTB12400TUNH OH<br />

2400<br />

WTB12400BU f — UG<br />

67.94 35.00 14.78 3 sets of 2 studs<br />

67.94 35.00 14.78<br />

3 sets of 2 studs<br />

Optional 4 sets<br />

of 2 studs gh<br />

T-6<br />

Tap box modules: 3-phase, 4-wire SN, 240V AC Max. e<br />

Catalog number<br />

(100k AIC)<br />

Catalog number<br />

(100k AIC)<br />

Blank Endwall<br />

Ampere<br />

rating c<br />

Service<br />

feed<br />

Dimensions (inches) a<br />

Height Width Depth<br />

Line side<br />

connections b<br />

(lugs not included)<br />

KO<br />

Diagram<br />

WTB3400CU WTB3400CUNH 400 OH/UG d 40.13 12.22 13.19 1 set of 2 studs T-1<br />

WTB3800CU WTB3800CUNH 800 OH/UG d 40.13 12.22 13.19<br />

T-2<br />

2 sets of 2 studs<br />

WTB31200CU WTB31200CUNH 1200 OH/UG d 60.31 15.61 17.75 T-3<br />

WTB31600CU f WTB31600CUNH f 1600 OH/UG d 50.25 25.09 13.81<br />

3 sets of 2 studs<br />

T-5<br />

WTB32000TU f WTB32000TUNH f OH<br />

2000<br />

WTB32000BU f — UG<br />

WTB32400TU f WTB32400TUNH OH<br />

2400<br />

WTB32400BU f — UG<br />

67.94 35.00 14.78 3 sets of 2 studs<br />

67.94 35.00 14.78<br />

3 sets of 2 studs<br />

Optional 4 sets<br />

of 2 studs gh<br />

T-6<br />

a Dimensions shown are representative of outside box<br />

dimensions and do not include allowances for mounting<br />

bumps, endwalls, covers, hubs, or hardware protrusions.<br />

Dimensions are subject to change.<br />

b Lugs not included. Refer to page 3-129 – 3-130 for lug<br />

size options. 750 conductor size available NEMA 2-stud<br />

compression lugs must be installed by user or utility.<br />

c 1200 amp maximum feed per side, any unit over<br />

1200A must be used as a center fed main.<br />

d Module is invertible- rotate device to point hub openings<br />

to appropriate feed direction.<br />

e QuickConnect not included. If used for load side<br />

application an additional coupler must be ordered.<br />

f Please see restriction note above.<br />

g Please see lug kit number LK18500N2C on pages<br />

3-129 – 3-130. For use with 500kcmil ONLY.<br />

h Fits 2400amp models ONLY.<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-43


Power Mod<br />

Revised on 12/13/17<br />

Type WTB Standard Tap boxes: Knockout Diagrams<br />

METER<br />

CENTERS<br />

3<br />

T-1<br />

WTB1400CU<br />

WTB3400CU<br />

T-2<br />

WTB1800CU<br />

WTB3800CU<br />

T-3<br />

WTB11200CU<br />

WTB31200CU<br />

3-44<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 12/13/17<br />

Type WTB Standard Tap boxes: Knockout Diagrams<br />

3 METER<br />

CENTERS<br />

T-4<br />

WTB11600CU<br />

T-5<br />

WTB31600CU<br />

TOP VIEW FOR BOTTOM FED<br />

VIEW FOR TOP FED<br />

T-6<br />

WTB12000TU<br />

WTB12000BU<br />

WTB12400TU<br />

WTB12400BU<br />

WTB32000TU<br />

WTB32000BU<br />

WTB32400TU<br />

WTB32400BU<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-45


Power Mod<br />

Revised on 06/30/19<br />

Type WET Tap box - Pullbox Combinations<br />

Tap box – Pullbox Combinations<br />

EUSERC – compliant Tap box – Pullbox Combination<br />

modules (type WET) offer EUSERC compatibility, a<br />

wider range of lug options, and extra space for pulling<br />

in conductors.<br />

3<br />

METER<br />

CENTERS<br />

Features include:<br />

n QuickSystem features<br />

n Standard compression lug capability<br />

n 750 kcmil AL wire options for most models<br />

n 100K AIC standard for all models<br />

n Broad ampacity ratings from 400 to 1200 Amps<br />

n Removable bottom endwall<br />

Tap box – Pullbox Combination quick reference<br />

n 400-1200A module rating<br />

n 1200A horizontal bus rating<br />

n UL Standard #’s UL67<br />

n UL file # E27100<br />

n AIC Rating (100k)<br />

n Voltage<br />

– Single phase 120/240V AC max<br />

– Three phase 240V AC max<br />

n All swing latches and rivets are stainless steel.<br />

n NEMA 3R rated<br />

n G90 galvanized steel<br />

n ANSI 61 paint<br />

n EUSERC drawing numbers 343 and 347<br />

3-46<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 10/31/19<br />

Type WET Tap box - Pullbox Combinations<br />

Suitable for use as service equipment.<br />

Bonding means may be removed for nonservice<br />

entrance equipment applications.<br />

Lugs not included.<br />

NEMA 2-stud lugs<br />

must be installed by<br />

user or utility.<br />

Refer to pages 3-129–<br />

3-130 for lug size<br />

options.<br />

EUSERC tap box modules: 1-phase, 3-wire SN, incoming, 120/240V AC<br />

Meets EUSERC requirements<br />

3 METER<br />

CENTERS<br />

Catalog number<br />

(100k AIC)<br />

Ampere<br />

rating<br />

feed Height Width Depth (lugs not included)<br />

Service<br />

Dimensions (inches) a Line side<br />

connections b<br />

WET1400BU 400 UG 46.19 17.63 8.56<br />

1 set of 2 studs<br />

Knockout Diagram<br />

ET-1<br />

WET1800BU 800 UG 50.19 27.13 11.38<br />

2 sets of 2 studs<br />

ET-2<br />

WET11200BU 1200 UG 50.19 35.19 11.38<br />

3 sets of 2 studs<br />

ET-3<br />

EUSERC tap box modules: 3-phase, 4-wire SN, incoming, 240V AC max.<br />

Meets EUSERC requirements<br />

Catalog number<br />

(100k AIC)<br />

Ampere<br />

rating<br />

Service<br />

feed<br />

Dimensions (inches) a<br />

Height Width Depth<br />

WET3400BU 400 UG 46.19 17.63 8.56<br />

Line side<br />

connections b<br />

(lugs not included)<br />

1 set of 2 studs<br />

Knockout Diagram<br />

ET-1<br />

WET3800BU 800 UG 50.19 27.13 11.38<br />

2 sets of 2 studs<br />

ET-2<br />

WET31200BU 1200 UG 50.19 35.19 11.38<br />

3 sets of 2 studs<br />

ET-3<br />

a Dimensions shown are representative of outside<br />

box dimensions and do not include allowances for<br />

mounting bumps, endwalls, covers, hubs, or hardware<br />

protrusions. Dimensions are subject to change.<br />

b Lugs not included. Refer to page 3-129–3-130 for lug<br />

size options. NEMA 2-stud compression lugs must be<br />

installed by user or utility.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-47


Power Mod<br />

Type WET Tap box - Pullbox Combinations: Knockout Diagrams<br />

ET-1<br />

WET1400BU<br />

WET3400BU<br />

ET-2<br />

WET1800BU<br />

WET3800BU<br />

METER<br />

CENTERS<br />

3<br />

ET-3<br />

WET11200BU<br />

WET31200BU<br />

3-48<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 10/31/19<br />

Type WT Feed Thru Tap box<br />

Feed Thru Tap box<br />

Family (type WT), the Feed Thru Tap box features<br />

cable in cable out lugs. Valuable for use in mid rise<br />

and high rise projects.<br />

Features include:<br />

n QuickSystem features<br />

n Standard compression lug capability<br />

n 250kcmil AI wire options<br />

n 100k AIC standard<br />

n Removable bottom endwell<br />

n Broad ampacity ratings from 400 to 2400 Amps<br />

3 METER<br />

CENTERS<br />

Feed Thru Tap box quick reference<br />

■ 400-2400A module rating<br />

■ 400-2400A feed-thru rating<br />

■ 1200A horizontal bus rating<br />

■ UL standard 67<br />

■ UL file no. E27100<br />

■ AIC rating (100k AIC)<br />

■ Voltage:<br />

– Single phase 120/240V AC max.<br />

– Three phase, 240V AC max<br />

■ All swing latches and rivets are stainless steel.<br />

■ NEMA 3R rated<br />

■ G90 galvanized steel<br />

■ ANSI 61 paint<br />

Restrictions for Power Mod 1600-2400amp type WT Feed Thru Tap Boxes:<br />

Type WT feed thru tap boxes cannot be used as service equipment. The feed thru conductors must have upstream<br />

circuit protection. When fed by a Class L fuse, there are restrictions on the use of additional down-stream horizontal<br />

cross-bus connected WTBN, WET, or WT type Power Mod tap boxes. When another tap box is connected to the<br />

same meter-bank, a type WXB module must be used as protection for the downstream tap box (placed between the<br />

incoming WT tap box and the downstream outgoing tap box). This restriction does NOT apply if the tap box is fed<br />

from a Siemens Sentron or VL series molded case circuit breaker. Note that the maximum amperage for a Siemens<br />

Sentron circuit breaker is 2,000A. Please note that Siemens type WL circuit breakers CANNOT be used to feed<br />

WT Power Mod tap boxes.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-49


Power Mod<br />

Revised on 10/31/19<br />

Type WT Feed Thru Tap box<br />

3<br />

Restrictions for 1600-2400amp type WT Power Mod Pull-Thru Tap Boxes:<br />

Type WT feed thru tap boxes cannot be used as service equipment. The feed thru<br />

conductors must have upstream circuit protection. When fed by a Class L fuse, there are<br />

restrictions on the use of additional down-stream horizontal cross-bus connected WTBN,<br />

WET, or WT type Power Mod tap boxes. When another tap box is connected to the same<br />

meter-bank, a type WXB module must be used as protection for the downstream tap<br />

box (placed between the incoming WT tap box and the downstream outgoing tap box).<br />

This restriction does NOT apply if the tap box is fed from a Siemens Sentron or VL series<br />

molded case circuit breaker. Note that the maximum amperage for a Siemens Sentron<br />

circuit breaker is 2,000A. Please note that Siemens type WL circuit breakers CANNOT be<br />

used to feed WT Power Mod tap boxes.<br />

Lug kits not<br />

included.<br />

(2) Lug kits<br />

must be ordered<br />

separately per<br />

module.<br />

Refer to pages<br />

3-129–3-130 for<br />

lug size options.<br />

METER<br />

CENTERS<br />

Not suitable for use as service equipment.<br />

Feed Thru Tap box modules: 1-phase, 120/240V AC<br />

Catalog<br />

number (100k AIC)<br />

Catalog<br />

number (100k AIC)<br />

Blank Endwall<br />

Ampere<br />

rating<br />

Service<br />

feed<br />

Dimensions (inches) KO<br />

Height Width Depth Line side conections Diagram<br />

WT1400PU WT1400PUNH 400<br />

59.25 17.25 8.13 1 set of 2 studs<br />

WT1800PU WT1800PUNH 800 62.25 26.75 11.13 2 sets of 2 studs<br />

WT11200PU WT11200PUNH 1200 68.34 35.19 11.41<br />

WT11600PU WT11600PUNH 1600 OH/UG<br />

67.94 35 14.78<br />

WT12000PU WT12000PUNH 2000<br />

WT12400PU WT12400PUNH 2400 67.94 35 14.78<br />

3 sets of 2 studs<br />

3 sets of 2 studs<br />

Optional 4 sets<br />

of 2 studs <br />

WP-1<br />

WP-2<br />

Feed Thru Tap box modules: 3-phase, 240V AC<br />

Catalog<br />

number (100k AIC)<br />

Catalog<br />

number (100k AIC)<br />

Blank Endwall<br />

Ampere<br />

rating<br />

Service feed<br />

Dimensions (inches) KO<br />

Height Width Depth Line side conections Diagram<br />

WT3400PU WT3400PUNH 400<br />

59.25 17.25 8.13 1 set of 2 studs<br />

WT3800PU WT3800PUNH 800 62.25 26.75 11.13 2 sets of 2 studs<br />

WT31200PU WT31200PUNH 1200 68.34 35.19 11.41<br />

WT31600PU WT31600PUNH 1600 OH/UG<br />

67.94 35 14.78<br />

WT32000PU WT32000PUNH 2000<br />

WT32400PU WT32400PUNH 2400 67.94 35 14.78<br />

3 sets of 2 studs<br />

3 sets of 2 studs<br />

Optional 4 sets<br />

of 2 studs <br />

WP-1<br />

WP-2<br />

Dimensions shown are representative of outside box<br />

dimensions and do not include allowances for mounting<br />

bumps, endwalls, covers, hubs, or hardware<br />

protrusions. Dimensions are subject to change.<br />

Lugs not included. Refer to page 3-129–3-130 for lug<br />

size options. (2) Lug kits must be ordered separately<br />

per module. Refer to page 3-129 – 3-130 for lug<br />

size options.<br />

1200 amp maximum feed per side-must be used as a<br />

center fed main.<br />

Please see restriction note above.<br />

Optional four sets of two studs obtained by installing<br />

bus extension which is provided in all applicable lug<br />

kits.<br />

3-50<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Type WT Feed Thru Tap box: Knockout Diagrams<br />

3 METER<br />

CENTERS<br />

WP-1<br />

WT11200PU<br />

WT31200PU<br />

WT11600PU<br />

WP-2<br />

WT31600PU<br />

WT12000PU<br />

WT12400PU<br />

WT32000PU<br />

WT32400PU<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-51


Power Mod<br />

Revised on 06/30/19<br />

Type WMM Residential Meter Stacks<br />

Residential Meter Stacks<br />

Power Mod’s core offering of Residential Meter<br />

Stacks, type WMM, offers the widest product offering<br />

and flexibility in the industry. Each meter stack<br />

houses the QuickSystem features to maximize<br />

productivity and minimize labor costs. To aid in<br />

productivity and labor cost reductions our 225 Amp<br />

meter stacks feature a new breaker - the “QS”. The<br />

QS breaker adds to the Siemens exclusive feature set<br />

on our new 225 Amp Residential Meter Stacks.<br />

3<br />

METER<br />

CENTERS<br />

Benefits of the “QS” include:<br />

J An exclusive 6 high 225 Amp meter stack at the<br />

same height as our 125 Amp meter stack - 225 to<br />

125 conversion: No conversion kit needed.<br />

J Single right hand bend wiring - saves time and wire<br />

J 100K AIC offered from 100 up to 225 Amps<br />

Siemens Residential Meter Stacks are packed with<br />

features inside and out: our exclusive knock out plate<br />

offers flexibility when pulling wires to the stack, new<br />

breaker supports keep breakers level and straight,<br />

moveable neutrals and grounds to save wire, and all<br />

of the QuickSystem features all designed with the<br />

contractor in mind.<br />

Residential Meter Stacks quick reference<br />

n 2-6 gang<br />

n 125/225 Amp per position<br />

n 1200 Amp horizontal bus rating<br />

n UL standard 67<br />

n UL file no. E27100<br />

n AIC rating (100k)<br />

n Voltage:<br />

– Single phase 120/240V AC max.<br />

– Three phase in single phase out<br />

● 120/208V AC max.<br />

● 240/120V AC max.<br />

n All swing latches and rivets are stainless steel.<br />

n Outdoor= NEMA 3R rated<br />

n Indoor= NEMA 1R rated<br />

n G90 galvanized steel<br />

n ANSI 61 paint<br />

n Ring type units comply with EUSERC drawing<br />

number 353<br />

3-52<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 06/30/19<br />

Type WMM Residential Meter Stacks – 1 phase 4J<br />

n 2-6 gang<br />

n 125/225 Amp<br />

per position<br />

n 1200 Amp horizontal<br />

bus rating<br />

Residential 4-jaw ring type meter stacks: 1-phase, 3-wire SN, incoming and outgoing c <br />

Outdoor<br />

catalog number<br />

Indoor<br />

catalog number<br />

Meter positions<br />

per stack<br />

Max. tenant breaker (Amps): 125<br />

WMM21125 MM21125 2 Position<br />

Breaker provision<br />

Maximum<br />

Dimensions (inches) a Knockout<br />

AIC e Height Width Depth diagram<br />

100k 34.31 13.09 8.09 KA-12<br />

WMM31125 MM31125 3 Position QP, QPH,<br />

100k 43.31 13.09 8.09 KA-13<br />

WMM41125 MM41125 4 Position<br />

HQP, HQPH,<br />

MP-T, MP-HT,<br />

100k 52.31 13.09 8.09 KA-14<br />

WMM51125 MM51125 5 Position MP-MT<br />

100k 61.31 13.09 8.09 KA-15<br />

WMM61125 MM61125 6 Position 100k 70.31 13.09 8.09 KA-16<br />

Max. tenant breaker (Amps): 225 <br />

WMM21225 MM21225 2 Position<br />

100k 34.31 16.22 8.09 KA-22<br />

WMM31225 MM31225 3 Position QS, QSH, QSHH,<br />

HQS, HQSH, QP,<br />

100k 43.31 16.22 8.09 KA-23<br />

WMM41225 MM41225 4 Position QPH, HQP, HQPH, 100k 52.31 16.22 8.09 KA-24<br />

WMM51225 MM51225 5 Position<br />

MP-T, MP-HT,<br />

MP-MT<br />

100k 61.31 16.22 8.09 KA-25<br />

WMM61225 MM61225 6 Position 100k 70.31 16.22 8.09 KA-26<br />

3 METER<br />

CENTERS<br />

Residential 4-jaw ringless type meter stacks: 1-phase, 3-wire SN, incoming and outgoing c <br />

Outdoor<br />

catalog<br />

number<br />

(no bypass)<br />

Outdoor<br />

catalog<br />

number<br />

(horn bypass)<br />

Indoor<br />

catalog<br />

number<br />

(no bypass)<br />

Indoor<br />

catalog<br />

number<br />

(horn bypass)<br />

Meter<br />

positions<br />

per stack<br />

Max. tenant breaker (Amps): 125<br />

WMM21125R WMM21125RB MM21125R MM21125RB 2 Position<br />

Breaker<br />

provision<br />

a Max.<br />

Dimensions (inches)<br />

Knockout<br />

AIC e Height Width Depth diagram<br />

100k 34.31 13.09 8.09 KA-12<br />

WMM31125R<br />

WMM41125R<br />

WMM51125R<br />

WMM31125RB<br />

WMM41125RB<br />

WMM51125RB<br />

MM31125R<br />

MM41125R<br />

MM51125R<br />

MM31125RB<br />

MM41125RB<br />

MM51125RB<br />

3 Position<br />

4 Position<br />

5 Position<br />

QP, QPH,<br />

HQP, HQPH,<br />

MP-T,<br />

MP-HT,<br />

MP-MT<br />

100k<br />

100k<br />

100k<br />

43.31<br />

52.31<br />

61.31<br />

13.09<br />

13.09<br />

13.09<br />

8.09<br />

8.09<br />

8.09<br />

KA-13<br />

KA-14<br />

KA-15<br />

WMM61125R WMM61125RB MM61125R MM61125RB 6 Position 100k 70.31 13.09 8.09 KA-16<br />

Max. tenant breaker (Amps): 225 <br />

WMM21225R WMM21225RB MM21225R MM21225RB 2 Position<br />

100k 34.31 16.22 8.09 KA-22<br />

WMM31225R WMM31225RB MM31225R MM31225RB 3 Position<br />

QS, QSH,<br />

QSHH, HQS, 100k 43.31 16.22 8.09 KA-23<br />

WMM41225R WMM41225RB MM41225R MM41225RB 4 Position<br />

HQSH, QP,<br />

QPH, HQP, 100k 52.31 16.22 8.09 KA-24<br />

WMM51225R WMM51225RB MM51225R MM51225RB 5 Position<br />

HQPH, MP-T,<br />

MP-HT, 100k 61.31 16.22 8.09 KA-25<br />

MP-MT<br />

WMM61225R WMM61225RB MM61225R MM61225RB 6 Position 100k 70.31 16.22 8.09 KA-26<br />

a Dimensions shown are representative of outside<br />

box dimensions and do not include allowances for<br />

mounting bumps, endwalls, covers, hubs, or hardware<br />

protrusions. Dimensions are subject to change.<br />

b 225A available in lower three positions only. 200A<br />

continuous for all other positions.<br />

c NOT for use on 3-phase, 4-wire delta systems.<br />

d Field installable 5th jaw (ECMF5). Fifth jaw can be<br />

isolated if needed (ECMF5i).<br />

e Max AIC determined by maximum AIC of tenant<br />

breakers. Higher ratings may be achieved through<br />

approved series rating combinations.<br />

f Install QP breakers below QS breakers.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-53


Power Mod<br />

Revised on 06/30/19<br />

Type WMM Residential Meter Stacks – 1 phase 5J<br />

n 2-6 gang<br />

n 125/225 Amp<br />

per position<br />

n 1200 Amp<br />

horizontal bus rating<br />

METER<br />

CENTERS<br />

3<br />

Residential 5-jaw ring type meter stacks: 1-phase, 3-wire SN, incoming and outgoing cd<br />

Outdoor<br />

catalog number<br />

Indoor<br />

catalog number<br />

Meter positions<br />

per stack<br />

Max. tenant breaker (Amps): 125<br />

WMM21125J MM21125J 2 Position<br />

Breaker provision<br />

Maximum<br />

Dimensions (inches) a Knockout<br />

AIC e Height Width Depth diagram<br />

100k 34.31 13.09 8.09 KA-12<br />

WMM31125J MM31125J 3 Position QP, QPH,<br />

100k 43.31 13.09 8.09 KA-13<br />

WMM41125J MM41125J 4 Position<br />

HQP, HQPH,<br />

MP-T, MP-HT,<br />

100k 52.31 13.09 8.09 KA-14<br />

WMM51125J MM51125J 5 Position MP-MT<br />

100k 61.31 13.09 8.09 KA-15<br />

WMM61125J MM61125J 6 Position 100k 70.31 13.09 8.09 KA-16<br />

Max. tenant breaker (Amps): 225 <br />

WMM21225J MM21225J 2 Position<br />

100k 34.31 16.22 8.09 KA-22<br />

WMM31225J MM31225J 3 Position QS, QSH, QSHH,<br />

HQS, HQSH, QP,<br />

100k 43.31 16.22 8.09 KA-23<br />

WMM41225J MM41225J 4 Position QPH, HQP, HQPH, 100k 52.31 16.22 8.09 KA-24<br />

WMM51225J MM51225J 5 Position<br />

MP-T, MP-HT,<br />

MP-MT<br />

100k 61.31 16.22 8.09 KA-25<br />

WMM61225J MM61225J 6 Position 100k 70.31 16.22 8.09 KA-26<br />

Residential 5-jaw ringless type meter stacks: 1-phase, 3-wire SN, incoming and outgoing c d<br />

Outdoor<br />

catalog<br />

number<br />

(no bypass)<br />

Outdoor<br />

catalog<br />

number<br />

(horn bypass)<br />

Max. tenant breaker (Amps): 125<br />

Indoor<br />

catalog<br />

number<br />

(no bypass)<br />

Indoor<br />

catalog<br />

number<br />

(horn bypass)<br />

Meter<br />

positions<br />

per stack<br />

WMM21125RJ WMM21125RJB MM21125RJ MM21125RJB 2 Position<br />

Breaker provision<br />

Dimensions (inches) a<br />

Max.<br />

Knockout<br />

AIC e Height Width Depth diagram<br />

100k 34.31 13.09 8.09 KA-12<br />

WMM31125RJ WMM31125RJB MM31125RJ MM31125RJB 3 Position<br />

QP, QPH,<br />

100k 43.31 13.09 8.09 KA-13<br />

WMM41125RJ WMM41125RJB MM41125RJ MM41125RJB 4 Position<br />

HQP, HQPH,<br />

MP-T, MP-HT,<br />

100k 52.31 13.09 8.09 KA-14<br />

WMM51125RJ WMM51125RJB MM51125RJ MM51125RJB 5 Position<br />

MP-MT<br />

100k 61.31 13.09 8.09 KA-15<br />

WMM61125RJ WMM61125RJB MM61125RJ MM61125RJB 6 Position 100k 70.31 13.09 8.09 KA-16<br />

Max. tenant breaker (Amps): 225 <br />

WMM21225RJ WMM21225RJB MM21225RJ MM21225RJB 2 Position<br />

100k 34.31 16.22 8.09 KA-22<br />

WMM31225RJ WMM31225RJB MM31225RJ MM31225RJB 3 Position<br />

QS, QSH,<br />

QSHH, HQS, 100k 43.31 16.22 8.09 KA-23<br />

WMM41225RJ WMM41225RJB MM41225RJ MM41225RJB 4 Position<br />

HQSH, QP,<br />

QPH, HQP, 100k 52.31 16.22 8.09 KA-24<br />

WMM51225RJ WMM51225RJB MM51225RJ MM51225RJB 5 Position<br />

HQPH, MP-T,<br />

MP-HT, 100k 61.31 16.22 8.09 KA-25<br />

MP-MT<br />

WMM61225RJ WMM61225RJB MM61225RJ MM61225RJB 6 Position 100k 70.31 16.22 8.09 KA-26<br />

a Dimensions shown are representative of outside<br />

box dimensions and do not include allowances for<br />

mounting bumps, endwalls, covers, hubs, or hardware<br />

protrusions. Dimensions are subject to change.<br />

b 225A available in lower three positions only. 200A<br />

continuous for all other positions.<br />

c NOT for use on 3-phase, 4-wire delta systems.<br />

d Field installable 5th jaw (ECMF5). Fifth jaw can be<br />

isolated if needed (ECMF5i).<br />

e Max AIC determined by maximum AIC of tenant breakers.<br />

Higher ratings may be achieved through approved<br />

series rating combinations.<br />

f Install QP breakers below QS breakers.<br />

3-54<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 06/30/19<br />

Type WMM Residential Meter Stacks – 3 phase in 1 phase out 5J<br />

n 2-6 gang<br />

n 125/225 Amp<br />

per position<br />

n 1200 Amp<br />

horizontal bus rating<br />

Residential 5-jaw ring type meter stacks: 3-phase, 4-wire SN, incoming and 1-phase, 3 wire SN outgoing cdg<br />

Outdoor<br />

catalog<br />

number<br />

Indoor<br />

catalog<br />

number<br />

Meter<br />

positions<br />

per stack<br />

Max. tenant breaker (Amps): 125<br />

WMM22125J MM22125J 2 Position<br />

Breaker provision<br />

Maximum<br />

Dimensions (inches) a Knockout<br />

AIC e Height Width Depth diagram<br />

100k 34.31 13.09 8.09 KA-12<br />

WMM32125J MM32125J 3 Position<br />

QP, QPH,<br />

100k 43.31 13.09 8.09 KA-13<br />

WMM42125J MM42125J 4 Position HQP, HQPH, MP-T, 100k 52.31 13.09 8.09 KA-14<br />

WMM52125J MM52125J 5 Position<br />

MP-HT, MP-MT<br />

100k 61.31 13.09 8.09 KA-15<br />

WMM62125J MM62125J 6 Position 100k 70.31 13.09 8.09 KA-16<br />

Max. tenant breaker (Amps): 225 <br />

WMM22225J MM22225J 2 Position<br />

100k 34.31 16.22 8.09 KA-22<br />

WMM32225J MM32225J 3 Position QS, QSH, QSHH, 100k 43.31 16.22 8.09 KA-23<br />

WMM42225J MM42225J 4 Position<br />

HQS, HQSH, QP,<br />

QPH, HQP, HQPH,<br />

100k 52.31 16.22 8.09 KA-24<br />

WMM52225J MM52225J 5 Position MP-T, MP-HT, MP-MT 100k 61.31 16.22 8.09 KA-25<br />

WMM62225J MM62225J 6 Position 100k 70.31 16.22 8.09 KA-26<br />

3 METER<br />

CENTERS<br />

Residential 5-jaw ringless type meter stacks: 3-phase, 4-wire SN, incoming and 1-phase, 3 wire SN outgoing cdg<br />

Outdoor<br />

catalog<br />

number<br />

(no bypass)<br />

Outdoor<br />

catalog<br />

number<br />

(horn Bypass)<br />

Max. tenant breaker (Amps): 125<br />

Indoor<br />

catalog<br />

number<br />

(no bypass)<br />

Indoor<br />

catalog<br />

number<br />

(horn bypass)<br />

Meter<br />

positions<br />

per stack<br />

WMM22125RJ WMM22125RJB MM22125RJ MM22125RJB 2 Position<br />

Breaker<br />

provision<br />

Dimensions (inches) a<br />

Max.<br />

Knockout<br />

AIC e Height Width Depth diagram<br />

100k 34.31 13.09 8.09 KA-12<br />

WMM32125RJ WMM32125RJB MM32125RJ MM32125RJB 3 Position<br />

QP, QPH,<br />

100k 43.31 13.09 8.09 KA-13<br />

WMM42125RJ WMM42125RJB MM42125RJ MM42125RJB 4 Position<br />

HQP, HQPH,<br />

MP-T, MP-HT,<br />

100k 52.31 13.09 8.09 KA-14<br />

WMM52125RJ WMM52125RJB MM52125RJ MM52125RJB 5 Position<br />

MP-MT<br />

100k 61.31 13.09 8.09 KA-15<br />

WMM62125RJ WMM62125RJB MM62125RJ MM62125RJB 6 Position 100k 70.31 13.09 8.09 KA-16<br />

Max. tenant breaker (Amps): 225 <br />

WMM22225RJ WMM22225RJB MM22225RJ MM22225RJB 2 Position<br />

100k 34.31 16.22 8.09 KA-22<br />

WMM32225RJ WMM32225RJB MM32225RJ MM32225RJB 3 Position<br />

QS, QSH,<br />

QSHH, HQS, 100k 43.31 16.22 8.09 KA-23<br />

WMM42225RJ WMM42225RJB MM42225RJ MM42225RJB 4 Position<br />

HQSH, QP,<br />

QPH, HQP, 100k 52.31 16.22 8.09 KA-24<br />

WMM52225RJ WMM52225RJB MM52225RJ MM52225RJB 5 Position<br />

HQPH, MP-T,<br />

MP-HT, 100k 61.31 16.22 8.09 KA-25<br />

MP-MT<br />

WMM62225RJ WMM62225RJB MM62225RJ MM62225RJB 6 Position 100k 70.31 16.22 8.09 KA-26<br />

a Dimensions shown are representative of outside<br />

box dimensions and do not include allowances for<br />

mounting bumps, endwalls, covers, hubs, or hardware<br />

protrusions. Dimensions are subject to change.<br />

b 225A available in lower three positions only. 200A<br />

continuous for all other positions.<br />

c Approved for use on 3-phase, 4-wire delta systems.<br />

Must field phase away from B phase (A and C phase<br />

only).<br />

d 5th jaw can be isolated if needed (ECMF5i).<br />

e Max AIC determined by maximum AIC of tenant breakers.<br />

Higher ratings may be achieved through approved<br />

series rating combinations.<br />

f Install QP breakers below QS breakers.<br />

g Stacks come factory phased as AB, BC, AC... top to<br />

bottom<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-55


4<br />

2-9/32<br />

13-3/32<br />

(6) KOs 1, 1-1/4, 1-1/2, 2"<br />

Power Mod Mod Residential Meter Stacks<br />

125A knockout diagrams<br />

Type WMM Residential Meter Stacks: Knockout Diagrams<br />

8-3/32<br />

Revised on 12/13/17<br />

TO<br />

BUS<br />

R<br />

2-13/16<br />

6<br />

2<br />

YP.<br />

32<br />

2-13/32<br />

3<br />

2-7/16<br />

METER<br />

CENTERS<br />

1-5/8 TYP.<br />

12-31/32<br />

27" TO<br />

BOTTOM OF<br />

QUICK ROLL<br />

BRACKET<br />

9"<br />

TYP.<br />

9"<br />

TYP.<br />

43-5/16<br />

36" TO<br />

BOTTOM OF<br />

QUICK ROLL<br />

BRACKET<br />

52-5/16<br />

36" TO<br />

36" TO<br />

BOTTOM OF<br />

BOTTOM OF<br />

QUICK ROLL 34-5/16<br />

43-5/16 QUICK ROLL<br />

BRACKET<br />

BRACKET<br />

52-5/16<br />

36" TO<br />

BOTTOM OF<br />

QUICK ROLL<br />

24-3/8 TO BRACKET<br />

CROSS BUS<br />

CENTER<br />

12-5/32<br />

24-3/8 TO<br />

12-5/32<br />

CROSS BUS<br />

CENTER<br />

2-13/16<br />

12-5/32<br />

12-5/32 2-13/32<br />

24-3/8 TO 12-5/32 12-5/32<br />

2-13/16<br />

2-13/16<br />

CROSS BUS<br />

2-13/16<br />

2-13/32<br />

CENTER<br />

(6) KOs 1, 1-1/4, 1-1/2, 2"<br />

(6) KOs 1, 1-1/4, 1-1/2, 2"<br />

REMOVABLE PLATE<br />

2-13/32 2-7/16<br />

REMOVABLE PLATE<br />

2-13/32<br />

12-5/32<br />

(6) KOs 1, 1-1/4, 1-1/2, 2"<br />

1-5/8 TYP.<br />

2-13/16<br />

(6) KOs 1, 1-1/4, 1-1/2, 2" 2-7/16<br />

REMOVABLE PLATE<br />

24-3/8 TO<br />

(6) KOs 1, 1-1/4, 1-1/2, 2"<br />

(6) KOs 1, 1-1/4, 1-1/2, 2"<br />

12-31/32 REMOVABLE PLATE<br />

2-7/16<br />

12-31/32<br />

REMOVABLE 2-13/32PLATE<br />

2-7/16 CROSS BUS<br />

REMOVABLE PLATE<br />

1-5/8 TYP.<br />

CENTER<br />

1-5/8 TYP.<br />

1-5/8 TYP.<br />

12-31/32<br />

12-31/32<br />

(6) KOs 1, 1-1/4, 1-1/2, 2"<br />

12-31/32<br />

2-7/16<br />

REMOVABLE PLATE<br />

2-13/16<br />

(6) KOs 1, 1-1/4, 1-1/2, 2"<br />

34-5/16<br />

15-3/8 TO<br />

CROSS BUS<br />

CENTER<br />

WMM21125XX<br />

WMM22125XXX<br />

13-3/32<br />

KA-12<br />

3-1/16 13-3/32 3-1/2 TYP.<br />

MM21125XX<br />

MM22125XXX<br />

9"<br />

TYP.<br />

9"<br />

TYP.<br />

1-5/8 TYP.<br />

WMM31125XX<br />

WMM32125XXX<br />

9"<br />

TYP.<br />

12-31/32<br />

KA-13<br />

9"<br />

TYP.<br />

MM31125XX<br />

MM32125XXX<br />

43-5/16<br />

24-3/8 TO<br />

CROSS BUS<br />

CENTER<br />

36" TO<br />

BOTTOM OF<br />

QUICK ROLL<br />

BRACKET<br />

2-13/32<br />

2-7/16<br />

1-5/8 TYP.<br />

WMM41125XX<br />

WMM42125XXX<br />

9"<br />

TYP.<br />

12-31/32<br />

KA-14<br />

9"<br />

TYP.<br />

12-5/32<br />

MM41125XX<br />

MM42125XXX<br />

(6) KOs 1, 1-1/4, 1-1/2, 2"<br />

REMOVABLE PLATE<br />

36" TO<br />

BOTTOM OF<br />

QUICK ROLL<br />

BRACKET<br />

52-5/16<br />

24-3/8 TO<br />

CROSS BUS<br />

CENTER<br />

2-13/16<br />

2-13/<br />

2-7/1<br />

1-5/8 T<br />

1-15/16<br />

3-1/4<br />

8-3/32<br />

125 Amp Typical Top View for NEMA 1<br />

13-3/32<br />

8-3/32<br />

61-5/16<br />

8-3/32<br />

125 Amp Typical Top View NEMA 3R<br />

36" TO<br />

BOTTOM OF<br />

QUICK ROLL<br />

BRACKET<br />

9"<br />

TYP.<br />

36" TO<br />

BOTTOM OF<br />

QUICK ROLL<br />

BRACKET<br />

70-5/16<br />

3-1/4<br />

2-8<br />

2-9/32<br />

125 Amp Typical Bottom View<br />

(6) KOs 1, 1-1/4, 1-1/2, 2"<br />

24-3/8 TO<br />

CROSS BUS<br />

CENTER<br />

2-13/16<br />

2-13/32<br />

2-7/16<br />

1-5/8 TYP.<br />

WMM51125XX<br />

WMM52125XXX<br />

12-31/32<br />

KA-15<br />

KA-15<br />

12-5/32<br />

MM51125XX<br />

MM52125XXX<br />

(6) KOs 1, 1-1/4, 1-1/2, 2"<br />

REMOVABLE PLATE<br />

24-3/8 TO<br />

CROSS BUS<br />

CENTER<br />

2-13/16<br />

2-13/32<br />

2-7/16<br />

1-5/8 TYP.<br />

WMM61125XX<br />

WMM62125XXX<br />

12-31/32<br />

KA-16<br />

9"<br />

TYP.<br />

12-5/32<br />

(6) KOs 1, 1-1/4, 1-1/2, 2"<br />

REMOVABLE PLATE<br />

MM61125XX<br />

MM62125XXX<br />

3-56<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Power Mod Residential Meter Stacks<br />

Type WMM Residential Meter Stacks: Knockout Diagrams<br />

225A knockout diagrams<br />

Revised on 12/13/17<br />

L<br />

27" TO<br />

BOTTOM OF<br />

QUICK ROLL<br />

BRACKET<br />

34-5/16<br />

36" TO<br />

BOTTOM OF<br />

43-5/16 QUICK ROLL<br />

52-5/16<br />

36" TO<br />

BRACKET34-5/16<br />

36" TO<br />

BOTTOM OF<br />

BOTTOM OF<br />

QUICK ROLL<br />

36" TO<br />

43-5/16 QUICK ROLL<br />

52-5/16<br />

BRACKET<br />

BOTTOM OF<br />

QUICK ROLL<br />

BRACKET<br />

43-5/16<br />

BRACKET<br />

9"<br />

TYP.<br />

9"<br />

9"<br />

TYP.<br />

TYP.<br />

9"<br />

9"<br />

36" TO<br />

9"<br />

-3/8 TO<br />

15-3/8 TO TYP.<br />

24-3/8 TO<br />

TYP.<br />

BOTTOM OF<br />

TYP.<br />

SS BUS<br />

CROSS BUS<br />

CROSS BUS<br />

9"<br />

QUICK ROLL<br />

ENTER<br />

CENTER<br />

CENTER<br />

24-3/8 TO<br />

TYP.<br />

24-3/8 TO<br />

BRACKET<br />

CROSS 12-5/32 BUS<br />

CROSS BUS<br />

2-13/16<br />

12-5/32 CENTER<br />

24-3/8 TO<br />

12-5/32<br />

CROSS BUS<br />

CENTER<br />

2-13/16<br />

CENTER<br />

12-5/32 2-13/32<br />

12-5/32 12-5/32<br />

2-13/16<br />

2-13/32<br />

2-13/32<br />

3/16<br />

2-13/16<br />

12-5/32 2-13/16<br />

2-13/32<br />

2-7/16 (6) KOs 1, 1-1/4, 1-1/2, 2"<br />

(6) KOs 1, 1-1/4, 1-1/2, 2-13/32 2"<br />

REMOVABLE PLATE<br />

2-13/16<br />

2-13/32<br />

24-3/8 TO<br />

(6) KOs 1, 1-1/4, 1-1/2, 2"<br />

2-7/16<br />

2-7/16<br />

2-13/32<br />

CROSS BUS<br />

REMOVABLE PLATE<br />

REMOVABLE PLATE<br />

1-5/8 TYP.<br />

CENTER<br />

1-5/8 TYP.<br />

1-5/8 TYP.<br />

(6) KOs 1, 1-1/4, 1-1/2, 2"<br />

(6) KOs 1, 1-1/4, 1-1/2, 2"<br />

(6) KOs 1, 1-1/4, 1-1/2, 2"<br />

2-7/16<br />

16-3/32<br />

2-7/16<br />

2-7/16<br />

REMOVABLE PLATE<br />

REMOVABLE PLATE<br />

REMOVABLE PLATE<br />

16-3/32<br />

16-3/32<br />

(6) KOs 1, 1-1/4, 1-1/2, 2"<br />

1-5/8 TYP.<br />

1-5/8 TYP.<br />

2-7/16<br />

REMOVABLE PLATE 1-5/8 TYP.<br />

16-7/32<br />

2-13/16<br />

16-3/32<br />

KA-22<br />

16-3/32 1-5/8 TYP.<br />

16-3/32<br />

2-13/32<br />

WMM21225XX MM21225XX<br />

16-3/32<br />

WMM22225XXX MM22225XXX<br />

2-7/16<br />

8-3/32<br />

KA-23<br />

1-5/8 TYP.<br />

WMM31225XX MM31225XX<br />

16-3/32<br />

WMM32225XXX MM32225XXX<br />

WMM41225XX<br />

WMM42225XXX<br />

KA-24<br />

9"<br />

TYP.<br />

12-5/32<br />

MM41225XX<br />

MM42225XXX<br />

36" TO<br />

BOTTOM OF<br />

QUICK ROLL<br />

BRACKET<br />

52-5/16<br />

(6) KOs 1, 1-1/4, 1-1/2, 2"<br />

REMOVABLE PLATE<br />

24-3/8 TO<br />

CROSS BUS<br />

CENTER<br />

3 METER<br />

CENTERS<br />

2-13/16<br />

2-13/32<br />

2-7/16<br />

1-5/8 TYP.<br />

4" TYP.<br />

2" TYP.<br />

2-3/32<br />

16-7/32<br />

2-3/16<br />

3-1/4<br />

8-3/32<br />

225 Amp Typical Top View for NEMA 1<br />

61-5/16<br />

16-7/32<br />

36" TO<br />

BOTTOM OF<br />

QUICK ROLL<br />

BRACKET<br />

70-5/16<br />

8-3/32<br />

9"<br />

TYP.<br />

36" TO<br />

BOTTOM OF<br />

QUICK ROLL<br />

BRACKET<br />

225 Amp Typical Top View for NEMA 3R<br />

4" TYP.<br />

2" TYP.<br />

2-3/16<br />

3-1/4<br />

2-9/32<br />

(6) KOs 1-1/2, 2, 2-1/2"<br />

225 Amp Typical Bottom View<br />

24-3/8 TO<br />

CROSS BUS<br />

CENTER<br />

2-13/16<br />

2-13/32<br />

2-7/16<br />

1-5/8 TYP.<br />

WMM51225XX<br />

WMM52225XXX<br />

16-3/32<br />

KA-25<br />

12-5/32<br />

MM51225XX<br />

MM52225XXX<br />

(6) KOs 1, 1-1/4, 1-1/2, 2"<br />

REMOVABLE PLATE<br />

24-3/8 TO<br />

CROSS BUS<br />

CENTER<br />

2-13/16<br />

2-13/32<br />

2-7/16<br />

1-5/8 TYP.<br />

WMM61225XX<br />

WMM62225XXX<br />

16-3/32<br />

KA-26<br />

9"<br />

TYP.<br />

12-5/32<br />

(6) KOs 1, 1-1/4, 1-1/2, 2"<br />

REMOVABLE PLATE<br />

MM61225XX<br />

MM62225XXX<br />

2-9<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-57


Power Mod<br />

Revised on 06/30/19<br />

Type WML Lever Bypass Meter Stacks<br />

Lever Bypass Meter Stacks<br />

Lever Bypass meter stacks (type WML) are designed<br />

to meet the requirements of those utilities specifying<br />

lever bypass meter sockets for residential and<br />

commercial applications.<br />

3<br />

METER<br />

CENTERS<br />

Features include:<br />

n QuickSystem features a<br />

n High-quality, time-proven Talon HQ sockets<br />

n A line of 3-phase 100 Amp meter stacks to minimize<br />

tenant main cost<br />

n Removable back knockout plate to facilitate wiring<br />

n 225 Amp capability in single and three phase designs<br />

n Up to 4 positions with 225 Amp tenant mains, up to<br />

2 positions with 400 Amp tenant mains<br />

n All lever bypass stacks are ringless.<br />

Lever Bypass quick reference<br />

n 125A 2-6 position<br />

n 100A/225A 1-4 position<br />

n 400A 1-2 position<br />

n 1200A horizontal bus rating<br />

n UL Standard # UL67<br />

n UL file # E27100<br />

n AIC rating (25K, 35K, 65k and 100K)<br />

n Voltage<br />

– Single phase 120/240V AC max<br />

– Three in single phase out 208Y/120V AC<br />

– Three Phase 240V AC max<br />

n All swing latches and rivets are stainless steel.<br />

n Indoor = NEMA 1 rated<br />

n Outdoor = NEMA 3R rated<br />

n G90 galvanized steel<br />

n ANSI 61 paint<br />

a QuickPhase is not applicable with non-field phaseable stacks (WML, 225A-400A,<br />

3-phase-in/3-phase-out).<br />

3-58<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 06/30/19<br />

Type WML Lever Bypass Meter Stacks<br />

n 125A 2-6 position<br />

n 1200A horizontal<br />

bus rating<br />

Commercial Ringless Type Meter Stacks: Lever Bypass<br />

1-Phase, 3-Wire SN, Incoming and Outgoing, Lever Bypass, 5-Jaw Sockets b<br />

3 METER<br />

CENTERS<br />

Outdoor<br />

Catalog Number<br />

Indoor<br />

Catalog Number<br />

Meter<br />

Positions<br />

Per Stack<br />

Max. tenant breaker (Amps): 125<br />

WML21125RJ ML21125RJ 2<br />

Breaker Provisions<br />

Maximum<br />

Dimensions (inches) a Stack Phasing<br />

AIC c Height Width Depth Phases/Sockets<br />

100k 36.18 14.48 11.51 —<br />

WML31125RJ ML31125RJ 3 100k 46.18 14.48 11.51 —<br />

WML41125RJ ML41125RJ 4<br />

QP, QPH, HQP, HQPH,<br />

MP-T, MP-HT, MP-MT<br />

100k 56.18 14.48 11.51 —<br />

WML51125RJ ML51125RJ 5 100k 66.18 14.48 11.51 —<br />

WML61125RJ ML61125RJ 6 100k 76.18 14.48 11.51 —<br />

3-Phase, 4-Wire SN, Incoming and 1-Phase, 3-Wire SN Outgoing, Lever Bypass, 5-Jaw Sockets b<br />

Outdoor<br />

Catalog Number<br />

Indoor<br />

Catalog Number<br />

Meter<br />

Positions<br />

Per Stack<br />

Max. tenant breaker (Amps): 125<br />

WML22125RJ ML22125RJ 2<br />

Breaker Provisions<br />

Maximum<br />

Dimensions (inches) a Stack Phasing<br />

AIC c Height Width Depth Phases/Sockets<br />

100k 36.18 14.48 11.51 —<br />

WML32125RJ ML32125RJ 3<br />

QP, QPH, HQP, HQPH,<br />

100k 46.18 14.48 11.51 —<br />

WML42125RJ ML42125RJ 4 MP-T, MP-HT, MP-MT<br />

100k 56.18 14.48 11.51 —<br />

WML52125RJ ML52125RJ 5 100k 66.18 14.48 11.51 —<br />

WML62125RJ ML62125RJ 6 100k 76.18 14.48 11.51 —<br />

a Dimensions shown are representative of outside<br />

box dimensions and do not include allowances for<br />

mounting bumps, hubs, or hardware protrusions.<br />

b Not for use on 3-phase, 4-wire delta systems.<br />

Max AIC determined by maximum AIC of tenant<br />

breakers when used in conjuntion with a meter socket.<br />

Higher overall ratings may be achieved through<br />

approved series rating combinations.<br />

d Stacks are field phaseable.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-59


Power Mod<br />

Revised on 06/30/19<br />

Type WML Lever Bypass Meter Stacks<br />

n 225A 1-4 position<br />

n 1200A horizontal<br />

bus rating<br />

METER<br />

CENTERS<br />

3<br />

Commercial Ringless Type Meter Stacks: Lever Bypass<br />

1-Phase, 3-Wire SN, Incoming and Outgoing, Lever Bypass, 5-Jaw Sockets b<br />

Meter<br />

Dimensions (inches) a Outdoor<br />

Indoor<br />

Positions<br />

Maximum<br />

Stack phasing<br />

Catalog Number Catalog Number Per Stack Breaker Provisions<br />

AIC c Height Width Depth phases/sockets<br />

Max. tenant breaker (Amps): 225<br />

WML11225RJ ML11225RJ 1<br />

100k 27.75 19.50 9.00 —<br />

WML21225RJ ML21225RJ 2 QS, QSH, QSHH, HQS, HQSH, 100k 40.75 19.50 9.00 —<br />

QP, QPH, HQP, HQPH,<br />

WML31225RJ ML31225RJ 3 MP-T, MP-HT, MP-MT<br />

100k 49.75 19.50 9.00 —<br />

WML41225RJ ML41225RJ 4 100k 62.75 19.50 9.00 —<br />

3-Phase, 4-Wire SN, Incoming and 1-Phase, 3-Wire SN Outgoing, Lever Bypass, 5-Jaw Sockets b<br />

Outdoor<br />

Catalog Number<br />

Indoor<br />

Catalog Number<br />

Max. tenant breaker (Amps): 225<br />

WML12225RJ ML12225RJ 1<br />

Meter<br />

Positions<br />

Per Stack<br />

Breaker Provisions<br />

Maximum<br />

Dimensions (inches) a Stack phasing<br />

AIC c Height Width Depth phases/sockets<br />

100k 27.75 19.50 9.00 1-AB<br />

WML22AB225RJ ML22AB225RJ 2 100k 40.75 19.50 9.00 1-AC, 1-BC<br />

WML22BC225RJ ML22BC225RJ 2 100k 40.75 19.50 9.00 1-AC, 1-AB<br />

WML22CA225RJ ML22CA225RJ 2 QS, QSH, QSHH, HQS, HQSH, 100k 40.75 19.50 9.00 1-AB, 1-BC<br />

QP, QPH, HQP, HQPH,<br />

WML32225RJ ML32225RJ 3 MP-T, MP-HT, MP-MT<br />

100k 49.75 19.50 9.00 1-AB, 1-BC, 1-CA<br />

WML42AB225RJ ML42AB225RJ 4 100k 62.75 19.50 9.00 2-AB, 1-BC, 1-CA<br />

WML42BC225RJ ML42BC225RJ 4 100k 62.75 19.50 9.00 1-AB, 2-BC, 1-CA<br />

WML42CA225RJ ML42CA225RJ 4 100k 62.75 19.50 9.00 1-AB, 1-BC, 2-CA<br />

a Dimensions shown are representative of outside<br />

box dimensions and do not include allowances for<br />

mounting bumps, hubs, or hardware protrusions.<br />

b Not for use on 3-phase, 4-wire delta systems.<br />

Max AIC determined by maximum AIC of tenant<br />

breakers when used in conjuntion with a meter socket.<br />

Higher overall ratings may be achieved through<br />

approved series rating combinations.<br />

d Are field phaseable.<br />

Not field phaseable.<br />

3-60<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 06/30/19<br />

Type WML Lever Bypass Meter Stacks<br />

n 100A/125A<br />

1-4 position<br />

n 1200A horizontal<br />

bus rating<br />

Commercial Ringless Type Meter Stacks: Lever Bypass<br />

3-Phase, 4-Wire SN, Incoming And Outgoing, Lever Bypass, 7-Jaw Sockets e<br />

Outdoor<br />

Catalog Number<br />

Indoor<br />

Catalog Number<br />

Max. tenant breaker (Amps) : 100<br />

Meter Positions<br />

Per Stack<br />

Breaker<br />

Provisions<br />

Maximum<br />

AIC c<br />

Dimensions (inches) a<br />

Height Width Depth<br />

WML13100RJ ML13100RJ 1<br />

65k 27.75 23.50 9.00<br />

WML23100RJ ML23100RJ 2<br />

QP, MP-T, QPH,<br />

MP-HT, HQP,<br />

65k 40.75 23.50 9.00<br />

WML33100RJ ML33100RJ 3<br />

MP-MT<br />

65k 49.75 23.50 9.00<br />

WML43100RJ ML43100RJ 4 65k 62.75 23.50 9.00<br />

Max. tenant breaker (Amps) : 225<br />

WML13225RJ ML13225RJ 1<br />

100k 27.75 23.50 9.00<br />

WML23225RJ ML23225RJ 2 QR2, QRH2,<br />

100k 40.75 23.50 9.00<br />

WML33225RJ ML33225RJ 3<br />

MQ, MQH, MQL,<br />

HQR2, HQR2H<br />

100k 49.75 23.50 9.00<br />

WML43225RJ ML43225RJ 4 100k 62.75 23.50 9.00<br />

3 METER<br />

CENTERS<br />

a Dimensions shown are representative of outside<br />

box dimensions and do not include allowances for<br />

mounting bumps, hubs, or hardware protrusions.<br />

b 3-pole breakers only.<br />

c Max AIC determined by maximum AIC of tenant breakers<br />

when used in conjunction with a meter socket.<br />

Higher overall ratings may be achieved through<br />

approved series rating combinations.<br />

d Rated for use with 240/120V Delta systems.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-61


Power Mod<br />

Revised on 10/31/19<br />

Type WML Lever Bypass Meter Stacks<br />

n 400A 1-2 position<br />

n 1200A horizontal<br />

bus rating<br />

n 25-35KAIC<br />

3<br />

METER<br />

CENTERS<br />

Commercial Ringless Type Meter Stacks: Lever Bypass<br />

Outdoor<br />

Catalog Number<br />

Meter<br />

Positions<br />

Per Stack<br />

Breaker Provisions<br />

Maximum<br />

AIC<br />

Dimensions (inches) a<br />

Height Width Depth<br />

1-Phase, 3-Wire SN, Incoming and Outgoing, Lever Bypass, 5-Jaw Sockets b<br />

Max. tenant breaker (Amps): 400<br />

Socket<br />

Phasing<br />

WML11400RJ 1<br />

JXD62B400<br />

25k 44.00 16.31 9.69 — —<br />

WML21400RJ 2<br />

Factory installed<br />

25k 70.38 23.00 9.69 — —<br />

3-Phase, 4-Wire SN, Incoming and 1-Phase, 3-Wire SN Outgoing, Lever Bypass, 5-Jaw Sockets bd<br />

Max. tenant breaker (Amps): 400<br />

WML12400RJ 1<br />

JXD62B400<br />

25k 44.00 16.31 9.69 1-AB —<br />

WML22400RJ 2<br />

Factory installed<br />

25k 70.38 23.00 9.69 1-AB, 1-BC —<br />

3-Phase, 4-Wire SN, Incoming and Outgoing, Lever Bypass, 7-Jaw Sockets b<br />

Max. tenant breaker (Amps) : 400<br />

WML13400RJ 1<br />

JXD63B400<br />

25k 44.00 16.31 9.69 — —<br />

WML23400RJ 2<br />

Factory installed<br />

25k 70.38 23.00 9.69 — —<br />

Commercial Ringless Type Meter Stacks: Lever Bypass<br />

Max. tenant breaker (Amps) : 400<br />

WML11400RJH 1<br />

Stack<br />

Phasing<br />

35k 51.06 16.34 9.75 — 1 Ph in / 1 Ph out<br />

WML12400RJH 1 CJD6-A<br />

35k 51.06 16.34 9.75 — 3 Ph in / 1 Ph out<br />

WML13400RJH 1 35k 51.06 16.34 9.75 — 3 Ph in / 3 Ph out<br />

Alternate Amperage Breakers<br />

For 1 Position Stacks<br />

Add<br />

Suffix<br />

<br />

Suffix<br />

T1<br />

T19<br />

T2<br />

T3<br />

T4<br />

Breaker<br />

Amperage<br />

200A<br />

225A<br />

250A<br />

300A<br />

350A<br />

Alternate Amperage Breakers<br />

For 2 Position Stacks<br />

Add<br />

Suffix<br />

<br />

Breaker<br />

Breaker<br />

Suffix Amperage Suffix Amperage<br />

T5 200A/200A T15 300A/400A<br />

T6 200A/250A T16 350A/350A<br />

T7 200/300A T17 350A/400A<br />

T8 200/350A T18 250A/250A<br />

T9 200/400A T20 200A/225A<br />

T10 250A/300A T21 225A/225A<br />

T11 250A/350A T22 225A/250A<br />

T12 250A/400A T23 225A/300A<br />

T13 300A/300A T24 225A/350A<br />

T14 300A/350A T25 225A/400A<br />

a Dimensions shown are representative of outside<br />

box dimensions and do not include allowances for<br />

mounting bumps, hubs, or hardware protrusions.<br />

b Not for use on 3-phase, 4-wire delta systems.<br />

Alternate amperage breakers are available. Please<br />

see tables on left for suffix that needs to be added.<br />

Additional lead time may apply. Contact sales<br />

office for details.<br />

Not field phaseable.<br />

3-pole breakers only<br />

3-62<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 06/30/19<br />

Type WML Lever Bypass Meter Stacks<br />

Fusible Switch Lever<br />

Bypass Meter Stacks<br />

Fusible Switch Lever Bypass Meter stacks This Commercial<br />

Lever Bypass meter stacks (type WML) feature a 400 Amp -<br />

class T - fusible pull out assembly..<br />

Features include:<br />

n QuickSystem features<br />

n High-quality, time proven Talon HQ sockets<br />

n Removable back knockout plate to facilitate wiring<br />

n Available in single and three phases designs<br />

n Single position with 400amp tenant main<br />

n All lever bypass stacks are ringless.<br />

3 METER<br />

CENTERS<br />

Lever Bypass With Fusible Switch Quick Reference:<br />

■ 400A 1 position<br />

■ 1200A horizontal bus rating<br />

■ UL Standard #UL67<br />

■ UL file #E27100<br />

■ AIC rating 100KAIC<br />

■ Voltage<br />

– Single phase 120/240V AC Max<br />

– Three phase in, single phase out 208Y/120V AC<br />

– Three Phase 240V AC Max<br />

■ All swing latches and rivets are stainless steel<br />

■ Outdoor = NEMA 3R rated<br />

■ Indoor = NEMA 1 rated<br />

■ G90 galvanized steel<br />

■ ANSI 61 paint<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-63


Power Mod<br />

Revised on 06/30/19<br />

Type WML Lever Bypass Meter Stacks<br />

n 400A 1 position<br />

n 1200A horizontal<br />

bus rating<br />

n 400A Class T fuse<br />

(not included)<br />

METER<br />

CENTERS<br />

3<br />

Fusible Switch Lever Bypass Ringless Meter Stacks<br />

Outdoor<br />

Catalog Number<br />

Indoor<br />

Catalog Number<br />

Max. Tenant Fuse (Amps): 400<br />

Single-Phase In/Out<br />

Meter Positions<br />

Per Stack<br />

Breaker<br />

Provisions<br />

Maximum<br />

AIC<br />

Dimensions (inches) a<br />

Height Width Depth<br />

WML11400RJFS ML11400RJFS 1 Class T fuse 100K 38.31 16.34 11.22<br />

Three-Phase In/ Single-Phase Out<br />

WML12400RJFS ML12400RJFS 1 Class T fuse 100K 38.31 16.34 11.22<br />

Three-Phase In/Out<br />

WML13400RJFS ML13400RJFS 1 Class T fuse 100K 38.31 16.34 11.22<br />

a Dimensions shown are representative of the outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions.<br />

3-64<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Meter Stacks: WML Lever Bypass Stacks Knockout Diagrams<br />

Typical top view<br />

for NEMA 1<br />

L-1<br />

WML11225RJ ML11225RJ<br />

WML12225RJ ML12225RJ L-4<br />

WML41225RJ ML41225RJ<br />

3 METER<br />

CENTERS<br />

WML42AB225RJ<br />

WML42BC225RJ<br />

WML42CA225RJ<br />

ML42AB225RJ<br />

ML42BC225RJ<br />

ML42CA225RJ<br />

L-2<br />

WML21225RJ ML21225RJ<br />

WML22AB225RJ ML22AB225RJ<br />

WML22BC225RJ ML22BC225RJ<br />

WML22CA225RJ ML22CA225RJ<br />

WML11400RJ<br />

WML12400RJ<br />

WML13400RJ<br />

L-5<br />

ML11400RJ<br />

ML12400RJ<br />

ML13400RJ<br />

WML31225RJ<br />

WML32225RJ<br />

L-3<br />

ML31225RJ<br />

ML32225RJ<br />

WML21400RJ<br />

WML22400RJ<br />

L-6<br />

ML21400RJ<br />

ML22400RJ<br />

WML23400RJ<br />

ML23400RJ<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-65


Power Mod<br />

Meter Stacks: WML Lever Bypass Stacks Knockout Diagrams<br />

METER<br />

CENTERS<br />

3<br />

L-7<br />

L-8<br />

WML13100RJ<br />

ML13100RJ<br />

WML23100RJ<br />

ML23100RJ<br />

WML33100RJ<br />

L-9<br />

ML33100RJ<br />

WML43100RJ<br />

L-10<br />

ML43100RJ<br />

3-66<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Meter Stacks: WML Lever Bypass Stacks Knockout Diagrams<br />

WML13225RJ<br />

L-11<br />

ML13225RJ<br />

WML23225RJ<br />

L-12<br />

ML23225RJ<br />

Typical top view<br />

for NEMA 1<br />

3 METER<br />

CENTERS<br />

WML33225RJ<br />

L-13<br />

ML33225RJ<br />

WML43225RJ<br />

L-14<br />

ML43225RJ<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-67


Power Mod<br />

Revised on 06/30/19<br />

Type WMLZF and WMLZ Utility Meter Stacks: Knockout Diagrams<br />

3<br />

METER<br />

CENTERS<br />

Fusible Switch Lever<br />

Bypass Meter Stacks<br />

The WMLZ and WMLZF lever bypass meter stacks are<br />

designed to allow the use of class T (400amp max) fuses<br />

ahead of all meter positions where the local serving utility<br />

may require it. WMLZF stacks feature a 400amp fusible<br />

pull out assembly which connects to a secondary 400amp<br />

horizontal bus that can feed downstream meter stacks. The<br />

WMLZ stacks include the secondary 400amp horizontal bus<br />

that can connect from the WMLZF meter stacks. The standard<br />

Power Mod 1200amp horizontal bus “passes thru” to<br />

feed downstream modules - the meter sockets in WMLZ<br />

and WMLZF do NOT connect directly to the 1200amp horizontal<br />

bus - only to the 400amp horizontal bus.<br />

Features include:<br />

n QuickSystem features<br />

n High-quality, time-proven Talon HQ sockets<br />

n 125 Amp capability for 3-phase in/single-phase out<br />

n 3 to 6 positions in both the fused stack and the<br />

expansion stack<br />

n 400 Amp class T fusible-pullout in WMLZF stacks<br />

n Secondary 400 amp horizontal bus to supply power to<br />

down stream sockets<br />

Xcel Residential Lever Bypass Quick Reference:<br />

■ 125A 3 – 6 position<br />

■ 1200A horizontal bus rating<br />

■ 400A secondary horizontal bus rating and<br />

vertical bus rating<br />

■ UL Standard # UL67<br />

■ UL file #E27100<br />

■ AIC rating (100K)<br />

■ Voltage -Three-phase in/ single-phase out<br />

120/240V AC max<br />

■ All swing latches and rivets are stainless steel<br />

■ Outdoor = NEMA 3R rated<br />

■ Indoor = NEMA 1R rated<br />

■ G90 galvanized steel<br />

■ ANSI 61 paint<br />

3-68<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 10/31/19<br />

Type WMLZF and WMLZ Utility Meter Stacks: Knockout Diagrams<br />

n 125A 3 – 6 position<br />

n 1200A horizontal bus<br />

n 400A 2nd<br />

horizontal bus<br />

n 400A vertical bus<br />

Fused Residential Ringless Type Stacks: Lever Bypass<br />

3-Phase, 4-Wire SN, Incoming and 1Phase, 3-Wire SN, Outgoing, Lever Bypass, 5-Jaw Sockets<br />

Max. tenant breaker (Amps): 125<br />

3 METER<br />

CENTERS<br />

Outdoor<br />

Catalog Number<br />

Indoor<br />

Catalog Number<br />

Meter Positions<br />

Per Stack<br />

Breaker<br />

Provisions<br />

Maximum AIC<br />

Dimensions (inches)<br />

Height Width Depth<br />

WMLZF32125RJ MLZF32125RJ 3<br />

100k 54.06 14.61 11.51<br />

WMLZF42125RJ MLZF42125RJ 4 QP, MP-T, QPH, HQP,<br />

HQPH, MP-HT, MP-MT<br />

100k 64.06 14.61 11.51<br />

WMLZF52125RJ MLZF52125RJ 5 100k 74.06 14.61 11.51<br />

WMLZF62125RJ MLZF62125RJ 6 100k 84.06 14.61 11.51<br />

Non-Fused Residential Ringless Type Stacks: Lever Bypass<br />

3-Phase, 4-Wire SN, Incoming and 1Phase, 3-Wire SN, Outgoing, Lever Bypass, 5-Jaw Sockets<br />

Max. tenant breaker (Amps): 125<br />

Outdoor<br />

Catalog Number<br />

Indoor<br />

Catalog Number<br />

Meter Positions<br />

Per Stack<br />

Breaker<br />

Provisions<br />

Maximum<br />

AIC<br />

Dimensions (inches)<br />

Height Width Depth<br />

WMLZ32125RJ MLZ32125RJ 3<br />

100k 54.06 14.61 11.51<br />

WMLZ42125RJ MLZ42125RJ 4 QP, MP-T, QPH, HQP,<br />

HQPH, MP-HT, MP-MT<br />

100k 64.06 14.61 11.51<br />

WMLZ52125RJ MLZ52125RJ 5 100k 74.06 14.61 11.51<br />

WMLZ62125RJ MLZ62125RJ 6 100k 84.06 14.61 11.51<br />

Accessories<br />

Catalog Number Description<br />

ECWMLZFBUS* WMLZ’s horizontal bussing attachment kit (contains 3 bus bars)<br />

ECWMLZEP<br />

End enclosure plate WMLZ’s and WMLZF’s<br />

ECWMLZBP<br />

Bottom enclosure plate WMLZ and WMLZF<br />

ECWML10<br />

Replacement metal meter cover for 125A (W)MLZ(F) stacks<br />

* Every WMLZ comes with a ECWMLZFBUS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-69


Power Mod<br />

Revised on 06/30/19<br />

Applications: WMLZ/ WMLZF – Fusible Residential Lever Bypass Meter Stacks<br />

Flow of Current<br />

3<br />

WMLZ<br />

WMLZ WMLZF<br />

WMLZF WMLZ WSPD<br />

METER<br />

CENTERS<br />

E<br />

E<br />

C<br />

C<br />

E<br />

Main<br />

Horizontal<br />

Bus<br />

A<br />

F<br />

Secondary<br />

Horizontal<br />

Bus<br />

D<br />

D<br />

B<br />

B<br />

D<br />

A Cables land on a tap box and current enters Power Mod line up on the main horizontal Bus.<br />

B Current is directed from the main horizontal bus down onto the WMLZF’s vertical bus and into the<br />

400 amp fuse pull out.<br />

C The current then goes up on the WMLZF’s vertical bus to feed the sockets.<br />

D WMLZ’s must be fed by a secondary horizontal bus from the WMLZF’s<br />

*Additional connections are required between the WMLZ and WMLZF.<br />

E The current then flows up from the secondary horizontal bus and on to the vertical bus to<br />

feed the sockets in the WMLZ’s.<br />

*More than one WMLZ can be fed from 1 WMLZF.<br />

F The main horizontal bus is used as a pass through on the WMLZ’s for any additional modules attached to the line up.<br />

*Quick Connect MUST be used between every module to maintain the line ups Neutral bonding, even if there are no extra modules<br />

attached at the end of the line up.<br />

3-70<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Type WMLZF and WMLZ Utility Meter Stacks: Knockout Diagrams<br />

3 Meter Stack<br />

WMLZ32125RJ,<br />

MLZ32125RJ<br />

4 Meter Stack<br />

WMLZ42125RJ,<br />

MLZ42125RJ<br />

3 METER<br />

CENTERS<br />

6 Meter Stack<br />

WMLZ62125RJ,<br />

MLZ62125RJ<br />

5 Meter Stack<br />

WMLZ52125RJ,<br />

MLZ52125RJ<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-71


Power Mod<br />

Type WMLZF and WMLZ Utility Meter Stacks: Knockout Diagrams<br />

4 Meter Stack<br />

WMLZF42125RJ,<br />

MLZF42125RJ<br />

3 Meter Stack<br />

WMLZF32125RJ,<br />

MLZF32125RJ<br />

METER<br />

CENTERS<br />

3<br />

6 Meter Stack<br />

WMLZF62125RJ,<br />

MLZF62125RJ<br />

5 Meter Stack<br />

WMLZF52125RJ,<br />

MLZF52125RJ<br />

3-72<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 06/30/19<br />

Type WMT Test Block Bypass Meter Stacks<br />

Test Block Bypass Meter Stacks<br />

Commercial Test Block Bypass Meter Stacks (type<br />

WMT) are designed to meet the requirements of<br />

those utilities specifying test block bypass meter<br />

sockets for commercial applications in areas subscribing<br />

to the EUSERC standards.<br />

Features include:<br />

n QuickSystem features<br />

n High-quality, time-proven Siemens SMM switchboard<br />

meter socket<br />

n Removable back knockout plate to facilitate wiring<br />

n 225 Amp capability in single and three phase<br />

designs<br />

n Up to 3 positions with 225 Amp tenant mains<br />

n Wiring flexibility - tenant mains require only a<br />

single bend<br />

n Three phase input, single phase output modules<br />

n In line wiring: side knockouts allow wiring for<br />

adjacent units to pass through<br />

3 METER<br />

CENTERS<br />

Test Block Bypass Quick Reference<br />

n 225A 1-3 positions<br />

n 1200A horizontal bus rating<br />

n UL Standard #'s UL67<br />

n UL file # E27100<br />

n AIC rating (100K)<br />

n Voltage<br />

– 1 phase 120/240V AC Max<br />

– 3 phase in 1 phase out 120Y/208V AC Max<br />

– 3 phase 240V AC Max<br />

n All swing latches and rivets are stainless steel.<br />

n Outdoor= NEMA 3R rated<br />

n Indoor= NEMA 1R rated<br />

n G90 galvanized Steel<br />

n ANSI 61 Paint<br />

n EUSERC drawing #'s 312 and 353<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-73


Power Mod<br />

Revised on 06/30/19<br />

Type WMT Test Block Bypass Meter Stacks<br />

n 225A 1-3 positions<br />

n 1200A horizontal<br />

bus rating<br />

n AIC Rating (100k)<br />

METER<br />

CENTERS<br />

3<br />

Commercial ring type meter stacks: Test Block Bypass c<br />

Outdoor<br />

Catalog<br />

number<br />

Indoor<br />

Catalog<br />

number<br />

Meter<br />

positions<br />

per stack<br />

Dimensions (inches) a<br />

Breaker provisions<br />

Maximum<br />

AIC Height Width Depth<br />

1-phase, 3-wire SN, incoming and outgoing, test block bypass, 4-jaw sockets b f<br />

Max. tenant breaker (Amps): 225<br />

WMT11225 MT11225 1<br />

QS, QSH, QSHH,<br />

40.50 21.50 9.00 — TB-1<br />

WMT21225 MT21225 2<br />

HQS, HQSH, QP,<br />

QPH, HQP, HQPH,<br />

100k 46.00 21.50 9.00 — TB-2<br />

WMT31225 MT31225 3<br />

MP-T, MP-HT, MP-MT<br />

65.50 21.50 9.00 — TB-3<br />

3-phase, 4-wire SN, incoming and 1-phase, 3-wire SN outgoing, test block bypass, 5-jaw sockets b e<br />

Max. tenant breaker (Amps): 225<br />

Phase<br />

Knockout<br />

diagram<br />

WMT12225J MT12225J 1<br />

40.50 21.50 9.00 AB TB-1<br />

WMT22AB225J MT22AB225J 2<br />

QS, QSH, QSHH,<br />

46.00 21.50 9.00 1-BC, 1-CA<br />

WMT22BC225J MT22BC225J 2<br />

HQS, HQSH, QP,<br />

QPH, HQP, HQPH,<br />

100k 46.00 21.50 9.00 1-AB, 1-CA<br />

WMT22CA225J MT22CA225J 2<br />

MP-T, MP-HT, MP-MT<br />

46.00 21.50 9.00 1-AB, 1-BC<br />

WMT32225J MT32225J 3 65.50 21.50 9.00<br />

3-phase, 4-wire SN, incoming and outgoing, test block bypass, 7-jaw sockets d<br />

1-AB, 1-BC,<br />

1-CA<br />

TB-2<br />

TB-3<br />

Max. tenant breaker (Amps): 225<br />

WMT13225J MT13225J 1<br />

40.50 25.50 9.00 — TB-4<br />

WMT23225J MT23225J 2<br />

QR2, QRH2,<br />

HQR2, HQR2H,<br />

100k 46.00 25.50 9.00 — TB-5<br />

MQ, MQH, MQL<br />

WMT33225J MT33225J 3 65.50 25.50 9.00 — TB-6<br />

a Dimensions shown are representative of outside<br />

box dimensions and do not include allowances for<br />

mounting bumps, hubs, or hardware protrusions.<br />

b Not for use on 3-phase,4-wire delta systems.<br />

c Max AIC determined by maximum AIC of tenant<br />

breakers when used in conjunction with a meter socket.<br />

d Rated for use with 240/120V Delta systems.<br />

Not field phaseable.<br />

f Field installable 5th Jaw Kit available (ECMT5).<br />

3-74<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Type WMT Test Block Bypass Meter Stacks: Knockout Diagrams<br />

Typical top view<br />

for NEMA 1<br />

WMT12225J<br />

WMT11225<br />

TB-1<br />

MT12225J<br />

MT11225<br />

TB-2<br />

WMT22AB225J MT22AB225J<br />

WMT22BC225J MT22BC225J<br />

3 METER<br />

CENTERS<br />

WMT22CA225J<br />

MT22CA225J<br />

WMT11225<br />

MT11225<br />

WMT31225<br />

TB-3<br />

MT31225<br />

WMT13225J<br />

TB-4<br />

WMT13225J<br />

WMT32225J<br />

MT32225J<br />

TB-5<br />

TB-6<br />

WMT23225J<br />

MT23225J<br />

WMT33225J<br />

MT33225J<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-75


Power Mod<br />

Revised on 06/30/19<br />

Type WMK K-Base Meter Stacks<br />

K-Base Meter Stacks<br />

Commercial K-Base Meter Stacks (type WMK) are<br />

designed to meet the requirements of those utilities<br />

specifying bolt-in meter sockets for 400 and<br />

600 Amp residential and commercial applications.<br />

3<br />

METER<br />

CENTERS<br />

Features include:<br />

n QuickSystem features<br />

n Exclusive Landis & Gyr K4, K5, and K7 meter<br />

sockets<br />

n 1 position K4, K5, K7 modules with 400 and<br />

600 Amp tenant mains<br />

n 2 position K7 module with 400 Amp tenant main<br />

n Space saving design<br />

K-Base quick reference<br />

n 400A and 600A 1-2 positions<br />

n 1200A horizontal bus rating<br />

n UL Standard # UL67<br />

n UL file # E27100<br />

n AIC Rating (25k)<br />

n Voltage<br />

– Single Phase 120/240V AC Max<br />

– Three In Single Phase Out 208Y/120V AC<br />

– Three Phase 240V AC Max<br />

n All swing latches and rivets are stainless steel<br />

n NEMA 3R rated<br />

n G90 Galvanized Steel<br />

n ANSI 61 Paint<br />

3-76<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 06/30/19<br />

Type WMK K-Base Meter Stacks<br />

n 400A and 600A<br />

1-2 positions<br />

n 1200A horizontal<br />

bus rating<br />

n AIC Rating (25k)<br />

3 METER<br />

CENTERS<br />

Commercial ringless type meter stacks: K-Base bolt-in, 25k AIC c f<br />

Catalog<br />

number<br />

Meter<br />

positions<br />

per stack<br />

Max.<br />

tenant breaker<br />

(Amps)<br />

Breaker<br />

provision d<br />

Maximum<br />

AIC Rating<br />

1-phase, 3-wire SN, incoming and outgoing, K4 K-Base bolt-in<br />

WMK11400R d 1 400<br />

JXD62B400<br />

Factory Inst.<br />

Dimensions (inches) a<br />

Height Width Depth<br />

25k 54.00 19.25 10.00 —<br />

WMK11600R g LXD62B600<br />

1 600<br />

25k 54.00 19.25 10.00 —<br />

Factory Inst.<br />

3-phase, 4-wire SN, incoming and 1-phase, 3-wire SN outgoing, K5 K-Base bolt-in b f<br />

WMK12400RJ d 1 400<br />

JXD62B400<br />

Factory Inst.<br />

Phase<br />

Knockout<br />

Diagram<br />

KB-1<br />

25k 54.00 19.25 10.00 AB KB-2<br />

JXD62B400<br />

WMK22400RJ 2 400<br />

25k 72.87 27.00 11.00 AC KB-3<br />

Factory Inst.<br />

3-phase, 4-wire SN, incoming and outgoing, K7 K-Base bolt-in e<br />

WMK13400RJ d 1<br />

JXD63B400<br />

54.00 19.25 10.00 — KB-2<br />

400<br />

25k<br />

WMK23400RJ d 2<br />

Factory Inst.<br />

72.88 27.00 11.00 — KB-3<br />

WMK13600RJ g 1 600<br />

LXD63B600<br />

Factory Inst.<br />

25k 54.00 19.25 10.00 — KB-2<br />

2 Meter Positions<br />

Per Stack<br />

Breaker<br />

Amperage<br />

Alternate amperage breakers<br />

Add<br />

Suffix<br />

<br />

1 Meter Position<br />

Per Stack<br />

T1<br />

T2<br />

T3<br />

T4<br />

T19<br />

T20<br />

Breaker<br />

Amperage<br />

200A<br />

250A<br />

300A<br />

350A<br />

450A<br />

500A<br />

Add<br />

Suffix<br />

<br />

T5<br />

T6<br />

T7<br />

T8<br />

T9<br />

T10<br />

T11<br />

T12<br />

T13<br />

T14<br />

T15<br />

T16<br />

T17<br />

200A/200A<br />

200A/250A<br />

200A/300A<br />

200A/350A<br />

200A/400A<br />

250A/300A<br />

250A/350A<br />

250A/400A<br />

300A/300A<br />

300A/350A<br />

300A/400A<br />

350A/350A<br />

350A/400A<br />

a Dimensions shown are representative of<br />

outside box dimensions and do not include<br />

allowances for mounting bumps, hubs, or<br />

hardware protrusions.<br />

b Not for use on 3-Phase 4-wire delta systems.<br />

c Max AIC determined by maximum AIC of<br />

tenant breakers when used in conjunction with<br />

a meter socket. Higher overall ratings may<br />

be achieved through approved series rating<br />

combinations.<br />

d Alternate amperage breakers are available.<br />

Please see table below for suffix that needs to<br />

be added for ordering. Extended leadtime may<br />

apply. Contact sales office for more details.<br />

e Rated for use with 240/120V Delta systems<br />

f Not field phaseable<br />

g Alternate amperage breakers are available<br />

(T19 and T20). Please see table at left for suffix<br />

that needs to be added for ordering. Extended<br />

leadtime may apply. Contact sales office for<br />

more details.<br />

T18<br />

250A/250A<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-77


Power Mod<br />

Type WMK K-Base Meter Stacks: Knockout Diagrams<br />

METER<br />

CENTERS<br />

3<br />

KB-1<br />

WMK11400R<br />

WMK11600R<br />

WMK12400RJ<br />

WMK13400RJ<br />

KB-2<br />

WMK13600RJ<br />

KB-3<br />

WMK22400RJ<br />

WMK23400RJ<br />

3-78<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 10/31/19<br />

Type WC House Power Module<br />

WC Series House Power Module<br />

Power Mod’s patented WC family of house<br />

power modules offers the ability to combine power<br />

distribution to branch circuits within a module that<br />

is connected directly to the horizontal bus. This<br />

reduces wall space needed, decreases labor and<br />

material cost (for installing a separate panel), and<br />

simplifies the electrical distribution system.<br />

Key Features of the WC family are:<br />

n Ring or Ringless Covers (horn bypass available<br />

with ringless)<br />

n Three or single phase horizontal bus with single<br />

phase output<br />

n 20 space, 40 circuit 100K AIC rated interior<br />

n Available subfeed breaker which can be used<br />

for large remote loads (such as elevators) or<br />

alternative energy inputs (solar)<br />

n Removable knock out plate<br />

n Load wires can exit out of the top, back, or bottom<br />

3 METER<br />

CENTERS<br />

The line of WC house power modules allow for<br />

un-precedented flexibility and savings. All of this<br />

while featuring the industry-leading QuickSystem<br />

that allows for the fastest install time.<br />

Series House Power Module quick reference<br />

n 1 Position, Single Phase Meter Socket<br />

n 250 Amp maximum rating per device.<br />

n 1200 Amp thru-bus rating<br />

n UL standard 67<br />

n UL file no. E27100<br />

n AIC rating: 100k<br />

n Voltage:<br />

– Single phase 120/240V AC max.<br />

– Three phase in single phase out<br />

● 120/208V AC max.<br />

● 240/120V AC max.<br />

n All swing latches and rivets are stainless steel.<br />

n Outdoor= NEMA 3R rated<br />

n 20 space, 40 circuit PL Series copper bus interior<br />

n G90 galvanized steel<br />

n ANSI 61 paint<br />

n Optional subfeed or alternative energy input (solar)<br />

up to 125amps.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-79


Power Mod<br />

Revised on 10/31/19<br />

Type WC House Power Module: Ring Style<br />

Main Features:<br />

n 1 Position, Single Phase<br />

Meter Socket<br />

n 250 Amp maximum rating per<br />

device. See below tables for<br />

breakdown of allowed amperages<br />

depending on the main and<br />

subfeed breaker combinations.<br />

n 1200 Amp horizontal bus rating<br />

3<br />

METER<br />

CENTERS<br />

Residential 4-Jaw Ring Type Meter-Loadcenter Stacks: 1-Phase, 3-wire, SN, Horizontal Bus, Distribution, and Subfeed<br />

Catalog<br />

Number<br />

Main Breaker -<br />

Distribution b<br />

Distribution<br />

Subfeed Breaker<br />

(Type HED4) b<br />

Maximum<br />

Dimensions (inches) a<br />

Amperage Type Spaces Circuits Amperage AIC Height Width Depth<br />

Knockout<br />

Diagram<br />

WC2040B1T1 225 HFXD6 20 40 N/A 100k 39.10 16.22 12.14 WC-1<br />

WC2040B1T2 200 HFXD6 20 40 50 100k 39.10 21.75 12.14<br />

WC2040B1T3 175 HFXD6 20 40 60 100k 39.10 21.75 12.14<br />

WC2040B1T4 175 HFXD6 20 40 70 100k 39.10 21.75 12.14<br />

WC2040B1T5 150 HFXD6 20 40 80 100k 39.10 21.75 12.14<br />

WC2040B1T6 150 HFXD6 20 40 90 100k 39.10 21.75 12.14<br />

WC-2<br />

WC2040B1T7 150 HFXD6 20 40 100 100k 39.10 21.75 12.14<br />

WC2040B1T8 150 HFXD6 20 40 110 100k 39.10 21.75 12.14<br />

WC2040B1T9 125 HFXD6 20 40 125 100k 39.10 21.75 12.14<br />

Residential 5-Jaw Ring Type Meter-Loadcenter Stacks: 3-Phase, 4-wire SN, Horizontal Bus and 1-Phase,<br />

3-wire, SN, Distribution and Subfeed<br />

Catalog<br />

Number<br />

Main Breaker -<br />

Distribution b<br />

Subfeed Breaker<br />

(Type HED4) b<br />

Distribution<br />

Max.<br />

Amperage Type Spaces Circuits Amperage AIC Height Width Depth<br />

Phasing c Diagram<br />

Dimensions (inches) Knockout<br />

WC2040B2T1J 225 HFXD6 20 40 N/A 100k 39.10 16.22 12.14 AC WC-1<br />

WC2040B2T2J 200 HFXD6 20 40 50 100k 39.10 21.75 12.14 AC<br />

WC2040B2T3J 175 HFXD6 20 40 60 100k 39.10 21.75 12.14 AC<br />

WC2040B2T4J 175 HFXD6 20 40 70 100k 39.10 21.75 12.14 AC<br />

WC2040B2T5J 150 HFXD6 20 40 80 100k 39.10 21.75 12.14 AC<br />

WC2040B2T6J 150 HFXD6 20 40 90 100k 39.10 21.75 12.14 AC<br />

WC-2<br />

WC2040B2T7J 150 HFXD6 20 40 100 100k 39.10 21.75 12.14 AC<br />

WC2040B2T8J 150 HFXD6 20 40 110 100k 39.10 21.75 12.14 AC<br />

WC2040B2T9J 125 HFXD6 20 40 125 100k 39.10 21.75 12.14 AC<br />

a Dimensions shown are representative of outside<br />

box dimensions and do not include allowances for<br />

mounting bumps, endwalls, covers, hubs, or hardware<br />

protrusions. Dimensions are subject to change.<br />

b Breakers are factory installed.<br />

c Can be re-phased in the field.<br />

3-80<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 10/31/19<br />

Type WC House Power Module: Ringless Style<br />

Main Features:<br />

n 1 Position, Single Phase<br />

Meter Socket<br />

n 250 Amp maximum rating per<br />

device. See below tables for<br />

breakdown of allowed amperages<br />

depending on the main and<br />

subfeed breaker combinations.<br />

n 1200 Amp horizontal bus rating<br />

Residential 4 or 5-Jaw Ringless Type Meter-Loadcenter Stacks: 1-Phase, 3-wire, SN, Horizontal Bus, Distribution, and Subfeed<br />

Catalog Number<br />

Main Breaker-<br />

Distribution b Distribution<br />

Subfeed Breaker<br />

(Type HED4) b<br />

Max. Dimensions a<br />

No bypass, 4J No bypass, 5J Horn Bypass, 5J Amp. Type Spaces Circuits Amperage AIC Height Width Depth<br />

Knockout<br />

Diagram<br />

WC2040B1T1R WC2040B1T1RJ WC2040B1T1RJB 225 HFXD6 20 40 N/A 100k 39.10 16.22 12.14 WC-1<br />

3 METER<br />

CENTERS<br />

WC2040B1T2R WC2040B1T2RJ WC2040B1T2RJB 200 HFXD6 20 40 50 100k 39.10 21.75 12.14<br />

WC2040B1T3R WC2040B1T3RJ WC2040B1T3RJB 175 HFXD6 20 40 60 100k 39.10 21.75 12.14<br />

WC2040B1T4R WC2040B1T4RJ WC2040B1T4RJB 175 HFXD6 20 40 70 100k 39.10 21.75 12.14<br />

WC2040B1T5R WC2040B1T5RJ WC2040B1T5RJB 150 HFXD6 20 40 80 100k 39.10 21.75 12.14<br />

WC2040B1T6R WC2040B1T6RJ WC2040B1T6RJB 150 HFXD6 20 40 90 100k 39.10 21.75 12.14<br />

WC-2<br />

WC2040B1T7R WC2040B1T7RJ WC2040B1T7RJB 150 HFXD6 20 40 100 100k 39.10 21.75 12.14<br />

WC2040B1T8R WC2040B1T8RJ WC2040B1T8RJB 150 HFXD6 20 40 110 100k 39.10 21.75 12.14<br />

WC2040B1T9R WC2040B1T9RJ WC2040B1T9RJB 125 HFXD6 20 40 125 100k 39.10 21.75 12.14<br />

Residential 5-Jaw Ringless Type Meter-Loadcenter Stacks: 3-Phase, 4-wire SN, Horizontal Bus and 1-Phase,<br />

3-wire, SN, Distribution and Subfeed<br />

Subfeed<br />

Breaker<br />

(Type HED4) b<br />

Catalog Number<br />

Main Breaker-<br />

Distribution b Distribution<br />

Max.<br />

No bypass Horn Bypass Amp. Type Spaces Circuits Amperage AIC Height Width Depth<br />

Dimensions a Phasing c Knockout<br />

Diagram<br />

WC2040B2T1RJ WC2040B2T1RJB 225 HFXD6 20 40 N/A 100k 39.10 16.22 12.14 AC WC-1<br />

WC2040B2T2RJ WC2040B2T2RJB 200 HFXD6 20 40 50 100k 39.10 21.75 12.14 AC<br />

WC2040B2T3RJ WC2040B2T3RJB 175 HFXD6 20 40 60 100k 39.10 21.75 12.14 AC<br />

WC2040B2T4RJ WC2040B2T4RJB 175 HFXD6 20 40 70 100k 39.10 21.75 12.14 AC<br />

WC2040B2T5RJ WC2040B2T5RJB 150 HFXD6 20 40 80 100k 39.10 21.75 12.14 AC<br />

WC2040B2T6RJ WC2040B2T6RJB 150 HFXD6 20 40 90 100k 39.10 21.75 12.14 AC<br />

WC-2<br />

WC2040B2T7RJ WC2040B2T7RJB 150 HFXD6 20 40 100 100k 39.10 21.75 12.14 AC<br />

WC2040B2T8RJ WC2040B2T8RJB 150 HFXD6 20 40 110 100k 39.10 21.75 12.14 AC<br />

WC2040B2T9RJ WC2040B2T9RJB 125 HFXD6 20 40 125 100k 39.10 21.75 12.14 AC<br />

a Dimensions shown are representative of outside<br />

box dimensions and do not include allowances for<br />

mounting bumps, endwalls, covers, hubs, or hardware<br />

protrusions. Dimensions are subject to change.<br />

b Breakers are factory installed.<br />

c Can be re-phased in the field.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-81


Power Mod<br />

Type WC House Power Module: Knockout Diagrams<br />

METER<br />

CENTERS<br />

3<br />

WC-1<br />

WC-2<br />

WC2040B1T1<br />

WC2040B1T1R<br />

WC2040B1T1RJ<br />

WC2040B1T1RJB<br />

KO Chart<br />

WC2040B2T1J<br />

WC2040B2T1RJ<br />

WC2040B2T1RJB<br />

DESIGNATION KO SIZE QTY<br />

A 2-1/2, 2, 1-1/2, 1-1/4, 1" 4<br />

B 1, 3/4, 1/2" 2<br />

C 3/4, 1/2" 14<br />

D 1/2" 8<br />

WC2040B1T2<br />

WC2040B1T2R<br />

WC2040B1T3<br />

WC2040B1T3R<br />

WC2040B1T4<br />

WC2040B1T4R<br />

WC2040B1T5<br />

WC2040B1T5R<br />

WC2040B1T6<br />

WC2040B1T6R<br />

WC2040B1T7<br />

WC2040B1T7R<br />

WC2040B1T8<br />

WC2040B1T8R<br />

WC2040B1T9<br />

WC2040B1T9R<br />

WC2040B1T2RJJ<br />

WC2040B1T2RJB<br />

WC2040B1T3RJ<br />

WC2040B1T3RJB<br />

WC2040B1T4RJ<br />

WC2040B1T4RJB<br />

WC2040B1T5RJ<br />

WC2040B1T5RJB<br />

WC2040B1T6RJ<br />

WC2040B1T6RJB<br />

WC2040B1T7RJ<br />

WC2040B1T7RJB<br />

WC2040B1T8RJ<br />

WC2040B1T8RJB<br />

WC2040B1T9RJ<br />

WC2040B1T9RJB<br />

WC2040B2T2J<br />

WC2040B2T2RJ<br />

WC2040B2T2RJB<br />

WC2040B2T3J<br />

WC2040B2T3RJ<br />

WC2040B2T3RJB<br />

WC2040B2T4J<br />

WC2040B2T4RJ<br />

WC2040B2T4RJB<br />

WC2040B2T5J<br />

WC2040B2T5RJ<br />

WC2040B2T5RJB<br />

WC2040B2T6J<br />

WC2040B2T6RJ<br />

WC2040B2T6RJB<br />

WC2040B2T7J<br />

WC2040B2T7RJ<br />

WC2040B2T7RJB<br />

WC2040B2T8J<br />

WC2040B2T8RJ<br />

WC2040B2T8RJB<br />

WC2040B2T9J<br />

WC2040B2T9RJ<br />

WC2040B2T9RJB<br />

3-82<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 10/31/19<br />

Type WCL Lever Bypass House Power Module<br />

WCL Series House Power Module<br />

Power Mod’s patented WCL (lever bypass) family of house<br />

power modules offers the ability to combine power distribution<br />

to branch circuits within a module that is connected directly to<br />

the horizontal bus. This reduces wall space needed, decreases<br />

labor and material cost (for installing a separate panel), and<br />

simplifies the electrical distribution system.<br />

Key Features of the WCL family are:<br />

n Talon HQ Lever Bypass ringless meter socket<br />

n Phasing:<br />

– Single phase horizontal bus with single phase HQ socket<br />

and 20 space 40 circuit PL Series copper interior<br />

– Three phase horizontal bus with single phase HQ socket<br />

(phased AC) and 20 space 40 circuit PL Series copper<br />

interior<br />

– Three phase horizontal bus with three phase HQ socket<br />

and 24 space 42 circuit PL Series copper interior<br />

n 100K AIC<br />

n Available subfeed breaker which can be used for large<br />

remote loads (such as elevators) or alternative energy inputs<br />

(solar)<br />

n Removable knock out plate<br />

n Load wires can exit out of the top, back, or bottom<br />

The line of WCL house power modules allow for un-precedented<br />

flexibility and savings. All of this while featuring the industryleading<br />

QuickSystem that allows for the fastest install time.<br />

3 METER<br />

CENTERS<br />

Lever Bypass Series House Power Module<br />

quick reference<br />

n Voltage<br />

– Single Phase 120/240V AC Max<br />

n Talon HQ Lever Bypass Meter Socket<br />

n 1 Position, Single Phase Meter Socket<br />

n 250 Amp maximum rating per device<br />

n 1200A horizontal bus rating<br />

n UL Standard # UL67<br />

n UL file # E27100<br />

n AIC rating 100K<br />

n Voltage<br />

– Single phase 120/240V AC max<br />

– Three phase<br />

● 120/208V AC max.<br />

● 240/120V AC max.<br />

n All swing latches and rivets are stainless steel.<br />

n Outdoor= NEMA 3R rated<br />

n Interiors: 20 space/40 circuit single phase or 24 space 42<br />

circuit three phase PL Series copper bus<br />

n G90 Galvanized Steel<br />

n ANSI 61 Paint<br />

n Optional subfeed or alternative energy input (solar) up to<br />

125 Amps<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-83


Power Mod<br />

Revised on 10/31/19<br />

Type WCL Lever Bypass House Power Module<br />

Main Features:<br />

n Talon HQ Lever Bypass Meter Socket<br />

n 1 Position, Single Phase Meter Socket<br />

n 250amp maximum rating per device.<br />

See below tables for breakdown of<br />

allowed amperages depending on the<br />

main and subfeed breaker combinations<br />

n 1200A horizontal bus rating<br />

METER<br />

CENTERS<br />

3<br />

Residential 4 or 5-Jaw Ringless Type Meter-Loadcenter Stacks: 1-Phase, 3-wire, SN, Horizontal Bus, Distribution, and Subfeed<br />

Main Breaker-<br />

Distribution b<br />

Distribution<br />

Subfeed Breaker<br />

(Type HED4) b<br />

Max. Dimensions a<br />

Knockout<br />

Catalog Number Amperage Type Spaces Circuits Amperage AIC Height Width Depth Diagram<br />

WCL2040B1T1RJ 225 HFXD6 20 40 N/A 100k 44.63 17.93 12.14 WCL-1<br />

WCL2040B1T2RJ 200 HFXD6 20 40 50 100k 44.63 22.35 12.14<br />

WCL2040B1T3RJ 175 HFXD6 20 40 60 100k 44.63 22.35 12.14<br />

WCL2040B1T4RJ 175 HFXD6 20 40 70 100k 44.63 22.35 12.14<br />

WCL2040B1T5RJ 150 HFXD6 20 40 80 100k 44.63 22.35 12.14<br />

WCL2040B1T6RJ 150 HFXD6 20 40 90 100k 44.63 22.35 12.14<br />

WCL-2<br />

WCL2040B1T7RJ 150 HFXD6 20 40 100 100k 44.63 22.35 12.14<br />

WCL2040B1T8RJ 150 HFXD6 20 40 110 100k 44.63 22.35 12.14<br />

WCL2040B1T9RJ 125 HFXD6 20 40 125 100k 44.63 22.35 12.14<br />

Commercial 5-Jaw Ringless Type-Lever Bypass Meter-Loadcenter Stacks: 3-Phase, 4-wire SN,<br />

Horizontal Bus and 1-Phase, 3-wire, SN, Distribution and Subfeed<br />

Main Breaker-<br />

Distribution b<br />

Distribution<br />

Subfeed Breaker<br />

(Type HED4) b<br />

Max.<br />

Catalog Number Amperage Type Spaces Circuits Amperage AIC Height Width Depth Phasing c Knockout<br />

Diagram<br />

WCL2040B2T1RJ 225 HFXD6 20 40 N/A 100k 44.63 17.93 12.14 AC WCL-1<br />

WCL2040B2T2RJ 200 HFXD6 20 40 50 100k 44.63 22.35 12.14 AC<br />

WCL2040B2T3RJ 175 HFXD6 20 40 60 100k 44.63 22.35 12.14 AC<br />

WCL2040B2T4RJ 175 HFXD6 20 40 70 100k 44.63 22.35 12.14 AC<br />

WCL2040B2T5RJ 150 HFXD6 20 40 80 100k 44.63 22.35 12.14 AC<br />

WCL2040B2T6RJ 150 HFXD6 20 40 90 100k 44.63 22.35 12.14 AC<br />

WCL-2<br />

WCL2040B2T7RJ 150 HFXD6 20 40 100 100k 44.63 22.35 12.14 AC<br />

WCL2040B2T8RJ 150 HFXD6 20 40 110 100k 44.63 22.35 12.14 AC<br />

WCL2040B2T9RJ 125 HFXD6 20 40 125 100k 44.63 22.35 12.14 AC<br />

Commercial 7-Jaw Ringless Type-Lever Bypass Meter-Loadcenter Stacks: 3-Phase, 4-wire SN,<br />

Horizontal Bus, Distribution and Subfeed<br />

Main Breaker-<br />

Distribution b<br />

Distribution<br />

Subfeed Breaker<br />

(Type HED4) b<br />

Max.<br />

Catalog Number Amperage Type Spaces Circuits Amperage AIC Height Width Depth Phasing c Knockout<br />

Diagram<br />

WCL2442B3T1RJ 225 HFXD6 24 42 N/A 100k 44.63 17.93 12.14 AC WCL-1<br />

WCL2442B3T2RJ 200 HFXD6 24 42 50 100k 44.63 22.35 12.14 AC<br />

WCL2442B3T3RJ 175 HFXD6 24 42 60 100k 44.63 22.35 12.14 AC<br />

WCL2442B3T4RJ 175 HFXD6 24 42 70 100k 44.63 22.35 12.14 AC<br />

WCL2442B3T5RJ 150 HFXD6 24 42 80 100k 44.63 22.35 12.14 AC<br />

WCL2442B3T6RJ 150 HFXD6 24 42 90 100k 44.63 22.35 12.14 AC<br />

WCL-2<br />

WCL2442B3T7RJ 150 HFXD6 24 42 100 100k 44.63 22.35 12.14 AC<br />

WCL2442B3T8RJ 150 HFXD6 24 42 110 100k 44.63 22.35 12.14 AC<br />

WCL2442B3T9RJ 125 HFXD6 24 42 125 100k 44.63 22.35 12.14 AC<br />

a Dimensions shown are representative of outside box<br />

dimensions and do not include allowances for mounting<br />

bumps, endwalls, covers, hubs, or hardware protrusions.<br />

Dimensions are subject to change.<br />

b Breakers are factory installed.<br />

c Cannot be re-phased in the field.<br />

3-84<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Type WCL Lever Bypass House Power Module: Knockout Diagrams<br />

3 METER<br />

CENTERS<br />

WCL-1<br />

WCL-2<br />

WCL2040B1T1RJ<br />

WCL2040B2T1RJ<br />

WCL2040B3T1RJ<br />

Knockout Chart<br />

WCL2040B1T2RJ<br />

WCL2040B1T3RJ<br />

WCL2040B1T4RJ<br />

WCL2040B1T5RJ<br />

WCL2040B1T6RJ<br />

WCL2040B1T7RJ<br />

WCL2040B1T8RJ<br />

WCL2040B1T9RJ<br />

WCL2040B2T2RJ<br />

WCL2040B2T3RJ<br />

WCL2040B2T4RJ<br />

WCL2040B2T5RJ<br />

WCL2040B2T6RJ<br />

WCL2040B2T7RJ<br />

WCL2040B2T8RJ<br />

WCL2040B2T9RJ<br />

WCL2040B3T2RJ<br />

WCL2040B3T3RJ<br />

WCL2040B3T4RJ<br />

WCL2040B3T5RJ<br />

WCL2040B3T6RJ<br />

WCL2040B3T7RJ<br />

WCL2040B3T8RJ<br />

WCL2040B3T9RJ<br />

DESIGNATION KO SIZE QTY<br />

A 2-1/2, 2, 1-1/2, 1-1/4, 1" 4<br />

B 1, 3/4, 1/2" 2<br />

C 3/4, 1/2" 14<br />

D 1/2" 8<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-85


Power Mod<br />

Revised on 10/31/19<br />

Type WCT Test Block Bypass House Power Module<br />

WCT Series House Power Module<br />

Power Mod’s patented WCT (test-block bypass) family of house<br />

power modules offers the ability to combine power distribution to<br />

branch circuits within a module that is connected directly to the thru<br />

bus. This reduces wall space needed, decreases labor and material<br />

cost (for installing a separate panel), and simplifies the electrical<br />

distribution system.<br />

3<br />

METER<br />

CENTERS<br />

Key Features of the WCT family are:<br />

n Siemens SMM Switchboard ring-style meter socket<br />

n Phasing:<br />

– Single phase horizontal bus with a single phase meter socket and<br />

20 space 40 circuit PL Series copper interior<br />

– Three phase horizontal bus with a single phase meter socket<br />

(phased AC) and 20 space 40 circuit PL Series copper interior<br />

– Three phase horizontal bus with three phase meter socket and<br />

24 space 42 circuit PL Series copper interior<br />

n 100K AIC<br />

n Available subfeed breaker which can be used for large remote loads<br />

(such as elevators) or alternative energy inputs (solar)<br />

n Removable knock out plate<br />

n Load wires can exit out of the top, back, or bottom<br />

The line of WCT house power modules allow for un-precedented flexibility<br />

and savings. All of this while featuring the industry-leading<br />

QuickSystem that allows for the fastest install time.<br />

Test Block Bypass Series House Power Module Quick Reference<br />

n Siemens SMM Switchboard ring-style<br />

n 1 position, Single Phase Meter Socket<br />

n 250amp, maximum rating per device<br />

n 1200amp horizontal bus rating<br />

n UL standard #'s UL 67<br />

n UL file # E270100<br />

n AIC rating 100K<br />

n Voltage<br />

– 1 phase 120/240V AC max<br />

– 3 phase 120/208V AC max<br />

– 3 phase 240/120V AC max<br />

n All swing latches and rivets are stainless steel<br />

n Outdoor= NEMA 3R rated<br />

n Interiors:<br />

– 20 spaces/40 circuits single phase<br />

– 24 spaces/42 circuits 3 phase PL Series copper bus<br />

n G90 galvanized steel<br />

n ANSI 61 paint<br />

n Optional subfeed or alternative energy input (solar) up to 125amps<br />

n EUSERC drawing #'s 312 and 353<br />

3-86<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 10/31/19<br />

Type WCT Test Block Bypass House Power Module<br />

Main Features:<br />

n Siemens SMM Switchboard ring-style<br />

n 1 Position, Single Phase Meter Socket<br />

n 250amp maximum rating per device.<br />

See below tables for breakdown of<br />

allowed amperages depending on the<br />

main and subfeed breaker combinations.<br />

n 1200 Amp horizontal bus rating.<br />

Commercial 4-Jaw Ring Type-Test Block Bypass Meter-Loadcenter Stacks: 1-Phase, 3-wire, SN,<br />

Horizontal Bus, Distribution, and Subfeed<br />

Main Breaker-<br />

Distribution b<br />

Distribution<br />

Subfeed Breaker<br />

(Type HED4) b<br />

Max.<br />

Dimensions a<br />

Knockout<br />

Catalog Number Amperage Type Spaces Circuits Amperage AIC Height Width Depth Diagram<br />

WCT2040B1T1 225 HFXD6 20 40 N/A 100k 52.1 18.42 12.14 WCT-1<br />

WCT2040B1T2 200 HFXD6 20 40 50 100k 52.1 18.42 12.14<br />

WCT2040B1T3 175 HFXD6 20 40 60 100k 52.1 18.42 12.14<br />

WCT2040B1T4 175 HFXD6 20 40 70 100k 52.1 18.42 12.14<br />

WCT2040B1T5 150 HFXD6 20 40 80 100k 52.1 18.42 12.14<br />

WCT2040B1T6 150 HFXD6 20 40 90 100k 52.1 18.42 12.14<br />

WCT-2<br />

WCT2040B1T7 150 HFXD6 20 40 100 100k 52.1 18.42 12.14<br />

WCT2040B1T8 150 HFXD6 20 40 110 100k 52.1 18.42 12.14<br />

WCT2040B1T9 125 HFXD6 20 40 125 100k 52.1 18.42 12.14<br />

3 METER<br />

CENTERS<br />

Dimensions a<br />

Commercial 5-Jaw Ring Type-Test Block Bypass Meter-Loadcenter Stacks: 3-Phase, 4-wire SN,<br />

Horizontal Bus and 1-Phase, 3-wire, SN, Distribution and Subfeed<br />

Main Breaker-<br />

Distribution b Distribution<br />

Subfeed Breaker<br />

(Type HED4) b<br />

Max.<br />

Catalog Number Amperage Type Spaces Circuits Amperage AIC Height Width Depth Phasing c Knockout<br />

Diagram<br />

WCT2040B2T1J 225 HFXD6 20 40 N/A 100k 52.1 18.42 12.14 AC WCT-1<br />

WCT2040B2T2J 200 HFXD6 20 40 50 100k 52.1 18.42 12.14 AC<br />

WCT2040B2T3J 175 HFXD6 20 40 60 100k 52.1 18.42 12.14 AC<br />

WCT2040B2T4J 175 HFXD6 20 40 70 100k 52.1 18.42 12.14 AC<br />

WCT2040B2T5J 150 HFXD6 20 40 80 100k 52.1 18.42 12.14 AC<br />

WCT2040B2T6J 150 HFXD6 20 40 90 100k 52.1 18.42 12.14 AC<br />

WCT-2<br />

WCT2040B2T7J 150 HFXD6 20 40 100 100k 52.1 18.42 12.14 AC<br />

WCT2040B2T8J 150 HFXD6 20 40 110 100k 52.1 18.42 12.14 AC<br />

WCT2040B2T9J 125 HFXD6 20 40 125 100k 52.1 18.42 12.14 AC<br />

Dimensions a<br />

Commercial 7-Jaw Ring Type-Test Block Bypass Meter-Loadcenter Stacks: 3-Phase, 4-wire SN,<br />

Horizontal Bus, Distribution and Subfeed<br />

Main Breaker-<br />

Distribution b<br />

Distribution<br />

Subfeed Breaker<br />

(Type HED4) b<br />

Max.<br />

Catalog Number Amperage Type Spaces Circuits Amperage AIC Height Width Depth Phasing c Knockout<br />

Diagram<br />

WCT2442B3T1J 225 HFXD6 24 42 N/A 100k 52.1 18.42 12.14 AC WCT-1<br />

WCT2442B3T2J 200 HFXD6 24 42 50 100k 52.1 18.42 12.14 AC<br />

WCT2442B3T3J 175 HFXD6 24 42 60 100k 52.1 18.42 12.14 AC<br />

WCT2442B3T4J 175 HFXD6 24 42 70 100k 52.1 18.42 12.14 AC<br />

WCT2442B3T5J 150 HFXD6 24 42 80 100k 52.1 18.42 12.14 AC<br />

WCT2442B3T6J 150 HFXD6 24 42 90 100k 52.1 18.42 12.14 AC<br />

WCT-2<br />

WCT2442B3T7J 150 HFXD6 24 42 100 100k 52.1 18.42 12.14 AC<br />

WCT2442B3T8J 150 HFXD6 24 42 110 100k 52.1 18.42 12.14 AC<br />

WCT2442B3T9J 125 HFXD6 24 42 125 100k 52.1 18.42 12.14 AC<br />

a Dimensions shown are representative of outside<br />

box dimensions and do not include allowances for<br />

mounting bumps, endwalls, covers, hubs, or hardware<br />

protrusions. Dimensions are subject to change.<br />

b Breakers are factory installed.<br />

c Cannot be re-phased in the field.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-87


Power Mod<br />

Type WCT Test Block Bypass House Power Module: Knockout Diagrams<br />

METER<br />

CENTERS<br />

3<br />

WCT-1<br />

WCT-2<br />

WCT2040B1T1<br />

WCT2040B2T1J<br />

WCT2040B3T1J<br />

Knockout Chart<br />

WCT2040B1T2<br />

WCT2040B1T3<br />

WCT2040B1T4<br />

WCT2040B1T5<br />

WCT2040B1T6<br />

WCT2040B1T7<br />

WCT2040B1T8<br />

WCT2040B1T9<br />

WCT2040B2T2J<br />

WCT2040B2T3J<br />

WCT2040B2T4J<br />

WCT2040B2T5J<br />

WCT2040B2T6J<br />

WCT2040B2T7J<br />

WCT2040B2T8J<br />

WCT2040B2T9J<br />

WCT2442B3T2J<br />

WCT2442B3T3J<br />

WCT2442B3T4J<br />

WCT2442B3T5J<br />

WCT2442B3T6J<br />

WCT2442B3T7J<br />

WCT2442B3T8J<br />

WCT2442B3T9J<br />

DESIGNATION KO SIZE QTY<br />

A 2-1/2, 2, 1-1/2, 1-1/4, 1" 4<br />

B 1, 3/4, 1/2" 2<br />

C 3/4, 1/2" 14<br />

D 1/2" 8<br />

3-88<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 11/30/20<br />

Type WSPD Surge Protection Modules<br />

WSPD Surge Protection Modules<br />

Surge protection modules for Power Mod (type<br />

WSPD) are horizontal bus connected modules that<br />

allow the user to view surge status as well as access<br />

the SPD control panel without breaking the utility seal<br />

on the enclosure. An optional breaker disconnect is<br />

available to enable the end user to replace the SPD<br />

(surge protection device) without having to disconnect<br />

utility power to the Power Mod installation.<br />

Features include:<br />

n QuickSystem features<br />

n 35, 50, 60, 65, 100, 140, 200, 300, 400, 500kA<br />

ratings available<br />

n External, vandal resistant and lockable clear cover<br />

over SPD control panel<br />

n Single phase horizontal bus and three phase<br />

horizontal bus<br />

n Optional breaker disconnect that opens phase and<br />

neutral to make SPD replacement quick and easy<br />

n Skinny, selectable SPD option available with internal<br />

and external mounting<br />

3 METER<br />

CENTERS<br />

Surge Protection Module quick reference<br />

n 35kA – 500kA kA rating<br />

n 1200amp horizontal bus rating<br />

n UL standard #67<br />

n UL file # E27100<br />

n AIC rating: 65kA and 100kA<br />

n Voltage<br />

– Single phase 120/240V AC max<br />

– Three phase 240V AC max<br />

n All swing latches and rivets are stainless steel<br />

n NEMA 3R rated<br />

n ANSI 61 paint<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-89


Power Mod<br />

Revised on 06/30/19<br />

Type WSPD Surge Protection Modules<br />

Main Features:<br />

n 100-500kA ratings<br />

n 1200 amp horizontal<br />

bus rating<br />

n Suitable for 100k<br />

AIC applications<br />

Lugs not required.<br />

METER<br />

CENTERS<br />

3<br />

1-phase, 3-wire SN, 120/240V AC<br />

Catalog Number<br />

(with HEG Breaker<br />

Disconnect)<br />

Catalog Number<br />

(no disconnect)<br />

Breaker<br />

Type<br />

kA Surge<br />

Dimensions (inches) a Knockout<br />

Current b Height Width Depth Diagram<br />

WSPD1B10A WSPD1N10A HEG 100 29.19 13.38 7.91<br />

WSPD1B20A WSPD1N20A HEG 200 29.19 13.38 7.91<br />

WSPD1B30A WSPD1N30A HEG 300 29.19 13.38 7.91<br />

WSPD-B = Breaker<br />

WSPD-N = No breaker<br />

WSPD1B40A WSPD1N40A HEG 400 29.19 13.38 7.91<br />

WSPD1B50A WSPD1N50A HEG 500 29.19 13.38 7.91<br />

3-phase, 4-wire SN, Delta 240/120V AC<br />

Catalog Number<br />

(with HEG Breaker<br />

Disconnect)<br />

Catalog Number<br />

(no disconnect)<br />

Breaker<br />

Type<br />

a kA Surge<br />

Dimensions (inches)<br />

Knockout<br />

Current b Height Width Depth Diagram<br />

WSPD3B10B WSPD3N10B HEG 100 29.19 13.38 7.91<br />

WSPD3B20B WSPD3N20B HEG 200 29.19 13.38 7.91<br />

WSPD3B30B WSPD3N30B HEG 300 29.19 13.38 7.91<br />

WSPD-B = Breaker<br />

WSPD-N = No breaker<br />

WSPD3B40B WSPD3N40B HEG 400 29.19 13.38 7.91<br />

WSPD3B50B WSPD3N50B HEG 500 29.19 13.38 7.91<br />

3-phase, 4-wire SN, Wye 208/120V AC<br />

Catalog Number<br />

(with HEG Breaker<br />

Disconnect)<br />

Catalog Number<br />

(no disconnect)<br />

Breaker<br />

Type<br />

kA Surge<br />

Dimensions (inches) a Knockout<br />

Current b Height Width Depth Diagram<br />

WSPD3B10C WSPD3N10C HEG 100 29.19 13.38 7.91<br />

WSPD3B20C WSPD3N20C HEG 200 29.19 13.38 7.91<br />

WSPD3B30C WSPD3N30C HEG 300 29.19 13.38 7.91<br />

WSPD-B = Breaker<br />

WSPD-N = No breaker<br />

WSPD3B40C WSPD3N40C HEG 400 29.19 13.38 7.91<br />

WSPD3B50C WSPD3N50C HEG 500 29.19 13.38 7.91<br />

a Dimensions shown are representative of outside box<br />

dimensions and do not include allowances for mounting<br />

bumps, endwalls, covers, hubs, or hardware protrusions.<br />

Dimensions are subject to change.<br />

b 200 - 500kA devices requite additional lead time.<br />

Please contact sales office for details on lead time.<br />

3-90<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Type WSPD Surge Protection Modules: Knockout Diagrams<br />

3 METER<br />

CENTERS<br />

WSPD1B10A<br />

WSPD1B20A<br />

WSPD1B30A<br />

WSPD1B40A<br />

WSPD1B50A<br />

WSPD-B<br />

WSPD3B10B<br />

WSPD3B10C<br />

WSPD3B20B<br />

WSPD3B20C<br />

WSPD3B30B<br />

WSPD3B30C<br />

WSPD3B40B<br />

WSPD3B40C<br />

WSPD3B50B<br />

WSPD3B50C<br />

With breaker disconnect<br />

WSPD1N10A<br />

WSPD1N20A<br />

WSPD1N30A<br />

WSPD1N40A<br />

WSPD1N50A<br />

WSPD-N<br />

WSPD3N10B<br />

WSPD3N10C<br />

WSPD3N20B<br />

WSPD3N20C<br />

WSPD3N30B<br />

WSPD3N30C<br />

WSPD3N40B<br />

WSPD3N40C<br />

WSPD3N50B<br />

WSPD3N50C<br />

No breaker disconnect<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-91


Power Mod<br />

Revised on 11/30/20<br />

Type Skinny WSPD Surge Protection Enclosure<br />

Skinny WSPD Surge Protection Enclosure<br />

Flexible surge protection in a small footprint. Choose desired<br />

Surge Protection Device to be paired with the Skinny WSPD<br />

enclosure. (SPD sold separately)<br />

3<br />

METER<br />

CENTERS<br />

Space Saving Selectable Surge Protection:<br />

n 35 – 100kA Surge Current Protection<br />

n Single and Three Phase<br />

n NEMA 3R Outdoor Enclosure<br />

n 1200 amp horizontal bus rating<br />

n Suitable for 65k AIC applications<br />

Skinny WSPD enclosure<br />

Catalog Number Amps Phase Enclosure Type Short Circuit Current Rating<br />

WSPD1N 1200 1 NEMA 3R (Outdoor) 65kA<br />

WSPD3N 1200 3 NEMA 3R (Outdoor) 65kA<br />

Single Phase SPD Options<br />

Three Phase SPD Options<br />

SPD Type 1<br />

Catalog Number Surge Current Rating Installation<br />

TPS3A030500 50kA External a<br />

TPS3A03050N 50kA (N-G)P External a<br />

TPS3A0305D0 50kA DRY External a<br />

TPS3A0305DN 50kA DRY (N-G)P External a<br />

TPS3A0910000 100kA External a<br />

TPS3A091000E 100kA EIL External a<br />

TPS3A0910D00 100kA DRY External a<br />

TPS3A0910D0E 100kA DRY EIL External a<br />

QSPD2A035B 35kA Internal c<br />

QSPD2A065P 65kA Internal c<br />

SPD Type 2<br />

Catalog Number Surge Current Rating Installation<br />

FS060 60kA External a<br />

FS100 100kA External a<br />

SPD Type 1<br />

Catalog Number Surge Current Rating Installation<br />

TPS3B030500 50kA 240/120 3PH 4W Delta External b<br />

TPS3B03050N 50kA (N-G)P 240/120 3PH 4W Delta External b<br />

TPS3B0305D0 50kA DRY 240/120 3PH 4W Delta External b<br />

TPS3B0305DN 50kA DRY (N-G)P 240/120 3PH 4W Delta External b<br />

TPS3C030500 50kA 208Y/120V 3PH 4W External b<br />

TPS3C03050N 50kA (N-G)P 208Y/120V 3PH 4W External b<br />

TPS3C0305D0 50kA DRY 208Y/120V 3PH 4W External b<br />

TPS3C0305DN 50kA DRY (N-G)P 208Y/120V 3PH 4W External b<br />

TPS3B0910000 100kA 240/120 3PH 4W Delta External b<br />

TPS3B091000E 100kA EIL 240/120 3PH 4W Delta External b<br />

TPS3B0910D00 100kA DRY 240/120 3PH 4W Delta External b<br />

TPS3B0910D0E 100kA DRY EIL 240/120 3PH 4W Delta External b<br />

TPS3C0910000 100kA 208Y/120V 3PH 4W External b<br />

TPS3C091000E 100kA EIL 208Y/120V 3PH 4W External b<br />

TPS3C0910D00 100kA DRY 208Y/120V 3PH 4W External b<br />

TPS3C0910D0E 100kA DRY EIL 208Y/120V 3PH 4W External b<br />

QSPD3B065 65kA 240/120 3PH 4W Delta Internal c<br />

QSPD3C065 65kA 208Y/120V 3PH 4W Internal c<br />

Enclosure with<br />

Boltshield installed.<br />

SPD sold separately.<br />

Enclosure with circuit<br />

breaker and TPS3 installed.<br />

SPD sold separately<br />

a SPD is mounted externally and connected to the bus<br />

via a Q230HH circuit breaker purchased separately and<br />

installed in this unit. Install the SPD in accordance with<br />

standard practices to ensure watertight connections.<br />

Conduit and fittings must be purchased separately.<br />

b SPD is mounted externally and connected to the bus<br />

via a Q330HH circuit breaker purchased separately and<br />

installed in this unit. Install the SPD in accordance with<br />

standard practices to ensure watertight connections.<br />

Conduit and fittings must be purchased separately.<br />

c SPD is a plug-on device installed directly on the mounting<br />

provisions in this unit.<br />

3-92<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 11/30/20<br />

Type Skinny WSPD Surge Protection Enclosure: Knockout Diagrams<br />

WSPD1N<br />

3 METER<br />

CENTERS<br />

WSPD3N<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-93


Power Mod<br />

Revised on 06/30/19<br />

Type WMN ConEd Residential Meter Stacks<br />

3<br />

WMN ConEd Residential<br />

Meter Stacks<br />

Siemens Consolidated Edison Residential Meter Stacks are<br />

packed with features inside and out; our exclusive knock<br />

out plate offers flexibility when pulling wires to the stack,<br />

moveable neutrals and grounds to save wire, and all of<br />

the QuickSystem features all designed with the contractor<br />

in mind. Features 10" socket center-to-center distance to<br />

allow use of meter pulling tools.<br />

METER<br />

CENTERS<br />

Surge Protection Module quick reference<br />

n 2-6 gang<br />

n 125/225 Amp per position<br />

n 1200Amp horizontal bus rating<br />

n UL standard 67<br />

n UL file no. E27100<br />

n AIC rating: (100K)<br />

n Voltage<br />

– 3 phase in single phase out<br />

– 240V AC max<br />

n All swing latches and rivets are stainless steel<br />

n Outdoor = NEMA 3R rated<br />

n Indoor = NEMA 1R rated<br />

n G90 galvanized steel<br />

n ANSI 61 paint<br />

3-94<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 06/30/19<br />

Type WMN ConEd Residential Meter Stacks<br />

Main Features:<br />

n 2-6 gang<br />

n 1200 amp horizontal<br />

bus rating<br />

n Suitable for 100k<br />

AIC applications<br />

3 METER<br />

CENTERS<br />

Residential 5-jaw ring type meter stacks; 3-phase, 4-wire SN, incoming and 1-phase, 3 wire SN outgoing c<br />

Outdoor<br />

Catalog<br />

number<br />

Indoor<br />

Catalog<br />

number<br />

Max. tenant breaker (Amps): 125<br />

Meter<br />

positions<br />

per stack<br />

WMN22125J MN22125J 2<br />

Breaker<br />

provision<br />

a Maximum<br />

Dimensions (inches)<br />

Knockout<br />

AIC Height Width Depth Diagram<br />

100k 35.31 12.97 8.09 WMN-1<br />

WMN32125J MN32125J 3 QP, QPH,<br />

100k 46.31 12.97 8.09 WMN-2<br />

WMN42125J MN42125J 4<br />

HQP, HQPH,<br />

MP-T, MP-HT,<br />

100k 56.31 12.97 8.09 WMN-3<br />

WMN52125J MN52125J 5 MPMT<br />

100k 66.31 12.97 8.09 WMN-4<br />

WMN62125J MN62125J 6 100k 76.31 12.97 8.09 WMN-5<br />

Max. tenant breaker (Amps): 225 b<br />

WMN22225J MN22225J 2<br />

100k 35.31 16.09 8.09 WMN-6<br />

WMN32225J<br />

WMN42225J<br />

WMN52225J<br />

MN32225J<br />

MN42225J<br />

MN52225J<br />

3<br />

4<br />

5<br />

QS, QSH, QSHH,<br />

HQS, HQSH,<br />

QP, QPH, HQP,<br />

HQPH, MP-T,<br />

MP-HT, MPMT<br />

100k<br />

100k<br />

100k<br />

46.31<br />

56.31<br />

66.31<br />

16.09<br />

16.09<br />

16.09<br />

8.09<br />

8.09<br />

8.09<br />

WMN-7<br />

WMN-8<br />

WMN-9<br />

WMN62225J MN62225J 6 100k 76.31 16.09 8.09 WMN-10<br />

Dimensions shown are representative of outside box<br />

dimensions and do not include allowances for mounting<br />

bumps, endwalls, covers, hubs, or hardware protrusions.<br />

Dimensions are subject to change.<br />

225A available in lower three positions only.<br />

200A continuous for all other positions.<br />

Must use QuickPhase features to route all sockets AWAY<br />

from high-leg when 240/120 Delta voltage is used.<br />

Max AIC determined by maximum AIC of tenant<br />

breakers.<br />

Install QP breakers below QS.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-95


Power Mod<br />

Type WMN ConEd Residential Meter Stacks: Knockout Diagrams<br />

WMN-1<br />

WMN22125J<br />

MN22125J<br />

WMN-2<br />

WMN32125J<br />

MN32125J<br />

WMN-3<br />

WMN42125J<br />

MN42125J<br />

METER<br />

CENTERS<br />

3<br />

125 Amp Typical Top View for NEMA 1<br />

WMN-4<br />

WMN52125J<br />

MN52125J<br />

WMN-5<br />

WMN52125J<br />

MN62125J<br />

125 Amp Typical Top View for NEMA 3R<br />

(6) CENTER PUNCH<br />

LOCATORS<br />

125 Amp Typical Bottom View<br />

(6) KOs 1, 1-1/4, 1-1/2, 2"<br />

3-96<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Type WMN ConEd Residential Meter Stacks: Knockout Diagrams<br />

WMN-6<br />

WMN22225J<br />

MN22225J<br />

WMN-7<br />

WMN32225J<br />

MN32225J<br />

WMN-8<br />

WMN42225J<br />

MN42225J<br />

3 METER<br />

CENTERS<br />

225 Amp Typical Top View for NEMA 1<br />

WMN-9<br />

WMN52225J<br />

MN52225J<br />

WMN-10<br />

WMN62225J<br />

MN62225J<br />

225 Amp Typical Top View for NEMA 3R<br />

225 Amp Typical Bottom View<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-97


Power Mod<br />

Revised on 06/30/19<br />

Type WTBN ConEd Tap boxes<br />

Type WTBN ConEd Tap boxes<br />

ConEd Tap Boxes (type WTBN) are designed to meet<br />

the requirements of the Consolidated Edison Utility<br />

service area. WTBN tap boxes feature a shallow<br />

depth for front and rear alignment with WMN stacks.<br />

3<br />

METER<br />

CENTERS<br />

ConEd Tap boxes<br />

n 400-1200A module rating<br />

n 1200Amp horizontal bus rating<br />

n UL standard # UL67<br />

n UL file no. E27100<br />

n AIC rating: (100K AIC)<br />

n Voltage<br />

– 3 phase in single phase out<br />

– 240V AC max<br />

n All swing latches and rivets are stainless steel<br />

n NEMA 3R rated<br />

n G90 galvanized steel<br />

n ANSI 61 paint<br />

3-98<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 06/30/19<br />

Type WTBN ConEd Tap boxes<br />

Main Features:<br />

n 400-1200A<br />

n 1200 amp horizontal<br />

bus rating<br />

n Suitable for 100k<br />

AIC applications<br />

3 METER<br />

CENTERS<br />

Tap Box modules: 3-phase, 4 wire SN, 208/120V AC Max<br />

Catalog number<br />

(100k AC)<br />

Catalog number<br />

(100k AC)<br />

Blank Endwall<br />

Ampere<br />

Rating<br />

a Service<br />

Dimensions (inches)<br />

Line Side Connections<br />

feed b Height Width Depth (Lugs)<br />

Knockout<br />

Diagram<br />

WTBN3400CU WTBN3400CUNH 400 OH/UG 48.81 17.63 8.063 1 Set Of 2 Studs WTBN-1<br />

WTBN3600CU WTBN3600CUNH 600 OH/UG 48.81 17.63 8.063 1 Set Of 2 Studs WTBN-2<br />

WTBN3800CU WTBN3800CUNH 800 OH/UG 52.84 25.63 8.094 2 Sets Of 2 Studs WTBN-3<br />

WTBN31200CU WTBN31200CUNH 1200 OH/UG 64.47 25.63 8.094 2 Sets Of 2 Studs WTBN-4<br />

a Dimensions shown are representative of outside box<br />

dimensions and do not include allowances for mounting<br />

bumps, endwalls, covers, hubs, or hardware protrusions.<br />

Dimensions are subject to change.<br />

b Devices have studs on top and bottom, but only one<br />

side should be used.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-99


Power Mod<br />

Type WTBN ConEd Tap boxes<br />

METER<br />

CENTERS<br />

3<br />

WTBN-1<br />

WTBN3400CU<br />

WTBN-2<br />

WTBN3600CU<br />

WTBN-3<br />

WTBN3800CU<br />

WTBN-4<br />

WTBN31200CU<br />

3-100<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 06/30/19<br />

WMMB Aux Pull Box<br />

Main Features:<br />

n EUSERC compliant<br />

incoming pull section<br />

n Dual cover handles<br />

n Single and three<br />

phase models<br />

n No horizontal bus<br />

n EUSERC drawing<br />

number 343 and 347<br />

EUSERC compliant pullbox modules: 1-phase, 3-wire SN, incoming , 120/240V AC max. c<br />

Catalog<br />

number<br />

Ampere<br />

rating<br />

Withstand<br />

rating b<br />

Service<br />

feed<br />

Dimensions (inches) a<br />

Height Width Depth<br />

KO<br />

drawing<br />

no.<br />

Line terminal lugs no.<br />

and size per line and netural<br />

Knockout<br />

Diagrams<br />

3 METER<br />

CENTERS<br />

WMMB1400 400 65,000 UG 37.50 16.69 9.34 P-1 1 set of 2 studs P-1<br />

WMMB1800 800 65,000 UG 45.50 19.44 12.72 P-2 1 set of 2 studs P-2<br />

WMMB11200 1200 65,000 UG 47.50 25.94 12.72 P-3 3 sets of 2 studs P-3<br />

EUSERC compliant pullbox modules: 3-phase, 4-wire SN, incoming, 240V AC max. c<br />

Catalog<br />

number<br />

Ampere<br />

rating<br />

Withstand<br />

rating b<br />

Service<br />

feed<br />

Dimensions (inches) a<br />

Height Width Depth<br />

KO<br />

drawing<br />

no.<br />

Line terminal lugs no.<br />

and size per line and netural<br />

Knockout<br />

Diagrams<br />

WMMB3400 400 65,000 UG 37.50 16.69 9.34 P-1 1 set of 2 studs P-1<br />

WMMB3800 800 65,000 UG 45.50 25.94 12.72 P-2 2 set of 2 studs P-2<br />

WMMB31200 1200 65,000 UG 47.50 33.83 12.72 P-3 3 sets of 2 studs P-3<br />

Please Note: As of 4/10/2019 the WMMB modules no longer<br />

come with the pass through bushing. If it is required please<br />

order it as a separate part. The pass through bushing part<br />

number is WMMBK<br />

a Dimensions shown are representative of outside box<br />

dimensions and do not include allowances for mounting<br />

bumps, endwalls, covers, hubs, or hardware protrusions.<br />

Dimensions are subject to change.<br />

b Devices rated for 22,000. 65,000 rating requires cables<br />

to be tied together. Please see instructions with pullbox<br />

for details.<br />

c Devices do not have horizontal bus.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-101


Power Mod<br />

WMMB Aux Pull Box: Knockout Diagrams<br />

METER<br />

CENTERS<br />

3<br />

W<br />

W<br />

P-1<br />

P-2<br />

P-3<br />

WMMB1400<br />

WMMB3400<br />

WMMB1800<br />

WMMB3800<br />

Width<br />

19.44<br />

25.94<br />

WMMB11200<br />

WMMB31200<br />

Width<br />

25.94<br />

33.83<br />

3-102<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 04/30/20<br />

Expandable Elbows and Spacers<br />

Expandable Elbows<br />

The new expandable elbow provides a never before seen level of flexibility for<br />

multifamily metering products. This elbow has telescoping sides that allow both<br />

sides of the device to be extended. Variable widths on these elbows allow the<br />

installer to get the installation just right when connecting two parts of a meter bank<br />

together via the use of a corner.<br />

3 METER<br />

CENTERS<br />

Elbow: Closed Position<br />

Expandable Spacers<br />

Elbow: Both Sides Expanded<br />

The expandable spacer is also a brand new arrival to the Power Mod product portfolio<br />

that works similar to the expandable elbow. Now electrical room installations can<br />

be designed for exact installation precision; the expandable spacer allows the<br />

installer to change the width of the meter bank spacer to an exact measurement.<br />

Flexability in Meter Bank<br />

Installations<br />

The diagram below shows how<br />

complex electrical rooms could be<br />

problematic when spacers and elbows<br />

do not have flexibility. In this example,<br />

an expandable spacer and expandable<br />

elbow can allow an engineer to design<br />

a meter bank installation on a jagged<br />

wall with all parts of the meter bank<br />

comfortably mounted on all walls<br />

without the need of additional strut or<br />

other artificial walls.<br />

WT<br />

WXB<br />

Spacer<br />

WMM<br />

WMM<br />

Inside<br />

Corner<br />

WMM x 3<br />

Outside<br />

Corner<br />

Top View<br />

Spacer: Closed Position<br />

Spacer: Both Sides Expanded<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-103


Power Mod<br />

Revised on 04/30/20<br />

Elbows and Spacers<br />

Elbows and Spacers<br />

Siemens offers a wide range of auxiliary<br />

modules to help product fit your application.<br />

All units come with appropriate hardware<br />

and instruction sheets for safe installation.<br />

Standard elbow<br />

3<br />

METER<br />

CENTERS<br />

12˝ to 18˝<br />

12˝ to 18˝<br />

Bussed Elbow and Bussed Extensions/Spacers<br />

NEMA 1<br />

Elbows<br />

NEMA 3R<br />

Elbows<br />

Bussed<br />

Extensions/<br />

Spacers<br />

12˝ to 18˝<br />

12˝ to 18˝<br />

12.06˝<br />

12.06˝<br />

12.06˝<br />

30.8˝<br />

30.8˝<br />

30.8˝<br />

15˝<br />

15˝<br />

12˝ to 18˝<br />

W<br />

BE1/BE4<br />

12˝ to 18˝<br />

ELBT118/ELBT318<br />

BE1/BE4<br />

15˝<br />

12˝ to 18˝<br />

W<br />

12˝ to 18˝<br />

W<br />

ELBT118/ELBT318<br />

ELBT118/ELBT318<br />

W<br />

D<br />

Inside Corner<br />

15˝<br />

6.5˝<br />

7.25˝<br />

6˝ to cross<br />

bus center<br />

Inside Corner<br />

8.3˝<br />

W<br />

BE1/BE4<br />

6.5˝<br />

W<br />

D<br />

Inside Corner<br />

6.5˝<br />

8.3˝<br />

8.3˝<br />

D<br />

7.25˝<br />

7.25˝<br />

10˝ to 17˝<br />

6˝ to cross<br />

bus center<br />

6˝ to cross<br />

bus center<br />

10˝ to 17˝<br />

10˝ to 17˝<br />

12˝ to 18˝<br />

15˝<br />

15˝<br />

12˝ to 18˝<br />

BE4<br />

Outside Corner<br />

12˝ to 18˝<br />

Outside Corner<br />

12˝ to 18˝<br />

Outside Corner<br />

12.06˝<br />

12.06˝<br />

12.06˝<br />

W<br />

6.5˝<br />

W<br />

7.25˝<br />

6˝ to cross<br />

bus center<br />

6˝ to cross<br />

bus center<br />

D<br />

Catalog<br />

number<br />

BE1 b<br />

BE4 b<br />

BE112 b<br />

BE412 b<br />

ELBT118<br />

ELBT318<br />

a Dimensions shown are representative of outside 8.3˝box dimensions<br />

10˝ WSP1/WSP3and do not include<br />

to 17˝<br />

allowances for mounting bumps, endwalls, SFT1/SPT3 covers, hubs, or hardware protrusions.<br />

Dimensions are subject to change.<br />

8.3˝<br />

10˝ to 17˝<br />

SFT1/SPT3<br />

W<br />

W<br />

6.5˝<br />

6.5˝<br />

W<br />

W<br />

7.25˝<br />

7.25˝<br />

D<br />

D<br />

WSP1/WSP3<br />

8.3˝<br />

10˝ to 17˝<br />

6˝ to cross<br />

SFT1/SPT3 bus center<br />

WSP1/WSP3<br />

WELB318<br />

WELB118<br />

WELB312<br />

WELB112<br />

WELB307E<br />

WELB107E<br />

WSP1<br />

WSP3<br />

SPT1<br />

SPT3<br />

Description<br />

Indoor Bussed Elbow, 15", 1-phase,<br />

3-wire, 1200 Amp maximum<br />

Indoor Bussed Elbow, 15", 3-phase,<br />

4-wire, 1200 Amp maximum<br />

Indoor Bussed Elbow,12”, 1-phase,<br />

3-wire, 1200 Amp maximum<br />

Indoor Bussed Elbow, 12”, 3-phase,<br />

4-wire, 1200 Amp maximum<br />

Indoor Bussed Elbow, Inside Corner,<br />

Expandable Range from 1"-18",<br />

1-phase, 3-wire, 1200 Amp max<br />

Indoor Bussed Elbow, Inside Corner,<br />

Expandable Range from 1"-18",<br />

3-phase, 4-wire, 1200 Amp max<br />

Outdoor Elbow, Inside corner,<br />

3-phase, 100k max AIC<br />

Outdoor Elbow, Inside corner,<br />

1–Phase, 100k max AIC<br />

Outdoor Elbow, Inside corner,<br />

3-phase, 100k max AIC<br />

Outdoor Elbow, Inside corner,<br />

1–Phase, 100k max AIC<br />

Outdoor Elbow, Outside corner,<br />

3-phase, 100k max AIC<br />

Outdoor Elbow, Outside corner,<br />

1–Phase, 100k max AIC<br />

Outdoor Bussed Extension,<br />

1-phase, 3-wire,<br />

1200 Amp maximum<br />

Outdoor Bussed Extension,<br />

3-phase, 4-wire,<br />

1200 Amp maximum<br />

Indoor Bussed Spacer, Expandable<br />

Range 10"-17", 1-phase, 3-wire,<br />

1200 Amp maximum<br />

Indoor Bussed Spacer, Expandable<br />

Range 10"-17", 3-phase, 4-wire,<br />

1200 Amp maximum<br />

b Do not connect indoor elbows directly to busway.<br />

Expandable elbow<br />

Dimensions (inches) a<br />

Height Width Depth<br />

5.62 15.06 4.87<br />

5.62 15.06 4.87<br />

5.62 12.09 4.87<br />

5.62 12.09 4.87<br />

30.8<br />

30.8<br />

Expandable<br />

12" - 18"<br />

Expandable<br />

12" - 18"<br />

7.8<br />

7.8<br />

30.06 18.31 7.97<br />

30.06 18.31 7.97<br />

30.06 12.31 7.97<br />

30.06 12.31 7.97<br />

30.06 6.80 7.97<br />

30.06 6.80 7.97<br />

12.06 6.50 7.25<br />

12.06 6.50 7.25<br />

30.8<br />

30.8<br />

Expandable<br />

10" - 17"<br />

Expandable<br />

10" - 17"<br />

8.3<br />

8.3<br />

3-104<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Uni-PAK<br />

Revised on 03/31/18<br />

Uni-PAK Metering: Introduction<br />

General Information<br />

Siemens Uni-PAK Metering offers maximum flexibility and ease<br />

of installation to meet the service requirements of multiple<br />

position metering projects. The outdoor/indoor devices are<br />

available in two through six gang set-ups which consist of a pull<br />

section with main lugs or stud terminations, and 4/5 jaw meter<br />

sockets with tenant circuit breaker provisions.<br />

Features include:<br />

n Siemens exclusive 200 ampere/position feature<br />

the QS breaker for faster / easier installation<br />

n Removable knock-out plate for back exit<br />

n Mounting rail for wall hanging - Siemens Exclusive<br />

n UL Listed for use with 60/75C degree wire<br />

n Outdoor/indoor construction<br />

n Overhead or underground service; load top,<br />

bottom or back<br />

3 METER<br />

CENTERS<br />

Standard Uni-Pak<br />

Quick Reference<br />

• ANSI - Standard #C 12.7-1987<br />

• NEMA - Standard #250-1985<br />

• UL - File #E27100<br />

• UL - Standard #50, 67,414<br />

• Voltage 240V AC Maximum<br />

• 125 amp or 200 amp Maximum<br />

per position<br />

• 1000 Amps maximum bus<br />

• 2-6 positions<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-105


Uni-PAK<br />

Revised on 03/31/18<br />

Uni-PAK Metering: Introduction<br />

Uni-PAK Construction<br />

3<br />

METER<br />

CENTERS<br />

Sturdy Steel Base Pan<br />

Provides reinforcing durable support<br />

for each tenant main breaker.<br />

2 Pole up to 225A @100kAIC<br />

Fits in 2 inch – compact width<br />

reduces enclosure size limiting<br />

total mounting space required.<br />

Handle<br />

available on larger devices to<br />

make lifting the unit easier.<br />

Top And Bottom Exit<br />

Line Lugs Factory<br />

Installed (WP, WEP,<br />

WPC)<br />

Rigid Molded Side Wall<br />

Provides reinforcing vertical<br />

support for each tenant main<br />

breaker.<br />

Main Breaker Retainer<br />

Ensures secure connection for<br />

breaker wiring.<br />

125 amp breakers can go into<br />

225 amp positions without<br />

conversion kits.<br />

Barrel Lock Capable Covers<br />

Accepts common utility barrel<br />

locks to protect against<br />

unauthorized usage.<br />

Lockable Breaker Cover<br />

1 Extra Neutral And Ground Termination<br />

3-106<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Uni-PAK<br />

Revised on 06/30/19<br />

Uni-PAK Metering: Introduction<br />

Uni-PAK Features and Benefits<br />

Mounting Rail<br />

Simplified mounting by using a<br />

separate rail to hang the device.<br />

(Please Note: a mounting rail is<br />

not applicable for two position<br />

125A WP and WEP devices)<br />

5Th Jaw Option<br />

Located in 6 or 9 o’clock<br />

position. Factory or field<br />

installed<br />

Horn Bypass Option<br />

Factory or field installed.<br />

Front Accessible Connections<br />

All connections use similar<br />

hardware and use belleville<br />

washers for tight connections.<br />

Ring Or Ringless Covers<br />

Individual ring or ringless type<br />

meter covers. Ring to ringless kits<br />

available to make last minute cover<br />

changes for specified utility<br />

requirements.<br />

Apartment No. Emboss<br />

Provides convenience and<br />

organization.<br />

More Features<br />

1) Large range of ampacities 200- 1000A<br />

2) 125 amp continuous duty sockets<br />

feed plug-in tenant breakers through<br />

125 Amps<br />

3) 200 amp continuous duty sockets<br />

feed plug-in tenant breakers through<br />

225 Amps<br />

4) UL Listed for short circuit ratings up to<br />

100,000 RMS symmetrical Amps at<br />

240V AC<br />

5) Lever Bypass models available<br />

6) EUSERC compliant models available<br />

7) 2 - 6 number of meter positions<br />

8) Outdoor/indoor construction<br />

9) Overhead or underground service;<br />

load top, bottom or back<br />

10) Compact design for ease of handling<br />

and installation<br />

11) All unmetered bus is barriered and<br />

sealable to prevent unauthorized<br />

access.<br />

12) Electrodeposited paint provides<br />

uniform coverage for long-lasting<br />

protection and sharp appearance<br />

13) Complies with the following industry<br />

standards<br />

-ANSI - Standard # C 12.7-1987<br />

-NEMA - Standard #250-1985<br />

-UL - File #E10703<br />

-UL - Standard#50, 67, 414<br />

3 METER<br />

CENTERS<br />

Removable Back End KO Plate<br />

Simplifies and speeds up pulling<br />

wire. Entire plate can be removed<br />

to allow ample space for wire.<br />

Knockouts in the plate can be<br />

removed before or after stack<br />

installation.<br />

Rain Channel<br />

Rotates out of the way for easy<br />

KO access<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-107


Uni-PAK<br />

Revised on 06/30/19<br />

Uni-PAK Metering: WP Ring Style<br />

Single Piece Tenant cover<br />

225 amp<br />

devices<br />

accept<br />

standard<br />

125 amp<br />

breakers<br />

Mounting<br />

Rail c<br />

Features<br />

n Individual split covers<br />

n Ring style meter construction<br />

n UL Listed for 60 / 75°C conductors. See equipment<br />

markings for applications<br />

n For small apartment buildings, small professional and<br />

commercial buildings<br />

n Completely self-contained meter centers<br />

n Two to six 125A and 225A sockets breaker positions<br />

3<br />

METER<br />

CENTERS<br />

Extra<br />

Neutral &<br />

Ground<br />

Provisions<br />

Factory<br />

Installed<br />

Lugs<br />

n Outdoor surface mounted enclosures<br />

n Compact, pre-bussed, easy to handle, hang and wire<br />

n Barriered, sealable compartment for unmetered currentcarrying<br />

parts<br />

n<br />

Al/Cu lay-in lugs, except two position 125A units<br />

n Top or bottom feed<br />

Removable KO Plate<br />

Smaller,<br />

more compact<br />

design<br />

enclosures<br />

are lighter<br />

and use<br />

less space<br />

n Bottom and rear branch wiring exits (Neutral and<br />

ground at bottom only)<br />

n ANSI #61 light gray electrodeposited paint on<br />

G90 galvanized steel<br />

n Field installable 5th jaw kit<br />

Ring Style Uni-PAK 120/240V 1 Phase, 3 Wire<br />

Maximum<br />

Tenant<br />

Main<br />

125<br />

225<br />

Bus<br />

Amperage<br />

Meter<br />

Positions<br />

Per Pak<br />

Catalog<br />

Number<br />

Breaker<br />

Provision<br />

Dimensions <br />

5th Jaw<br />

Assembly<br />

200 2 WP2211 c Max. AIC Height Width Depth<br />

Line Lugs Wire Range<br />

26.26 13.80 5.81<br />

#6-300 kcmil<br />

300 3 WP3311 38.75<br />

#2-600 kcmil<br />

25.42<br />

4 WP4411<br />

QP, QPH,<br />

47.75<br />

1/0-750 kcmil CU-AL or (2)<br />

400 5 WP4511 HQP, MP-T,<br />

65,000 38.75 38.95<br />

1/0-250 AL or (2) 1/0-3/0 CU<br />

6 WP4611 MP-HT,<br />

500 4 WP5411<br />

MP-MT<br />

47.75 26.47<br />

5 WP6511<br />

39.01<br />

(2) #2-600 kcmil<br />

600<br />

38.75<br />

6 WP6611 40.01<br />

ECMF5<br />

2 WP4212<br />

29.75<br />

7.56 6:00 or 9:00<br />

1/0-750 kcmil CU-AL or (2)<br />

400 3 WP4312 38.75 28.53<br />

1/0-250 AL or (2) 1/0-3/0 CU<br />

WP4412 QP, QPH,<br />

4<br />

HQP, MP-T,<br />

47.75<br />

WP6412 29.59<br />

MP-HT,<br />

600 5 WP6512<br />

100,000<br />

MP-MT, QS,<br />

(2) #2-600 kcmil<br />

46.22<br />

WP6612 QSH, QSHH,<br />

800 6 WP8612<br />

HQS, HQSH<br />

38.75<br />

(2) 1/0-750 kcmil or (4) 1/0-<br />

51.03<br />

250 AL or (4) 1/0-3/0 CU<br />

1000 WP10612 (3) #2-500 kcmil<br />

Uni-PAK Alternate Lug Kits (WP ONLY) b<br />

WPLK2400 400A Bus Lug Kit (2) #4-250<br />

WPLK2600 600A Bus Lug Kit (3) #6-250<br />

Replacement Factory Installed Lug Kits (WP & WEP Only)<br />

ECMLK3225<br />

300 KCMIL - For use in devices with 200A rated bus<br />

(contains 1 lug assembly)<br />

WPRLK600<br />

600 KCMIL - For use in devices with 300A, 500A, 600A or<br />

1000A rated bus (contains 1 lug assembly)<br />

WPRLK750<br />

750 KCMIL- For use in devices with 400A or 800A rated bus<br />

(contains 1 lug assembly)<br />

Dimensions shown are representative of outside box<br />

dimensions and do not include allowances for mounting<br />

bumps, endwalls, covers, hubs, or hardware protrusions.<br />

Dimensions are subject to change.<br />

b Designed for GA Power. Not limited thereto.<br />

c Mounting Rails are not applicable for two position 125A<br />

WP and WEP devices. These units are light enough to<br />

be mounted using the back wall mounting dimples.<br />

3-108<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Uni-PAK<br />

Revised on 06/30/19<br />

Uni-PAK Metering: WP Ringless Style, No Bypass<br />

Single Piece Tenant cover<br />

225 amp<br />

devices<br />

accept<br />

standard<br />

125 amp<br />

breakers<br />

Extra<br />

Neutral &<br />

Ground<br />

Provisions<br />

Removable KO Plate<br />

Mounting<br />

Rail c<br />

Factory<br />

Installed<br />

Lugs<br />

Smaller,<br />

more<br />

compact<br />

design<br />

enclosures<br />

are lighter<br />

and use<br />

less space<br />

Features<br />

n Ringless meter construction<br />

n Individual split covers with barrel lock compatibility<br />

n Available with horn bypass factory installed<br />

n UL Listed for 60/75°C conductors See equipment<br />

markings for applications<br />

n For small apartment buildings, small professional<br />

and commercial buildings<br />

n Completely self-contained meter centers<br />

n Two to six 125A and 225A breaker positions<br />

n Compact, pre-bussed, easy to handle, hang and wire<br />

n Barriered, sealable compartment for unmetered<br />

current-carrying parts<br />

n<br />

AI/Cu lay-in lugs, except two position 125A units<br />

n Top or bottom feed<br />

n Bottom and rear branch wiring exits (Neutral and<br />

ground at bottom only)<br />

n ANSI #61 light gray electrodeposited paint on<br />

G90 galvanized steel<br />

n 5th jaw kit included with each unit<br />

n Outdoor surface mounted enclosures<br />

3 METER<br />

CENTERS<br />

Ringless Style Uni-PAK 120/240V 1 Phase, 3 Wire<br />

Max.<br />

Tenant<br />

Main<br />

No Bypass<br />

125<br />

225<br />

Bus<br />

Amperage<br />

Meter<br />

Positions<br />

Per Pak<br />

Catalog<br />

Number<br />

Breaker<br />

Provision<br />

Max. AIC<br />

Dimensions <br />

Height Width Depth<br />

5th Jaw<br />

Assembly<br />

Horn<br />

Bypass<br />

Kit<br />

Line Lugs<br />

Wire Range<br />

200 2 WP2211RJ c 26.26 13.80 5.81<br />

#6-300 kcmil<br />

300 3 WP3311RJ 38.75<br />

#2-600 kcmil<br />

25.42<br />

4 WP4411RJ QP, QPH,<br />

47.75 1/0-750 kcmil CU-AL or<br />

400 5 WP4511RJ HQP, MP-T,<br />

(2) 1/0-250 AL or<br />

65,000<br />

MP-HT,<br />

38.75 38.95<br />

6 WP4611RJ<br />

(2) 1/0-3/0 CU<br />

MP-MT<br />

500 4 WP5411RJ 47.75 26.47<br />

600<br />

5 WP6511RJ<br />

39.01<br />

(2) #2-600 kcmil<br />

38.75<br />

6 WP6611RJ 40.01<br />

INCL.<br />

2 WP4212RJ<br />

29.75<br />

9:00<br />

ECMFH 1/0-750 kcmil CU-AL or<br />

7.56 factory<br />

400 3 WP4312RJ 38.75 28.53<br />

(2) 1/0-250 AL or<br />

6:00 field<br />

WP4412RJ QP, QPH,<br />

(2) 1/0-3/0 CU<br />

4<br />

HQP, MP-T,<br />

47.75<br />

WP6412RJ 29.59<br />

MP-HT,<br />

600 5 WP6512RJ<br />

MP-MT, 100,000<br />

(2) #2-600 kcmil<br />

46.22<br />

WP6612RJ QS, QSH,<br />

800 6 WP8612RJ<br />

QSHH,<br />

38.75<br />

(2) 1/0-750 kcmil or<br />

HQS, HQSH<br />

(4) 1/0-250 AL or<br />

51.03<br />

(4) 1/0-3/0 CU<br />

1000 WP10612RJ (3) #2-500 kcmil<br />

Uni-PAK Alternate Lug Kits (WP ONLY) b<br />

WPLK2400 400A Bus Lug Kit (2) #4-250<br />

WPLK2600 600A Bus Lug Kit (3) #6-250<br />

Replacement Factory Installed Lug Kits (WP & WEP Only)<br />

ECMLK3225<br />

300 KCMIL - For use in devices with 200A rated bus<br />

(contains 1 lug assembly)<br />

WPRLK600<br />

600 KCMIL - For use in devices with 300A, 500A, 600A or<br />

1000A rated bus (contains 1 lug assembly)<br />

WPRLK750<br />

750 KCMIL- For use in devices with 400A or 800A rated bus (contains<br />

1 lug assembly)<br />

Dimensions shown are representative of outside box<br />

dimensions and do not include allowances for mounting<br />

bumps, endwalls, covers, hubs, or hardware protrusions.<br />

Dimensions are subject to change.<br />

b Designed for GA Power. Not limited thereto.<br />

c Mounting Rails are not applicable for two position<br />

125 WP and WEP devices. These units are light enough<br />

to be mounted using the back wall mounting dimples.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-109


Uni-PAK<br />

Revised on 10/31/19<br />

Uni-PAK Metering: WP Ringless Style, Horn Bypass<br />

3<br />

METER<br />

CENTERS<br />

Single Piece Tenant cover<br />

225 amp<br />

devices<br />

accept<br />

standard<br />

125 amp<br />

breakers<br />

Extra<br />

Neutral &<br />

Ground<br />

Provisions<br />

Removable<br />

KO Plate<br />

Ringless Style Uni-PAK 120/240V 1 Phase, 3 Wire<br />

Max.<br />

Tenant<br />

Main<br />

Bus<br />

Amperage<br />

Horn Bypass<br />

125<br />

225<br />

Meter<br />

Positions<br />

Per Pak<br />

Mounting<br />

Rail d<br />

Factory<br />

Installed<br />

Lugs<br />

Smaller,<br />

more<br />

compact<br />

design<br />

enclosures<br />

are lighter<br />

and use<br />

less space<br />

Catalog<br />

Number Breaker Provision Max. AIC<br />

Features<br />

n Ringless meter construction<br />

n Individual split covers with barrel lock compatibility<br />

n Horn bypass factory installed<br />

n UL Listed for 60/75°C conductors See equipment<br />

markings for applications<br />

n For small apartment buildings, small professional and<br />

commercial buildings<br />

n Completely self-contained meter centers<br />

n Two to six 125A and 225A breaker positions<br />

n Barriered, sealable compartment for unmetered<br />

current-carrying parts<br />

n AI/Cu lay-in lugs, except two position 125A units<br />

n Top or bottom feed<br />

n Bottom and rear branch wiring exits (Neutral and<br />

ground at bottom only)<br />

n ANSI #61 light gray electrodeposited paint on<br />

G90 galvanized steel<br />

n 5th jaw kit included with each unit<br />

n Outdoor surface mounted enclosures<br />

Dimensions <br />

Height Width Depth<br />

5th Jaw<br />

Assembly<br />

Line Lugs<br />

Wire Range<br />

200 2 WP2211RJB d 26.26 13.80 5.81<br />

#6-300 kcmil<br />

300 3 WP3311RJB 38.75<br />

#2-600 kcmil<br />

25.42<br />

4 WP4411RJB 47.75 1/0-750 kcmil CU-AL or<br />

400 5 WP4511RJB QP, QPH, HQP, MP-T,<br />

(2) 1/0-250 AL or<br />

65,000 38.75 38.95<br />

6 WP4611RJB MP-HT, MP-MT<br />

(2) 1/0-3/0 CU<br />

500 4 WP5411RJB 47.75 26.47<br />

5 WP6511RJB<br />

(2) #2-600 kcmil<br />

600<br />

38.75 40.00<br />

6 WP6611RJB<br />

INCL.<br />

2 WP4212RJB<br />

29.75<br />

9:00 1/0-750 kcmil CU-AL or<br />

400 3 WP4312RJB 38.75 28.53 7.56<br />

factory (2) 1/0-250 AL or<br />

WP4412RJB<br />

6:00 field (2) 1/0-3/0 CU<br />

4<br />

QP, QPH, HQP, MP-T,<br />

47.75<br />

WP6412RJB 29.59<br />

600 5 WP6512RJB MP-HT, MP-MT, QS,<br />

100,000<br />

(2) #2-600 kcmil<br />

QSH, QSHH, HQS,<br />

46.22<br />

6 WP6612RJB<br />

HQSH<br />

38.75<br />

(2) 1/0-750 kcmil or (4) 1/0-<br />

800 6 WP8612RJB<br />

51.03<br />

250 AL or (4) 1/0-3/0 CU<br />

1000 6 WP10612RJB (3) #2-500 kcmil<br />

Horn Bypass, Alternate Enclosure Size and Lug Configuration c<br />

125 200 2 WPC2211RJB d QP, QPH, HQP, MP-T,<br />

65,000 32.53 13.80 5.81<br />

MP-HT, MP-MT<br />

INCL.<br />

#6-300 kcmil<br />

QP, QPH, HQP, MP-T,<br />

9:00<br />

225 400 2 WPC4212RJB<br />

100,000 29.75<br />

MP-HT, MP-MT, QS,<br />

factory<br />

28.53 7.56<br />

QSH, QSHH, HQS,<br />

6:00 field<br />

225 400 3 WPC4312RJB 100,000 38.75<br />

HQSH<br />

#6-350 kcmil<br />

Uni-PAK Alternate Lug Kits (WP ONLY) b<br />

WPLK2400 400A Bus Lug Kit (2) #4-250<br />

WPLK2600 600A Bus Lug Kit (3) #6-250<br />

Replacement Factory Installed Lug Kits (WP & WEP Only)<br />

ECMLK3225<br />

300 KCMIL - For use in devices with 200A rated bus<br />

(contains 1 lug assembly)<br />

WPRLK600<br />

600 KCMIL - For use in devices with 300A, 500A, 600A or<br />

1000A rated bus (contains 1 lug assembly)<br />

WPRLK750<br />

750 KCMIL- For use in devices with 400A or 800A rated bus<br />

(contains 1 lug assembly)<br />

Dimensions shown are representative of outside box<br />

dimensions and do not include allowances for mounting<br />

bumps, endwalls, covers, hubs, or hardware protrusions.<br />

Dimensions are subject to change.<br />

b Designed for GA Power. Not limited thereto.<br />

c Designed for use with Alliant Energy. Not limited thereto.<br />

d Mounting Rails are not applicable for two position 125A<br />

WP and WEP devices. These units are light enough to<br />

be mounted using the back wall mounting dimples.<br />

3-110<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Uni-PAK<br />

Revised on 06/30/19<br />

Uni-PAK Metering: WEP Ringstyle EUSERC<br />

225 amp<br />

devices<br />

accept<br />

standard<br />

125 amp<br />

breakers<br />

Single Piece<br />

Tenant cover<br />

Factory<br />

Installed Lugs<br />

Mounting<br />

Rail f<br />

Features<br />

n Individual split covers<br />

n UL Listed for 60 / 75°C conductors. See equipment<br />

markings for applications<br />

n Completely self-contained meter centers<br />

n Outdoor surface mounted enclosures<br />

n Semi flush with applicable field installed kit<br />

Extra<br />

Neutral &<br />

Ground<br />

Provisions<br />

n Barriered, sealable compartment for unmetered<br />

current-carrying parts<br />

n Al/Cu lay-in lugs, except two socket units<br />

n Top or bottom feed<br />

n Bottom and rear branch wiring exits (Neutral and<br />

ground at bottom only)<br />

n<br />

Meets EUSERC specifications when NEMA stud<br />

kit and flushing ring (if required) is field added.<br />

Compression lugs, if required, are sold separately.<br />

3 METER<br />

CENTERS<br />

Removable KO Plate<br />

EUSERC Compliant Ring Style Uni-PAK 120/240V 1 Phase, 3 Wire<br />

Max.<br />

Tenant<br />

Main<br />

125<br />

225<br />

Meter<br />

Positions<br />

Per Pak<br />

Catalog<br />

Number<br />

Breaker<br />

Provision<br />

Dimensions <br />

5th Jaw<br />

Assembly Line Lugs Wire Range<br />

Bus<br />

Amperage<br />

Semi-<br />

Flush<br />

Kit #<br />

EUSERC<br />

Drawing<br />

#342 <br />

Max. AIC Height Width Depth<br />

200 2 WEP2211 f 32.52 13.80<br />

#6-300 kcmil WPFK1 figure 1<br />

300 3 WEP3311 38.75<br />

#2-600 kcmil WPFK2<br />

25.42<br />

4 WEP4411 QP, QPH,<br />

47.75 1/0-750 kcmil CU-AL or WPFK3<br />

400<br />

(2) 1/0-250 AL or<br />

5 WEP4511<br />

HQP, MP-T,<br />

65,000 38.75 38.94<br />

(2) 1/0-3/0 CU<br />

MP-HT,<br />

figure 3<br />

500 4 WP5411<br />

MP-MT<br />

47.75 31.28<br />

WPFK4<br />

400 6 WEP4611<br />

(2) #2-600 kcmil<br />

5 WEP6511<br />

38.75 44.82<br />

600<br />

WPFK5<br />

6 WEP6611<br />

ECMF5<br />

2 WEP4212<br />

29.75<br />

7.56 6:00 or 1/0-750 kcmil CU-AL or WPFK6 figure 2<br />

400 3 WEP4312 38.75 28.53<br />

9:00 (2) 1/0-250 AL or<br />

WPFK7<br />

WEP4412 QP, QPH,<br />

(2) 1/0-3/0 CU<br />

WPFK8<br />

4<br />

HQP, MP-T,<br />

47.75<br />

WEP6412 34.41<br />

WPFK9 figure 3<br />

MP-HT,<br />

600 5 WEP6512<br />

(2) #2-600 kcmil<br />

MP-MT, 100,000<br />

WEP6612<br />

QS, QSH,<br />

QSHH,<br />

51.04 (2) 1/0-750 kcmil or WPFK10<br />

800<br />

38.75<br />

6 WEP8612 HQS, HQSH<br />

(4) 1/0-250 AL or<br />

(4) 1/0-3/0 CU<br />

N/A<br />

1000 WEP10612 57.53 (3) #2-500 kcmil WPFK11<br />

EUSERC Dual-amp Uni-PAK for EV Car Charger cd<br />

Max. Tenant<br />

Main<br />

Bus<br />

Amperage<br />

Meter<br />

Positions<br />

Per Pak<br />

Catalog<br />

Number Breaker Provision Max. AIC<br />

Position 1: 50A<br />

Position 2: 200A 200A 2 WEP2212EVf QP, QPH, HQP, QS, QSH,<br />

QSHH, HQS, HQSH<br />

Dimensions <br />

Height Width Depth<br />

5th Jaw<br />

Assembly Line Lugs Wire Range<br />

65,000 32.47 16.25 6.03 ECMF5 300 kcmil - #4 AWG<br />

NEMA Stud Kits (WEP Only) e<br />

Catalog Number Amperage Note<br />

WPSK400 400A fits 300-400<br />

WPSK600 600A fits 500-600<br />

WPSK800 800A —<br />

WPSK1000 1000A —<br />

Replacement Factory Installed Lug Kits (WP & WEP Only)<br />

ECMLK3225<br />

300 KCMIL - For use in devices with 200A rated bus<br />

(contains 1 lug assembly)<br />

WPRLK600<br />

600 KCMIL - For use in devices with 300A, 500A, 600A or<br />

1000A rated bus (contains 1 lug assembly)<br />

WPRLK750<br />

750 KCMIL- For use in devices with 400A or 800A rated bus (contains<br />

1 lug assembly)<br />

Dimensions shown are representative of outside box<br />

dimensions and do not include allowances for mounting<br />

bumps, endwalls, covers, hubs, or hardware protrusions.<br />

Dimensions are subject to change.<br />

Please note the EUSERC standard currently only covers up to<br />

600 amp devices. Please consult utility prior to installation.<br />

c Applies to EUSERC drawing #342.<br />

d Uni-PAK designed for EV car charger. Has separate meter for<br />

utility company to offer lower rate for power to EV charger<br />

(50A top position).<br />

e To be used with compression or mechanical lugs. Power<br />

Mod type LK_N2(E) lug kits can be used. View cutsheet for<br />

specific lug kit options.<br />

f Mounting Rails are not applicable for two position 125A<br />

WP and WEP devices nor the EV device. These units are<br />

light enough to be mounted using the back wall mounting<br />

dimples.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-111


Uni-PAK<br />

Revised on 03/31/19<br />

Uni-PAK Metering: WPL Ringless Style, Lever Bypass<br />

HQ Lever<br />

Bypass<br />

Mounting<br />

Rail<br />

Dual Hub Provisions<br />

Features:<br />

n Side mounted handles to help in lifting<br />

n Provisions for one, two, or three incoming<br />

conductors per have and neutral (lugs field installed)<br />

n 225 amp branch tenant provisions @ 100,000 AIC<br />

n Full line of 2-6 position devices<br />

n Light and compact design<br />

3<br />

METER<br />

CENTERS<br />

Factory<br />

installed<br />

5th Jaw<br />

125/225<br />

amp tenant<br />

provisions<br />

n Individual split cover<br />

n UL Listed for 60/75 degrees C conductors. See<br />

equipment markings for applications<br />

n For small apartment buildings, small professional<br />

and commercial buildings<br />

n Completely self-contained meter centers<br />

n Outdoor surface mounted enclosures<br />

Removable<br />

KO Plate<br />

n Barriered, sealable compartment for unmetered<br />

current-carrying parts<br />

n Top or bottom fed<br />

Dual barrel lock provisions<br />

2-4 position<br />

column construction<br />

Field installed<br />

lugs with 1,2,3<br />

conductor options<br />

n Bottom and rear branch wiring exits (Neutral and<br />

ground at bottom only)<br />

n ANSI #61 light gray electrodeposited paint on<br />

G90 galvanized steel.<br />

Ringless Style Uni-PAK 120/240V 1 Phase, 3 Wire, Lever Bypass<br />

Max.<br />

Tenant<br />

Main<br />

Bus<br />

Amperage<br />

Meter<br />

Positions<br />

Per Pak<br />

Catalog<br />

Number<br />

Breaker<br />

Provision<br />

Max. AIC<br />

Dimensions <br />

Height Width Depth<br />

5th Jaw<br />

Assembly<br />

Line Lugs Wire Range<br />

2 WPL4212RJ<br />

36.88<br />

225<br />

400<br />

600<br />

3 WPL4312RJ 49.88<br />

4<br />

WPL4412RJ<br />

WPL6412RJ<br />

5 WPL6512RJ<br />

WPL6612RJ<br />

800 6 WPL8612RJ<br />

1000 WPL10612RJ<br />

QP, QPH, HQP,<br />

MP-T, MP-HT,<br />

MP-MT, QS,<br />

QSH, QSHH,<br />

HQS, HQSH<br />

100,000<br />

62.88<br />

49.75<br />

33.72<br />

53.56<br />

57.81<br />

9.84<br />

INCL.<br />

9:00<br />

position<br />

3/8" Stud –<br />

Field installed lugs <br />

Lug Kits (WPL only) <br />

Catalog<br />

Number<br />

H56476<br />

H60162<br />

Wire<br />

Range<br />

3/0-800 kcmil<br />

(2) 1/0-250 kcmil OR<br />

(1) #4-600 kcmil<br />

H68752-1 (3) #6-250 kcmil<br />

H56732 (2) #4-350 kcmil<br />

H56732-M (2) #4-500 kcmil<br />

Dimensions shown are representative of outside box<br />

dimensions and do not include allowances for mounting<br />

bumps, endwalls, covers, hubs, or hardware protrusions.<br />

Dimensions are subject to change.<br />

Lug kits should be chosen based on the wire size being run to the unit.<br />

Wire should be sized according to the National Electrical Code. Lugs are<br />

sold separately. On 400-600A applications, a total of 3 lugs are required to<br />

wire the line side of the device. Lugs sold in packs of 2 pieces.<br />

3-112<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Uni-PAK<br />

Uni-PAK Metering: Dimensional and Knockout Diagrams<br />

WP2211<br />

Top view for<br />

WP2211 and WEP2211<br />

3 METER<br />

CENTERS<br />

Bottom view for<br />

WP2211 and WEP2211<br />

WEP2211<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-113


Uni-PAK<br />

Uni-PAK Metering: Dimensional and Knockout Diagrams<br />

WP3311<br />

WEP3311<br />

Top view for<br />

WP3311, WP4411, WEP3311 and WEP4411<br />

METER<br />

CENTERS<br />

3<br />

Bottom view for<br />

WP3311, WP4411, WEP3311 and WEP4411<br />

WP4411<br />

WEP4411<br />

3-114<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Uni-PAK<br />

Uni-PAK Metering: Dimensional and Knockout Diagrams<br />

WP5411<br />

Top view for<br />

WP5411<br />

Bottom view for<br />

WP5411<br />

3 METER<br />

CENTERS<br />

WEP5411<br />

Top view for<br />

WEP5411<br />

Bottom view for<br />

WEP5411<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-115


Uni-PAK<br />

Uni-PAK Metering: Dimensional and Knockout Diagrams<br />

WP4511<br />

WEP4511<br />

METER<br />

CENTERS<br />

3<br />

Bottom view for<br />

WP4511, WP4611, WEP4511 and WEP4611<br />

Top view for<br />

WP4511, WP4611, WEP4511 and WEP4611<br />

WP4611<br />

WEP4611<br />

3-116<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Uni-PAK<br />

Uni-PAK Metering: Dimensional and Knockout Diagrams<br />

WP6511<br />

3 METER<br />

CENTERS<br />

Top view for WP6511 and WP6611<br />

Bottom view for<br />

WP6511 and WP6611<br />

WP6611<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-117


Uni-PAK<br />

Uni-PAK Metering: Dimensional and Knockout Diagrams<br />

WEP6511<br />

METER<br />

CENTERS<br />

3<br />

Top view for WEP6511 and WEP6611<br />

Bottom view for<br />

WEP6511 and WEP6611<br />

WEP6611<br />

3-118<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Uni-PAK<br />

Uni-PAK Metering: Dimensional and Knockout Diagrams<br />

WP4212<br />

WEP4212<br />

Top view for<br />

WP4212, WEP4212, WP4312 and WEP4312<br />

3 METER<br />

CENTERS<br />

Bottom view for<br />

WP4212, WEP4212, WP4312 and WEP4312<br />

WP4312<br />

WEP4312<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-119


Uni-PAK<br />

Uni-PAK Metering: Dimensional and Knockout Diagrams<br />

WP4412<br />

WEP4412<br />

Top view for<br />

WP4412 and WEP4412<br />

3<br />

METER<br />

CENTERS<br />

Bottom view for<br />

WP4412 and WEP4412<br />

WP6412<br />

Top view for<br />

WP6412<br />

Bottom view for<br />

WP6412<br />

3-120<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Uni-PAK<br />

Uni-PAK Metering: Dimensional and Knockout Diagrams<br />

WEP6412<br />

Top view for<br />

WEP6412<br />

Bottom view for<br />

WEP6412<br />

3 METER<br />

CENTERS<br />

WP8612<br />

WEP8612<br />

Top view for<br />

WP8612 and WEP8612<br />

Bottom view for<br />

WP8612 and WEP8612<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-121


Uni-PAK<br />

Uni-PAK Metering: Dimensional and Knockout Diagrams<br />

WP6512<br />

METER<br />

CENTERS<br />

3<br />

Top view for WP6512 and WP6612<br />

Bottom view for<br />

WP6512 and WP6612<br />

WP6612<br />

3-122<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Uni-PAK<br />

Uni-PAK Metering: Dimensional and Knockout Diagrams<br />

WEP6512<br />

3 METER<br />

CENTERS<br />

Top view for WEP6512 and WEP6612<br />

Bottom view for<br />

WEP6512 and WEP6612<br />

WEP6612<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-123


Uni-PAK<br />

Uni-PAK Metering: Dimensional and Knockout Diagrams<br />

WP10612 / WEP10612<br />

Top view for WP10612<br />

Bottom view for WP10612<br />

METER<br />

CENTERS<br />

3<br />

WEP2212EV<br />

Top view<br />

Bottom view<br />

WPL4212<br />

Top view for WPL4212<br />

Bottom view for WPL4212<br />

3-124<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Uni-PAK<br />

Uni-PAK Metering: Dimensional and Knockout Diagrams<br />

WPL4312<br />

Top view for<br />

WPL4312 and WPL4412<br />

3 METER<br />

CENTERS<br />

Bottom view for<br />

WPL4312 and WPL4412<br />

WPL4412<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-125


Uni-PAK<br />

Uni-PAK Metering: Dimensional and Knockout Diagrams<br />

WPL6512<br />

Top view for<br />

WPL6512 and WPL6612<br />

METER<br />

CENTERS<br />

3<br />

Bottom view for<br />

WPL6512 and WPL6612<br />

WPL6612<br />

3-126<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Uni-PAK<br />

Uni-PAK Metering: Dimensional and Knockout Diagrams<br />

WPL8612<br />

WPL10612<br />

3 METER<br />

CENTERS<br />

Top view for<br />

WPL8612 and WPL10612<br />

Bottom view for<br />

WPL8612 and WPL10612<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-127


Power Mod and Uni-PAK<br />

Revised on 06/30/19<br />

Multifamily Metering Accessories and Replacement Parts<br />

3<br />

METER<br />

CENTERS<br />

Lugs, breakers and other accessories<br />

Siemens offers a wide range of accessories to help your product fit the application.<br />

Eliminate the need for special orders with replacement part kits available for your<br />

convenience. All kits come with appropriate hardware and instruction sheets for installation.<br />

3-128<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 10/31/19<br />

Lug Kits: Lug selector<br />

Lugs are factory installed on WB main breaker modules<br />

200A-1200A. Alternate lug kit options (including 750kcmil)<br />

are available.<br />

A field installable compression lug landing pad is available<br />

as an accessory for standard breaker module 250A-1200A.<br />

Compression lug kits must be ordered in addition to the lug<br />

landing pad accessory. The lug landing pad accessory is not<br />

compatible with WB skinny mains (200-1200A WB's with B,<br />

BU, T or TU suffixes).<br />

Lug kits must be ordered separately for standard breaker<br />

modules 1400A-2000A.<br />

All EUSERC breaker mains, standard switches, EUSERC<br />

switches, standard tap boxes, and EUSERC tap boxes require<br />

lugs to be ordered separately and field installed.<br />

EUSERC Breaker Main Types WEB and WEBM<br />

Standard Breaker Main Types WB and WBM<br />

4 500 kcmil LK14500 ab LK34500 ab<br />

(Do not use this table for Skinny Mains)<br />

No. Wires Max Wire 1 Phase<br />

3 Phase<br />

No. Wires Max Wire 1 Phase<br />

3 Phase<br />

Amperage per Phase Size lug kit<br />

lug kit<br />

Amperage per Phase Size lug kit<br />

lug kit<br />

200-400 1 750 kcmil LK11750N2 LK31750N2<br />

200-400 1 750 kcmil LK11750 a LK31750 a<br />

2 500 kcmil LK12500N2 LK32500N2<br />

2 500 kcmil LK12500 ab LK32500 ab<br />

500-600 2 500 kcmil LK12500N2E LK32500N2E<br />

450-600 2 500 kcmil LK12500 ab LK32500 ab<br />

2 750 kcmil LK12750N2 LK32750N2<br />

700-800 3 500 kcmil LK13500 ab LK33500 ab<br />

3 750 kcmil LK13750N2 LK33750N2<br />

3 750 kcmil LK13750 a LK33750 a<br />

4 500 kcmil LK14500N2 LK34500N2<br />

900-1200 3 750 kcmil LK13750 a LK33750 a<br />

700-800 2 600 kcmil LK12600N2 LK32600N2<br />

4 500 kcmil LK14500 ab LK34500 ab<br />

2 750 kcmil LK12750N2 LK32750N2<br />

1400-1600 5 600 kcmil LK15600N2 LK35600N2<br />

3 500 kcmil LK13500N2 LK33500N2<br />

5 750 kcmil LK15750N2 LK35750N2<br />

3 750 kcmil LK13750N2 LK33750N2<br />

6 750 kcmil LK16750N2 LK36750N2<br />

3 750 kcmil LK13750N2E LK33750N2E<br />

1800-2000 6 750 kcmil LK16750N2 LK36750N2<br />

4 500 kcmil LK14500N2 LK34500N2<br />

4 500 kcmil LK14500N2E LK34500N2E<br />

Standard Breaker Main with Lug Landing Pad Installed c<br />

5 600 kcmil LK15600N2 LK35600N2<br />

Types WB and WBM<br />

900-1200 3 750 kcmil LK13750N2E LK33750N2E<br />

Amperage<br />

No. Wires Max Wire 1 Phase<br />

3 Phase<br />

4 500 kcmil LK14500N2E LK34500N2E<br />

per Phase Size lug kit<br />

lug kit<br />

5 600 kcmil LK15600N2 LK35600N2<br />

200-400 1 600 kcmil LK11600N2 LK31600N2<br />

2 350 kcmil LK12350N2 LK32350N2 Feed-Thru Tap Box with Breaker Type WBT<br />

450-600 2 350 kcmil LK12350N2 LK32350N2<br />

No. Wires Max Wire<br />

3 Phase<br />

700-800 2 600 kcmil LK12600N2 LK32600N2<br />

Amperage per Phase Size<br />

lug kit<br />

2 750 kcmil LK12750N2 LK32750N2<br />

1200 3 750 kcmil LK33750N2<br />

3 500 kcmil LK13500N2 LK33500N2<br />

4 500 kcmil LK34500N2<br />

3 750 kcmil LK13750N2 LK33750N2<br />

2400 6 750 kcmil LK36750N2<br />

4 500 kcmil LK14500N2 LK34500N2<br />

8 500 kcmil LK38500N2C<br />

900-1200 3 750 kcmil LK13750N2 LK33750N2<br />

8 750 kcmil LK38750N2A<br />

4 500 kcmil LK14500N2 LK34500N2<br />

Feed-Thru Breaker Main Types BFT and BFTM<br />

Skinny Breaker Main Types WB and WBM<br />

(Skinny Mains are 200-1200A WB/WBM units, with B, BU, T, or TU suffixes) Amperage<br />

No. Wires<br />

per Phase<br />

Max Wire<br />

Size<br />

1 Phase<br />

lug kit<br />

3 Phase<br />

lug kit<br />

Amperage<br />

No. Wires<br />

per Phase<br />

Max Wire<br />

Size<br />

1 Phase<br />

lug kit<br />

3 Phase<br />

lug kit<br />

200-400 1 750 kcmil LK11750 a LK31750 a<br />

2 500 kcmil LK12500 ab LK32500 ab<br />

450-600 2 500 kcmil LK12500 ab LK32500 ab<br />

700-800 3 500 kcmil LK13500 ab LK33500 ab<br />

3 750 kcmil LK13750 a LK33750 a<br />

4 500 kcmil LK14500 a LK34500 a<br />

900-1200 3 750 kcmil LK13750 a LK33750 a<br />

Definition of suffixes:<br />

(no N2) = square sentron breaker type lugs<br />

N2(E) = Nema 2-stud lug mounting pattern<br />

N2C =<br />

Same as N2 except designed for use with copper wire.<br />

Includes upward bus extension kit.<br />

N2A =<br />

Same as N2 except designed for use with aluminum wire.<br />

Includes upward bus extension kit.<br />

N2CD=<br />

Same as N2C except includes downward bus extension kit<br />

instead of upward extension.<br />

N2AD=<br />

Same as N2A except includes downward bus extension kit<br />

instead of upward extension.<br />

1200 3 750 kcmil LK13750N2 LK33750N2<br />

4 500 kcmil LK14500N2 LK34500N2<br />

5 600 kcmil LK15600N2 LK35600N2<br />

5 750 kcmil LK15750N2 LK35750N2<br />

6 750 kcmil LK16750N2 LK36750N2<br />

8 500 kcmil LK18500N2CD LK38500N2CD<br />

8 750 kcmil LK18750N2AD LK38750N2AD<br />

1400-1600 5 600 kcmil LK15600N2 LK35600N2<br />

5 750 kcmil LK15750N2 LK35750N2<br />

6 750 kcmil LK16750N2 LK36750N2<br />

8 500 kcmil LK18500N2CD LK38500N2CD<br />

8 750 kcmil LK18750N2AD LK38750N2AD<br />

1800-2000 6 750 kcmil LK16750N2 LK36750N2<br />

8 500 kcmil LK18500N2CD LK38500N2CD<br />

8 750 kcmil LK18750N2AD LK38750N2AD<br />

a Lug kits - Sentron mechanical breaker lugs<br />

b Factory installed lugs<br />

c Lug landing pad must be ordered in addition to lug kit.<br />

Refer to 3-132 for lug landing pad options.<br />

d WT tap boxes require 2 lug kits when used on feed thru applications.<br />

3 METER<br />

CENTERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-129


Power Mod<br />

Revised on 06/30/19<br />

Lug Kits: Lug selector<br />

LLP1200<br />

1200A Lug<br />

landing pad<br />

Note that while some connector kits may physically fit, the<br />

maximum wire range of the connector may not meet UL<br />

required bending space. If a lug kit other than what is on the<br />

wiring diagram is used, it is up to the installer to ensure the<br />

installation is acceptable.<br />

3<br />

METER<br />

CENTERS<br />

Standard Switch Main Type WS<br />

Amperage<br />

No. Wires<br />

per Phase<br />

Max Wire<br />

Size<br />

1 Phase<br />

lug kit<br />

3 Phase<br />

lug kit<br />

400 1 600 kcmil LK11600N2 LK31600N2<br />

2 500 kcmil LK12500N2 LK32500N2<br />

2 500 kcmil LK12500N2E LK32500N2E<br />

2 750 kcmil LK12750N2 LK32750N2<br />

600 2 500 kcmil LK12500N2 LK32500N2<br />

2 500 kcmil LK12500N2E LK32500N2E<br />

800 2 600 kcmil LK12600N2 LK32600N2<br />

2 750 kcmil LK12750N2 LK32750N2<br />

3 500 kcmil LK13500N2 LK33500N2<br />

1200 4 500 kcmil LK14500 ab LK34500 ab<br />

EUSERC Tap Box Type WET<br />

Amperage<br />

No. Wires<br />

per Phase<br />

Max Wire<br />

Size<br />

1 Phase<br />

lug kit<br />

3 Phase<br />

lug kit<br />

400 1 750 kcmil LK11750N2 LK31750N2<br />

2 500 kcmil LK12500N2 LK32500N2<br />

800 2 600 kcmil LK12600N2 LK32600N2<br />

2 750 kcmil LK12750N2 LK32750N2<br />

3 500 kcmil LK13500N2 LK33500N2<br />

3 750 kcmil LK13750N2 LK33750N2<br />

4 500 kcmil LK14500N2 LK34500N2<br />

1200 3 750 kcmil LK13750N2E LK33750N2E<br />

4 500 kcmil LK14500N2E LK34500N2E<br />

5 600 kcmil LK15600N2 LK35600N2<br />

EUSERC Switch Main Type WES<br />

Amperage<br />

No. Wires<br />

per Phase<br />

Max Wire<br />

Size<br />

1 Phase<br />

lug kit<br />

3 Phase<br />

lug kit<br />

400 1 750 kcmil LK11750N2 LK31750N2<br />

2 500 kcmil LK12500N2 LK32500N2<br />

600 2 500 kcmil LK12500N2 LK32500N2<br />

2 750 kcmil LK12750N2 LK32750N2<br />

3 750 kcmil LK13750N2 LK33750N2<br />

4 500 kcmil LK14500N2 LK34500N2<br />

800 2 600 kcmil LK12600N2 LK32600N2<br />

2 750 kcmil LK12750N2 LK32750N2<br />

3 500 kcmil LK13500N2 LK33500N2<br />

3 750 kcmil LK13750N2 LK33750N2<br />

4 500 kcmil LK14500N2 LK34500N2<br />

1200 3 750 kcmil LK13750N2E LK33750N2E<br />

4 500 kcmil LK14500N2E LK34500N2E<br />

5 600 kcmil LK15600N2 LK35600N2<br />

Standard Tap Box Type WTB<br />

Amperage<br />

No. Wires<br />

per Phase<br />

Max Wire<br />

Size<br />

1 Phase<br />

lug kit<br />

3 Phase<br />

lug kit<br />

400 1 600 kcmil LK11600N2 LK31600N2<br />

1 750 kcmil LK11750N2 LK31750N2<br />

2 500 kcmil LK12500N2 LK32500N2<br />

800 2 600 kcmil LK12600N2 LK32600N2<br />

2 750 kcmil LK12750N2 LK32750N2<br />

3 500 kcmil LK13500N2 LK33500N2<br />

1200 3 750 kcmil LK13750N2 LK33750N2<br />

4 500 kcmil LK14500N2 LK34500N2<br />

1600 5 600 kcmil LK15600N2 LK35600N2<br />

5 750 kcmil LK15750N2 LK35750N2<br />

6 750 kcmil LK16750N2 LK36750N2<br />

2000 6 750 kcmil LK16750N2 LK36750N2<br />

8 500 kcmil LK18500N2C LK38500N2C<br />

8 750 kcmil LK18750N2A LK38750N2A<br />

2400 6 750 kcmil LK16750N2 LK36750N2<br />

8 500 kcmil LK18500N2C LK38500N2C<br />

8 750 kcmil LK18750N2A LK38750N2A<br />

a Lug kits - Sentron mechanical breaker lugs<br />

b Factory installed lugs<br />

c Lug landing pad must be ordered in addition to lug kit.<br />

Refer to 3-132 for lug landing pad options.<br />

d WT tap boxes require 2 lug kits when used on feed thru applications.<br />

Feed-Thru Tap Box Type WT_PU d<br />

Amperage<br />

No. Wires<br />

per Phase<br />

Max Wire<br />

Size<br />

1 Phase<br />

lug kit<br />

3 Phase<br />

lug kit<br />

400 1 750 kcmil LK11750N2 LK31750N2<br />

2 500 kcmil LK12500N2 LK32500N2<br />

800 2 600 kcmil LK12600N2 LK32600N2<br />

2 750 kcmil LK12750N2 LK32750N2<br />

3 500 kcmil LK13500N2 LK33500N2<br />

4 500 kcmil LK14500N2 LK34500N2<br />

1200 3 750 kcmil LK13750N2 LK33750N2<br />

4 500 kcmil LK14500N2E LK34500N2E<br />

5 600 kcmil LK15600N2 LK35600N2<br />

1600 5 600 kcmil LK15600N2 LK35600N2<br />

5 750 kcmil LK15750N2 LK35750N2<br />

6 750 kcmil LK16750N2 LK36750N2<br />

8 500 kcmil LK18500N2C LK38500N2C<br />

8 750 kcmil LK18750N2A LK38750N2A<br />

2000 6 750 kcmil LK16750N2 LK36750N2<br />

8 500 kcmil LK18500N2C LK38500N2C<br />

8 750 kcmil LK18750N2A LK38750N2A<br />

2400 6 750 kcmil LK16750N2 LK36750N2<br />

8 500 kcmil LK18500N2C LK38500N2C<br />

8 750 kcmil LK18750N2A LK38750N2A<br />

ConEd Tap Box Type WTBN<br />

Amperage<br />

No. Wires<br />

per Phase<br />

Max Wire<br />

Size<br />

1 Phase<br />

lug kit<br />

400 1 600 kcmil LK31600N2<br />

1 750 kcmil LK31750N2<br />

2 350 kcmil LK32350N2<br />

2 500 kcmil LK32500N2<br />

600 2 350 kcmil LK32350N2<br />

2 500 kcmil LK32500N2<br />

800 2 600 kcmil LK32600N2<br />

2 750 kcmil LK32750N2<br />

3 500 kcmil LK33500N2<br />

4 500 kcmil LK34500N2<br />

1200 3 750 kcmil LK33750N2<br />

4 500 kcmil LK34500N2<br />

3-130<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 10/31/19<br />

Modular Metering Lug Kits<br />

Power Mod: Modular Metering Lug Kits<br />

Lug Kits<br />

Quick Reference<br />

n UL 486 A/B<br />

n Tin-plated aluminium<br />

n NEMA 2-stud lug<br />

mounting pattern<br />

Lug Kit Contents<br />

Wire Range:<br />

1/0-750 kcmil<br />

Wire Range:<br />

#6-350 kcmil<br />

Wire Range:<br />

#2-600 kcmil<br />

Wire Range:<br />

300-800 kcmil<br />

Upward Bus<br />

Extension<br />

Downward Bus<br />

Extension<br />

Wire Binding<br />

Screw Torque:<br />

500 lb.-in.<br />

Wire Binding<br />

Screw Torque:<br />

275 lb.-in.<br />

Wire Binding<br />

Screw Torque:<br />

500 lb.-in.<br />

Wire Binding<br />

Screw Torque:<br />

500 lb.-in.<br />

Wire Binding<br />

Screw Torque:<br />

500 lb.-in.<br />

Wire Binding<br />

Screw Torque:<br />

500 lb.-in.<br />

Lug Kit<br />

Catalog<br />

Number Wire Range Lug Quantity Lug Quantity Lug Quantity Lug Quantity Unit Quantity Unit Quantity<br />

LK12350N2 #6-350 kcmil 3<br />

LK32350N2 #6-350 kcmil 4<br />

LK12500N2 1/0-500 kcmil 3<br />

LK32500N2 1/0-500 kcmil 4<br />

LK12500N2E #2-500 kcmil 6<br />

LK32500N2E #2-500 kcmil 8<br />

LK13500N2 1/0-500 kcmil 3 3<br />

LK33500N2 1/0-500 kcmil 4 4<br />

LK14500N2 1/0-500 kcmil 6<br />

LK34500N2 1/0-500 kcmil 8<br />

LK14500N2E 1/0-500 kcmil 3 6<br />

LK34500N2E 1/0-500 kcmil 4 8<br />

LK15600N2 1/0-600 kcmil 6 3<br />

LK35600N2 1/0-600 kcmil 8 4<br />

LK11600N2 #2-600 kcmil 3<br />

LK31600N2 #2-600 kcmil 4<br />

LK12600N2 #2-600 kcmil 6<br />

LK32600N2 #2-600 kcmil 8<br />

LK11750N2 300-750 kcmil 3<br />

LK31750N2 300-750 kcmil 4<br />

LK12750N2 300-750 kcmil 6<br />

LK32750N2 300-750 kcmil 8<br />

LK13750N2 300-750 kcmil 3 3<br />

LK33750N2 300-750 kcmil 4 4<br />

LK13750N2E 300-750 kcmil 9<br />

LK33750N2E 300-750 kcmil 12<br />

LK15750N2 300-750 kcmil 6 3<br />

LK35750N2 300-750 kcmil 8 4<br />

LK16750N2 1/0-750 kcmil 9<br />

LK36750N2 1/0-750 kcmil 12<br />

LK18500N2C 1/0-500 kcmil CU 12 3<br />

LK38500N2C 1/0-500 kcmil CU 16 4<br />

LK18570N2A 1/0-750 kcmil AL 12 3<br />

LK38570N2A 1/0-750 kcmil AL 16 4<br />

LK18500N2CD 1/0-500 kcmil CU 12 3<br />

LK38500N2CD 1/0-500 kcmil CU 16 4<br />

LK18570N2AD 1/0-750 kcmil AL 12 3<br />

LK38570N2AD 1/0-750 kcmil AL 16 4<br />

3 METER<br />

CENTERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-131


Power Mod and Uni-PAK<br />

Revised on 10/31/19<br />

Multifamily Metering Accessories and Replacement Parts<br />

Conduit Hubs<br />

Catalog Number<br />

Description<br />

Type HD<br />

Type RX<br />

EC56854 b<br />

2" Conduit Hub<br />

EC38594<br />

3/4" Conduit Hub<br />

EC56855 b<br />

2 1/2" Conduit Hub<br />

EC38596<br />

1" Conduit Hub<br />

EC56856<br />

3" Conduit Hub<br />

EC38597<br />

1 1/4" Conduit Hub<br />

EC56857<br />

3 1/2" Conduit Hub<br />

EC38598<br />

1 1/2" Conduit Hub<br />

EC56858<br />

4" Conduit Hub<br />

EC9747-1113<br />

Adapter plate for HD/RX<br />

EC56933S<br />

Closure Plate<br />

Accessory Catalog number Description<br />

3<br />

METER<br />

CENTERS<br />

QC1<br />

QuickConnect 1-phase, 3-wire, 1200 Amp maximum.<br />

QC4<br />

QuickConnect 3-phase, 4-wire, 1200 Amp maximum.<br />

LLP600 e<br />

Lug Landing Pad for 200-600 Amp Standard Breaker modules (WB) only. Allows for use<br />

of compression lugs or NEMA 2-stud type lugs. Not compatible with Skinny mains.<br />

LLP1200 e<br />

Lug Landing Pad for 800-1200 Amp Standard Breaker modules (WB) only. Allows for use<br />

of compression lugs or NEMA 2-stud type lugs. Not compatible with Skinny mains.<br />

WMMBK a<br />

Pass-thru bushing - for use with pull box WMMB modules.<br />

WMEP<br />

Plastic end enclosure plate to cover exposed horizontal bussing at the ends<br />

of the meter center lineup. Comes factory included with all mains and tapboxes.<br />

This kit comes with (1) plate, (1) gasket and (4) screws.<br />

SRSS<br />

Sealing ring - snap-on, stainless steel.<br />

SRSW<br />

Sealing ring - screw type, stainless steel.<br />

SRSTD<br />

Sealing ring - snap on, aluminum (comes standard).<br />

ECJS c<br />

Meter bypass jumper 4 AND 5 JAW. For temporary use ONLY. Only works with ECPP cover.<br />

200A max. Comes with 2 jumpers. Not for use with WML sockets over 200A. Not compatible<br />

with utility anti-inversion clips.<br />

ECPP<br />

Plastic Ring Style cover plate. May be used with ringless style cover in conjunction with ECJS.<br />

As of 4/10/2019 this bushing is no longer supplied with<br />

WMMB devices. If needed it must be ordered separately.<br />

b Item is a kit consisting of adapter plate and<br />

RX Type Hub<br />

c Required per 1-phase meter socket. Residential type ring<br />

and ringless - 200 Amp max. Meter cannot be installed<br />

while in use. Made for use with ECPP cover plate.<br />

d No kits are available for WEP2211.<br />

e Cannot be used for top-feed applications.<br />

3-132<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod and Uni-PAK<br />

Revised on 10/31/19<br />

Multifamily Metering Accessories and Replacement Parts<br />

Accessory Catalog number Description<br />

ECCP3<br />

Plastic Ringless Style cover plate.<br />

ECMMRS<br />

ECMFTAB<br />

Power Mod mini ratchet set Includes:<br />

n 2” T-25 Torx Bit - Eases removal and re-installing of cover screws<br />

n 5/16" Magnetic Nut Setter - Eases the installation of tap boxes when QuickBolt assembly<br />

is required to be removed from one side. In addition, could be used to quickly install or<br />

reposition the 5th jaw.<br />

n 3/8” x 1/4” drive deep well socket - Eases connection of adjacent module using<br />

hardware provided.<br />

Mounting tabs or "ears" for top of Power Mod devices. Comes with 2 tabs.<br />

3 METER<br />

CENTERS<br />

ECMFGN125<br />

Kit for replacement or additional ground and neutral lugs for 100-125 Amp (W)MM,<br />

(W)MN, (W)ML and (W)MLZ(F) stacks. Can also be used as the replacement or additional<br />

ground lug kit for 225 Amp (W)MM, (W)MN, (W)MT and (W)ML stacks.<br />

ECMFN225<br />

Neutral lug kit for 225 Amp stacks (type (W)MM, (W)MN, (W)MT and (W)ML stacks only).<br />

ECMFPK<br />

Power Mod loose parts replacement kit. Includes: instruction sheet, (6) apartment number<br />

labels, (6) service disconnect labels, (4) 1/4-20 hex nuts, (4) #10-32 hex nuts, (4) 1/4-20 x 1/2<br />

screws, (4) wingnuts, (4) #10 flat washers, (4) #10 lock washers.<br />

ECMFCS<br />

Cover screw replacement (quantity 10) for Power Mod and Uni-PAK devices.<br />

ECMMBC<br />

Power Mod breaker cover replacement Type 3. Used only on 1200A WES mains,<br />

all WMK stacks, 100A 3-ph in/3-ph out (W)ML stacks and 400A (W)ML non-fused stacks.<br />

ECMMBCM<br />

Power Mod replacement plastic breaker cover for type all current 200-1000A WB, WXB, WEB<br />

and WBT main breaker units. This is also the replacement cover for all 1200A-2000A main<br />

breaker devices manufactured prior to 4/16/2018. [Please note that WB skinny mains and WBT<br />

mains manufactured between the dates of 4/16/2018 and 6/14/2019 in the 900-1000Amp range<br />

temporarily used the ECMMBCL cover. After 6/14/2019 these 900-1000A WB skinny and WBT<br />

mains transitioned to use ECMMBCM.] This cover is also used for 225A 3-phase (W)ML stacks.<br />

ECBC<br />

Breaker cover replacement for type (W)MM, (W)ML, WMT single phase meter stacks<br />

and series WP, WEP, WPL, and WPC Uni-PAK.<br />

ECMMBCL<br />

Power Mod replacement plastic breaker cover for all 1200-2000A main breaker modules<br />

manufactured on or after 4/16/2018 (WB, WXB, WEB, WBT and BFT). [Please note that WB<br />

skinny mains and WBT mains manufactured between the dates of 4/16/2018 and 6/14/2019<br />

in the 900-1000Amp range used this ECMMBCL cover as well.]<br />

ECMMKOP<br />

Power Mod knock-out plate with knock-outs for type (W)MM Residential Stacks<br />

(not suitable for Uni-PAK). Attaches to back wall of unit.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-133


Power Mod and Uni-PAK<br />

Revised on 10/31/19<br />

Multifamily Metering Accessories and Replacement Parts<br />

Accessory Catalog number Description<br />

ECMMNKOP<br />

Power Mod knock-out plate without knock-outs for Type (W)MM Residential Stacks<br />

(not suitable for Uni-Pak). This is a blank plate, ideal for contractors who want to cut<br />

their own holes in the back plate.<br />

ECMLNKOP<br />

Blank removable back plate for 100A (3-phase) and 225A (W)ML stacks as well as all<br />

1-phase-out (W)MT stacks. (not suitable for Uni-PAK).<br />

3<br />

METER<br />

CENTERS<br />

ECMFWLCLIP<br />

MMCLIP<br />

Replacement rail/clip located on back of unit with wheels (Power Mod only).<br />

Replacement rail/clip that comes on back of unit, no wheels<br />

(for Power Mod modules manufactured prior to 2009).<br />

MMRAIL<br />

MMZR24<br />

MMZR36<br />

MMZR48<br />

MMZR60<br />

12” Standard wall mounting rail (Power Mod or Uni-PAK).<br />

24" long mounting "Z" rail for wall mounting (Power Mod or Uni-PAK).<br />

36" long mounting "Z" rail for wall mounting (Power Mod or Uni-PAK).<br />

48" long mounting "Z" rail for wall mounting (Power Mod or Uni-PAK).<br />

60" long mounting "Z" rail for wall mounting (Power Mod or Uni-PAK).<br />

ECMFH<br />

Horn bypass kit for field replacement or addition on ringless type<br />

(W)MM meter stacks and ringless series WP and WPC Uni-PAK.<br />

ECMF5<br />

ECMT5<br />

5th jaw replacement for Power Mod type (W)MM meter stacks and<br />

series WP, WEP, and WPC Uni-PAK.<br />

5th jaw Power Mod stack WMT. 1-ph in/1-ph out only.<br />

ECMF5i<br />

Isolated 5th jaw. Allows for 5th jaw to be disconnected from the neutral while in place.<br />

For use on (W)MM and (W)MN stacks only.<br />

ECMFS<br />

Meter socket replacement for Power Mod type (W)MM meter stacks and<br />

series WP, WEP, and WPC Uni-PAK.<br />

ECMFBM1<br />

ECMFBM2<br />

Breaker mounting replacement for 125 Amp Power Mod type (W)MM, (W)ML,<br />

WMT single phase meter stacks and series WP, WEP, WPL and WPC Uni-PAK.<br />

Breaker mounting replacement for 225 Amp Power Mod type (W)MM, (W)ML,<br />

WMT single phase meter stacks and series WP, WEP, WPL and WPC Uni-PAK.<br />

ECMFMC<br />

Ringtype meter cover replacement for Power Mod type (W)MM Ringstyle residential<br />

meter stacks and WP, WEP, and WPC series ringstyle Uni-PAK.<br />

Do not confuse this kit with the Conversion kit. If going from ringless to ring type cover,<br />

a conversion kit is required, not a replacement kit.<br />

ECMFMCR<br />

Ringless meter cover replacement for Power Mod type (W)MM ringless<br />

residential meter stacks and WP and WPC series ringless Uni-PAK.<br />

Do not confuse this kit with the Conversion kit. If going from ring to ringless type cover,<br />

a conversion kit is required, not a replacement kit.<br />

3-134<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod and Uni-PAK<br />

Revised on 10/31/19<br />

Multifamily Metering Accessories and Replacement Parts<br />

Accessory Catalog number Description<br />

ECMMRLCK<br />

Power Mod and Uni-PAK ring to ringless cover conversion kit for<br />

type (W)MM meter stacks and WP series Uni-PAK.<br />

ECMMRCK<br />

Power Mod and Uni-PAK ringless to ring cover conversion kit for<br />

type (W)MM meter stacks and WP series Uni-PAK.<br />

ECMFC<br />

Bottom pull cover. Blank cover below the socket positions.<br />

For (W)MM Power Mod and WP, WEP, and WPC Uni-PAK.<br />

3 METER<br />

CENTERS<br />

ECMFPS<br />

Quick phase "Z" strap replacement for Power Mod type (W)MM meter stacks<br />

and series WP, WEP, and WPC Uni-PAK.<br />

ECWMLPS<br />

Phase Straps for Lever bypass stacks. For use on 3-PH-In/1-PH-out, 125A, (W)ML stacks<br />

only. Only applicable to field phaseable units. Includes (2) line straps, (2) phase straps and<br />

(6) 1/4-20 hex nuts.<br />

ECMMFSP400<br />

400A Power Mod metering switch main fuse bus replacement kit. Includes:<br />

bus plates, screws, hex nuts, washers and bolts (used to mount fuse in the module).<br />

For use with WS, WES and WXS switches.<br />

ECMMFSP600<br />

600A Power Mod metering switch main fuse bus replacement kit. Includes:<br />

bus plates, screws, hex nuts, washers and bolts (used to mount fuse in the module).<br />

For use with WS, WES and WXS switches.<br />

ECMMFSP800<br />

800A Power Mod metering switch main fuse bus replacement kit. Includes:<br />

bus plates, screws, hex nuts, washers and bolts (used to mount fuse in the module).<br />

For use with WS, WES and WXS switches.<br />

ECAFL<br />

(10) Arc flash labels.<br />

ECMMQRSCR<br />

Power Mod QR and QJ 3-phase breaker mounting and strap screws. Kit contains (2) #10-32<br />

x 2-7/16" screws and (3) 1/4-20 x 5/8" screws. For use on (W)ML and WMT Power Mod.<br />

ECMMGBE<br />

Power Mod ground lug bar assembly kit. Can be used on the following modules:<br />

WT_PU (1600-2400A), WTB (2000-2400A), WBT324X_(all), BFT (all). Adds 4 rows of<br />

NEMA stud kits to the ground bar. Can be used in bottom or top position. Includes<br />

1 extension assembly and screws. In feed-through devices, a second kit may be<br />

required for the outgoing grounds as well.<br />

ECGLK3300<br />

300 kcmil ground lug extension kit. Includes (3) lugs for ground. May be used on WB<br />

(up to 1200A), WBT, WTB and WT_PU (1600-2400A).<br />

ECGLK6300<br />

300 kcmil ground lug extension kit. Includes (6) lugs for ground. May be used on WB<br />

(up to 1200A), WBT, WTB, WET and WT_PU (400-2400A). Included bonding strap is only<br />

necessary for the WB series.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-135


Power Mod and Uni-PAK<br />

Revised on 06/30/19<br />

Multifamily Metering Accessories and Replacement Parts<br />

Accessory Catalog number Description<br />

ECMFMC10<br />

Ring-type meter cover for (W)MN stacks only.<br />

ECWML10<br />

Replacement ringless meter socket cover for use on 125A (W)ML, (W)MLZ<br />

and (W)MLZF stacks that are single-phase out only.<br />

3<br />

ECWMLC<br />

Bottom pull cover. Replacement part only. Only to be used on 125A (W)ML.<br />

METER<br />

CENTERS<br />

ECWMLZEP<br />

Secondary cross bus side cover plate. Replacement part only. For use on fusible meter<br />

stacks (W)MLZ(F).<br />

ECWMLZBP<br />

Bottom removable endwall plate for (W)MLZ(F) stacks. Replacement part only.<br />

ECWMLZFBUS<br />

Secondary cross bus assembly for (W)MLZ(F) stacks. These 3 bus bars are installed toward<br />

the base of the (W)MLZ stack to create a secondary bus connection to an adjacent (W)MLZF<br />

or (W)MLZ stack. Includes (3) bus bars and (6) hex nuts. Replacement part only.<br />

Replacement Breaker Covers<br />

These replacement metal covers (breaker side) are for WML, WMT and other three-phase modules manufactured prior to<br />

February 5, 2016. Prior to this date, these stacks were made to be only compatible with the QJ breaker. The QR breaker<br />

replaced the QJ breaker, so for these modules to be compatible with the QR breaker they will need a cover conversion kit from<br />

the table below. Stacks manufactured after February 5, 2016 will accept both QJ and QR breakers without needing a cover kit.<br />

Accessory Catalog Number Description<br />

ECWML3BC1 RX breaker side metal door cover for WML13225RJ accepts QR and QJ breaker.<br />

ECWML3BC2 RX breaker side metal door cover for WML23225RJ accepts QR and QJ breaker.<br />

ECWML3BC3 RX breaker side metal door cover for WML33225RJ accepts QR and QJ breaker.<br />

ECWML3BC4 RX breaker side metal door cover for WML43225RJ accepts QR and QJ breaker.<br />

ECML3BC1<br />

RX breaker side metal door cover for ML13225RJ accepts QR and QJ breaker.<br />

ECML3BC2<br />

RX breaker side metal door cover for ML23225RJ accepts QR and QJ breaker.<br />

ECML3BC3<br />

RX breaker side metal door cover for ML33225RJ accepts QR and QJ breaker.<br />

ECML3BC4<br />

RX breaker side metal door cover for ML43225RJ accepts QR and QJ breaker.<br />

ECW3MMUBC1 RX breaker side metal door cover for W3MM1200U accepts QR and QJ breaker.<br />

ECW3MMUBC2 RX breaker side metal door cover for W3MM2200U accepts QR and QJ breaker.<br />

ECW3MMUBC3 RX breaker side metal door cover for W3MM3200U accepts QR and QJ breaker.<br />

ECW3MMUBC4 RX breaker side metal door cover for W3MM4200U accepts QR and QJ breaker.<br />

ECW3MMBC1 RX breaker side metal door cover for W3MM1200 accepts QR and QJ breaker.<br />

ECW3MMBC2 RX breaker side metal door cover for W3MM2200 accepts QR and QJ breaker.<br />

ECW3MMBC3 RX breaker side metal door cover for W3MM3200 accepts QR and QJ breaker.<br />

ECW3MMBC4 RX breaker side metal door cover for W3MM4200 accepts QR and QJ breaker.<br />

ECWMT3BC1 RX breaker side metal door cover for WMT13225J accepts QR and QJ breaker.<br />

ECWMT3BC2 RX breaker side metal door cover for WMT23225J accepts QR and QJ breaker.<br />

ECWMT3BC3 RX breaker side metal door cover for WMT33225J accepts QR and QJ breaker.<br />

ECMT3BC1<br />

RX breaker side metal door cover for MT13225J accepts QR and QJ breaker.<br />

ECMT3BC2<br />

RX breaker side metal door cover for MT23225J accepts QR and QJ breaker.<br />

ECMT3BC3<br />

RX breaker side metal door cover for MT33225J accepts QR and QJ breaker.<br />

ECW3USSBC1 RX breaker side metal door cover for W3MM1225USS accepts QR and QJ breaker.<br />

ECW3USSBC2 RX breaker side metal door cover for W3MM2225USS accepts QR and QJ breaker.<br />

ECW3USSBC3 RX breaker side metal door cover for W3MM3225USS accepts QR and QJ breaker.<br />

3-136<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod and Uni-PAK<br />

Revised on 06/30/19<br />

Tenant Circuit Breakers<br />

QS2100 QR23B225 Q260 Q360<br />

10K AIC 22K AIC 42K AIC 65K AIC 100K AIC<br />

Amperage Type QP Type QPH — Type HQP Type HQPH<br />

For use in 125 Amp and 225 a Amp single phase output WMM, WML, WMT, WP, WPC, WEP, WPL metering c<br />

60 Q260 Q260H Q260HH Q260HH —<br />

70 Q270 Q270H Q270HH Q270HH —<br />

80 Q280 Q280H Q280HH Q280HH —<br />

90 Q290 Q290H Q290HH Q290HH —<br />

100 Q2100 Q2100H Q2100HH Q2100HH HQ2100H<br />

110 Q2110 Q2110H Q2110HH Q2110HH —<br />

125 Q2125 Q2125H Q2125HH Q2125HH HQ2125H<br />

For use in 100 Amp, 3- phase output WML meter stacks only<br />

60 Q360 Q360H Q360HH Q360HH —<br />

70 Q370 Q370H Q370HH Q370HH —<br />

80 Q380 Q380H Q380HH Q380HH —<br />

90 Q390 Q390H Q390HH Q390HH —<br />

100 Q3100 Q3100H Q3100HH Q3100HH —<br />

For use in 225 a Amp single phase output WMM, WML, WMT, WP, WPC, WEP, WPL metering c<br />

Type QS b Type QSH b Type QSHH Type HQS b Type HQSH b<br />

100 QS2100 QS2100H QSH2100 QS2100HH HQS2100H<br />

125 QS2125 QS2125H QSH2125 QS2125HH HQS2125H<br />

150 QS2150 QS2150H QSH2150 QS2150HH HQS2150H<br />

175 QS2175 QS2175H QSH2175 QS2175HH HQS2175H<br />

200 QS2200 QS2200H QSH2200 QS2200HH HQS2200H<br />

225 QS2225 QS2225H QSH2225 QS2225HH HQS2225H<br />

3 METER<br />

CENTERS<br />

For use in 225 Amp 3-phase output WML and WMT meter stacks only<br />

10K AIC 25K AIC 65K AIC 100K AIC<br />

Amperage Type QR2 Type QRH2 Type HQR2 Type HQR2H<br />

100 QR23B100 QRH23B100 HQR23B100 HQR23B100H<br />

125 QR23B125 QRH23B125 HQR23B125 HQR23B125H<br />

150 QR23B150 QRH23B150 HQR23B150 HQR23B150H<br />

175 QR23B175 QRH23B175 HQR23B175 HQR23B175H<br />

200 QR23B200 QRH23B200 HQR23B200 HQR23B200H<br />

225 QR23B225 QRH23B225 HQR23B225 HQR23B225H<br />

a QP Breakers will fit in 225A WMM, WML, and WMT<br />

meter stacks.<br />

b QS series rates with Murray circuit breakers.<br />

c Breaker selection (when applied to Uni-PAK) applies<br />

to WP, WPC, WEP, WPL, Uni-PAK metering only. QS<br />

breakers will not nit in SP or MP series.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-137


Power Mod and Uni-PAK<br />

Revised on 06/30/19<br />

Tenant Circuit Breakers<br />

QS Breaker <br />

Power Mod's core offering of residential Meter Stacks, type WMM, offers the widest<br />

product offering and flexibility in the industry. Each meter stack houses the<br />

QuickSystem features to maximize productivity and minimize labor costs. To<br />

further simplify installation, our 225 Amp meter stacks feature the QS breaker.<br />

The QS breaker adds to the Siemens exclusive feature set in our Power Mod<br />

product line. Benefits and part numbers include:<br />

Front View<br />

3<br />

METER<br />

CENTERS<br />

▪ An exclusive side wired design saves wiring space and eliminates<br />

difficult "S bends"<br />

▪ No need for costly filler plates — QS 225 Amp breaker takes the<br />

same space as standard 100 Amp QPs<br />

▪ Single right hand bend wiring - saves time and wire<br />

▪ Provides 100K AIC flexibility from 100 up to 225 Amps<br />

▪ 10K to 100K AIC Series Rating<br />

QS Breaker a<br />

Breaker Type QS QSH QSHH HQS HQSH<br />

Amperage 10K AIC 22K AIC 42K AIC 65K AIC 100K AIC<br />

100 QS2100 QS2100H QSH2100 QS2100HH HQS2100H<br />

110 QS2110 QS2110H QSH2110 QS2110HH HQS2110H<br />

125 QS2125 QS2125H QSH2125 QS2125HH HQS2125H<br />

150 QS2150 QS2150H QSH2150 QS2150HH HQS2150H<br />

175 QS2175 QS2175H QSH2175 QS2175HH HQS2175H<br />

200 QS2200 QS2200H QSH2200 QS2200HH HQS2200H<br />

225 QS2225 QS2225H QSH2225 QS2225HH HQS2225H<br />

QS Breaker Dimension Drawing<br />

1.00<br />

.19<br />

.58<br />

.96<br />

1.38<br />

CAUTION<br />

PRECAUCION<br />

7.89<br />

4.31<br />

000A<br />

000000<br />

ON<br />

20<br />

2.22<br />

NEUTRAL<br />

.99<br />

OFF<br />

20<br />

.19<br />

1.39<br />

1.34<br />

.28<br />

.16<br />

2.01<br />

2.38<br />

2.56<br />

2.66<br />

.37<br />

2.12<br />

1.06<br />

1.16<br />

QS breakers are not compatible with 125A rated stacks<br />

and also not compatible with PAK devices with 125A<br />

max tenant main ratings.<br />

3-138<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Uni-PAK Metering<br />

Accessories<br />

Revised on 10/31/19<br />

Selection<br />

Uni-PAK Lug Kits<br />

ECHS125 WPFKx<br />

WPRLK600 WPRLK750<br />

Catalog<br />

Number Description<br />

Replacement Factory Installed Lug Kits<br />

(WP & WEP Only)<br />

ECMLK3225<br />

300 KCMIL - For use in devices with 200A<br />

rated bus (contains 1 lug assembly)<br />

600 KCMIL - For use in devices with 300A,<br />

WPRLK600 500A, 600A or 1000A rated bus (contains<br />

1 lug assembly)<br />

WPRLK750<br />

750 KCMIL- For use in devices with 400A or<br />

800A rated bus (contains 1 lug assembly)<br />

Uni-PAK Alternate Lug Kits (WP ONLY)<br />

WPLK2400 400A Bus Lug Kit (2) #4-250<br />

WPLK2600 600A Bus Lug Kit (3) #6-250<br />

Uni-PAK NEMA Stud Kits (WEP ONLY) f<br />

WPSK400 Fits 300 - 400A<br />

WPSK600 Fits 500 - 600A<br />

WPSK800 800A<br />

WPSK1000 1000A<br />

Lug Kits (WPL ONLY) <br />

H56476 3/0-800 kcmil<br />

H60162 (2) 1/0-250 kcmil OR (1) #4-600 kcmil<br />

H68752-1 (3) #6-250 kcmil<br />

H56732 (2) #4-350 kcmil<br />

H56732-M (2) #4-500 kcmil<br />

Uni-PAK Accessories<br />

Catalog<br />

Number Description<br />

Type “HD” Conduit Hubs<br />

EC56854 2” Conduit Hub d<br />

EC56855 2½" Conduit Hub d<br />

EC56856 3" Conduit Hub<br />

EC56857 3½" Conduit Hub<br />

EC56858 4" Conduit Hub<br />

EC56933S Closure Plate<br />

Type “RX” Conduit Hubs<br />

EC38594 ¾" Conduit Hub<br />

EC38596 1" Conduit Hub<br />

EC38597 1¼" Conduit Hub<br />

EC38598 1½" Conduit Hub<br />

EC38599 2" Conduit Hub<br />

EC38600 2½" Conduit Hub<br />

EC38595 Closure Plate<br />

EC9747-1113 Adapter plate for HD/RX c<br />

Cover Plate<br />

ECPP<br />

ECCP3<br />

Plastic Ring Style a<br />

Plastic Ringless Style<br />

3 METER<br />

CENTERS<br />

Semi-flush Mounting Kits (WEP only)<br />

Flange Kit<br />

Number<br />

WPFK1<br />

WPFK2<br />

WPFK3<br />

WPFK4<br />

WPFK5<br />

WPFK6<br />

WPFK7<br />

WPFK8<br />

WPFK9<br />

WPFK10<br />

WPFK11<br />

WPFK12<br />

WPFK13<br />

Designed for use with:<br />

WEP2211, WTEG2211<br />

WEP3311, WTEG2211<br />

WEP4411, WTEG4411<br />

WEP4511, WTEG4511, WEP4611, WTEG4611<br />

WEP6511, WTEG6511, WEP6611, WTEG6611<br />

WEP4212, WTEG4212<br />

WEP4312, WTEG4312<br />

WEP4412, WTEG4412<br />

WEP6412, WTEG6412<br />

WEP6512, WTEG6512, WEP6612, WTEG6612<br />

WEP10612, WTEG10612<br />

WEP5411, WTEG5411<br />

WEP8612, WTEG8612<br />

a Not for use on lever bypass units.<br />

b Order NSK600 and PLK600 kits for use with 800<br />

Amp PAK. CU Cable only approved with 800A<br />

device.<br />

c Use Adapter plate with RX hubs for PAK units.<br />

d These items made of Adapter plate and<br />

equivalent RX hub.<br />

Lug kits should be chosen based on the wire<br />

size being run to the unit. Wire should be sized<br />

according to the National Electrical Code. Lugs<br />

are sold separately. On 400-600A applications, a<br />

total of 3 lugs are required to wire the line side<br />

of the device. Lugs sold in packs of 2 pieces.<br />

f To be used with compression or mechanical<br />

lugs. Power Mod type LK_N2(E) lug kits can be<br />

used. View cutsheet for specific lug kit options.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-139


Meter Centers<br />

OBSOLETE Modular Metering Replacement Parts Kits<br />

Revised on 10/31/19<br />

Selection<br />

MMBMT<br />

MMSCK1<br />

MMCVR1<br />

3<br />

METER<br />

CENTERS<br />

Part Number Description Contents<br />

Breaker Covers<br />

GMBC1 <br />

One Top and bottom black plastic breaker<br />

Group Metering Breaker Cover - 125Amp Positions<br />

cover piece, 1 gasket, and a locking clip<br />

GMBC2 <br />

Top and bottom black plastic breaker<br />

Group Metering Breaker Cover - 200Amp Positions<br />

cover pieces, gasket, and locking clip<br />

Meter Covers<br />

MMCVR1 <br />

1 Ringstyle meter cover welded with<br />

Modular Metering Covers 125A Ring Style<br />

support brackets and painted<br />

MMCVR1R <br />

1 Ringless style meter cover welded with<br />

Modular Metering Covers 125A Ringless<br />

support brackets and painted<br />

MMCVR2 <br />

1 Ringstyle meter cover welded with<br />

Modular Metering Covers 200A Ring Style<br />

support brackets and painted<br />

MMCVR2R <br />

1 Ringless style meter cover welded with<br />

Modular Metering Covers 200A Ringless<br />

support brackets and painted<br />

MMCVRLOW Modular Metering Bottom Cover<br />

Smallest (bottom) cover on meter stack<br />

(neutral access cover)<br />

and screw included<br />

MMCVRSCR Modular Metering Cover Screws Bag of 10 screws<br />

PAKMCVRR <br />

1 Ringstyle meter cover welded with<br />

Tenant cover for Ring Style Uni-Pak Meter Center<br />

support brackets and painted<br />

PAKMCVRL <br />

1 Ringless style meter cover welded with<br />

Tenant cover for RingLess Uni-Pak Meter Center<br />

support brackets and painted<br />

Meter Socket/Breaker Mounting<br />

MMBMT1 Modular Metering Breaker Mounting S/A 125A Breaker mounting assembly for 125A stacks<br />

MMBMT2 Modular Metering Breaker Mounting S/A 200A Breaker mounting assembly for 200A stacks<br />

MMSCK1 Modular Metering Meter Socket Assembly 125A Meter Socket assembly includes jaws,<br />

MMSCK2 Modular Metering Meter Socket Assembly 200A straps, and hardware – see picture above<br />

MMSRPK c<br />

Replacement parts for 125A pre-1991<br />

modular metering (see tip below)<br />

Brief history of residential Power Mod products<br />

Meter and breaker mounting assembly.<br />

Contains 1 red plastic meter base, 4 jaws and<br />

connecting line straps for the breaker mount.<br />

Loose Parts Kits <br />

MMPK11 Modular Metering Loose Parts Kit 125A 1 PHASE<br />

MMPK13 Modular Metering Loose Parts Kit 125A 3 PHASE All loose screw bags, labels, instruction<br />

MMPK21 Modular Metering Loose Parts Kit 200A 1 PHASE sheet and aluminum sealing ring (No SBJ)<br />

MMPK23 Modular Metering Loose Parts Kit 200A 3 PHASE<br />

Miscellaneous Replacement Parts<br />

ECMM5J 5th Jaw Kit Contains 1 fifth jaw assembly, enough for one meter socket<br />

ECHBK Horn Bypass Kit Contains 4 horn bypsasses, enough for one meter socket<br />

ECCP3U ad<br />

Used beneath breaker cover to fill in the gaps on the sides of a 2-pole<br />

4" to 2" Filler Plate<br />

breaker used in a 4-inch slot<br />

1st Generation<br />

Modular Metering c<br />

2nd Generation<br />

Modular Metering a<br />

Power Mod<br />

(current)<br />

GMBC2<br />

a Fits modular metering made from 1992-<br />

2009 and PAK devices from 1992-2003<br />

(ie. 2nd Generation).<br />

Fits PAK devices from 2004-2011<br />

Fits 125A modular metering and<br />

PAK made from 1980-1991 only. Not<br />

compatible with EUSERC style PAK<br />

(EUSERC versions contain suffix W/WF).<br />

No other replacement parts available<br />

(ie. 1st Generation).<br />

d Not for use on lever bypass units.<br />

Stacks prior to<br />

1992 have the<br />

breaker under the<br />

meter socket.<br />

From 1992 to 2009, the<br />

breakers are located<br />

on the right side of the<br />

meter socket.<br />

Since 2009, the<br />

breakers are now located<br />

on the left side of<br />

the meter socket.<br />

3-140<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 06/30/19<br />

WMM Residential Meter Stacks Rating Charts<br />

Use the tables below to determine the correct combination of equipment and circuit breakers for the available fault current.<br />

This chart provides series rating information for the most common applications. For a complete series rating chart please contact<br />

your local sales office.<br />

Available fault current<br />

RMS symmetrical amps at<br />

Meter module<br />

120/240 volts maximum Main Modules a branch circuit breakers<br />

Load center<br />

branch circuit breakers<br />

to 10,000<br />

Series<br />

WB, WB_U, WBM, WBM_U<br />

WEB, WEB_U, WEBM, WEBM_U<br />

WS_U, WES_U, WTB_U,<br />

WET_U, WXB, WXB_U<br />

WXBM, WXBM_U, WBTM,<br />

WBTM_U, BFTM and BFTM_U<br />

Series<br />

WB, WB_U, WBM, WBM_U<br />

WEB, WEB_U, WEBM, WEBM_U<br />

WXB, WXB_U, WXBM,<br />

WXBM_U, WBTM, WBTM_U,<br />

BFTM and BFTM_U<br />

QP, QPH, HQP, HQPH (2 pole, 15–125A)<br />

QS, QSH, QSHH, HQS, HQSH<br />

(2 pole, 100–225A)<br />

QPH, HQP, HQPH (2 pole, 15–125A)<br />

QS, QSH, QSHH, HQS, HQSH<br />

(2 pole, 100–225A)<br />

QP, QPH, HQP, QT, QAF, QAFH,<br />

QPF, QPHF, QE, QEH<br />

3 METER<br />

CENTERS<br />

to 22,000<br />

Series<br />

WS_U, WES_U<br />

WXS<br />

QPH, HQP, HQPH (2 pole, 15–125A)<br />

QS, QSH, QSHH, HQS, HQSH<br />

(2 pole, 100–225A)<br />

QP, QPH, HQP, QT, QAF, QAFH,<br />

QPF, QPHF, QE, QEH<br />

Series<br />

WTB_U, WET_U<br />

QPH, HQP, HQPH (2 pole, 15–125A)<br />

QSH, QSHH, HQS, HQSH<br />

(2 pole, 100–225A)<br />

to 42,000<br />

Series<br />

WB, WB_U, WBM, WBM_U<br />

WEB, WEB_U, WEBM, WEBM_U<br />

WXB, WXB_U, WXBM,<br />

WXBM_U, WBTM, WBTM_U,<br />

BFTM and BFTM_U<br />

Series<br />

WS_U, WES_U<br />

WXS<br />

QPH, HQP, HQPH (2 pole, 15–125A)<br />

QS, QSH, QSHH, HQS, HQSH<br />

(2 pole, 100–225A)<br />

QPH, HQP, HQPH (2 pole, 15–125A)<br />

QS, QSH, QSHH, HQS, HQSH<br />

(2 pole, 100–225A)<br />

QP, QPH, HQP, QT, QAF, QAFH,<br />

QPF, QPHF, QE, QEH<br />

Series<br />

WTB_U, WET_U<br />

HQP, HQPH (2 pole, 15–125A)<br />

QSHH, HQS, HQSH (2 pole, 100–225A)<br />

Series<br />

WB, WB_U, WBM, WBM_U<br />

WEB, WEB_U, WEBM, WEBM_U<br />

WXB, WXB_U<br />

QPH, HQP, HQPH (2 pole, 15–125A)<br />

QS, QSH, QSHH, HQS, HQSH<br />

(2 pole, 100–225A)<br />

to 65,000<br />

Series<br />

WS_U, WES_U<br />

WXS<br />

QPH, HQP, HQPH (2 pole, 15–125A)<br />

QS, QSH, QSHH, HQS, HQSH<br />

(2 pole, 100–225A)<br />

QP, QPH, HQP, QT, QAF, QAFH,<br />

QPF, QPHF, QE, QEH<br />

Series<br />

WTB_U, WET_U<br />

HQP, HQPH (2 pole, 15–125A)<br />

HQS, HQSH (100–225A)<br />

to 100,000<br />

Series<br />

WB_U, WBM_U, WEB_U,<br />

WEBM_U, WS_U, WES_U,<br />

WXB_U, WXS, WXBM_U,<br />

WBTM_U and BFTM_U<br />

HQPH (2 pole, 100–125A)<br />

QS, QSH, QSHH, HQS, HQSH<br />

(2 pole, 100–225A)<br />

QP, QPH, HQP, QT, QAF, QAFH,<br />

QPF, QPHF, QE, QEH<br />

Series<br />

WTB_U, WET_U<br />

HQPH (2 pole, 100–125A)<br />

HQSH (100–225A)<br />

a Service Entrance Modules:<br />

WB, WEB, WXB, WBT and BFT have 65k AIC breakers factory installed [(JXD2-A, JXD6-A) (LXD6-A) (MXD6) (NXD6) (PXD6) (RXD6)]<br />

WB_U, WEB_U, WXB_U, WBT_U and BFT_U have 100k AIC breakers factory installed [(HJXD6-A) (HLXD6-A) (HMXD6) (HNXD6) (HPXD6) (HRXD6)]<br />

WBM, WEBM, WXBM, WBTM and BFTM have 65k AIC DAS breakers factory installed [(SND6) (SPD6)]<br />

WBM_U, WEBM_U, WXBM_U, WBTM_U and BFTM_U have 100k AIC DAS breakers factory installed [(SHND6) (SHPD6)]<br />

WS_U and WES_U are fused switches (Class T – 300 volt)<br />

WTB_U and WET_U have NO overcurrent protection<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-141


Power Mod<br />

Revised on 06/30/19<br />

WML and WMT Commercial Meter Stacks Rating Charts<br />

Use the tables below to determine the correct combination of equipment and circuit breakers for the available fault current.<br />

This chart provides series rating information for the most common applications. For a complete series rating chart please contact<br />

your local sales office.<br />

3<br />

METER<br />

CENTERS<br />

Available fault current<br />

RMS symmetrical amps at<br />

120/240V max 1-phase, 240V<br />

max 3-Phase Main Modules a Meter module<br />

branch circuit breakers<br />

to 10,000<br />

to 22,000<br />

Series<br />

WB, WB_U, WBM, WBM_U<br />

WEB, WEB_U, WEBM, WEBM_U<br />

WS_U, WES_U, WTB_U,<br />

WET_U, WXB, WXB_U, WXS,<br />

WXBM, WXBM_U, WBTM,<br />

WBTM_U, BFTM and BFTM_U<br />

Series<br />

WB, WB_U, WBM, WBM_U<br />

WEB, WEB_U, WEBM,<br />

WEBM_U, WXB, WXB_U,<br />

WXBM, WXBM_U, WBTM,<br />

WBTM_U, BFTM and BFTM_U<br />

Series<br />

WS_U, WES_U<br />

WXS<br />

Series<br />

WTB_U<br />

WET_U<br />

QP, QPH, HQP, HQPH (2 pole,15–125A)<br />

QS, QSH, QSHH, HQS, HQSH<br />

(2 pole,100-225A)<br />

QP, QPH, HQP (3 pole,15–100A)<br />

QR2, QRH2, HQR2, HQR2H (3 Pole, 100–225A)<br />

JXD2-A, JD6-A, JXD6-A (2 and 3 pole, 200–400A)<br />

LD6-A, LXD6-A (2 and 3 pole, 600A)<br />

QPH, HQP, HQPH (2 pole,15–125A)<br />

QS, QSH, QSHH, HQS, HQSH (2 pole,100–225A)<br />

QPH, HQP (3 pole,15–100A)<br />

QR2, QRH2, HQR2, HQR2H (3 Pole, 100–225A)<br />

QPH, HQP, HQPH (2 pole,15–125A)<br />

QS, QSH, QSHH, HQS, HQSH (2 pole,100–225A)<br />

QPH, HQP (3 pole,15–100A)<br />

QR2, QRH2, HQR2, HQR2H (3 Pole, 100–225A)<br />

QPH, HQP, HQPH (2 pole,15–125A)<br />

QSH, QSHH, HQS, HQSH (2 pole,100–225A)<br />

QPH, HQP (3 pole,15–100A)<br />

QRH2, HQR2, HQR2H (3 Pole, 100–225A)<br />

Load center<br />

branch circuit breakers<br />

QP, QPH, HQP, QT, QAF, QAFH,<br />

QPF, QPHF, QE, QEH<br />

QP, QPH, HQP, QT, QAF, QAFH,<br />

QPF, QPHF, QE, QEH<br />

to 25,000<br />

Series<br />

WB, WB_U, WBM, WBM_U<br />

WEB, WEB_U, WEBM, WEBM_U<br />

WS_U, WES_U, WTB_U,<br />

WET_U, WXB, WXB_U, WXS,<br />

WXBM, WXBM_U, WBTM,<br />

WBTM_U, BFTM and BFTM_U<br />

JXD2-A, JD6-A, JXD6-A<br />

(2 and 3 pole, 200–400A)<br />

LD6-A, LXD6-A<br />

(2 and 3 pole, 600A)<br />

QPH, HQP<br />

to 42,000<br />

Series<br />

WB, WB_U, WBM, WBM_U,<br />

WEB, WEB_U, WEBM,<br />

WEBM_U, WXB, WXB_U,<br />

WXBM, WXBM_U, WBTM,<br />

WBTM_U, BFTM and BFTM_U<br />

Series<br />

WS_U, WES_U<br />

WXS<br />

QPH, HQP, HQPH (2 pole,15–125A)<br />

QS, QSH, QSHH, HQS, HQSH<br />

(2 pole,100–225A)<br />

QPH, HQP (3 pole,15–100A)<br />

QR2, QRH2, HQR2, HQR2H (3 Pole, 100–225A)<br />

QPH, HQP, HQPH (2 pole,15–125A)<br />

QS, QSH, QSHH, HQS, HQSH<br />

(2 pole,100–225A)<br />

QPH, HQP (3 pole,15–100A)<br />

QP, QPH, HQP, QT, QAF, QAFH,<br />

QPF, QPHF, QE, QEH<br />

QR2, QRH2, HQR2, HQR2H (3 Pole, 100–225A)<br />

Series<br />

WTB_U<br />

WET_U<br />

HQP, HQPH (2 pole,15–125A)<br />

QSHH, HQS, HQSH (2 pole,100–225A)<br />

HQP (3 pole,15–100A)<br />

HQR2, HQR2H (3 Pole, 100–225A)<br />

QP, QPH, HQP, QT, QAF, QAFH,<br />

QPF, QPHF, QE, QEH<br />

QP, QPH, HQP<br />

a Service Entrance Modules:<br />

WB, WEB, WXB, WBT and BFT have 65k AIC breakers factory installed [(JXD2-A, JXD6-A) (LXD6-A) (MXD6) (NXD6) (PXD6) (RXD6)]<br />

WB_U, WEB_U, WXB_U, WBT_U and BFT_U have 100k AIC breakers factory installed [(HJXD6-A) (HLXD6-A) (HMXD6) (HNXD6) (HPXD6) (HRXD6)]<br />

WBM, WEBM, WXBM, WBTM and BFTM have 65k AIC DAS breakers factory installed [(SND6) (SPD6)]<br />

WBM_U, WEBM_U, WXBM_U, WBTM_U and BFTM_U have 100k AIC DAS breakers factory installed [(SHND6) (SHPD6)]<br />

WS_U and WES_U are fused switches (Class T – 300 volt)<br />

WTB_U and WET_U have NO overcurrent protection<br />

3-142<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Mod<br />

Revised on 06/30/19<br />

WML and WMT Commercial Meter Stacks Rating Charts<br />

Use the tables below to determine the correct combination of equipment and circuit breakers for the available fault current.<br />

This chart provides series rating information for the most common applications. For a complete series rating chart please contact<br />

your local sales office.<br />

Available fault current<br />

RMS symmetrical amps at<br />

120/240V max 1-phase, 240V<br />

max 3-Phase Main Modules a Meter module<br />

branch circuit breakers<br />

to 65,000<br />

to 100,000<br />

Series<br />

WB, WB_U, WBM, WBM_U,<br />

WEB, WEB_U, WEBM,<br />

WEBM_U, WXB, WXB_U,<br />

WXBM, WXBM_U, WBTM,<br />

WBTM_U, BFTM and BFTM_U<br />

Series<br />

WS_U, WES_U<br />

WXS<br />

Series<br />

WTB_U<br />

WET_U<br />

Series<br />

WB_U, WBM_U, WEB_U,<br />

WEBM_U, WS_U, WES_U,<br />

WXBM_U, WBTM_U and<br />

BFTM_U<br />

Series<br />

WTB_U, WET_U<br />

WXB_U, WXS<br />

QPH, HQP, HQPH (2 pole,15–125A)<br />

QS, QSH, QSHH, HQS, HQSH (2 pole,100-225A)<br />

QPH, HQP (3 pole,15–100A)<br />

QR2, QRH2, HQR2, HQR2H (3 Pole, 100–225A)<br />

QPH, HQP, HQPH (2 pole,15–125A)<br />

QS, QSH, QSHH, HQS, HQSH<br />

(2 pole,100-225A)<br />

QPH, HQP (3 pole,15–100A)<br />

QR2, QRH2, HQR2, HQR2H (3 Pole, 100–225A)<br />

HQP, HQPH (2 pole,15–125A)<br />

HQS, HQSH (2 pole,100–225A)<br />

HQP (3 pole,15–100A)<br />

HQR2, HQR2H (3 Pole, 100–225A)<br />

HQPH (2 pole,100–125A)<br />

QS, QSH, QSHH, HQS, HQSH (2 pole,100–225A)<br />

QR2, QRH2, HQR2, HQR2H (3 Pole, 100–225A)<br />

HQPH (2 pole,100–125A)<br />

HQSH (2 pole,100–225A)<br />

HQR2H (3 Pole, 100–225A)<br />

Load center<br />

branch circuit breakers to 10,000<br />

QP, QPH, HQP, QT, QAF, QAFH,<br />

QPF, QPHF, QE, QEH<br />

QP, QPH, HQP, QT, QAF, QAFH,<br />

QPF, QPHF, QE, QEH<br />

3 METER<br />

CENTERS<br />

a Service Entrance Modules:<br />

WB, WEB, WXB, WBT and BFT have 65k AIC breakers factory installed [(JXD2-A, JXD6-A) (LXD6-A) (MXD6) (NXD6) (PXD6) (RXD6)]<br />

WB_U, WEB_U, WXB_U, WBT_U and BFT_U have 100k AIC breakers factory installed [(HJXD6-A) (HLXD6-A) (HMXD6) (HNXD6) (HPXD6) (HRXD6)]<br />

WBM, WEBM, WXBM, WBTM and BFTM have 65k AIC DAS breakers factory installed [(SND6) (SPD6)]<br />

WBM_U, WEBM_U, WXBM_U, WBTM_U and BFTM_U have 100k AIC DAS breakers factory installed [(SHND6) (SHPD6)]<br />

WS_U and WES_U are fused switches (Class T – 300 volt)<br />

WTB_U and WET_U have NO overcurrent protection<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 3-143


Power Mod<br />

Notes<br />

METER<br />

CENTERS<br />

3<br />

3-144<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Safety Switches<br />

SPEEDFAX TM<br />

4Section<br />

General Duty Switch<br />

Heavy Duty Switch<br />

c o n t e n t s<br />

Safety Switch Guide Form Specifications 4-2<br />

Feature Comparison 4-3<br />

Enclosure Types 4-4<br />

Catalog Numbering System 4-5<br />

General Duty Safety Switches<br />

Plug Fuse Enclosed Type, 120/240V Fusible—Selection 4-6<br />

60A Special Application Type, 240V Non-Fusible—Selection 4-6<br />

General Duty Switches—Features 4-7<br />

240V Fusible and Non-Fusible—Selection 4-8<br />

Heavy Duty Safety Switches<br />

Heavy Duty Switches—Features 4-9<br />

240V Fusible—Selection 4-10<br />

600V Fusible—Selection 4-11<br />

600V Non-Fusible—Selection 4-12<br />

Type 4/4X and 12 with Viewing Window—Selection 4-13<br />

Special Applications Safety Switches<br />

Type ECS Elevator Control Switches 4-14 – 4-15<br />

4-Pole and 6-Pole—Selection 4-16<br />

Interlocked Receptacle—Selection 4-17<br />

Non-Metallic and 316 Grade Stainless—Selection 4-18<br />

Enclosed Solar PV Disconnects 4-19<br />

Accessories—General and Heavy Duty Switches<br />

Class R Fuse Clips, Class J Fusing, Class T Fuse Adapter Kits 4-20<br />

Neutral Kits, 200% Neutral Kits, Fuse Puller Kits 4-20<br />

Auxiliary Contacts, Copper Lug Kits, 4-21<br />

Equipment Ground Kits, Isolated Ground Kits 4-21<br />

Interchangeable Hubs 4-22<br />

Compression Lug, Neutral Barrier Kits, Lugs and Wire Ranges 4-22<br />

Multiple Padlocks, Kirk-Key Interlocks 4-22<br />

Dimensions and Weights<br />

General and Heavy Duty Switches 4-23 – 4-26<br />

Type 1 and 3R Knockout Diagrams 4-27 – 4-28<br />

Non-Metallic and Receptacle Switch Dimensions 4-29<br />

4-Pole and 6-Pole Switch Dimensions 4-30<br />

Double-Throw Switches<br />

Selection 4-31 – 4-32<br />

Dimensions 4-33<br />

Enclosed Rotary Disconnect Switches 4-34 – 4-35<br />

VBII Safety Switch Replacement Parts 4-36<br />

4 SAFETY<br />

SWITCHES<br />

Window Switch<br />

Scan to connect<br />

online to the<br />

most up-todate<br />

version of<br />

this Section of<br />

SPEEDFAX.<br />

(Section was last modified on 04/08/20)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 4-1


Type VBII Safety Switches<br />

Guide Form Specifications<br />

Revised on 02/28/19<br />

Product Overview<br />

4<br />

SAFETY<br />

SWITCHES<br />

Application<br />

Short Circuit<br />

Withstand<br />

Ratings<br />

General Duty Heavy Duty Double Throw<br />

General Duty Switches are intended for<br />

applications where reliable performance and<br />

continuity of service are needed, but where<br />

duty requirements are not severe and usual<br />

service conditions prevail. (These switches are<br />

intended for use primarily with supply<br />

circuits rated 240V AC or less where the available<br />

fault current is less than 100,000A when<br />

used with Class R or T fuses or 10,000A max.<br />

when used with Class H fuses.)<br />

Suitable for use on systems capable of<br />

delivering not more than 100,000 RMS<br />

symmetrical amperes of fault current as<br />

follows:<br />

Sw. Rating AIC Rating Protective Device a<br />

30-600A 10,000 Circuit Breaker<br />

30-600A 10,000 Class H Fuse<br />

30-600A 100,000 Class R Fuse<br />

100-600A 100,000 Class J or T Fuse<br />

Heavy Duty Switches are intended for use in<br />

applications where:<br />

1. Rugged construction, reliable performance,<br />

continuity of service and ease of maintenance<br />

are emphasized, or<br />

2. Available fault currents higher than 10,000A<br />

are likely to be encountered, such as in<br />

manufacturing plants, mass production<br />

industries, and commercial, institution-al and<br />

other large buildings served by network systems<br />

or transformers of higher capacities.<br />

3. System voltage is 600V AC or DC Max.<br />

4. A Type 12 or 4 / 4X enclosure is required.<br />

Double throw switches are intended to<br />

transfer loads from one power source to<br />

another. All 2 & 3 pole double throw switches<br />

are suitable for use as service equipment. All<br />

are UL Listed. Switches are rated for use on<br />

systems with an available fault current of up<br />

to 10,000 AIC when protected with Class H<br />

fuses or either 100,000 or 200,000 AIC when<br />

protected with Class R, J or Class T fuses. They<br />

can also be used to connect a single source of<br />

power to either of two loads, In this application<br />

it is necessary to field modify fusible switches<br />

so that the fuses are on the load side of the<br />

switching mechanism.<br />

Suitable for use on systems capable of delivering not more than 200,000 RMS symmetrical<br />

amperes of fault current as follows:<br />

Sw. Rating & Tpye AIC Rating Protective Device a<br />

All Heavy Duty & DT 10,000 Circuit Breaker<br />

30-600A HD & DT 10,000 Class H Fuse<br />

60A Compact HD 100,000 Class R, J or T Fuse<br />

GD & 4P DT 100,000 Class R, J or T Fuse<br />

30-600A HD 200,000 Class R, J or T Fuse<br />

30-600A DTF & DTNF DT b 200,000 Class R, J or T Fuse<br />

800 & 1200A HD & DT b 200,000 Class L or T Fuse<br />

Fuses<br />

Fusible switches will accept the following<br />

UL class fuses:<br />

30 “LF” - 30A max plug Fuses<br />

30-600A “GF” Class H & K, Class R with kit<br />

100-600A “GF” Class J-move base<br />

100-200 “GF” Class T with kit<br />

400-600A “GF” Class T-move bases<br />

Fusible switches will accept the following<br />

UL class fuses:<br />

30-600A “HF” Class H & K, Class R with kit<br />

30-600A, 600V “HF” Class J-move base<br />

100-600A, 240V “HF” Class J-move base<br />

100-200A “HF” Class T with kit<br />

400-600A “HF” Class T-move bases<br />

800-1200A “HF” Class L, Class T with kit c<br />

Fusible switches will accept the following<br />

UL class fuses:<br />

30-200A “DT” & “F” Class H & K, Class R with kit<br />

30 & 60A 600V “DT” Class J-move base<br />

100-200A “DT” Class J-move base, Class T with kit<br />

400-600A “DT” Class J-standard, Class T-move bases<br />

400A 240v “F” Class H-standard<br />

400A, 600V & 600A “F” Class T-Standard<br />

Cover <br />

Interlocks<br />

Underwriters’<br />

Laboratories, Inc.<br />

NEMA<br />

Specifications<br />

Seismic<br />

Qualifications<br />

Groundable<br />

Neutral<br />

(All neutrals are<br />

bondable for service<br />

entrance use.)<br />

Voidable – cover interlocks on switches prevent<br />

the switch door from being opened when<br />

in the “ON” position. No cover interlock on<br />

30-60A GD or on plug fuse type switches.<br />

Listed by UL under file #E4776 as enclosed switches and also suitable for use as service equipment (where applicable).<br />

UL98 Enclosed and Deadfront Switches.<br />

Meet NEMA standard KS-1-2001 for type GD<br />

switches.<br />

Voidable dual cover interlocks standard on<br />

all heavy duty switches. Prevents cover from<br />

being opened when switch is in the “ON”<br />

position and prevents switch from being<br />

turned “ON” when door is opened.<br />

Meet NEMA standard KS-1-2001 for type HD<br />

switches.<br />

100-600A GD & all HD switches and “DT” type double throw switches have been tested and comply with the 2010 California Building Code (CBC)<br />

and with the 2009 International Building Code (IBC) - Compliance Level SDS = 1.85 g<br />

Fusible switches have groundable neutral<br />

blocks factory installed. Non-fusible switches<br />

accept field addable neutrals.<br />

All switches (both Fusible and Non-Fusible)<br />

are either supplied with factory installed neutrals<br />

or accept field addable neutrals.<br />

Dual cover interlocks standard on all double<br />

throw switches. Prevents cover from being<br />

opened when switch is in the “ON” position<br />

and prevents switch from being turned “ON”<br />

when door is opened.<br />

Meet NEMA standard KS-1-2001 type GD<br />

for “DTG” & type HD for “DT”, “F” & “NF”<br />

switches.<br />

All except 4 pole switches will accept field<br />

addable neutrals except that “DTG” 100 &<br />

200A switches are also available with factory<br />

installed neutrals.<br />

Padlocks<br />

Padlockable cover latch. OFF padlock<br />

provisions on handle.<br />

Padlockable cover latch and multiple OFF padlock<br />

provisions on handle.<br />

Padlockable cover latch and multiple OFF padlock<br />

provisions on handle.<br />

HP & Load<br />

Break Ratings<br />

All General Duty, Heavy Duty and Double Throw Switches are both load break and horsepower rated.<br />

a The protective device can either be a fuse installed in a<br />

fusible switch or an upstream fuse or circuit breaker<br />

protecting a non-fusible switch. The ampere rating of the<br />

upstream protective device must not exceed the switch<br />

ampere rating.<br />

b All 4 pole and fusible double switches with catalog numbers<br />

starting with “F” are rated 100,000 AIC max.<br />

c Class T kit available for 240V max. applications on 1200A<br />

switches.<br />

4-2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Feature Comparison<br />

Revised on 02/28/19<br />

Product Overview<br />

General<br />

Duty<br />

Heavy<br />

Duty<br />

Double<br />

Throw<br />

Features /<br />

Ratings<br />

b b b 30 thru 600 Amps<br />

b b 800 and 1200 Amps<br />

b b b 240 Volt AC<br />

b b 600 Volt AC<br />

b b b 250 Volt DC<br />

b<br />

600 Volt DC<br />

b b b Double-break visible blade design<br />

(30-200A)<br />

b b b Quick-make, quick-break switching action<br />

(excludes 30A GD)<br />

b<br />

Handle design for hook stick operation<br />

b b b Padlockable cover latch<br />

b b b Padlockable handle<br />

b b Single voidable cover interlock<br />

(excludes 30-60A GD)<br />

b b Dual voidable cover interlock<br />

b b b Type 1 enclosure<br />

b b b Type 3R enclosure<br />

b b Type 12 enclosure<br />

b b Type 4 / 4X enclosures<br />

b b b Generous wiring gutters that meet UL and<br />

NEC wire-bending space requirements<br />

b e b b Lugs suitable for copper or aluminum at<br />

60˚ or 75˚C<br />

b b b CU/AL wire lugs that meet UL 486B<br />

requirements<br />

b b Suitable for field-convertible compression<br />

connectors<br />

b f b b All plated copper current carrying parts<br />

(except lugs)<br />

b b b Spring reinforced Fuse Clips<br />

(except 30-60A GD) b<br />

b b Clear pivoting line terminal shield<br />

b b b Replacement parts (except 30-60A GD)<br />

b<br />

200% neutral available for<br />

purchase separately<br />

b g b ag b ag Provisions for UL Class T, R and H Fuses<br />

b b a Provisions for UL Class J and L Fuses<br />

b b Metal nameplate<br />

b b b Aux. switch kits (excludes 30-60A GD)<br />

b c<br />

Type 4X with stainless steel interior parts<br />

b d b Rolled flange enclosure design (30-200A)<br />

b b Isolated ground kits<br />

on<br />

in operation<br />

off<br />

Double Break Switching Action<br />

Like the time-proven Vacu-Break Design,<br />

the Siemens VBII double break switching<br />

action breaks the arc in two places in<br />

30-600A ratings. This reduces heat<br />

generation and increases switching<br />

speed by doubling the breaking distance.<br />

The result is enhanced performance and<br />

increased longevity. We also provide the<br />

most visible blade design available today.<br />

Unlike conventional knife blade switches,<br />

the blades are self-aligning to ensure<br />

positive contact. In addition, they have<br />

no wear and friction point since the<br />

“electrical hinge” has been eliminated.<br />

The result is a very fast, positive and<br />

reliable switching action for even the<br />

most severe applications.<br />

4 SAFETY<br />

SWITCHES<br />

a 400, 600V & 600A fusible, double-throw switches<br />

accept only Class J or T fuses. Only 800 & 1200A HD<br />

switches will accept Class L fuses.<br />

b 30-60A general duty switches have fuse clips<br />

constructed of spring type copper.<br />

c 30-200A Type VBII in stainless steel enclosures.<br />

d 100-200A.<br />

e 60A only suitable for Cu at 75°.<br />

f 200A general duty switches have aluminum neutral<br />

assemblies.<br />

g 100-600A GD & DT and 100-1200A HD switches will<br />

accept Class T fuses.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 4-3


Safety Switches<br />

General Duty and Heavy Duty<br />

Revised on 02/28/19<br />

Product Overview<br />

4<br />

SAFETY<br />

SWITCHES<br />

Enclosure Types<br />

h A Type 1 enclosures are intended for indoor use primarily to<br />

provide protection against contact with the enclosed equipment<br />

in locations where unusual service conditions do not exist.<br />

h B Type 3R enclosures are intended for outdoor use primarily<br />

to provide a degree of protection against falling rain and sleet<br />

and must remain undamaged by the formation of ice on the<br />

enclosure. They are not intended to provide protection against<br />

conditions such as dust, internal condensation, or internal icing.<br />

h C Type 4, 4X enclosures are intended for indoor or outdoor<br />

use primarily to provide a degree of protection against<br />

windblown dust, rain, splashing water and hose-directed water.<br />

They are not intended to provide protection against conditions<br />

such as internal condensation or internal icing. Also meets<br />

4X definition by providing a high degree of protection<br />

against corrosion. Siemens 30-200A stainless steel 4X switches<br />

are supplied stainless interior parts and hardware as standard.<br />

h D Type 4 enclosures are intended for indoor or outdoor use<br />

primarily to provide a degree of protection against windblown<br />

dust, rain, splashing water and hose-directed water. They are<br />

not intended to provide protection against conditions such as<br />

internal condensation or internal icing.<br />

h E Type 12 a enclosures are intended for indoor use primarily to<br />

provide a degree of protection against dust, falling dirt and<br />

dripping water. They are not intended to provide protection<br />

against conditions such as internal condensation.<br />

Type 7/9 enclosures for use in hazardous locations. Use with<br />

molded case switches listed in Section 7.<br />

h A <br />

hB<br />

Load Break Ratings<br />

All Siemens safety switches are load break rated. The load<br />

break rating is assigned by UL after the switching unit has<br />

successfully performed the following tests:<br />

Number of<br />

Switch ON/OFF Number of Operations<br />

Ampere Operations With Without<br />

Rating per Minute Current Current Total<br />

30–100 6 6000 4000 10000<br />

200 5 6000 2000 8000<br />

400 4 1000 5000 6000<br />

600 3 1000 4000 5000<br />

800 2 500 3000 3500<br />

1200 1 500 2000 2500<br />

Horsepower Ratings<br />

All Siemens safety switches, where appropriate, are horsepower<br />

rated. Ratings are approved by UL only after the<br />

switching unit has undergone testing to determine its acceptability<br />

which includes repeated interruption of the locked rotor<br />

current of the motor for which it is to be rated as follows:<br />

Max HP Number of ON/OFF Number of Cycles<br />

Rating Operations per minute of Operation<br />

100 6 50<br />

500 1 10<br />

h C hD<br />

h E <br />

Non- Fusible Safety Switch AIC Ratings<br />

When Protected by a Circuit Breaker <br />

Breaker Frame Non-Fused Switch<br />

UL Listed Short Circuit<br />

Current Rating<br />

NEG, NGB, ED4 30 DT (240V) 18 kA Thru 240 VAC<br />

NEB, NEG, NGG, 100A GD & DT (240V) 18 kA Thru 240 VAC<br />

NGB, ED4<br />

NEB, NEG, NGG, 30-100A HD & DT (600V) 18 kA Thru 480 VAC<br />

NGB, ED4<br />

ED6 30-100A HD & DT (600V) 18 kA Thru 600 VAC<br />

FD6-A, JD6-A 200A HD & DT (600V) 18 KA Thru 600 VAC<br />

JD6-A, LD6-A 400A GD & DT (240V) 18 kA Thru 240 VAC<br />

JD6-A, LD6-A 400A HD & DT (600V) 18 kA Thru 600 VAC<br />

LD6-A 600A GD & DT (240V) 25kA Thru 240 VAC<br />

LD6-A 600A HD & DT (600V) 25kA Thru 600 VAC<br />

NNG 1200A HD & DT (600V) 25 kA Thru 600 VAC<br />

VBII Type 12 switches are also rated 3R & 3S for outdoor use. Type 3R is defined in B<br />

above. 3S rated enclosures provide a degree of protection against windblown dust and<br />

allow operation when the enclosure is ice laden.<br />

All switches above are rated at 10 KA when protected by any UL Listed CB<br />

Circuit breaker trip rating must not exceed switch ampere rating<br />

4-4<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Catalog Numbering System<br />

Type VBII Safety Switch Catalog Numbering System<br />

Revised on 02/28/19<br />

Product Overview<br />

H F 3 6 4 N R CU A<br />

Switch Type<br />

L = General Duty<br />

Plug Fused<br />

LNF222RA (no hub provision)<br />

G = Gen. Duty<br />

H = Heavy Duty<br />

DT = Double Throw<br />

DTG = General Duty DT<br />

Fused or Non-Fused<br />

F = Fused<br />

NF = Non-Fused<br />

Number of Poles<br />

1 = 1<br />

2 = 2<br />

3 = 3<br />

Voltage<br />

4 = 4<br />

6 = 6<br />

1 = 120V or 120/240V<br />

2 = 240V<br />

6 = 600V<br />

Amperes<br />

1 = 30A<br />

2 = 60A<br />

3 = 100A<br />

4 = 200A<br />

5 = 400A<br />

6 = 600A<br />

7 = 800A<br />

8 = 1200A<br />

Series Type<br />

A = 30A, 60A, 400A, 600A<br />

Omit = 30A-200A, 800A-1200A<br />

Special Applications With:<br />

CH = Crouse-Hinds Receptacle<br />

CJ = Factory J Fuse Spacings<br />

CR = Class R Clips Installed<br />

CU = Factory-Installed Copper Lugs<br />

G = Factory-Installed Ground Bar<br />

H = Height or Size Reduced<br />

L = Oversized Enclosure<br />

PN = Pyle-National Receptacle<br />

PV = Photovoltaic rated<br />

PVPG = Photovoltaic rated, Positive<br />

Ground<br />

W = Viewing Window<br />

Enclosure Type<br />

Omit = Type 1, Indoor<br />

R = Type 3R, Outdoor<br />

S = Type 4 / 4X, Stainless Steel<br />

SS = Type 4 / 4X, 316 Grade<br />

Stainless Steel<br />

X = Type 4 / 4X, Non-Metallic<br />

J = Type 12, Industrial<br />

XL = Type 4/4X Non-Metallic<br />

Less Line & Load Lugs<br />

With or Without Neutral<br />

Omit = Less Neutral<br />

N = With Neutral<br />

4 SAFETY<br />

SWITCHES<br />

Type VBII Accessories Catalog Numbering System<br />

H R 6 4<br />

A<br />

Switch Type<br />

H = Heavy Duty<br />

G = General Duty <br />

Series Type<br />

A = 400A, 600A<br />

Omit = 30A-200A, 800A-1200A<br />

Accessory Type<br />

A1 = Auxiliary Switch 1/NO and 1/NC<br />

A2 = Auxiliary Switch 2/NO and 2/NC<br />

A3 = Auxiliary Switch Low Current<br />

CL = Compression Lug Barrier / Mounting Kit<br />

CU = Copper Lug <br />

G = Ground Lug Kit<br />

G2 = Insulated Ground Lug Kit<br />

J = Class J Fuse Kit <br />

LC = Copper Lug Kit <br />

N = Neutral<br />

N2 = 200% Neutral <br />

NCM = Field Replacement Lug Kit <br />

P = Fuse Puller Kit<br />

R = Class R - Fuse Clip Kit<br />

T = Class T - Fuse Kit<br />

Amperes<br />

1 = 30A<br />

2 = 60A<br />

12 = 30/60A<br />

3 = 100A<br />

23 = 60/100A<br />

123 = 30/60/100A<br />

Maximum Voltage<br />

2 = 240V Max <br />

6 = 600V Max<br />

1234 = 30/60/100/200A<br />

4 = 200A<br />

5 = 400A<br />

56 = 400/600A<br />

5678 = 400/600/800/1200A<br />

6 = 600A<br />

78 = 800/1200A<br />

Note: Catalog numbering systems above do not apply to<br />

4-pole & Type “F” & “FR” double throw switches<br />

& accessories.<br />

For 400A, 600A use 680V max accessories except<br />

for T Fuse Kit.<br />

Only offered for 400A, 600A.<br />

For 30A-200A, 800A-1200A.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 4-5


General Duty Enclosed Switches<br />

Plug Fuse and 60A Special Application Type<br />

Revised on 09/30/19<br />

Selection<br />

4<br />

Features<br />

b Compact size<br />

b Horsepower rated<br />

b Indoor and outdoor enclosures<br />

b Quick make-quick break mechanism<br />

b Visible “ON”-“OFF” indications<br />

b Padlock-off handle feature<br />

b Door padlock provision<br />

b Bondable neutral (where indicated)<br />

b Lugs suitable for copper or aluminum wire<br />

b UL Listed<br />

b Fuses — not included<br />

b Switches accept Edison base plug<br />

fuses<br />

b Hubs — see page 4-22<br />

b Lugs — see page 4-22<br />

SAFETY<br />

SWITCHES<br />

Dimensions (inches)<br />

Type Height Width Depth<br />

1 8 1 ⁄4 5 1 ⁄2 3<br />

3R 8 1 ⁄4 5 3 ⁄8 3 1 ⁄8<br />

Wire Range Table<br />

Switch Type<br />

Wire Range<br />

120/240 Volt Fusible Cu/Al<br />

30 Amp #14 to #8 AWG d<br />

240 Volt Non-Fusible Cu<br />

60 Amp #14 to #6 AWG<br />

Indoor — Type 1 Outdoor — Type 3R<br />

a<br />

Horsepower Ratings<br />

Ampere Ship. Wt. (lbs.) Ship Wt. (lbs.)<br />

1-Phase, 2-Wire<br />

Rating Catalog Number Pkg. of 10 Catalog Number Pkg. of 10 Standard Maximum<br />

120/240 Volt Fusible<br />

1-Pole and Solid Neutral b<br />

120 Volt — 1-Phase, 2-Wire<br />

30 LF111N 35 LF111NR 35 1<br />

⁄2 2<br />

2-Pole and No Neutral<br />

120/240 Volt — 1-Phase, 2-Wire<br />

30 Use 2-Pole and Solid Neutral<br />

2-Pole and Solid Neutral b<br />

120/240 Volt — 1-Phase, 3-Wire<br />

30 LF211N 35 LF211NR 35 1 1 ⁄2 3<br />

240 Volt Non-Fusible<br />

2-Pole Special Application Switch 1 or 2-Pole — No Fuse 240 Volt — 1-Phase, 2-Wire<br />

60 — — LNF222RA c 30 — 10<br />

60 — — LNF222RL e 40 3 10<br />

For inches / millimeters conversion, multiply inches by<br />

25.4.<br />

a Dual horsepower ratings:<br />

Std. — applies when non-time delay plug fuses<br />

are installed.<br />

Max — applies when time-delay plug fuses are installed.<br />

b Has service entrance label.<br />

UL Listed as “Enclosed Switches” (suitable for use as<br />

service equipment where indicated) under File #E4776.<br />

(NEMA) — Type G.D.<br />

Federal Spec. — W-S-865C — type LD or type NDS<br />

c Bottom cable entry and exit only. No hub provision<br />

supplied. Ground lug is included and factory installed.<br />

d Line lugs will accept and are UL approved for #14 to #6<br />

Cu/Al cable.<br />

e Legacy style, oversize enclosure. Ground lug is<br />

included and factory installed.<br />

4-6<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category GDSS


General Duty Safety Switches<br />

Features (60-600A)<br />

Revised on 02/28/19<br />

Product Overview<br />

11 5<br />

10<br />

9<br />

6<br />

3<br />

4 SAFETY<br />

SWITCHES<br />

1<br />

8<br />

4<br />

7<br />

2<br />

1. Cover interlock<br />

2. Tangential knockouts 100-600A<br />

for easy conduit lineup<br />

3. Quick-make, quick-break operating<br />

mechanism that ensures positive<br />

operation<br />

4. Provisions for T, R, J, H, and K<br />

class fuses (T & J 100-600A)<br />

5. Wiring gutters that meet or<br />

exceed NEC wire-bending space<br />

requirements<br />

6. Visible blade, double-break switch<br />

action<br />

7. Positive 2 or 3 point mounting<br />

8. Highly visible red handle grip<br />

9. Informative door labeling which<br />

includes replacement parts list<br />

10. Handle and cover padlocking<br />

provisions<br />

11. 100A and above have sidehinged<br />

door that opens 180<br />

degrees for easier wiring<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 4-7


General Duty Safety Switches<br />

Revised on 10/31/19<br />

Selection<br />

4<br />

SAFETY<br />

SWITCHES<br />

System<br />

Ampere<br />

Rating<br />

240 Volt Fusible<br />

Indoor — Type 1<br />

Catalog Number<br />

2-Pole, 2-Fuse, and Solid Neutral bcd<br />

Ship Wt.<br />

(lbs.)<br />

Std. Pkg<br />

Outdoor — Type 3R<br />

Catalog Number<br />

Ship Wt.<br />

(lbs.)<br />

Std. Pkg<br />

Horsepower Rating a<br />

240V AC 250<br />

1-Phase, 2-Phase, 3-Phase, Volt<br />

2-Wire 4-Wire 3-Wire DC<br />

Std. Max. Std. Max. Std. Max. Std.<br />

240 Volt AC/250 Volt DC<br />

030 GF221NA 030 g GF221NRA e 30 g 01 1 ⁄2 03 — — 03 007 1 ⁄2 05<br />

060 GF222NA 020 f GF222NRA e 20 f 03 10 — — 07 1 ⁄2 015 10<br />

100 GF223N 023 GF223NR 23 07 1 ⁄2 15 — — 15 030 20<br />

200 GF224N 047 GF224NR 48 15 — — — 25 060 40<br />

3-Pole, 3-Fuse, and Solid Neutral d<br />

240 Volt AC/250 Volt DC<br />

030 GF321NA 030 g GF321NRA e 030 g 01 1 ⁄2 03 — — 03 007 1 ⁄2 05<br />

060 GF322NA 020 f GF322NRA e 020 f 03 10 — — 07 1 ⁄2 015 10<br />

100 GF323N 25 GF323NR 025 07 1 ⁄2 15 — — 15 030 20<br />

200 GF324N 49 GF324NR 050 15 — — — 25 060 40<br />

400 GF325NA 94.6 GF325NRA 94.6 15 — — — 50 125 50<br />

600 GF326NA 95.6 GF326NRA 95.6 15 — — — 75 200 —<br />

240 Volt Non-Fusible cd<br />

2-Pole or 3-Pole<br />

240 Volt AC/250 Volt DC<br />

030 GNF221A 020 g GNF221RA e 020 g — 03 — — — — 05<br />

030 GNF321A i 020 g GNF321RA ei 020 g — 03 — — 007 1 ⁄2 — 05<br />

030 GNF321LA j 030 g GNF321RLA ej 030 g — 03 — — 007 1 ⁄2 — 05<br />

060 GNF222A 030 g GNF222RA e 030 g — 10 — — 015 — 10<br />

060 GNF322A 030 g GNF322RA e 030 g — 10 — — 015 — 10<br />

100 GNF323 023 GNF323R 024 — 15 — — 030 — 20<br />

200 GNF324 046 GNF324R 047 — 15 — — 060 — 40<br />

400 GNF325A 114 Use 600V Switch — HNF365RA — 15 — — 125 — 50<br />

600 GNF326A 116 Use 600V Switch — HNF366RA — 15 — — 200 — —<br />

a Dual horsepower ratings: Std.- applies when non-time<br />

delay fuses are installed. Max.- applies when timedelay<br />

fuses are installed.<br />

b These switches are UL-listed for application on<br />

grounded B-phase systems.<br />

c Suitable for use on 3-phase motor loads.<br />

d Service entrance labeled.<br />

e Has provision for ECHA type hub.<br />

f 5 switches per standard package.<br />

g 10 switches per standard package.<br />

h Height reduced switch (45.25 rather than 56 inches in<br />

height) for use with 500MCM or smaller conductors.<br />

i Not suitable for service entrance.<br />

j Indicates oversized enclosure.<br />

4-8<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category GDSS


Heavy Duty Safety Switches<br />

Features<br />

15<br />

3<br />

2<br />

20<br />

9<br />

11<br />

16<br />

17<br />

4<br />

1<br />

18<br />

6<br />

19<br />

13<br />

5<br />

4 SAFETY<br />

SWITCHES<br />

8<br />

14<br />

12<br />

7<br />

1. Quick-make, quick-break operating mechanism<br />

that ensures positive operation.<br />

2. Visible blade, double-break switching action.<br />

3. Arc chutes dissipate heat and prolong switch life.<br />

4. Highly visible red handle grip.<br />

Designed for hook stick operation.<br />

12. Unique enclosure design increases rigidity and<br />

prevents cuts and scrapes to conductors and<br />

installer’s hands.<br />

13. Spring reinforced fuse clips that assure reliable<br />

contact for cool operation.<br />

14. Door latch securely holds door closed and<br />

allows cover padlocking.<br />

10<br />

5. Defeatable dual cover interlock.<br />

6. Center punch provided for field drilling<br />

to allow ON padlocking.<br />

7. Handle can be padlocked in the OFF position<br />

with up to (3) padlocks with 5/16" hasps.<br />

8. Generous top, bottom and side gutters that<br />

meet or exceed NEC wire-bending space<br />

requirements.<br />

9. Informative door labeling which includes<br />

replacement parts list.<br />

10. Tangential knockouts through 600A for easy<br />

conduit lineup.<br />

11. Side-hinged door that opens past 180 degrees<br />

for easier wiring.<br />

15. Front removable mechanical lugs that are<br />

suitable for CU/AI 60 or 75° C conductors.<br />

16. Lugs are field convertible to copper<br />

body and to a wide variety of compression<br />

connectors.<br />

17. Hinged clear line terminal shield<br />

with probe holes for inspecting or<br />

testing line side terminals.<br />

18. Embossed aluminum nameplate on Heavy<br />

Duty Switches provides highly visible ON/OFF<br />

indication.<br />

19. Drawn cover for increased rigidity<br />

and resistance to abuse.<br />

20. Top key hole and bottom mounting holes<br />

provide easy 2 or 3 point mounting.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 4-9


Heavy Duty Safety Switches<br />

Selection<br />

4<br />

SAFETY<br />

SWITCHES<br />

System<br />

Ampere<br />

Rating<br />

Indoor — Type 1<br />

Catalog Number<br />

Ship Wt.<br />

(lbs.)<br />

Std. Pkg<br />

Outdoor — Type 3R<br />

Catalog Number<br />

Ship Wt.<br />

(lbs.)<br />

Std. Pkg<br />

Horsepower Rating a<br />

240V AC<br />

1-Phase,<br />

2-Wire<br />

2-Phase,<br />

4-Wire<br />

3-Phase,<br />

3-Wire<br />

250<br />

Volt<br />

DC<br />

Std. Max. Std. Max. Std. Max. Std.<br />

240 Volt Fusible e<br />

2-Pole, 2-Fuse, and Solid Neutral c (Also used for 2-Pole, 2-Wire Applications) 240 Volt AC/250 Volt DC<br />

30 HF221N 012 HF221NR 013 01 1 ⁄2 03 — — 003 007 1 ⁄2 05<br />

60 HF222N 018 HF222NR 019 03 10 — — 007 1 ⁄2 015 10<br />

100 HF223N 023 HF223NR 024 07 1 ⁄2 15 — — 015 030 20<br />

200 HF224N 047 HF224NR 048 15 — — — 025 060 40<br />

400 HF225NA 91.1 HF225NRA 91.1 15 — — — 050 125 50<br />

600 HF226NA 95.6 HF226NRA 95.6 15 — — — 075 200 50<br />

800 HF227N 365 HF227NR 365 — — — — 100 250 50<br />

1200 HF228Nn 385 HF228NRn 385 — — — — 100 250 50<br />

3-Pole, 3-Fuse, and Solid Neutral (Also used for 3-Pole, 3-Wire Applications) 240 Volt AC/250 Volt DC<br />

240 Volt Fusible e<br />

2-Pole, 2-Fuse d<br />

3-Pole, 3-Fuse d<br />

0030 HF321N 014 HF321NR 015 01 1 ⁄2 03 — — 003 007 1 ⁄2 05<br />

0060 HF322N 019 HF322NR 020 03 10 — — 007 1 ⁄2 015 10<br />

0100 HF323N 025 HF323NR 026 07 1 ⁄2 15 — — 015 030 20<br />

0200 HF324N 049 HF324NR 050 15 — — — 025 060 40<br />

0400 HF325NA 94.6 HF325NRA 94.6 15 — — — 050 125 50<br />

0600 HF326NA 99.6 HF326NRA 99.6 15 — — — 075 200 50<br />

0800 HF327N 375 HF327NR 375 — — — — 100 250 50<br />

1200 HF328N 395 HF328NR 388 — — — — 100 250 50<br />

240 Volt AC/250 Volt DC<br />

Type 4/4X Stainless <br />

Type 12 Industrial f<br />

0030 HF221S 013 HF221J 013 01 1 ⁄2 03 — — 003 007 1 ⁄2 05<br />

0060 HF222S 019 HF222J 019 03 10 — — 007 1 ⁄2 015 10<br />

0100 HF223S 024 HF223J 024 07 1 ⁄2 15 — — 015 030 20<br />

0200 HF224S 048 HF224J 048 15 — — — 025 060 40<br />

(Also used for 2-Pole, 2-Wire Applications in 400–800A Ratings) 240 Volt AC/250 Volt DC<br />

0030 HF321S 014 HF321J 014 01 1 ⁄2 3 — — 003 007 1 ⁄2 —<br />

0060 HF322S 020 HF322J 020 3 10 — — 007 1 ⁄2 015 10<br />

0100 HF323S 025 HF323J 025 07 1 ⁄2 15 — — 015 030 20<br />

0200 HF324S 049 HF324J 049 15 — — — 025 060 40<br />

400 HF325SA 93 HF325JA 93 15 — — — 50 125 50<br />

400 HF325SSA 93 — — 15 — — — 50 125 50<br />

600 HF326SA 98 HF326JA 98 15 — — — 75 200 50<br />

600 HF326SSA 98 — — 15 — — — 75 200 50<br />

800 HF327S■ 370 HF327J■ 365 — — — — 100 250 50<br />

n Built to order. Allow 3-5 weeks for delivery.<br />

Height reduced switch (45.25 rather than 56 inches in<br />

height) for use with 500MCM or smaller conductors.<br />

Dual horsepower ratings: Std.- applies when non-time<br />

delay fuses are installed. Max.- applies when timedelay<br />

fuses are installed.<br />

These switches are UL-listed for application on<br />

grounded B-phase systems and are suitable for<br />

3-phase motor applications.<br />

When a neutral is required use a field installed<br />

neutral kit.<br />

Suitable for use as service entrance equipment.<br />

Also rated Type 3S/3R.<br />

304 grade stainless steel. For switches with enclosures<br />

constructed from 316 grade stainless steel, see page 4-18.<br />

4-10<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category HDSS


Heavy Duty Safety Switches<br />

Selection<br />

System<br />

Ampere<br />

Rating<br />

600 Volt Fusible e<br />

2-Pole, 2-Fuse c<br />

3-Pole, 3-Fuse<br />

Indoor — Type 1<br />

Catalog Number<br />

Ship Wt.<br />

(lbs.)<br />

Std. Pkg<br />

Outdoor — Type 3R<br />

Catalog Number<br />

Ship Wt.<br />

(lbs.)<br />

Std. Pkg<br />

Horsepower Rating <br />

480V AC<br />

1-Phase, 3-Phase,<br />

2-Wire 3-Wire<br />

600V AC<br />

1-Phase,<br />

2-Wire<br />

3-Phase,<br />

3-Wire<br />

Std. Max. Std. Max. Std. Max. Std. Max.<br />

250<br />

Volt<br />

DC<br />

600<br />

Volt<br />

DC<br />

480 Volt AC/600 Volt AC/600 Volt DC<br />

0030 HF261 015 HF261R 015 03 07 1 ⁄2 — — 03 10 — — 05 15<br />

0060 HF262 020 HF262R 020 05 20 — — 10 25 — — 10 30<br />

0100 HF263 026 HF263R 027 10 30 — — 15 40 — — 20 50<br />

480 Volt AC/600 Volt AC/250 Volt DC a<br />

0030 HF361 14 HF361R 015 03 07 1 ⁄2 005 015 03 10 007 1 ⁄2 020 05 —<br />

0030 HF361L g 19 HF361RL g 020 03 07 1 ⁄2 005 015 03 10 007 1 ⁄2 020 05 —<br />

0060 HF362 19 HF362R 020 05 20 015 030 10 25 015 050 10 30 <br />

0060 — — HF362RL 025 05 20 015 030 10 25 015 050 10 30 <br />

0100 HF363 24 HF363R 025 05 20 025 060 15 40 030 075 20 50 <br />

0200 HF364 48 HF364R 049 25 50 050 125 30 50 060 150 40 50<br />

0400 HF365A 93 HF365RA 157 — — 100 250 — — 125 350 50 —<br />

0600 HF366A 98 HF366RA 161 — — 150 400 — — 200 500 50 —<br />

0800 HF367 365 HF367R 365 — — 200 500 — — 250 500 50 —<br />

1200 HF368 383 HF368R 385 — — 200 500 — — 250 500 50 —<br />

3-Pole, 3-Fuse and Solid Neutral<br />

480 Volt AC/600 Volt AC/250 Volt DC a<br />

0030 HF361N 014 HF361NR 015 03 07 1 ⁄2 005 015 03 10 007 1 ⁄2 020 05 —<br />

0060 HF362N 019 HF362NR 020 05 20 015 030 10 25 015 050 10 30 <br />

0100 HF363N 025 HF363NR 026 10 30 025 060 15 40 030 075 20 50 <br />

0200 HF364N 049 HF364NR 050 25 50 050 125 30 50 060 150 40 50<br />

0400 HF365NA 94.6 HF365NRA 94.6 — — 100 250 — — 125 350 50 —<br />

0600 HF366NA 99.6 HF366NRA 99.6 — — 150 400 — — 200 500 50 —<br />

0800 HF367N 375 HF367NR 375 — — 250 500 — — 250 500 50 —<br />

1200 HF368N 395 HF368NR 388 — — 250 500 — — 250 500 50 —<br />

600 Volt Fusible e (For 2-Pole Applications use outside poles of 3-Pole Switches)<br />

2-Pole, 2-Fuse c<br />

480 Volt AC/600 Volt AC/600 Volt DC<br />

Type 4/4X Stainless <br />

Type 12 Industrial f<br />

0030 HF261S 015 HF261J■ 015 03 07 1 ⁄2 — — 03 10 — — 05 15<br />

0060 HF262S 020 HF262Jn 020 05 20 — — 10 25 — — 10 30<br />

0100 HF263Sn 027 HF263Jn 027 10 30 — — 15 40 — — 20 50<br />

4 SAFETY<br />

SWITCHES<br />

3-Pole, 3-Fuse<br />

n Built to order. Allow 3-5 weeks for delivery.<br />

a 60-600A 3-Pole switches are also rated 600V DC.<br />

b Height reduced switch (45.25 rather than 56 inches in<br />

height) for use with 500MCM or smaller conductors.<br />

c Use 3-Pole switch for 200A applications.<br />

Product Category HDSS<br />

d Dual horsepower ratings: Std.- applies when non-time<br />

delay fuses are installed. Max.- applies when timedelay<br />

fuses are installed.<br />

e Suitable for use as service entrance equipment except on<br />

1200 Amp solidly grounded wye systems per NEC 230.95.<br />

f Also rated Type 3S/3R.<br />

480 Volt AC/600 Volt AC/250 Volt DC a<br />

0030 HF361S 013 HF361J 014 — — 005 015 — — 007 1 ⁄2 020 05 —<br />

0060 HF362S 020 HF362J 020 — — 015 030 — — 015 050 10 30 h<br />

0100 HF363S 025 HF363J 025 — — 025 060 — — 030 075 20 50 h<br />

0200 HF364S 049 HF364J 049 — — 050 125 — — 060 150 40 50<br />

0400 HF365SA 93 HF365JA 93 — — 100 250 — — 125 350 50 —<br />

0400 HF365SSA 93 — — — — 100 250 — — 125 350 50 —<br />

0600 HF366SA 98 HF366JA 98 — — 150 400 — — 200 500 50 —<br />

0600 HF366SSA 98 — — — — 150 400 — — 200 500 50 —<br />

0800 HF367S 370 HF367Jn 365 — — 200 500 — — 250 500 50 —<br />

1200 HF368Sn 388 HF368Jn 388 — — 250 500 — — 250 500 50 —<br />

g Indicates oversized enclosure (30A switch with 60A<br />

lugs in a 60A enclosure or 60A switch with 100A lugs<br />

in a 100A enclosure).<br />

h 600V DC & 600V DC horsepower rating shown<br />

requires (2) poles to be connected in series.<br />

304 grade stainless steel. For switches with enclosures<br />

constructed from 316 grade stainless steel, see page 4-18.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 4-11


Heavy Duty Safety Switches<br />

Selection<br />

Indoor — Type 1 Outdoor — Type 3R Horsepower Rating<br />

Catalog<br />

Number<br />

Ship<br />

Wt. (lbs.)<br />

Catalog<br />

Number<br />

Ship<br />

Wt. (lbs.)<br />

240 Volt<br />

1-Phase 3-Phase<br />

480 Volt<br />

1-Phase 3-Phase<br />

600 Volt<br />

1-Phase 3-Phase<br />

4<br />

System<br />

Ampere<br />

Rating<br />

250V<br />

DC<br />

600V<br />

DC<br />

SAFETY<br />

SWITCHES<br />

600 Volt Non-Fusible d<br />

2-Pole <br />

480 Volt AC / 600 Volt AC / 600 Volt DC<br />

30 HNF261 12 HNF261R 13 — — 07 1 ⁄2 — 10 — 5 15<br />

60 HNF262 19 HNF262R 20 — — 20 — 25 — 10 30<br />

100 HNF263 24 HNF263R 25 — — 30 — 40 — 20 50<br />

3-Pole<br />

480 Volt AC / 600 Volt AC / 250 Volt DC<br />

30 HNF361 12 HNF361R 13 5 10 07 1 ⁄2 20 10 30 5 —<br />

30 — — HNF361RL f 19 5 10 07 1 ⁄2 20 10 30 5 —<br />

60 HNF362H b 11 HNF362RH b 11 10 20 20 50 20 40 10 —<br />

60 HNF362 a 18 HNF362R a 19 10 20 20 50 25 60 10 30 g<br />

60 — — HNF362RL f 24 10 20 20 50 25 60 10 30 g<br />

100 HNF363 a 23 HNF363R a 24 15 40 30 75 40 100 20 50 g<br />

200 HNF364 a 46 HNF364R a 47 15 60 50 125 50 150 40 50<br />

400 HNF365A a 75 HNF365RA a 75 15 125 50 250 50 350 50 —<br />

600 HNF366A a 77 HNF366RA a 77 15 200 50 400 50 500 50 —<br />

800 HNF367 295 HNF367R 295 15 250 50 500 50 500 50 —<br />

1200 HNF368 305 HNF368R 307 15 250 50 500 50 500 50 —<br />

600 Volt Non-Fusible d<br />

2-Pole c<br />

480 Volt AC / 600 Volt AC / 600 Volt DC<br />

Type 4 / 4X Stainless Type 12 Industrial <br />

30 HNF261S 13 HNF261J 13 — — 07 1 ⁄2 — 10 — 5 15<br />

60 HNF262S 20 HNF262J 20 — — 20 — 25 — 10 30<br />

100 HNF263Sn 25 HNF263Jn 25 — — 30 — 40 — 20 50<br />

3-Pole<br />

480 Volt AC / 600 Volt AC / 250 Volt DC<br />

30 HNF361S 13 HNF361J 13 5 10 07 1 ⁄2 20 10 30 5 —<br />

60 HNF362SH b 15 HNF362JH b 14 10 20 20 50 20 40 10 —<br />

60 HNF362S a 19 HNF362J a 19 10 20 20 50 25 60 10 30 g<br />

100 HNF363S a 24 HNF363J a 24 15 40 30 75 40 100 20 50 g<br />

200 HNF364S a 47 HNF364J a 47 15 60 50 125 50 150 40 50<br />

400 HNF365SA a 75 HNF365JA a 75 15 125 50 250 50 350 50 —<br />

400 HNF365SSA 75 — — 15 125 50 250 50 350 50 —<br />

600 HNF366SA a 77 HNF366JA a 77 15 200 50 400 50 500 50 —<br />

600 HNF366SSA 77 — — 15 200 50 400 50 500 50 —<br />

800 HNF367S 295 HNF367Jn 295 15 250 50 500 50 500 50 —<br />

1200 HNF368Sn 310 HNF368Jn 310 15 250 50 500 50 500 50 —<br />

n Built to order. Allow 3-5 weeks for delivery.<br />

a 60-600A 3-Pole switches are also rated 600V DC.<br />

b Compact switch (11.1"H, 6.6"W box less cover and handle).<br />

Short circuit withstand rating—100,000 RMS sym. amps.<br />

c Use 3-Pole switch for 200A application.<br />

d Suitable for use as service entrance equipment except for<br />

1200 when used on a 480 or 600V grounded wye system.<br />

e Also rated type 3S / 3R.<br />

f Indicates oversized enclosure (30A switch in a 60A<br />

enclosure or a 60A switch in a 100A enclosure.<br />

g 600V DC and 600V DC horsepower rating shown<br />

requires (2) poles to be connected in series.<br />

304 grade stainless steel. For switches with enclosures<br />

constructed from 316 grade stainless steel, see page 4-18.<br />

4-12<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category HDSS


Heavy Duty Safety Switches<br />

Type 4/4X & 12 with Viewing Window<br />

Selection<br />

Description<br />

30–600A, 3-pole 600V max. in fusible and<br />

non-fusible versions in Type 4/4X stainless<br />

steel and Type 12 enclosures.<br />

All allow viewing of visible blade position.<br />

30–200A also allow viewing of indicating<br />

type fuses.<br />

Features<br />

b Rugged installer-friendly enclosure<br />

design features a gasket flange with<br />

continuously welded seams<br />

b Tool-free cover latches<br />

b Two, three and four point mounting<br />

b Metal handle with large insulating grip<br />

features a positive stop in both ON and<br />

OFF position<br />

b Ground lugs provided as standard<br />

b Type 12 enclosures are fabricated from<br />

galvanized steel and are also rated for<br />

3R/3S outdoor applications<br />

b Type 4X stainless steel switches<br />

(30–200A) are provided with stainless<br />

steel interior parts<br />

b The widest range of accessories<br />

available including 200% neutrals,<br />

gold plated PLC auxiliary contacts<br />

and isolated ground kits<br />

System<br />

Ampere<br />

Rating<br />

Catalog Number<br />

Ship<br />

Wt. (lbs.)<br />

Maximum Horsepower Rating <br />

240V AC 480V AC 600V AC<br />

1-Phase, 2-Wire 3-Phase, 3-Wire 3-Phase, 3-Wire 3-Phase, 3-Wire<br />

3-Pole, 3-Wire Fusible, Type 3R 600 Volt AC / 250 Volt DC <br />

30 HF361RW 17 3 7 1 ⁄2 15 20 5 —<br />

60 HF362RW 22 10 15 30 50 10 30 <br />

250V<br />

DC<br />

600V<br />

DC<br />

4 SAFETY<br />

SWITCHES<br />

3-Pole, 3-Wire Non-Fusible, Type 3R <br />

600 Volt AC / 250 Volt DC <br />

30 HNF361RW 14 3 10 20 30 5 —<br />

60 HNF362RW 21 10 20 50 60 10 30 <br />

3-Pole, 3-Wire Fusible, Type 12 600 Volt AC / 250 Volt DC <br />

30 HF361JW 17 3 7 1 ⁄2 15 20 5 —<br />

60 HF362JW 22 10 15 30 50 10 30 <br />

100 HF363JW 26 15 30 60 75 20 50 <br />

200 HF364JW 53 — 60 125 150 40 50<br />

400 HF365JWA 93 — 125 250 350 50 —<br />

600 HF366JWA 98 — 200 400 500 50 —<br />

3-Pole, 3-Wire Non-Fusible, Type 12 600 Volt AC / 250 Volt DC <br />

30 HNF361JW 14 3 10 20 30 5 —<br />

60 HNF362JW 21 10 20 50 60 10 30 <br />

100 HNF363JW 25 15 40 75 100 20 50 <br />

200 HNF364JW 51 15 60 125 150 40 50<br />

400 HNF365JWA 75 15 125 250 350 50 —<br />

3-Pole, 3-Wire Fusible, Type 4X Stainless Steel 600 Volt AC / 250 Volt DC <br />

30 HF361SW 17 3 7 1 ⁄2 15 20 5 —<br />

60 HF362SW 23 10 15 30 50 10 30 <br />

100 HF363SW 28 15 30 60 75 20 50 <br />

200 HF364SW 55 — 60 125 150 40 50<br />

400 HF365SWA 75 15 125 250 350 50 —<br />

400 HF365SSWA 75 15 125 250 350 50 —<br />

3-Pole, 3-Wire Non-Fusible, Type 4X Stainless Steel 600 Volt AC / 250 Volt DC <br />

30 HNF361SW 15 3 10 20 30 5 —<br />

60 HNF362SW 23 10 20 50 60 10 30 <br />

100 HNF363SW 27 15 40 75 100 20 50 <br />

200 HNF364SW 54 15 60 125 150 40 50<br />

400 HNF365SWA 75 15 125 250 350 50 —<br />

400 HNF365SSWA 75 15 125 250 350 50 —<br />

a 200A switches are also rated 600V DC.<br />

Maximum HP ratings listed apply only when time delay<br />

fuses are used.<br />

Also rated 3S/3R for outdoor use.<br />

All switches are suitable for use as service entrance<br />

equipment. Use outside poles of 3-pole switch for 2-pole<br />

application.<br />

600V DC and 600V DC horsepower rating shown<br />

requires (2) poles to be connected in series.<br />

304 grade stainless steel. For switches with enclosures<br />

constructed from 316 grade stainless steel, see page 4-18.<br />

Product Category HDSS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 4-13


Heavy Duty Safety Switches<br />

Type ECS Elevator Control Switches<br />

Revised on 04/30/19<br />

Catalog Logic<br />

4<br />

SAFETY<br />

SWITCHES<br />

Elevator Control Switches<br />

Application<br />

Siemens Type (ECS) Elevator Control disconnect switches are<br />

designed for single cable or hydraulic elevator application to<br />

interrupt the incoming AC power upon receiving a signal from<br />

the Fire Alarm Control Panel (FACP).<br />

Description<br />

The Elevator Control switch units come completely assembled<br />

for quick installation, eliminating the labor and time needed to<br />

assemble individual components. Therefore, the numbering<br />

system assures that you get all of the correct components,<br />

assembled with the correct ratings, without having to individually<br />

order accessories.<br />

It is easy to meet Code requirements for selective coordination<br />

in a fully fused system. Siemens Type (ECS) Elevator<br />

Control disconnect switches utilize Class J fuses that easily<br />

coordinate with any upstream fuse by simply using a 2:1 lineside<br />

to load-side fuse ratio.<br />

Standards<br />

n UL 98 Enclosed and Dead Front Switch –<br />

Guide 96NK3917, File E182262<br />

Catalog Number System<br />

The following catalog numbering system defines an Elevator<br />

Control Switch construction.<br />

Elevator Control<br />

Switches<br />

Ampere rating<br />

1 = 30 A<br />

2 = 60 A<br />

3 = 100 A<br />

4 = 200 A<br />

5 = 400A<br />

Control Transformer<br />

T2 = 208 V<br />

T3 = 240 V<br />

T1 = 480 V<br />

T4 = 600 V)<br />

Fire Safety Interface Relay<br />

(3PDT, 10 A, 120 V)<br />

R2 = 24 Vdc Coil<br />

R1 = 120 Vac Coil<br />

ECS 1 T2 R2 G F1 3 N B<br />

Pilot Light ON<br />

G = Green<br />

R = Red<br />

W = White<br />

Fire Alarm Voltage Monitoring Relay<br />

(To Monitor Shunt Trip Voltage)<br />

F1 = Single-Pole<br />

F3 = Three-Pole<br />

Enclosure options (NEMA 1 Standard<br />

With No Suffix Designation Required)<br />

3 = NEMA 3R<br />

D = NEMA 12<br />

P = NEMA 4 Painted Steel<br />

Neutral Lug<br />

N = Isolated Full Capacity<br />

Auxiliary Contacts (1NO/1NC)<br />

B = Main Switch<br />

a 100 VA with Primary and Secondary fusing (120 V Secondary)<br />

4-14<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Heavy Duty Safety Switches<br />

Type ECS Elevator Control Switches<br />

Revised on 04/30/19<br />

Features<br />

Elevator Control Switches<br />

Standard Features<br />

n 30-400 A, 600 Vac, 3-phase fused power switch<br />

n 200 kA RMS assembly short-circuit current rating<br />

n Shunt trip 120 V<br />

n Control power terminal block<br />

n Ground lug compliant with the National Electric Code<br />

n Class J fuse mounting only (Class J fuses not included)<br />

n Key to test switch<br />

n Pilot light – "ON"<br />

n Mechanically interlocked auxiliary contact for hydraulic<br />

elevators with battery backup (5 A, 120 Vac rated)<br />

n Handle designed for hook stick operation<br />

Optional Features<br />

n Control power transformer with fuses and blocks<br />

n Fire safety interface relay<br />

n Isolated neutral lug (oversized 200% rated neutral option<br />

available where required by excessive non-linear loads)<br />

n Fire Alarm Voltage Monitoring Relay (to monitor Shunt<br />

Trip Voltage)<br />

n NEMA 3R, 4, and 12 enclosures available<br />

n OSHPD Special Seismic Certification Preapproval (OSP)<br />

Other Options<br />

Optional features include contact closure, i.e. battery lowering/<br />

door opening system. The B option offers support for the<br />

states of Arizona, Oregon, and Texas requirements to prevent<br />

"nuisance" fire alarms by over-riding the "Control Power not<br />

Available" signal when the Siemens Elevator control disconnect<br />

is manually (intentionally) turned off, and distinctive signaling for<br />

ON-OFF-TRIPPED conditions (Option B).<br />

All Siemens Elevator Control elevator disconnect switches<br />

are UL-Listed and designed for safe access by qualified<br />

personnel. When maintenance or shutdown service is<br />

required, no energized parts are exposed inside the enclosure<br />

when the disconnect switch is manually turned to the OFF<br />

position. For proper maintenance safety precautions, always<br />

turn off incoming power to the Siemens Elevator Control<br />

elevator switch when possible. When servicing any live<br />

electrical equipment, always wear appropriate personal<br />

protective equipment.<br />

Shunt-Trip Operation<br />

The disconnect means is a shunt-trip operated switch. The<br />

control power source for the shunt-trip operator is a 120 Vac<br />

supply originating in the Siemens Elevator Control switch.<br />

Current to the shunt-trip device is switched by an isolation<br />

relay, which is in turn controlled by the FACP.<br />

The control signal may be either 24 Vdc from the FACP<br />

(Option R2) or a "dry" contact closure in the FACP (Option R1).<br />

In the case of a “dry” contact closure, the sensing voltage is<br />

120 Vac originating in the Siemens Elevator Control switch.<br />

A key test switch (Option K) is included for testing the<br />

shunttrip circuit.<br />

Supervisory Indication<br />

Additionally, an optional separate relay can be specified to<br />

monitor the 120 Vac control power source in the Siemens<br />

Elevator Control switch. This relay (Option F1 or F3) is used to<br />

provide supervisory indication of "Control Power Available" as<br />

required by NFPA 72 Section 6.15.4.4.<br />

Transformer Fuse Details<br />

ECS Voltage/<br />

Transformer Voltage<br />

Primary Fuse<br />

(amps)<br />

Secondary Fuse<br />

(amps)<br />

208/120 FNQ-R-2 FNM-1 1/4<br />

240/120 FNQ-R-2 FNM-1 1/4<br />

480/120 FNQ-R-1 FNM-1 1/4<br />

600/120 FNQ-R-1 FNM-1 1/4<br />

4 SAFETY<br />

SWITCHES<br />

UL A / NEC B Listed Horsepower Ratings<br />

Voltage / Poles<br />

30A 60A 100A 200A 400A<br />

Std b Max a Std b Max a Std b Max a Std b Max a Std b Max a<br />

208VAC / 3 Pole B 2 5 5 10 10 15 20 40 40 75<br />

240VAC / 3 Pole A 2 7½ 7½ 15 15 30 25 60 50 75<br />

480VAC / 3 Pole A 5 15 15 30 25 60 50 125 100 150<br />

6008VAC / 3 Pole A 7½ 20 15 50 30 75 60 150 125 200<br />

Fuse and Short Circuit Information<br />

This switch is suitable for use with Class J Fuses ONLY.<br />

a Max HP with time delay Class J Fuses.<br />

b Max HP with non-time delay Class J Fuses.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 4-15


Heavy Duty Safety Switches<br />

Type VBII 4 & 6-Pole Heavy Duty Safety Switches<br />

Selection<br />

4<br />

SAFETY<br />

SWITCHES<br />

Application<br />

4 & 6-pole Switches are commonly<br />

used as a disconnecting means for<br />

two-speed, two-winding motors.<br />

Fused switches provide both over<br />

current and short circuit protection.<br />

Non-fusible switches normally provide<br />

a local disconnection means for twospeed<br />

motors which are remote from<br />

their motor controller. 4-pole switches<br />

are also used in 3-phase, 4-wire circuits<br />

when a switching neutral is required.<br />

All 4 & 6-pole switches are service<br />

entrance rated.<br />

Description<br />

4 & 6-pole switches are available in<br />

30-200A ratings and in both fusible and<br />

non-fusible versions. 4-pole switches are<br />

supplied with either Type 1 or Type12/3R<br />

enclosures.<br />

6-pole switches are available with either<br />

Type 12/3R or Type 4X stainless steel<br />

enclosures.<br />

Standards<br />

b UL & CUL listed under file #E4776<br />

b Meets UL98 for enclosed switches<br />

b 4 & 6-Pole switches are suitable for<br />

use as service entrance<br />

b Meets NEMA Standard KS-1 for<br />

enclosed switches<br />

b Meets NEC wire bending space<br />

requirements<br />

Features<br />

b Visible blade, double break switching<br />

action<br />

b Highly visible ON/OFF indication<br />

b Defeatable dual cover interlock<br />

b Padlock option in OFF position<br />

b All copper current carrying parts a<br />

b Tangenital knockouts (Type 1,<br />

4-pole switches)<br />

HNF662J<br />

4-Pole Type VBII Switches ab<br />

Indoor Type 1 Type 12/3R Industrial Horsepower Ratings <br />

Amp Catalog Ship Wt. Catalog Ship Wt. 240V, 2Ø, 4W 240V 3Ø 480V, 3Ø 600V, 3Ø 250V<br />

System Rating Number (lbs.) Number (lbs.) DC<br />

Std. Max. Std. Max. Std. Max. Std. Max.<br />

Fusible 600 Volt AC, 250 Volt DC — 4-Pole, 4 Fuse d<br />

30 HF461 36 HF461J 36 3 10 3 7 1 ⁄2 5 15 7 1 ⁄2 20 5<br />

60 HF462 40 HF462J 40 7 1 ⁄2 20 7 1 ⁄2 15 15 30 15 50 10<br />

100 HF463 43 HF463J 43 15 30 15 30 25 60 30 75 20<br />

200 HF464n 88 HF464Jn 88 25 50 25 60 50 125 60 150 40<br />

Non-fusible 600 Volt AC, 250 Volt DC — 4-Pole<br />

30 HNF461 32 HNF461J 32 — 10 — 10 — 20 — 30 5<br />

60 HNF462 34 HNF462J 34 — 20 — 20 — 50 — 60 10<br />

100 HNF463n 36 HNF463Jn 36 — 30 — 40 — 75 — 100 20<br />

200 HNF464n 78 HNF464Jn 78 — 50 — 60 — 125 — 150 4<br />

6-Pole Type VBII Switches abe<br />

Type 12/3R Industrial Type 4X Stainless Steel Horsepower Ratings c<br />

Amp Catalog Ship Wt. Catalog Ship Wt. 240V 3Ø 480V, 3Ø 600V, 3Ø 250V<br />

System Rating Number (lbs.) Number (lbs.) Std. Max. Std. Max. Std. Max. DC<br />

Fusible 600 Volt AC, 250 Volt DC — 6-Pole, 6 Fuse d<br />

30 HF661J 37 HF661Sn 37 3 7 1 ⁄2 5 15 7 1 ⁄2 20 5<br />

60 HF662J 41 HF662Sn 41 7 1 ⁄2 15 15 30 15 50 10<br />

100 HF663Jn 44 HF663Sn 44 15 30 25 60 30 75 20<br />

200 HF664Jn 90 HF664Sn 90 25 60 50 125 60 150 40<br />

Non-fusible 600 Volt AC, 250 Volt DC — 6-Pole<br />

30 HNF661J 33 HNF661S 33 — 10 — 20 — 30 5<br />

60 HNF662J 35 HNF662S 35 — 20 — 50 — 60 10<br />

100 HNF663J 37 HNF663S 37 — 40 — 75 — 100 20<br />

200 HNF664J 80 HNF664Sn 80 — 60 — 125 — 150 40<br />

n Built to order. Allow 3-5 weeks for delivery.<br />

a Lugs are aluminum alloy as standard. Optional copper<br />

body lugs are available.<br />

b All 4 & 6-pole VBII switches are suitable for use as<br />

service equipment when a neutral is installed or<br />

equipment ground kit is properly connected.<br />

c Dual horsepower ratings: Std. – applies when<br />

non-time-delay fuses are installed. Max. – applies<br />

when time delay fuses are installed.<br />

d Fusible switches accept Class H Fuses as the standard.<br />

Class R & J fuses can also be installed and<br />

increase the rating from 10,000 to 200,000 AIC. For<br />

Class J, the load base is moved upward. For Class R<br />

fuses, rejection kits are required.<br />

e Supplied with factory installed ground lugs.<br />

4-16<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category HDSS


Heavy Duty Safety Switches<br />

Special Application Switches / Interlocked Receptacle Switches<br />

Selection<br />

Application<br />

Receptacle Safety Switches<br />

provide cord connection protection<br />

of heavy-duty portable equipment<br />

(welders, infrared ovens, batch<br />

feeders, portable conveyors, assembly<br />

line fixtures and tools, refrigerator<br />

trucks, etc.) under load or fault<br />

conditions.<br />

Standards<br />

All receptacle switches are UL listed<br />

under file #E4776. Those with a<br />

viewing window are also CSA certified<br />

under file #1079316.<br />

Description ab<br />

Type 12 and 4/4X Receptacle<br />

Safety Switches are available<br />

with 3-phase, 4-wire grounded<br />

type Crouse-Hinds Arkite 2 or<br />

Pyle-National receptacle, pre-wired<br />

and mounted with interlock linkage to<br />

the switch mechanism. Insertion or<br />

removal of the plug is prevented by<br />

the interlock linkage while the switch<br />

is in the “ON” position. Receptacle<br />

prevents operation of switch if<br />

incorrect plug is inserted.<br />

Crouse-Hinds Interlocked Receptacle Switches<br />

Type 12 <br />

Type 4/4X <br />

Shipping Accepts Crouse-Hinds<br />

Ampere Wt. (lbs.) Arktite a Plug<br />

Rating Catalog Number Catalog Number Std. Pkg. Catalog Number<br />

HF362JCH<br />

4 SAFETY<br />

SWITCHES<br />

240V Fusible, 3-Pole, 3-Wire<br />

30 HF321JCH HF321SCHs 23 APJ3485 & NPJ3485<br />

60 HF322JCH HF322SCHs 30 APJ6485 & NPJ6485<br />

100 HF323JCH HF323SCHs 36 APJ10487 & NPJ10487<br />

600V Fusible, 3-Pole, 3-Wire<br />

30 HF361JCH HF361SCH 24 APJ3485 & NPJ3485<br />

60 HF362JCH HF362SCH 30 APJ6485 & NPJ6485<br />

100 HF363JCH HF363SCHs 36 APJ10487 & NPJ10487<br />

600V Non-Fusible, 3-Pole, 3-Wire<br />

30 HNF361JCHs HNF361SCHs 22 APJ3485 & NPJ3485<br />

60 HNF362JCH HNF362SCH 29 APJ6485 & NPJ6485<br />

100 HNF363JCHs HNF363SCHs 35 APJ10487 & NPJ10487<br />

600V Fusible, 3-Pole, 3-Wire with Viewing Window<br />

30 HF361JCHWs HF361SCHWs 24 APJ3485 & NPJ3485<br />

60 HF362JCHW HF362SCHW 30 APJ6485 & NPJ6485<br />

100 HF363JCHWs HF363SCHWs 36 APJ10487 & NPJ10487<br />

600V Non-Fusible, 3-Pole, 3-Wire with Viewing Window<br />

30 HNF361JCHWs HNF361SCHWs 22 APJ3485 & NPJ3485<br />

60 HNF362JCHW HNF362SCHWs 29 APJ6485 & NPJ6485<br />

100 HNF363JCHWs HNF363SCHWs 35 APJ10487 & NPJ10487<br />

Pyle-National Interlocked Receptacle Switches<br />

3-Poles Fusible and Non-Fusible<br />

Type 12<br />

Ampere Rating<br />

Type 12 Stainless Steel Shipping Accepts Pyle-National<br />

Voltage Catalog Catalog Wt. (lbs.) QuelArc bc Plugs<br />

Switch Receptacle Rating Number Number Std. Pkg. Plug Catalog Number<br />

30 30<br />

600 (F) HF361JPNs HF361SPNs 23<br />

600 (N-F) HNF361JPN HNF361SPN 21<br />

JPD-83046<br />

240 (F) HF322JPNs — 28<br />

60 60 600 (F) HF362JPNs HF362SPNs 28 JPD-116046<br />

600 (N-F) HNF362JPN HNF362SPN 27<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

a Arktite is a registered trademark of the Crouse-<br />

Hinds Company. Plugs are not sold or supplied by<br />

Siemens.<br />

Product Category HDSS<br />

b Indicates plug with maximum diameter cable bushing.<br />

c QuelArc is a registered trademark of the Pyle-<br />

National Company.<br />

Ampere rating of both switch and receptacle.<br />

Also rated Type 3R/3S.<br />

Enclosure is constructed of Type 304 stainless steel.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 4-17


Heavy Duty Safety Switches<br />

Special Application Safety Switches / Type VBII Non-Metallic & 316 Grade Stainless Steel<br />

Application<br />

Siemens Non-metallic and 316 grade<br />

stainless steel switches provide a<br />

superior level of corrosion resistance<br />

to assure trouble free performance in<br />

the most severe conditions. 316 grade<br />

stainless steel provides increased<br />

corrosion resistance when compared to<br />

304 grade, especially in atmospheres<br />

containing a high level of chlorine<br />

commonly encountered in marine and<br />

waste management applications. Our<br />

non-metallic enclosures are constructed<br />

from fiberglass reinforced polyester and<br />

are extremely resistant to a wide range<br />

of corrosive atmospheres. They allow a<br />

wide range of operating temperatures<br />

and their insulating properties virtually<br />

eliminate problems caused by internal<br />

condensation.<br />

Description<br />

30-200A, 600V Max, fusible and nonfusible<br />

switches are available in both<br />

non-metallic and 316 grade stainless<br />

steel versions. All are supplied with<br />

factory installed ground bars as<br />

standard. Viewing windows are also<br />

available in the stainless offering.<br />

4<br />

SAFETY<br />

SWITCHES<br />

Type 4/4X Non-Metallic<br />

Ampere<br />

Rating<br />

Catalog<br />

Number<br />

Ship Weight<br />

Std. pkg.<br />

(lbs.)<br />

Horsepower Rating—3-Phase<br />

240 Volt AC 480 Volt AC 600 Volt AC<br />

Std. Max. Std. Max. Std. Max.<br />

250<br />

Volts<br />

DC<br />

600<br />

Volts<br />

DC<br />

3-Pole, 4-Wire, 240 Volt Fusible, Type 4X e<br />

30 HF321NX 21 3 7 1 ⁄2 — — — — 5 —<br />

60 HF322NXs 22 7 1 ⁄2 15 — — — — 10 —<br />

3-Pole, 4-Wire, 600 Volt AC Fusible, Type 4X bce<br />

30 HF361NX 21 3 7 1 ⁄2 5 15 7 1 ⁄2 20 5 15 d<br />

60 HF362NX 22 7 1 ⁄2 15 15 30 15 50 10 30 d<br />

100 HF363NXs a 39 15 30 25 60 30 75 20 50 d<br />

200 HF364NXs a 83 25 60 50 125 60 150 40 50<br />

3-Pole, 3-Wire, 600 AC Volt Non-Fusible, a Type 4X bc<br />

30 HNF361X 20 — 7 1 ⁄2 — 20 — 30 5 15 d<br />

60 HNF362X 20 — 15 — 50 — 60 10 30 d<br />

100 HNF363Xs 38 — 30 — 75 — 100 20 50 d<br />

200 HNF364Xs 81 — 60 — 125 — 150 40 50<br />

Type 4/4X 316 Grade Stainless Steel<br />

Ampere<br />

Rating<br />

Standard<br />

Catalog<br />

Number<br />

With Viewing<br />

Window<br />

Catalog<br />

Number<br />

Ship<br />

Weight<br />

(lbs.)<br />

Horsepower Rating—3-Phase<br />

240 Volt AC 480 Volt AC 600 Volt AC<br />

Std. Max. Std. Max. Std. Max.<br />

250<br />

Volts<br />

DC<br />

600<br />

Volts<br />

DC<br />

240V AC, 250V DC Fusible 3-Pole, 3-Wire<br />

30 HF321SSs — 15 3 7 1 ⁄2 — — — — 5 —<br />

60 HF322SSs — 19 7 1 ⁄2 15 — — — — 10 —<br />

100 HF323SSs — 27 15 30 — — — — 20 —<br />

200 HF324SSs — 48 25 60 — — — — 40 —<br />

600V AC, 250V DC Fusible 3-Pole, 3-Wire c<br />

30 HF361SS HF361SSW 17 3 7 1 ⁄2 5 15 7 1 ⁄2 20 5 —<br />

60 HF362SS HF362SSW▲ 21 7 1 ⁄2 15 10 30 15 50 10 30 d<br />

100 HF363SS HF363SSWs 28 15 30 25 60 30 75 20 50 d<br />

200 HF364SS HF364SSWs 54 25 60 50 125 60 150 40 50<br />

600V AC, 250 V DC Non-Fusible 3-Pole, 3-Wire ac<br />

30 HNF361SS HNF361SSW 15 — 10 — 20 — 30 5 —<br />

60 HNF362SS HNF362SSWs 21 — 20 — 50 — 60 10 30 d<br />

100 HNF363SS HNF363SSWs 26 — 40 — 75 — 100 20 50 d<br />

200 HNF364SS HNF364SSWs 51 — 60 — 125 — 150 40 50<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

a Also used for 240 volt applications.<br />

b Add “L” to end of catalog number for switches less<br />

line & load lugs with mounting hardware for crimp<br />

type or copper body lugs.<br />

c 200A switches are also rated 600V DC max.<br />

d 600V DC voltage and horsepower rating shown<br />

requires (2) poles to be connected in series.<br />

e Supplied with factory installed neutral.<br />

4-18<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category HDSS


Heavy Duty Safety Switches<br />

Enclosed Solar Photovoltaic (PV) Switches<br />

Revised on 04/30/19<br />

Selection<br />

Application<br />

Solar disconnect switches are<br />

designed to be used in the DC portion<br />

of photovoltaic power generation<br />

circuits. They incorporate powerful<br />

magnets within the switch line base<br />

which work in combination with a<br />

double break switching action to<br />

quickly dissipate the very hot arc that<br />

is generated when a 600V DC circuit<br />

is opened under load. These circuits<br />

are defined by article 690 of the NEC<br />

which requires the grounded conductor<br />

to be at ground potential at all times<br />

and therefore cannot be switched.<br />

Description<br />

30-200A switches are available in<br />

both Type 1 and 3R enclosures and in<br />

both fusible and non–fusible versions.<br />

They are provided with an additional<br />

door mounted warning label as<br />

required by the NEC and are supplied<br />

with a factory installed equipment<br />

ground bar. They are built to UL98<br />

requirements but are UL listed in file<br />

number E335018 as UL1741 photovoltaic<br />

disconnect switches. They are<br />

3 pole switches that are approved to<br />

switch 3 separate 600V DC circuits<br />

(one per pole). The design incorporates<br />

many of the standard VBII switch<br />

features including a rolled out enclosure<br />

front flange, a large metal operating<br />

handle, oversized line and load lugs<br />

and large wire gutters. 1000VDC<br />

photovoltaic switches are UL98B listed<br />

for solar applications and comply with<br />

article 690 of the NEC. The new<br />

400-600Amp switches are also UL98B<br />

listed at 600VDC and come in NEMA<br />

Type 3R.<br />

Solar Photovoltaic Enclosed Disconnect Switches<br />

Ampere<br />

Rating<br />

Indoor – Type 1 Outdoor – Type 3R Rated Isc<br />

Catalog Number<br />

Ship Wt*<br />

Std. Pkg. Catalog Number<br />

Ship Wt*<br />

Std. Pkg.<br />

Per NEC<br />

Article 690<br />

Negative Ground 3 Pole 3 Wire Fusible 600Volt DC<br />

30 HF361PV 14 HF361RPV 15 19.2 A<br />

60 HF362PV 20 HF362RPV 21 38.4 A<br />

100 HF363PV▲ 25 HF363RPV 26 64.0 A<br />

200 HF364PV▲ 49 HF364RPV 50 128.0 A<br />

Negative Ground 3 Pole 3 Wire Non-Fusible 600Volt DC<br />

30 HNF361PV 12 HNF361RPV 13 24.0 A<br />

60 HNF362PV 19 HNF362RPV 20 48.0 A<br />

100 HNF363PV▲ 24 HNF363RPV 25 80.0 A<br />

200 HNF364PV▲ 47 HNF364RPV 48 160.0 A<br />

Positive and Negative Ground, 1 Pole, Fusible 1000 Volt DC<br />

200 HF1104NPV▲ 52 HF1104NRPV▲ 53 128.0A<br />

Positive and Negative Ground, 1 Pole, Non-Fusible 1000 Volt DC<br />

200 HNF1104NPV▲ 50 HNF1104NRPV▲ 51 160.0A<br />

Positive Ground 3 Pole 3 Wire Fusible 600Volt DC<br />

30 HF361PVPG 14 HF361RPVPG 15 19.2 A<br />

60 HF362PVPG▲ 20 HF362RPVPG 21 38.4 A<br />

100 HF363PVPG▲ 25 HF363RPVPG▲ 26 64.0 A<br />

200 HF364PVPG▲ 49 HF364RPVPG▲ 50 128.0 A<br />

Positive Ground 3 Pole 3 Wire Non-Fusible 600Volt DC<br />

30 HNF361PVPG 12 HNF361RPVPG 13 24.0 A<br />

60 HNF362PVPG▲ 19 HNF362RPVPG 20 48.0 A<br />

100 HNF363PVPG▲ 24 HNF363RPVPG▲ 25 80.0 A<br />

200 HNF364PVPG▲ 47 HNF364RPVPG▲ 48 160.0 A<br />

Positive and Negative Ground, 2 Wire, 600Volt DC, Type 3R<br />

Amperage<br />

Rating<br />

No.<br />

Poles Fuse Type Catalog Number<br />

Ship Wt*<br />

Std. Pkg<br />

400A 1 Fusible HF165NRPV▲ 165 256A<br />

400A 1 Non-fusible HNF165NRPV▲ 127 256A<br />

600A 1 Fusible HF166NRPV▲ 167 384A<br />

600A 1 Non-fusible HNF166NRPV▲ 129 384A<br />

Rated Isc Per<br />

NEC Article 690<br />

HF361PV<br />

HNF361RPV<br />

4 SAFETY<br />

SWITCHES<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

* In pounds (lbs)<br />

Note: All disconnects are rated at 10,000 AIC per UL<br />

requirements when used with or protected by Class K, J<br />

or R fuses rated at 600VDC.<br />

HF362RPV<br />

Product Category HDSS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 4-19


General and Heavy Duty Safety Switches<br />

Accessories<br />

Revised on 07/31/19<br />

Selection<br />

HR612<br />

HT63<br />

HN264<br />

4<br />

SAFETY<br />

SWITCHES<br />

Class R Fuse Clip Kits<br />

All General Duty and Heavy Duty<br />

Switches are field convertible to accept<br />

Class R Fuse Clip Kits. The kits prevent<br />

the installation of Class H and K fuses<br />

(one kit required per 3-pole switch).<br />

Class R Fuse Clip Kits<br />

Catalog<br />

Number<br />

HR21A<br />

HR21<br />

HR612<br />

HR22A<br />

HR62<br />

HR63<br />

HR64<br />

HR65A<br />

HR66A<br />

Class J Fusing<br />

All 30-600A, 600V and 100-600A,240V<br />

fusible Heavy Duty Switches are field<br />

convertible to accept Class J fuses by<br />

moving the load base to a pre-drilled J<br />

fuse position. All 100-600A, 240V<br />

fusible General Duty switches can also<br />

be field converted to accept Class J fuses.<br />

Class J Fuse Kits<br />

Catalog<br />

Number<br />

HJ66A<br />

Internal Shield Kits (for fusible switches)<br />

Kits provide a clear plastic inner door to<br />

prevent accidental contact with live parts.<br />

Test probe holes are provided and fuses<br />

can be replaced without removal of kit.<br />

Internal Shield Kits b<br />

Switch<br />

Ampere Rating<br />

30A HD<br />

60A HD<br />

100A HD<br />

200A HD<br />

Description<br />

30A, 240V Kit (GD only)<br />

30A, 240V Kit (HD only)<br />

30A, 600V Kit<br />

60A 240V Kit (GD only)<br />

60A, 600V Kit<br />

100A Kit<br />

200A Kit<br />

400A Kit<br />

600A Kit<br />

Description<br />

600A, 240V/600V Kit<br />

Kit Catalog Number<br />

HSK61SSW<br />

HSK62SSW<br />

HSK63SSW<br />

HSK64SSW<br />

Class T Fuse Adapter Kits<br />

All 100-600A, General Duty and 100-<br />

200Amp and 1200Amp Heavy Duty<br />

Switches are field convertible to accept<br />

Class T fuses.<br />

Class T Fuse Adapter Kits a<br />

Catalog<br />

Number<br />

HT23<br />

HT63<br />

HT24<br />

HT64s<br />

HT25A<br />

HT65A<br />

HT26A<br />

HT66A<br />

TFAK72<br />

TFAK75<br />

TFAK82<br />

HN612<br />

Description<br />

100A, 240V Kit<br />

100A, 600V Kit<br />

200A, 240V Kit<br />

200A, 600V Kit<br />

400A, 240V Kit<br />

400A, 600V Kit<br />

600A, 240V Kit<br />

600A, 600V Kit<br />

800A, 240V Kit<br />

800A, 600V Kit<br />

1200A, 240V Kit<br />

Neutral Kits<br />

Standard Neutral Kits can be field<br />

installed in General and Heavy Duty<br />

Switches.<br />

Neutral Kits<br />

Switch Ampere Rating Kit Catalog Number<br />

30 GD n/a<br />

30 HD HN612<br />

60 GD HN22A<br />

60, 100 HD, 100 GD HN623<br />

200 HN64<br />

400 & 600 HN656A<br />

800 & 1200 HN678<br />

200% Neutral Kits<br />

UL listed 200% Neutrals are available<br />

on 100-600A Heavy Duty Switches.<br />

They are typically used with non-linear<br />

transformers or where increased neutral<br />

ampacity/lug capacity is required.<br />

200% Neutral Kits<br />

Switch<br />

Ampere<br />

Rating<br />

HP61<br />

Kit<br />

Catalog<br />

Number<br />

Fuse Puller Kits<br />

Fuse Puller Kits are field installable in<br />

30-100A Type VBII Heavy Duty Switches<br />

(one kit required per 3-pole switch).<br />

Fuse Puller Kits<br />

Wire Range Line &<br />

Load Lugs (Cu/Al)<br />

100 HN263 (2) #14-1/0 AWG<br />

200 HN264 (2) #6 AWG-300 Kcmil<br />

400 HN656A<br />

(2) 1/0 AWG-600 Kcmil<br />

(2) #6 AWG-300 Kcmil<br />

600 HN678A<br />

(2) 1/0 AWG-600 Kcmil<br />

(2) #6 AWG-300 Kcmil<br />

Switch<br />

Ampere<br />

Fuse Puller Kit<br />

Rating<br />

Catalog Number<br />

030 HP61<br />

060 HP62s<br />

100 HP63s<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

a One kit per pole required.<br />

b Not designed for use in Non-metallic 4X safety<br />

switches. Not designed for use with Auxiliary Contacts.<br />

4-20<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category HDSS


General and Heavy Duty Safety Switches<br />

Accessories<br />

Revised on 03/31/20<br />

Selection<br />

HA261234<br />

HA265678<br />

HLC612<br />

HG261234<br />

Auxiliary Contacts<br />

Auxiliary Contacts are available only for Heavy Duty Switches.<br />

The auxiliary contacts are available in 1 normally open and<br />

1 normally closed or 2 normally open and 2 normally closed<br />

configurations. Siemens offers a PLC Auxiliary Switch (30-<br />

600A) that has very low resistance for low voltage and current<br />

typical in PLC circuits. All auxiliary contacts make after and<br />

break before main switch contacts.<br />

Auxiliary Contacts a<br />

Switch<br />

Ampere<br />

Aux. Switch<br />

Catalog<br />

Number<br />

Kit Ampere<br />

Rating<br />

125V<br />

AC<br />

Max.<br />

250V<br />

AC<br />

Max.<br />

28V<br />

DC<br />

Max.<br />

Copper Lug Kits<br />

Heavy duty switches are UL approved to accept<br />

field installed copper lug kits.<br />

Horsepower<br />

Rating<br />

125V<br />

AC<br />

Max.<br />

250V<br />

AC<br />

Max.<br />

With 1 NO & 1 NC Isolated Contacts<br />

30-600 HA161234 10 10 7 1/2 3/4<br />

800-1200 HA165678 10 10 — 1/2 3/4<br />

With 2 NO & 2 NC Isolated Contacts<br />

30-600 HA261234 10 10 7 1/2 3/4<br />

800-1200 HA265678 10 10 7 1/2 3/4<br />

Low Current PLC Type with 1 NO &<br />

1 NC Gold Plated Contacts<br />

30-600 HA361234 10 10 7 1/2 3/4<br />

800-1200 HA365678 10 10 — 1/2 3/4<br />

Copper Lug Kits<br />

Switch<br />

Ampere<br />

Rating<br />

Copper Lug<br />

Catalog<br />

Number<br />

Description<br />

30–60 HLC612 (9) Lugs/Kit #14-4 AWG Cu<br />

100 HLC63s (9) Lugs/Kit #14-1/0 AWG Cu<br />

200 HLC64s (9) Lugs/Kit #6 AWG-300 Kcmil Cu<br />

400-600 HCU656An (1) Lugs/Kit #1/0 AWG-600 Kcmil Cu<br />

800–1200 HLC65678 (1) Lugs/Kit #1/0 AWG-600 Kcmil Cu<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

n Purchase field replacement kit along with lugs.<br />

a Series A 400A and 600A switches use HA161234, HA261234 or HA361234 auxiliary<br />

contacts. Earlier 400A and 600A switches use HA165678, HA265678 or HA365678<br />

auxiliary contacts.<br />

Quick Connects<br />

They provide two point control power take-off capability and<br />

are normally used on two poles on the line side when it is<br />

required to have control power available when the switch is<br />

in the OFF position. They provide a mounting provision for<br />

standard ¼” quick connect terminal. Installed in the line or<br />

load side. 30A VBII switches have lugs UL listed to accept (2)<br />

wires per pole as standard so a 30A kit is not required.<br />

Quick Connects<br />

Catalog Number<br />

HCQ62<br />

HCQ63<br />

HCQ64<br />

Isolated Ground Kits<br />

Isolated Ground Kits are available on 30-600A Heavy Duty<br />

Switches. They are normally used on circuits with a high content<br />

of computer or other electronic loading which require a ground<br />

which is isolated from the building ground and neutral circuits. The<br />

kit includes both isolated and grounded terminals as listed below.<br />

Isolated Ground Kits<br />

Switch<br />

Ampere<br />

Rating<br />

Catalog Number of Terminals<br />

Number Isolated Grounded<br />

30–200 HG261234 2 2 #14-4 AWG<br />

400–600 HG2656A 4 4<br />

Equipment Ground Kits<br />

Switch<br />

Ampere<br />

Rating<br />

Catalog<br />

Number<br />

Description<br />

60A 2 wire quick connect kit<br />

100A 2 wire quick connect kit<br />

200A 2 wire quick connect kit<br />

Number of<br />

Terminals<br />

Wire Range<br />

Per Terminal (Cu/Al)<br />

2/0-14 AWG<br />

2/0-6 AWG<br />

Equipment Ground Kits<br />

Equipment Ground Lug Kits are available for all General and<br />

Heavy Duty Switches. They are field installable in Type 1<br />

and Type 3R Switches and are factory installed as standard<br />

in Type 4 / 4X and Type 12 and also in all VBII 4&6-pole<br />

Switches.<br />

Wire Range<br />

Per Terminal (Cu/Al)<br />

30–200 GD HG61234 2 #14-4 AWG<br />

30–200 HD HG61234 2 #14-4 AWG<br />

400 & 600 HG656A 4 2/0-6 AWG<br />

800–1200 HG678 8 #6 AWG-250 Kcmil<br />

4 SAFETY<br />

SWITCHES<br />

Product Category HDSS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 4-21


General and Heavy Duty Safety Switches<br />

Hub and Lug Data<br />

Revised on 10/31/19<br />

Selection<br />

4<br />

SAFETY<br />

SWITCHES<br />

Interchangeable Hubs<br />

Conduit hubs are available for Type 3R,<br />

12 and 4 / 4X applications. 30-200A<br />

Type 3R Switches are provided with a<br />

conduit hub provision and a removable<br />

hub plate on their top rainshed.<br />

Conduit<br />

Size<br />

(inches)<br />

Type 3R a<br />

Catalog<br />

Number<br />

Cover ECHA000<br />

3/4 ECHA075<br />

1 ECHA100<br />

1 1/4 ECHA125<br />

Cover ECHS000<br />

3/4 ECHS075<br />

1 ECHS100<br />

1 1/4 ECHS125<br />

1 1/2 ECHS150<br />

2 ECHS200<br />

2 1/2 ECHS250<br />

2 1/2 ECHV250<br />

3 ECHV300<br />

3 1/2 ECHV350<br />

4 ECHV400<br />

Type 4/4X b<br />

3/4 SSH075<br />

1 SSH100<br />

1 1/4 SSH125<br />

1 1/2 SSH150<br />

2 SSH200<br />

2 1/2 SSH250<br />

3 SSH300<br />

3 1/2 SSH350<br />

4 SSH400<br />

Used On<br />

30–60A GD Only<br />

100–200A GD<br />

30–200A HD<br />

400–1200A<br />

30–200A<br />

400–600A<br />

Note: 30 thru 200A. Type 3R Switches have<br />

removable hub plates on rainshed. 400A and<br />

larger Type 3R Switches have no provisions for<br />

mounting hubs. Drill or punch hole in the field to<br />

accommodate hub size desired.<br />

Field Replacement Kits and<br />

Neutral Barrier Kits<br />

All Heavy Duty Switches are field<br />

convertible for (Crimp) type lugs.<br />

When compression lugs are required for<br />

30-100A switches, a neutral barrier kit<br />

is required for 1-Phase, 3W or 3-Phase,<br />

4W applications. When compression<br />

lugs are required on 400-1200A switches,<br />

lug mounting kits are required.<br />

Field Replacement Kits and<br />

Neutral Barrier Kits<br />

Switch<br />

Ampere<br />

Rating<br />

Catalog<br />

Number<br />

Kit Description<br />

30 HCL612 Neutral Barrier Kit<br />

60 &<br />

100<br />

HCL623 Neutral Barrier Kit<br />

400 HCM65A 240V/600V Fusible Kit<br />

400 HNCM65A<br />

240/600V Non-<br />

Fusible Kit<br />

600 HCM66A 240V/600V Fusible Kit<br />

600 HNCM66A<br />

240V/600V Non-<br />

Fusible Kit<br />

800 &<br />

1200 e HCL65678n<br />

1 Pole, Compression<br />

Lug Mounting Kit<br />

Lugs<br />

30 & 60A HD Switches are suitable<br />

for use with 60° or 75°C wire. 100-<br />

1200A are suitable for use with 75°C<br />

rated wire.<br />

Multiple Padlock Accessory<br />

A tamper-proof device to provide for<br />

multiple padlocking to meet OSHA or<br />

plant requirements. Accepts up to 6<br />

1/4” padlocks. Catalog number SL0420.<br />

Standard Carton-12.<br />

SSH125<br />

ECHV300<br />

ECHS200<br />

Wire Ranges (Line, Load and Standard Neutral)<br />

Switch<br />

Ampere<br />

Rating<br />

Wire Range with<br />

Wire Bending Space<br />

Per NEC Requirements<br />

Lug Wire Range<br />

30GD #14-8 AWG (Cu/AI) #14-2 AWG (Cu/Al) f<br />

60GD #14-6 AWG (Cu) #14-2 AWG (Cu) f<br />

30HD #14-6 AWG (Cu/AI) #14-2 AWG (Cu/Al)<br />

60HD hj #14-3 AWG (Cu/AI) #14-2 AWG (Cu/Al)<br />

100 k #14-1/0 AWG (Cu/Al) #14-1/0 AWG (Cu/Al)<br />

200 i #6 AWG-250 Kcmil (Cu/Al) #6 AWG-300 Kcmil (Cu/Al)<br />

400 g (1) 1/0 AWG-600 Kcmil (Cu/Al)<br />

(2) 1/0 AWG-500 Kcmil (Cu/Al)<br />

(2) 1/0 AWG-600 Kcmil (Cu/Al)<br />

600 g (1) 1/0 AWG-600 Kcmil (Cu/Al)<br />

(2) 1/0 AWG-500 Kcmil (Cu/Al)<br />

(2) 1/0 AWG-600 Kcmil (Cu/Al)<br />

800<br />

1200<br />

(3) 1/0 AWG-750 Kcmil (Cu/Al) Line Load<br />

(4) 1/0 AWG-750 Kcmil (Cu/Al) neutral<br />

(4) 3/0 AWG-750 Kcmil (Cu/Al) Line Load<br />

(4) 1/0 AWG-750 Kcmil (Cu/Al) neutral<br />

(3) 1/0 AWG-750 Kcmil (Cu/Al) Line Load<br />

(4) 1/0 AWG-750 Kcmil (Cu/Al) neutral<br />

(4) 1/0 AWG-750 Kcmil (Cu/Al) Line Load<br />

(4) 1/0 AWG-750 Kcmil (Cu/Al) neutral<br />

SL0420<br />

n Built to order. Allow 3-4 weeks for delivery.<br />

a Hubs suitable for 3R Switches.<br />

b Also suitable for Type 12 applications.<br />

c Neutral Barrier kits are required on 30-100A switches<br />

only and only with 1-Phase / 3W or 3-Phase / 4W<br />

loads. Compression Lugs mounting kits are required<br />

on 400-1200A switches only.<br />

d Provides mounting for a single line or load lug.<br />

e Provides mounting for (2) compression lugs per phase<br />

on line or load.<br />

f Neutral lugs (only) are UL approved to accept #14-4<br />

CU/Al cable.<br />

g Max. wire size for height reduced switches is 500 kcmil<br />

(Cu/Al).<br />

h Compact HD NF switches are also UL approved for<br />

#2 Cu/Al conductors.<br />

i All 200A Heavy Duty Switches have a wire range<br />

& wire bending space for (1) #6-300 Kcmil (Cu/Al).<br />

j Also for 30A oversized heavy duty switches.<br />

k Also for 60A oversized heavy duty switches.<br />

4-22<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category HDSS & RESI


General and Heavy Duty Safety Switches<br />

Revised on 09/30/19<br />

Dimensions<br />

Safety Switch Dimensions (Inches)* & Shipping Weights<br />

Catalog Number<br />

Height Width Depth<br />

Box<br />

A<br />

With<br />

Door<br />

B<br />

With<br />

Rain Shed<br />

C<br />

Box<br />

D<br />

With<br />

Handle<br />

E<br />

Box<br />

F<br />

With<br />

Handle<br />

G<br />

Knockout<br />

Diagram <br />

Shipping<br />

Weight<br />

(lbs.)<br />

GF221NA 8.4 8.56 — 5.08 5.44 2.93 3.96 S4 30(10)<br />

GF221NRA 8.4 8.56 8.56 5.08 5.44 2.93 3.96 S5 30(10)<br />

GF222NA 9.91 10.07 — 6.06 6.42 3.21 4.24 S21 20(5)<br />

GF222NRA 9.91 10.07 10.07 6.06 6.42 3.21 4.24 S22 20(5)<br />

GF223N 21.95 23.15 — 9.64 11.7 5.05 8.63 S10 23<br />

GF223NR 21.95 — 23.46 9.64 11.67 5.05 8.7 S11 24<br />

GF224N 29.9 31.07 — 14.62 16.68 6.36 10.92 S12 47<br />

GF224NR 29.9 — 31.42 14.61 16.68 6.36 10.92 S13 48<br />

GF225NA 45.32 45.81 — 22.4 23.404 6.94 9.93 S18 91.1<br />

GF225NRA 45.32 45.81 — 22.4 23.404 6.94 9.93 S19 91.1<br />

GF226NA 45.32 45.81 — 22.4 23.404 6.94 9.93 S18 95.6<br />

GF226NRA 45.32 45.81 — 22.4 23.404 6.94 9.93 S19 95.6<br />

GF321NA 8.4 8.56 — 5.08 5.44 2.93 3.96 S4 30(10)<br />

GF321NRA 8.4 8.56 8.56 5.08 5.44 2.93 3.96 S5 30(10)<br />

GF322NA 9.91 10.07 — 6.06 6.42 3.21 4.24 S21 20(5)<br />

GF322NRA 9.91 10.07 10.07 6.06 6.42 3.21 4.24 S22 20(5)<br />

GF323N 21.95 23.15 — 9.64 11.7 5.05 8.63 S10 25<br />

GF323NR 21.95 — 23.46 9.64 11.67 5.05 8.7 S11 25<br />

GF324N 29.9 31.07 — 14.62 16.68 6.36 10.92 S12 49<br />

GF324NR 29.9 — 31.42 14.61 16.68 6.36 10.92 S13 50<br />

GF325NA 45.32 45.81 — 22.4 23.404 6.94 9.93 S18 94.6<br />

GF325NRA 45.32 45.81 — 22.4 23.404 6.94 9.93 S19 94.6<br />

GF326NRA 45.32 45.81 — 22.4 23.404 6.94 9.93 S19 99.6<br />

GF326NA 45.32 45.81 — 22.4 23.404 6.94 9.93 S18 99.6<br />

GF326NRA 45.32 45.81 — 22.4 23.404 6.94 9.93 S19 99.6<br />

GNF221A 6.18 6.35 — 4.2 4.56 2.88 3.93 S4 20(10)<br />

GNF221RA 6.18 6.35 6.35 4.2 4.56 2.88 3.93 S5 20(10)<br />

GNF321LA 8.4 8.56 — 5.08 5.43 2.93 3.95 S4 30(10)<br />

GNF321RLA 8.4 8.56 8.56 5.08 5.43 2.93 3.95 S5 30(10)<br />

GNF222A 8.4 8.56 — 5.08 5.43 2.93 3.95 S4 30(10)<br />

LNF222RA 8.4 8.56 8.56 5.08 5.43 2.93 3.95 S20 30(10)<br />

GNF222RA 8.4 8.56 8.56 5.08 5.43 2.93 3.95 S5 30(10)<br />

GNF321A 6.18 6.35 — 4.2 4.56 2.88 3.93 S4 20(10)<br />

GNF321RA 6.18 6.35 6.35 4.2 4.56 2.88 3.93 S5 20(10)<br />

GNF322A 8.4 8.56 — 5.08 5.43 2.93 3.95 S4 30(10)<br />

GNF322RA 8.4 8.56 8.56 5.08 5.43 2.93 3.95 S5 30(10)<br />

GNF323 21.95 23.15 — 9.64 11.7 5.05 8.63 S10 23<br />

GNF323R 21.95 — 23.46 9.64 11.67 5.05 8.7 S11 24<br />

GNF324 29.9 31.07 — 14.62 16.68 6.36 10.92 S12 46<br />

GNF324R 29.9 — 31.42 14.61 16.68 6.36 10.92 S13 47<br />

GNF325A 33.47 33.96 — 22.4 23.404 6.94 9.93 S18 75<br />

GNF326A 33.47 33.96 — 22.4 23.404 6.94 9.93 S18 77<br />

HF221J also HF261J 14.27 17.33 — 6.65 9.02 5.32 10.46 — 13<br />

HF221N also HF261 14.26 15.45 — 6.64 9.01 5.05 10.17 S6 12<br />

HF221NR also HF261R 14.39 — 15.77 6.64 9.01 5.05 10.17 S8 13<br />

HF221S also HF261S 14.27 17.33 — 6.65 9.02 5.32 10.46 — 13<br />

HF222J also HF262J 16.22 19.31 — 9.17 11.47 5.33 10.46 — 19<br />

HF222N also HF262 16.26 17.46 — 9.15 11.53 5.05 10.17 S16 18<br />

HF222NR also HF262R 16.26 — 17.77 9.16 11.53 5.05 10.17 S17 19<br />

HF222S also HF262S 16.22 19.31 — 9.17 11.47 5.33 10.46 — 19<br />

HF223J also HF263J 21.96 23.16 — 9.65 12.02 5.34 10.46 — 24<br />

HF223N also HF263 21.95 23.15 — 9.64 12.01 5.05 10.17 S10 23<br />

HF223NR also HF263R 21.95 — 23.46 9.64 11.97 5.05 10.17 S11 24<br />

4 SAFETY<br />

SWITCHES<br />

*For inches / millimeters conversion, multiply inches<br />

by 25.4.<br />

a Knocks not provided on Type 4 / 4X and 12 or in 800 &<br />

1200A switches.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 4-23


General and Heavy Duty Safety Switches<br />

Dimensions<br />

Safety Switch Dimensions (Inches)* & Shipping Weights<br />

4<br />

SAFETY<br />

SWITCHES<br />

Catalog Number<br />

Height Width Depth<br />

Box<br />

A<br />

With<br />

Door<br />

B<br />

With<br />

Rain Shed<br />

C<br />

Box<br />

D<br />

With<br />

Handle<br />

E<br />

Box<br />

F<br />

With<br />

Handle<br />

G<br />

Knockout<br />

Diagram <br />

Shipping<br />

Weight<br />

(lbs.)<br />

HF223S also HF263S 21.96 23.16 — 9.65 12.02 5.34 10.46 — 24<br />

HF224J 29.96 31.07 — 14.62 16.95 6.63 12.58 — 48<br />

HF224N 29.9 31.07 — 14.62 16.98 6.36 12.33 S12 47<br />

HF224NR 29.9 — 31.42 14.61 16.99 6.36 12.33 S13 48<br />

HF224S 29.96 31.07 — 14.62 16.95 6.63 12.58 — 48<br />

HF225NRA 45.32 45.81 — 22.4 23.404 6.94 9.93 S19 91.1<br />

HF225NA 45.32 45.81 — 22.4 23.404 6.94 9.93 S18 91.1<br />

HF226NA 45.32 45.81 — 22.4 23.404 6.94 9.93 S18 95.6<br />

HF226NRA 45.32 45.81 — 22.4 23.404 6.94 9.93 S19 95.6<br />

HF227N 66.67 67.16 — 38.4 39.96 9.24 14.68 — 360<br />

HF227NR 66.67 — 67.74 38.4 39.96 9.24 14.68 — 362<br />

HF228N 66.67 67.16 — 38.4 39.96 9.24 14.68 — 362<br />

HF228NR 66.67 — 67.74 38.4 39.96 9.24 14.68 — 364<br />

HF365A 45.32 45.81 — 22.4 23.404 6.94 9.93 S18 93<br />

HF365JA 45.32 45.81 — 22.4 23.404 6.97 10.05 — 93<br />

HF365RA 45.32 45.81 — 22.4 23.404 6.94 9.93 S19 93<br />

HF365SA 45.32 45.81 — 22.4 23.404 7.34 10.347 — 93<br />

HF365SSA 45.32 45.81 — 22.4 23.404 7.34 10.347 — 93<br />

HF366A 45.32 45.81 — 22.4 23.404 6.94 9.93 S18 98<br />

HF366JA 45.32 45.81 — 22.4 23.404 6.97 10.05 — 98<br />

HF366RA 45.32 45.81 — 22.4 23.404 6.94 9.93 S19 98<br />

HF366SA 45.32 45.81 — 22.4 23.404 7.34 10.347 — 98<br />

HF366SSA 45.32 45.81 — 22.4 23.404 7.34 10.347 — 98<br />

HF321J 14.27 17.33 — 6.65 9.02 5.32 10.46 — 14<br />

HF321N 14.26 15.45 — 6.64 9.01 5.05 10.17 S6 14<br />

HF321NR 14.39 — 15.77 6.64 9.01 5.05 10.17 S8 15<br />

HF321S, SS 14.27 17.33 — 6.65 9.02 5.32 10.46 — 14<br />

HF322J 16.27 19.31 — 9.17 11.47 5.33 10.46 — 20<br />

HF322N 16.26 17.46 — 9.15 11.53 5.05 10.17 S16 19<br />

HF322NR 16.26 — 17.77 9.16 11.53 5.05 10.17 S17 20<br />

HF322S, SS 16.27 19.31 — 9.17 11.47 5.33 10.46 — 20<br />

HF323J 21.96 23.16 — 9.65 12.02 5.34 10.46 — 25<br />

HF323N 21.95 23.15 — 9.64 12.01 5.05 10.17 S10 25<br />

HF323NR 21.95 — 23.46 9.64 11.97 5.05 10.17 S11 26<br />

HF323S, SS 21.96 23.16 — 9.65 12.02 5.34 10.46 — 25<br />

HF324J 29.96 31.07 — 14.62 16.95 6.63 12.58 — 49<br />

HF324N 29.9 31.07 — 14.62 16.98 6.36 12.33 S12 49<br />

HF324NR 29.9 — 31.42 14.61 16.99 6.36 12.33 S13 50<br />

HF324S, SS 21.96 31.07 — 14.62 16.95 6.63 12.58 — 49<br />

HF325JA 45.32 45.81 — 22.4 23.404 6.97 10.05 — 93<br />

HF325NA 45.32 45.81 — 22.4 23.404 6.94 9.93 S18 94.6<br />

HF325NRA 45.32 45.81 — 22.4 23.404 6.94 9.93 S19 94.6<br />

HF325SA 45.32 45.81 — 22.4 23.404 7.34 10.347 — 93<br />

HF325SSA 45.32 45.81 — 22.4 23.404 7.34 10.347 — 93<br />

HF326JA 45.32 45.81 — 22.4 23.404 6.97 10.05 — 98<br />

HF326NA 45.32 45.81 — 22.4 23.404 6.94 9.93 S18 99.6<br />

HF326NRA 45.32 45.81 — 22.4 23.404 6.94 9.93 S19 99.6<br />

HF326SA 45.32 45.81 — 22.4 23.404 7.34 10.347 — 98<br />

HF326SSA 45.32 45.81 — 22.4 23.404 7.34 10.347 — 98<br />

HF327J 66.67 67.16 — 38.4 39.96 9.24 14.68 — 367<br />

HF327N 66.67 67.16 — 38.4 39.96 9.24 14.68 — 380<br />

HF327NR 66.67 — 67.74 38.4 40.25 9.24 14.68 — 383<br />

HF327S 66.67 67.16 — 38.4 39.96 9.24 14.68 — 367<br />

HF328N 66.67 67.16 — 38.4 39.96 9.24 14.68 — 382<br />

HF328NR 66.67 — 67.74 38.4 40.25 9.24 14.68 — 385<br />

HF361, PV, PVPG 14.26 15.45 — 6.64 9.01 5.05 10.17 S6 14<br />

HF361J, JW 14.27 17.33 — 6.65 9.02 5.32 10.46 — 14<br />

HF361L 16.26 17.46 — 9.15 11.53 5.05 10.17 S16 19<br />

HF361N 14.26 15.45 — 6.64 9.01 5.05 10.17 S6 14<br />

HF361NR 14.39 — 15.77 6.64 9.01 5.05 10.17 S8 15<br />

HF361R, RPV, RPVPG 14.39 — 15.77 6.64 9.01 5.05 10.17 S8 15<br />

HF361RL, RW 16.26 — 17.77 9.16 11.53 5.05 10.17 S17 20<br />

HF361S, SS, SSW, SW 14.27 17.33 — 6.65 9.02 5.32 10.46 — 15<br />

HF362, PV, PVPG 16.26 17.46 — 9.15 11.53 5.05 10.17 S16 19<br />

*For inches / millimeters conversion, multiply inches<br />

by 25.4.<br />

a Knocks not provided on Type 4 / 4X and 12 or in 800 &<br />

1200A switches.<br />

4-24<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


General and Heavy Duty Safety Switches<br />

Dimensions<br />

Safety Switch Dimensions (Inches)* & Shipping Weights<br />

Catalog Number<br />

Height Width Depth<br />

Box<br />

A<br />

With<br />

Door<br />

B<br />

With<br />

Rain Shed<br />

C<br />

Box<br />

D<br />

With<br />

Handle<br />

E<br />

Box<br />

F<br />

With<br />

Handle<br />

G<br />

Knockout<br />

Diagram <br />

Shipping<br />

Weight<br />

(lbs.)<br />

HF362J, JW 16.27 19.31 — 9.17 11.47 5.33 10.46 — 20<br />

HF362N 16.26 17.46 — 9.15 11.53 5.05 10.17 S16 19<br />

HF362NR 16.26 — 17.77 9.16 11.53 5.05 10.17 S17 20<br />

HF362R, RPV, RPVPG, RW 16.26 — 17.77 9.16 11.53 5.05 10.17 S17 20<br />

HF362RL 21.95 — 23.46 9.64 11.97 5.05 10.17 S11 25<br />

HF362S, SS, SSW, SW 16.27 19.31 — 9.17 11.47 5.33 10.46 — 20<br />

HF363, PV, PVPG 21.95 23.15 — 9.64 12.01 5.05 10.17 S10 24<br />

HF363J, JW 21.96 23.16 — 9.65 12.02 5.34 10.46 — 25<br />

HF363N 21.95 23.15 — 9.64 12.01 5.05 10.17 S10 25<br />

HF363NR 21.95 — 23.46 9.64 11.97 5.05 10.17 S11 26<br />

HF363R, RPV, RPVPG 21.95 — 23.46 9.64 11.97 5.05 10.17 S11 25<br />

HF363S, SS, SSW, SW 21.96 23.16 — 9.65 12.02 5.34 10.46 — 25<br />

HF364, PV, PVPG 29.9 31.07 — 14.62 16.98 6.36 12.33 S12 48<br />

HF364J, JW 29.96 31.07 — 14.62 16.95 6.63 12.58 — 49<br />

HF364N 29.9 31.07 — 14.62 16.98 6.36 12.33 S12 49<br />

HF364NR 29.9 — 31.42 14.61 16.99 6.36 12.33 S13 48<br />

HF364R, RPV, RPVPG 29.9 — 31.42 14.61 16.99 6.36 12.33 S13 49<br />

HF364S, SS, SSW, SW 29.96 31.07 — 14.62 16.95 6.63 12.58 — 49<br />

HF365A 45.32 45.81 — 22.4 23.404 6.94 9.93 S18 93<br />

HF365JA, HF365JWA 45.32 45.81 — 22.4 23.404 6.97 10.05 — 93<br />

HF365NA 45.32 45.81 — 22.4 23.404 6.94 9.93 S18 94.6<br />

HF365NRA 45.32 45.81 — 22.4 23.404 6.94 9.93 S19 94.6<br />

HF365RA 45.32 45.81 — 22.4 23.404 6.94 9.93 S19 93<br />

HF365SA, HF365SWA 45.32 45.81 — 22.4 23.404 7.34 10.347 — 93<br />

HF365SSA, HF365SSWA 45.32 45.81 — 22.4 23.404 7.34 10.347 — 93<br />

HF366A 45.32 45.81 — 22.4 23.404 6.94 9.93 S18 98<br />

HF366JA, HF366JWA 45.32 45.81 — 22.4 23.404 6.97 10.05 — 98<br />

HF366NA 45.32 45.81 — 22.4 23.404 6.94 9.93 S18 99.6<br />

HF366NRA 45.32 45.81 — 22.4 23.404 6.94 9.93 S19 99.6<br />

HF366RA 45.32 45.81 — 22.4 23.404 6.94 9.93 S19 98<br />

HF366SA 45.32 45.81 — 22.4 23.404 7.34 10.347 — 98<br />

HF366SSA 45.32 45.81 — 22.4 23.404 7.34 10.347 — 98<br />

HF367 66.67 67.16 — 38.4 39.96 9.24 14.68 — 380<br />

HF367J 66.67 67.16 — 38.4 39.96 9.24 14.68 — 380<br />

HF367N 66.67 67.16 — 38.4 39.96 9.24 14.68 — 382<br />

HF367NR 66.67 — 67.74 38.4 40.25 9.24 14.68 — 386<br />

HF367R 66.67 — 67.74 38.4 40.25 9.24 14.68 — 382<br />

HF367S 66.67 67.16 — 38.4 39.96 9.24 14.68 — 380<br />

HF368, J, S 66.67 67.16 — 38.4 39.96 9.24 14.68 — 383<br />

HF368N 66.67 67.16 — 38.4 39.96 9.24 14.68 — 385<br />

HF368NR 66.67 — 67.74 38.4 40.25 9.24 14.68 — 388<br />

HF368R 66.67 — 67.74 38.4 40.25 9.24 14.68 — 385<br />

HNF365JA 45.32 45.81 — 22.4 23.404 6.97 10.05 — 75<br />

HNF365RA 33.47 33.96 — 22.4 23.404 6.94 9.93 S19 75<br />

HNF365SA 33.47 33.96 — 22.4 23.404 7.34 10.347 — 75<br />

HNF365SSA 33.47 33.96 — 22.4 23.404 7.34 10.347 — 75<br />

HNF366SA 33.47 33.96 — 22.4 23.404 7.34 10.347 — 77<br />

HNF366SSA 33.47 33.96 — 22.4 23.404 7.34 10.347 — 77<br />

HNF366JA 45.32 45.81 — 22.4 23.404 6.97 10.05 — 77<br />

HNF366RA 33.47 33.96 — 22.4 23.404 6.94 9.93 S19 77<br />

HNF361, PV, PVPG also HNF261 & HNF362H 11.11 12.31 — 6.64 9.01 5.05 10.17 S7 12<br />

HNF361J, JW also HNF261J & HNF362JH 11.12 14.14 — 6.65 9.02 5.56 10.46 — 13<br />

HNF361R, RPV, RPVPG also HNF261R & HNF362RH 11.11 — 12.63 6.64 9.01 5.05 10.17 S9 13<br />

HNF361RL 16.26 — 17.77 9.16 11.53 5.05 10.17 S17 20<br />

HNF361S, SS, SSW, SW also HNF261S & HNF362SH 11.12 14.14 — 6.65 9.02 5.56 10.46 — 13<br />

HNF362, PV, PVPG also HNF262 16.26 17.46 — 9.15 11.53 5.05 10.17 S16 18<br />

HNF362J, JW also HNF262J 16.27 17.46 — 9.17 11.47 5.33 10.46 — 19<br />

HNF362R, RPV, RPVPG also HNF262R 16.26 — 17.77 9.16 11.53 5.05 10.17 S17 19<br />

HNF362RL 21.95 — 23.46 9.64 11.97 5.05 10.17 S11 24<br />

HNF362S, SS, SSW, SW also HNF262S 16.27 17.46 — 9.17 11.47 5.33 10.46 — 19<br />

HNF363, PV, PVPG also HNF263 21.95 23.15 — 9.64 12.01 5.05 10.17 S10 23<br />

HNF363J, JW also HNF263J 21.96 23.16 — 9.65 12.02 5.34 10.46 — 24<br />

HNF363R, RPV, RPVPG also HNF263R 21.95 — 23.46 9.64 11.97 5.05 10.17 S11 24<br />

HNF363S, SS, SSW, SW also HNF263S 21.96 23.16 — 9.65 12.02 5.34 10.46 — 24<br />

4 SAFETY<br />

SWITCHES<br />

*For inches / millimeters conversion, multiply inches by 25.4.<br />

a Knocks not provided on Type 4 / 4X and 12 or in 800 & 1200A switches.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 4-25


General and Heavy Duty Safety Switches<br />

Revised on 02/28/19<br />

Dimensions<br />

Safety Switch Dimensions (Inches)* & Shipping Weights<br />

4<br />

SAFETY<br />

SWITCHES<br />

Catalog Number<br />

Height Width Depth<br />

Box<br />

A<br />

With<br />

Door<br />

B<br />

With<br />

Rain Shed<br />

C<br />

Box<br />

D<br />

With<br />

Handle<br />

E<br />

Box<br />

F<br />

With<br />

Handle<br />

G<br />

Knockout<br />

Diagram <br />

Shipping<br />

Weight<br />

(lbs.)<br />

HNF364, PV, PVPG 29.9 31.07 — 14.62 16.98 6.36 12.33 S12 46<br />

HNF364J, JW 29.96 31.07 — 14.62 16.95 6.63 12.58 — 47<br />

HNF364R, RPV, RPVPG 29.9 — 31.42 14.61 16.99 6.36 12.33 S13 47<br />

HNF364S, SS, SSW, SW 29.96 31.07 — 14.62 16.95 6.63 12.58 — 47<br />

HNF365JA 45.32 45.81 — 22.4 23.404 6.97 10.05 — 75<br />

HNF365JWA 45.32 45.81 — 22.4 23.404 6.97 10.05 — 75<br />

HNF365RA 33.47 33.96 — 22.4 23.404 6.94 9.93 S19 75<br />

HNF365SA, HNF365SWA 33.47 33.96 — 22.4 23.404 7.34 10.347 — 75<br />

HNF365SSA, HNF365SSWA 33.47 33.96 — 22.4 23.404 7.34 10.347 — 75<br />

HNF366JA 45.32 45.81 — 22.4 23.404 6.97 10.05 — 77<br />

HNF366RA 33.47 33.96 — 22.4 23.404 6.94 9.93 S19 77<br />

HNF366SA 33.47 33.96 — 22.4 23.404 7.34 10.347 — 77<br />

HNF367, J 54.67 55.16 — 38.4 39.96 9.24 14.68 — 302<br />

HNF367R 54.67 — 55.7 38.4 40.25 9.24 14.68 — 304<br />

HNF367S 54.67 55.16 — 38.4 39.96 9.24 14.68 — 302<br />

HNF368, J, S 54.67 55.16 — 38.4 39.96 9.24 14.68 — 305<br />

HNF368R 54.67 55.16 — 38.4 40.25 9.24 14.68 — 307<br />

LF111N 7.97 8.13 — 5.5 5.94 3 5.38 S2 35 (10)<br />

LF111NR 8.07 — 8.16 5.16 5.94 3.13 5.38 S3 35 (10)<br />

LF211N 7.97 8.13 — 5.5 5.94 3 5.38 S1 35 (10)<br />

LF211NR 8.07 — 8.16 5.16 5.94 3.13 5.38 S3 35 (10)<br />

Type 1 or 3R<br />

30-60A GD<br />

Type 1 or 3R<br />

100-200A GD, 30-200A HD Type VBII<br />

Type 4/4X or 12<br />

30-200A HD Type VBII<br />

Type 1 or 3R<br />

400-1200A Type VBII (GD & HD)<br />

Type 4/4X or 12<br />

400-1200A HD Type VBII<br />

*For inches / millimeters conversion, multiply inches<br />

by 25.4.<br />

a Knocks not provided on Type 4 / 4X and 12 or in 800 &<br />

1200A switches.<br />

4-26<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


General and Heavy Duty Safety Switches<br />

Revised on 02/28/19<br />

Knockout Diagrams<br />

Type 1 & 3R Enclosures<br />

30A F / NF & 60A NF Type 1 Enclosures<br />

30A F / NF & 60A NF Type 3R Enclosures<br />

S4<br />

Embossed .25 in.<br />

mounting holes<br />

(3 places)<br />

2 0.25 dia. K.O's<br />

S5<br />

Removable<br />

plate covering<br />

HA Type<br />

Hub opening<br />

(Max. 1.25 Conduit)<br />

Embossed .25 in.<br />

mounting holes<br />

(3 places)<br />

2 0.25 dia. K.O's<br />

4 SAFETY<br />

SWITCHES<br />

3 K.O.'s for Conduit 0.5-0.75-1 in.<br />

2 K.O.'s for Conduit 0.5-0.75-1 in.<br />

Removable plate covering<br />

HS Type Hub opening<br />

(Max. 2.5 Conduit)<br />

Removable plate covering<br />

HS Type Hub opening<br />

(Max. 2.5 Conduit)<br />

S8<br />

S9<br />

2 K.O.'s for Conduit<br />

0.75, 1 in.<br />

5 K.O.'s for Conduit<br />

0.50, 0.75, 1 in.<br />

1 0.25 dia. K.O.<br />

2 K.O.'s for Conduit<br />

0.75, 1 in.<br />

5 K.O.'s for Conduit<br />

0.50, 0.75, 1 in.<br />

1 0.25 dia. K.O.<br />

*For inches / millimeters conversion, multiply inches<br />

by 25.4.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 4-27


General and Heavy Duty Safety Switches<br />

Revised on 02/28/19<br />

Knockout Diagrams<br />

Type 1 & 3R Enclosures<br />

SAFETY<br />

SWITCHES<br />

4<br />

60A NF LNF 3R Enclosures<br />

60A F Type 1 Enclosures<br />

S20<br />

Embossed .25 in.<br />

mounting holes<br />

(3 places)<br />

S21<br />

Embossed .25 in.<br />

mounting holes<br />

(3 places)<br />

2 0.25 dia. K.O's<br />

2 0.25 dia. K.O's<br />

2 K.O.'s for Conduit 0.5-0.75-1 in.<br />

5 K.O.'s for Conduit 0.5-0.75-1 in.<br />

60A F Type 3R Enclosures<br />

Removable<br />

plate covering<br />

HA Type<br />

Hub opening<br />

(Max. 1.25 Conduit)<br />

S22<br />

Embossed .25 in.<br />

mounting holes<br />

(3 places)<br />

2 0.25 dia. K.O's<br />

3 K.O.'s for Conduit 0.5-0.75-1 in.<br />

*For inches / millimeters conversion, multiply inches<br />

by 25.4.<br />

4-28<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Special Application Safety Switches Dimension Drawings<br />

Non-Metallic<br />

Dimensions<br />

Non-Metallic<br />

Catalog<br />

Dimensions (Inches) Non-Metallic<br />

Number H W D A B C E F G J<br />

HF321NX 18.75 12.11 10.25 16.59 10.97 7.00 17.50 1.98 .46 9.20<br />

HF322NX 18.75 12.11 10.25 16.59 10.97 7.00 17.50 1.98 .46 9.20<br />

HF361NX a 18.75 12.11 10.25 16.59 10.97 7.00 17.50 1.98 .46 9.20<br />

HF362NX a 18.75 12.11 10.25 16.59 10.97 7.00 17.50 1.98 .46 9.20<br />

HF363NX a 26.95 14.87 13.25 24.84 13.72 6.25 25.75 3.75 .46 12.15<br />

HF364NX a 33.41 27.47 13.19 31.31 26.31 18.50 32.25 3.91 .47 12.10<br />

HNF361X a 18.75 12.11 10.25 16.59 10.97 7.00 17.50 1.98 .46 9.20<br />

HNF362X a 18.75 12.11 10.25 16.59 10.97 7.00 17.50 1.98 .46 9.20<br />

HNF363X a 26.95 14.87 13.25 24.84 13.72 6.25 25.75 3.75 .46 12.15<br />

HNF364X a 33.41 27.47 13.19 31.31 26.31 18.50 32.25 3.91 .47 12.10<br />

4 SAFETY<br />

SWITCHES<br />

VBII Interlocked Receptacle Switches<br />

Ampere<br />

Dimensions (Inches)<br />

Rating A B C D E F G<br />

Cr-H Type Fusible (240 & 600V)<br />

30 14.27 7.42 9.02 6.22 1.52 6.1 6.0<br />

60 16.27 9.17 11.47 6.34 1.52 6.4 7.4<br />

100 21.96 9.65 12.02 6.80 1.52 6.5 7.6<br />

Cr-H Type Non-Fusible (600V max.)<br />

30 14.27 7.42 9.02 6.22 1.52 6.1 6.0<br />

60 16.27 9.17 11.47 6.34 1.52 6.4 7.4<br />

100 21.96 9.65 12.02 6.80 1.52 6.5 7.6<br />

Pyle-National Type Fusible (240 & 600V)<br />

30 14.27 7.42 9.02 6.22 1.52 3.5 3.0<br />

60 16.27 9.17 11.47 6.34 1.52 5.0 4.5<br />

Pyle-National Type Non-Fusible (600V max.)<br />

30 14.27 7.42 9.02 a 6.22 1.52 3.5 3.0<br />

60 16.27 9.17 11.47 a 6.34 1.52 5.0 4.5<br />

*For inches / millimeters conversion, multiply inches<br />

by 25.4.<br />

a Dimensions also apply to “L” suffix switches (less<br />

lugs).<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 4-29


Special Application Safety Switches Dimension Drawings<br />

4-Pole & 6-Pole<br />

Dimensions<br />

4<br />

SAFETY<br />

SWITCHES<br />

4 & 6-Pole Safety Switch Dimensions – Inches (mm)<br />

Enclosure<br />

Mounting<br />

Catalog<br />

Number A B C D E F<br />

Figure 1, 4-Pole Fusible and Non-fusible, Type 1<br />

HNF461 24.50 (622) 9.53 (242) 6.09 (155) 19.00 (483) 6.75 (171) 0.268 (7)<br />

HF461 29.12 (740) 9.53 (242) 6.09 (155) 23.50 (597) 6.75 (171) 0.268 (7)<br />

HNF462 24.88 (632) 11.50 (292) 6.09 (155) 19.00 (483) 9.38 (238) 0.268 (7)<br />

HF462 33.53 (852) 11.50 (292) 6.09 (155) 27.50 (699) 9.38 (238) 0.268 (7)<br />

HNF463 27.62 (702) 12.18 (309) 6.09 (155) 19.36 (492) 8.00 (203) 0.268 (7)<br />

HF463 36.44 (926) 12.18 (309) 6.09 (155) 28.11 (714) 8.00 (203) 0.268 (7)<br />

HNF464 36.00 (914) 19.12 (486) 6.42 (163) 30.88 (784) 15.00 (381) 0.44 (11)<br />

HF464 49.48 (1257) 19.12 (486) 6.42 (163) 45.50 (1130) 15.00 (381) 0.44 (11)<br />

Figure 2, 4 & 6-Pole Fusible Type 12/3R and 4X<br />

HF461J, HF661J, 29.50 (622) 9.53 (242) 6.48 (165) 31.65 (804) 5.47 (139) 0.27 (7)<br />

HF661S<br />

HF462J, HF662J, 33.53 (852) 11.50 (292) 6.48 (165) 35.69 (907) 8.00 (203) 0.27 (7)<br />

HF662S<br />

HF463J, HF663J, 36.44 (926) 12.18 (309) 6.48 (165) 38.67 (982) 8.47 (215) 0.27 (7)<br />

HF663S<br />

HF464J, HF664J, 49.48 (1257) 19.12 (486) 6.78 (172) 51.64 (1312) 13.44 (341) 0.33 (8)<br />

HF664S<br />

Figure 2, 4 & 6-Pole Non-fusible Type 12/3R and 4X<br />

HNF461J, HNF661J, 24.50 (622) 9.53 (242) 6.48 (165) 26.65 (667) 5.47 (139) 0.27 (7)<br />

HNF661S<br />

HNF462J, HNF662J, 24.88 (632) 11.50 (292) 6.48 (165) 27.03 (687) 8.00 (203) 0.27 (7)<br />

HNF662S<br />

HNF463J, HNF663J, 27.54 (700) 12.18 (309) 6.48 (165) 29.77 (756) 8.47 (215) 0.27 (7)<br />

HNF663S<br />

HNF464J, HNF664J, 36.00 (914) 19.12 (486) 6.78 (172) 38.16 (969) 13.44 (341) 0.33 (8)<br />

HNF664S<br />

Figure 1: Type 1<br />

Figure 2 : Type 12/3R and 4X<br />

4-30<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Special Application Safety Switches Dimension Drawings<br />

Double Throw<br />

Selection<br />

Description<br />

Double throw switches are intended to transfer loads<br />

from one power source to another. All 2 & 3-pole<br />

double throw switches are suitable for use as service<br />

equipment including non-fusible versions when used<br />

in combination with a UL listed circuit breaker or fusible<br />

switch. All are UL Listed and both horsepower<br />

and load break rated. Switches are rated for use on<br />

systems up to 10,000A when protected with Class<br />

H fuses or 100,000A when protected with Class R or<br />

Class T fuses b . They can also be used to connect a<br />

single source of power to either of two loads. In<br />

this application it is necessary to field modify fusible<br />

Double Throw Switches<br />

switches so that the fuses are on the load side of the<br />

switching mechanism.<br />

A cover interlock is provided on all ampere ratings. The<br />

operating handle may be padlocked in the off position.<br />

Fuse Capabilities of Fusible DTF Switches<br />

Amp<br />

Fuse Type<br />

Rating<br />

H R T J<br />

30 & 60A, 240V Std Yes (kit) No No<br />

30 & 60A, 600V Std Yes (kit) No Yes c<br />

100 & 200A Std Yes (kit) Yes (kit) Yes c<br />

400 & 600A (DTF) No No Yes c Std<br />

Number<br />

Type 1 — Indoor Type 3R — Outdoor a Type 12/3R — Industrial Type 4X — Stainless Steel<br />

System<br />

Voltage of Poles Amps Catalog Number Catalog Number Catalog Number Catalog Number<br />

Heavy Duty Fusible (30-200A) with Class H fuse spacings —Less Neutral b<br />

240<br />

Volt AC<br />

or<br />

250<br />

Volt DC<br />

600<br />

Volt AC,<br />

250<br />

Volt DC<br />

Heavy Duty Non-Fusible —Less Neutral b<br />

240<br />

Volt AC<br />

or<br />

250<br />

Volt DC<br />

600<br />

Volt AC,<br />

or<br />

250<br />

Volt DC<br />

General Duty Non-Fusible<br />

240<br />

Volt AC<br />

2 200 DTF224s DTF224R — —<br />

30 DTF321 DTF321Rs — —<br />

60 DTF322 DTF322Rs — —<br />

3<br />

100 DTF323s DTF323R — —<br />

200 DTF324 DTF324R — —<br />

400 DTF325 FR325DTK s — —<br />

600 DTF326s FR326DTK d s — —<br />

30 DTF361 — — —<br />

60 DTF362s — — —<br />

3 100 DTF363 DTF363R — F353SSDTK s<br />

200 DTF364 DTF364R — F354SSDTK s<br />

400 DTF365 FR355DTK d s — F355SSDTK s<br />

30 DTNF221 — — —<br />

60 DTNF222 — — —<br />

2 100 DTNF223 — — —<br />

200 DTNF224 DTNF224R — —<br />

400 DTNF225 DTNF225R — —<br />

30 DTNF321 — — —<br />

60 DTNF322 — — —<br />

100 DTNF323 DTNF323R — —<br />

3 200 DTNF324 DTNF324R — —<br />

400 DTNF325 — — —<br />

600 DTNF326 — — —<br />

800 DTNF327s — — —<br />

30 DTNF361 DTNF361R DTNF361J DTNF361S<br />

60 DTNF362 DTNF362R DTNF362J DTNF362S<br />

100 DTNF363 DTNF363R DTNF363J DTNF363S<br />

3 200 DTNF364 DTNF364R DTNF364Js DTNF364S<br />

400 DTNF365 DTNF365R NF355HDTK NF355SSDTK<br />

600 DTNF366 DTNF366R — —<br />

800 DTNF367 DTNF367R — —<br />

1200 DTNF368s DTNF368R — —<br />

30 — NFR451DTKs — —<br />

60 — NFR452DTKs — —<br />

100 — NFR453DTKs — —<br />

4 e 200 NF454DTK NFR454DTKs — NF454SSDTKs<br />

400 NF455DTKs NFR455DTKs — —<br />

600 NF456DTKs NFR456DTKs — —<br />

800 NF457DTKs NFR457DTKs — —<br />

2<br />

3<br />

Type 3R — Outdoor a<br />

Less Neutral<br />

Type 3R — Outdoor a<br />

With Neutral<br />

Type 3R — Outdoor General<br />

Duty With Neutral <br />

100 DTGNF223R DTGNF223NR DTLNF213NR —<br />

200 DTGNF224R DTGNF224NR — —<br />

100 DTGNF323R DTGNF323NR — —<br />

200 DTGNF324R DTGNF324NR — —<br />

4 SAFETY<br />

SWITCHES<br />

s Built to order. Allow 3–4 weeks for delivery.<br />

a Use HS Type hubs for 30–200A switches.<br />

400A and larger switches do not have hub provisions.<br />

b All Heavy Duty double throw switches with a catalog<br />

number starting with “DT” are rated 200,000 AIC max.<br />

when protected by Class R, J or T fuses. Fuse ampere<br />

rating must not exceed switch ampere rating.<br />

c Move load base.<br />

d Will accept class T Fuses only.<br />

e 4-pole switches are not approved for service entrance.<br />

Will accept class H fuses only.<br />

General duty Stand-by Power Panel catalog number<br />

DTLNF213NR contains (2) 100A, 2P circuit breakers<br />

rated 120/240V AC & 10,000 AIC.<br />

Product Category HDSS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 4-31


Safety Switches<br />

Double Throw<br />

Selection<br />

4<br />

SAFETY<br />

SWITCHES<br />

Accessories, Lug Data and Horsepower Ratings<br />

Accessories – 2 and 3-Pole Switches Type “DT” Only a<br />

Catalog<br />

Description<br />

Number<br />

30A<br />

HNC612<br />

60 & 100A HN263<br />

Neutral Kits 200A HNC264<br />

400 & 600A HN678<br />

800 & 1200A HND678<br />

30-200A (2) #14-4 AWG HG61234<br />

Equipment<br />

400 & 600A (4) #14-2/0 HG656<br />

Ground Kit<br />

800-1200A (8) #6-350 Kcmil HG678<br />

30-200A with (1) NO & (1) NC contact HA161234<br />

Auxiliary Contacts (HD only) 30-200A with (2) NO & (2) NC contacts HA261234<br />

(two required per switch) d 400-1200A with (1) NO & (1) NC contact HA165678<br />

400-1200A with (2) NO & (2) NC contacts HA265678<br />

30A, 240V Kit HR21<br />

Class R Fuse Clip Kits 30A, 600V Kit/60A, 240V Kit HR612<br />

(two required per switch) 60A, 600V Kit HR62<br />

100A Kit<br />

HR63<br />

200A Kit<br />

HR64<br />

100A, 240V Kit HT23<br />

Class T Fuse Adapter Kits 100A, 600V Kit HT63<br />

(two required per pole) 200A, 240V Kit HT24<br />

200A, 600V Kit HT64<br />

For 3 ⁄4" Conduit<br />

ECHS075<br />

For 1" Conduit<br />

ECHS100<br />

Type 3R Hubs (30-200A) For 1 1 ⁄4" Conduit ECHS125<br />

For 1 1 ⁄2" Conduit<br />

ECHS150<br />

For 2" Conduit<br />

ECHS200<br />

For 2 1 ⁄2" Conduit<br />

ECHS250<br />

Accessories – 4-Pole and Type “F” & “NF” 3-Pole Switches Only b<br />

Catalog<br />

Description<br />

Number<br />

Auxiliary Switch<br />

(1) NO, (1) NC d DS200EK1<br />

(two required per switch)<br />

30-800A<br />

(2) NO, (2) NC d DS200EK2<br />

30-60-100A<br />

DS100GK<br />

Ground Lug Kit c 200A DS200GK<br />

400-600-800A<br />

DS468GK<br />

30-60-100A Use Type HR Hubs<br />

Hubs 200-400A Use Type SSH 4, 4X Hubs<br />

600-800A Use Type SSH 4, 4X Hubs<br />

Neutrals (3-pole only) 30-60-100A DT100NK<br />

200A<br />

DT200NK<br />

400 & 600A Fusible DS800NK<br />

400A 3P Non-Fusible<br />

DT600NK<br />

Wire Ranges (Line, Load<br />

and Neutral) per NEC<br />

Requirements<br />

30-200A – 2, 3 & 4-Pole Switches<br />

Switch Wire Range (Cu/Al)<br />

Ampere New VBII Design<br />

Rating Line, Load and Neutral<br />

0 30 (1) #14–6<br />

060 (1) #14–2<br />

100 (1) #14–1/0 AWG<br />

100 (1) #14–1/0 AWG<br />

200 (1) #6–250 kcmil<br />

400-1200A – 2 & 3-Pole Switches<br />

Switch Wire Range (Cu/Al)<br />

Ampere New VBII Design<br />

Rating Line, Load and Neutral<br />

400<br />

(1) 1/0 AWG–750 kcmil or<br />

(2) 1/0 AWG–250 kcmil<br />

600 (2) 1/0 AWG–500 kcmil<br />

800<br />

(2) 1/0 AWG–750 kcmil or<br />

(3) 1/0 AWG–500 kcmil<br />

1200<br />

(3) 1/0 AWG–600 kcmil or<br />

(4) 1/0 AWG–500 kcmil<br />

400-800A – 4-Pole switches<br />

Switch Wire Range (Cu/Al)<br />

Ampere New VBII Design<br />

Rating Line, Load and Neutral<br />

400<br />

(2) 1/0 AWG–300 kcmil or<br />

(1) 1/0 AWG–750 kcmil<br />

600 (2) 250-500 Kcmil<br />

800 (3) 250-500 Kcmil<br />

Maximum Horsepower Ratings<br />

Fused<br />

Ampere<br />

1-Phase AC<br />

3-Phase AC<br />

250V<br />

Rating 240V 240V 480V 600V DC<br />

0 30 03 0 7 1 ⁄2 015 020 05<br />

0 60 10 15 030 050 10<br />

100 15 30 060 075 20<br />

200 15 60 125 150 40<br />

400 — 125 125 125 50<br />

600 — 125 — — 50<br />

Non-Fused<br />

0 30 05 10 020 030 05<br />

0 60 10 20 050 060 10<br />

100 15 40 075 100 20<br />

200 15 60 125 150 40<br />

400-800 — 125 250 350 50<br />

Replacement Parts – 2 and 3-Pole Switches Only a<br />

Catalog<br />

Description<br />

Number<br />

Type 1, 3R & 12 Replacement Handle 30-200A HHD61234<br />

Type 4X Replacement Handle 30-200A HHD61234S<br />

Replacement Handle 400-1200A HHD656<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

a For “DT” VBII Type switches only.<br />

b Also for fusible stainless & 400A Type 12 & 4x switches.<br />

c The following ground lugs are provided as standard in<br />

200A and larger switches 200-(1) #14-4 Cu/Al<br />

400-800A-(3) #6-250MCM Cu/Al.<br />

d One aux. required for normal and one required for<br />

emergency switch line base.<br />

4-32<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category HDSS & RESI


Safety Switches<br />

Revised on 12/17/17<br />

Dimensions<br />

VBII Design Double Throw Dimensions (Inches)<br />

Enclosure<br />

Mounting<br />

Catalog Number A B C D E F<br />

Figure 1 (30-1200A Type 1 & 3R)<br />

DTNF221, DTNF321, DTNF361, DTNF361R 24.50 9.53 6.09 19.00 6.75 0.268<br />

DTF321, DTF321R, DTF361 29.12 9.53 6.09 23.50 6.75 0.268<br />

DTNF222, DTNF322, DTNF362, DTNF362R 24.88 11.50 6.09 19.00 9.38 0.268<br />

DTF322, DTF322R, DTF362 33.45 11.50 6.09 27.50 9.38 0.268<br />

DTNF223, DTNF323, DTNF323R, DTNF363, DTNF363R,<br />

DTGNF223R, DTGNF223NR, DTGNF323R , DTGNF323NR<br />

27.62 12.18 6.09 19.36 8.00 0.268<br />

DTF323, DTF323R, DTF363, DTF363R 36.44 12.18 6.09 28.11 8.00 0.268<br />

DTNF224, DTNF224R, DTNF324, DTNF324R, DTNF364, DTNF364R,<br />

DTGNF224R, DTGNF224NR, DTGNF324R, DTGNF324NR<br />

36.00 19.12 6.42 31.00 15.00 0.44<br />

DTF224, DTF224R, DTF324, DTF324R, DTF364, DTF364R 49.44 19.12 6.42 44.50 15.00 0.44<br />

DTF325, DTF326, DTF365 73.54 28.22 9.44 65.50 16.00 0.56<br />

DTNF225, DTNF225R, DTNF325, DTNF365, DTNF365R 57.71 28.22 9.44 49.75 16.00 0.56<br />

DTNF326, DTNF366, DTNF366R 57.71 28.22 9.44 49.75 16.00 0.56<br />

DTNF327, DTNF367, DTNF367R 71.65 41.60 9.44 63.70 32.00 0.56<br />

DTNF368, DTNF368R 71.65 41.60 9.44 63.70 32.00 0.56<br />

FR325DTK c , FR355DTK c 74.31 24.90 8.88 69.50 20.25 0.56<br />

FR326DTK c 85.65 27.00 8.88 80.75 22.25 0.56<br />

NFR451DTK c , NFR452DTK c , NFR453DTK c 24.63 17.34 4.78 21.50 14.97 0.27 <br />

NF454DTK bc , NFR454DTK bc 37.25 19.19 6.32 33.50 16.00 0.56 <br />

NF455DTK c , NF456DTK c , NF457DTK c ,<br />

NFR455DTK c , NFR456DTK c , NFR457DTK c 63.31 27.00 8.88 58.50 22.25 0.56 <br />

Figure 2 (30-200A Type 12 & 4X)<br />

4 SAFETY<br />

SWITCHES<br />

DTNF361J, DTNF361S 24.42 9.65 6.48 26.65 5.47 0.27<br />

DTNF362J, DTNF362S 24.80 11.61 6.48 27.03 8.00 0.27<br />

DTNF363J, DTNF363S 27.54 12.29 6.48 29.77 8.47 0.27<br />

DTNF364J, DTNF364S 35.93 19.24 6.78 38.16 13.44 0.33<br />

NF355HDTK ac , NF355SSDTK ac 53.82 22.66 7.25 56.20 18.00 0.56<br />

NF454SSDTK c 37.47 19.16 6.48 39.75 15.75 0.50 <br />

F353SSDTK bc 37.00 11.62 5.50 38.50 9.00 0.26<br />

F354SSDTK bc 50.90 19.16 6.46 53.27 16.12 0.50<br />

F355SSDTK bc 74.50 25.00 8.92 76.69 20.25 0.56<br />

Figure 1<br />

Figure 2<br />

Type 1 & 3R d Type 4X & 12<br />

*For inches / millimeters conversion, multiply inches<br />

by 25.4.<br />

a (3) Mounting holes supplied (1 at top).<br />

b (4) Mounting holes provided.<br />

c These switches are not Type VBII design.<br />

d Drip hood not shown but provided on<br />

Type 3R enclosures.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 4-33


Enclosed Switches<br />

Rotary Disconnect Switches in Non-Metallic Enclosures e<br />

Selection<br />

4<br />

SAFETY<br />

SWITCHES<br />

Description<br />

16–125A non-fusible switches are available<br />

in fiberglass reinforced polycarbonate<br />

enclosures which are UL approved as Type<br />

12 & 4X and for either indoor or outdoor<br />

use. All are horsepower and load break<br />

rated. All are panel mounted and are either<br />

supplied with factory installed aux. contacts<br />

or will accept contact kits. All are compact<br />

in size while providing ample wiring space<br />

for copper line & load conductors.<br />

Catalog Number<br />

Siemens Enclosed Rotary Disconnect Switches<br />

b 16–125A, Non-Fusible<br />

b 600VAC max. rated<br />

b Available in both Type 12 and 4X<br />

non-metallic enclosures<br />

b Both screw and hinged cover<br />

designs available<br />

b Listed and marked “suitable for use<br />

as motor disconnect” per NEC<br />

Section 430-109<br />

b Screw cover switches are UL listed<br />

under File No. E47705 and are CSA<br />

certified under File No. 203576<br />

b IEC 60947-3 rated and CE marked<br />

(enclosures are IP65 rated)<br />

b HP rated<br />

Horsepower Ratings<br />

Ampere 3 Pole, 3 Wire with (1) NO Shipping 240V AC 480V AC 600V AC<br />

Rating 3 Pole, 3 Wire & (1) NC Aux. Contact hi Weight a 1 Phase 3 Phase 3 Phase 3 Phase<br />

Non-Fusible, Type 1, 4X & 12K b with Screw Cover and Black Rotary Handle 600V AC Max. e<br />

b Hinged door switches are UL listed<br />

for multiple line and load conductors<br />

per phase in 30–100A ratings.<br />

They are UL & CUL listed under File<br />

No. E191706<br />

b Rotary handles are available in<br />

black, red, and yellow and in pistol<br />

grip designs<br />

b 16–63A screw cover switches have<br />

factory installed ground bars. All<br />

hinge cover switches accept ground<br />

lug kits<br />

b Screw cover switches are<br />

provided with knockouts<br />

b Padlockable in OFF position<br />

with up to (3) padlocks<br />

16 3LD2064-0TB51-0US2 3LD2064-1GP51-0US2 1 1 1 ⁄2 3 7 1 ⁄2 10<br />

25 3LD2164-0TB51-0US2 3LD2164-1GP51-0US2 1 3 7 1 ⁄2 10 15<br />

30 3LD2264-0TB51-0US2 3LD2264-1GP51-0US2 1 3 7 1 ⁄2 15 20<br />

30 — 3LD2264-1TS51-0US2 f s 1 3 7 1 ⁄2 15 20<br />

30 — 3LD2264-2TW51-0US2 g s 1 3 7 1 ⁄2 15 20<br />

63 3LD2565-0TB51-0US2 3LD2565-1GP51-0US2s 3 10 15 40 50<br />

100 3LD2766-0TB51-0US2 3LD2766-1GP51-0US2s 6 — 30 60 75<br />

125 3LD2866-0TB51-0US2 3LD2866-1GP51-0US2s 6 — 40 75 100<br />

Non-Fusible, Type 1, 4X & 12K b with Screw Cover and Red and Yellow Rotary Handle 600V AC Max. e<br />

16 3LD2064-0TB53-0US2 3LD2064-1GP53-0US2 1 1 1 ⁄2 3 7 1 ⁄2 10<br />

25 3LD2164-0TB53-0US2 3LD2164-1GP53-0US2 1 3 7 1 ⁄2 10 15<br />

30 3LD2264-0TB53-0US2 3LD2264-1GP53-0US2 1 3 7 1 ⁄2 15 20<br />

30 — 3LD2264-1TS53-0US2 f s 1 3 7 1 ⁄2 15 20<br />

30 — 3LD2264-2TW53-0US2 g s 1 3 7 1 ⁄2 15 20<br />

63 3LD2565-0TB53-0US2 3LD2565-1GP53-0US2s 3 10 15 40 50<br />

100 3LD2766-0TB53-0US2s 3LD2766-1GP53-0US2s 6 — 30 60 75<br />

125 3LD2866-0TB53-0US2s 3LD2866-1GP53-0US2s 6 — 40 75 100<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

a Carton quantity of (1). Shipping weight in pounds (lbs.).<br />

b Approved for indoor/outdoor use. No cover interlock provided.<br />

c 30 and 60A switches are also rated 600V AC.<br />

d Also rated as Type 12 and UL approved for both indoor and<br />

outdoor use. Defeatable cover interlock provided.<br />

e Screw cover enclosures are constructed from Makrolon 9425.<br />

Hinged cover enclosures are constructed from fiberglass reinforced<br />

polycarbonate.<br />

f Switch is supplied with (2) NO and no NC aux. contacts.<br />

g Switch is supplied with (4) NO and no NC aux. contacts.<br />

Ground bar is not provided or available.<br />

h Aux. contacts break about 3 Ms before and make about 3 Ms<br />

after main switch contacts.<br />

i 6P, 25A, switch with 1 NO & 1 NC aux. contacts and a black<br />

operating handle is also available. Order catalog number<br />

3LD2165-4VD51 (Discount Code: Pilot Devices).<br />

4-34<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category HDSS


Enclosed Switches<br />

Rotary Disconnect Switches<br />

Selection<br />

Enclosed Disconnect Switch Dimensions (Inches)*<br />

Catalog Ampere Fig. Dimensions<br />

Number Rating No. A B C D<br />

3LD2064- 16 5.52 d 3.94 3.19 4.57<br />

3LD2164- 25 5.52 d 3.94 3.19 4.57<br />

3LD2264- 30<br />

1<br />

5.52 d 3.94 3.19 4.57<br />

3LD2565- 63 6.93 e 5.75 4.10 5.87<br />

3LD2766- 100 11.90 8.35 5.36 7.13<br />

3LD2866- 125 11.90 8.35 5.36 7.13<br />

Note: 3LD2 Type switches only have top and bottom end KOs as follows:<br />

16-30A - 1/2” & 3/4”, 63A - 3/4” & 1”, 100 & 25A - 1” & 1 1/4”<br />

Figure 1<br />

UL and CUL Short Circuit Withstand Ratings<br />

Short Circuit Withstand Rating and Fuse Class<br />

With Line Side Fusing<br />

With Load Side Fusing a<br />

Ampere 5 kA at 10 kA at 18 kA at 5 kA at 18 kA at<br />

Rating 600V Max 600V Max 480V Max 480V Max 480V Max<br />

3LD2 Type Switches h<br />

RK5<br />

16<br />

(50A Max)<br />

— — — —<br />

Wire ranges 60/75°C Cu Only<br />

3LD2 Type Switches c<br />

16 Amps (1) #18-10 AWG<br />

25–30 Amps (1) #14-10 AWG<br />

63 Amps (1) #14-6 AWG<br />

100–125 Amps (1) #12-1 AWG<br />

HNF Type Switches<br />

(1) #14-#10 AWG Solid<br />

(1) #14-#4 AWG Stranded<br />

Up to (4) #12 AWG Solid<br />

30 Amps Up to (3) #12 AWG Stranded<br />

Up to (6) #14 AWG Stranded<br />

Up to (4) #14 AWG Stranded<br />

with (1) #10 AWG Stranded<br />

(1) #14-#10 AWG Solid<br />

(1) #14-#1 AWG Stranded<br />

(2) #6 AWG Stranded<br />

60 & 100 Amps<br />

Up to (3) #8 AWG Stranded<br />

Up to (6) #10 AWG Stranded<br />

Up to (6) #12 AWG Solid<br />

Figure 2<br />

4 SAFETY<br />

SWITCHES<br />

25 & 30 RK5 (80A Max)<br />

— — — —<br />

63<br />

RK5<br />

(175A Max)<br />

— — — —<br />

100 &<br />

125<br />

—<br />

RK5<br />

(200A Max)<br />

— — —<br />

HNF Type Switches<br />

30 —<br />

Ferraz<br />

Shawmut<br />

A50P or lower<br />

H, K & RK5 H, K & RK5<br />

let-through<br />

(100A Max) (30A Max)<br />

semiconductor<br />

fuses<br />

J, T & CC<br />

(60A Max)<br />

(100A Max) Ferraz<br />

60<br />

H, K & RK5<br />

Shawmut<br />

(150A Max)<br />

A50P or lower<br />

H, K & RK5<br />

let-through<br />

(60A Max)<br />

f<br />

semiconductor<br />

100 f<br />

fuses<br />

(100A Max)<br />

a For use as supplemental protection on the load side of the branch circuit over current<br />

protective device.<br />

b Ground lug kit has two lugs for #14-4 Cu/Al wire.<br />

c Factory installed ground lugs supplied as follows: 16-30A #14-10 Cu, 63A #14-8 Cu.<br />

Ground lug not provided and is not available on catalog numbers 3LD2264-2TW51-0US2<br />

and 3LD2264-2TW53-0US2.<br />

d 6.38 inches high including mounting feet.<br />

e 7.85 inches high including mounting feet.<br />

f 60 & 100A HNF switches are rated 10kA at 480V max. with line side Class H, K & RK5<br />

150A max. fuses.<br />

g Wire range (1) #14-2 AWG 60/75 °C Cu only.<br />

h 16-63A 3LD switches are also rated 5kA at 600VAC max when protected by a 3RV type<br />

MSP of the same or lesser ampere rating.<br />

*For inches / millimeters conversion, multiply inches by 25.4.<br />

IEC Fuse and Withstand Ratings<br />

Ampere Rating gG Fuse Size Short Circuit Rating<br />

3LD2 Screw Cover Switches<br />

16 20A 5k Arms<br />

25 25A 10k Arms<br />

32 50A 10k Arms<br />

63 63A 15k Arms<br />

100 100A 20k Arms<br />

125 125A 20k Arms<br />

HNF Hinged Cover Switches<br />

30 63A 10k Arms<br />

60 100A 10k Arms<br />

100 100A 10k Arms<br />

Accessories<br />

Switch<br />

Ampere Catalog<br />

Rating Number Description<br />

3LD2 Type Switches c<br />

16–30A 3LD9220-2C Neutral Kit<br />

63A 3LD9250-2CA Neutral Kit<br />

100–125A 3LD9280-2C Neutral Kit<br />

HNF Type Switches<br />

30–100A GSGK60 Ground Lug Kit b<br />

30A LBRA1 Auxiliary Contact Kit (1 NO-1 NC)<br />

60–100A LBRA2 Auxiliary Contact Kit (1 NO-1 NC)<br />

30–100A HF63CX g Neutral Kit<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 4-35


Enclosed Switches<br />

Enclosed Bolted Pressure Switches & Safety Switch Replacement Parts<br />

Selection<br />

For enclosed bolted pressure contact switches order as lug-in/lug-out single section<br />

BPS main switchboards using either the SPACE 2000 Switchboard EPM or COMPAS.<br />

VBII Safety Switch Replacement Parts<br />

Handle / Handle Guard<br />

Ampere<br />

Line Base Load Base General Duty Heavy Duty<br />

Rating Catalog Number Catalog Number Catalog Number Catalog Number<br />

Fusible 2- and 3-Pole 60-600A General Duty & 30-1200A Heavy Duty eh<br />

4<br />

SAFETY<br />

SWITCHES<br />

30 HD 240V HFB21 b HBB21 b — HH6123 g<br />

60 GD HFB612 b HBB612 b GH223 —<br />

60 HD 240V HFB22 b HBB22 b — HH6123 g<br />

30 600V HFB612 b HBB612 — HH6123 g<br />

60 600V HFB62 b HBB62 — HH6123 g<br />

100 HFB63 b HBB63 GH223 HH6123 g<br />

200 HFB64 b HBB64 GH24 HH64 g<br />

400 HFB65 cf HBB656 HH65678 HH65678 g<br />

600 HFB66 cf HBB656 HH65678 HH65678 g<br />

800 HFB67A bf HBB67A — HH65678 g<br />

1200 HFB68 bf HBB68 — HH68 g<br />

Non-Fusible 3-Pole 60-600A General Duty & 30-1200A Heavy Duty eh<br />

30 HD HNB612 b — — HH6123 g<br />

60 GD HNB612 b — GH223 —<br />

60 HD HNB623 b — — HH6123 g<br />

100 HNB623 b — GH223 HH6123 g<br />

200 HNB64 b — GH24 HH64 g<br />

400 HNB65 cf — HH65678 HH65678 g<br />

600 HNB66 cf — HH65678 HH65678 g<br />

800 HNB67A bf — — HH65678 g<br />

1200 HNB678 f — — HH68 g<br />

Ampere Mechanism Assembly Line & Load Lugs<br />

Rating Catalog Number Catalog Number<br />

Fusible 2- and 3-Pole 60-600A General Duty<br />

& 30-1200A Heavy Duty eh<br />

30 HD 240V HM6123 g HL612 a<br />

60 GD HM6123 HL612 a<br />

60 HD 240V HM6123 g HL612 a<br />

30 600V HM6123 g HL612 a<br />

60 600V HM6123 g HL612 a<br />

100 HM6123 g HL63 a<br />

200 HM64 g HL64 a<br />

400 HM65 HL65678 d<br />

600 HM66 HL65678 d<br />

800 HM67A HL67A fi<br />

1200 HM678<br />

i<br />

Non-Fusible 3-Pole 60-600A General Duty<br />

& 30-1200A Heavy Duty eh<br />

30 HD HM6123 g HL612 a<br />

60 GD HM6123 HL612 a<br />

60 HD HM6123 g HL612 a<br />

100 HM6123 g HL63 a<br />

200 HM64 g HL64 a<br />

400 HM65 HL65678 d<br />

600 HM66 HL65678 d<br />

800 HM67A HL67A fi<br />

1200 HM678<br />

i<br />

Internal Shield Kits<br />

These kits provide an inner door on safety<br />

switches to prevent accidental contact with<br />

live parts. All kits are constructed from clear<br />

plastic, provide test probe holes and allow<br />

replacement of fuses without the removal<br />

of the kit.<br />

Catalog<br />

Number<br />

Switch<br />

Ampere<br />

Rating<br />

UPC Code<br />

040892_ _ _ _ _<br />

For use with Fusible Type 1, 3R, 12 and<br />

4X Stainless Steel Enclosed Safety<br />

Switches <br />

HSK61SSW 30 79020<br />

HSK62SSW 60 79021<br />

HSK63SSW 100 79002<br />

HSK64SSW 200 79023<br />

For use with Fusible Type VBII<br />

Disconnect Switches<br />

HSK61 30 79024<br />

HSK623 60 & 100 79025<br />

HSK64 200 79026<br />

HF362 with<br />

HSK62SSW installed<br />

VBFS361F with<br />

HSK61 Installed<br />

a Three lugs included in kit.<br />

b Includes lugs.<br />

c Lugs not included.<br />

d One lug per kit.<br />

e One per switch required unless otherwise noted.<br />

f One required per pole.<br />

g For type 4/4X stainless steel switches add “S” to end of<br />

catalog number.<br />

h For replacement door for heavy duty switches add<br />

“DOOR” to end of switch catalog number.<br />

i Lugs included with line and load bases.<br />

Not for use with Non-metallic safety switches<br />

4-36<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category HDSS


Disconnect Switches<br />

SPEEDFAX TM<br />

Section<br />

CFS Compact<br />

Fusible Switch<br />

VBFS361<br />

c o n t e n t s<br />

Compact Non-Fusible Switches<br />

Rotary Switch—Selection 5-2 – 5-3<br />

Dimensions and Wire Ranges 5-4<br />

Enclosed Rotary Disconnect Switches<br />

Enclosed Rotary Disconnect Switch—Selection 5-5<br />

Technical information 5-6<br />

Type VBII (30-600A)<br />

Features and Ordering Information 5-7<br />

Switch and Handle Selection 5-8<br />

Accessories 5-9 – 5-10<br />

Dimensions and Lug Wire Ranges 5-11<br />

Type MCS (30-200A)<br />

Switches, Fuse, and No Fuse Kit—Selection 5-12<br />

Handle Operators and Accessories 5-13<br />

Type CFS Compact Fusible Switches<br />

General information and catalog numbering system 5-14<br />

Features and ordering information 5-15<br />

Switch, shaft and handle selection 5-16<br />

Selection and accessories 5-17<br />

Technical Characteristics 5-18<br />

Type CNFS Compact Non-Fusible Switches<br />

General information and catalog numbering system 5-19<br />

Features and ordering information 5-20<br />

Switch, shaft and handle selection 5-21<br />

Additional accessories 5-22<br />

Type VB Panelboard Units<br />

General and Withstand Ratings 5-23<br />

Catalog Numbering System 5-23<br />

Vacu-Break Fusible Units—Selection 5-24 – 5-25<br />

Accessories 5-26<br />

Type HCP Switchboard Units<br />

Selection/Accessories 5-27<br />

Dimensions 5-28<br />

Type TFP Fusible Pullouts<br />

Selection/Dimensions 5-29<br />

5 DISCONNECT<br />

SWITCHES<br />

Panelboard Unit<br />

Scan to connect<br />

online to the<br />

most up-todate<br />

version of<br />

this Section of<br />

SPEEDFAX.<br />

(Section was last modified on 08/28/20)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 5-1


Disconnect Switches<br />

Compact Non-Fusible — Rotary<br />

Revised on 01/31/20<br />

Selection<br />

3LD2254-0TK51<br />

5<br />

DISCONNECT<br />

SWITCHES<br />

Features<br />

b 16–250 Ampere, to 100 hp, 480V<br />

and 600V<br />

b Rotary actuation models<br />

b 3LD2 Type switches are padlockable<br />

in the OFF position and are UL listed<br />

under File No. E47705 per UL508 and<br />

are CSA<br />

certified under File No. 203576<br />

b Base, DIN-rail and door mounting<br />

b IEC 947-1 rated, CE marked<br />

b Listed and marked “suitable as motor<br />

disconnect” per NEC Section 430-109<br />

Application<br />

Siemens Load Break Switches are listed<br />

as manual motor controllers and are<br />

suitable as motor disconnects. They are<br />

load break rated and act as enclosure<br />

discon-nects when short circuit protection<br />

is provided upstream of the switch.<br />

If upstream over current protection is not<br />

provided, use a Siemens fusible Type<br />

VBII, CFS or MCS Disconnect Switch.<br />

Ordering Information<br />

Door Mounted Switches (Rotary<br />

Type Only) — Order either complete<br />

“3LD2” assemblies components as<br />

follows:<br />

Complete Assemblies include switch,<br />

handle, and shaft. Certain 25 and 32A<br />

assemblies are also available with factory<br />

installed neutral blocks and/or aux.<br />

contacts. These accessories can also<br />

be ordered as field installed kits.<br />

Door Mounted Complete Assemblies<br />

Operator, Shaft, & Switch) 600V AC Max. b<br />

Shaft Mounted<br />

Catalog<br />

Number c<br />

Short Circuit Withstand<br />

Ratings<br />

Switch Rating<br />

and Type Max. Line Side Fuse Rating<br />

5kA with Line Side Class H, K, or<br />

RK5 Fuses<br />

25 & 32A 3LD2 80A Max. at 600V AC Max.<br />

63A 3LD2<br />

175A Max. at 600V AC Max.<br />

Note: 3LD2 switches are also rated 5kA at 600V<br />

AC Max. when protected by a 3RV motor starter<br />

with a FLA rating equal to or less than the switch<br />

ampere rating.<br />

4 Hole Mounted<br />

AC Horsepower Ratings<br />

Catalog<br />

Number c Number<br />

of Poles<br />

Ampere<br />

Rating<br />

120V<br />

1Ø<br />

240V<br />

1Ø 3Ø<br />

480V<br />

3Ø<br />

600V<br />

3Ø<br />

— 3LD2003-1TP53 a 3 16 ½ 1½ 3 7½ 10<br />

3LD2154-0TK 3LD2103-0TK 3<br />

3LD2154-1TP 3LD2103-1TP 3 a<br />

3LD2154-1TL 3LD2103-1TL 3 + N<br />

25 2 3 7½ 10 15<br />

3LD2154-2EP 3LD2103-2EP 3 + N a<br />

3LD2254-0TK 3LD2203-0TK 3<br />

3LD2254-1TL 3LD2203-1TL 3 + N<br />

32 2 3 10 20 20<br />

3LD2555-0TK 3LD2504-0TK 3 63 — 10 15 40 50<br />

— 3LD2704-0TK 3 100 — — 30 60 75<br />

— 3LD2804-0TK 3 125 — — 40 75 100<br />

a Includes auxiliary contacts (1 NO and 1 NC).<br />

b Handles are IP65 rated and are also UL listed for Type 1, 4X<br />

and 12 applications.<br />

c Add 51 for a black handle or 53 for a red & yellow handle<br />

to the end of the catalog number.<br />

5-2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category PILO


Disconnect Switches<br />

Compact Non-Fusible — Rotary<br />

Selection<br />

3LD Type Base Mounted Complete Assemblies<br />

(Operator, Shaft, & Switch) 600V AC Max.b<br />

Handle mounting b<br />

AC Horsepower Ratings<br />

Shaft<br />

(center hole)<br />

4 Hole<br />

(no defeat)<br />

4 Hole<br />

(with defeat) 120V 240V 480V 600V<br />

Catalog<br />

Catalog Number Ampere<br />

Number Catalog Number Number of Poles Rating 1Ø 1Ø 3Ø 3Ø 3Ø<br />

— 3LD2013-0TK5 3LD<strong>2017</strong>-0TK1 3<br />

— — 3LD<strong>2017</strong>-1TL1 3 + N<br />

16 ½ 1½ 3 7½ 10<br />

3LD2144-0TK5 3LD2113-0TK5 — 3<br />

3LD2144-1TL5 3LD2113-1TL5 — 3 + N<br />

25 2 3 7½ 10 15<br />

3LD2244-0TK5 3LD2213-0TK5 3LD2217-0TK1 3<br />

3LD2244-1TL53 3LD2213-1TL53 3LD2217-1TL1 3 + N<br />

32 2 3 10 20 20<br />

3LD2545-0TK5 3LD2514-0TK5 3LD2517-0TK1 3<br />

— — 3LD2517-1TL1 3 + N<br />

63 3 10 15 40 50<br />

— 3LD2714-0TK5 — 3 100 — — 30 60 75<br />

— 3LD2814-0TK5 — 3 125 — — 40 75 100<br />

— 3LD2318-0TK1 — 3 160 — — 40 75 75<br />

— 3LD2418-0TK1 — 3 250 — — 50 100 75<br />

Base Mount<br />

3LD2217-0TK13<br />

Accessories for Front Mounted 3LD2 Switches<br />

Catalog<br />

Switches<br />

Number Description Used With<br />

3LD9200-5B c 1 NO, 1 NC Aux. Contact 25-125A<br />

3LD9200-5BF c 1 NO, 1 NC Aux. with Gold Plated Contacts 25-125A<br />

3LD9220-2B Neutral/Ground Terminal 25 & 32A<br />

3LD9250-2BA Neutral/Ground Terminal 63A<br />

3LD9280-2B Neutral/Ground Terminal 100 & 125A<br />

3LD9220-0B 4th Pole (leading ON, lagging OFF) 25 & 32A<br />

3LD9250-0BA 4th Pole (leading ON, lagging OFF) 63A<br />

3LD9280-0B 4th Pole (leading ON, lagging OFF) 100 & 125A<br />

3LD9224-1B a Black Handle (4 hole mtg.) 25 & 32A<br />

3LD9284-1B a Black Handle (4 hole mtg.) 63-125A<br />

3LD9224-3B a Red/Yellow Handle (4 hole mtg.) 25 & 32A<br />

3LD9284-3B a Red/Yellow Handle (4 hole mtg.) 63-125A<br />

3LD9224-1D a Black Handle (shaft mtg.) d 25 & 32A<br />

3LD9284-1D a Black Handle (shaft mtg.) d 63-125A<br />

3LD9224-3D a Red/Yellow Handle (shaft mtg.) d 25 & 32A<br />

3LD9284-3D a Red/Yellow Handle (shaft mtg.) d 63-125A<br />

3LD9221-2A a Terminal Cover 1P (Pack of 4) 25 & 32A<br />

3LD9221-0A a Terminal Cover 3P (Pack of 4) 25 & 32A<br />

3LD9251-0A a Terminal Cover 3P (Pack of 4) 63A<br />

3LD9220-2C<br />

5 DISCONNECT<br />

SWITCHES<br />

Accessories for Base Mounted 3LD2 Switches<br />

3LD9200-5C c 1 NO, 1 NC Aux. Contact 25-250A<br />

3LD9200-5CF c 1 NO, 1 NC Aux. with Gold Plated Contacts 25-250A<br />

3LD9220-2C Neutral/Ground Terminal 25 & 32A<br />

3LD9250-2CA Neutral/Ground Terminal 63A<br />

3LD9280-2C Neutral/Ground Terminal 100 & 125A<br />

3LD9240-2C Neutral/Ground Terminal 160 & 250A<br />

3LD9220-0C 4th Pole (leading ON, lagging OFF) 25 & 32A<br />

3LD9250-0CA 4th Pole (leading ON, lagging OFF) 63A<br />

3LD9280-0C 4th Pole (leading ON, lagging OFF) 100 & 125A<br />

3LD9240-0C 4th Pole (leading ON, lagging OFF) 160 & 250A<br />

3LD9224-1B a Black Handle (4 hole mtg. no defeat) 25 & 32A<br />

3LD9284-1B a Black Handle (4 hole mtg. no defeat) 63-125A<br />

3LD9224-3B a Red/Yellow Handle (4 hole mtg. no defeat) 25 & 32A<br />

3LD9284-3B a Red/Yellow Handle (4 hole mtg. no defeat) 63-125A<br />

3LD9224-1D a Black Handle (shaft mtg.) 25 & 32A<br />

3LD9284-1D a Black Handle (shaft mtg.) 63-125A<br />

3LD9224-3D a Red/Yellow Handle (shaft mtg.) 25 & 32A<br />

3LD9284-3D a Red/Yellow Handle (shaft mtg.) 63-125A<br />

3LD9221-2A a Terminal Cover 1P (Pack of 4) 25 & 32A<br />

3LD9221-0A a Terminal Cover 3P (Pack of 4) 25 & 32A<br />

3LD9251-0A a Terminal Cover 3P (Pack of 4) 63A<br />

3LD9251-0A<br />

Note: 3LD2 shaft lengths allow the following<br />

maximum enclosure depths from the switch<br />

mounting surface to the outside of the cover:<br />

16-32A, 15.25"<br />

63-125A, 15.75"<br />

160 & 250A, 23.70"<br />

a Handles and line side terminal covers are supplied as<br />

standard with 3LD2 switches.<br />

b Add suffix 1 for a black or 3 for a red & yellow handle to the<br />

catalog number (except 3LD2244-1TL53 & 3LD2213-1TL53).<br />

Handles are IP65 rated and are also listed by UL for Type 1,<br />

4X and 12 applications.<br />

c Aux. contacts break about 30 Ms before and make about 3<br />

Ms after main switch contacts.<br />

Ratings 10A at 120V AC<br />

6A<br />

at 240V AC<br />

1.4A at 480V AC<br />

d Can be used as replacement handles on enclosed 3LD2<br />

switches.<br />

e Base mounted switches with direct mount handles<br />

are also available (3LD2330-0TK1 _ b rated 160A and<br />

3LD2430-0TK1_ b rated 250).<br />

Product Category PILO<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 5-3


Disconnect Switches<br />

Compact Non-Fusible — Rotary<br />

Revised on 01/31/20<br />

Dimensions<br />

Dimension Drawings and Wire Ranges<br />

Wire Ranges 60/75°C Cu only<br />

16A, 3LD20 (1) #18-10 AWG<br />

25A, 3LD21 (1) #14-8 AWG<br />

32A, 3LD22 (1) #14-8 AWG<br />

63A, 3LD25 (1) #14-6 AWG<br />

100, 125A, 3LD2 (1) #12-1 AWG<br />

160, 250A, 3LD2 (1) #1-400 MCM<br />

Drilling<br />

Pattern<br />

.125<br />

(3.2)<br />

.95<br />

(24.1)<br />

Dimension J Minimum Depth a<br />

Switch<br />

Dimension J<br />

3LD2 25 & 32A Front Shaft Mounted 3.07 (78)<br />

3LD2 63 Front Shaft Mounted 3.35 (85)<br />

3LD2 16-32A Front 4-hole Mounted 2.13 (54)<br />

3LD2 63A Front 4-hole Mounted 2.48 (63)<br />

3LD2 100 & 125A Front 4-hole Mounted 2.56 (65)<br />

3LD2 25 & 32A Base w/shaft Mtg. Handle 6.46 (164)<br />

3LD2 63A Base w/shaft Mtg. Handle 6.77 (172)<br />

3LD2 16-32A Base w/4-hole Mtg. Handle 5.59 (142)<br />

3LD2 63A Base w/4-hole Mtg. Handle 5.99 (152)<br />

3LD2 100-250A Base w/4-hole Mtg. Handle 6.07 (154)<br />

.877<br />

(22.5)<br />

a<br />

J<br />

C<br />

Shaft Mounted<br />

3LD2 Handle Cutout<br />

(4-hole pattern)<br />

F<br />

E<br />

A<br />

D<br />

0.16 in.<br />

(4 mm)<br />

G<br />

B<br />

5<br />

DISCONNECT<br />

SWITCHES<br />

H<br />

Switch<br />

Switch<br />

Dimensions Inches (mm)<br />

Type Catalog Number A B C D E F G H<br />

Rotary Front Mtg. 3LD20 1.89 (48) 1.97 (50) 1.97 (50) — — — — —<br />

Rotary Front Mtg. 3LD21 & 3LD22 1.81 (46) 2.17 (55) 1.97 (50) — — — — —<br />

Rotary Front Mtg. 3LD25 2.36 (60) 2.52 (64) 2.32 (59) — — — — —<br />

Rotary Front Mtg. 3LD27 & 3LD28 2.40 (61) 3.27 (83) 2.40 (61) — — — — —<br />

Rotary Base Mtg. 3LD20 1.89 (48) 1.97 (50) 2.29 (58) — — — — —<br />

Rotary Base Mtg. 3LD21 & 3LD22 1.81 (46) 2.17 (55) 2.29 (58) — — — — —<br />

Rotary Base Mtg. 3LD25 2.36 (60) 2.52 (64) 2.68 (68) — — — — —<br />

Rotary Base Mtg. 3LD27 & 3LD28 2.80 (71) 3.27 (83) 2.76 (70) — — — — —<br />

Rotary Base Mtg. 3LD23 & 3LD24 4.41 (112) 5.83 (148) 4.10 (104) — — — — —<br />

0.31 in.<br />

(8 mm)<br />

a Depth from outside of cover to back of switch.<br />

b Handle front plate dimensions:<br />

3LD 16-32A—2.64 inches square<br />

3LD 63-125—3.55 inches square<br />

5-4<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Disconnect Switches<br />

Enclosed Rotary Disconnect Switches e<br />

Description<br />

16–125A non-fusible switches are available<br />

in fiberglass reinforced polycarbonate<br />

enclosures which are UL approved as Type<br />

12 & 4X and for either indoor or outdoor<br />

use. All are horsepower and load break<br />

rated. All are panel mounted and are either<br />

supplied with factory installed aux. contacts<br />

or will accept contact kits. All are compact<br />

in size while providing ample wiring space<br />

for copper line & load conductors.<br />

Siemens Enclosed Rotary Disconnect Switches<br />

b 16–125A, Non-Fusible<br />

b 600VAC max. rated<br />

b Available in both Type 12 and 4X<br />

non-metallic enclosures<br />

b Both screw and hinged cover<br />

designs available<br />

b Listed and marked “suitable for use<br />

as motor disconnect” per NEC<br />

Section 430-109<br />

b Screw cover switches are UL listed<br />

under File No. E47705 and are CSA<br />

certified under File No. 203576<br />

b IEC 60947-3 rated and CE marked<br />

(enclosures are IP65 rated)<br />

b HP rated<br />

Revised on 08/31/20<br />

Selection<br />

b Hinged door switches are UL listed<br />

for multiple line and load conductors<br />

per phase in 30–100A ratings.<br />

They are UL & CUL listed under File<br />

No. E191706<br />

b Rotary handles are available in<br />

black, red, and yellow and in pistol<br />

grip designs<br />

b 16–63A screw cover switches have<br />

factory installed ground bars. All<br />

hinge cover switches accept ground<br />

lug kits<br />

b Screw cover switches are<br />

provided with knockouts<br />

b Padlockable in OFF position<br />

with up to (3) padlocks<br />

Catalog Number<br />

Horsepower Ratings<br />

Ampere 3 Pole, 3 Wire with (1) NO Shipping 240V AC 480V AC 600V AC<br />

Rating 3 Pole, 3 Wire & (1) NC Aux. Contact hi Weight a 1 Phase 3 Phase 3 Phase 3 Phase<br />

Non-Fusible, Type 1, 4X & 12K b with Screw Cover and Black Rotary Handle 600V AC Max. e<br />

16 3LD2064-0TB51-0US2 3LD2064-1GP51-0US2 1 1 1 ⁄2 3 7 1 ⁄2 10<br />

25 3LD2164-0TB51-0US2 3LD2164-1GP51-0US2 1 3 7 1 ⁄2 10 15<br />

30 3LD2264-0TB51-0US2 3LD2264-1GP51-0US2 1 3 7 1 ⁄2 15 20<br />

30 — 3LD2264-1TS51-0US2 f s 1 3 7 1 ⁄2 15 20<br />

30 — 3LD2264-2TW51-0US2 g s 1 3 7 1 ⁄2 15 20<br />

63 3LD2565-0TB51-0US2 3LD2565-1GP51-0US2s 3 10 15 40 50<br />

100 3LD2766-0TB51-0US2 3LD2766-1GP51-0US2s 6 — 30 60 75<br />

125 3LD2866-0TB51-0US2 3LD2866-1GP51-0US2s 6 — 40 75 100<br />

Non-Fusible, Type 1, 4X & 12K b with Screw Cover and Red and Yellow Rotary Handle 600V AC Max. e<br />

16 3LD2064-0TB53-0US2 3LD2064-1GP53-0US2 1 1 1 ⁄2 3 7 1 ⁄2 10<br />

25 3LD2164-0TB53-0US2 3LD2164-1GP53-0US2 1 3 7 1 ⁄2 10 15<br />

30 3LD2264-0TB53-0US2 3LD2264-1GP53-0US2 1 3 7 1 ⁄2 15 20<br />

30 — 3LD2264-1TS53-0US2 f s 1 3 7 1 ⁄2 15 20<br />

30 — 3LD2264-2TW53-0US2 g s 1 3 7 1 ⁄2 15 20<br />

63 3LD2565-0TB53-0US2 3LD2565-1GP53-0US2s 3 10 15 40 50<br />

100 3LD2766-0TB53-0US2s 3LD2766-1GP53-0US2s 6 — 30 60 75<br />

125 3LD2866-0TB53-0US2s 3LD2866-1GP53-0US2s 6 — 40 75 100<br />

5 DISCONNECT<br />

SWITCHES<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

a Carton quantity of (1). Shipping weight in pounds (lbs.).<br />

b Approved for indoor/outdoor use. No cover interlock provided.<br />

c 30 and 60A switches are also rated 600V AC.<br />

d Also rated as Type 12 and UL approved for both indoor and<br />

outdoor use. Defeatable cover interlock provided.<br />

e Screw cover enclosures are constructed from Makrolon 9425.<br />

Hinged cover enclosures are constructed from fiberglass reinforced<br />

polycarbonate.<br />

f Switch is supplied with (2) NO and no NC aux. contacts.<br />

g Switch is supplied with (4) NO and no NC aux. contacts.<br />

Ground bar is not provided or available.<br />

h Aux. contacts break about 3 Ms before and make about 3 Ms<br />

after main switch contacts.<br />

i 6P, 25A, switch with 1 NO & 1 NC aux. contacts and a black<br />

operating handle is also available. Order catalog number<br />

3LD2165-4VD51 (Discount Code: Pilot Devices).<br />

Product Category HDSS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 5-5


Enclosed Rotary Disconnect Switches<br />

Enclosed Rotary Disconnect Switches<br />

Revised on 08/31/20<br />

Technical information<br />

Enclosed Disconnect Switch Dimensions (Inches)*<br />

Catalog Ampere Fig. Dimensions<br />

Number Rating No. A B C D<br />

3LD2064- 16 5.52 d 3.94 3.19 4.57<br />

3LD2164- 25 5.52 d 3.94 3.19 4.57<br />

3LD2264- 30<br />

1<br />

5.52 d 3.94 3.19 4.57<br />

3LD2565- 63 6.93 e 5.75 4.10 5.87<br />

3LD2766- 100 11.90 8.35 5.36 7.13<br />

3LD2866- 125 11.90 8.35 5.36 7.13<br />

Note: 3LD2 Type switches only have top and bottom end KOs as follows:<br />

16-30A - 1/2” & 3/4”, 63A - 3/4” & 1”, 100 & 25A - 1” & 1 1/4”<br />

Figure 1<br />

Wire ranges 60/75°C Cu Only<br />

3LD2 Type Switches c<br />

16 Amps (1) #18-10 AWG<br />

25–30 Amps (1) #14-10 AWG<br />

63 Amps (1) #14-6 AWG<br />

100–125 Amps (1) #12-1 AWG<br />

HNF Type Switches<br />

(1) #14-#10 AWG Solid<br />

(1) #14-#4 AWG Stranded<br />

Up to (4) #12 AWG Solid<br />

30 Amps Up to (3) #12 AWG Stranded<br />

Up to (6) #14 AWG Stranded<br />

Up to (4) #14 AWG Stranded<br />

with (1) #10 AWG Stranded<br />

60 & 100 Amps<br />

(1) #14-#10 AWG Solid<br />

(1) #14-#1 AWG Stranded<br />

(2) #6 AWG Stranded<br />

Up to (3) #8 AWG Stranded<br />

Up to (6) #10 AWG Stranded<br />

Up to (6) #12 AWG Solid<br />

Figure 2<br />

5<br />

DISCONNECT<br />

SWITCHES<br />

UL and CUL Short Circuit Withstand Ratings<br />

Short Circuit Withstand Rating and Fuse Class<br />

With Line Side Fusing<br />

With Load Side Fusing a<br />

Ampere 5 kA at 10 kA at 18 kA at 5 kA at 18 kA at<br />

Rating 600V Max 600V Max 480V Max 480V Max 480V Max<br />

3LD2 Type Switches h<br />

RK5<br />

16<br />

(50A Max)<br />

— — — —<br />

25 & 30 RK5 (80A Max)<br />

— — — —<br />

63<br />

RK5<br />

(175A Max)<br />

— — — —<br />

100 &<br />

125<br />

—<br />

RK5<br />

(200A Max)<br />

— — —<br />

HNF Type Switches<br />

30 —<br />

Ferraz<br />

Shawmut<br />

A50P or lower<br />

H, K & RK5 H, K & RK5<br />

let-through<br />

(100A Max) (30A Max)<br />

semiconductor<br />

fuses<br />

J, T & CC<br />

(60A Max)<br />

(100A Max) Ferraz<br />

60<br />

H, K & RK5<br />

Shawmut<br />

(150A Max)<br />

A50P or lower<br />

H, K & RK5<br />

let-through<br />

(60A Max)<br />

f<br />

100 f<br />

semiconductor<br />

fuses<br />

(100A Max)<br />

IEC Fuse and Withstand Ratings<br />

Ampere Rating gG Fuse Size Short Circuit Rating<br />

3LD2 Screw Cover Switches<br />

16 20A 5k Arms<br />

25 25A 10k Arms<br />

32 50A 10k Arms<br />

63 63A 15k Arms<br />

100 100A 20k Arms<br />

125 125A 20k Arms<br />

HNF Hinged Cover Switches<br />

30 63A 10k Arms<br />

60 100A 10k Arms<br />

100 100A 10k Arms<br />

Accessories<br />

Switch<br />

Ampere Catalog<br />

Rating Number Description<br />

a For use as supplemental protection on the load side of the branch circuit over current<br />

protective device.<br />

b Ground lug kit has two lugs for #14-4 Cu/Al wire.<br />

c Factory installed ground lugs supplied as follows: 16-30A #14-10 Cu, 63A #14-8 Cu.<br />

Ground lug not provided and is not available on catalog numbers 3LD2264-2TW51-0US2<br />

and 3LD2264-2TW53-0US2.<br />

d 6.38 inches high including mounting feet.<br />

e 7.85 inches high including mounting feet.<br />

f 60 & 100A HNF switches are rated 10kA at 480V max. with line side Class H, K & RK5<br />

150A max. fuses.<br />

g Wire range (1) #14-2 AWG 60/75 °C Cu only.<br />

h 16-63A 3LD switches are also rated 5kA at 600VAC max when protected by a 3RV type<br />

MSP of the same or lesser ampere rating.<br />

*For inches / millimeters conversion, multiply inches by 25.4.<br />

3LD2 Type Switches c<br />

16–30A 3LD9220-2C Neutral Kit<br />

63A 3LD9250-2CA Neutral Kit<br />

100–125A 3LD9280-2C Neutral Kit<br />

HNF Type Switches<br />

30–100A GSGK60 Ground Lug Kit b<br />

30A LBRA1 Auxiliary Contact Kit (1 NO-1 NC)<br />

60–100A LBRA2 Auxiliary Contact Kit (1 NO-1 NC)<br />

30–100A HF63CX g Neutral Kit<br />

5-6<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Disconnect Switches<br />

Type VBII (30-600A) with Flange Mounted Operating Handle<br />

Features and Ordering Information<br />

Features<br />

b 30-600A, 600VAC and DC ratings<br />

b 240 & 600V AC switches are UL<br />

Recognized under file number<br />

E121152, Vol. 3 and CSA certified<br />

under file number 154852<br />

b 600V DC Photovoltaic switches are<br />

UL Recognized under file number<br />

E335018, Vol. 3 and are rated to<br />

switch 3 separate 600V DC circuits<br />

b Visible blade quick make and break<br />

switching action<br />

b Panel and Flange mounted assemblies<br />

facilite installation<br />

b Panel mounted switches are variable<br />

depth<br />

b Short circuit rating of 10,000 AIC with<br />

class H fuse, and of 200,000 AIC with<br />

class R or J fuses. PV switches are<br />

rated 10,000 AIC at 600V DC with<br />

600V DC rated class K, J or R fuses.<br />

b Flange mounted handles rated as Type<br />

1, 3R & 12 or 4X are padlockable in<br />

the off position with up to (3) padlocks<br />

with 5/16 hasps<br />

b Meets UL98 requirements and suitable<br />

for both main and branch circuit applications<br />

b A complete line of aux contacts are<br />

available<br />

b Load break and horsepower rated<br />

b Defeatable cover interlock standard<br />

with all handles<br />

b Meets NFPA79 requirements<br />

b Seismic qualified — complies with the<br />

2010 California Building Code (CBC)<br />

— and with the International Building<br />

Code (IBC) — Compliance Level<br />

SDS = 1.85 g<br />

5 DISCONNECT<br />

SWITCHES<br />

VBFS361, VBLK1 & VBH1<br />

VBFS363F<br />

VBNFS365, VBLK4 & VBH2<br />

Ordering Information<br />

1. Determine the ratings required (amps,<br />

volts, HP, Fusible, NF), the mounting<br />

needed (Panel or Flange), and select<br />

the appropriate switch.<br />

2. For panel mounted switches with a<br />

rigid operating shaft (30-600A), order<br />

panel mounted switch, flange mounted<br />

operating handle & rigid linkage kit<br />

based on depth required.<br />

3. For panel mounted switches with a<br />

Max-Flex operator, order panel mounted<br />

switch, Max-Flex Handle & Adapter<br />

Kit and drive cable.<br />

4. Select accessories if required.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 5-7


Disconnect Switches<br />

Type VBII (30-600A) with Flange Mounted Operating Handle<br />

Selection<br />

Switches—for Standard 600V Max AC or DC Applications<br />

5<br />

DISCONNECT<br />

SWITCHES<br />

Horsepower Rating, Switches and 3-Phase d<br />

Switch Max. AC<br />

600<br />

Ampere Voltage Catalog<br />

240 Volts AC 480 Volts AC 600 Volts AC<br />

Volts DC<br />

Rating Rating Number Standard Max. Standard Max. Standard Max. (max) d<br />

Fusible Panel Mounted Variable Depth Switches - 3-Pole e<br />

30 240 VBFS321 3 7 1/2 — — — — — a<br />

60 240 VBFS322 7 1/2 15 — — — — — b<br />

30 600 VBFS361 — — 5 15 7 1/2 20 15 c<br />

60 600 VBFS362 — — 15 30 15 50 30 c<br />

100 600 VBFS363 — — 25 60 30 75 50 c<br />

200 600 VBFS364 — — 50 125 60 150 50<br />

400 600 VBFS365 — — 100 250 125 350 — <br />

600 600 VBFS366 — — 150 400 200 500 — <br />

Non-fusible Panel Mounted Variable Depth Switches - 3-Pole e<br />

30 600 VBNFS361 — 10 — 20 — 30 15 c<br />

60 600 VBNFS362 — 20 — 50 — 60 30 c<br />

100 600 VBNFS363 — 40 — 75 — 100 50 c<br />

200 600 VBNFS364 — 60 — 125 — 150 50<br />

400 600 VBNFS365 — 125 — 250 — 300 — <br />

600 600 VBNFS366 — 200 — 400 — 500 — <br />

Fusible Flange Mounted Switches - 3-Pole <br />

30 240 VBFS321F 3 7 1/2 — — — — — a<br />

60 240 VBFS322F 7 1/2 15 — — — — — b<br />

30 600 VBFS361F — — 5 15 7 1/2 20 15 c<br />

60 600 VBFS362F — — 15 30 15 50 30 c<br />

100 600 VBFS363F — — 50 60 30 75 50 c<br />

200 600 VBFS364F — — 100 125 60 150 50<br />

Non-fusible Flange Mounted Switches – 3-Pole <br />

30 600 VBNFS361F — 10 — 20 — 30 15 c<br />

60 600 VBNFS362F — 20 — 50 — 60 30 c<br />

100 600 VBNFS363F — 40 — 75 — 100 50 c<br />

200 600 VBNFS364F — 60 — 125 — 150 50<br />

Note: Fusible switches include fuse provisions for Class H Fuses. The load base can be moved to pre-drilled holes for Class J Fuses on all 600V switches. If Class R<br />

Fuses are required, add a Class R Fuse Clip Kit.<br />

Switches—for Photovoltaic Applications, 600VDC Max. <br />

(for use in negative ground systems only)<br />

Switch<br />

Ampere<br />

Rating<br />

Catalog Number<br />

Rated Isc per NEC<br />

Article 690<br />

Fusible Panel Mounted Variable Depth Switches—3 Pole <br />

30 VBFS361PV 19.2A<br />

60 VBFS362PV 38.4A<br />

100 VBFS363PV 64.0A<br />

Non-Fusible Panel Mounted Variable Depth Switches—3 Pole <br />

30 VBNFS361PV 24.0A<br />

60 VBNFS362PV 48.0A<br />

100 VBNFS363PV 80.0A<br />

Fusible Flange Mounted Variable Depth Switches—3 Pole<br />

(Includes Type 1, 3R and 12 Rated Operating Handle) <br />

30 VBFS361FPV 19.2A<br />

60 VBFS362FPV 38.4A<br />

100 VBFS363FPV 64.0A<br />

Non-Fusible Flange Mounted Variable Depth Switches—3 Pole<br />

(Includes Type 1, 3R and 12 Rated Operating Handle) <br />

30 VBNFS361FPV 24.0A<br />

60 VBNFS362FPV 48.0A<br />

100 VBNFS363FPV 80.0A<br />

Cable Kit<br />

For use with 30-200A panel mounted switches and Max-Flex<br />

handle and adapter kit.<br />

Catalog Number<br />

FHOEC036<br />

FHOEC048<br />

Description<br />

36" long drive cable<br />

48" long drive cable<br />

Max-Flex TM Handle and Adapter Kit<br />

(Type 1, 12, 3R & 4X) Use with 30-200A panel mounted<br />

switches and cable kit.<br />

Catalog Number<br />

Operating Handle Description<br />

Plastic Handles<br />

VBHM1<br />

30-200A Type 1, 3R, 12 and 4X<br />

Metal Handles<br />

VBHM2 30-200A Type 1, 3R and 12<br />

VBHM2X<br />

30-200A Type 4X<br />

a Rated 5 HP at 250V DC.<br />

b Rated 10 HP at 250V DC.<br />

c 600V DC & 600V DC horsepower rating shown requires (2) poles to be connected<br />

in series.<br />

d Std. - applies when non-time delay fuses are used.<br />

Max. - applies when time delay fuses are used.<br />

e Includes line base, load base, operating mechanism and line and load lugs.<br />

Order operating handle and linkage kits from tables on pages 5-8 or 5-9.<br />

f Includes line base, load base, operating mechanism line and load lugs plastic<br />

operating handle and required linkage.<br />

g All photovoltaic switches are rated to be used with<br />

3 separate 600V DC circuits.<br />

h Fusible switches accept Class K or R fuses as standard and Class J fuses by<br />

relocating the load base.<br />

Rated 250V DC max and 50HP at 250V DC.<br />

Please add letter "M" to the end of catalog number for metal handle.<br />

VBNFS361,<br />

VBHM1 &<br />

FHOEC036<br />

5-8<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category HDSS


Disconnect Switches<br />

Type VBII (30-600A) with Flange Mounted Operating Handle<br />

Selection & Accessories<br />

Flange Mounted Operating Handles<br />

For use with Panel Mounted Switches.<br />

Plastic handle is included with Flange<br />

Mounted Switches as standard.<br />

Catalog<br />

Number Operating Handle Description<br />

Plastic Handles<br />

VBH1 30-200A Type 1, 3R & 12<br />

VBH14X 30-200A Type 4X<br />

Metal Handles<br />

VBH112 30-200A Type 1, 3R & 12<br />

VBH14 30-200A Type 4X<br />

VBH2 400A Type 1 & 12<br />

VBH2R 400 & 600A Type 1, 3R & 12<br />

VBH24X 400 & 600A Type 4X<br />

Rigid Linkage Kits<br />

For use with Panel Mounted Switches.<br />

Not required for Flange Mounted<br />

Switches.<br />

Switch<br />

Catalog Ampere Enclosure Depth <br />

Number Rating Min Max.<br />

VBLK1 30-200 6.94 6.94 <br />

VBLK2 30-200 6.94 19.0<br />

VBLK3 400 & 600 9.00 8.75<br />

VBLK4 400 & 600 9.00 19.0<br />

NEW<br />

Quick Connects<br />

They provide two point control power<br />

take-off capability and are normally<br />

used on two poles on the line side<br />

when it is required to have control<br />

power available when the switch is<br />

in the OFF position. They provide a<br />

mounting provision for standard ¼”<br />

quick connect terminal. Installed in<br />

the line or load side. 30A VBII switches<br />

have lugs UL listed to accept (2) wires<br />

per pole as standard so a 30A kit is<br />

not required.<br />

Catalog<br />

Number<br />

Description<br />

HCQ62<br />

60A 2 wire quick connect kit<br />

HCQ63<br />

100A 2 wire quick connect kit<br />

HCQ64<br />

200A 2 wire quick connect kit<br />

HT63<br />

HR612<br />

Class R Fuse Clip Kits<br />

These kits prevent the installation of<br />

Class H and K fuses (one kit required per<br />

switch).<br />

Class R Fuse Clip Kits<br />

Catalog<br />

Number<br />

HR21<br />

HR612<br />

HR62<br />

HR63<br />

HR64<br />

HR656<br />

Internal Door Latch Kits<br />

For use with enclosures with door<br />

mounted latching bar. Required when a<br />

flange mounted switch is mounted in a<br />

Hoffmann or Rittal enclosure provided<br />

with an AB cutout.<br />

Catalog<br />

Number<br />

DKR2<br />

DKR3<br />

Description<br />

30A, 240V Kit (HD only)<br />

30A, 600V Kit/60A, 240V Kit<br />

60A, 600V Kit<br />

100A Kit<br />

200A Kit<br />

400A/600A Kit<br />

Description<br />

2 point (for use with<br />

enclosures less than 40" high)<br />

3 point (for use with<br />

enclosures 40" or larger<br />

in height)<br />

Class T Fuse Adapter Kits<br />

100-600A fusible switches are field<br />

convertible to accept Class T fuses.<br />

400-600A switches are field convertible<br />

to accept Class T fuses by moving the<br />

load base to a pre-drilled T fuse position.<br />

Class T Fuse Adapter Kits <br />

Catalog<br />

Number Description<br />

HT23 100A, 240V Kit<br />

HT63 100A, 600V Kit<br />

HT24 200A, 240V Kit<br />

HT64s 200A, 600V Kit<br />

Class J Fuse Provisions<br />

All 30-600A, 600V fusible switches are<br />

field convertible to accept Class J fuses<br />

by moving the load base to a pre-drilled<br />

J fuse position.<br />

Window Kits (Type 1, 12, 3R and 4x)<br />

Allows viewing of visible blades and of<br />

indicating fuses through 200A.<br />

Catalog<br />

Number<br />

VBWK1<br />

VBWK2<br />

VBWK3<br />

Description<br />

30A Window Kit<br />

60 & 100A Window Kit<br />

200-600A Window Kit<br />

HN612<br />

Neutral Kits <br />

Standard Neutral Kits can be field<br />

installed in 30-100A switches.<br />

Neutral Kits<br />

Switch<br />

Kit Catalog<br />

Ampere Rating<br />

Number<br />

30A 600V, 60A 240V HN612<br />

60A, 600V & 100A HN623<br />

200% Neutral Kits <br />

UL listed 200% Neutrals are available<br />

on 60 & 100A switches. They are typically<br />

used with non-linear transformers<br />

or where increased neutral ampacity/lug<br />

capacity is required.<br />

200% Neutral Kits<br />

Switch<br />

Ampere Kit Catalog Wire Range Line &<br />

Rating Number Load Lugs (Cu/Al)<br />

60 & 100A HN263 (2) #14-1/0 AWG<br />

5 DISCONNECT<br />

SWITCHES<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

Dimensions (min. & max.) from enclosure mounting pan<br />

to outside surface of enclosure handle mounting flange.<br />

7.12 for 200A switches.<br />

One kit per pole required.<br />

UL approved (not CSA certified).<br />

Product Category HDSS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 5-9


Disconnect Switches<br />

Type VBII (30-600A) with Flange Mounted Operating Handle<br />

Accessories<br />

5<br />

DISCONNECT<br />

SWITCHES<br />

HA161234<br />

HA261234<br />

Auxiliary Contacts<br />

The auxiliary contacts are available in 1 normally open and 1 normally closed<br />

or 2 normally open and 2 normally closed configurations. Siemens offers a<br />

PLC Auxiliary Switch (30-200A) that has very low resistance for low voltage<br />

and current typical in PLC circuits. All auxiliary contacts make after and break<br />

before main switch contacts.<br />

Switch<br />

Kit Ampere Rating<br />

Kit Horsepower Rating<br />

Ampere Aux. Switch 125V AC 250V AC 28V DC 125V AC 250V AC 28V DC<br />

Rating Catalog Number Max. Max. Max. Max. Max. Max.<br />

With 1 NO & 1 NC Isolated Contacts<br />

30-200 HA161234 10 10 — 1/2 3/4 —<br />

400-600 HA165678 10 10 — 1/2 3/4 —<br />

With 2 NO & 2 NC Isolated Contacts<br />

30-200 HA261234 10 10 7 1/2 3/4 —<br />

400-600 HA265678 10 10 7 1/2 3/4 —<br />

Low Current PLC Type with 1 NO & 1 NC Gold Plated Contacts<br />

30-200 HA361234 10 10 — 1/2 3/4 —<br />

400-600 HA365678 10 10 — 1/2 3/4 —<br />

Fuse Puller Kits<br />

Fuse Puller Kits are field installable in 30-100A Type VBII Heavy Duty<br />

Switches (one kit required per 3-pole switch).<br />

Switch<br />

Ampere Fuse Puller Kit<br />

Rating Catalog Number<br />

030 HP61<br />

060 HP62s<br />

100 HP63s<br />

HP61<br />

Copper Lug Kits<br />

All switches are UL approved to accept field installed copper lug kits.<br />

Switch Copper Lug<br />

Ampere Catalog<br />

Rating Number Description<br />

30–60 HLC612 (9) Lugs/Kit #14-4 AWG Cu<br />

100 HLC63s (9) Lugs/Kit #14-1/0 AWG Cu<br />

200 HLC64s (9) Lugs/Kit #6 AWG-300 Kcmil Cu<br />

400–600A HLC65678 (1) Lugs/Kit #1/0 AWG-600 Kcmil Cu<br />

HLC612<br />

Equipment Ground Kits<br />

Equipment Ground Lug Kits are available for all switches.<br />

Switch<br />

Ampere Catalog Number of Wire Range<br />

Rating Number Terminals Per Terminal (Cu/Al)<br />

30–200 HG61234 2 #14-4 AWG<br />

400 & 600 HG656 4 #6 AWG-250 Kcmil<br />

NEW Internal Shield Kits (for fusible switches)<br />

Kits provide a “skirt” that encloses the VBII switch and also a clear plastic<br />

inner door to prevent accidental contact with live parts. Test probe holes<br />

are provided and fuses can be replaced without removal of kit.<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

HSK61<br />

Switch<br />

Shield Kit<br />

Ampere Rating Catalog Number<br />

30A<br />

HSK61<br />

60-100A HSK623<br />

200A<br />

HSK64<br />

5-10<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category HDSS


Disconnect Switches<br />

Type VBII (30-600A) with Flange Mounted Operating Handle<br />

Lug Wire Ranges & Dimensions<br />

Lugs<br />

30 & 60A switches are suitable for use with 60° or 75°C wire. 100–600A<br />

switches are suitable for use with 75°C rated wire. All switches are supplied<br />

with factory installed line and load lugs.<br />

Wire Ranges (Line, Load and Standard Neutral)<br />

Switch<br />

Ampere<br />

Rating UL Approved Wire Range Lug Wire Range<br />

30 #14-6 AWG (Cu/AI) #14-2 AWG (Cu/Al)<br />

60 #14-2 AWG (Cu/AI) #14-2 AWG (Cu/Al)<br />

100 #14-1/0 AWG (Cu/Al) #14-1/0 AWG (Cu/Al)<br />

200 #6 AWG-300 Kcmil (Cu/Al) #6 AWG-300 Kcmil (Cu/Al)<br />

400 1/0 AWG-750 Kcmil (Cu/Al) or (1) 1/0 AWG-750 Kcmil (Cu/Al) or<br />

(2) 1/0 AWG-250 Kcmil (Cu/Al) (2) 1/0 AWG-250 Kcmil (Cu/Al)<br />

600 (2) 1/0 AWG-750 Kcmil (Cu/Al) or (2) 1/0 AWG-750 Kcmil (Cu/Al) or<br />

(4) 1/0 -250 Kcmil (Cu/Al) (4) 1/0 AWG-250 Kcmil (Cu/Al)<br />

Approximate Dimensions<br />

Mounting bracket shown with handle installed is supplied with<br />

Flange Mounted Switches only. All Panel Mounted Switches<br />

have a “L” shaped mounting pan with a line base, load base<br />

(if fusible) and mechanism installed.<br />

Dimensions<br />

Catalog Number A B C a D (min) D (max)<br />

Fusible, Panel Mounted<br />

VBFS321 11.88 N/A 7.47 6.94 19<br />

VBFS322 13.12 N/A 8.50 6.94 19<br />

VBFS361, VBFS361PV 11.88 N/A 7.47 6.94 19<br />

VBFS362, VBFS362PV 13.12 N/A 8.50 6.94 19<br />

VBFS363, VBFS363PV 13.12 N/A 8.50 6.94 19<br />

VBFS364 17 N/A 12.33 7.12 19<br />

VBFS365 26.25 N/A 16.50 8.63 19<br />

VBFS366 26.25 N/A 16.50 8.63 19<br />

Non-fusible, Panel Mounted<br />

VBNFS361, VBNFS361PV 9.79 N/A 7.47 6.94 19<br />

VBNFS362, VBNFS362PV 9.79 N/A 8.50 6.94 19<br />

VBNFS363, VBNFS363PV 9.79 N/A 8.50 6.94 19<br />

VBNFS364 10.77 N/A 12.33 7.12 19<br />

VBNFS365 13 N/A 16.50 8.63 19<br />

VBNFS366 13 N/A 16.50 8.63 19<br />

Fusible, Flange Mounted<br />

VBFS321F 11.88 14.08 7.47 7.27 N/A<br />

VBFS322F 13.12 15.83 8.85 7.27 N/A<br />

VBFS361F, VBFS361FPV 11.88 14.08 7.47 7.27 N/A<br />

VBFS362F, VBFS362FPV 13.12 15.83 8.85 7.27 N/A<br />

VBFS363F, VBFS363FPV 13.12 15.83 8.85 7.27 N/A<br />

VBFS364F 17 18.20 12.68 7.57 N/A<br />

Non-fusible, Flange Mounted<br />

VBNFS361F, VBNFS361FPV 9.79 11.78 7.47 7.27 N/A<br />

VBNFS362F, VBNFS362FPV 9.79 11.78 8.85 7.27 N/A<br />

VBNFS363F, VBNFS363FPV 9.79 11.78 8.85 7.27 N/A<br />

VBNFS364F 10.77 11.97 12.68 7.57 N/A<br />

D<br />

A<br />

C<br />

5 DISCONNECT<br />

SWITCHES<br />

a Dimension C for panel mounted switches indicates the minimum width from the left<br />

hand edge of the switch mounting pan to the right hand inside surface of the enclosure.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 5-11


Disconnect Switches<br />

Type MCS (30-200A) — Switches, Fuse and No Fuse Kits<br />

Selection<br />

Features<br />

b 30, 60, 100 and 200 Ampere Switches<br />

b UL Recognized (file # E121152 vol. 1 &<br />

2) and CSA Certified<br />

b Simple Mounting — with an integral<br />

switch and over center mechanism<br />

b Horsepower & load break rated<br />

b Compact Size<br />

b Visible Blade Contacts<br />

b Rugged Construction — with a short<br />

circuit current rating of 10,000 amps<br />

with Class H or 200,000 amps at 600V<br />

maximum AC, when fused with Class<br />

R or Class J fuses<br />

b Available with three operator handle<br />

options, allowing flexible placement<br />

of switch<br />

b Field Installable Auxiliary Contacts<br />

b Flexible Fuse Class Configurations<br />

b Flange mounted handles meet NFPA79<br />

requirements<br />

5<br />

DISCONNECT<br />

SWITCHES<br />

Type MCS Disconnect Switch with<br />

Max-Flex handle operator<br />

Ordering Information<br />

1. Select the basic switch size you need<br />

(30, 60, 100 or 200 ampere).<br />

2. Check the switch selected against the<br />

maximum horsepower rating required<br />

for our application. “L” or “R” suffix on<br />

Type MCS Disconnect Switch with<br />

fixed-depth, flange-mounted handle<br />

switch catalog numbers denotes left or<br />

right-handed mechanism drive.<br />

3. Choose either fuse or no fuse kit from<br />

chart below. Information<br />

4. Check “Minimum Dimensions” on page<br />

Type MCS Disconnect Switch with<br />

rotary handle<br />

5-13 for installation space requirements.<br />

5. Select from the list of handle operators,<br />

the type which best suits your<br />

application. Handle operators can be<br />

selected from the next page.<br />

Basic Switches<br />

Maximum Horsepower Rating, 3 Phase d<br />

Catalog Catalog<br />

240 Volts AC 480 Volts AC 600 Volts AC<br />

250<br />

Switch Maximum Number Number Time Time Time Volts<br />

Ampere Voltage Right Left Standard Delay Standard Delay Standard Delay DC<br />

Rating Rating Hand Hand Fuse Fuse Fuse Fuse Fuse Fuse (max) d<br />

130 600 MCS603R MCS603L 13 17 1 ⁄2 15 115 17 1 ⁄2 120 15<br />

160 600 MCS606R MCS606L 17 1 ⁄2 15 15 130 15 150 10<br />

100 600 MCS610R MCS610Ls 15 30 25 160 30 175 20<br />

200 600 MCS620R MCS620Ls 25 60 50 125 60 150 40<br />

Fuse And No Fuse Kits (Includes load base plus line and load fuse clips) a<br />

Basic<br />

Switch<br />

Ampere<br />

Rating<br />

130<br />

160<br />

100<br />

200<br />

Switch<br />

Catalog<br />

Number<br />

MCS603R<br />

or<br />

MCS603L<br />

MCS606R<br />

or<br />

MCS606L<br />

MCS610R<br />

or<br />

MCS610L<br />

MCS620R<br />

or<br />

MCS620L<br />

Kit<br />

Description<br />

No Fuse Kits For Class H For Class J For Class R<br />

Standard Cu Only b Catalog Catalog Catalog<br />

Catalog Number Catalog Number Number a Number a Number a<br />

No Fuse TMK606 — — — —<br />

30A, 250V — — FCK203s — FCRK203 #14 to<br />

30A, 600V — — FCK206 FCJK603 FCRK206 #4 AWG<br />

60A, 250V — — FCK206 — FCRK206 Cu/AI<br />

60A, 600V — — FCK606 FCJK606 FCRK606<br />

No Fuse TMK606 — — — —<br />

60A, 250V — — FCK206 — FCRK206 #14 to<br />

60A, 600V — — FCK606 FCJK606 FCRK606 #4 AWG<br />

100A, 250V — — OFCK661s OFCK661s<br />

c<br />

Cu/AI<br />

100A, 600V — — OFCK661s OFCK661s<br />

c<br />

No Fuse TMK610 TMK610C — — —<br />

100A, 250V — — FCK610 FCK610<br />

c<br />

#14 to<br />

100A, 600V — — FCK610 FCK610<br />

c<br />

#2/0 AWG<br />

200A, 250V — — OFCK620 OFCK620<br />

c<br />

Cu/AI<br />

200A, 600V — — OFCK620 OFCK620<br />

c<br />

No Fuse TMK620 TMK620Cs — — — #6 to<br />

200A, 250V — — FCK620 FCK620<br />

c<br />

300 kcmil<br />

200A, 600V — — FCK620 FCK620<br />

c<br />

Cu/AI<br />

Lug<br />

Wire<br />

Size<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

a For “copper only” connectors, order as follows:<br />

Fusible—order standard switch, standard fuse kit and copper<br />

only no fuse kit.<br />

Non-Fusible—order standard switch and copper only no<br />

fuse kit.<br />

b Includes both line and load lugs.<br />

c For Class R fuses order Class H kit from this table and the<br />

Class R conversion kit from the next page.<br />

d HP ratings for time delay fuses and for 250V DC also<br />

apply to Non-fusible switches.<br />

5-12<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category HDSS


Disconnect Switches<br />

Type MCS (30-200A)<br />

Accessories<br />

Auxiliary Switch Kits<br />

Contact Arrangement<br />

Switch<br />

Catalog Number<br />

MCS Disconnect Switch Panel Space Requirements<br />

Panel Space Requirements<br />

1 NO/1 NC<br />

Catalog Number<br />

2 NO/2 NC<br />

Catalog Number<br />

MCS603R MCSAKR136 MCSAKR236<br />

MCS603L MCSAKL136 MCSAKL236s<br />

MCS606R MCSAKR136 MCSAKR236<br />

MCS606L MCSAKL136 MCSAKL236s<br />

MCS610R MCSAK116 MCSAK216<br />

MCS610L MCSAK116 MCSAK216<br />

MCS620R MCSAK126 MCSAK226<br />

MCS620L MCSAK126 MCSAK226<br />

Handle Operators<br />

Fixed Depth, Flange Mounted, Types 1, 3, 3R, 12 af<br />

Minimum Dimensions (inches*)<br />

Switch<br />

Catalog<br />

Fuse<br />

Class R Fuse Conversion Kits<br />

Fuse Clip Rating Catalog Number<br />

100A, 600V SSRK33<br />

200A, 600V SSRK34<br />

Fuse Ejector Kits<br />

Switch<br />

Catalog Number<br />

MCS610<br />

MCS620<br />

Switch<br />

Complete Handle Mechanism Handle Only Switch Operator Only<br />

Catalog Number Catalog Number Catalog Number Catalog Number<br />

MCS603R FDFS06R FDH10 FDS06R<br />

MCS603L FDFS06L FDH10 FDS06L<br />

MCS606R FDFS06R FDH10 FDS06R<br />

MCS606L FDFS06L FDH10 FDS06L<br />

MCS610R FDFS06R FDH10 FDS06R<br />

MCS610L FDFS06L FDH10 FDS06L<br />

MCS620R FDFS20R FDH20 FDS20R<br />

MCS620L FDFS20L FDH20 FDS20L<br />

Variable Depth, Flange Mounted Max-Flex , Types 1, 3, 3R, 12 b<br />

Number Size “A” “B” “C” Class<br />

30A/240V 6.13 5.52 8.11 H, K, R<br />

MCS603 30A/600V 6.13 5.52 10.11 H, K, R<br />

30A/600V 6.13 5.52 8.48 J<br />

60A/240V 6.13 5.52 7.86 H, K, R<br />

MCS606 60A/600V 6.13 5.52 10.38 H, K, R<br />

60A/600V 6.13 5.52 8.35 J<br />

100A/240V 7.38 7.59 11.85 H, K, R<br />

MCS610 100A/600V 7.38 7.59 13.85 H, K, R<br />

100A/600V 7.38 7.59 10.6 J<br />

200A/240V 9.17 9.00 14.7 H, K, R<br />

MCS620 200A/600V 9.17 9.00 17.2 H, K, R<br />

200A/600V 9.17 9.00 13.32 J<br />

Fuse Ejector Kit<br />

Catalog Number<br />

FE100s<br />

FE200s<br />

Switch<br />

Complete Handle Mechanism Handle Only Switch Operator Only Cable Only c<br />

Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number<br />

MCS603R FHOS06036R FHOHS FHOS06R FHOEC036<br />

MCS603L FHOS06036L FHOHS FHOS06L FHOEC036<br />

MCS606R FHOS06036R FHOHS FHOS06R FHOEC036<br />

MCS606L FHOS06036L FHOHS FHOS06L FHOEC036<br />

MCS610R FHOS06036R FHOHS FHOS06R FHOEC036<br />

MCS610L FHOS06036L FHOHS FHOS06L FHOEC036<br />

MCS620R FHOS20036R FHOHS FHOS20R FHOJC036<br />

MCS620L FHOS20036L FHOHS FHOS20L FHOJC036<br />

Variable Depth Rotary, Through-The-Door-Mounted, Types 1, 12 de<br />

Variable Depth<br />

Shaft Only Variable Depth<br />

MCS603R CRHOS06VD CRHOH RHOS06 RHOSVD<br />

MCS606R CRHOS06VD CRHOH RHOS06 RHOSVD<br />

MCS610R CRHOS06VD CRHOH RHOS06 RHOSVD<br />

MCS620R CRHOS20VD RHOH RHOS20 RHOSVD<br />

“A” – Dimension is measured from each<br />

cross bail pin.<br />

“B” – Dimension is measured from line<br />

side barrier to load side barrier.<br />

“C” – Dimension is measured from line<br />

side terminal of switch to load side<br />

terminal of fuse load base.<br />

5 DISCONNECT<br />

SWITCHES<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

aFor Type 4 and 4X applications, order handle only<br />

Catalog Number<br />

100A - FDH104 200A - FDH204<br />

bFor Type 4 and 4X applications, order handle only<br />

Catalog Number FHOHS4<br />

cStandard cable length is 36 inches. Alternate lengths are<br />

available as follows:<br />

Length Amps Cat. No.<br />

48" 30–100 FHOEC048<br />

60" 30–100 FHOEC060<br />

48" 200 FHOJC048<br />

60" 200 FHOJC060<br />

dFor Type 4 and 4X applications, order handle only<br />

Catalog Number RHOH4<br />

eFor Type 3 and 3R applications, order handle only<br />

Catalog Number RHOH<br />

f Min. enclosure depth from mounting pan to handle mounting<br />

surfaces: 30-100A 6.44 Inches<br />

200A 10.93 Inches<br />

*For millimeters multiply inches by 25.4.<br />

Product Category HDSS & MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 5-13


Disconnect Switches<br />

Type CFS Switches, Shafts and Handles<br />

Revised on 01/31/20<br />

General Information<br />

Type CFS Compact Fusible Switches<br />

5<br />

DISCONNECT<br />

SWITCHES<br />

Description<br />

Siemens Type CFS compact fusible switches meet UL 98<br />

requirements and can be used in either service entrance<br />

or branch circuit applications. 30-800A, 3 pole switches are<br />

offered and are all rated 600V AC maximum. 30A switches<br />

are available with provisions for either Class CC or J fuses.<br />

60A and larger switches provided with Class J fuse provisions<br />

can be used in non-fusible applications with field installable<br />

no-fuse kits.<br />

All are open style, designed to be panel mounted and are<br />

UL listed under file number #E121152 or #E68312 and<br />

CSA certified under file number #222227. A variety of door<br />

mounted rotary operators are available with Type 1, 3R, 12<br />

or 4/4X ratings.<br />

NFPA79 Kits<br />

CFSNFPA1 AND CFSNFPA2N kits provide an internal handle<br />

and padlocking means to comply with article 5.3.4.2 of the<br />

NFPA-2002 standard.<br />

Catalog Numbering System<br />

CFS Switches<br />

Compact Fusible Switch<br />

• Number of poles 3 = 3<br />

CFS 3 6 1 J 5 N<br />

• Max. Voltage Rating 6 = 600V<br />

• Ampere rating<br />

1 = 30A<br />

2 = 60A<br />

3 = 100A<br />

4 = 200A<br />

5 = 400A<br />

6 = 600A<br />

7 = 800A<br />

• Fuse provisions type<br />

C = Class CC<br />

J = Class J with right hand mechanism<br />

JL = Class J with left hand mechanism<br />

L = Class L with right hand mechanism<br />

• Max. AIC rating<br />

5 = 100kA<br />

Omit = 200kA J fused<br />

• Version<br />

N = New size reduced version<br />

N1 = New 100kA 60A switch<br />

Operating Handles<br />

CFS type handle<br />

• Shaft cross section<br />

5 = 5 mm<br />

10 = 10 mm<br />

12 = 12 mm<br />

• Handle color and length<br />

B = Black & blue, short<br />

R = Red & yellow, short<br />

BL = Black & blue, long<br />

RL = Red & yellow, long<br />

• NEMA type<br />

12 = 1, 3R and 12<br />

4 = 1, 3R, 12 and 4/4X<br />

• Version<br />

N = New version<br />

CFSH 10 R 12 N<br />

CFS Operating Shafts<br />

CFS type shaft<br />

• Shaft cross section<br />

5 = 5 mm<br />

10 = 10 mm<br />

12 = 12 mm<br />

• Shaft length<br />

200 = 200 mm<br />

400 = 400 mm<br />

• Switch compatibility<br />

Omit = 30A, 100kA<br />

H = 100 or 200 kA<br />

• Version<br />

N = New version<br />

CFSS 10 200 H N<br />

5-14<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Disconnect Switches<br />

Type CFS Compact Fusible Switches<br />

Revised on 01/31/20<br />

Features and Ordering Information<br />

Features<br />

• 30 - 800A ratings<br />

• UL Listed under file #E121152<br />

& CSA Certified under file #222227<br />

• Door mounted rotary handles with defeatable cover interlock<br />

• Meets UL requirements for both main and branch circuit<br />

applications<br />

• Compact size<br />

• 100kA with Class CC fuses or up to 200kA with<br />

Class J fuses<br />

• Load break and horsepower rated<br />

• Quick make and break operation<br />

• All handles are padlockable with up to (3) padlocks with<br />

5/16” hasps in the OFF position<br />

• Catalog numbers CFS361C5 & CFS361J5 can be DIN-rail<br />

mounted and can be either front or side operated with<br />

standard rotary handles..<br />

• All CFS part numbers ending in N can be either front or<br />

side operated with standard rotary handles.<br />

• Handles are available in Type 1, 3R, 4/4X & 12 ratings<br />

• NFPA 79 field installed kits are available<br />

• 30-400A, 200kA switches are provided with quick connect<br />

terminal provisions for voltage sensing or for 10A max.<br />

control circuits<br />

Switch Shaft Handle Lugs/Accessories<br />

5 DISCONNECT<br />

SWITCHES<br />

CFS363JN<br />

with (2) CFSAUX1NO CFSS10200HN CFSH10BL12N CFSL200<br />

Ordering information<br />

1. Select the panel mounted switch required based on<br />

Ampere, HP and AIC requirements. Switches with a right<br />

hand mechanism are standard, 30-100A switches with a<br />

left hand mechanism are available.<br />

2. Select handle based on environmental rating required.<br />

3. Select operating shaft (200 or 400mm in length). For enclosure<br />

depths of 9.0” or less from panel mounting surface to<br />

inside of door use 200mm long shafts. For deeper enclosures<br />

use 400mm long shafts. 30A 100kA switches can be<br />

used in 10” deep enclosures (panel to inside of door) with<br />

200mm shaft and CFSH5N handles.<br />

Note: Be sure to check shaft and handle compatibility with<br />

the switch selected by using information provided in the<br />

selection tables.<br />

4. Line & load lugs are provided as standard on 30-100A<br />

switches. Terminal kits are available for 200-800A switches<br />

if needed.<br />

5. Auxiliary contact are available if needed as follows.<br />

30A switch CFS361J5 will accept up to (2) aux contacts<br />

without an aux contact holder. If more than (2) aux contacts<br />

are required order aux contacts PLUS aux contact holder<br />

kit CFSAUXH1. All other switches will accept up to (4) aux<br />

contacts.<br />

6. 30-100A switches are designed to prevent inadvertent<br />

contact with live parts and shields are not required. 200 &<br />

400A switches are not supplied with terminal shields. They<br />

are available as field installed kits for both line and load<br />

terminals. 400-800A switches are supplied as standard with<br />

line shields and terminal shroud kits are available for the<br />

load side.<br />

Product Category HDSS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 5-15


Disconnect Switches<br />

Type CFS Compact Fusible Switches<br />

Revised on 01/31/20<br />

Shaft and Handle Selection<br />

Fusible switches, 3-pole 600V AC Max. 30-100A & 600-800A switches<br />

are also rated 250V DC Max when poles are field connected in series e<br />

Switch<br />

Ampere<br />

Rating<br />

Catalog<br />

Number<br />

Fuse<br />

Provisions<br />

Provided<br />

Max Horsepower Ratings<br />

240V<br />

3Ø AC<br />

480V<br />

3Ø AC<br />

600V<br />

3Ø AC<br />

250V<br />

DC<br />

AC Short<br />

Circuit<br />

Rating<br />

CFS361JLN<br />

200kA<br />

Standard – With Right Hand Mounted Mechanism<br />

30 a<br />

30 a<br />

30 a CFS361C5<br />

CFS361J5<br />

CFS361JN<br />

Class CC<br />

Class J<br />

Class J<br />

7.5<br />

7.5<br />

7.5<br />

15<br />

15<br />

15<br />

20<br />

20<br />

20<br />

5 c<br />

5 c<br />

5 c 100kA<br />

100kA<br />

200kA<br />

60 a CFS362JN1 Class J 15 30 50 10 c 100kA<br />

60 a<br />

100 a<br />

200 b<br />

400 b<br />

600 b CFS362JN<br />

CFS363JN<br />

CFS364JN d<br />

CFS365JN d<br />

CFS366J hi<br />

Class J<br />

15<br />

30<br />

60<br />

125<br />

200<br />

30<br />

60<br />

125<br />

250<br />

400<br />

50<br />

75<br />

150<br />

350<br />

500<br />

10 c<br />

20 c<br />

—<br />

—<br />

—<br />

200kA<br />

800 b CFS367L hi Class L 200 400 500 — 200kA<br />

Optional – With Left Hand Mounted Mechanism d<br />

30 b<br />

Class J 7.5 15 20 5 c<br />

100 b CFS363JLN<br />

30 60 75 20 c 60 b CFS362JLN<br />

15 30 50 10 c<br />

CFS361J5<br />

5<br />

DISCONNECT<br />

SWITCHES<br />

Operating Shafts for 30-400A Switches e<br />

Catalog<br />

number<br />

Shaft length<br />

in. (mm)<br />

Switch & handle compatibility<br />

CFSS5200N 7.9 (200) 5mm x 5mm for use with CFS361C5 & CFS361J5 switches &<br />

CFSS5400N 15.7 (400) with "CFSH5" handles only<br />

CFSS5200HN 7.9 (200) 5mm x 5mm for use with all "CFSH10" handles & with<br />

CFSS5400HN 15.7 (400) CFS361C5 & CFS361J5 switches only<br />

CFSS10200HN 7.9 (200) 10mm x 10mm for use with all "CFSH10" handles & with all<br />

CFSS10400HN 15.7 (400) 30-400A switches except CFS361C5 & CFS361J5<br />

Compact rotary operating handles — door mounted<br />

(for use with CFS361C5 & CFS361J5 switches only) f<br />

Catalog<br />

number Color UL Type Operating shaft compatibility<br />

CFSH5B12N<br />

CFSH5R12N<br />

CFSH5B4N<br />

CFSH5R4N<br />

Blue & Black<br />

Yellow & Red<br />

Blue & Black<br />

Yellow & Red<br />

1, 3R & 12<br />

1, 3R, 12 & 4/4X<br />

CFSS5200N or CFSS5400N<br />

CFSS5400N<br />

Rotary Operating Handles - Door Mounted<br />

(for use with CFSS5200HN, CFSS5400HN, CFSS10200HN & CFSS10400HN)<br />

Catalog<br />

number Color Description<br />

Type 1, 3R & 12 g<br />

CFSH10B12N Blue & Black Heavy duty pistol grip (2.75” long for use<br />

CFSH10R12N Yellow & Red<br />

with 30A switches & CFS362JN1)<br />

CFSH10BL12N Blue & Black Heavy duty pistol grip<br />

CFSH10RL12N Yellow & Red<br />

(4.92” long for 30-400A switches)<br />

Type 1, 3R, 4/4X & 12 g<br />

CFSH10B4N Blue & Black Heavy duty pistol grip (2.75” long for use<br />

CFSH10R4N Yellow & Red<br />

with 30A switches & CFS362JN1)<br />

CFSH10BL4N Blue & Black Heavy duty pistol grip<br />

CFSH10RL4N Yellow & Red<br />

(4.92” long for 30-400A switches)<br />

CFSH5B12N<br />

a Line and load lugs included.<br />

b Line and load lugs are not included.<br />

Order from table on next page if required.<br />

c DC HP rating shown requires (3) poles to be connected<br />

in series.<br />

d CFS364JN & CFS365JN can be rotated 180º for left<br />

hand operation as standard.<br />

e Catalog numbers CFS361C5 & CFS361J5 accept 5mm<br />

x 5mm operating shafts. All other 30-400A switches<br />

accept 10mm x 10mm operating shafts.<br />

f Compact pistol grip design (2.75” long) with defeatable<br />

cover interlock. Cover can be opened when handle is<br />

padlocked in the OFF position.<br />

g Defeatable cover interlock provided. Cover cannot be<br />

opened when handle is padlocked in the OFF position.<br />

h 4 pole 600 & 800A switches, CFS466J & CFS467L are<br />

also available.<br />

i CFS366J and CFS367L are rated 250 & 600V DC when<br />

(2) poles are connected in series.<br />

5-16<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category HDSS


Disconnect Switches<br />

Type CFS Compact Fusible Switches<br />

Revised on 01/31/20<br />

Selection and Accessories<br />

600 & 800A Rotary Operating Handles - Door Mounted (8.27” long) g<br />

Catalog<br />

number Color UL Type<br />

CFSH12BL12 Blue & Black 1, 3R & 12<br />

CFSH12RL12 Yellow & Red 1, 3R & 12<br />

CFSH12BL4 Blue & Black 1, 3R, 12 & 4/4X<br />

CFSH12RL4 Yellow & Red 1, 3R, 12 & 4/4X<br />

600 & 800A Operating Shafts (Cross Section 12mm x 12mm)<br />

Catalog<br />

number<br />

Shaft length<br />

in. (mm)<br />

CFSS12200H 12.59 (320) 10.43 – 16.68 in.<br />

CFSS12400H 15.75 (400) 10.43 – 19.84 in.<br />

Enclosure depth<br />

(switch mounting surface to door OD)<br />

CFSL200 & 400<br />

Type CFS Fusible Switch Accessories<br />

Catalog<br />

number<br />

Description<br />

Terminals a<br />

CFSL200 200A lug kit (6 lugs per kit) #6-3/0<br />

CFSL400N<br />

400A lug kit (6 lugs per kit) #2-600kcmil (for CFS365JN only)<br />

CNFSL400D 400A lug kit (6 lugs per kit, 2 wires per lug) #6-350kcmil<br />

CFSL400<br />

600-800A lug kit (6 lugs per kit, 2 wires per lug) #2-600kcmil i<br />

Shorting bars (no fuse kits)<br />

CFSSB60<br />

60A shorting bar kit (3 links per kit)<br />

CFSSB100<br />

100A shorting bar kit (3 links per kit)<br />

CFSSB200<br />

200A shorting bar kit (3 links per kit)<br />

CFSSB400<br />

400A shorting bar kit (3 links per kit)<br />

CFSSB680<br />

600 & 800A shorting bar kit (1 link per kit)<br />

Auxiliary contacts (NEMA ratings AC A600 DC N600)<br />

CFSAUXH1 b Aux contact holder (CFS361C5 & CFS361J5)<br />

CFSAUX1NO Aux contact 1 NO (30-800A Sws)<br />

CFSAUX1NC Aux contact 1 NC (30-800A Sws)<br />

CFS11AUX 1NO, 1NC aux contact kit (side mount for 200kA switches)<br />

CFS22AUX 2NO, 2NC aux contact kit (side mount for 200kA switches)<br />

Terminal shrouds (line or load)<br />

CFSTS200N h 200A shroud kit (line or load 3-pole kit)<br />

CFSTS400N h 400A shroud kit (line or load 3-pole kit for CFS365JN only)<br />

CFSTS680 f 600/800A 3-pole shroud kit<br />

CFSTS6804 f 600/800A 4-pole shroud kit<br />

30A compact switch kits<br />

CFSPLK<br />

Shaft padlocking kit for 30A compact switch when door is opend<br />

CFSH5CDM Direct mount handle kit for CFS361C5<br />

CFSH5JDM Direct mount handle kit for CFS361J5<br />

CFSAUX1NC<br />

CFSSB100 – CFSSB400<br />

5 DISCONNECT<br />

SWITCHES<br />

NFPA 79 kits (if auxiliary contacts are needed, see table above)<br />

Kits provide an operating shaft suitable for use with all heavy duty handles (not for use with CFSH5 handles).<br />

Kits also provide an internal operating handle and an internal OFF padlocking provision.<br />

CFSNFPA1 d For use with CFS361C5 & CFS361J5<br />

CFSNFPA2N e For use with CFS361JN, CFS361CN, CFS362JN1, CFS362JN, CFS363JN & CFS364JN<br />

CFSNFPA3N e For use with CFS365JN only<br />

a Supplied as standard on 30-100A switches<br />

b CFS361C5 will accept (4) aux contacts without an aux<br />

contact holder. CFS361J5 will accept (2) aux contacts<br />

without an aux contact holder.<br />

c Supplied as standard on all but 30A, 100kA<br />

compact switches.<br />

d 12.6 in. (320 mm) long operating shaft included<br />

e 12.7 in. (323 mm) long operating shaft included<br />

f Line side terminal shrouds supplied with switch<br />

g Defeatable cover interlock included.<br />

Cover cannot be opened when the handle is<br />

padlocked in the OFF position.<br />

h Neither line or load terminal shrouds are supplied as<br />

standard with new style 200 & 400A switches.<br />

i 2 kits needed for 800A, total 12 lugs to cover line and<br />

load sides<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 5-17


Disconnect Switches<br />

Type CFS Compact Fusible Switches<br />

Revised on 01/31/20<br />

Technical Characteristics<br />

UL & CSA Technical Characteristics And Panel Space Requirements<br />

Fuse Ac Short Electrical Mechanical<br />

Panel Space Requirements - in. (mm)<br />

Catalog Number Amps Class Circuit Rating Endurance Endurance Height Width Depth a<br />

CFS361C5 30 CC 100kA 6000 10000 4.56 (116) 3.78 (96) 6.00 (152)<br />

CFS361J5 30 J 100kA 6000 10000 4.56 (116) 4.15 (105) 6.00 (152)<br />

CFS361JN 30 J 200kA 6000 10000 5.35 (136) 5.89 (150) 6.00 (152)<br />

CFS361JLN 30 J 200kA 6000 10000 5.35 (136) 5.89 (150) 6.00 (152)<br />

CFS362JN1 60 J 100kA 6000 10000 5.35 (136) 5.89 (150) 6.00 (152)<br />

CFS362JN 60 J 200kA 6000 10000 7.32 (186) 5.89 (150) 6.00 (152)<br />

CFS362JLN 60 J 200kA 6000 10000 7.32 (186) 5.89 (150) 6.00 (152)<br />

CFS363JN 100 J 200kA 6000 10000 7.32 (186) 5.89 (150) 6.00 (152)<br />

CFS363JLN 100 J 200kA 6000 10000 7.32 (186) 5.89 (150) 6.00 (152)<br />

CFS364JN 200 J 200kA 6000 8000 11.46 (291) 7.72 (196) 6.00 (152)<br />

CFS365JN 400 J 200kA 1000 6000 15.35 (390) 10.19 (259) 8.00 (203)<br />

CFS366J 600 J 200kA 1000 5000 11.81 (300) 14.33 (364) 11.00 (280)<br />

CFS466J 600 J 200kA 1000 5000 11.81 (300) 18.03 (458) 11.00 (280)<br />

CFS367L 800 L 200kA 500 3500 11.81 (300) 14.33 (364) 11.00 (280)<br />

CFS467L 800 L 200kA 500 3500 11.81 (300) 18.03 (458) 11.00 (280)<br />

5<br />

DISCONNECT<br />

SWITCHES<br />

Wire Ranges Line & Load Lugs<br />

Switch<br />

Amperage Rating<br />

UL Approved<br />

Wire Size (75º C)<br />

CFS361J5 30 (1)#14-10<br />

CFS361C5 30 (1)#14-10<br />

CFS361JN 30 (1)#14-6<br />

CFS362JN1 60 (1)#14-6<br />

CFS362JN 60 (1)#12-1<br />

CFS363JN 100 (1)#12-1<br />

CFS364JN 200 (1)#3/0<br />

CFS365JN 400 (1)600MCM<br />

CFS366J 600 (2)350 MCM<br />

CFS367L 800 (2)600 MCM<br />

Auxiliary Contact Capability When An NFPA79 Kit Is Used<br />

Switch NFPA79 Kit Aux Contacts That Can Be Installed<br />

CFS361C5<br />

(2) Total, CFSAUX1NO or CFSAUX1NC<br />

CFSNFPA1<br />

CFS361J5<br />

(1) CFSAUX1NO or (1) CFSAUX1NC<br />

CFS361JN<br />

CFS362JN1<br />

CFS362JN<br />

CFS363JN<br />

CFS364JN<br />

CFS365JN<br />

CFSNFPA2N<br />

CFSNFPA3N<br />

(2) Total, CFSAUX1NO or CFSAUX1NC b<br />

(2) Total, CFSAUX1NO or CFSAUX1NC b<br />

a Minimum dimensions from mounting surface to inside<br />

of cover. Dimensions shown can be decreased if aux<br />

contacts are not required.<br />

b For additional auxiliary contacts use side mounted<br />

CFS11AUX or CFS22AUX.<br />

5-18<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Disconnect Switches<br />

Type CNFS Switches, Shafts And Handles<br />

Revised on 01/31/20<br />

General Information<br />

Type CNFS Compact Non-Fusible Switches<br />

Description<br />

Siemens Type CNFS compact non-fusible switches meet UL<br />

98 requirements and can be used in either service entrance<br />

or branch circuit applications. They are available in 30-800A,<br />

3-pole switches and are all rated 600VAC maximum.<br />

All are open style, designed to be panel mounted and are UL<br />

listed under file number #E121152 or #E68312 and CSA certified<br />

under file number #222227. A variety of door mounted<br />

rotary operators are available with Type 1, 3R, 12 or 4/4X<br />

ratings.<br />

These non-fusible switches are UL listed under file<br />

#E201138 and CSA certified under file #112964. They also<br />

conform to IEC standard 60947-3.<br />

Catalog Numbering System<br />

CNFS Switches<br />

Compact Non-Fusible Switch<br />

• Number of poles 3 = 3<br />

• Max. Voltage Rating 6 = 600V<br />

• Ampere rating<br />

1 = 30A<br />

2 = 60A<br />

3 = 100A<br />

4 = 200A<br />

5 = 400A<br />

6 = 600A<br />

7 = 800A<br />

• Design type<br />

N = Compact design<br />

CNFS 3 6 1 N<br />

5 DISCONNECT<br />

SWITCHES<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 5-19


Disconnect Switches<br />

Type CNFS Compact Non-Fusible Switches<br />

Revised on 01/31/20<br />

Features And Ordering Information<br />

Features<br />

• 30 - 800A ratings<br />

• UL Listed under file #E201138 & CSA Certified under file<br />

#112964 or #703166<br />

• Options to have door mounted pistol handles with defeatable<br />

cover interlock or direct mounted handles.<br />

• Meets UL 98 requirements<br />

• Compact size<br />

• All short circuit protection ratings require the use of Class J<br />

fuses in the circuit.<br />

• Load break and horsepower rated<br />

• Quick make and break operation<br />

• All external handles and direct handles for 600-800A switches<br />

are padlockable with up to (3) padlocks with 5/16” hasps<br />

in the OFF postition. Direct handles for 30-100A switches<br />

are padlockable with (1) padlock with 3/16” hasps in the<br />

OFF position.<br />

• All switches are able to be panel mounted. Catalog numbers<br />

CNFS361N, CNFS362N, & CNFS363N can also be DIN-rail<br />

mounted and can either be front or side operated with standard<br />

pistol handles.<br />

• Handles are available in Type 1, 3R, 4/4X & 12 ratings<br />

Shaft Handle Lugs/Accessories<br />

DISCONNECT<br />

SWITCHES<br />

5<br />

CFSS10200HN CFSH10BL12N CFSL200<br />

Ordering information<br />

1. Select the panel mounted switch required based on<br />

Ampere, HP and AIC requirements. Switches with a right<br />

hand mechanism are standard.<br />

2. Select handle based on environmental rating required.<br />

3. For door mounted handles, select operating shaft based<br />

on enclosure depth. For enclosure depths of 9.00” or less<br />

from panel mounting surface to inside of door use up to<br />

200 mm long shafts. From 9.00” to 13.00” use up to 320<br />

mm long shafts. For deeper enclosures use up to 400 mm<br />

long shafts. For direct mount handles, no shaft is needed.<br />

Note: Be sure to check shaft and handle compatibility with<br />

the switch selected by using information provided in the<br />

selection tables.<br />

4. Line & load lugs are provided as standard on 30-100A<br />

switches. Terminal kits are available for 200-800A<br />

switches if needed.<br />

5. Auxiliary contacts are available if needed. Each switch<br />

will accept up to (2) aux contact modules, containing<br />

(2) contacts in each.<br />

6. 30-100A Series N switches are designed to prevent<br />

inadvertent contact with live parts and shields are not<br />

required but are offered as terminal shrouds. 100-400A<br />

switches are not supplied with terminal shields. They<br />

are available as separate field installed kits for both line<br />

and load terminals by amperage rating. Line side terminal<br />

screens are provided for 600-800A switches.<br />

5-20<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Disconnect Switches<br />

Type CNFS Compact Non-Fusible Switches<br />

Revised on 01/31/20<br />

Shaft and Handle Selection<br />

Type CNFS compact non-fusible switches<br />

Max Horsepower Ratings<br />

Switch<br />

Ampere Catalog<br />

240V 480V 600V<br />

Short Circuit Rating<br />

Rating Number<br />

3Ø AC 3Ø AC 3Ø AC @ 480VAC @ 600VAC<br />

30 CNFS361N a 10 20 25 100 100<br />

60 CNFS362N a 20 40 50 100 100<br />

100 CNFS363N a 20 50 50 100 25<br />

200 CNFS364N b 75 150 200 200 200<br />

400 CNFS365N b 125 250 350 200 200<br />

600 CNFS366N b 200 400 350 200 200<br />

800 CNFS367N b 200 500 500 100 100<br />

CNFS363N<br />

Direct mount rotary handles for compact non-fusible switches<br />

Catalog Number Color Use with compact non-fusible switches<br />

CNFSHD1 Blue CNFS361N, CNFS362N, CNFS363N<br />

CNFSHD2 Black CNFS364N, CNFS365N<br />

CNFSHD3 Black CNFS366N, CNFS367N<br />

Operating shafts for compact non-fusible switches<br />

Catalog Number Shaft length in. (mm) Switch and handle compatibility<br />

CNFSS52001 7.9 (200)<br />

5mm x 5mm for use with<br />

CNFSS53201 12.6 (320)<br />

CNFS361N, CNFS362N and CNFS363N switches<br />

CNFSS54001 15.7 (400)<br />

and with "CNFSH5" handles only<br />

CFSS10200HN 7.9 (200)<br />

CNFSS103202 12.6 (320)<br />

CFSS10400HN 15.7 (400)<br />

CNFSS152003 7.9 (200)<br />

CNFSS153203 12.6 (320)<br />

CNFSS154003 15.7 (400)<br />

10mm x 10mm for use with<br />

"CFSH10" handles and with CNFS364N<br />

and CNFS365N switches only<br />

15mm x 15mm for use with<br />

"CFSH12" handles and with CNFS366N<br />

and CNFS367N switches only<br />

CNFSS154003<br />

5 DISCONNECT<br />

SWITCHES<br />

Compact rotary operating handles for non-fusible switches – door mounted<br />

Catalog Number Color UL Type<br />

Operating shaft<br />

compatibility<br />

Use with<br />

non-fusible<br />

compact switches<br />

CNFSH5BP121 Black NEMA 1, 3R, 12<br />

CNFSH5RP121 Red/Yellow NEMA 1, 3R, 12<br />

CNFSH5BP41 Black NEMA 4/4X<br />

CNFSS52001,<br />

CNFSS53201,<br />

CNFSS54001<br />

CNFS361N,<br />

CNFS362N,<br />

CNFS363N<br />

CFSH12RL12<br />

CNFSH5RP41 Red/Yellow NEMA 4/4X<br />

CFSH10BL12N Black NEMA 1, 3R, 12<br />

CFSH10RL12N Red/Yellow NEMA 1, 3R, 12<br />

CFSH10BL4N Black NEMA 4/4X<br />

CFSH10RL4N Red/Yellow NEMA 4/4X<br />

CFSS10200HN,<br />

CNFSS103202,<br />

CFSS10400HN<br />

CNFS364N,<br />

CNFS365N<br />

CFSH12BL12 Black NEMA 1, 3R, 12<br />

CFSH12RL12 Red/Yellow NEMA 1, 3R, 12<br />

CFSH12BL4 Black NEMA 4/4X<br />

CFSH12RL4 Red/Yellow NEMA 4/4X<br />

CNFSS152003,<br />

CNFSS153203,<br />

CNFSS154003<br />

CNFS366N,<br />

CNFS367N<br />

a Line and load lugs are included.<br />

b Line and load lugs are not included. Order from table<br />

on following pages if needed.<br />

c All switches can be rotated 180° for left hand operation<br />

as standard.<br />

d Compact pistol grip design (2.75” long) with defeatable<br />

cover interlock. Cover can be opened when handle is<br />

padlocked in the OFF position.<br />

e Defeatable cover interlock provided. Cover cannot be<br />

opened when handle is in the OFF position.<br />

f Flange mounting is not available for non-fusible<br />

switches.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 5-21


5<br />

DISCONNECT<br />

SWITCHES<br />

Revised on 01/31/20<br />

Disconnect Switches<br />

Type CNFS Compact Non-Fusible Switches<br />

Additional Accessories<br />

Auxiliary contacts for use with non-fusible switches<br />

Use with Non-fusible<br />

Catalog Number Number of Contacts<br />

Contact Switches<br />

CNFS1AUX1 1 Normally Open + 1 Normally Closed<br />

CNFS361N, CNFS362N, CNFS363N<br />

CNFS2AUX1 2 Normally Closed<br />

CNFS1AUX2<br />

1st Auxiliary Contact:<br />

1 Normally Open + 1 Normally Closed CNFS364N, CNFS365N, CNFS366N,<br />

CNFS2AUX2<br />

2nd Auxiliary Contact:<br />

CNFS367N<br />

1 Normally Open + 1 Normally Closed<br />

Terminal shrouds for use with non-fusible switches<br />

Use with Non-fusible<br />

Catalog Number Shroud Location<br />

Contact Switches<br />

CNFS1AUX1<br />

CNFSTS100 Top and Bottom CNFS361N, CNFS362N, CNFS363N<br />

CNFSTSC200T Top<br />

CNFS364N<br />

CNFSTSC200B Bottom<br />

CNFSTSC400T Top<br />

CNFS365N<br />

CNFSTSC400B Bottom<br />

CNFSTSC600B Bottom CNFS366N<br />

CNFSTSC800B Bottom CNFS367N<br />

Terminal lug kits for use with non-fusible switches<br />

Use with Non-fusible<br />

Catalog Number Wire Sizes<br />

Contact Switches<br />

Included #10-2/0 CNFS361N, CNFS362N, CNFS363N<br />

CNFSTSC400T<br />

CFSL200 #6-300MCM CNFS364N<br />

CFSL400N #2-600MCM CNFS365N<br />

CNFSL400D #6-350MCM, 2 wires per lug CNFS356N<br />

CFSL200 & 400<br />

a 2 kits needed for 800A, total 12 lugs to cover line and<br />

load sides.<br />

5-22<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Disconnect Switches<br />

Type VB Panelboard Units<br />

Revised on 07/31/18<br />

Selection<br />

Fusible Units For SB1, SB2 Switchboards and F1, F2 Panelboards<br />

Catalog Numbering System V 7 E 3 2 3 3 A<br />

Vacu-Break<br />

Unit<br />

Width<br />

2 = 12" 7 = 17" M = 17" (Main)<br />

Height<br />

A = 2 1 ⁄2" B = 5" E = 7 1 ⁄2" F = 10" H = 15" S = 18.75"<br />

Number of Poles<br />

2 3<br />

Voltage Rating<br />

2 = 240V 6 = 600V<br />

Amperes<br />

0 = Single Unit<br />

Double 1 = 30A 2 = 60A 3 = 100A 4 = 200A<br />

Ampere Rating<br />

1 = 30A 2 = 60A 3 = 100A 4 = 200A 5 = 400A 6 = 600A<br />

Series Type<br />

A = 400A, 600A Omit = 30A–200A, 800A–1200A<br />

Example: V7E3233 = Vacu-Break Unit, 17" Wide, 7 1 ⁄2" High, 3-Pole, 240 Volts, Double Branch Unit with 100 Amp<br />

Rating each side. Suffix letters MS indicate Main Switch.<br />

Vacu-Break ® Fusible Units<br />

2-Pole a , 12" Wide<br />

240V AC, 250V DC<br />

Ampere<br />

Unit<br />

Height<br />

Unit<br />

Depth<br />

Horsepower Rating<br />

240 Volt AC<br />

250 Volt<br />

Unit<br />

Lug Wire Range (Cu/AI) Weight Catalog<br />

Rating (inches) (inches) Standard Maximum DC and Cables Per Pole (pounds) Number<br />

130–30 2 1 ⁄2 b 4 1 ⁄2 01 1 ⁄2 03 05 (1)–#14 to #8 (Cu Only) 15 V2A2211LRn<br />

130–30 5 4 1 ⁄2 01 1 ⁄2 03 05 (1)–#14 to #4 19 V2B2211LRn<br />

130–60 5 4 1 ⁄2 01 1 ⁄2–3 03–10 05–10 (1)–#14 to #2 19 V2B2212LRn<br />

160–60 5 4 1 ⁄2 03 10 10 (1)–#14 to #2 19 V2B2222LRn<br />

100 7 1 ⁄2 6 3 ⁄4 07 1 ⁄2 15 20 (1)–#14 to #1/0 14 V2E2203LRn<br />

200 7 1 ⁄2 6 3 ⁄4 15 — 40 (1)–#6 to 350 kcmil 19 V2E2204LRn<br />

3-Pole<br />

240V AC, 250V DC<br />

Ampere<br />

Unit<br />

Height<br />

Unit<br />

Depth<br />

Horsepower Rating<br />

240 Volt AC<br />

Unit<br />

Lug Wire Range (Cu/AI) Weight Catalog<br />

Rating (inches) (inches) Standard Maximum and Cables Per Pole (pounds) Number<br />

Branch Circuits, 12" Wide Units<br />

130–30 2 1 ⁄2 b 4 1 ⁄2 03 07 1 ⁄2 (1)–#14 to #8 (Cu Only) 5 V2A3211n<br />

130–30 5111 4 1 ⁄2 03 07 1 ⁄2 (1)–#14 to #4 9 V2B3211n<br />

130–30 5111 4 1 ⁄2 03 07 1 ⁄2 (1)–#14 to #4 9 V2B3211R c n<br />

130–60 5111 4 1 ⁄2 03–7 1 ⁄2 07 1 ⁄2–15 (1)–#14 to #2 9 V2B3212n<br />

130–60 5111 4 1 ⁄2 03–7 1 ⁄2 07 1 ⁄2–15 (1)–#14 to #2 9 V2B3212R c n<br />

160–60 5111 4 1 ⁄2 07 1 ⁄2 15 (1)–#14 to #2 9 V2B3222<br />

160–60 5111 4 1 ⁄2 07 1 ⁄2 15 (1)–#14 to #2 9 V2B3222R c n<br />

100 7 1 ⁄2 6 3 ⁄4 15 30 (1)–#14 to #1/0 14 V2E3203<br />

200 10 11 6 3 ⁄4 25 60 (1)–#6 to 350 kcmil 21 V2F3204<br />

Main Switch d , 12" Wide Units, Back Connected<br />

200 10 6 3 ⁄4 25 50 e 21 V2F3204MSn<br />

5 DISCONNECT<br />

SWITCHES<br />

For inches / millimeters conversion, multiply inches by 25.4.<br />

n Built to order. Allow 4–6 weeks for delivery.<br />

a These units are available in LR (left, right) connection<br />

figurations only.<br />

b This unit is not a Vacu-Break unit, but rather operates on<br />

a sliding contact, double break principle. Rated 10,000 AIC<br />

max. with either Class H or K fuses. Will not accept Class R<br />

fuse clip kits.<br />

c Units set up for R-fuse application only.<br />

d For 2-pole main switch (200A), use 3-pole main switch<br />

Vacu-Break unit.<br />

e Load-side furnished with spade type bolted terminal pads.<br />

Product Category VBSS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 5-23


Disconnect Switches<br />

Type VB Panel Units<br />

Revised on 07/31/18<br />

Selection<br />

Vacu-Break ® Fusible Units for SB1, SB2 Switchboards and F1, F2 Panelboards<br />

Ampere<br />

Unit<br />

Height<br />

Unit<br />

Depth<br />

Horsepower Rating<br />

240 Volt AC<br />

250 Volt Lug Wire Range (Cu/AI)<br />

Unit<br />

Weight Catalog<br />

Rating (inches) (inches) Standard Maximum DC and Cables Per Pole (pounds) Number<br />

2-Pole a , Branch Circuits, 17" Wide Units<br />

240V AC, 250V DC<br />

30–30 12 1 ⁄2 b 6 3 ⁄4 01 1 ⁄2 003 05 (1)–#14 to #8 (Cu Only) 15 V7A2211__ ac n<br />

30–30 15 6 3 ⁄4 01 1 ⁄2 003 05 (1)–#14 to #4 19 V7B2211LRm<br />

30–30 15 6 3 ⁄4 01 1 ⁄2 003 05 (1)–#14 to #4 19 V7B2211_ a _R e<br />

30–60 c 15 6 3 ⁄4 01 1 ⁄2 –3 003–10 05–10 (1)–#14 to #2 19 V7B2212LR d n<br />

30–60 c 15 6 3 ⁄4 01 1 ⁄2 –3 003–10 05–10 (1)–#14 to #4 19 V7B2212LRR e n<br />

60–60 15 6 3 ⁄4 03 010 10 (1)–#14 to #2 19 V7B2222__ ac<br />

60–60 15 6 3 ⁄4 03 010 10 (1)–#14 to #2 19 V7B2222_ a _R e<br />

60–100 c 17 1 ⁄2 6 3 ⁄4 03–7 1 ⁄2 010–15 10–20 (1)–#14 to #1/0 18 V7E2223LR d n<br />

100–100 17 1 ⁄2 6 3 ⁄4 07 1 ⁄2 015 20 (1)–#14 to #1/0 20 V7E2233__ a m<br />

200 17 1 ⁄2 6 3 ⁄4 15 — 40 (1)–#6 to 350 kcmil 21 V7E2204__ a r<br />

400 10 10.5<br />

— —<br />

(1)-#1/0 to 750 kcmil or<br />

50<br />

(2)-#1/0 to 300 kcmil<br />

35 V7F3205A ●<br />

400 15 10.5<br />

— —<br />

(2)-#1/0 to 750 kcmil or<br />

50<br />

(4)-#1/0 to #4/0<br />

44 V7H2205A ●<br />

600 15 10.5<br />

— — — (2)-#1/0 to 750 kcmil or<br />

(4)-#1/0 to #4/0<br />

44 V7H2206A n●<br />

5<br />

DISCONNECT<br />

SWITCHES<br />

3-Pole, Branch Circuits, 17" Wide Units<br />

30–30 12 1 ⁄2 b 6 3 ⁄4 03 007 1 ⁄2 — (1)–#14 to #8 (Cu Only) 15 V7A3211<br />

30–30 15 6 3 ⁄4 03 007 1 ⁄2 — (1)–#14 to #4 19 V7B3211<br />

30–30 15 6 3 ⁄4 03 007 1 ⁄2 — (1)–#14 to #4 19 V7B3211R e<br />

30–60 15 6 3 ⁄4 03–7 1 ⁄2 007 1 ⁄2–15 — (1)–#14 to #2 19 V7B3212<br />

30–60 15 6 3 ⁄4 03–7 1 ⁄2 007 1 ⁄2–15 — (1)–#14 to #2 19 V7B3212R e<br />

60–60 15 6 3 ⁄4 07 1 ⁄2 015 — (1)–#14 to #2 19 V7B3222<br />

60–60 15 6 3 ⁄4 07 1 ⁄2 015 — (1)–#14 to #2 19 V7B3222R e<br />

60 17 1 ⁄2 6 3 ⁄4 07 1 ⁄2 015 — (1)–#14 to #1/0 13 V7E3202<br />

60–100 17 1 ⁄2 6 3 ⁄4 07 1 ⁄2–15 015–30 — (1)–#14 to #1/0 18 V7E3223<br />

100–100 17 1 ⁄2 6 3 ⁄4 15 030 — (1)–#14 to #1/0 20 V7E3233<br />

100–100 17 1 ⁄2 6 3 ⁄4 15 030 — (1)–#14 to #1/0 20 V7E3233R e<br />

100 17 1 ⁄2 6 3 ⁄4 15 030 — (1)–#14 to #1/0 14 V7E3203<br />

200–200 10 6 3 ⁄4 25 060 — (1)–#6 to 300 kcmil 40 V7F3644 f<br />

200–200 10 6 3 ⁄4 25 060 — (1)–#6 to 300 kcmil 40 V7F3244R e<br />

200 10 6 3 ⁄4 25 060 — (1)–#6 to 350 kcmil 21 V7F3204<br />

400 10 10.5 100 250 125<br />

(1)-#1/0 to 750 kcmil or<br />

(2)-#1/0 to 300 kcmil<br />

35 V7F3205A g ●<br />

400 15 10.5 100 250 125<br />

(2)-#1/0 to 750 kcmil or<br />

(4)-#1/0 to #4/0<br />

44 V7H3205A●<br />

600 15 10.5 150 400 200<br />

(2)-#1/0 to 750 kcmil or<br />

(4)-#1/0 to #4/0<br />

44 V7H3206A●<br />

240V AC<br />

3-Pole, Main Switch, 17" Wide Units (Vertical Mount, Top Feed, Front Connected)<br />

400 18.75 10 3 ⁄8 50 125 — — — VMS325T<br />

600 18.75 10 3 ⁄8 75 200 — — — VMS326T<br />

3-Pole, Main Switch, 17" Wide Units (Vertical Mount, Bottom Feed, Front Connected)<br />

400 18.75 10 3 ⁄8 50 125 — — — VMS325B<br />

600 18.75 10 3 ⁄8 75 200 — — — VMS326B<br />

240V AC<br />

240V AC<br />

For inches / millimeters conversion, multiply inches by 25.4.<br />

n Built to order. Allow 4-6 weeks for delivery.<br />

r MR suffix. Built to order. Allow 4-6 weeks for delivery.<br />

m MR, LM suffix. Built to order. Allow 4-6 weeks for<br />

delivery.<br />

● A suffix. New 'Series A' design<br />

aOrder 2-pole branch circuit units by adding appropriate<br />

connection designation LM, LR or MR (indicating Left, Middle<br />

and Right, facing the panel).<br />

b This unit is not a Vacu-Break unit, but rather operates on a sliding<br />

contact, double break principle. Rated 10,000 AIC max. with<br />

either Class H or K fuses. Will not accept Class R fuse clip kits.<br />

c MR not available.<br />

d Available as Type LR connection designation only.<br />

e Switches set up for R-fuse applications only.<br />

f Rated 600 Volts but factory configured to accept 250V Class<br />

H, K or R fuses. Field convertible for Class J fuses for 600V<br />

applications. Field convertible for 300V Class T fuse with<br />

TFAK42 kit.<br />

g Compact 10" version of 400A.<br />

V7B2222MR not available<br />

3-pole compact 10" version suitable for 2-pole application.<br />

5-24<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category VBSS


Disconnect Switches<br />

Type VB Panel Units<br />

Revised on 07/31/18<br />

Selection<br />

Vacu-Break ® Fusible Units For SB1, SB2 Switchboards and F1, F2 Panelboards<br />

Ampere<br />

Unit<br />

Height<br />

Unit<br />

Depth<br />

Horsepower Rating<br />

480 Volt AC 600 Volt AC<br />

Lug Wire Range (Cu/AI)<br />

Unit<br />

Weight Catalog<br />

Rating (inches) (inches) Standard Maximum Standard Maximum and Cables Per Pole (pounds) Number<br />

2-Pole, Branch Circuits, 17" Wide Units a<br />

600V AC, 250V DC<br />

1130–30 17 1 ⁄2 6 3 ⁄4 003 007 1 ⁄2 003 010 (1)–#14 to #4 14 V7E2611LR h n<br />

1130–60 17 1 ⁄2 6 3 ⁄4 003–5 007 1 ⁄2–20 003–5 020–25 (1)–#14 to #4 14 V7E2612LR h n<br />

1100 17 1 ⁄2 6 3 ⁄4 010 020 015 040 (1)–#14 to #1/0 14 V7E2603LR h n<br />

3-Pole, Branch Circuits, 17" Wide Units<br />

600V AC, 250V DC<br />

1130–30 17 1 ⁄2 6 3 ⁄4 005 015 007 1 ⁄2 020 (1)–#14 to #4 14 V7E3611<br />

1130–30 17 1 ⁄2 6 3 ⁄4 005 015 007 1 ⁄2 020 (1)–#14 to #4 14 V7E3611R g<br />

1130 17 1 ⁄2 6 3 ⁄4 005 015 007 1 ⁄2 020 (1)–#14 to #4 14 V7E3601<br />

1130–60 17 1 ⁄2 6 3 ⁄4 005–15 015–30 007 1 ⁄2–15 020–50 (1)–#14 to #2 14 V7E3612<br />

1160–60 17 1 ⁄2 6 3 ⁄4 015 030 015 050 (1)–#14 to #2 14 V7E3622<br />

1160–60 17 1 ⁄2 6 3 ⁄4 015 030 015 050 (1)–#14 to #2 14 V7E3622R g<br />

1160 17 1 ⁄2 6 3 ⁄4 015 030 015 030 (1)–#14 to #2 14 V7E3602<br />

1160–100 17 1 ⁄2 6 3 ⁄4 015–25 030–60 015–30 050–75 (1)–#14 to #1/0 18 V7E3623<br />

1100–100 17 1 ⁄2 6 3 ⁄4 025 060 030 075 (1)–#14 to #1/0 20 V7E3633<br />

1100–100 17 1 ⁄2 6 3 ⁄4 025 060 030 075 (1)–#14 to #1/0 20 V7E3633R g<br />

1100 17 1 ⁄2 6 3 ⁄4 025 060 030 075 (1)–#14 to #1/0 14 V7E3603<br />

1200–200 10 6 3 ⁄4 050 125 060 150 (1)–#6 to 300 kcmil 40 V7F3644J b<br />

1200 10 6 3 ⁄4 050 125 060 150 (1)–#6 to 350 kcmil 21 V7F3604<br />

1200 10 6 3 ⁄4 050 125 060 150 (1)–#6 to 350 kcmil 21 V7F3604R g<br />

1400 10 101⁄2 100 250 125 350<br />

(1)-#1/0 to 750 kcmil or<br />

(2)-#1/0 to 300 kcmil<br />

35 V7F3605A ●<br />

1400 15 101⁄2 100 250 125 350<br />

(2)-#1/0 to 750 kcmil or<br />

(4)-#1/0 to #4/0<br />

44 V7H3605A●<br />

1600 15 101⁄2 150 400 200 500<br />

(2)-#1/0 to 750 kcmil or<br />

(4)-#1/0 to #4/0<br />

44 V7H3606A●<br />

3-Pole, Main Switch, 17" Wide Units (Vertical Mount, Top Feed, Front Connected)<br />

600V AC, 250V DC<br />

1400 18.75 10 3 ⁄8 100 250 125 350 c — VMS365T<br />

1600 18.75 10 3 ⁄8 150 400 200 500 c — VMS366T<br />

5 DISCONNECT<br />

SWITCHES<br />

3-Pole, Main Switch, 17" Wide Units (Vertical Mount, Bottom Feed, Front Connected)<br />

600V AC, 250V DC<br />

1400 18.75 17 11 ⁄16 100 250 125 350 c — VMS365B<br />

1600 18.75 17 11 ⁄16 150 400 200 500 c — VMS366B<br />

3-Pole, Switchboard Units, 21" Wide Units, Front Connected e<br />

600V AC, 250V DC<br />

1800 25 12 3 ⁄4 200 500 250 500 — 160 VF357TL or BL d m<br />

1200 25 12 3 ⁄4 — — — — — 160 VF358TL or BL d<br />

3-Pole, Switchboard Units, 21" Wide, Back Connected<br />

600V AC, 250V DC<br />

1800 25 12 3 ⁄4 200 500 250 500 — 160 VB357TL or BL d n<br />

1200 25 12 3 ⁄4 — — — — — 160 VB358TL or BL d n<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

u MR suffix only is available and built to order. Allow 2–3<br />

weeks for delivery.<br />

m BL suffix. Built to order. Allow 2–3 weeks for delivery.<br />

● A suffix. New 'Series A' design<br />

aCatalog number for 2-pole branch circuit units indicate<br />

connection designation LM, LR or MR (indicating Left,<br />

Middle and Right, facing the panel).<br />

bUnit configured to accept class J fuses only. Also accepts<br />

300V Class T fuses when used with TFAK42 adapter kit.<br />

cLoad-side furnished with spade type bolted terminal pads.<br />

d Suffix “T” or “TL” indicates Top Feed.<br />

Suffix “B” or “BL” indicates Bottom Feed.<br />

eBack connected units are also available. Substitute the letter<br />

“B” (back connected) for the letter “F” (front connected)<br />

in the prefix of the catalog number. All other features<br />

are identical.<br />

f Available as Type MR designation only.<br />

g Switches set up for R-fuse applications only.<br />

h Available as Type LR designation only.<br />

3-pole compact 10" version suitable for 2-pole application.<br />

Product Category VBSS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 5-25


Disconnect Switches<br />

Type VB Panelboard Units, Accessories<br />

Revised on 07/31/18<br />

Selection<br />

Extension Kits<br />

To extend Vacu-Break unit’s depth,<br />

order the extension kit which meets<br />

the specifications of the unit to be<br />

extended. Specify by catalog number<br />

from the table to the right.<br />

Fuse Adapter Kits<br />

Unit Type<br />

Unit Height<br />

(inches)<br />

Normal<br />

Unit Depth<br />

(inches)<br />

Extended<br />

Unit Depth<br />

(inches)<br />

Catalog<br />

Number<br />

V2A 12 1 ⁄2 4 9 ⁄16 16 3 ⁄4 W43000n<br />

V2B 15 4 9 ⁄16 16 3 ⁄4 W43002<br />

V7A 12 1 ⁄2 6 3 ⁄4 10 1 ⁄2 W48762<br />

V7B 15 6 3 ⁄4 10 1 ⁄2 W48763<br />

V7E 17 1 ⁄2 6 3 ⁄4 10 1 ⁄2 W48764<br />

V7F 10 6 3 ⁄4 10 1 ⁄2 W48765 <br />

Class R and Class J Fuse Kits are single unit part numbers. Order (2) kits for dual units. Class T Fuse Kits are single pole part numbers.<br />

Order (3) kits for a 3-pole unit. To order the kit which meets the specifications of the unit to be changed, specify by catalog number<br />

from the tables below.<br />

5<br />

240 Volt Fuse Adapter Kits<br />

Switch Class R Kits Class J Kits Class T Kits<br />

Amperage Catalog Number Catalog Number Catalog Number<br />

130 b Factory Inst. — —<br />

160 W56628 — —<br />

100 W55365 W49827 TFAK32<br />

200 W55366 W49819 TFAK42<br />

400 HR65A — HT25A<br />

600 HR66A HJ66A gh HT26A<br />

600 Volt Fuse Adapter Kits<br />

Switch Class R Kits Class J Kits Class T Kits<br />

Amperage Catalog Number Catalog Number Catalog Number<br />

130 W56623 W49832 —<br />

160 W56629 W49830 —<br />

100 W55365 W49828 TFAK35<br />

200 W55366 c W49818 a TFAK45<br />

400 HR65A HJ65A fi HT65A, HT265A j<br />

600 HR66A HJ66A HT66A<br />

800 — — TFAK75<br />

DISCONNECT<br />

SWITCHES<br />

Vacu-Break Connecting Strap Kits For Panelboards and Switchboards<br />

Ampere<br />

Rating<br />

240V Unit<br />

Height (inches)<br />

600V Unit<br />

Height (inches)<br />

P4/S4/F1, FPP (10" Deep)<br />

Strap Kit<br />

P5/S5/F2 (12.75" Deep)<br />

Strap Kit<br />

130–30 12.5 — F602 F602D —<br />

130–30 15 17.5 F657 F657D VB657<br />

130-60 15 17.5 F657 F657D VB657<br />

160–60 15 17.5 F657 F657D VB657<br />

160-100 17.5 17.5 F657 F657D VB657<br />

100-100 17.5 17.5 F657 F657D VB657<br />

100 17.5 17.5 F657 F657D VB657<br />

200 17.5, 10 17.5, 10 F671 F671D VB671<br />

200–200 10 10 F672 F672D VB610<br />

SB1, SB2, SB3, VB-5, VB-6,<br />

Strap Kit<br />

Ordering Information<br />

Catalog<br />

Number<br />

Fuse Clip Kits<br />

VBFCL3 <br />

VBFCL4 <br />

Lug Kits<br />

VBRL4<br />

V7HBB65A <br />

V7FBB65A <br />

V7HBB66A <br />

Handle Kits<br />

VBRHK1232<br />

VBRHK41<br />

VBRHK42<br />

Description<br />

100A for V2E & V7E units (6) fuse clips per kit<br />

200A for V2E, V2F, V7E & V7F units (6) fuse clips per kit<br />

200A for V2F, V7E & V7F units (3) lugs per kit<br />

Replacement lug base for 400A standard height (15") Series A<br />

Replacement lug base for 400A compact height (10") Series A<br />

Replacement lug base for 600A Series A<br />

100A for twin V2E & V7E units (2) handles per kit<br />

200A for single V2E, V2F, V7E & V7F units (1) handle per kit<br />

200A for twin V7F units (2) handles per kit<br />

VBFCL4<br />

VBRL4<br />

For inches / millimeters conversion, multiply<br />

inches by 25.4.<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

● A suffix. New 'Series A' design<br />

aFor 200 A single units only. Dual units are suitable for<br />

Class J only, when used above 240V.<br />

b5˝ unit height switches only.<br />

cFor single units only.<br />

Fuse clips provided can be used on both the line<br />

and load sides.<br />

Three line and three load fuse clips are provided.<br />

f Kit not required for branch circuit switch,<br />

relocate lug base to achieve fuse fit<br />

g J fuse option not available for 240V main switch<br />

h Lug base relocation plus kit required for branch<br />

circuit switches<br />

i Kit required for main switch only<br />

j HT265A required for V7F3605A<br />

k One lug base required per switch<br />

Not for use on V7F3605A<br />

Not for use on V7F3605A or V7F3205A<br />

VBRHK41<br />

5-26<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category VBSS


Disconnect Switches<br />

Type HCP Switchboard Units, Accessories<br />

Revised on 06/30/18<br />

Selection<br />

Features<br />

b UL Listed under file number E6849<br />

Vol 1, Sect. 8<br />

b 400-1200A ratings<br />

b Visible contacts<br />

b Field installable shunt trip and auxiliary<br />

switch accessory kits<br />

b Installs in existing Siemens<br />

switchboards and power panelboards<br />

b Suitable for use on systems with up to<br />

200,000A available fault current,<br />

RMS symmetrical when equipped with<br />

Class J or Class L fuses<br />

3-Pole, Horizontal Mount a<br />

b Group mounts with other 30A through<br />

600A switches, and 100 through 1200<br />

amp frame breakers<br />

b Allows 800A and 1200A switches in<br />

standard 38" wide distribution sections<br />

in either main or branch configurations<br />

b 16 1 ⁄4" mounting height is the smallest<br />

1200A design in the industry, allowing<br />

up to 4 units in one vertical section<br />

b Field reversible horizontal mounting<br />

design for left or right hand cabling<br />

b Handle can be padlocked in the OFF<br />

position with up to three padlocks with<br />

5/16" hasps. A cover padlocking<br />

provision is also supplied<br />

Horsepower Rating<br />

Maximum Maximum<br />

Catalog Ampere AC Voltage Fuse<br />

Dimensions (inches*) 240V 480V 600V<br />

250V<br />

Number Rating Rating b Class H W D Std Max Std Max Std Max DC<br />

HCP367HJ400 1400 600 J 16.25 17.22 7.38 150 125 100 250 125 350 40<br />

HCP367HJ600 1600 600 J 16.25 17.22 7.38 175 200 150 400 200 400 40<br />

HCP327HT 800 240 T 16.25 17.22 7.38 100 250 — — — — 50<br />

HCP367H 1800 600 L 16.25 17.22 7.38 100 250 200 500 250 500 50<br />

HCP328HT 1200 240 T 16.25 17.22 7.38 100 250 — — — — 50<br />

HCP368H 1200 600 L 16.25 17.22 7.38 100 250 200 500 250 500 50<br />

3-Pole, Vertical Mount<br />

HCP367VJ400 1400 600 J 17.00 16.25 7.38 150 125 100 250 125 350 40<br />

HCP367VJ600s 1600 600 J 17.00 16.25 7.38 175 200 150 400 200 400 40<br />

HCP327VT 800 240 T 17.00 16.25 7.38 100 250 — — — — 50<br />

HCP367V 1800 600 L 17.00 16.25 7.38 100 250 200 500 250 500 50<br />

HCP328VT 1200 240 T 17.00 16.25 7.38 100 250 — — — — 50<br />

HCP368V 1200 600 L 17.00 16.25 7.38 100 250 200 500 250 500 50<br />

5 DISCONNECT<br />

SWITCHES<br />

Accessories<br />

Terminal Connectors (one lug per kit)<br />

Ampere Rating Catalog Number Connector Wire Range<br />

400–600A TA2K500 (2) #1 AWG–500 kcmil (Cu or AI)<br />

400–600A TC2K500 (2) #1 AWG–500 kcmil (Cu only)<br />

400–800A TA3K500 (3) #1 AWG–500 kcmil (Cu or AI)<br />

400–800A TC3K350 (3) #1 AWG–350 kcmil (Cu only)<br />

400-1200A TA4H500 (4) #2 AWG–500 kcmil (Cu or AI)<br />

400-1200A TA3H750 (3) 500–750 kcmil (Cu or AI)<br />

Auxiliary Switch Kits<br />

Contact<br />

Ampere Rating<br />

Shunt Trip Kit<br />

Maximum Voltage<br />

AC<br />

DC<br />

Control Voltage<br />

AC DC Catalog Number<br />

120 — HCPST120<br />

240 — HCPST240s<br />

277 — HCPST277<br />

480 — HCPST480s<br />

Switch<br />

Mounting<br />

Contacts<br />

Catalog<br />

Number<br />

15A 480 125 Left Pole 1NO/1NC A01HCPL4s<br />

15A 480 125 Right Pole 1NO/1NC A01HCPR4<br />

Switchboard Connection Strap Kit a<br />

Switch<br />

Ampere Rating Catalog Number<br />

400–1200A F6162D<br />

T Fuse Adapter Kits (one per pole)<br />

Catalog<br />

Number<br />

TFAK72<br />

TFAK75<br />

TFAK82<br />

Description<br />

1800A, 300V AC<br />

1800A, 600V AC<br />

1200A, 300V AC<br />

HCP Replacement Handle Kit<br />

(For use on all HCP switches)<br />

SW Ampere Rating Catalog Number<br />

400–1200A HCPHK<br />

Compression Lug Adapter Kit<br />

The use of this kit provides for the<br />

mounting of up to four lugs per phase.<br />

Each kit accepts lugs with (2) 3/8" diameter<br />

mounting holes on 1" centers. One<br />

kit per pole line or load is required. Lugs<br />

are not provided.<br />

*For inches / millimeters conversion, multiply inches by<br />

25.4.<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

a For horizontal mounting only in either 38" wide min<br />

switchboards or S5/F2 power panelboards.<br />

b Both 240 and 600V AC switches are also rated 250V DC<br />

max.<br />

Product Category VBSS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 5-27


Disconnect Switches<br />

Type HCP Switchboard Units<br />

Dimensions<br />

DISCONNECT<br />

SWITCHES<br />

5<br />

5-28<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Disconnect Switches<br />

Type TFP Fusible Pullouts<br />

Selection/Dimensions<br />

Features<br />

Type TFP Fusible Pullouts<br />

b 100 and 200 Ampere Disconnects<br />

b 240 Volt and 600 Volt Designs<br />

b Class T Fuses<br />

b Factory Installed Wire Connectors<br />

b U.L. Listed for applications up to<br />

200,000 Amps symmetrical at<br />

600 Volts<br />

b Physically interchangeable with<br />

Siemens Type QJ2, QJH2<br />

and QJ2-H<br />

b UL 1429, File No. E118778<br />

T-Fuse Pullouts<br />

2-Pole, 2-Fuse<br />

T-Fuse Pullout<br />

TFP223<br />

Maximum Ampere Catalog Connector<br />

Voltage Rating Number Wire Range 60/75°C a<br />

240 b 100 TFP223 (1 pc.) #6-300 kcmil Cu<br />

200 TFP224 (1 pc.) #4-300 kcmil Al<br />

5 DISCONNECT<br />

SWITCHES<br />

3-Pole, 3-Fuse<br />

240 b 100 TFP323<br />

200 TFP324 (1 pc.) #6-300 kcmil Cu<br />

600<br />

100 TFP363 (1 pc.) #4-300 kcmil Al<br />

200 TFP364<br />

Fuses — Not included. Consult local sales office for replacement parts.<br />

Fusible Pullouts Dimensions (inches*)<br />

Class T Pullout Mounting Hardware<br />

Catalog Number MSQJ (Includes 4 screws)<br />

For inches / millimeters conversion, multiply inches by 25.4.<br />

a Replacement terminal lug Catalog Number TA1Q300.<br />

b 240 bolt pullouts require 300 volt Class T fuses.<br />

Product Category HDSS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 5-29


Disconnect Switches<br />

Notes<br />

DISCONNECT<br />

SWITCHES<br />

5<br />

5-30<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Enclosed Circuit Breakers<br />

SPEEDFAX TM<br />

Section<br />

c o n t e n t s<br />

Enclosure Types 6-2<br />

Type 1<br />

Complete Assemblies<br />

Molded Case Circuit Breakers 6-3 – 6-6<br />

Enclosed Molded Case Switches 6-7<br />

Enclosures<br />

Type 1, Selection 6-8<br />

Type 1, Dimensions 6-9<br />

Type 3R, Selection 6-10<br />

Type 3R, Dimensions 6-11<br />

Types 4, 4X, 7 and 9, Selection/Dimensions 6-12<br />

Types 5, 12 and 12K, Selection/Dimensions 6-13<br />

Knockout and Hub Data 6-14<br />

Types 7, 9<br />

6 ENCLOSED<br />

CIRCUIT BREAKERS<br />

Types 5, 12, 12K<br />

Scan to connect<br />

online to the<br />

most up-todate<br />

version of<br />

this Section of<br />

SPEEDFAX.<br />

(Section was last modified on 10/16/20)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 6-1


Enclosed Circuit Breakers<br />

Enclosure Types<br />

General<br />

Type 3R<br />

Type 1<br />

ENCLOSED<br />

CIRCUIT BREAKERS<br />

6<br />

Types 7, 9<br />

Types 5, 12, 12K<br />

Type 1 — A general indoor, sheet-steel<br />

enclosure for use in normal<br />

atmospheres. Listed[ as service<br />

entrance equipment.<br />

Type 3R — An outdoor, sheet-steel<br />

enclosure providing protection against<br />

driving rain, sleet or snow. Listed as<br />

service entrance equipment.<br />

Types 7, 9 — Cast aluminum enclosure<br />

classified for explosion and fire hazard.<br />

Only enclosure for use in hazardous<br />

location. Class I; Group D–Class II;<br />

Groups E, F, and G–Class III.<br />

Types 4, 4X (not shown) — Stainless<br />

steel indoor or outdoor enclosure<br />

designed for use in areas where serious<br />

corrosion problems exist. They provide a<br />

degree of protection against windblown<br />

dust, rain, splashing water and hosedirected<br />

water. Meets NEMA Type 3, 4,<br />

4X, 12 and 13 requirements and UL 508<br />

Type 4 and 4X requirements.<br />

Types 5, 12 — A special-industry, sheetsteel<br />

enclosure for use in atmospheres<br />

containing particles of lint, dust, dirt,<br />

sawdust and other foreign matter.<br />

Type 12K — A semi-dusttight sheetsteel<br />

enclosure. Listed as service<br />

entrance equipment.<br />

6-2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Enclosed Circuit Breakers<br />

Complete Assemblies—Molded Case Circuit Breakers<br />

Revised on 02/28/19<br />

Selection<br />

Siemens Enclosed Circuit Breaker<br />

Complete Assemblies consist of a thermal<br />

magnetic molded case circuit breaker<br />

frame, trip unit, enclosure and standard<br />

line and load pressure wire connectors —<br />

assembled and shipped as one unit from<br />

the Siemens modification center. For<br />

service equipment or applications<br />

Catalog Numbering<br />

requiring a solid neutral, neutrals must be<br />

priced and ordered separately except as<br />

noted.<br />

To order, select the appropriate prefix<br />

from the table below and place it in front<br />

of the desired non-interchangeable trip or<br />

interchangeable trip circuit breaker catalog<br />

number. For circuit breaker selection,<br />

refer to SpeedFax Section 7.<br />

Note: Lead times are determined based<br />

on availability of components.<br />

Items marked with n in this<br />

section may contain components<br />

that are not normally stocked.<br />

Prefix<br />

Enclosure Type<br />

E1S<br />

Type 1 Surface<br />

E1F<br />

Type 1 Flush<br />

E3R<br />

Type 3R<br />

E12 Type 12<br />

E4X<br />

Type 4X Stainless Steel<br />

E46<br />

Type 4X 316 Stainless Steel<br />

Example:<br />

Catalog number E1SJD63B400 consists of:<br />

(1) JD63F400 frame<br />

(1) JD63T400 trip unit<br />

(1) J6N1 enclosure<br />

(6) TA2J6500 wire connectors<br />

Selection by Enclosure Type<br />

Circuit Breaker Complete Assembly Lug<br />

Neutrals<br />

Number<br />

Type 1<br />

Catalog<br />

Breaker<br />

Frame<br />

of<br />

Poles<br />

Ampere<br />

Rating<br />

Surface<br />

or Flush<br />

Type<br />

3R<br />

Type<br />

12<br />

Type<br />

4, 4X<br />

Number<br />

(included)<br />

Catalog Number<br />

QR2 2, 3 100-250 TA1QR300<br />

QRH2 2, 3 100-250 TA1QR300<br />

HQR2 2, 3 100-250 TA1QR300<br />

HQR2H 2, 3 100-250 TA1QR300<br />

NGG, 2, 3 15-30 3TC1Q1<br />

LGG a 2, 3 35-125 3TC1GG20<br />

HGG,<br />

3VA51<br />

3VA52<br />

3VA61<br />

3VA62<br />

ED2<br />

ED4<br />

ED6<br />

2, 3<br />

15-125<br />

100-250<br />

(order lugs separately)<br />

2, 3<br />

40-150<br />

100-250<br />

(order lugs separately)<br />

2 15-60 <br />

2 70-100 <br />

3 15-60 <br />

3 70-100 <br />

2 15-60 <br />

2 70-100 <br />

2 110-125 <br />

3 15-60 <br />

3 70-100 <br />

3 110-125 <br />

2 15-60 <br />

2 70-100 <br />

3 15-60 <br />

3 70-100 <br />

3 110-125 <br />

15-25A<br />

SA1E025<br />

30-60A<br />

Line LN1E100<br />

Load LD1E060<br />

70-100<br />

LN1E100<br />

110-125A<br />

TA1E6125<br />

Included with<br />

enclosure<br />

N125GG included<br />

with enclosure<br />

N250X included with<br />

enclosure<br />

Catalog Number<br />

W53045<br />

included with<br />

enclosure<br />

6 ENCLOSED<br />

CIRCUIT BREAKERS<br />

Available configuration<br />

— Not available<br />

a NEMA 4X Enclosure is non-metallic<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 6-3


Enclosed Circuit Breakers<br />

Complete Assemblies—Molded Case Circuit Breakers<br />

Selection<br />

Selection by Enclosure Type<br />

Circuit Breaker Complete Assembly Lug<br />

Neutrals<br />

Breaker<br />

Frame<br />

Number<br />

of<br />

Poles<br />

Ampere<br />

Rating<br />

Type 1<br />

Surface<br />

or Flush<br />

Type<br />

3R<br />

Type<br />

12<br />

Type<br />

4, 4X<br />

Catalog<br />

Number<br />

(included) Catalog Number<br />

2 15-60 <br />

HED4<br />

CED6<br />

2 70-100 <br />

2 n 110-125 <br />

3 15-60 <br />

3 70-100 <br />

3 110-125 <br />

2 n 15-100 —<br />

2 n 110-125 —<br />

3 15-100 —<br />

3n 110-125 —<br />

Refer to<br />

page 7-153<br />

Refer to<br />

page 7-153<br />

Catalog Number<br />

W53045<br />

included with<br />

enclosure<br />

DG 2, 3 50-150 TA1DG30 Catalog Number<br />

N250X Included with<br />

FG 2, 3 100-250 TAW1FG350 enclosure<br />

6<br />

ENCLOSED<br />

CIRCUIT BREAKERS<br />

Circuit Breaker<br />

Breaker<br />

Frame<br />

Number<br />

of<br />

Poles<br />

Ampere<br />

Rating<br />

Complete Assembly<br />

Type 1<br />

Surface or<br />

Flush<br />

Type<br />

3R<br />

Type<br />

12<br />

70-225 <br />

2 n<br />

FXD6,<br />

250 <br />

FD6<br />

70-225 <br />

3<br />

250 <br />

70-225 <br />

2 n<br />

HFD6,<br />

250 <br />

HFXD6<br />

70-225 <br />

3 n<br />

250 <br />

CFD6<br />

3 n<br />

70-225 —<br />

250 —<br />

JXD2<br />

2 n 200-400 <br />

3 200-400 <br />

JXD6,<br />

2 n 200-400 <br />

JD6<br />

3 200-400 <br />

HJD6,<br />

2 n 200-400 <br />

HJXD6 3 200-400 <br />

HHJD6, 2 n 200-400 <br />

HHJXD6 3 n 200-400 <br />

CJD6 3 n 200-400 —<br />

Lug<br />

Neutrals (not included)<br />

Catalog<br />

Type<br />

4, 4X<br />

Number<br />

(included) Catalog Number<br />

TA1FD350A<br />

TA2J6500<br />

N250 b<br />

W60992 a<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

Available configuration<br />

— Not available<br />

a Order catalog number W60993 neutral for type 4,<br />

4X enclosure or when a 200% neutral is required.<br />

b For 200% neutral order catalog number N2250<br />

6-4<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Enclosed Circuit Breakers<br />

Complete Assemblies—Molded Case Circuit Breakers<br />

Revised on 10/15/20<br />

Selection<br />

Selection by Enclosure Type<br />

Circuit Breaker Complete Assembly Lug Catalog<br />

Neutrals (Not Included)<br />

Breaker<br />

Frame<br />

Number<br />

of Poles<br />

Ampere<br />

Rating<br />

Type 1<br />

Surface<br />

Type<br />

3R<br />

Type<br />

12<br />

Type<br />

4, 4X<br />

Number<br />

(included)<br />

Catalog Number<br />

3VA53, 3VA54 2 200-600 <br />

3VA63, 3VA64 3 200-600 <br />

(order lugs separately) HN656ACB<br />

LXD6,<br />

LD6<br />

2 n<br />

3<br />

450-600<br />

450-600<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

HLD6,<br />

HLXD6<br />

HHLXD6 c ,<br />

HHLD6<br />

2 n 250-600 <br />

3 250-600 <br />

2 n 450-600 <br />

3 n 450-600 <br />

TA2J6500<br />

W60993 a<br />

CLD6 3 n 450-600 —<br />

3VA55, 3VA65 2/3 600-800 — (order lugs separately) HN656ACB<br />

LMXD6,<br />

LMD6<br />

2 n<br />

3 n<br />

500-800<br />

500-800<br />

<br />

<br />

<br />

<br />

<br />

<br />

—<br />

—<br />

HLMXD6 c ,<br />

HLMD6<br />

MXD6,<br />

MD6<br />

HMXD6 c ,<br />

HMD6<br />

2 n 500-800 —<br />

3 n 500-800 —<br />

2 n 500-800 —<br />

3 n 500-800 —<br />

2 n 500-800 —<br />

3 n 500-800 —<br />

CMD6 3 n 500-800 —<br />

TA3K500<br />

W63623 b<br />

6 ENCLOSED<br />

CIRCUIT BREAKERS<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

Available configuration<br />

— Not available<br />

a For 200% neutral in Type 1, 3R & 12 enclosures use<br />

neutral catalog number W63623.<br />

b For applications requiring 600MCM neutral conductors<br />

(max. 3 in & 3 out) use neutral catalog number<br />

W411239.<br />

c HHLXD6, HLMXD6 and HMXD6 are only available with<br />

3-pole breakers.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 6-5


Enclosed Circuit Breakers<br />

Complete Assemblies—Molded Case Circuit Breakers<br />

Revised on 10/31/19<br />

Selection<br />

Selection by Enclosure Type<br />

Circuit Breaker Complete Assembly Neutrals (Not Included)<br />

Lug<br />

Number<br />

Catalog<br />

Breaker of Ampere Type 1 Type Type Type Number<br />

Frame Poles Rating Surface 3R 12 4, 4X (included) Catalog Number<br />

NXD6<br />

2 n 900-1200 —<br />

3 900-1200 —<br />

2 n 800 — TA3K500<br />

2 n 900-1200 — for 800A<br />

ND6<br />

3 800 —<br />

2TA4N8500<br />

3 900-1200 —<br />

for 900-1200A<br />

HNXD6 3 900-1200 — 2-Pole W63623 b<br />

HND6<br />

2 n 800 —<br />

2 n 900-1200 — 3TA4N8500<br />

3 800 —<br />

for 900-1200A<br />

3-Pole<br />

3 900-1200 —<br />

CND6 3 n 900-1200 —<br />

PXD6 a 3 n 1200-1600 — — — TA5P600<br />

PD6 a 3 n 1200-1600 — — — TA5P600<br />

HPXD6 a 3 n 1200-1600 — — — TA5P600<br />

HPD6 a 3 n 1200-1600 — — — TA5P600<br />

CPD6 a 3 n 1200-1600 — — — TA5P600 N2000<br />

RXD6 a 3 1600-2000 — — — TC5R600<br />

RD6 a 3 n 1600-2000 — — — TC5R600<br />

HRXD6 a 3 n 1600-2000 — — — TC5R600<br />

HRD6 a 3 n 1600-2000 — — — TC5R600<br />

ENCLOSED<br />

CIRCUIT BREAKERS<br />

6<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

Available configuration<br />

— Not available<br />

a Not assembled — components shipped separately.<br />

Includes connect-all mounting assembly<br />

Catalog Number MB9301.<br />

b For applications requiring 600MCM neutral conductors<br />

(max. 3 in & 3 out) use neutral catalog number<br />

W411239.<br />

6-6<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Enclosed Circuit Breakers<br />

Complete Assemblies—Molded Case Circuit Switches<br />

Revised on 10/15/20<br />

Selection<br />

Selection by Enclosure Type<br />

Molded Case Switch Enclosure Type Lug<br />

Neutrals<br />

Number<br />

Type 1<br />

Catalog<br />

Breaker of<br />

Ampere Surface Type<br />

Type<br />

Type<br />

Number<br />

Frame Poles Rating or Flush 3R<br />

12<br />

4, 4X (included) Catalog Number<br />

Included with<br />

QR 3 250 TA1QR300<br />

enclosure<br />

2 n 100 Refer to<br />

ED2<br />

3 100 <br />

page 7-153<br />

100 <br />

2 n<br />

125 <br />

Refer to<br />

ED4<br />

100 <br />

page 7-153<br />

3<br />

125 <br />

Catalog Number<br />

100 <br />

W53045<br />

2 n<br />

125 — — — —<br />

included with<br />

Refer to<br />

ED6<br />

page 7-153<br />

enclosure<br />

100 <br />

3<br />

125 <br />

100 —<br />

CED6<br />

DG<br />

FG<br />

2 n<br />

125 —<br />

100 —<br />

3 n<br />

125 —<br />

2 150 <br />

3 150 <br />

2 250 <br />

3 250 <br />

Refer to<br />

page 7-153<br />

TA1DG30<br />

TAW1FG350<br />

Catalog Number<br />

N250X Included with<br />

enclosure<br />

3VA51<br />

3VA52<br />

2<br />

3<br />

125<br />

125<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Order lugs<br />

separately<br />

2 250 Order lugs<br />

3 250 <br />

separately<br />

Catalog Number<br />

N250X Included with<br />

enclosure<br />

Molded Case Switch Enclosure Type Lug<br />

Neutrals (not included)<br />

Catalog<br />

Breaker<br />

Frame<br />

Number<br />

of Poles<br />

Ampere<br />

Rating<br />

Type 1<br />

Surface<br />

Type 1<br />

Flush<br />

Type<br />

3R<br />

Type<br />

12<br />

Type<br />

4, 4X<br />

Number<br />

(included) Catalog Number<br />

FXD6<br />

2 250 <br />

3 250 <br />

TA1FD350A N250 c<br />

CFD6 3 n 250 —<br />

JXD2<br />

2 n 400 — <br />

3 400 — <br />

TA2J6500 W60992 b<br />

JXD6 3 400 — TA2J6500 W60992 b<br />

CJD6 3 n 400 — — TA2J6500 W60992 b<br />

3VA63,<br />

2 600 (order lugs<br />

3VA64<br />

3 600 <br />

separately)<br />

HN656ACB<br />

LXD6 3 600 — TA2J6500 W60993 d<br />

CLD6 3 n 600 — — TA2J6500 W60993 d<br />

3VA55 2/3 800 — <br />

(order lugs<br />

separately)<br />

HN656ACB<br />

MXD6 3 800 — —<br />

CMD6 3 n 800 — — —<br />

TA3K500 W63623 e<br />

NXD6 3 1200 — — —<br />

CND6 3 n 1200 — — —<br />

3TA4N8500 W63623 e<br />

PXD6 a 3 n 1600 — — — — TA5P500 N2000<br />

RXD6 a 3 n 2000 — — — — TC5R600 N2000<br />

6 ENCLOSED<br />

CIRCUIT BREAKERS<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

Available configuration<br />

— Not available<br />

a Not assembled — components shipped separately.<br />

Includes connect-all mounting assembly Catalog<br />

Number MB9301.<br />

b Order Catalog Number W60993 neutral for Type 4,<br />

4X enclosure or when a 200% neutral is required.<br />

c For 200% neutral order catalog number N2250<br />

d For 200% neutral in Type 1, 3R & 12 enclosures use<br />

neutral catalog number W63623.<br />

e For applications requiring 600 MCM neutral conductors<br />

(Max. 3 in and 3 out) use neutral catalog number<br />

W411239.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 6-7


Enclosed Circuit Breakers<br />

Enclosures — Type 1<br />

Revised on 03/31/20<br />

Selection<br />

Dimensions<br />

Figure 1 Figure 2 Figure 3<br />

Type 1<br />

Fig.<br />

No.<br />

Breaker<br />

Frame<br />

No.<br />

of<br />

Poles<br />

Max.<br />

Current<br />

Rating<br />

Catalog<br />

Number<br />

Weight<br />

Lb./Ship.<br />

Package<br />

K.O. Dimensions<br />

Dimensions (inches)<br />

6 Places 2 Places<br />

A B C D E F G H<br />

1 QP, QPH, HQP 1,2 0060 E0204ML1060S acg 016 7.1 5.1 3.3 5.8 3.8 1.1 — —<br />

1 QP, QPH, HQP 3 0100 E0303ML3100S acf 008 17.1 7.1 4.2 14.1 4.5 1.3 — —<br />

6<br />

ENCLOSED<br />

CIRCUIT BREAKERS<br />

1 BQ, BQH, HBQ 3 0100 EB3100S cf 032 17.1 7.1 4.2 14.1 4.5 1.3 — —<br />

1 NGG, HGG, LGG 2, 3 125<br />

GG0121FN<br />

GG0121SN<br />

12 20.0 8.7 4.0 16.0 6.0 1.3 — —<br />

2 ED2, ED4, ED6, HED4 2, 3 0100<br />

E2N1S ci 008 16.7 7.5 5.1 13.7 5.2 1<br />

E2N1F ci 008 17.5 8.5 5.1 13.7 5.2 1<br />

0.8, 1.1, 1.3 0.8, 1.1, 1.3<br />

2 ED4, ED6, HED4, CED6 2, 3 0125<br />

CED6N1S cei 14 21.4 7.6 5.1 18.2 5.2 1<br />

CED6N1F cei 14 22.2 8.5 5.1 18.2 5.2 1<br />

1.7, 2 1.7, 2<br />

2<br />

3<br />

3<br />

3<br />

3<br />

—<br />

FD6, FXD6, HFD6,<br />

HFXD6, HHFD6, CFD6<br />

JXD2, JD6,<br />

h<br />

JXD6, HJD6,<br />

HJXD6, HHJD6,<br />

HHJXD6, SJD6,<br />

SHJD6<br />

LD6, LXD6,<br />

h<br />

HLD6, HLXD6,<br />

HHLD6, HHLXD6,<br />

SLD6, SHLD6,<br />

SCJD6, SCLD6,<br />

CJD6, CLD6<br />

LMXD6, LMD6,<br />

HLMXD6, HLMD6<br />

MD6, MXD6, SMD6, h<br />

HMD6, HMXD6,<br />

SHMD6, ND6, NXD6,<br />

SND6, HND6, HNXD6,<br />

SHND6, CMD6,<br />

SCMD6, CND6, SCND6<br />

PD6, PXD6, HPD6, h<br />

HPXD6, CPD6, RD6,<br />

SPD6, SHPD6, RXD6,<br />

HRD6, HRXD6<br />

2, 3 0250<br />

F6N1S b<br />

F6N1F b 33 38.4 11.4 5.1 33.0 8.0<br />

1<br />

1.5<br />

1.1, 1.3, 1.7,<br />

2.0, 2.5, 3.0<br />

2, 3 0400 J6N1 b 120 41.2 22.4 10.7 37.0 18.2 2.1 — —<br />

2, 3 0600 LD6N1 b 101 46.0 22.4 10.7 42.0 18.2 2.1 — —<br />

2, 3 0800 LMD1 b 202 60.0 22.4 10.0 55.8 18.2 2.1 — —<br />

2–3 1200 MND61 b 202 60.0 22.4 10.0 55.8 18.2 2.1 — —<br />

3 2000 PRD6N1 n 350 90.0 32.0 28.0 — — — — —<br />

1.1, 1.3, 1.7,<br />

2.0, 2.5, 3.0<br />

For inches / millimeters conversion,<br />

see Application Data section.<br />

All above enclosures are suitable for use as service<br />

entrance devices<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

a Surface mounted, indoor. If flush mounting is required,<br />

replace suffix “S” in catalog number with suffix “F”.<br />

Also, if outdoor model required, use prefix “W”<br />

instead of “E”.<br />

b Neutral not included. Order as separate item from table<br />

on next page.<br />

c Neutral included in enclosure.<br />

d Surface mounted, indoor. If outdoor model is required,<br />

use prefix “W” instead of “E”. Not available in flush<br />

(“F”) model.<br />

e Use for 110-125 ampere ED4, ED6, or HED4<br />

circuit breakers.<br />

f Will not accept breaker with shunt trip.<br />

g Will not accept 2-pole GFP or breaker with shunt trip.<br />

h Includes 100% rated breakers.<br />

i Enclosure will accept shunt trip and other internal<br />

accessories except GFP.<br />

6-8<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Enclosed Circuit Breakers<br />

Enclosures — Type 1<br />

Revised on 10/15/20<br />

Selection<br />

Dimensions<br />

E<br />

F<br />

E<br />

F<br />

D<br />

L A D L<br />

A<br />

4X n .44<br />

MOUNTING HOLES<br />

C<br />

4X n .44<br />

MOUNTING HOLES<br />

C<br />

M<br />

M<br />

KNOCKOUT CODE<br />

CONDUIT SIZE<br />

A (TANGENTIAL) 2.00, 2.50, 3.00, 3.50<br />

KNOCKOUT CODE<br />

CONDUIT SIZE<br />

A (TANGENTIAL) 2.00, 2.50, 3.00, 3.50<br />

Figure 4 Figure 5<br />

K<br />

B<br />

TYPE 1S<br />

K<br />

B<br />

TYPE 1F<br />

Figure<br />

Number<br />

Breaker<br />

Frame<br />

No.<br />

of<br />

Poles<br />

Max.<br />

Current<br />

Rating<br />

Catalog<br />

Number<br />

Weight<br />

Lb./Ship.<br />

Package<br />

Dimensions (inches)<br />

A B C D E F G H J K L M N P<br />

4<br />

QR2, QR2H,<br />

HQR2, HQR2H 2–3 250 QR2N1S <br />

QR2N1F 40 31.4 9.1 5.6 25.3 6.1 2.4 4.6 2.2 2.1 4.9 32.2 9.6 — —<br />

4 3VA51 2,3 125<br />

4<br />

3VA52, 3VA61,<br />

3VA62<br />

2,3 250<br />

4 DG, FG 2–3 250<br />

5<br />

5<br />

3VA53, 3VA63,<br />

3VA54, 3VA64 2–3 600 3VAE6001S b<br />

3VAE6001F<br />

3VA55,<br />

3VA65<br />

Neutrals<br />

Neutral<br />

Catalog No.<br />

N250X<br />

2–3 800<br />

Enclosure<br />

Catalog Number<br />

QR2N1(S)(F)<br />

FG6N1(S)(F)<br />

3VAE250N1 (S)(F)<br />

3VAE125N1S <br />

3VAE125N1F 40 18.5 6.9 4.5 15.5 1.5 2.5 3.4 1.8 1.9 3.0 19.6 7.3 — —<br />

3VAE250N1S <br />

40 31.2 9.6 5.7 25.3 4.2 2.4 4.8 2.8 2.4 4.8 32.3 9.6 — —<br />

3VAE250N1F <br />

FG6N1S <br />

40 31.4 9.1 5.6 25.3 6.1 2.4 4.6 2.2 2.1 4.9 32.2 9.6 — —<br />

FG6N1F <br />

3VAE8001S<br />

3VAE8001F<br />

Neutral Cable Capacity<br />

and Wire Range<br />

6 AWG – 350 kcmil Cu/Al<br />

Grd. Lug 14 AWG –1/0 AWG Cu/Al<br />

N125X 3VAE125N1 (S)(F) 6 AWG – 350 kcmil Cu/Al<br />

N125GG GG0121SN/FN<br />

(1 pc.) #14-2/0 Cu/Al,<br />

(1 pc.) #1-300 kcmil Cu/Al<br />

Grd. Lug (1 pc.) #12 - #4 Cu/Al<br />

(3 pcs.)#12 - #10 Cu/Al<br />

W53045<br />

E2N1(S)(F)<br />

(1 pc.) #14–2 Cu/Al<br />

CED6N1(S)(F) d Grd. Lug (1 pc.) #14–8 Cu/Al<br />

N250 F6N1(S)(F)<br />

(1 pc.) #6–350 kcmil Cu/Al<br />

Grd. Lug (1 pc.) #14–2/0 Cu/Al<br />

HN656ACB<br />

W60992<br />

W60993<br />

W63623<br />

N2000<br />

3VAE6001S<br />

3VAE6001F<br />

3VAE8001S<br />

3VAE8001F<br />

J6N1<br />

LD6N1<br />

LMD1<br />

MND61<br />

PRD6N1<br />

1/0 - 600 kcmil Cu/Al<br />

Grd. Lug #6 - 300 kcmil Cu/Al<br />

(1 pc.) #1/0–750 kcmil Cu/Al or<br />

(2 pcs.) #1/0–300 kcmil Cu/Al<br />

Grd. Lug (1 pc.) #6–250 kcmil Cu/Al<br />

(2 pcs.) #1/0–600 kcmil<br />

Grd. Lug (1 pc.) #6–250 kcmil Cu/Al<br />

(4 pcs.) 250 kcmil–500 kcmil Cu/Ali<br />

Grd. Lug (1 pc.) #6–300 kcmil Cu/Al<br />

(6 pcs.) #3/0–750 kcmil Cu/Al<br />

Grd. Lug (2 pcs.) #3/0–750 Cu/Al<br />

68 44.9 22.1 6.8 40.0 16.0 3.1 — — — 14.3 42.8<br />

45.2<br />

111 60.0 22.5 10.2 52.0 16.0 3.2 — — — 14.3 60.5<br />

61.0<br />

For inches / millimeters conversion,<br />

see Application Data section.<br />

a Surface mounted, indoor. If flush mounting is required, replace suffix “S” in<br />

catalog number with suffix “F”. Also, if outdoor model required, use prefix<br />

“W” instead of “E”.<br />

b Neutral not included. Order as separate item from table on next page.<br />

c Surface mounted, indoor. If outdoor model is required, use prefix “W”<br />

instead of “E”. Not available in flush (“F”) model.<br />

d Use for 110-125 ampere ED4, ED6, or HED4 circuit breakers.<br />

e Will not accept breaker with shunt trip.<br />

f Also for use with Type 3R, 12, 12K & 4X enclosures<br />

(Catalog numbers F6N3R, F6N12, F6N12K & FD6SS4).<br />

g Also for use with Type 3R, 12 & 4X enclosures<br />

(Catalog numbers J6N3R, J6N12, & LD6SS4).<br />

h Also for use with Types 3R and 12 enclosures<br />

(Catalog numbers LD6N3R & LD6N12).<br />

i For 600 MCM neutral cable (3) in, (3) out (#4–600 kcmil Cu/Al)<br />

use catalog number W411239<br />

22.4<br />

23.0 — —<br />

23.0<br />

23.5 — —<br />

200% Neutrals (For Type 1, 3R, 4/4X and 12 Enclosures)<br />

Neutral<br />

Catalog No.<br />

Enclosure<br />

Catalog Number<br />

Neutral Cable Capacity<br />

and Wire Range<br />

N2250 F6N1(S)(F) f (2 pcs.) #4–350 kcmil Cu/Al<br />

Grd. Lug (1 pc.) #14–2/0 Cu/Al<br />

N2250X<br />

QR2N1(S)(F)<br />

FG6N1(S)(F)<br />

3VAE250N1 (S)(F)<br />

6 AWG – 350 kcmil Cu/Al<br />

Grd. Lug 6 AWG – 2/0 AWG Cu/Al<br />

W60993 J6N1 g (2 pcs.) #1/0–600 kcmil<br />

Grd. Lug (1 pc.) #6-250 kcmil Cu/Al<br />

W63623 LD6N1 h (4 pcs.) 250 kcmil–500 kcmil Cu/Al<br />

Grd. Lug (1 pc.) #6–300 kcmil Cu/Al<br />

HN678ACB<br />

3VAE6001S<br />

3VAE6001F<br />

3VAE8001S<br />

3VAE8001F<br />

1/0 - 600 kcmil Cu/Al<br />

Grd. Lug #6 - 300 kcmil Cu/Al<br />

6 ENCLOSED<br />

CIRCUIT BREAKERS<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 6-9


Enclosed Circuit Breakers<br />

Enclosures — Type 3R<br />

Revised on 10/15/20<br />

Selection<br />

Dimensions<br />

Figure 1 Figure 2 Figure 3<br />

Figure 4<br />

Type 3R<br />

Max.<br />

Current<br />

Rating<br />

Weight<br />

Lb./Ship.<br />

Package<br />

Dimensions (inches)<br />

Figure<br />

Number Breaker Frame<br />

No. of<br />

Poles<br />

Catalog Number<br />

A B C D E F G H<br />

2 QP, QPH 1, 2 60 W0204ML1060 e 28 8.1 5.1 4.3 — — — — —<br />

2 QPP, QPPH, HQPP 1-4 225 W0406ML1225CU d 24 23.1 10.5 4.3 20.0 7.5 1.9 5.2 —<br />

2 HQP, QPH, HQP 3 100 W0303ML3100 d 9 17.1 7.3 4.3 14.1 4.5 1.1 3.7 —<br />

2 BQ, BQH, HBQ 3 100 WB3100 d 9 17.1 7.3 4.3 14.1 4.5 1.1 3.7 —<br />

2 NGG, HGG, LGG 2, 3 125 GG0123RN 15 19.7 9.0 5.0 16.6 6.0 1.2 4.5 —<br />

6<br />

ENCLOSED<br />

CIRCUIT BREAKERS<br />

5<br />

5<br />

1<br />

1<br />

1<br />

4<br />

1<br />

ED2, ED4, ED6, HED4,<br />

HED6<br />

2, 3 100 E2N3R c 12 17.6 7.2 5.2 12.6 5.2 1.0 3.0 —<br />

ED2, ED4, ED6,<br />

CED6<br />

2, 3 125 CED6N3R c 16 22.3 7.2 5.2 17.3 5.2 1.0 3.0 —<br />

FD6, FXD6, HFD6,<br />

HFXD6, HHFD6,<br />

2, 3 250 F6N3R b 45 38.1 14.1 7.7 33.3 8.0 0.8 123.5 0.8<br />

HHFXD6, CFD6<br />

JXD2, JD6, JXD6,<br />

HJD6, HJXD6, HHJD6, 2, 3 400 J6N3R b 126 41.0 26.7 11.7 35.7 18.2 2.1 24.5 1.1<br />

HHJXD6, SJD6, SHJD6 f<br />

LD6, LXD6, LXD6H,<br />

HLD6, HLXD6, HHLD6,<br />

HHLXD6, CJD6, CLD6,<br />

2, 3 600 LD6N3R b 137 46.0 26.7 11.7 40.7 18.2 2.1 24.5 1.1<br />

SCJD6, SLD6, SHLD6 f<br />

LMXD6, LMD6,<br />

HLMXD6, HLMD6<br />

2, 3 800 LMD3R b 210 61.1 26.7 11.7 57.5 18.2 2.1 24.5 1.1<br />

MD6, MXD6, HMD6,<br />

HMXD6, CMD6, SMD6,<br />

SHMD6, SCMD6, ND6,<br />

NXD6, HND6, HNXD6,<br />

2, 3 1200 MND63 b 210 61.1 26.7 11.7 57.5 18.2 2.1 24.5 1.1<br />

SCND6 f<br />

CND6, SND6, SHND6,<br />

For inches / millimeters conversion,<br />

see Application Data section.<br />

Note: All above enclosures are suitable for use as service<br />

enterance equipment.<br />

a Does not include circuit breaker.<br />

Order circuit breaker separately.<br />

b Neutral not included. Order as separate item from table<br />

on next page.<br />

c Neutral included in enclosure.<br />

d Will not accept breaker with shunt trip.<br />

e Will not accept 2 pole GFP or breaker with shunt trip.<br />

f Includes 100% rated breakers.<br />

6-10<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Enclosed Circuit Breakers<br />

Enclosures — Type 3R<br />

Revised on 10/15/20<br />

Selection / Dimension<br />

Dimensions<br />

E<br />

F<br />

E<br />

F<br />

D<br />

L<br />

A<br />

D<br />

L<br />

A<br />

4X n .44<br />

MOUNTING HOLES<br />

M<br />

C<br />

4X n.34<br />

MOUNTING HOLE<br />

C<br />

M<br />

KNOCKOUT CODE<br />

CONDUIT SIZE<br />

A (TANGENTIAL) 2.00, 2.50, 3.00, 3.50<br />

K<br />

B<br />

K<br />

B<br />

Figure 5 Figure 6 Figure 7<br />

Figure 8<br />

Figure<br />

Number<br />

6<br />

Breaker<br />

Frame<br />

QR2, QR2H,<br />

HQR2, HQR2H<br />

No.<br />

of<br />

Poles<br />

Max.<br />

Current<br />

Rating<br />

Catalog<br />

Number<br />

Weight<br />

Lb./Ship.<br />

Package<br />

Dimensions (inches)<br />

KO Dim.<br />

A B C D E F G H J K L M G H<br />

2-3 250 QR2N3R3 40 31.4 9.1 5.6 25.3 6.1 2.4 4.6 2.2 2.1 4.9 32.2 9.6 — —<br />

6 3VA51 2,3 125 3VAE125N3R 40 18.5 6.9 4.5 15.5 1.5 2.5 3.4 1.8 1.9 3.0 19.4 7.3 — —<br />

6<br />

3VA52, 3VA61,<br />

3VA62<br />

2,3 250 3VAE250N3R 40 31.2 9.6 5.7 25.3 4.2 2.4 4.8 2.8 2.4 4.8 32.3 9.6 — —<br />

6 DG, FG 2-3 250 FG6N3R 40 31.4 9.1 5.6 25.3 6.1 2.4 4.6 2.2 2.1 4.9 32.2 9.6 — —<br />

7<br />

3VA53, 3VA54,<br />

3VA63, 3VA64<br />

2-3 600 3VAE6003R 68 44.9 22.1 6.7 40.0 16.0 3.1 — — — 14.7 45.8 22.4 — —<br />

8 3VA55, 3VA65 2-3 800 3VAE8003R 111 60.1 22.7 10.6 61.1 16.0 3.3 — — — 16.0 61.1 23.5 — —<br />

Neutrals d<br />

Neutral<br />

Catalog<br />

Number<br />

Enclosure<br />

Catalog<br />

Number<br />

Neutral Cable Capacity<br />

and Wire Range<br />

N125GG GG0123RN (1 PC.) #14-2/0 Cu/Al, (1 pc.) #1-300 kcmil Cu/Al<br />

Grd. Lug (1 pc.) #12 - #4 Cu/Al<br />

(3 pcs.)#12 - #10 Cu/Al<br />

N250X<br />

W53045 b<br />

QR2N3R3<br />

FG6N3R<br />

3VAE125N3R<br />

3VAE250N3R<br />

E2N3R<br />

CED6N3R c<br />

6 AWG – 350 kcmil Cu/Al<br />

Gnd. Lug 14 AWG –1/0 AWG Cu/Al<br />

(1 pc.) #14–2 Cu/Al<br />

Grd. Lug (1 pc.) #14–8 Cu/Al<br />

N250 d F6N3R (1 pc.) #6–350 kcmil<br />

Grd. Lug (1 pc.) #14–2/0 Cu/Al<br />

W60992 d J6N3R (1 pc.) #1/0–750 kcmil Cu/Al or<br />

(2 pcs.) #1/0–300 kcmil Cu/A<br />

Grd. Lug (1 pc.) #6–250 kcmil Cu/Al<br />

6 ENCLOSED<br />

CIRCUIT BREAKERS<br />

HN656ACB<br />

3VAE6003R<br />

3VAE8003R<br />

1/0 - 600 kcmil Cu/Al<br />

Grd. Lug #6 - 300 kcmil Cu/Al<br />

W60993 d LD6N3R (2 pcs.) #1/0–600 kcmil<br />

Grd. Lug (1 pc.) #6–250 kcmil Cu/Al<br />

W63623<br />

LMD3R<br />

MND63<br />

(4 pcs.) 250 kcmil–500 kcmil Cu/Ale<br />

Grd. Lug (1 pc.) #6–300 kcmil Cu/Al<br />

Hubs — see page 6-14.<br />

For inches / millimeters conversion,<br />

see Application Data section.<br />

a Neutral not included. Order as separate item from table<br />

on next page.<br />

b Neutral included in enclosure.<br />

c Use CED enclosure for all ED-frame 110-125<br />

ampere units.<br />

d 200% neutrals are also available. See listing on page 6-9.<br />

e For applications requiring 600MCM neutral conductors<br />

(3) in, (3) out (#4-600 kcmil Cu/Al) use neutral catalog<br />

number W41123.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 6-11


Enclosed Circuit Breakers<br />

Enclosures — Types 4, 4X, 7, and 9<br />

Revised on 10/15/20<br />

Selection / Dimensions<br />

Dimensions<br />

6<br />

ENCLOSED<br />

CIRCUIT BREAKERS<br />

Types 4 and 4X<br />

Breaker Frame<br />

Neutrals<br />

Neutral<br />

Catalog Number<br />

Figure 1A<br />

Figure 2 Types 7 and 9 e<br />

Breaker<br />

Frame<br />

Enclosure<br />

Catalog Number b<br />

No.<br />

of<br />

Poles<br />

For inches / millimeters conversion,<br />

see Application Data selection.<br />

Note: Above enclosures are suitable for use as service<br />

entrance equipment.<br />

■ Built to order. Allow 2–3 weeks for delivery.<br />

a Does not include circuit breaker.<br />

Order circuit breaker separately.<br />

Maximum<br />

Current<br />

Rating<br />

Figure 1B<br />

Catalog<br />

No. df<br />

Weight<br />

Lb./Ship.<br />

Package<br />

Neutral Cable Capacity<br />

and Wire Range<br />

N125GG4X GG0124XN #14-4 Cu / #12-2 Al<br />

W53045 c ED6SS4<br />

(1 pc.) #14–2 Cu/Al<br />

Grd. Lug (1 pc.) #14–8 Cu/Al<br />

N250X<br />

N250 df<br />

W60993 df<br />

HN656ACB<br />

QR2N4X, QR2N4X316, FG6N4X, FG6N4X316,<br />

3VAE125N4X, 3VAE125N4X316, 3VAE250N4X, 3VAE250N4X316<br />

FD6SS4<br />

LD6SS4<br />

See<br />

Fig.<br />

3VAE6004X, 3VAE6004X316<br />

3VAE8004X, 3VAE8004X316<br />

No.<br />

of<br />

Poles<br />

Figure 2<br />

Max.<br />

Weight<br />

Rating Catalog Number a Package<br />

Current<br />

Lb./Ship<br />

b Enclosures shipped with handle and breaker hardware<br />

packaged within enclosure.<br />

c Neutral included.<br />

d Neutral not included. Order as separate item.<br />

e Breather and drain option is by SPECIAL ORDER only —<br />

add $70.00 to list price.<br />

6 AWG – 350 kcmil CU / AL<br />

Grd. Lug 14 AWG –1/0 AWG CU / AL<br />

(1 pc.) #6–350 kcmil<br />

Grd. Lug (1 pc.) #14–2/0 Cu/Al<br />

(2 pcs.) #1/0–600 kcmil<br />

Grd. Lug (1 pc.) #6–250 kcmil Cu/Al<br />

1/0 - 600 kcmil Cu/Al<br />

Grd. Lug #6 - 300 kcmil Cu/Al<br />

Figure 3<br />

Dimensions (inches)<br />

A B C D E F G<br />

NGG, HGG, LGG i 1A 2–3 125 GG0124XN 19.25 17.25 09.5 — 3.63 3.63 18.75<br />

QR2, QR2H, HQR2, HQR2H 3 2–3 250 QR2N4X, QR2N4X316 42 32.1 10.4 5.7 35.4 6.0 16.0 —<br />

ED2, ED4, ED6, HED4 j 1A 3 125 ED6SS4 g 44 20.0 16.0 06.0 7.16 9.75 3.0 —<br />

3VA51 3 2,3 125<br />

3VAE125N4X 18.6 19.4 7.7 5.7 19.5 5.0 9.3 —<br />

3VAE125N4X316 18.6 19.4 7.7 5.7 19.5 5.0 9.3 —<br />

3VA52, 3VA61, 3VA62 3 2,3 250<br />

3VAE250N4X 22.3 32.2 10.2 5.8 32.9 6.0 18.0 —<br />

3VAE250N4X316 22.3 32.2 10.2 5.8 32.9 6.0 18.0 —<br />

DG, FG 3 2-3 250 FG6N4X, FG6N4X316 42 32.1 10.4 5.7 35.4 6.0 16.0 —<br />

FXD6, FD6, j HFD6, FXD6, FD6 1A 2–3 250 FD6SS4 g 106 36.0 24.0 08.0 09.16 11.75 3.0 —<br />

JXD2, JXD6, JD6, hj HJD6, HJXD6, HHJD6,<br />

HHJXD6, SJD6, SHJD6, LXD6, LD6, HLD6, 1A 2–3 600 LD6SS4 n g 145 42.0 30.0 10.0 11.16 13.75 3.0 —<br />

HLXD6, HHLD6, HHLXD6, SLD6, SHLD6<br />

3VA53, 3VA54, 3VA63, 3VA64 3 2–3 600 3VA6004X, 3VA6004X316 80 48.75 22.25 7.38 47.19 16.0 22.25 —<br />

3VA55, 3VA65 3 2–3 800 3VAE8004X, 3VAE8004X316 126 60.1 22.9 10.7 61.1 16.0 30.6 —<br />

Dimensions (inches)<br />

Knockouts<br />

Mounting Inside Outside Conduit Size<br />

A B C D E F G H K Std. Max<br />

ED2, ED4, 015–60 EA n 027 5.5 13.1 5.9 10.7 5.4 9.4 14.2 6.6 1.6 1.2 1.2<br />

ED6, HED4 2–3 070–100 EB n 032 6.0 18.0 6.5 16.0 5.6 9.8 19.3 6.7 2.0 2.0 2.0<br />

CED6 2–3 100 N/A<br />

FXD6, FD6, HFD6, HFXD6, CFD6 2–3 250 EC2 n 085 10.2 22.6 11.7 20.0 6.5 15.3 23.8 8.2 2.7 2.5 2.0<br />

JXD2, JXD6, JD6, SJD6, HJD6,<br />

HJXD6, HHJD6, HHJXD6, SHJD6<br />

2–3 200–350 EC4 n 085 10.2 22.6 11.7 20.0 6.5 15.3 23.8 8.2 2.7 2.5 3.0<br />

LXD6, LD6, SLD6, HLD6,<br />

HLXD6, HHLD6, HHLXD6, SHLD6<br />

2–3 600 ED6 n 190 11.8 40.7 13.3 37.8 7.8 18.1 46.6 9.8 3.6 4.0 4.0<br />

f For 400A max. 4/4x applications which require a 200%<br />

Neutral. See listing on page 6-9.<br />

g Suitable for use as Service Entrance device.<br />

h Includes 100% rated breakers.<br />

i Non-metallic enclosure.<br />

j 304 Stainless Steel enclosures.<br />

316 Stainless Steel enclosures.<br />

6-12<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Enclosed Circuit Breakers<br />

Enclosures — Types 5, 12 and 12K<br />

Revised on 10/15/20<br />

Selection / Dimensions<br />

Dimensions<br />

E<br />

F<br />

D<br />

L<br />

A<br />

4X n.34<br />

MOUNTING HOLE<br />

C<br />

M<br />

K<br />

B<br />

Figure 1 Figure 2 Figure 3 Figure 4 Figure 5<br />

Types 5, 12 and 12K<br />

Figure<br />

Number<br />

Breaker<br />

Frame<br />

No.<br />

of<br />

Poles<br />

Max.<br />

Current<br />

Rating<br />

Catalog<br />

Number <br />

Weight<br />

Lb./Ship.<br />

Package<br />

Dimensions (inches)<br />

A B C D E F G H J K L M<br />

1<br />

QR2, QR2H,<br />

HQR2, HQR2H<br />

2–3 0250 QR2N12 040 31.4 — 5.6 25.3 6.1 2.4 — — — — 32.2 9.6<br />

1 3VA51 2–3 125 3VAE125N12 40 18.5 — 4.5 15.5 1.5 2.5 — — — — 19.6 7.3<br />

1 3VA52, 3VA61, 3VA62 2–3 250 3VAE250N12 40 31.2 — 5.7 25.3 4.2 2.4 — — — — 32.3 9.6<br />

1 DG, FG 2–3 0250 FG6N12 040 31.4 — 5.6 25.3 6.1 2.4 — — — — 32.2 9.6<br />

2 ED2, ED4, ED6, HED4 2–3 0100 E2N12 ad 012 18.6 8.3 7.1 18 6.1 0.5<br />

2 CED6, ED2, ED4, ED6 2–3 0125 CED6N12 ad n 016 23.4 8.3 7.1 223⁄4 6.1 0.5<br />

2<br />

FXD6, FD6, FXD6,<br />

FD6, HFD6, CFD6<br />

2–3 0250 F6N12 ac 040 38.6 14.5 8.1 34.0 13.0 0.7<br />

3<br />

JXD2, JD6, JXD6, HJD6,<br />

HJXD6, HHJD6, HHJXD6, 2–3 0400 J6N12 104 41.5 21.6 11.9 37.2 20.4 0.6<br />

SJD6, SHJD6<br />

5<br />

3VA53, 3VA54,<br />

3VA63, 3VA64<br />

2–3 0600 3VAE60012 68 44.8 22.1 7.0 47.2 16.0 3.1 16.0 45.8 22.4<br />

3<br />

LD6, LXD6, HLD6,<br />

HLXD6, HHLD6, HHLXD6,<br />

SLD6, SHLD6, CJD6, CLD6,<br />

2–3 0600 LD6N12 n 104 46.5 21.6 11.9 42.2 20.4 0.6<br />

SCJD6, SCLD6<br />

5 3VA55, 3VA65 2–3 0800 3VAE80012 111 60.1 22.7 10.6 61.1 16.0 3.3 16.0 61.1 23.5<br />

4<br />

LMXD6, LMD6,<br />

HLMXD6, HLMD6<br />

2–3 0800 LMD12 n 220 60.0 37.4 10.0 0.4 3.0 2.0<br />

MD6, MXD6, SMD6, h<br />

4<br />

HMD6, HMXD6, SHMD6,<br />

ND6, NXD6, SND6, HND6,<br />

HNXD6, SHND6, CMD6,<br />

SCMD6, CND6, SCND6<br />

2–3 1200 MND612 c n 220 60.0 37.4 10.0 0.4 3.0 2.0<br />

6 ENCLOSED<br />

CIRCUIT BREAKERS<br />

Neutrals<br />

Neutral<br />

Catalog No.<br />

W53045 d<br />

N250X<br />

N250 cf<br />

Enclosure<br />

Catalog No. b<br />

E2N12<br />

CED6N12 e<br />

QR2N12<br />

FG6N12<br />

3VAE125N12<br />

3VAE250N12<br />

F6N12<br />

Neutral Cable Capacity<br />

and Wire Range<br />

(1 pc.) #14–2 Cu/Al<br />

6 AWG – 350 kcmil CU / AL<br />

Grd. Lug 14 AWG –1/0 AWG CU / AL<br />

(1 pc.) #6–350 kcmil<br />

Grd. Lug (1 pc.) #14–2/0 Cu/Al<br />

Neutrals (cont.)<br />

Neutral<br />

Catalog No.<br />

W60992 cf<br />

HN656ACB<br />

W60993 cf<br />

W63623 c<br />

Enclosure<br />

Catalog No. b<br />

J6N12<br />

3VAE60012<br />

3VAE80012<br />

LMD612<br />

MND612<br />

LD6SS4<br />

Neutral Cable Capacity<br />

and Wire Range<br />

(1 pc.) #1/0–750 kcmil Cu/Al or<br />

(2 pc.) #1/0–300 kcmil Cu/Al<br />

Grd. Lug (1 pc.) #6–250 kcmil Cu/Al<br />

1/0 - 600 kcmil Cu/Al<br />

Grd. Lug #6 - 300 kcmil Cu/Al<br />

(2 pcs.) #1/0–600 kcmil<br />

Grd. Lug (1 pc.) #6–250 kcmil Cu/Al<br />

(4 pcs.) 250 kcmil–500 kcmil Cu/Al<br />

Grd. Lug (1 pc.) #6–300 kcmil Cu/Al<br />

For inches/millimeters conversion, see Application Data section.<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

Note: All above enclosures are suitable for use as service<br />

entrance devices.<br />

a Catalog Number is for Type 12. If Type 12K with knockouts<br />

is required, add suffix “K” to catalog number.<br />

b Does not include circuit breaker.<br />

Order circuit breaker separately.<br />

c Neutral not included. Order as separate item.<br />

d Neutral included in enclosure.<br />

e Use CED enclosure for all ED-frame 110–125<br />

ampere units.<br />

f 200% neutrals are also available. See listing on page 6-9.<br />

g For 600 MCM neutral cable (3) in, (3) out (#4-600 kcmil Cu/<br />

Al) use catalog number W411239<br />

h Includes 100% rated breakers.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 6-13


Enclosed Circuit Breakers<br />

Enclosures — Knockout and Hub Data<br />

Revised on 06/30/19<br />

Dimensions<br />

Knockouts & Wire Bending Space<br />

Breaker<br />

Frame<br />

QP, QPH, HQP<br />

15–125<br />

BQ, BQH, HBP<br />

70–100<br />

QPP, QPPH, HQPP<br />

125–225<br />

Conduit Range<br />

Per Knockout<br />

Outside Dimensions<br />

(inches)<br />

Types 1, 12 and 12K<br />

Type 3R<br />

Number of Knockouts Per Panel (Type 4, 4X, 12 have no KO’s)<br />

Maximum<br />

Hub Size<br />

(inches)<br />

Top Bottom Side Back Bottom Side Back Type 3R<br />

Maximum Cable Sizes<br />

Recommended (Cu/Al)<br />

for Type 1, 3R, 4, 4X,<br />

12 & 12K Enclosures e f<br />

1<br />

⁄2, 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2 4 4 4 4 3 1 1 2 7 1 ⁄8" high encl. #6 c<br />

3<br />

⁄4, 1, 1 1 ⁄4 1 1 2 2 8 1 3 2<br />

1<br />

⁄2, 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2 — — — — 4 1 1 2 1 ⁄2 250 kcmil<br />

QR 1 1 ⁄2, 2, 2 1 ⁄2, 3 — — 2 2 — 1 1 3<br />

d<br />

NGG<br />

3<br />

⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2 — — — — — — — —<br />

ED2, ED4, ED6, HED4<br />

3VA51, 3VA52, 3VA61, 3VA62<br />

7<br />

⁄8, 1 1 ⁄8, 1 3 ⁄8, 1 3 ⁄4, 2 2 2 2 2 2 1 1 2<br />

d<br />

CED6<br />

7<br />

⁄8, 1 1 ⁄8, 1 3 ⁄8, 1 3 ⁄4, 2 2 a 2 a — — 2 — —<br />

7<br />

⁄8, 1 1 ⁄8, 1 3 ⁄8, 1 3 ⁄4, 2, 2 1 ⁄2 2 2 2 b 2 b — 1 1<br />

2 d (CFD6 only 300 kcmil)<br />

d<br />

FXD6, FD6, FXD6, FD6<br />

HFD6, CFD6<br />

JXD2, JXD6, JD6,<br />

HJD6, HJXD6, HHJD6,<br />

HHJXD6, SJD6, SHJD6<br />

LXD6, LD6, HLXD6,<br />

HLD6, HHLD6, HHLXD6,<br />

SLD6, SHLD6<br />

LMXD6, LMD6<br />

HLMXD6, HMLD6<br />

MD6, SMD6, HMD6<br />

ND6, SND6, HND6<br />

1 1 ⁄8, 1 3 ⁄8, 1 3 ⁄4, 2, 2 1 ⁄2, 3<br />

1 1 2 b 2 b 1 1 —<br />

1 1 — — 1 — —<br />

1 1 ⁄2, 2, 2 1 ⁄2, 3, 3 1 ⁄2, 4 1 1 2 4 — — — 4 (2) 600 kcmil<br />

1 1 ⁄2, 2, 2 1 ⁄2, 3, 3 1 ⁄2, 4 1 1 2 4 — — — 4 (2) 600 kcmil<br />

— — — — — — — — 4 (3) 600 kcmil<br />

— — —<br />

4 1 ⁄4 –<br />

4 3 ⁄4<br />

4 1 ⁄4 –<br />

4 3 ⁄4<br />

— — — 4<br />

4<br />

d<br />

(3) 600 kcmil or<br />

(4) 500 kcmil<br />

6<br />

ENCLOSED<br />

CIRCUIT BREAKERS<br />

Hubs (Type 3R)<br />

Breaker<br />

Frame<br />

QP, QPH, HQP,<br />

BQ, BQH, HBQ,<br />

NGG, HGG, LGG<br />

QPP, QPPH, HQPP,<br />

QR2, QRH2, QR2H, HQR2H<br />

ED2, ED4, ED6,<br />

HED4, HED6, HHED6,<br />

CED6, DG, 3VA51<br />

FXD6, FD6, HFD6, HFXD6,<br />

CFD6, FG, 3VA52, JXD2,<br />

JD6, JXD6, HJD6, HJXD6,<br />

LD6, LXD6, HLD6, HLXD6(A)<br />

3VA53, 3VA54, 3VA62,<br />

3VA63, 3VA64<br />

Conduit<br />

Size<br />

(inches)<br />

Catalog<br />

Number<br />

0 3 ⁄4 ECHS075<br />

1 ECHS100<br />

1 1 ⁄4 ECHS125<br />

1 1 ⁄2 ECHS150<br />

2 ECHS200<br />

1 1 ⁄4 ECHS125<br />

1 1 ⁄2 ECHS150<br />

2 ECHS200<br />

2 1 ⁄2 ECHS250<br />

0 3 ⁄4 ECHR075<br />

1 ECHR100<br />

1 1 ⁄4 ECHR125<br />

1 1 ⁄2 ECHR150<br />

2 ECHR200<br />

2 ECHV200<br />

2 1 ⁄2 ECHV250<br />

3 ECHV300<br />

3 1 ⁄2 ECHV350<br />

4 ECHV400<br />

Note: Enclosures for 250A max breakers<br />

have a hub provision on the rainshed.<br />

Enclosures for larger breakers (J, L, M<br />

& N frame) have blank top rainsheds.<br />

Drill or punch hole in the field to<br />

accommodate hub size desired.<br />

For inches / millimeters conversion,<br />

see Application Data section.<br />

a Type 12K only.<br />

b Type 12K enclosure has no knockouts this location.<br />

c 17 1 ⁄8" high enclosure provides sufficient wire bending<br />

space for all available CB lugs.<br />

d Sufficient wire bending space is provided for all<br />

available mechanical type CB lugs.<br />

e The use of cables larger than those listed below may<br />

violate NEC & UL wire bending space requirements.<br />

f The use of compression type connectors will violate<br />

NEC and UL wire bending space requirements.<br />

6-14<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

SPEEDFAX TM<br />

7Section<br />

Dual Function<br />

Circuit Breaker<br />

3VA<br />

molded<br />

case<br />

circuit<br />

breakers<br />

Scan to connect<br />

online to the<br />

most up-todate<br />

version of<br />

this Section of<br />

SPEEDFAX.<br />

QR Circuit Breakers<br />

NGB Circuit<br />

Breakers<br />

c o n t e n t s<br />

What’s New in Circuit Breakers 7-3 – 7-4<br />

Federal Specifications Classification 7-5<br />

Reference Guides 7-6 – 7-18<br />

Load Center Breakers<br />

Arc Fault and Ground Fault Breakers 7-19<br />

QP, 1 Inch Breakers 7-20<br />

QT, ½ Inch Breakers 7-21<br />

Special Application Breakers 7-22<br />

QD ¾ Inch Breakers 7-23<br />

Main and Branch Breakers 7-24 – 7-25<br />

Circuit Breaker Dimension Drawings 7-26<br />

Circuit Breaker Lug Data 7-27<br />

Surge Protection 7-28<br />

Panelboard Mounted Circuit Breakers<br />

BL 240V Breakers 7-29<br />

BL 240V Arc Fault and Ground Fault Breakers 7-30<br />

Special Application 240V Panelboard Mounted Breakers 7-31<br />

BQD 100A Frame 480/277V Breakers 7-32<br />

GB 125A Frame 600/347V Breakers 7-33<br />

NGB2 125A Frame 600/347V Breakers 7-34<br />

Internal Accessories for BQD and NGB Breakers 7-35<br />

3VA41 125A Frame 600/347V Breakers 7-36 – 7-37<br />

General Application Circuit Breakers<br />

BQ 240V Breakers 7-38<br />

BQXD 240V DIN Rail Mounting Breakers 7-39<br />

QR250 Frame 240V Breakers 7-40<br />

CQD 100A Frame 480/277V Breakers 7-42<br />

GG 125A Frame 600/347V Breakers 7-43<br />

Internal Accessories for CQD and NGG Breakers 7-44<br />

3VA Molded Case Circuit Breakers<br />

Catalog Numbering System 7-46<br />

3VA51 125A Thermal-magnetic Trip Circuit Breakers 7-48 – 7-52<br />

3VA61 150A Electronic Trip Circuit Breakers 7-53 – 7-55<br />

3VA52 250A Thermal-magnetic Trip Circuit Breakers 7-56 – 7-59<br />

3VA62 250A Electronic Trip Circuit Breakers 7-60 – 7-63<br />

3VA53 400A Thermal-magnetic Trip Circuit Breakers 7-64 – 7-65<br />

3VA63 400A Electronic Trip Circuit Breakers 7-66 – 7-68<br />

3VA54 600A Thermal-magnetic Trip Circuit Breakers 7-69<br />

3VA64 600A Electronic Trip Circuit Breakers 7-70 – 7-72<br />

3VA55 800A Thermal-magnetic Trip Circuit Breakers 7-73<br />

3VA65 800A Electronic Trip Circuit Breakers 7-74 – 7-75<br />

3VA66 1000A Electronic Trip Circuit Breakers 7-77 – 7-78<br />

3VA Molded Case Switch and Motor Circuit Protector 7-79 – 7-80<br />

3VA Internal Accessories 7-81<br />

3VA Breaker Operators 7-82 – 7-87<br />

3VA Connection Technology 7-88 – 7-96<br />

3VA Plug-in and Draw-out Technology 7-97 – 7-99<br />

3VA Communication and Testing/Commissioning Devices 7-100 – 7-103<br />

3VA Accessories and Electrical Requirements 7-104 – 7-109<br />

(continued on next page)<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

(Section was last modified on 10/16/20)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-1


Molded Case Circuit Breakers<br />

SPEEDFAX TM<br />

7Section<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

c o n t e n t s<br />

Sentron Thermal Magnetic and Electronic Circuit Breakers<br />

Catalog Numbering System 7-110<br />

ED 125A Frame 600V Breakers and Internal Accessories 7-111 – 7-113<br />

FD 250A Frame 600V Breakers and Internal Accessories 7-114 – 7-116<br />

JD/SJD 400A Frame Breakers and Internal Accessories 7-117 – 7-120<br />

LD/SLD 600A Frame Breakers and Internal Accessories 7-121 – 7-124<br />

LMD 800A Frame Breakers and Internal Accessories 7-125 – 7-127<br />

MD/SMD 800A Frame Breakers and Internal Accessories 7-128 – 7-131<br />

ND/SND 1200A Frame Breakers and Internal Accessories 7-132 – 7-135<br />

PD/SPD 1600A Frame Breakers and Internal Accessories 7-136 – 7-138<br />

RD 2000A Frame Breakers and Internal Accessories 7-139<br />

Magnetic Trip Only – ETI Motor Circuit Protectors 7-140 – 7-142<br />

Adjustable Instantaneous Magnetic Trip Settings 7-143 – 7-145<br />

Molded Case Switch – Circuit Disconnect 7-146<br />

Digital Solid State Sentron Sensitrip IV Series Trip Units 7-147 – 7-148<br />

WL Power Circuit Breakers 7-149 – 7-152<br />

Lug Information 7-153 – 7-155<br />

Breaker Modifications 7-156<br />

Internal Accessories – Feature Combinations 7-157<br />

External Accessories 7-160 – 7-165<br />

Unusual Operating Conditions 7-166 – 7-167<br />

VL Thermal Magnetic and Electronic Circuit Breakers<br />

Catalog Numbering System 7-169 – 7-170<br />

Technical Overview 7-171 – 7-172<br />

Trip Unit Overview 7-173 – 7-174<br />

DG 150A Frame and Internal Accessories 7-175 – 7-178<br />

FG 250A Frame and Internal Accessories 7-179 – 7-182<br />

JG 400A Frame and Internal Accessories 7-183 – 7-186<br />

LG 600A Frame and Internal Accessories 7-187 – 7-190<br />

MG 800A Frame and Internal Accessories 7-191 – 7-194<br />

NG 1200A Frame and Internal Accessories 7-195 – 7-198<br />

PG 1600A Frame and Internal Accessories 7-199 – 7-201<br />

Molded Case Switch 7-202<br />

Motor Circuit Protector 7-203<br />

VL 600 Volt DC Circuit Breakers 7-204<br />

External Accessories 7-205 – 7-217<br />

Accessory Locations 7-218<br />

Suffix for Factory Mounted Internal Accessories 7-219<br />

Technical Data 7-220 – 7-221<br />

Unusual Operating Conditions 7-222 – 7-223<br />

General Technical<br />

Series Short Circuit Ratings 7-224 – 7-234<br />

Sentron IEC 94702 AC Interrupting Ratings 7-235<br />

Typical Specifications 7-236<br />

Superseded Circuit Breakers 7-237 – 7-239<br />

Sentron Sensitrip<br />

7-2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Molded Case Circuit Breakers<br />

Revised on 05/31/18<br />

Introduction<br />

What’s new in molded case circuit breakers:<br />

New Sentron Sensitrip<br />

Sentron Sensitrip IV ETU Circuit Breakers with Integrated DAS /<br />

Maintenance Mode<br />

Design enhancements include:<br />

n Upgraded ETU for NEC 240.87 code compliance (Arc Energy Reduction)<br />

n Frame ratings from 400A to 1600A<br />

n Identical footprint, kAIC ratings and accessory offering as legacy<br />

Sensitrip III ETU breakers to ease integration / retrofit<br />

n Maintenance mode versions require customer-supplied 24V external<br />

power supply, maintenance switch and light<br />

The New Siemens QR Circuit Breaker<br />

Implemented in load centers, panelboards, switchboards, meter centers,<br />

and modular metering, the new QR breaker is the same form-factor/<br />

mounting as QJ breaker for easy retrofit.<br />

Design enhancements include:<br />

n Trip unit ratings from 100A to 250A.<br />

n Field installable internal accessories –<br />

shunt trip, aux switch or shunt/aux combo.<br />

n Two accessory pockets in 3-pole breakers.<br />

One accessory pocket in 2-pole breakers.<br />

n High in-rush current capability (450%).<br />

n Push-to-trip button.<br />

The Dual Function Circuit Breaker combines<br />

GFCI and AFCI, protecting against both Arc<br />

Faults and Ground Faults. This, along with the<br />

new Self-Test & Lockout feature, makes it the<br />

first in class in electrical safety for homeowners.<br />

n Faster Installation<br />

n Cost savings<br />

n Smaller Device<br />

n Self Test & Lockout feature as required by<br />

UL 943 effective June 2015<br />

The new<br />

Siemens<br />

3VA molded<br />

case circuit<br />

breakers<br />

n 125A thru 800A Thermal Magnetic<br />

Trip breakers<br />

n 150A thru 1000A Electronic Trip<br />

Circuit Breakers<br />

n Extensive and flexible accessories<br />

n Common internal accessories for<br />

the entire breaker family<br />

n Power metering with the series-8<br />

LCD electronic trip<br />

n Illuminated rotary handles show<br />

switch position<br />

n Smaller footprint than Sentron or<br />

VL breakers<br />

n Enhanced Tools and Resources<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

The Siemens GG circuit breaker is a compact, industrial<br />

design thermal magnetic breaker with valuable features<br />

for the global markets. These features include a design<br />

that meets multi-national standards, is suitable for DIN<br />

rail or base mounting without the need for adapters,<br />

and includes UL listed field installable accessories. The<br />

GG also has an over center toggle mechanism that is<br />

trip free and uses repulsion contact arm construction.<br />

Therefore, should a short circuit or tripping condition<br />

occur, the contacts are forced apart and the breaker<br />

cannot be held closed by means of the handle.<br />

NGB<br />

NGG<br />

HGG<br />

LGG<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-3


Molded Case Circuit Breakers<br />

Introduction<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Ordering<br />

In the FD through RD frames, you may<br />

order molded case circuit breakers three<br />

basic ways:<br />

b As separately ordered frames, trip<br />

units and lugs<br />

b As frame, trip unit and lugs ordered as<br />

one catalog number and shipped<br />

unassembled or assembled<br />

b As Frame and Trip Unit shipped<br />

assembled and with the trip unit made<br />

non-removable, in compliance with UL<br />

489 requirements that to be reverse<br />

fed the circuit breaker must not have<br />

an interchangeable trip unit.<br />

These two options are described in the<br />

following:<br />

Components Ordered Separately<br />

To get the components for a 3-pole, 400<br />

Amp standard interrupting circuit breaker,<br />

you would order the frame (JD63F400),<br />

the trip unit (JD63T400) and six lugs<br />

(TA2J6500). This option is normally<br />

useful only if you stock and use large<br />

volumes of product and wish to reduce<br />

your inventory cost. You may stock, for<br />

example, a smaller number of frames<br />

(JD63F400) and a variety of trip units<br />

(JD63T300, JD63T350, etc.) and<br />

assemble breakers as you need them.<br />

Frame, Trip Unit and Lugs<br />

Ordered Together<br />

If you order the catalog number<br />

JD63B400, you will receive a frame, a<br />

trip unit and 6 lugs in separate packages.<br />

By suffixing this number with “L” (e.g.<br />

JD63B400L), you will receive frame, trip<br />

unit and lugs assembled in one container.<br />

Pursuant to UL 489, a product ordered<br />

thus will have the markings “LINE” and<br />

“LOAD”, and may not be “reverse fed”<br />

(with power flowing from the “OFF” end<br />

of the breaker toward the “ON” end).<br />

Non-Interchangeable Trip Breakers<br />

If you place an “X” after the frame size<br />

designator (e.g. JXD63B400), you will<br />

receive a frame and trip unit assembled,<br />

with the trip unit made non-removable.<br />

If you suffix an “L” to this catalog<br />

number (e.g. JXD63B400L), you will<br />

receive the breaker, non-removable trip<br />

unit and lugs assembled. Unless you<br />

anticipate a specific need to change the<br />

breaker’s ampere rating in the future,<br />

this is the preferred ordering method, as<br />

the products are assembled to Siemens’<br />

specifications in our factories. These<br />

breakers are suitable for use reverse fed<br />

according to UL 489, since the trip unit is<br />

not removable.<br />

The smaller frames (QJ, ED and below)<br />

do not have removable trip units, and<br />

consequently are shipped only as<br />

assembled products. To add lugs,<br />

see the ordering instructions on<br />

each product’s catalog page.<br />

500V DC Wiring Configuration<br />

Connecting Breakers for DC<br />

Application<br />

Most Siemens thermal magnetic trip<br />

MCCBs are applicable on direct current<br />

(dc) systems. Generally, for 250 V dc<br />

systems a two pole breaker is used,<br />

with one pole on each leg of the supply<br />

circuit. For three pole breakers applied on<br />

500 V undergrounded DC systems, it is<br />

important to connect the power supply<br />

“zig-zag” through the breaker as shown<br />

in the figure below. This assures that the<br />

Voltage between phases on the breaker<br />

terminals is uniformly distributed.<br />

See below for an alternative connection<br />

diagram. For a list of Sentron breakers<br />

with the DC ratings, please refer to<br />

pages 7-12 to 7-16.<br />

300 V<br />

MAX.<br />

300 V<br />

MAX.<br />

Load/Carga/<br />

Charge<br />

7-4<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Molded Case Circuit Breakers<br />

Federal Specification Classification<br />

Revised on 05/31/18<br />

Reference<br />

W-C-375C/GEN<br />

Class<br />

Interrupting Rating<br />

Symmetrical<br />

Amperes a Volts AC 60HZ<br />

Poles Range of Current Trip c the Indicated Class Level)<br />

Breaker Type<br />

(All Circuit Breakers Meet or Exceed<br />

10a b 5,000 120/240 1 or 2 15–100 QP, BQ, QT, BL<br />

10b 5,000 240 2 or 3 15–100 QP, BQ, BQD, CQD, BL<br />

11a 7,500 120 1 15–100 QP, BQ, BQD, CQD, BL<br />

11b 7,500 240 2 or 3 15–100 QP, BQ, BQD, CQD, BL<br />

12a b 10,000 120/240 1 or 2 15–100 QP, BQ, QT, ED2, BL<br />

12b 10,000 240 2 or 3 15–225 QP, BQ, QJ2, ED2, BQD, CQD, BL<br />

12c 10,000 277 1 15–100 bqd, cqd, NGG, NGB, NEG, NEB<br />

13a 14,000 277 1 15–100 ed4, bqd, cqd, NGG, NGB, NEG, NEB<br />

13b 14,000 277/480 1, 2, or 3 15–100 ed4, bqd, cqd<br />

14a 22,000 120/240 1 or 2 15–100 qph, bqh, blh<br />

14b 22,000 240 2 or 3 70–400 qjh2, qj2-h, bqh, bqd, cqd, blh<br />

15a 65,000 120/240 1 or 2 15–100 hqp, hbq, ed4, hed4, NGG, NGB<br />

15b 65,000 240 2 or 3 15–225<br />

ed6, ed4, fxd6, fd6, hed4, bqd, cqd, hqj2h,<br />

NGG, NGB, NEG, NEB<br />

16a 100,000 480 2 or 3 15–225 cfd6, ced6<br />

16b 100,000 600 2 or 3 15–600 ced6, cfd6, cjd6, scjd6, cld6, scld6<br />

17a 200,000 600 2 or 3 70–2000 —<br />

18,000 240<br />

18a<br />

14,000 480 2 or 3 15–125 ed6, hed6, hhed6<br />

14,000 600<br />

22,000 240<br />

19a 18,000 480 2 or 3 70–225 fxd6, fd6, cfd6, hfd6<br />

14,000 600<br />

25,000 240<br />

20a 22,000 480 2 or 3 70–225 fxd6-a, fd6-a, cfd6, hfd6<br />

22,000 600<br />

hfd6, cfd6, jxd6(A), JD6(A), SJD6-B, hjd(a),<br />

42,000 240 hjxd6(a), hhjd6, SHJD6-B, cjd6, SCJD6-B,<br />

21a 30,000 480 2 or 3 70–800 lxd6(a), ld6(a), SLD6-B, hld6(a), hlxd6(a),<br />

22,000 600 hhld6, SLD6-B, SHLD6-B, cld6, SCLD6-B,<br />

lmd6, lmxd6, hlmd6, hlmxd6, md6, mxd6,<br />

SMD6-B, hmd6, hmxd6, SHMD6-B, cmd6, SCMD6-B<br />

65,000 240<br />

22a 25,000 480 2 or 3 15–125 ced6, ed6, hed6, hhed6, fxd6-a, fd6-a<br />

18,000 600<br />

HHED6, FXD6-A, FD6-A, hfd6, hhfd6, cfd6,<br />

Jd6(a), jxd6(a), SJD6-B, hjd6(a), hjxd6(a),<br />

SHJD6-B, hhjd6, hhjxd6, cjd6, SCJD6-B,<br />

65,000 240 lxd6(a), ld6(a), SLD6-B, hld6(a), hlxd6(a),<br />

23a 35,000 480 2 or 3 70–1200 SHLD6-B, hhld6, hhlxd6, cld6, SCLD6-B,<br />

25,000 600 lmd6, lmxd6, hlmd6, hlmxd6, md6, mxd6,<br />

SMD6-B, hmd6, hmxd6, SHMD6-B, cmd6, SCMD6-B,<br />

nd6, nxd6, snd6-B, hnd6, hnxd6, shnd6-B,<br />

cnd6, scnd6-B<br />

65,000 240<br />

24a 50,000 480 2 or 3 1200–2000<br />

42,000 600<br />

125,000 240<br />

25a 80,000 480 2 or 3 600–4000<br />

60,000 600<br />

PD6, PXD6, HPD6, HPXD6, CPD6<br />

RD6, RXD6, HRD6, HRXD6, SPD6-B, SHPD6-B<br />

HHLD6, CLD6, CMD6, CND6<br />

SCLD6-B, SCMD6-B, SCND6-B, CPD6<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Applicable Standards<br />

UL489 — Molded Case Circuit Breakers<br />

and Circuit Breaker Enclosures.<br />

UL486A — Wire Connectors and<br />

Solderless Lugs for use with copper wire<br />

UL486B — Wire Connectors and<br />

Solderless Lugs for use with<br />

aluminum wire<br />

UL943 — Ground Fault Interrupters (for<br />

personnel protectors)<br />

UL1087 — Molded Case Switches<br />

UL50 — Cabinets and Boxes<br />

UL869 — Service Equipment<br />

NEMA AB-1 — Molded Case Circuit<br />

Breakers and Molded Case Switches<br />

CSA–C22.2 No. 5, C22.2 No. 14<br />

Note:<br />

(A) Molded case circuit breakers are designed and tested<br />

in accordance to applicable portions of UL489 and meet<br />

application requirements of the National Electric Code.<br />

Unless marked otherwise, circuit breakers are 80% duty rated.<br />

(B) Molded case circuit breakers are to be connected with 60 or<br />

75°C wire for circuit breakers having a rated ampacity of<br />

100 amperes or less. Circuit breakers having a rated ampacity<br />

greater than 100 amperes shall only be cabled with 75°C<br />

cable unless otherwise indicated on the circuit breaker<br />

label. Exceptions to this rule are outlined in the article<br />

110-14 C(1)(2) of the 2005 National Electric Code.<br />

a Interrupting ratings are not limited to the values or groups of<br />

values listed. However, the values listed are minimum values<br />

for the class specified.<br />

bSingle-unit or duplex construction must be specified.<br />

cUse minimum frame size for ampere rating.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-5


Molded Case Circuit Breakers<br />

Reference Guide<br />

Revised on 11/30/19<br />

Selection/Application<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Thermal-Magnetic Trip Breakers<br />

Plug-In Breakers<br />

Panelboard Breakers<br />

QT<br />

QP,<br />

QPP a QPH,<br />

QPPH a HQP,<br />

HQPP a HQPPH a QPJ g BL h BLH HBL<br />

Page 7-21 7-22, 7-24 7-22, 7-24 7-20, 7-24 7-20, 7-24 7-24 7-29 7-29 7-29<br />

Poles 1, 2 1, 2, 3 1, 2, 3 1, 2, 3 e 2 2, 3 1,2,3 1,2,3 1,2,3<br />

Amperes 15-50 10-125 10-125 10-125 e 100-225 150-200 10-125 15-125 15-100<br />

1 Pole<br />

120/240 120/240 120/240<br />

120/240 120/240 120/240 120/240 120/240 120/240<br />

Volts (50/60 Hz)<br />

2 Pole 120/240 120/240 120/240<br />

3 Pole — 240 240 240 240 240 240 240 240<br />

120V 10,000 10,000 22,000 65,000 — — 10,000 22,000 65,000<br />

240V 10,000 10,000 22,000 65,000 100,000 10,000 10,000 22,000 65,000<br />

277V — — — — — — — — —<br />

UL<br />

347V — — — — — — — — —<br />

480/277V — — — — — — — — —<br />

480V — — — — — — — — —<br />

AC<br />

600/347V — — — — — — — — —<br />

Interrupt<br />

600V — — — — — — — — —<br />

Rating<br />

lCU — — — — — — — — —<br />

Symmetrical<br />

2-Pole<br />

220/<br />

lCS — — — — — — — — —<br />

RMS<br />

240V<br />

lCU — — — — — — — — —<br />

Amperes<br />

2, 3-Pole<br />

lCS — — — — — — — — —<br />

50/ 415V<br />

lCU — — — — — — — — —<br />

60Hz i 2, 3-Pole<br />

lCS — — — — — — — — —<br />

IEC<br />

lCU — — — — — — — — —<br />

2-Pole<br />

947-2 380/<br />

lCS — — — — — — — — —<br />

500V<br />

2-Pole<br />

lCU — — — — — — — — —<br />

lCS — — — — — — — — —<br />

2, 3-Pole<br />

lCU — — — — — — — — —<br />

lCS — — — — — — — — —<br />

DC 125/250 V DC Interrupting Rating 2-Pole — — — — — — — — —<br />

3-Pole — — — — — — — — —<br />

Ratings<br />

Dimensions<br />

in Inches<br />

Overcurrent<br />

Devices<br />

Accessories &<br />

Modifications<br />

Individual<br />

Enclosures<br />

Height<br />

10-50A — 2.87 2.87 — — — 3.56 3.56 3.75<br />

10-60A 3.12 — — — — — — — —<br />

55-125A — 3.12 3.12 3.12 3.12 3 g 3.75 3.75 3.75<br />

1-Pole 1.00 1.00 1.00 1.00 — — 1.00 1.00 1.00<br />

Width<br />

2-Pole 2.00 2.00 2.00 a 2.00 4.00 g 2.00 2.00 2.00<br />

3-Pole 3.00 3.00 3.00 3.00 — 3.00 g 3.00 3.00 3.00<br />

Depth 2.06 2.37 2.37 2.37 2.37 2.34 2.37 2.37 2.37<br />

Thermal and Fixed magnetic Trip u u u u u u u u u<br />

Thermal and Adjustable Magnetic trip — — — — — — — — —<br />

Adjustable Magnetic trip only — — — — — — — — —<br />

Motor Circuit Protector — — — — — — — — —<br />

Molded Case Switch — ud — — — — — — —<br />

Undervoltage Trip — — — — — — — — —<br />

Shunt Trip — ud ud uf uf — u u u<br />

Auxilary Switch — — — — uf — u u u<br />

Alarm Switch — — — — — — — — —<br />

Mechanical Interlock — — — — — — — — —<br />

Fungus Proofing (ref. page 7-156) — — — — — — u u u<br />

Type 1 - Indoor Surface u u u u u —<br />

Type 1 - Indoor, Flush — u u u u —<br />

Type 3R - Outdoor-Rainproof — u u u u —<br />

Q3100<br />

B120<br />

B220H<br />

B320HH<br />

For inches / millimeters conversion, see Application Data section.<br />

For Plug-in Breakers, see Load Centers & Circuit Breakers section.<br />

aTypes QPP, QPPH, HQPP and HQPPH are special 2-pole<br />

configurations for metering equipment. Amperage range =<br />

125–225A, width = 4 in.<br />

bSingle pole breakers available in ratings 10–70A only.<br />

c125A, 2-pole 120/240V AC only.<br />

dNot applicable to types QPP and QPPH.<br />

e Single pole circuit breakers available in ratings 15-70A only,<br />

125A available as a 2-pole only.<br />

f Not applicable to type HQPP and HQPPH.<br />

g Fits only Siemens EQIII load centers. Breaker is 2 or 3<br />

poles wide.<br />

h 10A, 1-pole & 2-pole 120/240V AC only.<br />

i Applicable for 15-30A breakers only.<br />

7-6<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Molded Case Circuit Breakers<br />

Reference Guide<br />

Revised on 09/30/20<br />

Selection/Application<br />

Thermal-Magnetic Trip Breakers<br />

Panelboard Breakers<br />

BQD,<br />

BQD6 a NGB<br />

NGB2 b HGB<br />

HGB2 b LGB<br />

LGB2 b 3VA41<br />

SEAB<br />

3VA41<br />

MEAB<br />

3VA41<br />

HEAB<br />

Page 7-32 7-33 7-33 7-33 7-36, 7-37 7-36, 7-37 7-36, 7-37<br />

Poles 1,2,3 1,2,3 1,2,3 1,2,3 1, 2, 3 1, 2, 3 1, 2, 3<br />

Amperes 15-100 15-125 15-125 15-125 15-125 15-125 15-125<br />

1 Pole 277 347 347 347 347 347 347<br />

Volts (50/60 Hz)<br />

2 Pole 480/277 600/347 600/347 600/347 600/347 600/347 600/347<br />

3 Pole 480/277 600/347 600/347 600/347 600/347 600/347 600/347<br />

120V 65,000 — — — — — —<br />

240V 65,000 100,000 100,000 100,000 65,000 85,000 150,000<br />

277V 14,000 25,000 35,000 65,000 25,000 35,000 65,000<br />

347V 10,000 14,000<br />

14,000 14,000<br />

22,000 b b<br />

65,000<br />

14,000 18,000 25,000<br />

UL<br />

480/277V 14,000 25,000 35,000 65,000 25,000 35,000 65,000<br />

Ratings<br />

Dimensions<br />

in Inches<br />

Overcurrent<br />

Devices<br />

Accessories &<br />

Modifications<br />

Individual<br />

Enclosures<br />

AC<br />

DC<br />

Height<br />

Width<br />

Interrupt<br />

Rating<br />

Symmetrical<br />

RMS<br />

Amperes<br />

IEC<br />

947-2<br />

50/<br />

60Hz<br />

220/<br />

240V<br />

380/<br />

415V<br />

500V<br />

125/250 V DC Interrupting<br />

Rating<br />

480V —<br />

—<br />

25,000 b —<br />

35,000<br />

b<br />

600/347V 10,000 14,000<br />

14,000<br />

—<br />

b<br />

65,000<br />

25,000 35,000 65,000<br />

14,000<br />

22,000 b b<br />

25,000<br />

14,000 18,000 25,000<br />

600V — — — — — — —<br />

lCU 18,000 — — — — — —<br />

2-Pole<br />

lCS 9,000 — — — — — —<br />

lCU 65,000 — — — — — —<br />

2, 3-Pole<br />

lCS 33,000 — — — — — —<br />

lCU — — — — — — —<br />

2-Pole<br />

lCS — — — — — — —<br />

lCU 18,000 — — — — — —<br />

2, 3-Pole<br />

lCS 9,000 — — — — — —<br />

lCU — — — — — — —<br />

2-Pole<br />

lCS — — — — — — —<br />

2, 3-Pole lCU — — — — — — —<br />

lCS — — — — — — —<br />

2-Pole 14,000 14,000 14,000 14,000 — — —<br />

3-Pole — — — — — — —<br />

10-50A 4.50<br />

5.00<br />

5.00<br />

5.00<br />

5.40 b 5.40 b 5.40 b — — —<br />

10-60A — — — — — — —<br />

55-125A 4.50<br />

5.00<br />

5.00<br />

5.00<br />

5.40 b 5.40 b b<br />

5.40<br />

5.1 5.1 5.1<br />

1-Pole 1.00 1.00 1.00 1.00 1.0 1.0 1.0<br />

2-Pole 2.00 2.00 2.00 2.00 2.0 2.0 2.0<br />

3-Pole 3.00 3.00 3.00 3.00 3.0 3.0 3.0<br />

Depth 2.69 2.71 2.71 2.71 3.6 3.6 3.6<br />

Thermal and Fixed magnetic Trip u u u u u u u<br />

Thermal and Adjustable Magnetic trip — — — — — — —<br />

Adjustable Magnetic trip only — — — — — — —<br />

Motor Circuit Protector — — — — — — —<br />

Molded Case Switch — — — — — — —<br />

Undervoltage Trip — — — — √ √ √<br />

Shunt Trip u u u u √ √ √<br />

Auxilary Switch u u u u √ √ √<br />

Alarm Switch u u u u √ √ √<br />

Mechanical Interlock — — — — √ √ √<br />

Fungus Proofing (ref. page 7-156) u u u u<br />

Type 1 - Indoor Surface<br />

Type 1 - Indoor, Flush<br />

Type 3R - Outdoor-Rainproof<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

NGB1B030B<br />

For inches / millimeters conversion, see Application Data section.<br />

For Plug-in Breakers, see Load Centers & Circuit Breakers section.<br />

aBQD6 CSA certified 10,000A @ 600Y/347V 15–70A only.<br />

b When two numbers are shown for the xGB/xGB2 column,<br />

the top rating is for xGB and the bottom rating for xGB2.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-7


Molded Case Circuit Breakers<br />

Reference Guide<br />

Revised on 11/30/19<br />

Selection/Application<br />

Thermal-Magnetic Trip Breakers<br />

General Purpose Breakers<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

BQ BQH HBQ QR2 QRH2 HQR2 HQR2H<br />

Page 7-38 7-38 7-38 7-40 7-40 7-40 7-40<br />

Poles 1, 2, 3 1, 2, 3 1, 2, 3 2, 3 2, 3 2, 3 2, 3<br />

1-Pole 15–70 15–70 15–50 — — — —<br />

Amperes, Continuous<br />

2-Pole 15–125 15–100 15–70 100–250 100–250 100–250 100–250<br />

3-Pole 15–100 15–100 15–100 100–250 100–250 100–250 100–250<br />

1-Pole 120/240 120/240 120/240 — — — —<br />

Volts (50/60 Hertz)<br />

2-Pole 240 240 240 240 240 240 240<br />

3-Pole 240 240 240 240 240 240 240<br />

120V 10,000 22,000 65,000 — — — —<br />

UL<br />

240V 10,000 22,000 65,000 10,000 25,000 65,000 100,000<br />

480V — — — — — — —<br />

600/347V — — — — — — —<br />

AC<br />

Icu — — — — — — —<br />

1-Pole<br />

220/<br />

Ics — — — — — — —<br />

240V<br />

Icu — — — — — — —<br />

2,3-Pole<br />

Ics — — — — — — —<br />

Ratings<br />

DC<br />

Dimensions<br />

in inches<br />

Overcurrent<br />

Devices<br />

Accessories and<br />

Modifications<br />

Individual<br />

Enclosures<br />

Interrupt Rating Symmetrical RMS Amperes<br />

IEC<br />

947-2<br />

50/<br />

60Hz<br />

380/<br />

415V<br />

500V<br />

1-Pole<br />

2,3-Pole<br />

1-Pole<br />

2,3-Pole<br />

Icu — — — — — — —<br />

Ics — — — — — — —<br />

Icu — — — — — — —<br />

Ics — — — — — — —<br />

Icu — — — — — — —<br />

Ics — — — — — — —<br />

Icu — — — — — — —<br />

Ics — — — — — — —<br />

Volts — 2-Pole — — — — — — —<br />

Interrupting Rating — DC Amperes — — — — — — —<br />

15–50A 3.75 3.75 4.00 — — — —<br />

Height<br />

55–125A 4.00 4.00 4.00 — — — —<br />

60–225A — — — 7.00 7.00 7.00 7.00<br />

1-Pole 1.00 1.00 1.00 — — — —<br />

Width<br />

2-Pole 2.00 2.00 2.00 3.00 3.00 3.00 3.00<br />

3-Pole 3.00 3.00 3.00 4.50 4.50 4.50 4.50<br />

Depth 2.37 2.37 2.37 2.53 2.53 2.53 2.53<br />

Thermal and Fixed Magnetic Trip u u u u u u u<br />

Molded Case Switch u — — — — — u <br />

Undervoltage Trip — — — — — — —<br />

Shunt Trip u u u u u u u<br />

Auxiliary Switch u u u u u u u<br />

Alarm Switch — — — — — — —<br />

Mechanical Interlock — — — u u u u<br />

Fungus Proofing (ref. page 7-156) u u u u u u u<br />

Type 1 — Indoor Surface u u u u u u u<br />

Type 1 — Indoor, Flush u u u u u u u<br />

Type 3R — Outdoor-Rainproof u u u u u u u<br />

Type 5, 12 — Lint, Fine Dust, Oils, Coolants — — — — — — —<br />

BQ1B020 BQ1B020H HB1B020<br />

For inches / millimeters conversion, see Application Data section.<br />

CQD breakers are rated 14,000 KAIC at 480/277V.<br />

Type CQD6—CSA only.<br />

3-pole only.<br />

d Applicable for 15-30A breakers only.<br />

7-8<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Molded Case Circuit Breakers<br />

Reference Guide<br />

Revised on 11/30/19<br />

Selection/Application<br />

Thermal-Magnetic Trip Breakers<br />

General Purpose Breakers<br />

CQD NGG HGG LGG<br />

Page 7-42 7-43 7-43 7-43<br />

Poles 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3<br />

1-Pole 15–100 15–125 15–125 15–125<br />

Amperes, Continuous<br />

2-Pole 15–100 15–125 15–125 15–125<br />

3-Pole 15–100 15-125 15–125 15–125<br />

1-Pole 277 347 347 347<br />

Volts (50/60 Hertz)<br />

2-Pole 480/277 600/347 600/347 600/347<br />

3-Pole 480/277 600/347 600/347 600/347<br />

120V 65,000 65,000 65,000 65,000<br />

UL<br />

240V 65,000 65,000 65,000 65,000<br />

480V 14,000 25,000 35,000 65,000<br />

600/347V 10,000 b 14,000 14,000 14,000<br />

AC<br />

Icu 18,000<br />

1-Pole<br />

25,000 — —<br />

220/<br />

Ics 9,000 d 12,500 — —<br />

240V<br />

Ratings<br />

DC<br />

Dimensions<br />

in inches<br />

Overcurrent<br />

Devices<br />

Accessories and<br />

Modifications<br />

Individual<br />

Enclosures<br />

Interrupt Rating Symmetrical RMS Amperes<br />

IEC<br />

947-2<br />

50/<br />

60Hz<br />

380/<br />

415V<br />

500V<br />

2,3-<br />

Pole<br />

1-Pole<br />

2,3-<br />

Pole<br />

1-Pole<br />

2,3-<br />

Pole<br />

Icu 65,000 d 65,000 — —<br />

Ics 32,500 d 32,500 — —<br />

Icu — — — —<br />

Ics — — — —<br />

Icu 18,000 d 25,000 — —<br />

Ics 9,000 d 12,500 — —<br />

Icu — — — —<br />

Ics — — — —<br />

Icu — — — —<br />

Ics — — — —<br />

Volts — 2-Pole 125/250 125/250 125/250 125/250<br />

Interrupting Rating — DC Amperes 14,000 14,000 14,000 14,000<br />

15–50A 4.50 5.40 5.40 5.40<br />

Height<br />

55–125A 4.50 5.40 5.40 5.40<br />

60–225A — — — —<br />

1-Pole 1.00 1.00 1.00 1.00<br />

Width<br />

2-Pole 2.00 2.00 2.00 2.00<br />

3-Pole 3.00 3.00 3.00 3.00<br />

Depth 2.87 2.90 2.90 2.90<br />

Thermal and Fixed Magnetic Trip u u u u<br />

Molded Case Switch — — — —<br />

Undervoltage Trip — — — —<br />

Shunt Trip u u u u<br />

Auxiliary Switch u u u u<br />

Alarm Switch u u u u<br />

Mechanical Interlock — — — —<br />

Fungus Proofing (ref. page 7-156) u u u u<br />

Type 1 — Indoor Surface — u u u<br />

Type 1 — Indoor, Flush — u u u<br />

Type 3R — Outdoor-Rainproof — u u u<br />

Type 5, 12 — Lint, Fine Dust, Oils, Coolants — — u u<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

CQD120<br />

LGG2B020L<br />

For inches / millimeters conversion, see Application Data section.<br />

CQD breakers are rated 14,000 KAIC at 480/277V.<br />

Type CQD6—CSA only.<br />

3-pole only.<br />

d Applicable for 15-30A breakers only.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-9


Molded Case Circuit Breakers<br />

3VA UL Breakers<br />

Revised on 09/30/20<br />

Reference Guide<br />

Type 3VA51 3VA51 3VA52 3VA53 3VA54 3VA55<br />

Page 7-48 7-48, 7-49, 7-50 7-56, 7-57, 7-58 7-64, 7-65 7-69 7-73<br />

Number of Poles 1 2, 3, 4 2 in 3-pole, 3, 4 2 in 3-pole, 3, 4 2 in 3-pole, 3, 4 3, 4<br />

3VA5 molded case circuit breakers<br />

Size 125 A 125 A 250 A 400 A 600 A 800 A<br />

Rated current I n A 15 … 125 15 … 125 100 … 250 200 … 400 400 … 600 600 … 800<br />

Frequency Hz 0 … 400 0 … 400 0 … 400 0 … 400 0 … 400 0 … 400<br />

Electrical characteristics according to UL489<br />

Rated operational voltage<br />

V 347 600 600 600 600 600<br />

50/60 Hz AC<br />

Electrical characteristics according to IEC 60947-2<br />

Rated operational voltage<br />

U e 50/60 Hz AC<br />

V 415 690 690 690 690 690<br />

Rated insulation voltage U i V 500 800 800 800 800 800<br />

Rated impulse withstand<br />

voltage U imp<br />

kV 8 8 8 8 8 8<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Short-circuit breaking capacity<br />

according to UL 489<br />

UL Breaker Type<br />

S<br />

SEAS<br />

M<br />

MEAS<br />

H<br />

HEAS<br />

S<br />

SEAS<br />

M<br />

MEAS<br />

H<br />

HEAS<br />

M<br />

MFAS<br />

H<br />

HFAS<br />

C<br />

CFAS<br />

M H<br />

MJAS HJAS<br />

120 V AC / 50/60 Hz kA 65 85 150 — — — — — — — — — — — — — — —<br />

240 V AC / 50/60 Hz kA — — — 65 85 100 85 100 200 85 100 200 85 100 200 85 100 200<br />

277 V AC / 50/60 Hz kA 25 35 50 — — — — — — — — — — — — — — —<br />

347 V AC / 50/60 Hz kA 14 18 18 — — — — — — — — — — — — — — —<br />

480 Y/277 V AC / 50/60 Hz kA — — — 25 35 65 35 65 100 35 65 100 35 65 100 35 65 100<br />

480 V AC / 50/60 Hz kA — — — 25 35 65 35 65 100 35 65 100 35 65 100 35 65 100<br />

600 Y/347 V AC / 50/60 Hz kA — — — 14 18 25 18 25 35 18 25 35 18 25 35 18 25 50<br />

600 V AC / 50/60 Hz kA — — — — — — 18 25 35 18 25 35 18 25 35 18 25 50<br />

125 V DC kA 14 25 30 — — — — — — — — — — — — — — —<br />

250 V DC kA — — — 50 85 100 50 85 100 50 85 100 50 85 100 50 85 100<br />

500 V DC kA — — — 50 85 100 50 85 100 50 85 100 50 85 100 50 85 100<br />

600 V DC (3-pole only) kA — — — — — — 50 85 100 50 85 100 50 85 100 50 85 100<br />

750 V DC (4-pole only) kA — — — — — — 50 85 100 50 85 100 50 85 100 50 85 100<br />

1000 V DC (4-pole only) kA — — — — — — 50 85 100 6 6 10 6 6 10 18 25 50<br />

Short-circuit breaking capacity<br />

according to IEC 60947-2<br />

S M H S M H M H C M H C M H C M H C<br />

Rated ultimate short-circuit breaking capacity I cu<br />

Rated service short-circuit breaking capacity I cs<br />

rms value, according to IEC 60947-2<br />

240 V AC / 50/60 Hz kA 25/25 36/36 55/55 55/55 85/85 150/150 85/85 100/100 200/200 85/85 100/100 200/200 85/85 100/100 200/200 85 100 200<br />

415 V AC / 50/60 Hz kA 5/5 5/5 5/5 36/36 55/55 70/70 55/55 70/70 110/110 55/55 70/70 110/110 55/55 70/70 110/110 55 70 110<br />

690 V AC / 50/60 Hz kA — — — 5/5 7/5 10/5 7/7 10/10 10/10 7/7 10/10 10/10 7/7 10/10 10/10 25 35 35<br />

125 V DC kA 14 25 30 — — — — — — — — — — — — — — —<br />

250 V DC kA — — — 50 85 100 50 85 100 50 85 100 50 85 100 50 85 100<br />

500 V DC kA — — — 50 85 100 50 85 100 50 85 100 50 85 100 50 85 100<br />

750 V DC (3-pole only) kA — — — — — — 50 85 100 50 85 100 50 85 100 50 85 100<br />

— Not available<br />

C<br />

CJAS<br />

M<br />

MLAS<br />

H<br />

HLAS<br />

C<br />

CLAS<br />

M<br />

MMAS<br />

H<br />

HMAS<br />

C<br />

CMAS<br />

Applicable Standards:<br />

n UL489 - Molded Case Circuit Breakers<br />

n UL486A - Wire connectors and solderless lugs for<br />

use with copper<br />

n UL486B- Wire connectors and solderless lugs for<br />

use with aluminum wire<br />

n CSA-22.2 No. 5-13 - Molded Case Circuit Breakers,<br />

Molded case switches and circuit breaker enclosures<br />

n EN 60947-1 AMD 2 - Molded case circuit breakers<br />

n EN 60947-2 AMD 2 2013<br />

n EN 50581 2012 - RoHS compliant<br />

7-10<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Molded Case Circuit Breakers<br />

3VA UL Breakers<br />

Revised on 06/30/20<br />

Reference Guide<br />

3VA61 3VA62 3VA63 3VA64 3VA65 3VA66<br />

7-52, 7-53 7-60, 7-61 7-66, 7-67 7-70, 7-71 7-74, 7-75 7-77, 7-78<br />

3, 4 3, 4 3, 4 3, 4 3, 4 3, 4<br />

150 A 250 A 400 A 600 A 800A 1000A<br />

15 … 125 15 … 125 100 … 250 200 … 400 600-800 1000<br />

0 … 400 0 … 400 0 … 400 0 … 400 50-60 50-60<br />

600 600 600 600 600 600<br />

690 690 690 690 690 690<br />

800 800 800 800 800 800<br />

8 8 8 8 8 8<br />

M H<br />

MDAE HDAE<br />

C<br />

CDAE<br />

L<br />

LDAE<br />

E<br />

EDAE<br />

M H<br />

MFAE HFAE<br />

C<br />

CFAE<br />

H E M H<br />

MFAE EFAE MJAE HJAE<br />

C<br />

CJAE<br />

L<br />

LJAE<br />

E<br />

EJAE<br />

M H<br />

MLAE HLAE<br />

C<br />

CLAE<br />

L<br />

LLAE<br />

E<br />

ELAE<br />

M<br />

MMAE<br />

H<br />

HMAE<br />

C<br />

CMAE<br />

M H<br />

MMNAE HMNAE<br />

— — — — — — — — — — — — — — — — — — — — — — — — — —<br />

100 100 200 200 — 100 100 200 200 — 100 100 200 200 — 100 100 200 200 — 100 150 200 100 150 200<br />

— — — — — — — — — — — — — — — — — — — — — — — — — —<br />

— — — — — — — — — — — — — — — — — — — — — — — — — —<br />

35 65 100 150 200 35 65 100 150 200 35 65 100 150 200 35 65 100 150 200 35 65 100 35 65 100<br />

35 65 100 150 200 35 65 100 150 200 35 65 100 150 200 35 65 100 150 200 35 65 100 35 65 100<br />

18 22 35 50 100 18 22 35 50 100 18 22 35 50 100 18 22 35 50 100 25 35 50 25 35 50<br />

18 22 35 50 100 18 22 35 50 100 18 22 35 50 100 18 22 35 50 100 25 35 50 25 35 50<br />

— — — — — — — — — — — — — — — — — — — — — — — — — —<br />

— — — — — — — — — — — — — — — — — — — — — — — — — —<br />

— — — — — — — — — — — — — — — — — — — — — — — — — —<br />

— — — — — — — — — — — — — — — — — — — — — — — — — —<br />

— — — — — — — — — — — — — — — — — — — — — — — — — —<br />

— — — — — — — — — — — — — — — — — — — — — — — — — —<br />

M H C L E M H C L E M H C L E M H C L E M H C M H C<br />

C<br />

CMNAE<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

— — — — — — — — — — — — — — — — — — — — 85 110 200 85 110 200<br />

55/55 85/85 110/110 150/150 200 55/55 85/85 110/110 150/150 200 55/55 85/85 110/110 150/150 200 55/55 85/85 110/110 150/150 200 55 85 110 55 85 110<br />

— — — — 3 — — — — 3 — — — — 3 — — — — 3 25 35 35 25 35 35<br />

— — — — — — — — — — — — — — — — — — — — — — — — — —<br />

— — — — — — — — — — — — — — — — — — — — — — — — — —<br />

— — — — — — — — — — — — — — — — — — — — — — — — — —<br />

— — — — — — — — — — — — — — — — — — — — — — — — — —<br />

UL Type Structure Position 1 Position 2 Position 3 Position 4<br />

KAIC @ 480V Frame Family Trip System / Special Application<br />

S = 25=low<br />

M = 35=med low<br />

H = 65=med<br />

C = 100=med high<br />

L = 150=high<br />

E = 200=extra high<br />

E = 125A max<br />

D = 150A max<br />

F = 250A max<br />

J = 400A max<br />

L = 600A max<br />

M = 800A max<br />

MN = 1000A max<br />

A = 3VA<br />

S = Standard TMTU or MCS (Molded Case Switch)<br />

E = High End ETU<br />

B = Panelboard TMTU (Bolt-on)<br />

M = TMTU 50°C/NAVAL (UL 489 SB)<br />

P = TMTU MCP (Motor Circuit Protector)<br />

R = ETU MCP (Motor Circuit Protector)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-11


Molded Case Circuit Breakers<br />

Reference Guide<br />

Revised on 10/31/18<br />

Selection/Application<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Thermal-Magnetic Trip Breakers<br />

General Purpose Breakers<br />

ED2 ED4 ED6 HED4 HHED6 CED6<br />

FD6A,<br />

FXD6A<br />

HFD6,<br />

HFXD6<br />

HHFD6,<br />

HHFXD6 CFD6<br />

Page 7-111 7-111 7-111 7-112 7-112 7-112 7-114 7-115 7-115 7-115<br />

Poles 1, 2, 3 1, 2, 3 1 d , 2, 3 1, 2, 3 3 2, 3 2, 3 2, 3 2, 3 3<br />

Amperes, Continuous 15–100 15–125 15–125 15–125 15–50 15–125 70 –250 70-250 70-250 70–250<br />

1-Pole 120 277 347 277 — — — — — —<br />

Volts 50/60HZ<br />

2-Pole 240 480 600 480 600 600 600 600 600 600<br />

3-Pole 240 480 600 480 600 600 600 600 600 600<br />

Ratings<br />

AC<br />

DC<br />

Dimensions<br />

in inches<br />

Overcurrent<br />

Devices<br />

Accessories<br />

and<br />

Modifications<br />

Individual<br />

Enclosures<br />

Interrupt Rating<br />

Symmetrical RMS Amperes<br />

UL<br />

IEC<br />

947-2<br />

50/<br />

60HZ<br />

120V 10,000 — — 100,000 — — — — — —<br />

240V 10,000 65,000 65,000 100,000 e 100,000 200,000 65,000 100,000 200,000 200,000<br />

277V — 22,000 a — 65,000 b — — — — — —<br />

347V — — 30,000 — — — — — — —<br />

480V — 18,000 25,000 142,000 65,000 200,000 35,000 65,000 100,000 200,000<br />

600V — — 18,000 — 18,000 100,000 22,000 25,000 25,000 100,000<br />

220/240V Icu — 65,000h — — — 65,000 100,000 — —<br />

Ics — — 17,000 h — — — 33,000 50,000 — —<br />

380/415V Icu — 35,000h — — — 35,000 65,000 — —<br />

Ics — — 9,000 h — — — 18,000 33,000 — —<br />

500V<br />

Icu — — 18,000 h — — — — — — —<br />

Ics — — 5,000 h — — — — — — —<br />

2-Pole, 250V DC Interrupting Ratings 5,000 30,000 30,000 30,000 — 30,000 30,000 30,000 — 50,000<br />

3-Pole, 500V DC Interrupting Ratings c — — 18,000 — — 50,000 18,000 25,000 — 50,000<br />

Height 6.34 6.34 6.34 6.34 6.58 9.26 9.50 9.50 14.12 14.12<br />

1-Pole 1.00 1.00 1.00 1.00 — — — — — —<br />

Width<br />

2-Pole 2.00 2.00 2.00 2.00 2.00 2.00 4.50 4.50 4.50 4.50<br />

3-Pole 3.00 3.00 3.00 3.00 3.00 3.00 4.50 4.50 4.50 4.50<br />

4-Pole — — — — — — — — — —<br />

Depth 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00<br />

Thermal and Fixed Magnetic Trip u u u u u u — — — —<br />

Thermal and Adjustable Magnetic Trip — — — — — — u u u u<br />

Adjustable Magnetic Trip only — — u — — u u — — u<br />

Motor Circuit Protector u — — u<br />

Molded Case Switch u u u — — u u — — u<br />

Undervoltage Trip u u u u u u u u u u<br />

Shunt Trip u u u u u u u u u u<br />

Auxiliary Switch u u u u u u u u u u<br />

Alarm Switch u u u u u u u u u u<br />

Mechanical Interlock — — — — — — u u u u<br />

Rear Connection Studs u u u u u u u u u u<br />

Electric Motor Operator u u u u u u u u u u<br />

Plug-In Mounting Assembly (3 Pole Only) u u u u u u u u u u<br />

Fungus Proofing (ref. page 7-156) u u u u u u u u u u<br />

Type 1 — Indoor Surface u u u u u u u u u u<br />

Type 1 — Indoor, Flush u u u u u u — u — u<br />

Type 3R — Outdoor-Rainproof u u u u u u u u u u<br />

Type 7 — Flammable Gas Atmosphere u u u u u — u u u —<br />

Type 9 — Combustion Dusttight u u u u u — u u u —<br />

Type 5, 12 — Lint, Fine Dust, Oils, Coolants u u u u u u u u u u<br />

Type 12K — Semi-Dusttight u u u u u u u u u u<br />

For inches / millimeters conversion, see Application Data section.<br />

a 1-pole only.<br />

b 35-100A: 25,000 AIR at 277V AC/15-30A:<br />

65,000 AIR at 277V AC.<br />

c For DC UPS system application.<br />

d Single pole ED6 (15–30A) 30kA, (35–100A) 18 kA. CSA Only.<br />

e Single pole HED4, 15-30A: 65,000 AIR at 240V AC; single<br />

pole HED4, 35-100A: 25,000 AIR at 240V AC.<br />

f HGG and LGG breakers are rated at 600/347V.<br />

g ED6, 2-pole available 20-30 amps only.<br />

h Rating applicable only to 3-pole breakers<br />

ED62B020 HED41B040 HHED63B020<br />

7-12<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Molded Case Circuit Breakers<br />

Reference Guide<br />

Revised on 10/31/18<br />

Selection/Application<br />

Thermal-Magnetic Trip Breakers<br />

General Purpose Breakers<br />

JXD2-A<br />

JD6-A,<br />

JXD6-A<br />

HJD6-A,<br />

HJXD6-A<br />

HHJD6-A,<br />

HHJXD6-A CJD6-A<br />

LD6,<br />

LXD6<br />

HLD6,<br />

HLXD6<br />

HHLD6,<br />

HHLXD6 CLD6-A<br />

Page 7-117 7-117 7-118 7-118 7-118 7-121 7-122 7-122 7-122<br />

Poles 2, 3 2, 3 2, 3 2, 3 3 2, 3 2, 3 2, 3 3<br />

Amperes, Continuous 200-400 200-400 200-400 200-400 200-400 250-600 250-600 250-600 450-600<br />

Volts 50/60HZ<br />

2-Pole<br />

3-Pole<br />

240 600 600 600 600 600 600 600 600<br />

Ratings<br />

AC<br />

DC<br />

Dimensions in<br />

inches<br />

Overcurrent<br />

Devices<br />

Accessories &<br />

Modifications<br />

Individual<br />

Enclosures<br />

Interrupt Rating<br />

Symmetrical RMS Amperes<br />

UL<br />

220/<br />

240V<br />

IEC 947-2 380/<br />

50/60HZ a 415V<br />

240V 65,000 65,000 100,000 200,000 200,000 65,000 100,000 200,000 200,000<br />

480V — 35,000 65,000 100,000 150,000 35,000 65,000 100,000 150,000<br />

600V — 25,000 35,000 50,000 100,000 25,000 35,000 50, 000 100,000<br />

Icu — 65,000 100,000 — — 65,000 100,000 — —<br />

Ics — 33,000 50,000 — — 33,000 50,000 — —<br />

Icu — 40,000 65,000 — — 40,000 65,000 — —<br />

Ics — 20,000 33,000 — — 20,000 33,000 — —<br />

500V Icu — — — — — — — — —<br />

Ics — — — — — — — — —<br />

2-Pole 250V DC Interrupting Ratings 30,000 30,000 30,000 — — 30,000 30,000 — —<br />

3-Pole, 500V DC Interrupting Ratings b — 25,000 35,000 — 50,000 35,000 — — 50, 000<br />

Height 11.00 11.00 11.00 11.00 17.86 11.00 11.00 11.00 17.86<br />

Width 2, 3-Pole 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50<br />

Depth 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00<br />

Thermal and Fixed Magnetic Trip — — — — — — — — —<br />

Thermal and Adjustable Magnetic Trip u u u u u u u u u<br />

Adjustable Magnetic Trip Only<br />

Motor Circuit Protector<br />

— u — — u u — — u<br />

Molded Case Switch u u u — u u u — u<br />

Undervoltage Trip u u u u u u u u u<br />

Shunt Trip u u u u u u u u u<br />

Auxiliary Switch u u u u u u u u u<br />

Alarm Switch u u u u u u u u u<br />

Mechanical Interlock u u u u u u u u u<br />

Rear Connection Studs u u u u u u u u u<br />

Electric Motor Operator u u u u u u u u u<br />

Plug-In Mounting Assembly u u u u u u u u u<br />

Fungus Proofing (ref. page 7-156) — u u u u u u u u<br />

Type 1 — Indoor Surface u u u u u u u u u<br />

Type 1 — Indoor, Flush — — — — — — — — —<br />

Type 3R — Outdoor-Rainproof u u u u u u u u u<br />

Type 7 — Flammable Gas Atmosphere u u u u — u u u —<br />

Type 9 — Combustion Dusttight u u u u — u u u —<br />

Type 5, 12 — Lint, Fine Dust, Oils, Coolants u u u u u u u u u<br />

Type 12K — Semi-Dusttight u u u u u u u u u<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

For inches / millimeters conversion, see Application Data section.<br />

a Only applicable to non-interchangeable trip unit types:<br />

JXD6-A, HJXD6-A, LXD6 and HLXD6<br />

b For DC UPS application.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-13


Molded Case Circuit Breakers<br />

Reference Guide<br />

Revised on 10/31/18<br />

Selection/Application<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Thermal-Magnetic Trip Breakers<br />

General Purpose Breakers<br />

LMD6,<br />

LMXD6<br />

HLMD6,<br />

HLMXD6<br />

MD6,<br />

MXD6<br />

HMD6,<br />

HMXD6 CMD6<br />

ND6,<br />

NXD6<br />

HND6,<br />

HNXD6 CND6<br />

PD6, b<br />

PXD6 b<br />

HPD6, b<br />

HPXD6 b CPD6 b<br />

Page 7-125 7-126 7-128 7-129 7-129 7-132 7-133 7-133 7-136 7-136 7-136<br />

Poles 2, 3 2, 3 2, 3 2, 3 3 2, 3 2, 3 3 3 3 3<br />

Ratings<br />

AC<br />

DC<br />

Dimensions<br />

in inches<br />

Amperes, Continuous<br />

Volts 50/60 HZ<br />

Interrupt Rating<br />

Symmetrical RMS Amperes<br />

500-<br />

800<br />

500-<br />

800<br />

500-<br />

800<br />

500-<br />

800<br />

400-<br />

800<br />

2-Pole<br />

3-Pole<br />

600 600 600 600 600 600 600 600 600 600 600<br />

240V 65,000 100,000 65,000 100,000 200,000 65,000 100,000 200,000 65,000 100,000 200,000<br />

UL<br />

480V 50,000 65,000 50,000 65,000 100,0001 50,000 65,000 100,000 50,000 65,000 100,000<br />

600V 25,000 50,000 25,000 50,000 65,0001 25,000 50,000 65,000 25,000 50,000 65,000<br />

415V Ics — — 20,000 33,000 — 20,00011 33,000 — — — —<br />

220/ Icu — — 65,000 100,000 — 65,000 100,000 — — — —<br />

240V Ics — — 33,000 50,000 — 33,0001 50,000 — — — —<br />

IEC 947-2<br />

50/60HZ c 380/ Icu — — 40,000 65,000 — 40,0001 65,000 — — — —<br />

500V<br />

Icu — — — — —1 — — — — — —<br />

Ics — — — — — —1 — — — — —<br />

2-Pole 250V DC Interrupting Ratings 30,000 30,000 30,000 30,000 30,0001 30,0001 30,000 30,000 30,000 30,000 30,000<br />

3-Pole, 500V DC Interrupting Ratings a 25,000 50,000 25,000 50,000 50,000 25,00011 50,000 50,000 25,000 50,000 50,000<br />

Circuit breakers require<br />

Connect-all mounting<br />

block. Dims shown are<br />

for circuit breaker only.<br />

Height 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.0 16.00 16.00<br />

Width 7.50 7.50 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00<br />

Depth 4.59 4.59 6.19 6.19 6.19 6.191 6.19 6.19 6.19 6.19 6.19<br />

Overcurrent Thermal and Adjustable Magnetic Trip u u u u u u u u u u u<br />

Devices Adjustable Magnetic Trip Only<br />

Motor Circuit Protector<br />

u — u — u — — — — —<br />

—<br />

Molded Case Switch u — u u — —<br />

Accessories Undervoltage Trip u — u — u u u u u u u<br />

and Shunt Trip u u u u u u u u u u u<br />

Modifications<br />

Auxiliary Switch u u u u u u u u u u u<br />

Alarm Switch u u u u u u u u u u u<br />

Mechanical Interlock u u u u u u u u u u u<br />

Rear Connections Studs u u u u u u u u — — —<br />

Electric Motor Operator u u u u u u u u u u u<br />

Plug-in Mounting Assembly u u u u u u u u — — —<br />

Fungus Proofing (ref. page 7-156) — — u u u u u u u u u<br />

Mounting Block (required) — — — — — — — — u u u<br />

Individual<br />

Enclosures<br />

Type 1 — Indoor Surface u u u u u u u u u u u<br />

Type 1 — Indoor, Flush — — — — — — — — — — —<br />

Type 3R — Outdoor-Rainproof u u u u u u u u — — —<br />

Type 7 — Flammable Gas Atmosphere — — — — — — — — — — —<br />

Type 9 — Combustion Dusttight — — — — — — — — — — —<br />

Type 5, 12 — Lint, Fine Dust, Oils,<br />

Coolants<br />

— — — — — — — — — — —<br />

Type 12K — Semi-Dusttight u u u u u u u u — — —<br />

800-<br />

1200<br />

800-<br />

1200<br />

800-<br />

1200<br />

1200-<br />

1600<br />

1200-<br />

1600<br />

1200-<br />

1600<br />

For inches / millimeters conversion, see Application Data section.<br />

a For DC UPS application.<br />

b Requires Connect-all mounting assembly. Dimensions<br />

shown are for circuit breaker only.<br />

c Only applicable to non-interchangeable trip unit types:<br />

NXD6, HNXD6, MXD6 and HMXD6<br />

7-14<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Molded Case Circuit Breakers<br />

Reference Guide<br />

Revised on 05/31/18<br />

Selection<br />

Thermal-Magnetic Trip Breakers<br />

& Electronic Trip Breakers<br />

General Purpose<br />

Breakers<br />

Solid State Trip Circuit Breakers<br />

RD6, a HRD6, a<br />

RXD6 a HRXD6 a SJD6 SHJD6 SCJD6 SLD6 SHLD6 SCLD6<br />

Page 7-139 7-139 7-119 7-119 7-119 7-123 7-123 7-123<br />

Poles 3 3 3 3 3 3 3 3<br />

Amperes, Continuous 1600-2000 1600-2000 200-400 200-400 200-400 300-600 300-600 300-600<br />

Volts 50/60 HZ 3-Pole 600 600 600 600 600 600 600 600<br />

240V 65,000 100,000 65,000 100,000 200,000 65,000 100,000 200,000<br />

UL 480V 50,000 65,000 35,000 65,000 150,000 35,000 65,000 150,000<br />

600V 25,000 50,000 25,000 35,000 100,000 25,000 35,000 100,000<br />

AC<br />

Ratings<br />

Interrupt Rating<br />

Symmetrical RMS<br />

220/240V Icu — — — — — — — —<br />

Ics — — — — — — — —<br />

Amperes<br />

IEC60947-2 Icu — — — — — — — —<br />

380/415V<br />

50/60HZ Ics — — — — — — — —<br />

500V<br />

Icu — — — — — — — —<br />

Ics — — — — — — — —<br />

2-Pole 250V DC Interrupting Ratings 30,000 30,000 — — — — — —<br />

DC<br />

3-Pole, 500V DC Interrupting Ratings a 25,000 50,000 — — — — — —<br />

Height 16.00 16.00 11.00 11.00 17.86 11.0 11.00 17.86<br />

Dimensions in<br />

Width 3-Pole 9.00 9.00 7.50 7.50 7.50 7.50 7.50 7.50<br />

inches<br />

Depth 6.19 6.19 4.00 4.00 4.00 4.00 4.00 4.00<br />

Solid State Trip — — u u u u u u<br />

Optional DAS / Maintenance Mode — — u u u u u u<br />

Overcurrent Thermal and Adjustable Magnetic Trip u u — — — — — —<br />

Devices Adjustable Magnetic Trip Only — — — — — — — —<br />

Motor Circuit Protector<br />

Molded Case Switch u — — — — — — —<br />

Undervoltage Trip u u u u u u u u<br />

Shunt Trip u u u u u u u u<br />

Auxiliary Switch u u u u u u u u<br />

Accessories & Alarm Switch u u u u u u u u<br />

Modifications Mechanical Interlock u u u u u u u u<br />

Rear Connections Studs — — u u u u u u<br />

Electric Motor Operator u u u u u u u u<br />

Plug-In Mounting Assembly — — u u u u u u<br />

Fungus Proofing (ref. page 7-156) u u u u u u u u<br />

Mounting Block (required) u u — — — — — —<br />

Type 1 — Indoor Surface u u u u u u u u<br />

Type 1 — Indoor, Flush — — — — — — — —<br />

Type 3R — Outdoor-Rainproof — — u u — u u —<br />

Individual<br />

Enclosures<br />

Type 7 — Flammable Gas Atmosphere — — u u — u u —<br />

Type 9 — Combustion Dusttight — — u u — u u —<br />

Type 5, 12 — Lint, Fine Dust, Oils, Coolants — — u u u u u u<br />

Type 12K — Semi-Dusttight — — u u u u u u<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

For inches / millimeters conversion, see Application Data section.<br />

a Requires Connect-all mounting assembly. Dimensions<br />

shown are for circuit breaker only.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-15


Molded Case Circuit Breakers<br />

Reference Guide<br />

Revised on 05/31/18<br />

Selection<br />

7<br />

Electronic Trip Breakers<br />

Solid State Trip Circuit Breakers<br />

SMD6 SHMD6 SCMD6 SND6 SHND6 SCND6 SPD6 a SHPD6 a<br />

Page 7-130 7-130 7-130 7-134 7-134 7-134 7-137 7-137<br />

Poles 3 3 3 3 3 3 3 3<br />

Amperes, Continuous 600- 600- 600- 800- 800- 800- 1200- 1200-<br />

- 800 800 800 1200 1200 1200 1600 1600<br />

Volts 50/60HZ 3-Pole 600 600 600 600 600 600 600 600<br />

240V 65,000 100,000 200,000 65,000 100,000 200,000 65,000 100,000<br />

Ratings AC Interrupt<br />

UL 480V 50,000 65,000 100,000 50,000 65,000 100,000 50,000 65,000<br />

Rating 600V 25,000 50,000 65,000 25,000 50,000 65,000 25,000 50,000<br />

Symmetrical<br />

380/415V Icu — — — — — — — —<br />

RMS<br />

IEC60947-2 Ics — — — — — — — —<br />

Amperes 50/60HZ<br />

Icu — — — — — — — —<br />

690V<br />

Ics — — — — — — — —<br />

Height 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00<br />

Dimensions in Width 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00<br />

inches<br />

Depth 6.19 6.19 6.19 6.19 6.19 6.19 6.19 6.19<br />

Overcurrent Solid State Trip u u u u u u u u<br />

Devices Optional DAS / Maintenance Mode u u u u u u u u<br />

Undervoltage Trip u u u u u u u u<br />

Shunt Trip u u u u u u u u<br />

Auxiliary Switch u u u u u u u u<br />

Alarm Switch u u u u u u u u<br />

Accessories & Mechanical Interlock u u u u u u u u<br />

Modifications<br />

Rear Connection Studs u u u u u u — —<br />

Electric Motor Operator u u u u u u u u<br />

Plug-In Mounting Assembly u u u u u u — —<br />

Fungus Proofing (ref. page 7-156) u u u u u u u u<br />

Type 1 — Indoor Surface u u u u u u u u<br />

Type 1 — Indoor, Flush — — — — — — — —<br />

Type 3R — Outdoor-Rainproof u u u u u u — —<br />

Individual<br />

Enclosures<br />

Type 7 — Flammable Gas Atmosphere — — — — — — — —<br />

Type 9 — Combustion Dusttight — — — — — — — —<br />

Type 5, 12 — Lint, Fine Dust, Oils, Coolants u u u u u u — —<br />

Type 12K — Semi-Dusttight u u u u u u — —<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

For inches / millimeters conversion, see Application Data section.<br />

a Requires connect-all mounting block assembly. Dimensions<br />

shown are for circuit breaker.<br />

7-16<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Molded Case Circuit Breakers<br />

Reference Guide<br />

Revised on 10/31/18<br />

Selection/Application<br />

Page 7-175 7-179 7-183<br />

Breaker Frame Family DG FG JG<br />

Continuous Amps 30–150A 40–250A 70–400A<br />

Poles 2, 3 2, 3 2, 3<br />

Max. Volts AC 600Y/347V 600Y/347V 600V<br />

Breaker Type NDGA HDGA LDGA NFGA HFGA LFGA NJGA HJGA LJGA<br />

Interrupting Class N H L N H L N H L<br />

240Vac 65 100 200 65 100 200 65 100 200<br />

Interrupting UL 480Vac 35 65 100 35 65 100 35 65 100<br />

Rating RMS<br />

600Vac 18 18 18 18 18 18 25 25 25<br />

Symmetrical<br />

Ratings Amperes<br />

220/240Vac 65/65 100/75 200/150 65/65 100/75 200/150 65/65 100/75 200/150<br />

AC 50/60Hz l CU /l CS 380/415Vac 40/40 70/70 100/75 40/40 70/70 100/75 45/45 70/70 100/75<br />

690Vac 12/6 12/6 12/6 12/6 12/6 12/6 12/6 15/8 15/8<br />

DC<br />

250Vdc (2-Pole) 30 30 30 30 30 30 30 30 30<br />

Ratings (UL) b 600Vdc (3-Pole) — — — — 42 — — 65 —<br />

Interrupting<br />

500Vdc (3-Pole) 18 18 18 18 18 30 25 35 35<br />

Dimensions<br />

in Inches<br />

Trip Unit<br />

Information<br />

Specific<br />

Application<br />

Breakers<br />

Accessories &<br />

Modifications<br />

1-Pole — —<br />

2-Pole 6.9H x 4.1W x 3.4D 11H x 5.5W x 4.2D<br />

3-Pole 6.9H x 4.1W x 3.4D 11H x 5.5W x 4.2D<br />

4-Pole — —<br />

Thermal-Magnetic u u u<br />

Electronic u u u<br />

Electronic with LCD u u u<br />

Interchangeable Trip Unit — — u<br />

Reverse Feed (w/Non-Interchangeable Trip) u u u<br />

Communications Capability u u u<br />

Molded Case Switch u u u<br />

Motor Circuit Protector u u u<br />

100% Rated u u<br />

50°C Calibrated <br />

Auxiliary Switch u u u<br />

Alarm Switch u u u<br />

Shunt Trip u u u<br />

Undervoltage Release u u u<br />

Mechanical Interlocks u u u<br />

Electric Motor or Stored Energy Operator u u u<br />

Rear Connecting Studs u u u<br />

Plug-In Mounting Assy. w/Trip Interlock u u u<br />

Draw-Out Assembly u u u<br />

Handle Mechanism Options u u u<br />

Enclosures NEMA 3R – Outdoor, Rain Proof u u<br />

NEMA 4, 4X – Stainless Steel u u<br />

NEMA 1 – Indoor, Surface Mount u u<br />

NEMA 1 – Indoor, Flush Mount u u<br />

NEMA 7, 9 – Hazardous Locations<br />

NEMA 12 – Dust u u<br />

Terminal Shields u u u<br />

Distribution Lugs u u u<br />

Ground Sensor (Neutral Transformer) u u u<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

a 500Vdc nominal, 600Vdc max. for ungrounded DC UPS systems.<br />

b DC Interrupting Ratings are not applicable to electronic circuit breakers.<br />

Communications available via a COMPRO or COMMOD modules using Profibus or Modbus protocols.<br />

Consult Siemens for availability.<br />

“Non-metallic” NEMA 4X enclosure for NGG breakers.<br />

Special version, see page 7-204.<br />

GG are not VL family breakers and do not share common VL accessories.<br />

304 and 316 Stainless Steel<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-17


Molded Case Circuit Breakers<br />

Reference Guide<br />

Selection/Application<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Page 7-187 7-191 7-195 7-199<br />

Breaker Frame Family LG MG NG PG<br />

Continuous Amps 150–600A 200–800A 300–1200A 400–1600A<br />

Poles 2, 3 2, 3 2, 3 3<br />

Max. Volts AC 600V 600V 600V 600V<br />

Breaker Type NLGB HLGB LLGB NMG HMG LMG NNG HNG LNG NPG HPG LPG<br />

Ratings<br />

Dimensions<br />

in Inches<br />

Trip Unit<br />

Information<br />

Specific<br />

Application<br />

Breakers<br />

Accessories<br />

and<br />

Modifications<br />

Interrupting Class N H L N H L N H L N H L<br />

Interrupting<br />

Rating RMS<br />

Symmetrical<br />

Amperes<br />

AC 50/60Hz<br />

240Vac 65 100 200 65 100 200 65 100 200 65 100 200<br />

UL 480Vac 35 65 100 35 65 100 35 65 100 35 65 100<br />

600Vac 18 18 18 25 35 65 25 35 65 25 35 65<br />

220/240Vac 65/65 100/75 200/150 65/35 100/50 200/150 65/65 100/75 200/100 65/35 100/50 200/100<br />

l CU /<br />

380/415Vac 45/45 70/70 100/75 50/50 70/70 100/75 50/25 70/35 100/50 50/25 70/35 100/50<br />

l CS<br />

690Vac 12/6 15/8 15/8 20/10 30/15 35/17 20/10 30/15 35/17 20/10 30/15 35/15<br />

Ratings (UL) c 600Vdc (3-Pole) — 65 — — 65 — — 65 — — 65 —<br />

250Vdc (2-Pole) 30 30 30 22 25 42 22 25 42 22 25 42<br />

DC<br />

Interrupting<br />

500Vdc (3-Pole) 25 35 35 35 50 65 35 50 65 35 50 65<br />

2-Pole 11H x 5.5W x 4.2D 16H x 7.5W x 4.7D 16H x 9W x 6.2D —<br />

3-Pole 11H x 5.5W x 4.2D 16H x 7.5W x 4.7D 16H x 9W x 6.2D<br />

Thermal-Magnetic u u u u<br />

Electronic u u u u<br />

Electronic with LCD u u u u<br />

Interchangeable Trip Unit u u u u<br />

Reverse Feed (w/Non-Interchangeable Trip) u u u u<br />

Communications Capability a u u u u<br />

Molded Case Switch u u u u<br />

Motor Circuit Protector u u u<br />

100% Rated u u u u<br />

Auxiliary Switch u u u u<br />

Alarm Switch u u u u<br />

Shunt Trip u u u u<br />

Undervoltage Release u u u u<br />

Mechanical Interlocks u u u u<br />

Electric Motor or Stored Energy Operator u u u u<br />

Rear Connecting Studs u u u u<br />

Plug-In Mounting Assy. w/Trip Interlock<br />

u<br />

Draw-Out Assembly u u<br />

Handle Mechanism Options u u u u<br />

Terminal Shields u u u u<br />

Distribution Lugs<br />

Ground Sensor (Neutral Transformer) u u u u<br />

a Communications available via COMPRO or COMMOD modules using Profibus or Modbus protocol.<br />

b 500Vdc nominal, 600Vdc max. for ungrounded DC UPS systems.<br />

c DC Interrupting Ratings are not applicable to electronic circuit breakers.<br />

LG frame maximum 500A.<br />

Special version, see page 7-204.<br />

Special 600Vac 25kA version available, see page 7-188.<br />

7-18<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Circuit Breakers<br />

Arc-Fault and Ground-Fault Breakers<br />

Revised on 01/31/20<br />

Selection/Wiring Diagrams<br />

Arc-Fault Circuit Interrupters (AFCI)<br />

AFCI’s detect arcing faults (an unintentional arcing condition in a circuit) that standard<br />

circuit breakers are not designed to detect. The device is intended to mitigate<br />

the effects of arcing faults by functioning to de-energize the circuit when an arcfault<br />

is detected.<br />

Combination Type AFCI<br />

Detects all three possible types of arc faults: line-to-ground, line-to-neutral, and series.<br />

Breaker<br />

Type<br />

QAF2/QAFH2/HQAF2<br />

1-Pole 120V AC<br />

QAF/QAFH<br />

2-Pole 120/240V AC<br />

QAF2N<br />

Plug-on Neutral/1-Pole 120V AC<br />

QAF/QAFH<br />

Plug-on Neutral/2-Pole 120/240V AC<br />

Amp<br />

Rating<br />

15<br />

20<br />

15<br />

20<br />

QAF2/QPF/QE/QPF2 Accessories<br />

10,000 A IR<br />

Catalog No.<br />

QA115AFC <br />

QA120AFC <br />

Q215AFC <br />

Q220AFC <br />

22,000 A IR<br />

Catalog No.<br />

QA115AFCH <br />

QA120AFCH <br />

Q215AFCHn —<br />

Q220AFCHn —<br />

15 QA115AFCN — —<br />

20 QA120AFCN — —<br />

15 Q215AFCN — —<br />

20 Q220AFCN — —<br />

65,000 A IR<br />

Catalog No.<br />

QA115AFCHHn <br />

QA120AFCHHn <br />

Dual Function AFCI/GFCI<br />

The Dual Function Circuit Breaker combines Combination Type AFCI and 5mA GFCI<br />

protection in one device. The device includes the Self Test feature, making it the first in<br />

class in electrical safety for homeowners.<br />

QFGA2/QFGAH2/HQFGA2<br />

1-Pole 120V AC<br />

QFGA2N<br />

Plug-on Neutral/1-Pole 120V AC<br />

Description<br />

Padlocking Device 1-Pole<br />

Padlocking Device 2-Pole<br />

Handle Block<br />

15<br />

20<br />

Q115DF <br />

Q120DF <br />

Q115DFHn <br />

Q120DFH <br />

15 Q115DFN — —<br />

20 Q120DFN — —<br />

Ground-Fault Circuit Interrupters (GFCI)<br />

Catalog Number <br />

ECPLD1<br />

ECPLD2<br />

ECBX231M<br />

Q115DFHHn <br />

Q120DFHHn <br />

Provides Class A (5mA) ground fault protection. Intended for personnel protection.<br />

Includes Self Test as an added safety feature.<br />

Breaker Type<br />

QPF2/QPHF2/HQPF2<br />

1-Pole 120V AC<br />

QPF/QPHF<br />

2-Pole 120/240V AC<br />

QPF2N<br />

Plug-on Neutral/1-Pole 120V AC<br />

Amp<br />

Rating<br />

15<br />

20<br />

30<br />

15<br />

20<br />

30<br />

40<br />

50<br />

60<br />

10,000 A IR<br />

Catalog No.<br />

QF115A a<br />

QF120A a<br />

QF130A a<br />

QF215A<br />

QF220A<br />

QF230A<br />

QF240A<br />

QF250A<br />

QF260A<br />

22,000 A IR<br />

Catalog No.<br />

QF115AHn a<br />

QF120AHn a<br />

QF130AHn a<br />

QF215AHn<br />

QF220AHn<br />

QF230AHn<br />

QF240AHn<br />

QF250AHn<br />

QF260AHn<br />

15 QF115AN — —<br />

20 QF120AN — —<br />

30 QF130AN — —<br />

Ground Fault Equipment Protection (30mA)<br />

Provides protection of equipment from damaging line-to-ground faults currents.<br />

QE/QEH<br />

1-Pole 120V AC<br />

QE/QEH<br />

2-Pole 120/240V AC<br />

15<br />

20<br />

30<br />

15<br />

20<br />

30<br />

40<br />

50<br />

60<br />

QE115<br />

QE120<br />

QE130<br />

QE215<br />

QE220<br />

QE230<br />

QE240<br />

QE250<br />

QE260<br />

QE115Hn<br />

QE120Hn<br />

QE130Hn<br />

QE215Hn<br />

QE220Hn<br />

QE230Hn<br />

QE240Hn<br />

QE250Hn<br />

QE260Hn<br />

65,000 A IR<br />

Catalog No.<br />

QF115AHHn a<br />

QF120AHHn a<br />

QF130AHHn a<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

n Built to order. Allow 8 -10 weeks for delivery.<br />

a UL Listed as SWD (Switching Duty) Rated, suitable<br />

for 120V AC Fluorescent Lighting.<br />

1-Pole Combination<br />

Type AFCI<br />

1-Pole Dual<br />

Function AFCI/GFC<br />

1-Pole AFCI<br />

Plug-on Neutral<br />

1-Pole GFCI<br />

2-Pole Combination<br />

Type AFCI<br />

1-Pole Dual Function<br />

Plug-on Neutral<br />

2-Pole GFCI<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-19


Circuit Breakers<br />

Type QP with INSTA-WIRE<br />

Revised on 10/31/18<br />

Selection<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Continuous Current<br />

Rating @ 40° C<br />

Type QP Type QPH Type HQP<br />

10,000A IR 22,000A IR 65,000A IR<br />

Catalog Number Catalog Number Catalog Number<br />

1-Pole Plug-In (120/240V AC) e<br />

10 Q110 — —<br />

15 Q115c Q115H c Q115HHn c<br />

20 Q120c Q120H c Q120HHn c<br />

25 Q125 Q125Hn Q125HHn<br />

30 Q130 Q130H Q130HHn<br />

35 Q135n Q135Hn Q135HHn<br />

40 Q140 Q140H Q140HHn<br />

45 Q145n Q145Hn Q145HHn<br />

50 Q150 Q150H Q150HHn<br />

60 Q160 Q160Hn Q160HHn<br />

70 Q170 Q170Hn Q170HHn<br />

2-Pole Plug-In (Common-Trip 120/240V AC) <br />

10 Q210 — —<br />

15 Q215 Q215H Q215HH<br />

20 Q220 Q220H Q220HH<br />

25 Q225 Q225Hn Q225HHn<br />

30 Q230 Q230H Q230HH<br />

35 Q235 Q235Hn Q235HHn<br />

40 Q240 Q240H Q240HHn<br />

45 Q245 Q245Hn Q245HHn<br />

50 Q250 Q250H Q250HH<br />

60 Q260 Q260H Q260HH<br />

70 Q270 Q270H Q270HH<br />

80 Q280 Q280Hn Q280HHn<br />

90 Q290 Q290H Q290HHn<br />

100 Q2100 Q2100H Q2100HH<br />

110 Q2110 Q2110H Q2110HHn<br />

125 Q2125 Q2125H Q2125HH<br />

2-Pole Plug-In (Common-Trip 240V AC) <br />

15 Q215R — —<br />

20 Q220R — —<br />

30 Q230R — —<br />

40 Q240R — —<br />

50 Q250R — —<br />

3-Pole Plug-In (Common-Trip 240V AC) <br />

15 Q315 Q315H Q315HHn<br />

20 Q320 Q320H Q320HH<br />

25 Q325 Q325Hn Q325HHn<br />

30 Q330 Q330H Q330HH<br />

35 Q335 Q335Hn Q335HHn<br />

40 Q340 Q340H Q340HH<br />

45 Q345 Q345Hn Q345HHn<br />

50 Q350 Q350H Q350HH<br />

60 Q360 Q360H Q360HH<br />

70 Q370 Q370H Q370HHn<br />

80 Q380 Q380H Q380HHn<br />

90 Q390 Q390H Q390HHn<br />

100 Q3100 Q3100H Q3100HH<br />

Q120<br />

Q220<br />

Q320<br />

QP / QPH / HQP Internal Accessories<br />

Control Voltage AC Catalog Number Field/Factory Installed<br />

120V Shunt Trip add suffix …00S01n Factory<br />

24V Shunt Trip add suffix …00S07n Factory<br />

120V Auxiliary Switch add suffix …01n b Factory<br />

Modifications<br />

Description<br />

Catalog Number<br />

400 Hz Calibration add suffix …Y h<br />

Marine 50˚C Ambient<br />

Calibration<br />

add suffix …M<br />

Fungus Proofing add suffix …F<br />

For external<br />

accessories, please<br />

refer to page 7-158<br />

n Built to order. Allow 2-3 weeks for delivery.<br />

a UL Listed for use with 60/75° wire through 40 amps,<br />

UL listed for use with 75° wire only for 50 amps<br />

and above, HACR rated.<br />

b 1A and 1B contacts.<br />

c UL Listed for frequent switching applications (SWD).<br />

120V AC Fluorescent Lighting.<br />

d UL Listed for use on 3-phase grounded “B” systems —<br />

10,000 for this application.<br />

e Shipped 12 per sleeve.<br />

f Shipped 6 per sleeve.<br />

g Shipped 4 per sleeve.<br />

h UL Listed 5 KA IR.<br />

i Type QP1, UL listed for 16 AWG conductors and<br />

multiple wires.<br />

7-20<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Circuit Breakers<br />

Duplex, Triplex and Quadplex Plug-In Breakers<br />

Duplex Circuit Breakers<br />

Breaker Type<br />

QT<br />

1-Pole<br />

10K AIC<br />

120V AC<br />

Triplex Circuit Breakers<br />

Breaker<br />

Type<br />

QT<br />

2-Pole<br />

10K AIC<br />

120/240V AC<br />

Inner Poles<br />

Common Trip<br />

Ampere<br />

Rating Catalog Number Catalog Number<br />

15–15 Q1515 Q1515NC a<br />

15–20 Q1520 Q1520NC a<br />

20–20 Q2020 Q2020NC a<br />

20–30 Q2030 —<br />

30–15n Q3015 —<br />

30–20 Q3020 —<br />

30–30 Q3030 Q3030NC a<br />

SHIPPING: 12 per carton, (Wt. 4.8 lbs.)<br />

Ampere Rating<br />

Single Pole<br />

Common-Trip<br />

2-Pole<br />

Catalog<br />

Number<br />

15 15 Q21515CT<br />

15 20 Q21520CT<br />

15 25 Q21525CTn<br />

15 30 Q21530CT<br />

15 35 Q21535CTn<br />

15 40 Q21540CT<br />

15 45 Q21545CTn<br />

15 50 Q21550CT<br />

20 20 Q22020CT<br />

20 25 Q22025CTn<br />

20 30 Q22030CT<br />

20 35 Q22035CTn<br />

20 40 Q22040CT<br />

20 45 Q22045CTn<br />

20 50 Q22050CT<br />

30 30 Q23030CT<br />

SHIPPING: 6 per carton, (Wt. 4.9 lbs.)<br />

Selection<br />

QT Duplex<br />

These space saver duplex breakers combine two<br />

independent 1/2" breaker poles in a common unit.<br />

This unit plugs into one load center stab and<br />

requires one panel space. HACR rated.<br />

QT Triplex<br />

These space saver triplex breakers provide<br />

a 2-pole common trip breaker for 120/240V AC<br />

circuits and two single poles for 120V AC circuits.<br />

Triplex require two panel spaces. HACR rated.<br />

Quadplex Circuit Breakers<br />

Ampere Rating<br />

Breaker<br />

Type<br />

QT<br />

2-Pole<br />

10K AIC<br />

120/240V AC<br />

Inner and<br />

Outter 2 Poles<br />

Common Trip<br />

Common-Trip<br />

2-Pole Outside<br />

Common-Trip<br />

2-Pole Inside<br />

Catalog<br />

Number<br />

15 15 Q21515CT2<br />

15 30 Q21530CT2<br />

20 20 Q22020CT2<br />

20 50 Q22050CT2<br />

30 20 Q23020CT2<br />

30 25 Q23025CT2<br />

30 30 Q23030CT2<br />

30 50 Q23050CT2<br />

40 20 Q24020CT2<br />

40 30 Q24030CT2<br />

40 40 Q24040CT2<br />

SHIPPING: 6 per carton, (Wt. 4.8 lbs.)<br />

QT Quadplex<br />

These space saver quadplex breakers provide<br />

two sets of common trip, two-pole breakers for<br />

120/240V AC circuits, and require two panel<br />

spaces. HACR rated.<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

For external accessories,<br />

please refer to page 7-158<br />

For inches / millimeters conversion, see Application Data<br />

section.<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

a Non-CTL. For replacement use only in panels manufactured<br />

before 1968<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-21


Circuit Breakers<br />

Special Application Breakers<br />

Selection<br />

HID Lighting<br />

For high-intensity discharge lamp loads having in-rush currents<br />

above the instantaneous trip setting of a standard breaker.<br />

Breaker<br />

Type<br />

QP<br />

1-Pole<br />

120V AC<br />

QP<br />

2-Pole<br />

120/240V AC<br />

Wiring<br />

Diagram<br />

Figure 1<br />

Figure 2<br />

Complete Breaker UL Unenclosed<br />

Ampere Rating Catalog Number<br />

15 Q115HID a n<br />

20 Q120HID a<br />

30 Q130HID<br />

15 Q215HID<br />

20 Q220HIDn<br />

30 Q230HIDn<br />

Molded Case Switch<br />

For applications that do not require overcurrent protection.<br />

QP<br />

1-Pole<br />

120V AC<br />

QP<br />

2-Pole<br />

120/240V AC<br />

Figure 1 100 Q1100S<br />

Figure 2<br />

30<br />

50<br />

60<br />

125<br />

Q230S<br />

Q250S<br />

Q260S<br />

Q2125S<br />

No-Noise<br />

For applications that require a reduction in the 60-cycle hum of<br />

a standard breaker.<br />

QP<br />

2-Pole<br />

120/240V AC<br />

Figure 2<br />

50<br />

60<br />

Q250NNn<br />

Q260NN<br />

Switching Neutral<br />

Figure 1 Figure 2<br />

Figure 3 Figure 4<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Switching Neutrals<br />

Used where all conductors are required to be disconnected.<br />

Neutral pole of the circuit breaker does not connect to load<br />

center bus. One side is wired to neutral and the other side to<br />

the device.<br />

QG<br />

2-Wire<br />

Common Trip<br />

120V AC<br />

QG<br />

3-Wire<br />

Common Trip<br />

120/240V AC<br />

Figure 3<br />

15<br />

20<br />

QG215<br />

QG220<br />

Figure 4 20 QG320<br />

Wiring Diagrams<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

Note: All circuit breakers on this page are 10K AIC<br />

a UL Listed as SWD (Switching Duty) Rated, suitable for 120V AC Fluorescent Lighting.<br />

7-22<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Circuit Breakers<br />

3/4 Inch Plug-In Breakers Selection<br />

Features<br />

b 3/4" format<br />

b HACR Rated<br />

b UL Classified for use in certain Square D<br />

load centers<br />

Type QD Circuit Breakers<br />

The Type QD circuit breaker line is<br />

available in 1-pole and 2-pole common<br />

trip versions listed on this page.<br />

The circuit breakers are UL Classified<br />

and UL Listed.<br />

All QD breakers are supplied with load<br />

side connectors suitable for 60/75°C<br />

wire and are calibrated for 40°C<br />

maximum ambient applications.<br />

UL Classified<br />

Siemens Type QD circuit breakers are<br />

UL Classified for use in specific Square<br />

D load centers in place of Square D Type<br />

QO ® circuit breakers. A Panelboard<br />

Compatibility List packaged with each<br />

QD breaker shows which type QD<br />

circuit breakers are acceptable for<br />

use in Square D load centers.<br />

The interrupting rating on these circuit<br />

breakers is 10,000A IR maximum and<br />

they are not series rated with Square D<br />

circuit breakers or equipment. This UL<br />

Classification allows a Siemens Type QD<br />

circuit breaker to be used in place of a<br />

Square D Type QO circuit breaker in<br />

those load centers that are specifically<br />

shown on the Panelboard Compatibility<br />

list. For additional information, contact<br />

your local Siemens sales engineer.<br />

1-Pole<br />

2-Pole<br />

Continuous<br />

Current Rating 120V<br />

120/240V Common Trip<br />

@ 40°C<br />

Catalog Number<br />

Catalog Number<br />

15 D115 a D215<br />

20 D120 a D220<br />

30 D130 D230<br />

40 D140 D240<br />

50 D150 D250<br />

60 D160 D260<br />

D120<br />

D220<br />

Shipping Weights<br />

Number of Number Per Shipping<br />

Poles Carton Weight (lbs.)<br />

1 16 3.8<br />

2 8 4.2<br />

Panelboard Compatibility List<br />

Listed Panelboards—Square D—Catalog Numbers<br />

QO2L30F/S<br />

QO2-4L70F/S<br />

QO2-4L70TS<br />

QO2-4L70RB<br />

QO6-12L100F/S<br />

QO6-12L100DF/S<br />

QO6-12L100TF/S<br />

QO6-12L100DTF/S<br />

QO6-12L100RB<br />

QO8-16L100F/S<br />

QO8-16L100DF/S<br />

QO8-16L100TF/S<br />

QO8-16L100DTF/S<br />

QO8-16L100RB<br />

QO112M100/RB<br />

QO116M100/RB<br />

QO120M100/RB<br />

QO124M100<br />

QO12L100DF/S<br />

QO12L100RB<br />

QO12-20M100/RB<br />

QO12-20M100TF/S<br />

QO12M100/RB<br />

QO16-20M100/RB<br />

QO16M100/RB<br />

QO20M100/RB<br />

QO112L125G/RB<br />

QO112-24L125G/RB<br />

QO112-24L125GWGC<br />

QO116L125G<br />

QO116-24L125G/RB<br />

QO12-24L125/RB<br />

QO120-24L125G<br />

QO120-24L125GWGC<br />

QO120L125G<br />

QO124L125G/RB<br />

QO124M125/RB<br />

QO16L125/RB<br />

QO16-12M125FTRB<br />

QO16-24L125/RB<br />

QO20L125/RB<br />

QO20-24L125/RB<br />

QO24L125/RB<br />

QO120-30L150G<br />

QO120-30M150/RB<br />

QO124L150G<br />

QO124M150<br />

QO130L150G/RB<br />

QO130M150/RB<br />

QO16L150/RB<br />

QO16M150/RB<br />

QO16-30L150/RB<br />

QO18-16M150FTRB<br />

QO20-30M150/RB<br />

QO20-30M150TF/S<br />

QO20-30L150<br />

QO24L150/RB<br />

QO24M150/RB<br />

QO30L150/RB<br />

QO30M150/RB<br />

QO8-16M200FT/RB<br />

QO112L200G/RB<br />

QO120-40M200/RB<br />

QO120-40M200TC<br />

QO124M200<br />

QO130L200G/RB<br />

QO130-40M200<br />

QO130M200/RB<br />

QO130-40L200G/RB<br />

QO140M200/RB<br />

QO16L200/RB<br />

QO16M200/RB<br />

QO18-16M200FTRB<br />

QO20-40L200/RB<br />

QO20-40M200TF/S<br />

QO20-40M200/RB<br />

QO24L200/RB<br />

QO24M200/RB<br />

QO30L200/RB<br />

QO30M200/RB<br />

QO30-40L200/RB<br />

QO30-40M200/RB<br />

QO40M200/RB<br />

QO140M225<br />

QO142L225G/RB<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

For inches / millimeters conversion, see Application Data<br />

section.<br />

a UL Listed for frequent switching applications (SWD).<br />

120V AC Fluorescent Lighting. One or two load<br />

conductors.<br />

Product Category RESI<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-23


Circuit Breakers<br />

Main and Branch Circuit Breakers a<br />

Revised on 10/31/18<br />

Selection<br />

Breaker<br />

Type<br />

QN<br />

2-Pole<br />

120/240V AC<br />

QNH<br />

2-Pole<br />

120/240V AC<br />

Ampere<br />

Rating<br />

Catalog<br />

Number<br />

Catalog<br />

Number<br />

150 QN2150 QN2150R b 10<br />

175 QN2175n QN2175R b n 10<br />

200 QN2200 QN2200R b 10<br />

150 QN2150H QN2150RH b 22<br />

175 QN2175Hn QN2175RH b n 22<br />

200 QN2200H QN2200RH b 22<br />

150 HQN2150 HQN2150R b 65<br />

175 HQN2175n — 65<br />

UL Interrupting<br />

Ratings (kA)<br />

HQN<br />

2-Pole<br />

120/240V AC 200 HQN2200 HQN2200R b 65<br />

Requires 4 panel spaces, 2 adjacent and 2 opposite. SHIPPING: 1 per carton (Wt. 3 lbs.)<br />

Main Breaker Kits<br />

For use in Ultimate Load Centersd For use in EQIII Load Centers<br />

UL<br />

Type<br />

Ampere<br />

Rating<br />

Catalog<br />

Number<br />

UL<br />

Type<br />

Ampere<br />

Rating<br />

Catalog<br />

Number<br />

EQ8681 100 MBK100A EQ9675 100 MBK100 22<br />

EQ8682 125 MBK125A EQ9677 125 MBK125 22<br />

EQ8693 150 MBK150A EQ9683 150 MBK150 22<br />

— — — EQ9684 175 MBK175n 22<br />

EQ8695 200 MBK200A EQ9685 200 MBK200 22<br />

EQ8696 225 MBK225A EQ9686 225 MBK225 22<br />

UL Interrupting<br />

Ratings (kA)<br />

QNR e<br />

EQ9675<br />

QN e<br />

Breaker<br />

Type<br />

QPJ c<br />

3-Pole<br />

240V AC<br />

Ampere<br />

Rating<br />

Catalog<br />

Number<br />

125 QPJ3125 10<br />

150 QPJ3150 10<br />

200 QPJ3200 10<br />

UL Interrupting<br />

Ratings (kA)<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Requires 6 spaces due to cross over design. Fits only EQIII 125-400A 3-phase<br />

load centers<br />

SHIPPING: 5 per carton (Wt. 17 lbs.)<br />

Breaker<br />

Type<br />

QPP<br />

2-Pole<br />

120/240V AC<br />

QPPH<br />

2-Pole<br />

120/240V AC<br />

HQPH<br />

2-Pole, 120/240V AC<br />

HQPP<br />

2-Pole<br />

120/240V AC<br />

HQPPH<br />

2-Pole<br />

120/240V AC<br />

Ampere<br />

Rating<br />

Catalog<br />

Number<br />

125 Q2125B 10<br />

150 Q2150B 10<br />

175 Q2175Bn 10<br />

200 Q2200B 10<br />

225 Q2225B 10<br />

125 Q2125BH 22<br />

150 Q2150BH 22<br />

175 Q2175BHn 22<br />

200 Q2200BH 22<br />

225 Q2225BHn 22<br />

100 HQ2100H 100<br />

125 HQ2125H 100<br />

125<br />

150<br />

175<br />

Obsolete<br />

200<br />

225<br />

100<br />

125<br />

150<br />

175<br />

Obsolete<br />

200<br />

225<br />

UL Interrupting<br />

Breaker Ratings (kA)<br />

Volts AC 120/240<br />

MBK<br />

MBK<br />

(100,125)A (150,200,225)A<br />

QPJ<br />

2-Pole QPP<br />

For inches / millimeters conversion, see Application Data section.<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

a All circuit breakers on this page are common trip.<br />

b Reverse handle.<br />

c CSA Listed.<br />

d MBK100A for use in 100 and 125A load centers.<br />

MBK125A for use in 125A load centers.<br />

MBK150A for use in 150, 200 and 225A load centers.<br />

MBK200A for use in 200 and 225A load centers.<br />

MBK225A for use in 225A load centers.<br />

MBK175A for use in 200 and 225A load centers.<br />

e QNR required for horizontal applications or vertical<br />

applications where the lugs are facing up. The QN<br />

breaker is required for vertical applications where the<br />

lugs are facing down as shown.<br />

7-24<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Circuit Breakers<br />

Revised on 10/31/18<br />

Main and Branch Circuit Breakers<br />

QS Breaker <br />

PowerMod's core offering of residential Meter Stacks, type WMM, offers the<br />

widest product offering & flexibility in the industry. Each meter stack houses the<br />

QuickSystem features to maximize productivity and minimize labor costs. To<br />

further simplify installation, our 225 Amp meter stacks feature the QS breaker.<br />

The QS breaker adds to the Siemens exclusive feature set in our Power Mod<br />

product line. Benefits and part numbers include:<br />

Front View<br />

▪ An exclusive side wired design saves wiring space and eliminates<br />

difficult "S bends"<br />

▪ No need for costly filler plates — QS 225 Amp breaker takes the<br />

same space as standard 100 Amp QPs<br />

▪ Single right hand bend wiring - saves time and wire<br />

▪ Provides 100K AIC flexibility from 100 up to 225 Amps<br />

▪ 10K to 100K AIC Series Rating<br />

QS Breaker<br />

Breaker Type QS QSH QSHH HQS HQSH<br />

Amperage 10K AIC 22K AIC 42K AIC 65K AIC 100K AIC<br />

100 QS2100 QS2100H QSH2100 QS2100HH HQS2100H<br />

110 QS2110 QS2110H QSH2110 QS2110HH HQS2110H<br />

125 QS2125 QS2125H QSH2125 QS2125HH HQS2125H<br />

150 QS2150 QS2150H QSH2150 QS2150HH HQS2150H<br />

175 QS2175 QS2175H QSH2175 QS2175HH HQS2175H<br />

200 QS2200 QS2200H QSH2200 QS2200HH HQS2200H<br />

225 QS2225 QS2225H QSH2225 QS2225HH HQS2225H<br />

QS Breaker Dimension Drawing<br />

1.00<br />

.19<br />

.58<br />

.96<br />

7<br />

7.89<br />

1.38<br />

CAUTION<br />

PRECAUCION<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

4.31<br />

000A<br />

000000<br />

ON<br />

20<br />

2.22<br />

NEUTRAL<br />

.99<br />

OFF<br />

20<br />

.19<br />

1.39<br />

1.34<br />

.28<br />

.16<br />

2.01<br />

2.38<br />

2.56<br />

2.66<br />

.37<br />

2.12<br />

1.06<br />

1.16<br />

For PowerMod information, please refer to<br />

Section 2, page 2-49<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-25


Circuit Breakers<br />

Line Diagrams<br />

Dimension Drawings<br />

1-Pole 2-Pole 3-Pole<br />

3"<br />

2 3 /8"<br />

3 1 /8"<br />

QP, QPH, HQP<br />

Type QT<br />

Type QPF, QPHF, QE, QAF2, QAF2H<br />

7<br />

Type EQ8681, EQ8682<br />

Type EQ8693, EQ8695, EQ8696<br />

Type QPJ<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Type QN, QNH, HQN<br />

Type QNR, QNRH, HQNR<br />

Type QPP, QPPH, HQPP, HQPPH<br />

a All standard circuit breakers are calibrated to 40°C maximum<br />

ambient application.<br />

7-26<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Circuit Breakers<br />

Lug Data<br />

Revised on 10/31/18<br />

Reference<br />

Circuit Breaker Type<br />

Circuit Breaker<br />

Ampere Rating<br />

LOAD SIDE<br />

Cables<br />

Per Connector<br />

Connector<br />

Wire Range<br />

QP, QPH, HQP, Plug-in 10 1 or 2 #14-#16 AWG Cu<br />

15–35<br />

40–50<br />

55-125<br />

QP 1 & 2-Pole Only 55-60 1<br />

QT 15–35<br />

QPF, QPHF 15–30<br />

QAF2, QAFH2, QFGA2,<br />

QFGAH2<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

40 1 #8 AWG CU-Al<br />

40–50 Exception:<br />

1 & 2-pole QP at 55-60<br />

40–60<br />

15–20<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

#14–#6 AWG Cu<br />

#14–#6 AWG Al<br />

#8–#6 AWG Cu<br />

#8–#4 AWG Al<br />

#8-#2/0 AWG Cu<br />

#8-#2/0 AWG Al<br />

#6-#4 AWG Cu-Al<br />

(#3 AWG compatible with QPH & HQP)<br />

#14–#6 AWG Cu<br />

#14–#6 AWG Al<br />

#8–#6 AWG Cu<br />

#8–#4 AWG Al<br />

#14–#10 AWG Cu<br />

#12–#8 AWG Al<br />

#8–#6 AWG Cu<br />

#8–#4 AWG Al<br />

#14–#12 AWG Cu<br />

#12–#10 AWG Al<br />

QD 15–20 2 #14–#10 AWG Cu Only<br />

1<br />

#14–#12 AWG Cu<br />

15–20<br />

1<br />

#12–#10 AWG Al<br />

25–35<br />

40–60<br />

1<br />

1<br />

1<br />

1<br />

#10–#8 AWG Cu<br />

#10–#6 AWG Al<br />

#8–#6 AWG Cu<br />

#8–#4 AWG Al<br />

QN, QNH, HQN 150–200 1 #1–300kcmil Cu-Al<br />

QS, QSH, QSHH, HQS, HQSH 100–225 1 #3–300kcmil Cu-Al<br />

EQ8681-Ultimate, PL, ES 100 1 #4–3/0 AWG Cu-Al<br />

EQ8682-Ultimate, PL, ES 125 1 #4–3/0 AWG Cu-Al<br />

EQ8693-Ultimate, PL, ES 150 1 #1–300kcmil Cu-Al<br />

EQ8695-Ultimate, PL, ES 200 1 #1–300kcmil Cu-Al<br />

EQ8696-Ultimate, PL, ES 225 1 #1–300kcmil Cu-Al<br />

QPP, QPPH, HQPP, HQPPH 125<br />

150<br />

175<br />

200<br />

225<br />

EQ9675-EQIII 100<br />

EQ9677-EQIII 125<br />

EQ9683-EQIII 150<br />

EQ9684 175<br />

EQ9685-EQIII 200<br />

EQ9686-EQIII 225<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

#1 AWG Cu<br />

#2/0 AWG Al<br />

#1/0 AWG Cu<br />

#3/0 AWG Al<br />

#2/0 AWG Cu<br />

#4/0 AWG Al<br />

#3/0 AWG Cu<br />

250kcmil AWG Al<br />

#4/0 AWG Cu<br />

300kcmil AWG Al<br />

#8-#2/0 AWG Cu<br />

#8-#2/0 AWG Al<br />

#8-#2/0 AWG Cu<br />

#8-#2/0 AWG Al<br />

#1/0 AWG Cu<br />

#3/0 AWG Al<br />

#3/0 AWG Cu<br />

250kcmil AWG Al<br />

#2/0 AWG Cu<br />

#4/0 AWG Al<br />

#4/0 AWG Cu<br />

300kcmil AWG Al<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

QPJ 125–200 1 #2–300kcmil Cu-Al<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-27


Surge Protection<br />

Circuit Breaker and Surge Protective Device (SPD)<br />

Features<br />

n 2 inch wide plug-on design<br />

— Includes (2) 1 Pole circuits breakers<br />

— No loss of load center spaces<br />

n Easy to install and perfect for retrofit<br />

n LEDs provide protection status<br />

Circuit Breaker and<br />

Surge Protective Device (SPD)<br />

Benefits<br />

By installing a Siemens Circuit Breaker and Surge Protective Device (SPD) in the<br />

load center of the residence, surge protection is provided for all branch circuits .<br />

Two green LED indicator lights are provided to show that surge protection is provided<br />

for all circuits connected to the load center. These breakers should be used<br />

for circuit protection of frequently used household or facility circuits because the<br />

lights and devices connected to these circuits provide an effective indication that<br />

surge protection is being provided.<br />

The circuit breaker and SPD utilize Siemens-built 150V AC, 40mm, metal oxide<br />

varistors (MOVs). The maximum impulse rating for the SPD module is 40kA. The<br />

standard interrupting rating for the circuit breakers is 10k AIC. All Type QP circuit<br />

breakers and SPD are plug-on style, with load terminals provided. The devices<br />

are rated for 120/240V AC and are calibrated for 40 degrees C maximum ambient<br />

applications.<br />

Breaker Type Ampere Rating Catalog Number Surge Type<br />

QP<br />

1- Pole<br />

120/240V AC<br />

10K AIC<br />

(2) 15<br />

(2) 20<br />

QSA1515SPD<br />

QSA2020SPD<br />

SPD<br />

SPD<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Catalog Number<br />

Amperage<br />

Number of Poles<br />

Initial Clamping Level<br />

Transient Energy Rating<br />

Transient Suppression<br />

Voltage Rating<br />

Peak Current Rating (impulse)<br />

Discharge Voltage Characteristic<br />

Discharge Current Withstand Rating<br />

Circuit Breaker Interrupting Rating<br />

Listings/Certifications<br />

QSA1515SPD<br />

QSA2020SPD<br />

15 or 20 Amp<br />

(2) 1-Pole Circuit Breakers<br />

240 Volts<br />

360 Joules line-to-neutral<br />

720 Joules line-to-line<br />

500 volts peak, line-to-neutral<br />

1000 volts peak, line-to-line<br />

40,000 amperes<br />

@ 1,500A, 600 volts<br />

@ 5,000A, 800 volts<br />

(both line-to-neutral)<br />

10,000 amperes<br />

line-to-neutral<br />

10,000A, 120/240V AC<br />

UL, CSA<br />

Meets UL 1449 4th Edition<br />

For warranty information please refer to the surge<br />

website www.usa.siemens.com/surge<br />

7-28<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI


Molded Case Circuit Breakers<br />

Panelboard Mounting with INSTA-WIRE<br />

Selection<br />

1-Pole Bolt-On (120/240V AC) e Description Catalog Number<br />

Type BL a Type BLH a Type HBL a<br />

Continuous<br />

10,000A IR 22,000A IR 65,000A IR<br />

Current Rating<br />

@ 40° C Catalog Number Catalog Number Catalog Number<br />

10 B110 — —<br />

15 B115 d B115H d B115HH d<br />

20 B120 d B120H d B120HH d<br />

25 B125 B125H B125HHn<br />

30 B130 B130H B130HH<br />

35 B135 B135Hn B135HHn<br />

40 B140 B140H B140HH<br />

45 B145n B145Hn B145HHn<br />

50 B150 B150H B150HHn<br />

60 B160 B160Hn B160HHn<br />

70 B170 B170Hn B170HHn<br />

2-Pole Bolt-On (Common-Trip 120/240V AC) f<br />

10 B210 — —<br />

15 B215 B215H B215HH<br />

20 B220 B220H B220HH<br />

25 B225 B225Hn B225HHn<br />

30 B230 B230H B230HH<br />

35 B235 B235Hn B235HHn<br />

40 B240 B240H B240HH<br />

45 B245 B245Hn B245HHn<br />

50 B250 B250H B250HH<br />

60 B260 B260H B260HH<br />

70 B270 B270Hn B270HHn<br />

80 B280 B280Hn B280HHn<br />

90 B290 B290Hn B290HHn<br />

100 B2100 B2100H B2100HH<br />

110 B2110n B2110Hn B2110HHn<br />

125 B2125 B2125H B2125HHn<br />

1-Pole<br />

2-Pole<br />

3-Pole<br />

2-Pole Bolt-On (Common-Trip 240V AC) cf<br />

15 B215R — —<br />

20 B220R — —<br />

30 B230R — —<br />

40 B240Rn — —<br />

50 B250R — —<br />

3-Pole Bolt-On (Common-Trip 240V AC) g<br />

15 B315 B315H B315HH<br />

20 B320 B320H B320HH<br />

25 B325 B325H B325HHn<br />

30 B330 B330H B330HH<br />

35 B335 B335Hn B335HHn<br />

40 B340 B340H B340HH<br />

45 B345 B345Hn B345HHn<br />

50 B350 B350H B350HH<br />

60 B360 B360H B360HH<br />

70 B370 B370H B370HH<br />

80 B380 B380Hn B380HH<br />

90 B390 B390Hn B390HH<br />

100 B3100 B3100H B3100HH<br />

Breaker<br />

Dimensions<br />

Type Amperes L D1 D2<br />

BL, BLH 15–50 3 9 ⁄16 2 3 ⁄8 3<br />

BL, BLH 55–125 3 3 ⁄4 2 3 ⁄8 3<br />

HBL 15–125 3 3 ⁄4 2 3 ⁄8 3<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

BL/BLH/HBL Internal Accessories<br />

Modifications<br />

Description Catalog Number Field/Factory Installed<br />

120VAC Shunt Trip add suffix...00S01n Factory<br />

24VAC Shunt Trip add suffix...00S07n Factory<br />

120V Auxiliary Switch add suffix...01n b Factory<br />

400Hz Calibration<br />

Marine 50˚C Ambient<br />

Calibration<br />

Fungus Proofing<br />

add suffix...Y h<br />

add suffix...M<br />

add suffix...F<br />

For external<br />

accessories, please<br />

refer to page 7-158<br />

n Built to order. Allow 2-3 weeks for delivery<br />

a UL Listed for use with 60/75° wire through 40 amps,<br />

UL listed for use with 75° wire only for 50 amps<br />

and above, HACR rated. 120V AC Fluorescent Lighting.<br />

b1A and 1B contacts.<br />

cUL Listed for use on 3-phase grounded “B” systems —<br />

10,000 for this application.<br />

dUL Listed for frequent switching applications (SWD).<br />

eShipped 12 per sleeve.<br />

fShipped 6 per sleeve.<br />

gShipped 4 per sleeve.<br />

hUL Listed 5KA IR.<br />

i10 Amp breaker does not have INSTA-WIRE.<br />

jFor 3 Phase Applications.<br />

UL Listed for reverse feed."<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-29


Molded Case Circuit Breakers<br />

Panelboard Mounting Circuit Breakers<br />

Revised on 09/30/19<br />

Selection<br />

Arc-Fault Circuit Interrupters (AFCI)<br />

AFCI’s detect arcing faults (an unintentional arcing condition in a circuit) that<br />

standard circuit breakers are unable to detect. The device is intended to mitigate<br />

the effects of arcing faults by functioning to de-energize the circuit when an arcfault<br />

is detected.<br />

Combination Type AFCI<br />

Detects all three possible types of arc fault: line-to-ground, line-to-neutral, and series.<br />

Breaker<br />

Type<br />

BAF2/BAFH2/HBAF2<br />

1-Pole 120V AC<br />

BAF/BAFH<br />

2-Pole 120/240V AC<br />

Ampere<br />

Rating<br />

Dual Function AFCI/GFCI<br />

10,000 A IR<br />

Catalog Number<br />

22,000 A IR<br />

Catalog Number<br />

65,000 A IR<br />

Catalog Number<br />

15 BA115AFC a BA115AFCHn BA115AFCHHn<br />

20 BA120AFC a BA120AFCHn BA120AFCHHn<br />

15 B215AFC a B215AFCHn —<br />

20 B220AFC a B220AFCHn —<br />

The Dual Function Circuit Breaker combines Combination Type AFCI and GFCI, protecting<br />

against both Arc Faults and (5mA) Ground Faults. The device includes the Self Test<br />

feature, making it the first in class in electrical safety for homeowners.<br />

BFGA2/BFGAH2/<br />

HBFGA2<br />

1-Pole 120V AC<br />

15<br />

20<br />

B115DF<br />

B120DF<br />

B115DFHn<br />

B120DFHn<br />

B115DFHHn<br />

B120DFHHn<br />

• UL Listed<br />

1-Pole Combination<br />

Type AFCI<br />

• HACR Rated<br />

2-Pole Combination<br />

Type AFCI<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Ground-Fault Circuit<br />

Interrupters (GFCI)<br />

Provides Class A (5mA) ground fault<br />

protection. Intended for personnel<br />

protection. De-energizes the circuit for all<br />

ungrounded conductors of the circuit.<br />

Breaker<br />

Type<br />

BLF2/<br />

BLHF2<br />

1-Pole<br />

120V AC<br />

Bolt-On<br />

BLF/<br />

BLHF<br />

2-Pole<br />

120/240V<br />

AC<br />

Bolt-On<br />

Amp<br />

Rating<br />

15<br />

20<br />

25<br />

30<br />

15<br />

20<br />

30<br />

40<br />

50<br />

60<br />

10k A IR<br />

Cat. No.<br />

BF115A a<br />

BF120A a<br />

BF125A<br />

BF130A<br />

BF215A<br />

BF220A<br />

BF230A<br />

BF240A<br />

BF250A<br />

BF260A<br />

22k A IR<br />

Cat. No.<br />

BF115AH a<br />

BF120AH a<br />

BF125AHn<br />

BF130AH<br />

BF215AHn<br />

BF220AH<br />

BF230AH<br />

BF240AHn<br />

BF250AHn<br />

BF260AHn<br />

65k A IR<br />

Cat. No.<br />

BF115AHHn<br />

BF120AHHn<br />

BF125AHHn<br />

BF130AHHn<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

Ground Fault Equipment<br />

Protection (30mA)<br />

Provides protection of equipment from<br />

damaging line-to-ground faults currents.<br />

De-energizes the circuit for all<br />

ungrounded conductors of the circuit.<br />

Breaker<br />

Type<br />

BLE/<br />

BLEH<br />

1-Pole,<br />

120V AC<br />

Bolt-On<br />

BLE/<br />

BLEH<br />

2-Pole<br />

120/240V<br />

AC<br />

Bolt-On<br />

Amp<br />

Rating<br />

15<br />

20<br />

30<br />

15<br />

20<br />

30<br />

40<br />

50<br />

60<br />

10k A IR<br />

Cat. No.<br />

BE115 a<br />

BE120 a<br />

BE130<br />

BE215<br />

BE220<br />

BE230<br />

BE240<br />

BE250<br />

BE260<br />

22k A IR<br />

Cat. No.<br />

BE115Hn a<br />

BE120Hn a<br />

BE130Hn<br />

BE215Hn<br />

BE220Hn<br />

BE230Hn<br />

BE240Hn<br />

BE250Hn<br />

BE260Hn<br />

1-Pole Dual<br />

Function AFCI/GFC<br />

BAF2/BLF2/BLE Accessories<br />

Description<br />

Catalog Number<br />

Padlocking Device 1-Pole ECPLD1<br />

Padlocking Device 2-Pole ECPLD2<br />

Handle Block<br />

ECBX231M<br />

Wiring Diagrams<br />

1-Pole Equipment<br />

Protection<br />

2-Pole Equipment<br />

Protection<br />

n Built to order. Allow 8 -10 weeks for delivery.<br />

a UL Listed as SWD (Switching Duty) Rated, suitable for<br />

120V AC Fluorescent Lighting.<br />

7-30<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

Panelboard Mounting Circuit Breakers<br />

Selection<br />

Special Application Breakers<br />

Switching Neutrals a<br />

Breaker<br />

Type<br />

BLG<br />

2-Wire<br />

Common Trip<br />

BLG<br />

3-Wire<br />

Common Trip<br />

HID Lighting a<br />

Ampere<br />

Rating<br />

15<br />

20<br />

Catalog Number<br />

BG215 n<br />

BG220 n<br />

30 BG330 n<br />

For high-intensity discharge lamp loads having in-rush<br />

currents above the instantaneous trip setting of a standard<br />

breaker.<br />

BL<br />

1-Pole<br />

BL<br />

2-Pole<br />

Molded Case Switch<br />

15 B115HID b n<br />

20 B120HID b<br />

30 B130HID n<br />

15 B215HID b n<br />

20 B220HID b<br />

30 B230HID n<br />

For applications that do not require overcurrent protection.<br />

BL<br />

30 B230S<br />

2-Pole<br />

2-Wire<br />

Switching Neutrals<br />

3-Wire<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

a HACR rated.<br />

b UL Listed for frequent switching applications (SWD). 120V AC fluorescent lighting.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-31


Molded Case Circuit Breakers<br />

BQD 100A Frame Panelboard Mounting Circuit Breakers<br />

BQD d<br />

1-Pole 2-Pole c 3-Pole c<br />

Continuous Current 277V AC–125V DC<br />

480Y/277V AC–<br />

125/250V DC 480Y/277V AC<br />

Rating @ 40°C<br />

Catalog Number Catalog Number Catalog Number<br />

15 BQD115 a b BQD215 e BQD315 e<br />

20 BQD120 a b BQD220 e BQD320 e<br />

25 BQD125 b BQD225 e BQD325 e<br />

30 BQD130 b BQD230 e BQD330 e<br />

35 BQD135 b BQD235 e BQD335 e<br />

40 BQD140 b BQD240 e BQD340 e<br />

45 BQD145 b n BQD245 e BQD345 e<br />

50 BQD150 b BQD250 e BQD350 e<br />

60 BQD160 BQD260 BQD360<br />

70 BQD170n BQD270 BQD370<br />

80 BQD180n BQD280 BQD380<br />

90 BQD190n BQD290 BQD390<br />

100 BQD1100n BQD2100 BQD3100<br />

BQD6 CSA Certified<br />

Continuous Current<br />

Rating @ 40°C<br />

1-Pole 2-Pole c 3-Pole c<br />

347V AC 600/347V AC 600/347V AC<br />

Catalog Number Catalog Number Catalog Number<br />

15 BQD6115 a BQD6215 BQD6315<br />

20 BQD6120 a BQD6220 BQD6320<br />

25 BQD6125n BQD6225n BQD6325n<br />

30 BQD6130 BQD6230 BQD6330<br />

35 BQD6135n BQD6235n BQD6335n<br />

40 BQD6140n BQD6240n BQD6340<br />

45 BQD6145n BQD6245n BQD6345n<br />

50 BQD6150n BQD6250n BQD6350<br />

60 BQD6160n BQD6260n BQD6360<br />

70 BQD6170n BQD6270n BQD6370<br />

Shipping Weights<br />

Revised on 10/31/18<br />

Selection/Dimensions<br />

BQD, BQD6<br />

BQD, BQD6<br />

Number of Number per Shipping<br />

Poles Carton Weight (lbs.) (ea.)<br />

1 1/12/48 1.6<br />

2 1/6/24 1.2<br />

3 1/4/16 2.0<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Interrupting Ratings (max. RMS symmetrical amperes kA)<br />

Breaker<br />

Type<br />

UL<br />

Volts AC<br />

Number<br />

of Poles 120 240 277<br />

480/<br />

277 347<br />

IEC 947-2 f<br />

Volts AC<br />

Volts DC 220/240 380/415<br />

600/ 125/<br />

347 125 250 I cu I cs I cu I cs<br />

BQD 1-Pole 65 — 14 — — — 14 — 18 9 — —<br />

2-Pole — 65 — 14 — — — 14 65 33 18 9<br />

3-Pole — 65 — 14 — — — 14 65 33 18 9<br />

BQD6 1-Pole — — — — 10 — 14 — 18 9 — —<br />

2-Pole — — — — — 10 — 14 65 33 18 9<br />

3-Pole — — — — — 10 — — 65 33 18 9<br />

Lugs For 60/75°C Wire<br />

BQD – Load End Only<br />

15–40 #14–#6 AWG Cu<br />

#12–#6 AWG Al<br />

45–100 #8–#1 AWG Cu<br />

#6–#1/0 AWG Al<br />

For inches / millimeters conversion,<br />

see Application Data section.<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

a SWD rated for switching fluorescent lighting.<br />

b HID rated at 277V AC.<br />

c Not suitable for 3-phase delta 480V applications.<br />

d HACR rated.<br />

e HID rated at 480Y/277V AC.<br />

f Applicable for 15-30A breakers only<br />

For external accessories, please refer<br />

to pages 7-160 to 7-165<br />

For internal accessories, please refer<br />

to page 7-35<br />

7-32<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

GB Frame<br />

Revised on 05/31/18<br />

Selection<br />

Type NGB Frame (Panelboard Mount)<br />

Continuous<br />

1-Pole 2-Pole 3-Pole<br />

Current Rating<br />

@ 40°C<br />

Catalog Number Catalog Number Catalog Number<br />

15 NGB1B015B a b NGB2B015B b NGB3B015B b<br />

20 NGB1B020B a b NGB2B020B b NGB3B020B b<br />

25 NGB1B025B b NGB2B025B b NGB3B025B b<br />

30 NGB1B030B b NGB2B030B b NGB3B030B b<br />

35 NGB1B035B b NGB2B035B b NGB3B035B b<br />

40 NGB1B040B b NGB2B040B b NGB3B040B b<br />

45 NGB1B045B b NGB2B045B b NGB3B045B b<br />

50 NGB1B050B b NGB2B050B b NGB3B050B b<br />

60 NGB1B060B NGB2B060B NGB3B060B<br />

70 NGB1B070B NGB2B070B NGB3B070B<br />

80 NGB1B080B NGB2B080B NGB3B080B<br />

90 NGB1B090B NGB2B090B NGB3B090B<br />

100 NGB1B100B NGB2B100B NGB3B100B<br />

110 NGB1B110B NGB2B110B NGB3B110B<br />

125 NGB1B125B NGB2B125B NGB3B125B<br />

Load lugs are included as standard. HACR rated.<br />

Type HGB (Panelboard Mount)<br />

Continuous<br />

Current Rating<br />

1-Pole 2-Pole 3-Pole<br />

@ 40°C<br />

Catalog Number Catalog Number Catalog Number<br />

15 HGB1B015B a b HGB2B015B b HGB3B015B b<br />

20 HGB1B020B a b HGB2B020B b HGB3B020B b<br />

25 HGB1B025B b HGB2B025B b HGB3B025B b<br />

30 HGB1B030B b HGB2B030B b HGB3B030B b<br />

35 HGB1B035B b HGB2B035B b HGB3B035B b<br />

40 HGB1B040B b HGB2B040B b HGB3B040B b<br />

45 HGB1B045B b HGB2B045B b HGB3B045B b<br />

50 HGB1B050B b HGB2B050B b HGB3B050B b<br />

60 HGB1B060B HGB2B060B HGB3B060B<br />

70 HGB1B070B HGB2B070B HGB3B070B<br />

80 HGB1B080B HGB2B080B HGB3B080B<br />

90 HGB1B090B HGB2B090B HGB3B090B<br />

100 HGB1B100B HGB2B100B HGB3B100B<br />

110 HGB1B110B HGB2B110B HGB3B110B<br />

125 HGB1B125B HGB2B125B HGB3B125B<br />

Shipping Weights<br />

Number of Number per Shipping<br />

Poles Carton Weight lbs. (kg)<br />

1 1 0.9 (0.4)<br />

2 1 1.9 (0.9)<br />

3 1 2.9 (1.2)<br />

Lugs for 60/75°C Wire<br />

Type<br />

NGB<br />

HGB<br />

LGB<br />

Ampere<br />

Rating<br />

15-30A<br />

35-125A<br />

NGB1B030B<br />

Type LGB (Panelboard Mount)<br />

Continuous<br />

Current Rating<br />

1-Pole 2-Pole 3-Pole<br />

@ 40°C<br />

Catalog Number Catalog Number Catalog Number<br />

15 LGB1B015B a b LGB2B015B b LGB3B015B b<br />

20 LGB1B020B a b LGB2B020B b LGB3B020B b<br />

25 LGB1B025B b LGB2B025B b LGB3B025B b<br />

30 LGB1B030B b LGB2B030B b LGB3B030B b<br />

35 LGB1B035B b LGB2B035B b LGB3B035B b<br />

40 LGB1B040B b LGB2B040B b LGB3B040B b<br />

45 LGB1B045B b LGB2B045B b LGB3B045B b<br />

50 LGB1B050B b LGB2B050B b LGB3B050B b<br />

60 LGB1B060B LGB2B060B LGB3B060B<br />

70 LGB1B070B LGB2B070B LGB3B070B<br />

80 LGB1B080B LGB2B080B LGB3B080B<br />

90 LGB1B090B LGB2B090B LGB3B090B<br />

100 LGB1B100B LGB2B100B LGB3B100B<br />

110 LGB1B110B LGB2B110B LGB3B110B<br />

125 LGB1B125B LGB2B125B LGB3B125B<br />

Catalog<br />

Wire Size<br />

Number<br />

#14-#6 AWG Cu TC1Q1 (qty. 1)<br />

#12-#6 AWG Al 3TC1Q1 (qty. 3)<br />

#8-1/0 AWG Cu<br />

#8-2/0 AWG Al<br />

3TC1GG20<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Interrupting Ratings (max. RMS symmetrical amperes kA)<br />

NGB<br />

HGB<br />

LGB<br />

UL489<br />

Volts AC<br />

Volts DC<br />

Poles 120 240 277 347 480Y/277 600Y/347 125 125/250<br />

1 100 — 25 14 — — 14 —<br />

2,3 — 100 — — 25 14 — 14 <br />

1 100 — 35 14 — — 14 —<br />

2,3 — 100 — — 35 14 — 14 <br />

1 100 — 65 14 — — 14 —<br />

2,3 — 100 — — 65 14 — 14 <br />

a SWD rated.<br />

b HID rated.<br />

c 2-pole only.<br />

2-pole only or two outer poles of 3-pole breaker<br />

UL Listed for reverse feed.<br />

For external accessories, please refer<br />

to pages 7-160 to 7-165<br />

For internal accessories, please refer<br />

to page 7-35<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-33


Molded Case Circuit Breakers<br />

GB2 Frame<br />

Revised on 10/31/18<br />

Selection<br />

Type NGB2 g (Panelboard Mount)<br />

Continuous<br />

1-Pole 2-Pole 3-Pole<br />

Current Rating<br />

@ 40°C<br />

Catalog Number Catalog Number Catalog Number<br />

15 NGB1K015B a b NGB2K015B b NGB3K015B b<br />

20 NGB1K020B a b NGB2K020B b NGB3K020B b<br />

25 NGB1K025B b NGB2K025B b NGB3K025B b<br />

30 NGB1K030B b NGB2K030B b NGB3K030B b<br />

35 NGB1K035B b NGB2K035B b NGB3K035B b<br />

40 NGB1K040B b NGB2K040B b NGB3K040B b<br />

45 NGB1K045B b NGB2K045B b NGB3K045B b<br />

50 NGB1K050B b NGB2K050B b NGB3K050B b<br />

60 NGB1K060B NGB2K060B NGB3K060B<br />

70 NGB1K070B NGB2K070B NGB3K070B<br />

80 NGB1K080B NGB2K080B NGB3K080B<br />

90 NGB1K090B NGB2K090B NGB3K090B<br />

100 NGB1K100B NGB2K100B NGB3K100B<br />

110 NGB1K110B NGB2K110B NGB3K110B<br />

125 NGB1K125B NGB2K125B NGB3K125B<br />

Load lugs are included as standard. HACR rated.<br />

LGB3K125B<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Type HGB2 g (Panelboard Mount)<br />

Continuous<br />

Current Rating<br />

1-Pole 2-Pole 3-Pole<br />

@ 40°C<br />

Catalog Number Catalog Number Catalog Number<br />

15 HGB1K015B a b HGB2K015B b HGB3K015B b<br />

20 HGB1K020B a b HGB2K020B b HGB3K020B b<br />

25 HGB1K025B b HGB2K025B b HGB3K025B b<br />

30 HGB1K030B b HGB2K030B b HGB3K030B b<br />

35 HGB1K035B b HGB2K035B b HGB3K035B b<br />

40 HGB1K040B b HGB2K040B b HGB3K040B b<br />

45 HGB1K045B b HGB2K045B b HGB3K045B b<br />

50 HGB1K050B b HGB2K050B b HGB3K050B b<br />

60 HGB1K060B HGB2K060B HGB3K060B<br />

70 HGB1K070B HGB2K070B HGB3K070B<br />

80 HGB1K080B HGB2K080B HGB3K080B<br />

90 HGB1K090B HGB2K090B HGB3K090B<br />

100 HGB1K100B HGB2K100B HGB3K100B<br />

110 HGB1K110B HGB2K110B HGB3K110B<br />

125 HGB1K125B HGB2K125B HGB3K125B<br />

Shipping Weights<br />

Number of<br />

Poles<br />

Number per<br />

Carton<br />

1 1 .75 (.34)<br />

2 1 1.3 (.59)<br />

3 1 2.0 (.98)<br />

Shipping<br />

Weight lbs. (kg)<br />

Lugs for 60/75°C Wire<br />

Type<br />

NGB2<br />

HGB2<br />

LGB2<br />

Ampere<br />

Rating<br />

15-30A<br />

35-125A<br />

Type LGB2 g (Panelboard Mount)<br />

Continuous<br />

Current Rating<br />

1-Pole 2-Pole 3-Pole<br />

@ 40°C<br />

Catalog Number Catalog Number Catalog Number<br />

15 LGB1K015B a b LGB2K015B b LGB3K015B b<br />

20 LGB1K020B a b LGB2K020B b LGB3K020B b<br />

25 LGB1K025B b LGB2K025B b LGB3K025B b<br />

30 LGB1K030B b LGB2K030B b LGB3K030B b<br />

35 LGB1K035B b LGB2K035B b LGB3K035B b<br />

40 LGB1K040B b LGB2K040B b LGB3K040B b<br />

45 LGB1K045B b LGB2K045B b LGB3K045B b<br />

50 LGB1K050B b LGB2K050B b LGB3K050B b<br />

60 LGB1K060B LGB2K060B LGB3K060B<br />

70 LGB1K070B LGB2K070B LGB3K070B<br />

80 LGB1K080B LGB2K080B LGB3K080B<br />

90 LGB1K090B LGB2K090B LGB3K090B<br />

100 LGB1K100B LGB2K100B LGB3K100B<br />

110 LGB1K110B LGB2K110B LGB3K110B<br />

125 LGB1K125B LGB2K125B LGB3K125B<br />

Catalog<br />

Wire Size<br />

Number<br />

#14-#6 AWG Cu TC1Q1 (qty. 1)<br />

#12-#6 AWG Al 3TC1Q1 (qty. 3)<br />

#8-1/0 AWG Cu<br />

#8-2/0 AWG Al<br />

3TC1GG20<br />

Interrupting Ratings (max. RMS symmetrical amperes kA)<br />

UL 489<br />

Type<br />

NGB2<br />

HGB2<br />

LGB2<br />

Volts AC<br />

Volts DC<br />

Poles 120 240 277 480 347 600Y/347 125 125/250<br />

1 100 — 25 — 14 — 14 —<br />

2, 3 — 100 — 25 — 14 — 14 <br />

1 100 — 35 — 22 — 14 —<br />

2, 3 — 100 — 35 — 22 — 14 <br />

1 100 — 65 — 25 — 14 —<br />

2, 3 — 100 — 65 — 25 — 14 <br />

a SWD rated.<br />

b HID rated.<br />

c 2-pole only.<br />

2-pole only or two outer poles of 3-pole breaker<br />

Suitable for reverse feed applications<br />

f 3 pole breakers suitable for single phase applications<br />

g xGB2 breakers require different strap kits than xGB. Refer to<br />

Section 11 for specific catalog numbers.<br />

For external accessories, please refer<br />

to pages 7-160 to 7-165<br />

For internal accessories, please refer<br />

to page 7-35<br />

7-34<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

Accessories a<br />

Revised on 05/04/17<br />

Selection<br />

Shunt Trip<br />

BQD, BQD6, CQD, CQD6,<br />

Control Voltage<br />

NGG, HGG, LGG, NGB, HGB,<br />

LGB, NGB2, HGB2 and LGB2<br />

V AC V DC Catalog Number<br />

120 — CQDST120<br />

240 — CQDST240s<br />

277 — CQDST277s<br />

480 — CQDST480s<br />

600 — CQDST600<br />

— 012 CQDST12<br />

— 024 CQDST24<br />

— 048 CQDST48<br />

— 125 CQDST125<br />

Auxiliary Switch<br />

Maximum<br />

Voltage<br />

Number<br />

of<br />

Contacts<br />

AC DC<br />

240 125 1A–1B CQDA1<br />

240 125 2A–2B CQDA2<br />

BQD, BQD6, CQD,<br />

CQD6, NGG, HGG, LGG,<br />

NGB, HGB, LGB, NGB2,<br />

HGB2 and LGB2<br />

Catalog Number<br />

CQDST120AAS<br />

Alarm Switch<br />

Maximum Voltage<br />

AC DC<br />

240 125 CQDBA<br />

BQD, BQD6, CQD, CQD6,<br />

NGG, HGG, LGG, NGB, HGB,<br />

LGB, NGB2, HGB2 and LGB2<br />

Catalog Number<br />

Shunt Trip and Auxiliary Switch<br />

Combinations<br />

Shunt Trip<br />

Voltage<br />

AC<br />

DC<br />

BQD, BQD6, CQD, CQD6,<br />

NGG, HGG, LGG, NGB, HGB,<br />

LGB, NGB2, HGB2 and LGB2<br />

Catalog Number<br />

24 — CQDST24AASs<br />

120 — CQDST120AASs<br />

240 — CQDST240AASs<br />

277 — CQDST277AASs<br />

480 — CQDST480AASs<br />

600 — CQDST600AASs<br />

— 12 CQDST12DASs<br />

— 24 CQDST24DASs<br />

— 48 CQDST48DASs<br />

— 125 CQDST125DASs<br />

CQD with Accessory Installed<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Alarm and Auxiliary Switch<br />

Combinations<br />

For Breaker<br />

BQD, BQD6, CQD, CQD6,<br />

NGG, HGG, LGG, NGB,<br />

HGB, LGB, NGB2, HGB2<br />

and LGB2<br />

Catalog Number<br />

CQDA1BAs<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

aAdds 1-pole space for accessory.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-35


3VA Molded Case Circuit Breakers<br />

3VA41 125A Thermal-magnetic Trip Circuit Breakers<br />

Revised on 09/30/20<br />

Selection<br />

3VA41 125A Frame, 1-Pole Thermal-Magnetic Trip Unit<br />

Cont.<br />

Ampere<br />

Rating<br />

S-Interrupting Class<br />

(SEAB)<br />

M-Interrupting Class<br />

(MEAB)<br />

H-Interrupting Class<br />

(HEAB)<br />

Catalog Number Catalog Number Catalog Number<br />

TM210 FTFM<br />

15 3VA4195-4ED14-0AA0 3VA4195-5ED14-0AA0 3VA4195-6ED14-0AA0<br />

20 3VA4120-4ED14-0AA0 3VA4120-5ED14-0AA0 3VA4120-6ED14-0AA0<br />

25 3VA4125-4ED14-0AA0 3VA4125-5ED14-0AA0 3VA4125-6ED14-0AA0<br />

30 3VA4130-4ED14-0AA0 3VA4130-5ED14-0AA0 3VA4130-6ED14-0AA0<br />

35 3VA4135-4ED14-0AA0 3VA4135-5ED14-0AA0 3VA4135-6ED14-0AA0<br />

40 3VA4140-4ED14-0AA0 3VA4140-5ED14-0AA0 3VA4140-6ED14-0AA0<br />

45 3VA4145-4ED14-0AA0 3VA4145-5ED14-0AA0 3VA4145-6ED14-0AA0<br />

50 3VA4150-4ED14-0AA0 3VA4150-5ED14-0AA0 3VA4150-6ED14-0AA0<br />

60 3VA4160-4ED14-0AA0 3VA4160-5ED14-0AA0 3VA4160-6ED14-0AA0<br />

70 3VA4170-4ED14-0AA0 3VA4170-5ED14-0AA0 3VA4170-6ED14-0AA0<br />

80 3VA4180-4ED14-0AA0 3VA4180-5ED14-0AA0 3VA4180-6ED14-0AA0<br />

90 3VA4190-4ED14-0AA0 3VA4190-5ED14-0AA0 3VA4190-6ED14-0AA0<br />

100 3VA4110-4ED14-0AA0 3VA4110-5ED14-0AA0 3VA4110-6ED14-0AA0<br />

110 3VA4111-4ED14-0AA0 3VA4111-5ED14-0AA0 3VA4111-6ED14-0AA0<br />

125 3VA4112-4ED14-0AA0 3VA4112-5ED14-0AA0 3VA4112-6ED14-0AA0<br />

3VA41 125A 1-Pole<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

3VA41 125A Frame, 1 in 2-Pole Thermal-Magnetic Trip Unit<br />

Cont.<br />

Ampere<br />

Rating<br />

3VA41 125A Frame, 2-Pole Thermal-Magnetic Trip Unit<br />

Cont.<br />

Ampere<br />

Rating<br />

S-Interrupting Class<br />

(SEAB)<br />

S-Interrupting Class<br />

(SEAB)<br />

M-Interrupting Class<br />

(MEAB)<br />

M-Interrupting Class<br />

(MEAB)<br />

H-Interrupting Class<br />

(HEAB)<br />

Catalog Number Catalog Number Catalog Number<br />

TM210 FTFM a<br />

15 3VA4195-4ED54-0AA0 3VA4195-5ED54-0AA0 3VA4195-6ED54-0AA0<br />

20 3VA4120-4ED54-0AA0 3VA4120-5ED54-0AA0 3VA4120-6ED54-0AA0<br />

25 3VA4125-4ED54-0AA0 3VA4125-5ED54-0AA0 3VA4125-6ED54-0AA0<br />

30 3VA4130-4ED54-0AA0 3VA4130-5ED54-0AA0 3VA4130-6ED54-0AA0<br />

35 3VA4135-4ED54-0AA0 3VA4135-5ED54-0AA0 3VA4135-6ED54-0AA0<br />

40 3VA4140-4ED54-0AA0 3VA4140-5ED54-0AA0 3VA4140-6ED54-0AA0<br />

45 3VA4145-4ED54-0AA0 3VA4145-5ED54-0AA0 3VA4145-6ED54-0AA0<br />

50 3VA4150-4ED54-0AA0 3VA4150-5ED54-0AA0 3VA4150-6ED54-0AA0<br />

60 3VA4160-4ED54-0AA0 3VA4160-5ED54-0AA0 3VA4160-6ED54-0AA0<br />

70 3VA4170-4ED54-0AA0 3VA4170-5ED54-0AA0 3VA4170-6ED54-0AA0<br />

80 3VA4180-4ED54-0AA0 3VA4180-5ED54-0AA0 3VA4180-6ED54-0AA0<br />

90 3VA4190-4ED54-0AA0 3VA4190-5ED54-0AA0 3VA4190-6ED54-0AA0<br />

100 3VA4110-4ED54-0AA0 3VA4110-5ED54-0AA0 3VA4110-6ED54-0AA0<br />

110 3VA4111-4ED54-0AA0 3VA4111-5ED54-0AA0 3VA4111-6ED54-0AA0<br />

125 3VA4112-4ED54-0AA0 3VA4112-5ED54-0AA0 3VA4112-6ED54-0AA0<br />

H-Interrupting Class<br />

(HEAB)<br />

Catalog Number Catalog Number Catalog Number<br />

TM210 FTFM<br />

15 3VA4195-4ED24-0AA0 3VA4195-5ED24-0AA0 3VA4195-6ED24-0AA0<br />

20 3VA4120-4ED24-0AA0 3VA4120-5ED24-0AA0 3VA4120-6ED24-0AA0<br />

25 3VA4125-4ED24-0AA0 3VA4125-5ED24-0AA0 3VA4125-6ED24-0AA0<br />

30 3VA4130-4ED24-0AA0 3VA4130-5ED24-0AA0 3VA4130-6ED24-0AA0<br />

35 3VA4135-4ED24-0AA0 3VA4135-5ED24-0AA0 3VA4135-6ED24-0AA0<br />

40 3VA4140-4ED24-0AA0 3VA4140-5ED24-0AA0 3VA4140-6ED24-0AA0<br />

45 3VA4145-4ED24-0AA0 3VA4145-5ED24-0AA0 3VA4145-6ED24-0AA0<br />

50 3VA4150-4ED24-0AA0 3VA4150-5ED24-0AA0 3VA4150-6ED24-0AA0<br />

60 3VA4160-4ED24-0AA0 3VA4160-5ED24-0AA0 3VA4160-6ED24-0AA0<br />

70 3VA4170-4ED24-0AA0 3VA4170-5ED24-0AA0 3VA4170-6ED24-0AA0<br />

80 3VA4180-4ED24-0AA0 3VA4180-5ED24-0AA0 3VA4180-6ED24-0AA0<br />

90 3VA4190-4ED24-0AA0 3VA4190-5ED24-0AA0 3VA4190-6ED24-0AA0<br />

100 3VA4110-4ED24-0AA0 3VA4110-5ED24-0AA0 3VA4110-6ED24-0AA0<br />

110 3VA4111-4ED24-0AA0 3VA4111-5ED24-0AA0 3VA4111-6ED24-0AA0<br />

125 3VA4112-4ED24-0AA0 3VA4112-5ED24-0AA0 3VA4112-6ED24-0AA0<br />

3VA41 125A 1 in 2-Pole<br />

3VA41 125A 2-Pole<br />

Ordering Information<br />

The catalog numbers listed here are<br />

for complete, non-interchangable trip<br />

circuit breakers breakers with load<br />

lugs installed.<br />

All 3VA41 thermal-magnetic trip<br />

circuit breakers are UL listed for<br />

reverse feed applications.<br />

For NAVAL-rated 1, 2 or 3-P thermalmagnetic<br />

trip circuit breakers, change<br />

the 13th digit of the catalog number<br />

to the number "1". (For example, a<br />

35KA @480VAC, 40A, 3-pole, NAVAL<br />

rated 3VA41 would be catalog<br />

number 3VA4140-5ED31-1AA0)<br />

7-36<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA41 125A Thermal-magnetic Trip Circuit Breakers<br />

Revised on 09/30/20<br />

Selection<br />

3VA41 125A Frame, 3-Pole Thermal-Magnetic Trip Unit<br />

Cont.<br />

Ampere<br />

Rating<br />

S-Interrupting Class<br />

(SEAB)<br />

M-Interrupting Class<br />

(MEAB)<br />

H-Interrupting Class<br />

(HEAB)<br />

Catalog Number Catalog Number Catalog Number<br />

TM210 FTFM<br />

15 3VA4195-4ED34-0AA0 3VA4195-5ED34-0AA0 3VA4195-6ED34-0AA0<br />

20 3VA4120-4ED34-0AA0 3VA4120-5ED34-0AA0 3VA4120-6ED34-0AA0<br />

25 3VA4125-4ED34-0AA0 3VA4125-5ED34-0AA0 3VA4125-6ED34-0AA0<br />

30 3VA4130-4ED34-0AA0 3VA4130-5ED34-0AA0 3VA4130-6ED34-0AA0<br />

35 3VA4135-4ED34-0AA0 3VA4135-5ED34-0AA0 3VA4135-6ED34-0AA0<br />

40 3VA4140-4ED34-0AA0 3VA4140-5ED34-0AA0 3VA4140-6ED34-0AA0<br />

45 3VA4145-4ED34-0AA0 3VA4145-5ED34-0AA0 3VA4145-6ED34-0AA0<br />

50 3VA4150-4ED34-0AA0 3VA4150-5ED34-0AA0 3VA4150-6ED34-0AA0<br />

60 3VA4160-4ED34-0AA0 3VA4160-5ED34-0AA0 3VA4160-6ED34-0AA0<br />

70 3VA4170-4ED34-0AA0 3VA4170-5ED34-0AA0 3VA4170-6ED34-0AA0<br />

80 3VA4180-4ED34-0AA0 3VA4180-5ED34-0AA0 3VA4180-6ED34-0AA0<br />

90 3VA4190-4ED34-0AA0 3VA4190-5ED34-0AA0 3VA4190-6ED34-0AA0<br />

100 3VA4110-4ED34-0AA0 3VA4110-5ED34-0AA0 3VA4110-6ED34-0AA0<br />

110 3VA4111-4ED34-0AA0 3VA4111-5ED34-0AA0 3VA4111-6ED34-0AA0<br />

125 3VA4112-4ED34-0AA0 3VA4112-5ED34-0AA0 3VA4112-6ED34-0AA0<br />

Dimensions<br />

Shipping Weight<br />

Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg<br />

3VA41 1 1 (25.4) 5.1 (129.4) 3.6 (92.2) 0.62 0.28<br />

3VA41 1 in 2 2 (50.8) 5.1 (129.4) 3.6 (92.2) 0.94 0.43<br />

3VA41 2 2 (50.8) 5.1 (129.4) 3.6 (92.2) 1.13 0.51<br />

3VA41 3 3 (76.2) 5.1 (129.4) 3.6 (92.2) 1.64 0.74<br />

Connectors for 75C Wire for 3VA41<br />

Type<br />

Steel wrap around (Cu cable only),<br />

1 cable lugs<br />

Aluminum body lug small (Cu/Al<br />

cable), 1 cable lug<br />

Aluminum body lug (Cu/Al cable),<br />

1 cable lugs<br />

Aluminum body lug small with control<br />

wire tap (Cu/Al cable), 1 cable lug<br />

Aluminum body lug with control wire<br />

tap (Cu/Al cable), 1 cable lugs<br />

Copper body lug small (Cu cable only),<br />

1 cable lugs<br />

Copper body lug (Cu cable only),<br />

1 cable lugs<br />

Copper body lug small with control<br />

wire tap (Cu cable only), 1 cable lugs<br />

Copper body lug with control wire tap<br />

(Cu cable only), 1 cable lugs<br />

Min.<br />

cable size<br />

Max.<br />

cable size<br />

Catalog No.<br />

(kit of 3 lugs)<br />

AWG 14 3/0 3VA9133-0JA11<br />

AWG 14 AWG 10 3VA9133-0JB10<br />

AWG 14 3/0 3VA9133-0JB11<br />

AWG 14 AWG 10 3VA9133-0JG10<br />

AWG 14 3/0 3VA9133-0JG11<br />

AWG 14 AWG 10 3VA9133-0JD10<br />

AWG 14 2/0 3VA9133-0JD11<br />

AWG 14 AWG 10 3VA9133-0JK10<br />

AWG 14 2/0 3VA9133-0JK11<br />

4<br />

Internal accessories configuration<br />

Auxiliary switch<br />

Auxiliary switch<br />

Leading<br />

changeover switch<br />

Alarm switch<br />

Trip alarm switch<br />

Short circuit alarm switch<br />

Auxiliary release<br />

Shunt trip flexible<br />

Shunt trip left<br />

Residual current release<br />

Undervoltage release<br />

Universal release<br />

Other<br />

Cylinder lock (type Ronis)<br />

Trip Settings for 3VA41<br />

TM210 - FTFM<br />

I n (A) I r (A) I i (A)<br />

15 15 300<br />

20 20 300<br />

25 25 300<br />

30 30 300<br />

RMS Symmetrical Amperes (kA)<br />

35 35 350<br />

Volts AC (50/60 Hz)<br />

40 40 400<br />

Poles 120 240 277 347 480Y/277V 480 600Y/347V<br />

45 45 450<br />

50 50 500<br />

1 65 25 14<br />

60 60 600<br />

2, 3 65 25 25 14<br />

70 70 700<br />

1 85 35 18<br />

3VA UL Molded Case Circuit 80 Breakers 80 800<br />

2, 3 85 35 35Accessories 18 and Spare Parts 90 90 900<br />

1 150 65 25<br />

100 100 1000<br />

2, 3 150 65 65Internal accessories<br />

25<br />

110 110 1100<br />

Design<br />

125 125 1250<br />

Interrupting Ratings for 3VA41<br />

Interrupting<br />

Class<br />

S<br />

M<br />

H<br />

Breaker<br />

Type<br />

SEAB<br />

MEAB<br />

HEAB<br />

3VA4 Accessories<br />

Description<br />

Padlocking Device for 3VA4 breaker<br />

Catalog Number<br />

3VA9038-0LB11<br />

Slot No.:<br />

Type<br />

AUX_HQ x x x<br />

AUX_HQ_el x x x<br />

x<br />

AUX_HP<br />

x<br />

LCS_HQ<br />

LCS_HQ_el<br />

LCS_HP<br />

Type<br />

Type<br />

STF<br />

STL<br />

STL_el<br />

3VA4/3VA5<br />

125 A<br />

1 in 2-pole<br />

/2-pole<br />

23 22 21<br />

TAS_HQ x x<br />

TAS_HQ_el x x<br />

TAS_HP<br />

x<br />

SAS_HQ<br />

SAS_HQ_el<br />

RCR<br />

UVR<br />

UNI<br />

3VA41 125A 3-Pole<br />

x<br />

x<br />

x<br />

x<br />

125 A<br />

23 22 21 11 12 13<br />

x x x x x x<br />

x x x x x x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x x x x<br />

x x x x<br />

x x<br />

x<br />

x<br />

x<br />

x<br />

3VA4<br />

125 A<br />

3-pole<br />

125 A<br />

x<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-37


Circuit Breakers<br />

Lug-In/Lug-Out with INSTA-WIRE<br />

Revised on 10/31/18<br />

Selection<br />

All BQ/BQH/HBQ circuit breakers are supplied with load side lugs. If line side lugs are required, add suffix “L” to catalog number. Consult Siemens<br />

for any additional charge. All standard circuit breakers are calibrated for 40°C maximum ambient application.<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Type BQ Type BQH Type HBQ<br />

Continuous<br />

Current Rating 10,000A IR 22,000A IR 65,000A IR<br />

@ 40° C<br />

Catalog Number Catalog Number Catalog Number<br />

1-Pole (120/240V AC) e<br />

15 BQ1B015 d BQ1B015H d HB1B015n d<br />

20 BQ1B020 d BQ1B020H d HB1B020n d<br />

25 BQ1B025 BQ1B025Hn HB1B025n<br />

30 BQ1B030 BQ1B030H HB1B030n<br />

35 BQ1B035n BQ1B035Hn HB1B035n<br />

40 BQ1B040 BQ1B040H HB1B040n<br />

45 BQ1B045n — HB1B045n<br />

50 BQ1B050 BQ1B050H HB1B050n<br />

60 BQ1B060n BQ1B060Hn HB1B060n<br />

70 BQ1B070n BQ1B070Hn HB1B070n<br />

2-Pole (Common-Trip 120/240V AC) f<br />

15 BQ2B015 BQ2B015H HB2B015n<br />

20 BQ2B020 BQ2B020H HB2B020n<br />

25 BQ2B025 BQ2B025Hn HB2B025n<br />

30 BQ2B030 BQ2B030H HB2B030n<br />

35 BQ2B035 BQ2B035Hn HB2B035n<br />

40 BQ2B040 BQ2B040H HB2B040n<br />

45 BQ2B045 — HB2B045n<br />

50 BQ2B050 BQ2B050H HB2B050n<br />

60 BQ2B060 BQ2B060H HB2B060n<br />

70 BQ2B070 BQ2B070Hn HB2B070n<br />

80 BQ2B080 BQ2B080Hn HB2B080<br />

90 BQ2B090 BQ2B090Hn HB2B090n<br />

100 BQ2B100 BQ2B100H HB2B100<br />

110 BQ2B110 — HB2B110n<br />

125 BQ2B125 BQ2B125H HB2B125<br />

2-Pole (Common-Trip 240V AC) cf<br />

15 BQ2H015 — —<br />

20 BQ2H020 — —<br />

30 BQ2H030 — —<br />

40 BQ2H040n — —<br />

50 BQ2H050 — —<br />

60 BQ2H060 — —<br />

70 BQ2H070n — —<br />

80 BQ2H080n — —<br />

90 BQ2H090n — —<br />

100 BQ2H100n — —<br />

3-Pole (Common-Trip 240V AC) g<br />

15 BQ3B015 BQ3B015H HB3B015n<br />

20 BQ3B020 BQ3B020H HB3B020n<br />

25 BQ3B025n BQ3B025Hn HB3B025<br />

30 BQ3B030 BQ3B030H HB3B030<br />

35 BQ3B035n BQ3B035H HB3B035<br />

40 BQ3B040 BQ3B040H HB3B040<br />

45 BQ3B045n BQ3B045H HB3B045<br />

50 BQ3B050 BQ3B050H HB3B050<br />

60 BQ3B060 BQ3B060H HB3B060<br />

70 BQ3B070 BQ3B070H HB3B070n<br />

80 BQ3B080 BQ3B080Hn HB3B080n<br />

90 BQ3B090 BQ3B090Hn HB3B090n<br />

100 BQ3B100 BQ3B100H HB3B100<br />

BQ / BQH / HBQ Internal Accessories<br />

Description Catalog Number Field/Factory Installed<br />

120VAC Shunt Trip add suffix...00S01n Factory<br />

24VAC Shunt Trip add suffix...00S07n Factory<br />

120V Auxiliary Switch add suffix...01n b Factory<br />

Factory Modifications<br />

Description<br />

Catalog Number<br />

Line Side Lugs<br />

Quick Connect Lug<br />

400Hz Calibration<br />

Marine 50˚ C Ambient<br />

Calibration<br />

Fungus Proofing<br />

1-Pole<br />

2-Pole<br />

3-Pole<br />

add suffix...L<br />

add suffix...QX<br />

add suffix...Y h<br />

add suffix...M<br />

add suffix...F<br />

For external accessories, please refer<br />

to page 7-158<br />

n Built to order. Allow 2-3 weeks for delivery<br />

a UL Listed for use with 60/75° wire through 40 amps,<br />

UL listed for use with 75° wire only for 50 amps<br />

and above, HACR rated.<br />

b 1A and 1B contacts.<br />

c UL Listed for use on 3-phase grounded “B” systems —<br />

10,000 for this application.<br />

d UL Listed for frequent switching<br />

applications (SWD). 120V AC Fluorescent Lighting.<br />

e Shipped 12 per sleeve.<br />

f Shipped 6 per sleeve.<br />

g Shipped 4 per sleeve.<br />

h UL Listed 5KA IR.<br />

Refer to Table A on page 7-153<br />

7-38<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

DIN Rail Mounted Circuit Breakers<br />

Revised on 11/30/19<br />

Selection/Dimensions<br />

Breaker<br />

Type<br />

Ampere<br />

Rating<br />

Catalog<br />

Number<br />

Line Side<br />

Connector<br />

Load Side<br />

Connector<br />

Interrupting Ratings<br />

(KA) (RMS Symmetrical<br />

Amperes) Volts AC<br />

120 120/240<br />

1-Pole DIN Rail (120/240V AC)<br />

BQLD<br />

1-Pole<br />

120V<br />

DIN Rail<br />

BQXD<br />

1-Pole<br />

120V<br />

DIN Rail<br />

10 BQ1B010QLD TC1Q1 TC1Q1 10<br />

15 BQ1B015QLD TC1Q1 TC1Q1 10<br />

20 BQ1B020QLD TC1Q1 TC1Q1 10<br />

25 BQ1B025QLD TC1Q1 TC1Q1 10<br />

30 BQ1B030QLD TC1Q1 TC1Q1 10<br />

35 BQ1B035QLD TC1Q1 TC1Q1 10<br />

40 BQ1B040QLD TC1Q1 TC1Q1 10<br />

45 BQ1B045QLD TA1Q1 TA1Q1 10<br />

50 BQ1B050QLD TA1Q1 TA1Q1 10<br />

60 BQ1B060QLD TA1Q1 TA1Q1 10<br />

10 BQ1B010QXD TC1Q1 Quick-Connect 10<br />

15 BQ1B015QXD TC1Q1 Quick-Connect 10<br />

20 BQ1B020QXD TC1Q1 Quick-Connect 10<br />

25 BQ1B025QXD TC1Q1 Quick-Connect 10<br />

30 BQ1B030QXD TC1Q1 Quick-Connect 10<br />

35 BQ1B035QXD TC1Q1 Quick-Connect 10<br />

40 BQ1B040QXD TC1Q1 Quick-Connect 10<br />

45 BQ1B045QXD TA1Q1 Quick-Connect 10<br />

50 BQ1B050QXD TA1Q1 Quick-Connect 10<br />

60 BQ1B060QXD TA1Q1 Quick-Connect 10<br />

2-Pole DIN Rail (120/240V AC)<br />

BQLD<br />

2-Pole<br />

120/240V<br />

DIN Rail<br />

BQXD<br />

2-Pole<br />

120/240V<br />

DIN Rail<br />

10 BQ2B010QLD TC1Q1 TC1Q1 10<br />

15 BQ2B015QLD TC1Q1 TC1Q1 10<br />

20 BQ2B020QLD TC1Q1 TC1Q1 10<br />

25 BQ2B025QLD TC1Q1 TC1Q1 10<br />

30 BQ2B030QLD TC1Q1 TC1Q1 10<br />

35 BQ2B035QLD TC1Q1 TC1Q1 10<br />

40 BQ2B040QLD TC1Q1 TC1Q1 10<br />

45 BQ2B045QLD TA1Q1 TA1Q1 10<br />

50 BQ2B050QLD TA1Q1 TA1Q1 10<br />

60 BQ2B060QLD TA1Q1 TA1Q1 10<br />

10 BQ2B010QXD TC1Q1 Quick-Connect 10<br />

15 BQ2B015QXD TC1Q1 Quick-Connect 10<br />

20 BQ2B020QXD TC1Q1 Quick-Connect 10<br />

25 BQ2B025QXD TC1Q1 Quick-Connect 10<br />

30 BQ2B030QXD TC1Q1 Quick-Connect 10<br />

35 BQ2B035QXD TC1Q1 Quick-Connect 10<br />

40 BQ2B040QXD TC1Q1 Quick-Connect 10<br />

45 BQ2B045QXD TA1Q1 Quick-Connect 10<br />

50 BQ2B050QXD TA1Q1 Quick-Connect 10<br />

60 BQ2B060QXD TA1Q1 Quick-Connect 10<br />

BQ1B015QLD<br />

BQ1B015QXD<br />

BQ2B015QLD<br />

BQ2B015QXD<br />

7<br />

Lugs-For Use with BQXD <br />

Circuit Cab. Lug<br />

Breaker Per Wire Range Catalog<br />

Amp. Rtg. Lug AWG Number<br />

Line Side<br />

10–40<br />

1<br />

1<br />

#16–#6 Cu<br />

#12–#6 Al<br />

TC1Q1 ab<br />

45–125<br />

1<br />

1<br />

#8–#1 Cu<br />

#6–#1/0 Al<br />

TA1Q1<br />

Finger Safe Terminal Shield<br />

Protects against accidental contact with<br />

lugs–1 per lug. Fits line and load end.<br />

Catalog Number Qty<br />

BQFS2 2<br />

BQFS1K 1000<br />

BQ Enclosures<br />

Type<br />

Catalog Number d<br />

1 EB3100S c<br />

3R<br />

WB3100<br />

BQ Breaker Dimensions<br />

Dimensions (inches)<br />

Number of Poles Breaker Type Amperes L D1 D2<br />

1, 2 BQ 15-50 3¾ 2 3 ⁄8 3<br />

1, 2 BQH, HBQ 15-50 4 2 3 ⁄8 3<br />

1, 2 BQ, BQH, HBQ 55-125 4 2 3 ⁄8 3<br />

3 BQ, BQH, HBQ 15-100 4 2 3 ⁄8 3<br />

1, 2 BQXD 15-60 4½ 2 3 ⁄8 3<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

For inches / millimeters conversion,<br />

see Application Data section.<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

a UL Listed for use with 60/75° wire through 40 amps,<br />

UL listed for use with 75° wire only for 50 amps<br />

and above, HACR rated.<br />

bConnector has steel construction.<br />

cSurface mounted indoor. If flush mounting is required,<br />

replace suffix “S” in catalog number with suffix “F”.<br />

Neutral included in enclosure.<br />

Enclosure will not accept circuit breakers with shunt<br />

trips or auxiliary switches installed.<br />

Type BQXD uses TA1Q1 or TC1Q1 lugs on line side of<br />

circuit breaker.<br />

Enclosures, see Section 6<br />

For external accessories, please refer<br />

to pages 7-158, 7-160 to 7-165<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-39


Molded Case Circuit Breakers<br />

QR 250A Frame<br />

Revised on 05/04/17<br />

Selection/Dimensions<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Continuous<br />

Current Rating<br />

@ 40°C<br />

Type QR2 b<br />

2-Pole<br />

240V AC<br />

Catalog Number<br />

3-Pole<br />

240V AC<br />

Catalog Number<br />

100 QR22B100 QR23B100<br />

125 QR22B125 QR23B125<br />

150 QR22B150 QR23B150<br />

175 QR22B175 QR23B175<br />

200 QR22B200 QR23B200<br />

225 QR22B225 QR23B225<br />

250 QR22B250 QR23B250<br />

Type QRH2 b<br />

100 QRH22B100n QRH23B100<br />

125 QRH22B125 QRH23B125<br />

150 QRH22B150 QRH23B150<br />

175 QRH22B175n QRH23B175<br />

200 QRH22B200 QRH23B200<br />

225 QRH22B225 QRH23B225<br />

250 QRH22B250 QRH23B250<br />

Type HQR2 b<br />

100 HQR22B100n HQR23B100<br />

125 HQR22B125 HQR23B125<br />

150 HQR22B150 HQR23B150<br />

175 HQR22B175n HQR23B175<br />

200 HQR22B200 HQR23B200<br />

225 HQR22B225 HQR23B225<br />

250 HQR22B250 HQR23B250<br />

Type HQR2H b<br />

100 HQR22B100H HQR23B100H<br />

125 HQR22B125H HQR23B125H<br />

150 HQR22B150H HQR23B150H<br />

175 HQR22B175H HQR23B175H<br />

200 HQR22B200H HQR23B200H<br />

225 HQR22B225H HQR23B225H<br />

250 HQR22B250H HQR23B250H<br />

Ordering Information<br />

Load side 3TA1QR300 lugs are mounted and included<br />

when circuit breaker is ordered. For line and load lugs<br />

(3TA1QR300) installed at no additional charge, add<br />

suffix “L” to catalog number.<br />

50°C Calibration - See page 7-156.<br />

400HZ. - See page 7-156.<br />

Shipping Weights<br />

Number<br />

of Poles<br />

Lugs For 75°C Wire a<br />

Catalog<br />

Number<br />

UL 489 Interrupting Ratings<br />

Breaker<br />

Type<br />

Lug<br />

Body<br />

QR2 10<br />

QRH2 25<br />

HQR2 65<br />

HQR2H 100<br />

Lug<br />

Wire Range<br />

3TA1QR300 Al #3 - 300 Kcmil Al/Cu<br />

3TC1QR250 Cu #3 - 300 Kcmil Cu ONLY<br />

CCQ250 CMP<br />

Number<br />

per Carton<br />

2 1 3.2<br />

3 1 4.5<br />

Shipping<br />

Weight (lbs.)<br />

#6 AWG - 350kcmil Al/Cu<br />

Enclosures (Neutral Included)<br />

Catalog<br />

Type<br />

Number<br />

1 QR2N1S or QR2N1F<br />

3R<br />

QR2N3R3<br />

12 QR2N12<br />

4X<br />

QR2N4X<br />

4X316<br />

QR2N4X316<br />

RMS Symmetrical Amperes (kA)<br />

Volts AC (50/60 Hz)<br />

240<br />

7’’<br />

3’’<br />

2-pole<br />

4.5’’ 3-pole<br />

D<br />

2.53’’<br />

n Built to order. Allow 2–3 weeks for delivery. a See Note: A page 7-147.<br />

Note: QR breakers are UL Listed for reverse feed<br />

applications.<br />

b HACR rated.<br />

Enclosures Section 6<br />

For external accessories, please refer<br />

to pages 7-160 to 7-165<br />

7-40<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

QR Accessories<br />

Revised on 04/10/17<br />

Selection<br />

Shunt Trip<br />

Control Voltage<br />

Shunt Trip<br />

Shunt Trip and Auxiliary<br />

Switch Combination<br />

AC DC In Rush<br />

Catalog Number Catalog Number<br />

— 24 1.1A S07QR2 S07QR2A<br />

120 - 240 48 2.0A AC / 1.8A DC S01QR2 S01QR2A<br />

Auxiliary Switch<br />

Contains (1) or (2) sets of “A” contacts and “B” contacts<br />

Maximum Control<br />

Supply Voltage (V)<br />

Maximum Allowable<br />

Current (A)<br />

Single Auxiliary 1A -1B<br />

Contact Catalog Number<br />

Double Auxiliary 2A - 2B<br />

Contact Catalog Number<br />

250 AC /125 DC 5 AC / 0.5 DC A01QR2 A02QR2<br />

External Accessories<br />

Description<br />

Padlock Device<br />

Mounting Screw Kit<br />

Handle Blocking Device<br />

Handle Sliding-bar Interlock<br />

Catalog Number<br />

HPLQR<br />

MSQR3<br />

HBLQR<br />

SBMIQR<br />

Padlock Device HPLQR Handle Block Block Device HBLQR Mechanical Interlock SBMIQR<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-41


Molded Case Circuit Breakers<br />

CQD 100A Frame<br />

Type CQD (Cable In - Cable Out) DIN Rail Mount c<br />

1-Pole 2-Pole 3-Pole<br />

Continuous<br />

Current Rating<br />

277V AC<br />

125V DC<br />

480Y/277V AC<br />

125/250V DC 480Y/277V AC<br />

@ 40°C<br />

Catalog Number Catalog Number Catalog Number<br />

115 CQD115 ab CQD215 b CQD315 b<br />

120 CQD120 ab CQD220 b CQD320 b<br />

125 CQD125 b CQD225 b CQD325 b<br />

130 CQD130 b CQD230 b CQD330 b<br />

135 CQD135 b n CQD235 b n CQD335 b<br />

140 CQD140 b n CQD240 b CQD340 b<br />

145 CQD145 b n CQD245 b n CQD345 b n<br />

150 CQD150 b n CQD250 b CQD350 b<br />

160 CQD160n CQD260 CQD360<br />

170 CQD170n CQD270 CQD370<br />

180 CQD180n CQD280 CQD380<br />

190 CQD190n CQD290n CQD390<br />

100 CQD1100n CQD2100 CQD3100<br />

Shipping Weights<br />

Revised on 05/31/18<br />

Selection/Dimensions<br />

Number of Number per Shipping<br />

Poles Carton Weight lbs. (kg)<br />

1 1 0.5 (0)<br />

2 1 1.0 (0)<br />

3 1 1.5 (1)<br />

Lugs For 60/75°C Wire<br />

Amps<br />

Wire Size<br />

15–40 #14–#6 AWG Cu<br />

#12–#6 AWG Al<br />

45–100 #8–#1 AWG Cu<br />

#6–#1/0 AWG Al<br />

Interrupting Ratings (max. RMS symmetrical amperes kA)<br />

Breaker<br />

Type<br />

CQD<br />

UL<br />

Volts AC<br />

Number<br />

of Poles 120 240 277<br />

480/<br />

277<br />

IEC 947-2 d<br />

Volts AC<br />

Volts DC 220/240 380/415<br />

600/ 125/<br />

347 125 250 I cu I cs I cu I cs<br />

1-Pole 65 — 14 — — 14 — 18 9 — —<br />

2-Pole — 65 — 14 — — 14 65 33 18 9<br />

3-Pole — 65 — 14 — — 14 65 33 18 9<br />

CQD<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

CQD<br />

For inches / millimeters conversion, see Application Data section.<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

a SWD rated.<br />

Note: CQD breakers are UL Listed for reverse feed<br />

applications.<br />

b HID rated.<br />

c HACR rated.<br />

d Applicable for 15-30A breakers only.<br />

Enclosures Section 6<br />

Accessories pages 7-44 and 7-160 to 7-165<br />

7-42<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

GG 125A Frame<br />

Type NGG (Cable In - Cable Out)<br />

Continuous<br />

1-Pole 2-Pole 3-Pole<br />

Current Rating<br />

@ 40°C<br />

Catalog Number Catalog Number Catalog Number<br />

15 NGG1B015L a b NGG2B015L b NGG3B015L b<br />

20 NGG1B020L a b NGG2B020L b NGG3B020L b<br />

25 NGG1B025L b NGG2B025L b NGG3B025L b<br />

30 NGG1B030L b NGG2B030L b NGG3B030L b<br />

35 NGG1B035L b NGG2B035L b NGG3B035L b<br />

40 NGG1B040L b NGG2B040L b NGG3B040L b<br />

45 NGG1B045L b NGG2B045L b NGG3B045L b<br />

50 NGG1B050L b NGG2B050L b NGG3B050L b<br />

60 NGG1B060L NGG2B060L NGG3B060L<br />

70 NGG1B070L NGG2B070L NGG3B070L<br />

80 NGG1B080L NGG2B080L NGG3B080L<br />

90 NGG1B090L NGG2B090L NGG3B090L<br />

100 NGG1B100L NGG2B100L NGG3B100L<br />

110 NGG1B110L NGG2B110L NGG3B110L<br />

125 NGG1B125L NGG2B125L NGG3B125L<br />

GG<br />

2.9<br />

Revised on 11/30/19<br />

Selection/Dimensions<br />

5.4<br />

Line and load lugs are included as standard. If no lugs are required, remove the “L” suffix.<br />

HACR rated.<br />

Suitable for screws or DIN rail mounting.<br />

Type HGG (Cable In - Cable Out)<br />

Continuous<br />

Current Rating<br />

1-Pole 2-Pole 3-Pole<br />

@ 40°C Catalog Number Catalog Number Catalog Number<br />

15 HGG1B015L b HGG2B015L b HGG3B015L b<br />

20 HGG1B020L b HGG2B020L b HGG3B020L b<br />

25 HGG1B025L b HGG2B025L b HGG3B025L b<br />

30 HGG1B030L b HGG2B030L b HGG3B030L b<br />

35 HGG1B035L b HGG2B035L b HGG3B035L b<br />

40 HGG1B040L b HGG2B040L b HGG3B040L b<br />

45 HGG1B045L b HGG2B045L b HGG3B045L b<br />

50 HGG1B050L b HGG2B050L b HGG3B050L b<br />

60 HGG1B060L HGG2B060L HGG3B060L<br />

70 HGG1B070L HGG2B070L HGG3B070L<br />

80 HGG1B080L HGG2B080L HGG3B080L<br />

90 HGG1B090L HGG2B090L HGG3B090L<br />

100 HGG1B100L HGG2B100L HGG3B100L<br />

110 HGG1B110L HGG2B110L HGG3B110L<br />

125 HGG1B125L HGG2B125L HGG3B125L<br />

Shipping Weights<br />

Number of Number per Shipping<br />

Poles Carton Weight lbs. (kg)<br />

1 1 .75 (0.34)<br />

2 1 1.3 (0.59)<br />

3 1 2.0 (0.98)<br />

Lugs For 60/75°C Wire<br />

NGG<br />

Ampere Rating Wire Size Catalog Number<br />

15–30A #14–#6 AWG Cu TC1Q1 (qty. 1)<br />

#12–#6 AWG Al 3TC1Q1 (qty. 3)<br />

35–125A #8–1/0 AWG Cu<br />

#8–2/0 AWG Al<br />

3TC1GG20 (qty. 3)<br />

15–125A Nut Keeper plate w/ screw<br />

(for crimp terminals)<br />

TNKG3 (qty. 3)<br />

GG<br />

Type LGG (Cable In - Cable Out)<br />

Continuous<br />

Current Rating<br />

1-Pole 2-Pole 3-Pole<br />

@ 40°C Catalog Number Catalog Number Catalog Number<br />

15 LGG1B015L b LGG2B015L b LGG3B015L b<br />

20 LGG1B020L b LGG2B020L b LGG3B020L b<br />

25 LGG1B025L b LGG2B025L b LGG3B025L b<br />

30 LGG1B030L b LGG2B030L b LGG3B030L b<br />

35 LGG1B035L b LGG2B035L b LGG3B035L b<br />

40 LGG1B040L b LGG2B040L b LGG3B040L b<br />

45 LGG1B045L b LGG2B045L b LGG3B045L b<br />

50 LGG1B050L b LGG2B050L b LGG3B050L b<br />

60 LGG1B060L LGG2B060L LGG3B060L<br />

70 LGG1B070L LGG2B070L LGG3B070L<br />

80 LGG1B080L LGG2B080L LGG3B080L<br />

90 LGG1B090L LGG2B090L LGG3B090L<br />

100 LGG1B100L LGG2B100L LGG3B100L<br />

110 LGG1B110L LGG2B110L LGG3B110L<br />

125 LGG1B125L LGG2B125L LGG3B125L<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Interrupting Ratings (max. RMS symmetrical amperes kA)<br />

Breaker<br />

Type<br />

NGG<br />

HGG<br />

LGG<br />

UL489<br />

IEC 60947-2 (Ics = 50%Icu)<br />

Volts AC Volts DC Volts AC Volts DC<br />

Poles 120 240 277 347 480 600Y/347 125 125/250 240 415 125/250<br />

1 65 — 25 14 — — 14 — 25 — —<br />

2,3 — 65 — — 25 14 — 14 65 — 14<br />

1 — — 35 14 — — 14 — — — —<br />

2,3 — — — — 35 14 — 14 — — —<br />

1 — — 65 14 — — 14 — — — —<br />

2,3 — — — — 65 14 — 14 — — —<br />

For inches / millimeters conversion, see Application Data section.<br />

a b<br />

SWD rated.<br />

HID rated at 15-50A 1-pole @ 277 VAC; 2 & 3-pole @<br />

480 VAC<br />

Enclosures Section 6<br />

Accessories pages 7-44 and 7-160 to 7-165<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-43


Molded Case Circuit Breakers<br />

Accessories a<br />

Selection<br />

Shunt Trip<br />

BQD, BQD6, CQD,<br />

Control Voltage<br />

NGG, HGG, LGG, NGB,<br />

HGB and LGB<br />

V AC V DC Catalog Number<br />

120 — CQDST120<br />

240 — CQDST240s<br />

277 — CQDST277s<br />

480 — CQDST480s<br />

600 — CQDST600<br />

— 012 CQDST12<br />

— 024 CQDST24<br />

— 048 CQDST48<br />

— 125 CQDST125<br />

Auxiliary Switch<br />

Maximum<br />

Voltage<br />

AC DC<br />

Number<br />

of<br />

Contacts<br />

240 125 1A–1B CQDA1<br />

240 125 2A–2B CQDA2<br />

BQD, BQD6, CQD,<br />

NGG, HGG, LGG, NGB,<br />

HGB and LGB<br />

Catalog Number<br />

CQDST120AAS<br />

Alarm Switch<br />

Maximum Voltage<br />

AC DC<br />

240 125 CQDBA<br />

BQD, BQD6, CQD,<br />

NGG, HGG, LGG, NGB,<br />

HGB and LGB<br />

Catalog Number<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Shunt Trip and Auxiliary Switch<br />

Combinations<br />

Shunt Trip<br />

Voltage<br />

AC<br />

DC<br />

BQD, BQD6, CQD,<br />

NGG, HGG, LGG, NGB,<br />

HGB and LGB<br />

Catalog Number<br />

24 — CQDST24AASs<br />

120 — CQDST120AASs<br />

240 — CQDST240AASs<br />

277 — CQDST277AASs<br />

480 — CQDST480AASs<br />

600 — CQDST600AASs<br />

— 12 CQDST12DASs<br />

— 24 CQDST24DASs<br />

— 48 CQDST48DASs<br />

— 125 CQDST125DASs<br />

CQD with Accessory Installed<br />

Alarm and Auxiliary Switch<br />

Combinations<br />

For Breaker<br />

BQD, BQD6, CQD, NGG,<br />

HGG, LGG, NGB, HGB<br />

and LGB<br />

Catalog Number<br />

CQDA1BAs<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

aAdds 1-pole space for accessory.<br />

7-44<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

Notes<br />

<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-45


3VA Molded Case Circuit Breakers<br />

Revised on 04/30/20<br />

3VA UL Circuit Breakers<br />

Catalog Numbering Logic<br />

Breaker Designation<br />

Catalog Numbering System<br />

3VA 6 1 40 – 5 HL 3 1 – 0 A A0<br />

Breaker Designation<br />

Thermal magnetic panelboard breakers 4<br />

Thermal magnetic (Cable-in Cable-out) breakers 5<br />

Electronic trip breakers 6<br />

Frame Size<br />

125/150A 1<br />

250A 2<br />

400A 3<br />

600A 4<br />

800A 5<br />

1000A 6<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Rated Current<br />

3VA41/<br />

3VA51<br />

3VA52 3VA53 3VA54 3VA55 3VA61 3VA62 3VA63 3VA64 3VA65 3VA66<br />

15A 95<br />

20A 200A 200A 20<br />

225A 225A 22<br />

25A 250A 250A 250A 250A 25<br />

30A 300A 30<br />

35A 350A 35<br />

40A 40A 400A 40A 400A 400A 40<br />

45A 45A 450A 45<br />

50A 50A 500A 50<br />

60A 60A 600A 600A 600A 600A 60<br />

70A 70A 700A 70<br />

80A 80A 800A 800A 80<br />

90A 90A 90<br />

100A 100A 100A 100A 1000A 10<br />

110A 110A 11<br />

125A 125A 12<br />

150A 150A 15<br />

175A 17<br />

Interrupting Capacity @ 480V<br />

3VA4/3VA5 3VA6<br />

MCP/MCS 200K 0<br />

MCP/MCS MCP/MCS 1<br />

25K 4<br />

35K 35K 5<br />

65K 65K 6<br />

100K 100K 7<br />

150K 8<br />

Trip Unit Protection Functions (see next page for details)<br />

Number of Poles (see next page for details)<br />

Connection Technology (see next page for details)<br />

Regional Specifics (as applicable) (see next page for details)<br />

Auxixliary Releases (see next page for details)<br />

Auxiliary/Alarm Switches (see next page for details)<br />

7-46<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA UL Circuit Breakers<br />

Revised on 04/30/20<br />

Catalog Numbering System<br />

Catalog Numbering Logic (cont.)<br />

Breaker Designation<br />

(see previous page for details)<br />

3VA 6 1 40 – 5 HL 3 1 – 0 A A0<br />

Trip Unit Protection Functions<br />

3VA4/3VA5 L I N<br />

TM230 MCCB fix adj EC<br />

TM210 MCCB fix fix ED<br />

TM240 MCCB adj adj EF<br />

TM230 MCCB fix adj 100% GC<br />

TM210 MCCB fix fix 100% GD<br />

TM240 MCCB adj adj 100% GF<br />

TM110M MSP fix MG<br />

TM120M MSP adj MH<br />

TM120M MSP adj MU<br />

MCS110 MSC fix BB<br />

3VA6 L S I G N LCD com. measurement values<br />

ETU320 LI MCCB adj adj 0%/50%/100% HL<br />

ETU330 LIG MCCB adj adj adj 0%/50%/100% HM<br />

ETU350 LSI MCCB adj adj fix 0%/50%/100% HN<br />

ETU550 LSI MCCB adj adj adj 20/40%...100/160% yes yes standard JP<br />

ETU556 LSI(G) MCCB adj adj adj alarm 20/40%...100/160% yes yes standard JT<br />

ETU560 LSIG MCCB adj adj adj adj 20/40%...100/160% yes yes standard JQ<br />

ETU820 LI MCCB adj adj 20/40%...100/160% yes yes advanced KL<br />

ETU830 LIG MCCB adj adj adj 20/40%...100/160% yes yes advanced KM<br />

ETU850LSI MCCB adj adj adj 20/40%...100/160% yes yes advanced KP<br />

ETU856 LSI(G) MCCB adj adj adj alarm 20/40%...100/160% yes yes advanced KT<br />

ETU860 LSIG MCCB adj adj adj adj 20/40%...100/160% yes yes advanced KQ<br />

ETU310M MCP adj MS<br />

MCS110 MCS fix BB<br />

Number of Poles<br />

1 pole 1<br />

2 pole 2<br />

3 pole 3<br />

4 pole 4<br />

1-in-2 pole 5<br />

2-in-3 pole 6<br />

Connection Technology<br />

Blank, punched copper bar without any lugs 1<br />

Nut keeper kit, line and load 2<br />

Nut keeper kit, load end only 3<br />

Aluminum wire connector, load end only 4<br />

Wire connector, line end only 5<br />

Wire connector, line and load 6<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Regional Specifics (as applicable)<br />

Standard 0<br />

NAVAL/50C 1<br />

100% Rated (3VA6) 2<br />

Auxiliary Releases Without A<br />

Auxiliary/Alarm Switches Without A0<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-47


3VA Molded Case Circuit Breakers<br />

3VA51 125A Thermal-magnetic Trip Circuit Breakers<br />

Revised on 10/15/20<br />

Selection<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

3VA51 125A Frame, 1-Pole Thermal-Magnetic Trip Unit<br />

Cont.<br />

Ampere<br />

Rating<br />

S-Interrupting Class<br />

(SEAS)<br />

M-Interrupting Class<br />

(MEAS)<br />

H-Interrupting Class<br />

(HEAS)<br />

Catalog Number Catalog Number Catalog Number<br />

TM210 FTFM<br />

15 3VA5195-4ED11-0AA0 3VA5195-5ED11-0AA0 3VA5195-6ED11-0AA0<br />

20 3VA5120-4ED11-0AA0 3VA5120-5ED11-0AA0 3VA5120-6ED11-0AA0<br />

25 3VA5125-4ED11-0AA0 3VA5125-5ED11-0AA0 3VA5125-6ED11-0AA0<br />

30 3VA5130-4ED11-0AA0 3VA5130-5ED11-0AA0 3VA5130-6ED11-0AA0<br />

35 3VA5135-4ED11-0AA0 3VA5135-5ED11-0AA0 3VA5135-6ED11-0AA0<br />

40 3VA5140-4ED11-0AA0 3VA5140-5ED11-0AA0 3VA5140-6ED11-0AA0<br />

45 3VA5145-4ED11-0AA0 3VA5145-5ED11-0AA0 3VA5145-6ED11-0AA0<br />

50 3VA5150-4ED11-0AA0 3VA5150-5ED11-0AA0 3VA5150-6ED11-0AA0<br />

60 3VA5160-4ED11-0AA0 3VA5160-5ED11-0AA0 3VA5160-6ED11-0AA0<br />

70 3VA5170-4ED11-0AA0 3VA5170-5ED11-0AA0 3VA5170-6ED11-0AA0<br />

80 3VA5180-4ED11-0AA0 3VA5180-5ED11-0AA0 3VA5180-6ED11-0AA0<br />

90 3VA5190-4ED11-0AA0 3VA5190-5ED11-0AA0 3VA5190-6ED11-0AA0<br />

100 3VA5110-4ED11-0AA0 3VA5110-5ED11-0AA0 3VA5110-6ED11-0AA0<br />

110 3VA5111-4ED11-0AA0 3VA5111-5ED11-0AA0 3VA5111-6ED11-0AA0<br />

125 3VA5112-4ED11-0AA0 3VA5112-5ED11-0AA0 3VA5112-6ED11-0AA0<br />

3VA51 125A Frame, 2-Pole Thermal-Magnetic Trip Unit<br />

Cont.<br />

Ampere<br />

Rating<br />

S-Interrupting Class<br />

(SEAS)<br />

M-Interrupting Class<br />

(MEAS)<br />

H-Interrupting Class<br />

(HEAS)<br />

Catalog Number Catalog Number Catalog Number<br />

TM210 FTFM a<br />

15 3VA5195-4ED21-0AA0 3VA5195-5ED21-0AA0 3VA5195-6ED21-0AA0<br />

20 3VA5120-4ED21-0AA0 3VA5120-5ED21-0AA0 3VA5120-6ED21-0AA0<br />

25 3VA5125-4ED21-0AA0 3VA5125-5ED21-0AA0 3VA5125-6ED21-0AA0<br />

30 3VA5130-4ED21-0AA0 3VA5130-5ED21-0AA0 3VA5130-6ED21-0AA0<br />

35 3VA5135-4ED21-0AA0 3VA5135-5ED21-0AA0 3VA5135-6ED21-0AA0<br />

40 3VA5140-4ED21-0AA0 3VA5140-5ED21-0AA0 3VA5140-6ED21-0AA0<br />

45 3VA5145-4ED21-0AA0 3VA5145-5ED21-0AA0 3VA5145-6ED21-0AA0<br />

50 3VA5150-4ED21-0AA0 3VA5150-5ED21-0AA0 3VA5150-6ED21-0AA0<br />

60 3VA5160-4ED21-0AA0 3VA5160-5ED21-0AA0 3VA5160-6ED21-0AA0<br />

70 3VA5170-4ED21-0AA0 3VA5170-5ED21-0AA0 3VA5170-6ED21-0AA0<br />

80 3VA5180-4ED21-0AA0 3VA5180-5ED21-0AA0 3VA5180-6ED21-0AA0<br />

90 3VA5190-4ED21-0AA0 3VA5190-5ED21-0AA0 3VA5190-6ED21-0AA0<br />

100 3VA5110-4ED21-0AA0 3VA5110-5ED21-0AA0 3VA5110-6ED21-0AA0<br />

110 3VA5111-4ED21-0AA0 3VA5111-5ED21-0AA0 3VA5111-6ED21-0AA0<br />

125 3VA5112-4ED21-0AA0 3VA5112-5ED21-0AA0 3VA5112-6ED21-0AA0<br />

Dimensions<br />

Shipping Weight<br />

Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg<br />

3VA51 1 1 (25.4) 5.5 (140) 3 (76.5) 0.84 0.38<br />

3VA51 2 2 (50.8) 5.5 (140) 3 (76.5) 1.37 0.62<br />

3VA51 3 3 (76.2) 5.5 (140) 3 (76.5) 1.73 0.78<br />

3VA51 4 4 (101.6) 5.5 (140) 3 (76.5) 2.09 0.95<br />

Interrupting Ratings for 3VA51<br />

Interrupting<br />

Class<br />

S<br />

M<br />

H<br />

Breaker<br />

Type<br />

SEAS<br />

MEAS<br />

HEAS<br />

3VA51<br />

125A 1-Pole<br />

3VA51<br />

125A 2-Pole<br />

Ordering Information<br />

The catalog numbers listed here are<br />

for complete, non-interchangable trip<br />

circuit breakers without lugs.<br />

Order required lugs or connection<br />

technology separately for field<br />

installation.<br />

All 3VA51 thermal-magnetic trip<br />

circuit breakers are UL listed for<br />

reverse feed applications.<br />

For NAVAL-rated thermal-magnetic<br />

trip circuit breakers, change the 13th<br />

digit of the catalog number to the<br />

number "1". (For example, a 35KA<br />

@480VAC, 40A, 3-pole, NAVAL rated<br />

3VA51 would be catalog number<br />

3VA5140-5ED31-1AA0)<br />

RMS Symmetrical Amperes (kA)<br />

Volts AC (50/60 Hz)<br />

Volts DC<br />

Poles 120 240 277 347 480Y/277V 480 600Y/347V 125 250 500 b 600 b<br />

1 65 25 14 14<br />

2, 3, 4 65 25 25 14 14 50 50 50<br />

1 85 35 18 25<br />

2, 3, 4 85 35 35 18 25 85 85 85<br />

1 150 50 18 30<br />

2, 3, 4 150 65 65 25 30 100 100 100<br />

a Available with NAVAL/50C ratings.<br />

b Applies to 3VA51 3-Pole<br />

7-48<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA51 125A Thermal-magnetic Trip Circuit Breakers<br />

Revised on 02/28/19<br />

Selection<br />

3VA51 125A Frame, 3-Pole Thermal-Magnetic Trip Unit<br />

Cont.<br />

Ampere<br />

Rating<br />

S-Interrupting Class<br />

(SEAS)<br />

M-Interrupting Class<br />

(MEAS)<br />

H-Interrupting Class<br />

(HEAS)<br />

Catalog Number Catalog Number Catalog Number<br />

TM210 FTFM a<br />

15 3VA5195-4ED31-0AA0 3VA5195-5ED31-0AA0 3VA5195-6ED31-0AA0<br />

20 3VA5120-4ED31-0AA0 3VA5120-5ED31-0AA0 3VA5120-6ED31-0AA0<br />

25 3VA5125-4ED31-0AA0 3VA5125-5ED31-0AA0 3VA5125-6ED31-0AA0<br />

30 3VA5130-4ED31-0AA0 3VA5130-5ED31-0AA0 3VA5130-6ED31-0AA0<br />

35 3VA5135-4ED31-0AA0 3VA5135-5ED31-0AA0 3VA5135-6ED31-0AA0<br />

40 3VA5140-4ED31-0AA0 3VA5140-5ED31-0AA0 3VA5140-6ED31-0AA0<br />

45 3VA5145-4ED31-0AA0 3VA5145-5ED31-0AA0 3VA5145-6ED31-0AA0<br />

50 3VA5150-4ED31-0AA0 3VA5150-5ED31-0AA0 3VA5150-6ED31-0AA0<br />

60 3VA5160-4ED31-0AA0 3VA5160-5ED31-0AA0 3VA5160-6ED31-0AA0<br />

70 3VA5170-4ED31-0AA0 3VA5170-5ED31-0AA0 3VA5170-6ED31-0AA0<br />

80 3VA5180-4ED31-0AA0 3VA5180-5ED31-0AA0 3VA5180-6ED31-0AA0<br />

90 3VA5190-4ED31-0AA0 3VA5190-5ED31-0AA0 3VA5190-6ED31-0AA0<br />

100 3VA5110-4ED31-0AA0 3VA5110-5ED31-0AA0 3VA5110-6ED31-0AA0<br />

110 3VA5111-4ED31-0AA0 3VA5111-5ED31-0AA0 3VA5111-6ED31-0AA0<br />

125 3VA5112-4ED31-0AA0 3VA5112-5ED31-0AA0 3VA5112-6ED31-0AA0<br />

TM230 FTAM a<br />

15 3VA5195-4EC31-0AA0 3VA5195-6EC31-0AA0 3VA5195-6EC31-0AA0<br />

20 3VA5120-4EC31-0AA0 3VA5120-5EC31-0AA0 3VA5120-6EC31-0AA0<br />

25 3VA5125-4EC31-0AA0 3VA5125-5EC31-0AA0 3VA5125-6EC31-0AA0<br />

30 3VA5130-4EC31-0AA0 3VA5130-5EC31-0AA0 3VA5130-6EC31-0AA0<br />

35 3VA5135-4EC31-0AA0 3VA5135-5EC31-0AA0 3VA5135-6EC31-0AA0<br />

40 3VA5140-4EC31-0AA0 3VA5140-5EC31-0AA0 3VA5140-6EC31-0AA0<br />

45 3VA5145-4EC31-0AA0 3VA5145-5EC31-0AA0 3VA5145-6EC31-0AA0<br />

50 3VA5150-4EC31-0AA0 3VA5150-5EC31-0AA0 3VA5150-6EC31-0AA0<br />

60 3VA5160-4EC31-0AA0 3VA5160-5EC31-0AA0 3VA5160-6EC31-0AA0<br />

70 3VA5170-4EC31-0AA0 3VA5170-5EC31-0AA0 3VA5170-6EC31-0AA0<br />

80 3VA5180-4EC31-0AA0 3VA5180-5EC31-0AA0 3VA5180-6EC31-0AA0<br />

90 3VA5190-4EC31-0AA0 3VA5190-5EC31-0AA0 3VA5190-6EC31-0AA0<br />

100 3VA5110-4EC31-0AA0 3VA5110-5EC31-0AA0 3VA5110-6EC31-0AA0<br />

110 3VA5111-4EC31-0AA0 3VA5111-5EC31-0AA0 3VA5111-6EC31-0AA0<br />

125 3VA5112-4EC31-0AA0 3VA5112-5EC31-0AA0 3VA5112-6EC31-0AA0<br />

TM240 ATAM<br />

15 3VA5195-4EF31-0AA0 3VA5195-5EF31-0AA0 3VA5195-6EF31-0AA0<br />

20 3VA5120-4EF31-0AA0 3VA5120-5EF31-0AA0 3VA5120-6EF31-0AA0<br />

30 3VA5130-4EF31-0AA0 3VA5130-5EF31-0AA0 3VA5130-6EF31-0AA0<br />

40 3VA5140-4EF31-0AA0 3VA5140-5EF31-0AA0 3VA5140-6EF31-0AA0<br />

50 3VA5150-4EF31-0AA0 3VA5150-5EF31-0AA0 3VA5150-6EF31-0AA0<br />

60 3VA5160-4EF31-0AA0 3VA5160-5EF31-0AA0 3VA5160-6EF31-0AA0<br />

70 3VA5170-4EF31-0AA0 3VA5170-5EF31-0AA0 3VA5170-6EF31-0AA0<br />

80 3VA5180-4EF31-0AA0 3VA5180-5EF31-0AA0 3VA5180-6EF31-0AA0<br />

100 3VA5110-4EF31-0AA0 3VA5110-5EF31-0AA0 3VA5110-6EF31-0AA0<br />

3VA51 125A 3-Pole<br />

Ordering Information<br />

The catalog numbers listed here are<br />

for complete, non-interchangable trip<br />

circuit breakers without lugs.<br />

Order required lugs or connection<br />

technology separately for field<br />

installation.<br />

All 3VA51 thermal-magnetic trip<br />

circuit breakers are UL listed for<br />

reverse feed applications.<br />

For NAVAL-rated thermal-magnetic<br />

trip circuit breakers, change the 13th<br />

digit of the catalog number to the<br />

number "1". (For example, a 35KA<br />

@480VAC, 40A, 3-pole, NAVAL rated<br />

3VA51 would be catalog number<br />

3VA5140-5ED31-1AA0)<br />

Enclosures (3-pole only)<br />

Nema Type<br />

Catalog Number<br />

1 surface 3VAE125N1S<br />

1 flush 3VAE125N1F<br />

3R<br />

3VAE125N3R<br />

12 3VAE125N12<br />

4X (304)<br />

3VAE125N4X<br />

4X (316)<br />

3VAE125N4X316<br />

Neutral<br />

N250X<br />

200% Neutral N2250X<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Dimensions<br />

Shipping Weight<br />

Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg<br />

3VA51 1 1 (25.4) 5.5 (140) 3 (76.5) 0.84 0.38<br />

3VA51 2 2 (50.8) 5.5 (140) 3 (76.5) 1.37 0.62<br />

3VA51 3 3 (76.2) 5.5 (140) 3 (76.5) 1.73 0.78<br />

3VA51 4 4 (101.6) 5.5 (140) 3 (76.5) 2.09 0.95<br />

a Available with NAVAL/50C ratings.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-49


3VA Molded Case Circuit Breakers<br />

3VA51 125A Thermal-magnetic Trip Circuit Breakers<br />

Revised on 02/28/19<br />

Selection<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

3VA51 125A Frame, 4-Pole Thermal-Magnetic Trip Unit<br />

Cont.<br />

Ampere<br />

Rating<br />

S-Interrupting Class<br />

(SEAS)<br />

M-Interrupting Class<br />

(MEAS)<br />

H-Interrupting Class<br />

(HEAS)<br />

Catalog Number Catalog Number Catalog Number<br />

TM210 FTFM Unprotected Neutral<br />

15 3VA5195-4ED41-0AA0 3VA5195-5ED41-0AA0 3VA5195-6ED41-0AA0<br />

20 3VA5120-4ED41-0AA0 3VA5120-5ED41-0AA0 3VA5120-6ED41-0AA0<br />

25 3VA5125-4ED41-0AA0 3VA5125-5ED41-0AA0 3VA5125-6ED41-0AA0<br />

30 3VA5130-4ED41-0AA0 3VA5130-5ED41-0AA0 3VA5130-6ED41-0AA0<br />

35 3VA5135-4ED41-0AA0 3VA5135-5ED41-0AA0 3VA5135-6ED41-0AA0<br />

40 3VA5140-4ED41-0AA0 3VA5140-5ED41-0AA0 3VA5140-6ED41-0AA0<br />

45 3VA5145-4ED41-0AA0 3VA5145-5ED41-0AA0 3VA5145-6ED41-0AA0<br />

50 3VA5150-4ED41-0AA0 3VA5150-5ED41-0AA0 3VA5150-6ED41-0AA0<br />

60 3VA5160-4ED41-0AA0 3VA5160-5ED41-0AA0 3VA5160-6ED41-0AA0<br />

70 3VA5170-4ED41-0AA0 3VA5170-5ED41-0AA0 3VA5170-6ED41-0AA0<br />

80 3VA5180-4ED41-0AA0 3VA5180-5ED41-0AA0 3VA5180-6ED41-0AA0<br />

90 3VA5190-4ED41-0AA0 3VA5190-5ED41-0AA0 3VA5190-6ED41-0AA0<br />

100 3VA5110-4ED41-0AA0 3VA5110-5ED41-0AA0 3VA5110-6ED41-0AA0<br />

110 3VA5111-4ED41-0AA0 3VA5111-5ED41-0AA0 3VA5111-6ED41-0AA0<br />

125 3VA5112-4ED41-0AA0 3VA5112-5ED41-0AA0 3VA5112-6ED41-0AA0<br />

TM210 FTFM 100% Neutral<br />

90 3VA5190-4GD41-0AA0 3VA5190-5GD41-0AA0 3VA5190-6GD41-0AA0<br />

100 3VA5110-4GD41-0AA0 3VA5110-5GD41-0AA0 3VA5110-6GD41-0AA0<br />

110 3VA5111-4GD41-0AA0 3VA5111-5GD41-0AA0 3VA5111-6GD41-0AA0<br />

125 3VA5112-4GD41-0AA0 3VA5112-5GD41-0AA0 3VA5112-6GD41-0AA0<br />

TM230 FTAM Unprotected Neutral<br />

15 3VA5195-4EC41-0AA0 3VA5195-5EC41-0AA0 3VA5195-6EC41-0AA0<br />

20 3VA5120-4EC41-0AA0 3VA5120-5EC41-0AA0 3VA5120-6EC41-0AA0<br />

25 3VA5125-4EC41-0AA0 3VA5125-5EC41-0AA0 3VA5125-6EC41-0AA0<br />

30 3VA5130-4EC41-0AA0 3VA5130-5EC41-0AA0 3VA5130-6EC41-0AA0<br />

35 3VA5135-4EC41-0AA0 3VA5135-5EC41-0AA0 3VA5135-6EC41-0AA0<br />

40 3VA5140-4EC41-0AA0 3VA5140-5EC41-0AA0 3VA5140-6EC41-0AA0<br />

45 3VA5145-4EC41-0AA0 3VA5145-5EC41-0AA0 3VA5145-6EC41-0AA0<br />

50 3VA5150-4EC41-0AA0 3VA5150-5EC41-0AA0 3VA5150-6EC41-0AA0<br />

60 3VA5160-4EC41-0AA0 3VA5160-5EC41-0AA0 3VA5160-6EC41-0AA0<br />

70 3VA5170-4EC41-0AA0 3VA5170-5EC41-0AA0 3VA5170-6EC41-0AA0<br />

80 3VA5180-4EC41-0AA0 3VA5180-5EC41-0AA0 3VA5180-6EC41-0AA0<br />

90 3VA5190-4EC41-0AA0 3VA5190-5EC41-0AA0 3VA5190-6EC41-0AA0<br />

100 3VA5110-4EC41-0AA0 3VA5110-5EC41-0AA0 3VA5110-6EC41-0AA0<br />

110 3VA5111-4EC41-0AA0 3VA5111-5EC41-0AA0 3VA5111-6EC41-0AA0<br />

125 3VA5112-4EC41-0AA0 3VA5112-5EC41-0AA0 3VA5112-6EC41-0AA0<br />

TM230 FTFM 100% Neutral<br />

90 3VA5190-4GC41-0AA0 3VA5190-5GC41-0AA0 3VA5190-6GC41-0AA0<br />

100 3VA5110-4GC41-0AA0 3VA5110-5GC41-0AA0 3VA5110-6GC41-0AA0<br />

110 3VA5111-4GC41-0AA0 3VA5111-5GC41-0AA0 3VA5111-6GC41-0AA0<br />

125 3VA5112-4GC41-0AA0 3VA5112-5GC41-0AA0 3VA5112-6GC41-0AA0<br />

TM240 ATAM Unprotected Neutral<br />

15 3VA5195-4EF41-0AA0 3VA5195-5EF41-0AA0 3VA5195-6EF41-0AA0<br />

20 3VA5120-4EF41-0AA0 3VA5120-5EF41-0AA0 3VA5120-6EF41-0AA0<br />

30 3VA5130-4EF41-0AA0 3VA5130-5EF41-0AA0 3VA5130-6EF41-0AA0<br />

40 3VA5140-4EF41-0AA0 3VA5140-5EF41-0AA0 3VA5140-6EF41-0AA0<br />

50 3VA5150-4EF41-0AA0 3VA5150-5EF41-0AA0 3VA5150-6EF41-0AA0<br />

60 3VA5160-4EF41-0AA0 3VA5160-5EF41-0AA0 3VA5160-6EF41-0AA0<br />

70 3VA5170-4EF41-0AA0 3VA5170-5EF41-0AA0 3VA5170-6EF41-0AA0<br />

80 3VA5180-4EF41-0AA0 3VA5180-5EF41-0AA0 3VA5180-6EF41-0AA0<br />

100 3VA5110-4EF41-0AA0 3VA5110-5EF41-0AA0 3VA5110-6EF41-0AA0<br />

TM240 ATAM 100% Neutral<br />

100 3VA5110-4GF41-0AA0 3VA5110-5GF41-0AA0 3VA5110-6GF41-0AA0<br />

3VA51 125A 4-Pole<br />

Ordering Information<br />

The catalog numbers listed here are<br />

for complete, non-interchangable trip<br />

circuit breakers without lugs.<br />

Order required lugs or connection<br />

technology separately for field<br />

installation.<br />

All 3VA51 thermal-magnetic trip<br />

circuit breakers are UL listed for<br />

reverse feed applications.<br />

For NAVAL-rated thermal-magnetic<br />

trip circuit breakers, change the 13th<br />

digit of the catalog number to the<br />

number "1". (For example, a 35KA<br />

@480VAC, 40A, 3-pole, NAVAL rated<br />

3VA51 would be catalog number<br />

3VA5140-5ED31-1AA0)<br />

7-50<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA51 125A Thermal-magnetic Trip Circuit Breakers<br />

Revised on 04/30/20<br />

Technical information<br />

Trip Settings for 3VA51<br />

TM210 - FTFM TM230 - FTAM TM240 - ATAM<br />

I n (A) I r (A) I i (A) I n (A) I r (A) I i (A) I n (A) I r (A) I i (A)<br />

15 15 300 15 15 150 180 210 240 270 300 15 12 150 180 210 240 270 300<br />

20 20 300 20 20 150 180 210 240 270 300 20 16 150 180 210 240 270 300<br />

25 25 300 25 25 150 180 210 240 270 300 30 24 150 180 210 240 270 300<br />

30 30 300 30 30 150 180 210 240 270 300 40 32 200 240 280 320 360 400<br />

35 35 350 35 35 175 210 245 280 315 350 50 40 250 300 350 400 450 500<br />

40 40 400 40 40 200 240 280 320 360 400 60 48 300 360 420 480 540 600<br />

45 45 450 45 45 225 270 315 360 405 450 70 56 350 420 490 560 630 700<br />

50 50 500 50 50 250 300 350 400 450 500 80 64 400 480 560 640 720 800<br />

60 60 600 60 60 300 360 420 480 540 600 100 80 500 600 700 800 900 1000<br />

70 70 700 70 70 350 420 490 560 630 700<br />

80 80 800 80 80 400 480 560 640 720 3VA 800UL Molded Case Circuit Breakers<br />

90 90 900 90 90 450 540 630 720 810 Accessories 900 and Spare Parts<br />

100 100 1000 100 100 500 600 700 800 900 1000<br />

110 110 1100 110 110 550 660 770 880 990 Internal 1100 accessories<br />

125 125 1250 125 125 625 750 875 1000 1125 1250<br />

Design<br />

Connectors for 75C Wire for 3VA51<br />

Type<br />

Steel wrap around (Cu<br />

cable only), 1 cable lugs<br />

Aluminum body lug small<br />

(Cu/Al cable), 1 cable lug<br />

Aluminum body lug (Cu/Al<br />

cable), 1 cable lugs<br />

Aluminum body lug small<br />

with control wire tap (Cu/Al<br />

cable), 1 cable lug<br />

Aluminum body lug with<br />

control wire tap (Cu/Al<br />

cable), 1 cable lugs<br />

Aluminum body lug large (Cu/<br />

Al cable), 1 cable lugs with 1<br />

extended terminal cover<br />

Aluminum body lug large<br />

with control wire tap (Cu/Al<br />

cable), 1 cable lug and<br />

1 extended terminal cover<br />

Distribution lug, 6 cables (Cu/<br />

Al cable), 1 cable lugs with<br />

1 extended terminal cover<br />

Copper body lug small (Cu<br />

cable only), 1 cable lugs<br />

Copper body lug (Cu cable<br />

only), 1 cable lugs<br />

Copper body lug small with<br />

control wire tap (Cu cable<br />

only), 1 cable lugs<br />

Copper body lug with<br />

control wire tap (Cu cable<br />

only), 1 cable lugs<br />

Min.<br />

cable<br />

size<br />

AWG<br />

14<br />

AWG<br />

14<br />

AWG<br />

14<br />

AWG<br />

14<br />

AWG<br />

14<br />

AWG<br />

4<br />

AWG<br />

4<br />

AWG<br />

14<br />

AWG<br />

14<br />

AWG<br />

14<br />

AWG<br />

14<br />

AWG<br />

14<br />

Max.<br />

cable<br />

size<br />

Catalog No.<br />

(kit of 3 lugs)<br />

Catalog No.<br />

(kit of 4 lugs)<br />

3/0 3VA9133-0JA11 3VA9134-0JA11<br />

AWG<br />

10<br />

3VA9133-0JB10<br />

3VA9134-0JB10<br />

3/0 3VA9133-0JB11 3VA9134-0JB11<br />

AWG<br />

10<br />

3VA9133-0JG10<br />

3VA9134-0JG10<br />

3/0 3VA9133-0JG11 3VA9134-0JG11<br />

300<br />

kcmil<br />

300<br />

kcmil<br />

AWG<br />

2<br />

AWG<br />

10<br />

3VA9133-0JJ12<br />

3VA9133-0JC12<br />

3VA9133-0JF60<br />

3VA9133-0JD10<br />

3VA9134-0JJ12<br />

3VA9134-0JF60<br />

3VA9134-0JD10<br />

2/0 3VA9133-0JD11 3VA9134-0JD11<br />

AWG<br />

10<br />

3VA9133-0JK10<br />

4<br />

3VA9134-0JK10<br />

2/0 3VA9133-0JK11 3VA9134-0JK11<br />

Internal accessories configuration<br />

Auxiliary switch<br />

Auxiliary switch<br />

Leading<br />

changeover switch<br />

Alarm switch<br />

Trip alarm switch<br />

Short circuit alarm switch<br />

Auxiliary release<br />

Shunt trip flexible<br />

Shunt trip left<br />

Residual current release<br />

Undervoltage release<br />

Universal release<br />

Other<br />

Cylinder lock (type Ronis)<br />

Slot No.:<br />

Type<br />

AUX_HQ x x x<br />

AUX_HQ_el x x x<br />

x<br />

AUX_HP<br />

x<br />

LCS_HQ<br />

LCS_HQ_el<br />

LCS_HP<br />

Type<br />

Type<br />

STF<br />

STL<br />

STL_el<br />

3VA4/3VA5<br />

125 A<br />

1 in 2-pole<br />

/2-pole<br />

23 22 21<br />

TAS_HQ x x<br />

TAS_HQ_el x x<br />

TAS_HP<br />

x<br />

SAS_HQ<br />

SAS_HQ_el<br />

RCR<br />

UVR<br />

UNI<br />

x<br />

x<br />

x<br />

x<br />

125 A<br />

3VA5<br />

125 A<br />

3 & 4-pole<br />

23 22 21 11 12 13<br />

x x x x x x<br />

x x x x x x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x x x x<br />

x x x x<br />

x x<br />

x<br />

x<br />

x<br />

x<br />

125 A<br />

x<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-51


3VA Molded Case Circuit Breakers<br />

3VA61 150A Electronic Trip Circuit Breakers<br />

Revised on 01/31/20<br />

Selection<br />

Ordering Information<br />

3VA61 150A 3-Pole<br />

The catalog numbers listed below are for complete, non-interchangable<br />

trip circuit breakers without lugs.<br />

Order required lugs or connection technology separately for field installation.<br />

All 3VA61 electronict trip circuit breakers are UL listed for reverse feed applications.<br />

All 3VA61 electronic trip circuit breakers are available with 100% ratings.<br />

For 100% rated electronic trip circuit breakers, change the 13th digit of the<br />

catalog number to the number "2". (For example, a 35KA @480VAC, 40A,<br />

3-pole, 100% rated 3VA61 would be catalog number 3VA6140-5HL31-2AA0)<br />

Requires the use of rated lugs — see lug table below.<br />

All 3VA6 circuit breakers are certified to UL 489 Supplement SB, are marked<br />

“Naval”, and are suitable for use at 50C.<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

3VA61 150A Frame 3-Pole Electronic Trip Unit<br />

Continuous<br />

Ampere<br />

M-Interrupting Class<br />

(MDAE)<br />

H-Interrupting Class<br />

(HDAE)<br />

C-Interrupting Class<br />

(CDAE)<br />

L-Interrupting Class<br />

(LDAE)<br />

E-Interrupting Class<br />

(EDAE)<br />

Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number<br />

ETU320 LI with dials<br />

40 3VA6140-5HL31-0AA0 3VA6140-6HL31-0AA0 3VA6140-7HL31-0AA0 3VA6140-8HL31-0AA0 3VA6160-0HL31-0AA0 a<br />

100 3VA6110-5HL31-0AA0 3VA6110-6HL31-0AA0 3VA6110-7HL31-0AA0 3VA6110-8HL31-0AA0 3VA6110-0HL31-0AA0<br />

150 3VA6115-5HL31-0AA0 3VA6115-6HL31-0AA0 3VA6115-7HL31-0AA0 3VA6115-8HL31-0AA0 3VA6115-0HL31-0AA0<br />

ETU330 LIG with dials<br />

40 3VA6140-5HM31-0AA0 3VA6140-6HM31-0AA0 3VA6140-7HM31-0AA0 3VA6140-8HM31-0AA0 3VA6160-0HM31-0AA0 a<br />

100 3VA6110-5HM31-0AA0 3VA6110-6HM31-0AA0 3VA6110-7HM31-0AA0 3VA6110-8HM31-0AA0 3VA6110-0HM31-0AA0<br />

150 3VA6115-5HM31-0AA0 3VA6115-6HM31-0AA0 3VA6115-7HM31-0AA0 3VA6115-8HM31-0AA0 3VA6115-0HM31-0AA0<br />

ETU350 LSI with dials<br />

40 3VA6140-5HN31-0AA0 3VA6140-6HN31-0AA0 3VA6140-7HN31-0AA0 3VA6140-8HN31-0AA0 3VA6160-0HN31-0AA0 a<br />

100 3VA6110-5HN31-0AA0 3VA6110-6HN31-0AA0 3VA6110-7HN31-0AA0 3VA6110-8HN31-0AA0 3VA6110-0HN31-0AA0<br />

150 3VA6115-5HN31-0AA0 3VA6115-6HN31-0AA0 3VA6115-7HN31-0AA0 3VA6115-8HN31-0AA0 3VA6115-0HN31-0AA0<br />

ETU550 LSI with LCD<br />

40 3VA6140-5JP31-0AA0 3VA6140-6JP31-0AA0 3VA6140-7JP31-0AA0 3VA6140-8JP31-0AA0 —<br />

100 3VA6110-5JP31-0AA0 3VA6110-6JP31-0AA0 3VA6110-7JP31-0AA0 3VA6110-8JP31-0AA0 —<br />

150 3VA6115-5JP31-0AA0 3VA6115-6JP31-0AA0 3VA6115-7JP31-0AA0 3VA6115-8JP31-0AA0 —<br />

ETU556 LSI(G Alarm) with LCD<br />

40 3VA6140-5JT31-0AA0 3VA6140-6JT31-0AA0 3VA6140-7JT31-0AA0 3VA6140-8JT31-0AA0 —<br />

100 3VA6110-5JT31-0AA0 3VA6110-6JT31-0AA0 3VA6110-7JT31-0AA0 3VA6110-8JT31-0AA0 —<br />

150 3VA6115-5JT31-0AA0 3VA6115-6JT31-0AA0 3VA6115-7JT31-0AA0 3VA6115-8JT31-0AA0 —<br />

ETU560 LSIG with LCD<br />

40 3VA6140-5JQ31-0AA0 3VA6140-6JQ31-0AA0 3VA6140-7JQ31-0AA0 3VA6140-8JQ31-0AA0 —<br />

100 3VA6110-5JQ31-0AA0 3VA6110-6JQ31-0AA0 3VA6110-7JQ31-0AA0 3VA6110-8JQ31-0AA0 —<br />

150 3VA6115-5JQ31-0AA0 3VA6115-6JQ31-0AA0 3VA6115-7JQ31-0AA0 3VA6115-8JQ31-0AA0 —<br />

ETU820 LI LCD with Metering<br />

40 3VA6140-5KL31-0AA0 3VA6140-6KL31-0AA0 3VA6140-7KL31-0AA0 3VA6140-8KL31-0AA0 —<br />

100 3VA6110-5KL31-0AA0 3VA6110-6KL31-0AA0 3VA6110-7KL31-0AA0 3VA6110-8KL31-0AA0 —<br />

150 3VA6115-5KL31-0AA0 3VA6115-6KL31-0AA0 3VA6115-7KL31-0AA0 3VA6115-8KL31-0AA0 —<br />

ETU830 LIG with LCD and Metering<br />

40 3VA6140-5KM31-0AA0 3VA6140-6KM31-0AA0 3VA6140-7KM31-0AA0 3VA6140-8KM31-0AA0 —<br />

100 3VA6110-5KM31-0AA0 3VA6110-6KM31-0AA0 3VA6110-7KM31-0AA0 3VA6110-8KM31-0AA0 —<br />

150 3VA6115-5KM31-0AA0 3VA6115-6KM31-0AA0 3VA6115-7KM31-0AA0 3VA6115-8KM31-0AA0 —<br />

ETU850 LSI with LCD and Metering<br />

40 3VA6140-5KP31-0AA0 3VA6140-6KP31-0AA0 3VA6140-7KP31-0AA0 3VA6140-8KP31-0AA0 —<br />

100 3VA6110-5KP31-0AA0 3VA6110-6KP31-0AA0 3VA6110-7KP31-0AA0 3VA6110-8KP31-0AA0 —<br />

150 3VA6115-5KP31-0AA0 3VA6115-6KP31-0AA0 3VA6115-7KP31-0AA0 3VA6115-8KP31-0AA0 —<br />

ETU856 LSI(G Alarm) with LCD and Metering<br />

40 3VA6140-5KT31-0AA0 3VA6140-6KT31-0AA0 3VA6140-7KT31-0AA0 3VA6140-8KT31-0AA0 3VA6160-0KT31-0AA0 a<br />

100 3VA6110-5KT31-0AA0 3VA6110-6KT31-0AA0 3VA6110-7KT31-0AA0 3VA6110-8KT31-0AA0 3VA6110-0KT31-0AA0<br />

150 3VA6115-5KT31-0AA0 3VA6115-6KT31-0AA0 3VA6115-7KT31-0AA0 3VA6115-8KT31-0AA0 3VA6115-0KT31-0AA0<br />

ETU860 LSIG with LCD and Metering<br />

40 3VA6140-5KQ31-0AA0 3VA6140-6KQ31-0AA0 3VA6140-7KQ31-0AA0 3VA6140-8KQ31-0AA0 3VA6160-0KQ31-0AA0 a<br />

100 3VA6110-5KQ31-0AA0 3VA6110-6KQ31-0AA0 3VA6110-7KQ31-0AA0 3VA6110-8KQ31-0AA0 3VA6110-0KQ31-0AA0<br />

150 3VA6115-5KQ31-0AA0 3VA6115-6KQ31-0AA0 3VA6115-7KQ31-0AA0 3VA6115-8KQ31-0AA0 3VA6115-0KQ31-0AA0<br />

a The lowest amperage trip unit available for the EDAE class breakers is 60 amps.<br />

7-52<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA61 150A Electronic Trip Circuit Breakers<br />

Revised on 01/31/20<br />

Selection<br />

Ordering Information<br />

The catalog numbers listed below are for complete, non-interchangable<br />

trip circuit breakers without lugs.<br />

Order required lugs or connection technology separately for field installation.<br />

All 3VA61 electronic trip circuit breakers are UL listed for reverse feed applications.<br />

All 3VA61 electronic trip circuit breakers are available with 100% ratings.<br />

For 100% rated electronic trip circuit breakers, change the 13th digit of the<br />

catalog number to the number "2". (For example, a 35KA @480VAC, 40A,<br />

3-pole, 100% rated 3VA61 would be catalog number 3VA6140-5HL31-2AA0)<br />

Requires the use of rated lugs — see lug table below.<br />

3VA61 150A 4-Pole<br />

All 3VA6 circuit breakers are certified to UL 489 Supplement SB, are marked<br />

“Naval”, and are suitable for use at 50C.<br />

3VA61 150A Frame 4-Pole Electronic Trip Unit<br />

Continuous<br />

Ampere<br />

M-Interrupting Class<br />

(MDAE)<br />

H-Interrupting Class<br />

(HDAE)<br />

C-Interrupting Class<br />

(CDAE)<br />

L-Interrupting Class<br />

(LDAE)<br />

E-Interrupting Class<br />

(EDAE)<br />

Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number<br />

ETU320 LI with dials<br />

40 3VA6140-5HL41-0AA0 3VA6140-6HL41-0AA0 3VA6140-7HL41-0AA0 3VA6140-8HL41-0AA0 3VA6160-0HL41-0AA0 a<br />

100 3VA6110-5HL41-0AA0 3VA6110-6HL41-0AA0 3VA6110-7HL41-0AA0 3VA6110-8HL41-0AA0 3VA6110-0HL41-0AA0<br />

150 3VA6115-5HL41-0AA0 3VA6115-6HL41-0AA0 3VA6115-7HL41-0AA0 3VA6115-8HL41-0AA0 3VA6115-0HL41-0AA0<br />

ETU330 LIG with dials<br />

40 3VA6140-5HM41-0AA0 3VA6140-6HM41-0AA0 3VA6140-7HM41-0AA0 3VA6140-8HM41-0AA0 3VA6160-0HM41-0AA0 a<br />

100 3VA6110-5HM41-0AA0 3VA6110-6HM41-0AA0 3VA6110-7HM41-0AA0 3VA6110-8HM41-0AA0 3VA6110-0HM41-0AA0<br />

150 3VA6115-5HM41-0AA0 3VA6115-6HM41-0AA0 3VA6115-7HM41-0AA0 3VA6115-8HM41-0AA0 3VA6115-0HM41-0AA0<br />

ETU350 LSI with dials<br />

40 3VA6140-5HN41-0AA0 3VA6140-6HN41-0AA0 3VA6140-7HN41-0AA0 3VA6140-8HN41-0AA0 3VA6160-0HN41-0AA0 a<br />

100 3VA6110-5HN41-0AA0 3VA6110-6HN41-0AA0 3VA6110-7HN41-0AA0 3VA6110-8HN41-0AA0 3VA6110-0HN41-0AA0<br />

150 3VA6115-5HN41-0AA0 3VA6115-6HN41-0AA0 3VA6115-7HN41-0AA0 3VA6115-8HN41-0AA0 3VA6115-0HN41-0AA0<br />

ETU550 LSI with LCD<br />

40 3VA6140-5JP41-0AA0 3VA6140-6JP41-0AA0 3VA6140-7JP41-0AA0 3VA6140-8JP41-0AA0 —<br />

100 3VA6110-5JP41-0AA0 3VA6110-6JP41-0AA0 3VA6110-7JP41-0AA0 3VA6110-8JP41-0AA0 —<br />

150 3VA6115-5JP41-0AA0 3VA6115-6JP41-0AA0 3VA6115-7JP41-0AA0 3VA6115-8JP41-0AA0 —<br />

ETU556 LSI(G Alarm) with LCD<br />

40 3VA6140-5JT41-0AA0 3VA6140-6JT41-0AA0 3VA6140-7JT41-0AA0 3VA6140-8JT41-0AA0 —<br />

100 3VA6110-5JT41-0AA0 3VA6110-6JT41-0AA0 3VA6110-7JT41-0AA0 3VA6110-8JT41-0AA0 —<br />

150 3VA6115-5JT41-0AA0 3VA6115-6JT41-0AA0 3VA6115-7JT41-0AA0 3VA6115-8JT41-0AA0 —<br />

ETU560 LSIG with LCD<br />

40 3VA6140-5JQ41-0AA0 3VA6140-6JQ41-0AA0 3VA6140-7JQ41-0AA0 3VA6140-8JQ41-0AA0 —<br />

100 3VA6110-5JQ41-0AA0 3VA6110-6JQ41-0AA0 3VA6110-7JQ41-0AA0 3VA6110-8JQ41-0AA0 —<br />

150 3VA6115-5JQ41-0AA0 3VA6115-6JQ41-0AA0 3VA6115-7JQ41-0AA0 3VA6115-8JQ41-0AA0 —<br />

ETU820 LI LCD with Metering<br />

40 3VA6140-5KL41-0AA0 3VA6140-6KL41-0AA0 3VA6140-7KL41-0AA0 3VA6140-8KL41-0AA0 —<br />

100 3VA6110-5KL41-0AA0 3VA6110-6KL41-0AA0 3VA6110-7KL41-0AA0 3VA6110-8KL41-0AA0 —<br />

150 3VA6115-5KL41-0AA0 3VA6115-6KL41-0AA0 3VA6115-7KL41-0AA0 3VA6115-8KL41-0AA0 —<br />

ETU830 LIG with LCD and Metering<br />

40 3VA6140-5KM41-0AA0 3VA6140-6KM41-0AA0 3VA6140-7KM41-0AA0 3VA6140-8KM41-0AA0 —<br />

100 3VA6110-5KM41-0AA0 3VA6110-6KM41-0AA0 3VA6110-7KM41-0AA0 3VA6110-8KM41-0AA0 —<br />

150 3VA6115-5KM41-0AA0 3VA6115-6KM41-0AA0 3VA6115-7KM41-0AA0 3VA6115-8KM41-0AA0 —<br />

ETU850 LSI with LCD and Metering<br />

40 3VA6140-5KP41-0AA0 3VA6140-6KP41-0AA0 3VA6140-7KP41-0AA0 3VA6140-8KP41-0AA0 —<br />

100 3VA6110-5KP41-0AA0 3VA6110-6KP41-0AA0 3VA6110-7KP41-0AA0 3VA6110-8KP41-0AA0 —<br />

150 3VA6115-5KP41-0AA0 3VA6115-6KP41-0AA0 3VA6115-7KP41-0AA0 3VA6115-8KP41-0AA0 —<br />

ETU856 LSI(G Alarm) with LCD and Metering<br />

40 3VA6140-5KT41-0AA0 3VA6140-6KT41-0AA0 3VA6140-7KT41-0AA0 3VA6140-8KT41-0AA0 3VA6160-0KT41-0AA0 a<br />

100 3VA6110-5KT41-0AA0 3VA6110-6KT41-0AA0 3VA6110-7KT41-0AA0 3VA6110-8KT41-0AA0 3VA6110-0KT41-0AA0<br />

150 3VA6115-5KT41-0AA0 3VA6115-6KT41-0AA0 3VA6115-7KT41-0AA0 3VA6115-8KT41-0AA0 3VA6115-0KT41-0AA0<br />

ETU860 LSIG with LCD and Metering<br />

40 3VA6140-5KQ41-0AA0 3VA6140-6KQ41-0AA0 3VA6140-7KQ41-0AA0 3VA6140-8KQ41-0AA0 3VA6160-0KQ41-0AA0 a<br />

100 3VA6110-5KQ41-0AA0 3VA6110-6KQ41-0AA0 3VA6110-7KQ41-0AA0 3VA6110-8KQ41-0AA0 3VA6110-0KQ41-0AA0<br />

150 3VA6115-5KQ41-0AA0 3VA6115-6KQ41-0AA0 3VA6115-7KQ41-0AA0 3VA6115-8KQ41-0AA0 3VA6115-0KQ41-0AA0<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

a The lowest amperage trip unit available for the EDAE class breakers is 60 amps.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-53


3VA Molded Case Circuit Breakers<br />

3VA61 150A Electronic Trip Circuit Breakers<br />

Revised on 04/30/20<br />

Technical information<br />

Connectors for 75C wire for 3VA61<br />

Type<br />

Minimum<br />

cable size<br />

Maximum<br />

cable size<br />

Part Number<br />

(kit of 3 lugs)<br />

Part Number<br />

(kit of 4 lugs)<br />

Steel Wrap around (Cu cable only)<br />

AWG 10 3/0 3VA9143-0JA12 3VA9144-0JA12<br />

single cable lugs b AWG 4 350 kcmil 3VA9243-0JA12 3VA9244-0JA12<br />

Aluminum Body Lug (Cu/Al cable)<br />

AWG 14 1/0 3VA9143-0JB11 3VA9144-0JB11<br />

single cable lugs a AWG 6 350 kcmil 3VA9243-0JB12 3VA9244-0JB12<br />

Aluminum body lug with control wire tap<br />

AWG 14 1/0 3VA9143-0JG11 c 3VA9144-0JG11 c<br />

(Cu/Al cable) single cable lugs a AWG 6 350 kcmil 3VA9243-0JG12 3VA9244-0JG12<br />

Aluminum body lug large (Cu/Al cable)<br />

single cable lugs and 1 ext’d terminal cover a AWG 2 350 kcmil 3VA9243-0JJ13 3VA9244-0JJ13<br />

Aluminum body lug large with control wire tap<br />

(Cu/Al cable) single cable lugs and<br />

AWG 2 350 kcmil 3VA9243-0JC13 3VA9244-0JC13<br />

1 extended terminal cover a<br />

Aluminum body lug, 2 cables (Cu/Al cable) with<br />

1 extended terminal cover a AWG 4 300 kcmil 3VA9243-0JJ22 3VA9244-0JJ22<br />

Aluminum body lug, 2 cables (Cu/Al cable)<br />

with control wire tap and 1 extended terminal cover a AWG 4 300 kcmil 3VA9243-0JC22 3VA9244-0JC22<br />

Distribution lug, 6 Cables (Cu/Al cable) with<br />

1 extended terminal cover b AWG 14 AWG 2 3VA9243-0JF60 3VA9244-0JF60<br />

Copper body lug (Cu cable only) single cable lugs<br />

AWG 14 1/0 3VA9143-0JD11 3VA9144-0JD11<br />

kit of 3 single lugs a AWG 6 350 kcmil 3VA9243-0JD12 3VA9244-0JD12<br />

Copper body lug (Cu cable only) with control<br />

AWG 14 1/0 3VA9143-0JK11 c 3VA9144-0JK11 c<br />

wire tap single cable lugs a AWG 6 350 kcmil 3VA9243-0JK12 3VA9244-0JK12<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Interrupting Ratings for 3VA61<br />

Interrupting<br />

Class<br />

Dimensions<br />

Breaker<br />

Type<br />

RMS Symmetrical Amperes (kA)<br />

Volts AC (50/60 Hz)<br />

240 480Y/277V 480 600Y/347V 600<br />

M MDAE 100 35 35 18 18<br />

H HDAE 100 65 65 22 22<br />

C CDAE 200 100 100 35 35<br />

L LDAE 200 150 150 50 50<br />

E EDAE — 200 200 100 100<br />

Shipping Weight<br />

Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg<br />

3VA61 3 4.1 (105) 7.8 (198) 3.4 (86) 5.5 2.5<br />

3VA61 4 5.5 (140) 7.8 (198) 3.4 (86) 7.1 3.2<br />

Enclosures (3-pole only)<br />

Nema Type<br />

Catalog Number<br />

1 surface 3VAE250N1S<br />

1 flush 3VAE250N1F<br />

3R<br />

3VAE250N3R<br />

12 3VAE250N12<br />

4X (304)<br />

3VAE250N4X<br />

4X (316)<br />

3VAE250N4X316<br />

Neutral<br />

N250X<br />

200% Neutral N2250X<br />

a Meets requirements for 100% rated breakers up to 150A.<br />

b Meets requirements for 100% rated breakers up to 100A.<br />

c Limited to 150A including the control wire tap.<br />

7-54<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA61 150A Electronic Trip Circuit Breakers<br />

Revised on 09/30/19<br />

Technical information<br />

Trip Settings for 3VA61<br />

ETU320-LI, ETU330-LIG, ETU350-LSI<br />

Continuous<br />

Amperage LI, LIG, LSI LSI LIG<br />

LI, LIG, LSI<br />

4P only<br />

I n (Amp) I r(Amp) (L) t ld (sec) (L) I i (Amp) (I) a (Amp) (S) t sd (sec) (S) I g (Amp) (G) I N=xI r (Amp)<br />

I sd= xIr<br />

40 15 - 40 0.5 - 17 60-480 1.5 - 10 0.08 - 0.4 15 - 40 1 / OFF<br />

100 40 - 100 0.5 - 17 150-1200 1.5 - 10 20 - 100 0.5 - 1 / OFF<br />

150 60 - 150 0.5 - 17 225-1500 1.5 - 10 30 - 150 0.5 - 1 / OFF<br />

a I i for ETU350 is fixed at the maximum level shown in table.<br />

ETU550-LSI, ETU556 LSI(A), ETU560-LSIG, ETU820-LI, ETU830-LIG, ETU850-LSI, ETU856 LSI(A), ETU860-LSIG<br />

Continuous<br />

Amperage LI, LIG, LSI, LSIG, LSI(G) LSI, LSIG, LSI(G) LIG, LSIG, LSI(G)<br />

LSI 3P with<br />

External CT<br />

LI, LIG, LSI, LSIG,<br />

LSI(G) 4P only<br />

I n (Amp) I r(Amp) (L) t ld (sec) (L) I i (Amp) (I) I sd (Amp) (S) t sd (sec) (S) I g (Amp) (G) t g (G) I N=xI r (Amp) I N (Amp)<br />

40 15 - 40 0.5 - 25 60-480 24 - 400 0.05 - 0.5 15 - 40 0.05 - 0.8 15 - 64 / OFF 15 - 64 / OFF<br />

100 40 - 100 0.5 - 25 150-1200 60 - 1000 20 - 100 20 - 160 / OFF 20 - 150 / OFF<br />

150 60 - 150 0.5 - 20 225-1500 90 - 1500 30 - 150 30 - 240 / OFF 30 - 150 / OFF<br />

For specific trip settings refer to the Electronic Trip Unit section 3VA of the UL 3VA Molded Systems Case Manual, Circuit Breakers<br />

which can be found in the document download center at https://www.siemens.com/download?BTLV_50412.<br />

Accessories and Spare Parts<br />

Internal accessories<br />

Internal accessories<br />

Optional equipment<br />

3VA6<br />

3VA6<br />

150/250 A 150/250 A<br />

3-pole<br />

4-pole<br />

250 A 250 A<br />

Auxiliary switch<br />

Auxiliary switch<br />

Leading changeover switch<br />

Alarm switch<br />

Trip alarm switch<br />

Electrical alarm switch<br />

Auxiliary release<br />

Slot No.:<br />

Type<br />

Type<br />

Type<br />

24 23 22 21 11 12 13 14 34 33 32 31 24 23 22 21 11 12 13 14<br />

AUX_HQ x x x x x x x x x x x x x x x x x x x x<br />

AUX_HQ_el x x x x x x x x x x x x x x x x x x x x<br />

AUX_HP x x x x x x x x x x<br />

x x x x x<br />

LCS_HQ x x<br />

LCS_HQ_el x x<br />

LCS_HP x x<br />

TAS_HQ x x x x x x x x<br />

TAS_HQ_el x x x x x x x x<br />

TAS_HP x x x x<br />

EAS_HQ x x<br />

EAS_HQ_el x x<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Shunt trip flexible<br />

STF x x x x<br />

Shunt trip left<br />

Undervoltage release<br />

STL x x<br />

UVR x x<br />

4<br />

Universal release<br />

UNI x x<br />

ETU/communication<br />

Type<br />

Communication module<br />

Breaker data server<br />

COM060<br />

x<br />

x<br />

24 V module<br />

x<br />

x<br />

Other<br />

Cylinder lock (type Ronis)<br />

x<br />

x<br />

I201_19495<br />

See page 7-81 for internal accessory<br />

part numbers.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-55


3VA Molded Case Circuit Breakers<br />

3VA52 250A Thermal-magnetic Trip Circuit Breakers<br />

Revised on 11/30/19<br />

Selection<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

3VA52 250 A, 2-Pole in 3-Pole Frame Thermal-Magnetic Trip Unit<br />

Cont.<br />

Ampere<br />

Rating<br />

M-Interrupting Class<br />

(MFAS)<br />

H-Interrupting Class<br />

(HFAS)<br />

C-Interrupting Class<br />

(CFAS)<br />

Catalog Number Catalog Number Catalog Number<br />

TM210 FTFM<br />

40 3VA5240-5ED61-0AA0 3VA5240-6ED61-0AA0 3VA5240-7ED61-0AA0<br />

45 3VA5245-5ED61-0AA0 3VA5245-6ED61-0AA0 3VA5245-7ED61-0AA0<br />

50 3VA5250-5ED61-0AA0 3VA5250-6ED61-0AA0 3VA5250-7ED61-0AA0<br />

60 3VA5260-5ED61-0AA0 3VA5260-6ED61-0AA0 3VA5260-7ED61-0AA0<br />

70 3VA5270-5ED61-0AA0 3VA5270-6ED61-0AA0 3VA5270-7ED61-0AA0<br />

80 3VA5280-5ED61-0AA0 3VA5280-6ED61-0AA0 3VA5280-7ED61-0AA0<br />

90 3VA5290-5ED61-0AA0 3VA5290-6ED61-0AA0 3VA5290-7ED61-0AA0<br />

100 3VA5210-5ED61-0AA0 3VA5210-6ED61-0AA0 3VA5210-7ED61-0AA0<br />

110 3VA5211-5ED61-0AA0 3VA5211-6ED61-0AA0 3VA5211-7ED61-0AA0<br />

125 3VA5212-5ED61-0AA0 3VA5212-6ED61-0AA0 3VA5212-7ED61-0AA0<br />

150 3VA5215-5ED61-0AA0 3VA5215-6ED61-0AA0 3VA5215-7ED61-0AA0<br />

175 3VA5217-5ED61-0AA0 3VA5217-6ED61-0AA0 3VA5217-7ED61-0AA0<br />

200 3VA5220-5ED61-0AA0 3VA5220-6ED61-0AA0 3VA5220-7ED61-0AA0<br />

225 3VA5222-5ED61-0AA0 3VA5222-6ED61-0AA0 3VA5222-7ED61-0AA0<br />

250 3VA5225-5ED61-0AA0 3VA5225-6ED61-0AA0 3VA5225-7ED61-0AA0<br />

TM230 FTAM<br />

70 3VA5270-5EC61-0AA0 3VA5270-6EC61-0AA0 3VA5270-7EC61-0AA0<br />

80 3VA5280-5EC61-0AA0 3VA5280-6EC61-0AA0 3VA5280-7EC61-0AA0<br />

90 3VA5290-5EC61-0AA0 3VA5290-6EC61-0AA0 3VA5290-7EC61-0AA0<br />

100 3VA5210-5EC61-0AA0 3VA5210-6EC61-0AA0 3VA5210-7EC61-0AA0<br />

110 3VA5211-5EC61-0AA0 3VA5211-6EC61-0AA0 3VA5211-7EC61-0AA0<br />

125 3VA5212-5EC61-0AA0 3VA5212-6EC61-0AA0 3VA5212-7EC61-0AA0<br />

150 3VA5215-5EC61-0AA0 3VA5215-6EC61-0AA0 3VA5215-7EC61-0AA0<br />

175 3VA5217-5EC61-0AA0 3VA5217-6EC61-0AA0 3VA5217-7EC61-0AA0<br />

200 3VA5220-5EC61-0AA0 3VA5220-6EC61-0AA0 3VA5220-7EC61-0AA0<br />

225 3VA5222-5EC61-0AA0 3VA5222-6EC61-0AA0 3VA5222-7EC61-0AA0<br />

250 3VA5225-5EC61-0AA0 3VA5225-6EC61-0AA0 3VA5225-7EC61-0AA0<br />

Dimensions<br />

Shipping Weight<br />

Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg<br />

3VA52 2(3-) pole 4.1 (105) 7.3 (185) 3.3 (83) 4.1 1.9<br />

3VA52 3-pole 4.1 (105) 7.3 (185) 3.3 (83) 4.5 2.1<br />

3VA52 250A 3-Pole<br />

Ordering Information<br />

The catalog numbers listed here are<br />

for complete, non-interchangable trip<br />

circuit breakers without lugs.<br />

Order required lugs or connection<br />

technology separately for field<br />

installation.<br />

All 3VA52 thermal-magnetic trip<br />

circuit breakers are UL listed for<br />

reverse feed applications.<br />

For NAVAL rated thermal-magnetic<br />

trip circuit breakers, change the 13th<br />

digit of the catalog number to the<br />

number "1". (For example, a 35KA<br />

@480VAC, 150A, 3-pole, NAVAL<br />

rated 3VA52 would be catalog<br />

number 3VA5215-5ED31-1AA0)<br />

Enclosures (3-pole only)<br />

Nema Type<br />

Catalog Number<br />

1 surface 3VAE250N1S<br />

1 flush 3VAE250N1F<br />

3R<br />

3VAE250N3R<br />

12 3VAE250N12<br />

4X (304)<br />

3VAE250N4X<br />

4X (316)<br />

3VAE250N4X316<br />

Neutral<br />

N250X<br />

200% Neutral N2250X<br />

7-56<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA52 250A Thermal-magnetic Trip Circuit Breakers<br />

Revised on 07/31/19<br />

Selection<br />

3VA52 250 A Frame, 3-Pole Thermal-Magnetic Trip Unit<br />

Cont.<br />

Ampere<br />

Rating<br />

M-Interrupting Class<br />

(MFAS)<br />

H-Interrupting Class<br />

(HFAS)<br />

C-Interrupting Class<br />

(CFAS)<br />

Catalog Number Catalog Number Catalog Number<br />

TM210 FTFM a<br />

40 3VA5240-5ED31-0AA0 3VA5240-6ED31-0AA0 3VA5240-7ED31-0AA0<br />

45 3VA5245-5ED31-0AA0 3VA5245-6ED31-0AA0 3VA5245-7ED31-0AA0<br />

50 3VA5250-5ED31-0AA0 3VA5250-6ED31-0AA0 3VA5250-7ED31-0AA0<br />

60 3VA5260-5ED31-0AA0 3VA5260-6ED31-0AA0 3VA5260-7ED31-0AA0<br />

70 3VA5270-5ED31-0AA0 3VA5270-6ED31-0AA0 3VA5270-7ED31-0AA0<br />

80 3VA5280-5ED31-0AA0 3VA5280-6ED31-0AA0 3VA5280-7ED31-0AA0<br />

90 3VA5290-5ED31-0AA0 3VA5290-6ED31-0AA0 3VA5290-7ED31-0AA0<br />

100 3VA5210-5ED31-0AA0 3VA5210-6ED31-0AA0 3VA5210-7ED31-0AA0<br />

110 3VA5211-5ED31-0AA0 3VA5211-6ED31-0AA0 3VA5211-7ED31-0AA0<br />

125 3VA5212-5ED31-0AA0 3VA5212-6ED31-0AA0 3VA5212-7ED31-0AA0<br />

150 3VA5215-5ED31-0AA0 3VA5215-6ED31-0AA0 3VA5215-7ED31-0AA0<br />

175 3VA5217-5ED31-0AA0 3VA5217-6ED31-0AA0 3VA5217-7ED31-0AA0<br />

200 3VA5220-5ED31-0AA0 3VA5220-6ED31-0AA0 3VA5220-7ED31-0AA0<br />

225 3VA5222-5ED31-0AA0 3VA5222-6ED31-0AA0 3VA5222-7ED31-0AA0<br />

250 3VA5225-5ED31-0AA0 3VA5225-6ED31-0AA0 3VA5225-7ED31-0AA0<br />

TM230 FTAM a<br />

70 3VA5270-5EC31-0AA0 3VA5270-6EC31-0AA0 3VA5270-7EC31-0AA0<br />

80 3VA5280-5EC31-0AA0 3VA5280-6EC31-0AA0 3VA5280-7EC31-0AA0<br />

90 3VA5290-5EC31-0AA0 3VA5290-6EC31-0AA0 3VA5290-7EC31-0AA0<br />

100 3VA5210-5EC31-0AA0 3VA5210-6EC31-0AA0 3VA5210-7EC31-0AA0<br />

110 3VA5211-5EC31-0AA0 3VA5211-6EC31-0AA0 3VA5211-7EC31-0AA0<br />

125 3VA5212-5EC31-0AA0 3VA5212-6EC31-0AA0 3VA5212-7EC31-0AA0<br />

150 3VA5215-5EC31-0AA0 3VA5215-6EC31-0AA0 3VA5215-7EC31-0AA0<br />

175 3VA5217-5EC31-0AA0 3VA5217-6EC31-0AA0 3VA5217-7EC31-0AA0<br />

200 3VA5220-5EC31-0AA0 3VA5220-6EC31-0AA0 3VA5220-7EC31-0AA0<br />

225 3VA5222-5EC31-0AA0 3VA5222-6EC31-0AA0 3VA5222-7EC31-0AA0<br />

250 3VA5225-5EC31-0AA0 3VA5225-6EC31-0AA0 3VA5225-7EC31-0AA0<br />

TM240 ATAM<br />

70 3VA5270-5EF31-0AA0 3VA5270-6EF31-0AA0 3VA5270-7EF31-0AA0<br />

80 3VA5280-5EF31-0AA0 3VA5280-6EF31-0AA0 3VA5280-7EF31-0AA0<br />

100 3VA5210-5EF31-0AA0 3VA5210-6EF31-0AA0 3VA5210-7EF31-0AA0<br />

125 3VA5212-5EF31-0AA0 3VA5212-6EF31-0AA0 3VA5212-7EF31-0AA0<br />

150 3VA5215-5EF31-0AA0 3VA5215-6EF31-0AA0 3VA5215-7EF31-0AA0<br />

175 3VA5217-5EF31-0AA0 3VA5217-6EF31-0AA0 3VA5217-7EF31-0AA0<br />

200 3VA5220-5EF31-0AA0 3VA5220-6EF31-0AA0 3VA5220-7EF31-0AA0<br />

250 3VA5225-5EF31-0AA0 3VA5225-6EF31-0AA0 3VA5225-7EF31-0AA0<br />

Dimensions<br />

Shipping Weight<br />

Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg<br />

3VA52 2(3-) pole 4.1 (105) 7.3 (185) 3.3 (83) 4.1 1.9<br />

3VA52 3-pole 4.1 (105) 7.3 (185) 3.3 (83) 4.5 2.1<br />

Ordering Information<br />

The catalog numbers listed here are<br />

for complete, non-interchangable trip<br />

circuit breakers without lugs.<br />

Order required lugs or connection<br />

technology separately for field<br />

installation.<br />

All 3VA52 thermal-magnetic trip<br />

circuit breakers are UL listed for<br />

reverse feed applications.<br />

For NAVAL rated thermal-magnetic<br />

trip circuit breakers, change the 13th<br />

digit of the catalog number to the<br />

number "1". (For example, a 35KA<br />

@480VAC, 150A, 3-pole, NAVAL<br />

rated 3VA52 would be catalog<br />

number 3VA5215-5ED31-1AA0)<br />

Enclosures (3-pole only)<br />

Nema Type<br />

Catalog Number<br />

1 surface 3VAE250N1S<br />

1 flush 3VAE250N1F<br />

3R<br />

3VAE250N3R<br />

12 3VAE250N12<br />

4X (304)<br />

3VAE250N4X<br />

4X (316)<br />

3VAE250N4X316<br />

Neutral<br />

N250X<br />

200% Neutral N2250X<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

a Available with NAVAL/50C ratings.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-57


3VA Molded Case Circuit Breakers<br />

3VA52 250A Thermal-magnetic Trip Circuit Breakers<br />

Revised on 07/31/19<br />

Selection<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

3VA52 250A Frame, 4-pole Thermal-Magnetic Trip Unit<br />

Cont.<br />

Ampere<br />

Rating<br />

M-Interrupting Class<br />

(MFAS)<br />

H-Interrupting Class<br />

(HFAS)<br />

C-Interrupting Class<br />

(CFAS)<br />

Catalog Number Catalog Number Catalog Number<br />

TM210 FTFM<br />

40 3VA5240-5ED41-0AA0 3VA5240-6ED41-0AA0 3VA5240-7ED41-0AA0<br />

45 3VA5245-5ED41-0AA0 3VA5245-6ED41-0AA0 3VA5245-7ED41-0AA0<br />

50 3VA5250-5ED41-0AA0 3VA5250-6ED41-0AA0 3VA5250-7ED41-0AA0<br />

60 3VA5260-5ED41-0AA0 3VA5260-6ED41-0AA0 3VA5260-7ED41-0AA0<br />

70 3VA5270-5ED41-0AA0 3VA5270-6ED41-0AA0 3VA5270-7ED41-0AA0<br />

80 3VA5280-5ED41-0AA0 3VA5280-6ED41-0AA0 3VA5280-7ED41-0AA0<br />

90 3VA5290-5ED41-0AA0 3VA5290-6ED41-0AA0 3VA5290-7ED41-0AA0<br />

100 3VA5210-5ED41-0AA0 3VA5210-6ED41-0AA0 3VA5210-7ED41-0AA0<br />

110 3VA5211-5ED41-0AA0 3VA5211-6ED41-0AA0 3VA5211-7ED41-0AA0<br />

125 3VA5212-5ED41-0AA0 3VA5212-6ED41-0AA0 3VA5212-7ED41-0AA0<br />

150 3VA5215-5ED41-0AA0 3VA5215-6ED41-0AA0 3VA5215-7ED41-0AA0<br />

175 3VA5217-5ED41-0AA0 3VA5217-6ED41-0AA0 3VA5217-7ED41-0AA0<br />

200 3VA5220-5ED41-0AA0 3VA5220-6ED41-0AA0 3VA5220-7ED41-0AA0<br />

225 3VA5222-5ED41-0AA0 3VA5222-6ED41-0AA0 3VA5222-7ED41-0AA0<br />

250 3VA5225-5ED41-0AA0 3VA5225-6ED41-0AA0 3VA5225-7ED41-0AA0<br />

TM210 FTFM 100% Neutral<br />

90 3VA5290-5GD41-0AA0 3VA5290-6GD41-0AA0 3VA5290-7GD41-0AA0<br />

100 3VA5210-5GD41-0AA0 3VA5210-6GD41-0AA0 3VA5210-7GD41-0AA0<br />

110 3VA5211-5GD41-0AA0 3VA5211-6GD41-0AA0 3VA5211-7GD41-0AA0<br />

125 3VA5212-5GD41-0AA0 3VA5212-6GD41-0AA0 3VA5212-7GD41-0AA0<br />

150 3VA5215-5GD41-0AA0 3VA5215-6GD41-0AA0 3VA5215-7GD41-0AA0<br />

175 3VA5217-5GD41-0AA0 3VA5217-6GD41-0AA0 3VA5217-7GD41-0AA0<br />

200 3VA5220-5GD41-0AA0 3VA5220-6GD41-0AA0 3VA5220-7GD41-0AA0<br />

225 3VA5222-5GD41-0AA0 3VA5222-6GD41-0AA0 3VA5222-7GD41-0AA0<br />

250 3VA5225-5GD41-0AA0 3VA5225-6GD41-0AA0 3VA5225-7GD41-0AA0<br />

TM230 FTAM<br />

70 3VA5270-5EC41-0AA0 3VA5270-6EC41-0AA0 3VA5270-7EC41-0AA0<br />

80 3VA5280-5EC41-0AA0 3VA5280-6EC41-0AA0 3VA5280-7EC41-0AA0<br />

90 3VA5290-5EC41-0AA0 3VA5290-6EC41-0AA0 3VA5290-7EC41-0AA0<br />

100 3VA5210-5EC41-0AA0 3VA5210-6EC41-0AA0 3VA5210-7EC41-0AA0<br />

110 3VA5211-5EC41-0AA0 3VA5211-6EC41-0AA0 3VA5211-7EC41-0AA0<br />

125 3VA5212-5EC41-0AA0 3VA5212-6EC41-0AA0 3VA5212-7EC41-0AA0<br />

150 3VA5215-5EC41-0AA0 3VA5215-6EC41-0AA0 3VA5215-7EC41-0AA0<br />

175 3VA5217-5EC41-0AA0 3VA5217-6EC41-0AA0 3VA5217-7EC41-0AA0<br />

200 3VA5220-5EC41-0AA0 3VA5220-6EC41-0AA0 3VA5220-7EC41-0AA0<br />

225 3VA5222-5EC41-0AA0 3VA5222-6EC41-0AA0 3VA5222-7EC41-0AA0<br />

250 3VA5225-5EC41-0AA0 3VA5225-6EC41-0AA0 3VA5225-7EC41-0AA0<br />

TM230 FTAM 100% Neutral<br />

90 3VA5290-5GC41-0AA0 3VA5290-6GC41-0AA0 3VA5290-7GC41-0AA0<br />

100 3VA5210-5GC41-0AA0 3VA5210-6GC41-0AA0 3VA5210-7GC41-0AA0<br />

110 3VA5211-5GC41-0AA0 3VA5211-6GC41-0AA0 3VA5211-7GC41-0AA0<br />

125 3VA5212-5GC41-0AA0 3VA5212-6GC41-0AA0 3VA5212-7GC41-0AA0<br />

150 3VA5215-5GC41-0AA0 3VA5215-6GC41-0AA0 3VA5215-7GC41-0AA0<br />

175 3VA5217-5GC41-0AA0 3VA5217-6GC41-0AA0 3VA5217-7GC41-0AA0<br />

200 3VA5220-5GC41-0AA0 3VA5220-6GC41-0AA0 3VA5220-7GC41-0AA0<br />

225 3VA5222-5GC41-0AA0 3VA5222-6GC41-0AA0 3VA5222-7GC41-0AA0<br />

250 3VA5225-5GC41-0AA0 3VA5225-6GC41-0AA0 3VA5225-7GC41-0AA0<br />

TM240 ATAM<br />

70 3VA5270-5EF41-0AA0 3VA5270-6EF41-0AA0 3VA5270-7EF41-0AA0<br />

80 3VA5280-5EF41-0AA0 3VA5280-6EF41-0AA0 3VA5280-7EF41-0AA0<br />

100 3VA5210-5EF41-0AA0 3VA5210-6EF41-0AA0 3VA5210-7EF41-0AA0<br />

125 3VA5212-5EF41-0AA0 3VA5212-6EF41-0AA0 3VA5212-7EF41-0AA0<br />

150 3VA5215-5EF41-0AA0 3VA5215-6EF41-0AA0 3VA5215-7EF41-0AA0<br />

175 3VA5217-5EF41-0AA0 3VA5217-6EF41-0AA0 3VA5217-7EF41-0AA0<br />

200 3VA5220-5EF41-0AA0 3VA5220-6EF41-0AA0 3VA5220-7EF41-0AA0<br />

250 3VA5225-5EF41-0AA0 3VA5225-6EF41-0AA0 3VA5225-7EF41-0AA0<br />

TM240 ATAM 100% Neutral<br />

100 3VA5210-5GF41-0AA0 3VA5210-6GF41-0AA0 3VA5210-7GF41-0AA0<br />

125 3VA5212-5GF41-0AA0 3VA5212-6GF41-0AA0 3VA5212-7GF41-0AA0<br />

150 3VA5215-5GF41-0AA0 3VA5215-6GF41-0AA0 3VA5215-7GF41-0AA0<br />

175 3VA5217-5GF41-0AA0 3VA5217-6GF41-0AA0 3VA5217-7GF41-0AA0<br />

200 3VA5220-5GF41-0AA0 3VA5220-6GF41-0AA0 3VA5220-7GF41-0AA0<br />

250 3VA5225-5GF41-0AA0 3VA5225-6GF41-0AA0 3VA5225-7GF41-0AA0<br />

7-58<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA52 250A Thermal-magnetic Trip Circuit Breakers<br />

Revised on 08/31/20<br />

Technical information<br />

Interrupting Ratings for 3VA52<br />

Interrupting<br />

Class<br />

Breaker<br />

Type<br />

RMS Symmetrical Amperes (kA)<br />

Volts AC (50/60 Hz)<br />

Volts DC<br />

240 480Y/277V 480 600Y/347V 600 250 500 600 (3P)<br />

M MFAS 85 35 35 18 18 50 50 50<br />

H HFAS 100 65 65 25 25 85 85 85<br />

C CFAS 200 100 100 35 35 100 100 100<br />

Trip Settings for 3VA52<br />

TM210 - FTFM TM230 - FTAM TM240 - ATAM<br />

I n (A) I r (A) I i (A) I n (A) I r (A) I i (A) I n (A) I r (A) I i (A)<br />

40 40 400 70 70 350 420 490 560 630 700 70 56 350 420 490 560 630 700<br />

50 50 500 80 80 400 480 560 640 720 800 80 64 400 480 560 640 720 800<br />

60 60 600 90 90 450 540 630 720 810 900 100 80 500 600 700 800 900 1000<br />

70 70 700 100 100 500 600 700 800 900 1000 125 100 625 750 875 1000 1125 1250<br />

80 80 800 110 110 550 660 770 880 990 1100 150 120 750 900 1050 1200 1350 1500<br />

90 90 900 125 125 625 750 875 1000 1125 1250 175 140 875 1050 1225 1400 1575 1750<br />

100 100 1000 150 150 750 900 1050 1200 1350 1500 200 160 1000 1200 1400 1600 1800 2000<br />

110 110 1100 175 175 875 1050 1225 1400 1575 1750 250 200 1250 1500 1750 2000 2250 2500<br />

125 125 1250 200 200 1000 1200 1400 1600 1800 2000<br />

150 150 1500 225 225 1125 1350 1575 1800 2025 2250<br />

175 175 1750 250 250 1250 1500 1750 2000 2250 2500<br />

200 200 2000<br />

225 225 2250<br />

250 250 2500<br />

Connectors for 75C Wire for 3VA52<br />

Minimum<br />

cable size<br />

Maximum<br />

cable size<br />

Part Number<br />

(kit of 3 lugs)<br />

Part Number<br />

(kit of 4 lugs)<br />

Type<br />

Steel wrap around AWG 10 3/0 3VA9233-0JA11 3VA9234-0JA11<br />

(Cu cable only),<br />

single cable lugs<br />

AWG 4 350 kcmil 3VA9233-0JA12 3VA9234-0JA12<br />

Aluminum body lug AWG 14 1/0 3VA9233-0JB11 3VA9234-0JB11<br />

(Cu/Al cable),<br />

single cable lugs<br />

AWG 6 350 kcmil 3VA9233-0JB12 3VA9234-0JB12<br />

Aluminum body lug AWG 14 1/0 3VA9233-0JG11 3VA9234-0JG11<br />

(Cu/Al cable) with control<br />

wire tap, single cable lugs AWG 6 350 kcmil 3VA9233-0JG12 3VA9234-0JG12<br />

Aluminum body lug large<br />

(Cu/Al cable) single cable<br />

lugs with 1 extended<br />

AWG 2 350 kcmil 3VA9233-0JJ13 3VA9234-0JJ13<br />

terminal cover<br />

Aluminum body lug large<br />

with control wire tap<br />

(Cu/Al cable) single cable AWG 2 350 kcmil 3VA9233-0JC13 3VA9234-0JC13<br />

lugs and 1 extended<br />

terminal cover<br />

Aluminum body lug,<br />

2 cables (Cu/Al cable)<br />

with control wire tap and<br />

AWG 4 300 kcmil 3VA9233-0JJ22 3VA9234-0JJ22<br />

1 extended terminal cover<br />

Distribution lug, 6 Cables<br />

(Cu/Al cable) with 1 AWG 14 AWG 2 3VA9233-0JF60 3VA9234-0JF60<br />

extended terminal cover<br />

Copper body lug<br />

(Cu cable only)<br />

AWG 14 1/0 3VA9233-0JD11 3VA9234-0JD11<br />

single cable lugs<br />

AWG 6 350 kcmil 3VA9233-0JD12 3VA9234-0JD12<br />

Copper body lug with AWG 14 1/0 3VA9233-0JK11 3VA9234-0JK11<br />

control wire tap (Cu cable<br />

only) single cable lugs AWG 6 350 kcmil 3VA9233-0JK12 3VA9234-0JK12<br />

See page 7-81 for internal accessory<br />

part numbers.<br />

4<br />

3VA UL Molded Case Circuit Breakers<br />

Accessories and Spare Parts<br />

Internal accessories<br />

Design<br />

Internal accessories<br />

Optional equipment<br />

Auxiliary switch<br />

Auxiliary switch<br />

Leading<br />

changeover switch<br />

Alarm switch<br />

Trip alarm switch<br />

Auxiliary release<br />

Shunt trip flexible<br />

Shunt trip left<br />

Undervoltage release<br />

Universal release<br />

Other<br />

Cylinder lock (type Ronis)<br />

Slot No.:<br />

Type<br />

AUX_HQ<br />

AUX_HQ_el<br />

AUX_HP<br />

LCS_HQ<br />

LCS_HQ_el<br />

LCS_HP<br />

Type<br />

TAS_HQ<br />

TAS_HQ_el<br />

TAS_HP<br />

Type<br />

STF<br />

STL<br />

UVR<br />

UNI<br />

3VA5<br />

250 A<br />

2(3)-pole & 3-pole<br />

250 A<br />

24 23 22 21 11 12 13 14<br />

x x x x x x x x<br />

x x x x x x x x<br />

x x x x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x x x x<br />

x x x x<br />

x x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

I201_19494<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-59


3VA Molded Case Circuit Breakers<br />

3VA62 250A Electronic Trip Circuit Breakers<br />

Revised on 04/30/20<br />

Selection<br />

Ordering Information<br />

3VA62 250A 3-Pole<br />

The catalog numbers listed below are for complete, non-interchangable<br />

trip circuit breakers without lugs.<br />

Order required lugs or connection technology separately for field installation.<br />

All 3VA62 electronic trip circuit breakers are UL listed for reverse feed applications.<br />

All 3VA62 electronic trip circuit breakers are available with 100% ratings.<br />

For 100% rated electronic trip circuit breakers, change the 13th digit of the<br />

catalog number to the number "2". (For example, a 35KA @480VAC, 100A,<br />

3-pole, 100% rated 3VA62 would be catalog number 3VA6210-5HL31-2AA0)<br />

Requires the use of rated lugs — see lug table below.<br />

All 3VA6 circuit breakers are certified to UL 489 Supplement SB, are marked<br />

“Naval”, and are suitable for use at 50C.<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

3VA62 250A Frame 3-Pole Electronic Trip Unit<br />

Continuous<br />

Ampere<br />

M-Interrupting Class<br />

(MFAE)<br />

H-Interrupting Class<br />

(HFAE)<br />

C-Interrupting Class<br />

(CFAE)<br />

L-Interrupting Class<br />

(LFAE)<br />

E-Interrupting Class<br />

(EFAE)<br />

Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number<br />

ETU320 LI with dials<br />

100 3VA6210-5HL31-0AA0 3VA6210-6HL31-0AA0 3VA6210-7HL31-0AA0 3VA6210-8HL31-0AA0 —<br />

250 3VA6225-5HL31-0AA0 3VA6225-6HL31-0AA0 3VA6225-7HL31-0AA0 3VA6225-8HL31-0AA0 3VA6225-0HL31-0AA0<br />

ETU330 LIG with dials<br />

100 3VA6210-5HM31-0AA0 3VA6210-6HM31-0AA0 3VA6210-7HM31-0AA0 3VA6210-8HM31-0AA0 —<br />

250 3VA6225-5HM31-0AA0 3VA6225-6HM31-0AA0 3VA6225-7HM31-0AA0 3VA6225-8HM31-0AA0 3VA6225-0HM31-0AA0<br />

ETU350 LSI with dials<br />

100 3VA6210-5HN31-0AA0 3VA6210-6HN31-0AA0 3VA6210-7HN31-0AA0 3VA6210-8HN31-0AA0 —<br />

250 3VA6225-5HN31-0AA0 3VA6225-6HN31-0AA0 3VA6225-7HN31-0AA0 3VA6225-8HN31-0AA0 3VA6225-0HN31-0AA0<br />

ETU550 LSI with LCD<br />

100 3VA6210-5JP31-0AA0 3VA6210-6JP31-0AA0 3VA6210-7JP31-0AA0 3VA6210-8JP31-0AA0 —<br />

250 3VA6225-5JP31-0AA0 3VA6225-6JP31-0AA0 3VA6225-7JP31-0AA0 3VA6225-8JP31-0AA0 —<br />

ETU556 LSI(G Alarm) with LCD<br />

100 3VA6210-5JT31-0AA0 3VA6210-6JT31-0AA0 3VA6210-7JT31-0AA0 3VA6210-8JT31-0AA0 —<br />

250 3VA6225-5JT31-0AA0 3VA6225-6JT31-0AA0 3VA6225-7JT31-0AA0 3VA6225-8JT31-0AA0 —<br />

ETU560 LSIG with LCD<br />

100 3VA6210-5JQ31-0AA0 3VA6210-6JQ31-0AA0 3VA6210-7JQ31-0AA0 3VA6210-8JQ31-0AA0 —<br />

250 3VA6225-5JQ31-0AA0 3VA6225-6JQ31-0AA0 3VA6225-7JQ31-0AA0 3VA6225-8JQ31-0AA0 —<br />

ETU820 LI with LCD and Metering<br />

100 3VA6210-5KL31-0AA0 3VA6210-6KL31-0AA0 3VA6210-7KL31-0AA0 3VA6210-8KL31-0AA0 —<br />

250 3VA6225-5KL31-0AA0 3VA6225-6KL31-0AA0 3VA6225-7KL31-0AA0 3VA6225-8KL31-0AA0 —<br />

ETU830 LIG with LCD and Metering<br />

100 3VA6210-5KM31-0AA0 3VA6210-6KM31-0AA0 3VA6210-7KM31-0AA0 3VA6210-8KM31-0AA0 —<br />

250 3VA6225-5KM31-0AA0 3VA6225-6KM31-0AA0 3VA6225-7KM31-0AA0 3VA6225-8KM31-0AA0 —<br />

ETU850 LSI with LCD and Metering<br />

100 3VA6210-5KP31-0AA0 3VA6210-6KP31-0AA0 3VA6210-7KP31-0AA0 3VA6210-8KP31-0AA0 —<br />

250 3VA6225-5KP31-0AA0 3VA6225-6KP31-0AA0 3VA6225-7KP31-0AA0 3VA6225-8KP31-0AA0 —<br />

ETU856 LSI(G Alarm) with LCD and Metering<br />

100 3VA6210-5KT31-0AA0 3VA6210-6KT31-0AA0 3VA6210-7KT31-0AA0 3VA6210-8KT31-0AA0 —<br />

250 3VA6225-5KT31-0AA0 3VA6225-6KT31-0AA0 3VA6225-7KT31-0AA0 3VA6225-8KT31-0AA0 3VA6225-0KT31-0AA0<br />

ETU860 LSIG with LCD and Metering<br />

100 3VA6210-5KQ31-0AA0 3VA6210-6KQ31-0AA0 3VA6210-7KQ31-0AA0 3VA6210-8KQ31-0AA0 —<br />

250 3VA6225-5KQ31-0AA0 3VA6225-6KQ31-0AA0 3VA6225-7KQ31-0AA0 3VA6225-8KQ31-0AA0 3VA6225-0KQ31-0AA0<br />

7-60<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA62 250A Electronic Trip Circuit Breakers<br />

Revised on 04/30/20<br />

Selection<br />

Ordering Information<br />

3VA62 250A 4-Pole<br />

The catalog numbers listed below are for complete, non-interchangable<br />

trip circuit breakers without lugs.<br />

Order required lugs or connection technology separately for field installation.<br />

All 3VA62 electronic trip circuit breakers are UL listed for reverse feed applications.<br />

All 3VA62 electronic trip circuit breakers are available with 100% ratings.<br />

For 100% rated electronic trip circuit breakers, change the 13th digit of the<br />

catalog number to the number "2". (For example, a 35KA @480VAC, 100A,<br />

3-pole, 100% rated 3VA62 would be catalog number 3VA6210-5HL31-2AA0)<br />

Requires the use of rated lugs — see lug table below.<br />

All 3VA6 circuit breakers are certified to UL 489 Supplement SB, are marked<br />

“Naval”, and are suitable for use at 50C.<br />

3VA62 250A Frame 4-Pole Electronic Trip Unit<br />

Continuous<br />

Ampere<br />

M-Interrupting Class<br />

(MFAE)<br />

H-Interrupting Class<br />

(HFAE)<br />

C-Interrupting Class<br />

(CFAE)<br />

L-Interrupting Class<br />

(LFAE)<br />

E-Interrupting Class<br />

(EFAE)<br />

Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number<br />

ETU320 LI with dials<br />

100 3VA6210-5HL41-0AA0 3VA6210-6HL41-0AA0 3VA6210-7HL41-0AA0 3VA6210-8HL41-0AA0 —<br />

250 3VA6225-5HL41-0AA0 3VA6225-6HL41-0AA0 3VA6225-7HL41-0AA0 3VA6225-8HL41-0AA0 3VA6225-0HL41-0AA0<br />

ETU330 LIG with dials<br />

100 3VA6210-5HM41-0AA0 3VA6210-6HM41-0AA0 3VA6210-7HM41-0AA0 3VA6210-8HM41-0AA0 —<br />

250 3VA6225-5HM41-0AA0 3VA6225-6HM41-0AA0 3VA6225-7HM41-0AA0 3VA6225-8HM41-0AA0 3VA6225-0HM41-0AA0<br />

ETU350 LSI with dials<br />

100 3VA6210-5HN41-0AA0 3VA6210-6HN41-0AA0 3VA6210-7HN41-0AA0 3VA6210-8HN41-0AA0 —<br />

250 3VA6225-5HN41-0AA0 3VA6225-6HN41-0AA0 3VA6225-7HN41-0AA0 3VA6225-8HN41-0AA0 3VA6225-0HN41-0AA0<br />

ETU550 LSI with LCD<br />

100 3VA6210-5JP41-0AA0 3VA6210-6JP41-0AA0 3VA6210-7JP41-0AA0 3VA6210-8JP41-0AA0 —<br />

250 3VA6225-5JP41-0AA0 3VA6225-6JP41-0AA0 3VA6225-7JP41-0AA0 3VA6225-8JP41-0AA0 —<br />

ETU556 LSI(G Alarm) with LCD<br />

100 3VA6210-5JT41-0AA0 3VA6210-6JT41-0AA0 3VA6210-7JT41-0AA0 3VA6210-8JT41-0AA0 —<br />

250 3VA6225-5JT41-0AA0 3VA6225-6JT41-0AA0 3VA6225-7JT41-0AA0 3VA6225-8JT41-0AA0 —<br />

ETU560 LSIG with LCD<br />

100 3VA6210-5JQ41-0AA0 3VA6210-6JQ41-0AA0 3VA6210-7JQ41-0AA0 3VA6210-8JQ41-0AA0 —<br />

250 3VA6225-5JQ41-0AA0 3VA6225-6JQ41-0AA0 3VA6225-7JQ41-0AA0 3VA6225-8JQ41-0AA0 —<br />

ETU820 LI with LCD and Metering<br />

100 3VA6210-5KL41-0AA0 3VA6210-6KL41-0AA0 3VA6210-7KL41-0AA0 3VA6210-8KL41-0AA0 —<br />

250 3VA6225-5KL41-0AA0 3VA6225-6KL41-0AA0 3VA6225-7KL41-0AA0 3VA6225-8KL41-0AA0 —<br />

ETU830 LIG with LCD and Metering<br />

100 3VA6210-5KM41-0AA0 3VA6210-6KM41-0AA0 3VA6210-7KM41-0AA0 3VA6210-8KM41-0AA0 —<br />

250 3VA6225-5KM41-0AA0 3VA6225-6KM41-0AA0 3VA6225-7KM41-0AA0 3VA6225-8KM41-0AA0 —<br />

ETU850 LSI with LCD and Metering<br />

100 3VA6210-5KP41-0AA0 3VA6210-6KP41-0AA0 3VA6210-7KP41-0AA0 3VA6210-8KP41-0AA0 —<br />

250 3VA6225-5KP41-0AA0 3VA6225-6KP41-0AA0 3VA6225-7KP41-0AA0 3VA6225-8KP41-0AA0 —<br />

ETU856 LSI(G Alarm) with LCD and Metering<br />

100 3VA6210-5KT41-0AA0 3VA6210-6KT41-0AA0 3VA6210-7KT41-0AA0 3VA6210-8KT41-0AA0 —<br />

250 3VA6225-5KT41-0AA0 3VA6225-6KT41-0AA0 3VA6225-7KT41-0AA0 3VA6225-8KT41-0AA0 3VA6225-0KT41-0AA0<br />

ETU860 LSIG with LCD and Metering<br />

100 3VA6210-5KQ41-0AA0 3VA6210-6KQ41-0AA0 3VA6210-7KQ41-0AA0 3VA6210-8KQ41-0AA0 —<br />

250 3VA6225-5KQ41-0AA0 3VA6225-6KQ41-0AA0 3VA6225-7KQ41-0AA0 3VA6225-8KQ41-0AA0 3VA6225-0KQ41-0AA0<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-61


3VA Molded Case Circuit Breakers<br />

3VA62 250A Electronic Trip Circuit Breakers<br />

Revised on 04/30/20<br />

Technical information<br />

Connectors for 75C wire for 3VA62<br />

Type<br />

Minimum<br />

cable size<br />

Maximum<br />

cable size<br />

Part Number<br />

(kit of 3 lugs)<br />

Part Number<br />

(kit of 4 lugs)<br />

Steel Wrap around (Cu cable only)<br />

AWG 10 3/0 3VA9143-0JA12 3VA9144-0JA12<br />

single cable lugs a AWG 4 350 kcmil 3VA9243-0JA12 3VA9244-0JA12<br />

Steel Wrap around (Cu cable only)<br />

single cable lugs with control wire tap<br />

AWG 10 3/0 3VA9143-0JH12 3VA9144-0JH12<br />

AWG 4 350 kcmil 3VA9243-0JH12 3VA9244-0JH12<br />

Aluminum Body Lug (Cu/Al cable)<br />

AWG 14 1/0 3VA9143-0JB11 3VA9144-0JB11<br />

single cable lugs a AWG 6 350 kcmil 3VA9243-0JB12 3VA9244-0JB12<br />

Aluminum body lug with control wire tap<br />

AWG 14 1/0 3VA9143-0JG11 3VA9144-0JG11<br />

(Cu/Al cable) single cable lugs a AWG 6 350 kcmil 3VA9243-0JG12 3VA9244-0JG12<br />

Aluminum body lug large (Cu/Al cable)<br />

single cable lugs and 1 ext’d terminal cover a AWG 2 350 kcmil 3VA9243-0JJ13 3VA9244-0JJ13<br />

Aluminum body lug large with control wire tap<br />

(Cu/Al cable) single cable lugs and<br />

AWG 2 350 kcmil 3VA9243-0JC13 3VA9244-0JC13<br />

1 extended terminal cover a<br />

Aluminum body lug, 2 cables (Cu/Al cable)<br />

with 1 extended terminal cover a AWG 4 300 kcmil 3VA9243-0JJ22 3VA9244-0JJ22<br />

Aluminum body lug, 2 cables (Cu/Al cable) with<br />

control wire tap and 1 extended terminal cover a AWG 4 300 kcmil 3VA9243-0JC22 3VA9244-0JC22<br />

Distribution lug, 6 Cables (Cu/Al cable) with<br />

1 extended terminal cover a AWG 14 AWG 2 3VA9243-0JF60 3VA9244-0JF60<br />

Copper body lug (Cu cable only)<br />

single cable lugs<br />

Copper body lug (Cu cable only) with control<br />

wire tap single cable lugs<br />

AWG 14 1/0 3VA9143-0JD11 a 3VA9144-0JD11 a<br />

AWG 6 350 kcmil 3VA9243-0JD12 b 3VA9244-0JD12 b<br />

AWG 14 1/0 3VA9143-0JK11 a 3VA9144-0JK11 a<br />

AWG 6 350 kcmil 3VA9243-0JK12 b 3VA9244-0JK12 b<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Interrupting Ratings for 3VA62<br />

Interrupting<br />

Class<br />

Dimensions<br />

Breaker<br />

Type<br />

RMS Symmetrical Amperes (kA)<br />

Volts AC (50/60 Hz)<br />

240 480Y/277V 480 600Y/347V 600<br />

M MFAE 100 35 35 18 18<br />

H HFAE 100 65 65 22 22<br />

C CFAE 200 100 100 35 35<br />

L LFAE 200 150 150 50 50<br />

E EFAE — 200 200 100 100<br />

Shipping Weight<br />

Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg<br />

3VA62 3 4.1 (105) 7.8 (198) 3.4 (86) 5.5 2.5<br />

3VA62 4 5.5 (140) 7.8 (198) 3.4 (86) 7.1 3.2<br />

Enclosures (3-pole only)<br />

Nema Type<br />

Catalog Number<br />

1 surface 3VAE250N1S<br />

1 flush 3VAE250N1F<br />

3R<br />

3VAE250N3R<br />

12 3VAE250N12<br />

4X (304)<br />

3VAE250N4X<br />

4X (316)<br />

3VAE250N4X316<br />

Neutral<br />

N250X<br />

200% Neutral N2250X<br />

a Meets requirements for 100% rated breakers up to 100A.<br />

b Meets requirements for 100% rated breakers up to 250A,<br />

requires the use of 90 degree wire.<br />

7-62<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA62 250A Electronic Trip Circuit Breakers<br />

Revised on 09/30/19<br />

Technical information<br />

Trip Settings for 3VA62<br />

ETU320-LI, ETU330-LIG, ETU350-LSI<br />

Continuous<br />

Amperage LI, LIG, LSI LSI LIG<br />

LI, LIG, LSI<br />

4P only<br />

I sd= xIr<br />

I n (Amp) I r(Amp) (L) t ld (sec) (L) I i (Amp) (I) a (Amp) (S) t sd (sec) (S) I g (Amp) (G) I N=xI r (Amp)<br />

100 40 - 100 0.5 - 17 150-1200 1.5 - 10<br />

20 - 100 0.5 - 1 / OFF<br />

0.08 - 0.4<br />

250 100 - 250 0.5 - 13 375-2500 1.5 - 10 50 - 250 0.5 - 1 / OFF<br />

a I i for ETU350 is fixed at the maximum level shown in table.<br />

ETU550-LSI, ETU556 LSI(A), ETU560-LSIG, ETU820-LI, ETU830-LIG, ETU850-LSI, ETU856 LSI(A), ETU860-LSIG<br />

Continuous<br />

Amperage LI, LIG, LSI, LSIG, LSI(G) LSI, LSIG, LSI(G) LIG, LSIG, LSI(G)<br />

LSI 3P with<br />

External CT<br />

LI, LIG, LSI, LSIG,<br />

LSI(G) 4P only<br />

I n (Amp) I r(Amp) (L) t ld (sec) (L) I i (Amp) (I) I sd (Amp) (S) t sd (sec) (S) I g (Amp) (G) t g (G) I N=xI r (Amp) I N (Amp)<br />

100 40 - 100 0.5 - 25 150-1200 60 - 1000<br />

20 - 100<br />

20 - 160 / OFF 20 - 160 / OFF<br />

0.05 - 0.5<br />

0.05 - 0.8<br />

250 100 - 250 0.5 - 13 375-2500 150 - 2500 50 - 250 50 - 400 / OFF 50 - 250 / OFF<br />

For specific trip settings refer to the Electronic Trip Unit section 3VA of the UL 3VA Molded Systems Case Manual, Circuit Breakers<br />

which can be found in the document download center at https://www.siemens.com/download?BTLV_50412<br />

Accessories and Spare Parts<br />

Internal accessories<br />

Internal accessories<br />

Optional equipment<br />

3VA6<br />

3VA6<br />

150/250 A 150/250 A<br />

3-pole<br />

4-pole<br />

250 A 250 A<br />

Auxiliary switch<br />

Slot No.:<br />

Type<br />

24 23 22 21 11 12 13 14 34 33 32 31 24 23 22 21 11 12 13 14<br />

AUX_HQ x x x x x x x x x x x x x x x x x x x x<br />

Auxiliary switch<br />

AUX_HQ_el x x x x x x x x x x x x x x x x x x x x<br />

AUX_HP x x x x x x x x x x<br />

x x x x x<br />

LCS_HQ x x<br />

Leading changeover switch<br />

LCS_HQ_el x x<br />

LCS_HP x x<br />

Alarm switch<br />

Type<br />

7<br />

TAS_HQ x x x x x x x x<br />

Trip alarm switch<br />

Electrical alarm switch<br />

Auxiliary release<br />

Shunt trip flexible<br />

Shunt trip left<br />

Undervoltage release<br />

TAS_HQ_el x x x x x x x x<br />

TAS_HP x x x x<br />

EAS_HQ x x<br />

EAS_HQ_el x x<br />

Type<br />

STF x x x x<br />

STL x x<br />

UVR x x<br />

4<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Universal release<br />

UNI x x<br />

ETU/communication<br />

Type<br />

Communication module<br />

Breaker data server<br />

COM060<br />

x<br />

x<br />

24 V module<br />

x<br />

x<br />

Other<br />

Cylinder lock (type Ronis)<br />

x<br />

x<br />

I201_19495<br />

See page 7-81 for internal accessory<br />

part numbers.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-63


3VA Molded Case Circuit Breakers<br />

3VA53 400A Thermal-magnetic Trip Circuit Breakers<br />

Revised on 11/30/19<br />

Selection<br />

3VA53 400A, 2-Pole in 3-Pole Frame, Thermal-Magnetic Trip Unit<br />

Cont.<br />

Ampere<br />

Rating<br />

M-Interrupting Class<br />

(MJAS)<br />

H-Interrupting Class<br />

(HJAS)<br />

C-Interrupting Class<br />

(CJAS)<br />

Catalog Number Catalog Number Catalog Number<br />

TM230 FTAM<br />

200 3VA5320-5EC61-0AA0 3VA5320-6EC61-0AA0 3VA5320-7EC61-0AA0<br />

225 3VA5322-5EC61-0AA0 3VA5322-6EC61-0AA0 3VA5322-7EC61-0AA0<br />

250 3VA5325-5EC61-0AA0 3VA5325-6EC61-0AA0 3VA5325-7EC61-0AA0<br />

300 3VA5330-5EC61-0AA0 3VA5330-6EC61-0AA0 3VA5330-7EC61-0AA0<br />

350 3VA5335-5EC61-0AA0 3VA5335-6EC61-0AA0 3VA5335-7EC61-0AA0<br />

400 3VA5340-5EC61-0AA0 3VA5340-6EC61-0AA0 3VA5340-7EC61-0AA0<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

3VA53 400A Frame, 3-Pole Frame, Thermal-Magnetic Trip Unit<br />

Cont.<br />

Ampere<br />

Rating<br />

M-Interrupting Class<br />

(MJAS)<br />

H-Interrupting Class<br />

(HJAS)<br />

C-Interrupting Class<br />

(CJAS)<br />

Catalog Number Catalog Number Catalog Number<br />

TM230 FTAM a<br />

200 3VA5320-5EC31-0AA0 3VA5320-6EC31-0AA0 3VA5320-7EC31-0AA0<br />

225 3VA5322-5EC31-0AA0 3VA5322-6EC31-0AA0 3VA5322-7EC31-0AA0<br />

250 3VA5325-5EC31-0AA0 3VA5325-6EC31-0AA0 3VA5325-7EC31-0AA0<br />

300 3VA5330-5EC31-0AA0 3VA5330-6EC31-0AA0 3VA5330-7EC31-0AA0<br />

350 3VA5335-5EC31-0AA0 3VA5335-6EC31-0AA0 3VA5335-7EC31-0AA0<br />

400 3VA5340-5EC31-0AA0 3VA5340-6EC31-0AA0 3VA5340-7EC31-0AA0<br />

TM240 ATAM<br />

200 3VA5320-5EF31-0AA0 3VA5320-6EF31-0AA0 3VA5320-7EF31-0AA0<br />

225 3VA5322-5EF31-0AA0 3VA5322-6EF31-0AA0 3VA5322-7EF31-0AA0<br />

250 3VA5325-5EF31-0AA0 3VA5325-6EF31-0AA0 3VA5325-7EF31-0AA0<br />

300 3VA5330-5EF31-0AA0 3VA5330-6EF31-0AA0 3VA5330-7EF31-0AA0<br />

350 3VA5335-5EF31-0AA0 3VA5335-6EF31-0AA0 3VA5335-7EF31-0AA0<br />

400 3VA5340-5EF31-0AA0 3VA5340-6EF31-0AA0 3VA5340-7EF31-0AA0<br />

Trip Settings for 3VA53<br />

TM230 - FTAM<br />

I n (Amp) I r(Amp) I i (Amp)<br />

200 200 1000 1200 1400 1600 1800 2000<br />

225 225 1125 1350 1575 1800 2025 2250<br />

250 250 1250 1500 1750 2000 2250 2500<br />

300 300 1500 1800 2100 2400 2700 3000<br />

350 350 1750 2100 2450 2800 3150 3500<br />

400 400 2000 2400 2800 3200 3600 4000<br />

TM240 - ATAM<br />

I n (Amp) I r(Amp) I i (Amp)<br />

200 160 1000 1200 1400 1600 1800 2000<br />

225 180 1125 1350 1575 1800 2025 2250<br />

250 200 1250 1500 1750 2000 2250 2500<br />

300 240 1500 1800 2100 2400 2700 3000<br />

350 280 1750 2100 2450 2800 3150 3500<br />

400 320 2000 2400 2800 3200 3600 4000<br />

3VA53 400A 3-Pole<br />

Ordering Information<br />

The catalog numbers listed here are<br />

for complete, non-interchangable trip<br />

circuit breakers without lugs.<br />

Order required lugs or connection<br />

technology separately for field<br />

installation.<br />

All 3VA53 thermal-magnetic trip<br />

circuit breakers are UL listed for<br />

reverse feed applications.<br />

For NAVAL rated thermal-magnetic<br />

trip circuit breakers, change the<br />

13th digit of the catalog number<br />

to the number "1". (For example, a<br />

35KA@480VAC, 400A, 3-pole, rated<br />

3VA53 would be catalog number<br />

3VA5340-5EC31-1AA0)<br />

a Available with NAVAL/50C ratings.<br />

7-64<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA53 400A Thermal-magnetic Trip Circuit Breakers<br />

Revised on 11/30/19<br />

Selection<br />

3VA53 400A Frame, 4-Pole Frame, Thermal-Magnetic Trip Unit<br />

Cont.<br />

Ampere<br />

Rating<br />

M-Interrupting Class<br />

(MJAS)<br />

H-Interrupting Class<br />

(HJAS)<br />

C-Interrupting Class<br />

(CJAS)<br />

Catalog Number Catalog Number Catalog Number<br />

TM230 FTAM Unprotected Neutral<br />

200 3VA5320-5EC41-0AA0 3VA5320-6EC41-0AA0 3VA5320-7EC41-0AA0<br />

225 3VA5322-5EC41-0AA0 3VA5322-6EC41-0AA0 3VA5322-7EC41-0AA0<br />

250 3VA5325-5EC41-0AA0 3VA5325-6EC41-0AA0 3VA5325-7EC41-0AA0<br />

300 3VA5330-5EC41-0AA0 3VA5330-6EC41-0AA0 3VA5330-7EC41-0AA0<br />

350 3VA5335-5EC41-0AA0 3VA5335-6EC41-0AA0 3VA5335-7EC41-0AA0<br />

400 3VA5340-5EC41-0AA0 3VA5340-6EC41-0AA0 3VA5340-7EC41-0AA0<br />

TM240 ATAM Unprotected Neutral<br />

200 3VA5320-5EF41-0AA0 3VA5320-6EF41-0AA0 3VA5320-7EF41-0AA0<br />

225 3VA5322-5EF41-0AA0 3VA5322-6EF41-0AA0 3VA5322-7EF41-0AA0<br />

250 3VA5325-5EF41-0AA0 3VA5325-6EF41-0AA0 3VA5325-7EF41-0AA0<br />

300 3VA5330-5EF41-0AA0 3VA5330-6EF41-0AA0 3VA5330-7EF41-0AA0<br />

350 3VA5335-5EF41-0AA0 3VA5335-6EF41-0AA0 3VA5335-7EF41-0AA0<br />

400 3VA5340-5EF41-0AA0 3VA5340-6EF41-0AA0 3VA5340-7EF41-0AA0<br />

TM230 FTAM 100% Neutral<br />

200 3VA5320-5GC41-0AA0 3VA5320-6GC41-0AA0 3VA5320-7GC41-0AA0<br />

225 3VA5322-5GC41-0AA0 3VA5322-6GC41-0AA0 3VA5322-7GC41-0AA0<br />

250 3VA5325-5GC41-0AA0 3VA5325-6GC41-0AA0 3VA5325-7GC41-0AA0<br />

300 3VA5330-5GC41-0AA0 3VA5330-6GC41-0AA0 3VA5330-7GC41-0AA0<br />

350 3VA5335-5GC41-0AA0 3VA5335-6GC41-0AA0 3VA5335-7GC41-0AA0<br />

400 3VA5340-5GC41-0AA0 3VA5340-6GC41-0AA0 3VA5340-7GC41-0AA0<br />

TM240 ATAM 100% Neutral<br />

200 3VA5320-5GF41-0AA0 3VA5320-6GF41-0AA0 3VA5320-7GF41-0AA0<br />

225 3VA5322-5GF41-0AA0 3VA5322-6GF41-0AA0 3VA5322-7GF41-0AA0<br />

250 3VA5325-5GF41-0AA0 3VA5325-6GF41-0AA0 3VA5325-7GF41-0AA0<br />

300 3VA5330-5GF41-0AA0 3VA5330-6GF41-0AA0 3VA5330-7GF41-0AA0<br />

350 3VA5335-5GF41-0AA0 3VA5335-6GF41-0AA0 3VA5335-7GF41-0AA0<br />

400 3VA5340-5GF41-0AA0 3VA5340-6GF41-0AA0 3VA5340-7GF41-0AA0<br />

Dimensions<br />

Shipping Weight<br />

Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg<br />

3VA53 3 6.4 (162) 10.3 (262) 6.7 (170) 11.5 5.2<br />

3VA53 4 8.2 (208) 10.3 (262) 6.7 (170) 15.0 6.8<br />

Interrupting Ratings for 3VA53<br />

Interrupting<br />

Class<br />

Breaker<br />

Type<br />

RMS Symmetrical Amperes (kA)<br />

Volts AC (50/60 Hz)<br />

240<br />

480Y/<br />

277V 480<br />

600Y/<br />

347V 600<br />

Volts DC<br />

250<br />

(2P)<br />

600<br />

(3P)<br />

750<br />

(3P)<br />

750<br />

(4P)<br />

4<br />

1000<br />

(4P)<br />

M MJAS 85 35 35 18 18 50 50 10 50 10<br />

H HJAS 100 65 65 25 25 85 85 10 85 10<br />

C CJAS 200 100 100 35 35 100 100 10 100 10<br />

3VA UL Molded Case Circuit Breakers<br />

3VA53 400A 4-Pole<br />

Accessories and Spare Parts<br />

Internal accessories<br />

Internal accessories<br />

Optional equipment<br />

Auxiliary switch<br />

Auxiliary switch<br />

Leading<br />

changeover<br />

switch<br />

Alarm switch<br />

Trip alarm switch<br />

Auxiliary release<br />

Shunt trip flexible<br />

Shunt trip left<br />

Undervoltage release<br />

Universal release<br />

Other<br />

Cylinder lock (type Ronis)<br />

Slot No.:<br />

Type<br />

LCS_HQ<br />

LCS_HQ_el<br />

LCS_HP<br />

Type<br />

TAS_HQ<br />

TAS_HQ_el<br />

TAS_HP<br />

Type<br />

3 & 4-pole<br />

25 24 23 22 21 11 12 13 14 15 35 34 33 32 31 2<br />

AUX_HQ x x x x x x x x x x x x x x x<br />

AUX_HQ_el x x x x x x x x x x x x x x x<br />

AUX_HP x x x x x x<br />

x x x x x x<br />

STF<br />

STL<br />

UVR<br />

UNI<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

3VA5<br />

400/600 A<br />

x<br />

x<br />

600 A<br />

x<br />

x<br />

x<br />

x x<br />

x x<br />

x<br />

x<br />

x<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

4/6 Siemens · 04/<strong>2017</strong><br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-65


3VA Molded Case Circuit Breakers<br />

3VA63 400A Electronic Trip Circuit Breakers<br />

Revised on 01/31/20<br />

Selection<br />

Ordering Information<br />

3VA63 400A 3-Pole<br />

The catalog numbers listed below are for complete, non-interchangable<br />

trip circuit breakers without lugs.<br />

Order required lugs or connection technology separately for field installation.<br />

All 3VA63 electronic trip circuit breakers are UL listed for reverse feed applications.<br />

3VA63 electronic trip circuit breakers are available with 100% ratings (250A only).<br />

For 100% rated electronic trip circuit breakers, change the 13th digit of the<br />

catalog number to the number "2". (For example, a 35KA @480VAC, 250A,<br />

3-pole, 100% rated 3VA63 would be catalog number 3VA6325-5HL31-2AA0)<br />

Requires the use of rated lugs — see lug table below.<br />

All 3VA6 circuit breakers are certified to UL 489 Supplement SB, are marked<br />

“Naval”, and are suitable for use at 50C.<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

3VA63 400A Frame 3-Pole Electronic Trip Unit<br />

Continuous<br />

Ampere<br />

M-Interrupting Class<br />

(MJAE)<br />

H-Interrupting Class<br />

(HJAE)<br />

C-Interrupting Class<br />

(CJAE)<br />

L-Interrupting Class<br />

(LJAE)<br />

E-Interrupting Class<br />

(EJAE)<br />

Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number<br />

ETU320 LI with dials<br />

250 3VA6325-5HL31-0AA0 3VA6325-6HL31-0AA0 3VA6325-7HL31-0AA0 3VA6325-8HL31-0AA0 3VA6325-0HL31-0AA0<br />

400 3VA6340-5HL31-0AA0 3VA6340-6HL31-0AA0 3VA6340-7HL31-0AA0 3VA6340-8HL31-0AA0 3VA6340-0HL31-0AA0<br />

ETU330 LIG with dials<br />

250 3VA6325-5HM31-0AA0 3VA6325-6HM31-0AA0 3VA6325-7HM31-0AA0 3VA6325-8HM31-0AA0 3VA6325-0HM31-0AA0<br />

400 3VA6340-5HM31-0AA0 3VA6340-6HM31-0AA0 3VA6340-7HM31-0AA0 3VA6340-8HM31-0AA0 3VA6340-0HM31-0AA0<br />

ETU350 LSI with dials<br />

250 3VA6325-5HN31-0AA0 3VA6325-6HN31-0AA0 3VA6325-7HN31-0AA0 3VA6325-8HN31-0AA0 3VA6325-0HN31-0AA0<br />

400 3VA6340-5HN31-0AA0 3VA6340-6HN31-0AA0 3VA6340-7HN31-0AA0 3VA6340-8HN31-0AA0 3VA6340-0HN31-0AA0<br />

ETU550 LSI with LCD<br />

250 3VA6325-5JP31-0AA0 3VA6325-6JP31-0AA0 3VA6325-7JP31-0AA0 3VA6325-8JP31-0AA0 —<br />

400 3VA6340-5JP31-0AA0 3VA6340-6JP31-0AA0 3VA6340-7JP31-0AA0 3VA6340-8JP31-0AA0 —<br />

ETU556 LSI(G Alarm) with LCD<br />

250 3VA6325-5JT31-0AA0 3VA6325-6JT31-0AA0 3VA6325-7JT31-0AA0 3VA6325-8JT31-0AA0 —<br />

400 3VA6340-5JT31-0AA0 3VA6340-6JT31-0AA0 3VA6340-7JT31-0AA0 3VA6340-8JT31-0AA0 —<br />

ETU560 LSIG with LCD<br />

250 3VA6325-5JQ31-0AA0 3VA6325-6JQ31-0AA0 3VA6325-7JQ31-0AA0 3VA6325-8JQ31-0AA0 —<br />

400 3VA6340-5JQ31-0AA0 3VA6340-6JQ31-0AA0 3VA6340-7JQ31-0AA0 3VA6340-8JQ31-0AA0 —<br />

ETU820 LI with LCD and Metering<br />

250 3VA6325-5KL31-0AA0 3VA6325-6KL31-0AA0 3VA6325-7KL31-0AA0 3VA6325-8KL31-0AA0 —<br />

400 3VA6340-5KL31-0AA0 3VA6340-6KL31-0AA0 3VA6340-7KL31-0AA0 3VA6340-8KL31-0AA0 —<br />

ETU830 LIG with LCD and Metering<br />

250 3VA6325-5KM31-0AA0 3VA6325-6KM31-0AA0 3VA6325-7KM31-0AA0 3VA6325-8KM31-0AA0 —<br />

400 3VA6340-5KM31-0AA0 3VA6340-6KM31-0AA0 3VA6340-7KM31-0AA0 3VA6340-8KM31-0AA0 —<br />

ETU850 LSI with LCD and Metering<br />

250 3VA6325-5KP31-0AA0 3VA6325-6KP31-0AA0 3VA6325-7KP31-0AA0 3VA6325-8KP31-0AA0 —<br />

400 3VA6340-5KP31-0AA0 3VA6340-6KP31-0AA0 3VA6340-7KP31-0AA0 3VA6340-8KP31-0AA0 —<br />

ETU856 LSI(G Alarm) with LCD and Metering<br />

250 3VA6325-5KT31-0AA0 3VA6325-6KT31-0AA0 3VA6325-7KT31-0AA0 3VA6325-8KT31-0AA0 3VA6325-0KT31-0AA0<br />

400 3VA6340-5KT31-0AA0 3VA6340-6KT31-0AA0 3VA6340-7KT31-0AA0 3VA6340-8KT31-0AA0 3VA6340-0KT31-0AA0<br />

ETU860 LSIG with LCD and Metering<br />

250 3VA6325-5KQ31-0AA0 3VA6325-6KQ31-0AA0 3VA6325-7KQ31-0AA0 3VA6325-8KQ31-0AA0 3VA6325-0KQ31-0AA0<br />

400 3VA6340-5KQ31-0AA0 3VA6340-6KQ31-0AA0 3VA6340-7KQ31-0AA0 3VA6340-8KQ31-0AA0 3VA6340-0KQ31-0AA0<br />

7-66<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA63 400A Electronic Trip Circuit Breakers<br />

Revised on 04/30/20<br />

Selection<br />

3VA63 400A 4-Pole<br />

Interrupting Ratings for 3VA63<br />

Interrupting<br />

Class<br />

Dimensions<br />

Breaker<br />

Type<br />

RMS Symmetrical Amperes (kA)<br />

Volts AC (50/60 Hz)<br />

240 480Y/277V 480 600Y/347V 600<br />

M MJAE 100 35 35 18 18<br />

H HJAE 100 65 65 22 22<br />

C CJAE 200 100 100 35 35<br />

L LJAE 200 150 150 50 50<br />

E EJAE — 200 200 100 100<br />

Shipping Weight<br />

Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg<br />

3VA63 3 6.4 (162) 10.3 (262) 6.7 (170) 11.0 5.2<br />

3VA63 4 8.2 (208) 10.3 (262) 6.7 (170) 15.0 6.8<br />

3VA63 400A Frame 4-Pole Electronic Trip Unit<br />

Continuous<br />

Ampere<br />

M-Interrupting Class<br />

(MJAE)<br />

H-Interrupting Class<br />

(HJAE)<br />

C-Interrupting Class<br />

(CJAE)<br />

L-Interrupting Class<br />

(LJAE)<br />

E-Interrupting Class<br />

(EJAE)<br />

Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number<br />

ETU320 LI with dials<br />

250 3VA6325-5HL41-0AA0 3VA6325-6HL41-0AA0 3VA6325-7HL41-0AA0 3VA6325-8HL41-0AA0 3VA6325-0HL31-0AA0<br />

400 3VA6340-5HL41-0AA0 3VA6340-6HL41-0AA0 3VA6340-7HL41-0AA0 3VA6340-8HL41-0AA0 3VA6340-0HL31-0AA0<br />

ETU330 LIG with dials<br />

250 3VA6325-5HM41-0AA0 3VA6325-6HM41-0AA0 3VA6325-7HM41-0AA0 3VA6325-8HM41-0AA0 3VA6325-0HM31-0AA0<br />

400 3VA6340-5HM41-0AA0 3VA6340-6HM41-0AA0 3VA6340-7HM41-0AA0 3VA6340-8HM41-0AA0 3VA6340-0HM31-0AA0<br />

ETU350 LSI with dials<br />

250 3VA6325-5HN41-0AA0 3VA6325-6HN41-0AA0 3VA6325-7HN41-0AA0 3VA6325-8HN41-0AA0 3VA6325-0HN31-0AA0<br />

400 3VA6340-5HN41-0AA0 3VA6340-6HN41-0AA0 3VA6340-7HN41-0AA0 3VA6340-8HN41-0AA0 3VA6340-0HN31-0AA0<br />

ETU550 LSI with LCD<br />

250 3VA6325-5JP41-0AA0 3VA6325-6JP41-0AA0 3VA6325-7JP41-0AA0 3VA6325-8JP41-0AA0 —<br />

400 3VA6340-5JP41-0AA0 3VA6340-6JP41-0AA0 3VA6340-7JP41-0AA0 3VA6340-8JP41-0AA0 —<br />

ETU556 LSI(G Alarm) with LCD<br />

250 3VA6325-5JT41-0AA0 3VA6325-6JT41-0AA0 3VA6325-7JT41-0AA0 3VA6325-8JT41-0AA0 —<br />

400 3VA6340-5JT41-0AA0 3VA6340-6JT41-0AA0 3VA6340-7JT41-0AA0 3VA6340-8JT41-0AA0 —<br />

ETU560 LSIG with LCD<br />

250 3VA6325-5JQ41-0AA0 3VA6325-6JQ41-0AA0 3VA6325-7JQ41-0AA0 3VA6325-8JQ41-0AA0 —<br />

400 3VA6340-5JQ41-0AA0 3VA6340-6JQ41-0AA0 3VA6340-7JQ41-0AA0 3VA6340-8JQ41-0AA0 —<br />

ETU820 LI with LCD and Metering<br />

250 3VA6325-5KL41-0AA0 3VA6325-6KL41-0AA0 3VA6325-7KL41-0AA0 3VA6325-8KL41-0AA0 —<br />

400 3VA6340-5KL41-0AA0 3VA6340-6KL41-0AA0 3VA6340-7KL41-0AA0 3VA6340-8KL41-0AA0 —<br />

ETU830 LIG with LCD and Metering<br />

250 3VA6325-5KM41-0AA0 3VA6325-6KM41-0AA0 3VA6325-7KM41-0AA0 3VA6325-8KM41-0AA0 —<br />

400 3VA6340-5KM41-0AA0 3VA6340-6KM41-0AA0 3VA6340-7KM41-0AA0 3VA6340-8KM41-0AA0 —<br />

ETU850 LSI with LCD and Metering<br />

250 3VA6325-5KP41-0AA0 3VA6325-6KP41-0AA0 3VA6325-7KP41-0AA0 3VA6325-8KP41-0AA0 —<br />

400 3VA6340-5KP41-0AA0 3VA6340-6KP41-0AA0 3VA6340-7KP41-0AA0 3VA6340-8KP41-0AA0 —<br />

ETU856 LSI(G Alarm) with LCD and Metering<br />

250 3VA6325-5KT41-0AA0 3VA6325-6KT41-0AA0 3VA6325-7KT41-0AA0 3VA6325-8KT41-0AA0 3VA6325-0KT31-0AA0<br />

400 3VA6340-5KT41-0AA0 3VA6340-6KT41-0AA0 3VA6340-7KT41-0AA0 3VA6340-8KT41-0AA0 3VA6340-0KT31-0AA0<br />

ETU860 LSIG with LCD and Metering<br />

250 3VA6325-5KQ41-0AA0 3VA6325-6KQ41-0AA0 3VA6325-7KQ41-0AA0 3VA6325-8KQ41-0AA0 3VA6325-0KQ31-0AA0<br />

400 3VA6340-5KQ41-0AA0 3VA6340-6KQ41-0AA0 3VA6340-7KQ41-0AA0 3VA6340-8KQ41-0AA0 3VA6340-0KQ31-0AA0<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-67


3VA Molded Case Circuit Breakers<br />

3VA63 400A Electronic Trip Circuit Breakers<br />

Revised on 04/30/20<br />

Technical information<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Connections for 75C wire for 3VA53 and 3VA63<br />

Type<br />

Minimum<br />

cable size<br />

Maximum<br />

cable size<br />

Part Number<br />

(kit of 3 lugs)<br />

Part Number<br />

(kit of 4 lugs)<br />

Steel wrap around (Cu cable only) single cable lugs a 1/0 500 kcmil 3VA9473-0JA13 3VA9474-0JA13<br />

Steel wrap around (Cu cable only)<br />

single cable lugs with control wire tap<br />

1/0 500 kcmil 3VA9473-0JH13 3VA9474-0JH13<br />

Aluminum body lug (Cu/Al cable) single cable lugs a AWG 1 600 kcmil 3VA9373-0JB13 3VA9374-0JB13<br />

Aluminum body lug with control wire tap<br />

(Cu/Al cable) single cable lugs a AWG 1 600 kcmil 3VA9373-0JG13 3VA9374-0JG13<br />

Aluminum body lug, 2 cables (Cu/Al cable) with<br />

1 extended terminal cover<br />

2/0 600 kcmil 3VA9473-0JJ23 3VA9474-0JJ23<br />

Aluminum body lug, 2 cables (Cu/Al cable) with<br />

control wire tap and 1 extended terminal cover<br />

2/0 600 kcmil 3VA9473-0JC23 3VA9474-0JC23<br />

Distribution lug, 6 Cables (Cu/Al cable) with<br />

1 extended terminal cover a AWG 14 AWG 2 3VA9373-0JF60 3VA9374-0JF60<br />

Copper body lug (Cu cable only) single cable lugs a AWG 1 600 kcmil 3VA9373-0JD13 3VA9374-0JD13<br />

Copper body lug (Cu cable only) with<br />

control wire tap single cable lugs a AWG 1 600 kcmil 3VA9373-0JK13 3VA9374-0JK13<br />

Copper body lug, 2 cables (Cu cable only) with<br />

1 extended terminal cover a 2/0 600 kcmil 3VA9473-0JE23 3VA9474-0JE23<br />

3VA UL Molded Case Circuit Breakers<br />

Copper body lug, 2 cables (Cu cable only) with control<br />

wire tap and 1 extended terminal cover a 2/0 Accessories and 600 Spare kcmil Parts 3VA9473-0JL23 3VA9474-0JL23<br />

Internal accessories<br />

a Meets requirements for 100% rated breakers up to 250A.<br />

Internal accessories<br />

3VA5 & 3VA6<br />

3VA5 & 3VA6<br />

Enclosures for 3VA53 and<br />

3VA63 (3-pole only)<br />

NEMA Type Catalog Number<br />

1 Surface 3VAE6001S<br />

1 Flush 3VAE6001F<br />

3R<br />

3VAE6003R<br />

12 3VAE60012<br />

4X (304)<br />

4X (316)<br />

Neutral<br />

3VAE6004X<br />

3VAE6004X316<br />

HN656ACB<br />

200% Neutral HN678ACB<br />

Trip Settings for 3VA63<br />

ETU320-LI, ETU330-LIG, ETU350-LSI<br />

Continuous<br />

Amperage LI, LIG, LSI LSI LIG<br />

LI, LIG, LSI<br />

4P only<br />

I sd= xIr<br />

I n (Amp) I r(Amp) (L) t ld (sec) (L) I i (Amp) (I) d (Amp) (S) t sd (sec) (S) I g (Amp) (G) I N=xI r (Amp)<br />

250 100 - 250 0.5 - 17 375-3000 1.5 - 10<br />

50 - 250 0.5 - 1 / OFF<br />

0.08 - 0.4<br />

400 150 - 400 0.5 - 17 600-4000 1.5 - 10 80 - 400 0.5 - 1 / OFF<br />

d I i for ETU350 is fixed at the maximum level shown in table.<br />

ETU550-LSI, ETU556 LSI(A), ETU560-LSIG, ETU820-LI, ETU830-LIG, ETU850-LSI, ETU856 LSI(A), ETU860-LSIG<br />

Continuous<br />

Amperage LI, LIG, LSI, LSIG, LSI(G) LSI, LSIG, LSI(G) LIG, LSIG, LSI(G)<br />

4<br />

Optional equipment<br />

Auxiliary switch<br />

Auxiliary switch<br />

Leading changeover switch<br />

Alarm switch<br />

Trip alarm switch<br />

<br />

Electrical alarm switch<br />

Auxiliary release<br />

Shunt trip flexible<br />

Shunt trip left<br />

Undervoltage release<br />

Universal release<br />

<br />

ETU/communication<br />

Communication module<br />

Breaker data server<br />

24 V module<br />

Other<br />

Cylinder lock (type Ronis)<br />

UVR x x<br />

UNI x x<br />

Type<br />

LSI 3P with<br />

External CT<br />

See page 7-81 for internal<br />

accessory part numbers.<br />

LI, LIG, LSI, LSIG,<br />

LSI(G) 4P only<br />

I n (Amp) I r(Amp) (L) t ld (sec) (L) I i (Amp) (I) I sd (Amp) (S) t sd (sec) (S) I g (Amp) (G) t g (G) I N=xI r (Amp) I N (Amp)<br />

250 100 - 250 0.5 - 25 375-3000 150 - 2500<br />

50 - 250<br />

50 - 400 / OFF 50 - 400 / OFF<br />

0.05 - 0.5<br />

0.05 - 0.8<br />

400 150 - 400 0.5 - 17 600-4000 240 - 4000 4/6 Siemens · 04/<strong>2017</strong>80 - 400 80 - 640 / OFF 80 - 400 / OFF<br />

For specific trip settings refer to the Electronic Trip Unit section of the 3VA Systems Manual,<br />

which can be found in the document download center at https://www.siemens.com/download?BTLV_50412<br />

Slot No.:<br />

Type<br />

Type<br />

Type<br />

3-pole<br />

4-pole<br />

25 24 23 22 21 11 12 13 14 15 35 34 33 32 31 25 24 23 22 21 11 12 13 14 15<br />

AUX_HQ x x x x x x x x x x x x x x x x x x x x x x x x x<br />

AUX_HQ_el x x x x x x x x x x x x x x x x x x x x x x x x x<br />

AUX_HP x x x x x x x x x x<br />

x x x x x x x x x x<br />

LCS_HQ<br />

LCS_HQ_el<br />

LCS_HP<br />

TAS_HQ<br />

TAS_HQ_el<br />

TAS_HP<br />

EAS_HQ<br />

EAS_HQ_el<br />

STF<br />

STL<br />

COM060<br />

x<br />

x<br />

x<br />

x<br />

400/600 A<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

400/600 A<br />

600 A 600 A<br />

c These accessories are for<br />

electronic trip breakers only.<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

I201_19495<br />

7-68<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA54 600A Thermal-magnetic Trip Circuit Breakers<br />

Revised on 09/30/20<br />

Selection<br />

3VA54 600A, 2-Pole in 3-Pole Frame, Thermal-Magnetic Trip Unit<br />

Cont.<br />

Ampere<br />

Rating<br />

M-Interrupting Class<br />

(MLAS)<br />

H-Interrupting Class<br />

(HLAS)<br />

C-Interrupting Class<br />

(CLAS)<br />

Catalog Number Catalog Number Catalog Number<br />

TM230 FTAM<br />

450 3VA5445-5EC61-0AA0 3VA5445-6EC61-0AA0 3VA5445-7EC61-0AA0<br />

500 3VA5450-5EC61-0AA0 3VA5450-6EC61-0AA0 3VA5450-7EC61-0AA0<br />

600 3VA5460-5EC61-0AA0 3VA5460-6EC61-0AA0 3VA5460-7EC61-0AA0<br />

3VA54 600A Frame, 3-Pole Frame, Thermal-Magnetic Trip Unit<br />

Cont.<br />

Ampere<br />

Rating<br />

M-Interrupting Class<br />

(MLAS)<br />

H-Interrupting Class<br />

(HLAS)<br />

C-Interrupting Class<br />

(CLAS)<br />

Catalog Number Catalog Number Catalog Number<br />

TM230 FTAM a<br />

450 3VA5445-5EC31-0AA0 3VA5445-6EC31-0AA0 3VA5445-7EC31-0AA0<br />

500 3VA5450-5EC31-0AA0 3VA5450-6EC31-0AA0 3VA5450-7EC31-0AA0<br />

600 3VA5460-5EC31-0AA0 3VA5460-6EC31-0AA0 3VA5460-7EC31-0AA0<br />

TM240 ATAM<br />

450 3VA5445-5EF31-0AA0 3VA5445-6EF31-0AA0 3VA5445-7EF31-0AA0<br />

500 3VA5450-5EF31-0AA0 3VA5450-6EF31-0AA0 3VA5450-7EF31-0AA0<br />

600 3VA5460-5EF31-0AA0 3VA5460-6EF31-0AA0 3VA5460-7EF31-0AA0<br />

3VA54 600A Frame, 4-Pole Frame, Thermal-Magnetic Trip Unit<br />

Cont.<br />

Ampere<br />

Rating<br />

M-Interrupting Class<br />

(MLAS)<br />

H-Interrupting Class<br />

(HLAS)<br />

C-Interrupting Class<br />

(CLAS)<br />

Catalog Number Catalog Number Catalog Number<br />

TM230 FTAM Unprotected Neutral<br />

450 3VA5445-5EC41-0AA0 3VA5445-6EC41-0AA0 3VA5445-7EC41-0AA0<br />

500 3VA5450-5EC41-0AA0 3VA5450-6EC41-0AA0 3VA5450-7EC41-0AA0<br />

600 3VA5460-5EC41-0AA0 3VA5460-6EC41-0AA0 3VA5460-7EC41-0AA0<br />

TM240 ATAM Unprotected Neutral<br />

450 3VA5445-5EF41-0AA0 3VA5445-6EF41-0AA0 3VA5445-7EF41-0AA0<br />

500 3VA5450-5EF41-0AA0 3VA5450-6EF41-0AA0 3VA5450-7EF41-0AA0<br />

600 3VA5460-5EF41-0AA0 3VA5460-6EF41-0AA0 3VA5460-7EF41-0AA0<br />

TM230 FTAM 100% Neutral<br />

450 3VA5445-5GC41-0AA0 3VA5445-6GC41-0AA0 3VA5445-7GC41-0AA0<br />

500 3VA5450-5GC41-0AA0 3VA5450-6GC41-0AA0 3VA5450-7GC41-0AA0<br />

600 3VA5460-5GC41-0AA0 3VA5460-6GC41-0AA0 3VA5460-7GC41-0AA0<br />

TM240 ATAM 100% Neutral<br />

450 3VA5445-5GF41-0AA0 3VA5445-6GF41-0AA0 3VA5445-7GF41-0AA0<br />

500 3VA5450-5GF41-0AA0 3VA5450-6GF41-0AA0 3VA5450-7GF41-0AA0<br />

600 3VA5460-5GF41-0AA0 3VA5460-6GF41-0AA0 3VA5460-7GF41-0AA0<br />

Dimensions<br />

Shipping Weight<br />

Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg<br />

3VA54 3 6.4 (162) 10.3 (262) 6.7 (170) 11.5 5.2<br />

3VA54 4 8.2 (208) 10.3 (262) 6.7 (170) 15.0 6.8<br />

Interrupting Ratings for 3VA54<br />

Interrupting<br />

Class<br />

Breaker<br />

Type<br />

RMS Symmetrical Amperes (kA)<br />

Volts AC (50/60 Hz)<br />

240<br />

480Y/<br />

277V 480<br />

600Y/<br />

347V 600<br />

Volts DC<br />

250<br />

(2P)<br />

600<br />

(3P)<br />

750<br />

(3P)<br />

750<br />

(4P)<br />

1000<br />

(4P)<br />

M MLAS 85 35 35 18 18 50 50 10 50 10<br />

H HLAS 100 65 65 25 25 85 85 10 85 10<br />

C CLAS 200 100 100 35 35 100 100 10 100 10<br />

Trip Settings for 3VA54<br />

TM230 - FTAM<br />

I n (A) I r(A) I i (A)<br />

450 450 2250 2700 3150 3600 4050 4500<br />

500 500 2500 3000 3500 4000 4500 5000<br />

600 600 3000 3600 4200 4800 5400 6000<br />

TM240 - ATAM<br />

I n (A) I r(A) I i (A)<br />

450 360 2250 2700 3150 3600 4050 4500<br />

500 400 2500 3000 3500 4000 4500 5000<br />

600 480 3000 3600 4200 4800 5400 6000<br />

3VA54 600A 3-Pole<br />

3VA54 600A 4-Pole<br />

Ordering Information<br />

The catalog numbers listed here are<br />

for complete, non-interchangable trip<br />

circuit breakers without lugs.<br />

Order required lugs or connection<br />

technology separately for field<br />

installation.<br />

All 3VA54 thermal-magnetic trip<br />

circuit breakers are UL listed for<br />

reverse feed applications.<br />

For NAVAL rated thermal-magnetic<br />

trip circuit breakers, change the<br />

13th digit of the catalog number<br />

to the number "1". (For example,a<br />

35KA@480VAC, 600A, 3-pole, rated<br />

3VA54 would be catalog number<br />

3VA5460-5EC31-1AA0)<br />

a Available with NAVAL/50C ratings.<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-69


3VA Molded Case Circuit Breakers<br />

3VA64 600A Electronic Trip Circuit Breakers<br />

Revised on 01/31/20<br />

Selection<br />

Ordering Information<br />

3VA64 600A 3-Pole<br />

The catalog numbers listed below are for complete, non-interchangable<br />

trip circuit breakers without lugs.<br />

Order required lugs or connection technology separately for field installation.<br />

All 3VA64 electronic trip circuit breakers are UL listed for reverse feed applications.<br />

3VA64 electronic trip circuit breakers are available with 100% ratings (400A only).<br />

For 100% rated electronic trip circuit breakers, change the 13th digit of the<br />

catalog number to the number "2". (For example, a 35KA @480VAC, 400A,<br />

3-pole, 100% rated 3VA64 would be catalog number 3VA6440-5HL31-2AA0)<br />

Requires the use of copper lugs — see lug table below.<br />

All 3VA6 circuit breakers are certified to UL 489 Supplement SB, are marked<br />

“Naval”, and are suitable for use at 50C.<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

3VA64 600A Frame 3-Pole Electronic Trip Unit<br />

Continuous<br />

Ampere<br />

M-Interrupting Class<br />

(MLAE)<br />

H-Interrupting Class<br />

(HLAE)<br />

C-Interrupting Class<br />

(CLAE)<br />

L-Interrupting Class<br />

(LLAE)<br />

E-Interrupting Class<br />

(ELAE)<br />

Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number<br />

ETU320 LI with dials<br />

400 3VA6440-5HL31-0AA0 3VA6440-6HL31-0AA0 3VA6440-7HL31-0AA0 3VA6440-8HL31-0AA0 —<br />

600 3VA6460-5HL31-0AA0 3VA6460-6HL31-0AA0 3VA6460-7HL31-0AA0 3VA6460-8HL31-0AA0 3VA6460-0HL31-0AA0<br />

ETU330 LIG with dials<br />

400 3VA6440-5HM31-0AA0 3VA6440-6HM31-0AA0 3VA6440-7HM31-0AA0 3VA6440-8HM31-0AA0 —<br />

600 3VA6460-5HM31-0AA0 3VA6460-6HM31-0AA0 3VA6460-7HM31-0AA0 3VA6460-8HM31-0AA0 3VA6460-0HM31-0AA0<br />

ETU350 LSI with dials<br />

400 3VA6440-5HN31-0AA0 3VA6440-6HN31-0AA0 3VA6440-7HN31-0AA0 3VA6440-8HN31-0AA0 —<br />

600 3VA6460-5HN31-0AA0 3VA6460-6HN31-0AA0 3VA6460-7HN31-0AA0 3VA6460-8HN31-0AA0 3VA6460-0HN31-0AA0<br />

ETU550 LSI with LCD<br />

400 3VA6440-5JP31-0AA0 3VA6440-6JP31-0AA0 3VA6440-7JP31-0AA0 3VA6440-8JP31-0AA0 —<br />

600 3VA6460-5JP31-0AA0 3VA6460-6JP31-0AA0 3VA6460-7JP31-0AA0 3VA6460-8JP31-0AA0 —<br />

ETU556 LSI(G Alarm) with LCD<br />

400 3VA6440-5JT31-0AA0 3VA6440-6JT31-0AA0 3VA6440-7JT31-0AA0 3VA6440-8JT31-0AA0 —<br />

600 3VA6460-5JT31-0AA0 3VA6460-6JT31-0AA0 3VA6460-7JT31-0AA0 3VA6460-8JT31-0AA0 —<br />

ETU560 LSIG with LCD<br />

400 3VA6440-5JQ31-0AA0 3VA6440-6JQ31-0AA0 3VA6440-7JQ31-0AA0 3VA6440-8JQ31-0AA0 —<br />

600 3VA6460-5JQ31-0AA0 3VA6460-6JQ31-0AA0 3VA6460-7JQ31-0AA0 3VA6460-8JQ31-0AA0 —<br />

ETU820 LI with LCD and Metering<br />

400 3VA6440-5KL31-0AA0 3VA6440-6KL31-0AA0 3VA6440-7KL31-0AA0 3VA6440-8KL31-0AA0 —<br />

600 3VA6460-5KL31-0AA0 3VA6460-6KL31-0AA0 3VA6460-7KL31-0AA0 3VA6460-8KL31-0AA0 —<br />

ETU830 LIG with LCD and Metering<br />

400 3VA6440-5KM31-0AA0 3VA6440-6KM31-0AA0 3VA6440-7KM31-0AA0 3VA6440-8KM31-0AA0 —<br />

600 3VA6460-5KM31-0AA0 3VA6460-6KM31-0AA0 3VA6460-7KM31-0AA0 3VA6460-8KM31-0AA0 —<br />

ETU850 LSI with LCD and Metering<br />

400 3VA6440-5KP31-0AA0 3VA6440-6KP31-0AA0 3VA6440-7KP31-0AA0 3VA6440-8KP31-0AA0 —<br />

600 3VA6460-5KP31-0AA0 3VA6460-6KP31-0AA0 3VA6460-7KP31-0AA0 3VA6460-8KP31-0AA0 —<br />

ETU856 LSI(G Alarm) with LCD and Metering<br />

400 3VA6440-5KT31-0AA0 3VA6440-6KT31-0AA0 3VA6440-7KT31-0AA0 3VA6440-8KT31-0AA0 —<br />

600 3VA6460-5KT31-0AA0 3VA6460-6KT31-0AA0 3VA6460-7KT31-0AA0 3VA6460-8KT31-0AA0 3VA6460-0KT31-0AA0<br />

ETU860 LSIG with LCD and Metering<br />

400 3VA6440-5KQ31-0AA0 3VA6440-6KQ31-0AA0 3VA6440-7KQ31-0AA0 3VA6440-8KQ31-0AA0 —<br />

600 3VA6460-5KQ31-0AA0 3VA6460-6KQ31-0AA0 3VA6460-7KQ31-0AA0 3VA6460-8KQ31-0AA0 3VA6460-0KQ31-0AA0<br />

7-70<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA64 600A Electronic Trip Circuit Breakers<br />

Revised on 04/30/20<br />

Selection<br />

3VA64 600A 4-Pole<br />

Interrupting Ratings for 3VA64<br />

Interrupting<br />

Class<br />

Dimensions<br />

Breaker<br />

Type<br />

RMS Symmetrical Amperes (kA)<br />

Volts AC (50/60 Hz)<br />

240 480Y/277V 480 600Y/347V 600<br />

M MLAE 100 35 35 18 18<br />

H HLAE 100 65 65 22 22<br />

C CLAE 200 100 100 35 35<br />

L LLAE 200 150 150 50 50<br />

E ELAE — 200 200 100 100<br />

Shipping Weight<br />

Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg<br />

3VA64 3 6.4 (162) 10.3 (262) 6.7 (170) 11.0 5.2<br />

3VA64 4 8.2 (208) 10.3 (262) 6.7 (170) 15.0 6.8<br />

3VA64 600A Frame 4-Pole Electronic Trip Unit<br />

Continuous<br />

Ampere<br />

M-Interrupting Class<br />

(MLAE)<br />

H-Interrupting Class<br />

(HLAE)<br />

C-Interrupting Class<br />

(CLAE)<br />

L-Interrupting Class<br />

(LLAE)<br />

E-Interrupting Class<br />

(ELAE)<br />

Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number<br />

ETU320 LI with dials<br />

400 3VA6440-5HL41-0AA0 3VA6440-6HL41-0AA0 3VA6440-7HL41-0AA0 3VA6440-8HL41-0AA0 —<br />

600 3VA6460-5HL41-0AA0 3VA6460-6HL41-0AA0 3VA6460-7HL41-0AA0 3VA6460-8HL41-0AA0 3VA6460-0HL41-0AA0<br />

ETU330 LIG with dials<br />

400 3VA6440-5HM41-0AA0 3VA6440-6HM41-0AA0 3VA6440-7HM41-0AA0 3VA6440-8HM41-0AA0 —<br />

600 3VA6460-5HM41-0AA0 3VA6460-6HM41-0AA0 3VA6460-7HM41-0AA0 3VA6460-8HM41-0AA0 3VA6460-0HM41-0AA0<br />

ETU350 LSI with dials<br />

400 3VA6440-5HN41-0AA0 3VA6440-6HN41-0AA0 3VA6440-7HN41-0AA0 3VA6440-8HN41-0AA0 —<br />

600 3VA6460-5HN41-0AA0 3VA6460-6HN41-0AA0 3VA6460-7HN41-0AA0 3VA6460-8HN41-0AA0 3VA6460-0HN41-0AA0<br />

ETU550 LSI with LCD<br />

400 3VA6440-5JP41-0AA0 3VA6440-6JP41-0AA0 3VA6440-7JP41-0AA0 3VA6440-8JP41-0AA0 —<br />

600 3VA6460-5JP41-0AA0 3VA6460-6JP41-0AA0 3VA6460-7JP41-0AA0 3VA6460-8JP41-0AA0 —<br />

ETU556 LSI(G Alarm) with LCD<br />

400 3VA6440-5JT41-0AA0 3VA6440-6JT41-0AA0 3VA6440-7JT41-0AA0 3VA6440-8JT41-0AA0 —<br />

600 3VA6460-5JT41-0AA0 3VA6460-6JT41-0AA0 3VA6460-7JT41-0AA0 3VA6460-8JT41-0AA0 —<br />

ETU560 LSIG with LCD<br />

400 3VA6440-5JQ41-0AA0 3VA6440-6JQ41-0AA0 3VA6440-7JQ41-0AA0 3VA6440-8JQ41-0AA0 —<br />

600 3VA6460-5JQ41-0AA0 3VA6460-6JQ41-0AA0 3VA6460-7JQ41-0AA0 3VA6460-8JQ41-0AA0 —<br />

ETU820 LI with LCD and Metering<br />

400 3VA6440-5KL41-0AA0 3VA6440-6KL41-0AA0 3VA6440-7KL41-0AA0 3VA6440-8KL41-0AA0 —<br />

600 3VA6460-5KL41-0AA0 3VA6460-6KL41-0AA0 3VA6460-7KL41-0AA0 3VA6460-8KL41-0AA0 —<br />

ETU830 LIG with LCD and Metering<br />

400 3VA6440-5KM41-0AA0 3VA6440-6KM41-0AA0 3VA6440-7KM41-0AA0 3VA6440-8KM41-0AA0 —<br />

600 3VA6460-5KM41-0AA0 3VA6460-6KM41-0AA0 3VA6460-7KM41-0AA0 3VA6460-8KM41-0AA0 —<br />

ETU850 LSI with LCD and Metering<br />

400 3VA6440-5KP41-0AA0 3VA6440-6KP41-0AA0 3VA6440-7KP41-0AA0 3VA6440-8KP41-0AA0 —<br />

600 3VA6460-5KP41-0AA0 3VA6460-6KP41-0AA0 3VA6460-7KP41-0AA0 3VA6460-8KP41-0AA0 —<br />

ETU856 LSI(G Alarm) with LCD and Metering<br />

400 3VA6440-5KT41-0AA0 3VA6440-6KT41-0AA0 3VA6440-7KT41-0AA0 3VA6440-8KT41-0AA0 —<br />

600 3VA6460-5KT41-0AA0 3VA6460-6KT41-0AA0 3VA6460-7KT41-0AA0 3VA6460-8KT41-0AA0 3VA6460-0KT41-0AA0<br />

ETU860 LSIG with LCD and Metering<br />

400 3VA6440-5KQ41-0AA0 3VA6440-6KQ41-0AA0 3VA6440-7KQ41-0AA0 3VA6440-8KQ41-0AA0 —<br />

600 3VA6460-5KQ41-0AA0 3VA6460-6KQ41-0AA0 3VA6460-7KQ41-0AA0 3VA6460-8KQ41-0AA0 3VA6460-0KQ41-0AA0<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-71


3VA Molded Case Circuit Breakers<br />

3VA64 600A Electronic Trip Circuit Breakers<br />

Revised on 04/30/20<br />

Technical information<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Connections for 75C wire for 3VA54 and 3VA64<br />

Type<br />

Minimum<br />

cable size<br />

Maximum<br />

cable size<br />

Part Number<br />

(kit of 3 lugs)<br />

Part Number<br />

(kit of 4 lugs)<br />

Steel Wrap around (Cu cable only) single cable lugs 1/0 500 kcmil 3VA9473-0JA13 3VA9474-0JA13<br />

Steel Wrap around (Cu cable only)<br />

single cable lugs with control wire tap<br />

1/0 500 kcmil 3VA9473-0JH13 3VA9474-0JH13<br />

Aluminum Body Lug (Cu/Al cable) single cable lugs AWG 1 600 kcmil 3VA9373-0JB13 3VA9374-0JB13<br />

Aluminum body lug with control wire tap<br />

(Cu/Al cable) single cable lugs<br />

AWG 1 600 kcmil 3VA9373-0JG13 3VA9374-0JG13<br />

Aluminum body lug, 2 cables (Cu/Al cable) with<br />

1 extended terminal cover<br />

2/0 600 kcmil 3VA9473-0JJ23 3VA9474-0JJ23<br />

Aluminum body lug, 2 cables (Cu/Al cable) with<br />

control wire tap and 1 extended terminal cover<br />

2/0 600 kcmil 3VA9473-0JC23 3VA9474-0JC23<br />

Distribution lug, 6 Cables (Cu/Al cable) with<br />

1 extended terminal cover<br />

AWG 14 AWG 2 3VA9373-0JF60 3VA9374-0JF60<br />

Copper body lug (Cu cable only) single cable lugs a AWG 1 600 kcmil 3VA9373-0JD13 3VA9374-0JD13<br />

Copper body lug (Cu cable only) with<br />

control wire tap single cable lugs a AWG 1 600 kcmil 3VA9373-0JK13 3VA9374-0JK13<br />

Copper body lug, 2 cables (Cu cable only) with<br />

1 extended terminal cover b 2/0 600 kcmil 3VA9473-0JE23 3VA9474-0JE23<br />

3VA UL Molded Case Circuit Breakers<br />

Copper body lug, 2 cables (Cu cable only)<br />

with control wire tap and 1 extended terminal cover b 2/0 Accessories and 600 Spare kcmil Parts 3VA9473-0JL23 3VA9474-0JL23<br />

a Meets the requirement for 100% rated breakers up to 400A.<br />

b Meets requirement for 100% rated breakers up to 400A,<br />

requires the use of 90 degree wire.<br />

Enclosures for 3VA54 and<br />

3VA64 (3-pole only)<br />

NEMA Type Catalog Number<br />

1 Surface 3VAE6001S<br />

1 Flush 3VAE6001F<br />

3R<br />

3VAE6003R<br />

12 3VAE60012<br />

4X (304)<br />

4X (316)<br />

Neutral<br />

3VAE6004X<br />

3VAE6004X316<br />

HN656ACB<br />

200% Neutral HN678ACB<br />

Trip Settings for 3VA64<br />

ETU320-LI, ETU330-LIG, ETU350-LSI<br />

Continuous<br />

Amperage LI, LIG, LSI LSI LIG<br />

LI, LIG, LSI<br />

4P only<br />

I sd= xIr<br />

I n (Amp) I r(Amp) (L) t ld (sec) (L) I i (Amp) (I) c (Amp) (S) t sd (sec) (S) I g (Amp) (G) I N=xI r (Amp)<br />

400 150 - 400 0.5 - 17 600-4800 1.5 - 10<br />

80 - 400 0.5 - 1 / OFF<br />

0.08 - 0.4<br />

600 250 - 600 0.5 - 15 900-5400 1.5 - 9 120 - 600 0.5 - 1 / OFF<br />

c I i for ETU350 is fixed at the maximum level shown in table.<br />

ETU550-LSI, ETU556 LSI(A), ETU560-LSIG, ETU820-LI, ETU830-LIG, ETU850-LSI, ETU856 LSI(A), ETU860-LSIG<br />

Continuous<br />

Amperage LI, LIG, LSI, LSIG, LSI(G) LSI, LSIG, LSI(G) LIG, LSIG, LSI(G)<br />

4<br />

Internal accessories<br />

Internal accessories<br />

Optional equipment<br />

Auxiliary switch<br />

Auxiliary switch<br />

Leading changeover switch<br />

Alarm switch<br />

Trip alarm switch<br />

<br />

Electrical alarm switch<br />

Auxiliary release<br />

Shunt trip flexible<br />

Shunt trip left<br />

Undervoltage release<br />

Universal release<br />

<br />

ETU/communication<br />

Communication module<br />

Breaker data server<br />

24 V module<br />

Other<br />

Cylinder lock (type Ronis)<br />

UVR x x<br />

UNI x x<br />

Type<br />

LSI 3P with<br />

External CT<br />

b These accessories are for<br />

electronic trip breakers only.<br />

See page 7-81 for internal<br />

accessory part numbers.<br />

LI, LIG, LSI, LSIG,<br />

LSI(G) 4P only<br />

I n (Amp) I r(Amp) (L) t ld (sec) (L) I i (Amp) (I) I sd (Amp) (S) t sd (sec) (S) I g (Amp) (G) t g (G) I N=xI r (Amp) I N (Amp)<br />

400 150 - 400 0.5 - 25 600-4800 240 - 4000<br />

80 - 400<br />

80 - 640 / OFF 80 - 600 / OFF<br />

0.05 - 0.5<br />

0.05 - 0.8<br />

600 250 - 600 0.5 - 15 900-5400 360 - 5400 4/6 Siemens · 04/<strong>2017</strong>120 - 600 120 - 960 / OFF 120 - 600 / OFF<br />

For specific trip settings refer to the Electronic Trip Unit section of the 3VA Systems Manual,<br />

which can be found in the document download center at https://www.siemens.com/download?BTLV_50412<br />

Slot No.:<br />

Type<br />

Type<br />

Type<br />

3-pole<br />

4-pole<br />

25 24 23 22 21 11 12 13 14 15 35 34 33 32 31 25 24 23 22 21 11 12 13 14 15<br />

AUX_HQ x x x x x x x x x x x x x x x x x x x x x x x x x<br />

AUX_HQ_el x x x x x x x x x x x x x x x x x x x x x x x x x<br />

AUX_HP x x x x x x x x x x<br />

x x x x x x x x x x<br />

LCS_HQ<br />

LCS_HQ_el<br />

LCS_HP<br />

TAS_HQ<br />

TAS_HQ_el<br />

TAS_HP<br />

EAS_HQ<br />

EAS_HQ_el<br />

STF<br />

STL<br />

COM060<br />

3VA5 & 3VA6<br />

x<br />

x<br />

x<br />

x<br />

400/600 A<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

3VA5 & 3VA6<br />

400/600 A<br />

600 A 600 A<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

I201_19495<br />

7-72<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA55 800A Electronic Trip Circuit Breakers<br />

Revised on 08/31/20<br />

Selection<br />

3VA55 800A, 2-pole in 3-pole Frame, Thermal-Magnetic Trip Unit<br />

Cont.<br />

Ampere<br />

Rating<br />

M-Interrupting Class<br />

(MMAS)<br />

H-Interrupting Class<br />

(HMAS)<br />

C-Interrupting Class<br />

(CMAS)<br />

Catalog Number Catalog Number Catalog Number<br />

TM230 FTAM<br />

600 3VA5560-5EC62-0AA0 3VA5560-6EC62-0AA0 3VA5560-7EC62-0AA0<br />

700 3VA5570-5EC62-0AA0 3VA5570-6EC62-0AA0 3VA5570-7EC62-0AA0<br />

800 3VA5580-5EC62-0AA0 3VA5580-6EC62-0AA0 3VA5580-7EC62-0AA0<br />

3VA55 800A, 3-pole Frame, Thermal-Magnetic Trip Unit<br />

Cont.<br />

Ampere<br />

Rating<br />

M-Interrupting Class<br />

(MMAS)<br />

H-Interrupting Class<br />

(HMAS)<br />

C-Interrupting Class<br />

(CMAS)<br />

Catalog Number Catalog Number Catalog Number<br />

TM230 FTAM<br />

600 3VA5560-5EC32-0AA0 3VA5560-6EC32-0AA0 3VA5560-7EC32-0AA0<br />

700 3VA5570-5EC32-0AA0 3VA5570-6EC32-0AA0 3VA5570-7EC32-0AA0<br />

800 3VA5580-5EC32-0AA0 3VA5580-6EC32-0AA0 3VA5580-7EC32-0AA0<br />

3VA55 800A, 4-pole Frame, Thermal-Magnetic Trip Unit<br />

Cont.<br />

Ampere<br />

Rating<br />

M-Interrupting Class<br />

(MMAS)<br />

H-Interrupting Class<br />

(HMAS)<br />

C-Interrupting Class<br />

(CMAS)<br />

Catalog Number Catalog Number Catalog Number<br />

TM230 FTAM Unprotected Neutral<br />

600 3VA5560-5EC42-0AA0 3VA5560-6EC42-0AA0 3VA5560-7EC42-0AA0<br />

700 3VA5570-5EC42-0AA0 3VA5570-6EC42-0AA0 3VA5570-7EC42-0AA0<br />

800 3VA5580-5EC42-0AA0 3VA5580-6EC42-0AA0 3VA5580-7EC42-0AA0<br />

TM230 FTAM 100% Neutral<br />

600 3VA5560-5GC42-0AA0 3VA5560-6GC42-0AA0 3VA5560-7GC42-0AA0<br />

700 3VA5570-5GC42-0AA0 3VA5570-6GC42-0AA0 3VA5570-7GC42-0AA0<br />

800 3VA5580-5GC42-0AA0 3VA5580-6GC42-0AA0 3VA5580-7GC42-0AA0<br />

3VA55 800A 3-Pole<br />

Dimensions<br />

Shipping Weight<br />

Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg<br />

3VA55 2(3) 8.3 (210) 12.5 (318) 5.8 (147) 29.3 13.3<br />

3VA55 3 8.3 (210) 12.5 (318) 5.8 (147) 29.4 13.4<br />

3VA55 4 11.1 (280) 12.5 (318) 5.8 (147) 37.4 17.0<br />

Interrupting Ratings for 3VA55<br />

Interrupting<br />

Class<br />

Breaker<br />

Type<br />

RMS Symmetrical Amperes (kA)<br />

Volts AC (50/60 Hz)<br />

240<br />

480Y/<br />

277V 480<br />

600Y/<br />

347V 600<br />

Volts DC<br />

250<br />

(2P)<br />

600<br />

(3P)<br />

750<br />

(3P)<br />

750<br />

(4P)<br />

1000<br />

(4P)<br />

M MMAS 85 35 35 18 18 50 50 50 50 18<br />

H HMAS 100 65 65 25 25 85 85 85 85 25<br />

C CMAS 200 100 100 50 50 100 100 100 100 50<br />

Trip Settings for 3VA55<br />

TM230 - FTAM<br />

I n (Amp) I r(Amp) I i (Amp)<br />

600 600 3000 3600 4200 4800 5400 6000<br />

700 700 3500 4200 4900 5600 6300 7000<br />

800 800 4000 4800 5600 6400 7200 8000<br />

TM240 - ATAM<br />

I n (Amp) I r(Amp) I i (Amp)<br />

600 480 3000 3600 4200 4800 5400 6000<br />

700 560 3500 4200 4900 5600 6300 7000<br />

800 640 4000 4800 5600 6400 7200 8000<br />

3VA55 800A 4-Pole<br />

Ordering Information<br />

The catalog numbers listed here are<br />

for complete, non-interchangable trip<br />

circuit breakers with nut keepers on<br />

both line and load ends.<br />

Order required lugs or connection<br />

technology separately for field<br />

installation.<br />

All 3VA55 thermal-magnetic trip<br />

circuit breakers are UL listed for<br />

reverse feed applications.<br />

For NAVAL rated (3-pole only) thermalmagnetic<br />

trip circuit breakers, change<br />

the 13th digit of the catalog number<br />

to the number "1". (For example, a<br />

35KA@480VAC, 600A, 3-pole, rated<br />

3VA55 would be catalog number<br />

3VA5580-5EC32-1AA0)<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-73


3VA Molded Case Circuit Breakers<br />

3VA65 800A Electronic Trip Circuit Breakers<br />

Revised on 06/30/20<br />

Selection<br />

Ordering Information<br />

3VA65 800A 3-Pole<br />

The catalog numbers listed below are for complete, non-interchangable<br />

trip circuit breakers with nut keepers on both line and load ends.<br />

Order required lugs or connection technology separately for field installation.<br />

All 3VA65 electronic trip circuit breakers are UL listed for reverse feed applications.<br />

3VA65 electronic trip circuit breakers are available with 100% ratings.<br />

For 100% rated electronic trip circuit breakers, change the 13th digit of the<br />

catalog number to the number "2". (For example, a 35KA @480VAC, 600A,<br />

3-pole, 100% rated 3VA65 would be catalog number 3VA6560-5HL32-2AA0)<br />

All 3VA6 circuit breakers are certified to UL 489 Supplement SB, are marked<br />

“Naval”, and are suitable for use at 50C.<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

3VA65 800A, 3-pole Frame, Electronic Trip Unit<br />

Continuous<br />

Ampere<br />

M-Interrupting Class<br />

(MMAE)<br />

H-Interrupting Class<br />

(HMAE)<br />

C-Interrupting Class<br />

(CMAE)<br />

Catalog Number Catalog Number Catalog Number<br />

ETU320 LI with dials<br />

600 3VA6560-5HL32-0AA0 3VA6560-6HL32-0AA0 3VA6560-7HL32-0AA0<br />

800 3VA6580-5HL32-0AA0 3VA6580-6HL32-0AA0 3VA6580-7HL32-0AA0<br />

ETU330 LIG with dials<br />

600 3VA6560-5HM32-0AA0 3VA6560-6HM32-0AA0 3VA6560-7HM32-0AA0<br />

800 3VA6580-5HM32-0AA0 3VA6580-6HM32-0AA0 3VA6580-7HM32-0AA0<br />

ETU350 LSI with dials<br />

600 3VA6560-5HN32-0AA0 3VA6560-6HN32-0AA0 3VA6560-7HN32-0AA0<br />

800 3VA6580-5HN32-0AA0 3VA6580-6HN32-0AA0 3VA6580-7HN32-0AA0<br />

ETU550 LSI with LCD<br />

600 3VA6560-5JP32-0AA0 3VA6560-6JP32-0AA0 3VA6560-7JP32-0AA0<br />

800 3VA6580-5JP32-0AA0 3VA6580-6JP32-0AA0 3VA6580-7JP32-0AA0<br />

ETU556 LSI(G Alarm) with LCD<br />

600 3VA6560-5JT32-0AA0 3VA6560-6JT32-0AA0 3VA6560-7JT32-0AA0<br />

800 3VA6580-5JT32-0AA0 3VA6580-6JT32-0AA0 3VA6580-7JT32-0AA0<br />

ETU560 LSIG with LCD<br />

600 3VA6560-5JQ32-0AA0 3VA6560-6JQ32-0AA0 3VA6560-7JQ32-0AA0<br />

800 3VA6580-5JQ32-0AA0 3VA6580-6JQ32-0AA0 3VA6580-7JQ32-0AA0<br />

ETU820 LI with LCD and Metering<br />

600 3VA6560-5KL32-0AA0 3VA6560-6KL32-0AA0 3VA6560-7KL32-0AA0<br />

800 3VA6580-5KL32-0AA0 3VA6580-6KL32-0AA0 3VA6580-7KL32-0AA0<br />

ETU856 LSI(G Alarm) with LCD and Metering<br />

600 3VA6560-5KT32-0AA0 3VA6560-6KT32-0AA0 3VA6560-7KT32-0AA0<br />

800 3VA6580-5KT32-0AA0 3VA6580-6KT32-0AA0 3VA6580-7KT32-0AA0<br />

ETU860 LSIG with LCD and Metering<br />

600 3VA6560-5KQ32-0AA0 3VA6560-6KQ32-0AA0 3VA6560-7KQ32-0AA0<br />

800 3VA6580-5KQ32-0AA0 3VA6580-6KQ32-0AA0 3VA6580-7KQ32-0AA0<br />

7-74<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA65 800A Electronic Trip Circuit Breakers<br />

Revised on 06/30/20<br />

Selection<br />

Interrupting Ratings for 3VA65<br />

Interrupting<br />

Class<br />

Breaker<br />

Type<br />

RMS Symmetrical Amperes (kA)<br />

Volts AC (50/60 Hz)<br />

240 480Y/277V 480 600Y/347V 600<br />

M MMAE 100 35 35 25 25<br />

H HMAE 150 65 65 35 35<br />

C CMAE 200 100 100 50 50<br />

3VA65 800A 4-Pole<br />

Dimensions<br />

Shipping Weight<br />

Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg<br />

3VA65 3 8.3 (210) 12.5 (318) 5.8 (147) 29.4 13.4<br />

3VA65 4 11.1 (280) 12.5 (318) 5.8 (147) 37.4 17.0<br />

3VA65 800A, 4-pole Frame, Electronic Trip Unit<br />

Continuous<br />

Ampere<br />

M-Interrupting Class<br />

(MMAE)<br />

H-Interrupting Class<br />

(HMAE)<br />

C-Interrupting Class<br />

(CMAE)<br />

Catalog Number Catalog Number Catalog Number<br />

ETU320 LI with dials<br />

600 3VA6560-5HL42-0AA0 3VA6560-6HL42-0AA0 3VA6560-7HL42-0AA0<br />

800 3VA6580-5HL42-0AA0 3VA6580-6HL42-0AA0 3VA6580-7HL42-0AA0<br />

ETU330 LIG with dials<br />

600 3VA6560-5HM42-0AA0 3VA6560-6HM42-0AA0 3VA6560-7HM42-0AA0<br />

800 3VA6580-5HM42-0AA0 3VA6580-6HM42-0AA0 3VA6580-7HM42-0AA0<br />

ETU350 LSI with dials<br />

600 3VA6560-5HN42-0AA0 3VA6560-6HN42-0AA0 3VA6560-7HN42-0AA0<br />

800 3VA6580-5HN42-0AA0 3VA6580-6HN42-0AA0 3VA6580-7HN42-0AA0<br />

ETU550 LSI with LCD<br />

600 3VA6560-5JP42-0AA0 3VA6560-6JP42-0AA0 3VA6560-7JP42-0AA0<br />

800 3VA6580-5JP42-0AA0 3VA6580-6JP42-0AA0 3VA6580-7JP42-0AA0<br />

ETU556 LSI(G Alarm) with LCD<br />

600 3VA6560-5JT42-0AA0 3VA6560-6JT42-0AA0 3VA6560-7JT42-0AA0<br />

800 3VA6580-5JT42-0AA0 3VA6580-6JT42-0AA0 3VA6580-7JT42-0AA0<br />

ETU560 LSIG with LCD<br />

600 3VA6560-5JQ42-0AA0 3VA6560-6JQ42-0AA0 3VA6560-7JQ42-0AA0<br />

800 3VA6580-5JQ42-0AA0 3VA6580-6JQ42-0AA0 3VA6580-7JQ42-0AA0<br />

ETU820 LI with LCD and Metering<br />

600 3VA6560-5KL42-0AA0 3VA6560-6KL42-0AA0 3VA6560-7KL42-0AA0<br />

800 3VA6580-5KL42-0AA0 3VA6580-6KL42-0AA0 3VA6580-7KL42-0AA0<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

ETU856 LSI(G Alarm) with LCD and Metering<br />

600 3VA6560-5KT42-0AA0 3VA6560-6KT42-0AA0 3VA6560-7KT42-0AA0<br />

800 3VA6580-5KT42-0AA0 3VA6580-6KT42-0AA0 3VA6580-7KT42-0AA0<br />

ETU860 LSIG with LCD and Metering<br />

600 3VA6560-5KQ42-0AA0 3VA6560-6KQ42-0AA0 3VA6560-7KQ42-0AA0<br />

800 3VA6580-5KQ42-0AA0 3VA6580-6KQ42-0AA0 3VA6580-7KQ42-0AA0<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-75


3VA Molded Case Circuit Breakers<br />

3VA55 and 3VA65 800A / 3VA66 1000A Electronic Trip Circuit Breakers<br />

Revised on 08/31/20<br />

Technical information<br />

Connections for 75C wire for 3VA55, 3VA65 and 3VA66<br />

Type<br />

Minimum<br />

cable size<br />

Maximum<br />

cable size<br />

Part Number<br />

(kit of 3 lugs)<br />

Part Number<br />

(kit of 4 lugs)<br />

Aluminum body lug, 2 cables (Cu/Al cable) 4/0 600 kcmil 3VA9573-0JB23 3VA9574-0JB23<br />

Aluminum body lug, 2 cables (Cu/Al cable) with control wire tap 4/0 600 kcmil 3VA9573-0JG23 3VA9574-0JG23<br />

Aluminum body lug, 2 cables (Cu/Al cable) with1 extended terminal cover a 400 kcmil 750 kcmil 3VA9673-0JJ24 3VA9674-0JJ24<br />

Aluminum body lug, 2 cables (Cu/Al cable) with control wire tap and<br />

1 extended terminal cover a 400 kcmil 750 kcmil 3VA9673-0JC24 3VA9674-0JC24<br />

Aluminum body lug, 3 cables (Cu/Al cable) 4/0 400 kcmil 3VA9673-0JB32 3VA9674-0JB32<br />

Aluminum body lug, 3 cables (Cu/Al cable) with control wire tap 4/0 400 kcmil 3VA9673-0JG32 3VA9674-0JG32<br />

Aluminum body lug, 3 cables (Cu/Al cable) with 1 extended terminal cover a 500 kcmil 750 kcmil 3VA9673-0JJ34 3VA9674-0JJ34<br />

Aluminum body lug, 3 cables (Cu/Al cable) with control wire tap and<br />

1 extended terminal cover a 500 kcmil 750 kcmil 3VA9673-0JC34 3VA9674-0JC34<br />

Aluminum body lug, 4 cables (Cu/Al cable) with 1 extended terminal cover a 4/0 500 kcmil 3VA9673-0JJ43 3VA9674-0JJ43<br />

Aluminum body lug, 4 cables (Cu/Al cable) with control wire tap and<br />

1 extended terminal cover a 4/0 500 kcmil 3VA9673-0JC43 3VA9674-0JC43<br />

Aluminum body lug, 4 cables (Cu/Al cable) with 1 extended terminal cover a 4/0 600 kcmil 3VA9673-0JJ44 3VA9674-0JJ44<br />

Aluminum body lug, 4 cables (Cu/Al cable) with control wire tap and<br />

1 extended terminal cover a 4/0 600 kcmil 3VA9673-0JC44 3VA9674-0JC44<br />

Copper body lug, 3 cables (Cu/Al cable) a 4/0 400 kcmil 3VA9673-0JD32 3VA9674-0JD32<br />

Copper body lug, 3 cables (Cu/Al cable) with control wire tap a 4/0 400 kcmil 3VA9673-0JK32 3VA9674-0JK32<br />

Copper body lug, 4 cables (Cu/Al cable) with 1 extended terminal cover 4/0 500 kcmil 3VA9673-0JE43 3VA9674-0JE43<br />

Copper body lug, 4 cables (Cu/Al cable) with control wire tap and<br />

1 extended terminal cover<br />

a Meets requirements for 100% rated breakers up to 800A, requires the use of 90 degree wire.<br />

Product not yet released.<br />

4/0 500 kcmil 3VA9673-0JL43 3VA9674-0JL43<br />

3VA UL Molded Case Circuit Breakers<br />

Accessories and Spare Parts<br />

Internal accessories<br />

Internal accessories<br />

Optional equipment<br />

3VA5 & 3VA6<br />

800A & 1000A<br />

3- & 4-pole<br />

1250 A<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Trip Settings for 3VA55<br />

TM230 - FTAM<br />

I n (Amp) I r(Amp) I i (Amp)<br />

600 600 3000 3600 4200 4800 5400 6000<br />

700 700 3500 4200 4900 5600 6300 7000<br />

800 800 4000 4800 5600 6400 7200 8000<br />

Trip Settings for 3VA65 and 3VA66<br />

ETU320-LI, ETU330-LIG, ETU350-LSI<br />

Cont.<br />

Amp LI, LIG, LSI LSI LIG<br />

I n (Amp)<br />

I r(Amp) (L)<br />

t ld (sec)<br />

(L)<br />

I i (Amp) (I)<br />

I sd= xIr<br />

(Amp) (S)<br />

t sd (sec)<br />

(S)<br />

I g (Amp)<br />

(G)<br />

4<br />

LI, LIG, LSI<br />

4P only<br />

I N=xI r<br />

(Amp)<br />

600 240 - 600 0.5 - 17 900 - 7200 1.5 - 12 0 - 0.4 120 - 600 0.2 - 1.0<br />

800 320 - 800 0.5 - 17 1200 - 8000 1.5 - 10 0 - 0.4 160 - 800 0.2 - 1.0<br />

1000 400 - 1000 0.5 - 17 1500 - 10000 1.5 - 10 0 - 0.4 200 - 1000 0.2 - 1.0<br />

Auxiliary switch<br />

Auxiliary switch<br />

Type<br />

LCS_HQ<br />

Leading changeover switch LCS_HQ_el<br />

LCS_HP<br />

Alarm switch<br />

Type<br />

TAS_HQ<br />

Trip alarm switch<br />

TAS_HQ_el<br />

TAS_HP<br />

EAS_HQ<br />

Electrical alarm switch (3VA6)<br />

EAS_HQ_el<br />

SAS_HQ<br />

Electrical alarm switch<br />

SAS_HQ_el<br />

Auxiliary release<br />

Type<br />

Shunt trip flexible<br />

STF<br />

STL<br />

Shunt trip left<br />

STL (EI)<br />

Residual current release<br />

RCR<br />

Undervoltage release<br />

UVR<br />

Universal release<br />

UNI<br />

<br />

ETU/communication<br />

Type<br />

Communication module 3VA server COM060<br />

24 V module<br />

Other<br />

Cylinder lock (type Ronis)<br />

Slot No.:<br />

AUX_HQ<br />

AUX_HQ_el<br />

AUX_HP<br />

24 23 22 21 11 12 13 14 15 16<br />

x x x x x x x x<br />

x x x x<br />

x x x x<br />

x x x x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

Internal Booster<br />

x x<br />

x<br />

x<br />

x<br />

x x<br />

x x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

x<br />

ETU550-LSI, ETU556 LSI(A), ETU560-LSIG, ETU820-LI, ETU856 LSI(A), ETU860-LSIG<br />

Cont. Amp LI, LIG, LSI, LSIG, LSI(G) LSI, LSIG, LSI(G) LIG, LSIG, LSI(G)<br />

LSI 3P with<br />

External CT<br />

LI, LIG, LSI, LSIG,<br />

LSI(G) 4P only<br />

I n (Amp) I r(Amp) (L) t ld (sec) (L) I i (Amp) (I) I sd (Amp) (S) t sd (sec) (S) I g (Amp) (G) t g (G) I N=xI r (Amp) I N (Amp)<br />

600 240 - 600 0.5 - 25 900 - 7200 360 - 7200 0.05 - 0.5 120 - 600 0.05 - 0.8 120 - 960 120 - 600<br />

800 320 - 800 0.5 - 25 1200 - 8000 480 - 8000 0.05 - 0.5 160 - 800 0.05 - 0.8 160 - 1280 160 - 800<br />

1000 400 - 1000 0.5 - 25 1500 - 10000 600 - 10000 0.05 - 0.5 200 - 1000 0.05 - 0.8 200 - 1600 200 - 1000<br />

For specific trip settings refer to the Electronic Trip Unit section of the 3VA Systems Manual,<br />

which can be found in the document download center at https://www.siemens.com/download?BTLV_50412<br />

7-76<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

4/6 Siemens · 04/<strong>2017</strong>


3VA Molded Case Circuit Breakers<br />

3VA66 1000A Electronic Trip Circuit Breakers<br />

Revised on 06/30/20<br />

Selection<br />

Ordering Information<br />

The catalog numbers listed below are for complete, non-interchangable<br />

trip circuit breakers with nut keepers on both line and load ends.<br />

Order required lugs or connection technology separately for field installation.<br />

All 3VA66 electronic trip circuit breakers are UL listed for reverse feed applications.<br />

All 3VA6 circuit breakers are certified to UL 489 Supplement SB, are marked<br />

“Naval”, and are suitable for use at 50C.<br />

3VA66 800A 3-Pole<br />

3VA66 1000A, 3-pole Frame, Electronic Trip Unit<br />

Continuous<br />

Ampere<br />

M-Interrupting Class<br />

(MMNAE)<br />

H-Interrupting Class<br />

(HMNAE)<br />

C-Interrupting Class<br />

(CMNAE)<br />

Catalog Number Catalog Number Catalog Number<br />

ETU320 LI with dials<br />

1000 3VA6610-5HL32-0AA0 3VA6610-6HL32-0AA0 3VA6610-7HL32-0AA0<br />

ETU330 LIG with dials<br />

1000 3VA6610-5HM32-0AA0 3VA6610-6HM32-0AA0 3VA6610-7HM32-0AA0<br />

ETU350 LSI with dials<br />

1000 3VA6610-5HN32-0AA0 3VA6610-6HN32-0AA0 3VA6610-7HN32-0AA0<br />

ETU550 LSI with LCD<br />

1000 3VA6610-5JP32-0AA0 3VA6610-6JP32-0AA0 3VA6610-7JP32-0AA0<br />

ETU556 LSI(G Alarm) with LCD<br />

1000 3VA6610-5JT32-0AA0 3VA6610-6JT32-0AA0 3VA6610-7JT32-0AA0<br />

ETU560 LSIG with LCD<br />

1000 3VA6610-5JQ32-0AA0 3VA6610-6JQ32-0AA0 3VA6610-7JQ32-0AA0<br />

ETU820 LI with LCD and Metering<br />

1000 3VA6610-5KL32-0AA0 3VA6610-6KL32-0AA0 3VA6610-7KL32-0AA0<br />

ETU856 LSI(G Alarm) with LCD and Metering<br />

1000 3VA6610-5KT32-0AA0 3VA6610-6KT32-0AA0 3VA6610-7KT32-0AA0<br />

ETU860 LSIG with LCD and Metering<br />

1000 3VA6610-5KQ32-0AA0 3VA6610-6KQ32-0AA0 3VA6610-7KQ32-0AA0<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-77


3VA Molded Case Circuit Breakers<br />

3VA66 1000A Electronic Trip Circuit Breakers<br />

Revised on 06/30/20<br />

Selection<br />

Interrupting Ratings for 3VA66<br />

Interrupting<br />

Class<br />

Breaker<br />

Type<br />

RMS Symmetrical Amperes (kA)<br />

Volts AC (50/60 Hz)<br />

240 480Y/277V 480 600Y/347V 600<br />

M MMNAE 100 35 35 25 25<br />

H HMNAE 150 65 65 35 35<br />

C CMNAE 200 100 100 50 50<br />

3VA66 800A 4-Pole<br />

Dimensions<br />

Shipping Weight<br />

Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg<br />

3VA66 3 8.3 (210) 12.5 (318) 5.8 (147) 29.4 13.4<br />

3VA66 4 11.1 (280) 12.5 (318) 5.8 (147) 37.4 17.0<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

3VA66 1000A, 4-pole Frame, Electronic Trip Unit<br />

Continuous<br />

Ampere<br />

M-Interrupting Class<br />

(MMNAE)<br />

H-Interrupting Class<br />

(HMNAE)<br />

C-Interrupting Class<br />

(CMNAE)<br />

Catalog Number Catalog Number Catalog Number<br />

ETU320 LI with dials<br />

1000 3VA6610-5HL42-0AA0 3VA6610-6HL42-0AA0 3VA6610-7HL42-0AA0<br />

ETU330 LIG with dials<br />

1000 3VA6610-5HM42-0AA0 3VA6610-6HM42-0AA0 3VA6610-7HM42-0AA0<br />

ETU350 LSI with dials<br />

1000 3VA6610-5HN42-0AA0 3VA6610-6HN42-0AA0 3VA6610-7HN42-0AA0<br />

ETU550 LSI with LCD<br />

1000 3VA6610-5JP42-0AA0 3VA6610-6JP42-0AA0 3VA6610-7JP42-0AA0<br />

ETU556 LSI(G Alarm) with LCD<br />

1000 3VA6610-5JT42-0AA0 3VA6610-6JT42-0AA0 3VA6610-7JT42-0AA0<br />

ETU560 LSIG with LCD<br />

1000 3VA6610-5JQ42-0AA0 3VA6610-6JQ42-0AA0 3VA6610-7JQ42-0AA0<br />

ETU820 LI with LCD and Metering<br />

1000 3VA6610-5KL42-0AA0 3VA6610-6KL42-0AA0 3VA6610-7KL42-0AA0<br />

ETU856 LSI(G Alarm) with LCD and Metering<br />

1000 3VA6610-5KT42-0AA0 3VA6610-6KT42-0AA0 3VA6610-7KT42-0AA0<br />

ETU860 LSIG with LCD and Metering<br />

1000 3VA6610-5KQ42-0AA0 3VA6610-6KQ42-0AA0 3VA6610-7KQ42-0AA0<br />

7-78<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA Molded Case Switch and Motor Circuit Protector<br />

Revised on 10/15/20<br />

Selection<br />

Breaking capacity (the SCCR rating) is the<br />

maximum permissible short circuit current<br />

at the installation location of the MCS in<br />

combination with an appropriate overload<br />

protective device.<br />

Magnetic switch<br />

Electronic Trip Unit switch<br />

Molded Case Switch Magnetic<br />

Frame<br />

(Breaker<br />

Type)<br />

3VA51<br />

(HEAS)<br />

Max.<br />

Ampere<br />

Rating<br />

2-Pole<br />

3-Pole<br />

Short-Circuit<br />

Current Rating (AC)<br />

Short-Circuit<br />

Current Rating (DC)<br />

Catalog Number Catalog Number 240V 480V 600V 125V 250V b 500V c 600V c<br />

Instantaneous<br />

short circuit<br />

protection<br />

100 3VA5110-1BB21-0AA0 3VA5110-1BB31-0AA0 150k 65k 25k a 30k 100k 100k — 1600 A<br />

Catalog Number Catalog Number 240V 480V 600V 250V 500V b 600V c 750V c<br />

3VA52<br />

(HFAS)<br />

3VA53<br />

(HJAS)<br />

3VA54<br />

(HLAS)<br />

3VA55<br />

(HMAS)<br />

150 3VA5215-0BB61-0AA0 3VA5215-0BB31-0AA0 100k 65k 25k 85k 85k — 85k 2400 A<br />

250 3VA5225-0BB61-0AA0 3VA5225-0BB31-0AA0 100k 65k 25k 85k 85k — 85k 2500 A<br />

400 3VA5340-0BB61-0AA0 3VA5340-0BB31-0AA0 100k 65k 25k 85k 85k 85k 10k 6000 A<br />

600 3VA5460-0BB61-0AA0 3VA5460-0BB31-0AA0 100k 65k 25k 85k 85k 85k 10k 6000 A<br />

800 3VA5580-0BB61-0AA0 3VA5580-0BB31-0AA0 100k 65k 25k 85k 85k 85k 85k 8000 A<br />

Frame<br />

(Breaker<br />

Type)<br />

3VA52<br />

(CFAS)<br />

3VA53<br />

(CJAS)<br />

3VA54<br />

(CLAS)<br />

3VA55<br />

(CMAS)<br />

Max.<br />

Short-Circuit<br />

Short-Circuit<br />

Instantaneous<br />

Ampere<br />

2-Pole<br />

3-Pole<br />

Current Rating (AC) Current Rating (DC)<br />

short circuit<br />

Rating Catalog Number Catalog Number 240V 480V 600V 250V 500V b 600V c 750V c protection<br />

100 3VA5210-1BB61-0AA0 3VA5210-1BB31-0AA0 200k 100k 35k 100k 100k — 100k 2500 A<br />

150 3VA5215-1BB61-0AA0 3VA5215-1BB31-0AA0 200k 100k 35k 100k 100k — 100k 2400 A<br />

250 3VA5225-1BB61-0AA0 3VA5225-1BB31-0AA0 200k 100k 35k 100k 100k — 100k 2500 A<br />

400 3VA5340-1BB61-0AA0 3VA5340-1BB31-0AA0 200k 100k 35k 100k 100k 100k 10k 6000 A<br />

600 3VA5460-1BB61-0AA0 3VA5460-1BB31-0AA0 200k 100k 35k 100k 100k 100k 10k 6000 A<br />

800 3VA5580-1BB61-0AA0 3VA5580-1BB31-0AA0 100k 100k 50k 100k 100k 100k 100k 8000 A<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Molded Case Switch Electronic<br />

Frame<br />

(Breaker<br />

Type)<br />

3VA63<br />

(CJAE)<br />

3VA64<br />

(CLAE)<br />

Max.<br />

Ampere<br />

Rating<br />

2-Pole<br />

3-Pole<br />

Short-Circuit Current<br />

Rating<br />

Catalog Number Catalog Number 240V 480V 600V<br />

Instantaneous<br />

short circuit<br />

protection<br />

400 — 3VA6340-1BB31-0AA0 200k 100k 35k 5600 A<br />

600 — 3VA6460-1BB31-0AA0 200k 100k 35k 5400 A<br />

a Rated at 600 Y/347 V AC.<br />

b Two poles in series.<br />

c Three poles in series.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-79


3VA Molded Case Circuit Breakers<br />

3VA Molded Case Switch and Motor Circuit Protector<br />

Revised on 06/30/20<br />

Selection<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Motor circuit protector TM120M AM c<br />

Frame<br />

(Breaker<br />

Type)<br />

3VA51<br />

(HEAP)<br />

3VA52<br />

(HFAP)<br />

3VA53<br />

(HJAP)<br />

Maximum<br />

Ampere<br />

Rating<br />

3-Pole<br />

Catalog Number<br />

Instantaneous<br />

short circuit<br />

protection<br />

1 3VA5181-1MU31-0AA0 3 ... 7<br />

3VA5181-1MH31-0AA0 5 ... 12<br />

2 3VA5102-1MU31-0AA0 6 ... 14<br />

3VA5102-1MH31-0AA0 10 ... 24<br />

3 3VA5103-1MU31-0AA0 9 ... 21<br />

3VA5103-1MH31-0AA0 15 ... 36<br />

5 3VA5105-1MU31-0AA0 15 ... 35<br />

3VA5105-1MH31-0AA0 25 ... 60<br />

7 3VA5107-1MU31-0AA0 21 ... 49<br />

3VA5107-1MH31-0AA0 35 ... 84<br />

10 3VA5191-1MU31-0AA0 30 ... 70<br />

3VA5191-1MH31-0AA0 50 ... 120<br />

15 3VA5195-1MU31-0AA0 45 ... 105<br />

3VA5195-1MH31-0AA0 75 ... 180<br />

25 3VA5125-1MU31-0AA0 75 ... 175<br />

3VA5125-1MH31-0AA0 125 ... 300<br />

30 3VA5130-1MU31-0AA0 90 ... 210<br />

3VA5130-1MH31-0AA0 150 ... 360<br />

40 3VA5140-1MU31-0AA0 120 ... 280<br />

3VA5140-1MH31-0AA0 200 ... 480<br />

50 3VA5150-1MU31-0AA0 150 ... 350<br />

3VA5150-1MH31-0AA0 250 ... 600<br />

70 3VA5170-1MU31-0AA0 210 ... 490<br />

3VA5170-1MH31-0AA0 350 ... 840<br />

80 3VA5180-1MU31-0AA0 240 ... 560<br />

3VA5180-1MH31-0AA0 400 ... 960<br />

90 3VA5190-1MU31-0AA0 270 ... 630<br />

3VA5190-1MH31-0AA0 450 ... 1080<br />

100 3VA5110-1MU31-0AA0 300 ... 700<br />

3VA5110-1MH31-0AA0 500 ... 1200<br />

110 3VA5111-1MU31-0AA0 330 ... 770<br />

3VA5111-1MH31-0AA0 550 ... 1320<br />

125 3VA5112-1MU31-0AA0 375 ... 875<br />

3VA5112-1MH31-0AA0 625 ... 1500<br />

150 3VA5215-0MU31-0AA0 450 ... 900<br />

3VA5215-0MH31-0AA0 900 ... 1800<br />

200 3VA5220-0MU31-0AA0 600 ... 1200<br />

3VA5220-0MH31-0AA0 1200 ... 2400<br />

250 3VA5225-0MU31-0AA0 750 ... 900<br />

3VA5225-0MH31-0AA0 1250 ... 2500<br />

250 3VA5325-0MU31-0AA0 750 ... 1500<br />

3VA5325-0MH31-0AA0 1500 ... 3000<br />

Interrupting Ratings<br />

Motor circuit protector ETU310M b<br />

3VA61<br />

(CDAR)<br />

3VA62<br />

(CFAR-Y)<br />

3VA63<br />

(CJAR)<br />

3VA64<br />

(CLAR)<br />

3VA65<br />

(CMAR)<br />

RMS Symmetrical Amperes (kA)<br />

Volts AC (50/60 Hz)<br />

Volts DC<br />

Frame<br />

Breaker<br />

Type 240 480<br />

600Y/<br />

347V 600 125 (1P) 250 (2P) 500 d (3P) 600 (3P)<br />

3VA51 HEAP 150 65 25 — 30 100 100 —<br />

3VA52<br />

HFAP 100 65 25 25 85 85<br />

CFAP 200 100 35 35 100 100<br />

3VA53<br />

HJAP 100 65 25 25 — — — —<br />

CHAP 200 100 35 35 — — — —<br />

3VA54<br />

HLAP 100 65 25 25 — — — —<br />

CLAP 200 100 35 35 — — — —<br />

3VA55<br />

HMAP 100 65 25 — — — — —<br />

CMAP 100 100 50 — — — — —<br />

3VA61 CDAR 200 100 35 35 — — — —<br />

3VA62 CFAR 200 100 35 35 — — — —<br />

3VA63 CJAR 200 100 35 35 — — — —<br />

3VA64 CLAR 200 100 35 35 — — — —<br />

3VA65 CMAR 200 100 42 — — — — —<br />

Motor circuit protector TM120M AM b<br />

Frame<br />

(Breaker<br />

Type)<br />

3VA54<br />

(HLAP<br />

3VA55<br />

(HMAP)<br />

3VA52<br />

(CFAP)<br />

3VA53<br />

(CJAP)<br />

3VA54<br />

(CLAP)<br />

3VA55<br />

(CMAP)<br />

Maximum<br />

Ampere<br />

Rating<br />

3-Pole<br />

Catalog Number<br />

Instantaneous<br />

short circuit<br />

protection<br />

400 3VA5440-0MU31-0AA0 750 ... 1500<br />

3VA5440-0MH31-0AA0 1200 ... 2400<br />

500 3VA5450-0MU31-0AA0 1500 ... 3000<br />

3VA5450-0MH31-0AA0 3000 ... 6000<br />

600 3VA5460-0MU31-0AA0 1800 ... 3600<br />

3VA5460-0MH31-0AA0 3000 ... 6000<br />

600 3VA5560-0MH31-0AA0 4800 ... 9600<br />

150 3VA5215-1MU31-0AA0 450 ... 900<br />

3VA5215-1MH31-0AA0 900 ... 1800<br />

200 3VA5220-1MU31-0AA0 600 ... 1200<br />

3VA5220-1MH31-0AA0 1200 ... 2400<br />

250 3VA5225-1MH31-0AA0 750 ... 900<br />

3VA5225-1MU31-0AA0 1250 ... 2500<br />

250 3VA5325-1MU31-0AA0 750 ... 1500<br />

3VA5325-1MH31-0AA0 1500 ... 3000<br />

400 3VA5440-1MU31-0AA0 750 ... 1500<br />

3VA5440-1MH31-0AA0 2400 ... 4800<br />

500 3VA5450-1MU31-0AA0 1500 ... 3000<br />

3VA5450-1MH31-0AA0 3000 ... 6000<br />

600 3VA5460-1MU31-0AA0 1500 ... 3000<br />

3VA5460-1MH31-0AA0 3000 ... 6000<br />

600 3VA5560-1MH31-0AA0 4800 ... 9600<br />

25 3VA6125-1MS31-0AA0 75 ... 375<br />

30 3VA6130-1MS31-0AA0 90 ... 450<br />

40 3VA6140-1MS31-0AA0 120 ... 600<br />

50 3VA6150-1MS31-0AA0 150 ... 750<br />

70 3VA6170-1MS31-0AA0 210 ... 1050<br />

80 3VA6180-1MS31-0AA0 240 ... 1200<br />

90 3VA6190-1MS31-0AA0 270 ... 1350<br />

100 3VA6110-1MS31-0AA0 300 ... 1500<br />

110 3VA6211-1MS31-0AA0 330 ... 1650<br />

125 3VA6212-1MS31-0AA0 375 ... 1875<br />

150 3VA6215-1MS31-0AA0 450 ... 2250<br />

200 3VA6220-1MS31-0AA0 600 ... 2400<br />

200 3VA6320-1MS31-0AA0 600 ... 3000<br />

250 3VA6325-1MS31-0AA0 750 ... 3750<br />

400 3VA6440-1MS31-0AA0 1200 ... 5200<br />

500 3VA6450-1MS31-0AA0 1500 ... 6000<br />

800 3VA6580-1MS31-0AA0 2400 ... 12000<br />

Motor<br />

Circuit<br />

Protector<br />

a Rated at 600 Y/347 V AC.<br />

b SCCR is 100kA at 480 V. SCCR rating is the maximum<br />

permissible short circuit current of the MCP in combination<br />

with an appropriate overload protection device.<br />

c SCCR is 65kA at 480 V. SCCR rating is the maximum<br />

permissible short circuit current of the MCP in combination<br />

with an appropriate overload protection device.<br />

d 2 poles required for 500VDC for breaker types HFAP<br />

and CFAP.<br />

7-80<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA Internal Accessories<br />

Revised on 02/28/19<br />

Selection<br />

Internal Accessories<br />

Auxiliary and Alarm Switches<br />

Switch<br />

Type<br />

Auxiliary Switch<br />

(AUX)<br />

Leading Changeover<br />

Switch (LCS)<br />

Trip Alarm Switch<br />

(TAS)<br />

Electronic Alarm<br />

(EAS)<br />

Shunt Trips<br />

Catalog Number<br />

HP High Power<br />

(2 slots)<br />

HQ Compact<br />

(1 slot)<br />

HQ Electronic a<br />

(1 slot)<br />

3VA9978-0AA11 3VA9978-0AA12 3VA9978-0AA13<br />

3VA9978-0AA21 3VA9978-0AA22 3VA9978-0AA23<br />

3VA9978-0AB11 3VA9978-0AB12 3VA9978-0AB13<br />

— 3VA9978-0AB22 3VA9978-0AB23<br />

Catalog Number<br />

(3 slots)<br />

380 ... 600 — 3VA9978-0BL20<br />

— 12 3VA9978-0BL10<br />

24 24 ... 30 3VA9978-0BL30<br />

48 ... 60 — 3VA9978-0BL31<br />

110 ... 127 110 ... 127 3VA9978-0BL32<br />

208 ... 277 220 ... 250 3VA9978-0BL33<br />

Type VAC 50/60 Hz VDC<br />

Shunt Trip Left<br />

(STL)<br />

(STF) b 208 ... 277 — 3VA9978-0BA23<br />

24 — 3VA9978-0BA20<br />

48 ... 60 — 3VA9978-0BA21<br />

Shunt Trip Flexible 110 ... 127 — 3VA9978-0BA22<br />

380 ... 500 — 3VA9978-0BA24<br />

600 — 3VA9978-0BA25<br />

Undervoltage Release<br />

Undervoltage Release<br />

(UVR)<br />

— 12 3VA9978-0BB10<br />

— 24 3VA9978-0BB11<br />

— 48 3VA9978-0BB12<br />

— 125 ... 127 3VA9978-0BB14<br />

— 250 3VA9978-0BB16<br />

24 — 3VA9978-0BB20<br />

120 ... 127 — 3VA9978-0BB24<br />

208 ... 230 — 3VA9978-0BB25<br />

440 ... 480 — 3VA9978-0BB27<br />

Universal Release (Undervoltage and Shunt trip)<br />

Universal Release<br />

(UNI)<br />

— 12 3VA9978-0BD11<br />

— 24 3VA9978-0BD12<br />

— 48 3VA9978-0BD13<br />

Auxiliary switches and<br />

alarm switches HQ<br />

AUX LCS TAS EAS<br />

Shunt trip left<br />

STL<br />

Auxiliary switches and<br />

alarm switches HP<br />

AUX LCS TAS<br />

Undervoltage<br />

releases UVR<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Time-delay Device for Undervoltage Release<br />

Type VAC 50/60 Hz VDC Delay Time Catalog Number<br />

230 230 Fixed – 100ms minimum 3VA9978-0BF22<br />

Time-delay Device<br />

— 24 Fixed – 100ms minimum 3VA9978-0BF23<br />

Universal<br />

release UNI<br />

Time-delay device<br />

for undervoltage<br />

releases<br />

a Use only with 3VA6.<br />

b Shunt trip flexible can be used in the left pocket of the<br />

3VA5 breakers. They can be used in the left or right<br />

pocket of the 3VA6 breakers.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-81


3VA Molded Case Circuit Breakers<br />

3VA Manual Operators<br />

Revised on 10/15/20<br />

Selection<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Front Mounted Rotary Operator<br />

Degree of protection NEMA 1<br />

3VA6<br />

150A<br />

250A<br />

3VA5<br />

3VA6<br />

400A<br />

600A<br />

3VA5<br />

3VA6<br />

800A<br />

1000A<br />

Type<br />

Color<br />

3VA5<br />

125A<br />

3VA5<br />

250A<br />

Catalog Number<br />

Standard without illumination kit Gray u — — — — 3VA9137-0EK11<br />

— u u — — 3VA9277-0EK11<br />

— — — u — 3VA9447-0EK11<br />

— — — — u 3VA9677-0EK11<br />

Standard with illumination kit Gray u — — — — 3VA9137-0EK13<br />

— u u — — 3VA9277-0EK13<br />

— — — u — 3VA9447-0EK13<br />

EMERGENCY-OFF<br />

Yellow-Red u — — — — 3VA9137-0EK15<br />

without illumination kit<br />

— u u — — 3VA9277-0EK15<br />

— — — u — 3VA9447-0EK15<br />

— — — — u 3VA9677-0EK15<br />

EMERGENCY-OFF<br />

Yellow-Red u — — — — 3VA9137-0EK17<br />

with illumination kit<br />

— u u — — 3VA9277-0EK17<br />

— — — u — 3VA9447-0EK17<br />

Standard with door interlock Gray u — — — — 3VA9137-0EK21<br />

— u u — — 3VA9277-0EK21<br />

— — — u — 3VA9447-0EK21<br />

— — — — u 3VA9677-0EK21<br />

Standard with door interlock,<br />

Gray u — — — — 3VA9137-0EK23<br />

with illumination kit<br />

— u u — — 3VA9277-0EK23<br />

— — — u — 3VA9447-0EK23<br />

EMERGENCY-OFF<br />

Yellow-Red u — — — — 3VA9137-0EK25<br />

with door interlock<br />

— u u — — 3VA9277-0EK25<br />

— — — u — 3VA9447-0EK25<br />

— — — — u 3VA9677-0EK25<br />

EMERGENCY-OFF with door interlock, Yellow-Red u — — — — 3VA9137-0EK27<br />

with illumination kit<br />

— u u — — 3VA9277-0EK27<br />

— — — u — 3VA9447-0EK27<br />

Standard with door interlock,<br />

Gray u — — — — 3VA9137-0EK31<br />

with door open function<br />

— u u — — 3VA9277-0EK31<br />

— — — u — 3VA9447-0EK31<br />

— — — — u 3VA9677-0EK31<br />

Standard with door interlock,<br />

Gray u — — — — 3VA9137-0EK33<br />

with door open function,<br />

with illumination kit<br />

— u u — — 3VA9277-0EK33<br />

— — — u — 3VA9447-0EK33<br />

EMERGENCY-OFF with door interlock, Yellow-Red u — — — — 3VA9137-0EK35<br />

with door open function<br />

— u u — — 3VA9277-0EK35<br />

— — — u — 3VA9447-0EK35<br />

— — — — u 3VA9677-0EK35<br />

EMERGENCY-OFF with door interlock, Yellow-Red u — — — — 3VA9137-0EK37<br />

with door open function,<br />

with illumination kit<br />

— u u — — 3VA9277-0EK37<br />

— — — u — 3VA9447-0EK37<br />

7-82<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA Manual Operators<br />

Revised on 08/31/20<br />

Selection<br />

Door Mounted Rotary Operator a<br />

Degree of protection<br />

Type 1, 12, 3R and 4X<br />

NFPA-79<br />

Supplementary<br />

Handles<br />

Type<br />

Side Mounted Rotary Operator a<br />

n Without mounting plate<br />

n Rotary operator with shaft 300 mm<br />

n Handle with masking plate 75 x 75 mm<br />

n Degree of protection Type 1, 12, 3R, 4X<br />

n With mounting plate<br />

n Rotary operator with short shaft<br />

n Handle with masking plate 75 x 75 mm<br />

n Degree of protection Type 1, 12, 3R, 4X<br />

Side<br />

Mounted<br />

Rotary<br />

Operator<br />

Door<br />

Interlock<br />

a Lockable with up to three padlock hasps.<br />

Color<br />

3VA5<br />

125A<br />

3VA5<br />

250A<br />

3VA6<br />

150A<br />

250A<br />

3VA5<br />

3VA6<br />

400A<br />

600A<br />

3VA5<br />

3VA6<br />

800A<br />

1000A<br />

Catalog Number<br />

Standard Gray u — — — — 3VA9137-0FK21<br />

— u u — — 3VA9277-0FK21<br />

— — — u — 3VA9447-0FK21<br />

— — — — u 3VA9677-0FK21<br />

Standard with illumination kit Gray u — — — — 3VA9137-0FK23<br />

— u u — — 3VA9277-0FK23<br />

— — — u — 3VA9447-0FK23<br />

— — — — u 3VA9677-0FK23<br />

EMERGENCY-OFF<br />

EMERGENCY-OFF<br />

with illumination kit<br />

Standard with door interlock,<br />

with open door function<br />

Standard with door interlock,<br />

with open door function<br />

with illumination kit<br />

Yellow-<br />

Red<br />

Yellow-<br />

Red<br />

u — — — — 3VA9137-0FK25<br />

— u u — — 3VA9277-0FK25<br />

— — — u — 3VA9447-0FK25<br />

— — — — u 3VA9677-0FK25<br />

u — — — — 3VA9137-0FK27<br />

— u u — — 3VA9277-0FK27<br />

— — — u — 3VA9447-0FK27<br />

— — — — u 3VA9677-0FK27<br />

Gray u — — — — 3VA9137-0FK31<br />

— u u — — 3VA9277-0FK31<br />

— — — u — 3VA9447-0FK31<br />

— — — — u 3VA9677-0FK31<br />

Gray u — — — — 3VA9137-0FK33<br />

— u u — — 3VA9277-0FK33<br />

— — — u — 3VA9447-0FK33<br />

— — — — u 3VA9677-0FK33<br />

EMERGENCY-OFF with door Yellow- u — — — — 3VA9137-0FK35<br />

interlock, with open door function Red<br />

— u u — — 3VA9277-0FK35<br />

— — — u — 3VA9447-0FK35<br />

— — — — u 3VA9677-0FK35<br />

EMERGENCY-OFF with door Yellow- u — — — — 3VA9137-0FK37<br />

interlock, with open door<br />

Red<br />

— u u — — 3VA9277-0FK37<br />

function, with illumination kit<br />

— — — u — 3VA9447-0FK37<br />

— — — — u 3VA9677-0FK37<br />

Standard Gray u — — — — 3VA9137-0GC01<br />

— u u — — 3VA9477-0GC01<br />

— — — u — 3VA9477-0GC11<br />

— — — — u 3VA9677-0GC01<br />

EMERGENCY-OFF<br />

Yellow-<br />

Red<br />

u — — — — 3VA9137-0GC05<br />

— u u — — 3VA9477-0GC05<br />

— — — u — 3VA9477-0GC15<br />

— — — — u 3VA9677-0GC05<br />

Standard Gray u — — — — 3VA9137-0PK11<br />

— u u — — 3VA9277-0PK11<br />

Standard with<br />

illumination kit<br />

Gray u — — — — 3VA9137-0PK13<br />

— u u — — 3VA9277-0PK13<br />

EMERGENCY-OFF Yellow-Red u — — — — 3VA9137-0PK15<br />

— u u — — 3VA9277-0PK15<br />

EMERGENCY-OFF<br />

with illumination kit<br />

Yellow-Red u — — — — 3VA9137-0PK17<br />

— u u — — 3VA9277-0PK17<br />

Standard with mounting plate Gray u — — — — 3VA9137-0PK51<br />

— u u — — 3VA9277-0PK51<br />

Standard with mounting plate, Gray u — — — — 3VA9137-0PK53<br />

with illumination kit<br />

— u u — — 3VA9277-0PK53<br />

EMERGENCY-OFF with<br />

Yellow-Red u — — — — 3VA9137-0PK55<br />

mounting plate<br />

— u u — — 3VA9277-0PK55<br />

EMERGENCY-OFF with mounting Yellow-Red u — — — — 3VA9137-0PK57<br />

plate, with illumination kit<br />

— u u — — 3VA9277-0PK57<br />

Standard for use with the side<br />

wall mounted rotary operators<br />

n Without mounting plate<br />

Gray u — — — — 3VA9177-0VF40<br />

— u u — — 3VA9277-0VF40<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-83


3VA Molded Case Circuit Breakers<br />

3VA Manual Operators<br />

Revised on 10/15/20<br />

Selection<br />

Breaker Operator<br />

Type<br />

Color<br />

3VA5<br />

125A<br />

3VA5<br />

250A<br />

3VA6<br />

150A<br />

250A<br />

3VA5<br />

3VA6<br />

400A<br />

600A<br />

3VA5<br />

3VA6<br />

800A<br />

1000A<br />

Catalog Number<br />

Without handle,<br />

without shaft adapter<br />

Gray u — — — — 3VA9137-0GK00<br />

— u u — — 3VA9277-0GK00<br />

— — — u — 3VA9447-0GK00<br />

Without handle,<br />

with shaft adapter<br />

Gray — — — — u 3VA9677-0GK00<br />

3VA9277-0GK00<br />

3VA9677-0GK00<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Handles with Masking Plate (Purchase breaker operator, shaft and shaft adapter separately)<br />

n Degree of protection<br />

Type 1, 12, 3R and 4X<br />

Type<br />

Color<br />

Tolerance<br />

Compensation<br />

Door<br />

Open<br />

Function<br />

3VA5<br />

125A<br />

3VA5<br />

250A<br />

3VA6<br />

150A<br />

250A<br />

3VA5<br />

3VA6<br />

400A<br />

600A<br />

3VA5<br />

3VA6<br />

800A<br />

1000A<br />

Catalog Number<br />

Standard Gray Without Without u u u — — 8UD1721-0AB11<br />

With Without u u u — — 8UD1721-0AB21<br />

Without Without — — — u — 8UD1731-0AB11<br />

With Without — — — u — 8UD1731-0AB21<br />

Without With u u u — — 8UD1721-0AC11<br />

With With u u u — — 8UD1721-0AC21<br />

Without With — — — u — 8UD1731-0AC11<br />

With With — — — u — 8UD1731-0AC21<br />

Without With — — — — u 8UD1741-0AB11<br />

With With — — — — u 8UD1741-0AB21<br />

Emergency<br />

Yellow-<br />

Red<br />

Without Without u u u — — 8UD1721-0AB15<br />

With Without u u u — — 8UD1721-0AB25<br />

Without Without — — — u — 8UD1731-0AB15<br />

With Without — — — u — 8UD1731-0AB25<br />

Without With u u u — — 8UD1721-0AC15<br />

With With u u u — — 8UD1721-0AC25<br />

Without With — — — u — 8UD1731-0AC15<br />

With With — — — u — 8UD1731-0AC25<br />

Without With — — — — u 8UD1741-0AB15<br />

With With — — — — u 8UD1741-0AB25<br />

Metal Rotary Handles (Purchase breaker operator, shaft and shaft adapter separately)<br />

n Large, degree of protection<br />

Type 1, 3, 3R, 12<br />

n Large, degree of protection<br />

Type 4, 4X<br />

Metal Black — With u u u u u RHOH<br />

Metal Stainless — With u u u u u RHOH4<br />

n Compact, degree of protection<br />

Type 1,3,3R,12<br />

Compact Black — With u u u u<br />

— RHOHC<br />

n Compact, degree of protection<br />

Type 4, 4X<br />

Compact Stainless — With u u u u<br />

—<br />

RHOH4C<br />

n Long, degree of protection<br />

1,3,3R,12<br />

n Compact, degree of protection<br />

1,3,3R,12<br />

Emergency Red — With u u u u u RHVPEMH<br />

Emergency Red — With u u u u — RHVMEMH<br />

For additional information for selecting handle and breaker operator combinations, please refer to the brochure:<br />

https://digitalcontentcenter.compas.siemens-info.com/SIE_FL_3VA_Handles.pdf<br />

7-84<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA Manual Operators<br />

Revised on 10/15/20<br />

Selection<br />

Pistol Grip Handles (Purchase breaker operator, shaft and shaft adapter separately)<br />

Type<br />

Color<br />

Tolerance<br />

Compensation<br />

Door<br />

Open<br />

Function<br />

3VA5<br />

125A<br />

3VA5<br />

250A<br />

3VA6<br />

150A<br />

250A<br />

3VA5<br />

3VA6<br />

400A<br />

600A<br />

3VA5<br />

3VA6<br />

800A<br />

1000A<br />

Catalog Number<br />

n Degree of protection<br />

Type 1,3R,12<br />

Plastic Gray — With u u u u — 3VA9477-0FH11<br />

n Degree of protection<br />

Type 1,3R,12<br />

Emergency Red — With u u u u — 3VA9477-0FH15<br />

Door Mounted Rotary Operator Accessories<br />

3VA5<br />

3VA6<br />

400A<br />

3VA5<br />

3VA6<br />

800A<br />

Type<br />

3VA5<br />

125A<br />

3VA5<br />

250A<br />

3VA6<br />

150A<br />

250A 600A 1000A Catalog Number<br />

8 mm Shaft 300 mm/12 in long for 8UD plastic handles u u u u — 8UD1900-2WA00<br />

(Fixing bracket optional)<br />

8 mm Shaft 600 mm/24 in long for 8UD plastic handles u u u u — 8UD1900-2WB00<br />

(Fixing bracket required)<br />

12 mm Shaft 300 mm/12 in long for 8UD plastic handles — — — — u 8UD1900-4WA00<br />

12 mm Shaft 600 mm/24 in long for 8UD plastic handles — — — — u 8UD1900-4WB00<br />

u u u u — 3VA9477-0GF20<br />

8 mm Shaft 300 mm/12 in long for metal handles<br />

(Fixing bracket optional)<br />

8 mm Shaft 600 mm/24 in long for metal handles<br />

(Fixing bracket required)<br />

12 mm Shaft 300/12 in mm long for metal handles<br />

(Fixing bracket optional)<br />

12 mm Shaft 600 mm/24 in long for metal handles<br />

(Fixing bracket required)<br />

8 mm Shaft 300/12 in mm long for pistol grip handles<br />

(Fixing bracket optional)<br />

8 mm Shaft 600 mm long/24 in for pistol grip handles<br />

(Fixing bracket required)<br />

u u u u — 3VA9477-0GF21<br />

— — — — u 3VA9877-0GF22<br />

— — — — u 3VA9877-0GF23<br />

u u u u — 3VA9477-0GF10<br />

u u u u — 3VA9477-0GF11<br />

Adapter for 8 mm Shaft for door mounted operator u u u u — 8UD1900-2DA00<br />

Adapter for 12 mm Shaft for door mounted operator — — — — u 8UD1900-4DA00<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Fixing bracket for Shaft u — — — — 3VA9137-0GA80<br />

— u u u — 3VA9477-0GA80<br />

Fixing bracket for 12 mm x 12 mm shaft — — — — u 3VA9677-0GA80<br />

Variable depth adapter 8 x 8 mm u u u u — 3VA9487-0GB10<br />

Door Coupling 8 mm x 8 mm<br />

(for 8UD plastic handles)<br />

Door coupling 12 mm x 12 mm<br />

(for 8UD plastic handles)<br />

Mounting tolerance compensation 8 x 8 mm<br />

(for 8UD plastic handles)<br />

Mounting tolerance compensation 12 mm x 12 mm<br />

(for 8UD plastic handles)<br />

u u u — — 8UD1900-2HA00<br />

— — — u u 8UD1900-4HA00<br />

u u u u — 8UD1900-2GA00<br />

— — — — u 8UD1900-4GA00<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-85


3VA Molded Case Circuit Breakers<br />

3VA Manual Operators<br />

Revised on 09/30/20<br />

Selection<br />

General Accessories for Manual Operators<br />

Type Details Part Number<br />

Labeling plate for<br />

— 3VA9087-0SX10<br />

manual operators<br />

Illumination kit for<br />

manual operators<br />

24 V DC voltage<br />

Cylinder Lock (type Kaba)<br />

n For 8UD plastic door mounted<br />

rotary operators (in masking plate)<br />

n Standard masking plate<br />

Cylinder Lock (type Kaba) a<br />

n For 8UD plastic door mounted<br />

rotary operators (in masking plate)<br />

n Standard masking plate<br />

Cylinder Lock (type Kaba)<br />

n For 8UD plastic door mounted<br />

rotary operators (in masking plate)<br />

n EMERGENCY-OFF masking plate<br />

Cylinder Lock (type Kaba) a<br />

n For 8UD plastic door mounted<br />

rotary operators (in masking plate)<br />

n EMERGENCY-OFF masking plate<br />

Cylinder Lock (type Ronis)<br />

n includes 2 keys<br />

n for locking or interlocking<br />

n installation in all rotary<br />

operators w/ shaft stub<br />

For Molded Case Circuit Breakers<br />

3VA5, 125...250 A Front mounted rotary<br />

operators<br />

3VA6, 150...600 A<br />

3VA5, 3VA6,<br />

125...600 A<br />

3VA5, 3VA6,<br />

800..1000A<br />

Key 1<br />

Key 2<br />

Key 3<br />

Key 4<br />

Key 1<br />

Key 2<br />

Key 3<br />

Key 4<br />

Key 1<br />

Key 2<br />

Key 3<br />

Key 4<br />

Key 1<br />

Key 2<br />

Key 3<br />

Key 4<br />

Key 1<br />

Key 3<br />

Key 4<br />

Door mounted rotary<br />

operators<br />

8UD1900-0KA10<br />

8UD1900-0KA20<br />

8UD1900-0KA20<br />

8UD1900-0KA30<br />

8UD1900-0MB01<br />

8UD1900-0NB01<br />

8UD1900-0PB01<br />

8UD1900-0QB01<br />

8UD1900-0MC01<br />

8UD1900-0NC01<br />

8UD1900-0PC01<br />

8UD1900-0QC01<br />

8UD1900-0MB05<br />

8UD1900-0NB05<br />

8UD1900-0PB05<br />

8UD1900-0QB05<br />

8UD1900-0MC05<br />

8UD1900-0NC05<br />

8UD1900-0PC05<br />

8UD1900-0QC05<br />

3VA9980-0VL10<br />

3VA9980-0VL30<br />

3VA9980-0VL40<br />

7<br />

Cylinder lock adapter for 8UD rotary operator<br />

n to mount in rotary operator<br />

3VA9980-0LF20<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Variable depth flange mounted operator kit<br />

Cylinder lock adaptor for front mounted rotary operator<br />

3VA9677-0EK.. and door mounted rotary operator 3VA9677-0FK..<br />

3VA55/3VA65/3VA66<br />

Type<br />

Complete kit comprising:<br />

n Switching mechanism adjustable depth<br />

200mm to 400mm<br />

n Epoxy coated steel handle, NEMA 1/3R/12,<br />

black = OFF, red = ON<br />

Complete kit comprising:<br />

n Switching mechanism adjustable depth<br />

200mm to 400mm<br />

n Stainless steel handle, chrome-plated NEMA 4/4X,<br />

black=OFF, red=ON<br />

Complete kit comprising:<br />

n Swithching mechanism adjustable depth<br />

200mm to 400mm<br />

n Handle stainless steel, chrome-plated NEMA 4/4X,<br />

black=OFF, black=ON<br />

3VA5<br />

125A<br />

3VA6<br />

150A<br />

250A<br />

3VA5<br />

3VA6<br />

400A<br />

600A<br />

3VA9670-0LF20<br />

3VA5<br />

250A<br />

Catalog Number<br />

u — — — 3VA9138-0DK72<br />

— u u — 3VA9278-0DK72<br />

— — — u 3VA9478-0DK72<br />

u — — — 3VA9138-0DK82<br />

— u u — 3VA9278-0DK82<br />

— — — u 3VA9478-0DK82<br />

u — — — 3VA9138-0DK84<br />

— u u — 3VA9278-0DK84<br />

— — — u 3VA9478-0DK84<br />

a With door open function<br />

7-86<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA Manual and Motor Operators<br />

Revised on 09/30/20<br />

Selection<br />

Max Flex Operator<br />

Type<br />

Complete Kit<br />

n Operating mechanism<br />

n Plastic handle, NEMA 1/12, black=OFF, green=ON<br />

n Bowden Cable 36 inches (0.9m) long<br />

Complete Kit<br />

n Operating mechanism<br />

n Steel handle, epoxy coated NEMA 1/3R/12,<br />

black=OFF, red=ON,<br />

n Bowden Cable 36 inches (0.9m) long<br />

3VA5<br />

125A<br />

3VA6<br />

150A<br />

250A<br />

3VA5<br />

3VA6<br />

400A<br />

600A<br />

3VA5<br />

250A<br />

Catalog Number<br />

u — — — 3VA9137-0CK12<br />

— u u — 3VA9277-0CK12<br />

— — — u 3VA9477-0CK12<br />

u — — — 3VA9137-0CK72<br />

— u u — 3VA9277-0CK72<br />

— — — u 3VA9477-0CK72<br />

Complete kit and spare mechanism<br />

Motor Operators a<br />

a Lockable with up to three padlock hasps.<br />

Type<br />

Operating Mechanism (spare) u — — — 3VA9137-0CB10<br />

— u u — 3VA9277-0CB10<br />

— — — u 3VA9477-0CB10<br />

Handle - Plastic, NEMA 1/12,<br />

u u u u 3VA9977-0CH12<br />

black = OFF, green = ON<br />

Handle - Steel, Epoxy coated, NEMA 1/3R/12,<br />

u u u u 3VA9977-0CH72<br />

black = OFF, red = ON<br />

Handle - Steel, Epoxy coated, NEMA 1/3R/12,<br />

u u u u 3VA9977-0CH74<br />

black = OFF, black = ON<br />

Handle - Steel, chrome-plated, NEMA 4/4X,<br />

u u u u 3VA9977-0CH82<br />

black = OFF, red = ON<br />

Handle - Steel, chrome-plated, NEMA 4/4X,<br />

u u u u 3VA9977-0CH84<br />

black = OFF, black = ON<br />

Bowden Cable, 36 inches (0.9m) u u u — 3VA9278-0CC10<br />

Bowden Cable, 48 inches (1.2m) u u u — 3VA9278-0CC20<br />

Bowden Cable, 60 inches (1.5m) u u u — 3VA9278-0CC30<br />

Bowden Cable, 72 inches (1.8m) u u u — 3VA9278-0CC40<br />

Bowden Cable, 84 inches (2.1m) u u u — 3VA9278-0CC50<br />

Bowden Cable, 96 inches (2.4m) u u u — 3VA9278-0CC60<br />

Bowden Cable, 120 inches (3.0m) u u u — 3VA9278-0CC70<br />

Bowden Cable, 144 inches (3.6m) u u u — 3VA9278-0CC80<br />

Bowden Cable, 36 inches (0.9m) — — — u 3VA9578-0CC10<br />

Bowden Cable, 48 inches (1.2m) — — — u 3VA9578-0CC20<br />

Bowden Cable, 60 inches (1.5m) — — — u 3VA9578-0CC30<br />

Bowden Cable, 72 inches (1.8m) — — — u 3VA9578-0CC40<br />

Bowden Cable, 84 inches (2.1m) — — — u 3VA9578-0CC50<br />

Bowden Cable, 96 inches (2.4m) — — — u 3VA9578-0CC60<br />

Bowden Cable, 120 inches (3.0m) — — — u 3VA9578-0CC70<br />

Bowden Cable, 144 inches (3.6m) — — — u 3VA9578-0CC80<br />

MaxFlex Auxiliary switch (leading from On to Off)<br />

n 1 CO<br />

u u u u 3VA9478-0CX10<br />

MaxFlex Auxiliary switch (leading from On to Off)<br />

n 2 CO<br />

u u u u 3VA9478-0CX20<br />

3VA5<br />

125 A<br />

3VA5<br />

250 A<br />

3VA6<br />

150 A<br />

250 A<br />

3VA5<br />

3VA6<br />

400A<br />

600A<br />

Part Number<br />

Motor Operator without Stored Energy Feature<br />

24 ... 60 V DC u — — — 3VA9137-0HA10<br />

— u u — 3VA9277-0HA10<br />

— — — u 3VA9447-0HA10<br />

110 ... 230 V AC<br />

u — — — 3VA9137-0HA20<br />

110 ... 250 V DC<br />

— u u — 3VA9277-0HA20<br />

— — — u 3VA9447-0HA20<br />

Motor Operator with Stored Energy Feature<br />

24 V DC — u u — 3VA9277-0HC10<br />

42 ... 60 V AC/DC — u u — 3VA9277-0HC20<br />

110 ... 230 V AC / 110 ... 250 V DC — u u — 3VA9277-0HC30<br />

Motor Operator with Stored Energy Feature with Communication<br />

24 V DC — u u — 3VA9277-0HC15<br />

110 ... 230 V AC / 110 ... 250 V DC — u u — 3VA9277-0HC35<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-87


3VA Molded Case Circuit Breakers<br />

3VA Connection Technology<br />

Revised on 10/15/20<br />

Selection<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Box Terminals<br />

Type<br />

Steel wrap-around lug<br />

(Cu cable only)<br />

kit of 3 single lugs<br />

Steel wrap-around lug<br />

(Cu cable only)<br />

kit of 4 single lugs<br />

Steel wrap-around lug<br />

with control wire tap<br />

(Cu cable only)<br />

kit of 3 single lugs<br />

Steel wrap-around lug<br />

with control wire tap<br />

(Cu cable only)<br />

kit of 4 single lugs<br />

Aluminum Wire Connectors<br />

Aluminum body lug<br />

small (Cu/Al cable)<br />

kit of 3 single lugs<br />

Aluminum body lug<br />

small (Cu/Al cable)<br />

kit of 4 single lugs<br />

Aluminum body lug<br />

small with control wire<br />

tap (Cu/Al cable)<br />

Aluminum body lug<br />

small with control wire<br />

tap (Cu/Al cable)<br />

Aluminum body lug<br />

(Cu/Al cable)<br />

kit of 3 single lugs<br />

Aluminum body lug<br />

(Cu/Al cable)<br />

kit of 4 single lugs<br />

Aluminum body lug<br />

with control wire tap<br />

(Cu/Al cable)<br />

kit of 3 single lugs<br />

Aluminum body lug with<br />

control wire tap (Cu/Al<br />

cable) kit of 4 single lugs<br />

Aluminum body lug<br />

two cables (Cu/Al cable)<br />

kit of 3 single lugs<br />

Minimum<br />

cable crosssection<br />

(standard)<br />

Class B<br />

Maximum<br />

cable crosssection<br />

(standard)<br />

Class B<br />

For molded case circuit breakers/<br />

rated current<br />

3VA5<br />

125A<br />

3VA5<br />

250A<br />

3VA6<br />

150A<br />

250A<br />

3VA5<br />

3VA6<br />

400A<br />

600A<br />

3VA5<br />

3VA6<br />

800A<br />

1000A<br />

Part Number<br />

AWG 14 3/0 u — — — — 3VA9133-0JA11<br />

AWG 10 3/0 — u — — — 3VA9233-0JA11<br />

AWG 4 350 kcmil — u — — — 3VA9233-0JA12<br />

AWG 10 3/0 — — u — — 3VA9143-0JA12<br />

AWG 4 350 kcmil — — u — — 3VA9243-0JA12<br />

1/0 500 kcmil — — — u — 3VA9473-0JA13<br />

AWG 14 3/0 u — — — — 3VA9134-0JA11<br />

AWG 10 3/0 — u — — — 3VA9234-0JA11<br />

AWG 4 350 kcmil — u — — — 3VA9234-0JA12<br />

AWG 10 3/0 — — u — — 3VA9144-0JA12<br />

AWG 4 350 kcmil — — u — — 3VA9244-0JA12<br />

1/0 500 kcmil — — — u — 3VA9474-0JA13<br />

AWG 10 3/0 — u — — — 3VA9233-0JH11<br />

AWG 4 350 kcmil — u — — — 3VA9233-0JH12<br />

AWG 10 3/0 — — u — — 3VA9143-0JH12<br />

AWG 4 350 kcmil — — u — — 3VA9243-0JH12<br />

1/0 500 kcmil — — — u — 3VA9473-0JH13<br />

AWG 10 3/0 — u — — — 3VA9234-0JH11<br />

AWG 4 350 kcmil — u — — — 3VA9234-0JH12<br />

AWG 10 3/0 — — u — — 3VA9144-0JH12<br />

AWG 4 350 kcmil — — u — — 3VA9244-0JH12<br />

1/0 500 kcmil — — — u — 3VA9474-0JH13<br />

AWG 14 AWG 10 u — — — — 3VA9133-0JB10<br />

AWG 14 AWG 10 u — — — — 3VA9134-0JB10<br />

AWG 14 AWG 10 u — — — — 3VA9133-0JG10<br />

AWG 14 AWG 10 u — — — — 3VA9134-0JG10<br />

AWG 8 3/0 u — — — — 3VA9133-0JB11<br />

AWG 14 1/0 — u — — — 3VA9233-0JB11<br />

AWG 6 350 kcmil — u — — — 3VA9233-0JB12 b<br />

AWG 14 1/0 — — u — — 3VA9143-0JB11 b<br />

AWG 6 350 kcmil — — u — — 3VA9243-0JB12<br />

2/0 600 kcmil — — — u — 3VA9373-0JB13 a<br />

AWG 8 3/0 u — — — — 3VA9134-0JB11<br />

AWG 14 1/0 — u — — — 3VA9234-0JB11<br />

AWG 6 350 kcmil — u — — — 3VA9234-0JB12<br />

AWG 14 1/0 — — u — — 3VA9144-0JB11 b<br />

AWG 6 350 kcmil — — u — — 3VA9244-0JB12 b<br />

2/0 600 kcmil — — — u — 3VA9374-0JB13 a<br />

AWG 8 3/0 u — — — — 3VA9133-0JG11<br />

AWG 14 1/0 — u — — — 3VA9233-0JG11<br />

AWG 6 350 kcmil — u — — — 3VA9233-0JG12<br />

AWG 14 1/0 — — u — — 3VA9143-0JG11 b<br />

AWG 6 350 kcmill — — u — — 3VA9243-0JG12 b<br />

2/0 600 kcmil — — — u — 3VA9373-0JG13 a<br />

AWG 8 3/0 u — — — — 3VA9134-0JG11<br />

AWG 14 1/0 — u — — — 3VA9234-0JG11<br />

AWG 6 350 kcmil — u — — — 3VA9234-0JG12<br />

AWG 14 1/0 — — u — — 3VA9144-0JG11 b<br />

AWG 6 350 kcmil — — u — — 3VA9244-0JG12 b<br />

2/0 600 kcmil — — — u — 3VA9374-0JG13 a<br />

4/0 600 kcmil — — — — u 3VA9573-0JB23<br />

aThis conductor is ampere-rated at 380A with copper wire and 310A with aluminum wire. bMeets requirements of 100% rated breakers up to 150A.<br />

7-88<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA Connection Technology<br />

Revised on 10/15/20<br />

Selection<br />

Aluminum Wire Connectors (cont.)<br />

3 lug kit<br />

pictured<br />

4 lug kit<br />

pictured<br />

Type<br />

Aluminum body lug<br />

two cables (Cu/Al cable)<br />

kit of 4 single lugs<br />

Aluminum body lug<br />

two cables with control<br />

wire tap (Cu/Al cable)<br />

kit of 3 single lugs<br />

Aluminum body lug<br />

two cables with control<br />

wire tap (Cu/Al cable)<br />

kit of 4 single lugs<br />

Aluminum body lug<br />

three cables (Cu/Al cable)<br />

kit of 3 single lugs<br />

Aluminum body lug<br />

three cables (Cu/Al cable)<br />

kit of 4 single lugs<br />

Aluminum body lug<br />

three cables with control<br />

wire tap (Cu/Al cable)<br />

kit of 3 single lugs<br />

Aluminum body lug<br />

three cables with control<br />

wire tap (Cu/Al cable)<br />

kit of 4 single lugs<br />

Minimum<br />

cable crosssection<br />

(standard)<br />

Class B<br />

Aluminum Wire Connectors and Terminal Covers<br />

Type<br />

Aluminum body lug large<br />

(Cu/Al cable)<br />

2 lug 3 lug 4 lug<br />

Aluminum body lug large with<br />

control wire tap (Cu/Al cable)<br />

Description<br />

Kit of 2 single lugs and<br />

1 extended terminal cover<br />

Kit of 3 single lugs and<br />

1 extended terminal cover<br />

Kit of 4 single lugs and<br />

1 extended terminal cover<br />

Kit of 2 single lugs and<br />

1 extended terminal cover<br />

Kit of 3 single lugs and<br />

1 extended terminal cover<br />

Maximum<br />

cable crosssection<br />

(standard)<br />

Class B<br />

For molded case circuit breakers/<br />

rated current<br />

3VA6<br />

150A<br />

250A<br />

3VA5<br />

3VA6<br />

400A<br />

600A<br />

3VA5<br />

3VA6<br />

800A<br />

1000A<br />

3VA5 3VA5<br />

125A 250A<br />

Part Number<br />

4/0 600 kcmil — — — — u 3VA9574-0JB23<br />

4/0 600 kcmil — — — — u 3VA9673-0JG23<br />

4/0 600 kcmil — — — — u 3VA9674-0JG23<br />

4/0 400 kcmil — — — — u 3VA9673-0JB32<br />

4/0 400 kcmil — — — — u 3VA9674-0JB32<br />

4/0 400 kcmil — — — — u 3VA9673-0JG32<br />

4/0 400 kcmil — — — — u 3VA9674-0JG32<br />

Min.<br />

cable<br />

crosssection<br />

(std.)<br />

Class B<br />

Max.<br />

cable<br />

crosssection<br />

(std.)<br />

Class B<br />

For molded case circuit breakers/<br />

rated current<br />

3VA6<br />

150A<br />

250A<br />

3VA5<br />

3VA6<br />

400A<br />

600A<br />

3VA5<br />

3VA6<br />

800A<br />

1000A<br />

3VA5 3VA5<br />

125A 250A<br />

Part Number<br />

AWG 4 300 kcmil u — — — — 3VA9132-0JJ12<br />

AWG 4 300 kcmil u — — — — 3VA9133-0JJ12<br />

AWG 2 350 kcmil — u — — — 3VA9233-0JJ13<br />

AWG 2 350 kcmil — — u — — 3VA9243-0JJ13 a<br />

AWG 4 300 kcmil u — — — — 3VA9134-0JJ12<br />

AWG 2 350 kcmil — u — — — 3VA9234-0JJ13<br />

AWG 2 350 kcmil — — u — — 3VA9244-0JJ13 a<br />

AWG 4 300 kcmil u — — — — 3VA9132-0JC12<br />

Terminal Cover<br />

with Probe<br />

Holes Part<br />

Number<br />

AWG 4 300 kcmil u — — — — 3VA9133-0JC12 3VA9133-0JC18<br />

AWG 2 350 kcmil — u — — — 3VA9233-0JC13 3VA9233-0JC18<br />

AWG 2 350 kcmil — — u — — 3VA9243-0JC13 a 3VA9243-0JC18<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

2 lug 3 lug 4 lug<br />

Aluminum body lug,<br />

2 Cables (Cu/Al cable)<br />

Kit of 4 single lugs and<br />

1 extended terminal cover<br />

Kit of 3 single lugs and<br />

1 extended terminal cover<br />

AWG 4 300 kcmil u — — — — 3VA9134-0JC12<br />

AWG 2 350 kcmil — u — — — 3VA9234-0JC13<br />

AWG 2 350 kcmil — — u — — 3VA9244-0JC13 a<br />

AWG 4 300 kcmil — u — — — 3VA9233-0JJ22<br />

AWG 4 300 kcmil — — u — — 3VA9243-0JJ22 a<br />

2/0 600 kcmil — — — u — 3VA9473-0JJ23<br />

3 lug 4 lug<br />

Kit of 4 single lugs and<br />

1 extended terminal cover<br />

AWG 4 300 kcmil — u — — — 3VA9234-0JJ22<br />

AWG 4 300 kcmil — — u — — 3VA9244-0JJ22 a<br />

2/0 600 kcmil — — — u — 3VA9474-0JJ23<br />

a Meets requirements of 100% rated breakers up to 250A.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-89


3VA Molded Case Circuit Breakers<br />

3VA Connection Technology<br />

Revised on 08/31/20<br />

Selection<br />

Aluminum Wire Connectors and Terminal Covers (cont.)<br />

Type<br />

Description<br />

Aluminum body lug, 2 Cables Kit of 3 single lugs and<br />

with control wire tap (Cu/Al cable) 1 extended terminal cover<br />

Min.<br />

cable<br />

crosssection<br />

(std.)<br />

Class B<br />

Max.<br />

cable<br />

crosssection<br />

(std.)<br />

Class B<br />

For molded case circuit breakers/<br />

rated current<br />

3VA5 3VA5<br />

Terminal Cover<br />

3VA6 3VA6 3VA6<br />

with Probe<br />

3VA5 3VA5 150A 400A 800A<br />

Holes Part<br />

125A 250A 250A 600A 1000A Part Number Number<br />

AWG 4 300 kcmil — u — — 3VA9233-0JC22 3VA9233-0JC28<br />

AWG 4 300 kcmil — — u — 3VA9243-0JC22 a 3VA9243-0JC28<br />

2/0 600 kcmil — — — u 3VA9473-0JC23 3VA9473-0JC28<br />

Kit of 4 single lugs and<br />

1 extended terminal cover<br />

AWG 4 300 kcmil — u — — 3VA9234-0JC22<br />

AWG 4 300 kcmil — — u — 3VA9244-0JC22 a<br />

2/0 600 kcmil — — — u 3VA9474-0JC23<br />

3 lug 4 lug<br />

Aluminum body<br />

lug two cables<br />

(Cu/Al cable)<br />

3 lug kit pictured<br />

Kit of 3 single lugs and<br />

1 extended terminal cover<br />

Kit of 4 single lugs and<br />

1 extended terminal cover<br />

400 kcmil 750 kcmil — — — — u 3VA9673-0JJ24<br />

400 kcmil 750 kcmil — — — — u 3VA9674-0JJ24<br />

Aluminum body<br />

lug two cables with<br />

control wire tap<br />

(Cu/Al cable)<br />

3 kit lug pictured<br />

Kit of 3 single lugs and<br />

1 extended terminal cover<br />

Kit of 4 single lugs and<br />

1 extended terminal cover<br />

400 kcmil 750 kcmil — — — — u 3VA9673-0JC24<br />

400 kcmil 750 kcmil — — — — u 3VA9674-0JC24<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Aluminum body lug<br />

three cables (Cu/Al cable)<br />

Aluminum body lug three cables<br />

with control wire tap (Cu/Al cable)<br />

Aluminum body<br />

lug four cables<br />

(Cu/Al cable)<br />

4 lug kit pictured<br />

Aluminum body<br />

lug four cables<br />

with control wire<br />

tap (Cu/Al cable)<br />

4 lug kit pictured<br />

Kit of 3 single lugs and<br />

1 extended terminal cover<br />

Kit of 4 single lugs and<br />

1 extended terminal cover<br />

Kit of 3 single lugs and<br />

1 extended terminal cover<br />

Kit of 4 single lugs and<br />

1 extended terminal cover<br />

Kit of 3 single lugs and<br />

1 extended terminal cover<br />

Kit of 4 single lugs and<br />

1 extended terminal cover<br />

Kit of 3 single lugs and<br />

1 extended terminal cover<br />

Kit of 4 single lugs and<br />

1 extended terminal cover<br />

500 kcmil 750 kcmil — — — — u 3VA9673-0JJ34<br />

500 kcmil 750 kcmil — — — — u 3VA9674-0JJ34<br />

500 kcmil 750 kcmil — — — — u 3VA9673-0JC34<br />

500 kcmil 750 kcmil — — — — u 3VA9674-0JC34<br />

4/0 500 kcmil — — — — u 3VA9673-0JJ43<br />

4/0 500 kcmil — — — — u 3VA9674-0JJ43<br />

4/0 500 kcmil — — — — u 3VA9673-0JC43<br />

4/0 500 kcmil — — — — u 3VA9674-0JC43<br />

Aluminum body lug<br />

four cables (Cu/Al cable)<br />

Aluminum body lug four cables<br />

with control wire tap (Cu/Al cable)<br />

Distribution lug,<br />

6 Cables (Cu/Al cable)<br />

2 lug 3 lug 4 lug<br />

Kit of 3 single lugs and<br />

1 extended terminal cover<br />

Kit of 4 single lugs and<br />

1 extended terminal cover<br />

Kit of 3 single lugs and<br />

1 extended terminal cover<br />

Kit of 4 single lugs and<br />

1 extended terminal cover<br />

Kit of 2 single lugs and<br />

1 extended terminal cover<br />

Kit of 3 single lugs and<br />

1 extended terminal cover<br />

Kit of 4 single lugs and<br />

1 extended terminal cover<br />

4/0 600 kcmil — — — — u 3VA9673-0JJ44<br />

4/0 600 kcmil — — — — u 3VA9674-0JJ44<br />

4/0 600 kcmil — — — — u 3VA9673-0JC44<br />

4/0 600 kcmil — — — — u 3VA9674-0JC44<br />

AWG 14 AWG 2 u — — — 3VA9132-0JF60<br />

AWG 14 AWG 2 u — — — 3VA9133-0JF60 3VA9133-0JF68<br />

AWG 2 — u — — 3VA9233-0JF60 3VA9233-0JF68<br />

AWG 2 — — u — 3VA9243-0JF60 b 3VA9243-0JF68<br />

AWG 2 — — — u 3VA9373-0JF60 c 3VA9373-0JF68<br />

AWG 14 AWG 2 u — — — 3VA9134-0JF60<br />

AWG 2 — u — — 3VA9234-0JF60<br />

AWG 2 — — u — 3VA9244-0JF60 b<br />

AWG 2 — — — u 3VA9374-0JF60 c<br />

a Meets requirements of 100% rated breakers up to 250A.<br />

b Meets requirements of 100% rated breakers up to 100A. c Meets requirements of 100% rated breakers up to 100A.<br />

7-90<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA Connection Technology<br />

Revised on 10/15/20<br />

Selection<br />

Copper Wire Connectors<br />

Type<br />

Copper body lug, small (Cu cable<br />

only) Kit of 3 single lugs<br />

Minimum<br />

cable crosssection<br />

(standard)<br />

Class B<br />

Maximum<br />

cable crosssection<br />

(standard)<br />

Class B<br />

For molded case circuit breakers/<br />

rated current<br />

3VA6<br />

150A<br />

250A<br />

3VA5<br />

3VA6<br />

400A<br />

600A<br />

3VA5<br />

3VA6<br />

800A<br />

1000A<br />

3VA5 3VA5<br />

125A 250A<br />

Part Number<br />

AWG 14 AWG 10 u — — — — 3VA9133-0JD10<br />

Copper body lug (Cu cable only)<br />

Kit of 3 single lugs<br />

Copper body lug, small (Cu cable<br />

only) Kit of 4 single lugs<br />

AWG 14 2/0 u — — — — 3VA9133-0JD11<br />

AWG 14 1/0 — u — — — 3VA9233-0JD11<br />

AWG 6 350 kcmil — u — — — 3VA9233-0JD12<br />

AWG 14 1/0 — — u — — 3VA9143-0JD11<br />

AWG 6 350 kcmil — — u — — 3VA9243-0JD12<br />

2/0 600 kcmil — — — u — 3VA9373-0JD13<br />

AWG 14 AWG 10 u — — — 3VA9134-0JD10<br />

Copper body lug (Cu cable only)<br />

kit of 4 single lugs<br />

Copper body lug, three cables (Cu<br />

cable) Kit of 3 single lugs<br />

Copper body lug, three cables (Cu<br />

cable) Kit of 4 single lugs<br />

Copper body lug, small with control<br />

wire tap (Cu cable only)<br />

Kit of 3 single lugs<br />

AWG 14 AWG 10 u — — — — 3VA9134-0JD11<br />

AWG 14 1/0 — u — — — 3VA9234-0JD11<br />

AWG 6 350 kcmil — u — — — 3VA9234-0JD12<br />

AWG 14 1/0 — — u — — 3VA9144-0JD11<br />

AWG 6 350 kcmil — — u — — 3VA9244-0JD12<br />

2/0 600 kcmil — — — u — 3VA9374-0JD13<br />

4/0 400 kcmil — — — — u 3VA9673-0JD32<br />

4/0 400 kcmil — — — — u 3VA9674-0JD32<br />

AWG 14 AWG 10 u — — — 3VA9133-0JK10<br />

Copper body lug with control wire<br />

tap (Cu cable only)<br />

Kit of 3 single lugs<br />

Copper body lug, small with<br />

control wire tap (Cu cable only)<br />

Kit of 4 single lugs<br />

Copper body lug with control wire<br />

tap (Cu cable only)<br />

Kit of 4 single lugs<br />

Copper body lug, three cables<br />

with control wire tap (Cu cable)<br />

Kit of 3 single lugs<br />

Copper body lug, three cables<br />

with control wire tap (Cu cable)<br />

Kit of 4 single lugs<br />

AWG 14 2/0 u — — — — 3VA9133-0JK11<br />

AWG 14 1/0 — u — — — 3VA9233-0JK11<br />

AWG 6 350 kcmil — u — — — 3VA9233-0JK12<br />

AWG 14 1/0 — — u — — 3VA9143-0JK11<br />

AWG 6 350 kcmil — — u — — 3VA9243-0JK12<br />

2/0 600 kcmil — — — u — 3VA9373-0JK13<br />

AWG 14 2/0 u — — — 3VA9134-0JK10<br />

AWG 14 AWG 10 u — — — — 3VA9134-0JK11<br />

AWG 14 1/0 — u — — — 3VA9234-0JK11<br />

AWG 6 350 kcmil — u — — — 3VA9234-0JK12<br />

AWG 14 1/0 — — u — — 3VA9144-0JK11<br />

AWG 6 350 kcmil — — u — — 3VA9244-0JK12<br />

2/0 600 kcmil — — — u — 3VA9374-0JK13<br />

400 kcmil 600 kcmil — — — — u 3VA9673-0JK32<br />

400 kcmil 600 kcmil — — — — u 3VA9674-0JK32<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-91


3VA Molded Case Circuit Breakers<br />

3VA Connection Technology<br />

Revised on 08/31/20<br />

Selection<br />

Copper Wire Connectors (cont.)<br />

Type<br />

Copper body lug, 2 Cables (Cu<br />

cable only) Kit of 3 single lugs<br />

and 1 extended terminal cover<br />

Minimum<br />

cable crosssection<br />

(standard)<br />

Class B<br />

Maximum<br />

cable crosssection<br />

(standard)<br />

Class B<br />

For molded case circuit breakers/<br />

rated current<br />

3VA6<br />

150A<br />

250A<br />

3VA5<br />

3VA6<br />

400A<br />

600A<br />

3VA5<br />

3VA6<br />

800A<br />

1000A<br />

3VA5 3VA5<br />

125A 250A<br />

Part Number<br />

2/0 600 kcmil — — — u — 3VA9473-0JE23<br />

Copper body lug 2 Cables (Cu<br />

cable only) Kit of 4 single lugs<br />

and 1 extended terminal cover<br />

2/0 600 kcmil — — — u — 3VA9474-0JE23<br />

Copper body lug, four cables<br />

(Cu cable) Kit of 3 single lugs and<br />

1 extended terminal cover<br />

4/0 500 kcmil — — — — u 3VA9673-0JE43<br />

Copper body lug, four cables<br />

(Cu cable) Kit of 4 single lugs and<br />

1 extended terminal cover<br />

4/0 500 kcmil — — — — u 3VA9674-0JE43<br />

Copper body lug, four cables<br />

(Cu cable) Kit of 3 single lugs and<br />

1 extended terminal cover<br />

4/0 500 kcmil — — — — u 3VA9673-0JL43<br />

Copper body lug, four cables<br />

(Cu cable) Kit of 4 single lugs and<br />

1 extended terminal cover<br />

4/0 500 kcmil — — — — u 3VA9674-0JL43<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Nut Keeper Kits<br />

4 lug kit pictured<br />

Type<br />

Nut keeper kit<br />

kit of 3 single lugs<br />

Nut keeper kit<br />

kit of 4 single lugs<br />

Nut keeper kit<br />

kit of 3 single lug<br />

and terminal<br />

covers<br />

Nut keeper kit<br />

kit of 4 single lug<br />

and terminal<br />

covers<br />

Maximum<br />

terminal<br />

width<br />

Maximum<br />

terminal<br />

thickness<br />

For molded case circuit breakers/<br />

rated current<br />

3VA5<br />

125A<br />

3VA5<br />

250A<br />

3VA6<br />

150A<br />

250A<br />

3VA5<br />

3VA6<br />

400A<br />

600A<br />

3VA5<br />

3VA6<br />

800A<br />

1000A<br />

Part Number<br />

17 mm / 0.7 inch 6.5 mm /0.25 inch u — — — — 3VA9133-0QA00<br />

25 mm / 1 inch 8 mm / 0.3 inch — u — — — 3VA9233-0QA00<br />

25 mm / 1 inch 8 mm / 0.3 inch — — u — — 3VA9243-0QA00<br />

35 mm / 1.4 inch 10 mm / 0.4 inch — — — u — 3VA9473-0QA00<br />

17 mm / 0.7 inch 6.5 mm /0.25 inch u — — — — 3VA9134-0QA00<br />

25 mm / 1 inch 8 mm / 0.3 inch — u — — — 3VA9234-0QA00<br />

25 mm / 1 inch 8 mm / 0.3 inch — — u — — 3VA9244-0QA00<br />

35 mm / 1.4 inch 10 mm / 0.4 inch — — — u — 3VA9474-0QA00<br />

50 mm / 2.0 inch 30 mm / 1.18 inch — — — — u 3VA9673-0QA00<br />

50 mm / 2.0 inch 30 mm / 1.18 inch — — — — u 3VA9674-0QA00<br />

7-92<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA Connection Technology<br />

Revised on 08/31/20<br />

Selection<br />

Bus Connector Extensions<br />

Type<br />

Front bus connectors<br />

extended 1 single connector<br />

Maximum<br />

terminal<br />

width<br />

22 mm /<br />

0.9 inch<br />

Maximum<br />

terminal<br />

thickness<br />

8 mm /<br />

0.3 inch<br />

For molded case circuit breakers/<br />

rated current<br />

3VA5<br />

3VA6<br />

400A<br />

3VA5<br />

3VA6<br />

800A<br />

3VA5<br />

125A<br />

3VA5<br />

250A<br />

3VA6<br />

150A<br />

250A 600A 1000A Part Number<br />

u — — — — 3VA9131-0QB00<br />

Front bus connectors<br />

extended kit of 3 single connectors,<br />

2 phase barriers, and 1 insulating<br />

plate<br />

22 mm /<br />

0.9 inch<br />

8 mm /<br />

0.3 inch<br />

u — — — — 3VA9133-0QB00<br />

Front bus connectors<br />

extended kit of 4 single connectors,<br />

3 phase barriers, and 1 insulating<br />

plate<br />

22 mm /<br />

0.9 inch<br />

8 mm /<br />

0.3 inch<br />

u — — — — 3VA9133-0QB00<br />

Front bus connectors<br />

extended kit of 3 single connectors<br />

and 1 insulating plate<br />

32 mm /<br />

1.3 inch<br />

40 mm /<br />

1.6 inch<br />

10 mm /<br />

0.4 inch<br />

12.5 mm /<br />

0.5 inch<br />

— u u — — 3VA9273-0QB00<br />

— — — u — 3VA9473-0QB00<br />

Front bus connectors<br />

extended kit of 4 single connectors<br />

and 1 insulating plate<br />

50.8 mm /<br />

2.0 inch<br />

32 mm /<br />

1.3 inch<br />

40 mm /<br />

1.6 inch<br />

30 mm /<br />

1.18 inch<br />

10 mm /<br />

0.4 inch<br />

12.5 mm /<br />

0.5 inch<br />

— — — — u 3VA9673-0QB00<br />

— — u — — 3VA9274-0QB00<br />

— — — u — 3VA9474-0QB00<br />

50.8 mm /<br />

2.0 inch<br />

30 mm /<br />

1.18 inch<br />

— — — — u 3VA9674-0QB00<br />

Front bus connectors<br />

offset kit of 3 single connectors<br />

1 insulating plate<br />

Distance between pole centers:<br />

400/600 A = 70 mm / 2.76 inches<br />

Front bus connectors<br />

offset kit of 4 single connectors<br />

1 insulating plate<br />

Distance between pole centers:<br />

400/600 A = 70 mm / 2.76 inches<br />

60 mm /<br />

2.4 inch<br />

80 mm /<br />

3.15 inch<br />

60 mm /<br />

2.4 inch<br />

80 mm /<br />

3.15 inch<br />

12.5 mm /<br />

0.5 inch<br />

30 mm /<br />

1.18 inch<br />

12.5 mm /<br />

0.5 inch<br />

30 mm /<br />

1.18 inch<br />

— — — u — 3VA9473-0QC00<br />

— — — — u 3VA9673-0QC00<br />

— — — u — 3VA9474-0QC00<br />

— — — — u 3VA9674-0QC00<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-93


3VA Molded Case Circuit Breakers<br />

3VA Connection Technology<br />

Rear connection studs flat<br />

Rear connection studs round<br />

Type<br />

Rear connection studs flat<br />

kit of 2 short flat studs and<br />

1 long flat stud<br />

Rear connection studs flat<br />

kit of 2 short flat studs and<br />

2 long flat studs<br />

Rear connection studs flat<br />

1 short flat stud<br />

Rear connection studs flat<br />

1 long flat stud<br />

Rear connection studs round<br />

kit of 1 long round stud and<br />

2 short round studs<br />

For molded case circuit breakers/<br />

rated current<br />

3VA5<br />

125A<br />

3VA6<br />

150A<br />

250A<br />

3VA5<br />

3VA6<br />

400A<br />

600A<br />

Revised on 08/31/20<br />

3VA5<br />

3VA6<br />

800A<br />

1000A<br />

Selection<br />

3VA5<br />

250A<br />

Part Number<br />

u — — — — 3VA9133-0QE00<br />

— u — — — 3VA9233-0QE00<br />

— — u — — 3VA9243-0QE00<br />

— — — u — 3VA9473-0QE00<br />

— — — — u 3VA9673-0QE00<br />

u — — — — 3VA9134-0QE00<br />

— u — — — 3VA9234-0QE00<br />

— — u — — 3VA9244-0QE00<br />

— — — u — 3VA9474-0QE00<br />

— — — — u 3VA9674-0QE00<br />

u — — — — 3VA9131-0QE10<br />

— u — — — 3VA9231-0QE10<br />

— — u — — 3VA9241-0QE10<br />

— — — u — 3VA9471-0QE10<br />

u — — — — 3VA9131-0QE20<br />

— u — — — 3VA9231-0QE20<br />

— — u — — 3VA9241-0QE20<br />

— — — u — 3VA9471-0QE20<br />

u — — — — 3VA9133-0QF00<br />

— u — — — 3VA9233-0QF00<br />

— — u — — 3VA9243-0QF00<br />

— — — u — 3VA9473-0QF00<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Rear connection studs round<br />

kit of 2 long round studs and<br />

2 short round studs<br />

Rear connection studs round<br />

1 short round studs<br />

Rear connection studs round<br />

1 long round stud<br />

u — — — — 3VA9134-0QF00<br />

— u — — — 3VA9234-0QF00<br />

— — u — — 3VA9244-0QF00<br />

— — — u — 3VA9474-0QF00<br />

u — — — — 3VA9131-0QF10<br />

— u — — — 3VA9231-0QF10<br />

— — u — — 3VA9241-0QF10<br />

— — — u — 3VA9471-0QF10<br />

u — — — — 3VA9131-0QF20<br />

— u — — — 3VA9231-0QF20<br />

— — u — — 3VA9241-0QF20<br />

— — — u — 3VA9471-0QF20<br />

7-94<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA Connection Technology<br />

Revised on 09/30/20<br />

Selection<br />

Phase barriers, terminal covers, and insulating plates<br />

Type<br />

Phase barriers<br />

kit of 2 phase barriers<br />

For molded case circuit breakers/<br />

rated current<br />

3VA5<br />

3VA6<br />

400A<br />

3VA5<br />

3VA6<br />

800A<br />

3VA6<br />

3VA5 3VA5 150A<br />

125A 250A 250A 600A 1000A Part Number<br />

u — — — — 3VA9132-0WA00<br />

— u u — — 3VA9272-0WA00<br />

— — — u — 3VA9472-0WA00<br />

Terminal Cover<br />

with Probe Holes<br />

Part Number<br />

— — — — u 3VA9672-0WA00<br />

Terminal cover for<br />

1-pole breakers<br />

u — — — — 3VA9131-0WD10<br />

Terminal cover for<br />

2-pole breakers<br />

u — — — — 3VA9131-0WD20<br />

Terminal cover for<br />

3-pole breakers<br />

Terminal cover for<br />

4-pole breakers<br />

Terminal cover intermediate<br />

for 3-pole breakers<br />

Terminal cover intermediate<br />

for 4-pole breakers<br />

Terminal cover extended for<br />

2-pole breakers<br />

u — — — — 3VA9131-0WD30 3VA9131-0WD31<br />

— u u — — 3VA9271-0WD30 3VA9271-0WD31<br />

— — — u — 3VA9471-0WD30 3VA9471-0WD31<br />

— — — — u 3VA9671-0WD30<br />

u — — — — 3VA9131-0WD40<br />

— — u — — 3VA9271-0WD40<br />

— — — u — 3VA9471-0WD40<br />

— — — — u 3VA9671-0WD40<br />

— — — — u 3VA9671-0WE30<br />

— — — — u 3VA9671-0WE40<br />

u — — — — 3VA9131-0WF20<br />

Terminal cover extended for<br />

3-pole breakers<br />

Terminal cover extended for<br />

4-pole breakers<br />

u — — — — 3VA9131-0WF30 3VA9131-0WF31<br />

— u u — — 3VA9271-0WF30 3VA9271-0WF31<br />

— — — u — 3VA9471-0WF30 3VA9471-0WF31<br />

— — — — u 3VA9671-0WF30<br />

u — — — — 3VA9131-0WF40<br />

— u u — — 3VA9271-0WF40<br />

— — — u — 3VA9471-0WF40<br />

— — — — u 3VA9671-0WF40<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Terminal cover offset for<br />

3-pole breakers<br />

— — — u — 3VA9471-0WG30<br />

Terminal cover offset for<br />

4-pole breakers<br />

— — — u — 3VA9471-0WG40<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-95


3VA Molded Case Circuit Breakers<br />

3VA Connection Technology<br />

Revised on 05/31/19<br />

Selection<br />

Phase barriers, terminal covers, and insulating plates<br />

For molded case circuit breakers<br />

/ rated current<br />

3VA6<br />

150A<br />

250A<br />

3VA5<br />

3VA6<br />

400A<br />

600A<br />

3VA5 3VA5<br />

Type<br />

125A 250A<br />

Part Number<br />

Rear insulating plate extended for 2-pole breakers u — — — 3VA9131-0WJ20<br />

Rear insulating plate extended for 3-pole breakers u — — — 3VA9131-0WJ30<br />

— u u — 3VA9271-0WJ30<br />

— — — u 3VA9471-0WJ30<br />

Rear insulating plate extended for 4-pole breakers u — — — 3VA9131-0WJ40<br />

— — u — 3VA9271-0WJ40<br />

— — — u 3VA9471-0WJ40<br />

Rear insulating plate offset for 3-pole breakers — — — u 3VA9471-0WK30<br />

7<br />

Rear insulating plate offset for 4-pole breakers — — — u 3VA9471-0WK40<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Control wire tap for busbar<br />

(for fixed mounting)<br />

— u u — 3VA9270-0WC00<br />

— — — u 3VA9470-0WC00<br />

7-96<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA Plug-in and Draw-out Technology<br />

Revised on 10/31/18<br />

Selection<br />

Plug-in socket<br />

Type<br />

Plug-in unit, 3-pole, complete kit<br />

Consists of: Plug-in socket, Plug-in unit,<br />

conversion kit, Mounting screw kit<br />

For molded case circuit breakers /<br />

rated current<br />

3VA61/62<br />

150A/250A<br />

3VA63<br />

400A<br />

3VA64<br />

600A Part Number<br />

u — — 3VA9143-0KP00<br />

— u — 3VA9343-0KP00<br />

— — u 3VA9443-0KP00<br />

Plug-in unit, 4-pole, complete kit<br />

Consists of: Plug-in socket, Plug-in unit,<br />

conversion kit, Mounting screw kit<br />

u — — 3VA9144-0KP00<br />

— u — 3VA9344-0KP00<br />

— — u 3VA9444-0KP00<br />

3 pole 4 pole<br />

Plug-in unit, 3-pole, conversion kit<br />

Consists of: Screw-fastened terminal<br />

covers for molded case circuit breakers,<br />

Plug-in contacts, Cable cage, Autotrip plunger<br />

u — — 3VA9143-0KP10<br />

— u u 3VA9343-0KP10<br />

Plug-in unit, 4-pole, conversion kit<br />

Consists of: Screw-fastened terminal<br />

covers for molded case circuit breakers,<br />

Plug-in contacts, Cable cage, Autotrip plunger<br />

u — — 3VA9144-0KP10<br />

— u u 3VA9344-0KP10<br />

3 pole 4 pole<br />

Draw-out units<br />

Type<br />

Draw-out unit, 3-pole, complete kit<br />

Consists of: Draw-out socket, Draw-out unit, conversion<br />

kit, Mounting screw kit<br />

Draw-out unit, 4-pole, complete kit<br />

Consists of: Draw-out socket, Draw-out unit,<br />

conversion kit, Mounting screw kit<br />

For molded case circuit breakers /<br />

rated current<br />

3VA61/62<br />

150A/250A<br />

3VA63<br />

400A<br />

3VA64<br />

600A Part Number<br />

u — — 3VA9143-0KD00<br />

— u — 3VA9343-0KD00<br />

— — u 3VA9443-0KD00<br />

u — — 3VA9144-0KD00<br />

— u — 3VA9344-0KD00<br />

— — u 3VA9444-0KD00<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Draw-out unit, 3-pole, conversion kit<br />

Consists of: Screw-fastened terminal covers,<br />

Side wall, Plug-in contacts, Cable cage, Autotrip plunger<br />

u — — 3VA9143-0KD10<br />

— u u 3VA9343-0KD10<br />

Draw-out unit, 4-pole, conversion kit<br />

Consists of: Screw-fastened terminal covers,<br />

Side wall, Plug-in contacts, Cable cage, Autotrip plunger<br />

u — — 3VA9144-0KD10<br />

— u u 3VA9344-0KD10<br />

3 pole 4 pole<br />

Note: Crank handle for the drawout unit must be ordered seperately.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-97


3VA Molded Case Circuit Breakers<br />

3VA Plug-in and Draw-out Technology<br />

Revised on 10/31/18<br />

Selection<br />

Accessories<br />

Type<br />

Cable cage for plug-in/draw-out unit 3-/4-<br />

pole (spare part) Cable duct for routing of<br />

the required cables from the internal acc.<br />

on the back of the breaker.<br />

For molded case circuit breakers /<br />

rated current<br />

3VA61/62<br />

150A/250A<br />

3VA63/64<br />

400A/600A<br />

Part Number<br />

u — 3VA9167-0KB02<br />

— u 3VA9367-0KB02<br />

Door feedthrough u — 3VA9147-0KT00<br />

— u 3VA9347-0KT00<br />

Autotrip plunger<br />

Plug-in unit<br />

u — 3VA9267-0KP81<br />

— u 3VA9457-0KP81<br />

Autotrip plunger<br />

Draw-out unit<br />

u — 3VA9267-0KD81<br />

— u 3VA9457-0KD81<br />

Terminal cover for plug-in/draw-out unit,<br />

3-pole (spare part) To provide circuit breaker<br />

touch protection, for mounting on the<br />

molded case cicuit breaker<br />

u — 3VA9143-0KB01<br />

— u 3VA9343-0KB01<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Terminal cover for plug-in/draw-out unit,<br />

4-pole (spare part) To provide circuit breaker<br />

touch protection, for mounting on the<br />

molded case cicuit breaker<br />

Crank handle for draw-out unit<br />

Insulated, including crank holder<br />

u — 3VA9144-0KB01<br />

— u 3VA9344-0KB01<br />

3VA9987-0KD81<br />

7-98<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA Plug-in and Draw-out Technology<br />

Revised on 05/31/19<br />

Selection<br />

Other Accessories<br />

Type<br />

Communication link for draw-out unit<br />

Consists of: Cable kit with 3 special position signaling switches,<br />

connecting cable 3VA9987-0KC10<br />

Part Number<br />

3VA9977-0KC00<br />

Position signaling switches<br />

For draw-out unit<br />

3VA9977-0KB00<br />

Spare connecting cable<br />

To connect the position signaling switches for<br />

communication with the COM060<br />

3VA9987-0KC10<br />

Auxiliary circuit connector<br />

n For draw-out units<br />

3VA9977-0KD80<br />

Auxiliary circuit connector<br />

n For plug-in units<br />

3VA9977-0KP80<br />

7<br />

Cylinder lock (type Ronis)<br />

n Includes a lock with 2 keys<br />

n For locking<br />

n For installation in all rotary operators with shaft stub<br />

n For mounting in the adapter kit for the accessories component<br />

3VA9980-0VL10<br />

3VA9980-0VL30<br />

3VA9980-0VL40<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Cylinder lock adapter for draw-out unit<br />

n For fitting a cylinder lock in the right-hand side wall of the draw-out unit<br />

n To prevent unauthorized withdrawl or insertion of the circuit breaker;<br />

n Circuit breaker can be locked in the CONNECT, TEST, or DISCONNECT position<br />

3VA9970-0LF40<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-99


3VA Molded Case Circuit Breakers<br />

3VA UL Molded Case Circuit Breakers<br />

Accessories and Spare Parts<br />

3VA Communication and Testing/Commissioning Devices<br />

Communication and testing/commissioning devices<br />

Communications overview<br />

■ Design<br />

Revised on 10/31/18<br />

Selection<br />

powermanager power<br />

monitoring software<br />

powerconfig<br />

software<br />

PROFIBUS<br />

Ethernet (Modbus TCP)<br />

I201_19498<br />

SIMATIC S7<br />

PROFINET<br />

3VA-line<br />

T-Connector<br />

T-Connector<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

3VA6 molded case<br />

circuit breaker<br />

3VA6 molded case<br />

circuit breaker<br />

COM800<br />

breaker data server<br />

DSP800<br />

display<br />

COM060<br />

communication module<br />

7KM PAC Switched<br />

Ethernet PROFINET<br />

expansion module<br />

7KM PAC<br />

PROFIBUS DP<br />

expansion module<br />

7KM PAC RS485<br />

MODBUS RTU<br />

expansion module<br />

7-100<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA Communication and Testing/Commissioning Devices<br />

Revised on 08/31/20<br />

Selection<br />

Modules<br />

Type<br />

24 V Module<br />

n 24 V DC<br />

n For mounting in the right-hand accessories<br />

compartment of the 3VA6<br />

n Optional energy supply for the ETU, also includes<br />

contiunous operation of the ETU display and the<br />

metering function of the ETU 8-series<br />

COM060 communication module<br />

n For mounting in the right-hand accessories<br />

compartment of the 3VA6 molded case circuit breaker<br />

(including ETU power supply)<br />

n Communication with the COM800/COM100 breaker<br />

data server via the 3VA-line<br />

n Including a T-Connector<br />

Spare SLC adapter COM060,<br />

24 V module accessory for:<br />

n 3VA61/62 100/150/250<br />

For molded case circuit<br />

breakers / rated current<br />

3VA63/64/65/66<br />

3VA61/62<br />

150A/250 A<br />

400A/600A<br />

800A/1000A Part Number<br />

u — 3VA9177-0TB50<br />

— u 3VA9377-0TB50<br />

u — 3VA9177-0TB10<br />

— u 3VA9377-0TB10<br />

u — 3VA9187-0TB60<br />

Spare SLC adapter COM060,<br />

24 V module accessory for:<br />

n 3VA63/64 400/600<br />

— u 3VA9387-0TB60<br />

Breaker data server<br />

Type<br />

COM800 breaker data server<br />

n 2 terminating resistors<br />

n Central communication module for connecting up to eight 3VA6 molded<br />

case circuit breakers via the 3VA-line<br />

n Ethernet 10/100 Mbit/s interface<br />

n Module slot for plugging on an optional PROFIBUS DP, PROFINET<br />

or RS485 module<br />

Part Number<br />

3VA9977-0TA10<br />

COM100 breaker data server<br />

n 2 terminating resistors<br />

n Central communication module for connecting one 3VA6 molded<br />

case circuit breaker<br />

n Ethernet 10/100 Mbit/s interface<br />

n Module slot for plugging on an optional PROFIBUS DP, PROFINET<br />

or RS485 module<br />

7KM PAC PROFIBUS DP expansion module<br />

n The 7KM PAC PROFIBUS DP expansion module is used for connecting<br />

the COM800/COM100 breaker data server, and the 3VA molded case circuit<br />

breakers conneccted to it, to PROFIBUS DPV1<br />

n The 7KM PAC PROFIBUS DP expansion module provides the status and measured<br />

quantities of the 3VA molded case circuit breaker for the PROFIBUS DP master.<br />

It receives information (e.g. commands) from the PROFIBUS DP master, and<br />

forwards this information to the 3VA molded case circuit breaker<br />

7KM PAC Switched Ethernet PROFINET expansion module<br />

n The 7KM PAC Switched Ethernet PROFINET expansion module is used to connect<br />

the COM800/COM100 breaker data server, and the connected 3VA molded case<br />

circuit breaker, to PROFINET via two Ethernet interfaces<br />

n The 7KM PAC Switched Ethernet PROFINET expansion module provides the status<br />

and measured quantities of the 3VA molded case circuit breaker to PROFINET via<br />

the PROFINET IO, PROFIenergy and Modbus TCP protocols<br />

3VA9977-0TA20<br />

7KM9300-0AB01-0AA0<br />

7KM9300-0AE01-0AA0<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

7KM PAC RS485 Modbus RTU expansion module<br />

n The 7KM PAC RS485 Modbus expansion module is used to connect the COM800/<br />

COM100 breaker data server, and the 3VA molded case circuit breaker connected<br />

to it, to Modbus RTU<br />

n The 7KM PAC RS485 Modbus expansion module provides the status and measured<br />

quantities of the 3VA molded case circuit breaker for the Modbus RTU master.<br />

It receives information (e.g. commands) from the Modbus RTU master, and forwards<br />

this information to the 3VA molded case circuit breaker<br />

7KM9300-0AM00-0AA0<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-101


3VA Molded Case Circuit Breakers<br />

3VA Communication and Testing/Commissioning Devices<br />

Revised on 04/30/20<br />

Selection<br />

Accessories for Communication<br />

Type<br />

T-Connector<br />

n Spare part<br />

n Provides spur line feeder to COM060 and loops to the nextcircuit breaker<br />

n Includes a connection adapter for mounting on the 3VA6 breaker enclosure<br />

DIN rail adapter<br />

For snapping the T-Connector onto a DIN rail<br />

Part Number<br />

3VA9987-0TG10<br />

3VA9987-0TG11<br />

Preassembled T-Connector-to-T-Connector or<br />

T-Connector-to-COM800/ COM100 connecting cable<br />

n 0.4 m long<br />

n 1 m long<br />

n 2 m long<br />

n 4 m long<br />

Preassembled connecting cable for extending the<br />

COM060-to-T-Connector spur line connection<br />

n 0.4 m long<br />

n 0.8 m long<br />

Additional bus terminating resistors<br />

3VA9987-0TC10<br />

3VA9987-0TC20<br />

3VA9987-0TC30<br />

3VA9987-0TC40<br />

3VA9987-0TF20<br />

3VA9987-0TF10<br />

3VA9987-0TE10<br />

Voltage tap to external N conductor<br />

Cable for connecting the neutral point for the metering function of the<br />

8-Series ETU, length 1.5 m<br />

3VA9987-0UC10<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

External current transformer as straight-through transformer. Connection of an external current<br />

transformer for the N conductor for 3-pole 3VA6 molded case circuit breakers for 5-series and<br />

8-series ETUs (ETU850, ETU856, ETU860), including connecting cable<br />

n In = 25 ... 150A<br />

n In = 160 ... 350 A<br />

n In = 400 ... 630 A<br />

n In = 600 ... 1000 A<br />

DSP800 display<br />

n For displaying the status, measured values and parameters of up to 8<br />

3VA6 molded cases circuit breakers<br />

n Connection to the COM800/COM100 via Ethernet for displaying information<br />

of the COM800/COM100 and the connected 3VA6 molded case circuit breaker<br />

3VA9077-0NA10<br />

3VA9177-0NA10<br />

3VA9377-0NA10<br />

3VA9677-0NA10<br />

3VA9977-0TD10<br />

EFB300<br />

n External function box for connection to the ETU of the 3VA6 molded case circuit breaker<br />

n 4 digital outputs for information output, 1 digital input<br />

n ZSI functionality<br />

n S0 interface<br />

n Including cable 1.5 m in length<br />

3VA9977-0UA10<br />

Connecting cable for EFB300 and MMB300. Spare part<br />

n 1.5 m long<br />

n 3.0 m long<br />

n 3.0 m long for 3VA with EFB and RCD820<br />

3VA9987-0UB10<br />

3VA9987-0UB20<br />

3VA9987-0UB30<br />

7-102<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA Communication and Testing/Commissioning Devices<br />

Revised on 02/28/19<br />

Selection<br />

Test devices<br />

Type<br />

TD300<br />

n Connection to the front interface of the ETU<br />

n Test device for activating the ETU and triggering a test trip<br />

Part Number<br />

3VA9977-0MA10<br />

TD500<br />

n Connection to the front interface of the ETU<br />

n Initiation of various test trips (LSING)<br />

n USB interface for connection of a PC using powerconfig<br />

n ETU parameterization<br />

n Including external power supply unit with adapter for Europe, UL and GB<br />

n Including connecting cable to the 3VA6 molded case circuit breaker<br />

3VA9977-0MB10<br />

Spare part: External power supply for TD500<br />

110 ... 240 V AC<br />

3VA9987-0MX10<br />

7<br />

Spare part: Cable for connecting to the TD500 to the 3VA6 molded<br />

case circuit breaker<br />

3VA9977-0MY10<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Maintenance Mode Box<br />

MMB300<br />

n Realization of the NEC 240.87 (Arc Energy Reduction) -> personal protection<br />

during maintenance work<br />

n Switch into maintenance mode by changing the I- and G-protection<br />

to the lowest possible value through an external signal (e.g. door contact)<br />

n Available for all 3VA6 circuit breakers with electronic trip unit<br />

n Daisy chain up to 8 circuit breakers equipped with MMB300<br />

n Additional digital output (D01) for ETU signals available<br />

n Capable of DIN rail mounting<br />

n Includes cable 1.5m in length<br />

3VA9977-0UF10<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-103


3VA Molded Case Circuit Breakers<br />

3VA Accessories for Locking, Blocking and Interlocking<br />

Revised on 09/30/20<br />

Selection<br />

Locking, Blocking, & Interlocking<br />

For molded case circuit breakers/<br />

rated current<br />

3VA6<br />

150A<br />

250A<br />

3VA5<br />

3VA6<br />

400A<br />

600A<br />

3VA5<br />

3VA6<br />

800A<br />

1000A<br />

3VA4 3VA5 3VA5<br />

Type<br />

125A 125A 250A<br />

Part Number<br />

Blocking device for the handle — u — — — — 3VA9038-0LB10<br />

— — u u u — 3VA9378-0LB10<br />

Padlock device for the handle u — — — — — 3VA9038-0LB11<br />

— — u u — — 3VA9138-0LB11<br />

— — — — u — 3VA9338-0LB11<br />

— — — — — u 3VA9578-0LB10<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

3VA5/3VA6<br />

3VA4<br />

Adapter kit for mounting the cylinder lock (type<br />

Ronis) in the accessories compartment of the<br />

molded case circuit breaker Comprising 2 cylinder<br />

lock casings (one for locking and one for interlocking)<br />

and the appropriate mounting module<br />

n To implement an interlock or a lock: select<br />

suitable cylinder lock(s)<br />

n For an interlock: select the same cylinder lock<br />

number<br />

— u — — — — 3VA9137-0LF10<br />

— — u — — — 3VA9237-0LF10<br />

— — — u — — 3VA9147-0LF10<br />

— — — — u — 3VA9347-0LF10<br />

— — — — — u 3VA9577-0LF10<br />

Cylinder lock (type Ronis)<br />

n Includes a lock with 2 keys<br />

n For locking or interlocking<br />

n For installation in all rotary operators with<br />

shaft stub<br />

n For mounting in the adapter kit for the<br />

accessories compartment<br />

n Key 1 (lock number 1) — u u u u — 3VA9980-0VL10<br />

n Key 3 (lock number 3) — u u u u — 3VA9980-0VL30<br />

n Key 4 (lock number 4) — u u u u — 3VA9980-0VL40<br />

Sliding bar<br />

Complete kit for interlocking 2 circuit breakers<br />

n The article number must be ordered 2X to<br />

implement an interlock between 3 breakers<br />

of the same size<br />

Module for handle interlock using a bowden cable<br />

n A separate handle interlock module is required<br />

for each switching device<br />

n A Bowden cable must be ordered separately<br />

— u — — — — 3VA9138-0VF30<br />

— — u — — — 3VA9238-0VF30<br />

— — — u — — 3VA9148-0VF30<br />

— — — — u — 3VA9348-0VF30<br />

— u — — — — 3VA9137-0VF10<br />

— — u — — — 3VA9237-0VF10<br />

— — — u — — 3VA9147-0VF10<br />

— — — — u — 3VA9347-0VF10<br />

— — — — — u 3VA9577-0VF10<br />

Rear interlock with rod<br />

Complete Kit<br />

n Mounting frames are not included in scope of<br />

supply<br />

— u u u u — 3VA9078-0VM10<br />

Rear interlock with rod<br />

Complete Kit<br />

n Mounting frames are included in scope of<br />

supply<br />

— — — — — u 3VA9578-0VM10<br />

Rear interlock with rod<br />

Complete Kit for plug-in/draw-out unit<br />

n Mounting frames are not included in scope of<br />

supply<br />

— u u u u — 3VA9078-0VM30<br />

7-104<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA Accessories for Locking, Blocking and Interlocking<br />

Revised on 09/30/20<br />

Selection<br />

Locking, Blocking, & Interlocking<br />

For molded case circuit breakers/<br />

rated current<br />

3VA6<br />

150A<br />

250A<br />

3VA5<br />

3VA6<br />

400A<br />

600A<br />

3VA5<br />

3VA6<br />

800A<br />

1000A<br />

3VA5 3VA5<br />

Type<br />

125A 250A<br />

Part Number<br />

Bowden cable<br />

n Length 0.6 m u u u u — 3VA9980-0VC10<br />

n Length 1.0 m u u u u — 3VA9980-0VC20<br />

n Length 1.5 m u u u u — 3VA9980-0VC30<br />

Mounting frame for rear interlock with rod ab<br />

The following are required for the complete<br />

mounting frame kit:<br />

n Profile poles u u u u — 3VA9078-0VK10<br />

n Mounting Plates u — — — — 3VA9138-0VK20<br />

— u — — — 3VA9238-0VK20<br />

— — u — — 3VA9248-0VK20<br />

— — — u — 3VA9448-0VK20<br />

Cover frame for door cut-out<br />

Cover frame for door cut-out for molded<br />

case circuit breaker<br />

n 3-pole, door cut-out without trip unit<br />

Cover frame for door cut-out for molded<br />

case circuit breaker<br />

n 3-pole, door cut-out with trip unit<br />

Cover frame for door cut-out for molded<br />

case circuit breaker<br />

n 4-pole, door cut-out without trip unit<br />

Cover frame for door cut-out for molded<br />

case circuit breaker<br />

n 4-pole, door cut-out with trip unit<br />

Cover frame for door cut-out for MO320<br />

motor operators<br />

Cover frame for door cut-out for front<br />

mounted rotary operators<br />

Cover frame for door cut-out for front<br />

mounted rotary operator with door interlock<br />

Cover frame for door cut-out for door<br />

feedthrough<br />

u — — — — 3VA9033-0SB10<br />

— u u — — 3VA9143-0SB10<br />

— — — u — 3VA9373-0SB10<br />

— — — — u 3VA9583-0SB10<br />

u — — — — 3VA9033-0SB20<br />

— u — — — 3VA9233-0SB20<br />

— — u — — 3VA9143-0SB20<br />

— — — u — 3VA9343-0SB20<br />

— — — — u 3VA9583-0SB20<br />

u — — — — 3VA9034-0SB10<br />

— u u — — 3VA9144-0SB10<br />

— — — u — 3VA9374-0SB10<br />

— — — — u 3VA9584-0SB10<br />

u — — — — 3VA9034-0SB20<br />

— u — — — 3VA9234-0SB20<br />

— — u — — 3VA9144-0SB20<br />

— — — u — 3VA9344-0SB20<br />

— — — — u 3VA9584-0SB20<br />

u — — — — 3VA9033-0SB10<br />

— u u — — 3VA9237-0SB30<br />

— — — u — 3VA9377-0SB30<br />

u — — — — 3VA9033-0SB10<br />

— u u — — 3VA9143-0SB10<br />

— — — u — 3VA9373-0SB10<br />

— — — u — 3VA9377-0SB30<br />

— — — — u 3VA9583-0SB50<br />

— u u — — 3VA9233-0SB20<br />

— — — u — 3VA9333-0SB20<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Labeling plate for cover frame<br />

3VA9087-0SX10<br />

a 2 mounting plates are required. They are screwed onto<br />

the profile rail that can be ordered above. Different<br />

breakers can be mutually interlocked.<br />

b Breakers with plug-in unit can be mounted on the<br />

mounting plates, but the profile rails cannot be used.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-105


3VA Molded Case Circuit Breakers<br />

3VA Accessories and Spare Parts<br />

Revised on 10/15/20<br />

Selection<br />

Other accessories<br />

Type<br />

Busbar adapter system with 60 mm<br />

busbar center-to-center spacing<br />

3-pole<br />

For molded case circuit breakers/<br />

rated current<br />

3VA5 3VA5<br />

3VA6 3VA6 3VA6<br />

3VA5 3VA5 150A 400A 800A<br />

125A 250A 250A 600A 1000A Part Number<br />

u — — — — 8US1211-4SS00 a<br />

— u u — — 8US1213-4AP03 b<br />

— — — u — 8US1213-4AH04 b<br />

Busbar adapter system with 60 mm<br />

busbar center to center spacing,<br />

bottom connection, 3-pole<br />

Busbar adapter designed for 3VA breaker<br />

used as a main<br />

u — — — — 8US1215-4SS00<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Metric mounting screw kit<br />

u — — — — 3VA9151-0SS10<br />

For fixed mounted breakers 1-pole<br />

Metric mounting screw kit (2 pcs)<br />

u — — — — 3VA9116-0SS10<br />

For fixed mounted breakers 2-pole<br />

Metric mounting screw kit (4 pcs)<br />

u u — — — 3VA9114-0SS10<br />

For fixed mounted breakers 3-,4-pole<br />

Metric mounting screw kit<br />

— — u — — 3VA9126-0SS10<br />

For fixed mounted breakers 3-pole<br />

Metric mounting screw kit<br />

— — u — — 3VA9124-0SS10<br />

For fixed mounted breakers 4-pole<br />

Metric mounting screw kit<br />

— — — u — 3VA9328-0SS10<br />

For fixed mounted breakers 3-,4-pole<br />

Metric mounting screw kit<br />

— — u — — 3VA9124-0SS10<br />

For plug-in and draw-out unit<br />

SAE mounting screw kit (2 pcs)<br />

u — — — — 3VA9151-0SS00<br />

For fixed mounted breakers 1-pole<br />

SAE Mounting screw kit (2 pcs)<br />

u — — — — 3VA9156-0SS00<br />

For fixed mounted breakers 2-,3-pole<br />

SAE Mounting screw kit (4 pcs)<br />

u — — — — 3VA9154-0SS00<br />

For fixed mounting breakers 4-pole<br />

SAE Mounting screw kit (4 pcs)<br />

— u u — — 3VA9164-0SS00<br />

For fixed mounted breakers 3-,4-pole and 3VA6<br />

150/250 plug-in and draw-out units<br />

SAE Mounting screw kit (2 pcs)<br />

— u u — — 3VA9166-0SS00<br />

For fixed mounted breakers 2-,3-pole<br />

SAE Mounting screw kit (4 pcs)<br />

— — — u — 3VA9368-0SS00<br />

For fixed mounted breakers 2-,3-,4-pole and 3VA6<br />

400/600 plug-in and draw-out units<br />

Replacement handle extension accessory — — — u — 3VA9487-0SC10<br />

a Busbar adapter designed for 3VA breaker used as<br />

a feeder.<br />

b Busbar adapter designed for 3VA breaker used as either<br />

a main or feeder.<br />

7-106<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Molded Case Circuit Breakers<br />

3VA Accessory Electrical Requirements<br />

Auxiliary switches electrical requirements<br />

Revised on 10/31/18<br />

Technical data<br />

Internal accessories<br />

Auxiliary switches and<br />

alarm switches HQ<br />

Auxiliary switches and alarm<br />

switches HQ_electronic<br />

Auxiliary switches and<br />

alarm switches HP<br />

Rated<br />

operational<br />

voltage<br />

Conventional<br />

free-air thermal<br />

current<br />

IEC<br />

Ratings<br />

Listed<br />

Max. rated Inductive load<br />

current (UL/CSA) (0.75-0.8 AC)<br />

AUX LCS TAS EAS AUX LCS TAS EAS AUX LCS TAS<br />

U e V AC 240 24 600<br />

50 Hz<br />

V DC 250 24 250<br />

th = e A 6 0.3 10<br />

AC-12 12 V A 6 0.3 10<br />

24 V A 6 0.3 10<br />

48 V A 6 -- 10<br />

125 V A 6 -- 10<br />

220/240 V A 6 -- 10<br />

380/440 V A -- -- 6<br />

600 V A -- -- 2<br />

AC-15 12 V A 3 0.3 6<br />

2/4 V A 3 0.3 6<br />

48 V A 3 -- 6<br />

125 V A 3 -- 6<br />

220/240 V A 3 -- 6<br />

380/440 V A -- -- 2<br />

600 V A -- -- 0.6<br />

DC-12 12 V A 6 0.1 6<br />

24 V A 4 0.1 6<br />

48 V A 2 -- 2<br />

110 V A 0.5 -- 0.6<br />

250 V A 0.25 -- 0.3<br />

DC-13 12 V A 1 0.07 3<br />

24 V A 0.8 0.07 3<br />

48 V A 0.4 -- 0.8<br />

110 V A 0.2 -- 0.2<br />

250 V A 0.1 -- 0.1<br />

24 V A 3 0.3 6<br />

300 V A 3 -- 6<br />

600 V A -- -- 6<br />

Pilot duty (AC) 24 V A 3 -- 6<br />

127 V A 3 -- 6<br />

240 V A 3 -- 3<br />

480 V A -- -- 1.5<br />

600 V A -- -- 1.2<br />

Resistive load (DC) 24 V A 0.25 0.1 0.3<br />

250 V A 0.25 -- 0.3<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Resistive load - pilot<br />

duty sequence (DC)<br />

125 V A 0.6 -- 0.9<br />

250 V A 0.3 -- 0.55<br />

Minimum load At 24 mA 70 0.5 70<br />

V DC<br />

At 5 V DC mA -- 1 --<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-107


3VA Molded Case Circuit Breakers<br />

3VA Accessory Electrical Requirements<br />

Revised on 10/15/20<br />

Technical data<br />

Shunt trip/undervoltage electrical requirements<br />

Shunt trip left<br />

STL<br />

Shunt trip<br />

flexible STF<br />

Undervoltage<br />

releases UVR<br />

Universal<br />

release UNI<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Power consumption U e 12 V DC W 50 -- -- --<br />

24 50 V AC/60 Hz VA 50 -- -- --<br />

24 ... 30 V DC W 7 ... 50 -- -- --<br />

48 ... 60 50 V AC/60 Hz VA 15 ... 20 -- -- --<br />

48 ... 60 V DC W 20 ... 30 -- -- --<br />

110 ... 127 50 V AC/60 Hz VA 30 ... 40 -- -- --<br />

110 ... 127 V DC W 30 ... 40 -- -- --<br />

208 ... 277 50 V AC/60 Hz VA 16 ... 35 -- -- --<br />

220 ... 250 V DC W 28 ... 35 -- -- --<br />

380 ... 600 50 V AC/60 Hz VA 10 ... 30 -- -- --<br />

24 50 V AC/60 Hz VA -- 300 -- --<br />

48 ... 60 50 V AC/60 Hz VA -- 340 ... 600 -- --<br />

110 ... 127 50 V AC/60 Hz VA -- 500 ... 650 -- --<br />

208 ... 277 50 V AC/60 Hz VA -- 360 ... 650 -- --<br />

380 ... 500 50 V AC/60 Hz VA -- 330 ... 600 -- --<br />

600 50 V AC/60 Hz VA -- 300 -- --<br />

12 ... 250 V DC W -- -- < 2.5 --<br />

24 ... 230 50 V AC/60 Hz VA -- -- < 2 --<br />

380 ... 480 50 V AC/60 Hz VA -- -- < 2.5 --<br />

12 V DC (Cat II;<br />

PELV/SELV)<br />

24 V DC (Cat II;<br />

PELV/SELV)<br />

48 V DC (Cat II;<br />

PELV/SELV)<br />

W -- -- -- UVR: < 2.5<br />

SHT: 20<br />

W -- -- -- UVR: < 2.5<br />

SHT: 20<br />

W -- -- -- UVR: < 2.5<br />

SHT: 20<br />

Rated impulse withstand<br />

U imp kV 6 4 0.5<br />

voltage<br />

Making current I max at V 1.5 A/24 V AC 18 A/24 V AC 5 mA/480 V 1.5 A/24 V<br />

Maximum tripping time ms < 10<br />

Service life Electrical trips 8500<br />

Mechanical switching cycles of the circuit breaker 25000<br />

Priority over other control<br />

Given<br />

signals<br />

Degree of protection Lid of the accessories compartment closed IP40<br />

Lid of the accessories compartment open IP 20<br />

Minimum signal duration ms 40 40 -- 40<br />

Response voltage shunt<br />

trip<br />

Undervoltage release<br />

response voltage<br />

Pick-up (circuit<br />

breaker trips)<br />

Pick-up (circuit<br />

breaker can be<br />

switched on)<br />

Pick-up (circuit<br />

breaker trips)<br />

Us/V % 70 ... 110 -- 70 ... 110<br />

Us/V % -- -- 85 ... 110<br />

Us/V % -- -- 35 ... 70<br />

Tripping frequency Trips per hour Unlimited 120 Unlimited<br />

Can be used for electrical<br />

interlocking of molded case<br />

circuit breakers<br />

No No Yes<br />

7-108<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


which indicates ON and OFF and, via LED, whether the<br />

reaker has tripped (TRIP). It is thus possible to identify ■ Design<br />

tching position of the molded case circuit breaker at any<br />

• The MO320 motor operator is simply snapped into Revised position on on 10/15/20<br />

a mounting frame that is installed instead of the accessories<br />

ferent reset modes 3VA can Molded be selected, Case i.e. in one Circuit mode, the Breakers<br />

lid of the molded case circuit breaker.<br />

r resets the molded case circuit breaker automatically<br />

he other, it waits for confirmation by an OFF signal before<br />

the breaker. 3VA Accessory Electrical Requirements ■ Technical specifications<br />

Technical data<br />

more, the motor operator can be locked in the<br />

MO320 motor operator 3VA5 3VA5 3VA6<br />

sition by means DC breaking of several padlocks. capacity according to UL489<br />

125 A 250 A 150 A/ 400 A/<br />

250 A 600 A<br />

Degree of protection NEMA 1<br />

Applies to MCCBs Rated control in line supply protection voltage and 24 V ... 60 V - DC 2 current (0.85 ... 1.26) paths with a 3-pole circuit<br />

MCS, if protected (operating by a range suitable of control overcurrent 110 V ... 230 V<br />

breaker<br />

AC/<br />

or<br />

protection device. supply voltage)<br />

110 V ... 250 - V 3 DC current (0.85 ... paths 1.1) with a 4-pole molded<br />

With an non-grounded Rating system, all poles 250 W, max. 500 case W (60 circuit ms) breaker in series can take<br />

must always Make be switched time, typically off. < 800 ms < 1000 over ms the switch-off < 1700 ms<br />

The grounded Break pole time, must typically always be assigned < 800 ms < Further 1000 ms wirings are available < 1400 mson request.<br />

to the individual current path so that in the<br />

event of an ground fault at least...<br />

3VA51 3VA52 3VA53 3VA54<br />

125 A<br />

(15- 125 A)<br />

250 A<br />

(40 – 250 A)<br />

400 A<br />

(200 - 400 A)<br />

DC single-pole<br />

disconnection<br />

DC all-pole<br />

disconnection<br />

600 A<br />

(450 – 600 A) Grounded a Grounded a Isolated<br />

on and ordering data DC breaking capacity acc. UL489 in kA<br />

S M H M H C M H C M H C<br />

Version<br />

For molded case circuit DT Article No. Price PE PS*/ PG<br />

125 V 250 V 250 V breakers/ 250 V<br />

b<br />

per PU (UNIT, P. unit<br />

rated current<br />

SET,<br />

3VA5 3VA5 3VA6 3VA6<br />

M)<br />

125 A 250 A 150 A, 400 A, <br />

Load 250 A Load 600<br />

Load<br />

A Load Load<br />

Load Load Load Load Load<br />

Load<br />

Load Load Load Load Load Load Load Load Load<br />

operators 14 25 30 50 85 100 50 85 100 50 85 100<br />

Load<br />

Load Load<br />

Motor operators without stored energy feature <br />

250 V (MO320) 500 V 500 V 500 V<br />

Versions<br />

• 24 ... 60 V DC ✓ -- -- -- 3VA9137-0HA10 1 1 unit 1CB<br />

-- ✓ ✓ -- 3VA9277-0HA10 1 1 unit 1CB<br />

-- -- Load -- ✓Load<br />

Load Load 3VA9447-0HA10 Load<br />

Load Load Load Load 1 Load 1 unit 1CB<br />

Load Load Load Load Load Load<br />

• 110 ... 230 V AC, <br />

✓ --<br />

Load<br />

-- -- Load Load<br />

3VA9137-0HA20<br />

Load<br />

50 85 100 50 85 100 50 85 100 50 85 100<br />

1 1 unit 1CB<br />

7-0HA10<br />

110 ... 250 V DC<br />

-- ✓ ✓ -- 3VA9277-0HA20 1 1 unit 1CB<br />

500 V 750 V 600 V -- -- 600 V -- ✓ 3VA9447-0HA20 1 1 unit 1CB<br />

Load Load Load<br />

Load Load Loa<br />

Load<br />

Load Loa<br />

G<br />

7<br />

50 85 100 50 85 100<br />

750 V 750 V<br />

Load<br />

Load Load<br />

50 85 100 50 85 100 6 6 10 6 6 10<br />

Load Load Load Load<br />

Load Load Load<br />

Load<br />

Load Load<br />

Load<br />

Load GF<br />

GF GF<br />

GF<br />

Load<br />

GF<br />

GF<br />

Load Load Load Load<br />

Load<br />

Load Load Load Load Load<br />

Load Load<br />

Load GF GF<br />

GF<br />

GF GF<br />

GF<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Load Load Loa<br />

Load Load Lo<br />

600 V 1000 V 750 V 750 V<br />

50 85 100 50 85 100<br />

1000 V 1000 V<br />

Load<br />

Load Load<br />

Load Load Load Load<br />

Load Load Load<br />

—<br />

Load<br />

Load Load<br />

GF<br />

GF GF<br />

Load Load<br />

Load GF<br />

Lo G<br />

GF<br />

50 85 100 50 85 100 6 6 10 6 6 10<br />

Siemens · 04/<strong>2017</strong><br />

GF ground fault monitoring<br />

a Minus pole grounded<br />

b Also covers 1-pole circuit breaker in 2-pole frame<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-109


Sentron Molded Case Circuit Breakers<br />

Catalog Numbering System<br />

Revised on 02/06/18<br />

Selection/Application<br />

If used on 250A frame and above means<br />

non-interchangeable trip breaker with<br />

factory assembled frame and trip. Solid<br />

state trip and current limiting (S or C in<br />

first character) are non-interchangeable<br />

only, and the “X” is omitted.<br />

X D<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Trip Unit Type<br />

— Omitted – Thermal-Magnetic<br />

S — Sensitrip ® Electronic Trip<br />

Sentron Series Type/Interrupting Range<br />

— Omitted – Standard Rating<br />

H — High IC Rating<br />

HH — Extra High IC Rating<br />

C — Highest IC Rating and Current Limiting<br />

Frame Identifier<br />

E — Type ED M — Type MD<br />

F — Type FD N — Type ND<br />

J — Type JD P — Type PD<br />

L — Type LD R — Type RD<br />

LM — Type LMD<br />

Maximum Voltage<br />

2 — 240 Vac<br />

4 — 480 Vac<br />

6 — 600 Vac<br />

Number of Poles<br />

1<br />

2<br />

3<br />

A — used to indicate advanced electronic trip unit with maintenance mode capability (always 3 poles)<br />

B — used to indicate basic electronic trip unit (always 3 poles)<br />

(Specific Application Type)<br />

B — Standard 40°C Breaker<br />

M — Calibrated for 50°C Application<br />

F — Frame Only<br />

T — 40°C Trip Unit Only<br />

W — 50°C Trip Unit Only<br />

S — Molded Case Switch<br />

L — Low Instantaneous Range ETI Breaker<br />

A — Standard Range ETI Breaker<br />

H — High Instantaneous Range ETI Breaker<br />

Maximum Continuous Current Rating<br />

ED Frame — 015, 020, 025, 030, 035, 040, 045, 050, 060, 070, 080, 090, 100, 110, 125<br />

FD Frame — 070, 080, 090, 100, 110, 125, 150, 175, 200, 225, 250<br />

JD Frame — 200, 225, 250, 300, 350, 400<br />

LD Frame — 250, 300, 350, 400, 450, 500, 600<br />

LMD Frame — 500, 600, 700, 800<br />

MD Frame — 500, 600, 700, 800<br />

ND Frame — 900, 100 (1000A), 120 (1200A)<br />

PD Frame — 120 (1200A), 140 (1400A), 160 (1600A)<br />

RD Frame — 160 (1600A), 180 (1800A), 200 (2000A)<br />

Suffix<br />

L — where applicable indicates a breaker shipped with line/loads lugs installed<br />

A — used with a switch to show automatic self protection<br />

Y — 400 Hertz<br />

H — 100% rated<br />

P — Load side lugs only<br />

NAV — Naval Ratings<br />

NOTE:<br />

— Position omitted if not used.<br />

7-110<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Molded Case Circuit Breakers<br />

ED 125A Frame Sentron Series<br />

Revised on 06/30/19<br />

Selection<br />

Ordering Instructions<br />

All ED Frame Sentron circuit breakers are supplied with load side lugs. If line side lugs are required, add ”L” suffix to catalog number.<br />

Consult Siemens sales office for any addditional charge<br />

50°C Calibration, 400HZ - see page 7-156. All ED frame circuit breakers may be reverse connected<br />

Type ED2 e<br />

Note: ED frame circuit breakers qualified to UL 489<br />

Supplement SB “Naval”— See page 7-156 for<br />

additional information<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

aCSA Certified only (Not UL)<br />

Blue Label<br />

1-Pole 2-Pole 3-Pole<br />

Continuous<br />

125V DC<br />

Current Rating 120V AC 125V DC 240V AC 250V DC 240V AC<br />

@ 40°C<br />

Catalog Number Catalog Number Catalog Number<br />

015 ED21B015 d n ED22B015 ED23B015<br />

020 ED21B020 d n ED22B020 ED23B020<br />

25 ED21B025n ED22B025n ED23B025n<br />

030 ED21B030n ED22B030 ED23B030<br />

35 ED21B035n ED22B035n ED23B035n<br />

040 ED21B040n ED22B040 ED23B040<br />

45 ED21B045n ED22B045n ED23B045n<br />

050 ED21B050n ED22B050 ED23B050<br />

060 ED21B060n ED22B060 ED23B060<br />

070 ED21B070n ED22B070 ED23B070<br />

80 ED21B080n ED22B080n ED23B080<br />

90 ED21B090n ED22B090n ED23B090n<br />

100 ED21B100n ED22B100 ED23B100<br />

Type ED4 e<br />

Continuous<br />

Current Rating<br />

@ 40°C<br />

Blue Label<br />

1-Pole 2-Pole 3-Pole<br />

120V AC<br />

277V AC 125V DC 480V AC 250V DC 480V AC<br />

Catalog Number Catalog Number Catalog Number<br />

015 ED41B015 d — ED43B015<br />

020 ED41B020 d ED42B020 ED43B020<br />

025 ED41B025 ED42B025 ED43B025<br />

030 ED41B030 ED42B030 ED43B030<br />

035 ED41B035n ED42B035n ED43B035<br />

040 ED41B040 ED42B040 ED43B040<br />

045 ED41B045n ED42B045n ED43B045<br />

050 ED41B050 ED42B050 ED43B050<br />

060 ED41B060 ED42B060 ED43B060<br />

070 ED41B070 ED42B070 ED43B070<br />

080 ED41B080n ED42B080n ED43B080<br />

090 ED41B090n ED42B090n ED43B090<br />

100 ED41B100 ED42B100 ED43B100<br />

110 ED41B110 ED42B110n ED43B110<br />

125 — ED42B125 ED43B125<br />

Type ED6 e<br />

Blue Label<br />

Continuous<br />

1-Pole 2-Pole 3-Pole 3-Pole<br />

Current<br />

Rating 347V AC 600V AC 250V DC 600V AC 500V DC 600V DC<br />

@ 40°C Catalog Number Catalog Number Catalog Number Catalog Number<br />

15 ED61B015 — — ED63D015L<br />

20 ED61B020 ED62B020 ED63B020 ED63D020L<br />

25 ED61B025 ED62B025n ED63B025 ED63D025L<br />

30 ED61B030 ED62B030 ED63B030 ED63D030L<br />

35 ED61B035 — ED63B035 ED63D035L<br />

40 ED61B040 — ED63B040 ED63D040L<br />

45 ED61B045n — ED63B045 ED63D045L<br />

50 ED61B050 — ED63B050 ED63D050L<br />

60 ED61B060 — ED63B060 ED63D060L<br />

70 ED61B070n — ED63B070 —<br />

80 ED61B080 — ED63B080 —<br />

90 ED61B090 — ED63B090 —<br />

100 ED61B100n — ED63B100 —<br />

110 — — ED63B110 —<br />

125 — — ED63B125 —<br />

bFor CED types and all 110–125 ampere ED frames.<br />

cSee Note: A, page 7-153.<br />

dSWD rated.<br />

e HACR rated.<br />

Not for use with HHED6 breakers.<br />

Shipping Weights<br />

Number of Number per Shipping<br />

Poles Carton Weight (lbs.)<br />

ED2, ED4, ED6, HED4, HHED6<br />

1 30 38<br />

2 10 25<br />

3 10 38<br />

CED6<br />

2 5 20<br />

3 5 30<br />

Lugs<br />

Ampere<br />

Rating<br />

No. of<br />

Poles<br />

Catalog<br />

Number<br />

Aluminum Body Lugs<br />

All 15–25A 1, 2, 3<br />

Line/Load<br />

SA1E025<br />

All 30–100A 1, 2, 3<br />

Line Side<br />

LN1E100<br />

ED2, 4, 6, HED4<br />

30-60A<br />

ED2, 4, 6, HED4<br />

70-100A<br />

ED2, 4, 6, HED4,<br />

HHED6<br />

30-100A<br />

1<br />

1<br />

2, 3<br />

All 110, 125A 2, 3<br />

Copper Body Lugs<br />

All 30–125A 1, 2, 3<br />

Load Side<br />

LD1E060<br />

Load Side<br />

LD1E100<br />

Load Side<br />

LN1E100<br />

Line/Load<br />

TA1E6125<br />

Wire<br />

Range<br />

#14–#10 Cu<br />

#12–#10 Al<br />

Modifications page 7-156<br />

Enclosures Section 6<br />

Accessories pages 7-113 and 7-160 to 7-165<br />

#10–1/0 Cu/Al<br />

#10–#4 Cu/Al<br />

#6–#1/0 Cu/Al<br />

#10–1/0 Cu/Al<br />

#3–3/0 Cu<br />

#1–2/0 Al<br />

Line/Load #10–1/0 Cu<br />

TC1ED6150 c only<br />

Compression Lugs<br />

All ED, HED, HHED, CED CCE125 2/0<br />

Enclosures (Neutral Included) <br />

Type<br />

Catalog Number<br />

1 (Surface) E2N1S (15–100A)<br />

1 (Flush) E2N1F (15–100A)<br />

3R<br />

E2N3R (15–100A)<br />

4–4X ED6SS4 (15–125A)<br />

7–9 EA (15–60A)<br />

7–9 EB (70–100A)<br />

12 E2N12 (15–100A)<br />

1 (Surface) CED6N1S b<br />

1 (Flush) CED6N1F b<br />

3R<br />

CED6N3R b<br />

12 CED6N12 b<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-111


Molded Case Circuit Breakers<br />

ED 125A Frame Sentron Series<br />

Revised on 07/31/19<br />

Selection/Dimensions<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Type HED4 <br />

Black Label<br />

1-Pole 2-Pole 3-Pole<br />

Continuous<br />

Current Rating 277V AC 125V DC 480V AC 250V DC 480V AC<br />

@ 40°C<br />

Catalog Number Catalog Number Catalog Number<br />

015 HED41B015 a HED42B015 HED43B015<br />

020 HED41B020 a HED42B020 HED43B020<br />

25 HED41B025 HED42B025n HED43B025<br />

030 HED41B030 HED42B030 HED43B030<br />

35 HED41B035n HED42B035n HED43B035<br />

040 HED41B040 HED42B040 HED43B040<br />

45 HED41B045n HED42B045n HED43B045<br />

050 HED41B050n HED42B050 HED43B050<br />

060 HED41B060n HED42B060n HED43B060<br />

070 HED41B070n HED42B070n HED43B070<br />

80 HED41B080n HED42B080n HED43B080<br />

90 HED41B090n HED42B090n HED43B090<br />

100 HED41B100n HED42B100n HED43B100<br />

110 — HED42B110n HED43B110<br />

125 — HED42B125n HED43B125<br />

Type HHED6 Black Label Type CED6 Red Label<br />

Continuous<br />

Current<br />

Rating<br />

@ 40°C<br />

3-Pole 2-Pole 3-Pole<br />

600V AC<br />

600V AC,<br />

250V DC<br />

600V AC,<br />

500V DC b<br />

Catalog Number Catalog Number Catalog Number<br />

015 HHED63B015A CED62B015 CED63B015<br />

020 HHED63B020 CED62B020n CED63B020<br />

025 HHED63B025 — —<br />

030 HHED63B030 CED62B030n CED63B030<br />

035 HHED63B035 — —<br />

040 HHED63B040 — CED63B040<br />

045 HHED63B045 — —<br />

050 HHED63B050 — CED63B050<br />

060 — CED62B060n CED63B060<br />

070 — CED62B070n CED63B070<br />

080 — CED62B080n CED63B080<br />

090 — CED62B090n CED63B090<br />

100 — CED62B100n CED63B100<br />

110 — — CED63B110n<br />

125 — CED62B125n CED63B125<br />

Interrupting Ratings<br />

Fuseless Current Limiting<br />

FIGURE1 - ED, HED, HHED<br />

<br />

H<br />

<br />

<br />

W3<br />

W1<br />

W2<br />

1-POLE 2-POLE 3-POLE<br />

FIGURE 2 - CED (3-Pole shown)<br />

<br />

H<br />

Dimensions (in inches)<br />

<br />

<br />

<br />

W2, W3<br />

Breaker Type W1 W2 W3 H D D1<br />

Figure 1<br />

ED2, ED4,<br />

ED6, HED4,<br />

1 2 3 6.35 3.92 4.56<br />

ED6 ETI c<br />

Figure 1<br />

HHED6<br />

— 2 3 6.53 3.92 4.56<br />

Figure 2<br />

CED6,<br />

CED6 ETI c — 2 3 9.58 3.92 4.56<br />

UL 489 AIR (File #E10848) IEC 947-2<br />

RMS Symmetrical Amperes (KA)<br />

Volts AC (50/60Hz)<br />

Volts AC Volts DC 220/240 380/415 500<br />

Breaker Type 120 240 277 347 480 600 125 250 500 600 lcu lcs lcu lcs lcu lcs<br />

ED2 (1-P) 10 — — — — — 5 — — — — — — — — —<br />

ED2 (2, 3-P) — 10 — — — — — 5 (2-P) — — — — — — — —<br />

ED4 (1-P) 65 — 22 — — — 30 — — — — — — — — —<br />

ED4 (2, 3-P) — 65 — — 18 — — 30 (2-P) — — — — — — — —<br />

ED6 (1P) — — — 30 — — — 30 — — — — — — — —<br />

ED6 (2, 3-P) — 65 — — 25 18 — — 18 (3-P) — 65 17 35 9 18 5<br />

ED6 (3-P) — — — — — — — — — 10 g — — — — — —<br />

HED4 (1-P)<br />

(15–30A)<br />

100 — 65 — — — 30 — — — — — — — — —<br />

HED4 (1-P)<br />

(35–100A)<br />

100 — 25 — — — 30 — — — — — — — — —<br />

HED4 (2, 3-P) — 100 — — 42 — — 30 (2-P) — — — — — — — —<br />

HHED6 (2, 3-P) — 100 — — 65 18 — — — — — — — — — —<br />

CED6 (2, 3-P) — 200 — — 200 100 — 50 (2-P) 30 (3-P) — — — — — — —<br />

<br />

<br />

<br />

D<br />

D1<br />

<br />

<br />

D1<br />

<br />

D<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

aSWD rated.<br />

bWhen wired as shown on page 7-4, this circuit breaker is<br />

UL listed and rated for use on 500V DC ungrounded UPS<br />

systems.<br />

c ED6-ETI, CED6-ETI, see page 7-140 for ordering<br />

information.<br />

d Single Pole 15-30A 30KA @ 347V non-UL.<br />

35-100A 18KA @ 347V non-UL.<br />

e HACR rated.<br />

f HHED63B015A is rated 18KAIC at 600/347V.<br />

g 600VDC only applies to ED63D___ breakers<br />

7-112<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

Accessories<br />

Revised on 12/31/19<br />

Selection<br />

Accessories for:<br />

ED 125A Frame<br />

Combinations<br />

Available only when ordered together.<br />

Only one module can be added to a<br />

breaker. Additional accessories, which<br />

always attach to the left pole, cannot be<br />

added to the combination later. Adds 1<br />

inch pole space.<br />

Equipment<br />

Ground Sensing<br />

A field addable kit containing 30mA or<br />

5 mA ground fault accessory module,<br />

current transformer with 24 inch leads,<br />

and current transformer mounting<br />

equipment. Current transformer to<br />

mount in gutter of lighting panel or<br />

any control panel. Accessory module<br />

operates from separate 120V control<br />

power source.<br />

Both 30MA and 5MA devices are<br />

equipment protection devices only.<br />

Do not use for personnel protection.<br />

GF01ED60<br />

Shunt Trip Combinations<br />

1 Shunt Trip<br />

Control 1 Shunt Trip and 1 Auxiliary Switch 1 Shunt Trip and 1 Shunt Trip and 2<br />

Voltage 1 Shunt Trip 1 Auxiliary Switch and 1 Alarm Switch 1 Alarm Switch Auxiliary Switches<br />

AC DC Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number<br />

024 S17ED60 — — — —<br />

048 S18ED60 — — — —<br />

120 S01ED60 S01ED62A S01ED62AB S01ED62B S01ED62AA<br />

208 — S02ED62As S02ED62ABs S02ED62Bs S02ED62AAs<br />

240 S03ED60 S03ED62A S03ED62AB S03ED62Bs S03ED62AAs<br />

277 S15ED60s S15ED64As S15ED64ABs S15ED64Bs —<br />

480 S04ED60 S04ED64As S04ED64ABs S04ED64Bs —<br />

012 S16ED60s S16ED62As — — —<br />

024 S07ED60 S07ED62A S07ED62ABs S07ED62Bs S07ED62AAs<br />

048 S09ED60s S09ED62As S09ED62ABs S09ED62Bs S09ED62AAs<br />

125 S11ED60s S11ED62As S11ED62ABs S11ED62Bs S11ED62AAs<br />

250 S13ED60s S13ED62As S13ED62ABs S13ED62Bs S13ED62AAs<br />

Undervoltage Trip Combinations<br />

1 Undervoltage Trip<br />

1 Undervoltage and 1 Auxiliary 1 Undervoltage 1 Undervoltage<br />

Control 1 Undervoltage Trip and Switch and Trip and Trip and 2<br />

Voltage Trip 1 Auxiliary Switch 1 Alarm Switch 1 Alarm Switch Auxiliary Switches<br />

AC DC Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number<br />

120 U01ED60 U01ED62A U01ED62ABs U01ED62Bs U01ED62AAs<br />

208 U02ED60s U02ED62As U02ED62ABs U02ED62Bs U02ED62AAs<br />

240 U03ED60 U03ED62As U03ED62ABs U03ED62Bs U03ED62AAs<br />

277 U16ED60s U16ED64As U16ED64ABs U16ED64Bs —<br />

480 U06ED60s U06ED64As U06ED64ABs U06ED64Bs —<br />

600 U08ED60s — — — —<br />

024 U13ED60 U13ED62As U13ED62ABs U13ED62Bs U13ED62AAs<br />

048 U14ED60s U14ED62As U14ED62ABs U14ED62Bs U14ED62AAs<br />

125 U10ED60s U10ED62As U10ED62ABs U10ED62Bs U10ED62AAs<br />

250 U12ED60s U12ED62As — — U12ED62AAs<br />

Auxiliary Switch Combinations<br />

Maximum 1 Alarm Switch and 1 Alarm Switch and<br />

Voltage 1 Auxiliary Switch 1 Auxiliary Switch 2 Auxiliary Switches 2 Auxiliary Switches<br />

AC DC Catalog Number Catalog Number Catalog Number Catalog Number<br />

240 250 A01ED62 A01ED62B A02ED62 A02ED62B<br />

480 A01ED64 A01ED64B — —<br />

Maximum<br />

Voltage 1 Auxiliary Switch<br />

AC DC Catalog Number<br />

24 A01EDLV Gold Plated Contacts—for PLC use<br />

Alarm Switch Only<br />

Maximum<br />

Voltage 1 Alarm Switch<br />

AC DC Catalog Number<br />

240 250 B00ED62<br />

480 B00ED64<br />

Ground Fault Sensing Relay Kit — Equipment Protection Only<br />

For Use With Number of Catalog Number<br />

Breaker Frame Poles Description 30mA 5mA<br />

Basic Kit GF01ED60 GF01ED65<br />

CED6, ED2, ED4<br />

Basic Kit with Normally<br />

ED6, EFC, EFF, 1, 2, 3 Open Bell Alarm<br />

GF01ED60B0 GF01ED65B0s<br />

Closed Bell Alarm<br />

HED4, HHED6<br />

Basic Kit with Normally<br />

GF01ED60BC GF01ED65BCs<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-113


Molded Case Circuit Breakers<br />

FD 250A Frame Sentron Series<br />

Revised on 05/31/18<br />

Selection<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Type FXD6-A a<br />

Blue Label<br />

Non-Interchangeable Trip (Assembled Circuit Breaker – Without Lugs)<br />

Continuous<br />

Current Rating<br />

2-Pole<br />

3-Pole<br />

@ 40°C<br />

Catalog Number<br />

Catalog Number<br />

70 FXD62B070n FXD63B070<br />

80 FXD62B080n FXD63B080<br />

90 FXD62B090n FXD63B090<br />

100 FXD62B100 FXD63B100<br />

110 FXD62B110n FXD63B110<br />

125 FXD62B125 FXD63B125<br />

150 FXD62B150 FXD63B150<br />

175 FXD62B175 FXD63B175<br />

200 FXD62B200 FXD63B200<br />

225 FXD62B225 FXD63B225<br />

250 FXD62B250 FXD63B250<br />

Type FD6-A <br />

Interchangeable Trip<br />

Continuous<br />

Current Rating<br />

@ 40°C<br />

Interrupting Ratings<br />

RMS Symmetrical Amperes (KA)<br />

UL 489 AIR (File E10848)<br />

IEC 947-2 g<br />

Volts AC (50/60Hz) Volts DC Volts AC (50/60Hz)<br />

Breaker<br />

240 480 600 250 500 c 220/240 380/415 500<br />

Type lcu lcs lcu lcs lcu lcs<br />

FXD6-A, FD6-A 65 35 22 30 (2-P) 18 (3-P) 65 33 35 18 — —<br />

HFXD6, HFD6 100 65 25 30 (2-P) 25 (3-P) 100 50 65 33 — —<br />

HHFD6, HHFXD6 200 100 25 — — — — — — — —<br />

CFD6 200 200 100 30 (2-P) 50 (3-P) — — — — — —<br />

Instantaneous Adjustment Trip Range<br />

Nominal Instantaneous Values<br />

+20% +20%<br />

Breaker Ampere Tolerance<br />

Tolerance<br />

Rating Low 2 3 4 5 6 7 High<br />

170-90 600 640 690 730 770 810 850 900<br />

100-110 700 770 840 920 990 1060 1140 1200<br />

125-150 800 900 1000 1100 1200 1300 1400 1500<br />

175-200 900 1060 1210 1370 1520 1780 1930 2000<br />

225-250 1100 1300 1500 1700 1900 2100 2300 2500<br />

Note: FD frame qualified to UL489 supplement SB “NAVAL”.<br />

See page 7-156 for additional information.<br />

Blue Label<br />

Complete Breaker<br />

Unassembled w/Lugs Frame Only Trip Unit Only<br />

Catalog Number Catalog Number Catalog Number<br />

2-Pole 600V AC, 250V DC b<br />

70 FD62B070n FD62T070n<br />

80 FD62B080n FD62T080n<br />

90 FD62B090n FD62T090n<br />

100 FD62B100n FD62T100n<br />

110 FD62B110n FD62T110n<br />

125 FD62B125n FD62F250 FD62T125n<br />

150 FD62B150 FD62T150<br />

175 FD62B175n FD62T175n<br />

200 FD62B200 FD62T200<br />

225 FD62B225n FD62T225n<br />

250 FD62B250n FD62T250n<br />

3-Pole 600V AC, 500V DC c<br />

70 FD63B070n FD63T070n<br />

80 FD63B080n FD63T080n<br />

90 FD63B090n FD63T090n<br />

100 FD63B100 FD63T100<br />

110 FD63B110n FD63T110n<br />

125 FD63B125 FD63F250 FD63T125<br />

150 FD63B150 FD63T150<br />

175 FD63B175 FD63T175<br />

200 FD63B200 FD63T200<br />

225 FD63B225 FD63T225<br />

250 FD63B250 FD63T250<br />

Ordering Information<br />

Complete Breaker Unassembled<br />

with Lugs<br />

Prices of FD6, HFD6, and HHFD6<br />

breakers includes frame, trip and<br />

both line and load lugs (TA1FD350A).<br />

When ordered by these catalog<br />

numbers, the customer will receive<br />

the frame, trip, and lugs separately<br />

packaged. For applications requiring<br />

different lugs, order individual items<br />

as needed.<br />

Complete Breaker Assembled without<br />

Lugs<br />

Prices of FXD6, HFXD6, HHFXD6,<br />

and CFD6 includes frame with<br />

non-interchangeable trip unit<br />

installed only. Order required lugs<br />

separately. For line and load lugs<br />

(TA1FD350A) installed, add suffix<br />

“L” to catalog number (add 2 times<br />

list price of lugs for each pole).<br />

50°C Applications see page 7-156.<br />

400 Hz Applications see page 7-156.<br />

Lugs For 75°C Wire e<br />

Catalog<br />

Wire<br />

Number Range<br />

TA1FD350A<br />

#6—350 kcmil Cu<br />

#4—350 kcmil Al<br />

TC1FD350 #6—350 kcmil Cu<br />

Compression Lug<br />

CCF250<br />

350 kcmil Cu/Al<br />

Enclosures<br />

Catalog<br />

Type<br />

Number<br />

1 F6N1S(F)<br />

3R<br />

F6N3R<br />

4-4X FD6SS4<br />

7-9 EC2<br />

12 F6N12<br />

Neutral d N250<br />

Modifications page 7-156<br />

Enclosures Section 6<br />

Accessories pages 7-116 and 7-160 to 7-165<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

a Type FXD6-A circuit breakers are UL Listed for reverse<br />

fed applications.<br />

b 2-pole units are 3-pole width.<br />

c When wired as shown on page 7-4, this circuit breaker is<br />

UL listed and rated for use on 500V DC ungrounded UPS<br />

systems only.<br />

d Order neutral as separate item.<br />

e See Note: A, page 7-153.<br />

f HACR rated.<br />

g Only applicable to interchangable trip unit types:<br />

FXD6A, HFXD6A.<br />

7-114<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

FD 250A Frame Sentron Series<br />

Selection/Dimensions<br />

Type HFD6, Type HFXD6 bc<br />

Interchangeable Trip<br />

Continuous<br />

Current Rating<br />

@ 40°C<br />

Type CFD6-A c<br />

Fuseless Current Limiting<br />

Red Label<br />

Non-Interchangeable Trip (Assembled Circuit Breaker<br />

without Lugs)<br />

Continuous<br />

Current Rating<br />

@ 40°C<br />

3-Pole<br />

600V AC/500V DC<br />

Catalog Number<br />

070 CFD63B070n<br />

080 CFD63B080n<br />

090 CFD63B090n<br />

100 CFD63B100n<br />

110 CFD63B110n<br />

125 CFD63B125n<br />

150 CFD63B150<br />

175 CFD63B175<br />

200 CFD63B200<br />

225 CFD63B225<br />

250 CFD63B250<br />

Black Label<br />

Complete Breaker<br />

Unassembled w/Lugs Frame Only Trip Unit Only<br />

Catalog Number Catalog Number Catalog Number<br />

2-Pole 600V AC, 250V DC (3-Pole Width)<br />

70 HFD62B070n FD62T070n<br />

80 HFD62B080n FD62T080n<br />

90 HFD62B090n FD62T090n<br />

100 HFD62B100n FD62T100n<br />

110 HFD62B110n FD62T110n<br />

125 HFD62B125n HFD62F250 FD62T125n<br />

150 HFD62B150n FD62T150n<br />

175 HFD62B175n FD62T175n<br />

200 HFD62B200n FD62T200n<br />

225 HFD62B225n FD62T225n<br />

250 HFD62B250n FD62T250n<br />

3-Pole 600V AC, 500V DC <br />

70 HFD63B070n FD63T070n<br />

80 HFD63B080n FD63T080n<br />

90 HFD63B090n FD63T090n<br />

100 HFD63B100 FD63T100<br />

110 HFD63B110n FD63T110n<br />

125 HFD63B125 HFD63F250 FD63T125<br />

150 HFD63B150 FD63T150<br />

175 HFD63B175 FD63T175<br />

200 HFD63B200 FD63T200<br />

225 HFD63B225 FD63T225<br />

250 HFD63B250 FD63T250<br />

Type HHFD, HHFXD6 bc<br />

3-Pole 600V AC, Extra High Interrupting<br />

70 HHFD63B070n FD63T070n<br />

80 HHFD63B080n FD63T080n<br />

90 HHFD63B090n FD63T090n<br />

100 HHFD63B100 FD63T100<br />

110 HHFD63B110n FD63T110n<br />

125 HHFD63B125 HHFD63F250 FD63T125<br />

150 HHFD63B150 FD63T150<br />

175 HHFD63B175 FD63T175<br />

200 HHFD63B200 FD63T200<br />

225 HHFD63B225 FD63T225<br />

250 HHFD63B250 FD63T250<br />

W <br />

Figure 1 Figure 2<br />

Dimensions (in inches)<br />

Breaker<br />

D1<br />

Type W L D (to<br />

handle)<br />

Figure 1<br />

FXD6-A, FD6-A,<br />

HFD6, HFXD6, 4.50 09.50 4 5.25<br />

HHFD6, FD6-ETI <br />

Figure 2<br />

CFD6,<br />

CFD6-ETI 4.50 14.25 4 5.25<br />

Shipping Weights<br />

Number of Number per Shipping<br />

Poles Carton Weight (lbs.)<br />

FD6-A, HFD6, HHFD6, FXD6-A<br />

Assembled Circuit Breaker (less connectors)<br />

2 1 08.6<br />

3 1 10<br />

FD6-A, HFD6, HHFD6 Frame Only<br />

2 1 07.5<br />

3 1 08.7<br />

FD6 Trip Unit Only<br />

2 1 01.1<br />

3 1 01.3<br />

CFD6 Assembled Circuit Breaker (less terminals)<br />

3 1 16<br />

D<br />

<br />

L<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

a When wired as shown on page 7-4, this circuit breaker<br />

is UL listed and rated for use on 500V DC ungrounded<br />

UPS systems.<br />

b For non-interchangeable trip 3-pole HFD6 type circuit<br />

breaker, change prefix identifier from HFD6 to HFXD6.<br />

Price equals frame and trip prices combined, e.g. price<br />

of HFXD63B250 equals price of HFD63F250 plus price of<br />

FD63T250. Order lugs separately.<br />

c Type HFXD6, HHFXD6, CFD6 are UL Listed for reverse<br />

feed applications.<br />

d FXD6, ETI, CFD6, ETI — See page 7-140 for<br />

ordering information.<br />

HACR rated.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-115


Molded Case Circuit Breakers<br />

Internal Accessories<br />

Revised on 08/31/20<br />

Selection<br />

Accessories:<br />

for FD, FFC & FFF 250A Frames<br />

Shunt Trip Combinations<br />

Control Voltage 1 Shunt Trip<br />

AC DC Catalog Number<br />

024 S17FD60<br />

120 S01FD60<br />

240 S03FD60<br />

277 S15FD60s<br />

480 S04FD60<br />

600 S06FD60s<br />

012 S16FD60s<br />

024 S07FD60<br />

048 S09FD60s<br />

125 S11FD60<br />

250 S13FD60s<br />

Undervoltage Trip Combinations<br />

Control Voltage<br />

1 Undervoltage Trip<br />

1 Undervoltage Trip and<br />

1 Auxiliary Switch<br />

S01FD60<br />

AC DC Catalog Number Catalog Number<br />

120 U01FD60 W01FD64<br />

208 U02FD60s W02FD64s<br />

240 U03FD60 W03FD64s<br />

277 U16FD60s W16FD64s<br />

480 U06FD60s W06FD64s<br />

024 U13FD60 W13FD64<br />

048 U14FD60s W14FD64s<br />

125 U10FD60s W10FD64s<br />

Auxiliary Switch Combinations<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Voltage 1 Auxiliary Switch 2 Auxiliary Switches<br />

AC DC Catalog Number Catalog Number<br />

240 A01FD62 A02FD62<br />

480 A01FD64 A02FD64<br />

24 A01FDLV Gold Plated Contacts -<br />

for PLC use<br />

Alarm Switch Combinations<br />

Maximum<br />

Voltage<br />

1 Alarm Switch<br />

1 Alarm Switch and<br />

1 Auxiliary Switch<br />

AC DC Catalog Number Catalog Number<br />

480 250 B00FD64 C01FD64<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

aAuxiliary switch application is for 480V AC maximum.<br />

Note: Old F-frame accessories cannot be used in new<br />

Sentron line. Likewise, new FD-frame accessories<br />

cannot be used on old F-frame circuit breakers.<br />

7-116<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

JD 400A Frame Sentron Series<br />

Revised on 05/31/18<br />

Selection<br />

Type JXD2-A <br />

240V AC, 2-Pole 250V DC Only<br />

Blue Label<br />

Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs)<br />

Continuous Current<br />

Rating @ 40°C<br />

2-Pole (3-Pole Width)<br />

Catalog Number<br />

3-Pole<br />

Catalog Number<br />

200 JXD22B200n JXD23B200<br />

225 JXD22B225n JXD23B225<br />

250 JXD22B250n JXD23B250<br />

300 JXD22B300 JXD23B300<br />

350 JXD22B350n JXD23B350<br />

400 JXD22B400 JXD23B400<br />

Type JXD6-A a<br />

600V AC, 2-Pole 250V DC, 3-Pole 500V DC b<br />

Blue Label<br />

Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs)<br />

200 JXD62B200n JXD63B200<br />

225 JXD62B225n JXD63B225<br />

250 JXD62B250n JXD63B250<br />

300 JXD62B300 JXD63B300<br />

350 JXD62B350n JXD63B350<br />

400 JXD62B400 JXD63B400<br />

Type JD6-A <br />

Interchangeable Trip<br />

Continuous<br />

Current Rating<br />

@ 40°C<br />

Interrupting Ratings<br />

RMS Symmetrical Amperes (KA)<br />

UL 489 AIR (File E10848)<br />

IEC 947-2 e<br />

Volts AC Volts DC Volts AC (50/60Hz)<br />

Breaker<br />

(50/60Hz) 220/240 380/415 500<br />

Type 240 480 600 250 500 b lcu lcs lcu lcs lcu lcs<br />

JXD2-A 065 — — 30 (2-P) — — — — — — —<br />

JXD6-A, JD6-A 065 035 025 30 (2-P) 25 (3-P) 065 033 040 20 — —<br />

HJD6-A, HJXD6-A 100 065 035 30 (2-P) 35 (3-P) 100 050 065 33 — —<br />

HHJD6, HHJXD6 200 100 050 — — — — — — — —<br />

CJD6-A 200 150 100 30 (2-P) 50 (3-P) — — — — — —<br />

Instantaneous Adjustment Trip Range<br />

Blue Label<br />

Complete Breaker<br />

Unassembled w/Lugs Frame Only Trip Unit Only<br />

Catalog Number Catalog Number Catalog Number<br />

2-Pole 600V AC, 250V DC (3-Pole Width)<br />

200 JD62B200n JD62T200n<br />

225 JD62B225n JD62T225n<br />

250 JD62B250n JD62F400 JD62T250n<br />

300 JD62B300n JD62T300n<br />

350 JD62B350n JD62T350n<br />

400 JD62B400 JD62T400<br />

3-Pole 600V AC, 500V DC b<br />

200 JD63B200 JD63T200<br />

225 JD63B225 JD63T225<br />

250 JD63B250 JD63F400 JD63T250<br />

300 JD63B300 JD63T300<br />

350 JD63B350 JD63T350<br />

400 JD63B400 JD63T400<br />

Nominal Instantaneous Values<br />

+20% +20%<br />

Breaker Ampere Tolerance Tolerance<br />

Rating Low 2 3 4 5 6 7 High<br />

200-300 1250 1430 1610 1790 1960 2140 2320 2500<br />

350-400 2000 2290 2570 2860 3140 3430 3710 4000<br />

Ordering Information<br />

Complete Breaker Unassembled<br />

with Lugs<br />

Prices of JD6, HJD6, and HHJD6<br />

breakers include frame, trip and<br />

both line and load lugs (TA2J6500).<br />

When ordered by these catalog<br />

numbers, the customer will receive<br />

the frame, trip, and lugs separately<br />

packaged. For applications<br />

requiring different lugs, order<br />

individual items as needed.<br />

Complete Breaker Assembled without<br />

Lugs<br />

Prices of JXD6, HJXD6, HHJXD6,<br />

and CJD6 include frame with<br />

non-interchangeable trip unit<br />

installed only. Order required lugs<br />

separately. For line and load lugs<br />

(TA2J6500) installed, add suffix “L”<br />

to catalog number (add 2 times list<br />

price of lugs for each pole).<br />

100% Rated (3-pole only)<br />

Types JXD6 and HJXD6 breakers<br />

are available with 100% ratings.<br />

To order add suffix “H” to catalog<br />

number, and 10% to list price.n<br />

100% rated JD breakers require the<br />

use of 90°C Cu cable sized at 75°C<br />

ampacity and lugs TC1J6600<br />

or TC2J6500.<br />

50°C Applications see page 7-156.<br />

400Hz Applications see page 7-156.<br />

Lugs For 75°C Wire c<br />

Cables<br />

Catalog per Wire<br />

Number Lug Range<br />

TA2J6500 1, 2 #3/0-500 kcmil Cu<br />

2 #4/0-500 kcmil Al<br />

TA1L6750 1 500-750 kcmil Al<br />

1 500-600 kcmil Cu<br />

TC1J6600 1 #3/0-600 kcmil Cu<br />

TC2J6500 1, 2 #3/0-500 kcmil Cu<br />

Compression Lug<br />

CCL600 1 500 kcmil Cu/Al<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

a Type JXD2 and JXD6 circuit breakers are UL Listed for<br />

reverse feed applications.<br />

bWhen wired as shown on page 7-4, this circuit breaker is<br />

UL listed and rated for use on 500V DC ungrounded UPS<br />

systems only.<br />

c See Note: A, page 7-153.<br />

d HACR rated.<br />

e Only applicable to interchangable trip unit types:<br />

JXD6-A, HJXD6-A.<br />

Note: JD frame qualified to UL489 supplement B<br />

“NAVAL.” See page 7-156 for additional information.<br />

Modifications page 7-156<br />

Enclosures Section 6<br />

Accessories pages 7-120 and 7-160 to 7-165<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-117


Molded Case Circuit Breakers<br />

JD 400A Frame Sentron Series<br />

Selection/Dimensions<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Type HJD6-A, HJXD6-A bdf<br />

Interchangeable Trip<br />

Continuous<br />

Current Rating<br />

@ 40°C<br />

Black Label<br />

Complete Breaker<br />

Unassembled w/Lugs Frame Only Trip Unit Only<br />

Catalog Number Catalog Number Catalog Number<br />

2-Pole 600V AC, 250V DC (3-Pole Width)<br />

200 HJD62B200n JD62T200n<br />

225 HJD62B225n JD62T225n<br />

250 HJD62B250n HJD62F400n JD62T250n<br />

300 HJD62B300n JD62T300n<br />

350 HJD62B350n JD62T350n<br />

400 HJD62B400n JD62T400<br />

3-Pole 600V AC, 500V DC abe<br />

200 HJD63B200 JD63T200<br />

225 HJD63B225 JD63T225<br />

250 HJD63B250 HJD63F400 JD63T250<br />

300 HJD63B300 JD63T300<br />

350 HJD63B350 JD63T350<br />

400 HJD63B400 JD63T400<br />

Type HHJD6, HHJXD6 bdf<br />

Black Label<br />

2-Pole 600V AC (3-Pole Width)<br />

200 HHJD62B200n JD62T200n<br />

225 HHJD62B225n JD62T225n<br />

250 HHJD62B250n HHJD62F400n JD62T250n<br />

300 HHJD62B300n JD62T300n<br />

350 HHJD62B350n JD62T350n<br />

400 HHJD62B400n JD62T400<br />

3-Pole 600VAC<br />

200 HHJD63B200 JD63T200<br />

225 HHJD63B225 JD63T225<br />

250 HHJD63B250 HHJD63F400 JD63T250<br />

300 HHJD63B300 JD63T300<br />

350 HHJD63B350 JD63T350<br />

400 HHJD63B400 JD63T400<br />

Type CJD6-A ef<br />

Fuseless Current Limiting<br />

Red Label<br />

Non-Interchangeable Trip (Assembled Circuit Breaker<br />

Without Lugs)<br />

Continuous<br />

Current Rating<br />

@ 40°C<br />

200<br />

2-Pole<br />

600V AC/250V DC<br />

Catalog Number<br />

3-Pole<br />

600V AC/500V DC<br />

Catalog Number<br />

CJD63B200n<br />

225 CJD63B225n<br />

250<br />

For 2-pole application<br />

CJD63B250n<br />

use outside poles of<br />

300<br />

3-pole circuit breaker<br />

CJD63B300n<br />

350 CJD63B350n<br />

400 CJD63B400<br />

<br />

D1<br />

W <br />

D<br />

Figure 1 Figure 2<br />

Dimensions (in inches)<br />

To<br />

Breaker<br />

Handle<br />

Type W L D D1<br />

Figure 1<br />

JXD2-A, JXD6-A, JD6-A<br />

HJD6-A, HJXD6-A, HHJD6, 7.5 11 4 5.44<br />

HJD6, HJXD6, HHJXD6,<br />

JXD6-ETI, c SJD6, SHJD6<br />

Figure 2<br />

CJD6, CJD6-ETI, c SCJD6<br />

7.5 17.86 4 5.44<br />

Enclosures (Except SCJD6)<br />

Type<br />

Catalog Number<br />

1 J6N1<br />

3R<br />

J6N3R<br />

12 J6N12<br />

4X<br />

LD6SS4<br />

7, 9 (200-250A) EC4<br />

7, 9 (300-400A) EE<br />

Neutral<br />

W60992<br />

Shipping Weights<br />

Number of Number per Shipping<br />

Poles Carton Weight (lbs.)<br />

JXD2, JXD6, JD6, HJD6, HHJD6<br />

Assembled Breaker (less terminals)<br />

2 1 17.5<br />

3 1 19.5<br />

JD6, HJD6, HHJD6 Frame Only<br />

2 1 14<br />

3 1 15.5<br />

JD6 Trip Unit Only<br />

2 1 03.5<br />

3 1 04<br />

CJD6 Complete Assembled Breaker<br />

(less terminals)<br />

3 1 31.5<br />

D<br />

For inches / millimeters conversion, see Application Data section.<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

2-pole units available in 3-pole construction.<br />

a When wired as shown on page 7-4, this circuit breaker is<br />

UL listed and rated for use on 500V DC ungrounded<br />

UPS systems only.<br />

b For non-interchangeable 3-pole HJD6 or HHJD6 type<br />

circuit breaker change the prefix identifier to HJXD6<br />

or HHJXD6. Price equals price of frame plus price of<br />

trip, e.g. price of HJXD63B400 equals price of<br />

HJD63F400 plus price of JD63T400. Order lugs<br />

separately.<br />

c JXD6-ETI, CJD6-ETI see page 7-140 for ordering information.<br />

d Type HJXD6, HHJXD6 Circuit Breakers are UL listed for<br />

reverse fed applications.<br />

e CE applies to non-interchangeable type HJXD6-A only.<br />

f HACR rated.<br />

7-118<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

SJD 400A Frame Digital Solid State Sentron Sensitrip IV Series<br />

Revised on 10/31/18<br />

Selection<br />

Current Limiting<br />

Type SJD6-B Type SHJD6-B Type SCJD6-B<br />

Blue Label Black Label Red Label<br />

Max 3-Pole, 600V AC 3-Pole, 600V AC 3-Pole, 600V AC<br />

Current<br />

Rating<br />

Catalog Number<br />

(Advanced trip unit) c<br />

Catalog Number<br />

(Basic trip unit)<br />

Catalog Number<br />

(Advanced trip unit) c<br />

Catalog Number<br />

(Basic trip unit)<br />

Catalog Number<br />

(Advanced trip unit) c<br />

Catalog Number<br />

(Basic trip unit)<br />

200 SJD6A200LI SJD6B200LI SHJD6A200LI SHJD6B200LI SCJD6A200LI SCJD6B200LI<br />

300 SJD6A300LI SJD6B300LI SHJD6A300LI SHJD6B300LI SCJD6A300LI SCJD6B300LI<br />

400 SJD6A400LI SJD6B400LI SHJD6A400LI SHJD6B400LI SCJD6A400LI SCJD6B400LI<br />

200 SJD6A200LIG SJD6B200LIG SHJD6A200LIG SHJD6B200LIG SCJD6A200LIG SCJD6B200LIG<br />

300 SJD6A300LIG SJD6B300LIG SHJD6A300LIG SHJD6B300LIG SCJD6A300LIG SCJD6B300LIG<br />

400 SJD6A400LIG SJD6B400LIG SHJD6A400LIG SHJD6B400LIG SCJD6A400LIG SCJD6B400LIG<br />

200 SJD6A200LSI SJD6B200LSI SHJD6A200LSI SHJD6B200LSI SCJD6A200LSI SCJD6B200LSI<br />

300 SJD6A300LSI SJD6B300LSI SHJD6A300LSI SHJD6B300LSI SCJD6A300LSI SCJD6B300LSI<br />

400 SJD6A400LSI SJD6B400LSI SHJD6A400LSI SHJD6B400LSI SCJD6A400LSI SCJD6B400LSI<br />

200 SJD6A200LSIG SJD6B200LSIG SHJD6A200LSIG SHJD6B200LSIG SCJD6A200LSIG SCJD6B200LSIG<br />

300 SJD6A300LSIG SJD6B300LSIG SHJD6A300LSIG SHJD6B300LSIG SCJD6A300LSIG SCJD6B300LSIG<br />

400 SJD6A400LSIG SJD6B400LSIG SHJD6A400LSIG SHJD6B400LSIG SCJD6A400LSIG SCJD6B400LSIG<br />

SJD 400A Frame – 100% Rated b<br />

Type SJD6-B<br />

Blue Label<br />

Type SHJD6-B<br />

Black Label<br />

Max 3-Pole, 600V AC<br />

3-Pole, 600V AC<br />

Current<br />

Rating<br />

Catalog Number<br />

(Advanced trip unit) c<br />

Catalog Number<br />

(Basic trip unit)<br />

Catalog Number<br />

(Advanced trip unit) c<br />

Catalog Number<br />

(Basic trip unit)<br />

200 SJD6A200LIH SJD6B200LIH SHJD6A200LIH SHJD6B200LIH<br />

300 SJD6A300LIH SJD6B300LIH SHJD6A300LIH SHJD6B300LIH<br />

400 SJD6A400LIH SJD6B400LIH SHJD6A400LIH SHJD6B400LIH<br />

200 SJD6A200LIGH SJD6B200LIGH SHJD6A200LIGH SHJD6B200LIGH<br />

300 SJD6A300LIGH SJD6B300LIGH SHJD6A300LIGH SHJD6B300LIGH<br />

400 SJD6A400LIGH SJD6B400LIGH SHJD6A400LIGH SHJD6B400LIGH<br />

200 SJD6A200LSIH SJD6B200LSIH SHJD6A200LSIH SHJD6B200LSIH<br />

300 SJD6A300LSIH SJD6B300LSIH SHJD6A300LSIH SHJD6B300LSIH<br />

400 SJD6A400LSIH SJD6B400LSIH SHJD6A400LSIH SHJD6B400LSIH<br />

200 SJD6A200LSIGH SJD6B200LSIGH SHJD6A200LSIGH SHJD6B200LSIGH<br />

300 SJD6A300LSIGH SJD6B300LSIGH SHJD6A300LSIGH SHJD6B300LSIGH<br />

400 SJD6A400LSIGH SJD6B400LSIGH SHJD6A400LSIGH SHJD6B400LSIGH<br />

Trip Unit Adjustable Functions<br />

No. of<br />

cables<br />

per connector<br />

Suffix<br />

Letter<br />

Code<br />

Trip<br />

Type<br />

Cont<br />

Current<br />

Setting<br />

Long<br />

Time<br />

Delay<br />

Instantaneous<br />

Pick Up<br />

LI LI u u u<br />

Short<br />

Time<br />

Pick Up<br />

Short<br />

Time<br />

Fixed<br />

Delay<br />

Short<br />

Time<br />

l 2 t<br />

Delay<br />

Ground<br />

Fault<br />

Pick Up<br />

LIG LIG u u u u u<br />

LSI LSI u u u u u u<br />

LSIG LSIG u u u u u u u u<br />

Interrupting Ratings<br />

Breaker<br />

Type<br />

RMS Symmetrical kA<br />

UL 489 (File E10848)<br />

240V AC 480V AC 600V AC<br />

SJD6-B 65 35 25<br />

SHJD6-B 100 65 35<br />

SCJD6-B 200 150 100<br />

Neutral Transformers<br />

Ampere Rating Catalog Number<br />

200 N02SJD<br />

300 N03SJD<br />

400 N04SJD<br />

Ground<br />

Fault<br />

Delay<br />

Ordering Information<br />

Pricing information for all Digital<br />

Sentron Series SJD Frames is<br />

for complete breaker only - price<br />

required lugs as separate items -<br />

lugs are suitable for 75°C Wire.<br />

SJD6-B, SHJD6-B and SCJD6-B are<br />

acceptable for reverse connection<br />

application.<br />

Shipping Weights<br />

Breaker<br />

Type<br />

Number per<br />

Carton<br />

SJD6-B 1 20<br />

SHJD6-B 1 20<br />

SCJD6-B 1 33<br />

Lugs for 75° C Wire a<br />

Catalog<br />

Number<br />

Wire<br />

Range<br />

Shipping<br />

Weight (lbs)<br />

2 #3/0-500 kcmil Cu<br />

TA2J6500<br />

2 #4/0-500 kcmil Al<br />

1 500-750 kcmil Al<br />

TA1L6750<br />

1 500-600 kcmil Cu<br />

TC1J6600 1 #3/0-600 kcmil Cu<br />

TC2J6500 2 #3/0-500 kcmil Cu<br />

TA2J630 2 #4-#3/0 Cu/Al<br />

Compression Lug<br />

CCL600 1 (pc.) #1/0-500 kcmil Cu/Al<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Note: “G” suffix in catalog number denotes circuit<br />

breaker for 3-phase, 3-wire systems.<br />

For 3-phase, 4-wire, order correct 4th wire (neutral)<br />

transformer as separate and additional item.<br />

All breakers built to order. Allow 2–3 weeks for delivery.<br />

aFor additional information, see Note: A, page 7-153.<br />

b Refer to the NEC for proper application of 100%<br />

rated devices.<br />

c Advanced trip unit equipped with DAS /<br />

Maintenance Mode. Requires customer-supplied 24V<br />

external power supply, maintenance switch and light.<br />

Enclosures Section 6<br />

Accessories pages 7-120 and 7-160 to 7-165<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-119


Molded Case Circuit Breakers<br />

Internal Accessories<br />

Revised on 08/31/20<br />

Selection<br />

Accessories for:<br />

JD 400A Frame<br />

LD 600A Frame<br />

LMD 800A Frame<br />

SJD 400A Frame<br />

SLD 600A Frame<br />

Shunt Trip Combinations<br />

Control Voltage 1 Shunt Trip<br />

1 Shunt Trip and<br />

1 Auxiliary Switch<br />

AC DC Catalog Number Catalog Number<br />

024 S17JLD6 —<br />

048 S18JLD6s —<br />

120 S01JLD6 S01JLD62A<br />

240 S03JLD6 S03JLD62A<br />

277 S15JLD6s S15JLD64As<br />

480 S04JLD6 —<br />

012 S16JLD6s S16JLD62As<br />

024 S07JLD6 S07JLD62A<br />

048 S09JLD6s S09JLD62A<br />

125 S11JLD6 S11JLD62As<br />

250 S13JLD6s S13JLD62As<br />

Undervoltage Trip Combinations<br />

Control Voltage<br />

1 Undervoltage Trip<br />

1 Undervoltage Trip and<br />

1 Auxiliary Switch<br />

1 Undervoltage Trip and<br />

2 Auxiliary Switches<br />

S01JLD6<br />

AC DC Catalog Number Catalog Number Catalog Number<br />

120 U01JLD6 U01JLD62A U01JLD62AA<br />

208 U02JLD6s U02JLD62As U02JLD62AAs<br />

240 U03JLD6 U03JLD62As U03JLD62AAs<br />

480 U06JLD6 U06JLD64As U06JLD64AAs<br />

024 U13JLD6 U13JLD62A U13JLD62AA<br />

048 U14JLD6s U14JLD62As U14JLD62AAs<br />

125 U10JLD6s U10JLD62As U10JLD62AAs<br />

Auxiliary Switch Combinations<br />

Maximum<br />

Voltage 1 Form C 2 Form C<br />

AC DC Catalog Number Catalog Number<br />

480 250 A01JLD64 A02JLD64<br />

— 24 A01JLDLV A02JLDLV<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Alarm Switch Combinations<br />

Maximum<br />

Voltage<br />

1 Alarm Switch<br />

1 Alarm Switch and<br />

1 Auxiliary Switch<br />

1 Alarm Switch and<br />

2 Auxiliary Switches<br />

AC DC Catalog Number Catalog Number CatalogNumber<br />

480 250 B01JLD64 A01JLD64B A02JLD64B<br />

ETU Testing Unit<br />

Breaker Type Description Catalog Number<br />

SJD, SLD, SMD, Power Stick<br />

EPSP18V<br />

SND, SPD<br />

Spare cable for Power Stick COMPCA<br />

The EPSP18V Power Stick is a hand-held, battery-operated power supply<br />

that can be used for trip testing the Sensitrip IV electronic trip units.<br />

Requires two 9V batteries.<br />

Note: Accessory modules can only be added to right<br />

side pole of solid state SJD and SLD frame circuit<br />

breakers. No accessories can be added if<br />

mechanical interlock is used. All accessories on this<br />

page are useable on superseded JD2, JJ6, JL6, HJ6,<br />

SJL, LJ6, LL6, HL6 and SLL circuit breakers.<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

7-120<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

LD 600A Frame Sentron Series<br />

Revised on 05/31/18<br />

Selection<br />

Type LXD6-A ad<br />

Blue Label<br />

Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs)<br />

2-Pole (3-Pole Width) 3-Pole<br />

Continuous<br />

Current Rating<br />

600V AC 250V DC 600V AC 500V DC<br />

@ 40°C<br />

Catalog Number<br />

Catalog Number<br />

450 LXD62B450n LXD63B450<br />

500 LXD62B500n LXD63B500<br />

600 LXD62B600 LXD63B600<br />

Type LD6-A d<br />

Interchangeable Trip<br />

Continuous<br />

Current Rating<br />

@ 40°C<br />

Interrupting Ratings<br />

RMS Symmetrical Amperes (KA)<br />

UL 489 AIR (File E10848)<br />

IEC 947-2 e<br />

Breaker<br />

Volts AC (50/60Hz) Volts DC Volts AC (50/60Hz)<br />

Type 240 480 600 250 500 c 220/240 380/415 500<br />

(lcu) (lcs) (lcu) (lcs) (lcu) (lcs)<br />

LD6-A, LXD6-A 065 035 025 30 (2-P) 25 (3-P) 065 033 040 20 — —<br />

HLD6-A, HLXD6-A 100 065 035 30 (2-P) 35 (3-P) 100 050 065 33 — —<br />

HHLD6, HHLXD6 200 100 050 — — — — — — — —<br />

CLD6-A 200 150 100 — 50 (3-P) — — — — — —<br />

Instantaneous Adjustment Trip Range<br />

Nominal Instantaneous Values<br />

+20% +20%<br />

Breaker Ampere Tolerance Tolerance<br />

Rating Low 2 3 4 5 6 7 High<br />

250-300 1250 1430 1610 1790 1960 2140 2320 2500<br />

350-450 2000 2290 2570 2860 3140 3430 3710 4000<br />

500-600 3000 3430 3800 4290 4710 5140 5570 6000<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

a Type LXD6A circuit breakers are UL Listed for reverse<br />

fed applications.<br />

b When wired as shown on page 7-4, this circuit breaker is<br />

UL listed and rated for use on 500V DC ungrounded<br />

UPS systems only.<br />

c See Note: A, page 7-153.<br />

d HACR rated.<br />

e Only applicable to interchangable trip unit types:<br />

LXD6, HLXD6.<br />

Note: LD frame qualified to UL489 supplement SB “NAVAL”.<br />

See page 7-156 for additional information.<br />

Blue Label<br />

Complete Breaker<br />

Unassembled w/Lugs Frame Only Trip Unit Only<br />

Catalog Number Catalog Number Catalog Number<br />

2-Pole 600V AC, 250V DC (3-Pole Width)<br />

250 LD62B250n JD62T250n<br />

300 LD62B300n JD62T300n<br />

350 LD62B350n JD62T350n<br />

400 LD62B400 LD62F600 JD62T400<br />

450 LD62B450n LD62T450n<br />

500 LD62B500n LD62T500n<br />

600 LD62B600 LD62T600<br />

3-Pole 600V AC, 500V DC b<br />

250 LD63B250 JD63T250<br />

300 LD63B300 JD63T300<br />

350 LD63B350 JD63T350<br />

400 LD63B400 LD63F600 JD63T400<br />

450 LD63B450 LD63T450<br />

500 LD63B500 LD63T500<br />

600 LD63B600 LD63T600<br />

Modifications page 7-156<br />

Enclosures Section 6<br />

Accessories pages 7-124 and 7-160 to 7-165<br />

Ordering Information<br />

Complete Breaker Unassembled<br />

with Lugs<br />

Prices of LD6, HLD6, and HHLD6<br />

breakers include frame, trip, and<br />

both line and load lugs (TA2J6500).<br />

When ordered by these catalog<br />

numbers, the customer will receive<br />

the frame, trip and lugs separately<br />

packaged. For applications requiring<br />

different lugs, order individual items<br />

as needed.<br />

Complete Breaker Assembled without<br />

Lugs<br />

Prices of LXD6, HLXD6, HHLXD6,<br />

and CLD6 include frame with noninterchangeable<br />

trip unit installed<br />

only. Order required lugs separately.<br />

For line and load lugs (TA2J6500)<br />

installed, add suffix “L” to catalog<br />

number (add 2 times list price of<br />

lugs for each pole).<br />

100% Rated (3-pole only)<br />

Types LXD6 and HLXD6 breakers<br />

are available with 100% ratings.<br />

To order add suffix “H” to catalog<br />

number, and 10% to list price. 100%<br />

rated LD breakers require the use of<br />

90°C Cu cable sized at 75°C<br />

ampacity and lugs TC1J6600<br />

or TC2J6500.<br />

50°C Applications see page 7-156.<br />

400Hz Applications see page 7-156.<br />

Shipping Weights<br />

Number of Number per Shipping<br />

Poles Carton Weight (lbs.)<br />

LXD6, LD6, HLD6, HHLD6<br />

Assembled Breaker (less terminals)<br />

2 1 17.5<br />

3 1 19.5<br />

LD6, HLD6, HHLD6 Frame Only<br />

2 1 14<br />

3 1 15.5<br />

LD6, HHLD6 Trip Unit Only<br />

2 1 03.5<br />

3 1 04<br />

CLD6 Complete Assembled Breaker<br />

(less terminals)<br />

3 1 31.5<br />

Lugs For 75°C Wire c<br />

Cables<br />

Catalog per Wire<br />

Number Lug Range<br />

TA2J6500 1, 2 #3/0 500 kcmil Cu<br />

2 #4/0 500 kcmil Al<br />

TC2J6500 2 #3/0-500 kcmil Cu<br />

TA1L6750 1 500-750 kcmil Al<br />

1 500-600 kcmil Cu<br />

TC1J6600 1 #3/0-600 kcmil Cu<br />

Compression Lug<br />

CCL600 1 500 kcmil Cu/Al<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-121


Molded Case Circuit Breakers<br />

LD 600A Frame Sentron Series<br />

Selection/Dimensions<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Type HLD6-A, HLXD6-A bcf<br />

Interchangeable Trip<br />

Continuous<br />

Current Rating<br />

@ 40°C<br />

Black Label<br />

Complete Breaker<br />

Unassembled w/Lugs Frame Only Trip Unit Only<br />

Catalog Number Catalog Number Catalog Number<br />

2-Pole 600V AC, 250V DC (3-Pole Width)<br />

250 HLD62B250n JD62T250n<br />

300 HLD62B300n JD62T300n<br />

350 HLD62B350n JD62T350n<br />

400 HLD62B400n HLD62F600n JD62T400<br />

450 HLD62B450n LD62T450n<br />

500 HLD62B500n LD62T500n<br />

600 HLD62B600n LD62T600<br />

3-Pole 600V AC, 500V DC ae<br />

250 HLD63B250 JD63T250<br />

300 HLD63B300 JD63T300<br />

350 HLD63B350 JD63T350<br />

400 HLD63B400 HLD63F600 JD63T400<br />

450 HLD63B450 LD63T450<br />

500 HLD63B500 LD63T500<br />

600 HLD63B600 LD63T600<br />

Type HHLD6, HHLXD6 bcf<br />

Black Label<br />

2-Pole 600V AC (3-Pole Width)<br />

250 HHLD62B250n JD62T250n<br />

300 HHLD62B300n JD62T300n<br />

350 HHLD62B350n JD62T350n<br />

400 HHLD62B400n HHLD62F600n JD62T400<br />

450 HHLD62B450n HHLD62T450n<br />

500 HHLD62B500n HHLD62T500n<br />

600 HHLD62B600n HHLD62T600n<br />

3-Pole 600V AC<br />

250 HHLD63B250 JD63T250<br />

300 HHLD63B300 JD63T300<br />

350 HHLD63B350 JD63T350<br />

400 HHLD63B400 HHLD63F600 JD63T400<br />

450 HHLD63B450n HHLD63T450n<br />

500 HHLD63B500n HHLD63T500n<br />

600 HHLD63B600n HHLD63T600n<br />

Type CLD6-A cf<br />

Fuseless Current Limiting<br />

Red Label<br />

Non-Interchangeable Trip (Assembled Circuit Breaker<br />

Without Lugs)<br />

Continuous<br />

Current Rating<br />

@ 40°C<br />

2-Pole<br />

600V AC/250V DC<br />

Catalog Number<br />

3-Pole<br />

600V AC/500V DC<br />

Catalog Number<br />

CLD63B450n<br />

450 For 2-pole application<br />

500 use outside poles of CLD63B500<br />

600 3-pole circuit breaker CLD63B600<br />

<br />

D1<br />

D<br />

Figure 1 Figure 2<br />

Dimensions (in inches)<br />

L<br />

To<br />

Handle<br />

Breaker<br />

Type W L D D1<br />

Figure 1<br />

LXD6-A, LD6-A<br />

HLD6-A<br />

HHLD6, HHLXD6,<br />

7.5 11 4 5.44<br />

LXD6–ETI, d SLD6, SHLD6<br />

Figure 2<br />

CLD6, 7.5 17.86 4 5.44<br />

CLD6-ETI, d SCLD6<br />

D<br />

Enclosures: (except SCLD6)<br />

Type<br />

Catalog Number<br />

1 LD6N1<br />

3R<br />

LD6N3R<br />

12 LD6N12<br />

4X<br />

LD6SS4<br />

7,9 ED6<br />

Neutral<br />

W60993<br />

L<br />

For inches / millimeters conversion, see Application Data section.<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

a When wired as shown on page 7-4, this circuit breaker is<br />

UL listed and rated for use on 500V DC ungrounded<br />

UPS systems only.<br />

b For complete assembled 3-pole HLD6 or HHLD6 type<br />

circuit breaker change the prefix identifier HLD6 or<br />

HHLD6 to HLXD6 or HHLXD6. Price is sum of frame and<br />

trip units prices, e.g. price of HLXD63B400 is the price of<br />

HLD63F600 plus the price of LD63T600. Order the<br />

terminal connectors separately.<br />

c Type HLXD6, HHLXD6, & CLD6 Circuit Breakers are UL<br />

Listed for reverse feed applications.<br />

d LXD6-ETI, CLD6-ETI see page 7-140 for ordering information.<br />

e CE Applies to non-interchangeable type HLXD only.<br />

f HACR rated.<br />

7-122<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

SLD 600A Frame Digital Solid State Sentron Sensitrip IV Series<br />

Revised on 10/31/18<br />

Selection<br />

Current Limiting<br />

Type SLD6-B Type SHLD6-B Type SCLD6-B<br />

Blue Label Black Label Red Label<br />

Max 3-Pole, 600V AC 3-Pole, 600V AC 3-Pole, 600V AC<br />

Current<br />

Rating<br />

Catalog Number<br />

(Advanced trip unit) a<br />

Catalog Number<br />

(Basic trip unit)<br />

Catalog Number<br />

(Advanced trip unit) a<br />

Catalog Number<br />

(Basic trip unit)<br />

Catalog Number<br />

(Advanced trip unit) a<br />

Catalog Number<br />

(Basic trip unit)<br />

300 SLD6A300LI SLD6B300LI SHLD6A300LI SHLD6B300LI SCLD6A300LI SCLD6B300LI<br />

400 SLD6A400LI SLD6B400LI SHLD6A400LI SHLD6B400LI SCLD6A400LI SCLD6B400LI<br />

500 SLD6A500LI SLD6B500LI SHLD6A500LI SHLD6B500LI SCLD6A500LI SCLD6B500LI<br />

600 SLD6A600LI SLD6B600LI SHLD6A600LI SHLD6B600LI SCLD6A600LI SCLD6B600LI<br />

300 SLD6A300LIG SLD6B300LIG SHLD6A300LIG SHLD6B300LIG SCLD6A300LIG SCLD6B300LIG<br />

400 SLD6A400LIG SLD6B400LIG SHLD6A400LIG SHLD6B400LIG SCLD6A400LIG SCLD6B400LIG<br />

500 SLD6A500LIG SLD6B500LIG SHLD6A500LIG SHLD6B500LIG SCLD6A500LIG SCLD6B500LIG<br />

600 SLD6A600LIG SLD6B600LIG SHLD6A600LIG SHLD6B600LIG SCLD6A600LIG SCLD6B600LIG<br />

300 SLD6A300LSI SLD6B300LSI SHLD6A300LSI SHLD6B300LSI SCLD6A300LSI SCLD6B300LSI<br />

400 SLD6A400LSI SLD6B400LSI SHLD6A400LSI SHLD6B400LSI SCLD6A400LSI SCLD6B400LSI<br />

500 SLD6A500LSI SLD6B500LSI SHLD6A500LSI SHLD6B500LSI SCLD6A500LSI SCLD6B500LSI<br />

600 SLD6A600LSI SLD6B600LSI SHLD6A600LSI SHLD6B600LSI SCLD6A600LSI SCLD6B600LSI<br />

300 SLD6A300LSIG SLD6B300LSIG SHLD6A300LSIG SHLD6B300LSIG SCLD6A300LSIG SCLD6B300LSIG<br />

400 SLD6A400LSIG SLD6B400LSIG SHLD6A400LSIG SHLD6B400LSIG SCLD6A400LSIG SCLD6B400LSIG<br />

500 SLD6A500LSIG SLD6B500LSIG SHLD6A500LSIG SHLD6B500LSIG SCLD6A500LSIG SCLD6B500LSIG<br />

600 SLD6A600LSIG SLD6B600LSIG SHLD6A600LSIG SHLD6B600LSIG SCLD6A600LSIG SCLD6B600LSIG<br />

Trip Unit Adjustable Functions<br />

Suffix<br />

Letter<br />

Code<br />

Trip<br />

Type<br />

Cont<br />

Current<br />

Setting<br />

Long<br />

Time<br />

Delay<br />

Instantaneous<br />

Pick Up<br />

LI LI u u u<br />

Short<br />

Time<br />

Pick Up<br />

Short<br />

Time<br />

Fixed<br />

Delay<br />

Short<br />

Time<br />

l 2 t<br />

Delay<br />

Ground<br />

Fault<br />

Pick Up<br />

LIG LIG u u u u u<br />

LSI LSI u u u u u u<br />

LSIG LSIG u u u u u u u u<br />

Ground<br />

Fault<br />

Delay<br />

Ordering Information<br />

Pricing information for all Digital<br />

Sentron Series SLD Frames is<br />

for complete breaker only – price<br />

required lugs as separate items –<br />

lugs are suitable for 75°C Wire.<br />

SLD6, SHLD6 and SCLD6 are<br />

acceptable for reverse connection<br />

application.<br />

Interrupting Ratings<br />

Breaker<br />

Type<br />

RMS Symmetrical kA<br />

UL 489 (File E10848)<br />

240V AC 480V AC 600V AC<br />

SLD6-B 65 35 25<br />

SHLD6-B 100 65 35<br />

SCLD6-B 200 150 100<br />

Neutral Transformers<br />

Ampere Rating Catalog Number<br />

300 N03SJD<br />

400 N04SJD<br />

500 N05SLD<br />

600 N06SLD<br />

Shipping Weights<br />

Breaker<br />

Type<br />

Number per<br />

Carton<br />

SLD6-B 1 20<br />

SHLD6-B 1 20<br />

SCLD6-B 1 33<br />

Shipping<br />

Weight (lbs)<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Note: “G” suffix in catalog number denotes circuit<br />

breaker for 3-phase, 3-wire circuits.<br />

For 3-phase, 4-wire, order correct 4th wire (neutral)<br />

transformer as separate and additional item.<br />

For ordering information and terminal connectors see<br />

page 7-121; for enclosures, see page 7-122.<br />

100% Rated – Not available in SLD6 Frame.<br />

All breakers built to order. Allow 2-3 weeks for delivery.<br />

a Advanced trip unit equipped with DAS / Maintenance<br />

Mode. Requires customer-supplied 24V external power<br />

supply, maintenance switch and light.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-123


Molded Case Circuit Breakers<br />

Internal Accessories<br />

Revised on 08/31/20<br />

Selection<br />

Accessories for:<br />

JD 400A Frame<br />

LD 600A Frame<br />

LMD 800A Frame<br />

SJD 400A Frame<br />

SLD 600A Frame<br />

Shunt Trip Combinations<br />

Control Voltage 1 Shunt Trip<br />

1 Shunt Trip and<br />

1 Auxiliary Switch<br />

AC DC Catalog Number Catalog Number<br />

024 S17JLD6 —<br />

048 S18JLD6s —<br />

120 S01JLD6 S01JLD62A<br />

240 S03JLD6 S03JLD62A<br />

277 S15JLD6s S15JLD64As<br />

480 S04JLD6 —<br />

012 S16JLD6s S16JLD62As<br />

024 S07JLD6 S07JLD62A<br />

048 S09JLD6s S09JLD62A<br />

125 S11JLD6 S11JLD62As<br />

250 S13JLD6s S13JLD62As<br />

Undervoltage Trip Combinations<br />

Control Voltage<br />

1 Undervoltage Trip<br />

1 Undervoltage Trip and<br />

1 Auxiliary Switch<br />

1 Undervoltage Trip and<br />

2 Auxiliary Switches<br />

S01JLD6<br />

AC DC Catalog Number Catalog Number Catalog Number<br />

120 U01JLD6 U01JLD62A U01JLD62AA<br />

208 U02JLD6s U02JLD62As U02JLD62AAs<br />

240 U03JLD6 U03JLD62As U03JLD62AAs<br />

480 U06JLD6 U06JLD64As U06JLD64AAs<br />

024 U13JLD6 U13JLD62A U13JLD62AA<br />

048 U14JLD6s U14JLD62As U14JLD62AAs<br />

125 U10JLD6s U10JLD62As U10JLD62AAs<br />

Auxiliary Switch Combinations<br />

Maximum<br />

Voltage 1 Form C 2 Form C<br />

AC DC Catalog Number Catalog Number<br />

480 250 A01JLD64 A02JLD64<br />

— 24 A01JLDLV A02JLDLV<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Alarm Switch Combinations<br />

Maximum<br />

Voltage<br />

1 Alarm Switch<br />

1 Alarm Switch and<br />

1 Auxiliary Switch<br />

1 Alarm Switch and<br />

2 Auxiliary Switches<br />

AC DC Catalog Number Catalog Number CatalogNumber<br />

480 250 B01JLD64 A01JLD64B A02JLD64B<br />

ETU Testing Unit<br />

Breaker Type Description Catalog Number<br />

SJD, SLD, SMD, Power Stick<br />

EPSP18V<br />

SND, SPD<br />

Spare cable for Power Stick COMPCA<br />

The EPSP18V Power Stick is a hand-held, battery-operated power supply<br />

that can be used for trip testing the Sensitrip IV electronic trip units.<br />

Requires two 9V batteries.<br />

Note: Accessory modules can only be added to right<br />

side pole of solid state SJD and SLD frame circuit<br />

breakers. No accessories can be added if<br />

mechanical interlock is used. All accessories on this<br />

page are useable on superseded JD2, JJ6, JL6, HJ6,<br />

SJL, LJ6, LL6, HL6 and SLL circuit breakers.<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

7-124<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

LMD 800A Frame Sentron Series<br />

Selection<br />

Type LMXD6 ad<br />

Blue Label<br />

Non-Interchangeable Trip (Assembled Circuit Breaker<br />

without Lugs)<br />

Continuous<br />

Current Rating<br />

@ 40°C<br />

Type LMD6 d<br />

Interchangeable Trip<br />

Continuous<br />

Current Rating<br />

@ 40°C<br />

2-Pole (3-Pole Width)<br />

Catalog Number<br />

3-Pole<br />

Catalog Number<br />

500 — LMXD63B500n<br />

600 LMXD62B600n LMXD63B600<br />

700 LMXD62B700n LMXD63B700<br />

800 LMXD62B800 LMXD63B800<br />

Instantaneous Adjustment Trip Range<br />

Blue Label<br />

Complete Breaker<br />

Unassembled w/Lugs Frame Only Trip Unit Only<br />

Catalog Number Catalog Number Catalog Number<br />

2-Pole 600V AC, 250V DC (3-Pole Width)<br />

500 LMD62B500n LMD62T500n<br />

600 LMD62B600n LMD62F800n LMD62T600n<br />

700 LMD62B700n LMD62T700n<br />

800 LMD62B800n LMD62T800n<br />

3-Pole 600V AC, 500V DC b<br />

500 LMD63B500n LMD63T500n<br />

600 LMD63B600n LMD63F800 LMD63T600n<br />

700 LMD63B700n LMD63T700n<br />

800 LMD63B800 LMD63T800<br />

Nominal Instantaneous Values<br />

Ampere Rating Low +/- 20% 2 3 4 5 6 7 High +/- 20%<br />

Tolerance<br />

Tolerance<br />

500-600 3000 3430 3860 4290 4710 5140 5570 6000<br />

700-800 3200 3500 3700 4200 4700 6400 7300 8000<br />

Ordering Information<br />

Complete Breaker Unassembled<br />

with Lugs<br />

Prices of LMD6 and HLMD6 breakers<br />

include frame, trip, and both line<br />

and load lugs (TA3K500). These<br />

catalog numbers include the frame,<br />

trip and lugs separately packaged.<br />

For applications requiring different<br />

lugs, order individual items as<br />

needed.<br />

Complete Breaker Assembled<br />

without Lugs<br />

Prices of LMXD6 and HLMXD6<br />

include frame with<br />

non-interchangeable trip unit<br />

installed only. Order required lugs<br />

separately. For line and load lugs<br />

(TA3K500) installed, add suffix “L”<br />

to catalog number (add 2 times list<br />

price of lugs for each pole).<br />

50°C Applications see page 7-156.<br />

400Hz Applications see page 7-156.<br />

Shipping Weights<br />

Number of Number per Shipping<br />

Poles Carton Weight (lbs.)<br />

LMD6, HLMD6, LMXD6, HLMXD6<br />

Complete Breaker (less terminals)<br />

2 1 53<br />

3 1 61.5<br />

LMD6, HLMD6 Frame Only<br />

2 1 42.25<br />

3 1 46<br />

LMD6, HLMD6 Trip Unit Only<br />

2 1 4.5<br />

3 1 6.5<br />

Lugs c for 75°C Wire<br />

Cables<br />

Catalog per Wire<br />

Number Lug Range<br />

TA2K500 1, 2 #1-500 kcmil Cu/Al<br />

TA3K500 1-3 #1/0-500 kcmil Cu/Al<br />

TA2N750 1, 2 500-750 kcmil Cu/Al<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

a LMXD6 circuit breakers are UL Listed for reverse<br />

connected applications.<br />

b When wired as shown on page 7-4, this circuit breaker is<br />

UL listed and rated for use on 500VDC ungrounded UPS<br />

systems only.<br />

Product Category MCCB<br />

c See Note: A, page 7-153.<br />

d HACR rated.<br />

Modifications page 7-156<br />

Enclosures Section 6<br />

Accessories pages 7-127 and 7-160 to 7-165<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-125


Molded Case Circuit Breakers<br />

LMD 800A Frame Sentron Series<br />

Selection/Dimensions<br />

Type HLMXD6 ad<br />

Black Label<br />

Non-Interchangeable Trip (Assembled Circuit Breaker<br />

Without Lugs)<br />

Continuous<br />

Current Rating<br />

@ 40°C<br />

500<br />

2-Pole<br />

600V AC/250V DC<br />

Catalog Number<br />

3-Pole<br />

600V AC/500V DC<br />

Catalog Number<br />

HLMXD63B500n<br />

600<br />

For 2-pole application<br />

HLMXD63B600n<br />

use outside poles of<br />

700<br />

3-pole circuit breaker<br />

HLMXD63B700n<br />

800 HLMXD63B800<br />

Type HLMD6 d<br />

Interchangeable Trip<br />

Continuous<br />

Current Rating<br />

@ 40°C<br />

Black Label<br />

Complete Breaker<br />

Unassembled Frame Only Trip Unit Only<br />

Catalog Number Catalog Number Catalog Number<br />

2-Pole 600V AC, 250V DC (3-Pole Width)<br />

500 HLMD62B500n<br />

LMD62T500n<br />

600 HLMD62B600n LMD62T600n<br />

HLMD62F800n<br />

700 HLMD62B700n LMD62T700n<br />

800 HLMD62B800n LMD62T800n<br />

3-Pole 600V AC, 500V DC c<br />

500 HLMD63B500<br />

LMD63T500n<br />

600 HLMD63B600 LMD63T600n<br />

HLMD63F800<br />

700 HLMD63B700 LMD63T700n<br />

800 HLMD63B800 LMD63T800<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Interrupting Ratings<br />

UL 489A IR<br />

RMS Symmetrical Amperes (KA)<br />

Breaker<br />

Volts AC<br />

Volts DC<br />

Type 240 480 600 250 500<br />

LMD6, LMXD6 65 50 25 30 (2-P) 25 (3-P)<br />

HLMD6, HLMXD6 100 065 050 30 (2-P) 50 (3-P)<br />

Dimensions (in inches)<br />

Breaker<br />

Type W L D D1<br />

LMD6,<br />

LMXD6,<br />

HLMD6, 7.5 16 4.5 5.93<br />

HLMXD6<br />

LMXD6-ETI b<br />

Enclosures<br />

Type<br />

Catalog Number<br />

1 LMD1<br />

3R<br />

LMD3R<br />

12 LMD12n<br />

Neutral<br />

W63623<br />

For inches / millimeters conversion, see Application Data section.<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

a HLMXD6 circuit breakers are UL Listed for reverse<br />

connection applications.<br />

b LMXD6-ETI, see page 7-140 for catalog information.<br />

c When wired as shown on page 7-4, this circuit breaker<br />

is UL listed and rated for use on 500VDC ungrounded<br />

UPS systems only.<br />

d HACR rated.<br />

7-126<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

Internal Accessories<br />

Revised on 08/31/20<br />

Selection<br />

Accessories for:<br />

JD 400A Frame<br />

LD 600A Frame<br />

LMD 800A Frame<br />

SJD 400A Frame<br />

SLD 600A Frame<br />

Shunt Trip Combinations<br />

Control Voltage 1 Shunt Trip<br />

1 Shunt Trip and<br />

1 Auxiliary Switch<br />

AC DC Catalog Number Catalog Number<br />

024 S17JLD6 —<br />

048 S18JLD6s —<br />

120 S01JLD6 S01JLD62A<br />

240 S03JLD6 S03JLD62A<br />

277 S15JLD6s S15JLD64As<br />

480 S04JLD6 —<br />

012 S16JLD6s S16JLD62As<br />

024 S07JLD6 S07JLD62A<br />

048 S09JLD6s S09JLD62A<br />

125 S11JLD6 S11JLD62As<br />

250 S13JLD6s S13JLD62As<br />

Undervoltage Trip Combinations<br />

Control Voltage<br />

1 Undervoltage Trip<br />

1 Undervoltage Trip and<br />

1 Auxiliary Switch<br />

1 Undervoltage Trip and<br />

2 Auxiliary Switches<br />

S01JLD6<br />

AC DC Catalog Number Catalog Number Catalog Number<br />

120 U01JLD6 U01JLD62A U01JLD62AA<br />

208 U02JLD6s U02JLD62As U02JLD62AAs<br />

240 U03JLD6 U03JLD62As U03JLD62AAs<br />

480 U06JLD6 U06JLD64As U06JLD64AAs<br />

024 U13JLD6 U13JLD62A U13JLD62AA<br />

048 U14JLD6s U14JLD62As U14JLD62AAs<br />

125 U10JLD6s U10JLD62As U10JLD62AAs<br />

Auxiliary Switch Combinations<br />

Maximum<br />

Voltage 1 Form C 2 Form C<br />

AC DC Catalog Number Catalog Number<br />

480 250 A01JLD64 A02JLD64<br />

— 24 A01JLDLV A02JLDLV<br />

Alarm Switch Combinations<br />

Maximum<br />

Voltage<br />

1 Alarm Switch<br />

1 Alarm Switch and<br />

1 Auxiliary Switch<br />

1 Alarm Switch and<br />

2 Auxiliary Switches<br />

AC DC Catalog Number Catalog Number CatalogNumber<br />

480 250 B01JLD64 A01JLD64B A02JLD64B<br />

ETU Testing Unit<br />

Breaker Type Description Catalog Number<br />

SJD, SLD, SMD, Power Stick<br />

EPSP18V<br />

SND, SPD<br />

Spare cable for Power Stick COMPCA<br />

The EPSP18V Power Stick is a hand-held, battery-operated power supply<br />

that can be used for trip testing the Sensitrip IV electronic trip units.<br />

Requires two 9V batteries.<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Note: Accessory modules can only be added to right<br />

side pole of solid state SJD and SLD frame circuit<br />

breakers. No accessories can be added if<br />

mechanical interlock is used. All accessories on this<br />

page are useable on superseded JD2, JJ6, JL6, HJ6,<br />

SJL, LJ6, LL6, HL6 and SLL circuit breakers.<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-127


Molded Case Circuit Breakers<br />

MD 800A Frame Sentron Series<br />

Revised on 12/31/19<br />

Selection<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Type MXD6 af<br />

Blue Label<br />

Non-Interchangeable Trip (Assembled Circuit Breaker<br />

Without Lugs)<br />

Continuous<br />

Current Rating 2-Pole b<br />

3-Pole<br />

@ 40°C<br />

Catalog Number<br />

Catalog Number<br />

600 MXD62B600n MXD63B600<br />

700 MXD62B700n MXD63B700<br />

800 MXD62B800n MXD63B800<br />

Type MD6 f<br />

Instantaneous Adjustment Trip Range<br />

Blue Label<br />

Interchangeable Trip<br />

Continuous Complete Breaker<br />

Current Rating Unassembled with Lugs Frame Only Trip Unit Only<br />

@ 40°C<br />

Catalog Number Catalog Number Catalog Number<br />

2-Pole 600V AC, 250V DC b<br />

500 MD62B500n<br />

MD62T500n<br />

600 MD62B600n MD62T600n<br />

MD62F800n<br />

700 MD62B700n MD62T700n<br />

800 MD62B800n MD62T800n<br />

3-Pole 600V AC, 500V DC c<br />

500 MD63B500<br />

MD63T500<br />

600 MD63B600 MD63T600<br />

MD63F800<br />

700 MD63B700 MD63T700<br />

800 MD63B800 MD63T800<br />

Lugs d<br />

Catalog<br />

Number<br />

Cables<br />

Per Lug<br />

Lugs<br />

Per Kit<br />

Wire<br />

Range<br />

TA2K500 1-2 1 #1-500 kcmil Cu/Al<br />

TA3K500 1-3 1 1/0-500 kcmil Cu/Al<br />

TC2K500 1-2 1 #1-500 kcmil Cu<br />

Kits<br />

2TA2N8750 1-2 2 500-750 kcmil Cu/Al<br />

3TA2N8750 3<br />

2TA3N8750 1-3 2 500-750 kcmil Cu/Al<br />

3TA3N8750 3<br />

2TA4N8500 1-4 2 250-500 kcmil Cu/Al<br />

3TA4N8500 3<br />

2TA4P8500 1-4 2 250-500 kcmil Cu/Al<br />

3TA4P8500 3<br />

Ampere<br />

Nominal Instantaneous Values<br />

Rating Low +/- 20% 2 3 4 5 6 7 High +/- 20%<br />

Tolerance<br />

Tolerance<br />

500 3000 3430 3860 4280 4710 5140 5570 6000<br />

600–800 4000 4570 5140 5710 6280 6850 7420 8000<br />

Ordering Information<br />

Complete Breaker Unassembled<br />

with Lugs<br />

Pricing information for MD6 and<br />

HMD6 breakers includes frame, trip,<br />

and both line and load lugs<br />

(TA3K500). When ordered by these<br />

catalog numbers, the customer will<br />

receive the frame, trip and lugs<br />

separately packaged. For<br />

applications requiring different lugs,<br />

order individual items as needed.<br />

Complete Breaker Assembled without<br />

Lugs<br />

Prices of MXD6, HMXD6 and<br />

CMD6 include frame with<br />

non-interchangeable trip units<br />

installed only. Order required lugs<br />

separately. For line and load lugs<br />

(TA3K500) installed, add suffix “L”<br />

to catalog number (add 2 times list<br />

price of lugs for each pole).<br />

100% Rated e 3-Pole Only<br />

Types MXD6, HMXD6 and CMD6<br />

breakers are available with 100%<br />

ratings. To order add suffix “H” to<br />

catalog number, and 10% to list<br />

price. 100% rated MD breakers<br />

require the use of 90°C cable<br />

sized at 75°C ampacity and lugs<br />

3TA4P8500 or 3TA2N8750.<br />

50°C Applications see page 7-156.<br />

400Hz Applications see page 7-156.<br />

Shipping Weights<br />

Number of<br />

Poles<br />

Number per<br />

Carton<br />

Shipping<br />

Weight (lbs.)<br />

MD6, HMD6, HMXD6, CMD6 Complete Breaker<br />

Assembled (less lugs)<br />

2 1 53<br />

3 1 61.5<br />

MD6, HMD6 Frame Only<br />

2 1 42.25<br />

3 1 46<br />

MD6, HMD6 Trip Unit Only<br />

2 1 4.5<br />

3 1 6.5<br />

SMD6 Breaker<br />

3 1 61.5<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

a MXD6 circuit breakers are UL Listed for reverse<br />

connection applications.<br />

b 2-pole units available in 3-pole width only.<br />

c When wired as shown on page 7-4, this circuit breaker<br />

is UL listed and rated for use on 500V DC ungrounded<br />

UPS systems.<br />

d See Note: A, page 7-153.<br />

e 80% rated breakers with the CE mark will also be<br />

marked in the 100% rated version.<br />

f HACR rated.<br />

Note: MD frame qualified to UL489 supplement B “NAVAL”.<br />

See page 7-156 for additional information.<br />

Enclosures<br />

Type<br />

Catalog Number<br />

1 MND61<br />

3R<br />

MND63<br />

12 MND612n<br />

Neutral<br />

W63623<br />

Modifications page 7-156<br />

Enclosures Section 6<br />

Accessories pages 7-131 and 7-160 to 7-165<br />

7-128<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

MD 800A Frame Sentron Series<br />

Revised on 05/31/18<br />

Selection/Dimensions<br />

Type HMXD6 ae<br />

Black Label<br />

Non-Interchangeable Trip (Assembled Circuit Breaker<br />

Without Lugs)<br />

Continuous<br />

Current Rating<br />

@ 40°C<br />

2-Pole<br />

600V AC/250V DC<br />

Catalog Number<br />

3-Pole<br />

600V AC/500V DC<br />

Catalog Number<br />

HMXD63B600n<br />

600 For 2-pole application<br />

700 use outside poles of HMXD63B700n<br />

3-pole circuit breaker<br />

800 HMXD63B800<br />

Type HMD6 e<br />

Interchangeable Trip<br />

Continuous<br />

Current Rating<br />

@ 40°C<br />

Black Label<br />

Complete Breaker<br />

Unassembled w/Lugs Frame Only Trip Unit Only<br />

Catalog Number Catalog Number Catalog Number<br />

2-Pole 600V AC, 250V DC b<br />

500 HMD62B500n MD62T500n<br />

600 HMD62B600n<br />

HMD62F800n<br />

MD62T600n<br />

700 HMD62B700n MD62T700n<br />

800 HMD62B800n MD62T800n<br />

3-Pole 600V AC, 500V DC d<br />

500 HMD63B500 MD63T500<br />

600 HMD63B600<br />

HMD63F800<br />

MD63T600<br />

700 HMD63B700 MD63T700<br />

800 HMD63B800 MD63T800<br />

Type CMD6 ae<br />

Fuseless Current Limiting<br />

Red Label<br />

Non-Interchangeable Trip (Assembled Circuit Breaker<br />

Without Lugs)<br />

Continuous<br />

Current Rating<br />

@ 40°C<br />

2-Pole<br />

600V AC/250V DC<br />

Catalog Number<br />

Interrupting Ratings<br />

3-Pole<br />

600V AC/500V DC<br />

Catalog Number<br />

CMD63B600n<br />

600 For 2-pole application<br />

700 use outside poles of CMD63B700n<br />

3-pole circuit breaker<br />

800 CMD63B800<br />

UL 489 AIR—File E10848<br />

IEC 947-2 AIR f<br />

RMS Symmetrical Amperes (KA)<br />

Volts AC (50/60HZ)<br />

Breaker<br />

Volts AC Volts DC 220/240 380/415 500<br />

Type 240 480 600 250 500 d (lcu) (lcs) (lcu) (lcs) (lcu) (lcs<br />

MD6, MXD6 065 050 25 30 (2-P) 25 (3-P) 065 033 040 20 — —<br />

HMD6, HMXD6 100 065 50 30 (2-P) 50 (3-P) 100 050 065 33 — —<br />

CMD6 200 100 65 — 50 (3-P) — — — — — —<br />

Lug<br />

When wire lug shield NDTS is used.<br />

Note: NDTS lug shields are required when oversized lugs<br />

are used. The kits include the NDTS shield.<br />

Dimensions (in inches)<br />

(To<br />

Breaker<br />

Handle)<br />

Type W L D D1<br />

MD6, MXD6, HMD6,<br />

HMXD6, CMD6,<br />

MXD6-ETI, CMD6-ETI,<br />

9 16 6 8.25<br />

SMD6-B, SHMD6-B,<br />

and SCMD6-B<br />

with lug shields 9 24 6 8.25<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

For inches / millimeters conversion, see Application Data section.<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

a HMXD6 and CMD circuit breakers are UL listed for<br />

reverse connection applications.<br />

b 2-pole units available in 3-pole width only.<br />

c MXD6-ETI, CMD6-ETI see page 7-140 for catalog information.<br />

Product Category MCCB<br />

d When wired as shown on page 7-4, this circuit breaker is<br />

UL listed and rated for use on 500V DC ungrounded UPS<br />

systems only.<br />

e HACR rated.<br />

f Only applicable to interchangable trip unit types:<br />

MXD6, HMXD6<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-129


Molded Case Circuit Breakers<br />

SMD 800A Frame Digital Solid State Sentron Sensitrip IV Series<br />

Revised on 12/31/19<br />

Selection<br />

Current Limiting<br />

Type SMD6 Type SHMD6-B Type SCMD6-B<br />

Blue Label Black Label Red Label<br />

Max 3-Pole, 600V AC 3-Pole, 600V AC 3-Pole, 600V AC<br />

Current<br />

Rating<br />

Catalog Number<br />

(Advanced trip unit) c<br />

Catalog Number<br />

(Basic trip unit)<br />

Catalog Number<br />

(Advanced trip unit) c<br />

Catalog Number<br />

(Basic trip unit)<br />

Catalog Number<br />

(Advanced trip unit) c<br />

Catalog Number<br />

(Basic trip unit)<br />

600 SMD6A600LI SMD6B600LI SHMD6A600LI SHMD6B600LI SCMD6A600LI SCMD6B600LI<br />

700 SMD6A700LI SMD6B700LI SHMD6A700LI SHMD6B700LI SCMD6A700LI SCMD6B700LI<br />

800 SMD6A800LI SMD6B800LI SHMD6A800LI SHMD6B800LI SCMD6A800LI SCMD6B800LI<br />

600 SMD6A600LIG SMD6B600LIG SHMD6A600LIG SHMD6B600LIG SCMD6A600LIG SCMD6B600LIG<br />

700 SMD6A700LIG SMD6B700LIG SHMD6A700LIG SHMD6B700LIG SCMD6A700LIG SCMD6B700LIG<br />

800 SMD6A800LIG SMD6B800LIG SHMD6A800LIG SHMD6B800LIG SCMD6A800LIG SCMD6B800LIG<br />

600 SMD6A600LSI SMD6B600LSI SHMD6A600LSI SHMD6B600LSI SCMD6A600LSI SCMD6B600LSI<br />

700 SMD6A700LSI SMD6B700LSI SHMD6A700LSI SHMD6B700LSI SCMD6A700LSI SCMD6B700LSI<br />

800 SMD6A800LSI SMD6B800LSI SHMD6A800LSI SHMD6B800LSI SCMD6A800LSI SCMD6B800LSI<br />

600 SMD6A600LSIG SMD6B600LSIG SHMD6A600LSIG SHMD6B600LSIG SCMD6A600LSIG SCMD6B600LSIG<br />

700 SMD6A700LSIG SMD6B700LSIG SHMD6A700LSIG SHMD6B700LSIG SCMD6A700LSIG SCMD6B700LSIG<br />

800 SMD6A800LSIG SMD6B800LSIG SHMD6A800LSIG SHMD6B800LSIG SCMD6A800LSIG SCMD6B800LSIG<br />

SMD 800A Frame – 100% Rated a<br />

Current Limiting<br />

Type SMD6-B Type SHMD6-B Type SCMD6-B<br />

Blue Label Black Label Red Label<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Max 3-Pole, 600V AC 3-Pole, 600V AC 3-Pole, 600V AC<br />

Current<br />

Rating<br />

Catalog Number<br />

(Advanced trip unit) c<br />

Catalog Number<br />

(Basic trip unit)<br />

Catalog Number<br />

(Advanced trip unit) c<br />

Catalog Number<br />

(Basic trip unit)<br />

Catalog Number<br />

(Advanced trip unit) c<br />

Catalog Number<br />

(Basic trip unit)<br />

600 SMD6A600LIH SMD6B600LIH SHMD6A600LIH SHMD6B600LIH SCMD6A600LIH SCMD6B600LIH<br />

700 SMD6A700LIH SMD6B700LIH SHMD6A700LIH SHMD6B700LIH SCMD6A700LIH SCMD6B700LIH<br />

800 SMD6A800LIH SMD6B800LIH SHMD6A800LIH SHMD6B800LIH SCMD6A800LIH SCMD6B800LIH<br />

600 SMD6A600LIGH SMD6B600LIGH SHMD6A600LIGH SHMD6B600LIGH SCMD6A600LIGH SCMD6B600LIGH<br />

700 SMD6A700LIGH SMD6B700LIGH SHMD6A700LIGH SHMD6B700LIGH SCMD6A700LIGH SCMD6B700LIGH<br />

800 SMD6A800LIGH SMD6B800LIGH SHMD6A800LIGH SHMD6B800LIGH SCMD6A800LIGH SCMD6B800LIGH<br />

600 SMD6A600LSIH SMD6B600LSIH SHMD6A600LSIH SHMD6B600LSIH SCMD6A600LSIH SCMD6B600LSIH<br />

700 SMD6A700LSIH SMD6B700LSIH SHMD6A700LSIH SHMD6B700LSIH SCMD6A700LSIH SCMD6B700LSIH<br />

800 SMD6A800LSIH SMD6B800LSIH SHMD6A800LSIH SHMD6B800LSIH SCMD6A800LSIH SCMD6B800LSIH<br />

600 SMD6A600LSIGH SMD6B600LSIGH SHMD6A600LSIGH SHMD6B600LSIGH SCMD6A600LSIGH SCMD6B600LSIGH<br />

700 SMD6A700LSIGH SMD6B700LSIGH SHMD6A700LSIGH SHMD6B700LSIGH SCMD6A700LSIGH SCMD6B700LSIGH<br />

800 SMD6A800LSIGH SMD6B800LSIGH SHMD6A800LSIGH SHMD6B800LSIGH SCMD6A800LSIGH SCMD6B800LSIGH<br />

Ordering Information<br />

Pricing information for all Digital Sentron Series MD frames is for<br />

complete breaker only. Price requires lugs or lug kits as separate items.<br />

Lugs are suitable for 75°C wire or as noted. Connector wire ranges<br />

and cavities are established in conjunction with Table 6.1.4.2.1 of UL<br />

489 standards. Choose actual connector for circuit breakers based on<br />

customer requirements.<br />

Recommended Terminal Connectors<br />

Breaker Frame Ampere Rating Connector or Connector Kit<br />

MD 500-600 TA2K500<br />

MD 700-800 TA3K500<br />

Types SMD6-B, SHMD6-B and SCMD6-B are acceptable for reverse<br />

connection applications<br />

Trip Unit Adjustable Functions<br />

Suffix<br />

Letter<br />

Code<br />

Trip<br />

Type<br />

Cont<br />

Current<br />

Setting<br />

Long<br />

Time<br />

Delay<br />

Instantaneous<br />

Pick Up<br />

Short<br />

Time<br />

Pick Up<br />

Short<br />

Time<br />

Delay<br />

Ground<br />

Fault<br />

Pick Up<br />

LI LI u u u<br />

LIG LIG u u u u u<br />

LSI LSI u u u u u<br />

LSIG LSIG u u u u u u u<br />

Ground<br />

Fault<br />

Delay<br />

Lugs for 75° C Wire b<br />

Catalog<br />

Number<br />

Interrupting Ratings<br />

Breaker<br />

Type<br />

Cables<br />

per Lug<br />

RMS Symmetrical kA<br />

UL 489 (File E10848)<br />

240V<br />

AC<br />

480V<br />

AC<br />

Wire<br />

Range<br />

TA2K500 2 #1-500 kcmil Cu/Al<br />

TA3K500 3 #1-500 kcmil Cu/Al<br />

TC2K500 2 #1-500 kcmil Cu<br />

Kits (3 lugs/kit)<br />

3TA4N8500 4 250-500 kcmil Cu/Al<br />

3TA4P8500 4 250-500 kcmil Cu/Al<br />

3TA2N8750 2 500-750 kcmil Cu/Al<br />

3TA3N8750 3 500-750 kcmil Cu/Al<br />

600V<br />

AC<br />

SMD6-B 65 50 25<br />

SHMD6-B 100 65 50<br />

SCMD6-B 200 100 65<br />

Each kit contains<br />

the following:<br />

3TA4P8500 -<br />

3 connectors plus<br />

1 NDTS end barrier<br />

3TA3N8750 -<br />

3 connectors plus<br />

1 NDTS end barrier<br />

3TA2N8750 -<br />

3 connectors plus<br />

1 NDTS end barrier<br />

Neutral<br />

Transformers<br />

Ampere<br />

Rating Catalog Number<br />

600 N06SMDA<br />

700 N07SMDA<br />

800 N08SMDA<br />

Note: “G” suffix in catalog number denotes circuit<br />

breaker for 3-phase, 3-wire circuits.<br />

For 3-phase, 4-wire, order correct 4th wire (neutral)<br />

transformer as separate and additional item.<br />

All breakers built to order. Allow 2-3 weeks for delivery.<br />

a Use 2-3TA4P8500 or 2-3TA3N8750 for 3-pole. These kits<br />

are rated for 90°C wire. 90°C cable must be used and<br />

sized per 75°C ampacity.<br />

b For additional information, see Note: A, page 7-153.<br />

c Advanced trip unit equipped with DAS / Maintenance<br />

Mode. Requires customer-supplied 24V external power<br />

supply, maintenance switch and light.<br />

Enclosures Section 6<br />

Accessories pages 7-131 and 7-160 to 7-165<br />

7-130<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

Internal Accessories<br />

Revised on 08/31/20<br />

Selection<br />

Accessories for:<br />

MD/SMD 800A Frame<br />

ND/SND 1200A Frame<br />

PD/SPD 1600A Frame<br />

RD 2000A Frame<br />

Shunt Trip Combinations<br />

Control Voltage 1 Shunt Trip<br />

1 Shunt Trip and<br />

1 Auxiliary Switch<br />

AC DC Catalog Number Catalog Number<br />

120 S01MN6 S01MN64A<br />

208 S02MN6s —<br />

240 S03MN6 S03MN64As<br />

277 S15MN6s S15MN64As<br />

480 S04MN6s S04MN64As<br />

600 S06MN6s —<br />

012 S16MN6s S16MN64As<br />

024 S07MN6 S07MN64A<br />

048 S09MN6s —<br />

125 S11MN6 S11MN64As<br />

250 S13MN6s S13MN64As<br />

Undervoltage Trip Combinations<br />

Control Voltage<br />

1 Undervoltage Trip<br />

1 Undervoltage Trip and<br />

1 Auxiliary Switch<br />

1 Undervoltage Trip and<br />

2 Auxiliary Switches<br />

S01MN6<br />

Accessory modules can mount in either<br />

left hand or right hand poles of all circuit<br />

breakers, including solid state. Exception:<br />

when mechanical interlock is used.<br />

Accessories cannot be mounted in left<br />

pole.<br />

AC DC Catalog Number Catalog Number Catalog Number<br />

120 U01MN6 U01MN64A U01MN64AA<br />

208 U02MN6s U02MN64As U02MN64AAs<br />

240 U03MN6s U03MN64As U03MN64AAs<br />

277 U15MN6s U15MN64As U15MN64AAs<br />

480 U04MN6s U04MN64As U04MN64AAs<br />

600 U06MN6s — —<br />

024 U07MN6 U07MN64A U07MN64AA<br />

048 U09MN6s U09MN64As U09MN64AAs<br />

125 U11MN6s U11MN64As U11MN64AAs<br />

Auxiliary Switch Combinations<br />

Maximum<br />

Voltage 1 Form C 2 Form C<br />

AC DC Catalog Number Catalog Number<br />

480 250 A01MN64 A02MN64<br />

— 24 A01MNDLVs A02MNDLVs<br />

7<br />

Alarm Switch Combinations<br />

Maximum<br />

Voltage<br />

1 Alarm Switch<br />

1 Alarm Switch and<br />

1 Auxiliary Switch<br />

1 Alarm Switch and<br />

2 Auxiliary Switches<br />

AC DC Catalog Number Catalog Number Catalog Number<br />

480 250 B00MN64 A01MN64B A02MN64B<br />

ETU Testing Unit<br />

Breaker Type Description Catalog Number<br />

SJD, SLD, SMD, Power Stick<br />

EPSP18V<br />

SND, SPD<br />

Spare cable for Power Stick COMPCA<br />

The EPSP18V Power Stick is a hand-held, battery-operated power supply<br />

that can be used for trip testing the Sensitrip IV electronic trip units.<br />

Requires two 9V batteries.<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-131


Molded Case Circuit Breakers<br />

ND 1200A Frame Sentron Series<br />

Revised on 12/31/19<br />

Selection<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Type NXD6 ah<br />

Blue Label<br />

Non-Interchangeable Trip (Assembled Circuit Breaker<br />

Without Lugs)<br />

Continuous<br />

Current Rating<br />

@ 40°C<br />

2-Pole<br />

600V AC/250V DC<br />

Catalog Number<br />

Interrupting Ratings<br />

RMS Symmetrical Amperes (KA)<br />

UL 489 A IR<br />

3-Pole<br />

600V AC/500V DC<br />

Catalog Number<br />

0900 NXD62B900n NXD63B900<br />

1000 NXD62B100n NXD63B100<br />

1200 NXD62B120n NXD63B120<br />

Type ND6 h<br />

Interchangeable Trip<br />

Continuous<br />

Current Rating<br />

@ 40°C<br />

IEC 947-2 i<br />

Breaker<br />

Volts AC Volts DC Volts AC (50/60HZ)<br />

Type 240 480 600 250 500 c 220/240 380/415 500<br />

(lcu) (lcs) (lcu) (lcs) (lcu) (lcs)<br />

ND6, NXD6 65 50 25 30 (2-P) 25 (3-P) 65 33 40 20 — —<br />

HND6, HNXD6 100 65 50 30 (2-P) 50 (3-P) 100 50 65 33 — —<br />

CND6 200 100 65 — 50 (3-P) — — — — — —<br />

Instantaneous Adjustment Trip Range<br />

Blue Label<br />

Complete Breaker<br />

Unassembled with Lugs Frame Only Trip Unit Only<br />

Catalog Number Catalog Number Catalog Number<br />

2-Pole 600V AC, 250V DC b<br />

0800 ND62B800n<br />

MD62T800n<br />

0900 ND62B900n ND62T900n<br />

ND62F120<br />

1000 ND62B100n ND62T100n<br />

1200 ND62B120 ND62T120<br />

3-Pole 600V AC, 500V DC c<br />

0800 ND63B800<br />

MD63T800<br />

0900 ND63B900 ND63T900<br />

ND63F120<br />

1000 ND63B100 ND63T100<br />

1200 ND63B120 ND63T120<br />

Nominal Instantaneous Values<br />

+20% +20%<br />

Breaker Ampere Tolerance Tolerance<br />

Rating Low 2 3 4 5 6 7 High<br />

800 4000 4570 5140 5710 6280 6850 7420 08000<br />

900-1200 5000 5715 6430 7145 7860 8575 9290 10000<br />

Ordering Information<br />

Complete Breaker Unassembled<br />

with Lugs<br />

Prices of ND6 and HND6 breakers<br />

include frame, trip, and both line and<br />

load lugs (3TA4N8500). These catalog<br />

numbers are the frame, trip and lugs<br />

separately packaged. For applications<br />

requiring different lugs, order<br />

individual items as needed.<br />

Complete Breaker Assembled<br />

without Lugs<br />

Prices of NXD6, HNXD6, and<br />

CND6 include frame with<br />

non-interchangeable trip units<br />

installed only. Order required<br />

terminal connectors separately.<br />

For line and load lugs (3TA4N8500)<br />

installed, add suffix “L” to catalog<br />

number (add 2 times list price of<br />

lug kit).<br />

100% Rated (3-Pole only) g<br />

Types NXD6, HNXD6 and CND6<br />

breakers are available with 100%<br />

ratings. To order, add suffix “H” to<br />

catalog number, and add 10% to<br />

list price. 100% rated ND breakers<br />

require 90°C cable sized at 75°C<br />

ampacity and lug kit 3TA4P8500<br />

or 3TA3N8750.<br />

50°C Applications see page 7-156.<br />

400Hz Applications see page 7-156.<br />

Lugs f<br />

Catalog<br />

Number<br />

Cables<br />

per Lug<br />

Wire<br />

Range<br />

TA2K500 2 #1-500 kcmil Cu/Al<br />

TA3K500 3 #1-500 kcmil Cu/Al<br />

TC2K500 2 #1-500 kcmil Cu<br />

Kits (2 Kits required per breaker)<br />

2TA4P8500 d<br />

3TA4P8500 d 4 250-500 kcmil Cu/Al<br />

2TA4N8500 e<br />

3TA4N8500 e 4 250-500 kcmil Cu/Al<br />

2TA2N8750<br />

3TA2N8750<br />

2 500-750 kcmil Cu/Al<br />

2TA3N8750<br />

3TA3N8750<br />

3 500-750 kcmil Cu/Al<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

a NXD6 circuit breakers are UL listed for reverse<br />

connection applications.<br />

b 2-pole units available in 3-pole width only.<br />

c When wired as shown on page 7-4, this circuit breaker is<br />

UL listed and rated for use on 500VDC ungrounded UPS<br />

systems only.<br />

d Use 2 – 3TA4P8500 kits for 3-pole, or 2 – 2TA4P8500<br />

kits for 2-pole. Rated for 90° C cable. Use for 100% rated<br />

breakers.<br />

e Use 2 – 3TA4N8500 for 3-pole or 2 – 2TA4N8500 for<br />

2-pole. Rated for 75°C cable.<br />

f See Note: A, page 7-153.<br />

g 80% rated breakers with the CE mark will also be<br />

marked in the 100% rated version.<br />

h HACR rated.<br />

i Only applicable to interchangable trip unit types:<br />

NXD6, HNXD6.<br />

Note: ND frame qualified to UL489 supplement B “NAVAL”.<br />

See page 7-156 for additional information.<br />

Enclosures<br />

Type<br />

Catalog Number<br />

1 MND61<br />

3R<br />

MND63<br />

12 MND612n<br />

Neutral W63623<br />

Modifications page 7-156<br />

Enclosures Section 6<br />

Accessories pages 7-135 and 7-160 to 7-165<br />

7-132<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

ND 1200A Frame Sentron Series<br />

Revised on 02/06/18<br />

Selection/Dimensions<br />

Type HNXD6 ad<br />

Black Label<br />

Non-Interchangeable Trip (Assembled Circuit Breaker<br />

Without Lugs)<br />

Continuous<br />

Current Rating<br />

@ 40°C<br />

2-Pole<br />

600V AC/250V DC<br />

Catalog Number<br />

3-Pole<br />

600V AC/500V DC<br />

Catalog Number<br />

HNXD63B900<br />

0900 For 2-pole application<br />

1000 use outside poles of HNXD63B100<br />

1200 3-pole circuit breaker HNXD63B120<br />

Type HND6 d<br />

Interchangeable Trip<br />

Continuous<br />

Current Rating<br />

@ 40°C<br />

Black Label<br />

Complete Breaker<br />

Unassembled with Lugs Frame Only Trip Unit Only<br />

Catalog Number Catalog Number Catalog Number<br />

2-Pole 600V AC, 250V DC b<br />

0800<br />

0900<br />

For 2-pole application use outside poles of 3-pole circuit breaker<br />

1000<br />

1200<br />

3-Pole 600V AC, 500V DC c<br />

0800 HND63B800<br />

MD63T800<br />

0900 HND63B900 ND63T900<br />

HND63F120<br />

1000 HND63B100 ND63T100<br />

1200 HND63B120 ND63T120<br />

NXD63B120<br />

Type CND6 ad<br />

Fuseless Current Limiting<br />

Red Label<br />

Non-Interchangeable Trip (Assembled Circuit Breaker)<br />

Continuous<br />

Current Rating 2-Pole<br />

3-Pole<br />

@ 40°C<br />

Catalog Number<br />

Catalog Number<br />

0900 For 2-pole application, CND63B900n<br />

1000 use outside poles of CND63B100<br />

3-pole circuit breaker<br />

1200 CND63B120<br />

Shipping Weights<br />

Number of Number per Shipping<br />

Poles Carton Weight (lbs.)<br />

ND6, HND6, NXD6, HNXD6, CND6<br />

Assembled Breaker (less terminals)<br />

2 1 53<br />

3 1 61.5<br />

ND6, HND6 Frame Only<br />

2 1 42.25<br />

3 1 46<br />

ND6, HND6 Trip Unit Only<br />

2 1 04.5<br />

3 1 06.5<br />

Lugs<br />

When lugs shield NDTS is used.<br />

Note: NDTS lug shields are required when oversized lugs<br />

TA4P8500 or TA4N8500 are used. The kits include<br />

the NDTS shield.<br />

Dimensions (in inches)<br />

Breaker<br />

Type W L D D1<br />

ND6, NXD6, HND6,<br />

HNXD6, CND6,<br />

SND6-B, SHND6-B,<br />

9 16 6 8.25<br />

and SCND6-B<br />

with NDTS<br />

lug shield<br />

9 24 6 8.25<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

For inches / millimeters conversion, see Application Data section.<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

a HNXD6 and CND6 circuit breakers are UL Listed for<br />

reverse connection applications.<br />

b 2-pole units available in 3-pole width only.<br />

c When wired as shown on page 7-4, this circuit breaker is<br />

UL listed and rated for use on 500V DC ungrounded<br />

UPS systems only.<br />

d HACR rated.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-133


Molded Case Circuit Breakers<br />

SND 1200A Frame Digital Solid State Sentron Sensitrip IV Series b<br />

Revised on 02/28/19<br />

Selection<br />

Current Limiting<br />

Type SND6-B Type SHND6-B Type SCND6-B<br />

Blue Label Black Label Red Label<br />

Max 3-Pole, 600V AC 3-Pole, 600V AC 3-Pole, 600V AC<br />

Current<br />

Rating<br />

Catalog Number<br />

(Advanced trip unit) c<br />

Catalog Number<br />

(Basic trip unit)<br />

Catalog Number<br />

(Advanced trip unit) c<br />

Catalog Number<br />

(Basic trip unit)<br />

Catalog Number<br />

(Advanced trip unit) c<br />

Catalog Number<br />

(Basic trip unit)<br />

800 SND6A800LI SND6B800LI SHND6A800LI SHND6B800LI SCND6A800LI SCND6B800LI<br />

1000 SND6A100LI SND6B100LI SHND6A100LI SHND6B100LI SCND6A100LI SCND6B100LI<br />

1200 SND6A120LI SND6B120LI SHND6A120LI SHND6B120LI SCND6A120LI SCND6B120LI<br />

800 SND6A800LIG SND6B800LIG SHND6A800LIG SHND6B800LIG SCND6A800LIG SCND6B800LIG<br />

1000 SND6A100LIG SND6B100LIG SHND6A100LIG SHND6B100LIG SCND6A100LIG SCND6B100LIG<br />

1200 SND6A120LIG SND6B120LIG SHND6A120LIG SHND6B120LIG SCND6A120LIG SCND6B120LIG<br />

800 SND6A800LSI SND6B800LSI SHND6A800LSI SHND6B800LSI SCND6A800LSI SCND6B800LSI<br />

1000 SND6A100LSI SND6B100LSI SHND6A100LSI SHND6B100LSI SCND6A100LSI SCND6B100LSI<br />

1200 SND6A120LSI SND6B120LSI SHND6A120LSI SHND6B120LSI SCND6A120LSI SCND6B120LSI<br />

800 SND6A800LSIG SND6B800LSIG SHND6A800LSIG SHND6B800LSIG SCND6A800LSIG SCND6B800LSIG<br />

1000 SND6A100LSIG SND6B100LSIG SHND6A100LSIG SHND6B100LSIG SCND6A100LSIG SCND6B100LSIG<br />

1200 SND6A120LSIG SND6B120LSIG SHND6A120LSIG SHND6B120LSIG SCND6A120LSIG SCND6B120LSIG<br />

SND 1200A Frame – 100% Rated a<br />

Current Limiting<br />

Type SND6-B Type SHND6-B Type SCND6-B<br />

Blue Label Black Label Red Label<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Max 3-Pole, 600V AC 3-Pole, 600V AC 3-Pole, 600V AC<br />

Current<br />

Rating<br />

Catalog Number<br />

(Advanced trip unit) c<br />

Catalog Number<br />

(Basic trip unit)<br />

Catalog Number<br />

(Advanced trip unit) c<br />

Catalog Number<br />

(Basic trip unit)<br />

Catalog Number<br />

(Advanced trip unit) c<br />

Catalog Number<br />

(Basic trip unit)<br />

800 SND6A800LIH SND6B800LIH SHND6A800LIH SHND6B800LIH SCND6A800LIH SCND6B800LIH<br />

1000 SND6A100LIH SND6B100LIH SHND6A100LIH SHND6B100LIH SCND6A100LIH SCND6B100LIH<br />

1200 SND6A120LIH SND6B120LIH SHND6A120LIH SHND6B120LIH SCND6A120LIH SCND6B120LIH<br />

800 SND6A800LIGH SND6B800LIGH SHND6A800LIGH SHND6B800LIGH SCND6A800LIGH SCND6B800LIGH<br />

1000 SND6A100LIGH SND6B100LIGH SHND6A100LIGH SHND6B100LIGH SCND6A100LIGH SCND6B100LIGH<br />

1200 SND6A120LIGH SND6B120LIGH SHND6A120LIGH SHND6B120LIGH SCND6A120LIGH SCND6B120LIGH<br />

800 SND6A800LSIH SND6B800LSIH SHND6A800LSIH SHND6B800LSIH SCND6A800LSIH SCND6B800LSIH<br />

1000 SND6A100LSIH SND6B100LSIH SHND6A100LSIH SHND6B100LSIH SCND6A100LSIH SCND6B100LSIH<br />

1200 SND6A120LSIH SND6B120LSIH SHND6A120LSIH SHND6B120LSIH SCND6A120LSIH SCND6B120LSIH<br />

800 SND6A800LSIGH SND6B800LSIGH SHND6A800LSIGH SHND6B800LSIGH SCND6A800LSIGH SCND6B800LSIGH<br />

1000 SND6A100LSIGH SND6B100LSIGH SHND6A100LSIGH SHND6B100LSIGH SCND6A100LSIGH SCND6B100LSIGH<br />

1200 SND6A120LSIGH SND6B120LSIGH SHND6A120LSIGH SHND6B120LSIGH SCND6A120LSIGH SCND6B120LSIGH<br />

Trip Unit Adjustable Functions<br />

Suffix<br />

Letter<br />

Code<br />

Trip<br />

Type<br />

Cont<br />

Current<br />

Setting<br />

Long<br />

Time<br />

Delay<br />

Instantaneous<br />

Pick Up<br />

Short<br />

Time<br />

Pick Up<br />

Short<br />

Time<br />

Fixed<br />

Pick Up<br />

Neutral Transformers<br />

Ampere<br />

Rating<br />

Short<br />

Time I 2 t<br />

Delay<br />

Ground<br />

Fault<br />

Pick Up<br />

LI LI u u u<br />

LIG LIG u u u u u<br />

LSI LSI u u u u u u<br />

LSIG LSIG u u u u u u u u<br />

Interrupting Ratings<br />

Breaker RMS Symmetrical kA UL 489 (File E10848)<br />

Type 240V AC 480V AC 600V AC<br />

SND6-B 65 50 25<br />

SHND6-B 100 65 50<br />

SCND6-B 200 100 65<br />

Catalog<br />

Number<br />

800 N08SMDA<br />

1000 N10SNDA<br />

1200 N12SNDA<br />

Ground<br />

Fault<br />

Delay<br />

For inches / millimeters conversion, see Application Data section.<br />

All breakers built to order. Allow 2–3 weeks for delivery.<br />

For ordering information and terminal connectors,<br />

and enclosures, see page 7-132.<br />

Note: “G” suffix in catalog number denotes circuit<br />

breaker for 3-phase, 3-wire circuits.<br />

For 3-phase, 4-wire, order correct 4th wire (neutral)<br />

transformer as separate and additional item.<br />

a Use 2-3TA4P8500 or 2-3TA3N8750 for 3-pole. These kits<br />

are rated for 90°C wire. 90°C cable must be used and<br />

sized per 75°C ampacity.<br />

b SND6, SHND6 and SCND6 circuit breakers are UL Listed<br />

for reverse connection applications.<br />

c Advanced trip unit equipped with DAS / Maintenance<br />

Mode. Requires customer-supplied 24V external power<br />

supply, maintenance switch and light.<br />

7-134<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

Internal Accessories<br />

Revised on 08/31/20<br />

Selection<br />

Accessories for:<br />

MD/SMD 800A Frame<br />

ND/SND 1200A Frame<br />

PD/SPD 1600A Frame<br />

RD 2000A Frame<br />

Shunt Trip Combinations<br />

Control Voltage 1 Shunt Trip<br />

1 Shunt Trip and<br />

1 Auxiliary Switch<br />

AC DC Catalog Number Catalog Number<br />

120 S01MN6 S01MN64A<br />

208 S02MN6s —<br />

240 S03MN6 S03MN64As<br />

277 S15MN6s S15MN64As<br />

480 S04MN6s S04MN64As<br />

600 S06MN6s —<br />

012 S16MN6s S16MN64As<br />

024 S07MN6 S07MN64A<br />

048 S09MN6s —<br />

125 S11MN6 S11MN64As<br />

250 S13MN6s S13MN64As<br />

Undervoltage Trip Combinations<br />

Control Voltage<br />

1 Undervoltage Trip<br />

1 Undervoltage Trip and<br />

1 Auxiliary Switch<br />

1 Undervoltage Trip and<br />

2 Auxiliary Switches<br />

S01MN6<br />

Accessory modules can mount in either<br />

left hand or right hand poles of all circuit<br />

breakers, including solid state. Exception:<br />

when mechanical interlock is used.<br />

Accessories cannot be mounted in left<br />

pole.<br />

AC DC Catalog Number Catalog Number Catalog Number<br />

120 U01MN6 U01MN64A U01MN64AA<br />

208 U02MN6s U02MN64As U02MN64AAs<br />

240 U03MN6s U03MN64As U03MN64AAs<br />

277 U15MN6s U15MN64As U15MN64AAs<br />

480 U04MN6s U04MN64As U04MN64AAs<br />

600 U06MN6s — —<br />

024 U07MN6 U07MN64A U07MN64AA<br />

048 U09MN6s U09MN64As U09MN64AAs<br />

125 U11MN6s U11MN64As U11MN64AAs<br />

Auxiliary Switch Combinations<br />

Maximum<br />

Voltage 1 Form C 2 Form C<br />

AC DC Catalog Number Catalog Number<br />

480 250 A01MN64 A02MN64<br />

— 24 A01MNDLVs A02MNDLVs<br />

7<br />

Alarm Switch Combinations<br />

Maximum<br />

Voltage<br />

1 Alarm Switch<br />

1 Alarm Switch and<br />

1 Auxiliary Switch<br />

1 Alarm Switch and<br />

2 Auxiliary Switches<br />

AC DC Catalog Number Catalog Number Catalog Number<br />

480 250 B00MN64 A01MN64B A02MN64B<br />

ETU Testing Unit<br />

Breaker Type Description Catalog Number<br />

SJD, SLD, SMD, Power Stick<br />

EPSP18V<br />

SND, SPD<br />

Spare cable for Power Stick COMPCA<br />

The EPSP18V Power Stick is a hand-held, battery-operated power supply<br />

that can be used for trip testing the Sensitrip IV electronic trip units.<br />

Requires two 9V batteries.<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-135


Molded Case Circuit Breakers<br />

PD 1600A Frame Sentron Series<br />

Selection<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Type PXD6 b Non-Interchangeable Trip e<br />

3-Pole 600V AC, 250-500V DC a<br />

Continuous<br />

Current<br />

Rating @ 40°C<br />

Blue Label<br />

Complete Breaker Assembled<br />

(Frame/Trip Unit Only) Mounting Assembly Lugs (6 required)<br />

Catalog Number Catalog Number Catalog Number<br />

1200 PXD63B120n MB9301<br />

1400 PXD63B140n -or- TA5P600<br />

1600 PXD63B160 MBR9302<br />

Type PD6 Interchangeable Trip e<br />

3-Pole 600V AC, 250-500V DC a<br />

Continuous<br />

Current<br />

Rating @<br />

40°C<br />

Complete Breaker<br />

Unassembled Frame Only Trip Unit Only<br />

Catalog<br />

Catalog Catalog<br />

Number<br />

Number Number<br />

Type HPXD6 b Non-Interchangeable Trip e<br />

3-Pole 600V AC, 250-500V DC a<br />

Blue Label<br />

Continuous Current<br />

Rating @ 40°C<br />

Complete Breaker Assembled (Frame/Trip Unit Only)<br />

Catalog Number<br />

1200 HPXD63B120n<br />

1400 HPXD63B140n<br />

1600 HPXD63B160<br />

Type CPD6 Non-Interchangeable Trip e<br />

Fuseless Current Limiting<br />

3-Pole 600V AC, 250-500V DC a<br />

Mounting<br />

Assembly<br />

Catalog<br />

Number<br />

Blue Label<br />

Lugs (6 required)<br />

Catalog<br />

Number<br />

1200 PD63B120n PD63T120n MB9301<br />

1400 PD63B140 PD63F160 PD63T140 -or- TA5P600<br />

1600 PD63B160 PD63T160 MBR9302<br />

Type HPD6 Interchangeable Trip e<br />

3-Pole 600V AC, 250-500V DC a<br />

Continuous<br />

Current<br />

Rating @<br />

40°C<br />

Complete Breaker<br />

Unassembled Frame Only Trip Unit Only<br />

Catalog<br />

Catalog Catalog<br />

Number<br />

Number Number<br />

Mounting<br />

Assembly<br />

Catalog<br />

Number<br />

Black Label<br />

Lugs (6 required)<br />

Catalog<br />

Number<br />

1200 HPD63B120n PD63T120n MB9301<br />

1400 HPD63B140 HPD63F160 PD63T140 -or- TA5P600<br />

1600 HPD63B160 PD63T160 MBR9302<br />

Red Label<br />

Continuous Current<br />

Rating @ 40°C<br />

Complete Breaker Assembled (Frame/Trip Unit Only)<br />

Catalog Number<br />

1200 CPD63B120n<br />

1400 CPD63B140n<br />

1600 CPD63B160n<br />

Ordering Instructions<br />

Complete Breaker Unassembled<br />

with Lugs<br />

Prices of PD6, HPD6, RD6, and HRD6<br />

type breakers include frame, trip,<br />

mounting base (MB9301), and both<br />

line and load lugs (PD Frame –<br />

TA5P600, RD Frame – TC5R600). When<br />

ordered by these catalog numbers, the<br />

customer will receive the frame, trip,<br />

mounting assembly and lugs<br />

separately packaged. For applications<br />

requiring different mounting base or<br />

lugs, order individual items as needed.<br />

Complete Breaker Assembled<br />

without Lugs<br />

Prices of PXD6, HPXD6, RXD6, HRXD6<br />

and CPD6 type breakers include frame<br />

with non-interchangeable trip unit<br />

installed only. Order required<br />

mounting base and lugs separately.<br />

100% Rated (3-Pole only)<br />

Types PXD6, HPXD6 breakers are<br />

available with 100% ratings. To order<br />

add suffix “H” to catalog number,<br />

and 10% to list price. 100% PD<br />

breakers require 90˚ C cable sized<br />

at 75˚ C ampacity and TC5R600 lugs.<br />

RD 2000A Frames not available with<br />

100% ratings.<br />

50°C Applications see page 7-156.<br />

400HZ Applications see page 7-156.<br />

Lugs (6 required per breaker) d<br />

No of<br />

Catalog Cables per<br />

Number Connector Wire Range<br />

TA5P600 1-5 300-600 kcmil Cu/Al<br />

TC5R600 1-5 300-600 kcmil Cu only<br />

TA4P750s 1-4 600-750 kcmil Cu/Al<br />

TA6R600 1-6 300-600 kcmil Cu/Al<br />

Interrupting Ratings<br />

UL 489 A IR<br />

RMS Symmetrical KA<br />

Breaker<br />

Volts AC<br />

Volts DC a<br />

Type 240 480 600 250 500<br />

PD6, PXD6 65 50 25 30 (2P) 25 (3P)<br />

HPD6, HPXD6 100 65 50 30 (2P) 50 (3P)<br />

CPD6 200 100 65 30 (2P) 50 (3P)<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

a Use two outside poles of a 3-pole circuit breaker for 250V<br />

b When wired as shown on page 7-4, this circuit breaker is<br />

UL listed and rated for use on 500V DC ungrounded UPS<br />

systems only.<br />

c PXD6, HPXD6 and CPD6 type circuit breakers are UL<br />

Listed for reverse feed applications.<br />

d For additional information See Note: A, page 7-153.<br />

e HACR rated.<br />

Note: PD frame qualified to UL489 supplement B “NAVAL”.<br />

See page 7-156 for additional information.<br />

7-136<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

SPD 1600A Frame Digital Solid State Sentron Sensitrip IV Series<br />

Revised on 05/31/18<br />

Selection/Dimensions<br />

Type SPD6-B<br />

Blue Label<br />

Type SHPD6-B<br />

Black Label<br />

Max 3-Pole, 600V AC<br />

3-Pole, 600V AC<br />

Current<br />

Rating<br />

Catalog Number<br />

(Advanced trip unit) c<br />

Catalog Number<br />

(Basic trip unit)<br />

Catalog Number<br />

(Advanced trip unit) c<br />

Catalog Number<br />

(Basic trip unit)<br />

1400 SPD6A140LI SPD6B140LI SHPD6A140LI SHPD6B140LI<br />

1600 SPD6A160LI SPD6B160LI SHPD6A160LI SHPD6B160LI<br />

1400 SPD6A140LIG SPD6B140LIG SHPD6A140LIG SHPD6B140LIG<br />

1600 SPD6A160LIG SPD6B160LIG SHPD6A160LIG SHPD6B160LIG<br />

1400 SPD6A140LSI SPD6B140LSI SHPD6A140LSI SHPD6B140LSI<br />

1600 SPD6A160LSI SPD6B160LSI SHPD6A160LSI SHPD6B160LSI<br />

1400 SPD6A140LSIG SPD6B140LSIG SHPD6A140LSIG SHPD6B140LSIG<br />

1600 SPD6A160LSIG SPD6B160LSIG SHPD6A160LSIG SHPD6B160LSIG<br />

Trip Unit Adjustable Functions<br />

No. of<br />

cables<br />

per connector<br />

Suffix<br />

Letter<br />

Code<br />

Trip<br />

Type<br />

Cont<br />

Current<br />

Setting<br />

Long<br />

Time<br />

Delay<br />

Instantaneous<br />

Pick Up<br />

LI LI u u u<br />

Short<br />

Time<br />

Pick Up<br />

Short<br />

Time<br />

Fixed<br />

Delay<br />

Short<br />

Time<br />

l 2 t<br />

Delay<br />

Ground<br />

Fault<br />

Pick Up<br />

LIG LIG u u u u u<br />

LSI LSI u u u u u u<br />

LSIG LSIG u u u u u u u u<br />

Interrupting<br />

Ratings<br />

Breaker RMS Symmetrical kA UL 489<br />

Type<br />

240V AC 480V AC 600V AC<br />

SPD6-B 65 50 25<br />

SHPD6-B 100 65 50<br />

Mounting Block<br />

(Required) b<br />

Catalog Number<br />

MB9301<br />

MBR9302<br />

Ground<br />

Fault<br />

Delay<br />

Ordering Information<br />

Pricing information for all Digital<br />

Sentron Series PD frame unit is<br />

for breaker only. Price required<br />

mounting block assembly and<br />

necessary terminal connectors<br />

as separate items.<br />

SPD6-B and SHPD6-B are<br />

acceptable for reverse connection<br />

applications.<br />

Lugs a<br />

Catalog<br />

Number<br />

Wire<br />

Range<br />

TA5P600 1-5 pcs. 300-600 kcmil Cu/Al<br />

TC5R600 1-5 pcs. 300-600 kcmil Cu Only<br />

TA6R600 1-6 pcs. 300-600 kcmil Cu/Al<br />

Neutral Transformers<br />

Ampere Rating Catalog Number<br />

1400 N14SPD<br />

1600 N16SPD<br />

Enclosure<br />

Type<br />

Catalog Number<br />

1 PRD6N1<br />

7<br />

All PD, RD Frames:<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

MB9301 (shown)<br />

MBR9302<br />

MBR9302 MB9301 MBR9302<br />

MB9301<br />

For inches / millimeters conversion, see Application Data section.<br />

Note: “G” suffix in catalog number denotes circuit<br />

breaker for 3-phase, 3-wire circuits.<br />

For 3-phase, 4-wire, order correct 4th wire (neutral)<br />

transformer as separate and additional item.<br />

All breakers built to order. Allow 2–3 weeks for delivery.<br />

a For additional information, see Note: A, page 7-153.<br />

b The PD frame circuit breaker requires the use of a<br />

connect-all mounting assembly to allow for placing<br />

into service.<br />

c Advanced trip unit equipped with DAS / Maintenance<br />

Mode. Requires customer-supplied 24V external power<br />

supply, maintenance switch and light.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-137


Molded Case Circuit Breakers<br />

Internal Accessories<br />

Revised on 08/31/20<br />

Selection<br />

Accessories for:<br />

MD/SMD 800A Frame<br />

ND/SND 1200A Frame<br />

PD/SPD 1600A Frame<br />

RD 2000A Frame<br />

Shunt Trip Combinations<br />

Control Voltage 1 Shunt Trip<br />

1 Shunt Trip and<br />

1 Auxiliary Switch<br />

AC DC Catalog Number Catalog Number<br />

120 S01MN6 S01MN64A<br />

208 S02MN6s —<br />

240 S03MN6 S03MN64As<br />

277 S15MN6s S15MN64As<br />

480 S04MN6s S04MN64As<br />

600 S06MN6s —<br />

012 S16MN6s S16MN64As<br />

024 S07MN6 S07MN64A<br />

048 S09MN6s —<br />

125 S11MN6 S11MN64As<br />

250 S13MN6s S13MN64As<br />

Undervoltage Trip Combinations<br />

Control Voltage<br />

1 Undervoltage Trip<br />

1 Undervoltage Trip and<br />

1 Auxiliary Switch<br />

1 Undervoltage Trip and<br />

2 Auxiliary Switches<br />

S01MN6<br />

Accessory modules can mount in either<br />

left hand or right hand poles of all circuit<br />

breakers, including solid state. Exception:<br />

when mechanical interlock is used.<br />

Accessories cannot be mounted in left<br />

pole.<br />

AC DC Catalog Number Catalog Number Catalog Number<br />

120 U01MN6 U01MN64A U01MN64AA<br />

208 U02MN6s U02MN64As U02MN64AAs<br />

240 U03MN6s U03MN64As U03MN64AAs<br />

277 U15MN6s U15MN64As U15MN64AAs<br />

480 U04MN6s U04MN64As U04MN64AAs<br />

600 U06MN6s — —<br />

024 U07MN6 U07MN64A U07MN64AA<br />

048 U09MN6s U09MN64As U09MN64AAs<br />

125 U11MN6s U11MN64As U11MN64AAs<br />

7<br />

Auxiliary Switch Combinations<br />

Maximum<br />

Voltage 1 Form C 2 Form C<br />

AC DC Catalog Number Catalog Number<br />

480 250 A01MN64 A02MN64<br />

— 24 A01MNDLVs A02MNDLVs<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Alarm Switch Combinations<br />

Maximum<br />

Voltage<br />

1 Alarm Switch<br />

1 Alarm Switch and<br />

1 Auxiliary Switch<br />

1 Alarm Switch and<br />

2 Auxiliary Switches<br />

AC DC Catalog Number Catalog Number Catalog Number<br />

480 250 B00MN64 A01MN64B A02MN64B<br />

ETU Testing Unit<br />

Breaker Type Description Catalog Number<br />

SJD, SLD, SMD, Power Stick<br />

EPSP18V<br />

SND, SPD<br />

Spare cable for Power Stick COMPCA<br />

The EPSP18V Power Stick is a hand-held, battery-operated power supply<br />

that can be used for trip testing the Sensitrip IV electronic trip units.<br />

Requires two 9V batteries.<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

7-138<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

RD 2000A Frame Sentron Series<br />

Selection<br />

Type RXD6 d<br />

3-Pole 600V AC, 250-500V DC a<br />

Blue Label<br />

Non-Interchangeable Trip (Assembled Circuit Breaker Only Without Lugs)<br />

Continuous<br />

Current<br />

Rating @ 40°C<br />

Complete Breaker Assembled<br />

(Frame/Trip Unit Only) Mounting Assembly Lugs (6 required)<br />

Catalog Number Catalog Number Catalog Number<br />

1600 RXD63B160 MB9301<br />

1800 RXD63B180 -or- TC5R600<br />

2000 RXD63B200 MBR9302<br />

Type RD6 d<br />

3-Pole 600V AC, 250-500V DC a<br />

Interchangeable Trip (Unassembled Circuit Breaker with Lugs)<br />

Continuous Complete Breaker<br />

Mounting<br />

Current Unassembled Frame Only Trip Unit Only Assembly<br />

Rating @ Catalog<br />

Catalog Catalog Catalog<br />

40°C Number<br />

Number Number Number<br />

Type HRXD6 d<br />

Interrupting Ratings<br />

UL 489 A IR<br />

RMS Symmetrical KA<br />

Breaker<br />

Volts AC<br />

Volts DC a<br />

Type 240 480 600 250 500<br />

RD6, RXD6 65 50 25 30 (2P) 25 (3P)<br />

HRD6, HRXD6 100 65 50 30 (2P) 50 (3P)<br />

Blue Label<br />

Lugs (6 required)<br />

Catalog<br />

Number<br />

1600 RD63B160n RD63T160n MB9301<br />

1800 RD63B180 RD63F200 RD63T180 -or- TC5R600<br />

2000 RD63B200 RD63T200 MBR9302<br />

Black Label<br />

Continuous Current<br />

Rating @ 40°C<br />

Complete Breaker Assembled (Frame/Trip Unit Only)<br />

Catalog Number<br />

1600 HRXD63B160n<br />

1800 HRXD63B180n<br />

2000 HRXD63B200<br />

Type HRD6 d<br />

Continuous<br />

Current<br />

Rating @<br />

40°C<br />

Complete Breaker<br />

Unassembled Frame Only Trip Unit Only<br />

Catalog<br />

Catalog Catalog<br />

Number<br />

Number Number<br />

Mounting<br />

Assembly<br />

Catalog<br />

Number<br />

Black Label<br />

Lugs (6 required)<br />

Catalog<br />

Number<br />

1600 HRD63B160n RD63T160n MB9301<br />

1800 HRD63B180 HRD63F200 RD63T180 -or- TC5R600<br />

2000 HRD63B200 RD63T200 MBR9302<br />

Mounting Block <br />

Catalog<br />

Number<br />

MB9301<br />

MBR9302<br />

RXD63B200<br />

Shipping Weights<br />

Connection Points<br />

Front<br />

Rear<br />

Number of Number per Shipping<br />

Poles Carton Weight (lbs.)<br />

PXD6, HPXD6, RXD6, HRXD6, CPD6<br />

Assembled Breakers<br />

3 1 61.5<br />

PD6, HPD6, RD6, HRD6<br />

Frame Only<br />

3 1 55.0<br />

PD6, RD6<br />

Trip Unit Only<br />

3 1 06.5<br />

Mounting Assembly<br />

MB9301 1 53.0<br />

MBR9302 1 50.9<br />

Lugs (6 required per breaker) e<br />

No of<br />

Catalog Cables per<br />

Number Connector Wire Range<br />

TC5R600 1-5 300-600 kcmil Cu only<br />

TA6R600 1-6 300-600 kcmil Cu/Al<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Instantaneous Adjustment Trip Range (PD / RD Frames)<br />

Nominal Instantaneous Values<br />

+20% +20%<br />

Breaker Ampere Tolerance Tolerance<br />

Rating Low 2 3 4 5 6 7 High<br />

1200-2000 5000 5715 6430 7145 7860 8575 9790 10,000<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

a Use two outside poles of a 3-pole circuit breaker for<br />

250V DC applications.<br />

b When wired as shown on page 7-4, this circuit breaker is<br />

UL listed and rated for use on 500V DC ungrounded<br />

UPS systems only.<br />

c RXD6 and HRXD6 type circuit breakers are UL Listed for<br />

reverse feed applications.<br />

d HACR rated.<br />

e For additional information See Note: A, page 7-153.<br />

Note: RD frame qualified to UL489 supplement B “NAVAL”.<br />

See page 7-156 for additional information.<br />

For required mounting base (MB9301 or MBR9302) see<br />

page 7-137.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-139


Molded Case Circuit Breakers<br />

Magnetic Trip Only — ETI Motor Circuit Protector<br />

Revised on 02/28/19<br />

Selection<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Breaker<br />

Type<br />

ED6-A<br />

600V AC<br />

250V DC<br />

CED6-A<br />

600V AC<br />

250V DC<br />

FXD6 d<br />

600V AC<br />

250V DC<br />

CFD6 d<br />

600V AC<br />

250V DC<br />

JXD6(A) a<br />

600V AC<br />

250V DC<br />

CJD6 a<br />

600V AC<br />

250V DC<br />

LXD6(A) a<br />

600V AC<br />

250V DC<br />

CLD6 a<br />

600V AC<br />

250V DC<br />

LMXD6 d<br />

600V AC<br />

250V DC<br />

MXD6 d<br />

600V AC<br />

250V DC<br />

CMD6 d<br />

600V AC<br />

250V DC<br />

Ampere<br />

Rating<br />

Instantaneous Trip Range b<br />

Minimum c Maximum c 2-Pole<br />

Catalog Number<br />

Complete Circuit Breaker Without Lugs e<br />

Catalog Number<br />

3-Pole<br />

001 002.6 00009 — ED63A001<br />

002 007 00022 — ED63A002<br />

003 010 00035 — ED63A003<br />

005 016 00054 — ED63A005<br />

010 030 00100 — ED63A010<br />

025 055 00180 — ED63A025<br />

030 080 00270 — ED63A030<br />

040 115 00375 — ED63A040<br />

050 180 00600 — ED63A050<br />

100 315 01000 — ED63A100<br />

125 500 01250 — ED63A125<br />

SHIPPING:<br />

03.8 lbs. each<br />

001 002.6 00009 — CED63A001n<br />

002 007 00022 — CED63A002n<br />

003 010 00035 — CED63A003n<br />

005 016 00054 — CED63A005n<br />

010 030 00100 — CED63A010n<br />

025 055 00180 — CED63A025n<br />

030 080 00270 — CED63A030n<br />

040 115 00375 — CED63A040n<br />

050 180 00600 — CED63A050n<br />

100 315 01000 — CED63A100n<br />

125 500 01250 — CED63A125n<br />

SHIPPING:<br />

06 lbs. each<br />

150 0400 00800 — FXD63L150n<br />

150 0800 01500 — FXD63A150<br />

150 1100 02500 — FXD63H150<br />

250 1100 02500 — FXD63A250<br />

SHIPPING:<br />

09 lbs. each<br />

150 0400 00800 — CFD63L150n<br />

150 0800 01500 — CFD63A150n<br />

150 1100 02500 — CFD63H150n<br />

250 1100 02500 — CFD63A250n<br />

SHIPPING: 12 lbs. each 12 lbs. each<br />

400 1250 02500 — JXD63L400<br />

400 2000 04000 JXD62H400n JXD63H400<br />

SHIPPING: 16 lbs. each 20 lbs. each<br />

400 1250 02500 — CJD63L400n<br />

400 2000 04000 — CJD63H400n<br />

SHIPPING: 29.5 lbs. each 31.5 lbs. each<br />

600 2000 04000 LXD62L600n LXD63L600n<br />

600 3000 06000 — LXD63H600<br />

SHIPPING: 16 lbs. each 20 lbs. each<br />

600 2000 04000 — CLD63L600n<br />

600 3000 06000 — CLD63H600n<br />

SHIPPING:<br />

31.5 lbs. each<br />

800 2800 06000 — LMXD63L800n<br />

800 3200 08000 — LMXD63A800<br />

SHIPPING:<br />

35 lbs. each<br />

800 3000 06000 — MXD63L800n<br />

800 4000 08000 — MXD63A800n<br />

800 5000 10000 — MXD63H800<br />

SHIPPING:<br />

33 lbs. each<br />

800 3000 06000 — CMD63L800n<br />

800 4000 08000 — CMD63A800n<br />

800 5000 10000 — CMD63H800n<br />

SHIPPING:<br />

80 lbs. each<br />

Important Information<br />

ETI interrupting ratings are determined through combination tests with properly sized overload relays and contactors.<br />

e Connectors included when ordering by circuit breaker catalog number for HEM, ED and CED6 ETIs. Order ETI<br />

circuit breaker and lugs (2 per pole) separately for the FXD6, CFD6, MXD6, CMD6, JXD6, CJD6, LXD6 and CLD6 ETI’s.<br />

Lug Information pages 7-153 to 7-155<br />

Enclosures Section 6<br />

Accessories pages 7-160 to 7-165<br />

Application data pages 7-141 to 7-142<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

a 2-pole available in 3-pole width only.<br />

b When applied on DC Circuits — Trip levels will increase<br />

approximately + 15 to 20%.<br />

c Tolerance -20%/+30% for lowest setting. All other settings<br />

are -20%/+20%<br />

d For 2-pole application use outside poles of 3-pole circuit<br />

breaker.<br />

7-140<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

Motor Circuits<br />

Revised on 02/28/19<br />

Application<br />

General<br />

Protection of Motor Circuits<br />

Molded case circuit breakers are used in<br />

motor circuits as a disconnecting means<br />

and for short-circuit protection. They<br />

should be used in conjunction with<br />

motor-running, over-current-protection<br />

devices, and should permit the motor<br />

to start without nuisance tripping from<br />

motor-inrush current. The circuit breaker<br />

should have a continuous-current rating<br />

of not less than 115% of the motor<br />

full-load current.<br />

The recommended motor circuit<br />

protectors (Siemens ETI instantaneous<br />

only circuit breakers) listed have<br />

continuous-current ratings of at least<br />

115% of motor full-load currents. The<br />

trip-setting positions are approximately<br />

11 times motor full-load currents. The<br />

suggested trip settings may have to be<br />

adjusted upward to no higher than 1300%<br />

of full-load current for non-design E type<br />

motors, and no greater than 1700% of full<br />

load current for design E motors, to allow<br />

for motor start-up due to inrush currents.<br />

Breaker Mounted Immediately Ahead<br />

of Motor Starter<br />

Siemens ETI motor circuit protectors are<br />

recommended for use in combination<br />

motor starters to provide selective<br />

short-circuit protection for the motor<br />

branch circuit. The adjustable<br />

instantaneous-trip feature of the Siemens<br />

ETI motor circuit protector provides for a<br />

trip setting slightly above the peak<br />

motor-inrush current. With this setting,<br />

no delay is introduced in opening the<br />

circuit when a fault occurs. This circuit<br />

breaker has no time-delay trip element.<br />

Therefore it must be used in conjunction<br />

with, and immediately ahead of, the<br />

motor-running overcurrent protective<br />

device.<br />

Important: The information below does<br />

not apply to all motor applications: it<br />

is recommended that the user refer to<br />

the National Electrical Code (NEC) for<br />

specific needs.<br />

Table 1 (When Breaker is Mounted Immediately Ahead of Motor Starter)<br />

3-Phase Induction Type Motors (Siemens ETI motor circuit protectors for branch circuit use with alternating-current combination, full voltage motor starters).<br />

Motor<br />

ETI Trip Setting<br />

Full Load Catalog Adjust-<br />

Amperes Number ment Amperes<br />

.20 – .33 Low 2.6<br />

.34 – .45 2 4.5<br />

.46 – .56 ED63A001 3 6<br />

.57 – .68 CED63A001 4 7.5<br />

.69 – .81 High 9<br />

.53 – .83 Low 7<br />

.84 – 1.14 2 11<br />

1.15 – 1.45 ED63A002 3 15<br />

1.46 – 1.68 CED63A002 4 19<br />

1.69 – 2.00 High 22<br />

.76 – 1.29 Low 10<br />

1.30 – 1.75 2 17<br />

1.76 – 2.29 ED63A003 3 23<br />

2.30 – 2.68 CED63A003 4 30<br />

2.69 – 3.18 High 35<br />

1.23 – 1.99 Low 16<br />

2.00 – 2.75 2 26<br />

2.76 – 3.52 ED63A005 3 36<br />

3.53 – 4.14 CED63A005 4 46<br />

4.15 – 4.90 High 54<br />

2.30 – 3.83 Low 30<br />

3.84 – 5.37 2 50<br />

5.38 – 6.52 ED63A010 3 70<br />

6.53 – 7.68 CED63A010 4 85<br />

7.69 – 9.10 High 100<br />

4.23 – 6.91 Low 55<br />

6.92 – 9.61 2 90<br />

9.62 – 11.91 ED63A025 3 125<br />

11.92 – 13.83 CED63A025 4 155<br />

13.84 – 16.40 High 180<br />

6.15 – 10.37 Low 80<br />

10.38 – 14.22 2 135<br />

14.23 – 18.06 ED63A030 3 185<br />

18.07 – 20.75 CED63A030 4 235<br />

20.76 – 24.50 High 270<br />

ETI Trip Setting<br />

Motor Full Catalog Adjust-<br />

Load Amperes Number ment Amperes<br />

8.84 – 14.22 Low 115<br />

14.23 – 19.60 2 185<br />

19.61 – 24.99 ED63A040 3 255<br />

25.00 – 28.83 CED63A040 4 325<br />

28.84 – 34.00 High 375<br />

13.84 – 23.06 Low 180<br />

23.07 – 31.52 2 300<br />

31.53 – 39.99 ED63A050 3 410<br />

40.00 – 46.14 CED63A050 4 520<br />

46.15 – 54.50 High 600<br />

24.23 – 41.52 Low 315<br />

41.53 – 56.91 2 540<br />

56.92 – 68.45 ED63A100 3 740<br />

68.46 – 76.91 CED63A100 4 890<br />

76.92 – 90.90 High 1000<br />

38.46 – 55.37 Low 500<br />

55.38 – 70.75 2 720<br />

70.76 – 84.60 ED63A125 3 920<br />

84.61 – 96.14 CED63A125 4 1100<br />

96.15 – 113.60 High 1250<br />

30.76 – 35.37 Low 400<br />

35.38 – 39.99 2 460<br />

44.51 – 49.23 FXD63L150 4 580<br />

53.84 – 58.45 CFD63L150 6 700<br />

58.46 – 63.06 7 760<br />

63.07 – 74.50 High 820<br />

61.53 – 69.22 Low 800<br />

69.23 – 76.91 2 900<br />

84.61 – 92.29 FXD63A150 4 1100<br />

100.00 – 108.00 CFD63A150 6 1300<br />

108.00 – 115.00 7 1400<br />

115.00 – 136.00 High 1500<br />

85.00 – 100.00 Low 1100<br />

100.00 – 115.00 2 1300<br />

131.00 – 146.00 FXD63A250 4 1700<br />

162.00 – 177.00 CFD63A250 6 2100<br />

177.00 – 192.00 7 2300<br />

192.00 – 227.00 High 2500<br />

ETI Trip Setting<br />

Motor Full Catalog Adjust-<br />

Load Amperes Number ment Amperes<br />

95.00 – 110.00 Low 1250<br />

110.00 – 124.00 2 1430<br />

138.00 – 151.00 JXD63L400 4 1790<br />

165.00 – 178.00 CJD63L400 6 2140<br />

178.00 – 192.00 7 2320<br />

192.00 – 227.00 High 2500<br />

154.00 – 176.00 Low 2000<br />

176.00 – 198.00 2 2290<br />

220.00 – 242.00 JXD63H400 4 2860<br />

264.00 – 285.00 CJD63H400 6 3430<br />

285.00 – 308.00 7 3710<br />

308.00 – 326.00 High 4000<br />

155.00 – 176.00 Low 2000<br />

176.00 – 198.00 2 2290<br />

220.00 – 242.00 LXD63L600 4 2860<br />

264.00 – 285.00 CLD63L600 6 3430<br />

285.00 – 308.00 7 3710<br />

308.00 – 326.00 High 4000<br />

231.00 – 264.00 Low 3000<br />

264.00 – 292.00 2 3430<br />

330.00 – 362.00 LXD63H600 4 4290<br />

395.00 – 428.00 CLD63H600 6 5140<br />

428.99 – 462.00 7 5570<br />

462.00 – 490.00 High 6000<br />

215.00 – 238.00 Low 2800<br />

238.00 – 261.00 2 3100<br />

261.00 – 284.00 3 3400<br />

308.00 – 369.00 LMXD63L800 5 4000<br />

369.00 – 423.00 6 4800<br />

423.00 – 462.00 7 5500<br />

462.00 – 490.00 High 6000<br />

246.00 – 269.00 Low 3200<br />

269.00 – 284.00 2 3500<br />

284.00 – 323.00 3 3700<br />

362.00 – 492.00 LMXD63A800 5 4700<br />

492.00 – 562.00 6 6400<br />

562.00 – 616.00 7 7300<br />

616.00 – 660.00 High 8000<br />

231.00 – 264.00 Low 3000<br />

264.00 – 292.00 2 3430<br />

292.00 – 330.00 3 3800<br />

362.00 – 395.00 MXD63L800 5 4710<br />

428.00 – 462.00 CMD63L800 7 5570<br />

462.00 – 490.00 High 6000<br />

308.00 – 352.00 Low 4000<br />

352.00 – 442.00 2 4570<br />

442.00 – 447.00 3 5740<br />

483.00 – 527.00 MXD63A800 5 6280<br />

571.00 – 616.00 CMD63A800 7 7240<br />

616.00 – 660.00 High 8000<br />

385.00 – 440.00 Low 5000<br />

495.00 – 550.00 MXD63H800 3 6430<br />

605.00 – 660.00 CMD63H800 5 7860<br />

660.00 – 695.00 6 8575<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Note: Lowest instantaneous settings have a -20%/+30% tolerance and all<br />

other settings have a -20%/+20% tolerance.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-141


Molded Case Circuit Breakers<br />

Motor Circuits<br />

Breaker Mounted at a Distance From<br />

Motor Starter<br />

ET thermal-magnetic circuit breakers<br />

conform to the National Electrical Code<br />

table 430-52 requirements for motor<br />

branch and feeder circuit protection<br />

when properly applied in conjunction with<br />

motor-running overcurrent protective<br />

devices. The recommended<br />

circuit-breaker ratings in Table 2 provide<br />

adequate time delay for starting the<br />

majority of three phase induction motors.<br />

To determine the ampere ratings of the ET<br />

breaker to protect a motor feeder, add the<br />

rating of the ET breaker used to protect<br />

the largest motor branch circuit in the<br />

group to the full-load currents of the<br />

remaining motors in the group.<br />

Application<br />

Interrupt Ratings<br />

For normal commercial purposes,<br />

available fault current can conveniently<br />

be obtained in the Interrupting<br />

Selector Tables.<br />

Table 2 (When Breaker is Mounted at a Distance From Motor Starter)<br />

3-Phase Induction Type Motors (EQ and ET circuit breakers (thermal-magnetic trip) for branch breaker use with alternating-current combination motor starters).<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

200 and 208V Motors 230V Motors 460V Motors 575V Motors<br />

Motor 240V Circuit Breaker Data<br />

Horse-<br />

240V Circuit Breaker Data a 480V Circuit Breaker Data a 600V Circuit Breaker Data a<br />

power Breaker Catalog Ampere Breaker Catalog Ampere Breaker Catalog Ampere Breaker Catalog Ampere<br />

Rating Type Number Rating Type Number Rating Type Number Rating Type Number Rating<br />

000 1 ⁄2 BQ3B015 015 BQ3B015 015 ED43B015 015 ED63B015 015<br />

000 3 ⁄4 BQ3B015 015 BQ3B015 015 ED43B015 015 ED63B015 015<br />

001<br />

BQ b BQ3B015 015 BQ b BQ3B015 015 ED43B015 015<br />

ED63B015 015<br />

ED4<br />

ED6<br />

001 1 ⁄2 BQ3B015 015 BQ3B015 015 ED43B015 015 ED63B015 015<br />

002 BQ3B020 020 BQ3B015 015 ED43B015 015 ED63B015 015<br />

003 BQ3B030 030 BQ3B020 020 ED43B015 015 ED63B015 015<br />

005 BQ3B040 040 BQ3B030 030 ED43B015 015 ED63B015 015<br />

007 1 ⁄2 BQ3B060 060 BQ3B050 050 ED43B030 030 ED63B020 020<br />

010 BQ b BQ3B070 070 BQ b BQ3B070 070 ED4 ED43B030 030 ED6 ED63B030 030<br />

015 BQ3B100 100 BQ3B090 090 ED43B040 040 ED63B035 035<br />

020 BQ3B100 100 ED43B050 050 ED63B050 050<br />

025 FXD63B125 125 FXD63B125 125 FXD63B090 090 FXD63B060 060<br />

030 FXD63B150 150 FXD63B150 150 FXD63B100 100<br />

FXD6<br />

FXD63B070 070<br />

040 FXD6 FXD63B175 175 FXD6 FXD63B175 175 FXD6 FXD63B125 125 FXD63B090 090<br />

050 FXD63B200 200 FXD63B200 200 FXD63B150 150 FXD63B100 100<br />

FXD63B225 225<br />

060 JXD2 JXD23B300 300 — — — FXD6, FD6 FXD63B150 150 FXD6 FXD63B100 100<br />

075 JXD2 JXD23B400 400 JXD2 JXD23B350 350 FXD6, FD6 FXD63B200 200 FXD6, FD6 FXD63B125 125<br />

100 JXD2 JXD23B400 400 JXD2 JXD23B400 400<br />

FD6 c FD63B250 250<br />

JD6 c JD63B250 250<br />

FXD6, FD6 FD63B175 175<br />

125<br />

LD6 c or LD63B600<br />

600<br />

LD6 c or LD63B500 or<br />

500 JD6 c JD63B300 300<br />

FXD6, FD6 FXD63B200 200<br />

LMD6 LMD63B600 LMD6 LMD63B500 OR JD6 c JD63B200 200<br />

150<br />

LD6 c or LD63B600 or<br />

600 LMD6<br />

LD63B600 or<br />

600 JD6 c JD63B300 300<br />

FXD6 or FXD63B225 225<br />

LMD6 LMD63B600 LMD63B600 JD6 c JD63B225 225<br />

200 LMD6 LMD63B800 800 LMD6 LMD63B800 800 c JD6 JD63B350 350 JD6 c JD63B300 300<br />

250 — — — — — — JD6 c JD63B400 400 JD6 c JD63B400 400<br />

300 — — — — — —<br />

LD6 c or LD63B600 or<br />

LMD6 LMD63B600<br />

600 JD6 c JD63B400 400<br />

350 — — — — — — LMD6 LMD63B700 700<br />

LD6 c or<br />

LMD6<br />

LD63B500 or<br />

LMD63B500<br />

500<br />

400 — — — — — — LMD6 LMD63B800 800<br />

LD6 c or LD63B600 or<br />

LMD6 LMD63B600<br />

600<br />

500 — — — — — — — — — LMD6 LMD63B800 800<br />

aThe selection of breakers for this table is in accordance with<br />

Article 430, 2005 National Electric Code. Recommended<br />

circuit breakers are for full voltage starting, special<br />

consideration is necessary for reduced voltage starting.<br />

bFor panelboard applications, substitute the BL breaker for<br />

the BQ, ED2 circuit breakers may also be used.<br />

cFor non-interchangeable trip applications, substitute the<br />

FXD6 for the FD6, the JXD6 for the JD6, or the LXD6 for<br />

the LD6.<br />

7-142<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Molded Case Circuit Breakers<br />

Adjustable Installments Magnetic Trip Settings<br />

Revised on 02/28/19<br />

Application<br />

Maximum Nominal ETI Motor Circuit Protector Thermal Magnetic<br />

Breaker Continuous AC Adjustable Trip Range Catalog Number Catalog Number<br />

Type Amperes Low 2 3 4 5 6 7 High 3-Pole 2-Pole 3-Pole<br />

1 2.6 4.5 6 7.5 — — — 9 ED63A001 — —<br />

2 7 11 15 19 — — — 22 ED63A002 — —<br />

3 10 17 23 30 — — — 35 ED63A003 — —<br />

5 16 26 36 46 — — — 54 ED63A005 — —<br />

10 30 50 70 85 — — — 100 ED63A010 — —<br />

ED6 25 55 90 125 155 — — — 180 ED63A025 — —<br />

30 80 135 185 235 — — — 270 ED63A030 — —<br />

40 115 185 255 325 — — — 375 ED63A040 — —<br />

50 180 300 410 520 — — — 600 ED63A050 — —<br />

100 315 540 740 890 — — — 1000 ED63A100 — —<br />

125 500 720 920 1100 — — — 1250 ED63A125 — —<br />

1 2.6 4.5 6 7.5 — — — 9 CED63A001n — —<br />

2 7 11 15 19 — — — 22 CED63A002n — —<br />

3 10 17 23 30 — — — 35 CED63A003n — —<br />

5 16 26 36 46 — — — 54 CED63A005n — —<br />

10 30 50 70 85 — — — 100 CED63A010n — —<br />

CED6 25 55 90 125 155 — — — 180 CED63A025n — —<br />

30 80 135 185 235 — — — 270 CED63A030n — —<br />

40 115 185 255 325 — — — 375 CED63A040n — —<br />

50 180 300 410 520 — — — 600 CED63A050 — —<br />

100 315 540 740 890 — — — 1000 CED63A100 — —<br />

125 500 720 920 1100 — — — 1250 CED63A125 — —<br />

70 600 640 690 730 770 810 850 900 — FXD62B070 FXD63B070<br />

80 600 640 690 730 770 810 850 900 — FXD62B080 FXD63B080<br />

90 600 640 690 730 770 810 850 900 — FXD62B090 FXD63B090<br />

100 700 770 840 920 990 1060 1140 1200 — FXD62B100 FXD63B100<br />

110 700 770 840 920 990 1060 1140 1200 — FXD62B110 FXD63B110<br />

125 800 900 1000 1100 1200 1300 1400 1500 — FXD62B125 FXD63B125<br />

FXD6-A<br />

150 400 460 520 580 640 700 760 820 FXD63L150 — —<br />

150 800 900 1000 1100 1200 1300 1400 1500 FXD63A150 FXD62B150 FXD63B150<br />

150 1100 1300 1500 1700 1900 2100 2300 2500 FXD63H150 — —<br />

175 900 1060 1210 1370 1520 1780 1930 2000 — FXD62B175 FXD63B175<br />

200 900 1060 1210 1370 1520 1780 1930 2000 — FXD62B200 FXD63B200<br />

225 1100 1300 1500 1700 1900 2100 2300 2500 — FXD62B225 FXD63B225<br />

250 1100 1300 1500 1700 1900 2100 2300 2500 FXD63A250 FXD62B250 FXD63B250<br />

70 600 640 690 730 770 810 850 900 — FD62B070 FD63B070<br />

80 600 640 690 730 770 810 850 900 — FD62B080 FD63B080<br />

90 600 640 690 730 770 810 850 900 — FD62B090 FD63B090<br />

100 700 770 840 920 990 1060 1140 1200 — FD62B100 FD63B100<br />

110 700 770 840 920 990 1060 1140 1200 — FD62B110 FD63B110<br />

FD6-A 125 800 900 1000 1100 1200 1300 1400 1500 — FD62B125 FD63B125<br />

150 800 900 1000 1100 1200 1300 1400 1500 — FD62B150 FD63B150<br />

175 900 1060 1210 1370 1520 1780 1930 2000 — FD62B175 FD63B175<br />

200 900 1060 1210 1370 1520 1780 1930 2000 — FD62B200 FD63B200<br />

225 1100 1300 1500 1700 1900 2100 2300 2500 — FD62B225 FD63B225<br />

250 1100 1300 1500 1700 1900 2100 2300 2500 — FD62B250 FD63B250<br />

70 600 640 690 730 770 810 850 900 — HFD62B070 HFD63B070<br />

80 600 640 690 730 770 810 850 900 — HFD62B080 HFD63B080<br />

90 600 640 690 730 770 810 850 900 — HFD62B090 HFD63B090<br />

100 700 770 840 920 990 1060 1140 1200 — HFD62B100 HFD63B100<br />

110 700 770 840 920 990 1060 1140 1200 — HFD62B110 HFD63B110<br />

HFD6 125 800 900 1000 1100 1200 1300 1400 1500 — HFD62B125 HFD63B125<br />

150 800 900 1000 1100 1200 1300 1400 1500 — HFD62B150 HFD63B150<br />

175 900 1060 1210 1370 1520 1780 1930 2000 — HFD62B175 HFD63B175<br />

200 900 1060 1210 1370 1520 1780 1930 2000 — HFD62B200 HFD63B200<br />

225 1100 1300 1500 1700 1900 2100 2300 2500 — HFD62B225 HFD63B225<br />

250 1100 1300 1500 1700 1900 2100 2300 2500 — HFD62B250 HFD63B250<br />

70 600 640 690 730 770 810 850 900 — — HHFD63B070<br />

80 600 640 690 730 770 810 850 900 — — HHFD63B080<br />

90 600 640 690 730 770 810 850 900 — — HHFD63B090<br />

100 700 770 840 920 990 1060 1140 1200 — — HHFD63B100<br />

110 700 770 840 920 990 1060 1140 1200 — — HHFD63B110<br />

HHFD6 125 800 900 1000 1100 1200 1300 1400 1500 — — HHFD63B125<br />

150 800 900 1000 1100 1200 1300 1400 1500 — — HHFD63B150<br />

175 900 1060 1210 1370 1520 1780 1930 2000 — — HHFD63B175<br />

200 900 1060 1210 1370 1520 1780 1930 2000 — — HHFD63B200<br />

225 1100 1300 1500 1700 1900 2100 2300 2500 — — HHFD63B225<br />

250 1100 1300 1500 1700 1900 2100 2300 2500 — — HHFD63B250<br />

70 600 640 690 730 770 810 850 900 — CFD62B070 CFD63B070<br />

80 600 640 690 730 770 810 850 900 — CFD62B080 CFD63B080<br />

90 600 640 690 730 770 810 850 900 — CFD62B090 CFD63B090<br />

100 700 770 840 920 990 1060 1140 1200 — CFD62B100 CFD63B100<br />

110 700 770 840 920 990 1060 1140 1200 — CFD62B110 CFD63B110<br />

125 800 900 1000 1100 1200 1300 1400 1500 — CFD62B125 CFD63B125<br />

CFD6 150 400 460 520 580 640 700 760 820 CFD63L150 — —<br />

150 800 900 1000 1100 1200 1300 1400 1500 CFD63A150 CFD62B150 CFD63B150<br />

150 1100 1300 1500 1700 1900 2100 2300 2500 CFD63H150 — —<br />

175 900 1060 1210 1370 1520 1780 1930 2000 — CFD62B175 CFD63B175<br />

200 900 1060 1210 1370 1520 1780 1930 2000 — CFD62B200 CFD63B200<br />

225 1100 1300 1500 1700 1900 2100 2300 2500 — CFD62B225 CFD63B225<br />

250 1100 1300 1500 1700 1900 2100 2300 2500 CFD63A250 CFD62B250 CFD63B250<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Note: Tolerances for instantaneous trip points meet UL 489<br />

(7.3). Nominal AC instantaneous trip points are given<br />

in the tables. For DC instantaneous trip points, add 15%<br />

to nominal values.<br />

Instantaneous trip adjustment is made through the<br />

breaker cover on all frame breakers. To change instantaneous<br />

trip point on circuit breaker, depress indicating<br />

knob, then rotate to desired position.<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-143


Molded Case Circuit Breakers<br />

Adjustable Instantaneous Magnetic Trip Settings<br />

Application<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Maximum Nominal ETI Motor Circuit Protector Thermal Magnetic<br />

Breaker Continuous AC Adjustable Trip Range Catalog Number Catalog Number<br />

Type Amperes Low 2 3 4 5 6 7 High 3-Pole 2-Pole 3-Pole<br />

200 1250 1430 1610 1790 1960 2140 2320 2500 — JXD22B200 JXD23B200<br />

225 1250 1430 1610 1790 1960 2140 2320 2500 — JXD22B225 JXD23B225<br />

JXD2(A)<br />

250 1250 1430 1610 1790 1960 2140 2320 2500 — JXD22B250 JXD23B250<br />

300 1250 1430 1610 1790 1960 2140 2320 2500 — JXD22B300 JXD23B300<br />

350 2000 2290 2570 2860 3140 3430 3710 4000 — JXD22B350 JXD23B350<br />

400 2000 2290 2570 2860 3140 3430 3710 4000 — JXD22B400 JXD23B400<br />

200 1250 1430 1610 1790 1960 2140 2320 2500 — JXD62B200 JXD63B200<br />

225 1250 1430 1610 1790 1960 2140 2320 2500 — JXD62B225 JXD63B225<br />

JXD6(A)<br />

250 1250 1430 1610 1790 1960 2140 2320 2500 — JXD62B250 JXD63B250<br />

300 1250 1430 1610 1790 1960 2140 2320 2500 — JXD62B300 JXD62B300<br />

350 2000 2290 2570 2860 3140 3430 3710 4000 — JXD62B350 JXD23B350<br />

400 2000 2290 2570 2860 3140 3430 3710 4000 — JXD62B400 JXD23B400<br />

200 1250 1430 1610 1790 1960 2140 2320 2500 — JD62B200 JD63B200<br />

225 1250 1430 1610 1790 1960 2140 2320 2500 — JD62B225 JD63B225<br />

250 1250 1430 1610 1790 1960 2140 2320 2500 — JD62B250 JD63B250<br />

JD6(A) 300 1250 1430 1610 1790 1960 2140 2320 2500 — JD62B300 JD63B300<br />

350 2000 2290 2570 2860 3140 3430 3710 4000 — JD62B350 JD63B350<br />

400 1250 1430 1610 1790 1960 2140 2320 2500 JXD63L400 — —<br />

400 2000 2290 2570 2860 3140 3430 3710 4000 JXD63H400 JD62B400 JD63B400<br />

200 1250 1430 1610 1790 1960 2140 2320 2500 — HJD62B200 HJD63B200<br />

225 1250 1430 1610 1790 1960 2140 2320 2500 — HJD62B225 HJD63B225<br />

HJD6(A) 250 1250 1430 1610 1790 1960 2140 2320 2500 — HJD62B250 HJD63H250<br />

300 1250 1430 1610 1790 1960 2140 2320 2500 — HJD62B300 HJD63B300<br />

350 2000 2290 2570 2860 3140 3430 3710 4000 — HJD62B350 HJD63B350<br />

400 2000 2290 2570 2860 3140 3430 3710 4000 — HJD62H400 HJD63B400<br />

200 1250 1430 1610 1790 1960 2140 2320 2500 — HHJD62B200 HHJD63B200<br />

225 1250 1430 1610 1790 1960 2140 2320 2500 — HHJD62B225 HHJD63B225<br />

HHJD6 250 1250 1430 1610 1790 1960 2140 2320 2500 — HHJD62B250 HHJD63B250<br />

300 1250 1430 1610 1790 1960 2140 2320 2500 — HHJD62B300 HHJD63B300<br />

350 2000 2290 2570 2860 3140 3430 3710 4000 — HHJD62B350 HHJD63B350<br />

400 2000 2290 2570 2860 3140 3430 3710 4000 — HHJD62B400 HHJD63B400<br />

200 1250 1430 1610 1790 1960 2140 2320 2500 — — CJD63B200<br />

225 1250 1430 1610 1790 1960 2140 2320 2500 — — CJD63B225<br />

250 1250 1430 1610 1790 1960 2140 2320 2500 — — CJD63B250<br />

CJD6 300 1250 1430 1610 1790 1960 2140 2320 2500 — — CJD63B300<br />

350 2000 2290 2570 2860 3140 3430 3710 4000 — — CJD63B350<br />

400 2000 2290 2570 2860 3140 3430 3710 4000 CJD63H400 — CJD63B400<br />

400 1250 1450 1610 1790 1960 2140 2320 2500 CJD63L400 — —<br />

450 2000 2290 2570 2860 3140 3430 3710 4000 — LXD62B450 LXD63B450<br />

LXD6(A) 500 3000 3430 3860 4290 4710 5140 5570 6000 — LXD62B500 LXD63B500<br />

600 3000 3430 3860 4290 4710 5140 5570 6000 — LXD62B600 LXD63B600<br />

250 1250 1430 1610 1790 1960 2140 2320 2500 — LD62B250 LD63B250<br />

300 1250 1430 1610 1790 1960 2140 2320 2500 — LD62B300 LD63B300<br />

350 2000 2290 2570 2860 3140 3430 3710 4000 — LD62B350 LD63B350<br />

LD6(A) 400 2000 2290 2570 2860 3140 3430 3710 4000 — LD62B400 LD63B400<br />

450 2000 2290 2570 2860 3140 3430 3710 4000 — LD62B450 LD63B450<br />

500 3000 3430 3800 4290 4710 5140 5570 6000 — LD62B500 LD63B500<br />

600 2000 2290 2570 2860 3140 3430 3710 4000 LXD63L600 — —<br />

600 3000 3430 3800 4290 4710 5140 5570 6000 LXD63H600 LD62B600 LD63B600<br />

250 1250 1430 1610 1790 1960 2140 2320 2500 — HLD62B250 HLD63B250<br />

300 1250 1430 1610 1790 1960 2140 2320 2500 — HLD62B300 HLD63B300<br />

350 2000 2290 2570 2860 3140 3430 3710 4000 — HLD62B350 HLD63B350<br />

HLD6(A) 400 2000 2290 2570 2860 3140 3430 3710 4000 — HLD62B400 HLD63B400<br />

450 2000 2290 2570 2860 3140 3430 3710 4000 — HLD62B450 HLD63B450<br />

500 3000 3430 3860 4290 4710 5140 5570 6000 — HLD62B500 HLD63B500<br />

600 3000 3430 3860 4290 4710 5140 5570 6000 — HLD62B600 HLD63B600<br />

250 1250 1430 1610 1790 1960 2140 2320 2500 — HHLD62B250 HHLD63B250<br />

300 1250 1430 1610 1790 1960 2140 2320 2500 — HHLD62B300 HHLD63B300<br />

350 2000 2290 2570 2860 3140 3430 3710 4000 — HHLD62B350 HHLD63B350<br />

HHLD6 400 2000 2290 2570 2860 3140 3430 3710 4000 — HHLD62B400 HHLD63B400<br />

450 2000 2290 2570 2860 3140 3430 3710 4000 — HHLD62B450 HHLD63B450<br />

500 3000 3430 3860 4290 4710 5140 5570 6000 — HHLD62B500 HHLD63B500<br />

600 3000 3430 3860 4290 4710 5140 5570 6000 — HHLD62B600 HHLD63B600<br />

250 1250 1430 1610 1790 1960 2140 2320 2500 — — CJD63B250<br />

300 1250 1430 1610 1790 1960 2140 2320 2500 — — CJD63B300<br />

350 2000 2290 2570 2860 3140 3430 3710 4000 — — CJD63B350<br />

CLD6<br />

400 2000 2290 2570 2860 3140 3430 3710 4000 — — CLD63B400<br />

450 2000 2290 2570 2860 3140 3430 3710 4000 — — CLD63B450<br />

500 3000 3430 3860 4290 4710 5140 5570 6000 — — CLD63B500<br />

600 2000 2290 2570 2860 3140 3430 3710 4000 CLD63L600 — —<br />

600 3000 3430 3860 4290 4710 5140 5570 6000 CLD63H600 — CLD63B600<br />

500 3000 3430 3860 4290 4710 5140 5570 6000 — — LMXD63B500<br />

600 3000 3430 3860 4290 4710 5140 5570 6000 — LMXD62B600 LMXD63B600<br />

LMXD6 700 3200 3500 3700 4200 4700 6400 7300 8000 — LMXD62B700 LMXD63B700<br />

800 2800 3100 3400 3700 4000 4800 5500 6000 LMXD63L800 — —<br />

800 3200 3500 3700 4200 4700 6400 7300 8000 LMXD63A800 LMXD62B800 LMXD63B800<br />

500 3000 3430 3860 4290 4710 5140 5570 6000 — LMD62B500 LMD63B500<br />

600 3000 3430 3860 4290 4710 5140 5570 6000 — LMD62B600 LMD63B600<br />

LMD6<br />

700 3200 3500 3700 4200 4700 6400 7300 8000 — LMD62B700 LMD63B700<br />

800 3200 3500 3700 4200 4700 6400 7300 8000 — LMD62B800 LMD63B800<br />

7-144<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Molded Case Circuit Breakers<br />

Adjustable Instantaneous Magnetic Trip Settings<br />

Application<br />

Maximum Nominal ETI Motor Circuit Protector Thermal Magnetic<br />

Breaker Continuous AC Adjustable Trip Range Catalog Number Catalog Number<br />

Type Amperes Low 2 3 4 5 6 7 High 3-Pole 2-Pole 3-Pole<br />

500 3000 3430 3860 4290 4710 5140 5570 6000 — — HLMXD63B500<br />

HLMXD6<br />

600 3000 3430 3860 4290 4710 5140 5570 6000 — — HLMXD63B600<br />

700 3200 3500 3700 4200 4700 6400 7300 8000 — — HLMXD63B700<br />

800 3200 3500 3700 4200 4700 6400 7300 8000 — — HLMXD63B800<br />

500 3000 3430 3860 4290 4710 5140 5570 6000 — HLMD62B500 HLMD63B500<br />

HLMD6<br />

600 3000 3430 3860 4290 4710 5140 5570 6000 — HLMD62B600 HLMD63B600<br />

700 3200 3500 3700 4200 4700 6400 7300 8000 — HLMD62B700 HLMD63B700<br />

800 3200 3500 3700 4200 4700 6400 7300 8000 — HLMD62B800 HLMD63B800<br />

500 3000 3430 3860 4290 4710 5140 5570 6000 — MD62B500 MD63B500<br />

600 3000 3430 3860 4290 4710 5140 5570 6000 — MD62B600 MD63B600<br />

MD6<br />

700 4000 4570 5140 5710 6280 6850 7420 8000 — MD62B700 MD63B700<br />

800 3000 3430 3860 4280 4710 5140 5570 6000 MXD63L800 — —<br />

800 4000 4570 5140 5710 6280 6850 7420 8000 MXD63A800 MD62B800 MD63B800<br />

800 5000 5715 6430 7145 7860 8575 9290 10000 MXD63H800 — —<br />

500 3000 3430 3860 4280 4710 5140 5570 6000 — MXD62B500 MXD63B500<br />

600 3000 3430 3860 4280 4710 5140 5570 6000 — MXD62B600 MXD63B600<br />

MXD6<br />

700 4000 4570 5140 5710 6280 6850 7420 8000 — MXD62B700 MXD63B700<br />

800 3000 3430 3860 4280 4710 5140 5570 6000 MXD63L800 — —<br />

800 4000 4570 5140 5710 6280 6850 7420 8000 MXD63A800 MXD62B800 MXD63B800<br />

800 5000 5715 6430 7145 7860 8575 9290 10000 MXD63H800 — —<br />

500 3000 3430 3860 4280 4710 5140 5570 6000 — HMD62B500 HMD63B500<br />

HMD6<br />

600 3000 3430 3860 4280 4710 5140 5570 6000 — HMD62B500 HMD63B600<br />

700 4000 4570 5140 5710 6280 6850 7420 8000 — HMD62B700 HMD63B700<br />

800 4000 4570 5140 5710 6280 6850 7420 8000 — HMD62B800 HMD63B800<br />

500 3000 3430 3860 4280 4710 5140 5570 6000 — — HMXD63B500<br />

HMXD6<br />

600 3000 3430 3860 4280 4710 5140 5570 6000 — — HMXD63B600<br />

700 4000 4570 5140 5710 6280 6850 7420 8000 — — HMXD63B700<br />

800 4000 4570 5140 5710 6280 6850 7420 8000 — — HMXD63B800<br />

400 3000 3430 3860 4280 4710 5140 5570 6000 — —<br />

500 3000 3430 3860 4280 4710 5140 5570 6000 — —<br />

600 3000 3430 3860 4280 4710 5140 5570 6000 — — CMD63B600<br />

CMD6 700 4000 4570 5140 5710 6280 6850 7420 8000 — — CMD63B700<br />

800 3000 3430 3860 4280 4710 5140 5570 6000 CMD63L800 — —<br />

800 4000 4570 5140 5710 6280 6850 7420 8000 CMD63A800 — CMD63B800<br />

800 5000 5715 6430 7145 7860 8575 9290 10000 CMD63H800 — —<br />

800 4000 4570 5140 5710 6280 6850 7420 8000 — ND62B800 ND63B800<br />

ND6<br />

900 5000 5715 6430 7145 7860 8575 9290 10000 — ND62B900 ND63B900<br />

1000 5000 5715 6430 7145 7860 8575 9290 10000 — ND62B100 ND63B100<br />

1200 5000 5715 6430 7145 7860 8575 9290 10000 — ND62B120 ND63B120<br />

900 5000 5715 6430 7145 7860 8575 9290 10000 — NXD62B900 NXD63B900<br />

NXD6 1000 5000 5715 6430 7145 7860 8575 9290 10000 — NXD62B100 NXD63B100<br />

1200 5000 5715 6430 7145 7860 8575 9290 10000 — NXD62B120 NXD63B120<br />

800 4000 4570 5140 5710 6280 6850 7420 8000 — HND62B800 HND63B800<br />

HND6<br />

900 5000 5715 6430 7145 7860 8575 9290 10000 — HND62B900 HND63B900<br />

1000 5000 5715 6430 7145 7860 8575 9290 10000 — HND62B100 HND63B100<br />

1200 5000 5715 6430 7145 7860 8575 9290 10000 — HND62B120 HND63B120<br />

900 5000 5715 6430 7145 7860 8575 9290 10000 — — HNXD63B900<br />

HNXD6 1000 5000 5715 6430 7145 7860 8575 9290 10000 — — HNXD63B100<br />

1200 5000 5715 6430 7145 7860 8575 9290 10000 — — HNXD63B120<br />

800 4000 4570 5140 5710 6280 6850 7420 8000 — — CND63B800<br />

CND6<br />

900 5000 5715 6430 7145 7860 8575 9290 10000 — — CND63B900<br />

1000 5000 5715 6430 7145 7860 8575 9290 10000 — — CND63B100<br />

1200 5000 5715 6430 7145 7860 8575 9290 10000 — — CND63B120<br />

1200 5000 5715 6430 7145 7860 8575 9290 10000 — — PD63B120<br />

PD6 1400 5000 5715 6430 7145 7860 8575 9290 10000 — — PD63B140<br />

1600 5000 5715 6430 7145 7860 8575 9290 10000 — — PD63B160<br />

1200 5000 5715 6430 7145 7860 8575 9290 10000 — — PXD63B120<br />

PXD6 1400 5000 5715 6430 7145 7860 8575 9290 10000 — — PXD63B140<br />

1600 5000 5715 6430 7145 7860 8575 9290 10000 — — PXD63B160<br />

1200 5000 5715 6430 7145 7860 8575 9290 10000 — — HPD63B120<br />

HPD6 1400 5000 5715 6430 7145 7860 8575 9290 10000 — — HPD63B140<br />

1600 5000 5715 6430 7145 7860 8575 9290 10000 — — HPD63B160<br />

1200 5000 5715 6430 7145 7860 8575 9290 10000 — — HPXD63B120<br />

HPXD6 1400 5000 5715 6430 7145 7860 8575 9290 10000 — — HPXD63B140<br />

1600 5000 5715 6430 7145 7860 8575 9290 10000 — — HPXD63B160<br />

1200 5000 5715 6430 7145 7860 8575 9290 10000 — — CPD63B120<br />

CPD6 1400 5000 5715 6430 7145 7860 8575 9290 10000 — — CPD63B140<br />

1600 5000 5715 6430 7145 7860 8575 9290 10000 — — CPD63B160<br />

RD6<br />

1800 5000 5715 6430 7145 7860 8575 9290 10000 — — RD63B180<br />

2000 5000 5715 6430 7145 7860 8575 9290 10000 — — RD63B200<br />

RXD6<br />

1800 5000 5715 6430 7145 7860 8575 9290 10000 — — RXD63B180<br />

2000 5000 5715 6430 7145 7860 8575 9290 10000 — — RXD63B200<br />

HRD6<br />

1800 5000 5715 6430 7145 7860 8575 9290 10000 — — HRD63B180<br />

2000 5000 5715 6430 7145 7860 8575 9290 10000 — — HRD63B200<br />

HRXD6<br />

1800 5000 5715 6430 7145 7860 8575 9290 10000 — — HRXD63B180<br />

2000 5000 5715 6430 7145 7860 8575 9290 10000 — — HRXD63B200<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-145


Molded Case Circuit Breakers<br />

Molded Case Switch — Circuit Disconnect<br />

Maximum<br />

2-Pole<br />

3-Pole<br />

Self-Protective<br />

Frame<br />

Instantaneous<br />

Amp Rating Catalog Number Catalog Number Override±20% c<br />

1100<br />

BQ2S060n BQ3S060n 11000<br />

BQ2S100n BQ3S100n 11000<br />

1125 ED22S100An ED23S100A 11000<br />

ED42S100An ED43S100A 11000<br />

ED42S125An ED43S125A 11000<br />

ED62S100An ED63S100A 11000<br />

— ED63S125A 11000<br />

CED62S100An CED63S100An 11000<br />

CED62S125An CED63S125An 11000<br />

1250 — HQR23S250HA 12000<br />

FXD62S250A FXD63S250A 13200<br />

HFXD62S250An HFXD63S250An 13200<br />

a CFD63S250An 13200<br />

1400 JXD22S400An JXD23S400A 16000<br />

— JXD63S400A 16000<br />

— HJXD63S400An 16000<br />

a<br />

CJD63S400An 16000<br />

1600 — LXD63S600A 16000<br />

— HLXD63S600An 16000<br />

a<br />

CLD63S600An 16000<br />

1800 — LMXD63S800An 18000<br />

— MXD63S800A 18000<br />

a<br />

CMD63S800A 18000<br />

1200 — NXD63S120A 10000<br />

a<br />

CND63S120An 10000<br />

1600<br />

2000<br />

a<br />

a<br />

PXD63S160A e 10000<br />

RXD63S200An e 10000<br />

Revised on 02/28/19<br />

Selection<br />

Ordering Information<br />

Order by catalog number. Switches<br />

include frame and self protective trip<br />

unit only. Order lugs separately from<br />

pages 7-153 to 7-155.<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

7<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

a For 2-pole application use outside poles of 3-pole circuit<br />

breaker.<br />

b For additional lugs see pages 7-153 to 7-155.<br />

c Molded case switches up to R frame contain a self<br />

protecting instantaneous element, which may open<br />

circuit above their override set point.<br />

d UL file E57556 Volume 1, section 2 and<br />

CSA LR 42022-51.<br />

e Requires mounting block MB9301 or MBR9302.<br />

Lugs pages 7-153 to 7-155<br />

Enclosures Section 6<br />

Accessories pages 7-160 to 7-165<br />

7-146<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

Digital Solid State Sentron Sensitrip IV Series<br />

Revised on 05/31/18<br />

Technical<br />

The Sentron Sensitrip IV<br />

circuit breaker is a true RMS<br />

current sensing device. Digital<br />

microprocessor circuitry within the<br />

electronic trip unit provides more<br />

precise control over the circuit<br />

breaker functions. This control<br />

allows circuit coordination flexibility<br />

not available with thermal magnetic<br />

circuit breakers.<br />

Functions available in Sentron Sensitrip circuit breakers<br />

Catalog<br />

Number<br />

Suffix<br />

Trip<br />

Type<br />

Cont<br />

Current<br />

Setting<br />

Long<br />

Time<br />

Delay<br />

LI LI u u u<br />

Instantaneous<br />

Pickup<br />

Short<br />

Time<br />

Pickup<br />

Short<br />

Time<br />

Fixed<br />

Delay<br />

Short<br />

Time<br />

I2t<br />

Delay<br />

Ground<br />

Fault<br />

Pickup<br />

LIG LIG u u u u u<br />

LSI LSI u u u u u u<br />

LSIG LSIG u u u u u u u u<br />

Ground<br />

Fault<br />

Delay<br />

Typical Trip Unit Labeling and Adjustment Positions for the Sentron Sensitrip Circuit Breaker.<br />

LI Trip Units a<br />

LIG Trip Units a<br />

LSI Trip Units a<br />

7<br />

LSIG Trip Units a<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

l n<br />

l r<br />

= Maximum circuit breaker ampere rating<br />

= Continuous current rating expressed in amperes<br />

I i = Instantaneous pickup expressed in amperes<br />

I sd = Short time pickup expressed in multiples of I r<br />

I g = Ground fault pickup expressed in amperes<br />

t sd = Short time delay - either fixed or I 2 t time delay function<br />

t ld = Long time delay - I 2 t time delay function<br />

t g = Ground fault delay - I 2 t time delay function<br />

NOTE: Frame rating (In) of 600A shown as an example.<br />

Trip unit settings will vary based on the specific frame<br />

rating (In) of the device.<br />

a Schematic of advanced trip unit shown. Basic trip units<br />

are identical but do not include DAS / Maintenance<br />

Mode functionality.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-147


Molded Case Circuit Breakers<br />

Digital Solid State Sentron Sensitrip IV Series<br />

Revised on 05/31/18<br />

Technical<br />

(I r )<br />

(t ld )<br />

(I i )<br />

A. Adjustable “Continuous Amps”<br />

Rating Switch<br />

All Sensitrip IV solid state molded<br />

case circuit breakers have an adjustable<br />

ampere rating switch. Adjustments<br />

made to this switch change the<br />

continuous current rating of the breaker.<br />

B. Adjustable “Long Time<br />

Delay” Switch<br />

All Sensitrip IV circuit breakers have<br />

an adjustable long time delay switch to<br />

allow for selection of long time delays<br />

of fixed time intervals at six times the<br />

setting of the adjustable “continuous<br />

amps” rating switch.<br />

C. Adjustable “Instantaneous<br />

Pick-Up” Switch<br />

Sensitrip IV circuit breakers with an<br />

adjustable instantaneous pick up<br />

switch allow selection of a specific<br />

instantaneous trip setting.<br />

(I r )<br />

Time<br />

6 x Ir<br />

(t ld )<br />

Time<br />

(I sd )<br />

Time<br />

D. Adjustable “Short Time<br />

Pick-Up” Switch (Optional)<br />

Sensitrip IV circuit breakers with<br />

an adjustable short time pick-up<br />

switch allow for selection of short<br />

time pick-up in a range from 1.5<br />

to 10 times the setting of the<br />

maximum current rating.<br />

E. Adjustable “Short Time<br />

Delay” Switch (Optional)<br />

Sensitrip IV circuit breakers with<br />

an adjustable short time pick-up<br />

switch also contain a switch for<br />

adjustment in time delay. The<br />

adjustable short time delay switch<br />

allows for either of two modes of<br />

short time delays. One range of<br />

settings enables the breaker to be<br />

set for fixed time delays and the<br />

other range of settings enables<br />

the breaker to be set for short time<br />

delays based on l 2 t curves.<br />

(t sd )<br />

(Ig)<br />

3 x Ig<br />

(t g )<br />

Adjustable “Ground Fault Pick-Up” Switch<br />

Sensitrip IV circuit breakers containing the<br />

optional equipment ground fault protection<br />

have a ground fault pick-up setting. The<br />

ground fault pick-up settings allow for one<br />

of three time delays based on I 2 t curves.<br />

For 3-phase, 4-wire systems, an external<br />

neutral transformer is required with an<br />

ampere rating equal to the trip unit ampere<br />

rating.<br />

l n<br />

l r<br />

= Maximum circuit breaker ampere rating<br />

= Continuous current rating expressed in amperes<br />

I i = Instantaneous pickup expressed in amperes<br />

I sd = Short time pickup expressed in multiples of I r<br />

I g = Ground fault pickup expressed in amperes<br />

t sd = Short time delay - either fixed or I 2 t time delay<br />

function<br />

t ld = Long time delay - I 2 t time delay function<br />

t g = Ground fault delay - I 2 t time delay function<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Examples of Adjustment Settings<br />

Catalog Number SLD6A600LI<br />

Frame<br />

Switch 1 Swtich 2 Switch 3<br />

Rating (I n )<br />

Continuous Current Setting (I r ) Long Time Delay Setting (t ld ) Instantaneous Pickup Setting (I i )<br />

Setting 600A 200 2.5 750<br />

Description 600A max current rating 200A 2.5 sec to trip @ 6 x I r [6 x 200A = 1200A] 750A<br />

Catalog Number SLD6A600LSIG<br />

Switch 1 Switch 2 Swtich 3 Switch 4<br />

Frame<br />

Short<br />

Rating Cont. Current Long Time Short Time Instantaneous Time Delay<br />

(I n )<br />

Setting (I r ) Delay Setting (t ld ) Pickup Setting (I sd ) Pickup Setting (I i ) Setting (t sd )<br />

Ground Fault<br />

Pickup Setting<br />

(Ig)<br />

Ground Fault<br />

Delay Setting<br />

(tg)<br />

Setting 600A 300 10 1.5 5 0.1 36 [.18] 36 [.18]<br />

Description<br />

600A max<br />

current rating<br />

300A<br />

10 sec @ 6 x Ir<br />

[6 x 300A = 1800A]<br />

1.5 x Ir<br />

[1.5 x 200A = 300A]<br />

5 x In<br />

[5 x 600A = 3,000A]<br />

0.1 sec<br />

Ig = 36 x 10<br />

[36 x 10 = 360A]<br />

0.18 sec @ 3 x Ig<br />

[3 x 360 = 1,080A]<br />

7-148<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


WL Power Circuit Breakers<br />

3-pole & 4-pole, up to 6000A<br />

General<br />

Breaker Description<br />

The ever-increasing use of plant and<br />

energy management systems has<br />

intensified the demand for circuit<br />

breakers supporting multiple open<br />

protocols to monitor and control the flow<br />

of energy in the power system. The<br />

extensive and modular WL family of<br />

circuit breakers and accessories provides<br />

this for applications from 200A to 6000A.<br />

Applications<br />

WL breakers can be applied as main, tie,<br />

feeder or distribution breakers in<br />

low-voltage electrical power systems.<br />

Versions<br />

b Frame ratings: 800A to 6000A<br />

b 3 physical frame sizes<br />

b Rated nominal operating voltage up<br />

to 635VAC<br />

b Seven interrupting classes from 50kA<br />

to 200kA at 480V<br />

b Circuit breaker or non-automatic switch<br />

b WL Circuit Breakers are delivered as<br />

complete assembled breakers or<br />

individual frames, guide frames, and<br />

accessories<br />

Installation Types<br />

Fixed-mounted or Draw-out version.<br />

Standards<br />

b WL ANSI / UL 1066 Circuit Breakers<br />

will satisfy: C37.13, C37.16, C37.17,<br />

C37.50, NEMA SG3<br />

b WL UL 489 Circuit Breakers will<br />

satisfy: UL 489<br />

b WL Circuit Breakers are suitable for<br />

use in UL 1558 LV Switchgear and UL<br />

891 LV Switchboards<br />

Conditions of Application<br />

WL Circuit Breakers are designed to<br />

meet standard Industrial and Commercial<br />

application requirements.<br />

Uniform Dimensions<br />

WL Circuit Breaker dimensions differ<br />

only in the device width, which varies by<br />

frame size. With the exception of the<br />

200kA ANSI Frame Size II which has an<br />

additional 5” in depth to accommodate<br />

integral fuses and the UL489 Frame Size<br />

I which measures only 15” in height to<br />

allow six-high stacking in switchboards.<br />

Minimal Space Requirements<br />

The WL design is extremely compact<br />

without sacrificing performance and does<br />

not use energy-wasting heat sinks.<br />

Trip Units<br />

The electronic, micro processor-based<br />

trip unit is auxiliary voltage-independent<br />

for all protective functions and enables<br />

adaptation to the different protection<br />

requirements of distribution systems,<br />

motors, transformers and generators.<br />

Non-Automatic Switch<br />

A special version of the circuit breaker is<br />

used as a non-automatic switch.<br />

The non-automatic switch is constructed<br />

without a trip unit and has no protective<br />

function. A possible application is for use<br />

as a tie in systems with parallel feeds.<br />

Main Bus Connectors<br />

Breakers are equipped with standard<br />

vertical main bus connections. Horizontal<br />

bus connections are available as an<br />

option in Frame Size 1 and 2 up to<br />

2000A.<br />

Communication Capability<br />

MODBUS or PROFIBUS communications<br />

transmit the acquired and metered<br />

data, such as current values, breaker<br />

status, trip log, etc. to a central<br />

monitoring computer. With a factory<br />

installed metering function option, the<br />

WL acquires data useful for power<br />

management and can contribute to a<br />

significant savings in energy costs. A<br />

new, internal circuit breaker bus enables<br />

the expansion of breaker functionality<br />

through the integration of many<br />

secondary functions which were<br />

previously separate, including:<br />

b Control of analog displays<br />

b Options for testing the<br />

communication setup<br />

b Display of breaker status and reason<br />

for trip<br />

b Input modules for reading other<br />

external signals and transmitting<br />

these signalsvia PROFIBUS or<br />

MODBUS communication<br />

b A selection of output modules to<br />

provide contact closures based on<br />

events or measured-value setpoints.<br />

It is not only possible to monitor the<br />

breaker remotely, it is also possible<br />

to open and close the breaker as well<br />

as setting parameters remotely<br />

Operating Mechanisms<br />

Circuit breakers can be optionally<br />

delivered with different operating<br />

mechanisms, including:<br />

b Manual operating mechanism with<br />

mechanical closing (standard)<br />

b Manual operating mechanism with<br />

mechanical and electrically<br />

interlocked closing<br />

b Motorized operating mechanism with<br />

mechanical and electrically interlocked<br />

closing. Operating mechanisms with<br />

electrically interlocked closing are<br />

suitable for synchronizing tasks<br />

Auxiliary Contacts<br />

Auxiliary switches can be added according<br />

to the type of installation. They are<br />

easily mounted via front, top mounted<br />

terminal blocks.<br />

Modularity<br />

Common guide frames for the draw-out<br />

version make them completely interchangeable<br />

between the UL 489 and<br />

ANSI / UL 1066 rated circuit breakers.<br />

Components, such as auxiliary releases,<br />

motorized operating mechanisms, trip<br />

units, current sensors, auxiliary<br />

signal switches, automatic reset devices<br />

or interlocks can be used to modify or<br />

retrofit any circuit breaker to meet<br />

changing requirements. The main contacts<br />

can be replaced to extend the life<br />

of the circuit breaker and feature integrated<br />

contact wear indicators.<br />

Electronic Trip Unit Modularity<br />

Modularity is the outstanding feature of<br />

the new WL Circuit Breakers. The trip<br />

units themselves can be retrofitted with<br />

special LCDs, ground fault modules,<br />

rating plugs and communication<br />

modules.100% Rated Circuit Breaker WL<br />

circuit breakers are designed for<br />

continuous operation at 100% of their<br />

current rating without the need for<br />

external heat sinks.<br />

Conditions of Application<br />

WL Circuit Breakers are designed to<br />

meet standard Industrial and Commercial<br />

application requirements.<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-149


WL Power Circuit Breakers<br />

Communication Information<br />

General<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

7<br />

7-150<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


WL Power Circuit Breakers<br />

Electronic Trip Units<br />

General<br />

Trip Unit Functions<br />

Basic Protective Functions ETU745 ETU748 ETU776<br />

Long-time overcurrent protection L l l l<br />

Short-time delayed overcurrent protection S l l l<br />

Instantaneous overcurrent protection I l l l<br />

Neutral conductor protection N l l l<br />

Ground fault protection G u u u<br />

Additional Functions<br />

Selectable neutral protection l l l<br />

Defeatable short-time protection l — l<br />

Defeatable instantaneous protection l — l<br />

Selectable thermal memory l l l<br />

Zone selective interlocking l l l<br />

Selectable I2t or fixed short-time delay l l l<br />

Adjustable instantaneous pick-up l — l<br />

Selectable I2t or I4t long-time delay l l l<br />

Adjustable short-time delay and pick-up l l l<br />

Selectable and adjustable neutral protection l l l<br />

Dual protective setting capability — — l<br />

Dynamic arc-flash sentry — — l<br />

Extended instantaneous protection l l l<br />

Parameterization and Displays<br />

Parameterization by rotary switches (10 steps) l l —<br />

Parameterization by communication (absolute values) — l l<br />

Parameterization by menu/keypad (absolute values) — — l<br />

Remote parameterization of the basic functions — — l<br />

Remote parameterization of the additional functions — — l<br />

Alphanumeric LCD u u —<br />

Graphical LCD — — l<br />

Metering Function<br />

Metering function u u u<br />

Metering function Plus u u u<br />

Communication<br />

CubicleBUS l l l<br />

Communication via PROFIBUS-DP u u u<br />

Communication via the MODBUS u u u<br />

Communication via the Ethernet (BDA) u u u<br />

l Standard — Not available u Optional<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-151


WL Power Circuit Breakers<br />

3-pole & 4-pole, up to 6000A<br />

General<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Rating Plug<br />

It is no longer necessary to replace the<br />

current transformer to change the rated<br />

current of the breaker. Instead, you<br />

simply replace the rating plug which is<br />

easily accessible on the front of the trip<br />

unit. The circuit breaker is set to the new<br />

rated current quickly and is already<br />

correctly labeled.<br />

Long Time Overcurrent Protection<br />

with Switchable I2t/I4t Characteristics<br />

The long time overcurrent<br />

protection in the ETU745, ETU755 and<br />

ETU776 trip units can be switched<br />

between an I2t and I4t characteristic to<br />

improve coordination between upstream<br />

circuit breakers and fuses.<br />

Front Panel<br />

The front panel is designed so that it can<br />

be accessed through a cutout in the<br />

door, which means that all controls and<br />

displays are accessible even when the<br />

cubicle door is closed. The front panels<br />

of all Frame Size II and Frame Size III<br />

circuit breakers are identical, and allow<br />

for two different through-door access<br />

designs: Trip unit and front panel controls<br />

or front panel controls only. The degree<br />

of protection of the front panel is IP 20.<br />

Environmental Protection<br />

The plastics used are halogen-free and<br />

recyclable.<br />

Safety and Reliability<br />

In order to help protect the electrical<br />

distribution system and circuit breaker<br />

against unauthorized breaker operations,<br />

Exclusive Features<br />

Generator/Utility<br />

Protection Sets<br />

24/7/365 power availability is critical for<br />

some systems. On-site generation capability<br />

is growing more and more common<br />

in many systems. All of the WL digital<br />

electronic trip units allow the system<br />

designer to precisely tailor trip settings<br />

for the most demanding requirements.<br />

However, the 776 trip unit allows one set<br />

of trip settings for a fully loaded utility<br />

feed and with a simple contact closure,<br />

the trip unit toggles to a second trip set<br />

tailored to provide optimal generator protection.<br />

The wide range of settings<br />

allows the WL to provide protection for<br />

a minimal generator capacity for only<br />

essential loads, through full backup for an<br />

entire facility. This dual utility/generator<br />

protection capability in a single circuit<br />

breaker allows the system designer<br />

unparalleled, cost effective, flexibility.<br />

Dynamic Arc-Flash Sentry<br />

A unique feature of the WL trip unit<br />

allows the system designer to achieve<br />

lower levels of arc flash energy and<br />

delayed tripping for selective trip<br />

coordination purposes.<br />

a wide range of locking devices can be<br />

installed or retrofit, including:<br />

b Lockable drawout version to protect<br />

against unauthorized removal<br />

(standard)<br />

b High degree of protection through<br />

Plexiglas cover<br />

b Mechanical reclosing lockout after<br />

long-time, short-time or instantaneous<br />

trip (optional)<br />

b Devices with trip unit ETU745 or<br />

higher are equipped with temperature<br />

sensors on the BSS and<br />

COM15/COM16 (standard)<br />

b Lock provision for locking the breaker<br />

in the OPEN position<br />

b Lockable covers for the CLOSE button<br />

b Lockable racking handle prevents<br />

moving the breaker<br />

b Lockable charging handle prevents<br />

charging the springs<br />

Standard Version Features<br />

WL Circuit Breakers have the following<br />

standard equipment:<br />

b Mechanical CLOSE and mechanical<br />

OPEN push buttons<br />

b Manual operating mechanism with<br />

mechanical closing<br />

b Contact position indicator<br />

b Front panel ready-to-close indicator<br />

Dynamic Arc-Flash Sentry (DAS) employs<br />

the unique dual protective setting capability<br />

of the 776 trip unit, coupled with<br />

the ability to easily toggle to a lower arc<br />

flash parameter set. A normal operation<br />

parameter set can be optimized for<br />

selective trip coordination, while the<br />

second set is optimized for lower arc<br />

flash energy levels. The dynamic action<br />

comes from the ability to switch from<br />

the normal operation set to the arc flash<br />

limiting set based on the presence of<br />

personnel as they approach the flash<br />

protection boundary. A wide variety of<br />

switching methods may be used based<br />

on the needs of a particular facility. The<br />

capabilities range from fully automatic<br />

switching using appropriate occupancy<br />

sensors to manual switching via a<br />

key operation.<br />

Extended Instantaneous Protection<br />

Extended Instantaneous protection (EIP),<br />

another unique feature of the WL trip<br />

unit, allows the system designer to<br />

achieve full selective trip coordination up<br />

to the short-time rating of the frame<br />

while also allowing application of the<br />

breaker up to the interrupting rating of<br />

the frame. The typical power circuit<br />

breaker with an ‘LS’ trip unit, or when<br />

b Spring charge indicator<br />

b Rear vertical main contacts<br />

b Main contact replacement flag<br />

b Auxiliary plug system with bare wire<br />

pressure screw terminals. Delivery<br />

includes all auxiliary plugs necessary<br />

for both factory installed and future<br />

field installed accessories<br />

b Mechanical trip indicator of the<br />

overcurrent release system<br />

b Automatic reset after trip<br />

b The front panel cannot be removed if<br />

the circuit breaker closed<br />

b Laminated main contact fingers as part<br />

of the breaker contact strip on<br />

the drawout circuit breaker<br />

b Breaker position display in the<br />

operator’s panel<br />

b Captive crank handle for racking out<br />

the breaker<br />

b Guide frame with guide rails for easy<br />

handling of draw-out version<br />

b Breaker cannot be moved in the<br />

CLOSED state<br />

b Rated current coding between the<br />

guide frame and the breaker<br />

b Suitable for reverse feed applications<br />

b The breaker is always equipped with<br />

the required number of secondary<br />

disconnect blocks<br />

the instantaneous function is switched<br />

off on an ‘LSI’ trip unit, can only be<br />

applied up to it’s short-time rating,<br />

commonly 85kA or less. For application<br />

on systems with levels of available fault<br />

current above the short-time rating, the<br />

typical ‘LS’ power circuit breaker cannot<br />

be applied or must employ an instantaneous<br />

override. This instantaneous<br />

override is set at as much as 20% below<br />

the short-time rating and can seriously<br />

compromise selective trip coordination<br />

with downstream breakers.<br />

The WL, equipped with EIP, overcomes<br />

these limitations by providing full<br />

withstand capability, and full coordination,<br />

with a minus 0% short-time band<br />

tolerance up to 85kA on frame Size II<br />

and 100kA on Size III. Above fault currents<br />

of 20% higher than the full shorttime<br />

rating, the WL breaker is self-protecting,<br />

and the EIP function will trip the<br />

breaker instantly to protect the frame<br />

and the system from these extremely<br />

high currents, as high as 150kA on frame<br />

Size III. One added benefit is that arc<br />

flash energy is greatly reduced in this<br />

high current region due to the instantaneous<br />

trip response that EIP provides.<br />

7-152<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Lug Information<br />

Mechanical Lug<br />

Revised on 06/30/19<br />

Selection<br />

For Use<br />

With Type(s)<br />

BQ, BQH,<br />

BQHF<br />

BQE,<br />

BQF,<br />

BL, BLH,<br />

HBL,<br />

HBQ<br />

Switching<br />

Neutrals<br />

BG,<br />

BLG<br />

BQD, CQD<br />

BQD6, CQD6<br />

NGG, HGG,<br />

LGG<br />

Circuit Breaker<br />

Ampere Rating<br />

Line Side<br />

15–40<br />

45–125<br />

Load Side<br />

15–20<br />

25–35<br />

40–50<br />

55–70<br />

*exceptions in Table A<br />

80–100<br />

110–125<br />

Cables Per<br />

Lug<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

Lug Wire Range<br />

#14–#6 AWG Cu<br />

#12–#6 AWG Al<br />

#8–#1 AWG Cu<br />

#6–#1/0 AWG Al<br />

#14–#10 AWG Cu<br />

#12–#10 AWG Al<br />

#14–#6 AWG Cu<br />

#12–#6 AWG Al<br />

#8–#6 AWG Cu<br />

#8–#4 AWG Al<br />

#8–#4 AWG Cu<br />

#8–#2 AWG Al<br />

#4–#1/0 AWG Cu<br />

#2–#1/0 AWG Al<br />

#2–#1/0 AWG Cu<br />

#1/0–#2/0 AWG Al<br />

Catalog<br />

Number<br />

TC1Q1 ab<br />

TA1Q1 b<br />

Lugs are integral to<br />

Circuit Breaker<br />

Lugs are integral to<br />

Circuit Breaker<br />

Lugs are integral to<br />

Circuit Breaker<br />

Lugs are integral to<br />

Circuit Breaker<br />

Lugs are integral to<br />

Circuit Breaker<br />

Lugs are integral to<br />

Circuit Breaker<br />

Line Side (CQD, CQD6) & Load Side<br />

15–40 1<br />

#14–#6 AWG Cu<br />

#12–#6 AWG Al<br />

Integral<br />

45–100 1<br />

#8–#1 AWG Cu<br />

#6–#1/0 AWG Al<br />

Integral<br />

15–30 1<br />

#14–#6 AWG Cu<br />

#12–#6 AWG Al<br />

TC1Q1<br />

15–30 1<br />

#14–#6 AWG Cu<br />

#12–#6 AWG Al<br />

3TC1Q1 (pkg. of 3)<br />

35–125 1<br />

#8–#1/0 AWG Cu<br />

#8–#2/0 AWG Al<br />

3TC1GG20 (pkg. of 3)<br />

15–125 — NUT KEEPER PLATE TNKG3 c (pkg. of 3)<br />

Connector wire ranges and cavities are established in conjunction with Table 6.1.4.2.1 of UL 489 standards.<br />

Table A<br />

For Use<br />

With Type(s)<br />

Circuit Breaker<br />

Ampere Rating Cables Per Lug Lug Wire Range Number of Poles<br />

Load Side<br />

BQ, BL, QP 55-60 1<br />

#8–#4 AWG Cu-Al<br />

#3 AWG requires 22 or 65<br />

kAIC<br />

This exception is applicable<br />

to 1- and 2-pole only<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Note:<br />

(A) Molded case circuit breakers having a rated ampacity<br />

of 125 amperes or less are to be connected with 60 or<br />

75°C wire. Circuit breakers having a rated ampacity<br />

greater than 125 amperes shall only be cabled with<br />

75°C cable unless otherwise indicated on the circuit<br />

breaker label. Exceptions to this rule are outlined in<br />

article 110-14 C(1)(2) of the 2005 National<br />

Electrical Code.<br />

(B) Connector wire ranges and cavities are established in<br />

conjunction with Table 6.1.4.2.1 of UL 489 standards.<br />

a Lug is steel.<br />

b Sold in package of six.<br />

c One nut keeper plate is required with each lug on the<br />

NGG breaker.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-153


Lug Information<br />

Aluminum Body Lugs for Copper or Aluminum Wire<br />

Revised on 05/31/18<br />

Selection<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

For Use<br />

With Type(s)<br />

QR2, QR2H,<br />

HQR2, HQR2H<br />

All 2, 3-pole<br />

ED2, ED4, ED6,<br />

ED6 ETI,<br />

HED4,<br />

HHED6<br />

CED6<br />

All 1-pole<br />

ED, HED<br />

FXD6-A, FD6-A,<br />

HFD6,<br />

cfd6<br />

HHFD6<br />

SJD6-B,<br />

SHJD6-B<br />

SCJD6-B<br />

JXD2(A), JXD6(A),<br />

JD6(A), SJD6-B,<br />

HJD6(A), HJXD6(A)<br />

HHJXD6, HHJD6,<br />

SHJD6-B, CJD6,<br />

SCJD6-B<br />

LXD6(A), LD6(A),<br />

SLD6-B, HLD6(A),<br />

HLXD6(A), HHLXD6,<br />

HHLD6, SHLD6-B,<br />

CLD6, SCLD6-B<br />

LMD6 a , LMXD6 a ,<br />

HLMD6 a ,<br />

HLMXD6 a , MD6,<br />

MXD6, SMD6-B,<br />

HMD6, HMXD6,<br />

SHMD6-B, CMD6,<br />

SCMD6-B<br />

ND6,<br />

NXD6, SND6-B,<br />

HND6, HNXD6,<br />

SHND6-B, CND6,<br />

SCND6-B<br />

PD6, HPD6,<br />

CPD6<br />

PXD6,<br />

HPXD6,<br />

SPD6-B,<br />

SHPD6-B<br />

PD6, PXD6,<br />

HPD6, HPXD6,<br />

SPD6-B, SHPD6-B,<br />

RD6, RXD6,<br />

HRD6, HRXD6, STD<br />

Circuit Breaker<br />

Ampere Rating<br />

Cables Per<br />

Lug<br />

Lug Wire Range<br />

100-250 1 #3–300 Kcmil Al/C<br />

15–25 1<br />

#14–#10 AWG (Cu)<br />

#12–#10 AWG (Al)<br />

Catalog<br />

Number<br />

3TA1QR300<br />

(3 lugs per kit)<br />

SA1E025<br />

30–100 1 #10–#1/0 (Cu or Al) LN1E100<br />

110–125 1<br />

#3-3/0 (Cu)<br />

#1-2/0 (Al)<br />

30–60 1 #10–4 (Cu or Al)<br />

70–100 1 #4–#1/0 (Cu or Al)<br />

70–250 1<br />

#6 AWG–350 kcmil (Cu)<br />

#4 AWG–350 kcmil (Al)<br />

TA1E6125<br />

LD1E060<br />

(Load Side)<br />

LD1E100<br />

(Load Side)<br />

TA1FD350A<br />

65-200 1–2 #4 AWG–3/0 (Cu or Al) TA2J630<br />

200–400 1–2<br />

250–600 1–2<br />

500–600<br />

3/0–500 kcmil (Cu)<br />

4/0–500 kcmil (Al)<br />

3/0–500 kcmil (Cu)<br />

4/0–500 kcmil (Al)<br />

TA2J6500<br />

TA2J6500<br />

1–2 #1–500 kcmil (Cu or Al) TA2K500<br />

1–3 1/0–500 kcmil (Cu or Al) TA3K500<br />

500–800 1–2 500–750 kcmil (Cu or Al) TA2N750 b<br />

800–1200 1–4<br />

250–500 kcmil (Cu or Al)<br />

250–500 kcmil (Cu or Al)<br />

2TA4P8500 bc<br />

3TA4P8500 bd<br />

2TA4N8500 c<br />

3TA4N8500 d<br />

1200–1600 1–5 300–600 kcmil (Cu or Al) TA5P600<br />

1200–2000 1–6 300–600 kcmil (Cu or Al) TA6R600<br />

aUse TA2K500 or TA3K500 only.<br />

bUsed for 100% rated MD/ND frame breakers.<br />

Rated for 90° C cable.<br />

cContains 2 connectors plus 1 NDTS end barrier.<br />

dContains 3 connectors plus 1 NDTS end barrier.<br />

7-154<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Lug information<br />

Optional Mechanical Lugs<br />

Revised on 11/30/19<br />

Selection<br />

For Use<br />

With Type<br />

QR2, QR2H,<br />

HQR2, HQR2H<br />

Circuit Breaker<br />

Ampere Rating<br />

Cables<br />

Per Lug<br />

Lug<br />

Material<br />

Qty Per<br />

Catalog No<br />

Lug Wire Range<br />

Catalog Number<br />

100-250 1 Cu #3 - 300 Kcmil Cu ONLY) 3<br />

3TC1QR2520<br />

(3 lugs per kit)<br />

ED, HED 1, 2 & 3-pole 1, 2 & 3-pole 30-125 1 Cu #10–#1/0 (Cu) 1 TC1ED6150<br />

HFD6, HHFD6,<br />

CFD6, F(X)D6-A<br />

J(X)D2(A), J(X)D6(A),<br />

HJD6(A), HHJD6,<br />

SHJD6-B, L(X)D6(A),<br />

HHLD6, SCD6-B,<br />

HLD6(A), SHLD6-B,<br />

CJD6, CLD6, SCJD6-B,<br />

SCLD6-B<br />

SMD6-B, M(X)D6,<br />

HM(X)D6, HMD6,<br />

CMD6, SCMD6-B, SND6-B,<br />

N(X)D6, HN(X)D6,<br />

SHND6-B, CND6, SCND6-B<br />

70–250 1 Cu #6 AWG–350 kcmil (Cu) 1 TC1FD350<br />

200–600<br />

250–600<br />

1<br />

1–2<br />

1<br />

1<br />

Cu<br />

Al<br />

3/0–600 kcmil (Cu)<br />

3/0–500 kcmil (Cu)<br />

500–750 kcmil (Al)<br />

500–600 kcmil (Cu)<br />

1<br />

1<br />

TC1J6600 a<br />

TC2J6500 a<br />

1 TA1L6750<br />

500–600 1–2 Cu #1 AWG–500 kcmil (Cu) 1 TC2K500<br />

700–800 1–2 Al<br />

800–1200 1–3 Al<br />

500–750 kcmil (Cu)<br />

500–750 kcmil (Al)<br />

500–750 kcmil (Cu)<br />

500–750 kcmil (Al)<br />

2<br />

3<br />

2<br />

3<br />

2TA2N8750<br />

3TA2N8750<br />

2TA3N8750<br />

3TA3N8750<br />

R(X)D6, HR(X)D6 1600–2000 1–5 Cu 300–600 kcmil (Cu) 1 TC5R600<br />

P(X)D6, HP(X)D6,<br />

CPD6, SPD6-B, SHPD6-B<br />

1200–1600 1–4 Al 600–750 kcmil (Cu/Al) 1 TA4P750s<br />

Compression Lugs<br />

For Circuit Breaker Types<br />

Ampere<br />

Rating Poles<br />

Lugs<br />

Per Kit Lug Wire Size Catalog Number<br />

Lugs (contains indicated number of lugs and necessary hardware per kit)<br />

ED2, ED4, ED6, HED4, HHED6, CED6 15–125 1, 2, 3 1 #2/0 AWG Cu/Al CCE125<br />

QR2, QR2H, HQR2, HQR2H 100-250 2-3 1 #6 - 350kcmil Al/Cu CCQ250<br />

F(X)D6-A, HF(X)D6, HHF(X)D6, CFD6 125–250 2, 3 1 350 kcmil CCF250<br />

JXD2-A, J(X)D6-A, HJ(X)D6-A, HHJ(X)D6-A, CJD6, SJD6-B, SHJD6-B,<br />

SCJD6-B, L(X)D6-A, HL(X)D6-A, CLD6, SLD6-B, SHLD6-B, SCLD6-B<br />

200–600 2, 3 1 500 kcmil CCL600<br />

Kits (contain lugs and hardware for complete line or load end of 2 or 3-pole breaker)<br />

2 6<br />

CCM800K2<br />

M(X)D6, HM(X)D6, CMD6, SMD6-B, SHMD6-B, SCMD6-B 500–800<br />

3 9 CCM800K3<br />

500 kcmil<br />

2 8 CCN1200K2<br />

N(X)D6, HN(X)D6, CND6, SND6-B, SHND6-B, SCND6-B 900–1200<br />

3 12 CCN1200K3<br />

Distribution Lugs <br />

For Circuit Breaker Types<br />

Ampere<br />

Rating<br />

Poles<br />

Lugs<br />

Per kit<br />

NGG, HGG, LGG 15-125 1,2,3 1 6<br />

ED2, ED4, ED6, HED4, HHED6, CED6 15-125 1,2,3 1 6<br />

F(X)D6-A, HF(X)D6, HHF(X)D6, CFD6 70-250 2,3 1 6<br />

Wires<br />

Per Lug Lug Wire Size Catalog Number<br />

#6-#4 AL<br />

#14-#4 Cu<br />

TA6GG04<br />

#14-#4 AWG Cu<br />

#6-#4 AWG Al<br />

TA6ED06<br />

#14-#4 AWG Cu<br />

#6-#4 AWG Al<br />

TA6FD04<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

JXD2-A, J(X)D6-A, HJ(X)D6-A, HHJ(X)D6-A, CJD6-A,<br />

SJD6-B, SHJD6-B, SCJD6-B, L(X)D6-A, HL(X)D6-A, CLD6-A,<br />

SLD6-B, SHLD6-B, SCLD6-B<br />

200-600 2,3 1 6<br />

#14-2/0 AWG Cu<br />

#6-2/0 AWG Al<br />

TA6JD20<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

aUsed for 100% rated JD/LD frame circuit breakers.<br />

Special purpose wire connectors, not for general use.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-155


Molded Case Circuit Breakers<br />

Modifications<br />

Revised on 10/31/18<br />

General/Selection<br />

A variety of internal and external<br />

accessories, as well as modifications,<br />

are available to adapt Siemens circuit<br />

breakers to special installation<br />

requirements. UL listed internal<br />

accessories for 100 through 2000A<br />

circuit breakers are field-addable.<br />

Internal accessories fine tune an<br />

electrical distribution system,<br />

allowing control of the circuit breakers to<br />

meet special application requirements.<br />

For example, emergency situations may<br />

dictate tripping critically placed circuit<br />

breakers quickly. Shunt trips accomplish<br />

this conveniently and efficiently.<br />

Or, when voltage drops are a concern,<br />

undervoltage trips automatically open<br />

the circuit breaker at a predetermined<br />

voltage level.<br />

A wide range of external operating and<br />

mounting accessories is also available.<br />

For example, face, shallow, and back<br />

mounting plates are ideal for tailoring BQ<br />

circuit breakers to OEM applications.<br />

A complete line of operating handles<br />

and handle-blocking devices meet<br />

switchboard, enclosure and safety<br />

needs. Plug-in mounting assemblies,<br />

which simplify switchboard mounting of<br />

circuit breakers and permit breaker<br />

removal without disconnecting bus or<br />

cable connections, are available.<br />

50°C Ambient Calibration — Not UL listed and not available for solid state, 100% rated breakers<br />

or 400HZ calibrated breakers.<br />

For BL Type Circuit Breakers<br />

— Add suffix ‘M’ to catalog number<br />

(Example: B120M)....................................................................................No Charge<br />

For BQ and ED Frame Circuit Breakers<br />

— Replace ‘B’ in catalog number with ‘M’.................................................No Charge<br />

(Example: BQ3M060, ED63M060)<br />

For FD, JD, LD, LMD, MD, ND, PD, and RD Frame Circuit Breakers<br />

Non-Interchangeable Trip (3–pole only).................................................No Charge<br />

— Replace ‘B’ in catalog number with ‘M’<br />

(Example: FXD63M225, JXD63M400)<br />

400 HZ Calibration<br />

UL Listed (5KA IR)<br />

for BQ & BL Type Circuit Breakers (200A max.)...........................................Add 25% to list price<br />

— Add suffix ‘Y’ to catalog number<br />

Not UL Listed<br />

for all other Circuit Breakers, see derating tables on page 7-167 and order standard circuit breakers.<br />

Fungus Proofing<br />

All BQD, CQD, GB, GG, ED, FD, JD, LD, LMD, MD, ND, PD, RD, DG, FG, JG, LG, MG, NG, and PG<br />

Frame Circuit Breakers are inherently fungus resistant and do not require special treatment.<br />

For BL, and BQ Type Circuit Breakers............................................................Add $10.00 net per pole<br />

— Consult Sales Office for Availability<br />

For all other Circuit Breaker Types..................................................................Add $160.00 net per device<br />

— Consult Sales Office for Availability<br />

Certificate of Compliance with Test Report (catalog number CERT OF COMP.) Add $210.00 net<br />

Certificate of compliance testing must be performed on the actual device being shipped.<br />

The certificate cannot be provided after initial shipment. Order for devices with COC requirement<br />

must be placed directly with the factory by the sales office and shipped directly to the end user.<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

UL 489 Supplement SB Naval Use Breakers<br />

Breakers tested to UL 489 Supplement SB are qualified for use<br />

on non combat and auxiliary naval vessels.<br />

Various Siemens molded case breakers can be labeled "NAVAL"<br />

in compliance with UL 489 Supplement SB. See table to the<br />

right for specific breaker types and UL file references.<br />

Supplement SB testing comprises two sets of vibration tests.<br />

The first is to find mechanical resonances in the product and<br />

to subject the breaker to extreme testing at each resonant<br />

frequency. The second is a swept frequency test, in which the<br />

frequency of excitation is changed in intervals of 1Hz, and held<br />

at each frequency for five minutes. The excitation frequencies<br />

run from 4 to 33Hz, and the test is conducted in each of the<br />

three orthogonal axes of the breaker.<br />

During these tests, the breaker must not trip from the closed<br />

position, nor may the contacts touch from the open position.<br />

Calibration and insulation resistance are also verified during the test.<br />

For detailed information, refer to UL 489, Supplement SB.<br />

Ordering Information<br />

For “NAVAL” label, add $75. net per catalog number per order.<br />

Order must be placed directly with the factory by Siemens<br />

Sales Office.<br />

Breaker Type<br />

UL File<br />

BL E82615, Vol 1, Sec 1 & 4<br />

NGB E10848, Vol 10, Sec 3<br />

CED6 E10848, Vol 4, Sec 13<br />

HED4, ED6 E10848, Vol 4, Sec 11<br />

FXD6, HFD6, HHFD6 E10848, Vol 4, Sec 17<br />

HHJD6 E10848, Vol 4, Sec 20<br />

7-156<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Molded Case Circuit Breakers<br />

Internal Accessories<br />

Revised on 06/30/19<br />

General<br />

Feature Combinations<br />

The available feature combinations are shown in the chart below. For applications requiring combinations<br />

of features not listed in this chart, consult the sales office for availability.<br />

Modules Avail. On ST/ UVT/ Elect.<br />

Per Breaker ST/ ST/ AUX/ UVT/ UVT/ AUX/ AUX/ Bell Ground Grd fault<br />

Breakers Breaker Poles ST AUX ALSW ALSW UVT AUX ALSW ALSW AUX ALSW ALSW Alarm fault w/Bell<br />

QP, BQ, BL a 1 1, 2, 3 1 — — — — — 1,2 — — — — —<br />

BQD, CQD, GB, GG 1 2, 3 1 1/1 — — — — 1,2 1/1 1 — — —<br />

QR 1, 2 2, 3 1 1/1 — — — — 2 — — — — —<br />

All ED 1 1, 2, 3 1 1/1,1/2 1/1 1/1/1 1 1/1, 1/2 1/1 1/1/1 1, 2 1/1, 2/1 1 — 1 1<br />

All FD 2 2, 3 1 — — — 1 1/1 — — 1, 2 1/1 1 — — —<br />

All JD, LD, LMD b 2 2, 3 1 1 — — 1 1/1, 1/2 — — 1, 2 1/1, 1/2 1, 2 — — —<br />

SJD, SHJD,<br />

SCJD,SLD, 1 3 1 1 — — 1 1/1, 1/2 — — 1, 2 1/1, 1/2 1, 2 — — —<br />

SHLD, SCLD c<br />

All MD, ND, PD, RD<br />

Including Electronic 2 2, 3 1 1/1 — — 1 1/1, 1/2 — — 1, 2 1/1, 2/1 1, 2 — — —<br />

trip d For ED Frames For FD Frames For JD and LD Frames<br />

Shunt Trip (ST)<br />

One or all critical circuit breakers may<br />

be tripped from a distant control point<br />

by use of a shunt trip device. A shunt<br />

trip operates through an auxiliary switch<br />

contact; when the breaker opens, current<br />

is not maintained on the shunt trip coil.<br />

Undervoltage Trip (UVT)<br />

When voltage drops to a value below 35%<br />

of the nominal coil rating, the undervoltage<br />

trip device automatically opens the breaker.<br />

The operation is instantaneous, and the<br />

circuit breaker cannot be reclosed until the<br />

voltage returns to 85% of line voltage. The<br />

undervoltage trip, which is continuously<br />

energized, must be energized before the<br />

circuit breaker can be closed.<br />

Auxiliary Switch (AUX)<br />

For applications requiring remote “on” or<br />

“off” indication (or electrical interlocking),<br />

auxiliary switches are available. Each<br />

switch comprises an “A” (open when<br />

circuit breaker is open) and a “B” (closed<br />

when circuit breaker is open) contact with<br />

a common connection. (Form C)<br />

Alarm Switch (ALSW)<br />

The alarm switch contact is closed when<br />

the circuit breaker is opened automatically<br />

by an overload, short circuit, shunt trip or<br />

undervoltage trip. The alarm switch<br />

contact is open when the circuit<br />

breaker is reset.<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

S01FD60<br />

S01FD60<br />

aFactory assembled only<br />

bIf mechanical interlock is installed, no accessory module<br />

can be installed in the right pocket.<br />

cIf mechanical interlock is installed, no accessory module<br />

can be installed.<br />

dIf mechanical interlock is installed, no accessory module<br />

can be installed in the left pocket.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-157


Circuit Breakers<br />

Circuit Breaker Accessories<br />

Circuit Breaker Accessories <br />

Catalog Number For Use With Breaker Type Number of Poles Standard Package<br />

Padlocking Device<br />

For locking breaker in “OFF” position. Note “ON” position does not affect breaker fuctionally<br />

ECPLD1 Type QP, BL, QAF2, QPF2, QE, QT-Duplex, BQ, BQXD 1P 3 Pieces<br />

ECPLD1R<br />

Type QP, BL, QAF2, QPF, QE, QT-Duplex, BQ, BQXD 1P<br />

3 Pieces<br />

(Red Color)<br />

ECPLD2<br />

Type QP, BL, QAF2, QPF, QE, QT-Triplex & Quadplex, BQ, 2P<br />

3 Pieces<br />

BQXD<br />

ECPLD2R<br />

Type QP, BL, QAF2, QPF, QE, QT-Triplex & Quadplex, BQ, 2P<br />

3 Pieces<br />

BQXD (Red Color)<br />

ECPLD3 Type QP, BL, QAF2, QPF, QE, BQ 3P 1 Piece<br />

US2:ECPLD3R Type QP, BL, QAF2, QPF, QE, BQ (Red Color) 3P 1 Piece<br />

ECQLD3 Type QP, BL, BQ, BQXD 1P 10 Pieces<br />

ECQLD4 Type QT-Duplex QT-Duplex Breakers 10 Pieces<br />

ECQLN3 150-225 MBKA, QN, QNR n/a 1 Piece<br />

ECQTH4 Type QP, BL, BQH Designed for (3) 1P Breakers 1 Piece<br />

Handle Tie<br />

Provide simultaneous swiching of 2 adjacent handles.<br />

ECQTH2 Type QT Duplex Designed for (2) QT Duplex Breakers 25 Pieces<br />

ECQTH3 Type QP, BL 2P 50 Pieces<br />

Mechanical Interlock <br />

ECQML12 Type QP, BL, BQ Interlock Bracket Designed for 1” Breaker 10 Pieces<br />

Handle Blocking Device<br />

For holding breaker in “ON” or “OFF” position. Not a lockout/tagout device<br />

ECQTH2 Type QP, BL, BQ, BQXD 1P 10 Pieces<br />

ECQTH3 Type QT-Duplex 1/2” Breakers 10 Pieces<br />

Main Breaker Retainer<br />

ECMBR1 EQ Load Centers 1 Piece<br />

ECMBR2 Ultimate Load Centers 1 Piece<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Mounting Accessories<br />

MB120 Type BQ, BQH Mounting Clips 1P 20 Pieces<br />

FP9508 Type BQ, BQH FACE MOUNT PLATE 1P 10 Pieces<br />

FP9555 Type BQ, BQH FACE MOUNT PLATE 2P 10 Pieces<br />

FP9556 Type BQ, BQH FACE MOUNT PLATE 3P 10 Pieces<br />

SMB6R Type BQ MOUNTING BRACKET 1P, 2P, 3P 6 Pieces<br />

TCH65K Type BQ MOUNTING ADAPTER 500 Pieces<br />

BR2 Type BQ, BQH, BQXD Back Mounting Plates 2P 10 Pieces<br />

BR3 Type BQ, BQH, BQXD Back Mounting Plates 3P 10 Pieces<br />

BR4 Type BQ, BQH, BQXD Back Mounting Plates 4P 10 Pieces<br />

I0204ML1125CU Type QP Back Mounting Plates 1P, 2P 10 Pieces<br />

I0303ML3100CU Type QP Back Mounting Plates 3P 10 Pieces<br />

Replacement Lugs<br />

TA1Q1 Type BQ, NGG 100A Al Cu LGS n/a 6 Pieces<br />

TC1Q1 Type BQ, NGG 40A Al Cu LUGS n/a 6 Pieces<br />

Finger Shield<br />

BQFS1K Type BQXD Finger Shield (Bulk Pack) n/a 1000 Pieces<br />

BQFS2 Type BQXD Finger Shield n/a 2 Pieces<br />

Filler Plate<br />

ECQF3 1” Filler Plate n/a 5 Pieces<br />

For a complete list of standby power mechanical<br />

interlock kits, see page 1-25<br />

For use with Ultimate Load Center Main Breakers<br />

Not suitable for use on 15-50A, 10 AIC Type QP Circuit<br />

Breakers<br />

QP Type includes QPH, HQP<br />

BL Type includes BLH, HBL<br />

BQ Type includes BQH, HBQ<br />

QAF2 Type includes QAFH2, BAF2, BAFH2, QFGA2,<br />

QFGAH2, BFGA2, BFGAH2<br />

QPF Type includes QPHF, BLF, BLHF<br />

QE Type includes QEH, BLE, BLEH<br />

7-158<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Circuit Breakers<br />

Circuit Breaker Accessories<br />

General<br />

Padlocking Device<br />

ECPLD1<br />

ECQLD3<br />

ECPLD2<br />

ECPLD1R/2R/3R (Single pole<br />

pictured. 2-/3-pole available) ECQLD4 ECQTH4<br />

Handle Tie<br />

Handle Blocking Device<br />

ECQL1<br />

ECBX231M<br />

ECQTH2<br />

ECQTH3<br />

Main Breaker Retainer<br />

Mechanical Interlock<br />

7<br />

ECMBR1<br />

ECMBR2<br />

ECQML12<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Mounting Accessories<br />

FP9508<br />

FP9556<br />

MB120<br />

SMB6R<br />

I0204ML1125<br />

FP9555<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-159


Molded Case Circuit Breakers<br />

External Accessories<br />

Revised on 02/28/19<br />

Selection<br />

Handle Ties with Padlock Device<br />

Provide simultaneous switching of 2 or 3 adjacent handles.<br />

Do not provide common trip.<br />

For Use With Catalog Standard Wt Lb/<br />

Breaker Frame(s) Number Package Std Pkg<br />

BQD, NGB, HGB, LGB<br />

BQDHT2 10 1<br />

⁄2<br />

BQDHT3 10 1<br />

⁄2<br />

Padlocking Devices<br />

For locking breaker in “OFF” position.<br />

All QR HPLQR 1 1<br />

⁄4<br />

All BQD, CQD, NGB, HGB, LGB BQDPLD 01 1<br />

⁄8<br />

NGG, HGG, LGG HPLG 01 1<br />

⁄4<br />

All ED ED2HPL 01 1<br />

⁄4<br />

All FD FD6PL1 01 1<br />

⁄4<br />

All JD, LD, LMD JD6HPL 01 1<br />

⁄4<br />

All MD, ND, PD, RD MN6PLD 01<br />

1<br />

⁄4<br />

FD Padlocking<br />

Device<br />

FD6PLI<br />

Handle Blocking Devices<br />

For holding breaker in “ON” or “OFF” position.<br />

Not a lockout/tagout device.<br />

All QR HBLQR 1 1<br />

All BQD, CQD, GG, GB BQDHBD 01 1<br />

⁄4<br />

All ED E2HBL 01 1<br />

⁄4<br />

All FD FD6HB1 01 1<br />

⁄2<br />

7<br />

All JD, LD, LMD JD6HBL 01 1<br />

⁄2<br />

All MD, ND, PD, RD MN6BL 01<br />

1<br />

⁄2<br />

Handle Extensions<br />

For replacement. One extension shipped with breaker.<br />

All MD, ND, PD, RD EX11 01 2<br />

FD Handle<br />

Blocking Device<br />

FD6HB1<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Terminal Shields<br />

Breaker Type<br />

Poles<br />

Catalog<br />

Number<br />

HGG, LGG, NGG 3 TSSG3A 1<br />

JD, LD 3 JDTERMSHIELD 1<br />

MD, ND, PD, RD 3 MDTERMSHIELD 1<br />

Standard<br />

Package<br />

Handle<br />

Extension<br />

EX11<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

a Sold only in standard package quantities.<br />

7-160<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

External Accessories<br />

Revised on 02/28/19<br />

Selection<br />

Face Mounting Plates<br />

For Use With Number Catalog Standard Wt Lb/<br />

Breaker Frame(s) of Poles Number Package Std Pkg<br />

1 CQDFMB1 1 1<br />

⁄4<br />

CQD, CQD6 2 CQDFMB2n 1 1<br />

⁄4<br />

3 CQDFMB3n 1 1<br />

⁄4<br />

1 FMPG1 1 1<br />

⁄4<br />

NGG, HGG, LGG 2 FMPG2 1 1<br />

⁄4<br />

3 FMPG3 1 1<br />

⁄4<br />

Back Mounting Plates<br />

ED2, ED4, ED6, HED4, HED6 1 E2BMB 1 1<br />

⁄4<br />

Mounting Screw Kits<br />

Mounting Screw Kit<br />

MSE6<br />

CQD, CQD6 CQDSMK a 1 1 1 ⁄4<br />

NGG, HGG, LGG MSKG4 a 1 1<br />

⁄4<br />

All QR MSQR3 1 1<br />

⁄5<br />

All ED (CED6 requires 2 kits)<br />

MSE6 a 1 1<br />

⁄4<br />

MSE6100 b 100 f 1<br />

All FD (CFD6 requires 2 kits)<br />

MSF6 a 1 1<br />

⁄4<br />

MSF650 c 50 f 1<br />

All EG 1-pole MSKE1 — —<br />

All EG 2-pole MSKE2 — —<br />

All JD, LD MSJ6 a 1<br />

1<br />

⁄4<br />

All LMD MSLMD 1 1<br />

⁄4<br />

All MD, ND, MSMN 1<br />

All PD, RD MSPR6 1 2<br />

1<br />

⁄4<br />

Mechanical Interlock<br />

MI5444<br />

“MI” Mechanical Interlocks<br />

For Use With Panel g Plug-in Standard Wt Lb<br />

Breaker Type(s) Mounted Mounted Package Std Pkg<br />

All QR (Sliding Bar) SBMIQR — 1 1 1 ⁄2<br />

All FD MI5444 MI5444 1 —<br />

All JD, LD MI5413 d — 1 1<br />

All LMD MI5406 d n — 1 1<br />

All MD MI5404 e n — 1 3<br />

All ND MI5404 e n — 1 3<br />

All PD, RD MI5405 e s — — —<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

aKit consists of 4 screws and washers.<br />

bConsists of 1 screw and washers (order 100).<br />

cConsists of 1 screw and washers (order 50).<br />

d With mechanical interlock in place, no accessory can be<br />

installed into circuit breaker right pole.<br />

e Addition of the mechanical interlock will prevent<br />

accessory installation in the left pole.<br />

f Sold only in standard package quantities. Multiply List<br />

Price Each times package quantity for full price.<br />

g Mechanical interlock is not designed for use within<br />

Siemens panelboards.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-161


Molded Case Circuit Breakers<br />

External Accessories<br />

Rotary Door Mounted Operating Handles<br />

Types 1, 3, 3R , 12, 4 4X<br />

For Use<br />

With<br />

Breaker<br />

Frames<br />

Complete Mechanism<br />

Catalog Number<br />

Standard<br />

Depth<br />

Variable<br />

Depth<br />

Handle Only<br />

Catalog<br />

Number<br />

Breaker<br />

Operator<br />

Catalog<br />

Number<br />

Shaft Only<br />

Length<br />

(inches)<br />

Catalog<br />

Number<br />

ED a CRHOESD CRHOEVD<br />

RHOEBO 2 RHOSSD<br />

FD CRHOFSD CRHOFVD<br />

CRHOH c RHOFBO 12 RHOSVD<br />

JD, LD CRHOJSD CRHOJVD RHOJBO 16 RHOSXD<br />

LMD CRHOLMSD CRHOLMVD RHOLMBO<br />

3 RHONSSDs<br />

MD, ND<br />

RHONSD RHONVD RHOH c RHONBO d 12 RHONSVD<br />

PD, RD<br />

24 RHONSXD<br />

Revised on 02/28/19<br />

RHOH<br />

Selection<br />

Rotary Door Mounted Operating Handles<br />

Types 1 & 12<br />

For Use With<br />

Standard Depth Variable Depth Handle and Shaft Breaker Operator<br />

Breaker Frames Catalog Number Catalog Number Catalog Number Catalog Number<br />

CQD, NGG, HGG, LGG — RHOCQVD RHOH62 e CQDOP<br />

ED D11CEU1 D11CEU2 — —<br />

FD D11CFU1s D11CFU2 — —<br />

JD, LD — D11CJU2 — —<br />

For CQD, NGG, HGG and LGG red emergency handle, order assembly RHOCQVDE (includes handle and operator).s<br />

For CQD, NGG, HGG and LGG in a NEMA 3R enclosure, order CQDOP34 operator, RHOH handle and RHOSVD shaft.<br />

For CQD, NGG, HGG and LGG in a NEMA 4 or 4X enclosure, order CQDOP34 operator, RHOH4 handle and RHOSVD shaft.<br />

CRHOH<br />

Through Door Mounted Operating Handles b<br />

Types 1 & 12<br />

For Use With<br />

Standard Depth Variable Depth<br />

Breaker Frames<br />

Catalog Number Catalog Number<br />

CQD, NGG, HGG, LGG FMHOS —<br />

ED E2RH1 E2RHV9<br />

FD F6RH1 F6RHV9<br />

D11CEU2<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Door Latch Kits<br />

Catalog Number Catalog Number<br />

Type<br />

Right Hand<br />

Left Hand<br />

2 point latch DKR2 DKL2n<br />

3 point latch DKR3 DKL3n<br />

Standard Depth<br />

F6RH1<br />

Rotary Handle<br />

RHOCQVD<br />

Variable Depth<br />

F6RHV9<br />

n Built to order. Allow 2–3 weeks for delivery.<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

a For use on 3-pole ED frame only.<br />

b Meets the requirements of NFPA 79, section 5.3.3.1<br />

for locking external operator disconnecting devices.<br />

c For 3 or 3R, order shaft and breaker operator as shown,<br />

and handle RHOH. For 4 & 4X, order handle RHOH4.<br />

Consult sales office for additional EG operator shaft<br />

lengths.<br />

d For extended shaft support order catalog number<br />

RHONSB2.<br />

e Length of shaft is 300mm (11.8 inches).<br />

7-162<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

External Accessories<br />

Revised on 02/28/19<br />

Selection<br />

Max-Flex, Flange Mounted Variable Depth Operators c<br />

Frames<br />

GG<br />

ED<br />

FD<br />

JD, LD,<br />

SJD, SLD<br />

LMD<br />

MD, ND,<br />

PD, RD,<br />

SMD, SND,<br />

SPD<br />

NEMA<br />

Type<br />

1, 3 (R),<br />

12<br />

Complete Kit<br />

Catalog<br />

Number<br />

MFKG3R3<br />

Handle Only<br />

Catalog<br />

Number<br />

MFHG3R<br />

4 (x) MFKG4X3 MFHG4X<br />

1, 3 (R),<br />

12<br />

FHOE036 a FHOH<br />

4 (x) — FHOH4<br />

1, 3 (R),<br />

12<br />

FHOF036 FHOH<br />

4 (x) — FHOH4<br />

1, 3 (R),<br />

12<br />

FHOJ036 FHOH<br />

4 (x) — FHOH4<br />

1, 3 (R),<br />

12<br />

FHOLM036 FHOH<br />

4 (x) — FHOH4<br />

1, 3 (R),<br />

12<br />

FHON048 FHOHN<br />

4 (x) — FHOHN4<br />

Breaker Operator<br />

Catalog Number<br />

MFMG<br />

FHOEBO a<br />

FHOFBO<br />

FHOJBO<br />

FHOLMBO<br />

FHONBO<br />

36" Cable<br />

Catalog Number<br />

MFCF036<br />

FHOEC036<br />

FHOFC036<br />

FHOJC036<br />

FHOJC036<br />

FHONC048 b<br />

Max-Flex handles are available with solid black handles instead of the customary “red for on” flange handle. These are<br />

preferred for use in IECmarkets, where red handles have specific meaning. Order components separately, appending the<br />

letter “i” to the catalog number (e.g. FHOHI).<br />

FHOH<br />

FHOFBO<br />

Alternate Length Cable Only<br />

ED FD JD/LD/LMD MD/ND/PD/RD<br />

Inches Catalog Number Catalog Number Catalog Number Catalog Number<br />

048 FHOEC048 FHOFC048 FHOJC048 FHONC048<br />

060 FHOEC060 FHOFC060 FHOJC060 FHONC060<br />

072 FHOEC072 FHOFC072 FHOJC072 FHONC072<br />

96 FHOEC096 FHOFC096 FHOJC096 FHONC096<br />

120 FHOEC120s FHOFC120 FHOJC120s FHONC120s<br />

144 FHOEC144s FHOFC144s FHOJC144s FHONC144s<br />

Handle Auxiliary Switch<br />

For use with Max-Flex and Rotary Door operators (FHOH and RHOH). 1 NO and 1 NC contact (Form C).<br />

For Use With<br />

ED, FD, JD, LD, LMD, ND, PD, RD, SD, Max Flex<br />

Fixed Depth Flange Mounting<br />

Catalog Number<br />

HAS1<br />

Minimum<br />

Left Hand Mount<br />

Right Hand Mount<br />

Enclosure NEMA<br />

Frames Depth Type Catalog Number Catalog Number<br />

ED 6.44<br />

1, 3R, 12 FDFBELs FDFBERs<br />

4, 4X FDFBEL4s FDFBER4s<br />

FD 6.44<br />

1, 3R, 12 FDFBFLs FDFBFRs<br />

4, 4X FDFBFL4s FDFBFR4s<br />

FDFBFR<br />

FHOFC036<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Max-Flex handles are available with solid black handles instead of the customary “Red for On” flange handle. These are<br />

preferred for use in IECmarkets, where red handles have specific meaning. Order components separately, appending the<br />

letter “i” to the catalog number (e.g. FHOHI).<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

aFor 1- or 2-pole breaker order FHOED036 complete kit or<br />

FHOEDBO breaker operator only. Use MFHM3R handle.<br />

b48 inch cable is standard length for M through R frame<br />

Max-Flex operators.<br />

cMeets requirements of NFPA 79, section 5.3.3.1 for<br />

locking external operator disconnecting devices<br />

dConsult sales office for additional cable lengths for EG<br />

Flex Shaft Operators. For 3-Pole only.<br />

3-Pole ED only.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-163


Molded Case Circuit Breakers<br />

External Accessories<br />

Selection/Dimensions<br />

Telemand ® Motor Operator<br />

AC<br />

Hinged to Open Down<br />

Breaker Frame Voltage Catalog Number<br />

ED except CED<br />

120 MOE6120<br />

240 MOE6240s<br />

ED motor operator opens downward.<br />

Breaker DC Hinged to Open Right AC Hinged to Open Right<br />

Frame Voltage Catalog Number Voltage Catalog Number<br />

24 MOF6024DCs 120 MOF6120<br />

FD 48 MOF6048DCs 240 MOF6240<br />

125 MOF6125DCs<br />

24 MOJ6024DCs 120 MOJ6120<br />

JD, LD 48 MOJ6048DCs 240 MOJ6240<br />

125 MOJ6125DCs<br />

24 MOLMD6024DCs 120 MOLMD6120<br />

LMD 48 MOLMD6048DCs 240 MOLMD6240<br />

125 MOLMD6125DCs<br />

MD, ND, — — 120 EMOPL120MN<br />

PD, RD — — 240 EMOPL240MN<br />

To order FD through RD motor operators with Left side hinges, add “L” to catalog number (e.g. MOF6120L).<br />

List prices are the same.s<br />

Telemand Motor Operator<br />

FD, JD, LD, LMD, MD, ND, PD, RD<br />

Frames<br />

Dimensions<br />

Frame A B C D E F<br />

ED 7.04 4.31 — 4.31 13.84 8.84<br />

FD 9.50 4.55 1.60 6.84 9.70 7.58<br />

JD, LD, LMD 11.00 7.50 0.79 8.34 9.85 7.74<br />

MD, ND, PD, RD 16.00 9.00 — 9.83 13.13 10.13<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Operating Currents<br />

On<br />

Off<br />

Catalog In-Rush Running Time In-Rush Running Time Reset<br />

Number (Amps) (Amps) (msec) (Amps) (Amps) (msec) (Amps)<br />

MOE6120 10.25 2.3 550 10 2.3 400 2.3<br />

MOE6240 5.2 1.1 500 5 1 330 1.1<br />

MOF6120/L 13.6 5.5 200 13.6 5.5 175 5.5<br />

MOF6240/L 7.6 3.5 200 7.6 3.5 185 3.5<br />

MOLMD6120/L 13.6 6 210 13.6 6 185 6<br />

MOJ6120/L 13.6 6 210 13.6 6 185 6<br />

MOJ6240/L 7.6 3.5 217 7.6 3.5 185 3.5<br />

EMOPL120MN 15 5.5 500 15 5.5 500 5.5<br />

EMOPL240MN 7.6 3.25 500 7.6 3.25 500 3.25<br />

Front View<br />

Bottom View<br />

For inches / millimeters conversion, see Application Data section.<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

7-164<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Molded Case Circuit Breakers<br />

External Accessories<br />

Revised on 09/30/20<br />

Selection<br />

Plug-In Mounting Assemblies, Including Base and Tulip Assemblies<br />

Base<br />

Line Side<br />

Load Side<br />

Steel Switchboard<br />

All ND<br />

2 PC5664 c s PC5664 c s<br />

PL9699<br />

3 PC5666 c PC5666 c<br />

For Use With<br />

Mounting Plate a<br />

Breaker Frames Poles Catalog Number b Catalog Number b Catalog Number<br />

All ED 2 PC2637s PC2638s<br />

except CED 3 PC2657 PC2658<br />

PL2616<br />

CED<br />

2 PC2637s PC2638s<br />

3 PC2657 PC2658<br />

PL2617<br />

All FD 2 PC4753s PC4753s<br />

except CFD 3 PC4754 PC4754<br />

PL4762<br />

CFD<br />

2 PC4753s PC4753s<br />

3 PC4754 PC4754<br />

PL4763<br />

All JD 2 PC5777s PC5777s<br />

except CJD 3 PC5778 PC5778<br />

PL5796<br />

Kit CJD, SCJD 3 PCCJD PCCJD PL5797<br />

All LD 2 PC5660s PC5660s<br />

except CLD<br />

PL5680<br />

3 PC5661 PC5661<br />

Switchboard<br />

Kit CLD, SCLD 3 PCCLD PCCLD PL5797<br />

Mounting<br />

Plate<br />

2 PC5662s PC5662s<br />

All MD<br />

PL9698<br />

3 PC5663 PC5663<br />

Tulip<br />

Assemblies<br />

Tulip Assemblies Separately<br />

For Frame<br />

ED<br />

FD<br />

JD<br />

LD<br />

MD<br />

ND<br />

3-Pole<br />

Catalog Number<br />

TCE3s<br />

TCF3s<br />

TCJ3s<br />

TCL3s<br />

TCM3s<br />

TCN3s<br />

RS4756<br />

RS4755<br />

Rear-Connecting Studs<br />

For Use<br />

Extension<br />

With<br />

Behind<br />

Line Side<br />

Load Side<br />

Breaker Ampere Breaker<br />

Frames Rating Description (inches) Catalog Number d Catalog Number d<br />

100 Line Side (Short) 2.38 RS2643 e s —<br />

All ED<br />

100 Load Side (Short) 2.38 — RS2644 e s<br />

100 Line Side (Long) 4.88 RS2641 e s —<br />

100 Load Side (Long) 4.88 — RS2642 e s<br />

All FD<br />

250 Short 3.12 RS4756 e s RS4756 e s<br />

250 Long 7.06 RS4755 e s RS4755 e s<br />

All JD<br />

400 Short 5.85 RS5774s RS5774s<br />

400 Long 11.20 RS5773s RS5773s<br />

All LD<br />

600 Short 5.85 RS5784s RS5784s<br />

600 Long 11.20 RS5783s RS5783s<br />

CJD, SCJD<br />

CLD, SCLD<br />

Add required shield kit.<br />

CLRSJL3<br />

LM(X)D6,<br />

800<br />

Short 5.85 RS5788s RS5788s<br />

HLM(X)D6 Long 11.20 RS5787s RS5787s<br />

All MD, 1200 Short 5.50 RS5786s RS5786s<br />

ND 1200 Long 8.00 RS5785s RS5785s<br />

Circuit Breaker<br />

With Rear-Connecting Studs<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

s Built to order. Allow 6–8 weeks for delivery.<br />

aMust be ordered separately with other plug-in<br />

assemblies.<br />

bEach piece catalog number consists of (1) mounting<br />

block assembly and required tulip assemblies (2) for<br />

2-pole, (3) for 3-pole<br />

cFor vertical bus mounting — for horizontal, substitute<br />

PC5665 for PC5664 and PC5667 for PC5666.<br />

dPrice includes one current stud, insulating tube, stud<br />

nuts and terminal shields, when required.<br />

eFor proper electrical clearance, studs must alternate<br />

between short and long stud lengths on circuit breaker<br />

poles (e.g. SLSLSL or LSLSLS).<br />

fPlug-in assembly for EG breakers include line and load<br />

side in one assembly.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-165


Molded Case Circuit Breakers<br />

Unusual Operating Conditions<br />

Revised on 05/31/18<br />

Reference<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Note: The information provided on this and the next page is intended for reference and recommendation only. Because several<br />

variables can act on a circuit breaker’s performance at the same time, the data below is based less on controlled testing,<br />

than on experience and engineering judgment. Contact Siemens for further information on special conditions and treatment.<br />

High Ambient Temperatures<br />

Because thermal-magnetic trip breakers<br />

are temperature sensitive and calibrated<br />

for a specific ambient of 40° C (104° F)<br />

(average enclosure temperature), a<br />

higher ambient will cause the breaker to<br />

trip at lower current than its nameplate<br />

rating, in other words, causing the<br />

breaker to “derate” (see Table 1).<br />

Similarly, the current carrying capacity<br />

of a circuit conductor is based upon a<br />

certain ambient temperature, a higher<br />

ambient will reduce its current carrying<br />

capacity, causing it to “derate.” Thus,<br />

with a fluctuating temperature, a<br />

thermal-magnetic breaker will derate<br />

nearly parallel with its connected circuit<br />

conductors and maintain close circuit<br />

protection. If the application temperature<br />

exceeds 40° C (104° F) and is known,<br />

either a breaker specially calibrated for<br />

the higher ambient or one oversized<br />

according to Table 1 may be selected.<br />

In a case such as this, the circuit<br />

conductors should be oversized as well.<br />

Siemens Sensitrip ® IV and Type SB<br />

Encased Systems Breakers are<br />

insensitive to temperature changes.<br />

However, they do include circuitry to<br />

protect the components from<br />

abnormally high temperatures.<br />

Moisture — Corrosion<br />

For atmospheres having high moisture<br />

content and / or where fungus growth is<br />

prevalent, a special preventive treatment<br />

may be required.<br />

Where the air is heavily laden with<br />

corrosive elements, breakers made<br />

with special corrosion-resistant<br />

finishes may be required.<br />

Altitude<br />

Reduced air density at altitudes greater<br />

than 6600 ft. (2000 meters) affects the<br />

ability of a molded case circuit breaker<br />

to transfer heat and interrupt faults.<br />

Therefore, circuit breakers applied at<br />

these altitudes should have interrupting,<br />

insulation and continuous currents<br />

derated as indicated in Figure 1.<br />

Table 1 — Temperature Derating Data for Thermal-Magnetic Breakers<br />

Reference<br />

Ampere<br />

Rating at<br />

40°C (104°F)<br />

Altitude in Feet (Meters)<br />

Ampere Rating at:<br />

50°C<br />

(122°F)<br />

13,000 (4,000)<br />

12,000 (3,675)<br />

11,000 (3,350)<br />

10,000 (3,000)<br />

9,000 (2,750)<br />

8,000 (2,400)<br />

7,000 (2,100)<br />

6,000 (1,800)<br />

60°C<br />

(140°F)<br />

15 13 11<br />

20 18 16<br />

25 23 21<br />

30 28 26<br />

35 30 28<br />

40 37 34<br />

50 46 42<br />

60 56 52<br />

70 65 60<br />

90 84 78<br />

100 94 87<br />

125 114 100<br />

150 136 120<br />

175 159 140<br />

200 182 160<br />

225 205 180<br />

250 235 220<br />

300 276 252<br />

350 325 301<br />

400 372 340<br />

500 468 435<br />

600 564 525<br />

700 658 613<br />

800 754 704<br />

900 828 749<br />

1000 900 825<br />

1200 1090 1000<br />

1400 1304 1148<br />

1600 1500 1320<br />

1800 1690 1485<br />

2000 1880 1650<br />

Siemens Breaker Frames<br />

BQ,<br />

BL,<br />

BQD,<br />

CQD,<br />

GG,<br />

GB,<br />

ED<br />

QR<br />

FD<br />

JD<br />

LD<br />

MD<br />

ND<br />

PD<br />

RD<br />

1.0 .95 .90 .85 .80 .75<br />

Rating Correction Factor<br />

Figure 1 — Altitude Adjustment<br />

7-166<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Molded Case Circuit Breakers<br />

Unusual Operating Conditions<br />

400 Hz Systems a<br />

Siemens molded case circuit breakers<br />

can be applied for overcurrent protection<br />

on 400Hz systems, commonly used to<br />

power computer installations, aircraft,<br />

military and other specialty equipment.<br />

Below are basic guidelines.<br />

Circuit Breaker Derating Required<br />

This table lists the maximum continuous<br />

current carrying capacity for Siemens<br />

breakers at 400Hz. Due to the increased<br />

resistance of the copper sections<br />

resulting from the skin effect produced<br />

by eddy currents at these frequencies,<br />

circuit breakers in many cases require<br />

derating. The thermal derating on these<br />

devices is based upon 100%,<br />

three phase application in open air in a<br />

maximum of 40° C (104° F) with 48 in.<br />

(1219 mm) of the specified cable or bus<br />

at the line and load side. Additional<br />

derating of not less than 20% will be<br />

required if the circuit breaker is to be<br />

utilized in an enclosure. Further derating<br />

may be required if the enclosure<br />

ambient temperature exceeds 40° C<br />

(104° F).<br />

Cable and Bus Sizing<br />

The cable and bus sizes to be utilized<br />

at 400Hz are not based on standard<br />

National Electric Codes tables for 60Hz<br />

application. Larger cross sections are<br />

necessary at 400Hz. All bus bars<br />

specified are based upon mounting<br />

the bars in the vertical plane to allow<br />

maximum air flow. All bus bars are<br />

spaced at a minimum of 0.25 in. (6 mm)<br />

apart. Mounting of bus bars in the<br />

horizontal plane will necessitate<br />

additional drafting. Edgewise orientation<br />

of the bus may change the maximum<br />

ratings indicated. If additional information<br />

is required for other connections of cable<br />

or bus, contact Siemens for information.<br />

Application Recommendations<br />

It is recommended that temperatures be<br />

measured on the line and load terminals<br />

or T-connectors of the center pole. These<br />

Reference<br />

are usually the hottest terminals with a<br />

balanced load. A maximum temperature<br />

of 75° C (35° C over a maximum ambient<br />

of 40° C) would verify the particular<br />

application. Temperature profiles taken<br />

on these breakers can be correlated to<br />

ensure that the hottest points within<br />

the breaker are within the required<br />

temperature limits.<br />

Factory Configuration<br />

When required, molded case circuit<br />

breakers may be factory calibrated for<br />

400Hz application. These breakers are<br />

specially labeled for 400Hz usage and<br />

their nameplate current rating will<br />

include the necessary derating factory.<br />

The highest “Maximum Continuous<br />

Amperes” rating at 400Hz, found in the<br />

table below approximates the highest<br />

specially calibrated 400Hz nameplate<br />

ampere rating available for a given<br />

frame size. Contact Siemens for<br />

ordering information on other<br />

breakers applied in 400Hz systems.<br />

400Hz Breakers<br />

Maximum Continuous Ampere Rating<br />

75°C (167°F)<br />

At 40°C (104°F) b<br />

Copper<br />

Siemens<br />

60HZ 400HZ Cable per Pole<br />

Breaker Enclosed No of Wire<br />

Type Open Air Open Air c After Derating Pieces Size<br />

015 015 012 1 #14<br />

020 020 016 1 #12<br />

025 025 020 1 #10<br />

030 030 024 1 #10<br />

035 035 028 1 #10<br />

040 040 032 1 #8<br />

ED2, ED4, ED6, 045 043 034 1 #8<br />

BQD, HED4, 050 048 038 1 #8<br />

HED6, CED6, 060 057 046 1 #6<br />

GG, GB<br />

070 067 054 1 #4<br />

080 076 061 1 #4<br />

090 086 069 1 #3<br />

100 095 076 1 #3<br />

110 105 084 1 #2<br />

125 119 095 1 #1<br />

070 063 050 1 #4<br />

080 072 058 1 #4<br />

090 080 064 1 #3<br />

QR2, QR2H,<br />

HQR2, HQR2H,<br />

FD6, FXF6,<br />

HFD6, HFXD6,<br />

CFD6<br />

100 090 072 1 #3<br />

110 095 075 1 #2<br />

125 105 084 1 #1<br />

150 125 100 1 #1/0<br />

175 140 112 1 #2/0<br />

200 160 128 1 #3/0<br />

225 180 144 1 #4/0<br />

250 200 160 1 250 kcmil<br />

200 170 136 1 #3/0<br />

225 190 152 1 #4/0<br />

JXD2, JD6,<br />

JXD6, HJD6, 250 210 168 1 250 kcmil<br />

HJXD6, HHJD6, 300 240 192 1 350 kcmil<br />

HHJXD6, CJD6<br />

350 260 208 1 500 kcmil<br />

400 300 240 2 #3/0<br />

200 170 170 2 #3/0<br />

JD6, JXD6,<br />

225 190 190 2 #4/0<br />

HJD6, HJXD6 250 210 210 1 250 kcmil<br />

100% Rated 300 240 240 1 350 kcmil<br />

350 260 260 1 500 kcmil<br />

400 300 300 2 #3/0<br />

aThe information provided on this page is intended for<br />

reference and recommendation only. Because several<br />

variables can act on a circuit breaker’s performance at<br />

the same time, the data above is based less on<br />

controlled testing, than on experience and engineering<br />

judgment. Contact Siemens for further information on<br />

special conditions and treatment.<br />

bAdditional derating may be required if the ambient<br />

Maximum Continuous Ampere Rating<br />

75°C (167°F)<br />

At 40°C (104°F) b<br />

Copper<br />

Siemens<br />

60HZ 400/415HZ Cable per Pole<br />

Breaker Enclosed No of Wire<br />

Type Open Air Open Air c After Derating Pieces Size<br />

0250 0210 168 1 250 kcmil<br />

LD6, LXD6,<br />

HLD6, HLXD6,<br />

HHLD6,<br />

HHLXD6,<br />

CLD6<br />

LD6, LXD6,<br />

HLD6, HLXD6,<br />

100% Rated<br />

MD6, MXD6,<br />

HMD6,<br />

HMXD6, CMD6<br />

MD6, MXD6,<br />

HMD6,<br />

HMXD6, CMD6<br />

100% Rated<br />

ND6, NXD6<br />

HND6, HNXD6,<br />

CND6<br />

ND6, NXD6<br />

HND6, HNXD6,<br />

CND6<br />

100% Rated<br />

PD6, PXD6,<br />

HPD6, HPXD6,<br />

CPD6,<br />

PD6, PXD6,<br />

HPD6, HPXD6,<br />

CPD6<br />

100% Rated<br />

RD6, RXD6,<br />

HRD6, HRXD6<br />

80% Rated<br />

0300 0240 192 1 350 kcmil<br />

0350 0260 208 1 500 kcmil<br />

0400 0300 240 2 #3/0<br />

0450 0340 272 2 #4/0<br />

0500 0375 300 2 250 kcmil<br />

0600 0420 336 2 350 kcmil<br />

0250 0210 210 1 250 kcmil<br />

0300 0240 240 1 350 kcmil<br />

0350 0260 260 1 500 kcmil<br />

0400 0300 300 2 #3/0<br />

0450 0340 340 2 #4/0<br />

0500 0375 375 2 250 kcmil<br />

0600 0420 420 2 350 kcmil<br />

0500 0400 320 2 250 kcmil<br />

0600 0430 360 2 350 kcmil<br />

0700 0500 400 3 250 kcmil<br />

0800 0560 448 3 300 kcmil<br />

0500 0400 400 2 250 kcmil<br />

0600 0430 430 2 350 kcmil<br />

0700 0500 500 3 250 kcmil<br />

0800 0560 560 3 300 kcmil<br />

0800 0560 448 3 300 kcmil<br />

0900 0600 480 3 350 kcmil<br />

1000 0650 520 3 400 kcmil<br />

1200 0780 624 4 350 kcmil<br />

0900 0600 600 3 350 kcmil<br />

1000 0650 650 3 400 kcmil<br />

1200 0780 780 4 350 kcmil<br />

1200 0780 624 4 400 kcmil<br />

1400 0850 680 4 500 kcmil<br />

1600 0960 768 5 500 kcmil<br />

1200 0780 780 4 400 kcmil<br />

1400 0850 850 4 500 kcmil<br />

1600 0960 960 5 500 kcmil<br />

1600 0960 768 5 500 kcmil<br />

1800 1080 864 5 500 kcmil<br />

2000 1200 960 6 500 kcmil<br />

temperature is greater than 40°C (104°F).<br />

cCalculated after derating to compensate for the heating<br />

of the copper conductor, caused by the skin effect<br />

generated by eddy currents produced at 400/415HZ.<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-167


Molded Case Circuit Breakers<br />

Notes<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

7<br />

7-168<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


VL Circuit Breakers<br />

Catalog Numbering System<br />

Selection/Application<br />

Interrupting Class<br />

N — Normal<br />

H — High<br />

L — Very High<br />

C — Trip Unit Only<br />

Frame Family<br />

D — Type DG<br />

F — Type FG<br />

J — Type JG<br />

Breaker Type<br />

L — Type LG<br />

M — Type MG<br />

N — Type NG<br />

E — Global DG, FG Frame Only<br />

600 Y/347 V<br />

G — Global interchangeable (UL,<br />

IEC, CE, CSA, NOM , CCC )<br />

J — 240V rated JG frame,<br />

Non-interchangeable only<br />

K — Global, Non-interchangeable<br />

(DG, FG, LG-frame)<br />

M — Motor Circuit Protector<br />

P — Motor Circuit Protector<br />

(DG, FG Only)<br />

P — Type PG<br />

R — Molded Case Switch<br />

(DG, FG, LG-frame)<br />

S — Molded Case Switch<br />

T — Trip Unit Only<br />

V — Thermal Magnetic, standard 40°C<br />

ambient, 600VAC 25kA, UL/CSA<br />

(LG frame)<br />

W — 100% rated, Non-interchangeable<br />

(DG, LG-frame)<br />

X — Global Non-interchangeable<br />

Y — 100% rated, Non-interchangeable<br />

Number of Poles<br />

2, 3<br />

Trip Unit<br />

F — Frame only, without trip unit<br />

S — Molded Case Switch<br />

B — Thermal Magnetic, standard 40° C ambient<br />

A — Electronic w/ LCD, LSI or 3P (neutral protected)<br />

L — Magnetic Only, Motor Circuit Protector - Low G — Electronic w/ LCD, LSIG, 3P/4W (selectable residual or<br />

instantaneous range<br />

return type ground fault protection)<br />

J — Magnetic Only, Motor Circuit Protector - Low K — Electronic with LCD, LSI and GF alarm only, 3P/4W<br />

instantaneous range (LG-frame)<br />

(selectable residual or return type ground fault alarm)<br />

M — Magnetic Only, Motor Circuit Protector - Standard R — Electronic LI or 3P (neutral protected)<br />

instantaneous range<br />

T — Electronic LSI or 3P (neutral protected)<br />

Y — Magnetic Only, Motor Circuit Protector - Standard V — Electronic, LSIG or 3P/4W, residual ground fault protection<br />

instantaneous range (LG-frame)<br />

W — Electronic, LIG or 3P/4W, residual ground fault protection<br />

H — Magnetic Only, Motor Circuit Protector - High<br />

instantaneous range<br />

Continuous Current Rating<br />

For DG use 050, 060, 070, 080, 090, 100, 110, 125, 150<br />

For FG use 100, 110, 125, 150, 175, 200, 225, 250<br />

For JG use 250, 300, 350, 400<br />

For LG use 400, 500, 600<br />

For MG use 600, 700, 800<br />

For NG use 800, 900, 100 (1000A), 120 (1200A)<br />

For PG use 120 (1200A), 140 (1400A), 160 (1600A)<br />

Terminations<br />

B — Load End Standard (cu/al) Lugs<br />

L — Line & Load Standard (cu/al) Lugs<br />

X — No Lugs (use only if accessory suffixes are to follow)<br />

Accessories<br />

Auxiliary and Alarm Switch Combinations<br />

Suffix Description<br />

A1 — 1 Alarm (includes 1NO & 1NC switch with a 2 Aux./1 Alarm Base, for frames DG to LG) Note: A1 and A3 include 1NO and 1NC switch for<br />

A2 — 2 Aux (1NO & 1NC switch with a 3 Aux. Base, for frames DG to LG) alarm purposes, only one of these switches may<br />

A3 — 2 Aux + 1 Alarm (2NO & 2NC switches with a 2 Aux./1 Alarm Base, for frames DG to LG) be used as there is only one space for an alarm.<br />

A3 — 2 Aux + 2 Alarm (2NO & 2NC switches with a 2 Aux./2 Alarm Base, for frames MG to PG)<br />

A4 — 4 Aux (2NO & 2NC switches with a 4 Aux. Base, for frames MG to PG)<br />

Shunt Trips<br />

RB — 24 VDC RM — 48-60 VAC<br />

RC — 48-60 VDC RN — 110-127 VAC<br />

RD — 110-127 VDC RS — 208-277 VAC<br />

LCD = Liquid Crystal Display<br />

RE — 250 VDC RV — 380-600 VAC<br />

LI = Long Delay & Instantaneous trip functions<br />

Under Voltage Releases<br />

UA — 12 VDC UN — 110-127 VAC<br />

LSI = Long Delay, Short Delay, & Instantaneous trip functions<br />

LSIG = Long Delay, Short Delay, Instantaneous, & Ground Fault trip functions<br />

GF = Ground Fault<br />

UB — 24 VDC UP — 208 VAC<br />

3P = 3-pole<br />

UC — 48 VDC UR — 220-250 VAC<br />

4W = 4-wire<br />

UD — 110-127 VDC US — 277 VAC<br />

UE — 220-250 VDC UT — 380-415 VAC<br />

UG — 60 VDC UU — 440-480 VAC<br />

UK — 24 VAC<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Select Frames<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-169


VL Circuit Breakers<br />

Catalog Numbering System<br />

Selection<br />

If ordering factory-installed accessories or special modifications, you must order a 15-digit catalog number. See the examples<br />

below for a detailed explanation. The 15 digit number is achieved by placing X’s in positions not being occupied by an<br />

accessory/modification. Contact Siemens for circuit breakers configured with accessories.<br />

Auxiliary Switch Example:<br />

H F G 3 B 2 0 0 L A 2 X X X X<br />

Standard 9-digit Aux. Switch Completes Cat #<br />

Shunt Trip / UVR Example:<br />

H F G 3 B 2 0 0 L X X U N X X<br />

Standard 9-digit<br />

UVR<br />

Completes Cat #<br />

Shunt Trip / Auxiliary Switch Example:<br />

H F G 3 B 2 0 0 L A 2 R N X X<br />

Standard 9-digit Aux. Shunt Completes<br />

Switch Trip Cat #<br />

Non-Interchangeable Trip Breakers Example:<br />

H F X 3 B 2 0 0 L<br />

Standard 9-digit<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

7<br />

7-170<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


VL Circuit Breakers<br />

Technical Overview<br />

Technical<br />

Frame Summary and Ratings Table<br />

Frame Family DG FG JG<br />

Continuous Ampere Range 30 to 150A 40 to 250A 70 to 400A<br />

Number of Poles 2, 3 2, 3 2, 3<br />

Maximum Voltage Rating 600Y/347 600Y/347 600V<br />

Type of Protection<br />

Thermal-Magnetic u u u<br />

Electronic u u u<br />

Electronic with LCD u u u<br />

Motor Circuit Protector u u u<br />

Molded Case Switch u u u<br />

100% Rated Breaker ETU only — u<br />

Interchangeable Trip Unit — — u<br />

W In.(mm) 4.1 (105) 5.5 (139)<br />

H 7.3 (175) 11 (279)<br />

D 3.4 (81) 4.2 (102)<br />

D1 4.2 (107) 5.4 (138)<br />

Type N – Normal Interrupting Rating a , RMS Symmetrical Amperes (kA)<br />

240Vac 65 65 65<br />

UL 480Vac 35 35 35<br />

600Vac 18 18 25<br />

240Vac 65/65 65/65 65/65<br />

IEC 415Vac 40/40 40/40 45/45<br />

(l CU /l CS )<br />

690Vac 12/6 12/6 12/6<br />

DC Voltages – Interrupting Rating (kA) d<br />

250Vdc - 2p 30 30 30<br />

500Vdc - 3p c 18 18 25<br />

Type H – High Interrupting Rating a , RMS Symmetrical Amperes (kA)<br />

240Vac 100 100 100<br />

UL 480Vac 65 65 65<br />

600Vac 18 18 25<br />

240Vac 100/75 100/75 100/75<br />

IEC 415Vac 70/70 70/70 70/70<br />

(l CU /l CS )<br />

690Vac 12/6 12/6 15/8<br />

DC Voltages – Interrupting Rating (kA) d<br />

250Vdc - 2p 30 30 30<br />

500Vdc - 3p c 18 25 35<br />

600Vdc - 3p 42 42 65<br />

Type L – Very High Interrupting Rating a , RMS Symmetrical Amperes (kA)<br />

240Vac 200 200 200<br />

UL 480Vac 100 100 100<br />

600Vac 18 18 25<br />

240Vac 200/150 200/150 200/150<br />

IEC 415Vac 100/75 100/75 100/75<br />

(l CU /l CS )<br />

690Vac 12/6 12/6 15/8<br />

DC Voltages – Interrupting Rating (kA) d<br />

250Vdc - 2p 30 30 30<br />

500Vdc - 3p c 18 30 35<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

a UL does not recognize AIC ratings for Molded Case<br />

Switches or Motor Circuit Protectors.<br />

b For 600 VDC breakers see page 7-204.<br />

c 500Vdc nominal, 600Vdc max. for ungrounded DC UPS<br />

systems.<br />

d DC Interruption Ratings do not apply to electronic trip<br />

circuit breakers.<br />

DG & FG breakers are 600Y/347V.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-171


VL Circuit Breakers<br />

Technical Overview<br />

Technical<br />

Frame Summary and Ratings Table — Continued<br />

Frame Family LG MG NG PG<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Continuous Ampere Range 150 to 600A 200 to 800A 300 to 1200A 400 to 1600A<br />

Number of Poles 2, 3 2, 3 2, 3 3<br />

Maximum Voltage Rating 600V 600V 600V 600V<br />

Type of Protection<br />

Thermal-Magnetic u u u u<br />

Electronic u u u u<br />

Electronic with LCD u u u u<br />

Motor Circuit Protector u u u —<br />

Molded Case Switch u u u u<br />

100% Rated 400/500 Amp u u u<br />

Interchangeable Trip Unit — u u u <br />

W In.(mm) 5.5 (139) 7.5 (190) 9 (229)<br />

H 11 (279) 16 (406) 16 (406)<br />

D 4.2 (102) 4.7 (114) 6.2 (157)<br />

D1 5.4 (138) 5.9 (151) 8.1 (207)<br />

Type N – Normal Interrupting Rating a , RMS Symmetrical Amperes (kA)<br />

240Vac 65 65 65 65<br />

UL 480Vac 35 35 35 35<br />

600Vac 18 25 25 25<br />

240Vac 65/65 65/65 65/65 65/65<br />

IEC 415Vac 45/45 50/50 50/25 50/25<br />

(l CU /l CS )<br />

690Vac 12/6 20/10 20/10 20/10<br />

DC Voltages – Interrupting Rating (kA) d<br />

250Vdc - 2p 30 22 22 22<br />

500Vdc - 3p c 25 35 35 35<br />

Type H – High Interrupting Rating a , RMS Symmetrical Amperes (kA)<br />

240Vac 100 100 100 100<br />

UL 480Vac 65 65 65 65<br />

600Vac 18 35 35 35<br />

240Vac 100/75 100/75 100/75 100/50<br />

IEC 415Vac 70/70 70/70 70/35 70/35<br />

(l CU /l CS )<br />

690Vac 15/8 30/15 30/15 30/15<br />

DC Voltages – Interrupting Rating (kA) d<br />

250Vdc - 2p 30 25 25 25<br />

500Vdc - 3p c 35 50 50 50<br />

600Vdc - 3p e 65 65 65 65<br />

Type L – Very High Interrupting Rating a , RMS Symmetrical Amperes (kA)<br />

240Vac 200 200 200 200<br />

UL 480Vac 100 100 100 100<br />

600Vac 18 50 65 65<br />

240Vac 200/150 200/150 200/150 200/150<br />

IEC 415Vac 100/75 100/75 100/75 100/75<br />

(l CU /l CS )<br />

690Vac 15/8 35/17 35/17 35/17<br />

DC Voltages – Interrupting Rating (kA) d<br />

250Vdc - 2p 30 42 42 42<br />

500Vdc - 3p c 35 65 65 65<br />

a UL does not recognize AIC ratings for Molded Case<br />

Switches or Motor Circuit Protectors.<br />

b 25kA available in a special version. Standard breakers<br />

rated 18kA. See page 7-188.<br />

c 500Vdc nominal, 600Vdc max. for ungrounded DC UPS<br />

systems.<br />

d DC Interruption Ratings do not apply to electronic trip<br />

circuit breakers.<br />

e For 600 VDC breakers see page 7-204.<br />

Thermal-magnetic available non-interchangeable only.<br />

13.6” with extended shields.<br />

7-172<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


VL Circuit Breakers<br />

Trip Unit Overview<br />

Selection<br />

The interchangeability of the VL circuit<br />

breaker trip units allow for easy conversion<br />

from any of 3 types of protection.<br />

They are thermal-magnetic, electronic,<br />

or electronic with a built-in LCD. The<br />

thermal-magnetic trip unit features an<br />

adjustable magnetic trip setting. The<br />

electronic trip units are microprocessor<br />

based true RMS sensing devices and<br />

are available with a variety of adjustable<br />

trip settings, configurations, and information<br />

menus. With precise control<br />

over the circuit beaker functions and<br />

access to system status, diagnostics,<br />

and information, these trip units allow<br />

for unsurpassed flexibility in circuit<br />

coordination.<br />

An example of coordination is the out<br />

of the box Ground Fault function on the<br />

Model 555 trip units. The pick-up and<br />

time delay settings are set at the<br />

factory for each frame and do not<br />

overlap with the settings on the other<br />

frames. Therefore, when VL breakers<br />

are used together in a system the GF<br />

protection is automatically coordinated.<br />

The user also has the ability to program<br />

a custom coordination scheme with<br />

adjustable settings on both the 555 and<br />

586 trip units.<br />

VL Trip Units<br />

Trip Unit Functions<br />

Continuous Amps Rating (I r )<br />

This setting is the continuous current<br />

that the breaker will carry without tripping.<br />

It can be set up to 100% of the trip<br />

unit’s nominal rating (I n ).<br />

Long Time Delay (t r )<br />

Sometimes referred to as the “overload”<br />

position, this function controls the breaker‘s<br />

“pause-in-tripping” time. It allows<br />

low level, temporary inrush currents<br />

such as those encountered when starting<br />

a motor to pass without tripping. The<br />

time delay begins when the current<br />

reaches 6 x I r .<br />

Instantaneous Pick-up (I i )<br />

This function sets the breaker to trip<br />

instantaneously during high fault conditions.<br />

This function may be turned off on<br />

Model 586 trip units. Turning this function<br />

off will enable an instantaneous trip<br />

Model 525 Model 555 Model 586<br />

Thermalmagnetic<br />

Electronic<br />

LI<br />

Electronic<br />

LIG<br />

Electronic<br />

LSI<br />

Electronic<br />

LSIG<br />

override function to ensure self protection<br />

of circuit breaker.<br />

Short Time Pick-Up (l sd )<br />

This function controls the level of fault<br />

current the breaker will carry for a short<br />

time without tripping, thus allowing<br />

downstream devices to clear short circuits<br />

ahead of up-stream protection.<br />

It may be defeated (turned-off) on<br />

Model 586 trip units.<br />

Short Time Delay (t sd )<br />

This controls the interval of time the<br />

breaker will remain closed against a fault<br />

(at the Short Time Pick-up current level)<br />

without tripping. The time delay may be<br />

set at fixed points or at short time intervals<br />

based on l 2 t curves. This function is<br />

used with the Short Time Pick-up to<br />

achieve selectivity and better system<br />

coordination.<br />

Electronic<br />

with LCD<br />

LSI<br />

Electronic<br />

with LCD<br />

LSIG<br />

Electronic<br />

with LCD<br />

LSI + G alarm only<br />

Continuous Current Setting (I r ) Fixed u u u u u u u<br />

Long Time Delay (t r ) h u u u u u u u<br />

Instantaneous Function l l l l l (ON/OFF) (ON/OFF) (ON/OFF)<br />

Instantaneous Pickup (I i ) u u u u u u u u<br />

Short Time Function h h h l l (ON/OFF) (ON/OFF) (ON/OFF)<br />

Short Time Pick-up (I sd ) h h h u u u u u<br />

Short Time Delay (t sd ) h h h u u u u u<br />

Ground Fault Pick-up (I g ) h h u h u h u h<br />

Ground Fault Delay (t g ) h h u h u h u h<br />

Ground Fault Alarm Pick-up h h h h h h u u<br />

Ground Fault Alarm Delay h h h h h h u u<br />

Alarm & Status Indicator h l l l l l l l<br />

Built-in Display (LCD) h h h h h l l l<br />

Pre-Trip Alarm a h l l l l l l l<br />

Last Trip Information h l a l a l a l a l l l<br />

Zone Selective a h l l l l l l l<br />

Communications a h l l l l l l l<br />

u Adjustable setting<br />

l This feature is included<br />

h Feature is not included.<br />

a Requires a COMPRO20 or COMMOD21 module in a communication system.<br />

Ground Fault Pick-Up (I g )<br />

This setting controls the level of ground<br />

fault current that will cause the breaker<br />

to trip. Model 555 Electronic Trip Units<br />

act on the residual current to sense<br />

ground current. The Model 586<br />

Electronic Trip Unit is programmable<br />

and allows the user to select either<br />

the residual current method or direct<br />

detection (via a separate current transformer)<br />

to detect ground current.<br />

Ground Fault Time Delay (t g )<br />

This controls the interval of time the<br />

breaker will remain closed after a ground<br />

fault is detected (at the Ground Fault<br />

Pick-up current level) without tripping.<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-173


VL Circuit Breakers<br />

General Information<br />

Selection<br />

Thermal-Magnetic trip units, Model 525, combine the inverse time element design for low level overloads, and instantaneous<br />

magnetic action for short circuit protection. The standard unit has preset overload protection and an adjustable instantaneous trip<br />

setting, with 6 set points. Thermal-Magnetic trip units are available throughout the VL family, from 50 to 1600A.<br />

Electronic Trip Units<br />

Electronic trip units are available through<br />

the VL family, from 60A (which can be<br />

set as low as 30A) up through 1600A.<br />

They are also available in four trip<br />

configurations (LI, LIG, LSI, LSIG) and<br />

features can include a built-in LCD<br />

display.<br />

On the Model 555 Electronic Trip Unit a<br />

flashing LED confirms that the<br />

microprocessor is in operating and<br />

another indicates an overload condition.<br />

For ease-of-use and to insure proper<br />

coordination, the set points for the<br />

continuous current are shown on the<br />

face of these trip units in amps.<br />

On the Model 586, the LCD version, the<br />

current in each phase is continuously<br />

shown on the display. Unlike many<br />

displays, no secondary or auxiliary voltage<br />

is required as long as the breaker is<br />

energized and a minimal load current is<br />

present. These trip units can also indicate<br />

the “last trip” status (date, time,<br />

amps) when they‘re connected to a PC<br />

via one of our communications modules.<br />

Without being connected via a communication<br />

module, the last trip status can be<br />

viewed on Model 586 trip units (no time<br />

stamp).<br />

Typical Trip Unit Labeling and Adjustment Positions<br />

Model 555 Electronic Trip Unit<br />

with LSIG trip functions<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Model 586 Electronic Trip Unit<br />

has an LCD display<br />

7-174<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


VL Circuit Breakers<br />

DG 150A Frame, VL Series<br />

Selection<br />

Ordering Information<br />

Complete Assembled Breaker<br />

A complete factory assembled DG breaker includes the frame, trip unit, and<br />

standard line and load connectors, all factory installed and shipped as a complete<br />

breaker. Assembled breakers are only available with standard<br />

connectors.<br />

For DC applications, use thermal magnetic trip unit only.<br />

Breakers are suitable for reverse feed applications.<br />

For special applications, refer to page 7-222.<br />

Mounting hardware is included with each frame or complete breaker.<br />

For 100% rated breakers with a non-interchangeable trip unit, change the 3rd<br />

character of the catalog number to “W”. Available in electronic and electronic<br />

with LCD only.<br />

HACR rated.<br />

Interrupting Ratings<br />

Interrupting<br />

Class<br />

Breaker<br />

Type<br />

Connectors for 75°C Wire<br />

RMS Symmetrical Amperes (KA)<br />

UL 489 IEC 60947-2<br />

Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz)<br />

600Y<br />

220/240 380/415 690<br />

240 480 /347 250 500<br />

Ampere Wire No. of cables<br />

Construction Rating Range per connector Catalog Number<br />

Steel 30-150 #8–1/0 Cu 1 3TW1DG20 b<br />

Aluminum 30-150 #6–3/0 Al/Cu 1 3TA1DG30 <br />

Copper 30-150 #6–3/0 Cu 1 3TC1DG30 b<br />

Distribution Lugs<br />

30-150 #14–#2 Al/Cu (3pcs. Max) 3 3TA3DG02 b<br />

30-150 #14–#4 Cu, #14–#6 Al 6 3TA6DG04 b<br />

Compression Lugs<br />

30-150 #14–2/0 kcmil Al/Cu – 2CLD20 c<br />

30-150 #14–2/0 kcmil Al/Cu – 3CLD20 b<br />

a Standard connector supplied with complete breakers.<br />

b Kit consists of 3 terminal connectors.<br />

c 2 Lugs for 2-pole breakers.<br />

d Required for 100% rated DG breakers. Requires 90°C Cu cable sized at 75°C ampacity<br />

ICU ICS ICU ICS ICU ICS<br />

N NDGB 65 35 18 30 18 65 65 40 40 12 6<br />

H HDGB 100 65 18 30 18 100 75 70 70 12 6<br />

L LDGB 200 100 18 30 18 200 150 100 75 12 6<br />

Dimensions, inches (mm)<br />

Number<br />

To Handle<br />

of Poles Width Length Depth D1<br />

2, 3 4.1 (105) 6.9 (175) 3.4 (81) 4.2(107)<br />

Approx. Shipping Weight, lbs. (kg)<br />

Trip Unit Complete<br />

Poles Frame Thermal-Mag. Electronic Breaker<br />

2, 3 3.7 (1.7) 2.2 (1.0) 2.6 (1.2) 5.9 (2.7)<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

DG Thermal-Magnetic, Instantaneous<br />

Trip Adjustment Range<br />

Instantaneous<br />

Trip Unit Continuous Overcurrent Setting (I i)<br />

Amp Rating (I n ) Min. Max.<br />

50 450 600<br />

60 450 600<br />

70 450 700<br />

80 450 800<br />

90 500 1000<br />

100 500 1000<br />

110 550 1100<br />

125 625 1250<br />

150 800 1600<br />

Note: Each breaker has 6 trip settings in this range. External Accessories pages 7-205 through 7-217<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-175


VL Circuit Breakers<br />

DG 150A Thermal-Magnetic Trip Unit<br />

Selection<br />

I i<br />

AMPS<br />

1120 1280<br />

960<br />

1440<br />

800 1600<br />

I n =150A<br />

40? C<br />

TM ~<br />

TRIP UNIT/DISPARADOR 525<br />

Type / Tipo CDT3<br />

Cat. No. - CDT3B150<br />

Model 525 Trip Unit<br />

DG 150A Frame 2-Pole with Thermal-Magnetic Trip Unit<br />

COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER<br />

Continuous<br />

Ampere Rating<br />

N-Interrupting Class<br />

Catalog Number<br />

H-Interrupting Class<br />

Catalog Number<br />

L-Interrupting Class<br />

Catalog Number<br />

50 NDK2B050L HDK2B050L LDK2B050L<br />

60 NDK2B060L HDK2B060L LDK2B060L<br />

70 NDK2B070L HDK2B070L LDK2B070L<br />

80 NDK2B080L HDK2B080L LDK2B080L<br />

90 NDK2B090L HDK2B090L LDK2B090L<br />

100 NDK2B100L HDK2B100L LDK2B100L<br />

110 NDK2B110L HDK2B110L LDK2B110L<br />

125 NDK2B125L HDK2B125L LDK2B125L<br />

150 NDK2B150L HDK2B150L LDK2B150L<br />

DG 150A Frame 3-Pole with Thermal-Magnetic Trip Unit<br />

COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Continuous<br />

Ampere Rating<br />

N-Interrupting Class<br />

Catalog Number<br />

H-Interrupting Class<br />

Catalog Number<br />

L-Interrupting Class<br />

Catalog Number<br />

50 NDK3B050L HDK3B050L LDK3B050L<br />

60 NDK3B060L HDK3B060L LDK3B060L<br />

70 NDK3B070L HDK3B070L LDK3B070L<br />

80 NDK3B080L HDK3B080L LDK3B080L<br />

90 NDK3B090L HDK3B090L LDK3B090L<br />

100 NDK3B100L HDK3B100L LDK3B100L<br />

110 NDK3B110L HDK3B110L LDK3B110L<br />

125 NDK3B125L HDK3B125L LDK3B125L<br />

150 NDK3B150L HDK3B150L LDK3B150L<br />

7-176<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


VL Circuit Breakers<br />

DG 150A Electronic Trip Units<br />

Selection<br />

Model 555 Trip Units<br />

DG 150A Frame 3-Pole Electronic Trip Unit a<br />

COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER<br />

Continuous<br />

Ampere Rating<br />

N-Interrupting Class<br />

Catalog Number<br />

H-Interrupting Class<br />

Catalog Number<br />

L-Interrupting Class<br />

Catalog Number<br />

ELECTRONIC LI TRIP<br />

60 NDK3R060L HDK3R060L LDK3R060L<br />

100 NDK3R100L HDK3R100L LDK3R100L<br />

150 NDK3R150L HDK3R150L LDK3R150L<br />

ELECTRONIC LSI TRIP<br />

60 NDK3T060L HDK3T060L LDK3T060L<br />

100 NDK3T100L HDK3T100L LDK3T100L<br />

150 NDK3T150L HDK3T150L LDK3T150L<br />

ELECTRONIC LSIG TRIP<br />

60 NDK3V060L HDK3V060L LDK3V060L<br />

100 NDK3V100L HDK3V100L LDK3V100L<br />

150 NDK3V150L HDK3V150L LDK3V150L<br />

ELECTRONIC LIG TRIP<br />

60 NDK3W060L HDK3W060L LDK3W060L<br />

100 NDK3W100L HDK3W100L LDK3W100L<br />

150 NDK3W150L HDK3W150L LDK3W150L<br />

7<br />

DG 150A Frame 3-Pole Electronic LCD Trip Unit a<br />

COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER<br />

Model 586 Trip Unit<br />

Continuous<br />

Ampere Rating<br />

N-Interrupting Class<br />

Catalog Number<br />

H-Interrupting Class<br />

Catalog Number<br />

L-Interrupting Class<br />

Catalog Number<br />

LCD ELECTRONIC LSI TRIP<br />

60 NDK3A060L HDK3A060L LDK3A060L<br />

100 NDK3A100L HDK3A100L LDK3A100L<br />

150 NDK3A150L HDK3A150L LDK3A150L<br />

LCD ELECTRONIC LSIG TRIP<br />

60 NDK3G060L HDK3G060L LDK3G060L<br />

100 NDK3G100L HDK3G100L LDK3G100L<br />

150 NDK3G150L HDK3G150L LDK3G150L<br />

LCD ELECTRONIC LSI TRIP + GF ALARM ONLY<br />

60 NDK3K060L HDK3K060L LDK3K060L<br />

100 NDK3K100L HDK3K100L LDK3K100L<br />

150 NDK3K150L HDK3K150L LDK3K150L<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

a Due to the location of the magnetic tripping solenoid, the<br />

left accessory pocket is not available for accessories.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-177


VL Circuit Breakers<br />

Internal Accessories for DG 150A and FG 250A Frames<br />

Selection<br />

Auxiliary Switch and Alarm Switch Combination Kits<br />

Description Mounting Pocket a Catalog Number<br />

1 Alarm Switch<br />

1A/B c Left, Right b ASKL1<br />

Bases AMBL2 & AMBL3<br />

2 Aux. Switches<br />

1A + 1B Left, Right ASKL2<br />

Bases AMBL1<br />

2 Aux. + 1 Alarm Switch<br />

1A + 1B, 1A/B c Left, Right b ASKL3<br />

Bases AMBL2 & AMBL3<br />

Auxiliary/Alarm Switch Mounting Base Only<br />

Description Mounting Pocket Catalog Number<br />

Up to 3 Auxiliary Switches Left, Right AMBL1<br />

2 Aux. + 1 Alarm Switch Left Pocket Only AMBL2<br />

2 Aux. + 1 Alarm Switch Right Pocket Only AMBL3<br />

Auxiliary/Alarm Switch Only<br />

Common to DG - PG Frames<br />

Description<br />

Catalog Number<br />

1 Normally Open Contact (1A) ASWPA<br />

1 Normally Closed Contact (1B) ASWPB<br />

Shunt Trips<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Description Mounting Pocket Catalog Number<br />

24 VDC STRLB24DC<br />

48-60 VDC STRLC60DC<br />

110-127 VDC STRLD125DC<br />

220-250 VDC Right Pocket Only STRLE250DC<br />

48-60 VAC STRLM60<br />

110-127 VAC STRLN120<br />

208-277 VAC STRLS277<br />

380-600 VAC STRLV600<br />

Undervoltage Release<br />

Description Mounting Pocket Catalog Number<br />

12 VDC UVRLA12DC<br />

24 VDC UVRLB24DC<br />

48 VDC UVRLC48DC<br />

60 VDC UVRLG60DC<br />

110-127 VDC UVRLD125DC<br />

220-250 VDC UVRLE250DC<br />

24 VAC Right Pocket Only UVRLL24<br />

110-127 VAC UVRLN120<br />

220-240 VAC UVRLR240<br />

208 VAC UVRLP208<br />

277 VAC UVRLS277<br />

380-415 VAC UVRLT415<br />

440-480 VAC UVRLU480<br />

UVRLN120<br />

a Refer to the “Accessory Locations” chart on page 7-218 for guidelines and limitations about which pockets may be used for<br />

accessory combinations.<br />

b These kits include two bases, one for mounting switches in the left pocket and another for mounting in the right.<br />

c Includes 1A and 1B contact for alarm purposes, only one of which may be installed at any time.<br />

‘A’ refers to a normally open contact (open when the breaker contacts are open).<br />

‘B’ refers to a normally closed contact (closed when the breaker contacts are open).<br />

External Accessories pages 7-205 through 7-217<br />

7-178<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


VL Circuit Breakers<br />

FG 250A Frame, VL Series<br />

Selection/Dimensions<br />

Ordering Information<br />

Complete Assembled Breaker<br />

A complete factory assembled FG breaker includes the frame, trip unit,<br />

and standard line and load connectors, all factory installed and shipped as<br />

a complete breaker. Assembled breakers are available only with standard<br />

connectors.<br />

For DC applications, use thermal magnetic trip unit only.<br />

Breakers are suitable for reverse feed applications.<br />

For special applications, refer to page 7-222.<br />

Mounting hardware is included with each frame or complete breaker.<br />

HACR rated.<br />

Interrupting Ratings<br />

To RMS Symmetrical Amperes (KA)<br />

50-250 #14–#4 Cu/Al 6 3TA6FG04 <br />

UL 489 IEC 60947-2<br />

Number<br />

of Poles Width Length Depth<br />

Handle<br />

D1<br />

Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz)<br />

Breaker 600Y/ 220/240 380/415 690<br />

2, 3 4.1 (105) 6.9 (175) 3.4 (81) 4.2 (107)<br />

Type 240 480 347 250 500 ICU ICS ICU ICS ICU ICS<br />

NFG 65 35 18 30 18 65 65 40 40 12 6<br />

HFG 100 65 18 30 18 100 75 70 70 12 6 Shipping Weight, lbs. (kg)<br />

LFG 200 100 18 30 18 200 150 100 75 12 6<br />

Trip Unit Complete<br />

Connectors for 75°C Wire<br />

Poles Frame Thermal-Mag. Electronic Breaker<br />

2, 3 4.0 (1.8) 2.2 (1.0) 2.6 (1.2) 6.2 (2.8)<br />

Ampere Wire No. of cables Catalog<br />

Construction Rating Range per connector Number<br />

Steel 50-250 #4–350 kcmil Cu 1 3TW1FG350 <br />

Aluminum 50-250 #4–350 kcmil Al/Cu 1 3TAW1FG350 <br />

Copper 50-250 #4–350 kcmil Cu 1 3TCW1FG350 <br />

Distribution Lugs<br />

50-250 #12–2/0 Cu/Al 3 3TA3FG20 <br />

Standard connector supplied with complete breakers.<br />

Kit consists of 3 terminal connectors.<br />

2 Lugs for 2-pole breakers.<br />

3 Lugs for 3-pole breakers.<br />

FG Thermal-Magnetic,<br />

Instantaneous Trip<br />

Adjustment Range<br />

Instantaneous<br />

Trip Unit Continuous Overcurrent Setting (I i)<br />

Amp Rating (I n ) Min. Max.<br />

100 625 1250<br />

110 800 1600<br />

125 800 1600<br />

150 800 1600<br />

175 1000 2000<br />

200 1000 2000<br />

225 1250 2500<br />

250 1250 2500<br />

Note: Each breaker has 6 trip settings in this range.<br />

Dimensions, inches (mm)<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

External Accessories pages 7-205 through 7-217<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-179


VL Circuit Breakers<br />

FG 250A Thermal-Magnetic Trip Unit<br />

Selection<br />

I i<br />

AMPS<br />

1750 2000<br />

1500<br />

2250<br />

1250 2500<br />

I n =250A<br />

40? C<br />

TM ~<br />

TRIP UNIT/DISPARADOR 525<br />

Type / Tipo CFT3<br />

Cat. No. - CFT3B250<br />

Model 525 Trip Unit<br />

FG 250A Frame 2-Pole with Thermal-Magnetic Trip Unit<br />

COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER<br />

Continuous<br />

Ampere Rating<br />

N-Interrupting Class<br />

Catalog Number<br />

H-Interrupting Class<br />

Catalog Number<br />

L-Interrupting Class<br />

Catalog Number<br />

100 NFK2B100L HFK2B100L LFK2B100L<br />

110 NFK2B110L HFK2B110L LFK2B110L<br />

125 NFK2B125L HFK2B125L LFK2B125L<br />

150 NFK2B150L HFK2B150L LFK2B150L<br />

175 NFK2B175L HFK2B175L LFK2B175L<br />

200 NFK2B200L HFK2B200L LFK2B200L<br />

225 NFK2B225L HFK2B225L LFK2B225L<br />

250 NFK2B250L HFK2B250L LFK2B250L<br />

FG 250A Frame 3-Pole with Thermal-Magnetic Trip Unit<br />

COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

0<br />

Continuous<br />

Ampere Rating<br />

N-Interrupting Class<br />

Catalog Number<br />

H-Interrupting Class<br />

Catalog Number<br />

L-Interrupting Class<br />

Catalog Number<br />

100 NFK3B100L HFK3B100L LFK3B100L<br />

110 NFK3B110L HFK3B110L LFK3B110L<br />

125 NFK3B125L HFK3B125L LFK3B125L<br />

150 NFK3B150L HFK3B150L LFK3B150L<br />

175 NFK3B175L HFK3B175L LFK3B175L<br />

200 NFK3B200L HFK3B200L LFK3B200L<br />

225 NFK3B225L HFK3B225L LFK3B225L<br />

250 NFK3B250L HFK3B250L LFK3B250L<br />

7-180<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


VL Circuit Breakers<br />

FG 250A Electronic Trip Units<br />

Selection<br />

Model 555 Trip Units<br />

FG 250A Frame 3-Pole Electronic Trip Unit a<br />

COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER<br />

Continuous<br />

Ampere Rating<br />

N-Interrupting Class<br />

Catalog Number<br />

H-Interrupting Class<br />

Catalog Number<br />

L-Interrupting Class<br />

Catalog Number<br />

ELECTRONIC LI TRIP<br />

100 NFK3R100L HFK3R100L LFK3R100L<br />

150 NFK3R150L HFK3R150L LFK3R150L<br />

250 NFK3R250L HFK3R250L LFK3R250L<br />

ELECTRONIC LSI TRIP<br />

100 NFK3T100L HFK3T100L LFK3T100L<br />

150 NFK3T150L HFK3T150L LFK3T150L<br />

250 NFK3T250L HFK3T250L LFK3T250L<br />

ELECTRONIC LSIG TRIP<br />

100 NFK3V100L HFK3V100L LFK3V100L<br />

150 NFK3V150L HFK3V150L LFK3V150L<br />

250 NFK3V250L HFK3V250L LFK3V250L<br />

ELECTRONIC LIG TRIP<br />

100 NFK3W100L HFK3W100L LFK3W100L<br />

150 NFK3W150L HFK3W150L LFK3W150L<br />

250 NFK3W250L HFK3W250L LFK3W250L<br />

7<br />

FG 250A Frame 3-Pole Electronic LCD Trip Unit a<br />

COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER<br />

Model 586 Trip Unit<br />

Continuous<br />

Ampere Rating<br />

N-Interrupting Class<br />

Catalog Number<br />

H-Interrupting Class<br />

Catalog Number<br />

L-Interrupting Class<br />

Catalog Number<br />

LCD ELECTRONIC LSI TRIP<br />

100 NFK3A100L HFK3A100L LFK3A100L<br />

150 NFK3A150L HFK3A150L LFK3A150L<br />

250 NFK3A250L HFK3A250L LFK3A250L<br />

LCD ELECTRONIC LSIG TRIP<br />

100 NFK3G100L HFK3G100L LFK3G100L<br />

150 NFK3G150L HFK3G150L LFK3G150L<br />

250 NFK3G250L HFK3G250L LFK3G250L<br />

LCD ELECTRONIC LSI TRIP + GF ALARM ONLY<br />

100 NFK3K100L HFK3K100L LFK3K100L<br />

150 NFK3K150L HFK3K150L LFK3K150L<br />

250 NFK3K250L HFK3K250L LFK3K250L<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

a Due to the location of the magnetic tripping solenoid, the<br />

left accessory pocket is not available for accessories.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-181


VL Circuit Breakers<br />

Internal Accessories for DG 150A and FG 250A Frames<br />

Selection<br />

Auxiliary Switch and Alarm Switch Combination Kits<br />

Description Mounting Pocket a Catalog Number<br />

1 Alarm Switch<br />

1A/B c Left, Right b ASKL1<br />

Bases AMBL2 & AMBL3<br />

2 Aux. Switches<br />

1A + 1B Left, Right ASKL2<br />

Bases AMBL1<br />

2 Aux. + 1 Alarm Switches<br />

1A + 1B, 1A/B c Left, Right b ASKL3<br />

Bases AMBL2 & AMBL3<br />

Auxiliary/Alarm Switch Mounting Base Only<br />

Description Mounting Pocket Catalog Number<br />

Up to 3 Auxiliary Switches Left, Right AMBL1<br />

2 Aux. + 1 Alarm Switch Left Pocket Only AMBL2<br />

2 Aux. + 1 Alarm Switch Right Pocket Only AMBL3<br />

Auxiliary/Alarm Switch Only<br />

Common to DG - PG Frames<br />

Description<br />

Catalog Number<br />

1 Normally Open Contact (1A) ASWPA<br />

1 Normally Closed Contact (1B) ASWPB<br />

Shunt Trips<br />

7<br />

Description Mounting Pocket Catalog Number<br />

24 VDC STRLB24DC<br />

48-60 VDC STRLC60DC<br />

110-127 VDC STRLD125DC<br />

220-250 VDC Right Pocket Only STRLE250DC<br />

48-60 VAC STRLM60<br />

110-127 VAC STRLN120<br />

208-277 VAC STRLS277<br />

380-600 VAC STRLV600<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Undervoltage Release<br />

Description Mounting Pocket Catalog Number<br />

12 VDC UVRLA12DC<br />

24 VDC UVRLB24DC<br />

48 VDC UVRLC48DC<br />

60 VDC UVRLG60DC<br />

110-127 VDC UVRLD125DC<br />

220-250 VDC UVRLE250DC<br />

24 VAC Right Pocket Only UVRLL24<br />

110-127 VAC UVRLN120<br />

220-240 VAC UVRLR240<br />

208 VAC UVRLP208<br />

277 VAC UVRLS277<br />

380-415 VAC UVRLT415<br />

440-480 VAC UVRLU480<br />

UVRLN120<br />

a Refer to the “Accessory Locations” chart on page 7-218 for guidelines and limitations about which pockets may be<br />

used for accessory combinations.<br />

b These kits include two bases, one for mounting switches in the left pocket and another for mounting in the right.<br />

c Includes 1A and 1B contact for alarm purposes, only one of which may be installed at any time.<br />

‘A’ refers to a normally open contact (open when the breaker contacts are open).<br />

‘B’ refers to a normally closed contact (closed when the breaker contacts are open).<br />

External Accessories pages 7-205 through 7-217<br />

7-182<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


VL Circuit Breakers<br />

JG 400A Frame, VL Series<br />

Selection/Dimensions<br />

Ordering Information<br />

Complete Assembled Breaker<br />

A complete factory assembled JG breaker includes the frame, trip unit,<br />

and standard line and load connectors, all factory installed and shipped<br />

as a complete breaker. Assembled breakers are available only with<br />

standard connectors.<br />

For any other configuration, order the frame, trip unit, and terminals as<br />

separate items.<br />

For DC applications, use thermal magnetic trip unit only.<br />

For reverse feed applications, select non-interchangeable trip breakers only.<br />

For non-interchangeable trip breakers, change the third digit of the catalog<br />

number to “X” for standard breakers.<br />

For 100% rated breakers with a non-interchangeable trip unit, change the 3 rd<br />

character of the catalog number to ”Y“ (3-pole only).<br />

For special applications, refer to page 7-222.<br />

Mounting hardware is included with each frame or complete breaker.<br />

Dimensions, inches (mm)<br />

HACR rated. Number To Handle<br />

of Poles Width Length Depth D1<br />

2, 3 5.5 (139) 11 (279) 4.2 (102) 5.4 (138)<br />

Interrupting Ratings<br />

Interrupting<br />

Class<br />

Breaker<br />

Type<br />

RMS Symmetrical Amperes (KA)<br />

UL 489 AIR (File E10848) IEC 60947-2<br />

Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz)<br />

220/240 380/415 690<br />

240 480 600 250 500<br />

ICU ICS ICU ICS ICU ICS<br />

N NJGA 65 35 25 30 25 65 65 45 45 12 6<br />

H HJGA 100 65 25 30 35 100 75 70 70 15 8<br />

L LJGA 200 100 25 30 35 200 150 100 75 15 8<br />

Shipping Weight, lbs. (kg)<br />

Trip Unit Complete<br />

Poles Frame Thermal-Mag. Electronic Breaker<br />

2, 3 9.3 (4.2) 4.0 (1.8) 4.0 (1.8) 12.6 (5.7)<br />

Connectors for 75°C Wire<br />

Ampere Wire No. of cables<br />

Construction Rating Range per connector Catalog Number<br />

Steel 70-400 1/0–600 kcmil Cu 1 3TW1JG600 b<br />

Aluminum 70-400 3/0–250 kcmil Al/Cu 2 3TA2JG250 ab<br />

Aluminum 70-400 250–750 kcmil Al 1 3TA1JG750 b<br />

Aluminum 70-400 3/0–600 kcmil Cu 1 3TA1JG750 b<br />

Copper 70-400 3/0–600 kcmil Cu 1 TC1JG750 <br />

Copper 70-400 3/0–250 kcmil Cu 2 TC2JG250 <br />

Distribution Lugs<br />

70-400 #14–4 Cu 12 3TA12JG04 b<br />

70-400 #14–2/0 Al/Cu 6 3TA6JG20 b<br />

Compression Lugs<br />

70-400 #6–350 kcmil — 3CLJ350 b<br />

70-400 250-600 kcmil — 3CLJ600 b<br />

a Standard construction supplied for each breaker.<br />

b Kit consists of 3 terminal connectors.<br />

c Required for 100% rated JG breakers. Requires 90°C Cu<br />

cable sized at 75°C ampacity.<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

JG Thermal-Magnetic,<br />

Instantaneous<br />

Trip Adjustment Range<br />

Instantaneous<br />

Trip Unit Continuous Overcurrent Setting (I i)<br />

Amp Rating (I n ) Min. Max.<br />

250 1250 2500<br />

300 1500 3000<br />

350 1750 3500<br />

400 2000 4000<br />

Note: Each breaker has 6 trip settings in this range.<br />

External Accessories pages 7-205 through 7-217<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-183


VL Circuit Breakers<br />

JG 400A Thermal-Magnetic Trip Unit<br />

Selection<br />

JG 400A Frame 2-Pole with Thermal-Magnetic Trip Unit<br />

Model 525 Trip Unit<br />

N-Interrupting Class H-Interrupting Class L-Interrupting Class<br />

Catalog Number Catalog Number Catalog Number Catalog Number<br />

FRAME ONLY<br />

Continuous<br />

NJG2F400 HJG2F400 LJG2F400<br />

Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY<br />

250 NJG2B250L HJG2B250L LJG2B250L CJT2B250<br />

300 NJG2B300L HJG2B300L LJG2B300L CJT2B300<br />

350 NJG2B350L HJG2B350L LJG2B350L CJT2B350<br />

400 NJG2B400L HJG2B400L LJG2B400L CJT2B400<br />

JG 400A Frame 3-Pole with Thermal-Magnetic Trip Unit<br />

N-Interrupting Class H-Interrupting Class L-Interrupting Class<br />

Catalog Number Catalog Number Catalog Number Catalog Number<br />

FRAME ONLY<br />

Continuous<br />

NJG3F400 HJG3F400 LJG3F400<br />

Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY<br />

250 NJG3B250L HJG3B250L LJG3B250L CJT3B250<br />

300 NJG3B300L HJG3B300L LJG3B300L CJT3B300<br />

350 NJG3B350L HJG3B350L LJG3B350L CJT3B350<br />

400 NJG3B400L HJG3B400L LJG3B400L CJT3B400<br />

7<br />

JJ 400A Frame 240V max., 2-pole with<br />

Thermal-Magnetic Non-Interchangeable Trip Unit <br />

N-Interrupting Class<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Continuous<br />

Ampere Rating<br />

Catalog Number<br />

COMPLETE BREAKER<br />

250 NJJ2B250<br />

300 NJJ2B300<br />

350 NJJ2B350<br />

400 NJJ2B400<br />

JJ 400A Frame 240V max., 3-pole with<br />

Thermal-Magnetic Non-Interchangeable Trip Unit <br />

Continuous<br />

Ampere Rating<br />

N-Interrupting Class<br />

Catalog Number<br />

COMPLETE BREAKER<br />

250 NJJ3B250<br />

300 NJJ3B300<br />

350 NJJ3B350<br />

400 NJJ3B400<br />

Terminal connectors must be ordered separately.<br />

Breaker Type NJJA.<br />

7-184<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


VL Circuit Breakers<br />

JG 400A Electronic Trip Units<br />

Selection<br />

Model 555 Trip Units<br />

JG 400A Frame 3-Pole Electronic Trip Unit<br />

N-Interrupting Class H-Interrupting Class L-Interrupting Class<br />

Catalog Number Catalog Number Catalog Number Catalog Number<br />

FRAME ONLY<br />

Continuous<br />

NJG3F400 HJG3F400 LJG3F400<br />

Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY<br />

ELECTRONIC LI TRIP<br />

250 NJG3R250L HJG3R250L LJG3R250L CJT3R250<br />

400 NJG3R400L HJG3R400L LJG3R400L CJT3R400<br />

ELECTRONIC LSI TRIP<br />

250 NJG3T250L HJG3T250L LJG3T250L CJT3T250<br />

400 NJG3T400L HJG3T400L LJG3T400L CJT3T400<br />

ELECTRONIC LSIG TRIP<br />

250 NJG3V250L HJG3V250L LJG3V250L CJT3V250<br />

400 NJG3V400L HJG3V400L LJG3V400L CJT3V400<br />

ELECTRONIC LIG TRIP<br />

250 NJG3W250L HJG3W250L LJG3W250L CJT3W250<br />

400 NJG3W400L HJG3W400L LJG3W400L CJT3W400<br />

7<br />

JG 400A Frame 3-Pole Electronic LCD Trip Unit<br />

Model 586 Trip Unit<br />

N-Interrupting Class H-Interrupting Class L-Interrupting Class<br />

Catalog Number Catalog Number Catalog Number Catalog Number<br />

FRAME ONLY<br />

Continuous<br />

NJG3F400 HJG3F400 LJG3F400<br />

Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY<br />

LCD ELECTRONIC LSI TRIP<br />

250 NJG3A250L HJG3A250L LJG3A250L CJT3A250<br />

400 NJG3A400L HJG3A400L LJG3A400L CJT3A400<br />

LCD ELECTRONIC LSIG TRIP<br />

250 NJG3G250L HJG3G250L LJG3G250L CJT3G250<br />

400 NJG3G400L HJG3G400L LJG3G400L CJT3G400<br />

LCD ELECTRONIC LSI TRIP + GF ALARM ONLY<br />

250 NJG3K250L HJG3K250L LJG3K250L CJT3K250<br />

400 NJG3K400L HJG3K400L LJG3K400L CJT3K400<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-185


VL Circuit Breakers<br />

Internal Accessories for JG 400A and LG 600A Frames<br />

Selection<br />

Auxiliary Switch and Alarm Switch Combination Kits<br />

Description Mounting Pocket a Catalog Number<br />

1 Alarm Switch<br />

1A/B c Left, Right b ASKL1<br />

Bases AMBL2 & AMBL3<br />

2 Aux. Switches<br />

1A + 1B Left, Right ASKL2<br />

Bases AMBL1<br />

2 Aux. + 1 Alarm Switches<br />

1A + 1B, 1A/B Left, Right b ASKL3<br />

Bases AMBL2 & AMBL3<br />

Auxiliary/Alarm Switch Mounting Base Only<br />

Description Mounting Pocket Catalog Number<br />

Up to 3 Auxiliary Switches Left, Right AMBL1<br />

2 Aux. + 1 Alarm Switch Left Pocket Only AMBL2<br />

2 Aux. + 1 Alarm Switch Right Pocket Only AMBL3<br />

Auxiliary/Alarm Switch Only<br />

Common to DG - PG Frames<br />

Description<br />

Catalog Number<br />

1 Normally Open Contact (1A) ASWPA<br />

1 Normally Closed Contact (1B) ASWPB<br />

Shunt Trips<br />

Description Mounting Pocket Catalog Number<br />

24 VDC STRLB24DC<br />

48-60 VDC STRLC60DC<br />

110-127 VDC STRLD125DC<br />

220-250 VDC Right Pocket Only STRLE250DC<br />

48-60 VAC STRLM60<br />

110-127 VAC STRLN120<br />

208-277 VAC STRLS277<br />

380-600 VAC STRLV600<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Undervoltage Release<br />

Description Mounting Pocket Catalog Number<br />

12 VDC UVRLA12DC<br />

24 VDC UVRLB24DC<br />

48 VDC UVRLC48DC<br />

60 VDC UVRLG60DC<br />

110-127 VDC UVRLD125DC<br />

220-250 VDC UVRLE250DC<br />

24 VAC Right Pocket Only UVRLL24<br />

110-127 VAC UVRLN120<br />

220-240 VAC UVRLR240<br />

208 VAC UVRLP208<br />

277 VAC UVRLS277<br />

380-415 VAC UVRLT415<br />

440-480 VAC UVRLU480<br />

UVRLN120<br />

a Refer to the “Accessory Locations” chart on page 7-218 for guidelines and limitations about which<br />

pockets may be used for accessory combinations.<br />

b Includes 1A and 1B contact for alarm purposes, only one of which may be installed at any time.<br />

‘A’ refers to a normally open contact (open when the breaker contacts are open).<br />

‘B’ refers to a normally closed contact (closed when the breaker contacts are open). External Accessories pages 7-205 through 7-217<br />

7-186<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


VL Circuit Breakers<br />

LG 600A Frame, VL Series<br />

Selection/Dimensions<br />

Ordering Information<br />

Complete Assembled Breaker<br />

A complete factory assembled LG breaker includes the frame, trip unit, and<br />

standard line and load lugs, all factory installed and shipped as a complete<br />

breaker. Assembled breakers are available only with standard connectors.<br />

For DC applications, use thermal magnetic trip unit only.<br />

Breakers are suitable for reverse feed applications.<br />

For special applications, refer to page 7-222.<br />

Mounting hardware is included with each breaker.<br />

For 100% rated breakers, change the 3rd character of the catalog number to<br />

“W”. Available on 400/500 Amp only (3-pole only).<br />

HACR rated.<br />

Interrupting Ratings<br />

RMS Symmetrical Amperes (KA)<br />

UL 489 IEC 60947-2<br />

Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz)<br />

Interrupting Breaker<br />

220/240 380/415 690<br />

Class Type 240 480 600 250 500<br />

ICU ICS ICU ICS ICU ICS<br />

N NLGB 65 35 18 30 25 65 65 45 45 12 6<br />

H HLGB 100 65 18 30 35 100 75 70 70 15 8<br />

L LLGB 200 100 18 30 35 200 150 100 75 15 8<br />

Special 600Vac 25kA thermal-magnetic version (Type HLGC) available, see page 7-188.<br />

Connectors for 75°C Wire<br />

Ampere Wire No. of cables<br />

Construction Rating Range per connector Catalog Number<br />

Aluminum 150-600 #2–600 kcmil Al/Cu 2 (load side) 3TA2LG600LD <br />

Aluminum 150-600 #2–600 kcmil Al/Cu 2 (line side) 3TA2LG600LN <br />

Copper 150-600 #2–600 kcmil Cu 2 (load side) 3TC2LG600LD <br />

Copper 150-600 #2–600 kcmil Cu 2 (line side) 3TC2LG600LN <br />

Compression Lugs<br />

150-600 #6–350 kcmil Al/Cu — 6CLL350 <br />

150-600 250-750 kcmil Al/Cu — 3CLL750 <br />

150-600 250-600 kcmil Al/Cu — 6CLL600 <br />

Standard construction supplied for each breaker.<br />

Kit consists of 3 terminal connectors.<br />

Kit consists of 6 lugs for Line or Load end.<br />

Required for 100% rated LG breakers. Requires 90°C Cu cable sized at 75°C ampacity.<br />

LG Thermal-Magnetic,<br />

Instantaneous<br />

Trip Adjustment Range<br />

Instantaneous<br />

Trip Unit Continuous Overcurrent Setting (I i)<br />

Amp Rating (I n ) Min. Max.<br />

400 2000 4000<br />

500 2500 5000<br />

600 2750 5500<br />

Note: Each breaker has 6 trip settings.<br />

Dimensions, inches (mm)<br />

Number<br />

To Handle<br />

of Poles Width Length Depth D1<br />

2, 3 5.5 (139) 11 (279) 4.2 (102) 5.4 (138)<br />

Ext. 13.6<br />

Shield (345.5)<br />

Shipping Weight, lbs. (kg)<br />

Trip Unit Complete<br />

Poles Frame Thermal-Mag. Electronic Breaker<br />

2, 3 17.4 (7.9) 3.5 (1.6) 4.2 (1.9) 20.9 (9.5)<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

External Accessories pages 7-205 through 7-217<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-187


VL Circuit Breakers<br />

LG 600A Thermal-Magnetic Trip Unit<br />

Selection<br />

LG 600A Frame 2-Pole with Thermal-Magnetic Trip Unit<br />

Model 525 Trip Unit<br />

N-Interrupting Class H-Interrupting Class L-Interrupting Class<br />

Continuous<br />

Ampere Rating<br />

Catalog Number Catalog Number<br />

COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER<br />

Catalog Number<br />

400 NLK2B400L HLK2B400L LLK2B400L<br />

500 NLK2B500L HLK2B500L LLK2B500L<br />

600 NLK2B600L HLK2B600L LLK2B600L<br />

LG 600A Frame 3-Pole with Thermal-Magnetic Trip Unit <br />

N-Interrupting Class H-Interrupting Class L-Interrupting Class<br />

Continuous<br />

Catalog Number Catalog Number Catalog Number<br />

Ampere Rating<br />

COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER<br />

400 NLK3B400L HLK3B400L LLK3B400L<br />

500 NLK3B500L HLK3B500L LLK3B500L<br />

600 NLK3B600L HLK3B600L LLK3B600L<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Type HLGC 600A Frame 2-Pole with Thermal-Magnetic Trip Unit , 600Vac 25kA only <br />

N-Interrupting Class H-Interrupting Class L-Interrupting Class<br />

Continuous<br />

Catalog Number Catalog Number Catalog Number<br />

Ampere Rating<br />

COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER<br />

400 — HLV2B400L —<br />

500 — HLV2B500L —<br />

600 — HLV2B600L —<br />

Type HLGC 600A Frame 3-Pole with Thermal-Magnetic Trip Unit , 600Vac 25kA only <br />

N-Interrupting Class H-Interrupting Class L-Interrupting Class<br />

Continuous<br />

Catalog Number Catalog Number Catalog Number<br />

Ampere Rating<br />

COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER<br />

400 — HLV3B400L —<br />

500 — HLV3B500L —<br />

600 — HLV3B600L —<br />

For 100% rated 400A or 500A versions, change the third<br />

character of the catalog number to “Z”.<br />

Consult sales office for availability.<br />

7-188<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


VL Circuit Breakers<br />

LG 600A Electronic Trip Units<br />

Selection<br />

LG 600A Frame 3-Pole Electronic Trip Unit<br />

Continuous<br />

Ampere Rating<br />

400<br />

600<br />

400<br />

600<br />

400<br />

600<br />

400<br />

600<br />

Model 555 Trip Unit<br />

N-Interrupting Class H-Interrupting Class L-Interrupting Class<br />

Catalog Number Catalog Number Catalog Number<br />

COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER<br />

ELECTRONIC LI TRIP<br />

NLK3R400L<br />

NLK3R600L<br />

NLK3T400L<br />

NLK3T600L<br />

NLK3V400L<br />

NLK3V600L<br />

NLK3W400L<br />

NLK3W600L<br />

HLK3R400L<br />

HLK3R600L<br />

ELECTRONIC LSI TRIP<br />

HLK3T400L<br />

HLK3T600L<br />

ELECTRONIC LSIG TRIP<br />

HLK3V400L<br />

HLK3V600L<br />

ELECTRONIC LIG TRIP<br />

HLK3W400L<br />

HLK3W600L<br />

LLK3R400L<br />

LLK3R600L<br />

LLK3T400L<br />

LLK3T600L<br />

LLK3V400L<br />

LLK3V600L<br />

LLK3W400L<br />

LLK3W600L<br />

7<br />

LG 600A Frame 3-Pole Electronic LCD Trip Unit<br />

Continuous<br />

Ampere Rating<br />

400<br />

600<br />

400<br />

600<br />

400<br />

600<br />

N-Interrupting Class H-Interrupting Class L-Interrupting Class<br />

Catalog Number Catalog Number Catalog Number<br />

COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER<br />

ELECTRONIC LSI TRIP<br />

NLK3A400L<br />

NLK3A600L<br />

NLK3G400L<br />

NLK3G600L<br />

NLK3K400L<br />

NLK3K600L<br />

HLK3A400L<br />

HLK3A600L<br />

ELECTRONIC LSIG TRIP<br />

HLK3G400L<br />

HLK3G600L<br />

ELECTRONIC LSI TRIP + GF ALARM ONLY<br />

HLK3K400L<br />

HLK3K600L<br />

Model 586 Trip Unit<br />

LLK3A400L<br />

LLK3A600L<br />

LLK3G400L<br />

LLK3G600L<br />

LLK3K400L<br />

LLK3K600L<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-189


VL Circuit Breakers<br />

Internal Accessories for JG 400A and LG 600A Frames<br />

Selection<br />

Auxiliary Switch and Alarm Switch Combination Kits<br />

Description Mounting Pocket a Catalog Number<br />

1 Alarm Switch<br />

1A/B c Left, Right b ASKL1<br />

Bases AMBL2 & AMBL3<br />

2 Aux. Switches<br />

1A + 1B Left, Right ASKL2<br />

Bases AMBL1<br />

2 Aux. + 1 Alarm Switches<br />

1A + 1B, 1A/B Left, Right b ASKL3<br />

Bases AMBL2 & AMBL3<br />

Auxiliary/Alarm Switch Mounting Base Only<br />

Description Mounting Pocket Catalog Number<br />

Up to 3 Auxiliary Switches Left, Right AMBL1<br />

2 Aux. + 1 Alarm Switch Left Pocket Only AMBL2<br />

2 Aux. + 1 Alarm Switch Right Pocket Only AMBL3<br />

Auxiliary/Alarm Switch Only<br />

Common to DG - PG Frames<br />

Description<br />

Catalog Number<br />

1 Normally Open Contact (1A) ASWPA<br />

1 Normally Closed Contact (1B) ASWPB<br />

Shunt Trips<br />

Description Mounting Pocket Catalog Number<br />

24 VDC STRLB24DC<br />

48-60 VDC STRLC60DC<br />

110-127 VDC STRLD125DC<br />

220-250 VDC Right Pocket Only STRLE250DC<br />

48-60 VAC STRLM60<br />

110-127 VAC STRLN120<br />

208-277 VAC STRLS277<br />

380-600 VAC STRLV600<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Undervoltage Release<br />

Description Mounting Pocket Catalog Number<br />

12 VDC UVRLA12DC<br />

24 VDC UVRLB24DC<br />

48 VDC UVRLC48DC<br />

60 VDC UVRLG60DC<br />

110-127 VDC UVRLD125DC<br />

220-250 VDC UVRLE250DC<br />

24 VAC Right Pocket Only UVRLL24<br />

110-127 VAC UVRLN120<br />

220-240 VAC UVRLR240<br />

208 VAC UVRLP208<br />

277 VAC UVRLS277<br />

380-415 VAC UVRLT415<br />

440-480 VAC UVRLU480<br />

UVRLN120<br />

a Refer to the “Accessory Locations” chart on page 7-218 for guidelines and limitations about which pockets<br />

may be used for accessory combinations.<br />

b Includes 1A and 1B contact for alarm purposes, only one of which may be installed at any time.<br />

‘A’ refers to a normally open contact (open when the breaker contacts are open).<br />

‘B’ refers to a normally closed contact (closed when the breaker contacts are open). External Accessories pages 7-205 through 7-217<br />

7-190<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


VL Circuit Breakers<br />

MG 800A Frame, VL Series<br />

Ordering Information<br />

Complete Assembled Breaker<br />

A complete factory assembled MG breaker includes the frame, trip unit, and<br />

standard line and load lugs, all factory installed and shipped as a complete<br />

breaker. Assembled breakers are available only with standard<br />

connectors.<br />

For any other configuration, order the frame, trip unit, and terminals as<br />

separate items.<br />

For DC applications, use thermal magnetic trip unit only.<br />

For reverse feed applications, select non-interchangeable trip breakers only. For<br />

non-interchangeable trip breakers, change the third digit of the catalog number<br />

to “X” for standard breakers.<br />

For 100% rated breakers with a non-interchangeable trip unit, change the 3 rd<br />

character of the catalog number to ”Y“.<br />

For special applications, refer to page 7-222.<br />

Mounting hardware is included with each frame or complete breaker.<br />

HACR rated.<br />

Interrupting Ratings<br />

Interrupting<br />

Class<br />

Breaker<br />

Type<br />

RMS Symmetrical Amperes (KA)<br />

UL 489 IEC 60947-2<br />

Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz)<br />

220/240 380/415 690<br />

240 480 600 250 500<br />

ICU ICS ICU ICS ICU ICS<br />

N NMG 65 35 25 22 35 65 65 50 50 20 10<br />

H HMG 100 65 35 25 50 100 75 70 70 30 15<br />

L LMG 200 100 50 42 65 200 150 100 75 35 17<br />

Selection/Dimensions<br />

Dimensions, inches (mm)<br />

Number<br />

To Handle<br />

of Poles Width Length Depth D1<br />

2, 3 7.5 (190) 16 (406) 4.7 (119) 5.9 (151)<br />

Shipping Weight, lbs. (kg)<br />

Complete<br />

Poles Frame Trip Unit Breaker<br />

2, 3 31.3 (14.2) 4.0 (1.8) 35.3 (16.0)<br />

Connectors for 75°C Wire<br />

Ampere Wire No. of cables<br />

Construction Rating Range per connector Catalog Number<br />

Aluminum 200-800A 1/0–500 kcmil Al/Cu 3 3TA3MG500 b<br />

Aluminum 200-800A 500-750 kcmil Al/Cu 2 3TA2MG750 b<br />

Copper 200-800A 1/0–500 kcmil Cu 3 TC3MG500 e<br />

Aluminum 200-800A #2–600 kcmil Al/Cu 3 3TA3MG600 bd<br />

a Standard connector supplied with complete breakers.<br />

b Kit consists of 3 terminal connectors.<br />

c Consists of one terminal.<br />

d Includes extended terminal cover.<br />

e Required for 100% rated MG breakers. Requires 90°C Cu cable sized at 75°C ampacity.<br />

MG Thermal-Magnetic,<br />

Instantaneous<br />

Trip Adjustment Range<br />

Instantaneous<br />

Trip Unit Continuous Overcurrent Setting (I i)<br />

Amp Rating (I n ) Min. Max.<br />

600 3000 6000<br />

700 3250 6500<br />

800 3250 6500<br />

Note: Each breaker has 6 trip settings.<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

External Accessories pages 7-205 through 7-217<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-191


VL Circuit Breakers<br />

MG 800A Thermal-Magnetic Trip Unit<br />

Selection<br />

Model 525 Trip Unit<br />

MG 800A Frame 2-Pole with Thermal-Magnetic Trip Unit<br />

N-Interrupting Class H-Interrupting Class L-Interrupting Class<br />

Catalog Number Catalog Number Catalog Number Catalog Number<br />

FRAME ONLY<br />

Continuous<br />

NMG2F800 HMG2F800 LMG2F800<br />

Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY<br />

600 NMG2B600L HMG2B600L LMG2B600L CMT2B600<br />

700 NMG2B700L HMG2B700L LMG2B700L CMT2B700<br />

800 NMG2B800L HMG2B800L LMG2B800L CMT2B800<br />

MG 800A Frame 3-Pole with Thermal-Magnetic Trip Unit<br />

N-Interrupting Class H-Interrupting Class L-Interrupting Class<br />

Catalog Number Catalog Number Catalog Number Catalog Number<br />

FRAME ONLY<br />

Continuous<br />

NMG3F800 HMG3F800 LMG3F800<br />

Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY<br />

600 NMG3B600L HMG3B600L LMG3B600L CMT3B600<br />

700 NMG3B700L HMG3B700L LMG3B700L CMT3B700<br />

800 NMG3B800L HMG3B800L LMG3B800L CMT3B800<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

7<br />

7-192<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


VL Circuit Breakers<br />

MG 800A Electronic Trip Units<br />

Selection<br />

Model 555 Trip Units<br />

MG 800A Frame 3-Pole Electronic Trip Unit<br />

N-Interrupting Class H-Interrupting Class L-Interrupting Class<br />

Catalog Number Catalog Number Catalog Number Catalog Number<br />

FRAME ONLY<br />

Continuous<br />

NMG3F800 HMG3F800 LMG3F800<br />

Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY<br />

ELECTRONIC LI TRIP<br />

600 NMG3R600L HMG3R600L LMG3R600L CMT3R600<br />

800 NMG3R800L HMG3R800L LMG3R800L CMT3R800<br />

ELECTRONIC LSI TRIP<br />

600 NMG3T600L HMG3T600L LMG3T600L CMT3T600<br />

800 NMG3T800L HMG3T800L LMG3T800L CMT3T800<br />

ELECTRONIC LSIG TRIP<br />

600 NMG3V600L HMG3V600L LMG3V600L CMT3V600<br />

800 NMG3V800L HMG3V800L LMG3V800L CMT3V800<br />

ELECTRONIC LIG TRIP<br />

600 NMG3W600L HMG3W600L LMG3W600L CMT3W600<br />

800 NMG3W800L HMG3W800L LMG3W800L CMT3W800<br />

MG 800A Frame 3-Pole Electronic LCD Trip Unit<br />

Model 586 Trip Unit<br />

N-Interrupting Class H-Interrupting Class L-Interrupting Class<br />

Catalog Number Catalog Number Catalog Number Catalog Number<br />

FRAME ONLY<br />

Continuous<br />

NMG3F800 HMG3F800 LMG3F800<br />

Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY<br />

LCD ELECTRONIC LSI TRIP<br />

600 NMG3A600L HMG3A600L LMG3A600L CMT3A600<br />

800 NMG3A800L HMG3A800L LMG3A800L CMT3A800<br />

LCD ELECTRONIC LSIG TRIP<br />

600 NMG3G600L HMG3G600L LMG3G600L CMT3G600<br />

800 NMG3G800L HMG3G800L LMG3G800L CMT3G800<br />

LCD ELECTRONIC LSI TRIP + GF ALARM ONLY<br />

600 NMG3K600L HMG3K600L LMG3K600L CMT3K600<br />

800 NMG3K800L HMG3K800L LMG3K800L CMT3K800<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-193


VL Circuit Breakers<br />

Internal Accessories for MG 800A, NG 1200A and PG 1600A Frames<br />

Selection<br />

Auxiliary Switch and Alarm Switch Combination Kits<br />

Description Mounting Pocket a Catalog Number<br />

2 Aux. + 2 Alarm Switches<br />

2A + 2B Left Pocket Only ASKP3<br />

Bases AMBP2<br />

4 Aux. Switches<br />

2A + 2B Left, Right ASKP4<br />

Bases AMBP1<br />

x4<br />

Auxiliary/Alarm Switch Mounting Base Only<br />

Description Mounting Pocket Catalog Number<br />

Up to 4 Auxiliary Switches Left, Right AMBP1<br />

2 Aux. + 2 Alarm Switches Left Pocket Only AMBP2<br />

Auxiliary/Alarm Switch Only<br />

Common to DG - PG Frames<br />

Description<br />

Catalog Number<br />

1 Normally Open Contact (1A) ASWPA<br />

1 Normally Closed Contact (1B) ASWPB<br />

x4<br />

Shunt Trips<br />

Description Mounting Pocket Catalog Number<br />

24 VDC STRPB24DC<br />

48-60 VDC STRPC60DC<br />

110-127 VDC STRPD125DC<br />

220-250 VDC Right Pocket Only STRPE250DC<br />

48-60 VAC STRPM60<br />

110-127 VAC STRPN120<br />

208-277 VAC STRPS277<br />

380-600 VAC STRPV600<br />

AMBP2<br />

Undervoltage Release<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Description Mounting Pocket Catalog Number<br />

12 VDC UVRPA12DC<br />

24 VDC UVRPB24DC<br />

48 VDC UVRPC48DC<br />

60 VDC UVRPG60DC<br />

110-127 VDC UVRPD125DC<br />

220-250 VDC UVRPE250DC<br />

110-127 VAC Right Pocket Only UVRPN120<br />

220-240 VAC UVRPR240<br />

208 VAC UVRPP208<br />

277 VAC UVRPS277<br />

380-415 VAC UVRPT415<br />

440-480 VAC UVRPU480<br />

a Refer to the “Accessory Locations” chart on page 7-218 for guidelines and limitations about which pockets<br />

may be used for accessory combinations.<br />

‘A’ refers to a normally open contact (open when the breaker contacts are open).<br />

‘B’ refers to a normally closed contact (closed when the breaker contacts are open).<br />

STRPN120<br />

UVRPN120<br />

External Accessories pages 7-205 through 7-217<br />

7-194<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


VL Circuit Breakers<br />

NG 1200A Frame, VL Series<br />

Ordering Information<br />

Complete Assembled Breaker with Lugs<br />

A complete factory assembled NG breaker includes the frame, trip unit,<br />

and standard line and load lugs, all factory installed and shipped as a complete<br />

breaker. Assembled breakers are available only with standard connectors.<br />

For any other configuration, order the frame, trip unit, and terminals as<br />

separate items.<br />

For DC applications, use thermal magnetic trip unit only.<br />

For reverse feed applications, select non-interchangeable trip breakers only. For<br />

non-interchangeable trip breakers, change the third digit of the catalog number<br />

to “X” for standard breakers.<br />

For 100% rated breakers with a non-interchangeable trip unit, change the 3 rd<br />

character of the catalog number to ”Y“.<br />

For special applications, refer to page 7-222.<br />

Mounting hardware is included with each frame or complete breaker.<br />

A Toggle Handle Extension is included with each frame or complete breaker.<br />

HACR rated.<br />

Interrupting Ratings<br />

Interrupting<br />

Class<br />

Breaker<br />

Type<br />

RMS Symmetrical Amperes (KA)<br />

UL 489 IEC 60947-2<br />

Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz)<br />

220/240 380/415 690<br />

240 480 600 250 500<br />

ICU ICS ICU ICS ICU ICS<br />

N NNG 65 35 25 22 35 65 35 50 25 20 10<br />

H HNG 100 65 35 25 50 100 50 70 35 30 15<br />

L LNG 200 100 65 42 65 200 100 100 50 35 17<br />

Selection/Dimensions<br />

Dimensions, inches (mm)<br />

Number<br />

To Handle<br />

of Poles W L D D1<br />

2, 3 9 (229) 16 (406) 6 (152) 8.1 (207)<br />

Shipping Weight, lbs. (kg)<br />

Complete<br />

Poles Frame Trip Unit Breaker<br />

2, 3 46.3 (21.0) 8.8 (4.0) 55.1 (25.0)<br />

Connectors for 75°C Wire<br />

Ampere Wire No. of cables<br />

Construction Rating Range per connector Catalog Number<br />

Aluminum 300-1200A 1/0–500 kcmil Al/Cu 4 3TA4NG500 cd<br />

Aluminum 300-1200A 500-750 kcmil Al/Cu 3 3TA3NG750 d<br />

Copper 300-1200A 1/0–500 kcmil Cu 4 3TC4NG500 bd<br />

Aluminum 300-1200A 1/0–500 kcmil Al/Cu 4 3TA4NG500H bd<br />

Compression Lugs<br />

300-1200A 1/0-500 kcmil Al/Cu — 12CLN500 <br />

a Total of 12 connectors (4 per phase Line or Load).<br />

b For 100% rated NG breakers. Requires 90°C Cu cable sized at 75°C ampacity.<br />

c Standard connector provided with complete breakers.<br />

d Kit consists of 3 terminal connectors.<br />

NG Thermal-Magnetic,<br />

Instantaneous<br />

Trip Adjustment Range<br />

Instantaneous<br />

Trip Unit Continuous Overcurrent Setting (I i)<br />

Amp Rating (I n ) Min. Max.<br />

800 4000 8000<br />

900 5000 10000<br />

1000 5000 10000<br />

1200 7000 12000<br />

Note: Each breaker has 6 trip settings.<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

External Accessories pages 7-205 through 7-217<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-195


VL Circuit Breakers<br />

NG 1200A Thermal-Magnetic Trip Unit<br />

Selection<br />

I i<br />

AMPS<br />

9000 10000<br />

8000<br />

11000<br />

I n=<br />

40 C<br />

TM ~<br />

1200A<br />

I i<br />

AMPS<br />

9000 10000<br />

8000<br />

11000<br />

I i<br />

AMPS<br />

9000 10000<br />

8000<br />

11000<br />

7000 12000<br />

Trip Unit/Disparador 525<br />

7000 12000<br />

Amps<br />

7000 12000<br />

Amps<br />

Model 525 Trip Unit<br />

NG 1200A Frame 2-Pole with Thermal-Magnetic Trip Unit<br />

N-Interrupting Class H-Interrupting Class L-Interrupting Class<br />

Catalog Number Catalog Number Catalog Number Catalog Number<br />

FRAME ONLY<br />

Continuous<br />

NNG2F120 HNG2F120 LNG2F120<br />

Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY<br />

800 NNG2B800L HNG2B800L LNG2B800L CNT2B800<br />

900 NNG2B900L HNG2B900L LNG2B900L CNT2B900<br />

1000 NNG2B100L HNG2B100L LNG2B100L CNT2B100<br />

1200 NNG2B120L HNG2B120L LNG2B120L CNT2B120<br />

NG 1200A Frame 3-Pole with Thermal-Magnetic Trip Unit<br />

N-Interrupting Class H-Interrupting Class L-Interrupting Class<br />

Catalog Number Catalog Number Catalog Number Catalog Number<br />

FRAME ONLY<br />

Continuous<br />

NNG3F120 HNG3F120 LNG3F120<br />

Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY<br />

800 NNG3B800L HNG3B800L LNG3B800L CNT3B800<br />

900 NNG3B900L HNG3B900L LNG3B900L CNT3B900<br />

1000 NNG3B100L HNG3B100L LNG3B100L CNT3B100<br />

1200 NNG3B120L HNG3B120L LNG3B120L CNT3B120<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

7<br />

7-196<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


VL Circuit Breakers<br />

NG 1200A Electronic Trip Units<br />

Selection<br />

Model 555 Trip Units<br />

NG 1200A Frame 3-Pole Electronic Trip Unit<br />

N-Interrupting Class H-Interrupting Class L-Interrupting Class<br />

Catalog Number Catalog Number Catalog Number Catalog Number<br />

FRAME ONLY<br />

Continuous<br />

NNG3F120 HNG3F120 LNG3F120<br />

Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY<br />

ELECTRONIC LI TRIP<br />

800 NNG3R800L HNG3R800L LNG3R800L CNT3R800<br />

1000 NNG3R100L HNG3R100L LNG3R100L CNT3R100<br />

1200 NNG3R120L HNG3R120L LNG3R120L CNT3R120<br />

ELECTRONIC LSI TRIP<br />

800 NNG3T800L HNG3T800L LNG3T800L CNT3T800<br />

1000 NNG3T100L HNG3T100L LNG3T100L CNT3T100<br />

1200 NNG3T120L HNG3T120L LNG3T120L CNT3T120<br />

ELECTRONIC LSIG TRIP<br />

800 NNG3V800L HNG3V800L LNG3V800L CNT3V800<br />

1000 NNG3V100L HNG3V100L LNG3V100L CNT3V100<br />

1200 NNG3V120L HNG3V120L LNG3V120L CNT3V120<br />

ELECTRONIC LIG TRIP<br />

800 NNG3W800L HNG3W800L LNG3W800L CNT3W800<br />

1000 NNG3W100L HNG3W100L LNG3W100L CNT3W100<br />

1200 NNG3W120L HNG3W120L LNG3W120L CNT3W120<br />

7<br />

NG 1200A Frame 3-Pole Electronic LCD Trip Unit<br />

Model 586 Trip Unit<br />

N-Interrupting Class H-Interrupting Class L-Interrupting Class<br />

Catalog Number Catalog Number Catalog Number Catalog Number<br />

FRAME ONLY<br />

Continuous<br />

NNG3F120 HNG3F120 LNG3F120<br />

Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY<br />

LCD ELECTRONIC LSI TRIP<br />

800 NNG3A800L HNG3A800L LNG3A800L CNT3A800<br />

1000 NNG3A100L HNG3A100L LNG3A100L CNT3A100<br />

1200 NNG3A120L HNG3A120L LNG3A120L CNT3A120<br />

LCD ELECTRONIC LSIG TRIP<br />

800 NNG3G800L HNG3G800L LNG3G800L CNT3G800<br />

1000 NNG3G100L HNG3G100L LNG3G100L CNT3G100<br />

1200 NNG3G120L HNG3G120L LNG3G120L CNT3G120<br />

LCD ELECTRONIC LSI TRIP + GF ALARM ONLY<br />

800 NNG3K800L HNG3K800L LNG3K800L CNT3K800<br />

1000 NNG3K100L HNG3K100L LNG3K100L CNT3K100<br />

1200 NNG3K120L HNG3K120L LNG3K120L CNT3K120<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-197


VL Circuit Breakers<br />

Internal Accessories for MG 800A, NG 1200A, and PG 1600A Frames<br />

Selection<br />

Auxiliary Switch and Alarm Switch Combination Kits<br />

Description Mounting Pocket a Catalog Number<br />

2 Aux. + 2 Alarm Switches<br />

2A + 2B Left Pocket Only ASKP3<br />

Base AMBP2<br />

4 Aux. Switches<br />

2A + 2B Left, Right ASKP4<br />

Base AMBP1<br />

x4<br />

Auxiliary/Alarm Switch Mounting Base Only<br />

Description Mounting Pocket a Catalog Number<br />

Up to 4 Auxiliary Switches Left, Right AMBP1<br />

2 Aux. + 2 Alarm Switches Left Pocket Only AMBP2<br />

Auxiliary/Alarm Switch Only<br />

Common to DG-PG Frames<br />

Description<br />

Catalog Number<br />

1 Normally Open Contact (1A) ASWPA<br />

1 Normally Closed Contact (1B) ASWPB<br />

x4<br />

Shunt Trips<br />

Description Mounting Pocket Catalog Number<br />

24 VDC STRPB24DC<br />

48-60 VDC STRPC60DC<br />

110-127 VDC STRPD125DC<br />

220-250 VDC Right Pocket Only STRPE250DC<br />

48-60 VAC STRPM60<br />

110-127 VAC STRPN120<br />

208-277 VAC STRPS277<br />

380-600 VAC STRPV600<br />

AMBP2<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Undervoltage Release<br />

Description Mounting Pocket Catalog Number<br />

12 VDC UVRPA12DC<br />

24 VDC UVRPB24DC<br />

48 VDC UVRPC48DC<br />

60 VDC UVRPG60DC<br />

110-127 VDC UVRPD125DC<br />

220-250 VDC UVRPE250DC<br />

110-127 VAC Right Pocket Only UVRPN120<br />

220-240 VAC UVRPR240<br />

208 VAC UVRPP208<br />

277 VAC UVRPS277<br />

380-415 VAC UVRPT415<br />

440-480 VAC UVRPU480<br />

a Refer to the “Accessory Locations” chart on page 7-218 for guidelines and limitations about which<br />

pockets may be used for accessory combinations.<br />

‘A’ refers to a normally open contact (open when the breaker contacts are open).<br />

‘B’ refers to a normally closed contact (closed when the breaker contacts are open).<br />

STRPN120<br />

UVRPN120<br />

External Accessories pages 7-205 through 7-217<br />

7-198<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


VL Circuit Breakers<br />

PG 1600A Frame, VL Series & Thermal-Magnetic Trip Unit<br />

Selection/Dimensions<br />

Ordering Information<br />

A complete factory assembled PG breaker includes the frame and trip unit only.<br />

The connectors must be ordered as separate items.<br />

PG thermal-magnetic breakers sold as non-interchangeable only.<br />

For any other configuration, order the frame, trip unit, and connectors as<br />

separate items.<br />

Connectors require a Breaker Lug Mounting Assembly or Breaker Mounting<br />

Base and must be ordered as a seperate item.<br />

For DC applications, use Thermal magnetic trip unit only.<br />

For reverse feed applications select non-interchangeable trip breakers only.<br />

Change the third digit of the catalog number to “X” for non-interchangeable trip<br />

breakers.<br />

For 100% rated breakers with a non-interchangeable trip unit, change the 3 rd<br />

character of the catalog number to ”Y“.<br />

For special applications, refer to page 7-222.<br />

Mounting hardware is included with each frame or complete breaker.<br />

A Toggle Handle Extension is included with each frame or complete breaker.<br />

Interrupting Ratings<br />

Interrupting<br />

Class<br />

Breaker<br />

Type<br />

Connectors for 75°C Wire<br />

Ampere Wire No. of cables<br />

Construction Rating Range per phase Catalog Number<br />

Aluminum 1200-1600A 1/0–750 kcmil Al/Cu 6 3TA6PG750 ac<br />

Aluminum 1200-1600A 300–600 kcmil Al/Cu 5 TA5P600 bd<br />

Aluminum 1200-1600A 600–750 kcmil Al/Cu 4 TA4P750 bd<br />

Aluminum 1200-1600A 300–600 kcmil Al/Cu 6 TA6R600 bd<br />

Copper 1200-1600A 300–600 kcmil Cu 5 TC5R600 bde<br />

Mounting Arrangement<br />

Description<br />

Lug Mounting Assembly<br />

Breaker Mounting Base (Front Connect)<br />

Breaker Mounting Base (Rear Connect)<br />

RMS Symmetrical Amperes (KA)<br />

UL 489<br />

IEC 60947-2 (ETU only)<br />

Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz)<br />

240 480 600 250 500<br />

Catalog Number<br />

LMAP1600<br />

MBPG1600<br />

MBPG1601<br />

220/240 380/415 690<br />

ICU ICS ICU ICS ICU ICS<br />

N NPG 65 35 25 22 35 65 35 50 25 20 10<br />

H HPG 100 65 35 25 50 100 50 70 35 30 15<br />

L LPG 200 100 65 42 65 200 100 100 50 35 17<br />

Dimensions, inches (mm)<br />

Number<br />

To Handle<br />

of Poles W L D D1<br />

2, 3 9 (229) 16 (406) 6 (152) 8.1 (207)<br />

Shipping Weight, lbs. (kg)<br />

Complete<br />

Poles Frame Trip Unit Breaker<br />

2, 3 60.2 (27.3) 8.8 (4.0) 69.0 (31.3)<br />

PG Thermal-Magnetic,<br />

Instantaneous<br />

Trip Adjustment Range<br />

Instantaneous<br />

Trip Unit Continuous Overcurrent Setting (I i)<br />

Amp Rating (I n ) Min. Max.<br />

1200 7000 12000<br />

1400 7000 12000<br />

1600 7000 12000<br />

Note: Each breaker has 6 trip settings in this range.<br />

I i<br />

AMPS<br />

9000 10000<br />

8000<br />

11000<br />

7000 12000<br />

I n = 1600A<br />

40º C<br />

TM ~<br />

Trip Unit/Disparador 525<br />

Model 525 Trip Unit<br />

I i<br />

AMPS<br />

9000 10000<br />

8000<br />

11000<br />

7000 12000<br />

Amps<br />

I i<br />

AMPS<br />

9000 10000<br />

8000<br />

11000<br />

7000 12000<br />

Amps<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

PG 1600A Frame 3-Pole with Thermal-Magnetic Trip Unit <br />

N-Interrupting Class H-Interrupting Class L-Interrupting Class<br />

Continuous Catalog Number Catalog Number Catalog Number<br />

Ampere Rating<br />

COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER<br />

1200 NPX3B120 HPX3B120 LPX3B120<br />

1400 NPX3B140 HPX3B140 LPX3B140<br />

1600 NPX3B160 HPX3B160 LPX3B160<br />

a Requires Lug Mounting Assembly LMAP1600.<br />

b Requires Breaker Mounting Base MBPG1600 Kit or<br />

MBPG1601.<br />

c Consists of 3 connectors.<br />

d Consists of 1 connector.<br />

e Required for 100% rated PG breakers. Requires 90°C cable<br />

sized at 75°C ampacity.<br />

IEC 60947-2: ONLY applies to Electronic Trip Units (ETUs).<br />

External Accessories pages 7-205 through 7-217<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-199


VL Circuit Breakers<br />

PG 1600A Electronic Trip Units<br />

Selection<br />

PG 1600A Frame 3-Pole Electronic Trip Unit<br />

Model 555 Trip Unit<br />

N-Interrupting Class H-Interrupting Class L-Interrupting Class<br />

Catalog Number Catalog Number Catalog Number Catalog Number<br />

FRAME ONLY<br />

Continuous<br />

NPG3F160 HPG3F160 LPG3F160<br />

Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY<br />

ELECTRONIC LI TRIP<br />

1200 NPG3R120 HPG3R120 LPG3R120 CPT3R120<br />

1600 NPG3R160 HPG3R160 LPG3R160 CPT3R160<br />

ELECTRONIC LSI TRIP<br />

1200 NPG3T120 HPG3T120 LPG3T120 CPT3T120<br />

1600 NPG3T160 HPG3T160 LPG3T160 CPT3T160<br />

ELECTRONIC LSIG TRIP<br />

1200 NPG3V120 HPG3V120 LPG3V120 CPT3V120<br />

1600 NPG3V160 HPG3V160 LPG3V160 CPT3V160<br />

ELECTRONIC LIG TRIP<br />

1200 NPG3W120 HPG3W120 LPG3W120 CPT3W120<br />

1600 NPG3W160 HPG3W160 LPG3W160 CPT3W160<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

PG 1600A Frame 3-Pole Electronic LCD Trip Unit<br />

Model 586 Trip Unit<br />

N-Interrupting Class H-Interrupting Class L-Interrupting Class<br />

Catalog Number Catalog Number Catalog Number Catalog Number<br />

FRAME ONLY<br />

Continuous<br />

NPG3F160 HPG3F160 LPG3F160<br />

Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY<br />

LCD ELECTRONIC LSI TRIP<br />

1200 NPG3A120 HPG3A120 LPG3A120 CPT3A120<br />

1600 NPG3A160 HPG3A160 LPG3A160 CPT3A160<br />

LCD ELECTRONIC LSIG TRIP<br />

1200 NPG3G120 HPG3G120 LPG3G120 CPT3G120<br />

1600 NPG3G160 HPG3G160 LPG3G160 CPT3G160<br />

LCD ELECTRONIC LSI TRIP + GF ALARM ONLY<br />

1200 NPG3K120 HPG3K120 LPG3K120 CPT3K120<br />

1600 NPG3K160 HPG3K160 LPG3K160 CPT3K160<br />

7-200<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


VL Circuit Breakers<br />

Internal Accessories for MG 800A, NG 1200A, and PG 1600A Frames<br />

Selection<br />

Auxiliary Switch and Alarm Switch Combination Kits<br />

Description Mounting Pocket a Catalog Number<br />

2 Aux. + 2 Alarm Switches<br />

2A + 2B Left Pocket Only ASKP3<br />

Base AMBP2<br />

4 Aux. Switches<br />

2A + 2B Left, Right ASKP4<br />

Base AMBP1<br />

x4<br />

Auxiliary/Alarm Switch Mounting Base Only<br />

Description Mounting Pocket a Catalog Number<br />

Up to 4 Auxiliary Switches Left, Right AMBP1<br />

2 Aux. + 2 Alarm Switches Left Pocket Only AMBP2<br />

Auxiliary/Alarm Switch Only<br />

Common to DG-PG Frames<br />

Description<br />

Catalog Number<br />

1 Normally Open Contact (1A) ASWPA<br />

1 Normally Closed Contact (1B) ASWPB<br />

x4<br />

Shunt Trips<br />

Description Mounting Pocket Catalog Number<br />

24 VDC STRPB24DC<br />

48-60 VDC STRPC60DC<br />

110-127 VDC STRPD125DC<br />

220-250 VDC Right Pocket Only STRPE250DC<br />

48-60 VAC STRPM60<br />

110-127 VAC STRPN120<br />

208-277 VAC STRPS277<br />

380-600 VAC STRPV600<br />

AMBP2<br />

Undervoltage Release<br />

Description Mounting Pocket Catalog Number<br />

12 VDC UVRPA12DC<br />

24 VDC UVRPB24DC<br />

48 VDC UVRPC48DC<br />

60 VDC UVRPG60DC<br />

110-127 VDC UVRPD125DC<br />

220-250 VDC UVRPE250DC<br />

110-127 VAC Right Pocket Only UVRPN120<br />

220-240 VAC UVRPR240<br />

208 VAC UVRPP208<br />

277 VAC UVRPS277<br />

380-415 VAC UVRPT415<br />

440-480 VAC UVRPU480<br />

STRPN120<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

a Refer to the “Accessory Locations” chart on page 7-218 for guidelines and limitations about which<br />

pockets may be used for accessory combinations.<br />

‘A’ refers to a normally open contact (open when the breaker contacts are open).<br />

‘B’ refers to a normally closed contact (closed when the breaker contacts are open).<br />

UVRPN120<br />

External Accessories pages 7-205 through 7-217<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-201


VL Circuit Breakers<br />

Molded Case Switch<br />

General<br />

Typically a molded case switch is used<br />

when a compact load-break switch is<br />

needed for disconnect purposes. The<br />

VL line of molded case switches from<br />

Siemens is made of the same materials<br />

and components as the VL circuit<br />

breakers but do not provide overcurrent<br />

protection. Each molded case<br />

switch has a fixed instantaneous selfprotecting<br />

trip element which may<br />

open the switch under high fault conditions.<br />

Application Note<br />

Overcurrent protection must be provided<br />

by an appropriate overcurrent protective<br />

device located upstream from<br />

Selection<br />

the molded case switch. Also, the<br />

short-circuit current rating of the<br />

switch is limited to the interrupting rating<br />

of the upstream protective device<br />

or the ratings in the table below,<br />

whichever is less.<br />

Ordering Information<br />

Each type VL molded case switch accepts the same terminals and accessories as the equivalent VL circuit breakers.<br />

All type VL molded case switches are suitable for reverse feed applications.<br />

Mounting hardware and standard line and load terminals are included on ratings through 250A. For 400 – 1600A ratings,<br />

order the lugs separately.<br />

All ratings are UL listed and CSA certified.<br />

Molded Case Switch<br />

Maximum<br />

Ampere<br />

Rating / Frame<br />

2-Pole 3-Pole Short-Circuit Current Rating Self Protective<br />

Instantaneous<br />

Catalog Number Catalog Number 240V 480V 600V Override<br />

150A / DG HDR2S150 HDR3S150 100k 65k 20k 2,500A<br />

250A / FG HFR2S250 HFR3S250 100k 65k 20k 3,500A<br />

400A / JG HJS2S400 HJS3S400 100k 65k 25k 4,400A<br />

600A / LG HLR2S600 HLR3S600 100k 65k 18k 5,500A<br />

800A / MG HMS2S800 HMS3S800 100k 65k 35k 6,500A<br />

1200A / NG HNS2S120 HNS3S120 100k 65k 35k 12,000A<br />

1600A / PG — HPS3S160 100k 65k 35k 14,000A<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Maximum<br />

Ampere<br />

Rating / Frame<br />

3-Pole Short-Circuit Current Rating Self Protective<br />

Instantaneous<br />

Catalog Number 240V 480V 600V Override<br />

250A / FG LFR3S250 200k 100k 25k 3,500A<br />

400A / JG LJS3S400 200k 100k 25k 4,400A<br />

600A / LG LLR3S600 200k 100k 18k 5,500A<br />

800A / MG LMS3S800 200k 100k 65k 6,500A<br />

1200A / NG LNS3S120 200k 100k 65k 12,000A<br />

1600A / PG LPS3S160 200k 100k 65k 14,000A<br />

The Short-Circuit Current Rating is the maximum available<br />

current of the circuit where the switch is used, when protected<br />

by an appropriate overcurrent protective device.<br />

7-202<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


VL Circuit Breakers<br />

Motor Circuit Protectors<br />

Selection<br />

General<br />

Protection of Motor Circuits<br />

Molded case circuit breakers are used in motor circuits as a disconnecting means and for short-circuit protection. They should be<br />

used in conjunction with motor-running, over-current protection devices, and should permit the motor to start without nuisance tripping<br />

from motor-inrush current. The circuit breaker should have a continuous current rating of not less than 115% of the motor fullload<br />

current.<br />

The recommended motor circuit protectors listed have continuous-current ratings of at least 115% of motor full-load currents. The<br />

trip setting positions are approximately 11 times motor full-load current. The suggested trip settings may need to be adjusted<br />

upward to no higher than 1300% of full-load current for non-design E type motors, and no greater than 1700% of full-load current<br />

for design E motors, to allow for motor startup due to in-rush current.<br />

Breaker Mounted Immediately Ahead of Motor Starter<br />

Siemens motor circuit protectors are recommended for use in combination motor starters to provide selective short-circuit protection<br />

for the motor branch circuit. The adjustable instantaneous trip feature of the Siemens motor circuit protector provides for a trip<br />

setting slightly above the peak motor in-rush current. With this setting, no delay is introduced in opening the circuit when a fault<br />

occurs. This circuit breaker has no time-delay trip element. Therefore it must be used in conjunction with, and immediately ahead<br />

of, the motor-running overcurrent protection device.<br />

Important: The information below does not apply to all motor applications: it is recommended that the user refer to the National<br />

Electrical Code (NEC) for specific needs.<br />

Table 1 (When Breaker is Mounted Immediately Ahead of Motor Starter)<br />

3-Phase Induction Type Motors (Siemens motor circuit protectors for branch circuit use with alternating-current combination, full voltage motor starters)<br />

Motor Full<br />

Trip<br />

Load Amperes Setting (A) Catalog Number a<br />

35-50 450<br />

42-60 540<br />

48-70 630 HDP3L150L<br />

55-80 720<br />

62-90 810<br />

69-100 900<br />

58-83 750<br />

69-100 900<br />

81-117 1050 HDP3M150L<br />

92-133 1200<br />

104-150 1350<br />

115-150 b 1500<br />

96-139 1250<br />

115-150 b 1500<br />

135-150 b 1750 HDP3H150L<br />

135-150 b 2000<br />

135-150 b 2250<br />

135-150 b 2500<br />

46-67 600<br />

55-80 720<br />

65-93 840 HFP3L250L<br />

74-107 960<br />

83-120 1080<br />

92-133 1200<br />

77-111 1000<br />

92-133 1200<br />

108-156 1400 HFP3M250L<br />

123-178 1600<br />

138-200 1800<br />

154-222 2000<br />

135-194 1750<br />

162-210 2100<br />

188-220 2450 HFP3H250L<br />

215-241 2800<br />

242-250 b 3150<br />

242-250 b 3500<br />

Motor Full<br />

Trip<br />

Load Amperes Setting (A) Catalog Number a<br />

96-139 1250<br />

115-167 1500<br />

135-194 1750 HJM3L400<br />

154-222 2000<br />

173-250 2250<br />

192-278 2500<br />

154-222 2000<br />

185-267 2400<br />

215-311 2800 HJM3M400<br />

246-356 3200<br />

277-400 3600<br />

308-400 b 4000<br />

154-222 2000<br />

185-267 2400<br />

215-311 2800 HLM3J600<br />

246-356 3200<br />

277-400 3600<br />

308-444 4000<br />

212-306 2750<br />

254-367 3300<br />

296-428 3850 HLM3Y600<br />

338-489 4400<br />

381-550 4950<br />

423-600 5500<br />

250-361 3250<br />

292-422 3800<br />

335-483 4350 HMM3M800<br />

385-556 5000<br />

442-638 5740<br />

500-722 6500<br />

385-556 5000<br />

462-667 6000<br />

538-778 7000 HNM3M120<br />

615-889 8000<br />

692-1000 9000<br />

769-1111 10,000<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

a Motor circuit protectors rated 150A and 250A are supplied with line and load lugs<br />

installed. If lugs are required on 400A to 1200A motor circuit breakers, order required<br />

lugs separately.<br />

b These settings are provided for starting currents greater than 11X but not to exceed<br />

17X. Full Load Amps ( FLA ) not to exceed ampere rating of MCP.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-203


VL Circuit Breakers<br />

Revised on 10/31/18<br />

600 Volt DC Circuit Breakers Selection<br />

General<br />

Siemens UL Listed non-interchangeable<br />

trip DC Thermal/magnetic Molded Case<br />

Circuit Breakers shown below are for use<br />

in grounded & ungrounded general DC<br />

circuits and ungrounded battery supply<br />

circuits of UPS systems. These breakers<br />

are rated at 600Vdc closed circuit and<br />

feature rated interruption levels from<br />

42,000 to 65,000 amperes as indicated in<br />

the table. This family of circuit breakers<br />

is rated from 100 to 1600 Amperes.<br />

Types HFGD through HPGD circuit breakers<br />

are provided with an adjustable<br />

magnetic over-current function located<br />

on the face of the circuit breaker.<br />

Contact Siemens for specific magnetic<br />

over-current values.<br />

To properly use these UL Listed circuit<br />

breakers at 600Vdc and the indicated<br />

interruption level, it is necessary to<br />

connect the terminals of the 3 pole<br />

circuit breaker in a series configuration<br />

as shown in the diagram below.<br />

Types HFGD through HPGD use the<br />

same internal and external accessories<br />

as the standard FG through PG frames<br />

and associated types. Consult the<br />

individual frame section for accessory<br />

information.<br />

Frame<br />

Type<br />

Continuous<br />

Ampere Rating<br />

Catalog<br />

Number<br />

(3-pole) a<br />

Short-Circuit<br />

Current Rating<br />

600VDC b<br />

+ –<br />

100 HFC3B100 42K<br />

150 HFC3B150 42K<br />

FG<br />

HFGD<br />

175 HFC3B175 42K<br />

200 HFC3B200 42K<br />

250 HFC3B250 42K<br />

250 HJC3B250 65K<br />

JG<br />

HJGD<br />

300 HJC3B300 65K<br />

350 HJC3B350 65K<br />

LOAD<br />

400 HJC3B400 65K<br />

400 HLC3B400 65K<br />

LG<br />

HLGD<br />

500 HLC3B500 65K<br />

600 HLC3B600 65K<br />

600 HMC3B600 65K<br />

MG<br />

HMGD<br />

700 HMC3B700 65K<br />

800 HMC3B800 65K<br />

800 HNC3B800 65K<br />

7<br />

NG<br />

HNGD<br />

900 HNC3B900 65K<br />

1000 HNC3B100 65K<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

PG<br />

HPGD<br />

1200 HNC3B120 65K<br />

1200 HPC3B120 65K<br />

1400 HPC3B140 65K<br />

1600 HPC3B160 65K<br />

a Terminal connectors must be ordered separately; see page 7-212.<br />

b Standard VL breakers DG - PG feature DC ratings up to 500V for ungrounded UPS<br />

applications. Consult the individual frame section for more information.<br />

7-204<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


External Accessories<br />

Selection<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

1 Base for Plug-In or Draw-Out<br />

2 Interphase Barriers<br />

3 Rear Terminals – Flat and Round<br />

4 Bus Extensions<br />

5 Terminal Connectors<br />

6 Plug-In Terminal Blades<br />

7 Extended Terminal Shield<br />

8 Standard Terminal Shield<br />

9 Cover Frame for Door Cutout<br />

10 Stored Energy Operator<br />

11 Rotary Handle Operator<br />

12 Variable Depth Rotary Operator<br />

13 Max Flex Operator<br />

14 Circuit Breaker<br />

15 Shunt Trip or Undervoltage Releases<br />

16 Auxiliary/Alarm Switches<br />

17 Thermal Magnetic Trip Unit (525)<br />

18 Electronic Trip Unit (555)<br />

19 Elec. Trip Unit with LCD (586)<br />

20 Communication Module with ZSI<br />

21 Electronic Trip Unit Tester and<br />

LCD Power Supply<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-205


External Accessories<br />

Operating Mechanisms<br />

RHFF<br />

RHVF12<br />

For DG to FG Frame For JG to LG Frame<br />

150 to 250 A 400 A to 600 A<br />

Description Catalog Number Catalog Number<br />

Through-Door Rotary Handle Operator Kit<br />

Fixed depth and the handle is mounted<br />

directly on the circuit breaker.<br />

Lockable knob (for up to 3 padlocks).<br />

NEMA 1, 12 RHFF RHFL<br />

Red Handle Version<br />

with red knob, yellow indicator plate<br />

NEMA 1, 12 RHFFEM RHFLEM<br />

Door-Mounted Rotary Handle Operator Kit<br />

Variable depth, door mounted handle.<br />

Includes knob with masking frame,<br />

indicator plate, detachable door coupling,<br />

12” shaft, and breaker mounted rotary<br />

operator. Lockable knob (for up to 3<br />

padlocks).<br />

NEMA 1, 12 RHVF12 RHVL12<br />

RHVFBM<br />

Auxiliary Switch Kits<br />

For Direct or Extended Rotary<br />

Handle Operators (RHF and RHV).<br />

Form C, Early Break type2 Aux. Switch Kit a<br />

Includes 1 switch with 5’ wire<br />

For Door-Mounted Operator — — RHSLA1<br />

For Through-Door Operator RHSFA1F RHSLA1F<br />

Includes 2 switches with 5’ wire<br />

For Door-Mounted Operator — — RHSLA2<br />

For Through-Door Operator RHSFA2F RHSLA2F<br />

Door-Mounted Rotary Operator Mechanism<br />

Breaker mechanism only RHVFBM RHVLBM<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

RHVM3RH<br />

RHVMS12<br />

Door-Mounted Rotary Handle Only<br />

Standard version NEMA 1, 12 RHVM12H RHVM12H<br />

NEMA 3R RHVM3RH RHVM3RH<br />

NEMA 4X RHVM4XH RHVM4XH<br />

Red Handle version RHVMEMH RHVMEMH<br />

NFPA-79 Handle Kit<br />

Intermediate handle for NFPA-79 compliance<br />

with door-mounted rotary operator RHVF79H RHVM79H<br />

Extension Shaft Only, for Door Mounted Operator<br />

2 inches (50.8mm) RHVMS02 RHVMS02<br />

3 inches (76.2mm) — — — —<br />

12 inches (304.8 mm) RHVMS12 RHVMS12<br />

16 inches (406.4 mm) RHVMS16 RHVMS16<br />

24 inches (609.6mm) w/ support bracket RHVMS24 RHVMS24<br />

RHVM12H<br />

a During manual operation, Early Break auxiliary switch contacts open before the breaker opens.<br />

7-206<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


For MG Frame<br />

For NG to PG Frame<br />

800 A 1200 to 1600 A<br />

Description Catalog Number Catalog Number<br />

Through-Door Rotary Handle Operator Kit<br />

Fixed depth, breaker mounted.<br />

For direct fitting to the circuit breaker.<br />

Lockable with up to 3 padlocks.<br />

NEMA 1, 12 — — — —<br />

Red Handle version<br />

with red knob, yellow indicator plate<br />

NEMA 1, 12 — — — —<br />

Door-Mounted Rotary Handle Operator Kit<br />

Variable depth, door mounted handle.<br />

Includes knob with masking frame,<br />

indicator plate, detachable door coupling,<br />

12” shaft, and breaker mounted rotary<br />

operator. Lockable knob (for up to 3<br />

padlocks).<br />

NEMA 1, 12 RHVM12 — —<br />

Auxiliary Switch Kits<br />

For Direct or Extended Rotary<br />

Handle Operators (RHF and RHV).<br />

Early Break type2 Aux. Switch Kit<br />

Includes 1 switch with 5’ wire<br />

For Door-Mounted Operator RHSMA1 RHSPA1<br />

For Through-Door Operator — — — —<br />

Includes 2 switches with 5’ wire<br />

For Door-Mounted Operator RHSMA2 RHSPA2<br />

For Through-Door Operator — — — —<br />

Door-Mounted Rotary Operator Mechanism<br />

Breaker mechanism only RHVMBM RHVPBM<br />

Door-Mounted Rotary Handle Only<br />

Standard version NEMA 1, 12 RHVM12H RHVP3RH<br />

NEMA 3R RHVM3RH RHVP3RH<br />

NEMA 4X RHVM4XH RHVP4XH<br />

Red Handle version RHVMEMH RHVPEMH<br />

NFPA-79 Handle Kit<br />

Intermediate handle for NFPA-79 compliance<br />

with door-mounted rotary operator RHVM79H RHVP79H<br />

Extension Shaft Only, for Door Mounted Operator<br />

2 inches (50.8mm) RHVMS02 — —<br />

3 inches (76.2mm) — — RHVPS03<br />

12 inches (304.8 mm) RHVMS12 RHVPS12<br />

16 inches (406.4 mm) RHVMS16 — —<br />

24 inches (609.6mm) w/ support bracket RHVMS24 RHVPS24<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-207


External Accessories<br />

Operating Mechanisms<br />

For DG and FG Frame For JG and LG Frame<br />

150 to 250 A 400 to 600 A<br />

Description Catalog Number Catalog Number<br />

Variable Depth Flange Mounted Operator Kit<br />

Adjustable from 8” to 16”<br />

Complete kit, includes handle and<br />

variable depth operator.<br />

NEMA 1, 3R, 12 FHVF3R FHVL3R<br />

NEMA 4X FHVF4X FHVL4X<br />

IEC Black Handle NEMA 1, 3R, 12 FHVF3RB FHVL3RB<br />

NEMA 4X FHVF4XB FHVL4XB<br />

Max-Flex, Variable Depth Flange<br />

Mounted Operator Kit<br />

Complete kit, includes plastic handle, breaker<br />

operator, and cable. NEMA 1, 3R, 12 MFKF3R MFKL3R<br />

For DG and FG operators, the cable is 36”,<br />

all others are 48”<br />

May be right- or left-hand mounted<br />

Handle Only, for Max-Flex Variable Depth<br />

NEMA 1, 3R, 12 Plastic MFHM3R MFHM3R<br />

NEMA 1, 3R, 12 Steel - epoxy coated MFHM3RS MFHM3RS<br />

NEMA 4, 4X Steel - chrome plated MFHM4X MFHM4X<br />

Solid color (all gray) Plastic a<br />

NEMA 1, 3R, 12 MFHM3RB MFHM3RB<br />

Solid color (black handle) Steel epoxy coated a<br />

NEMA 1, 3R, 12 MFHM3RSB MFHM3RSB<br />

Breaker Operator Mechanism Only, for Max-Flex MFMF MFML<br />

Cable Only, for Max-Flex Variable Depth<br />

36” MFCF036 MFCM036<br />

48” MFCF048 MFCM048<br />

60” MFCF060 MFCM060<br />

72” MFCF072 MFCM072<br />

84” MFCF084 MFCM084<br />

96” MFCF096 MFCM096<br />

120” MFCF120 MFCM120<br />

144” MFCF144 MFCM144<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Handle Auxiliary Switch<br />

Form C (1NO - 1NC), early break b<br />

1 Aux. switch MFSFA1 MFSLA1<br />

2 Aux. switch MFSFA2 MFSLA2<br />

a Max-Flex handles are available with solid gray or black handles instead of the customary “Red for On” flange handle.<br />

The black handle is preferred for IEC markets, where red handles have a specific meaning.<br />

b During manual operation, Early Break aux. contacts open before the breaker opens.<br />

7-208<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


For MG Frame For NG Frame For PG Frame<br />

800 A 1200 A 1600 A<br />

Description Catalog Number Catalog Number Catalog Number<br />

Variable Depth Flange Mounted Operator Kit<br />

Adjustable from 8” to 16”<br />

Complete kit, includes handle and<br />

variable depth operator.<br />

NEMA 1, 3R, 12 — —<br />

NEMA 4X — —<br />

IEC Black Handle NEMA 1, 3R, 12 — —<br />

NEMA 4X — —<br />

Max-Flex, Variable Depth Flange<br />

Mounted Operator Kit<br />

Complete kit, includes plastic handle, breaker<br />

operator, and cable. NEMA 1, 3R, 12 MFKM3R MFKP3RS MFKP3RS<br />

For DG and FG operators, the cable is 36”,<br />

all others are 48”<br />

May be right- or left-hand mounted<br />

Handle Only, for Max-Flex Variable Depth<br />

NEMA 1, 3R, 12 Plastic MFHM3R — —<br />

NEMA 1, 3R, 12 Steel - epoxy coated MFHM3RS MFHP3RS MFHP3RS<br />

NEMA 4, 4X Steel - chrome plated MFHM4X MFHP4X MFHP4X<br />

Solid color (all gray) Plastic a<br />

NEMA 1, 3R, 12 MFHM3RB — —<br />

Solid color (black handle) Steel epoxy coated a<br />

NEMA 1, 3R, 12 MFHM3RSB MFHP3RSB MFHP3RSB<br />

Breaker Operator Mechanism Only, for Max-Flex MFMM MFMP MFMP<br />

Cable Only, for Max-Flex Variable Depth<br />

36” MFCM036 — —<br />

48” MFCM048 MFCP048 MFCP048<br />

60” MFCM060 MFCP060 MFCP060<br />

72” MFCM072 MFCP072 MFCP072<br />

84” MFCM084 — —<br />

96” MFCM096 MFCP096 MFCP096<br />

120” MFCM120 MFCP120 MFCP120<br />

144” MFCM144 MFCP144 MFCP144<br />

Handle Auxiliary Switch<br />

Form C (1NO - 1NC), early break b<br />

1 Aux. switch MFSPA1 MFSPA1 MFSPA1<br />

2 Aux. switch MFSPA2 MFSPA2 MFSPA2<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

a Max-Flex handles are available with solid gray or black handles instead of the customary “Red for On” flange handle.<br />

The black handle is preferred for IEC markets, where red handles have a specific meaning.<br />

b During manual operation, Early Break aux. contacts open before the breaker opens.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-209


External Accessories<br />

Revised on 11/30/19<br />

Operating Mechanisms<br />

Description<br />

Stored Energy and Motor Operators<br />

Lockable with up to 3 padlocks.<br />

For DG to FG Frame<br />

150 to 250 A<br />

Catalog Number<br />

AC Voltage DC Voltage<br />

Stored Energy Type<br />

— 24 SEAFB<br />

42-48 42-48 SEAFM<br />

60 60 SEAFY<br />

110–127 110–127 SEAFN<br />

220–250 220–250 SEAFR<br />

Cylinder Locks for Field Installation<br />

CLKF<br />

Connections<br />

For DG Frame<br />

For FG Frame<br />

150 A 250 A<br />

Description Catalog Number Catalog Number<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Standard 3-Pole Set<br />

Terminal Shields<br />

Front Bus Bar Connections<br />

Includes nut keeper plates and shield.<br />

Standard (straight)<br />

3-Pole Set FBCD3 FBCF3<br />

Bus Bar Connection Strap Kit — —<br />

Includes 6 - Bus Bars, 6 Nut Keepers & Shields — —<br />

100% rated applications<br />

Terminal Shields<br />

Includes 2 terminal shields.<br />

3-Pole Standard Shield TSSF3 TSSF3<br />

3-Pole Extended Shield TSLF3 TSLF3<br />

Interphase Barriers<br />

Set of 2 barriers IPBF IPBF<br />

Also fits plug-in and draw-out bases.<br />

Lug Mounting Assy. — —<br />

Breaker Mounting Base<br />

Front connected — —<br />

Rear connected — —<br />

IPBF<br />

7-210<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Revised on 11/30/19<br />

For JG to LG Frame For MG Frame For NG to PG Frame<br />

400 to 600 A 800 A 1200 to 1600 A<br />

Catalog Number Catalog Number Catalog Number<br />

Stored Energy Type Stored Energy Type Motor Operator Type<br />

SEALB SEAMB MTRPB<br />

SEALM SEAMM MTRPM<br />

SEALY SEAMY MTRPY<br />

SEALN SEAMN MTRPN<br />

SEALR SEAMR MTRPR<br />

CLKP CLKP CLKP<br />

For JG Frame For LG Frame For MG Frame For NG Frame For PG Frame<br />

400 A 600 A 800 A 1200 A 1600 A<br />

Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number<br />

FBCJ3 FBCL3 FBCM3<br />

— — — SSBP SSBP<br />

SSBPH<br />

SSBPH<br />

7<br />

TSSL3 — TSSM3 TSSP3 TSSP3<br />

TSLL3 — TSLM3 TSLP3 TSLP3<br />

IPBM IPBM IPBM IPBP IPBP<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

— — — — LMAP1600 b<br />

— — — — MBPG1600<br />

— — — — MBPG1601<br />

a Not for use with standard Al terminals. Use Standard<br />

Shield for rear connection and Extended Shield for busbar<br />

connection.<br />

b Kit includes connection for one side of breaker only.<br />

Order quantity 2 if connecting line and load side.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-211


External Accessories<br />

Connections<br />

For DG Frame<br />

For FG Frame<br />

150 A 250 A<br />

Description Catalog Number Catalog Number<br />

Nut Keeper Plates<br />

For ring/tongue terminal or bus bar connections.<br />

(For metric threads on other than the JG frame,<br />

change ”TNK” to ”TMK”)<br />

1 Nut Keeper Plate TNKD TNKF<br />

Kit of 3 TNKD3 TNKF3<br />

TNKD3<br />

Mechanical Lugs<br />

Steel Wrap Around Body (Cu Wire Only)<br />

Cable Size; (cables per phase) #8-1/0; 1-hole #4-350 kcmil; 1-hole<br />

Single Lug TW1DG20 TW1FG350<br />

Kit of 3 3TW1DG20 3TW1FG350<br />

Aluminum Body (Al or Cu Wire)<br />

Cable Size; (cables per phase) #6-3/0; 1-hole #4-350 kcmil; 1-hole<br />

Single Lug TA1DG30 TAW1FG350<br />

Kit of 2 — —<br />

Kit of 3 3TA1DG30 3TAW1FG350<br />

Cable Size; (cables per phase) — —<br />

Single Lug — —<br />

Kit of 2 — —<br />

Kit of 3 — —<br />

3TA2LG600LD<br />

Cable Size; (cables per phase) — —<br />

Single Lug — —<br />

<br />

— —<br />

Copper Body (Cu Wire Only)<br />

Cable Size; (cables per phase) #6-3/0; 1-hole #4-350 kcmil; 1-hole<br />

Single Lug TC1DG30 TCW1FG350 <br />

Kit of 2 — —<br />

Kit of 3 3TC1DG30 3TCW1FG350 <br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

3TA4NG500<br />

Cable Size; (cables per phase) — —<br />

Single Lug — —<br />

Compression Lugs<br />

Cable Size; (cables per phase) #14-2/0; 1-cable #4-350 kcmil; 1-cable<br />

Kit of 2 2CLD20 —<br />

Kit of 3 3CLD20 3CLF350<br />

Cable Size; (cables per phase) —<br />

Kit of 2 —<br />

Kit of 3 — —<br />

Cable Size; (cables per phase) — —<br />

Kit of 3 — —<br />

Distribution Lugs (Cu Wire Only)<br />

#14-#1; 2-hole and<br />

Cable Size; (cables per phase) #14-#2; 3-hole #14-2/0; 1-hole<br />

Single Lug TA3DG02 TA3FG20<br />

Kit of 3 3TA3DG02 3TA3FG20<br />

Cable Size; (cables per phase) #14-#4; 6-hole #14-#4; 6-hole<br />

Single Lug TA6DG04 TA6FG04<br />

Kit of 3 3TA6DG04 3TA6FG04<br />

Note: pictures provide graphical<br />

representaions only.<br />

Control Wire Terminals<br />

Control Wire Terminal (Single) — —<br />

Control Wire Terminal (Kit of 3) — —<br />

Required for 100% rated breakers. Requires 90°C cable<br />

sized at 75°C ampacity.<br />

7-212<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


For JG Frame For LG Frame For MG Frame For NG Frame For PG Frame<br />

400 A 600 A 800 A 1200 A 1600 A<br />

Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number<br />

TMKJ TNKL TNKM TNKP TNKP<br />

TMKJ3 TNKL3 TNKM3 TNKP3 TNKP3<br />

metric only<br />

1/0-600 kcmil; 1-hole — — — —<br />

TW1JG600 — — — —<br />

3TW1JG600 — — — —<br />

3/0-250 kcmil; 2-hole #2-600 kcmil; 2-hole 1/0-500 kcmil, 3-hole 1/0-500 kcmil; 4-hole 1/0-750 kcmil; 6-hole<br />

TA2JG250 — TA3MG500 — —<br />

— — 3TA3MG500 2TA4NG500 —<br />

—<br />

3TA2JG250 3TA2LG600LD a 3TA4NG500 3TA6PG750 e<br />

3TA2LG600LN b<br />

3TA4NG500H c<br />

AL: 250-750 kcmil<br />

AL: 250-750 kcmil<br />

CU: 3/0-600 kcmil; 1-hole CU: 3/0-600 kcmil; 1-hole 500 -750 kcmil; 2-hole 500 -750 kcmil; 3-hole 600-750 kcmil; 4-hole<br />

TA1JG750 TA1JG750 (400A max) TA2MG750 — TA4P750 f<br />

— — — 2TA3NG750<br />

3TA1JG750 3TA1JG750 (400A max) 3TA2MG750 3TA3NG750 —<br />

— — #2-600 kcmil; 3-hole 300-600 kcmil; 5; 6-hole<br />

— — — TA5P600 f<br />

TA6R600 f<br />

— — 3TA3MG600 d (Kit of 3) — —<br />

3/0-250 kcmil; 2-hole #2-600 kcmil; 2-hole 1/0-500 kcmil; 3-hole 1/0-500 kcmil; 4-hole —<br />

TC2JG250 — TC3MG500 — —<br />

— — — — —<br />

—<br />

— 3TC2LG600LD — 3TC4NG500 —<br />

3TC2LG600LN <br />

3/0-750 kcmil; 1-hole — — — 300-600 kcmil; 5-hole<br />

TC1JG750 — — — TC5R600 f<br />

#6-350 kcmil; 1-cable #6-350 kcmil; 2-cable 1/0-500 kcmil; 4-cable —<br />

— — — — —<br />

3CLJ350 6CLL350 (kit of 6) — 12CLN500 (kit of 12) —<br />

250-600 kcmil; 1-cable 250-750 kcmil; 1-cable — — —<br />

3CLJ600 3CLL750 — — —<br />

— — — — —<br />

250-600 kcmil; 2-cable<br />

6CLL600 (kit of 6) — — —<br />

— — — — —<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

#14-#4; 12-hole — — — —<br />

TA12JG04 — — — —<br />

3TA12JG04 — — — —<br />

#14-2/0; 6-hole — — — —<br />

TA6JG20 — — — —<br />

3TA6JG20 — — — —<br />

TA2JG250PT — TA3MG500PT — —<br />

— 3TA2LG600LNPT — 3TA4NG500PT —<br />

All lug kits include the nut keepers.<br />

a Mounted on Load Side Only.<br />

b Mounted on Line Side Only.<br />

c Required for 100% rated breakers. Requires 90°C cable<br />

sized at 75°C ampacity.<br />

d Requires extended modified shield.<br />

e Used only with LMAP1600 mounting base.<br />

f Used only with MBPG1600 or MBPG1601 mounting<br />

base.<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-213


External Accessories<br />

Revised on 11/30/19<br />

General<br />

For DG Frame<br />

For FG Frame<br />

150 A 250 A<br />

Description Catalog Number Catalog Number<br />

Handle Padlocking Device HPLF HPLF<br />

To padlock breaker toggle in the “OFF” position. Accepts up<br />

to 3 padlocks with 5–8 mm shackles.<br />

Handle Blocking Device HBDF HBDF<br />

For holding the handle in the “ON” position. Not a<br />

lockout/tagout device.<br />

Handle Padlocking<br />

Device<br />

Cable Interlock Mechanism<br />

Provides mechanical interlocking between 2 circuit-breakers -<br />

includes operator mechanism for one circuit breaker only. CBTF CBTF<br />

Combination with the next larger or smaller frame size is possible.<br />

Interlock Cable<br />

Cable only, to connect 2 circuit breakers.<br />

Cable length 18 in. .46m (recommended up to 250A) CBCF18 CBCF18<br />

Cable length 36 in. .91m (recommended from 400–800A) CBCM36 CBCM36<br />

Cable length 54 in. 1.37m (recommended from 1200–1600A) CBCP54 CBCP54<br />

Cable Interlock<br />

System<br />

Mounting Screw Kit<br />

Includes the necessary hardware to mount a circuit breaker to the<br />

user’s prepared surface<br />

Kit with 2 screws (SAE thread) MSKF2 MSKF2<br />

Kit with 4 screws (SAE thread) MSKF4 MSKF4<br />

Trip Adjustment Sealing Cover<br />

Includes a trip unit cover to prevent tampering or adjustment<br />

of trip settings. Seal not included. 3VL97008BL00 3VL97008BL00<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

7<br />

7-214<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Revised on 11/30/19<br />

For JG Frame For LG Frame For MG Frame For NG Frame For PG Frame<br />

400 A 600 A 800 A 1200 A 1600 A<br />

Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number<br />

HPLL HPLL HPLM HPLP HPLP<br />

HBDL HBDL HBDM HBDP HBDP<br />

CBTL CBTL CBTM CBTP CBTP<br />

— — — — —<br />

CBCM36 CBCM36 CBCM36 — —<br />

CBCP54 CBCP54 CBCP54 CBCP54 CBCP54<br />

— — — — —<br />

MSKL4 MSKL4 MSKM4 MSKP4 MSKP4<br />

3VL97008BL00 3VL97008BL00 3VL97008BL00 3VL97008BL00 3VL97008BL00<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-215


External Accessories<br />

Revised on 10/31/18<br />

Ground Sensors & Electronic Accessories<br />

For DG Frame<br />

For FG Frame<br />

150 A 250 A<br />

NGSF150<br />

NGSM600<br />

Description Catalog Number Catalog Number<br />

Neutral Current Transformer (Ground Sensor, N-pole)<br />

Neutral = 35/60A NGSD060 —<br />

Neutral = 100A NGSF100 NGSF100<br />

Neutral = 150A NGSF150 NGSF150<br />

Neutral = 250A — NGSJ250<br />

Neutral = 400A — —<br />

Neutral = 600A — —<br />

Neutral = 800A — —<br />

Neutral = 1000/1200A — —<br />

Neutral = 1600A — —<br />

Communications & Electronics<br />

Spare Flat<br />

Cable<br />

Power Stick - Hand held, battery operated power supply<br />

for LCD trip units. (Requires two 9V batteries.) Trip testing<br />

for both 555 & 586 trip units.<br />

EPSP18V<br />

EPSP18V<br />

Spare flat cable for Power Stick. COMPCA COMPCA<br />

Power Stick<br />

COM20 Profibus Communications Module with ZSI for<br />

electronic trip units (order cable separately)<br />

COMPRO20<br />

COMPRO20<br />

COM21 Modbus Communications Module with ZSI for<br />

electronic trip units (order cable separately)<br />

COMMOD21<br />

COMMOD21<br />

Cable for COM20/21, 1.5 m (4.9 ft) COMKIT3 COMKIT3<br />

Cable for COM20/21, 3.0 m (9.8 ft) COMKIT6 COMKIT6<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Com20 Profibus<br />

& Com21 Modbus<br />

Communications<br />

Module<br />

Door Cutouts & Extensions<br />

Addressing Plug - assigns a field bus address without a<br />

PC by plugging into COM20/21<br />

3UF79100AA000<br />

Cover Frame for Door Cutout<br />

For fixed or plug-in mounted circuit breakers. (IP30)<br />

2-Pole & 3-Pole BZLF3 BZLF3<br />

3UF79100AA000<br />

Cover Frame for<br />

Door Cutout<br />

For breakers with stored energy operator. (IP40) BZLFRHSE BZLFRHSE<br />

Circuit-breaker draw-out mounted and toggle handle operated.<br />

Kit includes cover frame (bezel) and escutcheon as needed. (IP40)<br />

(not for use with rotary handle or stored energy operator) BZLFBDC BZLFBDC<br />

THEL<br />

Toggle Handle Extension — —<br />

For spare or replacement. (One is included with each<br />

NG - PG frame.)<br />

THEP<br />

7-216<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category MCCB


Revised on 11/30/19<br />

<br />

For JG Frame For LG Frame For MG Frame For NG Frame For PG Frame<br />

400 A 600 A 800 A 1200 A 1600 A<br />

Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number<br />

— — — — —<br />

— — — — —<br />

— — — — —<br />

NGSJ250 — — — —<br />

NGSL400 NGSL400 — — —<br />

— NGSM600 NGSM600 — —<br />

— — NGSN800 NGSN800 —<br />

— — — NGSP120 NGSP120<br />

— — — — NGSP160<br />

EPSP18V EPSP18V EPSP18V EPSP18V EPSP18V<br />

COMPCA COMPCA COMPCA COMPCA COMPCA<br />

COMPRO20 COMPRO20 COMPRO20 COMPRO20 COMPRO20<br />

COMMOD21 COMMOD21 COMMOD21 COMMOD21 COMMOD21<br />

COMKIT4 COMKIT4 COMKIT5 COMKIT5 COMKIT5<br />

COMKIT7 COMKIT7 COMKIT8 COMKIT8 COMKIT8<br />

3UF79100AA000 3UF79100AA000 3UF79100AA000 3UF79100AA000 3UF79100AA000<br />

7<br />

BZLL3 BZLL3 BZLM3 BZLP3 BZLP3<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

BZLLRHSE BZLLRHSE BZLMRHSE BZLPRHSE BZLPRHSE<br />

BZLLBDC<br />

BZLLBDC<br />

THEL THEL THEM THEP THEP<br />

Product Category MCCB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-217


VL Circuit Breakers<br />

Accessory Locations<br />

Selection<br />

Locations of Internally Mounted Accessories<br />

Frame Family Left Pocket Right Pocket<br />

DG*, FG*, JG, LG<br />

150 to 600A<br />

Up to 3 Auxiliary Switches<br />

Up to 2 Auxiliary Switches + 1 Alarm Swich<br />

Shunt Trip or UVR or up to 3 Auxiliary Switches<br />

or up to 2 Auxiliary Switches + 1 Alarm Switch<br />

Shunt Trip or UVR or up to 3 Auxiliary Switches<br />

or up to 2 Auxiliary Switches + 1 Alarm Switch<br />

MG, NG, PG<br />

800 to 1600A<br />

Up to 4 Auxiliary Switches<br />

Up to 2 Auxiliary Switches + 2 Alarm Swiches<br />

Shunt Trip or UVR or up to 4 Auxiliary Switches<br />

Shunt Trip or UVR or up to 4 Auxiliary Switches<br />

* Except DG and FG breakers with Electronic Trip Units. Due to the location of the Magnetic Latch, the Left Pocket is not available for accessories.<br />

7<br />

Accessory Information<br />

b Aux. Switch is an Auxiliary Switch, 1A<br />

or 1B contact<br />

b Alarm Switch has 1A or 1B contact<br />

b UVR is an Undervoltage Release<br />

b The standard location for factory<br />

mounted Auxiliary and Alarm Switches<br />

is the Left Pocket<br />

Accessory Maximums<br />

DG, FG, JG, LG Maximum Accessories:<br />

b Maximum of six (6) switches total<br />

b DG, FG Maximum of two (2) Alarm<br />

Switches, one each in the Left and<br />

Right Pockets. JG, LG Max. of 1 Alarm,<br />

Left only<br />

MG, NG, PG Maximum Accessories:<br />

b Maximum of eight (8) switches total<br />

b Maximum of two (2) Alarm Switches,<br />

Left Pocket only<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

For applications using COMMOD20 and COMMOD21 for<br />

communication using Modbus or Profibus<br />

DG, FG<br />

COMKIT3 & COMKIT6 provide auxiliary<br />

contact kit. May add only one or two<br />

contact blocks for Alarm or Auxiliary<br />

function.<br />

JG, LG<br />

COMKIT4 & COMKIT7 provide auxiliary<br />

contact kit mounted in left pole pocket.<br />

One contact block can be added for<br />

Auxiliary function. Right pole pocket<br />

available for other release or an additional<br />

Auxiliary contact kit.<br />

MG, NG, PG<br />

COMKIT5 & COMKIT8 provide auxiliary<br />

contact kit mounted in Left pole pocket.<br />

Two contact blocks can be added for<br />

Auxiliary function and one for Alarm<br />

function. Right pole pocket available for<br />

other release or an additional Auxiliary<br />

Contact kit.<br />

7-218<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


VL Circuit Breakers<br />

Selection<br />

Suffix for factory mounted Switch Combinations<br />

Then add<br />

Device<br />

If the frame is: And you need these functions: this suffix: Catalog Number<br />

1 Alarm Switch<br />

DG, FG, JG or LG 1 NO Alarm A1 ASKL1<br />

1 NC Alarm<br />

DG, FG, JG or LG<br />

2 Aux. Switches<br />

1 NO + 1 NC Aux. Contacts<br />

A2<br />

ASKL2<br />

2 Aux. + 1 Alarm Switches<br />

DG, FG, JG or LG 1NO + 1NC Aux. and 1NC Alarm A3 ASKL3<br />

2NO Aux. and 1NC Alarm<br />

2 Aux. + 2 Alarm Switches<br />

MG, NG or PG<br />

1NO + 1NC Aux. and 1NO + 1NC Alarm<br />

2NO Aux. and 2NC Alarm<br />

A3<br />

ASKP3<br />

2NC Aux. and 2NO Alarm<br />

MG, NG or PG<br />

4 Aux. Switches<br />

2NO + 2NC Aux.<br />

A4<br />

ASKP4<br />

Suffix for factory mounted Shunt Trips<br />

Then add<br />

Device<br />

If the frame is: And you need these functions: this suffix: Catalog Number<br />

24V DC RB STRLB24DC<br />

48-60V DC RC STRLC60DC<br />

110-127V DC RD STRLD125DC<br />

DG, FG, JG or LG<br />

220-250V DC RE STRLE250DC<br />

48-60V AC RM STRLM60<br />

110-127V AC RN STRLN120<br />

208-277V AC RS STRLS277<br />

380-600V AC RV STRLV600<br />

24V DC RB STRPB24DC<br />

48-60V DC RC STRPC60DC<br />

110-127V DC RD STRPD125DC<br />

MG, NG or PG<br />

220-250V DC RE STRPE250DC<br />

48-60V AC RM STRPM60<br />

110-127V AC RN STRPN120<br />

208-277V AC RS STRPS277<br />

380-600V AC RV STRPV600<br />

Suffix for factory mounted Undervoltage Releases<br />

Then add<br />

Device<br />

If the frame is: And you need these functions: this suffix: Catalog Number<br />

12V DC UA UVRLA12DC<br />

24V DC UB UVRLB24DC<br />

48V DC UC UVRLC48DC<br />

60V DC UG UVRLG60DC<br />

110-127V DC UD UVRLD125DC<br />

220-250V DC UE UVRLE250DC<br />

DG, FG, JG or LG 24V AC UK UVRLL24<br />

110-127V AC UN UVRLN120<br />

220-240V AC UR UVRLR240<br />

208V AC UP UVRLP208<br />

277V AC US UVRLS277<br />

380-415V AC UT UVRLT415<br />

440-480V AC UU UVRLU480<br />

12V DC UA UVRPA12DC<br />

24V DC UB UVRPB24DC<br />

48V DC UC UVRPC48DC<br />

60V DC UG UVRPG60DC<br />

110-127V DC UD UVRPD125DC<br />

220-250V DC UE UVRPE250DC<br />

MG, NG or PG 110-127V AC UN UVRPN120<br />

220-240V AC UR UVRPR240<br />

208V AC UP UVRPP208<br />

277V AC US UVRPS277<br />

380-415V AC UT UVRPT415<br />

440-480V AC UU UVRPU480<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-219


Technical Data<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

DG FG JG LG MG NG PG<br />

Max rated continuous current 150 250 400 600 800 1200 1600<br />

Rated operational voltage<br />

NEMA V AC 600 600 600 600 600 600 600<br />

IEC V AC 690 690 690 690 690 690 690<br />

Rated Impulse Withstand Voltage<br />

Main conducting paths kV 8 8 8 8 8 8 8<br />

Auxiliary circuits kV 4 4 4 4 4 4 4<br />

Ambient Temperature Range ºC -25 to +75 -25 to +75 -25 to +75 -25 to +75 -25 to +75 -25 to +75 -25 to +75<br />

High Ambient Derating (thermal-mag.) 50ºC 93% 93% 93% 93% 95% 95% 95%<br />

60ºC 86% 86% 86% 86% 86% 86% 80%<br />

70ºC 80% 80% 80% 80% 80% 80% 74%<br />

Operating Cycles 20,000 20,000 20,000 10,000 5,000 3,000 3,000<br />

Max switching rate (per hour) 120 120 120 60 60 30 30<br />

Power loss (at max. rated current)<br />

Thermal-magnetic W 15 – 48 32 – 80 60 – 175 85 – 230 170 – 250 150 – 220 200 – 260<br />

Electronic trip unit W 40 60 90 160 250 210 260<br />

IEC 1<br />

Time constant t = 10 ms<br />

1 current path 2 current paths 3 current paths<br />

in series in series<br />

Up to 250V DC 440V DC 600V DC — — — — — — —<br />

NEMA<br />

Time constant t = 8 ms<br />

2 poles switching 1 current path<br />

250V DC Max. 2 30 30 30 30 42 42 42<br />

3 poles switching 2 current paths in series<br />

500V DC Max. 2 18 25 35 35 65 65 65<br />

Accessories<br />

Auxiliary/ Alarm Switch<br />

Current rating (1 or 2 switches) 10 10 10 10 10 10 10<br />

Current rating (3 or 4 same switch) A 5 5 5 5 5 5 5<br />

Shunt Trip<br />

Pick-up voltage V 0.7 – 1.1 0.7 – 1.1 0.7 – 1.1 0.7 – 1.1 0.7 – 1.1 0.7 – 1.1 0.7 – 1.1<br />

Power Consumption (short-time) at:<br />

48 – 60 V AC VA 401 – 501 401 – 501 401 – 501 401 – 501 401 – 501 401 – 501 401 – 501<br />

110 – 127 V AC VA 424 – 489 424 – 489 424 – 489 424 – 489 424 – 489 424 – 489 424 – 489<br />

208 – 277 V AC VA 533 – 736 533 – 736 533 – 736 533 – 736 533 – 736 533 – 736 533 – 736<br />

380 – 600 V AC VA 408 – 645 408 – 645 408 – 645 408 – 645 408 – 645 408 – 645 408 – 645<br />

24 V DC W 594 594 594 594 594 594 594<br />

48 – 60 V DC W 740 – 925 740 – 925 740 – 925 740 – 925 740 – 925 740 – 925 740 – 925<br />

110 –127 V DC W 559 – 648 559 – 648 559 – 648 559 – 648 559 – 648 559 – 648 559 – 648<br />

220 – 250 V DC W 722 – 820 722 – 820 722 – 820 722 – 820 722 – 820 722 – 820 722 – 820<br />

Max. Operating time ms 50 50 50 50 50 50 50<br />

1 Consult Siemens for short circuit values.<br />

2 Review individual frame and type values.<br />

7-220<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Technical Data<br />

Revised on 05/31/18<br />

DG FG JG LG MG NG PG<br />

Undervoltage Trip<br />

Drop voltage (percentage) V 35% – 70% 35% – 70% 35% – 70% 35% – 70% 35% – 70% 35% – 70% 35% – 70%<br />

Pick-up voltage (percentage) V 70% – 85% 70% – 85% 70% – 85% 70% – 85% 70% – 85% 70% – 85% 70% – 85%<br />

Power consumption (continuous) at:<br />

110 – 127 V AC VA 1 1 1 1 1.1 1.1 1.1<br />

220 – 250 V AC VA 2.1 2.1 2.1 2.1 2.1 2.1 2.1<br />

208 V AC VA 1.2 1.2 1.2 1.2 1.2 1.2 1.2<br />

277 V AC VA 1.4 1.4 1.4 1.4 1.4 1.4 1.4<br />

380 – 415 V AC VA 1.9 1.9 1.9 1.9 1.9 1.9 1.9<br />

440 – 480 V AC VA 2.2 2.2 2.2 2.2 2.2 2.2 2.2<br />

500 – 525 V AC VA 2.5 2.5 2.5 2.5 2.5 2.5 2.5<br />

600 V AC VA 2.8 2.8 2.8 2.8 2.8 2.8 2.8<br />

Max. opening time ms 50 50 50 50 50 50 50<br />

Motorized Operating Mechanism<br />

Motor with stored energy mechanism<br />

(synchronizable) X X X X<br />

Motor Operator X X X<br />

Max. switching rate (per hour) 120 120 120 60 60 30 30<br />

Command duration ms 20 – 50 20 – 50 20 – 50 20 – 50 20 – 50 — —<br />

Closing time ms


Technical Data<br />

Unusual Operating Conditions<br />

Revised on 11/30/17<br />

Reference<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Note: The information provided on<br />

this and the next page is intended for<br />

reference and recommendation only.<br />

Because several variables can act on<br />

a circuit breaker’s performance at the<br />

same time, the data below is based less<br />

on controlled testing, than on experience<br />

and engineering judgment. Contact<br />

Siemens for further information on<br />

special conditions and treatment.<br />

High Ambient Temperatures<br />

Because thermal-magnetic trip breakers<br />

are temperature sensitive and calibrated<br />

for a specific ambient of 40° C (104°<br />

F) (average enclosure temperature), a<br />

higher ambient will cause the breaker<br />

to trip at lower current than its nameplate<br />

rating, in other words, causing<br />

the breaker to “derate” (see Table 1).<br />

Similarly, the current carrying capacity<br />

of a circuit conductor is based upon a<br />

certain ambient temperature, a higher<br />

ambient will reduce its current carrying<br />

capacity, causing it to “derate.” Thus,<br />

with a fluctuating temperature, a thermal-magnetic<br />

breaker will derate nearly<br />

parallel with its connected circuit conductors<br />

and maintain close circuit protection.<br />

If the application temperature<br />

exceeds 40° C (104° F) and is known,<br />

either a breaker specially calibrated for<br />

the higher ambient or one oversized<br />

according to Table 1 may be selected.<br />

In a case such as this, the circuit conductors<br />

should be oversized as well.<br />

Siemens Electronic Trip Unit Breakers<br />

are insensitive to temperature changes.<br />

However, they do include circuitry to<br />

protect the components from abnormally<br />

high temperatures.<br />

Table 1 – Temperature derating data for thermal-magnetic breakers<br />

Reference Ampere<br />

Rating at<br />

40° C (104° F)<br />

Ampere Rating at:<br />

50°C<br />

(122° F)<br />

60° C<br />

(140° F)<br />

50 46 42<br />

60 56 52<br />

70 65 60<br />

90 84 78<br />

100 94 87<br />

125 114 100<br />

150 136 120<br />

175 159 140<br />

200 182 160<br />

225 205 180<br />

250 235 220<br />

300 276 252<br />

350 325 301<br />

400 372 340<br />

500 468 435<br />

600 564 525<br />

700 658 613<br />

800 754 704<br />

900 828 749<br />

1000 900 825<br />

1200 1090 1000<br />

1400 1304 1148<br />

1600 1500 1320<br />

Siemens Breaker Frames<br />

DG<br />

FG<br />

JG<br />

LG<br />

MG<br />

NG<br />

PG<br />

Altitude<br />

Reduced air density at altitudes greater<br />

than 6600 ft. (2000 meters) affects the<br />

ability of a molded case circuit breaker<br />

to transfer heat and interrupt faults.<br />

Therefore, circuit breakers applied at<br />

these altitudes should have interrupting,<br />

insulation and continuous currents<br />

derated as indicated in Figure 1.<br />

Figure 1 – Altitude adjustment<br />

7-222<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Technical Data<br />

Unusual Operating Conditions<br />

Unusual Operating Conditions 400 Hz Systems<br />

Circuit Breaker Derating Required<br />

This table lists the maximum continuous<br />

current carrying capacity for<br />

Siemens breakers at 400Hz. Due to<br />

the increased resistance of the copper<br />

sections resulting from the skin effect<br />

produced by eddy currents at these<br />

frequencies, circuit breakers in many<br />

cases require derating. The thermal<br />

derating on these devices is based<br />

upon 100%, three phase application in<br />

open air in a maximum of 40°C (104° F)<br />

with 48 in. (1219 mm) of the specified<br />

cable or bus at the line and load<br />

side. Additional derating of not less<br />

than 20% will be required if the circuit<br />

breaker is to be utilized in an enclosure.<br />

Further derating may be required<br />

if the enclosure ambient temperature<br />

exceeds 40°C(104° F).<br />

Cable and Bus Sizing<br />

The cable and bus sizes to be utilized<br />

at 400Hz are not based on standard<br />

National Electric Codes tables for 60Hz<br />

application. Larger cross sections are<br />

necessary at 400Hz. All bus bars<br />

specified are based upon mounting the<br />

bars in the vertical plane to allow maximum<br />

air flow. All bus bars are spaced<br />

at a minimum of 0.25 in. (6 mm) apart.<br />

Mounting of bus bars in the horizontal<br />

plane will necessitate additional drafting.<br />

Edgewise orientation of the bus may<br />

change the maximum ratings indicated.<br />

If additional information is required for<br />

other connections of cable or bus, contact<br />

Siemens for information.<br />

Reference<br />

Application Recommendations<br />

It is recommended that temperatures<br />

be measured on the line and load terminals<br />

or T-connectors of the center pole.<br />

These are usually the hottest terminals<br />

with a balanced load. A maximum<br />

temperature of 75°C (35°C over a maximum<br />

ambient of 40°C) would verify<br />

the particular application. Temperature<br />

profiles taken on these breakers can<br />

be correlated to ensure that the hottest<br />

points within the breaker are within the<br />

required temperature limits.<br />

Interrupting Rating<br />

Circuit breakers used in 400 Hz systems<br />

are limited to a 5000 A interrupting<br />

rating. If higher ratings are required,<br />

consult Siemens.<br />

Breaker<br />

type<br />

DG<br />

FG<br />

JG<br />

JG<br />

100%<br />

Rated<br />

LG<br />

Maximum continuous ampere rating<br />

at 40°C (104°F) <br />

60HZ 400HZ<br />

Open air Open air derating<br />

Enclosed after<br />

75°C (167F)<br />

Copper<br />

cable per pole<br />

No of<br />

pieces<br />

Wire size<br />

50 48 38 1 #8<br />

60 57 46 1 #6<br />

70 63 50 1 #4<br />

80 72 58 1 #4<br />

90 80 64 1 #3<br />

100 90 72 1 #3<br />

110 95 75 1 #2<br />

125 105 84 1 #1<br />

150 125 100 1 #1/0<br />

100 90 72 1 #3<br />

110 95 75 1 #2<br />

125 105 84 1 #1<br />

150 125 100 1 #1/0<br />

175 140 112 1 #2/0<br />

200 160 128 1 #3/0<br />

225 180 144 1 #4/0<br />

250 200 160 1 250 kcmil<br />

250 210 168 1 250 kcmil<br />

300 240 192 1 350 kcmil<br />

350 260 208 1 500 kcmil<br />

400 300 240 2 #2/0<br />

250 210 210 1 250 kcmil<br />

300 240 240 1 350 kcmil<br />

350 260 260 1 500 kcmil<br />

400 300 300 2 #3/0<br />

400 300 240 2 #3/0<br />

500 375 300 2 250 kcmil<br />

600 420 336 2 350 kcmil<br />

Breaker<br />

type<br />

LG<br />

MG<br />

MG<br />

100%<br />

Rated<br />

NG<br />

NG<br />

100%<br />

Rated<br />

PG<br />

PG 100%<br />

Rated<br />

Maximum continuous ampere rating<br />

at 40°C (104°F) <br />

60HZ 400HZ<br />

Open air Open air derating<br />

Enclosed after<br />

75°C (167F)<br />

Copper<br />

cable per pole<br />

No of<br />

pieces<br />

Wire size<br />

400 300 240 2 #3/0<br />

500 375 300 2 250 kcmil<br />

600 420 336 2 350 kcmil<br />

600 430 360 2 350 kcmil<br />

700 500 400 3 250 kcmil<br />

800 560 448 3 300 kcmil<br />

600 430 430 2 350 kcmil<br />

700 500 500 3 250 kcmil<br />

800 560 560 3 300 kcmil<br />

800 560 448 3 300 kcmil<br />

900 600 480 3 350 kcmil<br />

1000 650 520 3 400 kcmil<br />

1200 780 624 4 350 kcmil<br />

900 600 600 3 350 kcmil<br />

1000 650 650 3 400 kcmil<br />

1200 780 780 4 350 kcmil<br />

1200 780 624 4 400 kcmil<br />

1400 850 680 4 500 kcmil<br />

1600 960 768 5 500 kcmil<br />

1200 780 780 4 400 kcmil<br />

1400 850 850 4 500 kcmil<br />

1600 960 960 5 500 kcmil<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

The information provided on this page is intended for<br />

reference and recommendation only. Because several<br />

variables can act on a circuit breaker’s performance at<br />

the same time, the data above is based less on controlled<br />

testing, than on experience and engineering<br />

judgment.Contact Siemens for further information on<br />

special conditions and treatment.<br />

Additional derating may be required if the ambient<br />

temperature is greater than 40°C (104°F).<br />

Calculated after derating to compensate for the heating<br />

of the copper conductor, caused by the skin effect<br />

generated by eddy currents produced at 400/415HZ.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-223


Molded Case Circuit Breakers<br />

Series Connected Short Circuit Ratings<br />

Revised on 03/25/17<br />

General<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

The term “Series Connected Short<br />

Circuit Rating” refers to the application of<br />

series circuit breakers in a combination<br />

that allows downstream breakers to have<br />

lower individual interrupting ratings than<br />

the available fault current.<br />

240V Breaker Series Ratings<br />

Series<br />

Rating<br />

kAIR<br />

22000<br />

Main Breaker<br />

Branch Breaker<br />

Type<br />

Max.<br />

Amperes Type<br />

QPH, BQH,<br />

BLH<br />

QPMH<br />

QJH2<br />

QPPH<br />

QRH2<br />

42000 QJ2H<br />

65000<br />

HQP, HBQ,<br />

HBL<br />

70 (1P)<br />

125 (2P)<br />

100 (3P)<br />

QP, BQ, BL<br />

This is permitted as long as the series<br />

combination has been tested and certified<br />

by UL.<br />

The tables on these pages list specific<br />

main and branch breaker combinations<br />

that may be used for the short circuit<br />

interrupting ratings shown.<br />

Number<br />

of Poles Voltage Amperes<br />

1<br />

2<br />

3<br />

120/240<br />

240<br />

240<br />

15-70<br />

15-125<br />

15-100<br />

QE, BLE, QPF, BLF 2 120/240 15-60<br />

QE, BLE, BE, QPF,<br />

BQF, BLF QPF2, BLF2<br />

1 240 15-30<br />

QT 1, 2 120/240 15-40<br />

QG, BG, BLG 1, 2 120/240 15-30<br />

BAF, QAF, QAF2, BAF2,<br />

QFGA2, BFGA2<br />

1 120 15-20<br />

BAF, QAF 2 120/240 15-20<br />

QP 1<br />

120 15-25<br />

120/240 35-70<br />

2 120/240 15-25<br />

35-125<br />

200 (2P)<br />

1<br />

QE, QPF<br />

120/240 15-30<br />

2<br />

15-60<br />

QAF, BAF<br />

1 120 15-20<br />

2 120/240 15-20<br />

QT 2 120/240 15-30<br />

1 120/240 15-70<br />

QP, BQ, BL<br />

2 240 15-125<br />

3 240 60-100<br />

QPF, BQF, BLF, BG, BLG<br />

1 120 15-30<br />

QE, BE, BLE, QPF2, BLF2<br />

225<br />

QPF, BLF, BG, BLG, QE<br />

(2P, 3P)<br />

2 120/240 15-60<br />

BE, BLE<br />

BAF, QAF, QAF2, BAF2 1 120 15-20<br />

BAF, QAF 2 120/240 15-20<br />

QT 1, 2 120/240 15, 20, 40<br />

QR2 2,3 240 100-225<br />

225 (2P)<br />

250<br />

(2, 3P)<br />

225<br />

(2, 3P)<br />

70 (1P)<br />

125 (2P)<br />

100 (3P)<br />

1<br />

2<br />

120/240<br />

120/240<br />

15-70<br />

15-125<br />

QP, BQ, BL<br />

QE, BLE, BE, QPF, BQF,<br />

BLF, QPF2, BLF2<br />

1 120 15-30<br />

QE, BLE, BE, QPF, BLF 2 120/240 15-60<br />

BAF, QAF, QAF2, BAF2 1 120 15-20<br />

BAF, QAF 2 120/240 15-20<br />

QPP 2 120/240 125-200<br />

QT 1, 2 120/240 15-40<br />

QP,BQ,BL<br />

1<br />

2<br />

2<br />

3<br />

1<br />

2<br />

120/240 15-70<br />

120/240 15-125<br />

240 15-125<br />

240 15-100<br />

120 15-30<br />

120/240 15-30<br />

QG, BG, BLG<br />

QT 1,2 120/240 15-50<br />

QFGA2, BFGA2, QAF2,<br />

BAF2, QAF, BAF<br />

1 120 15-20<br />

QAF, BAF 2 120/240 15-20<br />

QPF2, BLF2, QPF, BQF,<br />

BLF, QE, BLE, BE<br />

1 120 15-30<br />

QPF, BLF, QE, BLE 2 120/240 15-60<br />

QN, QNR 2 120/240 150-200<br />

QS 2 120/240 100-225<br />

QR2 2 120/240 100-250<br />

QP, BQ, BL<br />

1<br />

2<br />

120/240 15-70<br />

120/240 15-125<br />

3 240 60-100<br />

QPH, BQH, BLH<br />

1<br />

2<br />

120/240 15-70<br />

120/240 15-125<br />

3 240 15-100<br />

QR2, QRH2 2,3 240 100-225<br />

QJH2 2, 3 240 60-225<br />

QP, BQ, BL,<br />

QPH, BQH, BLH<br />

QPF, BQF, BLF, BE, QPHF,<br />

BQHF, BLHF, QEH, BLEH,<br />

QE, BLE, QPF2, BLF2,<br />

QPHF2, BLHF2, QPHF2,<br />

BLHF2<br />

1<br />

2<br />

3<br />

120/240<br />

240<br />

240<br />

15-70<br />

15-125<br />

15-100<br />

1 120 15-30<br />

QEH, BLEH, QE, QPHF,<br />

BLHF, BLE, QPF, BLF<br />

2 120/240 15-60<br />

QT 1, 2 120/240 15-40<br />

QG, BG, BLG 1, 2 120/240 15-30<br />

Series<br />

Rating<br />

kAIR<br />

65000<br />

(cont.)<br />

Main Breaker<br />

Branch Breaker<br />

Type<br />

Max.<br />

Amperes Type<br />

HQP, HBQ,<br />

HBL<br />

ED4,<br />

ED4, ED6<br />

NDGA,<br />

NDGB<br />

HQPP<br />

FD6-A,<br />

FXD6-A<br />

NFGA,<br />

NFGB<br />

70 (1P)<br />

125 (2P)<br />

100 (3P)<br />

100<br />

(1P)<br />

125<br />

(2P, 3P)<br />

150<br />

(2P, 3P)<br />

225<br />

(2P)<br />

250<br />

(2P,3P)<br />

No substitutions are permitted. All combinations<br />

shown have been tested and<br />

are UL Listed. This information is provided<br />

as a reference tool only. For verification<br />

of specific combination ratings<br />

consult the UL Recognized<br />

Components Directory.<br />

240V Breaker Series Ratings (continued)<br />

HQR2<br />

BAF, QAF, BQAF, QAF2,<br />

BAF2, QAFH2, BAFH2,<br />

QFGA2, BFGA2, QF-<br />

GAH2, BFGAH2<br />

Number<br />

of Poles Voltage Amperes<br />

1 120 15-20<br />

BAF, QAF 2 120/240 15-20<br />

1 120/240 15-70<br />

QP, BQ, BL<br />

2 240 15-125<br />

QPH, BQH, BLH<br />

3 240 15-100<br />

QPHF, BQHF, BLHF, QPF,<br />

BQF, BLF, QE, QEH, BLEH,<br />

1<br />

BE, BLE, QPF2, BLF2,<br />

120 15-30<br />

QPHF2, BLHF2<br />

QEH, BLEH, QE, QPHF,<br />

BLHF,BLE, QPF, BLF<br />

2 120/240 15-60<br />

QAF2, BAF2, BAF, QAF,<br />

BQAF, QAFH2, BAFH2,<br />

QAFH, BQAFH, BAFH, 1 120 15-20<br />

QFGA2, BFGA2, QF-<br />

GAH2, BFGAH2<br />

QAF, BAF, QAFH, BAFH 2 120/240 15-20<br />

ED2 1,2,3 120/240 15-100<br />

QT 1,2 120/240 15-40<br />

1<br />

QPH, BQH, BLH<br />

2<br />

3<br />

QP, BQ, BL,<br />

1<br />

QPH, BQH, BLH<br />

2<br />

QPF, BQF, BLF, QPHF,<br />

BQHF, BLHF, QEH, BLEH,<br />

QE, BLE, BE, BLF2, QPF2,<br />

QFGA2, BFGA2<br />

QEH, BLEH, QE, QPHF,<br />

BLHF, BLE, QPF, BLF<br />

BAF, QAF, BQAF, QAF2,<br />

BAF2, QAFH2, BAFH2,<br />

QAFH, BQAFH, QFGAH2,<br />

BFGAH2<br />

120/240<br />

240<br />

240<br />

120/240<br />

120/240<br />

15-70<br />

15-125<br />

15-100<br />

15-70<br />

15-125<br />

1 120/240 15-30<br />

2 120/240 15-60<br />

1 120 15-20<br />

BAF, QAF, QAFH, BAFH 2 120/240 15-20<br />

QT 1, 2 120 15-40<br />

QPPH, QPP 2 120/240 125-200<br />

QP, BQ, BL<br />

QPH, BQH, BLH<br />

1<br />

2<br />

3<br />

120/240 15-70<br />

120/240 15-125<br />

240 15-100<br />

QPF, QPHF, BLF, BLHF 1,2 120/240 15-60<br />

QPF2, BLF2, QPHF2,<br />

BLHF2<br />

1<br />

2<br />

120<br />

120/240<br />

15-30<br />

15-60<br />

QAF, BAF, QAF2, BAF2,<br />

BQAF, QAFH2, BAFH2,<br />

QAFH, BQAFH, BAFH, 1 120 15-20<br />

QFGA2, BFGA2, QF-<br />

GAH2, BFGAH2<br />

QAF, BAF, QAFH, BAFH 2 120/240 15-20<br />

QR2, QRH2 2,3 240 100-225<br />

QJ2H, QJ2, QJH2 2,3 240 60-225<br />

QPPH 2 120/240 125-225<br />

1 120/240 15-70<br />

QPH, BQH, BLH<br />

2 120/240 15-125<br />

3 240 15-100<br />

QR2, QRH2 2,3 240 100-250<br />

QP, BQ, BL<br />

1<br />

2<br />

3<br />

120/240 15-70<br />

120/240 15-125<br />

240 15-100<br />

QT 1,2 120/240 15-50<br />

QFGA2, BFGA2, QAF2,<br />

1 120 15-20<br />

BAF2, QAF, BAF<br />

QAF, BAF 2 120/240 15-20<br />

QPF2, BLF2, QPF, BQF,<br />

1 120 15-30<br />

BLF, QE, BLE, BE<br />

QPF, BLF, QE, BLE 2 120/240 15-60<br />

QPH, BQH, BLH<br />

1<br />

2<br />

3<br />

120/240 15-70<br />

120/240 15-125<br />

240 15-100<br />

7-224<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Molded Case Circuit Breakers<br />

Series Connected Short Circuit Ratings<br />

Revised on 02/06/18<br />

General<br />

240V Breaker Series Ratings (continued)<br />

Series<br />

Rating<br />

kAIR<br />

65000<br />

(cont.)<br />

Main Breaker<br />

Branch Breaker<br />

Type<br />

Max.<br />

Amperes Type<br />

Number<br />

of Poles Voltage Amperes<br />

QFGAH2, BFGAH2, QAFH2,<br />

1<br />

BAFH2, QAFH, BAFH<br />

120 15-20<br />

QAFH, BAFH 2 120/240 15-20<br />

QPHF, BLHF, QPHF2,<br />

HQR2 250<br />

1 120 15-30<br />

BLHF2, QEH, BLEH<br />

(cont.) (2P, 3P)<br />

QEH, BLEH, QPHF, BLHF 2 120/240 15-60<br />

QN, QNH, QNR, QNRH 2 120/240 150-200<br />

QS, QSH, QSHH 2 120/240 100-225<br />

QR2, QRH2 2,3 240 100-250<br />

JXD2-A,<br />

JD6-A<br />

JXD6-A<br />

NJGA/<br />

NJJA<br />

SJD6-A<br />

SJD6-B<br />

HJD6-A,<br />

HJXD6<br />

LD6-A<br />

LXD6-A<br />

NLGA,<br />

NLGB<br />

SLD6-A<br />

SLD6-B<br />

HLD6-A,<br />

HLXD6-A<br />

MD6,<br />

MXD6<br />

400<br />

(2P, 3P)<br />

600<br />

(2P, 3P)<br />

800<br />

(2P, 3P)<br />

QPH, BQH, BLH<br />

1<br />

2<br />

3<br />

120/240<br />

120/240<br />

240<br />

15-70<br />

15-125<br />

15-100<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, QFGA2, BFGA2, 1 120 15-20<br />

QFGAH2, BFGAH2<br />

QPF2, BLF2, QPHF2, BLHF2 1 120 15-30<br />

QR2, QRH2 2,3 240 100-250<br />

QJ2H, QJH2 2,3 240 60-225<br />

QPH, BQH, BLH<br />

1<br />

2<br />

3<br />

120/240 15-70<br />

120/240 15-125<br />

240 15-100<br />

QR2, QRH2 2,3 240 100-250<br />

QN, QNH 2 120/240 150-200<br />

QNR, QNRH 2 120/240 150-200<br />

QPH, BQH, BLH<br />

1<br />

2<br />

3<br />

120/240<br />

120/240<br />

240<br />

15-70<br />

15-125<br />

15-100<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, QFGA2, BFGA2, 1 120 15-20<br />

QFGAH2, BFGAH2<br />

QPF2, BLF2, QPHF2, BLHF2 1 120 15-30<br />

QR2, QRH2 2,3 240 100-250<br />

QPH<br />

1<br />

2<br />

3<br />

120/240<br />

120/240<br />

240<br />

15-70<br />

15-125<br />

15-100<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, QFGA2, BFGA2, 1 120 15-20<br />

QFGAH2, BFGAH2<br />

QPF2, BLF2, QPHF2, BLHF2 1 120 15-30<br />

1 120/240 15-70<br />

QPH, BQH, BLH<br />

2 120/240 15-125<br />

3 240 15-100<br />

QR2, QRH2 2,3 240 100-250<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, QFGA2, BFGA2, 1 120 15-20<br />

QFGAH2, BFGAH2<br />

QPF2, BLF2, QPHF2, BLHF2 1 120 15-30<br />

QJ2H, QJH2 2,3 240 60-225<br />

1 120/240 15-70<br />

QPH, BQH, BLH<br />

2 120/240 15-125<br />

3 240 15-100<br />

QR2, QRH2 2,3 240 100-250<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, QFGA2, BFGA2, 1 120 15-20<br />

QFGAH2, BFGAH2<br />

QPF2, BLF2, QPHF2, BLHF2 1 120 15-30<br />

QN, QNH 2 120/240 150-200<br />

QNR, QNRH 2 120/240 150-200<br />

QPH, BQH, BLH<br />

1<br />

2<br />

3<br />

120/240<br />

120/240<br />

240<br />

15-70<br />

15-125<br />

15-100<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, QFGA2, BFGA2, 1 120 15-20<br />

QFGAH2, BFGAH2<br />

QPF2, BLF2, QPHF2,<br />

BLHF2<br />

1 120 15-30<br />

QR2, QRH2 2,3 240 100-250<br />

QPH<br />

1<br />

2<br />

3<br />

120/240<br />

120/240<br />

240<br />

15-70<br />

15-125<br />

15-100<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, QFGA2, BFGA2, 1 120 15-20<br />

QFGAH2, BFGAH2<br />

QPF2, BLF2, QPHF2, BLHF2 1 120 15-30<br />

QPH, BQH, BLH<br />

1<br />

2<br />

3<br />

120/240<br />

120/240<br />

240<br />

15-70<br />

15-125<br />

15-100<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, QFGA2, BFGA2, 1 120 15-20<br />

QFGAH2, BFGAH2<br />

QPF2, BLF2, QPHF2, BLHF2 1 120 15-30<br />

QR2, QRH2 2,3 240 100-250<br />

240V Breaker Series Ratings (continued)<br />

Series<br />

Rating<br />

kAIR<br />

65000<br />

(cont.)<br />

Main Breaker<br />

Branch Breaker<br />

Type<br />

Max.<br />

Amperes Type<br />

NMG,<br />

HMG<br />

SMD6<br />

SMD6-B<br />

HMXD6<br />

HMD6<br />

ND6, NXD<br />

NNG, HNG<br />

SND6<br />

SND6-B<br />

HND6,<br />

HNXD6<br />

SPD6,<br />

SPD6-B,<br />

PD6, PXD6<br />

NPG<br />

HPD6,<br />

HPXD6<br />

HRD6,<br />

HRXD6<br />

RD6, RXD6<br />

800<br />

(2P, 3P)<br />

(cont.)<br />

1200<br />

(2P, 3P)<br />

1600<br />

(2P, 3P)<br />

2000<br />

(2P, 3P)<br />

QPH, BQH, BLH<br />

Number<br />

of Poles Voltage Amperes<br />

1<br />

2<br />

3<br />

120/240 15-70<br />

120/240 15-125<br />

240 15-100<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, QFGA2, BFGA2, 1 120 15-20<br />

QFGAH2, BFGAH2<br />

QPF2, BLF2, QPHF2, BLHF2 1 120 15-30<br />

QR2, QRH2 2,3 240 100-250<br />

QN, QNH 2 120/240 150-200<br />

QNR, QNRH 2 120/240 150-200<br />

QPH, BQH, BLH<br />

1<br />

2<br />

3<br />

120/240<br />

120/240<br />

240<br />

15-70<br />

15-125<br />

15-100<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, QFGA2, BFGA2, 1 120 15-20<br />

QFGAH2, BFGAH2<br />

QPF2, BLF2, QPHF2, BLHF2 1 120 15-30<br />

QR2, QRH2 2,3 240 100-250<br />

QPH<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, QFGA2, BFGA2,<br />

QFGAH2, BFGAH2<br />

QPF2, BLF2, QPHF2,<br />

BLHF2<br />

QPH, BQH, BLH<br />

1<br />

2<br />

3<br />

120/240<br />

120/240<br />

240<br />

15-70<br />

15-125<br />

15-100<br />

1 120 15-20<br />

1 120 15-30<br />

1<br />

2<br />

3<br />

120/240 15-70<br />

120/240 15-125<br />

240 15-100<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, QFGA2, BFGA2, 1 120 15-20<br />

QFGAH2, BFGAH2<br />

QPF2, BLF2, QPHF2,<br />

BLHF2<br />

1 120 15-30<br />

QR2, QRH2 2,3 240 100-250<br />

QPH, BQH, BLH<br />

1<br />

2<br />

3<br />

120/240<br />

120/240<br />

240<br />

15-70<br />

15-125<br />

15-100<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, QFGA2, BFGA2, 1 120 15-20<br />

QFGAH2, BFGAH2<br />

QPF2, BLF2, QPHF2,<br />

BLHF2<br />

1 120 15-30<br />

QR2, QRH2 2,3 240 100-250<br />

QN, QNH 2 120/240 150-200<br />

QNR, QNRH 2 120/240 150-200<br />

QPH, BQH, BLH<br />

1<br />

2<br />

3<br />

120/240<br />

120/240<br />

240<br />

15-70<br />

15-125<br />

15-100<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, QFGA2, BFGA2, 1 120 15-20<br />

QFGAH2, BFGAH2<br />

QPF2, BLF2, QPHF2,<br />

BLHF2<br />

1 120 15-30<br />

QR2, QRH2 2,3 240 100-250<br />

QPH<br />

1<br />

2<br />

3<br />

120/240<br />

120/240<br />

240<br />

15-70<br />

15-125<br />

15-100<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, QFGA2, BFGA2, 1 120 15-20<br />

QFGAH2, BFGAH2<br />

QPF2, BLF2, QPHF2,<br />

BLHF2<br />

1 120 15-30<br />

1 120/240 15-70<br />

QPH, BQH, BLH<br />

2 120/240 15-125<br />

3 240 15-100<br />

QR2, QRH2 2,3 240 100-250<br />

QPH, BQH, BLH<br />

1<br />

2<br />

3<br />

120/240 15-70<br />

120/240 15-125<br />

240 15-100<br />

QR2, QRH2 2,3 240 100-250<br />

QN, QNH 2 120/240 150-200<br />

QNR, QNRH 2 120/240 150-200<br />

QPH<br />

QPH<br />

1<br />

2<br />

3<br />

1<br />

2<br />

3<br />

120/240 15-70<br />

120/240 15-125<br />

240 15-100<br />

120/240 15-70<br />

120/240 15-125<br />

240 15-100<br />

QR2, QRH2 2,3 240 100-250<br />

QPH, BQH, BLH<br />

1<br />

2<br />

3<br />

120/240 15-70<br />

120/240 15-125<br />

240 15-100<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-225


Molded Case Circuit Breakers<br />

Series Connected Short Circuit Ratings<br />

Revised on 03/25/17<br />

General<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

240V Breaker Series Ratings (continued)<br />

Series<br />

Rating<br />

kAIR<br />

100000<br />

Main Breaker<br />

Branch Breaker<br />

Type<br />

Max.<br />

Amperes Type<br />

Number<br />

of Poles Voltage Amperes<br />

HED4 100 (1P) ED2, ED4 1 120 15-100<br />

QP, BQ, BL,<br />

1 120/240 15-70<br />

QPH, BQH, BLH,<br />

2 240 15-125<br />

HQP, HBQ, HBL,<br />

3 240 15-100<br />

QAF2, BAF2, QAF, BQAF,<br />

BAF, QAFH2, BAFH2,<br />

HQAF2, HBAF2, QAFH,<br />

BQAFH, BAFH, QFGA2,<br />

1 120 15-20<br />

BFGA2 HQFGA2, HBF-<br />

GA2, QFGAH2, BFGAH2<br />

HED4,<br />

HED6<br />

NGB,<br />

HGB,<br />

LBG<br />

NGB,<br />

HGB,<br />

LBG<br />

HDGA,<br />

HDGB<br />

HQPPH<br />

HQJ2H<br />

125<br />

(2P, 3P)<br />

150<br />

(2P, 3P)<br />

225<br />

(2P)<br />

225<br />

(2P, 3P)<br />

QAF, BAF, QAFH, BAFH 2 120/240 15-20<br />

QEH,BLEH, QE, BE,<br />

QPHF,BQHF, BLHF, QPF,<br />

BLF, BQF, BLE, QPF2, 1 120 15-30<br />

BLF2, QPHF2, BLHF2,<br />

HQPF2, HBLF2<br />

QEH, BLEH, QPHF, QE,<br />

BLHF,QPF,BLF, BLE<br />

2 120/240 15-60<br />

ED2 1,2,3 120/240 15-100<br />

ED4 1 120 15-100<br />

ED4, ED6 2,3 240 15-125<br />

QT 1,2 120/240 15-40<br />

QAF2, QAFH2, QAF,<br />

BQAF, BAF, BAFH2,<br />

HQAF2, HBAF2, QAFH,<br />

BQAFH, BAFH, QFGA2,<br />

1 120 15-20<br />

BFGA2 HQFGA2, HBF-<br />

GA2, QFGAH2, BFGAH2<br />

QAF, BAF, QAFH, BAFH 2 120/240 15-20<br />

QPF,BQF,BLF, QPHF,<br />

BQHF, BLHF, QPF2, BLF2,<br />

QPHF2, BLHF2, HQPF2,<br />

1 120 15-30<br />

HBLF2<br />

QPF, BLF 2 120/240 15-60<br />

QP, BQ, BL, QPH, BQH,<br />

BLH, HQP, HBQ,HBL<br />

1<br />

2<br />

3<br />

120 15-70<br />

120/240 15-125<br />

240 15-100<br />

ED4, ED6 1 240 15-100<br />

ED4, ED6 2,3 240 15-125<br />

NDGA, NDGB 2,3 240 50-150<br />

QP, BQ, BL, QPH, BQH, 1 120/240 15-70<br />

BLH, HQP, HBQ, HBL 2 120/240 15-125<br />

HQPP, QPPH, QPP 2 120/240 125-225<br />

QAF2, BAF2, QAF, BQAF,<br />

BAF, QAFH2, BAFH2,<br />

HQAF2, HBAF2, QAFH,<br />

BQAFH, BAFH, QFGA2,<br />

1 120 15-20<br />

BFGA2 HQFGA2, HBF-<br />

GA2, QFGAH2, BFGAH2<br />

QAF, BAF, QAFH, BAFH 2 120/240 15-20<br />

QEH, BLEH, QE, BE,<br />

QPHF, BQHF, BLHF, QPF,<br />

BQF, BLF, BLE, QPF2, 1 120 15-30<br />

BLF2, QPFH2, BLHF2,<br />

HQPF2, HBLF2<br />

QE, QEH, BLEH,<br />

QPHF,BLHF,QPF,BLF,BLE<br />

2 120/240 15-60<br />

QR2, QRH2, HQR2 2 120/240 100-225<br />

QT 1,2 120/240 15-40<br />

QP, BP, QL 1 120/240 15-25<br />

35-70<br />

2 120/240 15-25<br />

35-125<br />

3 240 15-100<br />

QR2, QRH2, HQR2 2,3 240 100-225<br />

QPH, BQH, BLH, HQP,<br />

HBQ ,HBL<br />

QAF2, BAF2, QAF, BQAF,<br />

BAF, QAFH2, BAFH2,<br />

HQAF2, HBAF2, QAFH,<br />

BQAFH, BAFH, QFGA2,<br />

BFGA2 HQFGA2, HBF-<br />

GA2, QFGAH2, BFGAH2<br />

1<br />

2<br />

3<br />

120/240<br />

120/240<br />

240<br />

15-70<br />

15-125<br />

15-100<br />

1 120 15-20<br />

QAF, BAF, QAFH, QAFH 2 120/240 15-20<br />

QEH, BLEH, QE, BE,<br />

QPHF, BQHF, BLHF, QPF,<br />

BQF, BLF, BLE, QPF2, 1 120 15-30<br />

BLF2, HQPF2, HBLF2,<br />

QPHF2, BLHF2<br />

QEH, BLEH, QPHF, BLE,<br />

BLHF, QE, QPF, BLF<br />

2 120/240 15-60<br />

QT 1 120/240 15-50<br />

240V Breaker Series Ratings (continued)<br />

Series<br />

Rating<br />

kAIR<br />

100000<br />

(cont.)<br />

Main Breaker<br />

Branch Breaker<br />

Type<br />

Max.<br />

Amperes Type<br />

QP, BQ, BL,<br />

QPH, BQH, BLH,<br />

HQP, HBQ, HBL<br />

QAF2, BAF2, QAF, BQAF,<br />

BAF, QAFH2, BAFH2,<br />

HQAF2, HBAF2, QAFH,<br />

BQAFH, BAFH, QFGA2,<br />

BFGA2 HQFGA2, HBF-<br />

GA2, QFGAH2, BFGAH2<br />

HFD6,<br />

HFXD6<br />

HFGA,<br />

HFGB<br />

HQR2H<br />

HJD6-A,<br />

HJXD6-A<br />

250<br />

(2P, 3P)<br />

400<br />

(2P, 3P)<br />

Number<br />

of Poles Voltage Amperes<br />

1<br />

2<br />

3<br />

120/240 15-70<br />

120/240 15-125<br />

240 15-100<br />

1 120 15-20<br />

QAF, BAF, QAFH, BAFH 2 120/240 15-20<br />

QE, BE, BLE, QPHF,<br />

BQHF, BLHF, QPF, BQF,<br />

BLF, QEH, BLEH, QPF2, 1 120 15-30<br />

BLF2, HQPF2, HBLF2,<br />

QPHF2, BLHF2<br />

QPF, BLF, BLE, BLEH,<br />

QPHF, BLHF, QEH, QE<br />

2 120/240 15-60<br />

ED4 1 120 15-100<br />

ED4, ED6 2,3 240 15-125<br />

FD6-A, FXD6-A 2,3 240 70-250<br />

QJ2, QJH2, QJ2H 2,3 240 60-225<br />

HQPP, QPPH, QPP 2 120/240 125-225<br />

QR2, QRH2, HQR2 2,3 240 100-250<br />

QT 1,2 120/240 15-40<br />

NDGA, NDGB 2, 3 240 50-150<br />

NFGA, NFGB 2, 3 240 70-250<br />

ED4, ED6 1 240 15-100<br />

ED4, ED6 2,3 240 15-125<br />

NFGA, NFGB 2, 3 240 70-250<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, HQAF2, HBAF2,<br />

QFGA2, BFGA2 HQFGA2, 1 120 15-20<br />

HBFGA2, QFGAH2,<br />

BFGAH2<br />

QPF2, BLF2, HQPF2,<br />

HBLF2, QPHF2, BLHF2<br />

1 120 15-30<br />

QR2, QRH2, HQR2 2,3 240 100-250<br />

FD6, FXD6 2, 3 240 70-250<br />

FD6-A, FXD6-A 2, 3 240 70-250<br />

QP, BQ, BL<br />

1<br />

2<br />

3<br />

120/240 15-70<br />

120/240 15-125<br />

240 15-100<br />

QT 1,2 120/240 15-50<br />

QFGA2, BFGA2, QAF2,<br />

BAF2, QAF, BAF<br />

1 120 15-20<br />

QAF, BAF 2 120/240 15-20<br />

QPF2, BLF2, QPF, BQF,<br />

BLF, QE, BLE, BE<br />

1 120 15-30<br />

QPF, BLF, QE, BLE 2 120/240 15-60<br />

QPH, BQH, BLH<br />

1<br />

2<br />

120/240 15-70<br />

120/240 15-125<br />

3 240 15-100<br />

QFGAH2, BFGAH2,<br />

QAFH2, BAFH2, HQFGA2,<br />

1<br />

HBFGA2, HQAF2, HBAF2,<br />

120 15-20<br />

QAFH, BAFH<br />

QAFH, BAFH 2 120/240 15-20<br />

QPHF, BLHF, QPHF2,<br />

BLHF2, QEH, BLEH, 1 120 15-30<br />

HQPF2, HBLF2<br />

QEH, BLEH, QPHF, BLHF 2 120/240 15-60<br />

HQP, HBQ, HBL<br />

1<br />

2<br />

120/240 15-70<br />

120/240 15-125<br />

3 240 15-100<br />

QS, QSH, QSHH, HQS 2 120/240 100-225<br />

QR2, QRH2, HQR2 2,3 240 100-250<br />

ED4 1 120 15-100<br />

ED4, ED6 2, 3 240 15-125<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, HQAF2, HBAF2,<br />

QFGA2, BFGA2 HQFGA2, 1 120 15-20<br />

HBFGA2, QFGAH2,<br />

BFGAH2<br />

QPF2, BLF2, HQPF2,<br />

HBLF2, QPHF2, BLHF2<br />

1 120 15-30<br />

QR2, QRH2, HQR2 2,3 240 100-250<br />

FD6-A, FXD6-A 2, 3 240 70-250<br />

JD6-A, JXD6-A<br />

JXD2-A, SJD6-A<br />

2, 3 240 200-400<br />

NDGA, NDGB 2, 3 240 50-150<br />

NFGA, NFGB 2, 3 240 70-250<br />

NJGA, NJJA 2, 3 240 200-400<br />

7-226<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Molded Case Circuit Breakers<br />

Series Connected Short Circuit Ratings<br />

240V Breaker Series Ratings (continued)<br />

240V Breaker Series Ratings (continued)<br />

Revised on 02/06/18<br />

General<br />

Series<br />

Rating<br />

kAIR<br />

100000<br />

(cont.)<br />

Main Breaker<br />

Branch Breaker<br />

Type<br />

Max.<br />

Amperes Type<br />

HJGA<br />

SHJD6,<br />

SHJD6-A,<br />

SHJD6-B<br />

HLD6-A,<br />

HLXD6-A<br />

HLGA,<br />

HLGB<br />

SHLD6,<br />

SHLD6-A,<br />

SHLD6-B<br />

400<br />

(2P, 3P)<br />

400 (3P)<br />

600<br />

(2P, 3P)<br />

600<br />

(3P)<br />

Number<br />

of Poles Voltage Amperes<br />

ED4, ED6 1 240 15-100<br />

ED4, ED6 2,3 240 15-125<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, HQAF2, HBAF2,<br />

QFGA2, BFGA2 HQFGA2, 1 120 15-20<br />

HBFGA2, QFGAH2,<br />

BFGAH2<br />

QPF2, BLF2, HQPF2,<br />

HBLF2, QPHF2, BLHF2<br />

1 120 15-30<br />

NFGA, NFGB 2, 3 240 70-250<br />

FD6, FXD6 2, 3 240 70-250<br />

FD6-A, FXD6-A 2, 3 240 70-250<br />

QR2, QRH2, HQR2 2,3 240 100-250<br />

NJGA, NJJA 2, 3 240 200-400<br />

JD6, JXD6 2, 3 240 200-400<br />

JD6-A, JXD6-A 2, 3 240 200-400<br />

ED4 1 120 15-100<br />

ED4, ED6 2, 3 240 15-125<br />

FD6-A, FXD6-A 2, 3 240 70-250<br />

JD6-A, JXD6-A<br />

JXD2-A, SJD6-A, SJD6-B<br />

2, 3 240 200-400<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, HQAF2, HBAF2,<br />

QFGA2, BFGA2 HQFGA2, 1 120 15-20<br />

HBFGA2, QFGAH2,<br />

BFGAH2<br />

QPF2, BLF2, HQPF2,<br />

HBLF2, QPHF2, BLHF2<br />

1 120 15-30<br />

QR2, QRH2, HQR2 2,3 240 100-250<br />

NDGA, NDGB 2, 3 240 50-150<br />

NFGA, NFGB 2, 3 240 70-250<br />

NJGA, NJJA 2, 3 240 200-400<br />

ED4 1 120 15-100<br />

ED4, ED6 2,3 240 15-125<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, HQAF2, HBAF2,<br />

QFGA2, BFGA2 HQFGA2, 1 120 15-20<br />

HBFGA2, QFGAH2,<br />

BFGAH2<br />

QPF2, BLF2, HQPF2,<br />

HBLF2, QPHF2, BLHF2<br />

1 120 15-30<br />

FD6-A, FXD6-A 2,3 240 70-250<br />

JD6-A, JXD6-A, JXD2-A,<br />

SJD6-A, SJD6-B<br />

2,3 240 200-400<br />

LD6-A 2,3 240 200-600<br />

LXD6-A 2,3 240 450-600<br />

SLD6-A, SLD6-B 3 240 300-600<br />

QR2, QRH2, HQR2 2,3 240 100-250<br />

NDGA, NDGB 2, 3 240 50-150<br />

NFGA, NFGB 2, 3 240 70-250<br />

NJGA, NJJA 2, 3 240 200-400<br />

NLGA, NLGB 2, 3 240 400-600<br />

ED4, ED6 1 240 15-100<br />

ED4, ED6 2,3 240 15-125<br />

NFGA, NFGB 2, 3 240 70-250<br />

FD6, FXD6 2, 3 240 70-250<br />

FD6-A, FXD6-A 2, 3 240 70-250<br />

NJGA, NJJA 2, 3 240 200-400<br />

JD6, JXD6 2, 3 240 200-400<br />

JD6-A, JXD6-A 2, 3 240 200-400<br />

NLGA, NLGB 2, 3 240 400-600<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, HQAF2, HBAF2,<br />

QFGA2, BFGA2 HQFGA2, 1 120 15-20<br />

HBFGA2, QFGAH2,<br />

BFGAH2<br />

QPF2, BLF2, HQPF2,<br />

HBLF2, QPHF2, BLHF2<br />

1 120 15-30<br />

QR2, QRH2, HQR2 2,3 240 100-250<br />

LD6, LD6-A 2, 3 240 200-600<br />

LXD6, LXD6-A 2, 3 240 450-600<br />

ED4 1 120 15-100<br />

ED4, ED6 2,3 240 15-125<br />

FD6-A, FXD6-A 2,3 240 70-250<br />

JD6-A, JXD6-A, JXD2-A,<br />

SJD6-A, SJD6-B<br />

2,3 240 200-400<br />

LD6-A 2,3 240 200-600<br />

LXD6-A 2,3 240 450-600<br />

SLD6-A, SLD6-B 3 240 300-600<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, HQAF2, HBAF2,<br />

QFGA2, BFGA2 HQFGA2, 1 120 15-20<br />

HBFGA2, QFGAH2,<br />

BFGAH2<br />

QPF2, BLF2, HQPF2,<br />

HBLF2, QPHF2, BLHF2<br />

1 120 15-30<br />

Series<br />

Rating<br />

kAIR<br />

100000<br />

(cont.)<br />

Main Breaker<br />

Branch Breaker<br />

Type<br />

Max.<br />

Amperes Type<br />

SHLD6,<br />

SHLD6-A<br />

SHLD6-B<br />

(cont.)<br />

HMG<br />

HMD6,<br />

HMXD6<br />

SHMD6,<br />

SHMD6-B<br />

HNG<br />

600<br />

(3P)<br />

(cont.)<br />

800<br />

(2P, 3P)<br />

800<br />

(3P)<br />

1200<br />

(2P, 3P)<br />

Number<br />

of Poles Voltage Amperes<br />

QR2, QRH2, HQR2 2,3 240 100-250<br />

NDGA, NDGB 2, 3 240 50-150<br />

NFGA, NFGB 2, 3 240 70-250<br />

NJGA, NJJA 2, 3 240 200-400<br />

NLGA, NLGB 2, 3 240 400-600<br />

ED4, ED6 1 240 15-100<br />

ED4, ED6 2,3 240 15-125<br />

NFGA, NFGB 2, 3 240 70-250<br />

FD6, FXD6 2, 3 240 70-250<br />

FD6-A, FXD6-A 2, 3 240 70-250<br />

NJGA, NJJA 2, 3 240 200-400<br />

JD6, JXD6 2, 3 240 200-400<br />

JD6-A, JXD6-A 2, 3 240 200-400<br />

NLGA, NLGB 2, 3 240 400-600<br />

LD6, LD6-A 2, 3 240 200-600<br />

LXD6, LXD6-A 2, 3 240 450-600<br />

NMG 2, 3 240 600-800<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, HQAF2, HBAF2,<br />

QFGA2, BFGA2 HQFGA2, 1 120 15-20<br />

HBFGA2, QFGAH2,<br />

BFGAH2<br />

QPF2, BLF2, HQPF2,<br />

HBLF2, QPHF2, BLHF2<br />

1 120 15-30<br />

QR2, QRH2, HQR2 2,3 240 100-250<br />

LMD6, LMXD6 2, 3 240 600-800<br />

MD6, MXD6 2, 3 240 400-800<br />

NDGA, NDGB 2, 3 240 50-150<br />

NFGA, NFGB 2, 3 240 70-250<br />

NJGA, NJJA 2, 3 240 200-400<br />

NLGA, NLGB 2, 3 240 400-600<br />

NMG 2, 3 240 600-800<br />

ED4 1 120 15-100<br />

ED4, ED6 2,3 240 15-125<br />

FD6-A, FXD6-A 2,3 240 70-250<br />

JD6-A, JXD6-A,<br />

JXD2-A, SJD6-A<br />

2,3 240 200-400<br />

LD6-A 2,3 240 200-600<br />

LXD6-A 2,3 240 450-600<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, HQAF2, HBAF2,<br />

QFGA2, BFGA2 HQFGA2,<br />

HBFGA2, QFGAH2,<br />

BFGAH2<br />

1 120 15-20<br />

QPF2, BLF2, HQPF2,<br />

HBLF2, QPHF2, BLHF2<br />

1 120 15-30<br />

QR2, QRH2, HQR2 2,3 240 100-250<br />

SLD6-A, SLD6-B 3 240 300-600<br />

MD6, MXD6 2,3 240 500-800<br />

SMD6, SMD6-B 3 240 600-800<br />

NDGA, NDGB 2, 3 240 50-150<br />

NFGA, NFGB 2, 3 240 70-250<br />

NJGA, NJJA 2, 3 240 200-400<br />

NLGA, NLGB 2, 3 240 400-600<br />

NMG 2, 3 240 600-800<br />

ED4 1 120 15-100<br />

ED4, ED6 2,3 240 15-125<br />

FD6-A, FXD6-A 2,3 240 70-250<br />

JD6-A, JXD6-A,<br />

JXD2-A<br />

2,3 240 200-400<br />

SJD6-A, SJD6-B 2,3 240 200-400<br />

LD6-A 2,3 240 200-600<br />

LXD6-A 2,3 240 450-600<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, HQAF2, HBAF2,<br />

QFGA2, BFGA2 HQFGA2, 1 120 15-20<br />

HBFGA2, QFGAH2,<br />

BFGAH2<br />

QPF2, BLF2, HQPF2,<br />

HBLF2, QPHF2, BLHF2<br />

1 120 15-30<br />

QR2, QRH2, HQR2 2,3 240 100-250<br />

SLD6-A, SLD6-B 3 240 300-600<br />

MD6, MXD6, SMD6,<br />

SMD6-B<br />

2,3 240 500-800<br />

ED4, ED6 1 240 15-100<br />

ED4, ED6 2,3 240 15-125<br />

NFGA, NFGB 2, 3 240 70-250<br />

FD6, FXD6 2, 3 240 70-250<br />

FD6-A, FXD6-A 2, 3 240 70-250<br />

NJGA, NJJA 2, 3 240 200-400<br />

JD6, JXD6 2, 3 240 200-400<br />

JD6-A, JXD6-A 2, 3 240 200-400<br />

NLGA, NLGB 2, 3 240 400-600<br />

LD6, LD6-A 2, 3 240 200-600<br />

LXD6, LXD6-A 2, 3 240 450-600<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-227


Molded Case Circuit Breakers<br />

Series Connected Short Circuit Ratings<br />

240V Breaker Series Ratings (continued)<br />

240V Breaker Series Ratings (continued)<br />

Revised on 05/31/19<br />

General<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Series<br />

Rating<br />

kAIR<br />

100000<br />

(cont.)<br />

Main Breaker<br />

Branch Breaker<br />

Type<br />

Max.<br />

Amperes Type<br />

HNG<br />

(cont.)<br />

HND6,<br />

HNXD6<br />

SHND6,<br />

SHND6-B<br />

HPG<br />

1200<br />

(2P, 3P)<br />

1200<br />

(3P)<br />

1600<br />

(2P, 3P)<br />

Number<br />

of Poles Voltage Amperes<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, HQAF2, HBAF2,<br />

QFGA2, BFGA2 HQFGA2, 1 120 15-20<br />

HBFGA2, QFGAH2,<br />

BFGAH2<br />

QPF2, BLF2, HQPF2,<br />

HBLF2, QPHF2, BLHF2<br />

1 120 15-30<br />

QR2, QRH2, HQR2 2,3 240 100-250<br />

NMG 2, 3 240 600-800<br />

LMD6, LMXD6 2, 3 240 600-800<br />

NNG 2, 3 240 800-1200<br />

ND6, NXD6 2,3 240 600-1200<br />

ED4 1 240 15-100<br />

ED4, ED6 2,3 240 15-125<br />

FD6-A, FXD6-A 2,3 240 70-250<br />

JD6-A, JXD6-A,<br />

JXD2-A, SJD6-A<br />

2,3 240 200-400<br />

LD6-A 2,3 240 200-600<br />

LXD6-A 2,3 240 450-600<br />

SLD6-A, SLD6-B 3 240 300-600<br />

MD6, MXD6,<br />

SMD6<br />

2,3 240 500-800<br />

ND6, NXD6,<br />

SND6, SND6-B<br />

2,3 240 500-1200<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, HQAF2, HBAF2,<br />

QFGA2, BFGA2 HQFGA2, 1 120 15-20<br />

HBFGA2, QFGAH2,<br />

BFGAH2<br />

QPF2, BLF2, HQPF2,<br />

HBLF2, QPHF2, BLHF2<br />

1 120 15-30<br />

QR2, QRH2, HQR2 2,3 240 100-250<br />

NDGA, NDGB 2, 3 240 50-150<br />

NFGA, NFGB 2, 3 240 70-250<br />

NJGA, NJJA 2, 3 240 200-400<br />

NLGA, NLGB 2, 3 240 400-600<br />

NMG 2, 3 240 600-800<br />

NNG 2, 3 240 800-1200<br />

ED4 1 240 15-100<br />

ED4, ED6 2,3 240 15-125<br />

FD6-A, FXD6-A 2,3 240 70-250<br />

JD6-A, JXD6-A,<br />

JXD2-A, SJD6-A<br />

2,3 240 200-400<br />

LD6-A 2,3 240 200-600<br />

LXD6-A 2,3 240 450-600<br />

SLD6-A, SLD6-B 3 240 300-600<br />

MD6, MXD6,<br />

SMD6, SMD6-B<br />

2,3 240 500-800<br />

ND6, NXD6,<br />

SND6, SND6-B<br />

2,3 240 500-1200<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, HQAF2, HBAF2,<br />

QFGA2, BFGA2 HQFGA2, 1 120 15-20<br />

HBFGA2, QFGAH2,<br />

BFGAH2<br />

QPF2, BLF2, HQPF2,<br />

HBLF2, QPHF2, BLHF2<br />

1 120 15-30<br />

QR2, QRH2, HQR2 2,3 240 100-250<br />

NDGA, NDGB 2, 3 240 50-150<br />

NFGA, NFGB 2, 3 240 70-250<br />

NJGA, NJJA 2, 3 240 200-400<br />

NLGA, NLGB 2, 3 240 400-600<br />

NMG 2, 3 240 600-800<br />

NNG 2, 3 240 800-1200<br />

ED4, ED6 1 240 15-100<br />

ED4, ED6 2,3 240 15-125<br />

NFGA, NFGB 2, 3 240 70-250<br />

FD6, FXD6 2, 3 240 70-250<br />

FD6-A, FXD6-A 2, 3 240 70-250<br />

NJGA, NJJA 2, 3 240 200-400<br />

JD6, JXD6 2, 3 240 200-400<br />

JD6-A, JXD6-A 2, 3 240 200-400<br />

NLGA, NLGB 2, 3 240 400-600<br />

LD6, LD6-A 2, 3 240 200-600<br />

LXD6, LXD6-A 2, 3 240 450-600<br />

QR2, QRH2, HQR2 2,3 240 100-250<br />

NMG 2, 3 240 600-800<br />

LMD6, LMXD6 2, 3 240 600-800<br />

MD6, MXD6 2, 3 240 400-800<br />

NNG 2, 3 240 800-1200<br />

ND6, NXD6 2, 3 240 600-1200<br />

NPG 2, 3 240 1200-1600<br />

PD6, PXD6 2, 3 240 1200-1600<br />

Series<br />

Rating<br />

kAIR<br />

100000<br />

(cont.)<br />

Main Breaker<br />

Branch Breaker<br />

Type<br />

Max.<br />

Amperes Type<br />

HPD6,<br />

HPXD6,<br />

SHPD6<br />

SHPD6-B<br />

SHPD6,<br />

SHPD6-B<br />

HRD6,<br />

HRXD6<br />

200000 CED6<br />

1600<br />

(3P)<br />

2000<br />

(3P)<br />

125<br />

(2P, 3P)<br />

Number<br />

of Poles Voltage Amperes<br />

ED4 1 240 15-100<br />

ED4, ED6 2,3 240 15-125<br />

JD6-A, JXD6-A<br />

JXD2-A<br />

2,3 240 200-400<br />

SJD6-A, SJD6-B 3 240 200-400<br />

LD6-A 2,3 240 200-600<br />

LXD6-A 2,3 240 450-600<br />

SLD6-A, SLD6-B 3 240 300-600<br />

MD6, MXD6, 2,3 240 500-800<br />

SMD6, SMD6-B 3 240 600-800<br />

ND6, NXD6,<br />

SND6, SND6-B<br />

2,3 240 500-1200<br />

PD6, PXD6 2,3 240 1200-1600<br />

SPD6, SPD6-B 3 240 1400-1600<br />

QR2, QRH2, HQR2 2,3 240 100-250<br />

NDGA, NDGB 2, 3 240 50-150<br />

NFGA, NFGB 2, 3 240 70-250<br />

NJGA, NJJA 2, 3 240 200-400<br />

NLGA, NLGB 2, 3 240 400-600<br />

NMG 2, 3 240 600-800<br />

NNG 2, 3 240 800-1200<br />

NPG 2, 3 240 1200-1600<br />

ED4 1 240 15-100<br />

ED4, ED6 2,3 240 15-125<br />

FD6-A, FXD6-A 2,3 240 70-250<br />

JD6-A, JXD6-A, JXD2-A 2,3 240 200-400<br />

SJD6-A, SJD6-B 3 240 200-400<br />

LD6-A 2,3 240 200-600<br />

LXD6-A 2,3 240 450-600<br />

SLD6-A, SLD6-B 3 240 300-600<br />

MD6, MXD6, 2,3 240 500-800<br />

SMD6, SMD6-B 3 240 500-800<br />

ND6, NXD6 2,3 240 500-1200<br />

SND6, SND6-B 3 240 500-1200<br />

NPG, PD6, PXD6 2,3 240 1200-1600<br />

SPD6, SPD6-B 3 240 1400-1600<br />

NDGA, NDGB 2, 3 240 50-150<br />

NFGA, NFGB 2, 3 240 70-250<br />

NJGA, NJJA 2, 3 240 200-400<br />

NLGA 2, 3 240 400-600<br />

NMG 2, 3 240 600-800<br />

NNG 2, 3 240 800-1200<br />

NPG 2, 3 240 1200-1600<br />

ED4 1 240 15-100<br />

ED4, ED6 2,3 240 15-125<br />

JD6-A, JXD6-A, JXD2-A 2,3 240 200-400<br />

SJD6-A, SJD6-B 3 240 200-400<br />

LD6-A 2,3 240 200-600<br />

LXD6-A 2,3 240 450-600<br />

SLD6-A, SLD6-B 3 240 300-600<br />

MD6,MXD6 2,3 240 500-800<br />

SMD6, SMD6-B 3 240 500-800<br />

ND6, NXD6, 2,3 240 500-1200<br />

SND6, SND6-B 3 240 500-1200<br />

PD6, PXD6 2,3 240 1200-1600<br />

SPD6, SPD6-B 3 240 1200-1600<br />

RD6, RXD6 2,3 240 1600-2000<br />

QR2, QRH2, HQR2 2,3 240 100-250<br />

NDGA, NDGB 2,3 240 50-150<br />

NFGA, NFGB 2,3 240 70-250<br />

NJGA, NJJA 2,3 240 200-400<br />

NLGA, NLGB 2,3 240 400-600<br />

NMG 2,3 240 600-800<br />

NNG 2,3 240 800-1200<br />

NPG 2,3 240 1200-1600<br />

QP, BQ, BL<br />

QPH, BQH, BLH,<br />

HQP, HBQ, HBL<br />

QAF2, BAF2, QAF, BQAF,<br />

BAF, QAFH2, BAFH2,<br />

HQAF2, HBAF2, QAFH,<br />

BQAFH, BAFH, HQFGA2,<br />

HBFGA2, QFGA2, QF-<br />

GAH2, BFGAH2<br />

1<br />

2<br />

3<br />

120/240<br />

120/240<br />

240<br />

15-70<br />

15-125<br />

15-100<br />

1 120 15-20<br />

BAF, QAF, BAFH, QAFH 2 120/240 15-20<br />

QPHF, BQHF, BLHF,QPF,<br />

BQF, BLF, QEH, QE, BE, 1 120 15-30<br />

BLEH, BLE<br />

QEH, BLEH, QAHF, QE,<br />

QPHF, BLHF, QPF, 2 120/240 15-60<br />

BLE, BLF<br />

ED4, HED4 1 120 15-100<br />

ED4, ED6, HED4, HED6 2,3 240 15-125<br />

QT 1,2 120/240 15-40<br />

NGB,HGB,LBG 1,2,3 240 15-125<br />

7-228<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Molded Case Circuit Breakers<br />

Series Connected Short Circuit Ratings<br />

240V Breaker Series Ratings (continued)<br />

240V Breaker Series Ratings (continued)<br />

Revised on 05/31/19<br />

General<br />

Series<br />

Rating<br />

kAIR<br />

200000<br />

(cont.)<br />

Main Breaker<br />

Branch Breaker<br />

Type<br />

Max.<br />

Amperes Type<br />

Number<br />

of Poles Voltage Amperes<br />

NGB,HGB,LBG 1,2,3 240 15-125<br />

LDGA, 150<br />

NDGA, NDGB, HDGA,<br />

LDGB (2P, 3P)<br />

2, 3 240 50-150<br />

HDGB<br />

1 120/240 15-70<br />

QP, BQ, BL, QPH, BQH,<br />

2 120/240 15-125<br />

BLH, HQP, HBQ, HBL<br />

3 240 15-100<br />

QAF2, BAF2, QAF, BQAF,<br />

BAF, QAFH2, BAFH2,<br />

HQAF2, HBAF2, QAFH,<br />

BQAFH, BAFH, HQFGA2,<br />

1 120 15-20<br />

HBFGA2, QFGA2, QF-<br />

GAH2, BFGAH2<br />

BAF, QAF, BAFH, QAFH 2 120/240 15-20<br />

QPHF, BQHF, BLHF, QE,<br />

BE, BLE, QPF, BQF, BLF, 1 120 15-30<br />

QEH, BLEH, QAF, BAF<br />

QPHF, BLHF, QE, BLE,<br />

CFD6<br />

QPF, BLF, QEH, BLEH, 2 120/240 15-60<br />

QAF, BAF<br />

LFGA,<br />

LFGB<br />

CJD6-A<br />

LJGA<br />

HHJD6,<br />

HHJXD6<br />

HHLD6,<br />

HHLXD6<br />

CLD6-A<br />

250<br />

(2P, 3P)<br />

400<br />

(2P, 3P)<br />

600<br />

(2P, 3P)<br />

ED2 1,2,3 120/240 15-100<br />

HED4, ED4 1 120 15-100<br />

ED4, ED6,<br />

HED4, HED6<br />

2,3 240 15-125<br />

FD6-A, FXD6-A<br />

HFD6, HFXD6<br />

2,3 240 70-250<br />

QJ2H, QJH2, QJ2 2,3 240 60-225<br />

QPPH, QPP 2 120/240 125-225<br />

QT 1,2 120/240 15-40<br />

NGB,HGB,LBG 1,2,3 240 15-125<br />

NDGA, NDGB, HDGA,<br />

HDGB<br />

2, 3 240 50-150<br />

NFGA, NFGB, HFGA,<br />

HFGB<br />

2, 3 240 70-250<br />

NGB,HGB,LBG 1,2,3 240 15-125<br />

NDGA, NDGB, HDGA,<br />

HDGB<br />

2, 3 240 50-150<br />

NFGA, NFGB, HFGA,<br />

HFGB<br />

240 70-250<br />

HFD6, HFXD6 240 70-250<br />

QPH, BQH, BLH,<br />

2 120/240 100-125<br />

HQP, HBQ, HBL<br />

3 240 100<br />

ED4, ED6 2,3 240 15-125<br />

FD6-A, FXD6-A<br />

HFD6, HFXD6<br />

2,3 240 70-250<br />

JXD2-A, JD6-A,<br />

JXD6-A, HJD6-A, 2,3 240 200-400<br />

HJXD6-A<br />

QT 1,2 120/240 15-30<br />

NGB,HGB,LBG 1,2,3 240 15-125<br />

NDGA, NDGB, HDGA,<br />

HDGB<br />

2, 3 240 50-150<br />

NFGA, NFGB, HFGA,<br />

HFGB<br />

240 70-250<br />

NJGA, HJGA, NJJA 240 200-400<br />

NGB,HGB,LBG 1,2,3 240 15-125<br />

NDGA, NDGB, HDGA,<br />

HDGB<br />

2, 3 240 50-150<br />

NFGA, NFGB, HFGA,<br />

HFGB<br />

240 70-250<br />

HFD6, HFXD6 240 70-250<br />

NJGA, HJGA, NJJA 240 200-400<br />

FD6-A, FXD6-A<br />

2<br />

HFD6, HFXD6<br />

3<br />

240 70-250<br />

NDGA, NDGB, HDGA,<br />

HDGB<br />

2, 3 240 50-150<br />

NFGA, NFGB, HFGA,<br />

HFGB<br />

240 70-250<br />

NJGA, HJGA, NJJA 240 200-400<br />

FD6-A, FXD6-A<br />

HFD6, HFXD6<br />

2, 3 240 70-250<br />

NDGA, NDGB, HDGA,<br />

HDGB<br />

2, 3 240 50-150<br />

NFGA, NFGB, HFGA,<br />

HFGB<br />

240 70-250<br />

NJGA, HJGA, NJJA 240 200-400<br />

NLGA, HLGA, NLGB,<br />

HLGB<br />

240 400-600<br />

QPH, BQH, BLH<br />

2 120/240 100-125<br />

HQP, HBQ, HBL<br />

3 240 100<br />

ED4, ED6 2,3 240 15-125<br />

FD6-A, FXD6-A HFD6,<br />

HFXD6<br />

2,3 240 70-250<br />

JXD2-A, JD6-A, JXD6-A,<br />

HJD6-A, HJXD6-A<br />

2,3 240 200-400<br />

LD6-A, HLD6-A 2,3 240 200-600<br />

Series<br />

Rating<br />

kAIR<br />

200000<br />

(cont.)<br />

Main Breaker<br />

Branch Breaker<br />

Type<br />

Max.<br />

Amperes Type<br />

CLD6-A<br />

(cont.)<br />

LLGA,<br />

LLGB<br />

CMD6<br />

LMG<br />

SCMD6,<br />

SCMD6-A<br />

SCMD6-B<br />

CND6-A<br />

600<br />

(2P, 3P<br />

800<br />

(2P, 3P<br />

800 (3P)<br />

1200<br />

(2P, 3P)<br />

Number<br />

of Poles Voltage Amperes<br />

LXD6-A, HJXD6-A 2,3 240 450-600<br />

QT 1,2 120/240 15-30<br />

NGB,HGB,LBG 1,2,3 240 15-125<br />

NDGA, NDGB, HDGA,<br />

HDGB<br />

2 - 3 240 50-150<br />

NFGA, NFGB, HFGA,<br />

HFGB<br />

240 70-250<br />

NJGA, HJGA, NJJA 240 200-400<br />

NLGA, HLGA, NLGB,<br />

HLGB<br />

240 400-600<br />

NGB,HGB,LBG 1,2,3 240 15-125<br />

NDGA, NDGB, HDGA,<br />

HDGB<br />

2, 3 240 50-150<br />

NFGA, NFGB, HFGA,<br />

HFGB<br />

240 70-250<br />

HFD6, HFXD6 240 70-250<br />

NJGA, HJGA, NJJA 240 200-400<br />

NLGA, HLGA, NLGB,<br />

HLGB<br />

240 400-600<br />

ED4 1 240 15<br />

ED4, ED6,<br />

HED4, HED6<br />

2,3 240 15-125<br />

FD6-A, FXD6-A,<br />

HFD6, HFXD6<br />

2,3 240 70-250<br />

JXD2-A, JD6-A,<br />

JXD6-A, HJD6-A<br />

2,3 240 200-400<br />

HJXD6-A<br />

LD6-A, HLD6-A 2,3 240 200-600<br />

LXD6-A, HLXD6-A 2,3 240 450-600<br />

MD6, MXD6,<br />

HMD6, HMXD6<br />

2,3 240 500-800<br />

NDGA, NDGB, HDGA,<br />

HDGB<br />

2,3 240 50-150<br />

NFGA, NFGB, HFGA,<br />

HFGB<br />

2,3 240 70-250<br />

NJGA, HJGA, NJJA 2,3 240 200-400<br />

NLGA, HLGA, NLGB,<br />

HLGB<br />

2,3 240 400-600<br />

NMG, HMG 2,3 240 600-800<br />

HFD6, HFXD6 2,3 240 70-250<br />

MD6, MXD6 2,3 240 400-800<br />

HMD6, HMXD6 2,3 240 400-800<br />

NDGA, NDGB, HDGA,<br />

HDGB<br />

2,3 240 50-150<br />

NFGA, NFGB, HFGA,<br />

HFGB<br />

2,3 240 70-250<br />

NJGA, HJGA, NJJA 2,3 240 200-400<br />

NLGA, HLGA, NLGB,<br />

HLGB<br />

2,3 240 400-600<br />

NMG, HMG 2,3 240 600-800<br />

MD6, MXD6,<br />

HMD6, HMXD6<br />

2,3 240 500-800<br />

NDGA, NDGB, HDGA,<br />

HDGB<br />

2,3 240 50-150<br />

NFGA, NFGB, HFGA,<br />

HFGB<br />

2,3 240 70-250<br />

NJGA, HJGA, NJJA 2,3 240 200-400<br />

NLGA, HLGA, NLGB,<br />

HLGB<br />

2,3 240 400-600<br />

NMG, HMG 2,3 240 600-800<br />

ED4, ED6 1 240 15<br />

ED4, ED6,<br />

HED4, HED6<br />

2,3 240 15-125<br />

FD6-A, FXD6-A,<br />

HFD6, HFXD6<br />

2,3 240 70-250<br />

JXD2-A, JD6-A,<br />

JXD6-A, HJD6-A, 2,3 240 200-400<br />

HJXD6-A<br />

LD6-A, HLD6-A 2,3 240 200-600<br />

LXD6-A, HLXD6-A 2,3 240 450-600<br />

MD6, MXD6,<br />

HMD6, HMXD6<br />

2,3 240 500-800<br />

ND6, NXD6, SHND6,<br />

HND6,HNXD6<br />

2,3 240 500-1200<br />

NDGA, NDGB, HDGA,<br />

HDGB<br />

2,3 240 50-150<br />

NFGA, NFGB, HFGA,<br />

HFGB<br />

2,3 240 70-250<br />

NJGA, HJGA, NJJA 2,3 240 200-400<br />

NLGA, HLGA, NLGB,<br />

HLGB<br />

2,3 240 400-600<br />

NMG, HMG 2,3 240 600-800<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-229


Molded Case Circuit Breakers<br />

Series Connected Short Circuit Ratings<br />

Revised on 05/31/19<br />

General<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

240V Breaker Series Ratings (continued)<br />

Series<br />

Rating<br />

kAIR<br />

200000<br />

(cont.)<br />

Main Breaker<br />

Branch Breaker<br />

Type<br />

Max.<br />

Amperes Type<br />

Number<br />

of Poles Voltage Amperes<br />

HFD6, HFXD6 2,3 240 70-250<br />

MD6, MXD6<br />

HMD6, HMXD6<br />

2,3 240 400-800<br />

ND6,NXD6,HND6,HNXD6 2,3 240 600-1200<br />

LNG<br />

NDGA, NDGB, HDGA,<br />

1200 HDGB<br />

2,3 240 50-150<br />

(2P, 3P) NFGA, NFGB, HFGA,<br />

HFGB<br />

2,3 240 70-250<br />

NJGA, HJGA, NJJA 2,3 240 200-400<br />

NLGA, HLGA, NLGB,<br />

HLGB<br />

2,3 240 400-600<br />

NMG, HMG 2,3 240 600-800<br />

MD6, HMD6,<br />

HMXD6, MXD6, MXD6<br />

2,3 240 400-800<br />

SHMD6, SMD6,<br />

2,3 240 400-800<br />

SHMD6-B, SMD6-B<br />

SCND6-A, 1200<br />

NMG, HMG 2,3 240 600-800<br />

SCND6-B (3P)<br />

ND6, HND6, NXD6,<br />

2,3 240 500-1200<br />

HNXD6<br />

SHND6, SND6,<br />

SHND6-B, SND6-B<br />

3 240 500-1200<br />

NDGA, NDGB, HNDGA,<br />

NDGB<br />

2,3 240 50-150<br />

NFGA, NFGB, HFGA,<br />

SCND6-A, 1200 HFGB<br />

2,3 240 70-250<br />

SCND6-B (2P, 3P) NJGA, HJGA, NJJA 2,3 240 200-400<br />

NLGA, HLGA, NLGB,<br />

HLGB<br />

2,3 240 400-600<br />

NMG, HMG 2,3 240 600-800<br />

FD6-A, FXD6-A,<br />

HFD6, HFXD6<br />

2,3 240 70-250<br />

JXD2-A, JD6-A,<br />

JXD6-A, HJD6-A, 2,3 240 200-400<br />

HJXD6-A<br />

LD6-A, HLD6-A 2,3 240 200-600<br />

LXD6-A, HLXD6-A 2,3 240 450-600<br />

MD6, MXD6, HMD6,<br />

2,3 240 500-800<br />

HMXD6<br />

1600<br />

CPD6<br />

ND6, NXD6,<br />

(3P)<br />

2,3 240 500-1200<br />

HND6, HNXD6, SND6<br />

NDGA, NDGB, HDGA,<br />

HDGB<br />

2,3 240 50-150<br />

NFGA, NFGB, HFGA,<br />

HFGB<br />

2,3 240 70-250<br />

NJGA, HJGA, NJJA 2,3 240 200-400<br />

NLGA, HLGA, NLGB,<br />

HLGB<br />

2,3 240 400-600<br />

NMG, HMG 2,3 240 600-800<br />

MD6,MXD6,<br />

HMD6, HMXD6<br />

2,3 240 400-800<br />

ND6,NXD6,<br />

HND6, HNXD6<br />

2,3 240 600-1200<br />

PD6, PXD6, HPD6<br />

HPXD6<br />

2,3 240 1000-1600<br />

NDGA, NDGB, HDGA,<br />

1600<br />

2,3 240 50-150<br />

LPG<br />

HDGB<br />

(2P, 3P)<br />

NFGA, NFGB, HFGA,<br />

2,3 240 70-250<br />

HFGB<br />

HFD6, HFXD6 2,3 240 70-250<br />

NJGA, HJGA, NJJA 2,3 240 200-400<br />

NLGA, HLGA, NLGB,<br />

HLGB<br />

2,3 240 400-600<br />

NMG, HMG 2,3 240 600-800<br />

480V Breaker Series Ratings<br />

Series<br />

Rating<br />

kAIR<br />

Main Breaker<br />

Type<br />

18,000 ED4<br />

ED6<br />

NGB,<br />

HGB,<br />

25,000 LBG<br />

35,000<br />

42,000<br />

50,000<br />

HED6<br />

FD6-A,<br />

FXD6-A<br />

JD6-A,<br />

JXD6-A<br />

HED4<br />

HJD6-A,<br />

HJXD6-A<br />

HFD6,<br />

HFXD6<br />

HJD6-A,<br />

HJXD6-A,<br />

HLD6-A,<br />

HLXD6-A<br />

MD6,<br />

MXD6<br />

SMD6<br />

SMD6-B<br />

ND6,<br />

NXD6<br />

SND6<br />

SND6-B<br />

SPD6,<br />

SPD6-B<br />

Max.<br />

Amperes<br />

125<br />

(2 & 3P)<br />

125<br />

(2P & 3P)<br />

250<br />

(2P & 3P)<br />

400<br />

(2P & 3P)<br />

125<br />

(2P & 3P)<br />

400<br />

(2P & 3P)<br />

250<br />

(2P & 3P)<br />

400<br />

(2P & 3P)<br />

600<br />

(2P & 3P)<br />

800<br />

(2P & 3P)<br />

800<br />

(3P)<br />

1200<br />

(2P & 3P)<br />

1200<br />

(3P)<br />

1600<br />

(3P)<br />

Branch Breaker<br />

Type<br />

Number<br />

of Poles Voltage Amperes<br />

BQD, CQD 1,2,3 277/480 15-100<br />

BQD, CQD 1,2,3 277/480 15-100<br />

1 277 15-100<br />

BQD, CQD<br />

2 277/480 15-100<br />

3 277/480 15-100<br />

BQD, CQD 1,2,3 277/480 15-100<br />

ED4 1 277 15-100<br />

ED4, ED6 2,3 480 15-125<br />

NGB,HGB,LBG<br />

NGB,HGB,LBG<br />

1<br />

2<br />

3<br />

1<br />

2<br />

3<br />

277<br />

277/480<br />

277/480<br />

277<br />

277/480<br />

277/480<br />

15-125<br />

15-125<br />

15-125<br />

15-125<br />

15-125<br />

15-125<br />

BQD, CQD 1,2,3 277/480 15-100<br />

ED4 1 277 15-100<br />

ED4, ED6 2,3 480 15-125<br />

NGB,HGB,LBG<br />

NGB,HGB,LBG<br />

1<br />

2<br />

3<br />

1<br />

2<br />

3<br />

277<br />

277/480<br />

277/480<br />

277<br />

277/480<br />

277/480<br />

15-125<br />

15-125<br />

15-125<br />

15-125<br />

15-125<br />

15-125<br />

HED4 2,3 480 15-50<br />

HED4 2,3 480 15-50<br />

FD6-A, FXD6-A 2,3 480 70-250<br />

JD6-A,JXD6-A 2,3 480 200-400<br />

SJD6-A, SJD6-B 3 480 200-400<br />

LD6-A 2,3 480 200-600<br />

LXD6-A 2,3 480 450-600<br />

SLD6-A, SLD6-B 3 480 400-600<br />

NDGA, NDGB 2,3 480 50-150<br />

NFGA, NFGB 2,3 480 70-250<br />

NJGA 2,3 480 250-400<br />

NLGA, NLGB 2,3 480 400-600<br />

NMG 2,3 480 600-800<br />

JD6-A, JXD6-A 2,3 480 200-400<br />

SJD6-A, SJD6-B 3 480 200-400<br />

LD6-A 2,3 480 200-600<br />

LXD6-A 2,3 480 450-600<br />

SLD6-A, SLD6-B 3 480 400-600<br />

LMD6, LMXD6 2,3 480 600-800<br />

NDGA, NDGB 2,3 480 50-150<br />

NFGA, NFGB 2,3 480 70-250<br />

NJGA 2,3 480 250-400<br />

NLGA, NLGB 2,3 480 400-600<br />

NMG 2,3 480 600-800<br />

FD6-A, FXD6-A 2,3 380 70-250<br />

JD6-A, JXD6-A 2,3 480 200-400<br />

SJD6-A, SJD6-B 3 480 200-400<br />

LD6-A 2,3 480 200-600<br />

LXD6-A 2,3 480 450-600<br />

SLD6-A, SLD6-B 3 480 400-600<br />

NDGA, NDGB 2,3 480 50-150<br />

NFGA, NFGB 2,3 480 70-250<br />

NJGA 2,3 480 250-400<br />

NLGA, NLGB 2,3 480 400-600<br />

NMG, LMD6,<br />

LMXD6<br />

2,3 480 600-800<br />

JD6-A, JXD6-A 2,3 480 200-400<br />

SJD6-A, SJD6-B 3 480 200-400<br />

LD6-A 2,3 480 200-600<br />

LXD6-A 2,3 480 450-600<br />

SLD6-A, SLD6-B 3 480 400-600<br />

LMD6, LMXD6 2,3 480 600-800<br />

NDGA, NDGB 2,3 480 50-150<br />

NFGA, NFGB 2,3 480 70-250<br />

NJGA 2,3 480 250-400<br />

NLGA, NLGB 2,3 480 400-600<br />

NMG 2,3 480 600-800<br />

JD6-A, JXD6-A 2,3 480 200-400<br />

SJD6-A, SJD6-B 3 480 200-400<br />

LD6-A 2,3 480 200-600<br />

LXD6-A 2,3 480 450-600<br />

SLD6-A, SLD6-B 3 480 400-600<br />

7-230<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Molded Case Circuit Breakers<br />

Series Connected Short Circuit Ratings<br />

Revised on 05/31/19<br />

General<br />

480V Breaker Series Ratings (continued)<br />

Series<br />

Rating<br />

kAIR<br />

50,000<br />

(cont.)<br />

65,000<br />

Main Breaker<br />

Type<br />

PD6, PXD6<br />

RD6, RXD6<br />

HDGA,<br />

HDGB<br />

HFD6,<br />

HFXD6<br />

HFGA,<br />

HFGB<br />

HJD6-A,<br />

HJXD6-A<br />

HJGA<br />

HHJD6,<br />

HHJXD6<br />

HLD6-A,<br />

HLXD6-A<br />

HHLD6,<br />

HHLXD6<br />

HLGA,<br />

HLGB<br />

HMD6,<br />

HMXD6<br />

Max.<br />

Amperes<br />

1600<br />

(3P)<br />

18-2000<br />

(3P)<br />

150<br />

(2P & 3P)<br />

250<br />

(2P & 3P)<br />

400<br />

(2P & 3P)<br />

600<br />

(2P & 3P)<br />

800<br />

(2P & 3P)<br />

Branch Breaker<br />

Number<br />

Type<br />

of Poles Voltage Amperes<br />

FD6-A, FXD6-A 2,3 480 70-250<br />

JD6-A, JXD6-A 2,3 480 200-400<br />

SJD6-A 3 480 200-400<br />

LD6-A 2,3 480 200-600<br />

LXD6-A 2,3 480 450-600<br />

SLD6-A, SLD6-B 3 480 400-600<br />

NDGA, NDGB 2,3 480 50-150<br />

NFGA, NFGB 2,3 480 70-250<br />

NJGA 2,3 480 250-400<br />

NLGA, NLGB 2,3 480 400-600<br />

NMG 2,3 480 600-800<br />

NNG 2,3 480 800-1200<br />

NPG 2,3 480 1200-1600<br />

FD6-A, FXD6-A 2,3 480 70-250<br />

JD6-A, JXD6-A 2,3 480 200-400<br />

SJD6-A, SJD6-B 3 480 200-400<br />

LD6-A 2,3 480 200-600<br />

LXD6-A 2,3 480 450-600<br />

SLD6-A, SLD6-B 3 480 400-600<br />

NDGA, NDGB 2,3 480 50-150<br />

NFGA, NFGB 2,3 480 70-250<br />

NJGA 2,3 480 250-400<br />

NLGA, NLGB 2,3 480 400-600<br />

NMG 2,3 480 600-800<br />

NNG 2,3 480 800-1200<br />

NPG 2,3 480 1200-1600<br />

NDGA, NDGB 2,3 480 50-150<br />

BQD, CQD 1,2,3 277/480 15-100<br />

ED4, HED4 1 277 15-100<br />

ED4, ED6, HED4,<br />

HED6<br />

2,3 480 15-125<br />

NDGA, NDGB<br />

480 50-150<br />

2,3<br />

NFGA, NFGB 480 70-250<br />

NDGA, NDGB<br />

480 50-150<br />

2,3<br />

NFGA, NFGB 480 70-250<br />

HED4, ED4 1 277 15-100<br />

FD6-A, FXD6-A 2,3 480 70-250<br />

JD6-A, JXD6-A 2,3 480 200-400<br />

NDGA, NDGB 2,3 480 50-150<br />

NFGA, NFGB 2,3 480 70-250<br />

NJGA 2,3 480 250-400<br />

NDGA, NDGB 2,3 480 50-150<br />

NFGA, NFGB 2,3 480 70-250<br />

NJGA 2,3 480 250-400<br />

NGB,HGB,LBG<br />

NGB,HGB,LBG<br />

1<br />

2<br />

3<br />

1<br />

2<br />

3<br />

277<br />

277/480<br />

277/480<br />

277<br />

277/480<br />

277/480<br />

15-125<br />

15-125<br />

15-125<br />

15-125*<br />

15-125*<br />

15-125*<br />

ED4, HED4 1 277 15-100<br />

FD6-A, FXD6-A 2,3 480 70-250<br />

JD6-A, JXD6-A 2,3 480 200-400<br />

LD6-A 2,3 480 200-600<br />

LXD6-A 2,3 480 450-600<br />

NDGA, NDGB 2,3 480 50-150<br />

NFGA, NFGB 2,3 480 70-250<br />

NJGA 2,3 480 250-400<br />

NLGA, NLGB 2,3 480 400-600<br />

NGB,HGB,LBG<br />

NGB,HGB,LBG<br />

1<br />

2<br />

3<br />

1<br />

2<br />

3<br />

277<br />

277/480<br />

277/480<br />

277<br />

277/480<br />

277/480<br />

15-125<br />

15-125<br />

15-125<br />

15-125*<br />

15-125*<br />

15-125*<br />

NDGA, NDGB 2,3 480 50-150<br />

NFGA, NFGB 2,3 480 70-250<br />

NJGA 2,3 480 250-400<br />

NLGA, NLGB 2,3 480 400-600<br />

FD6-A, FXD6-A 2,3 480 70-250<br />

JD6-A, JXD6-A 2,3 480 200-400<br />

LD6-A 2,3 480 200-600<br />

LXD6-A 2,3 480 450-600<br />

LMD6, LMXD6 2,3 480 600-800<br />

MD6, MXD6 2,3 480 400-800<br />

NDGA, NDGB,<br />

NDGB<br />

2,3 480 50-150<br />

NFGA, NFGB 2,3 480 70-250<br />

NJGA 2,3 480 250-400<br />

NLGA, NLGB 2,3 480 400-600<br />

NMG 2,3 480 600-800<br />

480V Breaker Series Ratings (continued)<br />

Series<br />

Rating<br />

kAIR<br />

65,000<br />

(cont.)<br />

100,000<br />

Main Breaker<br />

Type<br />

HMG<br />

HND6,<br />

HNXD6<br />

HNG<br />

HPD6,<br />

HPXD6<br />

HPG<br />

HRD6,<br />

HRXD6<br />

LDGA,<br />

LDGB<br />

CFD6<br />

LFGA,<br />

LFGB<br />

HHFD6,<br />

HHFXD6<br />

Max.<br />

Amperes<br />

800<br />

(2P & 3P)<br />

(cont.)<br />

1200<br />

(2P & 3P)<br />

1600<br />

(3P)<br />

1600<br />

(2P & 3P)<br />

18-2000<br />

(3P)<br />

150<br />

(2P & 3P)<br />

250<br />

(2P & 3P)<br />

Branch Breaker<br />

Number<br />

Type<br />

of Poles Voltage Amperes<br />

LMD6,LMXD6 2,3 480 600-800<br />

MD6,MXD6 2,3 480 400-800<br />

SMD6, SMD6-B 3 480 500-800<br />

NDGA, NDGB,<br />

NDGB<br />

2,3 480 50-150<br />

NFGA, NFGB 2,3 480 70-250<br />

NJGA 2,3 480 250-400<br />

NLGA, NLGB 2,3 480 400-600<br />

NMG 2,3 480 600-800<br />

FD6-A, FXD6-A 2,3 480 70-250<br />

JD6-A, JXD6-A 2,3 480 200-400<br />

LD6-A 2,3 480 200-600<br />

LXD6-A 2,3 480 450-600<br />

MD6, MXD6 2,3 480 500-800<br />

SMD6, SMD6-B 3 480 500-800<br />

LMD6, LMXD6 2,3 480 600-800<br />

NDGA, NDGB,<br />

NDGB<br />

2,3 480 50-150<br />

NFGA, NFGB 2,3 480 70-250<br />

NJGA 2,3 480 250-400<br />

NLGA, NLGB 2,3 480 400-600<br />

NMG 2,3 480 600-800<br />

NNG 2,3 480 800-1200<br />

LMD6,LMXD6 2,3 480 600-800<br />

MD6, MXD6 2,3 480 400-800<br />

ND6,NXD6 2,3 480 800-1200<br />

NDGA, NDGB,<br />

NDGB<br />

2,3 480 50-150<br />

NFGA, NFGB 2,3 480 70-250<br />

NJGA 2,3 480 250-400<br />

NLGA, NLGB 2,3 480 400-600<br />

NMG 2,3 480 600-800<br />

NNG 2,3 480 800-1200<br />

FD6-A, FXD6-A 2,3 480 70-250<br />

NDGA, NDGB,<br />

NDGB<br />

2,3 480 50-150<br />

NFGA, NFGB 2,3 480 70-250<br />

NJGA 2,3 480 250-400<br />

NLGA, NLGB 2,3 480 400-600<br />

NMG 2,3 480 600-800<br />

NNG 2,3 480 800-1200<br />

NPG 2,3 480 1200-1600<br />

LMD6,LMXD6 2,3 480 600-800<br />

MD6, MXD6 2,3 480 400-800<br />

ND6,NXD6 2,3 480 800-1200<br />

NDGA, NDGB 2,3 480 50-150<br />

NFGA, NFGB 2,3 480 70-250<br />

NJGA 2,3 480 250-400<br />

NLGA, NLGB 2,3 480 400-600<br />

NMG 2,3 480 600-800<br />

NNG 2,3 480 800-1200<br />

NPG 2,3 480 1200-1600<br />

FD6-A, FXD6-A 2,3 480 70-250<br />

JD6-A, JXD6-A 2,3 480 200-400<br />

LD6-A 2,3 480 200-600<br />

LXD6-A 2,3 480 450-600<br />

NDGA, NDGB 2,3 480 50-150<br />

NFGA, NFGB 2,3 480 70-250<br />

NJGA 2,3 480 250-400<br />

NLGA, NLGB 2,3 480 400-600<br />

NMG 2,3 480 600-800<br />

NNG 2,3 480 800-1200<br />

NPG 2,3 480 1200-1600<br />

NGB,HGB,LBG<br />

BQD, CQD<br />

NGB,HGB,LBG<br />

1<br />

2<br />

3<br />

1<br />

2,3<br />

1<br />

2<br />

3<br />

277<br />

277/480<br />

277/480<br />

15-125*<br />

15-125*<br />

15-125*<br />

277/480<br />

277/480<br />

15-100<br />

15-30<br />

277 15-125*<br />

277/480 15-125*<br />

277/480 15-125*<br />

NDGA, NDGB,<br />

HDGA, HDGB<br />

2,3 480 50-150<br />

NFGA, NFGB,<br />

HFGA, HFGB<br />

2,3 480 70-250<br />

HFD6, HFXD6 2, 3 480 70-250<br />

1 277 15-125*<br />

NGB,HGB,LBG 2 277/480 15-125*<br />

3 277/480 15-125*<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-231


Molded Case Circuit Breakers<br />

Series Connected Short Circuit Ratings<br />

Revised on 05/31/19<br />

General<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

480V Breaker Series Ratings (continued)<br />

Series<br />

Rating<br />

kAIR<br />

100,000<br />

(cont.)<br />

Main Breaker<br />

Type<br />

HHJXD6,<br />

HHJD6,<br />

CJD6-A<br />

LJGA<br />

HHLD6,<br />

HHLXD6<br />

LLGA,<br />

LLGB<br />

CMD6<br />

LMG<br />

SCMD-A<br />

SCMD6-B<br />

SCND6-A<br />

SCND6-B<br />

LNG<br />

Max.<br />

Amperes<br />

400<br />

(2P, 3P)<br />

600<br />

(2P, 3P)<br />

800<br />

(3P)<br />

800<br />

(2P, 3P)<br />

Branch Breaker<br />

Number<br />

Type<br />

of Poles Voltage Amperes<br />

ED4, ED6, HED4,<br />

HED6<br />

1 277 15-100<br />

HFD6, HFXD6,<br />

FXD6-A, FD6-A<br />

2,3 480 70-250<br />

NDGA, NDGB,<br />

HDGA, HDGB<br />

2,3 480 50-150<br />

NFGA, NFGB,<br />

HFGA, HFGB<br />

2,3 480 70-250<br />

NJGA, HJGA 2,3 480 200-400<br />

1 277 15-125*<br />

NGB,HGB,LBG 2 277/480 15-125*<br />

3 277/480 15-125*<br />

NDGA, NDGB,<br />

HDGA, HDGB<br />

2,3 480 50-150<br />

NFGA, NFGB,<br />

HFGA, HFGB<br />

2,3 480 70-250<br />

HFD6, HFXD6 2,3 480 70-250<br />

ED4, ED6, HED4,<br />

HED6<br />

1 277 15-100<br />

HFD6, HFXD6,<br />

FXD6-A, FD6-A<br />

2,3 480 70-250<br />

NDGA, NDGB,<br />

HDGA, HDGB<br />

2,3 480 50-150<br />

NFGA, NFGB,<br />

HFGA, HFGB<br />

2,3 480 70-250<br />

NJGA, HJGA 2,3 480 200-400<br />

NDGA, NDGB,<br />

HDGA, HDGB<br />

2,3 480 50-150<br />

NFGA, NFGB,<br />

HFGA, HFGB<br />

2,3 480 70-250<br />

HFD6, HFXD6 2,3 480 70-250<br />

NJGA , HJGA 2,3 480 200-400<br />

FD6-A, FXD6-A<br />

HFD6-A, HFXD6-A<br />

2,3 480 70-250<br />

JD6-A, HJD6-A,<br />

JXD6-A, HJXD6-A<br />

2,3 480 200-400<br />

LD6-A, HLD6-A 2,3 480 200-600<br />

LXD6-A, HLXD6-A 2,3 480 450-600<br />

MD6, MXD6, HMD6,<br />

2,3<br />

HMXD6<br />

480 500-800<br />

NDGA, NDGB,<br />

HDGA, HDGB<br />

2,3 480 50-150<br />

NFGA, NFGB,<br />

HFGA, HFGB<br />

2,3 480 70-250<br />

NJGA, HJGA 2,3 480 200-400<br />

NLGA, HLGA,<br />

NLGB, HLGB<br />

2,3 480 400-600<br />

NDGA, NDGB,<br />

HDGA, HDGB<br />

2,3 480 50-150<br />

NFGA, NFGB,<br />

HFGA, HFGB<br />

2,3 480 70-250<br />

HFD6, HFXD6 2,3 480 70-250<br />

NJGA, HJGA 2,3 480 200-400<br />

NLGA, NLGB,<br />

HLGA, HLGB<br />

2,3 480 400-600<br />

MD6, MXD6, HMD6,<br />

2,3<br />

HMXD6<br />

480 500-800<br />

800 (3P) HFD6, HFXD6 2,3 480 70-250<br />

1200 (3P) HFD6, HFXD6 2,3 480 70-250<br />

NDGA, NDGB,<br />

HDGA, HDGB<br />

2,3 480 50-150<br />

NFGA, NFGB,<br />

HFGA, HFGB<br />

2,3 480 70-250<br />

HFD6, HFXD6 2,3 480 70-250<br />

1200 NJGA, HJGA 2,3 480 200-400<br />

(2P, 3P) NLGA, HLGA,<br />

NLGB, HLGB<br />

2,3 480 400-600<br />

MD6, MXD6, HMD6<br />

HMXD6<br />

2,3 480 400-800<br />

ND6, NXD6, HND6<br />

HNXD6<br />

2,3 480 600-1200<br />

480V Breaker Series Ratings (continued)<br />

Series<br />

Rating<br />

kAIR<br />

100,000<br />

(cont.)<br />

150,000<br />

200,000<br />

Main Breaker<br />

Type<br />

CND6<br />

CPD6<br />

LPG (2,3P)<br />

CJD6-A<br />

CLD6-A<br />

CED6<br />

CFD6<br />

Branch Breaker<br />

Max.<br />

Number<br />

Amperes Type<br />

of Poles Voltage Amperes<br />

FD6-A, FXD6-A 2,3 480 70-250<br />

HFD6-A, HFXD6-A 2,3 480 70-250<br />

JD6-A, HJD6-A<br />

JXD6-A, HJXD6-A<br />

2,3 480 200-400<br />

LD6-A, HLD6-A 2,3 480 200-600<br />

LXD6-A, HLXD6-A 2,3 480 450-600<br />

1200 (3P)<br />

MD6, MXD6<br />

HMD6, HMXD6<br />

2,3 480 500-800<br />

ND6, NXD6<br />

HND6, HNXD6<br />

2,3 480 500-1200<br />

NDGA, NDGB,<br />

HDGA, HDGB<br />

480 50-150<br />

NFGA, NFGB,<br />

HFGA, HFGB 2 - 3<br />

480 70-250<br />

NJGA, HJGA 480 200-400<br />

NLGA, HLGA,<br />

NLGB, HLGB<br />

480 400-600<br />

FD6-A, FXD6-A<br />

HFD6-A, HFXD6-A<br />

2,3 480 70-250<br />

NDGA, NDGB,<br />

HDGA, HDGB<br />

2,3 480 50-150<br />

1600 (3P) NFGA, NFGB,<br />

HFGA, HFGB<br />

2,3 480 70-250<br />

NJGA, HJGA 2,3 480 200-400<br />

NLGA, HLGA,<br />

NLGB, HLGB<br />

2,3 480 400-600<br />

NDGA, NDGB,<br />

HDGA, HDGB<br />

2,3 480 50-150<br />

NFGA, NFGB,<br />

HFGA, HFGB<br />

2,3 480 70-250<br />

HFD6, HFXD6 2,3 480 70-250<br />

NJGA, HJGA 2,3 480 200-400<br />

1600 NLGA, NLGB,<br />

(2P, 3P) HLGA, HLGB<br />

2,3 480 400-600<br />

MD6, MXD6, HMD6,<br />

2,3<br />

HMXD6<br />

480 500-800<br />

ND6, NXD6, HND6<br />

HNXD6<br />

2,3 480 500-1200<br />

PD6,PXD6, HPD6<br />

HPXD6<br />

2,3 480 1200-1600<br />

ED4 1 277 15-100<br />

400 HFD6, HFXD6 2,3 480 70-250<br />

(2P, 3P) JD6-A, HJD6-A,<br />

JXD6-A, HJXD6-A<br />

2,3 480 200-400<br />

ED4 1 277 15-100<br />

HFD6, HFXD6 2,3 480 70-250<br />

600 JD6-A, HJD6-A,<br />

(2P, 3P) JXD6-A, HJXD6-A<br />

2,3 480 200-400<br />

LD6-A, HLD6-A 2,3 480 200-600<br />

LXD6-A, HLXD6-A 2,3 480 450-600<br />

BQD, CQD<br />

1 277 15-100<br />

2,3 277/480 20-30<br />

ED4, HED4 1 277 15-100<br />

125 ED4, ED6, HED4,<br />

(2P, 3P) HED6<br />

2,3 480 15-125<br />

1 277 15-125<br />

NGB,HGB,LBG 2 277/480 15-125<br />

3 277/480 15-125<br />

BQD, CQD<br />

1 277 15-100<br />

2,3 277/480 20-30<br />

250<br />

(2P, 3P)<br />

ED4, ED6 2,3 277 15-50<br />

ED4, HED4 1 480 15-100<br />

HED4, HED6 2,3 480 15-125<br />

FD6-A, FXD6-A,<br />

HFD6, HFXD6<br />

2,3 480 70-250<br />

NGB,HGB,LBG<br />

1<br />

2<br />

3<br />

277<br />

277/480<br />

277/480<br />

15-125<br />

15-125<br />

15-125<br />

7-232<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Molded Case Circuit Breakers<br />

Series Connected Short Circuit Ratings<br />

Revised on 02/06/18<br />

General<br />

240V Fuse Series Ratings<br />

Series<br />

Rating<br />

kAIR<br />

65,000<br />

100,000<br />

Main Fuse<br />

Branch Breaker<br />

Type<br />

Max.<br />

Amperes<br />

Type<br />

Number<br />

of Poles<br />

Max.<br />

Amperes<br />

J, R 15-600 (1,2,3P) QPH, BQH, BLH 1,2,3 15-125<br />

T 15-1200 (1,2,3P) QPH, BQH, BLH 1,2,3 15-125<br />

L<br />

601-6000<br />

(1,2,3P)<br />

QPH, BQH, BLH 1,2,3 15-125<br />

QP, BQ, BL 1,2,3 15-125<br />

HQP, HBQ, HBL,<br />

QPH, BQH, BLH<br />

3 15-100<br />

QPF, BQF, BLF, QHPF,<br />

QE, BE, BLE, QEH, BLEH,<br />

1<br />

15-200 (1,2,3P) BLHF, BQHF, QAF, BAF,<br />

15-30<br />

QAFH, BAFH<br />

T<br />

(300V)<br />

J, R<br />

T<br />

L<br />

QEH, BLEH, QE, QPF,<br />

QPHF, BLHF, BLE, BLF, 2 15-60<br />

QAF, BAF, QAFH, BAFH<br />

QT 1,2 15-50<br />

15-600 (1,2,3P)<br />

QPH, BQH, BLH, HQP,<br />

HBQ, HBL<br />

1,2 15-125<br />

ED4, HED4 1 15-100<br />

ED4, ED6, HED4, HED6 2,3 15-125<br />

QAF2, BAF2, QAFH2,<br />

15-600 (2,3P) BAFH2, QFGA2, BFGA2, 1 15-20<br />

QFGAH2, BFGAH2<br />

QPF2, BLF2, HQPF2,<br />

HBLF2, QPHF2, BLHF2<br />

1 15-30<br />

70-600 (2,3P) FD6-A, FXD6-A 2,3 70-250<br />

100-600 (2,3P) QR2, QRH2, HQR2 2,3 100-250<br />

JD6-A, JXD6-A, JXD2-A,<br />

2,3<br />

200-600 (2,3P) SJD6-A, SJD6-B<br />

200-400<br />

LD6-A 2,3 200-600<br />

300-600 (3P) SLD6-A, SLD6-B 3 300-600<br />

450-600 (2,3P) LXD6-A 2,3 450-600<br />

ED4, HED4 1 15-100<br />

ED4, ED6, HED4, HED6 2,3 15-125<br />

15-1200 (2,3P)<br />

QAF2, BAF2, QAFH2,<br />

BAFH2, HQAF2, HBAF2,<br />

QFGA2, BFGA2, QF-<br />

1 15-20<br />

GAH2, BFGAH2<br />

QPF2, BLF2, HQPF2,<br />

HBLF2, QPHF2, BLHF2<br />

1 15-30<br />

70-1200 (2,3P) FXD6-A, FD6-A 2,3 70-250<br />

100-600 (2,3P) QR2, QRH2, HQR2 2,3 100-250<br />

450-1200 (2,3P) LXD6-A 2,3 450-600<br />

JD6-A, JXD6-A,<br />

2,3 200-400<br />

JXD2-A<br />

200-1200 (2,3P)<br />

SJD6-A, SJD6-B 3 200-400<br />

LD6-A 2,3 200-600<br />

300-1200 (3P) SLD6-A, SLD6-B 3 300-600<br />

601-6000<br />

(2,3P)<br />

ED4, HED4 1 15-100<br />

ED4, ED6, HED4, HED6 2,3<br />

FD6-A, FXD6-A 2,3 70-250<br />

JD6-A, JXD6-A, JXD2-A 2,3 200-400<br />

SJD6-A, SJD6-B 3 200-400<br />

LD6-A 2,3 200-600<br />

LXD6-A 2,3 450-600<br />

SLD6-A, SLD6-B 3 300-600<br />

SMD6, SMD6-B 3 500-800<br />

SND6, SND6-B 3 500-1200<br />

PD6, PXD6, SPD6 3 1200-1600<br />

RD6, RXD6 3 1600-2000<br />

240V Fuse Series Ratings (continued)<br />

Series<br />

Rating<br />

kAIR<br />

200,000<br />

Main Fuse<br />

Branch Breaker<br />

Type<br />

Max.<br />

Amperes<br />

Type<br />

Number<br />

of Poles<br />

Max.<br />

Amperes<br />

R<br />

125-200<br />

(2,3P)<br />

QJH2, QJ2H, QJ2 2,3 125-200<br />

T, J<br />

125-600<br />

(2,3P)<br />

QJH2, QJ2H 2,3 125-225<br />

125-400<br />

(2,3P)<br />

QJ2 2,3 125-225<br />

J, R<br />

70-600<br />

(2,3P)<br />

HFD6, HFXD6 2,3 70-250<br />

70-1200 HFD6, HFXD6 2,3 70-250<br />

T 600-1200<br />

(2,3P)<br />

NMG, HMG 2,3 600-800<br />

HFD6, HFXD6 2,3 70-250<br />

MD6, MXD6,<br />

2,3 500-800<br />

601-6000 HMD6, HMXD6<br />

L<br />

(2,3P)<br />

NMG, HMG 2,3 600-800<br />

ND6, NXD6,<br />

HND6, HNXD6<br />

2,3 500-1200<br />

J,R<br />

15-600<br />

(1,2,3P)<br />

NGB,HGB,LBG 1,2,3 15-125<br />

J,R<br />

50-600<br />

(2,3P)<br />

NDGA, HDGA 2,3 50-150<br />

J,R<br />

70-600<br />

(2,3P)<br />

NFGA, HFGA 2,3 70-250<br />

J,R<br />

200-600<br />

(2,3P)<br />

NJGA, HJGA 2,3 200-400<br />

J,R<br />

400,600<br />

(1,2,3P)<br />

NLGA, HLGA 2,3 400-600<br />

T<br />

15-1200<br />

(1,2,3P)<br />

NGB,HGB,LBG 1,2,3 15-125<br />

T<br />

50-1200<br />

(2,3P)<br />

NDGA, HDGA 2,3 50-150<br />

T<br />

70-1200<br />

(2,3P)<br />

NFGA, HFGA 2,3 70-250<br />

T<br />

200-1200<br />

(2,3)<br />

NJGA, HJGA 2,3 200-400<br />

T<br />

400-1200<br />

(2,3P)<br />

NLGA, HLGA 2,3 400-600<br />

NDGA, HDGA 2,3 50-150<br />

L<br />

601-6000 NFGA, HFGA 2,3 70-250<br />

(2,3P)<br />

NJGA, HJGA 2,3 200-400<br />

NJGA, HLGA 2,3 400-600<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-233


Molded Case Circuit Breakers<br />

Series Connected Short Circuit Ratings<br />

Revised on 03/25/17<br />

General<br />

480V Fuse Series Ratings<br />

Series<br />

Main Fuse<br />

Branch Breaker<br />

Rating<br />

kAIR Type<br />

Max.<br />

Amperes<br />

Type<br />

Number<br />

of Poles<br />

Max.<br />

Amperes<br />

50,000 J<br />

60-400 (1,2,3P) ED4 1 60-100<br />

15-400 (2,3P) ED4 2,3 15-100<br />

J 15-400 (1,2,3P) ED4 1 15-50<br />

T, J 70-600 (2,3P) FD6-A, FXD6-A 2,3 70-250<br />

J, R 70-600 (2,3P) HFD6, HFXD6 2,3 70-250<br />

JD6-A, JXD6-A<br />

2,3 200-400<br />

200-600 (2,3P) HJD6-A, HJX<br />

T, J, R<br />

LD6-A, HLD6 2,3 200-600<br />

450-600 (2,3P) LXD6-A, HLD6 2,3 450-600<br />

T 70-1200 (2,3P) HFD6, HFXD6 2,3 70-250<br />

JD6-A, JXD6-A<br />

2,3 200-400<br />

HJD6-A, HJX<br />

T, L 601-1200 (2,3P)<br />

LD6-A, HLD6 2,3 200-600<br />

LXD6-A, HLX 2,3 450-600<br />

HFD6, HFXD6 2,3 70-250<br />

MD6, MXD6<br />

HMD6, HMXD6<br />

2,3 500-800<br />

L<br />

ND6, NXD6<br />

601-6000<br />

2,3 500-1200<br />

HND6, HNXD6<br />

(2,3P)<br />

NDGA, HDGA 2,3 50-150<br />

NFGA, HFGA 2,3 70-250<br />

NJGA, HJGA 2,3 200-400<br />

100,000<br />

NLGA, HLGA 2,3 400-600<br />

J,R<br />

50-600<br />

(2,3P)<br />

NDGA, HDGA 2,3 50-150<br />

J,R<br />

70-600<br />

(2,3P)<br />

NFGA, HFGA 2,3 70-250<br />

J,R<br />

200-600<br />

(2,3P)<br />

NJGA, HJGA 2,3 200-400<br />

J,R<br />

400-600<br />

(2,3P)<br />

NLGA, HLGA 2,3 400-600<br />

T<br />

601-1200<br />

(2,3P)<br />

NDGA, HDGA 2,3 50-150<br />

T<br />

601-1200<br />

(2,3P)<br />

NFGA, HFGA 2,3 70-250<br />

T<br />

601-1200<br />

(2,3P)<br />

NJGA, HJGA 2,3 200-400<br />

T<br />

601-1200<br />

(2,3P)<br />

NLGA, HLGA 2,3 400-600<br />

NDGA, HDGA 2,3 50-150<br />

L 601-6000 (2,3P)<br />

NFGA, HFGA 2,3 70-250<br />

NJGA, HJGA 2,3 200-400<br />

NLGA, HLGA 2,3 200-400<br />

200,000<br />

R 15-100 (1,2,3P)<br />

BQD, CQD 1 15-100<br />

BQD, CQD 2,3 20-30<br />

T, J 15-200 (1,2,3P)<br />

BQD, CQD 1 15-100<br />

BQD, CQD 2,3 20-30<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

7<br />

7-234<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Molded Case Circuit Breakers<br />

IEC 947-2® AC Interrupting Ratings, 50/60 HZ KA<br />

Revised on 05/31/18<br />

Reference<br />

Ampere Breaker Breaker<br />

220/240 Volts 380/415 Volts 500 Volts<br />

Rating Frame Type<br />

Icu Ics Icu Ics Icu Ics<br />

15-125 ED ED6 65 17 35 9 — —<br />

FXD6 65 33 35 18 — —<br />

70-250 FD<br />

HFXD6 100 50 65 33 — —<br />

HHFXD6 200 100 100 50 — —<br />

250-400 JD<br />

JXD6(A) 65 33 40 20 — —<br />

HJXD6(A) 100 50 65 33 — —<br />

400-600 LD LXD6(A) 65 33 40 20 — —<br />

HLXD6(A) 100 50 65 33 — —<br />

600-800 MD<br />

MXD6 65 33 40 20 — —<br />

HMXD6 100 50 65 33 — —<br />

800-1200 ND<br />

NXD6 65 33 40 20 — —<br />

HNXD6 100 50 65 33 — —<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-235


Molded Case Circuit Breakers<br />

Typical Specifications<br />

Reference<br />

General Specifications<br />

Molded case circuit breakers shall provide circuit overcurrent protection with<br />

inverse time and instantaneous tripping characteristics and shall be Siemens<br />

Sentron, Sensitrip or approved equal.<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

All circuit breakers shall be listed by Underwriters’ Laboratories, Inc., conform<br />

to applicable requirements of NEMA Standard Publication No. AB1 and meet<br />

appropriate classifications of Federal Specifications W C 375B/Gen.<br />

All circuit breakers shall have a quick-make, quick-break over center toggle type<br />

mechanism and the handle mechanism shall be trip free to prevent holding contacts<br />

closed against a short circuit or sustained overload. All circuit breaker handles shall<br />

assume a position between “ON” and “OFF when tripped automatically. Multi-pole<br />

circuit breakers shall be common-trip such that an overload or short circuit on any<br />

one pole will result in all poles opening simultaneously. Arc extinction is to be<br />

accomplished by magnetic arc chutes. All ratings are to be clearly visible. When<br />

reverse feed is indicated on the drawings, in accordance with UL, circuit breakers<br />

with sealed trip units shall be supplied.<br />

Thermal Magnetic Specifications<br />

Unless otherwise noted on the drawings, all Circuit breakers 2000 Ampere<br />

and below shall have thermal-magnetic trip units, with inverse time-current<br />

characteristics. Automatic operation of these circuit breakers shall be obtained by<br />

means of thermal-magnetic tripping devices located in each pole providing inverse<br />

time delay and instantaneous circuit protection. Circuit breakers shall be ambient<br />

compensating in that, as the ambient temperature increases over 40°C, the circuit<br />

breaker automatically derates itself so as to better protect its associated conductor.<br />

Thermal magnetic breakers from 250 to 2000A frames shall have thermal<br />

interchangeable trip units, with instantaneous magnetic trip settings that are<br />

adjustable and accessible from the front of all circuit breakers on frame sizes 250<br />

Amperes and above. Where indicated, provide circuit breakers UL listed for<br />

application at 100% of their continuous ampere rating in their intended enclosure.<br />

Motor Circuit Protectors<br />

Where indicated on the drawings and in the combination motor starter/motor<br />

control center schedule, furnish instantaneous magnetic trip only circuit breakers<br />

for motor short circuit protection. The magnetic trips shall be adjustable and<br />

accessible from the front of all circuit breakers frames. The continuous current<br />

rating shall be between 1 and 800 Amperes as indicated on the drawing.<br />

The interrupting rating of the circuit breakers shall be as indicated in the<br />

specifications, and shown on the drawing or single line diagram. The interrupting<br />

rating of the circuit breakers shall be at least equal to the available short circuit<br />

current at the line terminals of the circuit breaker and correspond to the UL listed<br />

integrated short circuit current rating specified.<br />

Internal Accessories<br />

Provide shunt trips, bell alarms, and auxiliary switches as shown on the contract<br />

drawings. Gold plated auxiliary switches shall be supplied for PLC connection. Internal<br />

accessories for all breakers shall be UL listed for field installation and modification.<br />

Solid State Sensing Specifications<br />

As indicated on the drawings, circuit breaker frames<br />

400 Ampere through 3200-Ampere shall have<br />

microprocessor-based RMS sensing trip units, with<br />

the capability to measure through to the 21st harmonic.<br />

Automatic operation of all circuit breaker frames 400A<br />

and larger shall be obtained by means of solid state<br />

tripping elements providing inverse time delay and<br />

(instantaneous) and/or (short-time delay) circuit<br />

protection. Continuous current ratings shall be adjustable<br />

from 20% to 100% of the trip unit rating, without the need<br />

for a rating plug. Long-time delay and instantaneous trip<br />

shall be adjustable. The optional short-time trip function<br />

shall have adjustable pick-up settings, three fixed times,<br />

and I 2 t ramp. Circuit breaker frames 400A and larger, and<br />

where indicated on the drawings, shall be 100% equipment<br />

rated.<br />

Integral Ground<br />

Fault Option<br />

Main and feeder circuit breakers, as indicated on the<br />

drawings, shall be provided with integral ground fault<br />

protection. Ground fault pick-up shall be adjustable from<br />

20% to 70% of the circuit breakers maximum continuous<br />

current rating. Ground fault time delay shall be adjustable<br />

with three 1 2 t ramps.<br />

Metering Option<br />

When indicated on the drawings, solid state trip breakers<br />

shall be furnished with a plug-in or panel mounted<br />

metering device. This device shall simultaneously display<br />

all three phase currents, as well as average current,<br />

ground current, and phase unbalance. In addition it shall<br />

display breaker status, a max log, and a trip log. The trip<br />

log will retain and display date, time and type of trip<br />

(overload, short circuit or ground fault) for the most<br />

recent 5 trip events.<br />

Current Limiting Specifications<br />

Where indicated on the drawings, Siemens current<br />

limiting circuit breakers are to be furnished. Current<br />

limiting circuit breakers shall limit the let-through I 2 t to a<br />

value less than the I 2 t of one-half cycle wave of the<br />

symmetrical prospective current without any fusible<br />

elements when operating within its current range.<br />

Series Connected Combination Specifications<br />

Where protective devices are applied in series combination,<br />

such that the prospective available fault current exceeds<br />

the interrupting rating (AIR) of the downstream protective<br />

devices, such combinations shall be UL recognized<br />

combinations. All electrical equipment using these UL<br />

recognized circuit breaker combinations shall be clearly<br />

marked in accordance with NEC Section 240-83(c).<br />

Connection Accessories<br />

Unless otherwise noted, Mechanical lugs shall be provided with all Molded Case<br />

Breakers. Where indicated on the drawings, compression lugs shall be provided on<br />

1200 Ampere frame and below circuit breakers. All compression lugs shall be<br />

supplied by the Circuit Breaker Manufacturer. Where indicated on the drawings,<br />

UL listed plug-in or rear connectors shall be supplied.<br />

7-236<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Molded Case Circuit Breakers<br />

Superseded Breakers<br />

General<br />

Sentron Series Note Superseded Note Superseded<br />

CED62B015-CED62B125<br />

a<br />

CLE62B015-CLE62B100<br />

c<br />

CE2B015-CE2B100<br />

CED62S100A<br />

a<br />

CLE62S100<br />

c<br />

CE2S100<br />

CED63A001-CED63A125<br />

a<br />

CLE63A001-CLE63A125<br />

CED63B015-CED63B125<br />

a<br />

CLE63B015-CLE63B100<br />

c<br />

CE3B015-CEB100<br />

CED63S100A<br />

a<br />

CLE63S100<br />

c<br />

CE3S100<br />

HHED63B015-HHED63B125<br />

a<br />

HED63B015-HED63B125<br />

CFD62A150, CFD62L150, CFD62A250<br />

a<br />

CLF62A150, CLF62A250<br />

CFD62B070-CFD62B250<br />

a<br />

CLF62B070-CLF62B240<br />

c<br />

CJ2B125-CJ2B250<br />

CFD62S250A<br />

a<br />

CLF62S250<br />

CFD63A150, CFD63L150, CFD63A250<br />

a<br />

CLF63A150, CLF63A250<br />

CFD63B070-CFD63B250<br />

a<br />

CLF63B070-CLF63B250<br />

c<br />

CJ3B125-CJ3B250<br />

CFD63S250A<br />

a<br />

CLF63S250<br />

CJD62B200-CJD62B400<br />

a<br />

CLJ62B100-CLJ62B400<br />

d<br />

CJ2B300-CJ2B400<br />

CJD62H400, CJD62L400<br />

a<br />

CLJ62L400, CLJ62H400<br />

CJD62S400A<br />

a<br />

CLJ62S400<br />

d<br />

CJ2S400<br />

CJD63B200-CJD63B400<br />

a<br />

CLJ63B200-CLJ63B400<br />

d<br />

CJ3B300-CJ3B400<br />

CJD63H400, CJD63L400<br />

a<br />

CLJ63L400, CLJ63H400<br />

CJD63S400A<br />

a<br />

CLJ63S400<br />

d<br />

CJ3S400<br />

CPD63B120-CPD63B160<br />

e<br />

CP3B120-CP3B160<br />

ED21B015-ED21B100<br />

a<br />

E21B015-E21B100<br />

b<br />

EE1B015-EE1B100<br />

ED22B015-ED22B100<br />

a<br />

E22B015-E22B100<br />

b<br />

EE2B015-EE2B100<br />

ED22S100A<br />

a<br />

E22S100A<br />

b<br />

EE2S100<br />

ED23B015-ED23B100<br />

a<br />

E23B015-E23B100<br />

b<br />

EE3B015-EE3B100<br />

ED23S100A<br />

a<br />

E23S100A<br />

b<br />

EE3S100<br />

ED41B015-ED41B100<br />

a<br />

E41B015-E41B100<br />

b<br />

EH1B015-EH1B100<br />

ED42B015-ED42B125<br />

a<br />

E42B015-E42B100<br />

b<br />

EH2B015-ED2B125<br />

ED42S100A<br />

a<br />

E42S100<br />

b<br />

EH2S100<br />

ED43B015-ED43B125<br />

a<br />

E43B015-E43B100<br />

b<br />

EH3B015-EH3B100<br />

ED43S100A<br />

a<br />

E43S100<br />

b<br />

EH3S100<br />

ED61B015-ED61B100<br />

a<br />

E61B015-E61B100<br />

b<br />

EF1B015-EF1B020<br />

ED62B015-ED62B125<br />

a<br />

E62B015-E62B100<br />

b<br />

EF2B015-EF2B100<br />

ED62S100A<br />

a<br />

E62S100A<br />

b<br />

EF2S100<br />

ED63A001-ED63A125<br />

a<br />

E63A001-E63A125<br />

b<br />

EF3A003, EF3J050, EF3L050-EF3A100, EF3H1<br />

ED63B015-ED63B125<br />

a<br />

E63B015-E63B100<br />

b<br />

EF3B015-EF3B100<br />

ED63S100A<br />

a<br />

E63S100A<br />

b<br />

EF3S100<br />

HHED63B015-HHED63B125<br />

a<br />

HED63B015-HED63B125<br />

FD62B070-FD62B250 f a F62B070, F62B250<br />

FD63B070-FD63B250 f a F63B070-F63B250<br />

FXD62A150, FXD62L150, FXD62A250<br />

a<br />

FJ62A150, FJ62L150-FJ62A250<br />

FXD62B070-FXD62B250 f a FJ62B070-FJ62B250<br />

b<br />

FJ2B070-FJ2B225<br />

FXD62S250A<br />

a<br />

FJ62S250<br />

b<br />

FJ2S225<br />

FXD63A150, FXD63L150, FXD63A250<br />

a<br />

FJ63A150, FJ63L150-FJ63A250<br />

b<br />

FJ3A225<br />

FXD63B070-FXD63B250 f a FJ63B070-FJ63B250<br />

b<br />

FJ3B070-FJ3B225<br />

FXD63S250A<br />

a<br />

FJ63S250<br />

b<br />

FJ3S225<br />

HED41B015-HED41B100<br />

a<br />

HE41B015-HE41B100<br />

HED42B015-HED42B125<br />

a<br />

HE42B015-HE42B100<br />

HED43B015-HED43B125<br />

a<br />

HE43B015-HE43B100<br />

HED61B015-HED61B100<br />

a<br />

HE61B015-HE61B100<br />

b<br />

HE2B015-HE2B100<br />

HED63B015-HED63B125<br />

a<br />

HE63B015-HE63B100<br />

b<br />

HE3B015-HE3B100<br />

HFD62B070-HFD62B250<br />

a<br />

HF62B070-HF62B250<br />

HFD63B070-HFD63B250<br />

a<br />

HF63B070-HF63B250<br />

HHED63B015-HHED63B125<br />

a<br />

HED63B015-HED63B125<br />

HJD63B200-HJD63B400<br />

a<br />

HJ63B200-HJ63B400<br />

b<br />

HJ3B125-HJ3B400<br />

HLD63B250-HLD63B600<br />

a<br />

HL63B450-HL63B600<br />

b<br />

HL3B450-HL3B600<br />

HMD63B500-HMD63B800<br />

b<br />

HN3B500-HN3B800<br />

HND63B100-HND63B120<br />

b<br />

HK3B100-HK3B120<br />

HPD63B120-HPD63B160<br />

b<br />

HP3B120-HP3B160<br />

HRD63B160-HRD63B200<br />

b<br />

HR3B160-HR3B200<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

aMechanically and electrically interchangeable.<br />

bElectrically interchangeable only, refer to sales office for<br />

further details.<br />

cElectrically interchangeable only if the system interrupting<br />

capacity is less than or equal to:<br />

200 kA at 240V AC<br />

200 kA at 480V AC<br />

100 kA at 600V AC<br />

dElectrically interchangeable only if the system interrupting<br />

capacity is less than or equal to:<br />

200 kA at 240V AC<br />

150 kA at 480V AC<br />

100 kA at 600V AC<br />

eRefer to local sales office for replacement information.<br />

fEffective 1994 — The FD6 and FXD6 types have been<br />

replaced by FD6-A and FXD6-A type thermal / magnetic<br />

circuit breakers — mechanically and electrically<br />

interchangeable with the exception that FXD6-A and FD6-A<br />

have 22kA at 600V AC ratings versus 18kA at 600V AC for<br />

types FXD6 and FD6.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-237


Molded Case Circuit Breakers<br />

Superseded Breakers<br />

Revised on 02/06/18<br />

General<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Sentron Series Note Superseded Note Superseded<br />

JD62B200-JD62B400 a JLB200-JL62B400 b JL2B070-JL2B400<br />

JD63B200-JD63B400 a JL63B200-JL63B400 b JL3B0L0-JL3B400<br />

JXD22B200-JXD22B400 a JD22B200-JD22B400 b JD2B250-JD2B400<br />

JXD22S400A a JD22S400 b JD2S400<br />

JXD23B200-JXD23B400 a JD23B200-JD23B400 b JD3B250-JD3B400<br />

JXD23S400A a JD23S400 b JD3S400<br />

JXD62B200-JXD62B400 a JJ62B200-JJ62B400 b JJ2B250-JJ2B400<br />

JXD62H400, JXD62L400 a JL62L400, JL62H400 b JL2L400-JL2H400<br />

JXD62S400A a JJ62S400A<br />

JXD63B200-JXD63B400 a JJ63B200-JJ63B400 b JJ3B200-JJ3B400<br />

JXD63H400, JXD63L400 a JL63A400, JL63H400, JL63L400 b JL3H400, JL3L400, JL3A225<br />

JXD63S400A a JJ63S400A<br />

LD62B250-LD62B500 a LL63B250-LL62B600 b LL2B450-LL2B600<br />

LD62B250-LD63B600 a LL63B250-LL63B600 b LL3B450-LL3B600<br />

LXD62B450-LXD62B600 a LJ62B450-LJ62B600<br />

LXD62J600, LXD62L600 b LL2H600, LL2U600, LL2X600<br />

LXD62S600A a LJ62S600<br />

LXD63B450-LXD63B600 a LJ63B450-LJ63B600<br />

LXD64H600, LXD63L600 a LL63H600, LL63L600 b LL3A450, LL3H600<br />

LXD63S600A a LJ63S600A b LL3S600<br />

MD62B500-MD62B800 b KM2B500-KM2B800<br />

MD63B500-MD63B800 b KM3B500-KM3B800<br />

MXD62A800, MXD62H800, MXD62L800 b KM2A800, KM2H800, KM2L800<br />

MXD62S800A b KM2S800<br />

MXD63A800, MXD63H800, MXD63L800 b KM3A600, KM3H800, KM3L800<br />

MXD63S800A b KM3S800<br />

ND63B100-ND63B900 b KP3B100-KP3B900<br />

NXD63S120A b KP3S120<br />

PD63B120-PD63B160 b HP3B120-HP3B160<br />

PXD63S160A b HP3S160<br />

RD63B160-RD63B200 b HR3B160-HR3B200<br />

QR22B100 – QR22B225<br />

QJ22B060-QJ22B225<br />

QR22B100H – QR22B225H<br />

QJ22B060H-QJ22B225H<br />

HQR23S250HA<br />

QJ22S225<br />

QJ23B100 – QR23B225<br />

QJ23B060-QJ23B225<br />

QR23B100H – QR23B225H<br />

QJ23B060H-QJ23B225H<br />

QRH22B100 – QRH22B225<br />

QJH22B060-QJH22B225<br />

QRH23B100 – QRH23B225<br />

QJH23B060-QJH23B225<br />

HQR23S250HA QJH23S225 a<br />

QJH22B060-QJH22B225 a QJ2H125-QJ2B225<br />

QJH23B060-QJH23B225 a QJ3H125-QJ3H225<br />

QJH23S225 a QJ3S225<br />

RD63B160-RD63B200 b HR3B160-HR3B200<br />

RXD63S200A b HR3S200<br />

SCJD6B200LI-SCJD6B400LI a SCJD69200-SCJD69400<br />

SCJD6B200LIG-SCJD6B400LIG a SCJD69200G-SCJD69400G<br />

SCJD6B200LSIG-SCJD6B400LSIG a SCJD69200NGT-SCJD69400NGT<br />

SCJD6B200LSI-SCJD6B400LSI a SCJD69200NT-SCJD69400NT<br />

SCLD6B300LI-SCLD6B600LI a SCLD69300-SCLD69600<br />

SCLD6B300LIG-SCLD6B600LIG a SCLD69300G-SCLD69600G<br />

SCLD6B300LSIG-SCLD6B600LSIG a SCLD69300NGT-SCLD69600NGT<br />

SCLD6B300LSI-SCLD6B600LSI a SCLD69300NT-SCLD69600NT<br />

SCMD6B600LI-SCMD6B800LI a SCMD69600A-SCMD69800A<br />

SCMD6B600LIG-SCMD6B800LIG a SCMD69600AG-SCMD69800AG<br />

SCMD6B600LSIG-SCMD6B800LSIG a SCMD69600ANGT-SCMD69800ANGT<br />

SCMD6B600LSI-SCMD6B800LSI a SCMD69600ANT-SCMD69800ANT<br />

aMechanically and electrically interchangeable.<br />

bElectrically interchangeable only, refer to sales office for<br />

further details.<br />

cElectrically interchangeable only if the system<br />

interrupting capacity is less than or equal to:<br />

200 kA at 240V AC<br />

200 kA at 480V AC<br />

100 kA at 600V AC<br />

dElectrically interchangeable only if the system<br />

interrupting capacity is less than or equal to:<br />

200 kA at 240V AC<br />

150 kA at 480V AC<br />

100 kA at 600V AC<br />

eRefer to local sales office for replacement information.<br />

7-238<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Molded Case Circuit Breakers<br />

Superseded Breakers<br />

Revised on 02/06/18<br />

General<br />

Sentron Series Note Superseded Note Superseded<br />

SCND6B800LI-SCND6B120LI a SCND69800A-SCND69120A<br />

SCND6B800LIG-SCND6B120LIG a SCND69800AG-SCND69120AG<br />

SCND6B800LSIG-SCND6B120LSIG a SCND69800ANGT-SCND69120ANGT<br />

SCND6B800LSI-SCND6B120LSI a SCND69800ANT-SCND69120ANT<br />

SHJD6B200LI-SHJD6B400LI a SHJD69200-SHJD69400 a SHJ63B200-SHJ63B400G<br />

SHJD6B200LIG-SHJD6B400LIG a SHJD69200G-SHJD69400G a SHJ63B200G-SHJ63B400G<br />

SHJD6B200LSIG-SHJD6B400LSIG a SHJD69200NGT-SHJD69400NGT a SHJ63N200G-SHJ63N400G<br />

SHJD6B200LSI-SHJD6B400LSI a SHJD69200NT-SHJD69400NT a SHJ63N200-SHJ63N400<br />

SHLD6B300LI-SHLD6B600LI a SHLD69300-SHLD69600 a SHL63B300-SHL63B600<br />

SHLD6B300LIG-SHLD6B600LIG a SHLD69300G-SHLD69600G a SHL63B300G-SHL63B600G<br />

SHLD6B300LSIG-SHLD6B600LSIG a SHLD69300NGT-SHLD69600NG a SHL63N300G-SHL63N600G<br />

SHLD6B300LSI-SHLD6B600LSI a SHLD69300NT-SHLD69600NT a SHL63N300-SHL63N600<br />

SHND6B100LI-SHND6B120LI a SHND69100A-SHND69120A a SHND69100-SHND69800<br />

SHND6B100LIG-SHND6B120LIG a SHND69100AG-SHND69120AG a SHND69100G-SHND69800G<br />

SHPD6B140LI-SHPD6B160LI a SHPD69140-SHPD69160 b SHPF3B120-SHPF3B160<br />

SHPD6B140LIG-SHPD6B160LIG a SHPD69140G-SHPD69160G b SHPF3B120G-SHPF3B160G<br />

SHND6B100LSIG-SHND6B120LSIG a SHND69100NGT-SHND69800NGT a SHKF3N100G-SHKF3N800G<br />

SHND6B100LSI-SHND6B120LSI a SHND69100NT-SHND69800NT b SHKF3N100-SHKF3N800<br />

SJD6B200LI-SJD6B400LI a SJD69200-SJ369400 a SJL63B200-SJL63B400<br />

SJD6B200LIG-SJD6B400LIG a SJD69200G-SJD69400G a SJL63B200G-SJL63B400G<br />

SJD6B200LSIG-SJD6B400LSIG a SJD69200NGT-SJD69400NGT a SJL63N200G-SJL63N400G<br />

SJD6B200LSI-SJD6B400LSI a SJD69200NT-SJD69400NT a SJL63N200-SJL63N400<br />

SLD6B300LI-SLD6B600LI a SLD69300-SLD69600 a SLL63B300-SLL63B600<br />

SLD6B300LIG-SLD6B600LIG a SLD69300G-SLD69600G a SLL63B300G-SLL63B600G<br />

SLD6B300LSIG-SLD6B600LSIG a SLD69300NGT-SLD69600NGT a SLL63N300G-SLL63N600G<br />

SLD6B300LSI-SLD6B600LSI a SLD69300NT-SLD69600NT a SLL63N300-SLL63N600<br />

SMD6B600LI-SMD6B800LI a SMD69600A-SMD69800A a SMD69600-SMD69800<br />

SMD6B600LIG-SMD6B800LIG a SMD69600AG-SMD69800AG a SMD69600G-SMD69800G<br />

SMD6B600LSIG-SMD6B800LSIG a SMD69600ANGT-SMD69800ANGT a SMD69600NGT-SMD69800NGT<br />

SMD6B600LSI-SMD6B800LSI a SMD69600ANT-SMD69800ANT a SMD69600NT-SMD69800NT<br />

SND6B800LI-SND6B120LI a SND69800A-SND69120A a SND69100-SND69800<br />

SND6B800LIG-SND6B120LIG a SND69800AG-SND69120AG a SND69100G-SND69800G<br />

SND6B800LSIG-SND6B120LSIG a SND69800ANGT-SND69120ANGT a SND69100NGT-SND69800NGT<br />

SND6B800LSI-SND6B120LSI a SND69800ANT-SND69120ANT a SND69100NT-SND69800NT<br />

SHPD6B140LI-SHPD6B160LI a SPD69140-SPD69160 b SHPF3B120-SHPF3B160<br />

SHPD6B140LIG-SHPD6B160LIG a SPD69140G-SPD69160G b SHPF3B120G-SHPF3B160G<br />

SHPD6B140LSIG-SHPD6B160LSIG a SPD69140NGT-SPD69160NGT b SHPF3N120-SHPF3N160G<br />

SHPD6B140LSI-SHPD6B160LSI a SPD69140NT-SPD69160NT b SHPF3N120G-SHPF3N160G<br />

— — d BQCC1B015-BQC1B030<br />

— — d CC1B015-CC1B030<br />

— — d CC2B015-CC2B030<br />

— — d CC3B015-CC3B030<br />

— — d EF2A003, EF2H050, EF2L050, EF2A100<br />

— — d EF2H150, EF2L150<br />

— — d EH1B015-EH1B100<br />

— — d EH2B015-EH2B100<br />

— — d EH3B015-EH3B100<br />

— — c HE2A003, HE2H050, HE2L050-HE2A100<br />

— — c HE3A003, HE3H050, HE3L050-HE3A100<br />

— — c HE3B015-HE3B100<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

aMechanically and electrically interchangeable.<br />

bElectrically interchangeable only, refer to sales<br />

office for further details.<br />

cThese units are for replacement purposes only.<br />

Consult sales office for availability.<br />

dThese units are no longer manufactured, and no<br />

replacement is available.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-239


Molded Case Circuit Breakers<br />

Notes<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

7<br />

7-240<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Transformers<br />

SPEEDFAX TM<br />

Section<br />

Sentron Power Centers<br />

C o n t e n t s<br />

Transformer—Dry Type Distribution 8-2 – 8-3<br />

Features and Technical Information 8-4<br />

Catalog Coding System 8-5 – 8-8<br />

Single Phase—Distribution Dry Type 8-9 - 8-10<br />

Three Phase—Distribution Dry Type 8-11 - 8-14<br />

Filtered Isolation and Motor Drive 8-15<br />

Sentron Power Centers 8-16 - 8-17<br />

High Efficiency Transformers 8-18<br />

Harmonic Mitigation Transformers 8-19 - 8-20<br />

Buck-Boost Transformers<br />

Buck-Boost Application, Selection Tables 8-21 - 8-24<br />

Buck Boost Single Phase and Three Phase Connection Diagrams 8-25 - 8-26<br />

Accessories for Transformers: Lugs, Drip Shields and Wall Brackets 8-27<br />

Harmonic Mitigating Transformers<br />

8 TRANSFORMERS<br />

Buck-Boost Transformers<br />

Scan to connect<br />

online to the<br />

most up-todate<br />

version of<br />

this Section of<br />

SPEEDFAX.<br />

(Section was last modified on 01/08/20)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 8-1


Transformers<br />

Dry Type Distribution 600 Volt Class <br />

General<br />

Siemens dry type distribution transformers<br />

are rated 600 volt class and are<br />

available in a wide variety of ratings to<br />

provide versatile electrical distribution<br />

for general purpose, lighting and power<br />

loads in commercial and industrial<br />

applications.<br />

Ratings are available from 0.25 through<br />

167 kVA single phase, and 3 through<br />

1000 kVA 3-phase. A variety of primary<br />

and secondary voltage ratings are<br />

available to match the load requirements<br />

to the distribution system. All units meet<br />

applicable ANSI and NEMA standards.<br />

Standard designs are UL Listed.<br />

Transformers are designed, manufactured,<br />

and tested in accordance with<br />

ANSI, NEMA and IEEE Standards and<br />

are UL Listed. All units are fungus resistant.<br />

Fungus proof is not an option.<br />

Encapsulated Transformer<br />

Ventilated Transformer<br />

Encapsulated<br />

n The self-cooled kVA rating shall be<br />

suitable for 30°C average, 40°C<br />

maximum ambient temperature.<br />

n Ratings from 0.25 kVA through 25<br />

kVA,1-phase, and from 3 kVA through<br />

15 kVA 3-phase are available.<br />

n Feature indoor/outdoor enclosures<br />

with integral wall mounting brackets,<br />

and either a 135°C rise, 180°C insulation<br />

system or a 95°C rise, 130°C<br />

insulation system.<br />

Ventilated<br />

n Ratings from 15 kVA through 167 kVA<br />

1- phase, and from 15 kVA through<br />

1000 kVA 3-phase are available.<br />

n Indoor NEMA 1/3R enclosures with<br />

150oC rise and 220oC insulation<br />

systems are standard. Many options<br />

are available. <br />

n Most three phase designs (15 kVA<br />

through 75kVA) and single phase<br />

designs (15 kVA through 50kVA)<br />

include primary and secondary<br />

terminal lugs. For more information,<br />

refer to lug table on page 8-8<br />

Call customer support for confirmation<br />

if needed.<br />

n 1-phase up to 167 kVA and 3-phase<br />

up to 750kVA are Seismic certified<br />

for floor mounting. Call customer support<br />

for larger kVA certification or wall<br />

mounting applications.<br />

DOE 2016 Efficiency Standards<br />

8<br />

TRANSFORMERS<br />

n Department of Energy (DOE)<br />

10 CFR 431 released efficiency<br />

standards which will take effect<br />

January 1, 2016.<br />

n New efficiency standards apply<br />

to dry-type three-phase ventilated<br />

transformers, including Harmonic<br />

Mitigating Transformers from<br />

15 kVA to 1000kVA<br />

n New standards will surpass and<br />

supersede NEMA TP1 standards and<br />

will make NEMA Premium obsolete.<br />

n DOE 2016 designs have grainoriented,<br />

non-aging silicon steel.<br />

n Dry type, three phase ventilated<br />

transformers must be manufactured<br />

to DOE 2016 standards after January<br />

1, 2016<br />

n NEMA TP1 rated transformers will<br />

still be available for single phase<br />

transformers after January 1, 2016<br />

n See accompanying chart for efficiency<br />

increases for DOE 2016 standards.<br />

Comparison of 3-Phase<br />

LV Transformer Efficiency<br />

kVA<br />

TP1<br />

NEMA<br />

Premium <br />

DOE<br />

2016<br />

15 97.00% 97.90% 97.89%<br />

30 97.50% 98.25% 98.23%<br />

45 97.70% 98.39% 98.40%<br />

75 98.00% 98.60% 98.60%<br />

112.5 98.20% 98.74% 98.74%<br />

150 98.30% 98.81% 98.83%<br />

225 98.50% 98.95% 98.94%<br />

300 98.60% 99.02% 99.02%<br />

500 98.70% 99.09% 99.14%<br />

750 98.80% 99.16% 99.23%<br />

1000 98.90% 99.23% 99.28%<br />

a NEMA Premium will no longer be available after<br />

January 1, 2016 due to DOE 2016 requirements.<br />

8-2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Distribution Dry Type Transformers<br />

Revised on 04/17/17<br />

600 Volts Class — Single and Three Phase Selection<br />

600 Volts Class<br />

Single Phase 0.25-167 kVA<br />

Three Phase 3-1000 kVA<br />

Features<br />

n Standard units are UL listed and are<br />

designed in accordance with ANSI,<br />

NEMA (ST20) and IEEE standards<br />

Encapsulated<br />

n UL listed designs (UL 506)<br />

n Totally enclosed, non-ventilated, heavy<br />

gauge steel enclosure<br />

n Core and coil completely embedded<br />

within a resin compound for quiet, low<br />

temperature operation<br />

n Encapsulation seals out moisture and air<br />

n UL listed indoor/outdoor enclosure<br />

features integral wall mounting brackets<br />

n Rugged design resists weather, dust,<br />

and corrosion<br />

n Efficient, compact, lightweight, easy<br />

to install<br />

n Flexible wiring leads that terminate<br />

within the bottom wiring compartment<br />

n Large wiring compartment on the<br />

bottom with convenient knockouts<br />

n High quality non-aging electrical grade<br />

core steel<br />

n Precision wound coils<br />

Ventilated<br />

n UL listed designs (UL 1561)<br />

n Designed for indoor NEMA 2 installations.<br />

NEMA 3R enclosures suitable for<br />

outdoor locations available as an option<br />

n All D16 catalog numbers include NEMA<br />

3R enclosures as standard unless other<br />

options chosen change or remove the<br />

enclosure<br />

n Core and coils are designed with UL<br />

listed high-temperature materials rated<br />

for 220°C; standard units feature 150°C<br />

winding temperature rise<br />

n Optional low temperature rise of 115°<br />

C or 80° C winding temperature rise for<br />

increased efficiency and additional overload<br />

capability<br />

n Rugged sheet steel enclosure per<br />

UL1561, UL506 standards with removable<br />

panels for access to the internal<br />

wiring area<br />

n Neoprene noise dampening pads isolate<br />

the core and coil from the enclosure<br />

n Optional drip shields/weathershield and<br />

wall brackets available<br />

n High quality grain-oriented, non-aging<br />

silicon steel core for 3 Phase units<br />

Single Phase Transformer Ampere Ratings<br />

Single Phase Full Load Amperes (FLC)<br />

kVA 120V 208V 240V 277V 480V 600V<br />

0.25 2.0 1.2 1.0 0.9 0.5 0.4<br />

0.50 4.2 2.4 2.1 1.8 1.0 0.8<br />

0.75 6.3 3.6 3.1 2.7 1.6 1.3<br />

1 8.3 4.8 4.2 3.6 2.1 1.7<br />

1.5 12.5 7.2 6.2 5.4 3.1 2.5<br />

2 16.7 9.6 8.3 7.2 4.2 3.3<br />

3 25 14.4 12.5 10.8 6.2 5<br />

5 41 24 20.8 18.0 10.4 8.3<br />

7.5 62 36 31 27 15.3 12.5<br />

10 83 48 41 36 20.8 16.7<br />

15 125 72 62 54 31 25<br />

25 206 120 104 90 52 41<br />

37.5 312 180 156 135 76 62<br />

50 416 240 208 180 104 83<br />

75 625 340 312 270 156 125<br />

100 833 480 416 361 208 166<br />

167 1391 803 695 603 347 278<br />

Three Phase Transformer Ampere Ratings<br />

Three Phase Full Load Amperes (FLC)<br />

kVA 208V 240V 480V 600V<br />

3 8.3 7.2 3.6 2.9<br />

6 16.6 14.4 7.2 5.8<br />

9 25 21.6 10.8 8.6<br />

15 41.7 36.1 18.0 14.4<br />

30 83.4 72.3 36.1 28.9<br />

45 124 108 54.2 43.4<br />

75 208 180 90 72<br />

112.5 312 270 135 108<br />

150 416 360 180 144<br />

225 624 541 270 216<br />

300 832 721 360 288<br />

500 1387 1202 601 481<br />

750 2084 1806 903 723<br />

1000 2779 2408 1204 963<br />

Insulation Class and Temperature Rise a<br />

kVA<br />

Insulation<br />

1-Phase 3-Phase Temperature Class Temperature Rise<br />

0.25-1 N/A 130° C 95° C<br />

1.5-25 3-15 180° C 135° C<br />

15-167 15-1000 220° C 150° C<br />

Sound Level in Decibels – 600V Class<br />

Self Cooled Ventilated Self<br />

kVA<br />

K Factor:<br />

1, 4, 9<br />

K Factor:<br />

13, 20<br />

Cooled<br />

Sealed kVA<br />

NEMA Average DB<br />

a Temp rise and insulation system values shown are<br />

typical. Variation in these values may exist depending<br />

on size, design and series. but will comply with the<br />

requirements of UL506 and UL1561<br />

Self Cooled Ventilated<br />

K Factor:<br />

1, 4, 9<br />

K Factor:<br />

13, 20<br />

NEMA Average DB<br />

0-3.00 40 40 45 112.51-150.00 50 53 55<br />

3.01-9.00 40 40 45 150.01-225.00 55 58 57<br />

9.01-15.00 45 45 50 225.01-300.00 55 58 57<br />

15.01-30.00 45 45 50 300.01-500.00 60 63 59<br />

30.01-50.00 45 48 50 500.01-700.00 62 65 61<br />

50.01-75.00 50 53 55 700.01-1000.00 64 67 63<br />

75.01-112.50 50 53 55<br />

Self<br />

Cooled<br />

Sealed<br />

8 TRANSFORMERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 8-3


Transformers<br />

Dry Type Distribution 600 Volt Class <br />

Revised on 04/17/17<br />

Specifications<br />

8<br />

TRANSFORMERS<br />

Standard Construction Features<br />

Transformers rated 15 kVA and larger<br />

shall be a ventilated dry type with a<br />

UL Listed 220°C insulation system.<br />

Units shall be designed to operate with<br />

a rated maximum temperature rise of<br />

150°C (Optional 115°C or 80°C rise can<br />

be specified).<br />

Construction shall consist of aluminum<br />

windings and arranged to brace coil<br />

layers and provide maximum ventilation.<br />

(Optional copper windings can be specified).<br />

3-Phase cores shall be constructed<br />

of grain-oriented, non-aging silicon steel<br />

with high magnetic permeability and<br />

low loss characteristics.<br />

Core laminations shall be tightly<br />

assembled. The complete core and coil<br />

assembly shall be impregnated with<br />

non-hydroscopic thermo-setting varnish<br />

to provide a high dielectric, moisture<br />

resistant, flame retardant seal that is<br />

inherently fungus-resistant.<br />

Core and coil assemblies shall be<br />

constructed to provide short circuit with<br />

stand capability as defined by ANSI and<br />

NEMA standards. The complete assembly<br />

shall be installed on vibration dampening<br />

pads to reduce noise and will be<br />

securely bolted to the enclosure base.<br />

A flexible grounding conductor shall<br />

be installed between the core and coil<br />

assembly and the transformer enclosure.<br />

Enclosures shall be ventilated, heavy<br />

gauge steel construction finished<br />

with light gray paint. Front and rear<br />

covers shall be removable to provide<br />

access to the terminal compartment.<br />

Terminals shall be fully sized<br />

to carry the transformer full load current<br />

and shall be arranged to accept<br />

required UL-Listed cable connectors.<br />

Units installed outdoors shall have a<br />

UL-Listed type 3R outdoor enclosure,<br />

or shall be UL Listed with optional<br />

weathershields installed. Standard<br />

voltage ratings shall be supplied with<br />

NEMA standard taps for the high-voltage<br />

windings. Unless specified otherwise,<br />

average sound levels (150°C rise) shall<br />

meet the NEMA ST20 standards.<br />

Each transformer shall have a securely<br />

attached nameplate providing complete<br />

electrical ratings, wiring diagram, tap<br />

connections, and catalog number, as<br />

applicable.<br />

K-Factor Rated for Non-Linear Loads<br />

Siemens offers transformer designs<br />

which meet K-Factor ratings. K-Factor<br />

is a ratio between the additional losses<br />

due to harmonics and the eddy losses<br />

at 60Hz. It is used to specify transformers<br />

for non-linear loads. Note that<br />

K-Factor transformers do not eliminate<br />

harmonic distortion; they withstand the<br />

non-linear load condition without overheating.<br />

K-Factor Features<br />

n Designed to ANSI and NEMA<br />

Standards<br />

n UL K-Factor Listed per UL 1561<br />

n K-Factor Rating Designed to IEEE<br />

c57.110<br />

n Aluminum Wound Coils<br />

n Core, Conductors designed for<br />

Harmonics and Eddy Currents 150°C<br />

n Rise, 220°C Insulation<br />

n Electrostatic Shield to Attenuate Line<br />

Transients<br />

n 200% Neutral Bar (2X Phase current)<br />

n NEMA 3R Enclosure standard for D16<br />

catalog numbers<br />

Transformers shall be designed, manufactured,<br />

and tested in accordance with<br />

ANSI, NEMA and IEEE Standards and<br />

shall be UL Listed. The self-cooled kVA<br />

rating shall be suitable for 30°C average,<br />

40°C maximum ambient temperature.<br />

Non-Linear rated transformers shall be<br />

suitable for nonsinusoidal loads and<br />

harmonic distortion as indicated in IEEE<br />

C57.110, and shall be designed with the<br />

following K-Factor rating (choose one):<br />

n K4 for 50% Non-Linear load<br />

n K13 for 100% Non-Linear load<br />

n K20 for 150% Non-Linear load<br />

n K30 for 200% Non-Linear load<br />

Non-Linear rated transformers shall be<br />

UL Listed and shall bear the UL marking<br />

on the nameplate along with the specified<br />

K-Factor rating. Non-Linear rated<br />

transformers shall include the following<br />

design features:<br />

a) Core designed to withstand voltage<br />

distortion and high frequency harmonic<br />

currents. Magnetic flux density<br />

designed to reduce eddy currents and<br />

prevent saturation or overheating of<br />

the core<br />

b) Primary and secondary coils designed<br />

to minimize stray losses, skin effect<br />

losses, and excessive heating from<br />

harmonic currents. Coils shall not<br />

exceed the specified winding temperature<br />

rise, the corresponding hot<br />

spot temperature rating, or the 220°C<br />

insulation rating while carrying the<br />

specified Non-Linear load.<br />

c) Neutral bus sized for 200% of rated<br />

current to withstand circulating currents<br />

and triplen harmonics.<br />

d) An Electrostatic Shield between the<br />

primary and secondary winding and<br />

grounded to a common point within<br />

the transformer enclosure. When<br />

properly grounded, the shield shall<br />

provide noise isolation and attenuate<br />

common mode and transverse mode<br />

noise transients under normal loading<br />

conditions.<br />

e) The design and materials used shall<br />

enable the transformers to comply<br />

with NEMA TP1 efficiency standards.<br />

Options<br />

n Special K-Factor ratings<br />

n Special voltage ratings<br />

n NEMA 3R provided for Series J<br />

Single-Phase with Drip Shield (DS)<br />

n 80° or 115°C temperature rise<br />

n Low noise designs<br />

n Copper windings<br />

n Drip Shields (when not provided as<br />

standard – see chart on page 8-8)<br />

n Wall mounting brackets (15–75 kVA)<br />

(standard in most cases)<br />

n NEMA Premium ® Efficiencies<br />

available only until January 1st, 2016<br />

on 3-Phase but will continue to be<br />

available on Single-Phase<br />

a Temp rise and insulation system values shown are typical.<br />

Variation in these values may exist depending on size,<br />

design and series, but all will comply with the requirements<br />

of UL506 and UL1561.<br />

8-4<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Distribution Dry Type Transformers<br />

Overview of Transformer Offerings<br />

Revised on 04/17/17<br />

Selection<br />

Sentron Power Centers<br />

Harmonic Mitigating Transformers<br />

Buck-Boost Transformers<br />

Single Phase Transformers<br />

Siemens offers single phase transformers<br />

from 0.25 kVA to 167 kVA with<br />

aluminum windings. Common optional<br />

modifiers include Low Temperature<br />

Rise, Electrostatic Shield, Copper<br />

Windings, Wall Mounting Brackets and<br />

Drip Shields. See Page 8-10 for common<br />

single-phase transformer offerings.<br />

Three Phase Transformers<br />

Siemens offers three phase transformers<br />

from 3 kVA through 1000kVA<br />

with aluminum windings. Common<br />

optional modifiers include K factor, Low<br />

Temperature Rise, Electrostatic Shield,<br />

Copper Windings, Low Noise, Wall<br />

Mounting Brackets, and Drip Shields.<br />

All three phase dry-type ventilated<br />

transformers will be manufactured to<br />

DOE 2016 efficiency standards after<br />

January 1, 2016. See page 8-12 for<br />

common three-phase transformer<br />

offerings.<br />

Motor Drive Isolation Transformers<br />

Siemens Drive Isolation Transformers<br />

are designed to meet the rugged<br />

demands of AC and DC variable speed<br />

drives and to provide circuit isolation<br />

from SCR’s. The separate primary and<br />

secondary windings provide isolation<br />

between the incoming line and the load,<br />

minimizing line disturbances, feedback<br />

and transients caused by SCR firing.<br />

Common optional modifiers include low<br />

temperature rise, electrostatic shields,<br />

copper windings, thermal switches, wall<br />

mounting brackets and drip shields. See<br />

page 8-15 for more details.<br />

Sentron Power Centers<br />

Siemens Sentron Power Center is a<br />

pre-wired combination of a primary<br />

breaker disconnect, dry type shielded<br />

transformer, secondary breaker disconnect<br />

and a secondary power panel all<br />

in one convenient package. You save<br />

time, space and money by not having<br />

to individually assemble, mount and<br />

wire these components. Simply add the<br />

branch breakers and you’re ready to go.<br />

Both plug-on and bolt-on breaker panels<br />

are available. All Sentron Power Centers<br />

are UL-3R listed for indoor and outdoor<br />

use. See page 8-17 for more details.<br />

Harmonic Mitigating Transformers<br />

The Sentron Harmonic Mitigating<br />

Transformers (HMTs) are designed to<br />

meet the needs of modern power<br />

distribution systems that contain a large<br />

percentage of non-linear equipment<br />

that produces harmonics. The Sentron<br />

HMTs are specially designed to operate<br />

under high non-linear load conditions<br />

and have the additional benefit of<br />

improving the overall power system<br />

reliability. Siemens Sentron Harmonic<br />

Mitigating Transformers are only available<br />

in three-phase with either one or<br />

two secondaries (outputs). See page 8-20<br />

for more details. DOE 2016 efficiency<br />

standards apply after January 1, 2016.<br />

Buck-Boost Transformers<br />

The Buck-Boost Transformer has four<br />

separate windings; two windings in<br />

the primary and two windings in the<br />

secondary. It can be used as either<br />

an insulating transformer or autotransformer.<br />

As an autotransformer, the unit<br />

can be corrected to Buck (decrease)<br />

or Boost (increase) a supply voltage.<br />

Since autotransformers may transmit<br />

line disturbances directly, they may be<br />

prohibited in some areas by local building<br />

codes. As insulating transformers,<br />

these units can accommodate a high<br />

voltage of 120, 240, or 480 volts. For<br />

units with two 12 volt secondaries, two<br />

16 volt secondaries, or two 24 volt secondaries,<br />

the output can be wired for<br />

either secondary voltage, or for 3-wire<br />

secondary. The unit is rated (kVA) as<br />

any conventional unit. See Page 8-23 for<br />

more details.<br />

8 TRANSFORMERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 8-5


Distribution Dry Type Transformers<br />

Catalog Number Coding System for Transformers<br />

Revised on 04/17/17<br />

Selection<br />

(The first five options are dedicated to Basic Rating Information<br />

Basic Rating Information and are the beginning of all Transformer part numbers)<br />

Secondary<br />

Voltage Suffix Taps Suffix<br />

Primary and Secondary Primary Voltage Configuration Suffix 240/1Ph 120V 1 None N<br />

terminal lugs are<br />

240x120 V 1Ph A 240 2 2-5% FCBN R<br />

included on certain<br />

ventilated transformers.<br />

208 V 1Ph or 3Ph Delta B 208Y/120 3 2-5% (1 FCAN, 1 FCBN) S<br />

See chart on page 8-8 240 V 1Ph or 3Ph Delta C 480 4 4-2.5% (2 FCAN, 2 FCBN) T<br />

for lug information<br />

480x240 V 1Ph D 480Y/277 5 2-2.5% FCBN U<br />

277 V 1Ph E 380Y/219 6 4-2.5% FCBN X<br />

480 V 1Ph or 3Ph Delta F 230Y/133 7 6-2.5% (2 FCAN, 4 FCBN) Y<br />

Phase Suffix 600 V 1Ph or 3Ph Delta G 220/1Ph 110V 8 4-3.1% (2 FCAN, 2 FCBN) J<br />

1-Phase 1 190/200/208/220x380 400/416/440 H 400Y/231 9 2-3.5% (1 FCAN, 1 FCBN) K<br />

3-Phase 3 190/208/220/240x380 416/440/480 X 416Y/240 0 3-5% (1 FCAN, 2 FCBN) M<br />

380V Delta secondary is available<br />

by special quote.<br />

Includes center tap on one phase<br />

often referred to as a lighting tap.<br />

Taps are determined by<br />

transformer design and are<br />

not selectable on standard<br />

catalog units.<br />

3 F 3 Y 150 K13 F ES C LN3 Z4 TE TEE TP1 LZ<br />

Basic Rating Information<br />

Optional Modifiers (If applicable, add suffix to part number in this order, from left to right)<br />

8<br />

TRANSFORMERS<br />

kVA<br />

Suffix<br />

0.25 205<br />

0.5 505<br />

0.75 705<br />

1 001<br />

1.5 105<br />

2 002<br />

3 003<br />

5 005<br />

6 006<br />

7.5 007<br />

9 009<br />

10 010<br />

15 015<br />

25 025<br />

30 030<br />

37.5 037<br />

45 045<br />

50 050<br />

75 075<br />

100 100<br />

112.5 112<br />

150 150<br />

167 167<br />

225 225<br />

300 300<br />

500 500<br />

750 750<br />

1000 000<br />

(To create a Transformer part number, add applicable suffixes after<br />

Optional Modifiers Basic Rating Information in the order shown here and on next page)<br />

Modifier Suffix Description<br />

K4<br />

K-Factor<br />

K13<br />

K-Factor of 1 is standard for all and is not shown as part of part number.<br />

Addition of K-Factor options 4-through 30 include Electrostatic Shield (ES)<br />

K20 option and 200% neutral<br />

K30<br />

150C temperature rise with 220 insulation class is standard, no suffix code is needed<br />

Low<br />

Temperature<br />

B B=80C (80° C temp rise, can tolerate 30% continuous overload) <br />

Rise<br />

F F=115C (115° C temp rise, can tolerate 15% continuous overload) <br />

G G=130C<br />

Electrostatic shield (full width copper foil) for added noise attenuation and reduction of<br />

high frequency disturbances.<br />

Electrostatic<br />

Shield<br />

ES<br />

ES is standard with K4-K30 options, so it is not included in catalog number with<br />

K4-K30 options. Common mode attenuation is either 50dB (Series J) or 60dB<br />

(Series H). Transverse mode attenuation is either 10dB (Series H) or 30dB (Series J).<br />

ES2 ES2=dual (only applicable to HD1). Series H only.<br />

Copper Wound C C=Copper Windings. Aluminum windings are standard, no suffix code needed.<br />

LN3 LN3=3dB below NEMA ST20<br />

Low Noise LN5 LN5=5dB below NEMA ST20<br />

LN() ()=dB below NEMA ST20. Contact sales office for levels other than LN3 & LN5.<br />

Seismic rated Z4<br />

See chart on page 8-8 for available seismic ratings, not part of catalog<br />

number when standard. Not used after DOE 2016 is introduced. Shown for<br />

legacy products only.<br />

Totally Enclosed<br />

(Non-Ventilated)<br />

Totally Enclosed<br />

Encapsulated<br />

Energy<br />

Efficient e<br />

TE<br />

TEE<br />

D16<br />

TE for Series H is NEMA 4 as a standard. TE for Series J is NEMA 3R as a<br />

standard. Other NEMA types available. TE option not available with D16<br />

and TP1.<br />

Same as TE except encapsulated. TEE not available with D16 and TP1.<br />

D16=DOE 2016 standards. DOE 2016 standards will replace TP1 For 3 Phase<br />

Ventilated Dry Type Transformers for 15 kVA-1000kVA starting Jan. 1, 2016<br />

TP1 Still valid for single phase and all non ventilated transformers after Jan. 1, 2016<br />

Frequency LZ Standard is 60 Hertz. LZ option is 50/60 Hz. Not available with TP1 and D16.<br />

Note 1: If the catalog number will not completely describe the product, it will be identified<br />

as SPC-- - -kVA-XFMR.<br />

Note 2: “JST” suffix has been removed. Standard units are in stock for immediate<br />

shipment in many cases. Contact customer support.<br />

With continuous overloads these units will be operating at 150 C rise designs.<br />

e All D16 catalog numbers include NEMA 3R enclosures as standard unless other options<br />

chosen change or remove the enclosure.<br />

8-6<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Distribution Dry Type Transformers<br />

Catalog Number Coding System for Transformers<br />

Selection<br />

Modifier Suffix Description<br />

Harmonic<br />

Mitigation<br />

“NEMA<br />

Premium”<br />

Phase Shift<br />

for HD1<br />

Optional Modifiers (continued)<br />

HD1 for DOE 2016 standard 3 phase dry type ventilated transformers only. Series H only.<br />

HD1<br />

NP<br />

HD1=1 secondary/single output<br />

Surpasses NEMA-TP1 (Combine NP with available combined options as shown:<br />

“TP1…NP”, “HM1…NP”, “HM2…NP“). DOE 2016 standards surpass NP. NP not<br />

available after January 1 , 2016 for DOE 2016 3 phase ventilated dry type transformers<br />

(15kVA-1000kVA). NP 1-phase will continue to be available after this date.<br />

Only to be used with suffix code HD1<br />

0 0 degree lagging<br />

30 30 degree lagging<br />

Optional Product Offerings<br />

1. For non-standard or non-cataloged<br />

voltages or non-cataloged primary taps<br />

refer to sales office.<br />

2. Non-standard application, 50/60 Hz,<br />

special impedance, voltage, etc.-<br />

consult sales office.<br />

3. Auto transformers (A)- see page 8-11.<br />

4. Non-standard paint color-contact sales<br />

office.<br />

5. Harmonic mitigating transformers-see<br />

page 8-15.<br />

6. Transformer and panel combinationssee<br />

page 8-13 & 8-14.<br />

Optional Modifiers—continued (If applicable, add suffix to part number in this order, from left to right)<br />

HD1 NP 30 TS7 TV TB SS SSN4X I3 CC W VG DS<br />

Modifier Suffix Description<br />

Thermal<br />

Switches<br />

TVSS/SPD<br />

Terminal Block<br />

Stainless Steel<br />

Enclosure<br />

Enclosure Types<br />

Special<br />

Impedance<br />

Optional Modifiers (continued)<br />

Typical Thermal Switch is 2.5 A and 250V max, typical installation is one TS per coil with wires<br />

brought to a modular screw terminal block on top of the transformer. Customer must specify NO<br />

or NC contacts. Contact customer support for special requirements.<br />

TS7 ( ) 170C ( ) =no value: 1 switch<br />

TS8 ( ) 180C ( ) = 2: 2 switches<br />

TS0 ( ) 200C ( ) = 6: 6 switches<br />

Filter Capacitors Secondary Side with Surge Suppression. Available for Series H only.<br />

TV<br />

Must specify 100kA or 200kA surge rating.<br />

Contact customer support for standard terminal block availability.<br />

TB<br />

If special terminating requirements please advise<br />

SS 304 stainless (NEMA 3R if no NEMA type qualifier is specified)<br />

SS316 316 stainless (NEMA 3R if no NEMA type qualifier is specified)<br />

304 stainless is standard. Stainless steel 316 available with a special quote.<br />

SSN4X Non-Metallic NEMA 4X option not available. <br />

Standard is grey painted steel. 304 is standard for stainless steel option and 316 Stainless steel is<br />

available with a special quote.<br />

N12 NEMA 12 (SSN12 with 304 stainless) 316 available with special quote <br />

N4 NEMA 4 (SSN4 with 304 stainless) 316 available with special quote <br />

The impedance tolerance per ANSI is +/- 7.5% nominal which is the “I” value shown on<br />

Impedance charts. (see SpeedFax Supplement - Addendums H and J)<br />

Contact customer support for special requirements (if max or min or min/max range is required.)<br />

(If no Min or Max is specified - catalog number will NOT include an “I” value)<br />

Ix.x or Ix I2.5 = 2.5% max. or I3 = 3% max. for example. I2.5 to I6.5 are typical values.<br />

IMx.x IM2.5 = 2.5% min. or IM3 = 3% min. for example.<br />

IM2.5I5.5 = 2.5% min. and 5.5% max. impedance range or IM21I5 = 2% min. and 5%<br />

IMx.xIx.x<br />

max. range are examples.<br />

Name plate is displayed on frame bracket. Product may be shipped with or without<br />

CC<br />

enclosure.<br />

W Some DOE 2016 3 Phase Dry Type Ventilated Transformers include Wall Brackets.<br />

See chart on next page for non-DOE availability and DOE 2016 details.<br />

Core and Coil<br />

Assembly<br />

Wall Mounting<br />

Brackets<br />

Vent Guard VG Vent Guard is a Mesh screen to prevent vent opening access.<br />

Drip Shields<br />

(weathershields)<br />

DS <br />

Most DOE 2016 Dry Type Ventilated Transformers include Drip Shields from 15kVA to<br />

1000kVA. See chart on next page for availability. Also see non-DOE availability.<br />

8 TRANSFORMERS<br />

The W and DS codes are not always part of the catalog number.<br />

Only shown as reference when it is not a standard feature of the device.<br />

Not available with D16 or TP1.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 8-7


Distribution Dry Type Transformers<br />

Catalog Number Coding System for Transformers<br />

Revised on 05/31/18<br />

Selection<br />

Seismic Rated:<br />

All others not listed below are not seismic rated<br />

(contact customer support for Wall Mounting Ratings if needed)<br />

Encapsulated Ventilated Non Ventilated<br />

Phase Series J Series J Series H Series J <br />

1 1-25kVA<br />

(Wall Mounted)<br />

S DS =2.00g ; z/h = 1.00 ; I p = 1.5<br />

1-250 kVA<br />

(Floor Mounted)<br />

S DS =2.00g ; z/h = 1.00 ; I p = 1.5<br />

15-167kVA<br />

(Floor Mounted Only)<br />

S DS =2.00g ; z/h = 1.00 ; I p = 1.5<br />

1-250kVA<br />

(Floor Mounted Only)<br />

S DS =2.00g ; z/h = 1.00 ; I p = 1.5<br />

3 3-75kVA<br />

(Floor Mounted)<br />

S DS =2.00g ; z/h = 1.00 ; I p = 1.5<br />

1-1000kVA<br />

(Floor Mounted)<br />

S DS =2.00g ; z/h = 1.00 ; I p = 1.5<br />

15-750kVA<br />

(Floor Mounted Only) <br />

S DS =2.00g ; z/h = 1.00 ; I p = 1.5<br />

1-500kVA<br />

(Floor Mounted Only)<br />

S DS =2.00g ; z/h = 1.00 ; I p = 1.5<br />

DOE 2016 3 Phase Ventilated<br />

3 NA 1-1000kVA<br />

(Floor Mounted)<br />

Seismic labels are standard up to 750kVA with 150C temperature rise.<br />

Series J Results are filed with OSHPD per OSP-0109-10.<br />

Series H results are filed with OSHPD per OSP-0136-10.<br />

15-750kVA<br />

(Floor Mounted Only)<br />

Seismic Qualified according to:<br />

• International Building Code (IBC) 2012<br />

• American Society of Civil Engineers (ASCE) 7-10<br />

NA<br />

8<br />

TRANSFORMERS<br />

Wall Mounting Brackets and Drip Shields<br />

1 Phase Dry Type Wall Brackets/Drip Shields<br />

Wall Mounting Brackets (W) Drip Shields (DS)<br />

kVA<br />

Series J Series H Series J Series H<br />

0.25-25 Encapsulated Wall Mount only NA NA NA<br />

All items below are Ventilated<br />

15, 25 Optional** Standard Standard Standard<br />

37.5 Optional** See Note 1 Standard Standard<br />

50 Optional** See Note 1 Standard Standard<br />

75 NA See Note 1 Standard Standard<br />

100-500 NA Standard Standard<br />

3 Phase Dry Type Ventilated DOE 2016 Wall Brackets/Drip Shields<br />

Wall Mounting Brackets (W) Drip Shields (DS)<br />

kVA<br />

Series J Series H Series J Series H<br />

15, 30 Optional** Standard Standard Standard<br />

45 Optional** See Note 1 Standard Standard<br />

75 See Note 2 See Note 1 Standard Standard<br />

112.5-1000 N/A See Note 1 Standard Standard<br />

3 Phase Dry Type Encapsulated<br />

Wall Mounting Brackets (W) Drip Shields (DS)<br />

kVA<br />

Series J Series H Series J Series H<br />

3-15 Standard Standard N/A N/A<br />

**For DOE 2016 and 1-Phase ventilated, cost of transformer will not include wall brackets.<br />

Wall brackets will be an additional charge.<br />

Standard Terminal Lug Offerings <br />

(Primary and Secondary) for Ventilated Transformers (150 Degree Rise - Series J only - Without a K rating)<br />

1-Phase<br />

3-Phase<br />

kVA 120/240V 208V 480V 600V kVA 120/240V 208V 480V 600V<br />

0-15 Contact customer support 0-15 Contact customer support<br />

15 #2/0-6 #14-2 #14-2 #14-2 15 #14-2 #14-2 #14-2 #14-2<br />

25 250MCM-6 250MCM-6 #14-2 #14-2 30 #2/0-6 #2/0-6 #14-2 #14-2<br />

37.5 350MCM-6 350MCM-6 #14-2 #14-2 45 250MCM-6 250MCM-6 #14-2 #14-2<br />

50 600MCM-2 600MCM-2 #2/0-6 #2/0-6 75 600MCM-2 350MCM-6 #2/0-6 #2/0-6<br />

>50 Contact customer support >75 Contact customer support<br />

Values listed above are for standard configurations.<br />

There may be slight variations depending on requirements.<br />

Contact Customer Support for special requirements<br />

For Series H, see chart in Series H Addendum - Page H-16. Lug sizes are not available except on cutsheets.<br />

Contact Customer Support for special requirements.<br />

1. Standard with DH1 and DH2 enclosures.<br />

For DH3 enclosure, Series H transformers<br />

1000 lbs or less can be wall mounted with<br />

kit p/n TWB75H. The DH3 designation is<br />

found on the lower left corner of the Front<br />

View Outline on the transformer drawing.<br />

2. Optional except with copper windings or<br />

options B, K13, K20. See table page 8-27.<br />

8-8<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Distribution Dry Type Transformers<br />

Single Phase<br />

Revised on 05/31/18<br />

Selection<br />

kVA<br />

Catalog<br />

Number Taps a Temperature<br />

Rise<br />

Insulation<br />

Mounting<br />

Type bef<br />

Drip Shield<br />

Provided c<br />

Enclosure<br />

Style – Type d<br />

Optional<br />

Modifications<br />

208 Volts Primary, 120/240 Volts Secondary<br />

1. 1B1N001 N 95° C 130° C Wall No Encapsulated – NEMA 3R 1, 2, 4<br />

2 1B1N002 N 135° C 180° C Wall No 1, 2, 4<br />

3 1B1N003 N 135° C 180° C Wall No 1, 2, 4<br />

5 1B1N005 N 135° C 180° C Wall No 1, 2, 4<br />

7.5 1B1N007 N 135° C 180° C Wall No 1, 2, 4<br />

010 1B1N010 N 135° C 180° C Wall No 1, 2, 4<br />

015 1B1N015 N 135° C 180° C Wall No 1, 2, 4<br />

15 1B1Y015TP1 Y 150° C 220° C Floor & Wall Yes Ventilated – NEMA 3R 1, 2, 3<br />

025 1B1Y025TP1 Y 150° C 220° C Floor & Wall Yes 1, 2, 3<br />

037.5 1B1Y037TP1 Y 150° C 220° C Floor & Wall Yes 1, 2, 3<br />

050 1B1S050TP1 Y g S 150° C 220° C Floor & Wall Yes 1, 2, 3<br />

075 1B1S075TP1 Y g S 150° C 220° C Floor Yes Ventilated – NEMA 3R 1, 2, 3<br />

0100 1B1S100TP1 Y g S 150° C 220° C Floor Yes 1, 2, 3<br />

0167 1B1S167TP1 Y g S 150° C 220° C Floor Yes 1, 2, 3<br />

240 @ 480 Volts Primary, 120/240 Volts Secondary<br />

.25 1D1N205 N 95° C 130° C Wall No Encapsulated – NEMA 3R 1, 2, 4<br />

.50 1D1N505 N 95° C 130° C Wall No 1, 2, 4<br />

.75 1D1N705 N 95° C 130° C Wall No 1, 2, 4<br />

1.0 1D1N001 N 95° C 130° C Wall No 1, 2, 4<br />

1.5 1D1N105 N 135° C 180° C Wall No Encapsulated – NEMA 3R 1, 2, 4<br />

2.0 1D1N002 N 135° C 180° C Wall No 1, 2, 4<br />

3.0 1D1N003 N 135° C 180° C Wall No 1, 2, 4<br />

5.0 1D1N005 N 135° C 180° C Wall No 1, 2, 4<br />

7.5 1D1N007 N 135° C 180° C Wall No 1, 2, 4<br />

10.0 1D1N010 N 135° C 180° C Wall No 1, 2, 4<br />

15 1D1N015 N 135° C 180° C Wall No 1, 2, 4<br />

15 1D1Y015TP1 Y 150° C 220° C Floor & Wall Yes Ventilated – NEMA 3R 1, 2, 3<br />

25 1D1Y025TP1 Y 150° C 220° C Floor & Wall Yes 1, 2, 3<br />

37.5 1D1Y037TP1 Y 150° C 220° C Floor & Wall Yes 1, 2, 3<br />

50 1D1Y050TP1 Y 150° C 220° C Floor & Wall Yes 1, 2, 3<br />

75 1D1Y075TP1 Y 150° C 220° C Floor & Wall Yes Ventilated – NEMA 3R 1, 2, 3<br />

100 1D1Y100TP1 Y 150° C 220° C Floor Yes 1, 2, 3<br />

167 1D1Y167TP1 Y 150° C 220° C Floor Yes 1, 2, 3<br />

277 Volts Primary, 120/240 Volts Secondary<br />

3 1E1U003 U 135° C 180° C Wall No Encapsulated – NEMA 3R 1, 2, 4<br />

5 1E1U005 U 135° C 180° C Wall No 1, 2, 4<br />

7.5 1E1U007 U 135° C 180° C Wall No 1, 2, 4<br />

10 1E1U010 U 135° C 180° C Wall No 1, 2, 4<br />

15 1E1U015 U 135° C 180° C Wall No 1, 2, 4<br />

25 1E1U025 U 135° C 180° C Wall No 1, 2, 4<br />

480 Volts Primary, 120/240 Volts Secondary<br />

3 1F1R003 R 135° C 180° C Wall No Encapsulated – NEMA 3R 1, 2, 4<br />

5 1F1R005 R 135° C 180° C Wall No 1, 2, 4<br />

7.5 1F1R007 R 135° C 180° C Wall No 1, 2, 4<br />

10 1F1R010 R 135° C 180° C Wall No 1, 2, 4<br />

15 1F1R015 R 135° C 180° C Wall No 1, 2, 4<br />

25 1F1R025 R 135° C 180° C Wall No 1, 2, 4<br />

Optional Modifications Table (Contact Sales office for List Price)<br />

Optional (commonly used)<br />

Catalog<br />

Modifications<br />

Suffix Code<br />

1a. 115° C Rise F<br />

1b. 80° C Rise B<br />

2. Electrostatic Shield ES<br />

3. Copper Windings C<br />

4. Wall Mounting Brackets1 W<br />

5. Drip Shields DS<br />

Taps<br />

Description<br />

Designation<br />

None<br />

N<br />

2–5% FCBN R<br />

2–5% (1 FCAN, 1 FCBN) S<br />

2–2.5% FCBN U<br />

6–2.5% (2 FCAN, 4 FCBN) Y<br />

8 TRANSFORMERS<br />

a Actual taps may vary based on volts/turn ratio.<br />

b Wall designations for units having standard features.<br />

c For outdoor application. Ventilated transformers<br />

requiring drip shields/weathershields are UL listed for<br />

outdoor use. All are NEMA 3R rated.<br />

d Encapsulated transformers are UL listed for indoor/<br />

outdoor use. NEMA 3R rated.<br />

e Items marked floor and wall can be wall mounted with<br />

optional wall bracket.<br />

f See table on page 8-8 for available kits.<br />

g Series H Tap Standard.<br />

h Series J Tap Standard.<br />

Product Category XFMR<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 8-9


Distribution Dry Type Transformers<br />

Single Phase<br />

Revised on 12/31/19<br />

Selection<br />

kVA<br />

Catalog<br />

Number Taps a Temperature<br />

Rise<br />

600 Volts Primary, 120/240 Volts Secondary<br />

Insulation<br />

Mounting<br />

Type be<br />

Drip Shield<br />

Provided c<br />

Enclosure<br />

Style d<br />

Optional<br />

Modifications<br />

3 1G1R003 R 135° C 180° C Wall No Encapsulated – NEMA 3R 1, 2, 4<br />

5 1G1R005 R 135° C 180° C Wall No 1, 2, 4<br />

7.5 1G1R007 R 135° C 180° C Wall No 1, 2, 4<br />

10 1G1R010 R 135° C 180° C Wall No 1, 2, 4<br />

15 1G1R015 R 135° C 180° C Wall No 1, 2, 4<br />

25 1G1R025 R 135° C 180° C Wall No 1, 2, 4<br />

25 1G1T025TP1 Y g T h 150° C 220° C Floor & Wall Yes Ventilated – NEMA 3R 1, 2, 3<br />

37.5 1G1T037TP1 Y g T h 150° C 220° C Floor & Wall Yes 1, 2, 3<br />

50 1G1T050TP1 Y g T h 150° C 220° C Floor & Wall Yes 1, 2, 3<br />

75 1G1T075TP1 Y g T h 150° C 220° C Floor Yes Ventilated – NEMA 3R 1, 2, 3<br />

100 1G1T100TP1 Y g T h 150° C 220° C Floor Yes 1, 2, 3<br />

167 1G1T167TP1 Y g T h 150° C 220° C Floor Yes 1, 2, 3<br />

Overseas Model 190/200/208/220 x 380/400/416/440 Volts Primary, 120/240 Volts Secondary—1Ø, 50/60 Hz<br />

1 1H1N001 N 95° C 130° C Wall No Encapsulated – NEMA 3R 2, 3<br />

2 1H1N002 i N 135° C 180° C Wall No 2, 3<br />

3 1H1N003 i N 135° C 180° C Wall No 2, 3<br />

5 1H1N005 i N 135° C 180° C Wall No 2, 3<br />

7.5 1H1N007 N 135° C 180° C Wall No 2, 3<br />

10 1H1N010 N 135° C 180° C Wall No 2, 3<br />

15 1H1N015 N 135° C 180° C Wall No 2, 3<br />

25 1H1N025 N 135° C 180° C Wall No 2, 3<br />

Overseas Model 190/208/220/240 x 380/416/440/480 Volts Primary, 120/240 Volts Secondary—1Ø, 50/60 Hz<br />

1 1X1N001 N 95° C 130° C Wall No Encapsulated – NEMA 3R 2, 3<br />

2 1X1N002 i N 135° C 180° C Wall No 2, 3<br />

3 1X1N003 i N 135° C 180° C Wall No 2, 3<br />

5 1X1N005 i N 135° C 180° C Wall No 2, 3<br />

7.5 1X1N007 N 135° C 180° C Wall No 2, 3<br />

10 1X1N010 N 135° C 180° C Wall No 2, 3<br />

15 1X1N015 N 135° C 180° C Wall No 2, 3<br />

25 1X1N025 N 135° C 180° C Wall No 2, 3<br />

Overseas Model 190/200/208/220 x 380/400/416/440 Volts Primary, 110/220 Volts Secondary—1Ø, 50/60 Hz<br />

1 1H8N001 N 95° C 130° C Wall No Encapsulated – NEMA 3R 2, 3<br />

2 1H8N002 i N 135° C 180° C Wall No 2, 3<br />

3 1H8N003 i N 135° C 180° C Wall No 2, 3<br />

5 1H8N005 i N 135° C 180° C Wall No 2, 3<br />

7.5 1H8N007 N 135° C 180° C Wall No 2, 3<br />

8<br />

TRANSFORMERS<br />

Optional Modifications Table (Contact Sales office for List Price)<br />

Optional (commonly used)<br />

Modifications<br />

1a. 115° C Rise F<br />

1b. 80° C Rise B<br />

2. Electrostatic Shield ES<br />

3. Copper Windings C<br />

4. Wall Mounting Brackets1 W<br />

5. Drip Shields DS<br />

Catalog<br />

Suffix Code<br />

Taps<br />

Description<br />

None<br />

N<br />

2–5% FCBN R<br />

2–5% (1 FCAN, 1 FCBN) S<br />

2–2.5% FCBN U<br />

6–2.5% (2 FCAN, 4 FCBN) Y<br />

Designation<br />

a Actual taps may vary based on volts/turn ratio.<br />

b Wall designations for units having standard features.<br />

c For outdoor application. Ventilated transformers<br />

requiring drip shields/weathershields are UL listed for<br />

outdoor use. All are NEMA 3R rated.<br />

d Encapsulated transformers are UL listed for indoor/<br />

outdoor use. NEMA 3R rated.<br />

e Items marked floor and wall can be wall mounted with<br />

optional wall bracket.<br />

f See table on page 8-8 for available kits.<br />

g Series H Tap Standard.<br />

h Series J Tap Standard.<br />

i Available with CE mark.<br />

8-10<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category XFMR


Distribution Dry Type Transformers<br />

Three Phase<br />

Revised on 05/31/18<br />

Selection<br />

kVA<br />

Catalog<br />

Number Taps a Temperature<br />

Rise<br />

Insulation<br />

Mounting<br />

Type beh<br />

Drip Shield<br />

Provided c<br />

Enclosure<br />

Style d<br />

Optional<br />

Modifications<br />

480 Volts ∆ Primary, 240 Volts ∆ Secondary With 120 Volt Tap On B Phase <br />

15 3F1Y015D16 Y 150° C 220° C Floor & Wall Yes Ventilated – NEMA 3R 1, 2, 3, 4<br />

30 3F1Y030D16 Y 150° C 220° C Floor & Wall Yes 1, 2, 3, 4<br />

45 3F1Y045D16 Y 150° C 220° C Floor & Wall Yes 1, 2, 3, 4<br />

75 3F1Y075D16 Y 150° C 220° C Floor Yes Ventilated – NEMA 3R 1, 2, 3, 4<br />

112.5 3F1Y112D16 Y 150° C 220° C Floor Yes 1, 2, 3, 4<br />

150 3F1Y150D16 Y 150° C 220° C Floor Yes 1, 2, 3<br />

225 3F1Y225D16 Y 150° C 220° C Floor Yes 1, 2, 3<br />

300 3F1Y300D16 Y 150° C 220° C Floor Yes 1, 2, 3<br />

500 3F1T500D16 Y j , T 150° C 220° C Floor Yes 1, 2, 3<br />

750 3F1T750D16 Y j , T 150° C 220° C Floor Yes 1, 2, 3<br />

480 Volts ∆ Primary, 240 Volts ∆ Secondary<br />

3 3F2R003 f R 135° C 180° C Wall No Encapsulated – NEMA 3R 1, 2, 3<br />

6 3F2R006 f R 135° C 180° C Wall No 1, 2, 3<br />

9 3F2R009 f R 135° C 180° C Wall No 1, 2, 3<br />

15 3F2R015 f R 135° C 180° C Wall No 1, 2, 3<br />

480 Volts ∆ Primary, 208Y/120 Volts Secondary<br />

3 3F3R003 R 135° C 180° C Wall No Encapsulated – NEMA 3R 1, 2, 3<br />

6 3F3R006 R 135° C 180° C Wall No 1, 2, 3<br />

9 3F3R009 R 135° C 180° C Wall No 1, 2, 3<br />

15 3F3R015 R 135° C 180° C Wall No 1, 2, 3<br />

15 3F3Y015D16 Y 150° C 220° C Floor & Wall Yes Ventilated – NEMA 3R 1, 2, 3, 4, 6<br />

30 3F3Y030D16 Y 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 6<br />

45 3F3Y045D16 Y 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 6<br />

75 3F3Y075D16 Y 150° C 220° C Floor & Wall Yes Ventilated – NEMA 3R 1, 2, 3, 4, 6<br />

112.5 3F3Y112D16 Y 150° C 220° C Floor Yes 1, 2, 3, 6<br />

150 3F3Y150D16 Y 150° C 220° C Floor Yes 1, 2, 3, 6<br />

225 3F3Y225D16 Y 150° C 220° C Floor Yes 1, 2, 3, 6<br />

300 3F3Y300D16 Y 150° C 220° C Floor Yes 1, 2, 3, 6<br />

500 3F3T500D16 Y j , T 150° C 220° C Floor Yes 1, 2, 3, 6<br />

750 3F3T750D16 Y j , T 150° C 220° C Floor Yes 1, 2, 3, 6<br />

1000 3F3T000D16 T 150° C 220° C Floor Yes 1, 2, 3, 6<br />

kVA<br />

Catalog<br />

Temperature<br />

Number Taps a Rise<br />

Optional Modifications Table (Contact Sales office for List Price)<br />

Optional (commonly used)<br />

Catalog<br />

Modifications<br />

Suffix Code<br />

1a. 115°C Rise F<br />

1b. 80°C Rise B<br />

2. Electrostatic Shield ES<br />

3. Copper Windings C<br />

4. Wall Mounting Brackets1 W<br />

6. Low noise — XdB below std. LNX<br />

Insulation<br />

Mounting<br />

Type<br />

Drip Shield<br />

Required<br />

Taps<br />

Description<br />

Designation<br />

None<br />

N<br />

2–5% FCBN R<br />

2–5% (1 FCAN, 1 FCBN) S<br />

2–2.5% FCBN U<br />

6–2.5% (2 FCAN, 4 FCBN) Y<br />

Optional<br />

Modifications<br />

Avg. Sound<br />

Level<br />

Totally Enclosed Transformers, Indoor/Outdoor Use 480 Volts ∆ Primary, 208Y/120 Volts Secondary g<br />

15 3F3Y015TE Y 150° C 220° C Floor No 1, 2, 3 50dB<br />

30 3F3Y030TE Y 150° C 220° C Floor No 1, 2, 3 50dB<br />

45 3F3Y045TE Y 150° C 220° C Floor No 1, 2, 3 50dB<br />

75 3F3Y075TE Y 150° C 220° C Floor No 1, 2, 3 55dB<br />

112.5 3F3Y112TE Y 150° C 220° C Floor No 1, 2, 3 55dB<br />

150 3F3Y150TE Y 150° C 220° C Floor No 1, 2, 3 55dB1<br />

225 3F3Y225TE Y 150° C 220° C Floor No 1, 2, 3 57dB1<br />

300 3F3Y300TE Y 150° C 220° C Floor No 1a, 2, 3 57dB1<br />

480 Volts ∆ Primary, 240 Volts ∆ Secondary with 120V Lighting Tap on B Phase g<br />

15 3F1Y015TE Y 150° C 220° C Floor No 1, 2, 3 50dB<br />

30 3F1Y030TE Y 150° C 220° C Floor No 1, 2, 3 50dB<br />

45 3F1Y045TE Y 150° C 220° C Floor No 1, 2, 3 50dB<br />

75 3F1Y075TE Y 150° C 220° C Floor No 1, 2, 3 55dB<br />

112.5 3F1Y112TE Y 150° C 220° C Floor No 1, 2, 3 55dB<br />

150 3F1Y150TE Y 150° C 220° C Floor No 1, 2, 3 55dB<br />

225 3F1Y225TE Y 150° C 220° C Floor No 1, 2, 3 57dB<br />

300 3F1Y300TE Y 150° C 220° C Floor No 1a, 2, 3 57dB<br />

8 TRANSFORMERS<br />

a Actual taps may vary based on volts/turn ratio.<br />

b Wall designations for units having standard features.<br />

c Ventilated transformers with drip shields are UL listed<br />

for outdoor use. NEMA 3R rated.<br />

d Encapsulated transformers are UL listed for indoor/<br />

outdoor use. NEMA 3R rated.<br />

e See table on page 8-8 for available kits.<br />

f 240 volt secondary (3F2) is available in 3-phase 3 to<br />

15kVA only.<br />

g TE units will have inrush equal to 2 sizes<br />

larger than rated kVA.<br />

h Items marked floor and wall can be wall mounted<br />

with optional wall bracket that may be identified with<br />

“W” suffix on catalog number.<br />

i Wall mounting for 150˚C temperature rise.<br />

j Series H Tap Standard.<br />

k Series J Tap Standard.<br />

Product Category XFMR<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 8-11


Distribution Dry Type Transformers<br />

Three Phase<br />

Revised on 05/15/18<br />

Selection<br />

8<br />

TRANSFORMERS<br />

kVA<br />

Catalog<br />

Temperature<br />

Number Taps a Rise<br />

Optional Modifications Table (Contact Sales office for List Price)<br />

Optional (commonly used)<br />

Catalog<br />

Modifications<br />

Suffix Code<br />

1a. 115°C Rise F<br />

1b. 80°C Rise B<br />

2. Electrostatic Shield ES<br />

3. Copper Windings C<br />

4. Wall Mounting Brackets1 W<br />

6. Low noise — XdB below std. LNX<br />

Insulation<br />

Mounting<br />

Type bfg<br />

Drip Shield<br />

Provided c<br />

Taps<br />

Description<br />

Designation<br />

None<br />

N<br />

2–5% FCBN R<br />

2–5% (1 FCAN, 1 FCBN) S<br />

2–2.5% FCBN U<br />

6–2.5% (2 FCAN, 4 FCBN) Y<br />

Enclosed<br />

Type d<br />

Optional<br />

Modifications<br />

480 Volts ∆ Primary, 480Y/277 Volts Secondary<br />

15 3F5R015 R 135° C 180° C Wall No Encapsulated – NEMA 3R 1, 2, 3<br />

15 3F5Y015D16 Y 150° C 220° C Floor & Wall Yes Ventilated – NEMA 3R 1, 2, 3, 4, 6<br />

30 3F5Y030D16 Y 150° C 220° C Floor & Wall Yes Ventilated 1, 2, 3, 4, 6<br />

45 3F5Y045D16 Y 150° C 220° C Floor & Wall Yes Ventilated 1, 2, 3, 4, 6<br />

75 3F5Y075D16 Y 150° C 220° C Floor Yes Ventilated – NEMA 3R 1, 2, 3, 6<br />

112.5 3F5Y112D16 Y 150° C 220° C Floor Yes Ventilated 1, 2, 3, 6<br />

150 3F5Y150D16 Y 150° C 220° C Floor Yes Ventilated 1, 2, 3, 6<br />

225 3F5Y225D16 Y 150° C 220° C Floor Yes Ventilated 1, 2, 3, 6<br />

300 3F5Y300D16 Y 150° C 220° C Floor Yes Ventilated 1, 2, 3, 6<br />

500 3F5T500D16 Y , T 150° C 220° C Floor Yes Ventilated 1, 2, 3, 6<br />

3-Phase 480 ∆ — 208Y/120 K-4 (50% Non-Linear Load) e<br />

15 3F3Y015K4D16 Y 150° C 220° C Floor & Wall Yes Ventilated – NEMA 3R 1, 3, 4, 6<br />

30 3F3Y030K4D16 Y 150° C 220° C Floor & Wall Yes Ventilated 1, 3, 4, 6<br />

45 3F3Y045K4D16 Y 150° C 220° C Floor & Wall Yes Ventilated 1, 3, 4, 6<br />

75 3F3Y075K4D16 Y 150° C 220° C Floor Yes Ventilated – NEMA 3R 1, 3, 6<br />

112.5 3F3Y112K4D16 Y 150° C 220° C Floor Yes Ventilated 1, 3, 6<br />

150 3F3Y150K4D16 Y 150° C 220° C Floor Yes Ventilated 1, 3, 6<br />

225 3F3Y225K4D16 Y 150° C 220° C Floor Yes Ventilated 1, 3, 6<br />

300 3F3Y300K4D16 Y 150° C 220° C Floor Yes Ventilated 1, 3, 6<br />

500 3F3T500K4D16 Y , T 150° C 220° C Floor Yes Ventilated 1, 3, 6<br />

3-Phase 480 ∆ — 208Y/120 K-13 (100% Non-Linear Load) e<br />

15 3F3Y015K13D16 Y 150° C 220° C Floor & Wall Yes Ventilated – NEMA 3R 1, 3, 4, 6<br />

30 3F3Y030K13D16 Y 150° C 220° C Floor & Wall Yes Ventilated 1, 3, 4, 6<br />

45 3F3Y045K13D16 Y 150° C 220° C Floor & Wall Yes Ventilated 1, 3, 4, 6<br />

75 3F3Y075K13D16 Y 150° C 220° C Floor Yes Ventilated – NEMA 3R 1, 3, 6<br />

112.5 3F3Y112K13D16 Y 150° C 220° C Floor Yes Ventilated 1, 3, 6<br />

150 3F3Y150K13D16 Y 150° C 220° C Floor Yes Ventilated 1, 3, 6<br />

225 3F3Y225K13D16 Y 150° C 220° C Floor Yes Ventilated 1, 3, 6<br />

300 3F3Y300K13D16 Y 150° C 220° C Floor Yes Ventilated 1, 3, 6<br />

500 3F3T500K13D16 Y , T 150° C 220° C Floor Yes Ventilated 1, 3, 6<br />

3-Phase 480 ∆ — 208Y/120 K-20 (125% Non-Linear Load) e<br />

15 3F3Y015K20D16 Y 150° C 220° C Floor & Wall Yes Ventilated – NEMA 3R 1, 3, 4, 6<br />

30 3F3Y030K20D16 Y 150° C 220° C Floor & Wall Yes Ventilated 1, 3, 4, 6<br />

45 3F3Y045K20D16 Y 150° C 220° C Floor & Wall Yes Ventilated 1, 3, 4, 6<br />

75 3F3Y075K20D16 Y 150° C 220° C Floor Yes Ventilated – NEMA 3R 1, 3, 6<br />

112.5 3F3Y112K20D16 Y 150° C 220° C Floor Yes Ventilated 1, 3, 6<br />

150 3F3Y150K20D16 Y 150° C 220° C Floor Yes Ventilated 1, 3, 6<br />

225 3F3Y225K20D16 Y 150° C 220° C Floor Yes Ventilated 1, 3, 6<br />

300 3F3Y300K20D16 Y 150° C 220° C Floor Yes Ventilated 1, 3, 6<br />

500 3F3T500K20D16 Y , T 150° C 220° C Floor Yes Ventilated 1, 3, 6<br />

3-Phase 480 ∆ — 208Y/120 K-30 (150% Non-Linear Load) e<br />

15 3F3Y015K30D16 Y 150° C 220° C Floor & Wall Yes Ventilated – NEMA 3R 1, 3, 4, 6<br />

30 3F3Y030K30D16 Y 150° C 220° C Floor & Wall Yes Ventilated 1, 3, 4, 6<br />

45 3F3Y045K30D16 Y 150° C 220° C Floor & Wall Yes Ventilated 1, 3, 4, 6<br />

75 3F3Y075K30D16 Y 150° C 220° C Floor Yes Ventilated – NEMA 3R 1, 3, 6<br />

112.5 3F3Y112K30D16 Y 150° C 220° C Floor Yes Ventilated 1, 3, 6<br />

150 3F3Y150K30D16 Y 150° C 220° C Floor Yes Ventilated 1, 3, 6<br />

225 3F3Y225K30D16 Y 150° C 220° C Floor Yes Ventilated 1, 3, 6<br />

300 3F3Y300K30D16 Y 150° C 220° C Floor Yes Ventilated 1, 3, 6<br />

500 3F3T500K30D16 Y , T 150° C 220° C Floor Yes Ventilated 1, 3, 6<br />

a Actual taps may vary based on volts/turn ratio.<br />

b Wall designations for units having standard features.<br />

c Ventilated transformers drip shields are UL listed for<br />

outdoor use.<br />

d Encapsulated transformers are UL listed for indoor/<br />

outdoor use. 15kVA with R taps also available in<br />

ventilated enclosure.<br />

e K-Factor transformers equipped with electrostatic shield<br />

and 200% neutral as standard features.<br />

f See table on page 8-8 for available kits.<br />

g Items marked floor and wall can be wall mounted<br />

with optional wall bracket that may be identified with<br />

“W” suffix on catalog number. Wall mounting brackets<br />

will not be available for Series J 75kVA with copper<br />

winding options.<br />

Series H Tap Standard.<br />

Series J Tap Standard.<br />

8-12<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category XFMR


Distribution Dry Type Transformers<br />

Three Phase<br />

Revised on 05/31/18<br />

Selection<br />

Catalog<br />

Temperature<br />

Number Taps a Rise<br />

a Actual taps may vary based on volts/turn ratio.<br />

b Wall designations for units having standard features.<br />

c Ventilated transformers drip shields are UL listed for<br />

outdoor use.<br />

d Encapsulated transformers are UL listed for indoor/<br />

outdoor use. 15kVA with R taps also available in<br />

ventilated enclosure.<br />

Mounting<br />

Type bef<br />

Drip Shield<br />

Provided c<br />

Enclosure<br />

Style – Type d<br />

Optional<br />

Modifications<br />

kVA<br />

Insulation<br />

208 Volts ∆ Primary, 208Y/120 Volts Secondary<br />

3 3B3R003 R 135° C 180° C Wall No Encapsulated – NEMA 3R 1, 2, 3<br />

6 3B3R006 R 135° C 180° C Wall No 1, 2, 3<br />

9 3B3R009 R 135° C 180° C Wall No 1, 2, 3<br />

15 3B3R015 R 135° C 180° C Wall No 1, 2, 3<br />

15 3B3Y015D16 Y 150° C 220° C Floor & Wall Yes Ventilated – NEMA 3R 1, 2, 3, 4, 6<br />

30 3B3Y030D16 Y 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 6<br />

45 3B3Y045D16 Y 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 6<br />

75 3B3Y075D16 Y 150° C 220° C Floor Yes Ventilated – NEMA 3R 1, 2, 3, 6<br />

112.5 3B3Y112D16 Y 150° C 220° C Floor Yes 1, 2, 3, 6<br />

150 3B3M150D16 Y , M 150° C 220° C Floor Yes 1, 2, 3, 6<br />

225 3B3M225D16 S , M 150° C 220° C Floor Yes Ventilated – NEMA 3R 1, 2, 3, 6<br />

300 3B3M300D16 S , M 150° C 220° C Floor Yes 1, 2, 3, 6<br />

500 3B3M500D16 S , M 150° C 220° C Floor Yes 1, 2, 3, 6<br />

208 Volt ∆ Primary, 240 ∆ Secondary with 120 Volt TAP on B Phase g<br />

15 3B1Y015D16 Y 150° C 220° C Floor & Wall Yes Ventilated – NEMA 3R 1, 2, 3, 4, 6<br />

30 3B1Y030D16 Y 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 6<br />

45 3B1Y045D16 Y 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 6<br />

75 3B1Y075D16 Y 150° C 220° C Floor Yes Ventilated – NEMA 3R 1, 2, 3, 6<br />

112.5 3B1Y112D16 Y 150° C 220° C Floor Yes 1, 2, 3, 6<br />

150 3B1M150D16 Y , M 150° C 220° C Floor Yes 1, 2, 3, 6<br />

225 3B1M225D16 Y , M 150° C 220° C Floor Yes 1, 2, 3, 6<br />

208 Volts ∆ Primary, 480Y/277 Volts Secondary<br />

9 3B5R009 R 135° C 180° C Wall No Encapsulated – NEMA 3R 1, 2, 3<br />

15 3B5R015 R 135° C 180° C Wall No 1, 2, 3<br />

15 3B5Y015D16 Y 150° C 220° C Floor & Wall Yes Ventilated – NEMA 3R 1, 2, 3, 4, 6<br />

30 3B5Y030D16 Y 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 6<br />

45 3B5Y045D16 Y 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 6<br />

75 3B5Y075D16 Y 150° C 220° C Floor Yes Ventilated – NEMA 3R 1, 2, 3, 6<br />

112.5 3B5Y112D16 Y 150° C 220° C Floor Yes 1, 2, 3, 6<br />

150 3B5M150D16 Y , M 150° C 220° C Floor Yes 1, 2, 3, 6<br />

225 3B5M225D16 S , M 150° C 220° C Floor Yes Ventilated – NEMA 3R 1, 2, 3, 6<br />

300 3B5M300D16 S , M 150° C 220° C Floor Yes 1, 2, 3, 6<br />

500 3B5M500D16 S , M 150° C 220° C Floor Yes 1, 2, 3, 6<br />

240 Volts ∆ Primary, 208Y/120 Volts Secondary<br />

15 3C3Y015D16 Y 150° C 220° C Floor & Wall Yes Ventilated – NEMA 3R 1, 2, 3, 4, 6<br />

30 3C3Y030D16 Y 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 6<br />

45 3C3Y045D16 Y 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 6<br />

75 3C3Y075D16 Y 150° C 220° C Floor Yes Ventilated – NEMA 3R 1, 2, 3, 6<br />

112.5 3C3Y112D16 Y 150° C 220° C Floor Yes 1, 2, 3, 6<br />

150 3C3Y150D16 Y 150° C 220° C Floor Yes 1, 2, 3, 6<br />

225 3C3M225D16 S , M 150° C 220° C Floor Yes Ventilated – NEMA 3R 1, 2, 3, 6<br />

300 3C3M300D16 S , M 150° C 220° C Floor Yes 1, 2, 3, 6<br />

500 3C3M500D16 S , M 150° C 220° C Floor Yes 1, 2, 3, 6<br />

240 Volts ∆ Primary, 480Y/277 Volts Secondary<br />

15 3C5Y015D16 Y 150° C 220° C Floor & Wall Yes Ventilated – NEMA 3R 1, 2, 3, 4, 6<br />

30 3C5Y030D16 Y 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 6<br />

45 3C5Y045D16 Y 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 6<br />

75 3C5Y075D16 Y 150° C 220° C Floor Yes Ventilated – NEMA 3R 1, 2, 3, 6<br />

112.5 3C5Y112D16 Y 150° C 220° C Floor Yes 1, 2, 3, 6<br />

150 3C5Y150D16 Y 150° C 220° C Floor Yes 1, 2, 3, 6<br />

225 3C5M225D16 S , M 150° C 220° C Floor Yes Ventilated – NEMA 3R 1, 2, 3, 6<br />

300 3C5M300D16 S , M 150° C 220° C Floor Yes 1, 2, 3, 6<br />

500 3C5M500D16 S , M 150° C 220° C Floor Yes 1, 2, 3, 6<br />

Optional Modifications Table<br />

Optional (commonly used)<br />

Modifications<br />

1a. 115° C Rise F<br />

1b. 80° C Rise B<br />

2. Electrostatic Shield ES<br />

3. Copper Windings C<br />

4. Wall Mounting Brackets1 W<br />

6. Low noise—XdB below std. LNX<br />

Catalog<br />

Suffix Code<br />

Taps<br />

Description<br />

Designation<br />

None<br />

N<br />

2–5% FCBN R<br />

2–5% (1 FCAN, 1 FCBN) S<br />

2–2.5% FCBN U<br />

6–2.5% (2 FCAN, 4 FCBN) Y<br />

e See table on page 8-8 for available kits.<br />

f Items marked floor and wall can be wall mounted<br />

with optional wall bracket that may be identified<br />

with “W” suffix on catalog number. Wall mounting<br />

brackets will not be available for Series J 75kVA with<br />

copper winding options.<br />

Seismic Ratings<br />

Series J Rating Information (see page 8-8)<br />

Phase 1<br />

Phase 3<br />

1kVA-500kVA (Floor Mounted)<br />

S DS =2.00g ; z/h = 1.00 ; I p = 1.5<br />

g Reduced capacity 1-phase tap— When utilizing 1-phase<br />

tap at 5%, the 3-phase load is reduced to 85% max. (5%<br />

reduction on 3 coils). 10% of rated kVA absolute<br />

maximum (evenly balanced on each side of lighting tap).<br />

When utilizing 1-phase tap at 10%, the 3-phase<br />

load is reduced to 70% max. (10% reduction on 3 coils).<br />

Results are filed with OSHPD per OSP-0109-10.<br />

Series H Tap Standard.<br />

Series J Tap Standard.<br />

8 TRANSFORMERS<br />

Product Category XFMR<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 8-13


Distribution Dry Type Transformers<br />

Three Phase<br />

Revised on 05/15/18<br />

Selection<br />

kVA<br />

Catalog<br />

Temperature<br />

Number Taps a Rise<br />

Insulation<br />

Mounting<br />

Type bi<br />

Drip Shield<br />

Provided c<br />

Enclosure<br />

Style d<br />

Optional<br />

Modifications<br />

600 Volts ∆ Primary, 208Y/120 Volts Secondary<br />

3 3G3R003 R 135° C 180° C Wall No Encapsulated – NEMA 3R 1, 2, 3<br />

6 3G3R006 R 135° C 180° C Wall No 1, 2, 3<br />

9 3G3R009 R 135° C 180° C Wall No 1, 2, 3<br />

15 3G3R015 R 135° C 180° C Wall No 1, 2, 3<br />

15 3G3T015D16 Y , T 150° C 220° C Floor & Wall Yes Ventilated – NEMA 3R 1, 2, 3, 4, 6<br />

30 3G3T030D16 Y , T 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 6<br />

45 3G3T045D16 Y , T 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 6<br />

75 3G3T075D16 Y , T 150° C 220° C Floor Yes Ventilated – NEMA 3R 1, 2, 3, 6<br />

112.5 3G3T112D16 Y , T 150° C 220° C Floor Yes 1, 2, 3, 6<br />

150 3G3T150D16 Y , T 150° C 220° C Floor Yes 1, 2, 3, 6<br />

225 3G3T225D16 Y , T 150° C 220° C Floor Yes 1, 2, 3, 6<br />

300 3G3T300D16 Y , T 150° C 220° C Floor Yes 1, 2, 3, 6<br />

500 3G3T500D16 Y , T 150° C 220° C Floor Yes 1, 2, 3, 6<br />

600 Volts ∆ Primary, 480Y/277 Volts Secondary<br />

3 3G5R003 R 135° C 180° C Wall No Encapsulated – NEMA 3R 1, 2, 3<br />

6 3G5R006 R 135° C 180° C Wall No 1, 2, 3<br />

9 3G5R009 R 135° C 180° C Wall No 1, 2, 3<br />

15 3G5R015 R 135° C 180° C Wall No 1, 2, 3<br />

15 3G5T015D16 Y , T 150° C 220° C Floor & Wall Yes Ventilated – NEMA 3R 1, 2, 3, 4, 6<br />

30 3G5T030D16 Y , T 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 6<br />

45 3G5T045D16 Y , T 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 6<br />

75 3G5T075D16 Y , T 150° C 220° C Floor Yes Ventilated – NEMA 3R 1, 2, 3, 6<br />

112.5 3G5T112D16 Y , T 150° C 220° C Floor Yes 1, 2, 3, 6<br />

150 3G5T150D16 Y , T 150° C 220° C Floor Yes 1, 2, 3, 6<br />

225 3G5T225D16 Y , T 150° C 220° C Floor Yes 1, 2, 3, 6<br />

300 3G5T300D16 Y , T 150° C 220° C Floor Yes 1, 2, 3, 6<br />

500 3G5T500D16 Y , T 150° C 220° C Floor Yes 1, 2, 3, 6<br />

Dual Purpose Auto Transformers <br />

8<br />

600V Pri<br />

480V Sec<br />

kVA<br />

480V Pri<br />

380V Sec<br />

Catalog<br />

Temperature<br />

Number Taps a Rise<br />

Insulation<br />

Mounting<br />

Type b<br />

Drip Shield<br />

Required c<br />

Enclosure<br />

Style d<br />

Optional<br />

Modifications<br />

600 Volts Primary, 480 Volts Secondary 3Ø 60 Hz OR— 480 Volts Primary 380 Volts Secondary 3Ø 50/60 Hz Alternate Rating<br />

15 12 3G4N015A N 80° C 130° C Wall No Encapsulated – NEMA 3R —<br />

30 24 3G4N030A N 115° C 180° C Wall No —<br />

45 36 3G4N045A N 150° C 220° C Floor & Wall Yes Ventilated – NEMA 3R 4, 5<br />

75 60 3G4N075A N 150° C 220° C Floor & Wall Yes 4, 5<br />

112.5 90 3G4N112A N 150° C 220° C Floor & Wall Yes 4, 5<br />

150 120 3G4N150A N 150° C 220° C Floor & Wall Yes 4, 5<br />

225 180 3G4N225A N 150° C 220° C Floor & Wall Yes 4, 5<br />

300 240 3G4N300A N 150° C 220° C Floor Yes 5<br />

500 400 3G4N500A N 150° C 220° C Floor Yes 51<br />

TRANSFORMERS<br />

Optional Modifications Table (Contact Sales office for List Price)<br />

Optional (commonly used) Catalog<br />

Modifications<br />

Suffix Code<br />

1a. 115° C Rise F<br />

1b. 80° C Rise B<br />

2. Electrostatic Shield ES<br />

3. Copper Windings C<br />

4. Wall Mounting Brackets1 W<br />

6. Low noise - XdB below std. LNX<br />

Taps<br />

Description<br />

Designation<br />

None<br />

N<br />

2–5% FCBN R<br />

2–5% (1 FCAN, 1 FCBN) S<br />

2–2.5% FCBN U<br />

6–2.5% (2 FCAN, 4 FCBN) Y<br />

a Actual taps may vary based on volts/turn ratio.<br />

b Wall designations for units having standard features.<br />

c Ventilated transformers drip shields are UL listed for<br />

outdoor use.<br />

d Encapsulated transformers are UL listed for indoor/<br />

outdoor use.<br />

If used on unbalanced loads, these auto transformers will<br />

need to be used on a 4-wire system with the supply<br />

neutral connected to the transformer. If used on motor<br />

loads, then they may be used on a 3-wire system without<br />

a neutral or fourth wire. Review in NEC 450-4 and 450-5.<br />

Items marked floor and wall can be wall mounted<br />

with optional wall bracket that may be identified<br />

with “W” suffix on catalog number. Wall mounting<br />

brackets will not be available for Series J 75kVA with<br />

copper winding options. See pages 8-8 and 8-27 for<br />

details.<br />

Series H Tap Standard.<br />

Series J Tap Standard.<br />

i See table on page 8-8 for available kits.<br />

8-14<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category XFMR


Distribution Dry Type Transformers<br />

Motor Drive Isolation<br />

Selection<br />

Motor Drive Isolation<br />

For industrial and commercial<br />

applications with SCR-controlled<br />

adjustable speed motor drives, and AC<br />

adjustable frequency or DC drives.<br />

Designed for use with motor drives,<br />

the drive isolation transformer must<br />

isolate the motor from the line and<br />

handle the added loads of the drivecreated<br />

harmonics.<br />

Drive isolation transformers are<br />

engineered for both AC adjustable<br />

frequency and DC motor drives.<br />

They are specifically designed to<br />

accommodate the electrical and<br />

mechanical stresses, regenerative<br />

current reversals and frequent short<br />

circuits, inherent in severe drive duty<br />

cycles.<br />

Three Phase 60HZ Motor Drive Isolation Transformers<br />

Motor Catalog Standard Mounting Drip Shield Optional<br />

kVA H.P. d Number Taps Rise Insulation Type Required b Modifications<br />

7.5 3 & 5 DT ( ) 007 S 135° C 180° C Floor & Wall No 1, 2, 3<br />

11 7.5 DT ( ) 011 S 135° C 180° C Floor & Wall No 1, 2, 3<br />

14 10 DT ( ) 014 S 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 5, 6<br />

20 15 DT ( ) 020 S 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 5, 6<br />

27 20 DT ( ) 027 S 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 5, 6<br />

34 25 DT ( ) 034 S 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 5, 6<br />

40 30 DT ( ) 040 S 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 5, 6<br />

51 40 DT ( ) 051 S 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 5, 6<br />

63 50 DT ( ) 063 S 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 5, 6<br />

75 60 DT ( ) 075 S 150° C 220° C Floor Yes 1, 2, 3, 5, 6<br />

93 75 DT ( ) 093 S 150° C 220° C Floor Yes 1, 2, 3, 5, 6<br />

118 100 DT ( ) 118 S 150° C 220° C Floor Yes 1, 2, 3, 5, 6<br />

145 125 DT ( ) 145 S 150° C 220° C Floor Yes 1, 2, 3, 5, 6<br />

175 150 DT ( ) 175 S 150° C 220° C Floor Yes 1, 2, 3, 5, 6<br />

220 200 DT ( ) 220 S 150° C 220° C Floor Yes 1, 2, 3, 5, 6<br />

275 250 DT ( ) 275 S 150° C 220° C Floor Yes 1, 2, 3, 5, 6<br />

330 300 DT ( ) 330 S 150° C 220° C Floor Yes 1, 2, 3, 5, 6<br />

440 400 DT ( ) 440 S 150° C 220° C Floor Yes 1, 2, 3, 5, 6<br />

550 500 DT ( ) 550 S 150° C 220° C Floor Yes 1, 2, 3, 5, 6<br />

660 600 DT ( ) 660 S 150° C 220° C Floor Yes 1, 2, 3, 5, 6<br />

DT ( ) Code Primary Volts Secondary Volts<br />

18 208 Delta 208Y/120<br />

20 208 Delta 230Y/133<br />

21 208 Delta 460Y/266<br />

22 230 Delta 230Y/133<br />

24 230 Delta 460Y/266<br />

30 380 Delta 460Y/266<br />

42 460 Delta 230Y/133<br />

44 460 Delta 460Y/266<br />

45 460 Delta 380Y/220<br />

52 575 Delta 230Y/133<br />

54 575 Delta 460Y/266<br />

Motor Drive Isolation<br />

Catalog<br />

Optional Modifications<br />

Suffix Code<br />

1a. 115° C Rise F<br />

1b. 080° C Rise B<br />

2. Electrostatic Shield ES<br />

3. Copper Windings C<br />

4. Wall Mounting Brackets W<br />

5. Drip Shields/Weather Shields DS<br />

6. Thermal Switches TS<br />

(Contact Sales office for List Price)<br />

8 TRANSFORMERS<br />

a Actual taps may vary based on volts/turn ratio.<br />

b For outdoor application. Ventilated transformers<br />

requiring drip shields are UL listed for outdoor use. No<br />

charge when requested at time of initial project order.<br />

c Items marked floor and wall can be wall mounted with<br />

optional wall bracket identified with “W” suffix on<br />

catalog number. See pages 8-8 and 8-27 for<br />

details.<br />

d Refer selection and application guide for additional<br />

information on horsepower, Ampere, kVA ratings and<br />

applications. Standard taps varies with design volts/<br />

turn ratio.<br />

Product Category XFMR<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 8-15


Distribution Dry Type Transformers<br />

Sentron Power Centers – Plug-In Series<br />

Revised on 02/28/19<br />

Selection<br />

Economical Space Saving Package<br />

Siemens Sentron Power Center is a<br />

pre-wired combination of a primary<br />

breaker disconnect, dry type shielded<br />

transformer, secondary breaker<br />

disconnect and a secondary power panel<br />

all in one convenient package.<br />

You save time, space and money by not<br />

having to individually assemble, mount<br />

and wire these components. Simply add<br />

the branch and you’re ready to go.<br />

UL-3R Enclosures<br />

All Sentron Power Center enclosures are<br />

UL-3R listed for indoor and outdoor use.<br />

Transformer Assembly<br />

Siemens totally encapsulated distribution<br />

transformers are designed for general<br />

purpose indoor/outdoor operation.<br />

Sentron Power Centers can be installed<br />

in a wide variety of atmospheric and<br />

environmental conditions. A 180°C, UL<br />

recognized insulation system is used<br />

with a 115°C temperature rise.<br />

Sentron Power Center units are electrostatically<br />

shielded to provide transient<br />

voltage protection at no extra cost. All<br />

units have 2-5% FCBN taps.<br />

Panel Assembly<br />

The power panel assembly will<br />

accommodate one-inch, 1, 2 or 3-pole,<br />

common trip, duplex secondary branch<br />

circuit breakers, Type Q and QT as well<br />

as ground fault circuit breakers. Per UL<br />

and NEC requirements, the Sentron<br />

Power Center assembly comes fully<br />

equipped with primary and secondary<br />

main circuit breakers. Branch circuit<br />

breakers can be obtained from our local<br />

distributor once you have established<br />

your branch circuit requirements. All<br />

Sentron Power Centers are UL listed<br />

for service entrance.<br />

* Not Seismic rated<br />

** Not available for Buy America<br />

a<br />

Number Reference kVA<br />

120V (1-Pole) 120V (1-Pole) 240V (2-pole) Height Width Depth Net Weight (lbs.)<br />

Maximum Secondary Circuits<br />

Interior<br />

Catalog 1" Wide 1/2" Wide 2" Wide Number<br />

Approximate Dimensions (in inches) Approximate<br />

480 Volts Primary, 240/120 Volts Secondary — Single Phase b — Sentron Power Centers e<br />

5.0 1LPC005 8 16 4 I1224ML1100 32.13 13.25 7.63 120<br />

7.5 1LPC007 8 16 4 I1224ML1100 32.13 15.88 11.00 160<br />

10.0 1LPC010 8 16 4 I1224ML1100 34.38 15.88 11.00 185<br />

15.0 1LPC015 12 24 6 I1224L1125CU 34.38 17.13 12.38 240<br />

25.0 1LPC025 20 40 10 I2440L1200CU 41.88 17.88 13.50 330<br />

8<br />

TRANSFORMERS<br />

a Number h Reference h kVA<br />

120V (1-Pole) 120V (1-Pole) 208V (3-pole) Height Width Depth Net Weight (lbs.)<br />

Maximum Secondary Circuits<br />

Interior<br />

Catalog 1" Wide 1/2" Wide 3" Wide Number<br />

Approximate Dimensions (in inches) Approximate<br />

480 Volts ∆ Primary, 208Y/120 Volts Secondary — Three Phase — Sentron Power Centers <br />

9.0 3LPC009 12 24 4 Pl1836L3200CUB 33.75 22.13 7.63 255<br />

15.0 3LPC015 12 24 4 Pl1836L3200CUB 35.13 22.13 12.38 385<br />

22.5 3LPC022 18 36 6 Pl2442L3200CUB 38.25 30.25 13.38 535<br />

30.0 3LPC030 24 42 8 Pl3054L3200CUB 43.75 33.00 13.75 680<br />

Circuit Breaker Data for Plug-In Sentron Power Centers<br />

480 Volts to 240/120 Volts — Single Phase<br />

480 Volts ∆ to 208Y/120 Volts — Three Phase<br />

480 Volts 240/120 Volts Maximum Rating<br />

Primary Secondary of Secondary<br />

kVA Breaker af Main Breakers<br />

5.0 ED42B025L (25A) Q225 (25A) 20 Amps<br />

7.5 ED42B025L (25A) Q240 (40A) 30 Amps<br />

10.0 ED42B035L (35A) Q250 (50A) 40 Amps<br />

15.0 ED42B050L (50A) Q270 (70A) 60 Amps<br />

25.0 ED42B090L (90A) Q2125 (125A) 100 Amps<br />

480 Volts 208Y/120 Volts Maximum Rating<br />

Primary Secondary of Secondary<br />

kVA Breaker af Main Breakers<br />

9.0 ED43B025L (25A) Q330 (30A) 25 Amps<br />

15.0 ED43B040L (40A) Q350 (50A) 40 Amps<br />

22.5 ED43B070L (70A) Q370 (70A) 60 Amps<br />

30.0 ED43B090L (90A) Q3100 (100A) 80 Amps<br />

a Primary breaker has lineside lug for customer<br />

connection.<br />

b 18,000 Amps RMS Symmetrical Interrupting Capacity.<br />

Sentron Power Centers are NEMA 3R for outdoor<br />

application and may be ordered with “SS” suffix for<br />

304 stainless steel enclosure. For 316 stainless steel add<br />

suffix SS316.<br />

Secondary branch breakers are not included and must<br />

be ordered separately.<br />

Primary and secondary main breakers are included and<br />

are factory installed.<br />

ED frame breakers furnished are rated 18000 AIC and<br />

are sufficient for fault current of transformer. No other<br />

breakers are currently approved for use.<br />

Copper windings are standard on 1LPC005 and 3LPC009.<br />

Add CU to other partnumber to get copper windings.<br />

h CU and CUB interiors have tin plated copper bus.<br />

1-Phase 5 thru 10kVA have aluminum bus. CUB refers to<br />

OEM interior verses CU un-assembled interior.<br />

8-16<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Distribution Dry Type Transformers<br />

Sentron Power Centers – Bolt-on Series<br />

Revised on 05/15/18<br />

Selection<br />

Bolt-on Breaker Option<br />

The same economical space saving package, NEMA 3R rated enclosure, and UL<br />

listed transformer of the original Sentron Power Center but now available with<br />

more robust BOLT-ON BREAKERS.<br />

Panel Assembly<br />

This version of the Sentron Power Center uses our UL Recognized P1 Lighting<br />

Panel interior with the following ratings & features:<br />

J 200 kA Short Circuit rating<br />

J 240 Volts maximum (when using type BL branch devices)<br />

J 250 Amps maximum<br />

J Copper bus<br />

J 18 circuit panel for 15kVA and below<br />

J 30 circuit panel for designs above 15kVA<br />

The power panel assembly will accommodate one-inch, 1, 2, or 3-pole type BL,<br />

BLH, HBL branch Breakers, to include the BL family of AFCI, GFCI, Ground Fault,<br />

Switching Neutrals, HID Lighting, Tungsten Lighting, and Molded Case Switches.<br />

The Sentron Power Center assembly comes fully equipped with transformer primary<br />

and secondary main circuit breakers. Branch circuit breakers can be obtained from<br />

our local distributor once you have established your branch circuit requirements.<br />

All Sentron Power Centers are UL listed for service entrance applications.<br />

* Not Seismic rated<br />

** Buy America may be available on some models. Catalog numbers will end in<br />

“BA.” Lead times will be affected. Please contact Customer Support for more<br />

information.<br />

Voltage rating: 480 - 240/120, Single Phase b , Sentron Power Center e<br />

kVA<br />

Catalog<br />

Maximum Secondary Circuits Approximate Dimensions (inches)<br />

Number 1” Wide 2” Wide Interior Part Number Height Width Depth<br />

Approximate<br />

Weight (lbs.)<br />

5 1LPC005JA 16 8 K11D255001 38.00 15.88 11.00 165<br />

7.5 1LPC007JA 16 8 K11D255001 38.00 15.88 11.00 165<br />

10 1LPC010JA 16 8 K11D255001 38.00 17.13 12.38 240<br />

15 1LPC015JA 16 8 K11D255001 38.00 17.13 12.38 240<br />

25 1LPC025JA 28 14 K11D255002 45.19 17.88 13.50 330<br />

Voltage rating: 480 Delta - 208Y/120, Three Phase, Sentron Power Center d<br />

kVA<br />

Catalog<br />

Maximum Secondary Circuits a Approximate Dimensions (inches)<br />

Number 1” Wide 2” Wide Interior Part Number Height Width Depth<br />

Circuit Breaker Data for Bolt-on Sentron Power Centers<br />

For Single Phase Sentron Power Centers<br />

For Three Phase Sentron Power Centers<br />

Approximate<br />

Weight (pounds)<br />

9 3LPC009JA 15 7 K11D255201 33.75 22.13 7.63 255<br />

15 3LPC015JA 15 7 K11D255201 35.13 22.13 12.38 385<br />

22.5 3LPC022JA 27 13 K11D255202 43.75 33.00 13.75 680<br />

30 3LPC030JA 27 13 K11D255202 43.75 33.00 13.75 680<br />

kVA<br />

Transformer<br />

Primary Breaker <br />

Panel Secondary<br />

Main Breaker<br />

Maximum rating of<br />

Branch Breakers (Amps)<br />

5 ED42B025L (25A) B230H (30A) 20<br />

7.5 ED42B025L (25A) B240H (40A) 30<br />

10 ED42B035L (35A) B250H (50A) 40<br />

15 ED42B050L (50A) B270 (70A) 60<br />

25 ED42B090L (90A) B2125 (125A) 100<br />

kVA<br />

Transformer<br />

Primary Breaker <br />

Panel Secondary<br />

Main Breaker<br />

Maximum rating of<br />

Branch Breakers (Amps)<br />

9 ED43B025L (25A) B330H (30A) 25<br />

15 ED43B040L (40A) B350H (50A) 40<br />

22.5 ED43B070L (70A) B370 (70A) 60<br />

30 ED43B090L (90A) B3100 (100A) 80<br />

8 TRANSFORMERS<br />

a Primary breaker has lineside lug for customer<br />

connection.<br />

b 18,000 Amps RMS Symmetrical Interrupting Capacity.<br />

Sentron Power Centers are NEMA 3R for outdoor<br />

application and may be ordered with “SS” suffix for<br />

304 stainless steel enclosure. For 316 stainless steel add<br />

suffix SS316.<br />

Secondary branch breakers are not included and must<br />

be ordered separately.<br />

Primary and secondary main breakers are included and<br />

are factory installed.<br />

ED frame breakers furnished are rated 18000 AIC and are<br />

sufficient for fault current of transformer. No other breakers<br />

are currently approved for use.<br />

Standard windings are aluminum. Add “CU” at end<br />

for copper windings. Contact customer support for<br />

assistance.<br />

Excluding Secondary Main Breaker that<br />

takes up 2 poles.<br />

Excluding Secondary Main Breaker that<br />

takes up 3 poles.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 8-17


Transformers<br />

High Efficiency Transformer<br />

Selection<br />

DOE 2016 Efficiency Standards<br />

The Department of Energy (DOE) 10<br />

CFR 431 has released new efficiency<br />

standards which will be put into effect<br />

January 1, 2016. These standards<br />

surpass and supersede NEMA TP1<br />

efficiency standards. All low-voltage drytype<br />

three-phase ventilated transformers<br />

from 15 kVA through 1000kVA must be<br />

manufactured to these standards after<br />

January 1, 2016. DOE 2016 standards<br />

also apply to Harmonic Mitigating<br />

Transformers (See pages 8-19 – 8-20).<br />

Transformers manufactured to DOE<br />

2016 efficiencies must meet efficiency<br />

levels with a 35% load and temperature<br />

of 75°C. Transformers with DOE 2016<br />

standards have grain-oriented, nonaging<br />

silicon steel cores. DOE 2016<br />

standards do not apply to single phase,<br />

encapsulated, motor drive isolation, and<br />

auto transformers.<br />

High Efficiency Transformers<br />

Single Phase<br />

Three Phase<br />

kVA TP1 Efficiency kVA DOE 2016 Efficiency<br />

15 97.70% 15 97.89%<br />

25 98.00% 30 98.23%<br />

37.5 98.20% 45 98.40%<br />

50 98.30% 75 98.60%<br />

75 98.50% 112.5 98.74%<br />

100 98.60% 150 98.83%<br />

167 98.70% 225 98.94%<br />

250 98.80% 300 99.02%<br />

333 98.90% 500 99.14%<br />

750 99.23%<br />

1000 99.28%<br />

8<br />

NEMA TP1 Efficiency Standards<br />

NEMA TP1 will still be a valid efficiency<br />

standard for single phase transformers<br />

after January 1, 2016. The TP1 designs<br />

use high grade electrical steel and other<br />

features to lower flux density and reduce<br />

losses especially at average 35% loading<br />

where the TP1 measurements apply.<br />

The core construction employs the use<br />

of high quality grain-oriented, non-aging<br />

silicon steel with high permeability, low<br />

hysteresis, and low eddy current losses.<br />

These characteristics are required to<br />

achieve the TP1 efficiency levels. Core<br />

laminations must be tightly assembled<br />

enabling magnetic flux densities to be<br />

kept well below the saturation point.<br />

TRANSFORMERS<br />

8-18<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Transformers<br />

Sentron Harmonic Mitigating Transformers (HD1)<br />

Selection<br />

Description<br />

The Sentron Harmonic Mitigating<br />

Transformers (HMTs) are designed to<br />

meet the needs of modern power<br />

distribution systems that contain a large<br />

percentage of non-linear equipment that<br />

produces harmonics. Some examples of<br />

this type of equipment are computers,<br />

printers, fax machines, scanners, copiers,<br />

uninterruptible power supplies, ballast<br />

and variable frequency drives (VFD).<br />

This type of equipment generates<br />

harmonic voltages and currents because<br />

they contain AC to DC power conversion<br />

rectifiers. Harmonic voltages and<br />

currents can cause a variety of problems<br />

ranging from poor power factor, voltage<br />

distortion, capacitor resonance and<br />

motor failures to overloaded transformers<br />

and conductors.<br />

The Sentron HMTs are specially designed<br />

to operate under high non-linear load<br />

conditions and have the additional benefit<br />

of improving the overall power system<br />

reliability.<br />

Application<br />

One of the most effective ways to<br />

eliminate power system harmonics is to<br />

use a technique known as “phase<br />

shifting.” In this method power system<br />

harmonics are eliminated by pairing<br />

together harmonics that have 180°<br />

relative angular displacement, which<br />

causes them to cancel one another out.<br />

This can be accomplished by a variety<br />

of means:<br />

Single Output Harmonic<br />

Mitigating Transformer<br />

(0° or -30° primary-secondary<br />

angular displacement)<br />

n The primary of this transformer has a<br />

delta connection and its secondary has<br />

a special double winding connection.<br />

Although there is only one secondary<br />

three phase output, the 3 rd , 9 th and 15 th<br />

harmonic currents are prevented from<br />

circulating in the primary windings by<br />

canceling their magnetic fluxes at low<br />

impedance with the double winding<br />

secondary, reducing voltage distortions<br />

to the loads.<br />

n When two transformers with this<br />

type of connection, 0° and -30°<br />

displacement, are used in parallel,<br />

the 3 rd , 9 th and 15 th harmonic currents<br />

are canceled as previously described,<br />

and additionally the 5 th and 7 th harmonic<br />

currents are cancelled in the electrical<br />

supply common to both transformers<br />

due to their relative 30° phase shift.<br />

n If a single harmonic mitigating<br />

transformer (0°) is used in an existing<br />

or new system utilizing standard<br />

delta-wye transformers (-30°), the 5 th<br />

and 7 th harmonic currents originating<br />

from the HMT transformer (0°) will<br />

attempt to cancel the 5 th and 7 th<br />

harmonic currents originating from the<br />

standard delta-wye transformer (-30°).<br />

This reduces the overall 5 th and 7 th<br />

harmonics present in the system, with<br />

the actual reduction dependent on the<br />

magnitudes of the secondary loads.<br />

Benefits<br />

Elimination of undesirable harmonics by<br />

using the Siemens Sentron HMTs is an<br />

effective solution to the power quality<br />

problems encountered by today’s power<br />

system professionals. By treating the<br />

harmonics at their source, using<br />

advanced technology, installation<br />

problems can be avoided and overall<br />

system reliability improved. The Sentron<br />

HMT product line provides many far<br />

reaching benefits such as lower<br />

operating cost, improved operating<br />

efficiency, reduced down-time due to<br />

outages caused by nuisance tripping,<br />

and increased equipment life due to<br />

low-voltage distortions.<br />

Design and Construction<br />

Features<br />

The Sentron Harmonic Mitigating<br />

Transformers comply with all applicable<br />

ANSI/IEEE standards including<br />

C57.12.91, C57.96, C57.110, CSA #<br />

C22.2 No. 47 (CUL), UL506, UL1561 as<br />

well as NEMA ST-20. The design life is<br />

25 years at 150 degree C rise, 30 years<br />

at 115C rise and 40 years for 80C rise<br />

models. Approvals and listings include<br />

UL, CSA. with CE approval available<br />

when requested. The Sentron HMTs<br />

have capability of K-factor up to K-13,<br />

which is achieved by harmonic<br />

cancellations in the secondary and low<br />

flux density design for protection against<br />

heat in place of design enlargement<br />

protection only. Both copper and<br />

aluminum coil windings are available<br />

and full width copper foil electrostatic<br />

shield is standard. Additional shield<br />

options are available for higher noise<br />

attenuation requirements. All HMTs<br />

have 150C rise with optional 130C, 115C<br />

and 80C winding rise designs available.<br />

All designs include vacuum impregnated<br />

polyester resin encapsulation of<br />

windings and NEMA 3R enclosures.<br />

A neutral sized at 200% of the ampacity<br />

of the secondary phase conductors for<br />

extra protection against triplens and<br />

unbalanced single phase loads. The<br />

Sentron HMT designs have DOE 2016<br />

energy efficient rating equal to that of a<br />

non K-Factor rated transformer.<br />

Siemens HMT designs have DOE 2016<br />

efficiency levels at 35% load @ ref<br />

temp. 75 degree C.<br />

8 TRANSFORMERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 8-19


Transformers<br />

Sentron Harmonic Mitigating Transformers (HD1)<br />

Catalog Number Coding:<br />

Single output (1 secondary) = HD1,<br />

Phase Shift Options: HD1 followed by > (00) or (30) degree.<br />

HMT, 480 Volt Primary 208Y/120 Volt Secondary (3F3)–150C<br />

(standard), 115C and 80C Winding Rise displayed on this page.<br />

HMTs are also available with 480–480Y/277 (3F5), 208–<br />

208Y/120 (3B3), 208–480Y/277 (3B5).<br />

Selection<br />

Standard Features Include:<br />

n K-13 Load profile rating.<br />

n DOE 2016 Efficiencies at 35% load.<br />

n (C) Copper windings or Aluminum windings (no suffix code).<br />

n (ES) Electrostatic shield.<br />

n 150 C Winding rise.<br />

Changes after January 1, 2016: 2 output, 15 & 45 deg Lag &<br />

130 deg C temp rise will no longer be standard. They can be<br />

provided with a special quote from MAP.<br />

kVA<br />

150C (Std)<br />

Rise HMT<br />

Catalog Number a<br />

115C<br />

Rise HMT<br />

Catalog Number a<br />

80C<br />

Rise HMT<br />

Catalog Number a<br />

Secondary Configuration<br />

Enclosure<br />

Style<br />

Optional HMT<br />

Modifications<br />

Outputs Phase Shift<br />

15 3F3Y015CHD100 3F3Y015FCHD100 3F3Y015BCHD100 1 Zero Degree Vented A,B,C,D,E,F,G<br />

15 3F3Y015CHD130 3F3Y015FCHD130 3F3Y015BCHD130 1 30 Deg Lagging Vented A,B,C,D,E,F,G<br />

30 3F3Y030CHD100 3F3Y030FCHD100 3F3Y030BCHD100 1 Zero Degree Vented A,B,C,D,E,F,G<br />

30 3F3Y030CHD130 3F3Y030FCHD130 3F3Y030BCHD130 1 30 Deg Lagging Vented A,B,C,D,E,F,G<br />

45 3F3Y045CHD100 3F3Y045FCHD100 3F3Y045BCHD100 1 Zero Degree Vented A,B,C,D,E,F,G<br />

45 3F3Y045CHD130 3F3Y045FCHD130 3F3Y045BCHD130 1 30 Deg Lagging Vented A,B,C,D,E,F,G<br />

75 3F3Y075CHD100 3F3Y075FCHD100 3F3Y075BCHD100 1 Zero Degree Vented A,B,C,D,E,F,G<br />

75 3F3Y075CHD130 3F3Y075FCHD130 3F3Y075BCHD130 1 30 Deg Lagging Vented A,B,C,D,E,F,G<br />

112.5 3F3Y112CHD100 3F3Y112FCHD100 3F3Y112BCHD100 1 Zero Degree Vented A,B,C,D,E,F,G<br />

112.5 3F3Y112CHD130 3F3Y112FCHD130 3F3Y112BCHD130 1 30 Deg Lagging Vented A,B,C,D,E,F,G<br />

150 3F3Y150CHD100 3F3Y150FCHD100 3F3Y150BCHD100 1 Zero Degree Vented A,B,C,D,E,F,G<br />

150 3F3Y150CHD130 3F3Y150FCHD130 3F3Y150BCHD130 1 30 Deg Lagging Vented A,B,C,D,E,F,G<br />

225 3F3Y225CHD100 3F3Y225FCHD100 3F3Y225BCHD100 1 Zero Degree Vented A,B,C,D,E,F,G<br />

225 3F3Y225CHD130 3F3Y225FCHD130 3F3Y225BCHD130 1 30 Deg Lagging Vented A,B,C,D,E,F,G<br />

300 3F3Y300CHD100 3F3Y300FCHD100 3F3Y300BCHD100 1 Zero Degree Vented A,B,C,D,E,F,G<br />

300 3F3Y300CHD130 3F3Y300FCHD130 3F3Y300BCHD130 1 30 Deg Lagging Vented A,B,C,D,E,F,G<br />

500 3F3Y500CHD100 3F3Y500FCHD100 3F3Y500BCHD100 1 Zero Degree Vented C,D,E,F,G<br />

500 3F3Y500CHD130 3F3Y500FCHD130 3F3Y500BCHD130 1 30 Deg Lagging Vented C,D,E,F,G<br />

Optional Modifications Table for HMTs<br />

8<br />

TRANSFORMERS<br />

A<br />

B<br />

C<br />

E<br />

F<br />

Sound Level<br />

LN3= (3dB below NEMA standard)<br />

LN5= (5dB below NEMA standard)<br />

Attenuation—Single shield—60dB Common Mode Std.<br />

ES2= Double shield—80dB Common Mode > <br />

Filtering & Attenuation<br />

TV= Secondary side TVSS (100kA & 200kA available)<br />

with common mode noise attenuation<br />

TB= Terminal Block<br />

G<br />

G<br />

G<br />

G<br />

G<br />

G<br />

G<br />

G<br />

G<br />

Thermal Sensors 170° C= (TS7), 185° C= (TS8) or 200° C= (TS0)<br />

TS7 = 1 sensor center coil<br />

TS72 = 2 sensors center coil<br />

TS76 = 6 sensors, (2) on each coil<br />

TS8 = 1 sensor center coil<br />

TS82 = 2 sensors center coil<br />

TS86 = 6 sensors, (2) on each coil<br />

TS0 = 1 sensor center coil<br />

TS02 = 2 sensors center coil<br />

TS06 = 6 sensors, (2) on each coil<br />

a Contact Sales Office for pricing.<br />

ES2<br />

Common Mode:<br />

Transverse Mode:<br />

100dB: Between 60 Hz – 1 kHz 10dB: @ 10kHz<br />

90 dB: Between 1 kHz – 10 kHz 20dB: @ 100 kHz<br />

80dB: Between 10 kHz – 1000 kHz 40db: @ 1000 kHz<br />

8-20<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Warehouse Stock Transformers<br />

Warehouse Stock<br />

Revised on 04/17/17<br />

Selection<br />

Buck-Boost Application<br />

Description and Selection<br />

The Buck-Boost Transformer has four<br />

separate windings, two-windings in<br />

the primary and two-windings in the<br />

secondary. The unit is designed for use<br />

as an isolation (or insulating) transformer<br />

or as an autotransformer. As an autotransformer<br />

the unit can be connected<br />

to Buck (decrease) or Boost (increase)<br />

a supply voltage. When connected in<br />

either the Buck or Boost mode, the unit<br />

is no longer an isolation (or insulating)<br />

transformer but is an autotransformer.<br />

Units are designed for 60Hz applications<br />

(50Hz units available upon request).<br />

Autotransformers are more economical<br />

and physically smaller than equivalent twowinding<br />

transformers and are designed to<br />

carry the same function as two-winding<br />

transformers, with the exception of isolating<br />

two circuits. Since autotransformers may<br />

transmit line disturbances directly, they may<br />

be prohibited in some areas by local building<br />

codes. Before applying them, care should<br />

be taken to assure that they are acceptable<br />

according to local code.<br />

NOTE: Autotransformers are not used in<br />

closed delta connections as they introduce<br />

into the circuit a phase shift which makes<br />

them uneconomical.<br />

As isolation (or insulating) transformers<br />

these units can accommodate a high voltage<br />

of 120, 240 or 480 volts. For units<br />

with two 12 volt secondaries, two 16 volt<br />

secondaries, or two 24 volt secondaries, the<br />

output can be wired for either secondary<br />

voltage, or for 3-wire secondary. The unit is<br />

rated (kVA) as any conventional transformer.<br />

Operation<br />

Electrical and electronic equipment is<br />

designed to operate on a standard supply<br />

voltage. When the supply voltage is constantly<br />

too high or too low, (usually greater<br />

than ± 5%), the equipment fails to operate<br />

at maximum efficiency. A Buck-Boost<br />

transformer is a simple and economical<br />

means of correcting this off-standard<br />

voltage up to ± 20%. A Buck-Boost<br />

transformer will NOT, however, stabilize<br />

a fluctuating voltage. Buck-Boost<br />

transformers are suitable for use in a three<br />

phase autotransformer bank in either<br />

direction to supply 3-wire loads. They are<br />

also suitable for use in a three phase<br />

autotransformer bank which provides a<br />

neutral return for unbalanced current. They<br />

are NOT suitable for use in a three phase<br />

autotransformer bank to supply a 4-wire<br />

unbalanced load when the source is a<br />

3-wire circuit.<br />

Construction<br />

Buck-Boost Transformers are contained<br />

within a NEMA 3R, non-ventilated weatherproof<br />

enclosure. Wiring compartments<br />

are located at the bottom. Core and coil<br />

assemblies are encapsulated. Isolation (or<br />

insulating) system temperature is 130° C<br />

and the widing temperature rise is 95° C for<br />

units up through 1 kVA. Isolation (or insulating)<br />

system temperature is 180° C and the<br />

winding temperature rise is 135° C for units<br />

1.5 kVA and above.<br />

How To Select The Proper<br />

Transformer<br />

To select the proper Transformer for Buck-<br />

Boost applications, determine:<br />

1. Input line voltage — The voltage that you<br />

want to buck (decrease) or boost<br />

(increase). This can be found by<br />

measuring the supply line voltage with a<br />

voltmeter.<br />

2. Load voltage — The voltage at which<br />

your equipment is designed to operate.<br />

This is listed on the nameplate of the load<br />

equipment.<br />

3. Load kVA or Load Amps — You do not<br />

need to know both — one or the other is<br />

sufficient for selection purposes. This<br />

information usually can be found on the<br />

nameplate of the equipment that you<br />

want to operate.<br />

4. Number of phases — Single or three<br />

phase line and load should match<br />

because a transformer is not capable of<br />

converting single to three phase. It is<br />

however a common application to make<br />

a single phase transformer connection<br />

from a three phase supply by use of two<br />

legs of the three phase supply circuit.<br />

Care must always be taken not to overload<br />

the leg of the three phase supply.<br />

This is particularly true in a Buck-Boost<br />

application because the supply must<br />

provide for the load kVA, not just the<br />

nameplate rating of the Buck-Boost<br />

transformer.<br />

5. Frequency — The supply line frequency<br />

must be the same as the frequency of<br />

the equipment to be operated — either<br />

50 or 60 cycles.<br />

How To Use Selection Charts<br />

1. Choose the selection table with the<br />

correct number of phases for single or<br />

three phase applications.<br />

2. Line/Load voltage combinations are listed<br />

across the top of the selection table.<br />

Select a line/load voltage combination<br />

which comes closest to matching your<br />

applications.<br />

3. Follow the selected column down until<br />

you find either the kVA or load amps of<br />

your application. If you do not find the<br />

exact value, go on the next highest rating.<br />

4. Now follow across the table to the far lefthand<br />

side to find the catalog number and<br />

the kVA of the transformer you need.<br />

5. Follow the column of your line/load voltage<br />

to the bottom to find the connection<br />

diagram for this application.<br />

NOTE: Connection diagrams show lowvoltage<br />

and high-voltage connection<br />

terminals. Either can be input or output<br />

depending on Buck or Boost application.<br />

6. In the case of three phase loads either<br />

two or three single phase transformers<br />

are required as indicated in the “quantity<br />

required” line at the bottom of the table.<br />

The selection is dependent on whether a<br />

Wye connected bank of three transformers<br />

with a neutral is required or whether<br />

an open Delta connected bank of two<br />

ransformers for a Delta connected load<br />

will be suitable.<br />

7. For line/load voltage not listed on the<br />

selection tables, use the pair listed on the<br />

table that is slightly above your application<br />

for reference. Then apply the first<br />

formula at the bottom of the table to<br />

determine “new” output voltage. The<br />

new kVA rating can be found using the<br />

second formula.<br />

8 TRANSFORMERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 8-21


Warehouse Stock Transformers<br />

Buck-Boost<br />

Selection<br />

120 @ 240 Volts Primary — 12/24 Volts Secondary, 60 Hz, No Taps, Wall Mounted<br />

Single Phase — Table 1 Boosting Bucking<br />

Catalog Line Voltage<br />

Number* (Available)<br />

96 100 105 109 189 208 215 220 125 132 229 245 250 252<br />

Insulating<br />

Load Voltage<br />

Transformer<br />

(Output)<br />

Rating<br />

115 120 115 120 208 229 237 242 114 120 208 222 227 240<br />

050BB1224J kVA .24 .25 .50 .50 .43 .48 .49 .50 .52 .55 .48 .51 .52 1.05<br />

.050 kVA Load Amps 2.08 2.08 4.17 4.17 2.08 2.08 2.08 2.08 4.59 4.59 2.29 2.29 2.29 4.38<br />

100BB1224J kVA .48 .50 .96 1.00 .87 .95 .99 1.01 1.04 1.10 .95 1.02 1.04 2.10<br />

.100 kVA Load Amps 4.17 4.17 8.33 8.33 4.17 4.17 4.17 4.17 9.16 9.16 4.58 4.58 4.58 8.75<br />

150BB1224J kVA .72 .75 1.44 1.50 1.30 1.43 1.48 1.51 1.55 1.65 1.43 1.53 1.56 3.15<br />

.150 kVA Load Amps 6.25 6.25 12.50 12.50 6.25 6.25 6.25 6.25 13.75 13.75 6.88 6.88 6.88 13.13<br />

205BB1224J kVA 1.19 1.25 2.40 2.50 2.17 2.38 2.47 2.52 2.60 2.75 2.38 2.54 2.60 5.25<br />

.250 kVA Load Amps 10.42 10.42 20.83 20.83 10.42 10.42 10.42 10.42 22.92 22.92 11.46 11.46 11.46 21.88<br />

505BB1224J kVA 2.37 2.50 4.80 5.00 4.33 4.77 4.94 5.04 5.18 5.50 4.77 5.09 5.20 10.50<br />

.500 kVA Load Amps 20.83 20.83 41.67 41.67 20.83 20.83 20.83 20.83 45.83 45.83 22.92 22.92 22.92 43.75<br />

705BB1224J kVA 3.56 3.75 7.19 7.50 6.50 7.15 7.41 7.56 7.77 8.25 7.15 7.63 7.80 15.75<br />

.750 kVA Load Amps 31.25 31.25 62.50 62.50 31.25 31.25 31.25 31.25 68.75 68.75 34.38 34.38 34.38 65.63<br />

1BB1224J kVA 4.75 5.00 9.58 10.00 8.67 9.53 9.88 10.08 10.36 11.00 9.53 10.17 10.40 21.00<br />

1.00 kVA Load Amps 41.67 41.67 83.33 83.33 41.67 41.67 41.67 41.67 91.66 91.66 45.83 45.83 45.83 87.50<br />

105BB1224J kVA 7.13 7.50 14.38 15.00 13.00 14.30 14.81 15.13 15.54 16.50 14.30 15.26 15.61 31.50<br />

1.50 kVA Load Amps 62.50 62.50 125.00 125.00 62.50 62.50 62.50 62.50 137.50 137.50 68.75 68.75 68.75 131.25<br />

2BB1224J kVA 9.50 10.00 19.17 20.00 17.33 19.07 19.75 20.17 20.72 22.00 19.07 20.35 20.81 42.00<br />

2.00 kVA Load Amps 83.33 83.33 166.66 166.66 83.33 83.33 83.33 83.33 183.33 183.33 91.66 91.66 91.66 175.00<br />

3BB1224J kVA 14.25 15.00 28.75 30.00 26.00 28.60 29.63 30.25 31.08 33.00 28.60 30.53 31.21 63.00<br />

3.00 kVA Load Amps 125.00 125.00 250.00 250.00 125.00 125.00 125.00 125.00 275.00 275.00 137.50 137.50 137.50 262.50<br />

5BB1224J kVA 23.75 25.00 47.92 50.00 43.33 47.67 49.37 50.42 51.79 55.00 47.67 50.88 52.02 105.00<br />

5.00 kVA Load Amps 208.33 208.33 416.66 416.66 208.33 208.33 208.33 208.33 458.33 458.33 229.17 229.17 229.17 437.50<br />

Connection Diagram (pg. 8-25) 2 2 1 1 4 4 4 4 4 1 4 4 4 3<br />

8<br />

TRANSFORMERS<br />

Three Phase — Table 2 Boosting Bucking<br />

Catalog Line Voltage 189Y/ 195Y/ 200Y/ 208Y/ 416Y/ 416Y/<br />

Number* (Available) 109 113 115 120 240 240<br />

189 208 220 218 229 250 255 264<br />

Insulating<br />

Load Voltage 208Y/ 234Y/ 240Y/ 229Y/ 458Y/ 437Y/<br />

Transformer<br />

(Output) 120 135 139 132 264 252<br />

Rating<br />

208 229 242 208 208 227 232 240<br />

050BB1224J kVA 1.50 .84 .86 1.65 1.65 3.15 .75 .83 .87 1.58 .83 .90 .92 .95<br />

.050 kVA Load Amps 4.17 2.08 2.08 4.17 2.08 4.17 2.08 2.08 2.08 4.39 2.29 2.29 2.29 2.29<br />

100BB1224J kVA 3.00 1.69 1.73 3.30 3.30 6.29 1.50 1.65 1.75 3.15 1.65 1.80 1.84 1.90<br />

.100 kVA Load Amps 8.33 4.17 4.17 8.33 4.17 8.33 4.17 4.17 4.17 8.75 4.58 4.58 4.58 4.58<br />

150BB1224J kVA 4.50 2.54 2.60 4.96 4.96 9.44 2.26 2.48 2.62 4.73 2.48 2.71 2.76 2.86<br />

.150 kVA Load Amps 12.50 6.25 6.25 12.50 6.25 12.50 6.25 6.25 6.25 13.13 6.88 6.88 6.88 6.88<br />

205BB1224J kVA 7.50 4.22 4.33 8.30 8.25 15.75 3.75 4.13 4.37 7.88 4.13 4.50 4.61 4.76<br />

.250 kVA Load Amps 20.83 10.42 10.42 20.83 10.42 20.83 10.42 10.42 10.42 21.88 11.46 11.46 11.46 11.46<br />

505BB1224J kVA 15.01 8.44 8.66 16.60 16.50 31.50 7.50 8.26 8.73 15.76 8.26 9.01 9.21 9.53<br />

.500 kVA Load Amps 41.67 20.83 20.83 41.67 20.83 41.67 20.83 20.83 20.83 43.75 22.92 22.92 22.92 22.92<br />

705BB1224J kVA 22.52 12.67 12.99 24.90 24.75 47.25 11.26 12.39 13.10 23.64 12.39 13.52 13.82 14.29<br />

.750 kVA Load Amps 62.50 31.25 31.25 62.50 31.25 62.50 31.25 31.25 31.25 65.63 34.38 34.38 34.38 34.38<br />

1BB1224J kVA 30.02 16.89 17.32 33.20 33.00 63.00 15.01 16.51 17.47 31.52 16.51 18.02 18.42 19.05<br />

1.00 kVA Load Amps 83.33 41.67 41.67 83.33 41.67 83.33 41.67 41.67 41.67 87.50 45.83 45.83 45.83 45.53<br />

105BB1224J kVA 45.03 25.33 25.98 49.80 49.50 94.50 22.52 24.77 26.20 47.28 24.77 27.03 27.63 28.53<br />

1.50 kVA Load Amps 125.00 62.50 62.50 125.00 62.50 125.00 62.50 62.50 62.50 131.25 68.75 68.75 68.75 68.75<br />

2BB1224J kVA 60.06 33.77 34.64 66.40 66.00 126.00 30.02 33.03 34.93 63.05 33.03 36.04 36.84 38.11<br />

2.00 kVA Load Amps 166.67 83.33 83.33 166.67 83.33 166.66 83.33 83.33 83.33 175.00 91.67 91.67 91.67 91.67<br />

3BB1224J kVA 90.07 50.66 51.96 99.59 99.00 189.00 45.03 49.54 52.39 94.57 49.54 54.06 55.25 57.16<br />

3.00 kVA Load Amps 250.00 125.00 125.00 250.00 125.00 250.00 125.00 125.00 125.00 262.50 137.50 137.50 137.50 137.50<br />

5BB1224J kVA 150.11 84.44 86.60 165.99 165.00 318.00 75.05 82.56 87.32 157.62 82.56 90.10 92.09 95.26<br />

5.00 kVA Load Amps 416.67 208.33 208.33 416.67 208.33 416.66 208.33 208.33 208.33 437.50 229.17 229.17 229.17 229.17<br />

Quantity Required 3 3 3 3 3 3 2 2 2 2 2 2 2 2<br />

Connection Diagram (pg. 8-25) 5 6 6 5 8 7 12 12 12 11 12 12 12 12<br />

* All Buck-Boost transformers listed<br />

are available for immediate shipment.<br />

• Output voltage for lower input voltage can be found by:<br />

Rated Output Voltage<br />

@ Input Actual Voltage = Output New Voltage.<br />

Rated Input Voltage<br />

• Output kVA available at reduced input voltage can be found by:<br />

Actual Input Voltage<br />

@ Output kVA = New kVA Rating.<br />

Rated Input Voltage<br />

• Inputs and outputs may be reversed<br />

without affecting kVA capacity. See<br />

note on page 8-25<br />

8-22<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Warehouse Stock Transformers<br />

Buck-Boost<br />

Revised on 04/17/17<br />

Selection<br />

120 @ 240 Volts Primary — 16/32 Volts Secondary, 60 Hz, No Taps, Wall Mounted<br />

Single Phase — Table 3 Boosting Bucking<br />

Catalog Line Voltage<br />

Number* (Available)<br />

95 100 105 208 215 215 220 225 135 240 240 245 250 255<br />

Insulating<br />

Load Voltage<br />

Transformer<br />

(Output)<br />

Rating<br />

120 113 119 236 244 229 235 240 120 212 225 230 234 239<br />

050BB1632J kVA .19 .36 .37 .37 .38 .72 .73 .73 .42 .37 .75 .77 .78 .80<br />

.050 kVA Load Amps 1.56 3.12 3.12 1.56 1.56 3.12 3.12 3.12 3.54 1.77 3.33 3.33 3.33 3.33<br />

100BB1632J kVA .38 .72 .74 .74 .76 1.44 1.46 1.50 .84 .74 1.50 1.54 1.56 1.60<br />

.100 kVA Load Amps 3.13 6.25 6.25 3.13 3.13 6.25 6.25 6.25 7.09 3.54 6.66 6.66 6.66 6.66<br />

150BB1632J kVA .56 1.06 1.12 1.12 1.14 2.16 2.20 2.26 1.26 1.10 2.26 2.30 2.34 2.40<br />

.150 kVA Load Amps 4.69 9.38 9.38 4.69 4.69 9.38 9.38 9.38 10.64 5.30 10.02 10.02 10.02 10.02<br />

205BB1632J kVA .94 1.78 1.86 1.88 1.91 3.59 3.67 3.75 2.11 1.84 3.75 3.83 3.90 3.98<br />

.250 kVA Load Amps 7.81 15.63 15.63 7.81 7.81 15.63 15.63 15.63 17.71 8.85 16.67 16.67 16.67 16.67<br />

505BB1632J kVA 1.88 3.56 3.72 3.75 3.81 7.19 7.34 7.50 4.21 3.68 7.50 7.67 7.80 7.97<br />

.500 kVA Load Amps 15.63 31.25 31.25 15.63 15.63 31.25 31.25 31.25 35.42 17.71 33.33 33.33 33.33 33.33<br />

705BB1632J kVA 2.81 5.34 5.58 5.63 5.72 10.78 11.02 11.25 6.32 5.53 11.25 11.50 11.70 11.95<br />

.750 kVA Load Amps 23.44 46.88 46.88 23.44 23.44 46.88 46.88 46.88 53.13 26.56 50.00 50.00 50.00 50.00<br />

1BB1632J kVA 3.75 7.13 7.44 7.50 7.63 14.38 14.69 15.00 8.43 7.37 15.00 15.33 15.60 15.93<br />

1.00 kVA Load Amps 31.25 62.50 62.50 31.25 31.25 62.50 62.50 62.50 70.83 35.42 66.67 66.67 66.67 66.67<br />

105BB1632J kVA 5.63 10.69 11.16 11.25 11.44 21.56 22.03 22.50 12.64 11.05 22.50 23.00 23.40 23.90<br />

1.50 kVA Load Amps 43.90 93.80 93.80 46.90 46.90 93.80 93.80 93.80 106.30 53.10 100.00 100.00 100.00 100.00<br />

2BB1632J kVA 7.50 14.25 14.88 15.00 15.25 28.75 29.38 30.00 16.86 14.73 30.00 30.67 31.20 31.87<br />

2.00 kVA Load Amps 62.50 125.00 125.00 62.50 62.50 125.00 125.00 125.00 141.70 70.80 133.30 133.30 133.30 133.30<br />

3BB1632J kVA 11.25 21.38 22.31 22.50 22.88 43.13 44.06 45.00 25.29 22.10 45.00 46.00 46.80 47.80<br />

3.00 kVA Load Amps 93.80 187.50 187.50 93.80 93.80 187.50 187.50 187.50 212.50 106.30 200.00 200.00 200.00 200.00<br />

5BB1632J kVA 18.75 35.63 37.19 37.50 38.13 71.88 73.44 75.00 42.15 36.83 75.00 76.67 78.00 79.67<br />

5.00 kVA Load Amps 156.30 312.50 312.50 156.30 156.30 312.50 312.50 312.50 354.20 177.10 333.30 333.30 333.30 333.30<br />

Connection Diagram (pg. 8-25) 2 1 1 4 4 3 3 3 1 4 3 3 3 3<br />

Three Phase — Table 4 Boosting Bucking<br />

Catalog Line Voltage 183Y/ 208Y/<br />

Number* (Available) 106 120<br />

195 208 225 240 245 250 256 265 272<br />

Insulating<br />

Load Voltage 208Y/ 236Y/<br />

Transformer<br />

(Output) 120 136<br />

Rating<br />

208 236 240 208 230 234 240 234 240<br />

050BB1632J kVA 1.13 1.28 1.13 .62 1.30 .56 1.33 1.35 1.39 .72 .74<br />

.050 kVA Load Amps 3.13 3.13 3.13 1.56 3.13 1.56 3.34 3.34 3.34 1.77 1.77<br />

100BB1632J kVA 2.25 2.55 2.25 1.30 2.60 1.13 2.66 2.70 2.77 1.44 1.48<br />

.100 kVA Load Amps 6.25 6.25 6.25 3.13 6.25 3.13 6.67 6.67 6.67 3.55 3.55<br />

150BB1632J kVA 3.38 3.83 3.38 1.95 3.90 1.69 3.98 4.05 4.16 2.15 2.21<br />

.150 kVA Load Amps 9.38 9.38 9.38 4.69 9.38 4.69 10.00 10.00 10.00 5.31 5.31<br />

205BB1632J kVA 5.63 6.39 5.63 3.17 6.50 2.81 6.64 6.76 6.93 3.59 3.68<br />

.250 kVA Load Amps 15.63 15.63 15.63 7.81 15.63 7.81 16.67 16.67 16.67 8.85 8.85<br />

505BB1632J kVA 11.26 12.77 11.26 6.33 12.99 5.63 13.28 13.50 13.86 7.17 7.36<br />

.500 kVA Load Amps 31.25 31.26 31.25 15.63 31.25 15.63 33.33 33.33 33.33 17.69 17.71<br />

705BB1632J kVA 16.89 19.16 16.89 9.50 19.49 8.44 19.92 20.26 20.78 10.76 11.04<br />

.750 kVA Load Amps 46.88 46.88 46.88 23.44 46.88 23.44 50.00 50.00 50.00 26.54 26.56<br />

1BB1632J kVA 22.52 25.55 22.52 12.67 25.98 11.26 26.56 27.02 27.71 14.34 14.72<br />

1.00 kVA Load Amps 62.50 62.50 62.50 31.25 62.50 31.25 66.67 66.67 66.67 35.39 35.42<br />

105BB1632J kVA 33.77 38.32 33.77 19.00 38.97 16.89 39.84 40.53 41.57 21.52 22.08<br />

1.50 kVA Load Amps 93.75 93.75 93.75 46.88 93.75 46.88 100.00 100.00 100.00 53.08 53.13<br />

2BB1632J kVA 45.03 51.10 46.03 25.33 51.96 22.52 53.11 54.04 55.43 28.69 29.44<br />

2.00 kVA Load Amps 125.00 125.00 125.00 62.50 125.00 62.50 133.33 133.33 133.33 70.78 70.83<br />

3BB1632J kVA 67.55 76.64 67.55 38.00 77.94 33.77 79.67 81.06 83.14 43.03 44.17<br />

3.00 kVA Load Amps 187.50 187.50 187.50 93.75 187.50 93.75 200.00 200.00 200.00 106.17 106.25<br />

5BB1632J kVA 112.58 127.74 112.58 63.33 129.90 56.29 132.79 135.09 138.56 71.72 73.61<br />

5.00 kVA Load Amps 312.50 312.50 312.50 156.25 312.50 156.25 333.33 333.33 333.33 176.95 177.08<br />

Quantity Required 3 3 2 2 2 2 2 2 2 2 2<br />

Connection Diagram (pg. 8-25) 5 5 11 12 11 12 11 11 11 12 12<br />

8 TRANSFORMERS<br />

* All Buck-Boost transformers listed<br />

are available for immediate shipment.<br />

• Output voltage for lower input voltage can be found by:<br />

Rated Output Voltage<br />

@ Input Actual Voltage = Output New Voltage.<br />

Rated Input Voltage<br />

• Output kVA available at reduced input voltage can be found by:<br />

Actual Input Voltage<br />

@ Output kVA = New kVA Rating.<br />

Rated Input Voltage<br />

• Inputs and outputs may be reversed<br />

without affecting kVA capacity. See<br />

note on page 8-25.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 8-23


Warehouse Stock Transformers<br />

Buck-Boost<br />

Selection<br />

240 @ 480 Volts Primary — 24/48 Volts Secondary, 60 Hz, No Taps, Wall Mounted<br />

Single Phase — Table 5 Boosting Bucking<br />

Catalog Line Voltage<br />

Number* (Available)<br />

230 380 416 425 430 435 440 450 450 460 277 480 480 504<br />

Insulating<br />

Load Voltage<br />

Transformer<br />

(Output)<br />

Rating<br />

276 418 458 468 473 457 462 495 472 483 231 436 457 480<br />

050BB2448J kVA .29 .44 .48 .49 .49 .95 .96 .52 .98 1.01 .29 .50 1.00 1.05<br />

.050 kVA Load Amps 1.04 1.04 1.04 1.04 1.04 2.08 2.08 1.04 2.08 2.08 1.25 1.15 2.19 2.19<br />

100BB2448J kVA .58 .87 .95 .97 .99 1.90 1.93 1.03 1.97 2.01 .58 1.00 2.00 2.10<br />

.100 kVA Load Amps 2.08 2.08 2.08 2.08 2.08 4.17 4.17 2.08 4.17 4.17 2.50 2.29 4.38 4.38<br />

150BB2448J kVA .86 1.31 1.43 1.46 1.48 2.86 2.89 1.55 2.95 3.02 .86 1.50 3.00 3.15<br />

.150 kVA Load Amps 3.13 3.13 3.13 3.13 3.13 6.25 6.25 3.13 6.25 6.25 3.75 3.44 6.56 6.56<br />

205BB2448J kVA 1.44 2.18 2.38 2.43 2.46 4.76 4.81 2.58 4.92 5.03 1.44 2.50 5.00 5.25<br />

.250 kVA Load Amps 5.21 5.21 5.21 5.21 5.21 5.21 10.42 5.21 10.42 10.42 6.25 5.73 10.94 10.94<br />

505BB2448J kVA 2.88 4.35 4.77 4.87 4.93 9.52 9.62 5.16 9.83 10.06 2.88 5.00 10.00 10.50<br />

.500 kVA Load Amps 10.42 10.42 10.42 10.42 10.42 20.83 20.83 10.42 20.83 20.83 12.50 11.46 21.88 21.88<br />

705BB2448J kVA 4.31 6.53 7.15 7.30 7.39 14.28 14.44 7.73 14.75 15.09 4.31 7.49 15.00 15.75<br />

.750 kVA Load Amps 15.63 15.63 15.62 15.63 15.63 31.25 31.25 15.63 31.25 31.25 18.75 17.19 32.81 32.81<br />

1BB2448J kVA 5.75 8.71 9.53 9.74 9.85 19.04 19.25 10.31 19.67 20.13 5.75 9.99 20.00 21.00<br />

1.00 kVA Load Amps 20.83 20.83 20.83 20.83 20.83 41.67 41.67 20.83 41.67 41.67 25.00 22.92 43.75 43.75<br />

105BB2448J kVA 8.63 13.06 14.30 14.61 14.78 28.56 28.88 15.47 29.50 30.19 8.63 14.99 30.00 31.50<br />

1.50 kVA Load Amps 31.25 31.25 31.25 31.25 31.25 62.50 62.50 31.25 62.50 62.50 37.50 34.38 65.63 65.63<br />

2BB2448J kVA 11.50 17.42 19.07 19.48 19.71 38.08 38.50 20.63 39.33 40.25 11.50 19.98 40.00 42.00<br />

2.00 kVA Load Amps 41.67 41.67 41.67 41.67 41.67 83.33 83.33 41.67 83.33 83.33 50.00 45.83 87.50 87.50<br />

3BB2448J kVA 17.25 26.13 28.60 29.22 29.56 57.13 57.75 30.94 59.00 60.38 17.25 29.98 60.00 63.00<br />

3.00 kVA Load Amps 62.50 62.50 62.50 62.50 62.50 125.00 125.00 62.50 125.00 125.00 75.00 68.80 131.25 131.25<br />

5BB2448J kVA 28.75 43.54 47.67 48.70 49.30 95.20 96.20 51.56 98.30 100.60 28.80 50.00 100.00 105.00<br />

5.00 kVA Load Amps 104.17 104.17 104.17 104.17 104.20 208.30 208.30 104.17 208.30 208.30 125.00 114.60 218.75 218.75<br />

Connection Diagram (pg. 8-25) 2 4 4 4 4 3 3 4 3 3 2 4 3 3<br />

8<br />

TRANSFORMERS<br />

Three Phase — Table 6 Boosting Bucking<br />

Catalog Line Voltage 399Y/<br />

Number* (Available) 230<br />

380 430 440 460 460 480 480 440 440 460 460 480 480 500 500<br />

Insulating<br />

Load Voltage 480Y/<br />

Transformer<br />

(Output) 277<br />

Rating<br />

418 473 462 506 483 528 504 400 419 438 418 457 436 455 476<br />

050BB2448J kVA .86 .75 .85 1.66 .91 1.74 .95 1.82 .79 1.58 1.66 .83 1.73 .86 .90 1.80<br />

.050 kVA Load Amps 1.04 1.04 1.04 2.08 1.04 2.08 1.04 2.08 1.14 2.18 2.18 1.14 2.18 1.14 1.14 2.19<br />

100BB2448J kVA 1.73 1.51 1.70 3.33 1.82 3.48 1.90 3.63 1.59 3.17 3.31 1.66 3.46 1.73 1.80 3.61<br />

.100 kVA Load Amps 2.08 2.08 2.08 4.16 2.08 4.16 2.08 4.16 2.29 4.37 4.37 2.29 4.37 2.29 2.29 4.38<br />

150BB2448J kVA 2.60 2.26 2.56 4.99 2.73 5.22 2.85 5.45 2.38 4.75 4.97 2.48 5.19 2.59 2.70 5.41<br />

.150 kVA Load Amps 3.12 3.13 3.12 6.24 3.12 6.25 3.12 6.24 3.43 6.55 6.55 3.43 6.55 3.43 3.43 6.56<br />

205BB2448J kVA 4.33 3.77 4.26 8.32 4.56 8.70 4.76 9.08 3.96 7.92 8.28 4.14 8.64 4.32 4.51 9.02<br />

.250 kVA Load Amps 5.20 5.21 5.20 10.40 5.20 10.40 5.20 10.40 5.72 10.92 10.92 5.72 10.92 5.72 5.72 10.94<br />

505BB2448J kVA 8.60 7.54 8.52 16.64 9.11 17.40 9.51 18.16 7.93 15.85 16.57 8.28 17.29 8.64 9.02 18.04<br />

.500 kVA Load Amps 10.40 10.42 10.40 20.80 10.40 20.80 10.40 20.80 11.44 21.84 21.84 11.44 21.84 11.44 11.44 21.88<br />

705BB2448J kVA 12.90 11.31 12.77 24.97 13.67 26.10 14.27 27.24 11.89 23.77 24.85 12.42 25.93 12.96 13.52 27.06<br />

.750 kVA Load Amps 15.60 15.63 15.60 31.20 15.60 31.20 15.60 31.20 17.16 32.76 32.76 17.16 32.76 17.16 17.16 32.81<br />

1BB2448J kVA 17.30 15.08 17.03 33.29 18.23 34.80 19.02 36.31 15.85 31.70 33.14 16.57 34.57 17.28 18.03 36.08<br />

1.00 kVA Load Amps 20.80 20.83 20.80 41.60 20.80 41.60 20.80 41.60 22.88 43.68 43.68 22.88 43.68 22.88 22.88 43.75<br />

105BB2448J kVA 25.90 22.62 25.55 49.93 27.34 52.50 28.53 54.47 23.78 47.55 49.71 24.85 51.86 25.92 27.05 54.13<br />

1.50 kVA Load Amps 31.20 31.25 31.20 62.40 31.20 62.40 31.20 62.40 34.32 65.52 65.52 34.32 65.62 34.32 34.32 65.63<br />

2BB2448J kVA 34.60 30.17 34.07 66.58 36.46 69.60 38.04 72.63 31.70 63.40 66.27 33.13 69.15 34.56 36.06 72.17<br />

2.00 kVA Load Amps 41.60 41.67 41.60 83.20 41.60 83.20 41.60 83.20 45.76 87.36 87.36 45.76 87.36 45.76 45.76 87.50<br />

3BB2448J kVA 52.00 45.25 51.18 100.03 54.69 104.57 57.07 109.12 47.63 95.25 99.57 49.77 103.89 51.92 54.18 108.25<br />

3.00 kVA Load Amps 62.50 62.50 62.50 125.00 62.50 125.00 62.50 125.00 68.75 131.25 131.25 68.75 131.25 68.75 68.75 131.25<br />

5BB2448J kVA 86.10 75.42 85.17 166.44 91.15 174.01 95.11 181.57 79.26 158.50 165.69 82.83 172.87 86.39 90.16 180.42<br />

5.00 kVA Load Amps 104.00 104.17 104.00 208.00 104.00 208.00 104.00 208.00 114.40 218.40 218.40 114.40 218.40 114.40 114.40 218.75<br />

Quantity Required 3 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2<br />

Connection Diagram (pg. 8-25) 6 12 12 11 12 11 12 11 12 11 11 12 11 12 12 11<br />

* All Buck-Boost transformers listed<br />

are available for immediate shipment.<br />

• Output voltage for lower input can be found by:<br />

Rated Output Voltage<br />

@ Input Actual Voltage = Output New Voltage.<br />

Rated Input Voltage<br />

• Output kVA available at reduced input voltage can be found by:<br />

Actual Input Voltage<br />

@ Output kVA = New kVA Rating.<br />

Rated Input Voltage<br />

• Inputs and outputs may be reversed<br />

without affecting kVA capacity. See<br />

note on page 8-25.<br />

8-24<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Buck-Boost Transformers<br />

Single Phase, Three Phase<br />

Typical Connection Diagrams<br />

If you are using this unit as an auto<br />

transformer to buck (lower) or boost<br />

(raise) the voltage by a 12 to 48 volts use<br />

the information on pages 8-22 to 8-24 to<br />

select the proper wiring diagram.<br />

Note: HV= Higher Voltage, LV= Lower<br />

Voltage when bucking and boosting.<br />

If you are using this unit as an isolation<br />

transformer with a primary of 120 or<br />

240 or 480 volts and the secondary of<br />

12/24, 16/32, or 24/48 (depending on the<br />

model) use the wiring diagram located<br />

on the inside of the cover to the wiring<br />

compartment.<br />

Low-voltage Applications:<br />

By using the “Standard Step-down<br />

Application” diagram at left, buck boost<br />

transformers will convert 120V or 240V to<br />

12, 24, 16 or 32 volts and 240V or 480V to<br />

24 or 48 volts without affecting the nameplate<br />

kVA rating of the transformer. Buck<br />

boost transformers used in this type of<br />

application will become isolation or insulating<br />

type transformers.<br />

Single Phase<br />

Diagram 1<br />

Diagram 2<br />

(Standard Step-down Application)*<br />

Diagram 3<br />

Diagram 4<br />

8 TRANSFORMERS<br />

Note:<br />

•Inputs and Outputs may be reversed; kVA capacity<br />

remains constant. Exception: Cannot use 3-wire input<br />

with 4-wire output to form a neutral and does not<br />

apply to standard step-down applications.<br />

•Refer to NEC 450-4 for overcurrent protection of an<br />

autotransformer.<br />

•All applications are suitable for 60Hz only,<br />

contact factory for 50Hz information.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 8-25


Revised on 04/30/17<br />

Buck-Boost Transformers<br />

Single Phase, Three Phase<br />

Typical Connection Diagrams<br />

Three Phase<br />

Note: Contact sales office for diagrams applicable to “J” suffix.<br />

Diagram 5 a<br />

Diagram 6 a<br />

Diagram 7 a Diagram 8 a<br />

Diagram 9<br />

Diagram 11 b<br />

TRANSFORMERS<br />

8<br />

Diagram 12 b<br />

a These diagrams can only be used when the source is a<br />

4-wire supply.<br />

b The neutral XO should not be used when the source is a<br />

three wire supply.<br />

Note:<br />

•Inputs and Outputs may be reversed; kVA capacity<br />

remains constant. Exception: Cannot use 3-wire input<br />

with 4-wire output to form a neutral and does not<br />

apply to standard step-down applications.<br />

• Refer to NEC 450-4 for overcurrent protection of an<br />

autotransformer.<br />

• All applications are suitable for 60Hz only,<br />

contact factory for 50Hz information.<br />

8-26<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Warehouse Stock Transformers<br />

Accessories and Details<br />

Revised on 05/31/18<br />

Selection<br />

Drip Shield/Weather Shield Kits for<br />

Ventilated Transformers ab<br />

Drip shields are integral to enclosure for Series H<br />

transformers and all DOE 2016 Series J transformers.<br />

Include DS option code to catalog number to include<br />

with single phase Series J transformers. Drip shield kits<br />

are available for field installation for Series J and other<br />

previously sold series transformers. Call factory for price<br />

and availability. See page 8-8 for additional information.<br />

Wall Mounting Brackets for<br />

Ventilated Transformers<br />

For Series H transformers, wall brackets are integral to the<br />

enclosure up to 30kVA and most 45kVA. A Wall Bracket Kit is<br />

available for 45kVA transformers that do not include wall brackets<br />

and for most 75kVA transformers. They should be ordered<br />

separately for field installation rather than including the W option<br />

in the catalog number. Series H wall brackets are not seismic<br />

certified. For Series J, include W option code for wall brackets to<br />

come with Series J transformers up to 75kVA or order separately<br />

for field installation. Call factory for price and availability.<br />

Terminal Lug Kits For Ventilated Transformers <br />

Catalog<br />

Number<br />

Single<br />

Phase<br />

kVA Sizes<br />

Three<br />

Phase<br />

kVA Sizes<br />

Primary<br />

Terminal Lug c<br />

Qty. d<br />

Range<br />

Secondary<br />

Terminal Lug c<br />

Qty. d<br />

Cable<br />

Range<br />

Primary<br />

Hardware Included<br />

Secondary<br />

Hardware Included<br />

Qty. Bolt Size Qty. Bolt Size<br />

TLK14Q 75, 100 — 4 #6-350 kcmil 8 #6-350 kcmil 4 3/8 x 1 1/2 8 3/8 x 1 1/2<br />

TLK15Q 167.5 — 8 #6-350 kcmil 12 1/0-750 kcmil 8 3/8 x 1 1/2 12 1/2 x 1 1/2<br />

TLK34Q — 112.5 3 #6-350 kcmil 8 #6-350 kcmil 3 3/8 x 1 1/2 8 3/8 x 1 1/2<br />

TLK35Q — 150 3 #6-350 kcmil 8 1/0-750 kcmil 3 3/8 x 1 1/2 8 3/8 x 1 1/2<br />

TLK36Q — 225 6 #6-350 kcmil 16 #6-350 kcmil 6 3/8 x 1 1/2 16 3/8 x 1 1/2<br />

TLK37Q — 300 6 #6-350 kcmil 16 1/0-750 kcmil 6 3/8 x 1 1/2 16 1/2 x 1 1/2<br />

TLK38Q — 500 9 #6-350 kcmil 24 1/0-750 kcmil 9 3/8 x 1 1/2 24 1/2 x 1 1/2<br />

TLK39Q — 750 12 #6-350 kcmil 28 1/0-750 kcmil 12 3/8 x 1 1/2 28 1/2 x 1 1/2<br />

c May be used on “JST” suffix and “non JST” suffix transformers. Terminal lugs are screw type, lug connectors suitable<br />

for both copper and aluminum cable. All lugs are single barrel and suitable for cable ranges shown. 750kcmil lugs are<br />

capable of holding (2) 250kcmil cables in lieu of (1) 750kcmil cable. All lugs are rated 90˚C.<br />

d Lug kits contain quantity required for each kVA based NEC ampacities for cable range indicated. For cable sizes outside<br />

the range, hole size of terminal may not be the correct size to mount other lugs. Bolt size in Hardware included column<br />

provides indication of hole size.<br />

e Primary and secondary terminal lugs are included on<br />

most ventilated transformers. (15kVA - 75kVA 3PH &<br />

15kVA - 50kVA 1PH). Some 45 or 75kVA may not have<br />

secondary lugs depending on number and type of additional<br />

options. Call factory for confirmation.<br />

Standard Terminal Lug Offerings <br />

(Primary and Secondary) for Ventilated Transformers (150 Degree Rise - Series J only - Without a K rating)<br />

1-Phase<br />

3-Phase<br />

kVA 120/240V 208V 480V 600V kVA 120/240V 208V 480V 600V<br />

0-15 Contact customer support f 0-15 Contact customer support f<br />

15 #2/0-6 #14-2 #14-2 #14-2 15 #14-2 #14-2 #14-2 #14-2<br />

25 250MCM-6 250MCM-6 #14-2 #14-2 30 #2/0-6 #2/0-6 #14-2 #14-2<br />

37.5 350MCM-6 350MCM-6 #14-2 #14-2 45 250MCM-6 250MCM-6 #14-2 #14-2<br />

50 600MCM-2 600MCM-2 #2/0-6 #2/0-6 75 600MCM-2 350MCM-6 #2/0-6 #2/0-6<br />

>50 Contact customer support >75 Contact customer support<br />

Values listed above are for standard configurations. There may be slight variations depending on requirements. Contact Customer Support for special requirements. Encapsulated units<br />

less than or equal to 15kVA do not have lugs. Lead wires are provided.<br />

For Series H, see chart in Series H Addendum - Page H-17 Lug Pad sizes are not available except on cutsheets. Contact Customer Support for special requirements.<br />

Wall Bracket Kits for<br />

Series J DOE 2016 3 Phase Transformers<br />

Series J Wall Bracket Kits <br />

Temp Rise<br />

K Factor<br />

kVA 150C 115C 80C K1 K4 K13 K20<br />

15 TWB15J TWB15J TWB75J TWB15J TWB15J TWB75J TWB75J<br />

30 TWB75J TWB75J TWB75J TWB75J TWB75J TWB75J TWB75J<br />

45 TWB75J TWB75J NA TWB75J TWB75J NA NA<br />

75 TWB75J TWB75J NA TWB75J TWB75J NA NA<br />

Wall Bracket Kit not available for 75kVA with Copper Windings.<br />

See Wall Bracket/Drip Shield Table on Page 8-8 for availability information.<br />

Wall Bracket for Series J<br />

SIngle Phase Transformers<br />

Series J Wall Bracket Kits<br />

Temp Rise<br />

kVA 150C 115C 80C<br />

15 TWB15J TWB15J TWB75J<br />

25 TWB75J TWB75J TWB75J<br />

37.5 TWB75J TWB75J TWB75J<br />

50 TWB75J TWB75J TWB75J<br />

75 NA NA NA<br />

100 NA NA NA<br />

8 TRANSFORMERS<br />

a Series J Drip Shield Kits are available as a special order.<br />

Add “XD” to the catalog number.<br />

Product Category XFMR<br />

b UL Listed for indoor and outdoor use with<br />

dripshield installed.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 8-27


Transformers<br />

Notes<br />

TRANSFORMERS<br />

8<br />

8-28<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Digital Power & Thermal Monitoring Products<br />

SPEEDFAX TM<br />

Section<br />

c o n t e n t s<br />

SEM3T Thermal<br />

Monitoring System<br />

Selection and Application Guide<br />

New! Thermal Monitoring System – SEM3T<br />

Electrical Power Monitoring Software<br />

Power Distributions Solutions Introduction<br />

Power Monitoring Systems Overview 9-2<br />

Intelligent Metering and Control Devices 9-3<br />

Power Meters<br />

PAC2200 9-4<br />

PAC3120 9-5<br />

PAC3200T 9-6<br />

PAC3220 9-7<br />

PAC4200 9-8<br />

9410 9-9<br />

9810 9-10 – 9-11<br />

Enclosed Meters 9-12<br />

Branch Circuit Monitoring /SEM3 Embedded Metering 9-13 –9-20<br />

Enclosures for External Applications 9-21 – 9-22<br />

MD Meter – BACnet MSTP/IP standalone meter 9-23<br />

Low-voltage Current Transformers 9-24 – 9-25<br />

Thermal Monitoring Solution<br />

SEM3T 9-26 – 9-33<br />

Energy Management Software<br />

Powermanager Software 9-34<br />

WinPM.Net Software 9-35<br />

Application Engineering<br />

Digitalization for Smart Infrastructure 9-36<br />

Services 9-37<br />

Siemens recognizes that high performance facilities make for high performance<br />

business. Energy is the lifeline of your business, and better efficiency and<br />

sustainability can have a large positive impact on your bottom line.<br />

Energy Management and Control Systems from Siemens are complete enterprise<br />

solutions that help you manage the energy costs and availability of your business.<br />

With our advanced meters and controls, you can be sure to use only the energy you<br />

need, when you need it.<br />

Assembled Meter Enclosure<br />

Siemens Power Distribution Solutions contribute toward achieving LEED®<br />

certification and provides the needed energy metering data for federal/local<br />

government energy reductions programs.<br />

Power Meters<br />

Features and Benefits of Siemens Power Distribution Solutions:<br />

n Power Quality Reliability & Analysis<br />

n Utilities Cost Allocation & Billing<br />

n Utilities Usage Aggregation<br />

n Load Preservation<br />

n Equipment Monitoring<br />

n Facility Monitoring & Automation<br />

n Sequence of Event Recording<br />

n Preventative Maintenance<br />

n Electrical Asset Management<br />

Additional Products/Services<br />

n Branch Circuit Monitoring<br />

n Sub-Billing and Cost Allocation<br />

n Application Engineering<br />

n Services Agreements<br />

n Network/Communication<br />

Components<br />

n Integration with Existing<br />

n SCADA/BAS Systems<br />

n Incorporation of Third Party Devices<br />

9 POWER<br />

MONITORING<br />

Scan to connect<br />

online to the<br />

most up-todate<br />

version of<br />

this Section of<br />

SPEEDFAX.<br />

For Technical Assistance Contact: 1-800-333-7421<br />

Create Support Ticket Online:<br />

https://support.industry.siemens.com/my/WW/en/requests#createRequest<br />

PDS Request for Information / Request for Quote:<br />

www.usa.siemens.com/pds-request<br />

(Section was last modified on 11/16/20)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 9-1


Totally Integrated Power<br />

System Overview<br />

General<br />

9<br />

POWER<br />

MONITORING<br />

1. Power Meters<br />

Siemens power monitors combine the best of new technologies and<br />

proven practices. Monitor critical loads, power quality, and demand<br />

via the web directly from the meters.<br />

2. Power Monitoring Software<br />

WinPM.Net and Powermanager web-enabled software facilitates<br />

easy, enterprise-wide connection to power monitoring equipment,<br />

circuit breakers, and other devices from Siemens and third parties.<br />

Access information via the web with unlimited no-cost clients using<br />

built-in Web Client via your web browser.<br />

3. Communications Networks<br />

Utilize existing Ethernet or RS-485 communications networks to<br />

extract the information you need and get it where it needs to go.<br />

4. Components<br />

Current Transformers (CTs), Voltage/Potential Transformers (PTs),<br />

Power Supplies, Ethernet Switches, Protocol Converters. Siemens<br />

can provide everything required for your system.<br />

5. Intelligent I/O<br />

Our S7 I/O enables plug-n-play communications with Modbus<br />

devices and expands digital and analog input and output functionality<br />

of Siemens Systems.<br />

6. Billing and Load Allocation Software<br />

Powermanager is the simplified solution for cost allocation, billing &<br />

load/demand analysis using your web browser.<br />

7. Engineering Services<br />

PDS Application Engineers can help from design through<br />

commissioning of even the most demanding power quality<br />

and monitoring systems.<br />

8. Motor Control Centers<br />

Monitor mains and feeders for critical or power-intensive loads.<br />

Communicate with WL, VL and 3VA breakers, SIMOCODE, I/O and<br />

devices from other manufacturers. Use Siemens power meters to<br />

web-enable new as well as existing MCCs.<br />

9. Low- & Medium-Voltage Switchgear<br />

Web-enable switchgear by having Siemens power monitoring as well<br />

as breaker status and upload the information to a corporate Intranet<br />

or to the Internet. Use MeterMail TM directly from meters for alarm<br />

conditions or simple reporting.<br />

10. Facility Management Systems<br />

Tie into building automation systems to provide the required<br />

power and energy information. Many communications options<br />

are available ranging from legacy protocols to XML directly from<br />

the power monitors.<br />

11. Distributed Control Systems, Automation, and<br />

SCADA/Human Machine Interface<br />

Siemens power monitors and/or software can talk to all major<br />

vendors’ systems.<br />

9-2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Distribution Solutions<br />

Revised on 03/31/20<br />

Intelligent Metering and Control Devices<br />

PAC2200 PAC3120 MD Meter SEM3 PAC3200T PAC3220 PAC4200 9410 9810<br />

Power, Energy and Demand<br />

Voltage/current: per phase, average n n n n n n n n n<br />

Voltage/current: unbalance n n n n n n n n<br />

Power: real(kW), reactive(kVAR), apparent(kVA),<br />

power factor, frequency n n n n n n n n n<br />

Energy: bi-directional, import, export n n n n n n n n<br />

Energy kWh: total, net n n n n n n n n n<br />

Demand: block, sliding window n n n n n n n n n<br />

Demand: thermal predicted n n<br />

Power Quality Analysis<br />

Sag(Dip)/Swell disturbances monitoring n n<br />

Voltage disturbance direction detection n n<br />

High speed transient capture<br />

10MHz<br />

Harmonics (individual, even, odd, total) up to THD only THD only THD only 63rd 63rd 63rd<br />

Sampling rate, maximum samples/cycle 135k 135k 60 135k 135k 204 256 1024<br />

Flicker, harmonics to EN50160, IEC 6100-4-7 / 4-15 n n<br />

Configurable for IEEE 519-2014, SEMI/ITIC<br />

n<br />

Data and Waveform Logs<br />

Triggered by setpoint, schedule, or external signal n n<br />

Sequence-of-event logs or alarm logs, variable log depth n n n n<br />

Minimum/maximum logs n n n n n n<br />

Onboard Historical logging Memory c c 8GB (6 mos.) c c d 320MB 2GB<br />

Email data and event logs<br />

n<br />

Waveform recording n n<br />

Waveform in COMTRADE format with FTP n n<br />

GPS time synchronization NTP/SNTP NTP NTP/SNTP NTP/SNTP SNTP NTP/SNTP NTP/SNTP<br />

Time-stamps, resolution in seconds ±1 sec 1 min ±1 sec ±1 sec ±0.1 sec. ±0.1 msec. ±0.1 msec.<br />

Time synchronization - IEEE1588/IEC615888/PTP n n<br />

Communication Ports, Protocols and I/O<br />

( ) = Optional<br />

USB ports 1 2 (not activated)<br />

RS-485-only ports (1) 1 1 1 (1) (1) 1 2<br />

Ethernet ports (1) (1) 1 1 2 1 2 (UTP) 2 (UTP)<br />

PROFIBUS ports (1) (1)<br />

PROFINET ports (2) (2)<br />

Modbus RTU Slave on serial (n) n n n (n) (n) n n<br />

Modbus RTU Master on serial ports n n<br />

Modbus/TCP on Ethernet ports (n) n n n n n n n<br />

Modbus TCP Master over Ethernet n n<br />

BACnet MS/TP n n<br />

BACnet IP on Ethernet ports n n<br />

SNMP n n n<br />

DNP 3 n n<br />

IEC 61850 n n<br />

DHCP (n) n n n n n (IP v4/IP v6) n (IP v4/IP v6)<br />

RSTP n n<br />

Secure protocols (HTTPS, SFTP, SSH, Secure Modbus) HTTPS HTTPS<br />

Ethernet Gateway: 31 other meters accessible via RS-485 (n) n n<br />

Multiple masters over Ethernet 3 2 4 3 3 3 8 8<br />

On-board web server - Realtime, Trending (n) n (CSV output) n n n n n<br />

On-board web server - Waveform display n n<br />

Analog inputs (1) (1) (16) (16)<br />

Analog outputs (8) (8)<br />

Digital status/counter inputs (standard/optional add-ons) 1 2 2/(44) 1 2 / (8) 2 / (8) 3 / (24) 8 / (24)<br />

Digital relay outputs (control/pulse) 1 2 1 1 1 2 / (4) 2 / (4) 1 / (8) 4 FA/2RO (8RO) a<br />

Integrated display B/W B/W B/W Opt. Color B/W B/W Color Color<br />

Setpoints, Alarming and Control<br />

Setpoints, minimum response time n n n n n n ½ cycle ½ cycle<br />

Math, logic, trig, log, linearization formulas and/or, > < Grouping and/or, > < and/or, > < and/or, > < n n<br />

Multi-condition alarms n n n n n n<br />

Email on alarm n n<br />

Revenue metering<br />

ANSI C12.1 accuracy compliant 1.0 n n<br />

ANSI C12.20 0.5 0.2 0.2 0.5 0.5 0.2 0.2 b 0.2<br />

EN50160 Compliance Reporting n n (Ed4)<br />

IEC 61000-4-30 Class A/S n(Class S Meter) n(Class A Ed3)<br />

IEC 61577-12 accuracy compliant 1.0 0.5 0.5 0.5<br />

IEC 62053-22 replaces IEC 60687 0.2S compliant n n n n n n n (0.1S)<br />

IEC 62053-23, 24 compliant for Reactive Energy accuracy n n n n n (0.25)<br />

IEC 62586-1 (new Power Quality standard)<br />

n<br />

IEC 60687 accuracy class compliant n (1.0) n (0.5) n (0.2) n (0.5) n (0.5) n (0.2) n (0.2) n (0.2)<br />

ANSI class 10, IEC 1/10 (1A nominal, 10A max) n n<br />

ANSI class 20, IEC 5/20 (5A nominal, 20A max) n n<br />

Time-of-use n n n n n n n<br />

9 POWER<br />

MONITORING<br />

Some Features are optional, Refer to datasheets for allowable port configurations. Products meet or exceed the accuracy requirements of the standards listed; due to form factors, not all ANSI/IEC compliance tests may apply. Some products certified by third party laboratory.<br />

FA - Form A contact output, RO - Relay output.<br />

c Load profile kWh/day for 63 days. kWh/month for 24 months.<br />

b This meter is 0.2S compliant at 5A nominal CT, and 0.5S compliant at 1A nominal CT.<br />

d Load profile kWh/15min values for 40 days.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 9-3


Power Distribution Solutions<br />

Revised on 03/31/20<br />

PAC2200 Power Meter<br />

Reliable and Precise Monitoring of Electrical Power Systems<br />

The PAC2200 is a powerful compact din rail mounted<br />

power monitoring device that is suitable for use in<br />

industrial, government and commercial applications<br />

where basic metering and energy monitoring is required.<br />

The meter may be used as a standalone device monitoring<br />

over 50+ parameters or as part of an industrial control,<br />

building automation or global power monitoring system.<br />

Metering and monitoring applications range from simple<br />

analog volt and amp meter replacements to stand-alone<br />

sub billing or cost allocation installations with multiple<br />

tariffs.<br />

The PAC2200 provides open communications using Modbus<br />

RTU/TCP, and Mbus protocols for easy integration into<br />

any local or remote monitoring system. With a built-in web<br />

server viewing your data has never been easier. Simple<br />

configuration of the meter can be done from the front display<br />

or by using a PC with SENTRON powerconfig setup free<br />

software available for download from SIEMENS website.<br />

Precision<br />

n ANSI C12.1 Class 1<br />

n Energy Measurement<br />

• Voltage +/- 0.5%<br />

• Current +/- 0.5%<br />

• Power Factor +/- .5%<br />

• Sampling Rate 135K/per cycle<br />

n Revenue Accurate<br />

• Sub Billing<br />

• Cost Allocation<br />

• MID Certified variant for European<br />

customers<br />

n Cost Effective<br />

Energy Management<br />

n Serves three masters via the<br />

TCP connection<br />

n Energy Consumption<br />

n Automation Integration<br />

n Solution for LEED ® credit<br />

n Monitors Critical Equipment<br />

n Modbus TCP/RTU<br />

n Mbus<br />

Reliability<br />

n Economical Measurement<br />

• Commercial<br />

• Industrial<br />

• Residential<br />

n Degree of Protection<br />

• Front – IP40<br />

• Rear – IP20<br />

n 480V Connected Voltage<br />

n Simple Retrofit Installation<br />

n Integration with Existing Systems<br />

97 mm [3.8 in]<br />

71 mm<br />

[2.8 in]<br />

108 mm<br />

[4.2 in]<br />

9<br />

POWER<br />

MONITORING<br />

Condensed LCD Display to indicate:<br />

• Display title or designation of the<br />

displayed measurements<br />

• Phase<br />

• Measured value<br />

• Unit<br />

• Labeling of function keys<br />

Example of operating menu:<br />

The texts can be displayed in several languages, which can be<br />

selected directly on the device. The condensed graphic LCD<br />

display facilitates reading even from a distance. For optimum<br />

visability even in poor light conditions the PAC2200 comes with<br />

a gradually adjustable background illumination.<br />

Order information<br />

Product<br />

PAC2220 Modbus RTU, L-L: 400 V, L-N: 230 V, 5 Amp, self-powered, screw terminals<br />

PAC2220 Modbus TCP, L-L: 400 V, L-N: 230 V, 5 Amp, strd rail instr, self-powered, screw terminals<br />

PAC2220 Modbus RTU, MID Certified, L-L: 400 V, L-N: 230 V, 5 Amp, self-powered, screw terminals<br />

PAC2220 Modbus TCP, MID Certified ,L-L: 400 V, L-N: 230 V, 5 Amp, self-powered, screw terminals<br />

Catalog Number<br />

7KM22002EA301DA1<br />

7KM22002EA301EA1<br />

7KM22002EA301HA1<br />

7KM22002EA301JA1<br />

Languages included<br />

as standard in the<br />

meter are English,<br />

German, French,<br />

Spanish, Italian,<br />

Portuguese, Turkish,<br />

Russian and<br />

Chinese.<br />

9-4<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Distribution Solutions<br />

Revised on 03/31/20<br />

PAC3120 Power Meter<br />

Basic Monitoring of Electrical Power Systems<br />

The PAC3120 is a powerful compact power monitoring<br />

device that is suitable for use in industrial, government and<br />

commercial applications, where basic metering and energy<br />

monitoring is required. The meter may be used as a stand<br />

alone device monitoring over 100+ parameters or as part<br />

of an industrial control, building automation or global power<br />

monitoring system. Metering and monitoring applications<br />

range from simple analog volt and amp meter replacements<br />

to stand-alone sub-billing or cost allocation installations.<br />

Precision<br />

n ANSI C12.20 class 0.5<br />

n Energy Measurement<br />

• Voltage +/- 0.2%<br />

• Current +/- 0.2%<br />

• Power Factor +/- 0.5%<br />

• Sampling Rate 135k/per cycle<br />

n Revenue Accurate<br />

• Sub Billing<br />

• Cost Allocation<br />

n Cost Effective<br />

Energy Management<br />

n Energy Consumption<br />

n Demand Control<br />

n Automation Integration<br />

n Solution for LEED ® credit<br />

n Monitors Critical Equipment<br />

n Sub Metering<br />

The PAC3120 has many features not usually found in this<br />

price class of meters. A large graphical display supports<br />

multiple languages and easy to use menus that can be used<br />

to set up the meter. The meter also has built in Modbus RTU<br />

communications via a RS485 interface. The meter comes<br />

standard with two digital inputs and two digital outputs. One<br />

output is suitable for pulse output for export/import real and<br />

reactive energy. The other output is controllable from an<br />

outside source by way of a Modbus register.<br />

Reliability<br />

n Economical Measurement<br />

• Commercial<br />

• Industrial<br />

• Residential<br />

n Degree of Protection<br />

• Front – IP65<br />

• Rear – IP20<br />

n 480V Connected Voltage<br />

n Simple Retrofit Installation<br />

n Integration with Existing Systems<br />

96 mm [3.78 in.]<br />

Order information<br />

Product<br />

96 mm [3.78 in.]<br />

Full Graphic LCD Display to indicate:<br />

• Display title or designation<br />

of the displayed measurements<br />

• Phase<br />

• Measured value<br />

• Unit<br />

• Labeling of function keys<br />

PAC3120 Compression terminals AC/DC<br />

PAC3120 Compression terminals DC Only<br />

Adapter Plate for 4700/4720 meter cutout<br />

PAC32/4200 Meter DIN Rail adapter – Meter display will not be seen<br />

PAC32/4200 Meter DIN Rail 2-adapter – Meter display will not be seen<br />

Example of operating menu<br />

With an easy-to-read adjustable back lit LCD<br />

display, the PAC3120 can be commissioned in<br />

only two steps. After selecting the language<br />

and setting two parameters (voltage and<br />

current inputs), the meter is ready for use. <br />

Catalog Number<br />

7KM31200BA011DA0<br />

7KM31201BA011EA0<br />

93-47ADAPTER<br />

7KM9900-0YA00-0AA0<br />

7KM9900-0XA00-0AA0<br />

9 POWER<br />

MONITORING<br />

Languages included as standard in the meter are<br />

English, German, French, Spanish, Italian, Portuguese,<br />

Turkish, Russian and Chinese.<br />

Product Category: PDS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 9-5


Power Distribution Solutions<br />

Revised on 03/31/20<br />

PAC3200T Power Meter<br />

Reliable and Precise Monitoring of Electrical Power Systems<br />

The PAC3200T is a powerful compact din rail mounted power<br />

monitoring device that is suitable for use in industrial, government<br />

and commercial applications where basic metering and energy<br />

monitoring is required. The meter may be used as a standalone<br />

device monitoring over 100+ parameters or as part of an industrial<br />

control, building automation or global power monitoring system.<br />

Metering and monitoring applications range from simple analog<br />

volt and amp meter replacements to stand-alone sub billing or cost<br />

allocation installations with multiple tariffs.<br />

The PAC3200T provides open communications<br />

using Modbus TCP protocol for easy integration<br />

into any local or remote monitoring system. With<br />

a built-in web server viewing your data has never<br />

been easier. Simple configuration of the meter can<br />

be done by using a PC with SENTRON powerconfig<br />

setup free software available for download from<br />

SIEMENS website.<br />

Precision<br />

n ANSI C12.20 Class 0.5s<br />

n Energy Measurement<br />

• Voltage +/- 0.5%<br />

• Current +/- 0.5%<br />

• Power Factor +/- .5%<br />

• Sampling Rate 135K/per cycle<br />

• Total Harmonic Distortion (THD)<br />

n Revenue Accurate<br />

• Sub Billing<br />

• Cost Allocation<br />

n Cost Effective<br />

Energy Management<br />

n Serves three masters via the<br />

TCP connection<br />

n Energy Consumption<br />

n Automation Integration<br />

n Solution for LEED ® credit<br />

n Monitors Critical Equipment<br />

n Modbus TCP/RTU<br />

Reliability<br />

n Economical Measurement<br />

• Commercial<br />

• Industrial<br />

• Residential<br />

n Degree of Protection<br />

• Front – IP40<br />

• Rear – IP20<br />

n 480V Connected Voltage<br />

n Simple Retrofit Installation<br />

n Integration with Existing Systems<br />

97 mm [3.8 in]<br />

71 mm<br />

[2.8 in]<br />

108 mm<br />

[4.2 in]<br />

• DIN rail mount<br />

• Modbus TCP/Ethernet Port available on the<br />

top right slot<br />

• No Integrated display<br />

Current and Voltage Input<br />

wiring screw terminals<br />

Digital Input and Digital Output<br />

wiring screw terminals<br />

9<br />

POWER<br />

MONITORING<br />

Order information<br />

Product<br />

PAC3200T DIN Rail Mount Power Meter without DISPLAY, AC/DC, Modbus TCP, L-L: 400 V,<br />

L-N: 230 V, 5 A, wide-range pwr sup. unit AC/DC, screw terminals<br />

Catalog Number<br />

7KM32000CA011AA0<br />

Languages included<br />

as standard in the<br />

meter are English,<br />

German, French,<br />

Spanish, Italian,<br />

Portuguese, Turkish,<br />

Russian and<br />

Chinese.<br />

9-6<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Distribution Solutions<br />

Revised on 03/31/20<br />

PAC3220 Power Meter<br />

Reliable and Precise Monitoring of Electrical Power Systems<br />

The PAC3220 is a powerful compact power monitoring<br />

device that is suitable for use in industrial, government and<br />

commercial applications where basic metering and energy<br />

monitoring is required. The meter may be used as a stand<br />

alone device monitoring over 100+ parameters or as part of<br />

an industrial control, building automation or global power monitoring<br />

system. Metering and monitoring applications range from simple<br />

analog volt and amp meter replacements to stand-alone sub billing<br />

or cost allocation installations with multiple tariffs.<br />

The PAC3220 provides open communications using<br />

Modbus RTU/TCP, PROFIBUS-DP, and PROFINET<br />

protocols for easy integration into any local or remote<br />

monitoring system. With a built-in web server viewing<br />

your data has never been easier. Simple configuration of<br />

the meter can be done from the front display or by using<br />

a PC with SENTRON powerconfig setup free software<br />

available for download from SIEMENS website.<br />

Precision<br />

n ANSI C12.20 Class 0.5s<br />

n Energy Measurement<br />

• Voltage +/- 0.2%<br />

• Current +/- .2%<br />

• Power Factor +/- .5%<br />

• Sampling Rate 135K/per cycle<br />

• Total Harmonic Distortion (THD)<br />

n Revenue Accurate<br />

• Sub Billing<br />

• Cost Allocation<br />

n Cost Effective<br />

Energy Management<br />

n Serves three masters via the<br />

TCP connection<br />

n Energy Consumption<br />

n Automation Integration<br />

n Solution for LEED ® credit<br />

n Monitors Critical Equipment<br />

n Modbus TCP/RTU<br />

n Industrial Systems<br />

• PROFIBUS<br />

• PROFINET<br />

Reliability<br />

n Economical Measurement<br />

• Commercial<br />

• Industrial<br />

• Residential<br />

n Degree of Protection<br />

• Front – IP65<br />

• Rear – IP20<br />

n 600V Connected Voltage<br />

n Simple Retrofit Installation<br />

n Integration with Existing Systems<br />

96 mm [3.78 in.]<br />

96 mm [3.78 in.]<br />

Full Graphic LCD Display to indicate:<br />

• Display title or designation of the<br />

displayed measurements<br />

• Phase<br />

• Measured value<br />

• Unit<br />

• Labeling of function keys<br />

Order information<br />

Example of operating menu:<br />

The texts can be displayed in several languages, which can<br />

be selected directly on the device. The large graphic LCD<br />

display facilitates reading even from a distance. For optimum<br />

visability even in poor light conditions the PAC3220<br />

comes with a gradually adjustable background illumination.<br />

Product<br />

PAC3220 compression terminals (not suitable for use with ring tongue terminals), AC/DC<br />

PAC3220 compression terminals (not suitable for use with ring tongue terminals), DC only<br />

Expansion Module - PAC PROFIBUS DP<br />

Expansion Module - PAC PROFINET<br />

Expansion Module - PAC MODBUS RTU<br />

Expansion Module - I(N), I(Diff), Analog for PAC 3220 or 4200<br />

PAC3220/4200 Meter DIN Rail adapter – Meter display will not be seen<br />

PAC3220/4200 Meter DIN Rail 2-Tier adapter – Meter display will not be seen<br />

Power Supply. Input: 120-230V AC / 110-300V DC Output: 24 V DC 4 Amps. DIN Rail mounted.<br />

Adapter Plate for 4700/4720 meter cutout<br />

Catalog Number<br />

7KM32200BA011DA0<br />

7KM32201BA011EA0<br />

7KM93000AB010AA0<br />

7KM93000AE020AA0<br />

7KM99000XA000AA0<br />

7KM92000AD000AA0<br />

7KM99000YA000AA0<br />

7KM99000XA000AA0<br />

US2:PWRSP4A<br />

93-47ADAPTER<br />

Example of Optional<br />

Expansion Module install<br />

Languages included<br />

as standard in the<br />

meter are English,<br />

German, French,<br />

Spanish, Italian,<br />

Portuguese, Turkish,<br />

Russian and<br />

Chinese.<br />

9 POWER<br />

MONITORING<br />

Product Category: PDS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 9-7


•<br />

Power Distribution Solutions<br />

Revised on 03/31/20<br />

PAC4200 Power Meter<br />

Reliable and Precise Monitoring of Electrical Power Systems<br />

The PAC4200 is a feature packed power monitoring device<br />

that is suitable for use in industrial, government and<br />

commercial applications where basic to advanced metering,<br />

logging, and I/O is required. The meter may be used as a<br />

stand alone device monitoring over 200 parameters or as<br />

part of an industrial control, building automation or global<br />

enterprise wide monitoring system.<br />

Advanced power quality monitoring and logging applications<br />

range from single low-voltage breaker / building metering<br />

to sub-station main feeder monitoring, sub-billing or cost<br />

allocation installations with multiple tariffs. Whether your goal<br />

is to reduce operation cost, reduce your carbon footprint or to<br />

maintain your power assets, the PAC4200 meter should be an<br />

important part of your power monitoring system.<br />

The PAC4200 provides open communication using the<br />

standard built-in Ethernet Modbus TCP and has the capability<br />

of communicating through Optional Modbus RTU, PROFIBUS-<br />

DP, and PROFINET protocol modules simultaneously. This<br />

allows for easy integration into any local or remote monitoring<br />

system. With a built-in web server viewing your data has<br />

never been easier. The gateway functionality of this device<br />

reduces installation cost by replacing other gateway devices<br />

and simplifying wiring.<br />

Precision<br />

n ANSI C12.20 Class .2s<br />

n Energy Measurement<br />

• Voltage +/- .2%<br />

• Current +/- .2%<br />

• Power Factor +/- .5%<br />

• Sampling Rate 204/per cycle<br />

• Individual Harmonics up to 63rd<br />

n Power Quality<br />

n Revenue Accurate<br />

• Sub Billing<br />

• Cost Allocation<br />

n Cost Effective<br />

Energy Management<br />

n Serves three masters via the<br />

TCP connection<br />

n Energy Consumption<br />

n Min/Max and Event Logs<br />

• Storage Capacity 40 days at 15 min<br />

intervals<br />

• Event Logging 4000 events<br />

n Demand Control<br />

n Automation Integration<br />

n Modbus Gateway<br />

n Modbus TCP/RTU<br />

n Industrial Systems<br />

• PROFIBUS • PROFINET<br />

Reliability<br />

n Monitors Critical Equipment<br />

n Economical Measurement<br />

• Commercial<br />

• Industrial<br />

n Degree of Protection<br />

• Front – IP65<br />

• Rear – IP20<br />

n 600V Connected Voltage<br />

n Customizable Displays<br />

n Simple Retrofit Installation<br />

n Integration with Existing Systems<br />

n Solution for LEED ® credit<br />

SENTRON PAC, PROFIBUS<br />

DP, MODBUS RTU and PROFINET<br />

expansion modules for<br />

remote data transmission.<br />

Two Digital Input and two<br />

Digital Outputs as standard<br />

MODBUS TCP<br />

integrated into the<br />

meter as standard<br />

•<br />

Terminal blocks for voltage<br />

and current measuring,<br />

control power and digital<br />

input and output<br />

•<br />

96<br />

mm<br />

3.78<br />

in.<br />

Digital input and output<br />

module provides 4 additional<br />

digital inputs and 2 digital outputs<br />

96 mm<br />

3.78 in.<br />

77 mm<br />

3.03 in. <br />

9<br />

POWER<br />

MONITORING<br />

Order information<br />

Product<br />

Catalog Number<br />

PAC4200 compression terminals (not suitable for use with ring tongue terminals), AC/DC<br />

7KM42120BA003AA0<br />

PAC4200 compression terminals (not suitable for use with ring tongue terminals), DC only<br />

7KM42111BA003AA0<br />

Expansion Module - PAC PROFIBUS DP<br />

7KM93000AB010AA0<br />

Expansion Module - PAC PROFINET<br />

7KM93000AE020AA0<br />

Expansion Module - PAC MODBUS RTU<br />

7KM99000XA000AA0<br />

Expansion Module - PAC additional I/O<br />

7KM92000AB000AA0<br />

Expansion Module - I(N), I(Diff), Analog for PAC 3220 or 4200<br />

7KM92000AD000AA0<br />

PAC3220/4200 Meter DIN Rail adapter – Meter display will not be seen 7KM99000YA000AA0<br />

PAC3220/4200 Meter DIN Rail 2-Tier adapter – Meter display will not be seen<br />

7KM99000XA000AA0<br />

Power Supply. Input: 120-230V AC / 110-300V DC Output: 24 V DC 4 Amps. DIN Rail mounted.<br />

US2:PWRSP4A<br />

Adapter Plate for 4700/4720 meter cutout 93-47ADAPTER<br />

99mm, 3.90 in., with<br />

expansion module<br />

9-8<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: PDS


Power Distribution Solutions<br />

Revised on 04/30/19<br />

9410 Web-Enabled Power Quality & Analysis Meter<br />

Reliable and Precise Monitoring of Electrical Power Systems<br />

The 9410 series meters are ideally suited to local and remote monitoring of lowor<br />

high-voltage electrical installations in industrial facilities, commercial buildings,<br />

utility networks or critical power environments. Facility and operations personnel<br />

will benefit in energy-related costs while avoiding power quality conditions that<br />

can reduce equipment life and productivity.<br />

The 9410 series meter is easy to install and use, offering integrated or remote<br />

high-visibility displays. A range of expansion modules help match features to<br />

the application and support field-upgrading of meters as required. Serial and<br />

Ethernet communication enable the meter to be used within a WinPM.Net power<br />

management system or with third-party management systems.<br />

Precision<br />

n ANSI C12.20 Class 0.2s<br />

• Energy Measurement<br />

• Voltage +/- .1%<br />

• Current +/- .1%<br />

• Power Factor +/- .5%<br />

• Sampling Rate 256/<br />

per cycle<br />

• Individual Harmonics<br />

up to 63rd<br />

• Sags / Swells<br />

Detection<br />

• Programmable Math /<br />

Logic Function<br />

n Revenue Accurate<br />

• Sub Billing<br />

• Cost Allocation<br />

Order information<br />

Energy Management<br />

n Energy Consumption<br />

n 9410 Waveform Capture<br />

n Onboard Waveform<br />

Display Webpages<br />

n Customizable<br />

Webpages<br />

n Min/Max and<br />

Event Logs<br />

n Demand Control<br />

n Automation Integration<br />

n Solution for LEED ®<br />

credit<br />

n Monitors Critical<br />

Equipment<br />

n Modbus Gateway<br />

n Modbus TCP/RTU<br />

n Modbus Master<br />

n Industrial Systems<br />

n IEC 61850 Protocol<br />

Reliability<br />

n Economical<br />

Measurement<br />

• Commercial<br />

• Industrial<br />

n Degree of Protection<br />

• Front – IP54,<br />

UL type 12<br />

• Rear – IP30<br />

n 600V Connected<br />

Voltage<br />

n Customizable Displays<br />

n Email Alarms through<br />

Ethernet<br />

n Field Addable Modules<br />

n Simple Retrofit<br />

Installation<br />

n Integration with<br />

Existing Systems<br />

Product<br />

Catalog Number<br />

9410 AC Powered Panel meter with integrated color display, 1 DO, 3 DI,<br />

dual port Ethernet<br />

US2:9410DC<br />

9410 AC Powered DIN transducer meter packaged with remote display<br />

(includes 3m cable )<br />

US2:9410RC<br />

9410 AC Powered Meter without display (DIN rail mount transducer version)<br />

with 1 DO, 3 DI, dual port Ethernet<br />

US2:9410TC<br />

9410 DC Powered Panel meter with integrated color display, 1 DO, 3 DI,<br />

dual port Ethernet, 20Vdc-60Vdc PS<br />

US2:9410D24VDC<br />

9410 DC Powered DIN transducer meter packaged with remote display<br />

(includes 3m cable ), 20Vdc-60Vdc PS<br />

US2:9410R24VDC<br />

9410 DC Powered Meter without display (DIN rail mount transducer version)<br />

with 1 DO, 3 DI, dual port Ethernet, 20Vdc-60Vdc PS<br />

US2:9410T24VDC<br />

9410 Panel meter with integrated color display, 1 DO, 3 DI, dual port Ethernet.<br />

Measurement Canada - Ready to be Hardware/Firmware sealable. SIEMENS US2:9410DCAN<br />

Canada to work with local sealing house for actual hardware sealing<br />

Accessories<br />

Catalog Number<br />

9410 Remote color LCD display, 96 mm x 96 mm, with 3 m cable US2:948DISP96<br />

9410 I/O Module with 2 relay outputs, and 6 digital inputs (wetted) US2:948M2DO6DI<br />

9410 I/O Module, 2 analog outputs (4 - 20 mA, 0- 10 VDC), and 4 analog<br />

inputs (4 - 20 mA, 0 - 30 VDC)<br />

US2:948M2AO4AI<br />

9410 Voltage and Current Sealing Kit (included with base meter) US2:9410SK<br />

9410 Remote display cable, 10 meters US2:948DCAB10<br />

9410 Remote Display Mounting Adapter kit for 4" round hole - requires 9410RC US2:94PMAK<br />

9410 Replacement hardware kit for 9410 meter US2:94PMHWK<br />

9410 Replacement hardware kit for remote display US2:94PMRDHWK<br />

9410 24Vdc Meter replacement hardware kit for remote display US2:94PMHWKDC<br />

A.<br />

B.<br />

C.<br />

D.<br />

3.562 in.<br />

90.5 mm<br />

Dimensions for I O<br />

modules typical.<br />

Up to four modules<br />

allowed to<br />

be connected.<br />

3.562 in.<br />

90.5 mm<br />

3.562 in.<br />

90.5 mm<br />

3.562 in.<br />

90.5 mm<br />

3.62 in.<br />

92 mm + 0.8-0.0<br />

3.562 in.<br />

90.5 mm<br />

3.78 in.<br />

96 mm<br />

0.866 in.<br />

22 mm 77.5 in.<br />

3.051mm<br />

6.515 Max in.<br />

165.48 Max mm<br />

3.562 in.<br />

90.5 mm<br />

0.866 in.<br />

66 mm<br />

3.574 in.<br />

90.8 mm<br />

3.562 in.<br />

90.5 mm<br />

3.62 in.<br />

92 mm + 0.8-0.0<br />

3.78 in.<br />

96 mm<br />

3.574 in.<br />

90.8 mm<br />

3.562 in.<br />

90.5 mm<br />

Dimensions for I O<br />

modules typical.<br />

Up to four modules<br />

allowed to<br />

be connected.<br />

3.78 in.<br />

96 mm<br />

3.78 in.<br />

96 mm<br />

Dimensions:<br />

A. Meter with integrated display panel mount<br />

into a square cutout<br />

B. Meter with integrated display with up to<br />

(4) I/O module<br />

C. Din Rail mounted meter with up to<br />

(4) I/O modules<br />

D. Din Rail Mounted meter with remote display<br />

9 POWER<br />

MONITORING<br />

Product Category: PDS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 9-9


Power Distribution Solutions<br />

Revised on 04/30/19<br />

9810 High Accuracy Advanced Power Quality and Analysis Meter<br />

Power Quality Meter with Web Server Technology<br />

The Siemens 9810 series high accuracy and advanced power quality meter combines<br />

accurate; 3-phase energy and power measurement with data logging, power quality<br />

analysis, e-mail, alarming, Modbus mastering, Transient detection, Disturbance<br />

Direction Detection (DDD), Pre-Event/Post-Event Waveform capture and extensive<br />

I/O capabilities in a highly flexible and modular format. Analysis results are captured<br />

in the event log, along with a time-stamp and confidence level indicating level of<br />

certainty. The 9810 base meter includes 8 digital inputs capable of providing ±1<br />

millisecond time stamping and 4 digital outputs. The 9810 meters support numerous<br />

protocols including Modbus, ION, DNP3, IEC 61850, HTTP, HTTPS, DLMS, FTP,<br />

SNMP, SMTP, DPWS, RSTP, PTP, NTP/SNTP, GPS, Syslog, and DHCP protocols.<br />

Fast sampling rates and extensive memory make this the perfect choice for critical<br />

power systems making analysis of issues possible for correction and prevention.<br />

As a data accumulator, the 9810 meter can also save money and time by simplifying<br />

wiring and networking. Information from the meter and downstream devices can<br />

be displayed on the large capacitive 7” touch display or smaller 3.5” display, on<br />

customizable web pages in reports and screens.<br />

Applications for the 9810 meter range from<br />

A<br />

critical power applications A such as<br />

data centers to industrial, commercial and government power and power quality<br />

monitoring systems. The 9810 meter is offered in a number of forms from single<br />

meter enclosures integrated into Siemens switchgear, switchboard and panelboards.<br />

Place this high end power quality meter throughout the power distribution system<br />

where critical information is desired. Know what is happening in your facility and get<br />

maximum efficiency.<br />

Precision<br />

n ANSI C12.20 Class .1s<br />

n Energy Measurement<br />

• Voltage +/- .1%<br />

• Current +/- .1%<br />

• Power A Factor +/- .5%<br />

• 9810 Sampling Rate<br />

1024 samples per cycle<br />

• 9810 Individual Harmonics<br />

up to 63rd<br />

• Sags / Swells Detection<br />

• Programmable Math /<br />

Logic Function<br />

n Revenue Accurate<br />

• Sub Billing<br />

• Cost Allocation<br />

B<br />

3.562 in.<br />

90.5 mm<br />

Reliability<br />

n Economical Measurement<br />

• Commercial<br />

• Industrial<br />

n 600V Connected Voltage<br />

n Email BAlarms<br />

Cn Customizable Displays 5.33 in.<br />

6.30 in. C<br />

135.3 mm<br />

n 3.562 Password in. Protected 160 mm<br />

3.562 in.<br />

90.5 mm<br />

90.5 mm<br />

n Hardware Lockable<br />

n Supports Copper Ethernet<br />

n Integration with Existing Systems<br />

3.562 in.<br />

90.5 mm<br />

6.30 in.<br />

160 mm<br />

B<br />

B<br />

Energy Management<br />

n Energy Consumption<br />

n Waveform Capture<br />

n Transient Capture 17 μs @ 60 Hz<br />

n Disturbance Direction Detection<br />

(DDD)<br />

n Customizable Webpages<br />

n Extensive data logging, trending<br />

and forecasting<br />

Non-volatile on-board logging of min/<br />

max values, energy and demand,<br />

maintenance data, alarms, and any<br />

measured parameters. Trending and<br />

short-term forecasting of energy,<br />

demand, D<br />

6.30 in<br />

5.33 and in. measured 160 parameters.<br />

mm D<br />

135.3 mm<br />

n Demand Control<br />

n Automation Integration<br />

6.30 in.<br />

160 mm<br />

n Monitors Critical Equipment<br />

n Modbus Master / Gateway<br />

6.30 in.<br />

n Supports Multiple 160 mm Protocols<br />

n Supports Multiple Master via<br />

Ethernet<br />

6.30 in<br />

160 mm<br />

6.30<br />

160<br />

.562 in.<br />

0.5 mm<br />

9<br />

POWER<br />

MONITORING<br />

Din rail mounted meter<br />

with 4 I/O modules<br />

C<br />

3.562 in.<br />

6.30 in. 90.5 mm<br />

160 mm<br />

3.562 in.<br />

90.5 mm<br />

6.30 in.<br />

5.33 in. 160 mm<br />

135.3 mm<br />

6.30 in.<br />

160 mm<br />

5.33 in.<br />

135.3 mm<br />

D<br />

E<br />

6.30 in.<br />

160 mm<br />

Dimensions for I/O modules typical.<br />

0.866 in. Up to four modules allowed 0.866 in. to<br />

66 mm be connected. 66 mm be connected.<br />

Back-to-back adapter used to Large 7 in. touchscreen<br />

panel mount display and meter capacitive display<br />

D<br />

6.30 in<br />

160 mm<br />

6.30 in 7.76 in.<br />

160 mm 197 mm<br />

E<br />

6.30 in<br />

160 mm<br />

6.89 in.<br />

175 mm<br />

Dimensions for I/O modules typical.<br />

Up to four modules allowed to<br />

7.76 in.<br />

197 mm<br />

6.30 in<br />

160 mm<br />

F<br />

6.89 in.<br />

175 mm<br />

3.5 in. pushbutton<br />

display<br />

3.78 in.<br />

96 mm<br />

F<br />

3.78 in.<br />

96 mm<br />

3.7<br />

96<br />

0.866 in.<br />

66 mm<br />

Dimensions for I/O modules typical.<br />

0.866 in. Up to four modules allowed to<br />

Dimensions for 66 I/O mm modules typical. be connected. Dimensions:<br />

Up to four modules allowed to<br />

Dimensions:<br />

be connected.<br />

A. Back-to-back adapter cutout A. Back-to-back dimensions adapter B. cutout 96mm dimensions mounting adapter cutout B. 96mm mounting adapter cutout<br />

9-10 E<br />

7.76 in.<br />

197 mm<br />

C. Din rail mounted meter with<br />

Siemens Industry, 7.76 in. Inc. SPEEDFAX Product Catalog F C. Din 4 I/O rail modules mounted meter D. Back-to-back with 4 I/O modules adapter used D. to Back-to-back panel mount adapter display used and meter to panel m<br />

3.78 in.<br />

Product Category: PDS<br />

197 mm<br />

F<br />

96 mm<br />

E. Large 7in touchscreen 3.78 in. capacitive E. Large display 7in touchscreen F. 3.5in capacitive pushbutton display display F. 3.5in pushbutton display<br />

96 mm


Power Distribution Solutions<br />

Revised on 02/28/19<br />

9810 High Accuracy Advanced Power Quality and Analysis Meter<br />

Order information<br />

Product<br />

Catalog Number<br />

9810 with 7" display (either din rail or panel mount) US2:9810RC<br />

Ø 3.7 - 4.0<br />

(.146 - .157)<br />

9810 without display US2:9810TC<br />

Accessories<br />

Catalog Number<br />

Ø 4.0 - 3.5<br />

(0.14 - 0.16) Ø 30.0 - 31.0<br />

(1.18 - 1.22)<br />

Large 7" display<br />

US2:9810R7DISP<br />

82.4<br />

(3.24)<br />

Small 3.5" display + 3M cable<br />

US2:948DISP96<br />

Remote display cable 10 M<br />

US2:948DCAB10<br />

Remote display hardware kit<br />

Expansion Modules<br />

I/O Module-Digital (6IN/2OUT)<br />

US2:9810PMRDHWK<br />

Catalog Number<br />

US2:948M2DO6DI<br />

30.0<br />

(1.18)<br />

82.4<br />

(3.24)<br />

I/AI Module-Analog (4IN/2OUT)<br />

US2:948M2AO4AI<br />

Miscellaneous<br />

Catalog Number<br />

9810 Hardware Kit US2:9810PMHWK<br />

mm<br />

(in)<br />

197<br />

(7.76)<br />

9810 Back to Back adapter US2:9810BBADAPTER<br />

9810 Current Input Green Connectors Hardware Kit. US2:9810CTHWK<br />

9610/9510/ADR to 9810 mounting adapter<br />

US2:9810MADAPTER<br />

92.8 - 92.0<br />

(3.65 - 3.62)<br />

Electrical Characteristics<br />

Measurement<br />

accuracy<br />

Data update rate<br />

Input-voltage<br />

characteristics<br />

Input-current<br />

characteristics<br />

Current and voltage Class 0.1 as per IEC 61557-12<br />

Active power Class 0.1 as per IEC 61557-12<br />

Power factor Class 0.5 as per IEC 61557-12<br />

Frequency Class 0.02 as per IEC 61557-12<br />

Active energy<br />

Class 0.1S IEC 62053-22 (In=5A)<br />

Class 0.1 IEC 61557-12,<br />

ANSI C12.20 Class 0.1<br />

Reactive energy Class 0.5S IEC 62053-24<br />

1/2 cycle or 1 second<br />

Specified accuracy voltage<br />

57 VLN/100 VLL TO 400 VLN/690 VLL<br />

Impedance<br />

5MΩ per phase<br />

Specified accuracy frequency 42 to 69Hz (50/60Hz nominal)<br />

Limit range of operation -frequency 20 to 450Hz<br />

Rated nominal current<br />

1A (0.1S), 5A (0.1S), 20A (0.1ANSI)<br />

Specified accuracy current range Starting Current: 1mA (No Accuracy)<br />

Accurate Range: 10mA-20A<br />

Permissible overload<br />

500A rms for 1s<br />

Impedance<br />

0.0003Ω per phase<br />

Burden<br />

0.01 VA max at 5A<br />

Power supply AC 90-480V AC ±10% (50/60Hz ± 10%), 90-120V AC ±10% (400Hz)<br />

DC 110-480V DC ±15%<br />

Ride-through time<br />

100 ms (6 cycles at 60Hz) typical, 120V AC<br />

400 ms (24 cycles at 60Hz) typical, 240V AC<br />

1200 ms (72 cycles at 60Hz) typical, 480V AC<br />

Burden<br />

Meter Only: 16.5W/38 VA max at 480V AC (50/60 Hz)<br />

Fully optioned meter: 40W/80 VA max at 480V AC (50/60 Hz)<br />

Input/outputs Meter Base Only Meter Base Only 8 form A digital inputs (30V AC/60V DC)<br />

4 form A (KY) solid state digital output (30V AC/60V, 75mA)<br />

2 form C relay outputs (8 A at 250 V AC/ 5 A at 24 V DC)<br />

Optional<br />

Digital - 6 form A digital inputs (30V AC/60V DC) 8 A at 250V AC or 5A at 24V DC)<br />

Analog - 4 analog inputs (4-20mA, 0-30V DC) +2 analog outputs (4-20mA 0-10V DC)<br />

Mechanical Characteristics<br />

175<br />

(6.89)<br />

48.6 - 48.2<br />

(1.91 - 1.90)<br />

92.8 - 92.0<br />

(3.65 - 3.62)<br />

67.2 - 66.8<br />

(2.65 - 2.63)<br />

Ø 23.0 - 22.0<br />

(0.91 - 0.87)<br />

9 POWER<br />

MONITORING<br />

Weight<br />

IP degree of<br />

protection<br />

DIN rail mounted Model 1.5 kg<br />

IO modules 0.140 kg<br />

7” Touchscreen display: 0.861 kg<br />

3.5” Display: 0.300 kg<br />

IP 65, UL type 12: Panel mount and<br />

touchscreen display, front.<br />

IP 30: Panel mount rear, DIN rail mount,<br />

I/O modules.<br />

Dimensions<br />

Panel mount model: Color remote display<br />

(2 options): 197 x 175 x 27.5 mm touchscreen<br />

96 x 96 x 27 mm pushbutton<br />

DIN model<br />

IO modules<br />

Touchscreen Display(s)<br />

160 x 160 x 135.3 mm<br />

160 x 160 x 135.3 mm<br />

90.5 x 90.5 x 22 mm<br />

192 mm and 96 mm<br />

Product Category: PDS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 9-11


Power Distribution Solutions<br />

Revised on 10/15/20<br />

Enclosed Meters<br />

Convenience and Reliability with<br />

Siemens Meter Enclosures<br />

The Siemens meter enclosure offering is available to order with<br />

the SENTRON PAC series meters, the ACCESS series meters,<br />

and a combination of both power meter product offerings. The<br />

enclosed meter offering provides the required energy and basic<br />

metering information needed for a typical sub-billing / cost<br />

allocation application, as well as providing a simple retrofit solution<br />

for any project.<br />

With Safety being paramount, Siemens has designed the meter<br />

enclosure product offering with many safety and convenience<br />

features in mind. These include a single circuit breaker for both<br />

the control voltage & voltage taps to protect internal wiring<br />

and the power meters from damage and allowing a “single<br />

source” disconnect from outside power, separate CT shorting<br />

blocks for each meter, a grounding lug, and the Modbus serial<br />

communications will be terminated to one location for ease of<br />

network installation.<br />

The Siemens meter enclosure solutions are delivered with all<br />

the required components pre-installed prior to shipment. All<br />

components will be mounted to a back plate in the enclosure and<br />

for applications above 240 volts, a CPT will be provided for control.<br />

For low cost and simple tenant monitoring, sub-billing or<br />

industrial cost allocation, turn to Siemens metering units.<br />

Installed in rugged NEMA 1 or NEMA 12 enclosures, these<br />

metering units are ideal for:<br />

n Property Management Firms<br />

n Government Applications<br />

n Universities<br />

n Corporate Campus Facilities<br />

n Malls<br />

n Food Courts<br />

n Building Retrofits<br />

Features:<br />

n Rugged design and small footprint for easy installation<br />

n Bright, easy-to-read LCD display<br />

n Multiple configurations<br />

n Packaged by voltage and current ratings to<br />

accommodate any installation<br />

n Utilizes 5A secondary current input for improved<br />

accuracy and increased compatibility<br />

Benefits:<br />

n Replace multiple utility meters with one enclosure,<br />

saves wall space<br />

n Consolidate utility bills for sub-billing and energy<br />

management, bill tenants on actual usage<br />

n Improve energy efficiency<br />

n Aggregate energy purchases for reduced rates<br />

n Improve productivity when coupled with Siemens<br />

software solutions or third party billing software<br />

Catalog Logic:<br />

E N C L X X X X X X X X X X<br />

9<br />

POWER<br />

MONITORING<br />

Meter<br />

31 PAC3100 Series Meter <br />

32 PAC3200 Series Meter <br />

42 PAC4200 Series Meter <br />

Voltage<br />

240 240V<br />

480 480V<br />

Type<br />

01 NEMA 1 Enclosure<br />

12 NEMA 12 Enclosure<br />

Module<br />

TC Standard<br />

RT Modbus RTU <br />

PD PROFIBUS <br />

PN PROFINET <br />

Options<br />

X Standard<br />

PAC3100 standard is Modbus RTU.<br />

PAC3200 and PAC4200 Standard is Modbus TCP.<br />

Modules not available on PAC3100.<br />

Meter Enclosure<br />

Catalog Number<br />

Description<br />

US2:ENCL3124001TCX PAC3100,240V, NEMA1<br />

US2:ENCL3148012TCX PAC3100,480V, NEMA12<br />

US2:ENCL3224001TCX PAC3200,240V, NEMA 1<br />

US2:ENCL3248012TCX PAC3200,480V, NEMA12<br />

9-12<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category PDS


Power Distribution Solutions<br />

Revised on 02/28/19<br />

Branch Circuit Monitoring/ SEM3 Embedded Metering<br />

Space Savings, Convenience, and Reliability with Siemens Branch Circuit Monitoring<br />

In a world where tenant square<br />

footage is a premium in commercial<br />

building designs, the area for electrical<br />

metering is being drastically reduced,<br />

and critical power is being relied upon<br />

in data centers applications, Siemens<br />

Branch Circuit Monitoring provides<br />

the solution.<br />

The Siemens Branch Circuit<br />

Monitoring Solution utilizes the<br />

metering and monitoring technology<br />

integrated into the space saving<br />

panelboards from Siemens. When<br />

compared to the typical external<br />

wall mounted metering installations,<br />

considerable savings in space,<br />

installation costs, and data collection<br />

are realized with the Siemens Branch<br />

Circuit Monitoring Solution.<br />

In addition, contractor labor costs for<br />

installation of sub-metering systems<br />

continues to increase. Still, building<br />

owners and property management<br />

companies must face the challenges of<br />

how to cost effectively provide tenant<br />

sub-metering in the constrained spaces.<br />

To meet the sub-metering challenges<br />

of designers, contractors and property<br />

management companies, Siemens<br />

offers a proven cost-effective solution<br />

for Branch Circuit Monitoring/Embedded<br />

Metering .This solution combines a fully<br />

integrated metering system factory<br />

installed into the Siemens Panelboards,<br />

Switchboards, Bus Plug and remote<br />

external wall mount enclosures, which<br />

along with the required local or remote<br />

sub-billing software, provides a “Total”<br />

sub-metering system.<br />

Siemens Branch Circuit Monitoring /<br />

Embedded Metering Solution<br />

n Saves you money – A tenant billing system improves cash<br />

flow, allows immediate pass-on of electric rate increases<br />

and helps building owners control costs. Tenants are<br />

confident they are paying their fair share for energy use and<br />

are saving money through energy conservation.<br />

n Fast, low-cost installation – The embedded Siemens<br />

solution provides a faster and lower cost installation<br />

compared to other external systems.<br />

n Lower space requirements – The embedded panelboard<br />

construction design requires no additional wall space to<br />

provide tenant metering. Conventional metering requires<br />

an external metering enclosure and possibly a current<br />

transformer transition cabinet.<br />

n Reliable and accurate – Many Siemens systems are already<br />

in operation in large commercial and residential buildings<br />

around the country. Their accuracy exceeds utility industry<br />

and government standards for revenue grade meters.<br />

n LEED certification – Provides the energy monitoring and<br />

logging required to achieve additional LEED points.<br />

n Automated billing – With automated billing services the<br />

responsibility to acquire the data, store the data and bill<br />

the tenants is removed from the property management<br />

company, thus saving manpower and time.<br />

n Responsive service – With remote monitoring, continuous<br />

24/7 monitoring can be done by the property management<br />

company or tenants. The service can also relay consumption<br />

changes to the owners for immediate investigation.<br />

Designer and contractor benefits include:<br />

n Much smaller footprint versus the traditional socket meter<br />

combo units<br />

n Factory pre-wired – less installation time<br />

n Drastically less installation wiring<br />

n No CT installation required in the field<br />

n All equipment fits into the standard Siemens panel design<br />

n Additional utilities like water, air and gas can be easily<br />

integrated into the system for a comprehensive monitoring<br />

system<br />

n Hardwire and wireless communication options<br />

n All components factory calibrated to meet revenue metering<br />

requirements<br />

n Additional meters can be added in the field<br />

n UL, IEC, BTL, ANSI and CSA approved<br />

n NY & CA State Approved Meter.<br />

n Embedded web-server for on-site configuration and real<br />

time data view.<br />

n Monitor 1 to 45 branch circuits.<br />

Branch Circuit Monitoring applications include:<br />

n Mixed Tenant & Retail<br />

n Industrial Manufacturing<br />

n Higher Ed<br />

n Strip Malls<br />

n Critical Power<br />

n Goverment<br />

n LEEDS buildings<br />

n Airports<br />

9 POWER<br />

MONITORING<br />

Please Contact Your Siemens Sales Engineer for additional information<br />

regarding Branch Circuit Monitoring / Embedded Metering<br />

Product Category: PDS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 9-13


Power Distribution Solutions<br />

Revised on 11/30/20<br />

Branch Circuit Monitoring/ SEM3 Embedded Micro Sub Metering<br />

9<br />

POWER<br />

MONITORING<br />

Powerful embedded metering at the source of consumption!<br />

The new Siemens Embedded Micro Metering Module (SEM3) is a modular metering<br />

solution for energy monitoring, data analysis, and sub billing applications. The flexible<br />

design allows for low, medium, and high density metering requirements to be met<br />

efficiently and economically using only a few standardized components integrated into<br />

Siemens Panelboard and Switchboard products. SEM3 is pre-engineered to integrate<br />

into new Siemens Panelboards and Switchboards but has also been designed to be<br />

implemented in OEM and retrofit applications as well.<br />

The SEM3 provides an innovative and cost effective metering solution that can be<br />

incorporated into existing applications such as power monitoring, building automation,<br />

and sub-billing systems. SEM3 also has the flexibility to be installed as a standalone<br />

solution with real time data available from the controller’s standard built-in web pages.<br />

This metering product has two levels of accuracy to meet the market’s differing<br />

requirements and price points. This versatile system allows you to meter just the<br />

loads you need without the excess hardware and space requirements of traditional<br />

or competing solutions.<br />

Order Information<br />

Features & Benefits:<br />

n System designed to meter up to 45<br />

metering points<br />

n Easy retrofit and plug-n-play<br />

expansion features<br />

n High metering accuracy up to 0.2%;<br />

standard 1.0%<br />

n Installed and configured in<br />

SIEMENS engineered Panel boards,<br />

Switchboards, and Bus Plugs at<br />

SIEMENS Plants. SIEMENS ONE<br />

SOLUTION!<br />

n Built-in HTML web pages for easy<br />

configuration & real-time data<br />

monitoring for Voltage, Current,<br />

Power, Energy, Water, and, Gas<br />

n Modbus RTU, Modbus TCP, SNMP,<br />

NTP, BACnet IP & MSTP protocols<br />

n Utilizes milliamp CT’s reducing<br />

hardware and increasing safety<br />

n Solid core CT’s for high accuracy and<br />

split core CT’s for easy retrofit.<br />

n Emailing, Alarming, Trending,<br />

Totalizing, Event Logging & Data<br />

Logging<br />

n Offline Configuration for improving<br />

Field and Factory engineering time<br />

n 4 Language support includes English,<br />

German, French, and Spanish<br />

Controller<br />

Main Controller - Directly powered from<br />

Voltage sources<br />

Main Controller - External Power Supply<br />

input 120V/125VDC for powering up the<br />

controller. Leads are available for voltage<br />

measuring Sources. Pulse output feature is<br />

not available in this variant.<br />

Meter Modules<br />

Meter - Standard Accuracy 1%<br />

with Pulse Output<br />

Meter - High Accuracy 0.2%<br />

with Pulse Output<br />

Meter Modules<br />

Meter Rack 3 Position<br />

Meter Rack 6 Position<br />

Meter Rack 9 Position<br />

Meter Rack 15 Position<br />

Meter Rack 21 Position<br />

Cables<br />

Controller to Rack Cable - 6 Inch<br />

Controller to Rack Cable - 12 Inch<br />

Controller to Rack Cable - 24 Inch<br />

Controller to Rack Cable - 36 Inch<br />

Controller to Rack Cable - 5 Foot<br />

Controller to Rack Cable - 10 Foot<br />

Controller to Rack Cable - 20 Foot<br />

Solid Core CT’s<br />

Solid Core CT 50:0.1<br />

Solid Core CT 125:0.1<br />

Solid Core CT 250:0.1<br />

Solid Core CT 400:0.1<br />

Solid Core CT 600:0.1<br />

Solid Core CT 800:0.1<br />

Solid Core CT 1200:0.1<br />

Solid Core CT 1600:0.1<br />

Solid Core CT 2000:0.1<br />

Split Core CT’s<br />

Split Core CT 50:0.1<br />

Split Core CT 125:0.1<br />

Split Core CT 250:0.1<br />

Split Core CT 400:0.1<br />

Split Core CT 600:0.1<br />

Split Core CT 800:0.1<br />

Split Core CT 1200:0.1<br />

Split Core CT 1600:0.1<br />

Split Core CT 2000:0.1<br />

Catalog Number<br />

US2:SEM3CONTROLLER<br />

US2:SEM3CONT120V<br />

US2:SEM3PLAMETER<br />

US2:SEM3PHAMETER<br />

US2:SEM3RACK3<br />

US2:SEM3RACK6<br />

US2:SEM3RACK9<br />

US2:SEM3RACK15<br />

US2:SEM3RACK21<br />

US2:SEM3CAB6INCH<br />

US2:SEM3CAB12INCH<br />

US2:SEM3CAB24INCH<br />

US2:SEM3CAB36INCH<br />

US2:SEM3CAB5FT<br />

US2:SEM3CAB10FT<br />

US2:SEM3CAB20FT<br />

US2:SEM3SCCT50<br />

US2:SEM3SCCT125<br />

US2:SEM3SCCT250<br />

US2:SEM3SCCT400<br />

US2:SEM3SCCT600<br />

US2:SEM3SCCT800<br />

US2:SEM3SCCT1200<br />

US2:SEM3SCCT1600<br />

US2:SEM3SCCT2000<br />

7KT1280-5MA00<br />

7KT1280-5MA01<br />

7KT1280-5MA02<br />

7KT1280-5MA03<br />

7KT1280-5MA04<br />

7KT1280-5MA05<br />

7KT1280-5MA06<br />

7KT1280-5MA07<br />

7KT1280-5MA08<br />

9-14<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Distribution Solutions<br />

Embedded Micro Metering Module<br />

Revised on 11/30/20<br />

Selection<br />

Meter Rack<br />

(3, 9, 15, 21)<br />

A<br />

C<br />

Meter Rack<br />

(3, 9, 15, 21)<br />

Variable Dimensions (inches)<br />

Catalog Number Description A B C<br />

US2:SEM3RACK3 3 position rack 1.900 3.570 2.282<br />

US2:SEM3RACK6 6 position rack 3.670 5.340 4.050<br />

US2:SEM3RACK9 9 position rack 5.440 7.070 5.822<br />

US2:SEM3RACK15 15 position rack 8.980 10.610 9.362<br />

US2:SEM3RACK21 21 position rack 12.520 14.150 12.902<br />

B<br />

Controller Dimensions<br />

Controller<br />

Catalog Numbers<br />

US2:SEM3CONTROLLER<br />

US2:SEM3CONT120V<br />

(For 120V Variant external powered,<br />

Pulse Output feature is not available in<br />

this variant)<br />

9 POWER<br />

MONITORING<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 9-15


Power Distribution Solutions<br />

Embedded Micro Metering Module<br />

Revised on 03/31/20<br />

Selection<br />

Current Transformer – Solid Core<br />

Dimensions (Inches)<br />

Description<br />

Catalog Number A B C D E F G<br />

Solid Core CT 50:0.1 US2:SEM3SCCT50 1.40 0.38 0.20 0.92 2.12 0.74 0.37<br />

Solid Core CT 125:0.1 US2:SEM3SCCT125 1.40 0.66 0.20 0.92 2.16 0.74 0.37<br />

Solid Core CT 250:0.1 US2:SEM3SCCT250 1.90 0.93 0.20 0.92 2.75 0.78 0.39<br />

Solid Core CT 400:0.1 US2:SEM3SCCT400 2.62 1.60 0.20 0.92 3.62 0.78 0.39<br />

Solid Core CT 600:0.1 US2:SEM3SCCT600 3.74 2.30 0.24 0.92 4.66 0.78 0.39<br />

Solid Core CT 800:0.1 US2:SEM3SCCT800 4.05 2.60 0.24 0.92 5.05 0.98 0.49<br />

Solid Core CT 1200:0.1 US2:SEM3SCCT1200 4.56 2.80 0.24 0.92 5.57 0.98 0.49<br />

Solid Core CT 1600:0.1 US2:SEM3SCCT1600 6.00 4.25 0.28 1.07 7.15 1.05 0.50<br />

Solid Core CT 2000:0.1 US2:SEM3SCCT2000 6.00 4.25 0.28 1.07 7.15 1.05 0.50<br />

Current Transformer – Solid Core<br />

A<br />

B<br />

E<br />

C<br />

G<br />

D<br />

F<br />

G<br />

Current Transformer – Split Core<br />

Description Catalog Number A B C D E F<br />

Split Core CT 50:0.1 7KT1280-5MA00 0.50 0.50 2.40 2.69 0.95 1.10<br />

Split Core CT 125:0.1 7KT1280-5MA01 0.75 0.75 2.40 2.69 0.83 0.94<br />

Split Core CT 250:0.1 7KT1280-5MA02 1.00 1.00 2.87 3.24 0.94 1.11<br />

Split Core CT 400:0.1 7KT1280-5MA03 1.50 1.50 3.60 3.75 1.05 1.15<br />

Split Core CT 600:0.1 7KT1280-5MA04 2.14 2.17 4.72 4.32 1.28 1.15<br />

Split Core CT 800:0.1 7KT1280-5MA05 3.00 3.14 5.56 5.27 1.21 1.16<br />

Split Core CT 1200:0.1 7KT1280-5MA06 3.27 3.02 6.48 5.69 1.73 1.48<br />

Split Core CT 1600:0.1 7KT1280-5MA07 4.50 4.50 7.68 7.14 1.59 1.48<br />

Split Core CT 2000:0.1 7KT1280-5MA08 4.50 4.50 7.68 7.14 1.59 1.48<br />

Current Transformer – Split Core<br />

Meter Module<br />

9<br />

POWER<br />

MONITORING<br />

Meter Module<br />

Description<br />

Meter - Standard Accuracy<br />

1% with Pulse Output<br />

Meter - High Accuracy 0.2% with<br />

Pulse Output<br />

Catalog No.<br />

US2:SEM3PLAMETER<br />

US2:SEM3PHAMETER<br />

9-16<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Distribution Solutions<br />

Embedded Micro Metering Module<br />

Selection<br />

SEM3 System configured in Panelboards<br />

The Siemens SEM3 system can be configured for factory<br />

installation in branch circuit monitoring applications using the<br />

Siemens COMPAS configuration tool. This option can lower<br />

the installation time of the system for the installer while<br />

providing a factory warrantied solution.<br />

The SEM3 system can be factory installed in unit space in<br />

type P2, P4, & P5 Siemens panel boards and SB1, SB2, &<br />

SB3 type Siemens switchboards. Please note P1 and P3<br />

configurations are not available at this time and the amount<br />

of unit space needed varies depending upon the application.<br />

Please note that lead time adders will apply and may vary<br />

depending upon the configuration of the system.<br />

SEM3 for use in Siemens Panelboards<br />

Type P2: Enclosure<br />

• Available in a NEMA 1, 3R, or 12 rated enclosure.<br />

• Minimum width & depth: 24” width x 5.75” depth<br />

• Height: Up to 74" depending on branch breaker selection<br />

– Addition of monitoring on some mains (primary and subfeed) may require additional box<br />

length. In these cases the box will be increased to the next size available as a standard<br />

design.<br />

– In cases where enclosure size is increased all multi-section panels will be increased to<br />

match the largest section.<br />

Controller<br />

SEM3 controller is mounted in unit space opposite of the feed location specified in COMPAS<br />

(i.e., bottom mount for top feed) and will require 3” of unit space. Each controller will be<br />

powered by direct tap connection to the panel section bus. Each controller can monitor up to<br />

45 circuits. Applications that require monitoring more than 45 circuits will require additional<br />

controllers.<br />

Current Transformers (CTs)<br />

Five sizes of CTs are available for use in the P2 panel: 50, 125, 250, 400 & 600 amp. All CTs<br />

are pre-mounted to a support bracket that attaches to the base rail of the interior of the panel<br />

board. Each bracket supports a maximum of 3 CTs and is designed for the breaker selected<br />

(brackets are not interchangeable between breaker frames). Each CT will be attached to a data<br />

module that is placed in the meter racks.<br />

Meter Racks<br />

Each meter rack requires 3” of unit space. All meter racks will be installed next to the SEM3<br />

controller in unit space. The COMPAS configuration tool will select the appropriate meter rack<br />

configuration according to the user’s application and will use the 21 space meter rack as a<br />

default option where possible. Only one meter rack (regardless of number of positions) can be<br />

installed in 3” of unit space.<br />

NOTE: Monitoring of 45 circuits will require 9" of unit space: two 21 position racks and one 3 position<br />

rack<br />

9 POWER<br />

MONITORING<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 9-17


Power Distribution Solutions<br />

Embedded Micro Metering Module<br />

Revised on 10/15/20<br />

Selection<br />

SEM3 System configured in Distribution Panels and Switchboards<br />

The information below pertains to panelboard types P4, P5<br />

and switchboard types SB2, and SB3. Please note SEM3 is<br />

not available for P3 panelboards or SB1 switchboards. SEM3<br />

is available in NEMA type 1, 3R, and 12 enclosures. SEM3<br />

specifics to P4, P4, SB2, and SB3 are:<br />

SEM3 for use in Siemens Switchboards<br />

Controller<br />

SEM3 controller is mounted in unit space. For P4 and P5 panels it will be mounted opposite<br />

of the feed location specified in COMPAS (i.e., bottom mount for top feed). The controller<br />

will require 3.75” of unit space in P4/5 and SB2/3. Each controller will be powered by<br />

direct tap connection to the section bus and can monitor up to 45 circuits. Applications that<br />

require monitoring more than 45 circuits will require additional controllers. For multi-section<br />

applications each controller will only be connected to meter racks in the same section as the<br />

controller.<br />

Current Transformers (CTs)<br />

Six sizes of CTs are available for use in P4/5 & SB2/3 applications: 50, 125, 250, 400, 600, 1200,<br />

1600, and 2000 amp. All CTs are pre-mounted to a support bracket that attaches to the interior.<br />

Each bracket supports a maximum of 3 CTs and is designed for the breaker selected (brackets<br />

are not interchangeable between breaker frames). Each CT will be attached to a data module<br />

that is placed in the meter racks.<br />

Meter Racks<br />

Each meter rack requires 3.75” of unit space. All meter racks will be installed next to the<br />

SEM3 controller in unit space. The COMPAS configuration tool will select the appropriate<br />

meter rack configuration according to the user’s application and will use the 21 space meter<br />

rack as a default option where possible. Only one meter rack (regardless of number of<br />

positions) can be installed in 3.75” of unit space. For multi-section applications each rack<br />

will only be connected to data modules from CTs in that section. Racks will not be setup to<br />

monitor CTs from adjacent sections.<br />

NOTE: Monitoring of 45 circuits will require 9" of unit space: two 21 position racks and one 3<br />

position rack<br />

9<br />

POWER<br />

MONITORING<br />

Other Considerations<br />

Configuration: Data modules from CTs monitoring a circuit breaker must be mounted adjacent<br />

to one another in the meter rack. Any field changes to the factory configuration must take this<br />

into account.<br />

Start-up & Commissioning: Siemens can provide these services. Contact your local<br />

SIEMENS PDS Power Solutions Business Developer for more details.<br />

Billing Services for sub billing applications: Billing services are available. Contact your local<br />

SIEMENS PDS Power Solutions Business Developer for more details.<br />

9-18<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Distribution Solutions<br />

Embedded Micro Metering Module<br />

P2 Devices<br />

Enclosure sizes<br />

Selection<br />

Example P2 Panel with SEM3 Type 1 Enclosure (24“ Wide x 5.75“ Deep)<br />

Enclosure heights are in 6“ increments from 26“ thru 74“.<br />

Enclosure heights: 26“, 32“, 38“, 44“, 50“, 56“, 62“, 68“, 74“<br />

The COMPAS configuration tool can provide actual dimensions based on the configuration.<br />

Example below is largest standard P2 enclosure for factory assembled panel<br />

with all small (1“) branch breakers installed.<br />

24" std. width<br />

Main Breaker / Main Lug space<br />

varies based on selected options<br />

Unit space varies<br />

based on selected options<br />

Note: All circuits do not have to be monitored<br />

by SEM3 - user can select any circuits in this<br />

space to be monitored.<br />

Based on smallest branch breakers and a<br />

3-phase main being monitored.<br />

There is a maximum of 63 circuits that can be<br />

monitored with the configuration shown.<br />

Some selections of main breakers and<br />

other subfeed options could limit this further.<br />

In this situation there is 30" of unit space available -<br />

so 60 branch circuits could be monitored.<br />

If monitoring the main three additional circuits could<br />

be monitored with a total of 63 circuits.<br />

This requires two controllers and three 21 position<br />

racks using 15" of unit space.<br />

- see below -<br />

SEM3 space varies by number of circuits<br />

monitored - this uses unit space.<br />

== > 6" of space for up to 21 circuits monitored<br />

one controller and one 21-pos rack<br />

== > 9" of space for up to 42 circuits monitored<br />

one controller and two 21-pos racks<br />

== > 12" of space for up to 45 circuits monitored<br />

one controller and two 21-pos racks plus one 3-pos rack<br />

9 POWER<br />

MONITORING<br />

== > 15" of space for up to 63 circuits monitored<br />

two controllers and three 21-pos racks<br />

Note: If subfeed space is needed - it will take<br />

away from available unit space.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 9-19


Power Distribution Solutions<br />

Embedded Micro Metering Module<br />

Selection<br />

P4 and P5 Devices<br />

Enclosure sizes<br />

Example P4 and P5 Panel with SEM3 Type 1 Enclosure<br />

P4 = (32“ Wide x 10“ Deep)<br />

P5 = (38“ or 46“ Wide x 10“ Deep)<br />

Enclosure heights are in 15“ increments from 60“ thru 90“.<br />

Enclosure heights: 60“, 75“, 90“ (there are optional depths also)<br />

The COMPAS configuration tool can provide actual dimensions<br />

based on the configuration. Example below is largest standard<br />

P4 enclosure for factory assembled panel - unit space is in 3.75“<br />

increments - up to 6 circuits can occupy each 3.75“ of unit space.<br />

32“ std. width for P4<br />

Main Breaker / Main Lug space<br />

varies based on selected options<br />

Unit space varies<br />

based on selected options<br />

Note: All circuits do not have to be monitored<br />

by SEM3 - user can select any circuits in this<br />

space to be monitored.<br />

Based on smallest branch breakers and a 3-phase main<br />

being monitored. There is a maximum of 63 circuits that can<br />

be monitored with the configuration shown. Some<br />

selections of main breakers and other subfeed options could<br />

limit this further.<br />

In this situation there is 37.5" of unit space available -<br />

so 60 branch circuits could be monitored.<br />

If monitoring the main three additional circuits could<br />

be monitored with a total of 63 circuits.<br />

9<br />

POWER<br />

MONITORING<br />

This requires two controllers and three 21 position<br />

racks using 18.75" of unit space.<br />

- see below -<br />

SEM3 space varies by number of circuits<br />

monitored - this uses unit space.<br />

== > 7.5" of space for up to 21 circuits monitored<br />

one controller and one 21-pos rack<br />

== > 11.25" of space for up to 42 circuits monitored<br />

one controller and two 21-pos racks<br />

== > 15" of space for up to 45 circuits monitored<br />

one controller and two 21-pos racks plus one 3-pos rack<br />

== > 18.75" of space for up to 63 circuits monitored<br />

two controllers and three 21-pos racks<br />

Note: If subfeed space is needed - it will take<br />

away from available unit space.<br />

9-20<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Distribution Solutions<br />

Enclosures for External Applications<br />

Revised on 02/28/19<br />

Selection<br />

Standard Enclosures for External Applications<br />

Typical SEM3 with<br />

display example<br />

The SEM3 standalone enclosure is<br />

ideal for retrofit/external wall mount<br />

applications, as it requires minimal<br />

modification of existing systems while<br />

gaining full functionality of the SEM3<br />

branch circuit monitoring solution.<br />

Installation of the required milliamp<br />

current transformers (CT) is minimized<br />

by utilizing the Siemens Split Core CTs<br />

ranging from 50 to 2000 Amps. See<br />

“Split Core CT” section.<br />

SEM3 standard enclosures are available<br />

with NEMA 1, 4 and 12 ratings. The<br />

SEM3 meter enclosure is shipped<br />

with all the required components<br />

installed. The control voltage is wired<br />

to a fusible disconnect switch to<br />

protect the system and to provide a<br />

disconnect from outside power to the<br />

meter. SEM3 Solid Core CTs are self<br />

shorting, not requiring a shorting block<br />

in the enclosure/panel.Shorting blocks<br />

are recommended for SEM3 Split<br />

Core CT’s installed in an enclosure/<br />

panel. The enclosure has a ground lug<br />

for equipment grounding. When the<br />

control voltage is greater than 480<br />

volts, a CPT is provided between the<br />

disconnect switch and SEM3 controller.<br />

The enclosure is pre-drilled to make<br />

mounting quick and easy.<br />

The standard enclosure comes with the<br />

controller, power supply, disconnect,<br />

meter racks, communication cables,<br />

and shorting blocks. Meter modules<br />

and CTs are added separately. As<br />

mentioned previously, the display is<br />

available as an option.<br />

No Display Standard Enclosure for External Application – HMI, SEM3 Meter Modules, and CT’s are not included<br />

Description<br />

Catalog Numbers<br />

SEM3 3M ENCL Type 1 16T x 12W X 6D<br />

US2:SEM303ENCL1<br />

SEM3 3M ENCL Type 12 16T x 12W X 6D<br />

US2:SEM303ENCL12<br />

SEM3 3M ENCL Type 4 16T x 12W X 6D<br />

US2:SEM303ENCL4<br />

SEM3 9M ENCL Type 1 16DT x 12W X 6D<br />

US2:SEM309ENCL1<br />

SEM3 9M ENCL Type 12W 16DT x 12W X 6D<br />

US2:SEM309ENCL12<br />

SEM3 9M ENCL Type 4 16DT x 12W X 6D<br />

US2:SEM309ENCL4<br />

SEM3 15M ENCL Type 1 16DT x 12W X 6D<br />

US2:SEM315ENCL1<br />

SEM3 15M ENCL Type 12W 16DT x 12W X 6D<br />

US2:SEM315ENCL12<br />

SEM3 15M ENCL Type 4 16DT x 12W X 6D<br />

SEM3 18M ENCL Type 1 20T x 12W x 6D<br />

SEM3 18M ENCL Type 12W 20T x 12W x 6D<br />

SEM3 18M ENCL Type 4 20T x 12W x 6D<br />

SEM3 21M ENCL Type 1 20T x 12W x 6D<br />

SEM3 21M ENCL Type 12W 20T x 12W x 6D<br />

SEM3 21M ENCL Type 4 20T x 12W x 6D<br />

SEM3 30M ENCL Type 1 20T x 16W x 6.62D<br />

SEM3 30M ENCL Type 12W 20T x 16W x 6.62D<br />

US2:SEM315ENCL4<br />

US2:SEM318ENCL1<br />

US2:SEM318ENCL12<br />

US2:SEM318ENCL4<br />

US2:SEM321ENCL1<br />

US2:SEM321ENCL12<br />

US2:SEM321ENCL4<br />

US2:SEM330ENCL1<br />

US2:SEM330ENCL12<br />

SEM3 Enclosure<br />

without display<br />

9 POWER<br />

MONITORING<br />

SEM3 30M ENCL Type 4 20T x 16W x 6.62D<br />

US2:SEM330ENCL4<br />

SEM3 42M ENCL Type 1 20T x 16W x 6.62D<br />

US2:SEM342ENCL1<br />

SEM3 42M ENCL Type 12W 20T x 16W x 6.62D<br />

US2:SEM342ENCL12<br />

SEM3 42M ENCL Type 4 20T x 16W x 6.62D<br />

US2:SEM342ENCL4<br />

SEM3 45M ENCL Type 1 20T x 16W x 6.62D<br />

US2:SEM345ENCL1<br />

SEM3 45M ENCL Type 12W 20T x 16W x 6.62D<br />

SEM3 45M ENCL Type 4 20T x 16W x 6.62D<br />

US2:SEM345ENCL12<br />

US2:SEM345ENCL4<br />

SEM3 Enclosure without meter<br />

modules installed<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 9-21


Power Distribution Solutions<br />

Enclosures for External Applications<br />

Selection<br />

Standard Enclosure with HMI Display & Switch for External Application – SEM3 Meter Modules, and CT’s are not included<br />

Description<br />

SEM3 3M w/display/switch 16 x 16 x 6.5<br />

SEM3 3M w/display 16 x 16 x 6.5<br />

SEM3 9M w/display/switch 16 x 16 x 6.5<br />

SEM3 9M w/display 16 x 16 x 6.5<br />

SEM3 15M w/display/switch 20 x 16 x 8<br />

SEM3 15M w/display 20 x 16 x 8<br />

SEM3 18M w/display/switch 20 x 16 x 8<br />

SEM3 18M w/display 20 x 16 x 8<br />

SEM3 21M w/display/switch 20 x 16 x 8<br />

SEM3 21M w/display 20 x 16 x 8<br />

SEM3 30M w/display/switch 20 x 20 x 8<br />

SEM3 30M w/display 20 x 20 x 8<br />

SEM3 42M w/display/switch 20 x 20 x 8<br />

SEM3 42M w/display 20 x 20 x 8<br />

SEM3 45M w/display/switch 20 x 20 x 8<br />

SEM3 45M w/display 20 x 20 x 8<br />

Catalog Numbers<br />

US2:SEM303ENCL1DS<br />

US2:SEM303ENCL1D<br />

US2:SEM309ENCL1DS<br />

US2:SEM309ENCL1D<br />

US2:SEM315ENCL1DS<br />

US2:SEM315ENCL1D<br />

US2:SEM318ENCL1DS<br />

US2:SEM318ENCL1D<br />

US2:SEM321ENCL1DS<br />

US2:SEM321ENCL1D<br />

US2:SEM330ENCL1DS<br />

US2:SEM3301ENCL1D<br />

US2:SEM342ENCL1DS<br />

US2:SEM342ENCL1D<br />

US2:SEM345ENCL1DS<br />

US2:SEM345ENCL1D<br />

Remote Touch Display Enclosure Package - No SEM3 parts included<br />

Description<br />

SEM3 ENCL 7” Touch Display 24 VDC/1.3 Amp Power Supply<br />

SEM3 ENCL 7” Touch Display 24 VDC/1.3 Amp PS UL Listed<br />

SEM3 ENCL 7” Touch Display 24 VDC/1.3 Amp PS + 8 Port Switch<br />

Catalog Numbers<br />

US2:SEM3TP7SEN<br />

US2:SEM3TP7SENUL<br />

US2:SEM3TP7AEN<br />

SEM3 ENCL 7” Touch Display 24 VDC/1.3 Amp PS +<br />

8 Port Switch UL Listed<br />

US2:SEM3TP7AENUL<br />

SEM3 ENCL 9” Touch Display 24 VDC/1.3 Amp Power Supply US2:SEM3TP9SEN<br />

SEM3 ENCL 9” Touch Display 24 VDC/1.3 Amp PS UL Listed US2:SEM3TP9SENUL<br />

SEM3 ENCL 9” Touch Display 24 VDC/1.3 Amp PS + 8 Port Switch US2:SEM3TP9AEN<br />

SEM3 ENCL 9” Touch Display 24 VDC/1.3 Amp PS +<br />

8 Port Switch UL Listed<br />

US2:SEM3TP9AENUL<br />

SEM3 ENCL 12” Touch Display 24 VDC/1.3 Amp Power Supply US2:SEM3TP12SEN<br />

SEM3 ENCL 12” Touch Display 24 VDC/1.3 Amp PS UL Listed US2:SEM3TP12SENUL<br />

SEM3 ENCL 12” Touch Display 24 VDC/1.3 Amp PS +<br />

8 Port Switch<br />

US2:SEM3TP12AEN<br />

SEM3 ENCL 12” Touch Display 24 VDC/1.3 Amp PS +<br />

8 Port Switch UL Listed<br />

US2:SEM3TP12AENUL<br />

Optional Loose Remote Touch Display and Power Supply<br />

Description<br />

Catalog Numbers<br />

SEM3 7” TD 100-240VAC + SITOP PS 24VDC<br />

US2:SEM3TOUCHP7<br />

9<br />

POWER<br />

MONITORING<br />

SEM3 9” TD 100-240VAC + SITOP PS 24VDC<br />

SEM3 12” TD 100-240VAC + SITOP PS 24VDC<br />

SEM3 15” TD 100-240VAC + SITOP PS 24VDC<br />

SEM3 19” TD 100-240VAC + SITOP PS 24VDC<br />

US2:SEM3TOUCHP9<br />

US2:SEM3TOUCHP12<br />

US2:SEM3TOUCHP15<br />

US2:SEM3TOUCHP19<br />

9-22<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Distribution Solutions<br />

MD Series Power Meter<br />

MD BM and MD BMD Model Power Meters<br />

Siemens Industry’s MD BM and MD BMD Model Power<br />

Meters are sub metering devices designed to provide real<br />

time, accurate electricity metering to enable proper control<br />

over energy costs. The meter can capture kWh/kW energy<br />

and demand data, as well as virtually all relevant energy<br />

parameters for diagnostics and monitoring on three-phase<br />

or single- phase circuit installations. The meters’ flexibility,<br />

size, and ease-of-use make them ideal tools for gathering<br />

detailed consumption information in commercial, industrial,<br />

governmental, and retail environments. The meters use<br />

direct connections to each phase of the voltage and various<br />

interchangeable current transformer (CT) options such as splitcore<br />

CTs or flexible Rogowski Coils (for large loads or large<br />

cables and buss bars) to monitor current on each phase. All<br />

of Siemens’ current transformers are internally shunted for<br />

intrinsically safe operation on energized conductors.<br />

The power meters make over 75 total electrical<br />

measurements which are derived from the voltage and<br />

current inputs. Electrical load diagnostic parameters such<br />

as power factor and line frequency are captured in addition<br />

to energy and demand values. The Siemens MD BM and<br />

MD BMD Power Meters require no external power and the<br />

power supplies can accommodate service voltages ranging<br />

from 80 to 600V (phase-to-phase). The simple installation is<br />

accomplished by connecting the color-coded voltage leads<br />

and clearly labeled CTs. A three-LED indicator display confirms<br />

proper CT-to-phase installation. The meters automatically<br />

adjust for CT orientation—greatly reducing set-up time and all<br />

but eliminating installation errors.<br />

Product Description<br />

MD Meter BACnet-Modbus<br />

MD Meter Modbus-BACnet IP<br />

MD Meter BACnet-Modbus w/display<br />

MD Meter Modbus-BACnet IP w/display<br />

Mini SplitCore 0.4 Opening 50A<br />

Mini SplitCore 0.4 Opening 100A<br />

Mini SplitCore 0.4 Opening 200A<br />

Small SplitCore 0.75 Opening 50A<br />

Small SplitCore 0.75 Opening 100A<br />

Medium SplitCore 1.25 Opening 100A<br />

Medium SplitCore 1.25 Opening 200A<br />

Medium SplitCore 1.25 Opening 400A<br />

Medium SplitCore 1.25 Opening 600A<br />

Large SplitCore 2.00 Opening 600A<br />

Large SplitCore 2.00 Opening 1000A<br />

Rogowski Coil Current Transformer, 16” (40 cm); 4.5” (11.5 cm) opening; 4000A<br />

Rogowski Coil Current Transformer, 24” (60 cm); 7.0” (18 cm) opening; 4000A<br />

Rogowski Coil Current Transformer, 36” (90 cm); 10.8 (28 cm) opening; 4000A<br />

Catalog Number<br />

US2:MDBM<br />

US2:MDBMIP<br />

US2:MDBMD<br />

US2:MDBMIPD<br />

US2:SCTHSC0050U<br />

US2:SCTHMC0100U<br />

US2:SCTHMC0200U<br />

US2:SCTSCS0050U<br />

US2:SCTSCS0100U<br />

US2:SCTSCM0100U<br />

US2:SCTSCM0200U<br />

US2:SCTSCM0400U<br />

US2:SCTSCM0600U<br />

US2:SCTSCL0600U<br />

US2:SCTSCL1000U<br />

US2:SCTR161310U<br />

US2:SCTR241310U<br />

US2:SCTR361310U<br />

9 POWER<br />

MONITORING<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 9-23


Power Distribution Solutions<br />

Revised on 03/31/20<br />

Low-voltage Current Transformers<br />

Comprehensive metering grade CT offering spilt-core, flexible and solid core designs<br />

Split core – Rectangular Window<br />

Siemens Instrument Grade Current Transformers<br />

(CT) have a split-core construction and provide<br />

a safe 5A secondary output. These split-core<br />

current transformers allow for easy installation,<br />

retrofit, and service. CT’s come with 4’ leads<br />

(18 gauge). Use on low-voltage applications of<br />

600V or less.<br />

Accuracy 1.0%.<br />

200A – 300A 400A – 800A 1000A – 1200A<br />

A = 3.75” (95mm) A = 4.90” (124mm) A = 4.90” (124mm)<br />

B = 1.51” (38mm) B = 2.89” (73mm) B = 5.50” (140mm)<br />

C = 1.25” (32mm) C = 2.45” (62mm) C = 2.45” (62mm)<br />

D = 1.13” (29mm) D = 1.13” (29mm) D = 1.13” (29mm)<br />

E = 4.20” (107mm) E = 5.57” (141mm) E = 8.13” (207mm)<br />

F = 4.75” (121mm) F = 5.91” (150mm) F = 5.92” (150mm)<br />

Amps<br />

Window<br />

(C x B) Catalog Number<br />

200A 1.25”x1.51” PDS-CTSC-021<br />

300A 1.25”x1.51” PDS-CTSC-031<br />

400A 2.45”x2.89” PDS-CTSC-042<br />

600A 2.45”x2.89” PDS-CTSC-062<br />

800A 2.45”x2.89” PDS-CTSC-083<br />

1000A 2.45”x5.50” PDS-CTSC-013<br />

1200A 2.45”x5.50” PDS-CTSC-123<br />

1600A 2.45”x5.50” PDS-CTSC-163<br />

2000A 2.45”x5.50” PDS-CTSC-200<br />

3000A 2.75”x6.625” PDS-CTSC-03R<br />

Split-core – Round Window<br />

Split-core round rubber insulated flexible CT’s with<br />

12’ heavy duty leads (18 AWG) and 5A secondary<br />

output for use on low-voltage applications of 600V.<br />

Accuracy is 4% for 200/300A, 3% for 400A, and<br />

2% for 600A/800A and 1% for 1200A and above.<br />

9<br />

POWER<br />

MONITORING<br />

200A – 1200A<br />

3000A – 4000A<br />

A = 4.00” A = 6.00”<br />

B = 1.25” B = 1.25”<br />

C = 1.50” C = 1.50”<br />

D = 6.50” D = 8.50”<br />

Amps<br />

Window<br />

(A)<br />

Catalog Number<br />

200A 4.00” PDS-CTHC-024<br />

300A 4.00” PDS-CTHC-034<br />

400A 4.00” PDS-CTHC-044<br />

600A 4.00” PDS-CTHC-064<br />

800A 4.00” PDS-CTHC-084<br />

1200A 4.00” PDS-CTSC-123<br />

2000A 6.00” PDS-CTHC-206<br />

3000A 6.00” PDS-CTHC-306<br />

4000A 6.00” PDS-CTHC-406<br />

9-24<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category PDS


Power Distribution Solutions<br />

Revised on 03/31/20<br />

Low-voltage Current Transformers<br />

Comprehensive metering grade CT offering spilt-core, flexible and solid core designs<br />

Solid-core – Round with Round Window<br />

Solid-core – Square with Round Window<br />

The small size<br />

solid core Current<br />

Transformer (CT) are<br />

designed for tight<br />

locations and new<br />

installations providing<br />

a safe 5 amp<br />

secondary for use on<br />

voltage applications<br />

of 600V or less.<br />

Accuracy is 1.2% for<br />

100A, 0.3% for 200A<br />

and up.<br />

Solid core – Round metering grade, 600V<br />

Catalog Number Primary Size<br />

SMU-CT-011 100A 1.75” x 2.47”, 1” Window<br />

SMU-CT-021 200A 1.75” x 2.47”, 1” Window<br />

SMU-CT-025 250A 1.75” x 2.47”, 1” Window<br />

SMU-CT-031 300A 1.75” x 2.47”, 1” Window<br />

SMU-CT-041 400A 1.1” x 3.56”, 1.56” Window<br />

SMU-CT-061 600A 1.1” x 3.56”, 1.56” Window<br />

SMU-CT-081 800A 1.1” x 3.56”, 1.56” Window<br />

SMU-CT-123 1000A 1.1” x 3.56”, 1.56” Window<br />

SMU-CT-02R 2000A 1.15” x 5.73”, 3.25” Window<br />

Siemens Instrument<br />

Grade Current<br />

Transformers (CT) are<br />

designed as solid-core<br />

construction and provide<br />

a safe 5A secondary<br />

output. Solid-core CT’s<br />

come with terminals for<br />

attaching leads. Use on<br />

low-voltage applications<br />

of 600V or less.<br />

Amps Dimension (A x B x C x D) Accuracy Catalog Number<br />

200:5 1.25” x 4.88” x 2.19” x 4.68” 0.1% PDS-CTRC-021<br />

300:5 1.25” x 4.88” x 2.19” x 4.68” 0.1% PDS-CTRC-031<br />

400:5 1.25” x 4.88” x 2.19” x 4.68” 0.1% PDS-CTRC-041<br />

500:5 1.25” x 5.10” x 3.00” x 5.50” 0.1% PDS-CTRC-051<br />

600:5 1.25” x 5.10” x 3.00” x 5.50” 0.1% PDS-CTRC-061<br />

800:5 1.25” x 5.10” x 3.00” x 5.50” 0.1% PDS-CTRC-081<br />

1000:5 1.25” x 5.10” x 3.00” x 5.50” 0.1% PDS-CTRC-101<br />

100:5 2.25” x 6.31” x 3.00” x 5.82” 0.6% PDS-CTRC-012<br />

200:5 2.25” x 6.31” x 3.00” x 5.82” 0.3% PDS-CTRC-022<br />

300:5 2.25” x 6.31” x 3.00” x 5.82” 0.3% PDS-CTRC-032<br />

400:5 2.25” x 6.31” x 3.00” x 5.82” 0.3% PDS-CTRC-042<br />

800:5 4.00” x 6.44” x 3.25” x 3.25” 0.3% PDS-CTRC-084<br />

1000:5 4.00” x 6.44” x 3.25” x 3.25” 0.3% PDS-CTRC-104<br />

1200:5 4.00” x 6.44” x 3.25” x 3.25” 0.3% PDS-CTRC-124<br />

1600:5 4.00” x 6.44” x 3.25” x 3.25” 0.3% PDS-CTRC-164<br />

2000:5 4.00” x 6.44” x 3.25” x 3.25” 0.3% PDS-CTRC-204<br />

3200:5 6.50” x 9.88” x 7.00” x 7.00” 0.3% PDS-CTRC-326<br />

4000:5 6.50” x 9.88” x 7.00” x 7.00” 0.3% PDS-CTRC-426<br />

Shorting Block<br />

All low-voltage current transformers should be installed with a<br />

shorting block to allow for easy removal of the metering unit<br />

and to provide a safe method for disconnecting the CT signal.<br />

One shorting block is required per meter. Various size shorting<br />

blocks are available; 4, 6, and 8 pole configurations are available<br />

with four slotted shorting screws and cover. Wire size is<br />

18-10 AWG.<br />

Catalog<br />

Mounting<br />

Number Ckts. L D min. D max.<br />

IKU4SC 4 3.25 2.88 3.00<br />

IKU6SC 6 4.50 4.12 4.25<br />

IKU8SC 8 5.75 5.38 5.50<br />

IKU12SC 12 8.25 7.88 8.00<br />

Typical electrical meter CT and shorting<br />

block installation<br />

This example<br />

shows a common<br />

three phase, three<br />

wire installation<br />

where three CT’s<br />

and one shorting<br />

block are used.<br />

9 POWER<br />

MONITORING<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 9-25


Power Distribution Solutions<br />

SEM3T — Reliable Thermal Sensing in electrical equipment<br />

Revised on 10/15/20<br />

Introduction<br />

Avoid downtime with 24/7 continuous monitoring via SIEMENS SEM3T Thermal Monitoring<br />

SEM3T Thermal<br />

Monitoring System<br />

Selection and Application Guide<br />

For many years, scheduled infrared<br />

thermography (IR) inspections have<br />

been the accepted method for<br />

reducing risk of fire by identifying<br />

faulty or loose connections in electrical<br />

distribution systems. SEM3T is a<br />

system specifically designed to provide<br />

continuous thermal monitoring. It offers<br />

a safer, more effective way to detect<br />

thermal risks before they progress into<br />

a major failure.<br />

The method also delivers up to a 10:1<br />

return on investment due to avoided<br />

equipment damage and downtime.<br />

Continuous Thermal Monitoring is now<br />

enabling safer, more efficient inspection<br />

of energized electrical equipment,<br />

ensuring electrical asset integrity. This<br />

becomes apparent when looking at the<br />

technology comparison of SEM3T to IR<br />

windows and thermal imaging.<br />

To meet the thermal monitoring<br />

challenges of operations owner,<br />

design engineers, and contractors,<br />

Siemens offers a proven cost-effective<br />

solution for Thermal Monitoring. This<br />

solution combines a fully integrated<br />

thermal monitoring system factory<br />

installed into the Siemens Panelboards,<br />

Switchboards, and Switchgears, which<br />

along with the required local or remote<br />

monitoring software, provides a “Total”<br />

Power and Thermal monitoring system.<br />

9<br />

POWER<br />

MONITORING<br />

Siemens Thermal Monitoring/<br />

Embedded Monitoring Solution<br />

n Saves you money – SIEMENS SEM3T thermal monitoring<br />

system specifically designed to provide 24x7 detection of<br />

hotspots at an early stage of development; thus, avoiding<br />

potential downtime resulting from Arc Flash / power outage<br />

incidents.<br />

n Fast, low-cost installation – The embedded Siemens<br />

solution provides a faster and lower cost installation<br />

compared to other external systems.<br />

n Safety in mind – SIEMENS thermal monitoring system<br />

is safer, more effective way to detect thermal risks before<br />

they progress into a major failure.<br />

n Minimum space requirements – The embedded switchgear,<br />

switchboard and panelboard construction design requires no<br />

additional wall space to provide thermal monitoring.<br />

n Reliable and accurate – SIEMENS thermal monitoring<br />

system is non-invasive reliable and easily installed thermal<br />

monitoring solution which can monitor numerous locations<br />

within low voltage apparatus including bus joints, lug<br />

landings, bus ducts, transformers, and circuit breakers.<br />

Thermal sensors can be positioned appropriately to detect<br />

ambient temperature, as well as overloaded or poorly<br />

conducting electrical connections.<br />

n Automated alert notifications – With automated alert<br />

notification services the responsibility to acquire the data,<br />

store the data and analyze the data is removed from the<br />

facility management company, thus saving manpower and<br />

time.<br />

n Responsive service – With remote monitoring, continuous<br />

24/7 monitoring can be done by the facility management<br />

company or local users. The service can also relay thermal<br />

hotspot conditions changes to the owners for immediate<br />

investigation.<br />

Designer and Contractor benefits include:<br />

n No need to wait for inspector to scan the system to<br />

understand abnormalities<br />

n Factory pre-wired – less installation time<br />

n Drastically less installation wiring & cost<br />

n Thermal sensors are calibrated to meet the accuracy<br />

standards and requirements<br />

n All equipment fits into the standard Siemens electrical<br />

equipment design<br />

n UL, CE (Pending) approved<br />

n Embedded web-server for on-site configuration, real time<br />

data display, data logging, event logging, trending and alarm<br />

notifications.<br />

n Built-in industry standard Modbus TCP communication<br />

n Dual Ethernet ports for daisy chaining over Ethernet and<br />

Wi-Fi as an option<br />

n Monitor 1 to 45 thermal points.<br />

n Web pages can also be set by a user to four different<br />

languages (English, German, French, or Spanish) for<br />

configurations and real-time data display<br />

Thermal Monitoring applications include:<br />

n Industrial Manufacturing<br />

n Critical Power - Data Centers and Hospitals<br />

n Government<br />

n LEEDS buildings<br />

n Airports<br />

n Higher Education<br />

Please Contact Your Siemens Sales Engineer for additional information regarding Thermal Sensing:<br />

9-26<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Distribution Solutions<br />

SEM3T<br />

Revised on 10/15/20<br />

Overview<br />

SEM3T System Overview<br />

Inside electrical apparatus equipment<br />

1. Main Controller<br />

2. Rack to Controller Cables<br />

3. Thermal Sensors<br />

4. Thermal Module<br />

5. Racks<br />

0... 80% up to 31º C<br />

0... 50% at 40º C<br />

IP20<br />

14º...149º F<br />

-10º...65º C<br />

SEM3T Controller<br />

SEM3T Controller can provide thermal monitoring for up to 45<br />

Thermal points. SEM3T Controller acts as a Data Server and<br />

processes the data from the Thermal Modules. The controller<br />

can be configured to create several groups with multiple<br />

thermal points. This information either viewed in real-time or<br />

communicated to other systems through its communication<br />

interfaces. Some applications may require for more than 45<br />

thermal points in one apparatus electrical equipment. If so,<br />

then simply add a second controller. Two controllers can<br />

monitor up to 90 thermal points. Using the available dual<br />

Ethernet ports in each controller, daisy chaining of multiple<br />

controllers in a serial fashion is achievable.<br />

n SEM3T Controller has built-in web pages for real-time data,<br />

historical logging/trending, alarm notifications, KPI dash<br />

boards, and configurations<br />

n Easy to integrate to Siemens MindSphere cloud platform –<br />

MindSphere ready device<br />

n 24vdc power supply<br />

n Optional Wi-Fi<br />

n Available standard communication protocol: Modbus TCP<br />

for integration with monitoring software system, SMTP for<br />

emailing, and NTP for network time synchronization<br />

n Dual Ethernet (RJ45) ports for daisy chain over Ethernet<br />

n Meets global certifications/ standards<br />

SEM3T Thermal Module<br />

The Thermal Module reads the address from the racks<br />

designated by its location and thermal signals from its<br />

respective thermal sensor. Each Thermal Module is an<br />

independent thermal module that samples thermal signals,<br />

processes these signals using the embedded algorithms and<br />

communicates these parameters to the controller. When the<br />

thermal module is powered and is communicating properly<br />

with the controller, the power LED will blink.<br />

n One thermal module per thermal monitoring location<br />

n No configuration required for the modules<br />

n Connects directly to thermal sensors<br />

SEM3T Thermal Sensors<br />

Thermal Sensors are components used for thermal<br />

measurement. SEM3T product is UL listed. Thermal Sensor<br />

lead wires come with standard 10’ can be extended up to<br />

50’, still maintaining the thermal output accuracy.<br />

n Thermal Sensors are designed to work specifically with the<br />

SEM3T product<br />

n Lead wire type: UL rated operating temperature to 200ºC,<br />

600V rated, UL style 1199, 18AWG, 10 x 30 stranded<br />

n Primary rating: 600VAC<br />

n Overvoltage category: CAT IV<br />

n Operating temperature 0ºC to 130ºC<br />

n Very reliable non-powered wired Sensors are designed to<br />

withstand harsh environments Thermal Sensors come in the<br />

following variants and sizes:<br />

n 4 types Sensor Screw Ring terminals for monitoring thermal<br />

points at joint locations<br />

n Sensor S-Ring sizes: 1/4”, 5/16”, 3/8”, 1/2”<br />

n Cylindrical sensor for monitoring ambient temperature<br />

Sensor C-Ring<br />

SEM3 Racks<br />

The SEM3 Racks are the holders for the thermal modules.<br />

Embedded within a rack is the internal addressing for the<br />

communication of thermal information from the module to<br />

the controller via Ethernet cables. A two-way DIP switch<br />

is available on the 9, 15, and 21 position racks for thermal<br />

monitoring addressing, whereas a rotary switch is available to<br />

set the addressing on 3 and 6 position racks.<br />

n Five types of racks available<br />

n DIP switch or rotary switch for controller to recognize<br />

module location and rack assignments<br />

Rack to Controller Cables<br />

The communications cables connect the SEM3 racks to the<br />

controller and daisy chain additional meter racks together<br />

in series (for 3 and/or 6 meter module racks only). Multiple<br />

lengths are available to suit a wide variety of panelboard and<br />

switchboard configurations. The data cables are insulated<br />

for 600V applications and are not standard Ethernet cables.<br />

NOTE: See ordering information page for cable sizes and<br />

catalog numbers.<br />

n Seven cable lengths<br />

n 600V rated Ethernet cable. Note: Regular Ethernet RJ45<br />

cables are rated only up to 300V and are not allowed to use<br />

for this application<br />

9 POWER<br />

MONITORING<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 9-27


POWER POWER<br />

POWER<br />

POWER POWER<br />

Power Distribution Solutions<br />

SEM3T<br />

Revised on 10/15/20<br />

Selection and Application Guide | SEM3T<br />

Selection and Application Guide | SEM3T<br />

Ordering Selection and and and Application technical Guide data | | | SEM3T<br />

SEM3T Controller<br />

Ordering information<br />

Part<br />

SEM3T Controller with Wi-Fi<br />

SEM3T Controller without Wi-Fi<br />

Catalog Number<br />

7KT1281-0AA10<br />

7KT1281-0AA00<br />

2.41in<br />

[61.21mm] 2.41in<br />

[61.21mm]<br />

2.41in<br />

2.09in<br />

[61.21mm]<br />

[53.09mm] 2.09in<br />

[53.09mm]<br />

2.09in<br />

[53.09mm]<br />

1.84in<br />

[46.74mm] 1.84in<br />

[46.74mm]<br />

1.84in<br />

[46.74mm]<br />

Controller<br />

ETHERNET SD ETHERNET<br />

PORT 1<br />

PORT 2<br />

ETHERNET SD ETHERNET<br />

PORT 1<br />

PORT 2<br />

ETHERNETSDSD<br />

SD<br />

ETHERNET<br />

PORT PORT 1PORT 1 1<br />

PORT PORT 2PORT 2 2<br />

Description<br />

Altitude / Elevation<br />

Humidity<br />

Operating<br />

Temperature Range<br />

Power Supply<br />

Requirement<br />

24 V DC<br />

power supply leads<br />

Thermal<br />

Sensor Leads<br />

Information<br />

3000 Meters/9843 Feet<br />

Maximum relative humidity 80% for<br />

temperature up to 31°C decreasing linearly<br />

to 50% relative humidity at 40°C<br />

-10°C to +65°C / 14°F to 149°F<br />

UL Listed 24V DC Class II power supply.<br />

IN-LBS<br />

[Nm] IN-LBS mm 2 mm 2 AWG<br />

[Nm] IN-LBS mm 2 mm 2 AWG<br />

[Nm] [Nm]<br />

mm 2 mm 2 2<br />

mm mm 2 2<br />

AWG<br />

2 AWG<br />

5 [.56] .50 to 2.50 22 to 14<br />

1.7 [.19] 0.75 18<br />

mm 2 mm 2 mm mm 2 2 2<br />

SEM3T Controller<br />

(Thermal SEM3T Monitoring System) Controller<br />

Model No: 7KT1281-0AA1 0<br />

(Thermal Monitoring System)<br />

SEM3T<br />

Model No: <br />

7KT1281-0AA1<br />

Controller<br />

0<br />

DEVICE<br />

(Thermal Monitoring System) System)<br />

Model ETHERNEDEVICE<br />

Model No: Model No: No: 7KT1281-0AA1 T 0 0 0<br />

SD CAR ETHERNE D T<br />

DEVICE<br />

SD CAR D<br />

ETHERNE T T T<br />

SD SD SD CARD<br />

CAR D D<br />

Siemens Industry, Inc.<br />

Norcross,<br />

Siemens<br />

GA USA<br />

Industry, Inc.<br />

www.usa.siemens.com/SEM3T<br />

Norcross, GA USA<br />

www.usa.siemens.com/SEM3T<br />

Siemens Siemens Industry, Industry, Inc. Inc. Inc.<br />

WIFI MAC: XX:XX:XX:XX:XX:XX<br />

Norcross, Norcross, GA GA USA USA GA USA<br />

LAN MAC: XX:XX:XX:XX:XX:XX<br />

WIFI MAC: XX:XX:XX:XX:XX:XX<br />

www.usa.siemens.com/SEM3T<br />

LAN MAC: XX:XX:XX:XX:XX:XX<br />

Contains Transmitter Module FCC ID: TFB-TIWI1-01<br />

Contains Transmitter WIFI WIFI MAC: WIFI MAC: MAC: Module XX:XX:XX:XX:XX:XX<br />

IC: 5969A-TIWI101<br />

Contains Transmitter Module FCC ID: TFB-TIWI1-01<br />

LAN LAN MAC: MAC: LAN MAC: XX:XX:XX:XX:XX:XX<br />

Contains Transmitter Module IC: 5969A-TIWI101<br />

C<br />

Contains Contains US<br />

Transmitter Module Module FCC FCC ID: FCC ID: ID: TFB-TIWI1-01<br />

Contains Contains Transmitter Module Module IC: IC: IC: 5969A-TIWI101<br />

LISTEDC<br />

US<br />

E499865<br />

THERMAL MONITOR<br />

C CLISTED<br />

C US US US<br />

E499865<br />

THERMAL MONITOR<br />

24Vdc<br />

LISTED LISTED<br />

CLASS 2, 300 mA<br />

E499865 E499865 E499865<br />

THERMAL THERMAL MONITOR THERMAL<br />

24Vdc WiFi<br />

MONITOR MONITOR<br />

(-) (+) CLASS 2, 300 mA<br />

RACK(S)<br />

ANT WiFi<br />

(-) RACK(S)<br />

24Vdc<br />

(+)<br />

24Vdc ANT<br />

CLASS CLASS 2, 300 CLASS 2, 300 mA mA 2, 300 mA<br />

WiFi WiFi WiFi<br />

(-) (-) (+) (+) (-) (+)<br />

RACK(S) RACK(S)<br />

ANT ANT ANT<br />

Hole Dimensions<br />

Hole Dimensions 1.08in<br />

2x Ø .177 [4.50mm] 1.08in<br />

2x Hole Hole Ø .177 Dimensions [4.50mm] [27.43mm]<br />

[27.43mm]<br />

1.08in<br />

2x 2x 2x Ø Ø .177 .177 [4.50mm]<br />

[27.43mm]<br />

4.49in<br />

[114.05mm] 4.49in<br />

[114.05mm]<br />

4.11in<br />

4.49in<br />

[104.39mm] 4.11in<br />

[114.05mm]<br />

[104.39mm]<br />

4.11in<br />

[104.39mm]<br />

.35in<br />

[8.89mm] .35in<br />

[8.89mm] .35in .35in<br />

[8.89mm]<br />

SEM3T Thermal Module<br />

Ordering information<br />

Part<br />

SEM3T Sensor Module<br />

Catalog Number<br />

7KT1281-1AA00<br />

Thermal Module<br />

Description<br />

Information<br />

Altitude / Elevation 3000 Meters/9843 Feet<br />

Pollution Degree 3 (UL 61010)<br />

Overvoltage Category IV (UL 61010)<br />

Operating<br />

Temperature Range<br />

-10°C to +65°C / 14°F to 149°F<br />

SENSOR MODULE<br />

9<br />

SEM3T SEM3T<br />

SEM3T<br />

SEM3T SEM3T<br />

SENSOR MODULE<br />

SENSOR MODULE<br />

SENSOR SENSOR MODULE MODULE<br />

POWER<br />

MONITORING<br />

1.59 in<br />

[4.39mm] 1.59 in<br />

[4.39mm] 1.59 1.59 in in in<br />

[4.39mm]<br />

1.7 IN-LBS [0.19 Nm]<br />

1.7 IN-LBS [0.19 Nm]<br />

1.7 1.7 1.7 IN-LBS [0.19 [0.19 Nm] Nm]<br />

.54in<br />

[13.72mm] .54in<br />

[13.72mm]<br />

.54in .54in<br />

[13.72mm]<br />

2.18 in<br />

[55.37mm] 2.18 in<br />

[55.37mm]<br />

2.18 2.18 in in in<br />

[55.37mm]<br />

.19-.23 IN [5-6mm]<br />

.19-.23 IN [5-6mm]<br />

.19-.23 IN IN IN [5-6mm]<br />

9-28<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

11<br />

11<br />

11 11 11


Power SEM3T | Selection Distribution and Application Guide Solutions<br />

SEM3T | Selection and Application Guide<br />

SEM3T<br />

Revised on 10/15/20<br />

Ordering and technical data<br />

SEM3T Thermal Sensors<br />

.06in .06in [1.52mm] Overall Overall Thickness<br />

.45in<br />

.45in [11.43mm]<br />

[11.43mm]<br />

Diameter “A” “A” Diameter “B” “B”<br />

10ft 10ft [3.66m] [3.66m]<br />

+<br />

+<br />

.60in<br />

.60in [15.24mm]<br />

[15.24mm]<br />

2.29in<br />

2.29in [58.17mm]<br />

[58.17mm] 3.29in<br />

3.29in [83.57mm]<br />

[83.57mm]<br />

Screw Ring Terminal<br />

Dimensions inches [mm]<br />

Description Catalog Number A B<br />

SEM3T sensor<br />

1⁄ 4” terminal<br />

SEM3T sensor<br />

5⁄ 16” terminal<br />

SEM3T sensor<br />

3⁄ 8” terminal<br />

SEM3T sensor<br />

1⁄ 2” terminal<br />

7KT1281-2SA00<br />

7KT1281-2SA01<br />

7KT1281-2SA02<br />

7KT1281-2SA03<br />

0.257<br />

[6.527]<br />

0.323<br />

[8.204]<br />

0.386<br />

[9.804]<br />

0.515<br />

[13.081]<br />

0.625<br />

[15.875]<br />

1.00<br />

[25.4]<br />

1.125<br />

[28.575]<br />

1.25<br />

[31.75]<br />

* Example: The SEM3T Sensor 1/4” terminal accepts a 1/4” bolt /screw and the<br />

tightening torque is 6-9 lb-ft.<br />

Torque (lb-ft) for<br />

non-lubricated<br />

threads*<br />

6 – 9<br />

6 – 9<br />

20 – 30<br />

40 – 50<br />

Cylindrical Ring Terminal<br />

.52in<br />

.52in [13.21mm]<br />

[13.21mm]<br />

.34in<br />

.34in [8.64mm]<br />

[8.64mm]<br />

.43in<br />

.43in [10.92mm]<br />

[10.92mm]<br />

.73in<br />

.73in [18.54mm]<br />

[18.54mm]<br />

2.32in<br />

2.32in [58.93mm]<br />

[58.93mm]<br />

Description<br />

SEM3T sensor cylindrical<br />

Sensor Information<br />

Catalog Number<br />

7KT1281-2CA00<br />

Description<br />

Information<br />

Altitude / Elevation<br />

3000 Meters/9843 Feet<br />

Pollution Degree 3 (UL 61010)<br />

Overvoltage Category IV (UL 61010)<br />

Operating Temperature Range 0°C to 130°C / 32°F to 266°F<br />

Wire Type<br />

UL rated operating temperature to 200ºC,<br />

600V rated, UL style 1199, 18 AWG, 10x30<br />

stranded<br />

9 POWER<br />

MONITORING<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 9-29<br />

12


Power Distribution Solutions<br />

SEM3T<br />

Revised on 10/15/20<br />

Selection and Application Guide | SEM3T<br />

Ordering and technical data<br />

Racks and Cables<br />

Variable Dimensions inches [mm]<br />

Catalog Number Description A B C D<br />

US2:SEM3RACK3 3 position rack 1.90 [48.26] 3.57 [90.68] 2.28 [57.91] 1.79 [45.46]<br />

US2:SEM3RACK6 6 position rack 3.67 [93.22] 5.34 [135.64] 4.05 [102.87] 1.79 [45.46]<br />

US2:SEM3RACK9 9 position rack 5.44 [138.18] 7.07 [179.58] 5.82 [147.83] 1.59 [40.38]<br />

US2:SEM3RACK15 15 position rack 8.98 [228.09] 10.61 [269.49] 9.36 [237.74] 1.59 [40.38]<br />

US2:SEM3RACK21 21 position rack 12.52 [318.01] 14.15 [359.41] 12.90 [327.66] 1.59 [40.38]<br />

D<br />

6” (152.40 mm)<br />

US2:SEM3CAB6INCH<br />

12” (304.80 mm)<br />

US2:SEM3CAB12INCH<br />

24” (609.60 mm)<br />

US2:SEM3CAB24INCH<br />

9<br />

600V Rated<br />

36” (914.40 mm)<br />

US2:SEM3CAB36INCH<br />

POWER<br />

MONITORING<br />

Product Connector Electrical Ratings<br />

Description<br />

Controller Rack Connector<br />

Sensor<br />

Module<br />

Rack - Ethernet Connector<br />

Rack - Module Connector<br />

Information<br />

12VDC, 0.5A max<br />

5VDC, 0.14mA max<br />

12VDC, 12mA max<br />

12VDC, 0.5A max<br />

12VDC, 12mA max<br />

IP20<br />

0 ... 80% up to 31º C<br />

0 ... 50% at 40º C<br />

14º...149ºF<br />

-10º...65ºC<br />

13<br />

9-30<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Distribution Solutions<br />

SEM3T<br />

Revised on 11/30/20<br />

Ordering information<br />

Order Information<br />

Controller<br />

Catalog Number<br />

SEM3T Controller with Wi-Fi<br />

7KT1281-0AA10<br />

SEM3T Controller wiithout Wi-Fi<br />

Thermal Sensor Module<br />

7KT1281-0AA00<br />

with Wi-Fi<br />

without Wi-Fi<br />

SEM3T Sensor Module<br />

7KT1281-1AA00<br />

Thermal Sensors<br />

SEM3T Sensor Screw Ring Terminal 1 ⁄ 4”<br />

7KT1281-2SA00<br />

SEM3T Sensor Screw Ring Terminal 5 ⁄ 16”<br />

7KT1281-2SA01<br />

SEM3T Sensor Screw Ring Terminal 3 ⁄ 8”<br />

SEM3T Sensor Screw Ring Terminal 1 ⁄ 2”<br />

7KT1281-2SA02<br />

7KT1281-2SA03<br />

SEM3T Sensor Cylindrical Ring Terminal<br />

7KT1281-2CA00<br />

Accessories<br />

SEM3T Wi-Fi Antenna and Cable<br />

7KT1281-8AN00<br />

Meter Racks<br />

Module Rack 3 Position<br />

Module Rack 6 Position<br />

Module Rack 9 Position<br />

Module Rack 15 Position<br />

Module Rack 21 Position<br />

Cables<br />

Controller to Rack Cable – 6 inch<br />

Controller to Rack Cable – 12 inch<br />

Controller to Rack Cable – 24 inch<br />

Controller to Rack Cable – 36 inch<br />

Controller to Rack Cable – 5 Foot<br />

Controller to Rack Cable – 10 Foot<br />

Controller to Rack Cable – 20 Foot<br />

Standard Enclosures for retrofit and external wall mount applications<br />

SEM3T 21 x Thermal Points ENCLOSURE NEMA Type 1 – SEM3T Controller,<br />

Thermal Modules, Racks, Cables, 24VDC PS, Fusing, and Wiring<br />

SEM3T 21 x Thermal Points ENCLOSURE NEMA Type 12 – SEM3T Controller,<br />

Thermal Modules, Racks, Cables, 24VDC PS, Fusing, and Wiring<br />

SEM3T 21 x Thermal Points ENCLOSURE NEMA Type 4 – SEM3T Controller,<br />

Thermal Modules, Racks, Cables, 24VDC PS, Fusing, and Wiring<br />

SEM3T 45 x Thermal Points ENCLOSURE NEMA Type 1 – SEM3T Controller,<br />

Thermal Modules, Racks, Cables, 24VDC PS, Fusing, and Wiring<br />

SEM3T 45 x Thermal Points ENCLOSURE NEMA Type 12 – SEM3T Controller,<br />

Thermal Modules, Racks, Cables, 24VDC PS, Fusing, and Wiring<br />

SEM3T 45 x Thermal Points ENCLOSURE NEMA Type 4 – SEM3T Controller,<br />

Thermal Modules, Racks, Cables, 24VDC PS, Fusing, and Wiring<br />

Standard Enclosures for retrofit and external wall mount applications<br />

SEM3T Controller 24VDC Power Supply<br />

(Only sold with loose SEM3T Controller)<br />

US2:SEM3RACK3<br />

US2:SEM3RACK6<br />

US2:SEM3RACK9<br />

US2:SEM3RACK15<br />

US2:SEM3RACK21<br />

US2:SEM3CAB6INCH<br />

US2:SEM3CAB12INCH<br />

US2:SEM3CAB24INCH<br />

US2:SEM3CAB36INCH<br />

US2:SEM3CAB5FT<br />

US2:SEM3CAB10FT<br />

US2:SEM3CAB20FT<br />

US2:SEM3T21ENCLN1<br />

US2:SEM3T21ENCLN12<br />

US2:SEM3T21ENCLN4<br />

US2:SEM3T45ENCLN1<br />

US2:SEM3T45ENCLN12<br />

US2:SEM3T45ENCLN4<br />

US2:SEM3T24VDCPS<br />

9 POWER<br />

MONITORING<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 9-31


SEM3T<br />

Power<br />

| Selection<br />

Distribution<br />

and Application Guide<br />

Solutions<br />

SEM3T<br />

SEM3T System Configuration in Switchgear<br />

SEM3T System Configuration in Switchboards<br />

Typical SEM3T Thermal Sensor locations in Low Voltage Switchgear.<br />

Typical SEM3T Thermal Sensor locations in Low Voltage Switchgear.<br />

Revised on 10/15/20<br />

Typical configuration<br />

Fig 1: Rear View of Switchgear<br />

SEM3T Sensor on<br />

Power Connector*<br />

SEM3T Sensor on<br />

Power Connector*<br />

Section 1 Section 2<br />

SEM3T Sensor is typically installed at two locations<br />

on LVS as shown in Fig 1 & 2:<br />

*Power Connector (Where Horizontal Bus connects<br />

to Vertical Bus)<br />

Lug Pads (Incoming & Load)<br />

The sensor is installed either under bolt head or<br />

nut as applicable, one sensor per phase.<br />

SEM3T Sensor on Lug Pads.<br />

POWER<br />

MONITORING<br />

9<br />

Mounted over the Lug<br />

Fig 2: Rear Iso View of Switchgear<br />

14<br />

9-32<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Distribution Solutions<br />

SEM3T<br />

SEM3T System Configuration in Switchboards<br />

SEM3T System Configuration in Switchboards<br />

Typical SEM3T Thermal Sensor locations in Low Voltage Switchboards<br />

Typical SEM3T Thermal Sensor locations in Low Voltage Switchgear.<br />

Revised on 10/15/20<br />

Selection and Application Guide | SEM3T<br />

Typical configuration<br />

SEM3T Sensor is typically installed at following locations on Switchboard<br />

as shown in Fig 3 & 4:<br />

Splice<br />

Lug Pads (Incoming & Load)<br />

The sensor is installed either under bolt head or nut as applicable, one<br />

sensor per phase.<br />

SEM3T sensor on<br />

splice connection<br />

Fig 4: Front Iso view<br />

of Switchboard<br />

Fig 3: Front view<br />

of Switchboard<br />

SEM3T Sensor on Lug Pads, mounted over the lug<br />

SEM3T Sensor C-Ring is installed on cable insulation for outgoing MCCB<br />

breakers. The sensor is installed with a cable zip tie.<br />

One sensor per phase.<br />

SEM3T Sensor C-Ring is installed on the cable insulation of P4, P5 Panels<br />

as shown in Fig 5:<br />

The sensor is installed with a cable zip tie, one sensor per phase.<br />

9 POWER<br />

MONITORING<br />

Fig 5: Front View of Panel<br />

15<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 9-33


Power Distribution Solutions<br />

Revised on 10/15/20<br />

Powermanager<br />

A power management system that can be customized to your needs.<br />

View and control your facilities’ infrastructure condition from anywhere.<br />

Cost allocation and Sub-billing Reports<br />

Cost allocation and sub-billing functionality in the Powermanager<br />

software allows the user to track energy related costs by building,<br />

floor, tenant, feeder or location. Match virtually any fixed rate<br />

billing structure and use comprehensive multi-year scheduling and<br />

time-of-use features to manage the energy costs.<br />

Load Studies and Asset Management<br />

Trend power usage data to take full advantage of your electrical<br />

distribution system capacity and avoid over-design. Create usage<br />

profiles that will allow you to distribute loads and avoid demand<br />

peak which helps to identify energy leaks such as equipment<br />

running during down time.<br />

Equipment Monitoring and Control<br />

Powermanager allows you to meter all your utilities including gas,<br />

steam, air and water and set up general condition alarming and<br />

pre-event alarms for impending or imminent conditions. Interface<br />

with other energy management and SCADA systems through<br />

multiple communication channels and protocols like OPC.<br />

Reports<br />

Standard reports provide models of daily electricity usage so you<br />

can distribute loads and avoid demand peaks. This enables you<br />

to allocate energy consumption and/or costs to individual areas<br />

and identify expensive processes that need attention. The historic<br />

trending report compiles data from load circuits over a users<br />

predefined period. This enables the user to fully utilize the power<br />

distribution system and run at near rated tolerances.<br />

Ordering information<br />

SENTRON Powermanager software,<br />

combined with Siemens power meters and<br />

low-voltage protective devices, provides a<br />

complete energy management solution for<br />

your business. It allows you to measure,<br />

process, analyze, store and share energy<br />

usage and status information across your<br />

entire enterprise. It offers control capabilities,<br />

comprehensive energy usage and reliability,<br />

and detailed reporting that will help you<br />

reduce energy related costs.<br />

Benefits<br />

n Visibility and control of power flows<br />

n Exact knowledge of the consumption profile<br />

n Increase of energy efficiency<br />

n Optimization of power supply contracts<br />

n Compliance with contractual terms or regulations<br />

n Allocation of costs to individual cost centers<br />

n Optimization of plant maintenance<br />

n Identification of critical systems conditions<br />

The Powermanager software:<br />

n Is available in a stand-alone or LAN/WAN based configuration<br />

that can also exchange information with other supervisory<br />

systems like building automation software<br />

n Can utilize any Ethernet or serial based connections<br />

n Is expandable from the basic monitoring application to a fully<br />

customized enterprise management system<br />

n Is fully scalable with regard to the connected devices and to<br />

the software’s function to meet current and future needs<br />

n Ensures the seamless integration of power monitoring devices<br />

from the Siemens SENTRON PAC Series Meter, SEM3,<br />

and SENTRON WL/VL/3VA circuit breakers as well as other<br />

Modbus communicating devices<br />

n Is designed to collect, archive, monitor, display and evaluate<br />

any kind of energy related device data<br />

n Provides web based reporting and detailed graphics<br />

construction utilities as standard<br />

9<br />

POWER<br />

MONITORING<br />

Powermanager Software V4.x and greater versions - Device Licenses<br />

POWERMANAGER BASIC 10 DEVICES<br />

POWERMANAGER 20 ADTNL.DEVICES<br />

POWERMANAGER 50 ADTNL.DEVICES<br />

POWERMANAGER 100 ADTNL.DEVICES<br />

POWERMANAGER 200 ADTNL.DEVICES<br />

POWERMANAGER 500 ADTNL.DEVICES<br />

POWERMANAGER 1000 ADTNL.DEVICES<br />

Powermanager Software V4.x and greater versions - Add Ons and Upgrades<br />

POWERMANAGER OPT PACKAGE EXPERT<br />

POWERMANAGER OPT PACKAGE CLIENT (2)<br />

POWERMANAGER OPT PACKAGE CLIENT (5)<br />

POWERMANAGER OPT PACKAGE 1 x DISTR SYS<br />

Contact Siemens for upgrade information<br />

Catalog Number<br />

7KN27102CE400YC0<br />

7KN27111CE400YC0<br />

7KN27112CE400YC0<br />

7KN27113CE400YC0<br />

7KN27114CE400YC0<br />

7KN27115CE400YC0<br />

7KN27116CE400YC0<br />

Catalog Number<br />

7KN27120CE400YC0<br />

7KN27121CE400YC0<br />

7KN27122CE400YC0<br />

7KN27124CE400YC0<br />

9-34<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Distribution Solutions<br />

Revised on 03/31/20<br />

WinPM.Net Enhanced Web-Enabled Energy Management Software<br />

Cost allocation and sub-billing<br />

Track energy-related costs by building,<br />

feeder, or tool. Match virtually any<br />

billing structure and use comprehensive<br />

multi-year scheduling and time-of-use<br />

activity profiles.<br />

Load studies and asset management<br />

Trend power usage data to take full<br />

advantage of your electrical distribution<br />

system capacity and avoid over-design.<br />

Create usage profiles so you can<br />

distribute loads and avoid demand<br />

peak.<br />

Demand and power factor control<br />

Eliminate penalties through automated<br />

power factor correction, load shedding,<br />

or peak shaving.<br />

Equipment monitoring and control<br />

Meter all your utilities including<br />

gas, steam, air and water. Set up<br />

alarms for pending problems, prealarm<br />

on impending or imminent<br />

conditions. Interface with other energy<br />

management and SCADA systems<br />

through multiple communication<br />

channels and protocols.<br />

WinPM.Net is a complete energy information management solution for<br />

your business allowing you to process, analyze, store and share energy<br />

usage and power quality data across your entire enterprise. It offers<br />

control capabilities, comprehensive power quality and reliability analysis<br />

and can help you reduce energy-related costs. WinPM.net allows you to<br />

manage intelligent metering and protective devices, analyze data, and<br />

decide on new courses of action to help you save money and keep your<br />

business up and running.<br />

Its cutting-edge flexibility and compatibility means you can add one<br />

piece at a time, at your own pace, while still maintaining your original<br />

investments. Interface to your existing systems through industry-standard<br />

protocols and choose newer components as they become available.<br />

The WinPM.Net software:<br />

n Provides detailed analysis of the power quality and overlays waveforms<br />

to correlate phase-to-phase relationships between voltages and<br />

currents and cascading failures<br />

n Pinpoints the sources of transients, harmonics, or sags, whether<br />

external or internal to your facility, allowing you to decide on the right<br />

corrective actions. By monitoring circuits 24 hours a day, you can<br />

develop strategies to avoid interruptions<br />

n Provides a comprehensive graphics utility as standard to build and edit<br />

any graphical screen whether it is a standard screen or a customized<br />

one. These custom screens can display real-time and historical data,<br />

alarms, status indications, meter, relay and third party equipment<br />

information<br />

n Supports Modbus RTU, Modbus TCP, ION, XML, OPC, FTP, and PQDIF<br />

compliant systems, so you can unify your diverse operations into one<br />

system. Interface to other energy management software, or include<br />

transducers, PLCs, and RTUs in a WinPM.net network. OPC can extract<br />

values from other software databases then combine these values with<br />

up-to-date readings from WinPM.net to perform real time calculations<br />

n Offers easy, cost effective and fast system expansion. The system<br />

grows as your needs grow. Add one piece at a time, at your own pace,<br />

within your own budget<br />

Ordering information<br />

Software<br />

WinPM.NET V9.0 DVD New (Includes 5 meter device licenses,<br />

1 Eng Client, 2 Web Clients, New! Dashboards & PQDIF)<br />

WinPM.NET V9.0 DVD Replacement<br />

Device License<br />

WinPM.Net V9.0 9xxx Meter Device License Limit 6 to 50<br />

WinPM.Net V9.0 9xxx Meter Device License Limit 51 to 100<br />

WinPM.Net V9.0 9xxx Meter Device License Limit 101 to 1000<br />

WinPM.Net V9.0 3rd Party device/Modbus/SeaBus Dev. Lic. Limit 1 to 50<br />

WinPM.Net V9.0 3rd Party device/Modbus/SeaBus Dev. Lic. Limit 51 to 100<br />

WinPM.Net V9.0 3rd Party device/Modbus/SeaBus Dev. Lic. Limit 101 to 1000<br />

Options<br />

WinPM.Net V9.0 Engineering Client License Limit 2 to 50<br />

WinPM.Net V9.0 Engineering Client License Limit 51 to 100<br />

WinPM.Net V9.0 Web Client License<br />

WinPM.Net V9.0 OPC Server License<br />

WinPM.NetSQL Server <strong>2017</strong> - 2 CORE License increment (*** Minimum<br />

of 4 cores per server is required (2 x 3ZS67317CC900BA0 minimum))<br />

Software upgrade<br />

Catalog Number<br />

3ZS67100CC900BA0<br />

3ZS67100CC900BC0<br />

3ZS68120CC900BA2<br />

3ZS68130CC900BA2<br />

3ZS68140CC900BA2<br />

3ZS68220CC900BA2<br />

3ZS68230CC900BA2<br />

3ZS68240CC900BA2<br />

3ZS67220CC900BA2<br />

3ZS67230CC900BA2<br />

3ZS67420CC900BA2<br />

3ZS67520CC900BA2<br />

3ZS67317CC900BA0<br />

Contact your local SIEMENS D&CES Business Developer for ordering information & upgrade.<br />

Allows remote configuration of base WinPM.Net software. Excel is required for excel base reports using<br />

Reporter. Outlook is required for e-mailing reports.<br />

9 POWER<br />

MONITORING<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 9-35


Power Distribution Solutions<br />

Revised on 04/30/19<br />

Digitalization for Smart Infrastructure<br />

Cloud & IIoT Solution Offerings<br />

The Siemens Digital Solutions & Services team offers a<br />

complete portfolio of digitally enabled products that provide<br />

access to data for customers to manage and monitor their<br />

assets, as well as analytical insights into their electrical<br />

infrastructure.<br />

Provides:<br />

• Edge Connectivity for Cloud Applications<br />

• Plug & Play for Siemens LP Products<br />

• Simplified Dashboarding of Connected Assets<br />

• Mobile, Tablet, & Desktop Compatible<br />

• Multiple Data Export Options<br />

• MindSphere Enabled<br />

Edge Data Collection Unit (DCU)<br />

n Collects field-level device data and stores locally at the edge<br />

n Predefined asset model for automatic configuration of<br />

MindSphere assets<br />

n Custom Dashboarding of live data<br />

n Dual Ethernet ports for local and external networks<br />

n Easily connect and monitor standard modbus devices<br />

n Standard device drivers for LP equipment::<br />

• PAC Power Meters<br />

• ACCESS Power Meters<br />

• SEM3<br />

• 3WL, 3VA, 3VL<br />

n Energy usage and cost breakdown for sub-billing<br />

n One-time or scheduled data export via FTP, USB, and Email<br />

n On-board storage options with or without local display<br />

SIMATIC Nanobox<br />

PC IPC127E<br />

SIMATIC Nanobox<br />

PC IPC227E<br />

SIMATIC Touch PC<br />

IPC277E (7”)<br />

9<br />

POWER<br />

MONITORING<br />

Cloud Connectivity and Applications<br />

Data aggregated in the Edge DCU can be pushed to an<br />

external server or cloud platform for long-term storage. The<br />

Edge DCU also offers greater flexibility in configuring and<br />

creating a hierarchy of your assets. By doing configuration at<br />

the local level and pushing this structure to cloud platforms,<br />

such as MindSphere, it removes the need of programming<br />

the traditional MindConnect devices in the cloud, transferring<br />

the configuration files to USB, before loading directly onto<br />

hardware. Cloud connectivity empowers customers to realize<br />

value from their data by giving them access to their data<br />

outside of their facility. This allows customer to interact with<br />

their data using applications built by Siemens experts, or<br />

develop new applications for specific requirements. Using the<br />

Siemens cloud applications, users have the ability to choose<br />

and change displays to the specific metrics of interest,<br />

view and compare time-series data of similar devices, and<br />

configure and export reports.<br />

9-36<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Power Distribution Solutions<br />

Services<br />

Advantages to You...<br />

n Technical experts<br />

n Single source supplier<br />

n Available 24/7,<br />

365 days a year<br />

n Reduced total cost of<br />

ownership (TCO)<br />

n Avoid unscheduled<br />

downtime with<br />

preventive maintenance<br />

Service Products<br />

Modular service products enable<br />

you to customize a technical service<br />

agreement to meet your organization’s<br />

maintenance needs over the entire<br />

life cycle of your installation. Including<br />

Service products in your TSA will<br />

provide the following benefits:<br />

• Substantial savings versus “on<br />

demand” purchases<br />

• Optimized scaling of your<br />

maintenance organization<br />

• Assurance that your installation is<br />

operating at maximum performance<br />

and availability<br />

Telephone and Internet<br />

Priority support<br />

When you need help right now, choose<br />

the support coverage that fits your<br />

business:<br />

24 hours x 7 days a week<br />

8 hours x 5 days a week<br />

Extended support<br />

With extended support, you can<br />

request blocks of support hours for<br />

specific projects and tasks. We can<br />

customize this support service to meet<br />

your individual needs.<br />

Remote service<br />

Remote service provides support and<br />

diagnostics via data line to save you<br />

time and money. Technical support<br />

specialists directly access your system<br />

for real-time troubleshooting to provide<br />

maximum uptime.<br />

Technical account liaison<br />

A technical account liaison provides<br />

consulting and guidance on all aspects<br />

of support through familiarity with the<br />

application, your business goals and<br />

processes, and your maintenance and<br />

engineering staff.<br />

In addition to a site visit to assess your<br />

installation and support requirements,<br />

the technical account liaison will<br />

conduct monthly reviews with your<br />

staff to ensure you are receiving<br />

maximum payback on your investment.<br />

Field services<br />

Block of hours<br />

Purchase field service hours in 40 hour<br />

increments for preventative, predictive<br />

or emergency services.<br />

Maintenance programs<br />

Packaged maintenance programs<br />

available for:<br />

• System performance checks<br />

• Run diagnostics<br />

• Analyze power quality<br />

• Visual inspections of key system<br />

components<br />

• Database trim and backup<br />

Training<br />

Operation and maintenance<br />

Siemens training offers a broad range of<br />

educational services, providing quality<br />

and excellence to the automation<br />

industry. Targeted product and system<br />

training provides the student with<br />

practical, hands-on experience.<br />

Customized on-site training<br />

On-site training is excellent for large<br />

groups or when individual, one-on-one<br />

instruction is needed. When the trainer<br />

visits your facility, product training<br />

will be conducted on your specific<br />

installation. Classroom lectures, and<br />

trouble-shooting techniques specific to<br />

your installation are covered in detail<br />

during the training session.<br />

Software update service<br />

The software update service<br />

enables you to take advantage of<br />

enhancements to the most current<br />

software versions. A site evaluation<br />

is conducted to determine necessary<br />

upgrade requirements prior to the<br />

Software Update Service.<br />

9 POWER<br />

MONITORING<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 9-37


Power Distribution Solutions<br />

Notes<br />

POWER<br />

MONITORING<br />

9<br />

9-38<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Surge Protective Devices (SPD)<br />

SPEEDFAX TM<br />

Section<br />

c o n t e n t s<br />

Scan to connect<br />

online to the<br />

most up-todate<br />

version of<br />

this Section of<br />

SPEEDFAX.<br />

Siemens TPS3 family of hardwired Surge Protective Devices<br />

(formally known as Surge/Lightning Arrestors and/or<br />

Transient Voltage Surge Suppressors –TVSS)<br />

Family SPDs 10-2<br />

SOLID Protection 10-3<br />

BoltShield Surge Protective Devices 10-4 – 10-5<br />

First Surge 10-6 – 10-7<br />

TPS3 01 and TPS3 L1 (10 Mode) 10-8<br />

TPS3 02 and TPS3 L2 (10 Mode) 10-9<br />

TPS3 03 10-10<br />

TPS3 03 DC 10-11<br />

TPS3 05 and TPS3 L5 (10 Mode) 10-12<br />

TPS3 06 and TPS3 L6 (10 Mode) 10-13<br />

TPS3 09 10-14<br />

TPS3 11 10-15<br />

TPS3 12 and TPS3 L12 (10 mode) 10-16<br />

TPS3 15 and TPS3 L15 (10 mode) 10-17<br />

Frequently Asked Questions 10-18<br />

Integrally Mounted SPDs External or Wall Mounted SPDs Residential SPDs<br />

See pages 1-50 – 1-52<br />

Features<br />

Features<br />

Features<br />

n Per Phase Surge Current Capacity<br />

ranging from 100 kA to 1000 kA<br />

n Industry best VPRs<br />

n Per Phase Surge Current Capacity<br />

ranging from 50 kA to 1000 kA<br />

n Industry best VPRs<br />

n Per Phase Surge Current Capacity<br />

of 40, 50, 60, 100 or 140 kA<br />

n Complete Service Protection for<br />

n I n = 20 kA (most models)<br />

n Across the board UL 96A compliance<br />

(most models)<br />

n Ground Reference Monitoring<br />

(GRM) diagnostics<br />

n I n = 20 kA (most models)<br />

n Across the board UL 96A compliance<br />

(most models)<br />

n Ground Reference Monitoring<br />

(GRM) diagnostics<br />

(excluding TPS3 03 & TPS3 09)<br />

- Power<br />

- Telephone<br />

- Coax<br />

n Ground Reference Monitoring<br />

(GRM) diagnostics<br />

10 SPD<br />

(Section was last modified on 07/24/20)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 10-1


SPD - Surge Protective Devices<br />

Revised on 03/31/20<br />

Siemens Surge Protection Innovations<br />

Introduction<br />

In today’s electronic world, home and<br />

business electrical systems just aren’t<br />

complete unless they incorporate surge<br />

protection. Stopping Surges Before<br />

They Get Into these systems is best<br />

accomplished through the installation<br />

of appropriately sized hard-wired surge<br />

protective devices (SPDs) beginning at the<br />

incoming service followed by installations<br />

at other key surge entry points.<br />

When Siemens first developed the<br />

Transient Protection System (TPS) family<br />

of surge protectors, we knew early<br />

on that hard-wired surge protectors<br />

needed fully coordinated safety controls.<br />

This led to the adoption of a number<br />

of SPD industry safety control firsts<br />

including the patented Ceramgard and<br />

TranSafe circuitry, coordinated fusing<br />

and thermal cutouts, dielectric isolation,<br />

mechanical re-enforcing taping, etc…<br />

resulting in a design that ensures the<br />

highest possible electrical system surge<br />

protection and reliability.<br />

Our next generation UL 1449 4th Edition<br />

TPS3 SPDs carry on this same legacy.<br />

Every TPS3 is infused with Siemens<br />

engineering safety and performance<br />

“know-how.” Siemens SPDs have the<br />

highest degree of safety while delivering<br />

the industry’s best performance<br />

ratings – some of the lowest Voltage<br />

Protection Ratings (VPRs), Type 1 or 2<br />

and 20 kA I-nominal ratings (for most<br />

models) with surge current ratings<br />

from 50 to 1000 kA.<br />

The BoltShield line of SPDs helps<br />

address the changing NEC codes that<br />

require surge protection in all dwellings.<br />

The Siemens BoltShield family of<br />

residential and commercial products<br />

allows this to be done easily and at a<br />

reasonable cost.<br />

Electrical disturbances will always<br />

occur, but they don’t have to cause<br />

surge protectors to fail in an unsafe<br />

manner. Safer surge protection means<br />

uncompromised electrical system<br />

protection, safety, and reliability.<br />

The following pages provide additional<br />

technical and ordering information<br />

concerning our entire offering of surge<br />

protection devices.<br />

Surge Protector Per Phase Surge Current Capacities<br />

Wall Mounted Standard Mode<br />

Per Phase<br />

Surge<br />

Current<br />

TPS3 01 TPS3 02 TPS3 03 TPS3 03 DC TPS3 05 TPS3 06 TPS3 09 TPS3 11 TPS3 12 TPS3 15<br />

50 kA<br />

100 kA<br />

150 kA<br />

200 kA<br />

250 kA<br />

300 kA<br />

400 kA<br />

500 kA<br />

600 kA<br />

800 kA<br />

1000 kA<br />

10 Mode SPDs<br />

Per Phase<br />

Surge<br />

Current<br />

TSP3 L1 TPS3 L2 TPS3 L5 TPS3 L6 TPS3L 12 TPS3L 15<br />

10<br />

SPD<br />

100 kA<br />

150 kA<br />

300 kA<br />

450 kA<br />

500 kA<br />

600 kA<br />

900 kA<br />

10-2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


SPD - Surge Protective Devices<br />

Recommending Surge Protection<br />

SOLID Protection<br />

Either at home or in the work place,<br />

nearly every electrical load is electronic<br />

infused. With today’s power quality<br />

being the same as it was 50 years ago,<br />

equipment is more susceptible to surge<br />

damage and/or disruption generated<br />

by normal electrical distribution<br />

interactions. Places where lightning<br />

activity is minimal are now experiencing<br />

more electronic failures due to surges<br />

generated by the day to day operations<br />

of equipment like washers and dryers,<br />

copiers, chillers, etc.<br />

In response to this susceptibility, code<br />

authorities have mandated emergency<br />

power distribution equipment now<br />

must be protected by a listed SPD.<br />

The reasoning is based upon anecdotal<br />

understating that surge protected<br />

systems are more reliable. Supported by<br />

S O L D<br />

government studies, the most efficient<br />

way to protect electrical systems from<br />

surges is through the installation of<br />

hardwired SPDs at key points throughout<br />

the distribution system. These locations<br />

can easily be remembered by memorizing<br />

the locations of the acrostic found within<br />

the following phrase, “The best surge<br />

protected system is a SOLID one,” where<br />

each letter of the word SOLID stand for<br />

the locations on the electrical system<br />

where SPDs should be installed.<br />

The illustration to the right shows<br />

“SOLID” locations for a school’s electrical<br />

system. Under each ‘SOLID’ location is a<br />

Siemens TPS3 model number with surge<br />

current capacities matching those to what<br />

are typically specified by consultants<br />

across North America.<br />

TPS30620<br />

or<br />

TPS31220<br />

TPS30515<br />

or<br />

TPS31215<br />

TPS30110<br />

or<br />

TPS31110<br />

TPS31110<br />

or<br />

TPS30910<br />

TPS30350<br />

or<br />

Call TPS Group<br />

Service<br />

Entrance<br />

Outside loads<br />

like Parking<br />

Lot Lighting<br />

powered<br />

from<br />

distribution<br />

panels<br />

Lower voltage<br />

distribution<br />

panels<br />

powering<br />

computers<br />

and other<br />

electronics<br />

Individual<br />

critical<br />

equipment<br />

like servers<br />

Data,<br />

telephone,<br />

and coaxial<br />

cables<br />

Surge Arrestor Replacement<br />

Discrete or True 10 Mode Style SPDs<br />

TPS3 03<br />

Type 1 SPD<br />

with I n = 20 kA<br />

Low-voltage surge and lightning<br />

arrestors became obsolete when<br />

UL 1449 3rd edition went into<br />

effect in 2009.<br />

They were replaced with Type<br />

1 SPDs having an I-nominal (I n )<br />

rating equal to 20 kA. Most all<br />

Siemens TPS3s are rated as<br />

Type 1, I n =20 kA SPDs. However,<br />

the style and form factor of traditional<br />

surge arrestors is best<br />

replaced using our TPS3 03.<br />

A B C N G<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

= Parallel MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

For mission critical or high profile applications,<br />

a growing number of end users prefer the assurance<br />

discrete or true 10-mode SPDs provide.<br />

When surges traverse the electrical system<br />

via phase to phase conductors, standard SPDs<br />

indirectly protect via the line to neutral or line to<br />

ground modes of protection. Siemens integral<br />

or wall mounted “Discrete” or “True” 10-mode<br />

SPDs address L-L surges by incorporating<br />

directly connected line to line surge protection<br />

elements. This style of SPD provides the “Just<br />

in Case” assurance mission critical or high profile<br />

projects require.<br />

10 SPD<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 10-3


BoltShield Surge Protective Devices<br />

BSPD – Commercial Surge Protection for Panel Boards<br />

Revised on 03/31/20<br />

Catalog Logic<br />

BSPD series for panelboards<br />

Ordering Information<br />

Catalog # BSPD – 2 – A – 100<br />

Series<br />

BSPD<br />

Poles<br />

2 = 2 Pole<br />

3 = 3 Pole<br />

Voltage Code<br />

A = 120/240V, 1Ø 3W (Fig.1) <br />

B = 240/120V, 3Ø 4W (Fig.3)<br />

C = 208Y/120V, 3Ø 4W (Fig.2)<br />

D = 240V, 3Ø 3W (Fig.4)<br />

E = 480Y/277V, 3Ø, 4W (Fig.1)<br />

F = 480V, 3Ø, 3W (Fig.4)<br />

G = 600V, 3Ø, 3W (Fig.4)<br />

K = 380Y/220V, 3Ø, 4W (Fig.1)<br />

L = 600Y/347V, 3Ø, 4W (Fig.1)<br />

S = 400Y/230V, 3Ø, 4W (Fig.1)<br />

T = 415Y/240V, 3Ø, 4W (Fig.1)<br />

Surge Current Rating<br />

100 = 100kA per Mode/Phase<br />

BSPD Series<br />

Product specifications<br />

General specifications<br />

Maximum surge current rating range<br />

UL Type designation<br />

UL 1449 I-nominal rating<br />

UL 1449 short circuit current rating<br />

Repetitive impulse<br />

Response time<br />

100 kA per phase<br />

SPD Type 1 b<br />

20kA<br />

200kA<br />

5,000 hits<br />


BoltShield Surge Protective Devices<br />

QSPD – Residential Surge Protection for Load Centers<br />

Revised on 07/31/20<br />

Catalog Logic<br />

QSPD series for load centers<br />

Ordering Information<br />

QSPD catalog number logic<br />

QSPD – 2 – A – 065<br />

Series<br />

QSPD<br />

Poles<br />

2 = 2 Pole<br />

3 = 3 Pole<br />

Voltage Code<br />

A = 120/240V, 1Ø 3W (Fig.1) <br />

B = 240/120V, 3Ø 4W (Fig.3)<br />

C = 208Y/120V, 3Ø 4W (Fig.2)<br />

D = 240V, 3Ø 3W (Fig.4)<br />

Surge Current Rating<br />

065P = 65kA per Mode/Phase<br />

in retail blister pack packaging<br />

QSPD-Base catalog number logic<br />

QSPD – 2 – A – 035B<br />

Series<br />

QSPD<br />

Poles<br />

2 = 2 Pole<br />

Voltage Code<br />

A = 120/240V, 1Ø 3W (Fig.1) <br />

Surge Current Rating<br />

035B = 35kA per Mode/Phase<br />

QSPD Series<br />

QSPD-Base<br />

Product specifications<br />

General specifications QSPD QSPD-Base<br />

Maximum surge<br />

current rating range<br />

65kA per phase 35kA per phase<br />

UL Type designation<br />

SPD Type 1 b<br />

UL 1449 I-nominal rating<br />

UL 1449 short circuit<br />

current rating<br />

Repetitive impulse<br />

Response time<br />

20kA<br />

200kA<br />

5,000 hits<br />


SPD - Surge Protective Devices<br />

FirstSurge<br />

FirstSurge Total Home Surge Protection<br />

Total Home Protection<br />

Siemens believes today’s residential<br />

surge protectors come up short when<br />

protecting today’s modern home filled<br />

with smart appliances and electronics.<br />

This is why we developed our<br />

FirstSurge commercial class total<br />

home surge protectors. These electrical<br />

system surge protectors are sized for<br />

where you live. They will let you know<br />

when there is something wrong or<br />

when they are worn out.<br />

Based upon thunderstorm frequency,<br />

geographic location, and home size,<br />

we developed a surge exposure map<br />

correlating with FirstSurge current<br />

capacities known to provide years of<br />

protective service for each shaded area.<br />

Sized For Where You Live<br />

Model<br />

FirstSurge Power (FS060)<br />

FirstSurge Plus (FS100)<br />

FirstSurge Pro (FS140)<br />

Surge<br />

Capacity<br />

60,000 A<br />

100,000 A<br />

140,000 A<br />

Know You’re Protected:<br />

3 Stage Commercial Grade<br />

Notification<br />

When there is a problem, Siemens<br />

FirstSurge takes the guesswork out of<br />

knowing when it is time to be replaced.<br />

What will you see and hear when this<br />

occurs?<br />

Audible Alarm:<br />

Green LED(s):<br />

Red Service Light:<br />

Beeps<br />

Extinguish<br />

Flashes<br />

Ground Reference Monitoring (GRM)<br />

FirstSurge is GRM-equipped notifying<br />

you a rare safety hazard exists due to a<br />

compromised electrical system neutral<br />

to ground bond. What will you see and<br />

hear when this occurs?<br />

Audible Alarm: Beeps<br />

Green LED(s): Remains Lit<br />

Red Service Light: Flashes<br />

SPD<br />

10<br />

10-6<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


SPD - Surge Protective Devices<br />

FirstSurge<br />

Features & Benefits<br />

n UL 1449 Listed, Type 2, Surge Protective Device (SPD)<br />

n Rated for 120/240 split phase panels up to 400A<br />

n Surge Current Capacities:<br />

- 60,000 A<br />

- 100,000 A<br />

- 140,000 A<br />

n 3 Stage Commercial Grade Notification<br />

n Ground Reference Monitoring (GRM)<br />

n Installs onto any brand load center<br />

n Type 4 rated outdoor enclosure<br />

n 10 year product and connected equipment warranty*<br />

Technical Specifications<br />

Surge Spike Capacity<br />

Line Voltage<br />

FirstSurge Power (FS060) 60,000 A<br />

FirstSurge Plus (FS100) 100,000 A<br />

FirstSurge Pro (FS140) 140,000 A<br />

120/240 Split Phase, 50/60 Hz<br />

UL 1449 3rd Ed VPR L-N: 600 V<br />

L-G: 600 V<br />

N-G: 600 V<br />

L-L: 900 V<br />

Rated Voltage (MCOV) 150V – L-N, L-G, and N-G; 300V – L-L<br />

Response Time<br />


SPD - Surge Protective Devices<br />

TPS3 Integral or Internally Mounted SPDs<br />

Selection<br />

TPS3 01 and TPS3 L1<br />

(True or Discrete 10-Mode)<br />

Siemens TPS3 01 and L1 surge protective devices<br />

are designed for integration within our P1, P2,<br />

and P3 power distribution panel boards, as well<br />

as TIASTAR motor control centers and busway<br />

systems. The TPS3 01 and L1 SPDs feature Ground<br />

Integrity Monitoring (GIM) diagnostics<br />

10<br />

SPD<br />

TPS3 01 and TPS3 L1 Key Features<br />

n UL 1449-4 Type 2 SPD and UL 1283 Listed<br />

– Optional UL 1449 4th Edition Listed Type 1<br />

n Type 1 / Type 2 SPD<br />

n 100 - 300 kA Per Phase Surge Current<br />

n 20 kA I n (Most models)<br />

n 200 kA SCCR (Most models)<br />

n UL 96A Lightning Protection Master Labeling<br />

compliant (@ 20 kA)<br />

n Large block, individually fused, thermally<br />

protected, 50kA MOVs<br />

n Every MOV is monitored, including N-G<br />

n Mounts internal to:<br />

– P1, P2, and P3 panels<br />

– TIASTAR motor control centers –<br />

standard 6”bucket<br />

– STP series busplug on SX series busway<br />

n Consult factory for field retrofit in P1 panels<br />

n Modes of Protection: L-N, L-G, N-G, and L-L<br />

n All UL required OCP & safety coordination<br />

included<br />

– Type 1 SPDs intended for Line or Load side of<br />

Main Disconnect<br />

– Type 2 SPDs intended for Load side of<br />

Main Disconnect<br />

n Standard Monitoring: LED Indicators, Surge<br />

Counter, Dry Contacts, Audible Alarm w/ silence<br />

switch & test button<br />

n Dimensions: 11.5” x 7.2” x 4.5”<br />

(292.1 mm x 182.9 mm x 114.3 mm)<br />

n Weight: 4.55 lb. (2.06 kg)<br />

n Designed, manufactured & tested consistent with:<br />

– ANSI / IEEE C62.41.1-2002, C62.41.2-2002,<br />

C62.45-2002, C62.62-1010, C62.72-2007 and<br />

CSA C22.2 No. 269.1 and 269.2<br />

– 1992/2000 NEMA LS-1<br />

– NEC Article 285<br />

– IEC 61643, CE<br />

▪n 10 Year Product Warranty<br />

Available Options:<br />

n Direct bus connected or can be wired to a circuit<br />

breaker (include W option)<br />

Ordering Information<br />

Voltage Code<br />

A = 120/240 V, 1Ø, 3W<br />

B = 120/240 V, 3Ø, 4W<br />

C = 120/208 V, 3Ø, 4W<br />

D = 240 V, 3Ø, 3W<br />

E = 277/480 V, 3Ø, 4W<br />

F = 480 V, 3Ø, 3W<br />

G = 600 V, 3Ø, 3W <br />

K = 380/220 V, 3Ø, 4W<br />

L = 600/347 V, 3Ø, 4W<br />

S = 400/230 V, 3Ø, 4W<br />

Catalog # TPS3 01<br />

TPS3 01<br />

Surge Current (kA) Options<br />

10 = 100 kA per phase X = Surge counter<br />

15 = 150 kA per phase (Standard)<br />

20 = 200 kA per phase<br />

25 = 250 kA per phase W= Terminal lug<br />

30 = 300 kA per phase B = Busway application<br />

M = MCC application<br />

Example: TPS3C0120X002 = Type 2 SPD (Default) for a 208/120V panelboard<br />

with a surge current capacity of 200 kA per phase and a surge counter.<br />

When an option is not selected, include a zero (0) in the field.<br />

Available Accessories: Ordered Separately<br />

RMSIE = Remote monitor<br />

Available in 100 kA & 150 kA only<br />

Ordering Information<br />

Voltage Code<br />

A = 120/240 V, 1Ø, 3W<br />

B = 120/240 V, 3Ø, 4W<br />

C = 120/208 V, 3Ø, 4W<br />

E = 277/480 V, 3Ø, 4W<br />

K = 380/220 V, 3Ø, 4W<br />

S = 400/230 V, 3Ø, 4W<br />

TPS3 L1<br />

Catalog # TPS3 L1<br />

Surge Current (kA) Options<br />

15 = 150 kA per phase X = Surge counter<br />

30 = 300 kA per phase (Standard)<br />

W= Terminal lug<br />

B = Busway application<br />

M = MCC application<br />

2 = Type 2 SPD<br />

(Default)<br />

Includes UL<br />

1283 EMI/<br />

RFI Filters<br />

0 = Type 1 SPD<br />

(Consult Factory Prior<br />

to Ordering)<br />

2 = Type 2 SPD<br />

(Default)<br />

Includes UL<br />

1283 EMI/<br />

RFI Filters<br />

0 = Type 1 SPD<br />

Example: TPS3CL130X002 = 10 Mode Type 2 SPD (Default) for a 208/120V panelboard<br />

with a surge current capacity of 300 kA per phase and a surge counter.<br />

When an option is not selected, include a zero (0) in the field.<br />

Available Accessories: Ordered Separately<br />

RMSIE = Remote monitor<br />

10-8<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


SPD - Surge Protective Devices<br />

TPS3 Integral or Internally Mounted SPDs<br />

Selection<br />

TPS3 02 and TPS3 L2<br />

(True or Discrete 10-Mode)<br />

Siemens TPS3 02 and L2 surge protective devices<br />

are designed for integration within our Revised P1<br />

power distribution panel boards.The TPS3 01 and<br />

L1 SPDs feature Ground Integrity Monitoring (GIM)<br />

diagnostics.<br />

TPS3 02 and TPS3 L2 Key Features<br />

n UL 1449-4 Type 2 SPD and UL 1283 Listed<br />

– Optional UL 1449 4th Edition Recognized Type 1<br />

n Type 1 / Type 2 SPD<br />

n 100 - 300 kA Per Phase Surge Current<br />

n Large block, individually fused, thermally<br />

protected, 50kA MOVs<br />

n 20 kA I n (Most models)<br />

n 200 kA SCCR (Most models)<br />

n UL 96A Lightning Protection Master Labeling<br />

compliant (@ 20 kA)<br />

n Large block, individually fused, thermally<br />

protected, 50kA MOVs<br />

n Every MOV is monitored, including N-G<br />

n Mounts internal to:<br />

– Revised P1 Lighting Panelboards<br />

n Consult factory for field retrofit in P1 panels<br />

n Modes of Protection: L-N, L-G, N-G, and L-L<br />

n All UL required OCP & safety coordination<br />

included<br />

– Type 1 SPDs intended for Line or Load side of<br />

Main Disconnect<br />

– Type 2 SPDs intended for Load side of<br />

Main Disconnect<br />

n Standard Monitoring: LED Indicators, Surge<br />

Counter, Dry Contacts, Audible Alarm w/ silence<br />

switch & test button<br />

n Dimensions: 11.6” x 5.7” x 4.9”<br />

(294.6 mm x 144.8 mm x 124.5 mm)<br />

n Weight: 4.55 lb. (2.06 kg)<br />

n 10 Year Product Warranty<br />

Available Options:<br />

n Direct bus connected<br />

Can be wired to a circuit breaker (consult<br />

factory at time of order or see installation manual<br />

for retrofit)<br />

Ordering Information<br />

Catalog # TPS3 02<br />

Voltage Code<br />

A = 120/240 V, 1Ø, 3W<br />

B = 120/240 V, 3Ø, 4W<br />

C = 120/208 V, 3Ø, 4W<br />

D = 240 V, 3Ø, 3W<br />

E = 277/480 V, 3Ø, 4W<br />

F = 480 V, 3Ø, 3W<br />

G = 600 V, 3Ø, 3W <br />

K = 380/220 V, 3Ø, 4W<br />

L = 600/347 V, 3Ø, 4W<br />

S = 400/230 V, 3Ø, 4W<br />

Surge Current (kA)<br />

10 = 100 kA per phase<br />

15 = 150 kA per phase<br />

20 = 200 kA per phase<br />

25 = 250 kA per phase<br />

30 = 300 kA per phase<br />

Ordering Information<br />

Catalog # TPS3 L2<br />

TPS3 02<br />

Options<br />

X = Surge counter (Standard)<br />

2 = Type 2 SPD (Default)<br />

Includes UL 1283 EMI/RFI Filters<br />

0 = Type 1 SPD<br />

(Consult Factory Prior to Ordering)<br />

Example: TPS3C0220X2 = Type 2 SPD (Default) for a 208/120V panelboard with a<br />

surge current capacity of 200 kA per phase and a surge counter.<br />

When an option is not selected, include a zero (0) in the field.<br />

Available Accessories: Ordered Separately<br />

RMSIE = Remote monitor<br />

Available in 100kA & 150 kA only<br />

TPS3 L2<br />

Voltage Code<br />

A = 120/240 V, 1Ø, 3W<br />

B = 120/240 V, 3Ø, 4W<br />

C = 120/208 V, 3Ø, 4W<br />

E = 277/480 V, 3Ø, 4W<br />

K = 380/220 V, 3Ø, 4W<br />

S = 400/230 V, 3Ø, 4W<br />

Surge Current (kA)<br />

15 = 150 kA per phase<br />

30 = 300 kA per phase<br />

Options<br />

X = Surge counter (Standard)<br />

2 = Type 2 SPD (Default)<br />

Includes UL 1283 EMI/RFI Filters<br />

0 = Type 1 SPD<br />

(Consult Factory Prior to Ordering)<br />

10 SPD<br />

Example: TPS3CL230X2 = 10 Mode Type 2 SPD (Default) for a 208/120 V panelboard<br />

with a surge current capacity of 300 kA per phase and a surge counter.<br />

When an option is not selected, include a zero (0) in the field.<br />

Available Accessories: Ordered Separately<br />

RMSIE = Remote monitor<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 10-9


SPD - Surge Protective Devices<br />

TPS3 External or Wall Mounted SPDs<br />

Selection<br />

TPS3 03<br />

TPS3 03 is a UL 1449 4th Edition 50 kA Type 1 compact surge<br />

protective device that can be used as a replacement secondary<br />

surge or lighting arrestors. Having a Type 1 designation<br />

allows for flexible electrical system connection location (line<br />

or load side) as well as UL 96A compliance (@ 20 kA I n ).<br />

TPS3 03 Key Features<br />

n UL 1449 4th Edition Listed Type 1<br />

n Type 1 Rated SPD<br />

n 50 kA Per Phase Surge Current<br />

n 20 kA I n (Most models)<br />

n 200 kA SCCR (Most models<br />

n UL 96A Lightning Protection Master Labeling compliant<br />

(@ 20 kA))<br />

n Every MOV is monitored<br />

n Mounts external to electrical distribution equipment<br />

– Recommend for Line Side or Load Side Applications<br />

n Standard compact NEMA 4X polycarbonate enclosure<br />

n Modes of Protection: L-N or L-G and L-L<br />

n Standard Monitoring: LED Indicator<br />

n Dimensions: 3.25” x 3.25” x 3.3”<br />

(82.6 mm x 82.6 mm x 83.8 mm)<br />

n Weight: 2 lb. (0.9 kg)<br />

n 2 Year Product Warranty<br />

Available Options:<br />

n Dry contacts & Audible Alarm (option “D”)<br />

n Neutral to Ground Protection (option “N”)<br />

TPS3 03<br />

Ordering Information<br />

Catalog # TPS3 03<br />

TPS3 01 DIN RAIL Mounting<br />

Voltage Code<br />

A = 120/240 V, 1Ø, 3W<br />

B = 120/240 V, 3Ø, 4W<br />

Surge Current (kA)<br />

05 = 50 kA per phase<br />

Options<br />

D = Dry contact<br />

& audible alarm<br />

C = 120/208 V, 3Ø, 4W<br />

N = Adds N-G<br />

D = 240 V, 3Ø, 3W<br />

Protection<br />

E = 277/480 V, 3Ø, 4W<br />

F = 480 V, 3Ø, 3W<br />

G = 600 V, 3Ø, 3W<br />

K = 380/220 V, 3Ø, 4W<br />

L = 600/347 V, 3Ø, 4W<br />

Example: TPS3C0305D0 = Type 1 SPD for a 208/120V application<br />

with a surge current capacity of 50 kA per phase, in a standard<br />

NEMA 4X enclosure with dry contacts and audible alarm option.<br />

When an option is not selected, include a zero (0) in the field.<br />

Available Accessories: Ordered Separately<br />

RMSIE = Remote monitor<br />

SPD<br />

10<br />

10-10<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


SPD - Surge Protective Devices<br />

TPS3 External or Wall Mounted SPDs<br />

Selection<br />

TPS3 03 DC<br />

TPS3 03 DC is available in 300VDC, 600VDC and 1000VDC versions, which<br />

are designed to protect photovoltaic electrical systems. Typical PV<br />

installation would be on the DC solar panel side and also on the AC side of<br />

the inverter/converter. AC voltage TPS3 03’s are also available. SPDs are<br />

highly recommended when lightning activity is present to protect<br />

sensitive electrical photovoltaic components.<br />

TPS3 03 DC is designed as a stand alone device in a NEMA 4X<br />

polycarbonate enclosure. Large block, thermally protected 50 kA MOVs<br />

are utilized. A green LED illuminates for diagnostic monitoring. TPS3 03<br />

DC comes standard with a Tri-Mount installation kit which allows it to be<br />

Nipple, DIN-rail or Bracket mounted.<br />

TPS3 09<br />

Diagram<br />

Dimensions<br />

Ordering Information<br />

Catalog # TPS3 0305<br />

Voltage Code<br />

M = 300 VDC P = 1000 VDC R = 600 VDC<br />

Tri-Mount Installation<br />

Mounting Kit Included<br />

Performance Data<br />

Siemens Part Number TPS3M0305 TPS3R0305 TPS3P0305<br />

Modes of Protection<br />

DC+ – DC- , DC+ – Ground, DC- – Ground<br />

Nominal Network Voltage Un 300VDC 600VDC 1000VDC<br />

Technology<br />

Large Block, Thermally Protected 50kA MOVs<br />

Maximum Continuous Operating Voltage DC Uc 425VDC 760VDC 1180VDC<br />

Maximum Surge Current (8/20 μs) Imax 50kA 50kA 50kA<br />

Nominal Discharge Current (8/20 μs) In 20kA 20kA 10kA<br />

Voltage Protection Level (3kA 8/20μs) Up


SPD - Surge Protective Devices<br />

TPS3 Integral or Internally Mounted SPDs<br />

Selection<br />

TPS3 05 and TPS3 L5<br />

(True or Discrete 10-Mode)<br />

Siemens TPS3 05 and L5 surge protective devices<br />

are designed for integration within our P4 and P5<br />

panelboards as well as distribution switchboards.<br />

The TPS3 01 and L1 SPDs feature Ground Integrity<br />

Monitoring (GIM) diagnostics.<br />

TPS3 05 and TPS3 L5 Key Features<br />

n UL 1449-4 Type 2 SPD and UL 1283 Listed<br />

– Optional UL 1449 4th Edition Listed Type 1<br />

n Type 1 / Type 2 SPD<br />

n 100 - 300 kA Per Phase Surge Current<br />

n 20 kA I n (Most models)<br />

n 200 kA SCCR (Most models)<br />

n UL 96A Lightning Protection Master Labeling<br />

compliant (@ 20 kA)<br />

n Large block, individually fused, thermally<br />

protected, 50kA MOVs<br />

n Every MOV is monitored, including N-G<br />

n Mounts internal to:<br />

– P4 & P5 panelboards and distribution<br />

switchboards<br />

n Modes of Protection: L-N, L-G, N-G, and L-L<br />

n All UL required OCP & safety coordination<br />

included<br />

– Type 1 SPDs intended for Line or Load side of<br />

Main Disconnect<br />

– Type 2 SPDs intended for Load side of<br />

Main Disconnect<br />

n Standard Monitoring: LED Indicators, Surge<br />

Counter, Dry Contacts, Audible Alarm w/ silence<br />

switch & test button<br />

n Dimensions: 10” x 17” x 6”<br />

(254 mm x 431.8 mm x 152.4 mm)<br />

n Weight: 9.4 lb. (4.2 kg)<br />

n Designed, manufactured & tested consistent with:<br />

– ANSI / IEEE C62.41.1-2002, C62.41.2-2002,<br />

C62.45-2002, C62.62-1010, C62.72-2007 and<br />

CSA C22.2 No. 269.1 and 269.2<br />

– 1992/2000 NEMA LS-1<br />

– NEC Article 285<br />

– IEC 61643, CE<br />

▪n 10 Year Product Warranty<br />

Ordering Information<br />

Catalog # TPS3 05<br />

TPS3 L5<br />

TPS3 05<br />

Voltage Code Surge Current (kA)<br />

Options<br />

A = 120/240 V, 1Ø, 3W 10 = 100 kA per phase<br />

B = 120/240 V, 3Ø, 4W 15 = 150 kA per phase<br />

X = Surge counter (Standard)<br />

C = 120/208 V, 3Ø, 4W 20 = 200 kA per phase 2 = Type 2 SPD (Default)<br />

D = 240 V, 3Ø, 3W 25 = 250 kA per phase<br />

Includes UL 1283 EMI/RFI Filters<br />

E = 277/480 V, 3Ø, 4W 30 = 300 kA per phase 0 = Type 1 SPD<br />

F = 480 V, 3Ø, 3W<br />

(Consult Factory Prior to Ordering)<br />

G = 600 V, 3Ø, 3W <br />

K = 380/220 V, 3Ø, 4W Example: TPS3C0530X2 = Type 2 SPD (Default) for a 208/120V power panel<br />

L = 600/347 V, 3Ø, 4W with a surge current capacity of 300 kA per phase and a surge counter.<br />

S = 400/230 V, 3Ø, 4W When an option is not selected, include a zero (0) in the field.<br />

Available Accessories: Ordered Separately<br />

RMSIE = Remote monitor<br />

Available in 100 kA & 150 kA only<br />

A B C N G<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

= Parallel MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

“True” or “Discrete”<br />

10-Mode SPD<br />

10<br />

SPD<br />

Panelboard Features:<br />

n Copper or aluminum bus<br />

MB or MLO<br />

Switchboard Features:<br />

n Copper or aluminum bus<br />

200% rated neutral bus for harmonic-rich<br />

applications<br />

CSA, UL 891, UL 67 and NEMA PB-2<br />

Ordering Information<br />

Catalog # TPS3 L5<br />

Voltage Code Surge Current (kA)<br />

Options<br />

A = 120/240 V, 1Ø, 3W 15 = 150 kA per phase<br />

B = 120/240 V, 3Ø, 4W 30 = 300 kA per phase<br />

X = Surge counter (Standard)<br />

C = 120/208 V, 3Ø, 4W<br />

2 = Type 2 SPD (Default)<br />

E = 277/480 V, 3Ø, 4W<br />

Includes UL 1283 EMI/RFI Filters<br />

K = 380/220 V, 3Ø, 4W<br />

0 = Type 1 SPD<br />

S = 400/230 V, 3Ø, 4W<br />

(Consult Factory Prior to Ordering)<br />

Example: TPS3C0530X2 = Type 2 SPD (Default) for a 208/120V power panel<br />

with a surge current capacity of 300 kA per phase and a surge counter.<br />

When an option is not selected, include a zero (0) in the field.<br />

Available Accessories: Ordered Separately<br />

RMSIE = Remote monitor<br />

10-12<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


SPD - Surge Protective Devices<br />

TPS3 Integral or Internally Mounted SPDs<br />

Selection<br />

TPS3 06 and TPS3 L6<br />

(True or Discrete 10-Mode)<br />

Siemens TPS3 06 and L6 surge protective devices<br />

are designed for integration within our SB1,<br />

SB2, SB3, Type RCS Switchboards, Low-voltage<br />

Switchgear, Motor Control Centers, and Busway<br />

Systems. The TPS3 01 and L1 SPDs feature Ground<br />

Integrity Monitoring (GIM) diagnostics.<br />

TPS3 06 and TPS3 L6 Key Features<br />

n UL 1449-4 Type 2 SPD and UL 1283 Listed<br />

– Optional UL 1449 4th Edition Listed Type 1<br />

n Type 1 / Type 2 SPD<br />

n 100 - 500 kA Per Phase Surge Current<br />

n 20 kA I n (Most models)<br />

n 200 kA SCCR (Most models)<br />

n UL 96A Lightning Protection Master Labeling<br />

compliant (@ 20 kA)<br />

n Large block, individually fused, thermally<br />

protected, 50kA MOVs<br />

n Every MOV is monitored, including N-G<br />

n Mounts internal to:<br />

– SB1, SB2, SB3 and Type RCS Switchboards<br />

– Type WL low-voltage switchgear<br />

– TIASTAR motor control centers -<br />

standard 12” bucket<br />

– STP series busplug on SX series busway<br />

n Modes of Protection: L-N, L-G, N-G, and L-L<br />

n All UL required OCP & safety coordination<br />

included<br />

– Type 1 SPDs intended for Line or Load side of<br />

Main Disconnect<br />

– Type 2 SPDs intended for Load side of<br />

Main Disconnect<br />

n Standard Monitoring: LED Indicators, Surge<br />

Counter, Dry Contacts, Audible Alarm w/ silence<br />

switch & test button, Rotary disconnect switch<br />

n Dimensions: 10.7” x 11.5” x 4.5”<br />

(271.8 mm x 292.1 mm x 114.3 mm)<br />

n Weight: 6.8 lb. (3.0 kg)<br />

n Designed, manufactured & tested consistent with:<br />

– ANSI / IEEE C62.41.1-2002, C62.41.2-2002,<br />

C62.45-2002, C62.62-1010, C62.72-2007 and<br />

CSA C22.2 No. 269.1 and 269.2<br />

– 1992/2000 NEMA LS-1<br />

– NEC Article 285<br />

– IEC 61643, CE<br />

n Designed, manufactured & tested consistent with:<br />

– ANSI / IEEE C62.41.1-2002, C62.41.2-2002,<br />

C62.45-2002, C62.62-1010, C62.72-2007 & CSA<br />

C22.2 No. 269.1 and .2<br />

– 1992/2000 NEMA LS-1<br />

– NEC Article 285<br />

– IEC 61643, CE<br />

n 10 Year Product Warranty<br />

Ordering Information<br />

Voltage Code<br />

A = 120/240 V, 1Ø, 3W<br />

B = 120/240 V, 3Ø, 4W<br />

C = 120/208 V, 3Ø, 4W<br />

D = 240 V, 3Ø, 3W <br />

E = 277/480 V, 3Ø, 4W<br />

F = 480 V, 3Ø, 3W<br />

G = 600 V, 3Ø, 3W <br />

K = 380/220 V, 3Ø, 4W<br />

L = 600/347 V, 3Ø, 4W<br />

S = 400/230 V, 3Ø, 4W<br />

Catalog # TPS3 06<br />

Surge Current (kA) Options<br />

10 = 100 kA per phase<br />

15 = 150 kA per phase<br />

20 = 200 kA per phase<br />

25 = 250 kA per phase<br />

30 = 300 kA per phase<br />

40 = 400 kA per phase<br />

50 = 500 kA per phase<br />

X = Surge counter<br />

(Standard)<br />

B = Busway application<br />

M = MCC application<br />

Example: TPS3C0120X002 = Type 2 SPD (Default) for a 208/120V panelboard<br />

with a surge current capacity of 200 kA per phase and a surge counter.<br />

When an option is not selected, include a zero (0) in the field.<br />

Available Accessories: Ordered Separately<br />

RMSIE = Remote monitor<br />

G voltage code only available in 200 & 250 kA<br />

Not available in 500 kA<br />

TPS3 L6<br />

Ordering Information<br />

TPS3 06<br />

Catalog # TPS3 L6<br />

Voltage Code Surge Current (kA) Options<br />

A = 120/240 V, 1Ø, 3W 15 = 150 kA per phase X = Surge counter<br />

B = 120/240 V, 3Ø, 4W 30 = 300 kA per phase (Standard)<br />

C = 120/208 V, 3Ø, 4W 45 = 450 kA per phase<br />

E = 277/480 V, 3Ø, 4W<br />

B = Busway application<br />

K = 380/220 V, 3Ø, 4W<br />

M = MCC application<br />

S = 400/230 V, 3Ø, 4W<br />

Example: TPS3CL645X2 = 10 mode Type 2 SPD (Default) for a 208/120V switchboard<br />

with a surge current capacity of 450 kA per phase and a surge counter.<br />

When an option is not selected, include a zero (0) in the field.<br />

Available Accessories: Ordered Separately<br />

RMSIE = Remote monitor<br />

2 = Type 2 SPD<br />

(Default)<br />

Includes UL<br />

1283 EMI/<br />

RFI Filters<br />

0 = Type 1 SPD<br />

(Consult Factory<br />

Prior to Ordering)<br />

A B C N G<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

= Parallel MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

“True” or “Discrete”<br />

10-Mode SPD<br />

2 = Type 2 SPD<br />

(Default)<br />

Includes UL<br />

1283 EMI/<br />

RFI Filters<br />

0 = Type 1 SPD<br />

(Consult Factory<br />

Prior to Ordering)<br />

10 SPD<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 10-13


SPD - Surge Protective Devices<br />

TPS3 External or Wall Mounted SPDs<br />

Selection<br />

TPS3 09<br />

TPS3 09 is a UL 1449 4th Edition 100 kA Type 1 compact<br />

multi-mode surge protective device that can be installed on<br />

either the line or load side of the electrical service. When<br />

installed at the electrical service entrance, it can be used for<br />

UL 96A compliance (@ 20 kA I n ).<br />

TPS3 09 Key Features<br />

n UL 1449 4th Edition Listed Type 1<br />

n Type 1 Rated SPD<br />

n 100 kA Per Phase Surge Current<br />

n 20 kA I n (Most models)<br />

n 200 kA SCCR (Most models)<br />

n UL 96A Lightning Protection Master Labeling compliant<br />

(@ 20 kA)<br />

n Every MOV is monitored, including N-G<br />

n Mounts external to electrical distribution equipment<br />

– Weatherproof hub included<br />

n Mounts internal to P1 panelboards & busway<br />

– P1 - Field retrofit or factory install<br />

– P2 and P3 - factory install only<br />

n Standard compact NEMA 4X polycarbonate enclosure<br />

n Modes of Protection: L-N, L-G, N-G, and L-L<br />

n Standard Monitoring: LED Indicators<br />

n Wire Size: Prewired with 3’ (91.4 cm) of #10 AWG<br />

n Dimensions: 8.3” x 3.6” x 3.0” (211 mm x 91 mm x 77 mm)<br />

n Weight: 3 lb. (1.4 kg)<br />

n 10 Year Product Warranty<br />

Available Options:<br />

n Dry contacts & Audible Alarm (option “D”)<br />

n Extended indicator light (option “E”)<br />

n Internal mounting in P1, P2 Panels (option “I”), requires<br />

TPS9IKITP1 or TPS9IKITP2 mounting bracket accessory.<br />

Ordering Information<br />

Catalog # TPS3 09<br />

Voltage Code<br />

A = 120/240 V, 1Ø, 3W<br />

B = 120/240 V, 3Ø, 4W<br />

C = 120/208 V, 3Ø, 4W<br />

D = 240 V, 3Ø, 3W<br />

E = 277/480 V, 3Ø, 4W<br />

F = 480 V, 3Ø, 3W<br />

G = 600 V, 3Ø, 3W<br />

K = 380/220 V, 3Ø, 4W<br />

L = 600/347 V, 3Ø, 4W<br />

S = 400/230 V, 3Ø, 4W<br />

Surge Current (kA)<br />

10 = 100 kA per phase<br />

Example: TPS3C0910D000<br />

= Type 1 SPD for a 208/120V<br />

panelboard with a surge current<br />

capacity of 100 kA per phase with<br />

standard NEMA 4X enclosure,<br />

dry contacts and audible alarm option.<br />

Available for field retrofit in P1 panels.<br />

TPS3 09<br />

Options<br />

E = Extended<br />

indicator light<br />

I = Internal<br />

mounting in<br />

P1, P2 panels a<br />

D = Dry<br />

Contact &<br />

audible alarm<br />

When an option is not selected, include a zero (0) in the field.<br />

Available Accessories: Ordered Separately<br />

RMSIE = Remote monitor<br />

XMFMKIT = Flush mount plate<br />

TPS9IKITP1 = Mounting bracket for installation in P1 panels<br />

TPS9IKITP2 = Mounting bracket for installation in P2 panels (factory install only)<br />

a Requires TPS9IKITP1 or TPS9IKITP2 mounting bracket accessory, see available<br />

Accessories. Prewired cables are extended from 3 to 6 feet.<br />

SPD<br />

10<br />

10-14<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


SPD - Surge Protective Devices<br />

TPS3 External or Wall Mounted SPDs<br />

Revised on 01/10/18<br />

Selection<br />

TPS3 11<br />

TPS3 11 is a UL 1449 3rd Edition Listed multi-mode Type 1<br />

surge protective device with a per phase surge current capacity<br />

that can be increased to 200 kA. In addition, this unit provides<br />

UL 1283 listed EMI/RFI or Sine Wave tracking filtering that will<br />

condition low energy L-N coupled noise. When installed at the<br />

electrical service entrance, it can be used for UL 96A compliance<br />

(@ 20 kA I n ).<br />

Standard monitoring includes protection status indication LEDs.<br />

Complete protection is intact when the status indicators are<br />

illuminated. When protection is lost, the status indicator will<br />

extinguish and the red service light will illuminate. An audible<br />

alarm and dry contacts are available monitoring options.<br />

A new diagnostic feature integrated within the TPS3 11 is<br />

Ground Integrity Monitoring or (GIM) diagnostic indication circuit.<br />

Ground Integrity Monitoring or (GIM) diagnostics monitors<br />

the health of the electrical system’s neutral to ground bond. If<br />

voltage is seen across neutral and ground, the phase indicators<br />

will remain illuminated, while the red service light begins to<br />

flash alerting the end user that the electrical system grounding<br />

needs to be checked and serviced. This feature can be remotely<br />

monitored when the optional dry contacts are included.<br />

Siemens TPS3s are one of the first in the industry to offer this<br />

power quality safety and performance indication.<br />

TPS3 11 Key Features<br />

n UL 1449-4 Type 2 SPD and UL 1283 Listed<br />

– Optional UL 1449 4th Edition Listed Type 1<br />

n Type 1 / Type 2 SPD<br />

n 100, 150, 200 kA Per Phase Surge Current<br />

n 20 kA I n (Most models)<br />

n 200 kA SCCR (Most models)<br />

n UL 96A Lightning Protection Master Labeling compliant<br />

(@ 20 kA)<br />

n Every MOV is monitored, including N-G<br />

n Mounts external to electrical distribution equipment<br />

n Standard NEMA 4X polycarbonate enclosure (UL 746C (f1),<br />

UL 94-5VA)<br />

n Modes of Protection: L-N, L-G, N-G, and L-L<br />

n Standard Monitoring: LED Indicators and Ground Integrity<br />

Monitoring diagnostics<br />

n Wire size: #8 AWG to #10 AWG<br />

n Dimensions: 6” x 6” x 4” (152 mm x 152 mm x 102 mm)<br />

n Weight: 5 lb. (2.27 kg)<br />

n 10 Year Product Warranty<br />

Available Options:<br />

n Dry contacts & Audible Alarm (option “D”)<br />

TPS3 11<br />

Ordering Information<br />

Catalog # TPS3 11<br />

Voltage Code<br />

A = 120/240 V, 1Ø, 3W<br />

B = 120/240 V, 3Ø, 4W<br />

C = 120/208 V, 3Ø, 4W<br />

D = 240 V, 3Ø, 3W<br />

E = 277/480 V, 3Ø, 4W<br />

F = 480 V, 3Ø, 3W<br />

G = 600 V, 3Ø, 3W <br />

K = 380/220 V, 3Ø, 4W<br />

L = 600/347 V, 3Ø, 4W<br />

S = 400/230 V, 3Ø, 4W<br />

Surge Current (kA)<br />

10 = 100 kA per phase<br />

15 = 150 kA per phase<br />

20 = 200 kA per phase<br />

Available Accessories: Ordered Separately<br />

RMSIE = Remote monitor<br />

KITFMXF = Flush mount plate<br />

Available in 100 kA per phase only<br />

Example: TPS3C1110D2 =<br />

Type 2 SPD (Default) for a<br />

208/120V application with a<br />

surge current capacity of 100 kA<br />

per phase, in a standard NEMA<br />

4X enclosure with dry contacts<br />

and audible alarm option.<br />

When option D is NOT selected,<br />

include a zero (0) in the field.<br />

Options<br />

2 = Type 2 SPD<br />

(Default)<br />

Includes UL<br />

1283 EMI/RFI<br />

Filters<br />

0 = Type 1 SPD<br />

(Consult Factory<br />

Prior to Ordering)<br />

D = Dry Contacts<br />

& audible<br />

alarm<br />

10 SPD<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 10-15


SPD - Surge Protective Devices<br />

10<br />

SPD<br />

TPS3 External or Wall Mounted SPDs<br />

TPS3 12 and TPS3 L12 (True or Discrete 10-Mode)<br />

TPS3 12 and TPS3 L12 are UL 1449-4 Type 2 and Optional<br />

UL 1449 4th Edition surge protective device with a per<br />

phase surge current capacity that can be increased to<br />

500 kA (TPS3 L12 up to 450 kA). For mission critical or<br />

high profile applications, the TPS3 L12 is our “True” or<br />

“Discrete” 10-mode style SPD providing the “Just in Case”<br />

assurance of directly connected L-L MOVs.<br />

Both TPS3 12 and TPS3 L12 are UL 1283 Listed<br />

incorporating EMI/RFI or Sine Wave tracking filtering<br />

designed to condition low energy L-N coupled noise. When<br />

installed at the electrical service entrance, it can be used for<br />

UL 96A compliance (@ 20 kA In).<br />

Standard monitoring includes protection status indication<br />

LEDs, audible alarm, and dry contacts. Complete protection<br />

is intact when the status indicators are illuminated. When<br />

protection is lost, the status indicator will extinguish, the<br />

red service light will illuminate, and the dry contacts will<br />

change state. An optional surge counter is available.<br />

A new diagnostic feature integrated within the TPS3 12 and<br />

TPS3 L12 is Ground Integrity Monitoring or (GIM) diagnostic<br />

indication circuit. Ground Integrity Monitoring or (GIM)<br />

diagnostics monitors the health of the electrical system’s<br />

neutral to ground bond. If voltage is seen across neutral and<br />

ground, the phase indicators will remain illuminated, while<br />

the red service light begins to flash alerting the end user<br />

that the electrical system grounding needs to be checked<br />

and serviced. This feature can be remotely monitored via<br />

the dry contact outputs. Siemens TPS3s are one of the<br />

first in the industry to offer this power quality safety and<br />

performance indication.<br />

TPS3 12 and TPS3 L12 Key Features<br />

n UL 1449-4 Type 2 SPD and UL 1283 Listed<br />

– Optional UL 1449 4th Edition Listed Type 1<br />

n Type 1 / Type 2 SPD<br />

n TPS3 12: 100 – 500 kA Per Phase Surge Current<br />

n TPS3 L12: 150, 300, 450 kA Phase Surge Current<br />

n 20 kA I n (Most models)<br />

n 200 kA SCCR (Most models)<br />

n UL 96A Lightning Protection Master Labeling compliant<br />

(@ 20 kA)<br />

n Every MOV is monitored, including N-G<br />

n Mounts external to electrical distribution equipment<br />

– Recommended for line side or load side applications<br />

n Standard NEMA 1/12/3R/04 ANSI 61 steel enclosure<br />

n TPS3 12 Modes of Protection – L-N, L-G, N-G, and L-L<br />

n TPS3 L12 Modes of Protection – L-N, L-G, N-G, and L-L<br />

(directly connected L-L elements)<br />

n Standard Monitoring:<br />

– LED Indicators<br />

– Ground Integrity Monitoring diagnostics<br />

– Dry Contacts<br />

– Audible alarm with silence switch and test button<br />

n Wire size: #8 AWG to 1/0<br />

n Dimensions: 12” x 12” x 7” (305 mm x 305 mm x 178 mm) <br />

n Weight: 20 lb. (9.07 kg) <br />

n 10 Year Product Warranty<br />

Available Options:<br />

n Internal rotary disconnect<br />

n Thru-door disconnect<br />

Ordering Information<br />

Catalog # TPS3 12<br />

Voltage Code<br />

A = 120/240 V, 1Ø, 3W<br />

B = 120/240 V, 3Ø, 4W<br />

C = 120/208 V, 3Ø, 4W<br />

D = 240 V, 3Ø, 3W <br />

E = 277/480 V, 3Ø, 4W<br />

F = 480 V, 3Ø, 3W <br />

G = 600 V, 3Ø, 3W <br />

K = 380/220 V, 3Ø, 4W<br />

L = 600/347 V, 3Ø, 4W<br />

S = 400/230 V, 3Ø, 4W<br />

A B C N G<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

= Parallel MOVs<br />

Surge Current (kA) Enclosure<br />

10 = 100 kA per phase<br />

15 = 150 kA per phase<br />

20 = 200 kA per phase<br />

25 = 250 kA per phase<br />

30 = 300 kA per phase<br />

40 = 400 kA per phase<br />

50 = 500 kA per phase<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

“True” or “Discrete”<br />

10-Mode SPD<br />

Ordering Information<br />

Catalog # TPS3 L12<br />

0 = Standard NEMA<br />

1/12/3R/4 Steel<br />

V = NEMA 4X nonmetallic<br />

S = NEMA 4X stainless steel<br />

F = NEMA 1 flush mount<br />

P = NEMA 1 screwcover pullbox<br />

with extended display on 6ft<br />

cable for line side mounting<br />

in SWBD/SWGR<br />

Example: TPS3C12100XD2 = Type 2 SPD (Default) for a 208/120V application<br />

with a surge current capacity of 100kA per phase, in a standard NEMA 1/12/3R/4<br />

enclosure with a surge counter and internal rotary disconnect option.<br />

When option X, T, or D are NOT selected, include a zero (0) in the field.<br />

Available Accessories: Ordered Separately<br />

RMSIE = Remote monitor<br />

Not available in 500 kA<br />

Available in 100 kA, 150 kA, 200 kA & 250 kA only<br />

Voltage Code<br />

A = 120/240 V, 1Ø, 3W<br />

B = 120/240 V, 3Ø, 4W<br />

C = 120/208 V, 3Ø, 4W<br />

E = 277/480 V, 3Ø, 4W<br />

K = 380/220 V, 3Ø, 4W<br />

S = 400/230 V, 3Ø, 4W<br />

Surge Current (kA) Enclosure<br />

15 = 150 kA per phase<br />

30 = 300 kA per phase<br />

45 = 450 kA per phase<br />

TPS3 L12<br />

0 = Standard NEMA<br />

1/12/3R/4 Steel<br />

V = NEMA 4X nonmetallic<br />

S = NEMA 4X stainless steel<br />

F = NEMA 1 flush mount<br />

P = NEMA 1 screwcover pullbox<br />

with extended display on 6ft<br />

cable for line side mounting<br />

in SWBD/SWGR<br />

Example: TPS3CL12150XD2 = 10 Mode, Type 2 SPD (Default) for a 208/120V<br />

application with a surge current capacity of 150kA per phase, in a standard NEMA<br />

1/12/3R/4 enclosure with a surge counter and internal rotary disconnect option.<br />

When an option is NOT selected, include a zero (0) in the field.<br />

Available Accessories: Ordered Separately<br />

RMSIE = Remote monitor<br />

Selection<br />

TPS3 12<br />

Options<br />

2 = Type 2 SPD<br />

(Default)<br />

Includes<br />

UL 1283 EMI/<br />

RFI Filters<br />

0 = Type 1 SD<br />

(Consult Factory<br />

Prior to Ordering)<br />

D = Internal rotary<br />

disconnect<br />

T = Thru-door<br />

disconnect<br />

X = Surge<br />

Counter<br />

(Standard)<br />

Options<br />

2 = Type 2 SPD<br />

(Default)<br />

Includes<br />

UL 1283 EMI/<br />

RFI Filters<br />

0 = Type 1 SD<br />

(Consult Factory<br />

Prior to Ordering)<br />

D = Internal rotary<br />

disconnect<br />

T = Thru-door<br />

disconnect<br />

X = Surge<br />

Counter<br />

(Standard)<br />

Internal disconnect options and other NEMA ratings may increase enclosure size and weight<br />

10-16<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


SPD - Surge Protective Devices<br />

TPS3 External or Wall Mounted SPDs<br />

Selection<br />

TPS3 15 and TPS3 L15 (True or Discrete 10-Mode)<br />

TPS3 15 and TPS3 L15 are UL 1449-4 Type 2 and Optional<br />

UL 1449 4th Edition surge protective device with a per phase<br />

surge current capacity that can be increased to 1000 kA<br />

(TPS3 L15 up to 900 kA). For mission critical or high profile<br />

applications, the TPS3 L15 is our “True” or “Discrete”<br />

10-mode style SPD providing the “Just in Case” assurance of<br />

directly connected L-L MOVs.<br />

Both TPS3 15 and TPS3 L15 are UL 1283 Listed<br />

incorporating EMI/RFI or Sine Wave tracking filtering<br />

designed to condition low energy L-N coupled noise. When<br />

installed at the electrical service entrance, it can be used for<br />

UL 96A compliance (@ 20 kA I n ).<br />

Standard monitoring includes protection status indication<br />

LEDs, audible alarm, and dry contacts. Complete protection<br />

is intact when the status indicators are illuminated. When<br />

protection is lost, the status indicator will extinguish, the red<br />

service light will illuminate, and the dry contacts will change<br />

state. An optional surge counter is available.<br />

A new diagnostic feature integrated within the TPS3 15 and<br />

TPS3 L15 is Ground Integrity Monitoring or (GIM) diagnostic<br />

indication circuit. Ground Integrity Monitoring or (GIM)<br />

diagnostics monitors the health of the electrical system’s<br />

neutral to ground bond. If voltage is seen across neutral and<br />

ground, the phase indicators will remain illuminated, while the<br />

red service light begins to flash alerting the end user that the<br />

electrical system grounding needs to be checked and serviced.<br />

This feature can be remotely monitored via the dry contact<br />

outputs. Siemens TPS3s are one of the first in the industry to<br />

offer this power quality safety and performance indication.<br />

TPS3 15 and TPS3 L15 Key Features<br />

n UL 1449-4 and UL 1283 Listed<br />

– Optional UL 1449 4th Edition Listed Type 1<br />

n Type 1 / Type 2 SPD<br />

n TPS3 15: 400 – 1000 kA Per Phase Surge Current<br />

n TPS3 L15: 600 and 900 kA Phase Surge Current<br />

n 20 kA I n (Most models)<br />

n 200 kA SCCR (Most models)<br />

n UL 96A Lightning Protection Master Labeling compliant<br />

(@ 20 kA)<br />

n Every MOV is monitored, including N-G<br />

n Mounts external to electrical distribution equipment<br />

– Recommended for line side or load side applications<br />

n Standard NEMA 1/12/3R/04 ANSI 61 steel enclosure<br />

n TPS3 15 Modes of Protection – L-N, L-G, N-G, and L-L<br />

n TPS3 L15 Modes of Protection – L-N, L-G, N-G, and L-L<br />

(directly connected L-L elements)<br />

n Internal rotary disconnect switch included<br />

n Standard Monitoring:<br />

– LED Indicators<br />

– Ground Integrity Monitoring diagnostics<br />

– Dry Contacts<br />

– Audible alarm with silence switch and test button<br />

n Wire size: #8 AWG to 1/0<br />

n Dimensions: 20” x 20” x 7” (508 mm x 508 mm x 178 mm) <br />

n Weight: 64 lb. (29 kg) <br />

n 10 Year Product Warranty<br />

Available Options:<br />

n Thru-door disconnect<br />

TPS3 15<br />

Ordering Information<br />

Catalog # TPS3 15<br />

Voltage Code<br />

A = 120/240 V, 1Ø, 3W<br />

B = 120/240 V, 3Ø, 4W<br />

C = 120/208 V, 3Ø, 4W<br />

D = 240 V, 3Ø, 3W <br />

E = 277/480 V, 3Ø, 4W<br />

F = 480 V, 3Ø, 3W <br />

G = 600 V, 3Ø, 3W <br />

K = 380/220 V, 3Ø, 4W<br />

L = 600/347 V, 3Ø, 4W<br />

S = 400/230 V, 3Ø, 4W<br />

Surge Current (kA)<br />

40 = 400 kA per phase <br />

50 = 500 kA per phase <br />

60 = 600 kA per phase<br />

80 = 800 kA per phase<br />

1K = 1000 kA per phase<br />

Enclosure<br />

0 = Standard NEMA<br />

1/12/3R/4 Steel<br />

V = NEMA 4X nonmetallic<br />

S = NEMA 4X stainless steel<br />

F = NEMA 1 flush mount<br />

P = NEMA 1 screwcover pullbox<br />

with extended display on 5ft<br />

cable for line side mounting<br />

in SWBD/SWGR<br />

Example: TPS3C1560SX02 = Type 2 SPD (Default) for a 208/120V application<br />

with a surge current capacity of 600 kA per phase, in a NEMA 4X stainless steel<br />

enclosure with a surge counter and standard disconnect switch.<br />

When an option is NOT selected, include a zero (0) in the field.<br />

Available Accessories: Ordered Separately<br />

RMSIE = Remote monitor<br />

Available in G voltage code only<br />

Available in 600 kA & 800 kA only<br />

Available in 400 kA & 500 kA only<br />

A B C N G<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

= Parallel MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

MOVs<br />

“True” or “Discrete”<br />

10-Mode SPD<br />

Ordering Information<br />

Catalog # TPS3 L15<br />

Voltage Code<br />

A = 120/240 V, 1Ø, 3W<br />

B = 120/240 V, 3Ø, 4W<br />

C = 120/208 V, 3Ø, 4W<br />

E = 277/480 V, 3Ø, 4W<br />

K = 380/220 V, 3Ø, 4W<br />

S = 400/230 V, 3Ø, 4W<br />

Surge Current (kA) Enclosure<br />

60 = 600 kA per phase<br />

90 = 900 kA per phase<br />

TPS3 L15<br />

0 = Standard NEMA<br />

1/12/3R/4 Steel<br />

V = NEMA 4X nonmetallic<br />

S = NEMA 4X stainless steel<br />

F = NEMA 1 flush mount<br />

P = NEMA 1 screwcover pullbox<br />

with extended display on 5ft<br />

cable for line side mounting<br />

in SWBD/SWGR<br />

Example: TPS3CL15600X02 = 10 Mode, Type 2 SPD (Default) for a 208/120V<br />

application with a surge current capacity of 600 kA per phase, in a standard<br />

NEMA 1/12/3R/4 enclosure with a surge counter.<br />

When an option is NOT selected, include a zero (0) in the field.<br />

Available Accessories: Ordered Separately<br />

RMSIE = Remote monitor<br />

Other NEMA ratings may increase enclosure size and weight.<br />

Options<br />

2 = Type 2 SPD<br />

(Default)<br />

Includes<br />

UL 1283 EMI/<br />

RFI Filters<br />

0 = Type 1 SD<br />

(Consult Factory<br />

Prior to Ordering)<br />

T = Thru-door<br />

disconnect<br />

X = Surge<br />

Counter<br />

(Standard)<br />

Options<br />

2 = Type 2 SPD<br />

(Default)<br />

Includes<br />

UL 1283 EMI/<br />

RFI Filters<br />

0 = Type 1 SD<br />

(Consult Factory<br />

Prior to Ordering)<br />

T = Thru-door<br />

disconnect<br />

X = Surge<br />

Counter<br />

(Standard)<br />

10 SPD<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 10-17


SPD - Surge Protective Devices<br />

Surge Protective Devices<br />

FAQ<br />

Frequently Asked Questions<br />

10<br />

SPD<br />

What is a surge protective device or SPD?<br />

A Surge Protective Device is a device that attenuates<br />

(reduces in magnitude) random, high energy, short duration<br />

overvoltages caused by lightning, utilities, switching, etc.<br />

Such anomalies occur in the form of voltage and current<br />

spikes with a duration of less than half an ac voltage cycle.<br />

These high energy power spikes can damage sensitive<br />

electronic equipment, such as computers, instrumentation,<br />

and process controllers.<br />

How do SPDs work?<br />

Surge Suppressors divert high energy power away from a<br />

load by providing a lower impedance path to common point<br />

earth ground. This is similar in concept to pressure relief<br />

valves that protect water heaters from overpressure. Surge<br />

suppressors used most often for protection of AC Power have<br />

metal oxide varistors (MOVs) connected in parallel.<br />

Where are SPDs installed?<br />

AC voltage surge suppressors are typically installed in these<br />

three areas: at a utility service entrance for protection of an<br />

entire facility, in distribution panelboards and switchboards<br />

for protection of sensitive downstream loads; connected to<br />

a wall outlet for individual protection of a specific piece of<br />

equipment, such as a computer or solid-state controller.<br />

What is clamping voltage?<br />

Clamping voltage, also referred to as peak let through or<br />

suppressed voltage rating, is the amount of voltage a surge<br />

suppressor permits to pass through it to the attached load<br />

during a transient event. Clamping voltage is a performance<br />

measurement of a surge suppressor’s ability to attenuate<br />

a transient. For example, a surge suppressor might limit a<br />

6,000V surge so that only 700V is ‘visible’ to the load. The<br />

Voltage Protection Rating is 700V, commonly called Clamping<br />

Voltage. This performance value is confirmed by Underwriters<br />

Laboratories during tests conducted while evaluating a surge<br />

suppressor for listing.<br />

What is surge current capacity?<br />

Surge current capacity is the maximum amount of surge<br />

current that a surge suppressor can pass for a single transient<br />

event. This level is used to indicate the protection capacity<br />

of a particular surge suppressor design, and when specifying<br />

surge suppressors. For example, in a high exposure<br />

application with very large transients present from lightning,<br />

a higher level surge current capacity might be desired. Be<br />

aware that surges have natural limitations and that larger<br />

surge current capacity tends to add redundancy rather than<br />

the implied ability to handle an extremely large surge. For<br />

example, an entire lightning strike cannot go through wire; it<br />

is much like trying to put the output from a fire hose through<br />

a soda straw. Consequently, suppressors do not need to be<br />

sized for entire lightning strikes. There are valid reasons for<br />

adding excess surge current capacity for redundancy reasons.<br />

What types of components make up a SPD?<br />

The device most commonly used in AC voltage surge<br />

suppressors are MOVs, a solid-state device made of zinc<br />

oxide materials. MOVs are voltage sensitive semiconductors,<br />

which change from high impedance to low impedance when<br />

sensing an overvoltage condition. MOVs are packaged for<br />

specific voltages and current handling capacities. Other<br />

devices (more typically found in DC applications) include single<br />

junction diodes and gas tubes that ionize at preset voltages.<br />

What features should be considered when<br />

selecting SPDs?<br />

Two important areas to consider during the selection of a<br />

surge suppressor are performance and safety, and include<br />

the following criteria: Performance: 1) surge current capacity;<br />

and 2) clamping voltage. Safety: 1) the individual suppression<br />

circuit should be fused to clear an inoperative MOV during an<br />

extreme transient event, and 2) provide overcurrent protection<br />

for the surge suppressor during a fault condition.<br />

What surge current capacity is required?<br />

Surge current capacity is dependent on the application and<br />

the amount of required protection. The selection of the proper<br />

surge suppressor is not an exact science and cannot be scientifically<br />

calculated from a standard algorithm.<br />

Questions to consider when specifying the proper surge<br />

current capacity for a surge suppressor include:<br />

n What is the geographic location of the facility and it’s<br />

susceptibility to lightning? (For example, Florida is a highlightning<br />

area; California is a low lightning area.)<br />

n Is the facility in a rural or urban setting?<br />

n Is the facility the tallest building around?<br />

n Is the facility at the end of the utility grid?<br />

n If it is an existing facility, what is its power quality history?<br />

Based on the above information, and taking into account the<br />

cost of protection, the following is a good rule of thumb: a<br />

surge suppressor with a surge current capacity in the range of<br />

100kA to 300kA would be used in conjunction with a service<br />

entrance panelboard or switchboard. A surge suppressor with<br />

a surge current capacity in the range of 100kA to 200kA would<br />

be used in conjunction with a downstream panelboard<br />

10-18<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Panelboards<br />

SPEEDFAX TM<br />

Section<br />

Scan to connect<br />

online to the<br />

most up-todate<br />

version of<br />

this Section of<br />

SPEEDFAX.<br />

Circuit<br />

Breaker<br />

Lighting<br />

Panel<br />

Type P1<br />

Circuit<br />

Breaker<br />

Lighting or<br />

Distribution<br />

Panel Types<br />

P2/P3<br />

Circuit<br />

Breaker<br />

Distribution<br />

Panel Type<br />

P4/P5<br />

c o n t e n t s<br />

Features, Reference Guide & General Specifications 11-2 – 11-8<br />

Unassembled Panelboards 11-9 – 11-13<br />

Factory Assembled Panelboard Coding System 11-16<br />

Factory Assembled Panelboard Pricing 11-17<br />

Type P1 11-18 – 11-26<br />

Specifications 11-18<br />

Main Lug and Main Breaker 11-19<br />

Branch and Subfeed Breakers 11-20<br />

Modifications and Additions 11-24 – 11-25<br />

Enclosure Dimensions 11-26<br />

Type P2 11-27 – 11-39<br />

Specifications 11-27<br />

Enclosure Selection/ Dimensions 11-28 – 11-29<br />

Main Breaker and Subfeed Breakers 11-30<br />

Branch Breakers 11-31<br />

Main Lug and Main Breaker 11-32<br />

Modifications and Additions 11-33 – 11-38<br />

Enclosure Dimensions 11-39<br />

Type P3 11-40 – 11-50<br />

Specifications 11-40<br />

Enclosure Selection/ Dimensions 11-41<br />

Alternate Main, Branch and Subfeed Breakers 11-42 – 11-43<br />

Main Lug and Main Breaker 11-44 – 11-45<br />

Modifications and Additions 11-46 – 11-49<br />

Enclosure Dimensions 11-50<br />

3VA Breaker Reference Info used in Panelboards P1 thru P5 11-51 – 11-69<br />

Type P4 11-70 – 11-83<br />

Specifications 11-70<br />

Enclosure Selection 11-70 – 11-72<br />

Main Lug and Main Breaker 11-73<br />

Main Switch and Alternate Main Breakers 11-74<br />

Branch Devices – Circuit Breaker and Switch 11-75 – 11-77<br />

Modifications and Additions 11-78 – 11-82<br />

Enclosure Dimensions 11-83<br />

Type P5 11-84 – 11-97<br />

Specifications 11-84<br />

Enclosure Selection 11-85<br />

Main Lug and Main Breaker 11-86<br />

Alternate Main Breaker and Main Switch 11-87<br />

Branch Breakers 11-88 – 11-89<br />

Branch Switches 11-90<br />

Modifications and Additions 11-91 – 11-96<br />

Enclosure Dimensions 11-97<br />

Column Type Panelboards 11-98 – 11-101<br />

Telephone and Equipment Cabinets 11-102<br />

Panelboard Modifications and Additions 11-103 – 11-105<br />

Enclosures—Relay Cabinets, NEMA 4X 11-103<br />

Remote Switches—ASCO, LEN 11-103<br />

Enclosure, Door, & Trim Modifications 11-104<br />

Circuit Breaker Accessories & Panel Skirts 11-105<br />

Coordination Panels 11-106 – 11-113<br />

11 PANELBOARDS<br />

(Section was last modified on 02/19/20)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-1


Panelboards<br />

Revised on 05/15/18<br />

Introduction<br />

General<br />

11<br />

PANELBOARDS<br />

This generation of panelboards from Siemens offers the<br />

high level of engineering and innovation you’ve come to<br />

expect from the leader in power distribution technology.<br />

The “P Series” line of panelboards offers a stepped approach<br />

to power distribution.<br />

Additional strength has been added to an already rugged and<br />

durable panelboard family. Engineered specifically to provide<br />

maximum flexibility, the new designs simplify wiring and<br />

reduce material requirements making them easier to install<br />

and less costly than competitive products. At the heart of the<br />

product line is the extensive research and technology found<br />

among Siemens circuit protection devices – both fusible<br />

switches and molded case circuit breakers.<br />

• Sized more like a lighting panel, the P3 packs the power of a<br />

distribution panel in a space-saving, highly flexible design.<br />

• The P4 is a mid-sized distribution panel that allows both<br />

fusible and circuit breaker branch and main devices.<br />

• The powerful P5 anchors the high end of the series. With<br />

larger fusible and circuit breaker branch and main devices,<br />

the venerable P5 delivers maximum power and flexibility to<br />

larger distribution systems.<br />

Siemens also offers a number of specialty panels, like column<br />

panels, SEM3 (Embedded Micro Metering Module TM ),<br />

Disaggregation Panels (which are California Title-24 compliant),<br />

and others. Don’t see a panel to meet your requirements? Ask<br />

your Siemens representative about our custom capabilities.<br />

The line is anchored by the innovative P1. Featuring the industry’s<br />

most flexible designs, the P1 virtually eliminates common<br />

errors, such as feed direction, and main lug versus main breaker.<br />

Increasing distribution is simplified by the ability to add<br />

feed-thru lugs. The Revised P1 design introduced in January<br />

2015 has added Extended Circuits up to 66 and has available<br />

smaller Enclosures with no Subfeed option for added flexibility<br />

Subsequent steps in the P Series offer increased capacity and<br />

more design options:<br />

• The highly flexible P2 provides options to fit the most<br />

demanding specifications.<br />

Key Panelboard Features<br />

Features Overview<br />

P Series lighting panel features include Fas-Latch trim, which<br />

is popular among installers; the jacking screw system, that<br />

permits adjustments even after wiring has been installed; our<br />

exclusive split neutral, and more. Many panelboards have the<br />

capability of mixing and matching breakers of different sizes<br />

and ratings – or changing from main lug to main breaker, or<br />

adding subfeed breakers without changing the box size. Other<br />

models accept a wide range of fuse types, including Siemens<br />

exclusive Vacu-Break ® technology.<br />

P1 P2 P3 P4 P5<br />

Lighting And Appliance Applications (Pre 2008 NEC) ● ● ● ● ●<br />

Power Panelboard Applications — ● ● ● ●<br />

Convertible From Top Feed To Bottom Feed<br />

Or Vice Versa<br />

● — — — —<br />

Change From Main Lug To Main Breaker Or Add<br />

Subfeed Without Changing Enclosure Size ● — — — —<br />

Space-Saving, Horizontally Mounted Main Breaker Up To 250 Amps Up To 250 Amps Up To 250 Amps • •<br />

Short-Circuit Rating Label Giving Performance Level ● ● ● ● ●<br />

Standard Aluminum Ground Assembly ● ● ● ● ●<br />

Blank End-Walls Standard ● ● ● ● ●<br />

Bolted Current-Carrying Parts ● ● ● ● ●<br />

Split Neutral ● — ● ● ●<br />

Connection Accessible From Front ● ● ● ● ●<br />

Screw-Type Mechanical Lugs ● ● ● ● ●<br />

Time-Reducing Wing Nuts To Secure Interior<br />

Without Tools<br />

● ● ● ● ●<br />

Main and Branch Devices Connected With Case-<br />

Hardened Hardware<br />

● ● ● ● ●<br />

Flush Lock, Concealed Door Hinges/Trim Screws ● ● ● — —<br />

Symmetrical Interior Mounting Studs To Eliminate<br />

Upside-Down Mounting of Box<br />

● ● ● ● ●<br />

Interior Height Adjustment For Flush Applications ● ● ● ● ●<br />

Mix and Match Fusible Switch Circuit Breaker Capability — — — ● ●<br />

Shallow Depth 5.75" 5.75" 7.75" 10.00" 12.75"<br />

Accepts A Wide Range Of Fuse Types — — — ● ●<br />

Accepts Vacu-Break Fusible Switch — — — ● ●<br />

Accepts A Wide Range Of Circuit Breakers ● ● ● ● ●<br />

Accepts PDS ACCESS Communications Tie-In — ● ● ● ●<br />

Optional Compression Lugs ● ● ● ● ●<br />

• Standard<br />

KO’s available on P1 and P2 – 5.75" Deep x 20" Wide<br />

boxes and P3 7.75" deep X 24" wide boxes.<br />

Panelboards equipped with Siemens Sensitrip<br />

Circuitbreakers or Power Meters can be integrated into<br />

SIEMENS PDS ACCESS Electrical Monitoring System.<br />

For Revised P1, only when Subfeed Space is selected,<br />

Interior Part Number ends with "T". When "N" is at end<br />

there is no Subfeed Space available<br />

11-2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Panelboards<br />

General Specifications<br />

Revised on 04/30/19<br />

General<br />

Class CTL Panelboards (when applicable)<br />

Class CTL panelboards incorporate physical features which, in<br />

conjunction with the physical size, configuration, or other means<br />

provided in Class CTL circuit breakers, are designed to prevent<br />

the installation of more over current protective poles than the<br />

number for which the device is designed and rated, per UL 67<br />

and National Electrical Code (NEC) NFPA70.<br />

Service Entrance Equipment<br />

When a panelboard is used as service entrance equipment, it<br />

must be located near the point of entrance of building supply<br />

conductors. In a main lugs only panel, the number of breakers<br />

or switches directly connected to the main bus must be limited<br />

to six. In a panel having a main breaker or main switch, the<br />

number of circuits are not limited except as may be provided<br />

under other panelboard requirements, i.e., lighting and<br />

appliance branch circuit panelboards. Also, panels must include<br />

a connector for bonding and grounding the neutral conductor.<br />

UL67 requires Service Entrance Barriers for all Panels used for<br />

Service Entrance. Siemens includes these barriers in all Factory<br />

assembled panels and also has available Field Installable kits<br />

when needed.<br />

Panelboard Code Data (where applicable)<br />

Lighting and appliance branch circuit panelboards were included<br />

in editions of the National Electrical Code prior to 2008. The<br />

NEC no longer distinguishes between lighting and appliance<br />

panelboards and power panelboards; therefore, eliminating the<br />

42 circuit branch circuit limitation. Adoption of this code vary by<br />

a state or local jurisdiction. Consult the local code authorities to<br />

determine if this has been adopted in that area.<br />

Integrated Equipment Short Circuit Rating<br />

The term “Integrated Equipment Short Circuit Rating” refers<br />

to the application of series connected circuit breakers in a<br />

combination that allows some breakers to have lower individual<br />

interrupting ratings than the available fault current. This is<br />

permitted as long as the series combination has been tested<br />

and certified by UL.<br />

Standards<br />

NEC: 2014 (where accepted)<br />

NEMA: PB1.1<br />

UL: 67, 50 and 50E. Listed by Underwriter’s Laboratories,<br />

Inc., under “Panelboards” File #E2269, and #E4016.<br />

Meets Federal Specification W-P-115c.<br />

Wire Connectors<br />

Standard wire connectors in Siemens panels are suitable for<br />

copper or aluminum cables rated 60/75 degree. Copper main<br />

lugs are a price-added option for most panel types and some<br />

Circuit Breakers (check with Siemens sales for availability). It<br />

should be noted that most copper lugs will only accept copper<br />

cables. Some applications, 100% rated devices in particular,<br />

require that the cable and connectors be rated 90 degree but<br />

are sized to the 75 degree tables.<br />

Standard ground connectors are also suitable for copper or<br />

aluminum wire. Ground connector assemblies (EGK, IGK) have<br />

(6) 1/0 max. and (15) #6 max. connections. The 1/0 holes are<br />

capable of connecting up (3) #10 max. wires. The #6 holes<br />

can accept up to (2) #12 max. wires. Copper ground<br />

assemblies (ECGK, ICGK) are rated for copper wire only and<br />

have the same wiring capacity as the Al/Cu connectors.<br />

Standard neutrals, like standard main lugs, are also rated for<br />

copper or aluminum wire. The neutral cross bar material follows<br />

the selection bus. Copper neutral lugs are rated for copper<br />

cable only and available as a price added option.<br />

Lug Data<br />

Space Required for Mounting of Double Panels<br />

Wall Wall<br />

Shown mounted in wall<br />

Shown mounted on surface of wall<br />

Use two or more panelboards with feed-thru or subfeed lugs<br />

when:<br />

1. Lighting and appliance panelboards are required with more<br />

than 42 circuits in areas where the zone code has not been<br />

accepted.<br />

2. More circuit mounting space is required than is provided in<br />

the largest box size<br />

Feed-Thru Lugs<br />

Fig. G-1 Fig. G-2<br />

Subfeed Lugs or Double Lug<br />

Feed-thru lugs are mounted at the opposite end of the main<br />

bus from the main lugs or main breaker and are used to connect<br />

two or more panelboards to the incoming feeder. The<br />

feeder cables are brought into Panelboard 1 and connected to<br />

the main lugs or main breaker. Cables interconnecting the two<br />

panelboards are connected to the feed-thru lugs in Panelboard1<br />

and are carried over the main lugs in Panelboard 2. This arrangement<br />

could be reversed with the main lugs located at the top<br />

and the feed-thru lugs at the bottom of the panel.<br />

Subfeed lugs are mounted directly beside the main incoming<br />

lugs and are used to connect two or more panelboards<br />

to the incoming feeder. The feeder cables are brought into<br />

Panelboard 1 and connected to the main lugs. Another set of<br />

cables that are the same size are connected to the subfeed<br />

lugs of Panelboard 1 and are carried over the main lugs of<br />

Panelboard 2.<br />

Note: P1 panelboards do not have subfeed lugs available.<br />

If this configuration is needed, move to a P2 or P3<br />

panelboard.<br />

11 PANELBOARDS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-3


Panelboards<br />

General Specifications<br />

Revised on 04/30/19<br />

General<br />

11<br />

PANELBOARDS<br />

Bussing Sequence<br />

Interiors are designed to accommodate<br />

top or bottom feed. Regardless of<br />

which is specified, the uppermost pole<br />

is always on “A” phase; the second<br />

pole down is always on “B” phase, and<br />

the third pole down is always on ”C”<br />

phase (assuming 3Ø panel).<br />

As standard, branch breakers shall be<br />

mounted at the top of the panel with<br />

“spaces” at the bottom, regardless of<br />

the direction panel is fed.<br />

All breakers have bolted connections<br />

except plug-in type. The panel design<br />

provides bracing up to 200,000A IR UL<br />

short circuit rating. Case-hardened, high<br />

performance, thread rolling screws are<br />

used on branch bus.<br />

Circuit Breaker Lighting<br />

Panel Type P1<br />

Circuit Breaker Lighting or<br />

Distribution Panel Types P2/P3<br />

Circuit Breaker Distribution<br />

Panel Type P4/P5<br />

Fusible Switch Distribution<br />

Panel Type P4/P5<br />

Panelboard Ratings (Updated June 2014 with release of Revised P1 design)<br />

Description P1 Revised P2 P3 P4 P5<br />

Max. Voltage 480Y/277V AC Max. 600V AC Max.<br />

600V AC Max.<br />

600V AC Max. 600V AC Max.<br />

600Y/347V AC <br />

250V DC Max.<br />

250V DC Max.<br />

250V DC Max. 250V DC Max.<br />

System<br />

Mains<br />

Main Lugs<br />

Main Breaker<br />

Main Switch<br />

Circuits<br />

1-Phase, 2-wire<br />

1-Phase, 3-wire<br />

3-Phase, 3-wire<br />

3-Phase, 4-wire<br />

125A-400A<br />

100A-400A<br />

—<br />

18, 30, 42, 54, 66 (250A)<br />

30, 42, 54, 66 (400A)<br />

1-Phase, 2-wire<br />

1-Phase, 3-wire<br />

3-Phase, 3-wire<br />

3-Phase, 4-wire<br />

125A-600A<br />

100A-600A<br />

—<br />

1-Phase, 2-wire<br />

1-Phase, 3-wire<br />

3-Phase, 4-wire<br />

3-Phase, 3-wire<br />

250A-800A<br />

225A-600A<br />

—<br />

1-Phase, 3-wire<br />

3-Phase, 4-wire<br />

3-Phase, 3-wire<br />

400A-1200A<br />

400A-800A<br />

—<br />

18, 30, 42, 54, 66<br />

— — —<br />

78, 90 <br />

Branch Ratings 15-125A 15-400A 15-400A 15-800A MCCB<br />

30-200A Fusible<br />

Branch<br />

Disconnect<br />

Devices<br />

Subfeed<br />

Circuit<br />

Breakers <br />

Enclosure<br />

Heights<br />

Inches – (mm)<br />

Standard<br />

Trims<br />

BL, BLH, HBL, BQD, BL, BLH, HBL, BQD, BQD6 , QJ2 ,<br />

BQD6 , BLE, BLEH, QJH2 , QJ2H , QR2 , QRH2 ,<br />

BLF2, BLHF2, HBLF2, HQR2 , HQR2H , ED4, HED4,<br />

BLFB, BLHFB, BAF2, HHED6, ED6, BLE, BLEH, BLF2,<br />

BAFH2, HBAF2, BGL, BLHF2, HBLF2, BLFB, BLHFB, BAF2,<br />

NGB , HGB , LGB BAFH2, HBAF2, BGL, NGB, HGB,<br />

LGB, NGB2, HGB2, LGB2<br />

ED4, ED6, HED4, HHED6,<br />

QJ2, QJH2, QJ2H, QR2,<br />

QRH2, HQR2, HQR2H,<br />

FD6, HFD6, FXD6, HFXD6<br />

26, 32, 38, 44, 50, 56<br />

@250A (660, 813, 965,<br />

1118, 1270, 1422)<br />

56, 62, 68, 74 @400A<br />

(1422, 1575, 1727, 1880)<br />

Fas-Latch – 1 Piece<br />

Surface or Flush<br />

JD6, HJD6,<br />

JXD6, HJXD6,<br />

FD6, HFD6,<br />

FXD6, HFXD6<br />

26, 32, 38, 44, 50, 56,<br />

62, 68, 74<br />

(660-1880)<br />

Fas-Latch – 1 Piece<br />

Surface or Flush<br />

BL, BLH, HBL, BQD, BQD6 ,<br />

QJ2 , QJH2 , QJ2H , QR2 ,<br />

QRH2 , HQR2 , HQR2H ,<br />

ED4, HED4, HHED6, ED6,<br />

BLHF, BAF2, BAFH2, HBAF2,<br />

BGL, NGB, HGB, LGB, NGB2,<br />

HGB2, LGB2<br />

JD6, HJD6,<br />

JXD6,<br />

FD6, HFD6,<br />

FXD6, HFXD6<br />

56, 62, 68, 74, 80<br />

(1422-2032)<br />

Fas-Latch – 1 Piece<br />

Surface or Flush<br />

All 15-600A<br />

MCCBs,<br />

VL MG at 800A<br />

and 30-200A VB<br />

switches<br />

— —<br />

60, 75, 90<br />

(1524, 1905,<br />

2286)<br />

Four Piece <br />

Surface or Flush<br />

1-Phase, 3-wire<br />

3-Phase, 4-wire<br />

3-Phase, 3-wire<br />

800A-1200A<br />

800A-1200A<br />

200A-1200A<br />

15-1200A MCCB<br />

30-1200 Fusible<br />

All 15-1200A<br />

MCCBs, 30-600A<br />

VB switches and<br />

400-1200A HCP<br />

switches<br />

60, 75, 90<br />

(1524, 1905, 2286)<br />

Four Piece <br />

Surface or Flush<br />

Functional pricing is based on circuits shown. However, the<br />

panel can be figured with less circuits.<br />

P1 can have max. 1 subfeed breaker when Subfeed Space is<br />

available. P2 and P3 can have up to (2) FD subfeed breakers.<br />

JD and FD breakers are mounted vertical. Limitations apply.<br />

Trim ring provided for flush applications.<br />

A maximum of (4) QJ/QR breakers may be mounted<br />

in a P2 Panel and are single mounted.<br />

A maximum of (6) QJ/QR breakers may be mounted<br />

in a P3 panel and are twin mounted.<br />

P1 panels with xGB breakers are limited to xGB branch<br />

devices only. BL and BQD frames may not be mixed in<br />

this panel type.<br />

Factory assembled P1 has capability of 600Y/347V AC<br />

system when the proper breakers are selected.<br />

BQD6 is not UL Listed. Only for CUL and CSA panels.<br />

11-4<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Panelboards<br />

General Specifications<br />

Revised on 04/30/19<br />

General<br />

Typical Panelboard Modifications<br />

Description<br />

Box<br />

Type 1<br />

Lighting and Distribution Panelboards<br />

Distribution Panelboards<br />

P1 P2 P3 P4 P5<br />

Standard<br />

(20" W)<br />

Standard<br />

(20" W)<br />

Standard<br />

(24" W)<br />

Standard<br />

Standard<br />

Type 1 Enclosure with Hood ● ● ● ● ●<br />

Type 1 w/Gasket between box and front ● ● ● — —<br />

Type 2 Enclosure - Drip Tight (this is not available) — — — — —<br />

Type 3R/12 ● ● ● ● ●<br />

Type 4, 4X (size varies by type/material) ● ● ● ● ●<br />

Wider Box (check w/factory for custom options not shown) ● (24”W) ● (24”W) ● (custom) ● (custom) ● (custom)<br />

Deeper Box (check w/factory for custom options not shown) ● (7.75"D) ● (7.75”D) ● (custom) ● (custom) ● (custom)<br />

11 PANELBOARDS<br />

Front – NEMA Type 1 only<br />

Front with Door Standard Standard Standard ● ●<br />

4-piece Front — — — Standard Standard<br />

4-piece Front w/Hinged Gutter Covers — — — ● ●<br />

Hinged-to-Box Front/Screw-to-Box Front ● ● ● (see Door-in-Door) (see Door-in-Door)<br />

Door-in-Door Front ● ● ● ● ●<br />

Common Front (custom - multi section applications) ● (custom) ● (custom) ● (custom) — —<br />

Special Locks ● (custom) ● (custom) ● (custom) ● (custom) ● (custom)<br />

Nameplate (mounting provisions provided as Std - P1/P2/P3)<br />

- Nameplate text is configured in COMPAS with limitations.<br />

● ● ● ● ●<br />

Interior<br />

Aluminum Equipment Ground Bar Standard Standard Standard Standard Standard<br />

Copper Equipment Ground Bar ● ● ● ● ●<br />

Insulated Equipment Ground (CU or AL) ● ● ● ● ●<br />

Subfeed Lugs (see page 11-33 or 11-46) — ● ● ● ●<br />

Feed-Thru Lugs ● ● ● ● ●<br />

Split Bus — ● ● ● ●<br />

Compression Lugs ● ● ● ● ●<br />

Copper Lugs ● ● ● ● ●<br />

200% Neutral ● ● ● 400 - 600A 400 - 600A<br />

Temperature Rated - Aluminum1 Standard Standard Standard Standard Standard<br />

Temperature Rated - Copper 1 ● ● ● ● ●<br />

750 Ampere / in. - Aluminum — ● ● ● ●<br />

1000 Ampere / in. - Copper — ● ● ● ●<br />

Copper Plating<br />

Tin<br />

Tin Std./ Tin Std./<br />

Silver Opt. Silver Opt.<br />

Silver<br />

Silver<br />

Remote Control Switches<br />

External<br />

Mounted<br />

● ● ● ●<br />

Time Clocks<br />

External<br />

Mounted<br />

● ● ● ●<br />

Circuit Breaker Shunt Trips ● ● ● ● ●<br />

R, J and T Fuse Clips — — — ● ●<br />

All aluminum bus is tin-plated. ● Available as an option. — Not Available<br />

UL Fuse Classes a<br />

Interrupting<br />

Class Amperes Volts Ratings (kA) l 2 t, l i Circuits<br />

H 1-600 250 and 600V or less AC 10 — Less than 10,000A Available<br />

K5 b 1-600 250 and 600V or less AC 100 l•t – RK5 up to 100A, Feeder circuits<br />

l i – RK5 up to 100A<br />

J 1-600 600V or less 200 l•t – Low, l i – Low Feeder circuits (motor load small %)<br />

RK1 1/10-600 600V or less and 250V or less 200 l•t – Slightly > J, l i – Slightly > J Feeder circuits (motor load small %)<br />

RK5 1/10-600 600V or less and 250V or less 200 l•t – > RK-1, l i – > RK-1 Motor starting currents a factor<br />

T 1-800, 300 and 600V or less AC To 200 l•t – Low, l i – Low Non-Motor loads<br />

1-1200<br />

L 601-1200 600V or less 200 l•t – Low, l i – Low Mains, feeder circuits<br />

a Per UL 67.<br />

b Fuses do not prohibit the use of Class H type fuse in switch.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-5


Panelboards<br />

Trim / Front<br />

Revised on 04/30/19<br />

Dimensions<br />

11<br />

PANELBOARDS<br />

Standard Trim (FAS-Latch) Typical Dimensions<br />

(Hinges available as shown on right side only)<br />

(Typical 14 Gauge Steel construction or UL approved equivalent)<br />

Standard Trim (FAS-Latch)<br />

(14 Gauge Standard - no options)<br />

(UPB includes surface or flush versions<br />

of this style in chart on page 14. Other<br />

special fronts below may not be part of<br />

the UPB program.)<br />

Surface Flush<br />

Box Size A A<br />

# of<br />

Hinges<br />

26 26 27.5 2<br />

32 32 33.5 2<br />

38 38 39.5 2<br />

44 44 45.5 3<br />

50 50 51.5 3<br />

Surface Flush<br />

Box Size A A<br />

# of<br />

Hinges<br />

56 56 57.5 3<br />

62 62 63.5 3<br />

68 68 69.5 3<br />

74 74 75.5 3<br />

Material:<br />

• HRPO Steel painted ANSI 61 Light<br />

Grey is standard.<br />

• 304 Stainless available with limited<br />

piano hinge options.<br />

Also available<br />

• Screw to Box Trim<br />

(14 Gauge Std./12 Gauge & 10 Gauge<br />

Optional)<br />

• Piano Hinge Trim<br />

(14 Gauge Std./12 Gauge Optional)<br />

a) Screw to box with<br />

Piano Hinge Door<br />

b) Hinge to Box with Piano Hinge<br />

and Piano Hinge Door<br />

c) Door-in-Door with Piano Hinge,<br />

Both Doors<br />

Door in Door Front<br />

(14 Gauge Standard /12 Gauge<br />

& 10 Gauge optional)<br />

Hinged to Box Front<br />

(14 Gauge Standard /12 Gauge<br />

& 10 Gauge optional)<br />

11-6<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Panelboards<br />

Special Enclosures<br />

Revised on 05/01/17<br />

Options<br />

11 PANELBOARDS<br />

NEMA 3R/12 Enclosures<br />

(Sizes vary by construction)<br />

NEMA 4 Enclosures/<br />

NEMA 4X Enclosures<br />

(Sizes vary by construction)<br />

“P” Series Panelboard Family for Lighting and<br />

Appliance and Distribution Panel Applications<br />

Type 1 Front Styles available with material, lock and hinge options. d<br />

Push-In Panel Locks - Availability for Front/Door by Gauge c<br />

Note: Some Styles of fronts are not available in all Gauges shown (GA).<br />

Front/Door<br />

Thickness<br />

Replacement kit #<br />

(where available)<br />

and Reference<br />

Material #<br />

0.178 max (16-14 GA) Cat # LPLOCK01A a<br />

ref 11-1895-01<br />

0.208 max (12 GA) Cat # LPLOCK02A a<br />

ref 11-1895-02<br />

0.238 max (10 GA) Cat # LPLOCK03A a<br />

ref 11-1895-03<br />

This lock is<br />

Keyed For<br />

standard lock<br />

- keyed for B363A<br />

standard lock<br />

- keyed for B363A<br />

standard lock<br />

- keyed for B363A<br />

FAS-Latch (16<br />

Gauge)<br />

STB (Screw-to-Box)<br />

HTB (Hinged Front)<br />

DND (Door-in-Door)<br />

STB w/Piano Hinge<br />

Door<br />

HTB w/Piano Hinge<br />

2 places<br />

DND w/Piano Hinge<br />

2 places<br />

STB 304 Stainless<br />

w/Piano Hinge Door<br />

20" & 24" wide only<br />

HTB 304 Stainless<br />

w/Piano Hinge 2<br />

places 20" & 24"<br />

wide only<br />

std std std std std std std std std std<br />

n/a opt opt opt opt opt opt n/a n/a n/a<br />

n/a opt opt opt n/a n/a n/a n/a n/a n/a<br />

0.178 max (16-14 GA) Cat # tbd a ref tbd standard latch<br />

* * * * * * * * * *<br />

- no key provision<br />

Special Keyed Locks b below: (Contact Customer Support if needed)<br />

Front/Door Thickness Ref. Material Number b This lock is Keyed For e<br />

0.178 max (16-14 GA) 11-1896-01 Yale LL803 / GE 75<br />

(Corbin TEY)<br />

opt opt opt opt opt opt opt opt opt opt<br />

0.178 max (16-14 GA) 11-1896-02 Yale LL806 opt opt opt opt opt opt opt opt opt opt<br />

0.178 max (16-14 GA) 11-1896-03 Corbin TEU1 opt opt opt opt opt opt opt opt opt opt<br />

0.178 max (16-14 GA) 11-1896-04 Corbin CAT 60 opt opt opt opt opt opt opt opt opt opt<br />

0.178 max (16-14 GA) 11-1896-05 National C413A opt opt opt opt opt opt opt opt opt opt<br />

0.208 max (12 GA) 11-1896-06 Yale LL803 / GE 75 n/a opt opt opt opt opt opt n/a n/a n/a<br />

(Corbin TEY)<br />

0.208 max (12 GA) 11-1896-07 Yale LL806 n/a opt opt opt opt opt opt n/a n/a n/a<br />

0.208 max (12 GA) 11-1896-08 Corbin TEU1 n/a opt opt opt opt opt opt n/a n/a n/a<br />

0.208 max (12 GA) 11-1896-09 Corbin CAT 60 n/a opt opt opt opt opt opt n/a n/a n/a<br />

0.208 max (12 GA) 11-1896-10 National C413A n/a opt opt opt opt opt opt n/a n/a n/a<br />

0.238 max (10 GA) 11-1896-11 Yale LL803 / GE 75 n/a opt opt opt n/a n/a n/a n/a n/a n/a<br />

(Corbin TEY)<br />

0.238 max (10 GA) 11-1896-12 Yale LL806 n/a opt opt opt n/a n/a n/a n/a n/a n/a<br />

0.238 max (10 GA) 11-1896-13 Corbin TEU1 n/a opt opt opt n/a n/a n/a n/a n/a n/a<br />

0.238 max (10 GA) 11-1896-14 Corbin CAT 60 n/a opt opt opt n/a n/a n/a n/a n/a n/a<br />

0.238 max (10 GA) 11-1896-15 National C413A n/a opt opt opt n/a n/a n/a n/a n/a n/a<br />

DND 304 Stainless<br />

w/Piano Hinge 2<br />

places 20" & 24"<br />

wide only<br />

Comments<br />

be<br />

be<br />

be<br />

be<br />

be<br />

be<br />

be<br />

be<br />

be<br />

be<br />

be<br />

be<br />

be<br />

be<br />

be<br />

a Lock kits include one replacement lock with 2 keys<br />

#B363A<br />

b See Contact list below or Contact Customer Support<br />

for re-ordering special keyed locks as needed.<br />

c The lock options for Yale 511, BEST, Corbin 15751 and<br />

Corbin 15757 CANNOT be used in 12GA and 10GA<br />

fronts, or with any 304 Stainless Steel Fronts.<br />

d Factory has final determination on whether combinations<br />

of non-standard features are available. Contact<br />

Customer Support for complex front configurations.<br />

e The factory does not stock keys for these<br />

locks. It’s the customer’s responsibility to<br />

obtain it from outside sources. See contact<br />

info for special keys below.<br />

f Nema 3R/12, Nema4, Nema4X SS, Nema<br />

4X non-metallic Enclosures cannot be<br />

used with the fas-latch lock assy.<br />

g Consult Factory or Customer Support for<br />

any other special lock requirements.<br />

Contacts for Special Keys:<br />

National C413A Go to this website: http://compx.com/distcsp.html<br />

==> then lookup a distributor in<br />

your area to get keys. Or call 864-297-6655<br />

Corbin TEU1 or<br />

CAT 60<br />

Yale LL803 / GE<br />

75 (Corbin TEY)<br />

Contact your local distributor<br />

for special keys<br />

Contact your local distributor<br />

for special keys<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-7


Panelboards<br />

Features / Benefits<br />

Reference<br />

11<br />

PANELBOARDS<br />

The standard Siemens P1 panelboard has some unique features that make it easier to design for an engineer, easier to<br />

reconfigure in the field for a contractor, and easier to upgrade and maintain for the Owner. The P1 is the smallest panel in the<br />

Siemens lineup, with bus sizes up to 400A. What makes it different is the split neutral design and the open ended bus. In the<br />

Siemens panel, instead of the common single neutral bus on one end, we have a neutral bus on both sides that is cross-bussed.<br />

This makes branch wiring simpler and cleaner – the lead lengths for line and neutral can now be made nearly the same, creating<br />

more room and a neater installation. It also allows access to both ends of the bus as a standard feature – this provides the<br />

flexibility to make changes in the field, even if it wasn’t part of the original configuration. New Revised P1 introduced in 2015<br />

has extended circuits up to 66 available and also non-feed thru versions are available, without the Subfeed Space, in a 6'' smaller<br />

enclosure.<br />

MAIN BREAKER or SUB-FEED BREAKER<br />

MAIN LUGS or FEED-THROUGH LUGS<br />

INTEGRAL BUS MOUNTED SPD<br />

The following can be done to a standard P1 panelboard in the field with no modifications:<br />

b Change from top fed to bottom fed<br />

b Add feed-through lugs <br />

b Add an Integral bus-mounted SPD <br />

b Add a sub feed breaker up to 250 amps <br />

b Change from Main Lugs to Main Breaker<br />

b Change from Main Breaker to Main Lugs<br />

b Panel may have up to two ground assemblies. Options are: (a) standard aluminum, (b) optional copper, or (c) optional insulated/<br />

isolated aluminum or copper. Mounting provisions in opposing corners of the box are standard. Any of these options may be<br />

added after installation.<br />

Only when Subfeed Space is selected/available.<br />

11-8<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Panelboards<br />

Revised on 04/30/19<br />

Unassembled<br />

Reference<br />

Type P1 unassembled panelboards are<br />

completely convertible from main lug<br />

to main breaker and vice-versa.<br />

Additionally, feed-thru lugs up to 400<br />

ampere or subfeed circuit breakers up<br />

to 250 ampere can be added without<br />

increasing the box height for Revised<br />

P1 with “T” suffix, see the chart.<br />

1. When BL / BQD or GB Main Breaker<br />

is chosen as back-fed in unit space,<br />

the Main Breaker will use 2 or 3 positions<br />

of unit space and will reduce<br />

usable branch circuit space.<br />

2. List catalog number and price of<br />

interior, box and front.<br />

3. Select main lug kit or main breaker<br />

kit from appropriate tables.<br />

Note: Main/Subfeed Breaker<br />

mounting kits may be ordered with<br />

or without breakers included, see<br />

page 11-11 and 11-12 for selection.<br />

4. List required branch circuit<br />

breakers and filler plates to cover<br />

any unused positions.<br />

5. Select any modifications<br />

or accessories.<br />

11 PANELBOARDS<br />

Note: Revised P1 was introduced in 2015. All original P1 devices do not include the "Subfeed Space" Indicator.<br />

All original P1 included the Subfeed Space as standard.<br />

P 1 X 1 8 M C 2 5 0 A T<br />

Type of Panel<br />

P1<br />

Voltage and System<br />

X = 208Y/120, 3-Phase 4-Wire (C for Factory Assembled)<br />

A = 120/240V, 1-Phase 3-Wire<br />

E = 480Y/277V, 3-Phase 4-Wire<br />

7 = xGB interior, 480Y/277V, 3-Phase 4-Wire<br />

Circuits<br />

18, 30, 42, 54* (*Revised P1 only)<br />

Mains MC = Convertible mains<br />

Select Main Lug Kit or Breaker Mounting Kit from pages 11-11 or 11-12<br />

Amperage<br />

400A max (typically 250A or 400A) d<br />

Main Bus Material<br />

A = Aluminum<br />

C = Copper<br />

Subfeed Space Indicator (for Revised P1 only)<br />

T = Subfeed Space Included<br />

Note: Standard bussing in P1 panels is tin plated for aluminum and copper.<br />

Standard bus is temperature rated to the maximum amperage in the panel.<br />

Branch Breakers<br />

Panel Type Voltage (Max.) Breaker Type Additional Information<br />

P1, Revised P1 480 / 277 BQD, NGB, HGB, LGB,<br />

See Page 11-13<br />

240 BL, BLH, HBL, BQD, NGB, HGB, LGB<br />

600 / 347 BQDG , NGB, HGB, LGB<br />

a Consult sales office for availability of CSA.<br />

See <strong>Speedfax</strong> for additional information.<br />

600/347V options are not available in a UPB panel – see factory assembled section.<br />

d P1 panels use either 250A rated bus or 400A rated bus, regardless of the Main Breaker installed (or) MLO Amp rating chosen.<br />

Panels with 250A bus can have up to 250A Main Breaker or Main Lugs. Panels with 400A bus can have up to 400A Main Breaker or Main Lugs.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-9


Panelboards<br />

11<br />

PANELBOARDS<br />

Distributor Stock – Type P1 Panelboards<br />

Pricing An Unassembled Panel<br />

400A Max. — 20" Wide x 5.75" Deep<br />

1. Choose the appropriate Interior from the table<br />

below.<br />

2. Choose the Main Device: Main Lugs from<br />

page 11-11, Main Breaker Kit from pages 11-11<br />

to 11-12 and Main Breakers from Section 7.<br />

3. Choose Branch Breakers. BL, BQD and xGB<br />

breakers from Section 7.<br />

4. Choose Feed-Thru Lugs or Subfeed Breaker<br />

Kit from pages 11-11 to 11-12 and Subfeed<br />

Breaker from Section 7.<br />

Selection<br />

Type P1 Unassembled Panelboards (Revised P1 introduced 2014)<br />

Amps<br />

Max. #<br />

of Poles<br />

Original Interior<br />

Catalog Number<br />

Revised P1<br />

Interior<br />

Catalog Number<br />

Convertible Mains — 1-Phase, 3-Wire 120/240V<br />

a Front included in NEMA 3R and 3R/12 Box.<br />

The New Revised P1 (18 circuit 250A only) is limited to 100A<br />

per connection (200A per pair) when installing Branch Breakers<br />

Box<br />

Size<br />

Type 1<br />

Encl.<br />

Type 1<br />

Type 3R/12 Front<br />

Encl. Surface<br />

Type1<br />

Front<br />

Flush<br />

18 P1A18MC250A P1A18MC250AT 32 B32 WP32 S32B F32B<br />

250<br />

30 P1A30MC250A P1A30MC250AT 38 B38 WP38 S38B F38B<br />

42 P1A42MC250A P1A42MC250AT 44 B44 WP44 S44B F44B<br />

54 P1A54MC250AT 50 B50 WP50 S50B F50B<br />

18 P1A18MC400A — — — — — —<br />

400<br />

30 P1A30MC400A P1A30MC400AT 62 B62 WP62 S62B F62B<br />

42 P1A42MC400A P1A42MC400AT 68 B68 WP68 S68B F68B<br />

54 P1A54MC400AT 74 B74 WP74 S74B F74B<br />

18 P1A18MC250C P1A18MC250CT 32 B32 WP32 S32B F32B<br />

250<br />

30 P1A30MC250C P1A30MC250CT 38 B38 WP38 S38B F38B<br />

42 P1A42MC250C P1A42MC250CT 44 B44 WP44 S44B F44B<br />

54 P1A54MC250CT 50 B50 WP50 S50B F50B<br />

18 P1A18MC400C — — — — — —<br />

400<br />

30 P1A30MC400C P1A30MC400CT 62 B62 WP62 S62B F62B<br />

42 P1A42MC400C P1A42MC400CT 68 B68 WP68 S68B F68B<br />

54 P1A54MC400CT 74 B74 WP74 S74B F74B<br />

Convertible Mains — 3-Phase, 4-Wire 208Y/120V<br />

18 P1X18MC250A P1X18MC250AT 32 B32 WP32 S32B F32B<br />

250<br />

30 P1X30MC250A P1X30MC250AT 38 B38 WP38 S38B F38B<br />

42 P1X42MC250A P1X42MC250AT 44 B44 WP44 S44B F44B<br />

54 P1X54MC250AT 50 B50 WP50 S50B F50B<br />

18 P1X18MC400A — — — — — —<br />

400<br />

30 P1X30MC400A P1X30MC400AT 62 B62 WP62 S62B F62B<br />

42 P1X42MC400A P1X42MC400AT 68 B68 WP68 S68B F68B<br />

54 P1X54MC400AT 74 B74 WP74 S74B F74B<br />

18 P1X18MC250C P1X18MC250CT 32 B32 WP32 S32B F32B<br />

250<br />

30 P1X30MC250C P1X30MC250CT 38 B38 WP38 S38B F38B<br />

42 P1X42MC250C P1X42MC250CT 44 B44 WP44 S44B F44B<br />

54 P1X54MC250CT 50 B50 WP50 S50B F50B<br />

18 P1X18MC400C — — — — — —<br />

400<br />

30 P1X30MC400C P1X30MC400CT 62 B62 WP62 S62B F62B<br />

42 P1X42MC400C P1X42MC400CT 68 B68 WP68 S68B F68B<br />

54 P1X54MC400CT 74 B74 WP74 S74B F74B<br />

Convertible Mains — 3-Phase, 4-Wire 480Y/277V<br />

18 P1E18MC250A P1E18MC250AT 32 B32 WP32 S32B F32B<br />

250<br />

30 P1E30MC250A P1E30MC250AT 38 B38 WP38 S38B F38B<br />

42 P1E42MC250A P1E42MC250AT 44 B44 WP44 S44B F44B<br />

54 P1E54MC250AT 50 B50 WP50 S50B F50B<br />

18 P1E18MC400A — — — — — —<br />

400<br />

30 P1E30MC400A P1E30MC400AT 62 B62 WP62 S62B F62B<br />

42 P1E42MC400A P1E42MC400AT 68 B68 WP68 S68B F68B<br />

54 P1E54MC400AT 74 B74 WP74 S74B F74B<br />

18 P1E18MC250C P1E18MC250CT 32 B32 WP32 S32B F32B<br />

250<br />

30 P1E30MC250C P1E30MC250CT 38 B38 WP38 S38B F38B<br />

42 P1E42MC250C P1E42MC250CT 44 B44 WP44 S44B F44B<br />

54 P1E54MC250CT 50 B50 WP50 S50B F50B<br />

18 P1E18MC400C — — — — — —<br />

400<br />

30 P1E30MC400C P1E30MC400CT 62 B62 WP62 S62B F62B<br />

42 P1E42MC400C P1E42MC400CT 68 B68 WP68 S68B F68B<br />

54 P1E54MC400CT 74 B74 WP74 S74B F74B<br />

Interiors for xGB Breakers — 3-Phase, 4-Wire 480Y/277V<br />

18 P1718MC250A P1718MC250AT 32 B32 WP32 S32B F32B<br />

250<br />

30 P1730MC250A P1730MC250AT 38 B38 WP38 S38B F38B<br />

42 P1742MC250A P1742MC250AT 44 B44 WP44 S44B F44B<br />

54 P1754MC250AT 50 B50 WP50 S50B F50B<br />

18 P1718MC400A — — — — — —<br />

400<br />

30 P1730MC400A P1730MC400AT 62 B62 WP62 S62B F62B<br />

42 P1742MC400A P1742MC400AT 68 B68 WP68 S68B F68B<br />

54 P1754MC400AT 74 B74 WP74 S74B F74B<br />

18 P1718MC250C P1718MC250CT 32 B32 WP32 S32B F32B<br />

250<br />

30 P1730MC250C P1730MC250CT 38 B38 WP38 S38B F38B<br />

42 P1742MC250C P1742MC250CT 44 B44 WP44 S44B F44B<br />

54 P1754MC250CT 50 B50 WP50 S50B F50B<br />

18 P1718MC400C — — — — — —<br />

400<br />

30 P1730MC400C P1730MC400CT 62 B62 WP62 S62B F62B<br />

42 P1742MC400C P1742MC400CT 68 B68 WP68 S68B F68B<br />

54 P1754MC400CT 74 B74 WP74 S74B F74B<br />

across from one another. All other configurations allow 125A<br />

per connection max. (250A per pair max.)<br />

42 circuit with Back-fed Main<br />

54 circuit 400A<br />

11-10<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: UNPB


Panelboards<br />

Distributor Stock – Type P1 Panelboards<br />

Revised on 04/30/19<br />

Selection<br />

Lug Kits — Main or Feed Thru<br />

Amp<br />

Rating<br />

250<br />

400<br />

Mat.<br />

AL<br />

CU<br />

AL<br />

CU<br />

400 AL<br />

Wire Range<br />

(includes Neutral)<br />

(1) #6 AWG-<br />

350 kcmil (CU or AL)<br />

(1) #6 AWG-<br />

350 kcmil (CU)<br />

(2) 1/0 - 250 kcmil<br />

or (1) #2 AWG-600 kcmil<br />

(2) 1/0 - 4/0<br />

or (1) 1/0 - 600 kcmil<br />

(1) AL 1/0-750 kcmil<br />

(2) AL/CU 250kcmil max.<br />

[max.(1) 600 kcmil CU wire]<br />

Service<br />

Original P1<br />

Catalog No.<br />

Revised P1<br />

Catalog No.<br />

1 Phase MLKA1 MLKA1A<br />

3 Phase MLKA3 MLKA3A<br />

1 Phase MLKC1 MLKC1A<br />

3 Phase MLKC3 MLKC3A<br />

1 Phase 4MLKA1 4MLKA1A<br />

3 Phase 4MLKA3 4MLKA3A<br />

1 Phase 4MLKC1 4MLKC1A<br />

3 Phase 4MLKC3 4MLKC3A<br />

1 Phase – 4MLKA1B<br />

3 Phase – 4MLKA3B<br />

MBKQJ3A<br />

MBKFD3A<br />

11 PANELBOARDS<br />

Breaker Mounting Kits — Main or Subfeed w/o Breaker<br />

Ampere<br />

Rating Breaker Types Service<br />

Original P1<br />

Catalog No.<br />

Revised P1<br />

Catalog No. b<br />

100A BL, BLH, HBL 1-Phase MBKBL1 MBKBL1A<br />

3-Phase MBKBL3 MBKBL3A<br />

100A BQD<br />

—<br />

1-Phase<br />

125A NGB, HGB, LGB MBKNB1<br />

MBKBC1NBA<br />

100A BQD<br />

MBKBC3<br />

3-Phase<br />

125A NGB, HGB, LGB MBKNB3<br />

MBKBC3NBA<br />

125A ED4, ED6, HED4, HHED6 1-Phase MBKED1 MBKED1A<br />

3-Phase MBKED3 MBKED3A<br />

225A QJ2, QJH2, QJ2H 1-Phase MBKQJ1 MBKQJ1A<br />

3-Phase MBKQJ3 MBKQJ3A<br />

225A QR2, QRH2, HQR2, 1-Phase MBKQR1 MBKQR1A<br />

HQR2H<br />

3-Phase MBKQR3 MBKQR3A<br />

250A FXD6, FD6, HFD6, 1-Phase MBKFD1 MBKFD1A<br />

HFXD6<br />

3-Phase MBKFD3 MBKFD3A<br />

400A a JXD2, JD6, JXD6, 1-Phase MBKJD1 MBKJD1A<br />

HJD6, HJXD6<br />

3-Phase MBKJD3 MBKJD3A<br />

a400 amp kit is for main only — not allowed for subfeed breaker.<br />

MBKBFA kit is available to mount BL/BQD/xGB 2-pole or 3-pole in unit space as a "Back-Fed<br />

Main". This occupies branch space and reduces circuit count by 2 or 3 positions. (includes<br />

Neutral Lug, "MAIN" label and instructions).<br />

Although QR is rated 250A, it is limited to 225A in panelboard.<br />

Copper Neutral Lug Kits — 250A<br />

No.of<br />

Original P1 Revised P1<br />

Circuits Description<br />

Catalog No. Catalog No.<br />

18<br />

CNKL18 Use 30 ckt kit<br />

30 2 or 4 Branch Neutral Strips, CNKL30 CNLK30A<br />

42 1 Main Neutral Lug, Hardware CNKL42 CNLK42A<br />

54, 66 — CNLK54A<br />

2/0 Neutral Lug Kits — 250A and 400A<br />

18<br />

— Use 30 ckt kit<br />

30 2 or 4 Branch Neutral Strips, — LNLK30A<br />

42 Hardware<br />

— LNLK42A<br />

54, 66 — LNLK54A<br />

200% Neutral Lug Kits/250A<br />

18<br />

2NLK18 Use 30 ckt kit<br />

30 2 or 4 Branch Neutral Strips, 2NLK30 2NLK30A<br />

42 2 Main Neutral Lugs, Hardware 2NLK42 2NLK42A<br />

54, 66 — 2NLK54A<br />

200% Neutral Lug Kits/400A<br />

18<br />

42NLK18 Use 30 ckt kit<br />

30<br />

2 or 4 Branch Neutral Strips,<br />

42NLK30 42NLK30A<br />

1 Main 600MCM Neutral Lug,<br />

42<br />

Hardware<br />

42NLK42 42NLK42A<br />

54, 66 — 42NLK54A<br />

NOTES:<br />

a Original P1 kits will not work with Revised P1 interiors if the chart shows different part numbers for each.<br />

Revised P1 kits will not work with Original P1 interiors if the chart shows different part numbers for each.<br />

Field installable Service Entrance Barrier kits are now available as required by UL67 (In COMPAS, you<br />

must select Service Entrance Required).<br />

Miscellaneous Parts and Accessories<br />

Catalog # Description<br />

BK1<br />

Bonding Kit for 400A max. Original P1 Panels<br />

BK1A<br />

Bonding Kit for 400A max. Revised P1 Panels<br />

BK2 Bonding kit for S1/S2 400 & 600<br />

BK3<br />

Bonding kit for S3 Panel<br />

IMK1<br />

Interior Adjusting Kit<br />

LPDC01 Directory Card (Pack of 10; ref. 12-1110-01)<br />

LPDC02 Directory Card Holder (Pack of 10; ref. 11-1824-01)<br />

MCHK<br />

Metal Card Holder Kit<br />

NBK03<br />

Number Strips 1–42. Stick-on type (P1 Panels only)<br />

NBK04<br />

Number Strips 43–84. Stick-on type (P1 Panels only)<br />

NBK05<br />

Number Strips 85–126. Stick-on type (P1 Panels only)<br />

NBK06<br />

Number Strips 127–168. Stick-on type (P1 Panels only)<br />

EGK<br />

AL Ground Bus 44 Connections<br />

ECGK<br />

CU Ground Bus 44 Connections<br />

IGK<br />

Insulated AL Ground Bus<br />

ICGK<br />

Insulated CU Ground Bus<br />

SEBKRP1V1 c FD, QJ, QR Service Entrance Barrier Kit (Revised P1)<br />

SEBKRP1V2 c ED Service Entrance Barrier Kit (Revised P1)<br />

SEBKRP1V3 c BL/BQD Service Entrance Barrier Kit (Revised P1) back-fed<br />

SEBKRP1V4 c xGB Service Entrance Barrier Kit (Revised P1) back-fed<br />

SEBKRP1V5 c BL/BQD/xGB Service Entrance Barrier Kit (RP1 in main<br />

space)<br />

SEBKP1P2P3V1 c JD, LD Service Entrance Barrier Kit (RP1, P1, P2, P3)<br />

EWK1<br />

End Wall Kit with Knockouts (20" W x 5.75" DP)<br />

EWK2<br />

End Wall Kit with Knockouts (24" W x 7.75" DP)<br />

EBF1<br />

NEB/HEB Filler Plate<br />

P1SCRWS Package of 42 breaker mounting screws for P1<br />

1" Branch circuit filler plate (used for BL/BQD/xGB/<br />

DFFP1<br />

xGB2/ED blank positions) (suitable for replacing QF3<br />

in P1 thru P5 Panelboards and Switchboards)<br />

P1CONBPHCU Connector kit – 6 pcs. B-phase Copper<br />

P1CONBPHAL Connector kit – 6 pcs. B-phase Aluminum<br />

P1CONACPHCU d Connector kit – 6 pcs. A or C-phase Copper<br />

MBKQRFK<br />

P1/Revised P1 Filler for 1PH/3PH QR. Horizontal<br />

mount only.<br />

ANSI/NEMA General Instructions for Proper Installation,<br />

Operation, and Maintenance of Panelboards Rated<br />

PB 1.1-2013<br />

600 Volts or Less (O&M Manual) <br />

a Replacement parts only.<br />

PDF can be downloaded (at no cost) and printed at this location:<br />

www.nema.org/standards/pages/Panelboards.aspx (ref. Material #11-1056-01)<br />

c Factory installed and Field installable Service Entrance Barrier kits are now available<br />

as required by UL67. (In COMPAS, you must select Service Entrance Required.)<br />

d Use for both CU and AL bus interiors.<br />

Product Category UNPB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-11


Panelboards<br />

Warehouse Stock/Unassembled – Type P1 Panelboards<br />

Revised on 04/30/19<br />

Selection<br />

11<br />

PANELBOARDS<br />

Main Breaker Mounting Kits with Breakers for P1 Panels<br />

(250A and lower can be used as subfeed kits also)<br />

Original P1 Catalog No.<br />

(QJ/QR type listed where<br />

applicable)<br />

Revised P1 Catalog No.<br />

(QJ/QR type listed where<br />

applicable)<br />

Description<br />

Ratings<br />

MBKED3100 MBKED3100A Kit w/3-pole ED4 100A breaker 65KA 18KA<br />

MBKED3125 MBKED3125A Kit w/3-pole ED4 125A breaker 65KA 18KA<br />

MBKQR1 plus breaker MBKQR1125A Kit w/2-pole QR2 125A breaker 10KA —<br />

MBKQR1 plus breaker MBKQR1150A Kit w/2-pole QR2 150A breaker 10KA —<br />

MBKQR1 plus breaker MBKQR1175A Kit w/2-pole QR2 175A breaker 10KA —<br />

MBKQR1 plus breaker MBKQR1200A Kit w/2-pole QR2 200A breaker 10KA —<br />

MBKQR1 plus breaker MBKQR1225A Kit w/2-pole QR2 225A breaker 10KA —<br />

MBKQR3 plus breaker MBKQR3125A Kit w/3-pole QR2 125A breaker 10KA —<br />

MBKQR3 plus breaker MBKQR3150A Kit w/3-pole QR2 150A breaker 10KA —<br />

MBKQR3 plus breaker MBKQR3175A Kit w/3-pole QR2 175A breaker 10KA —<br />

MBKQR3 plus breaker MBKQR3200A Kit w/3-pole QR2 200A breaker 10KA —<br />

MBKQR3 plus breaker MBKQR3225A Kit w/3-pole QR2 225A breaker 10KA —<br />

MBKQR1 plus breaker MBKQR1125HA Kit w/2-pole HQR2 125A breaker 65KA —<br />

MBKQR1 plus breaker MBKQR1150HA Kit w/2-pole HQR2 150A breaker 65KA —<br />

MBKQR1 plus breaker MBKQR1175HA Kit w/2-pole HQR2 175A breaker 65KA —<br />

MBKQR1 plus breaker MBKQR1200HA Kit w/2-pole HQR2 200A breaker 65KA —<br />

MBKQR1 plus breaker MBKQR1225HA Kit w/2-pole HQR2 225A breaker 65KA —<br />

MBKQR3 plus breaker MBKQR3125HA Kit w/3-pole HQR2 125A breaker 65KA —<br />

MBKQR3 plus breaker MBKQR3150HA Kit w/3-pole HQR2 150A breaker 65KA —<br />

MBKQR3 plus breaker MBKQR3175HA Kit w/3-pole HQR2 175A breaker 65KA —<br />

MBKQR3 plus breaker MBKQR3200HA Kit w/3-pole HQR2 200A breaker 65KA —<br />

MBKQR3 plus breaker MBKQR3225HA Kit w/3-pole HQR2 225A breaker 65KA —<br />

MBKFD3150 MBKFD3150A Kit w/3-pole FXD6 150A breaker 65KA 35KA<br />

MBKFD3175 MBKFD3175A Kit w/3-pole FXD6 175A breaker 65KA 35KA<br />

MBKFD3200 MBKFD3200A Kit w/3-pole FXD6 200A breaker 65KA 35KA<br />

MBKFD3225 MBKFD3225A Kit w/3-pole FXD6 225A breaker 65KA 35KA<br />

MBKFD3250 MBKFD3250A Kit w/3-pole FXD6 250A breaker 65KA 35KA<br />

MBKJD1300 MBKJD1300A Kit w/2-pole JXD6 300A breaker 65KA 35KA<br />

MBKJD3300 MBKJD3300A Kit w/3-pole JXD6 300A breaker 65KA 35KA<br />

MBKJD1400 MBKJD1400A Kit w/2-pole JXD6 400A breaker 65KA 35KA<br />

MBKJD3400 MBKJD3400A Kit w/3-pole JXD6 400A breaker 65KA 35KA<br />

MBKJD12300 MBKJD12300A Kit w/2-pole JXD2 300A breaker 65KA –<br />

MBKJD32300 MBKJD32300A Kit w/3-pole JXD2 300A breaker 65KA –<br />

MBKJD12400 MBKJD12400A Kit w/2-pole JXD2 400A breaker 65KA –<br />

MBKJD32400 MBKJD32400A Kit w/3-pole JXD2 400A breaker 65KA –<br />

240V<br />

480V<br />

Branch Breakers<br />

Selection for P1<br />

a Kits are for Main only. New “Revised P1” kits can be used for either top feed or bottom feed.<br />

NOTE: "Revised P1" Kits above only work for interior numbers ending in "T" or "N". Use "Original P1" kits for all others.<br />

Selection Guide<br />

1. Select breaker type.<br />

2. Select required<br />

amperage.<br />

3. Select number of<br />

poles.<br />

4. Select branch breaker<br />

catalog numbers.<br />

5. Select ground bar and<br />

filler plates.<br />

(See replacement<br />

parts & accessories<br />

on Page 11-11.)<br />

300A Main installed.<br />

These Revised P1 kits<br />

can now be used as top<br />

or bottom feed.<br />

11-12<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category UNPB


Panelboards<br />

Warehouse Stock/Unassembled<br />

Revised on 04/30/19<br />

Selection<br />

Branch Breakers Selection for P1<br />

BL Family Circuit Breakers<br />

Amp<br />

1-Pole 2-Pole 3-Pole<br />

Ratings 120V 240/120V 240V 240V<br />

Type BL - 10,000A IR a<br />

15 B115 B215 B215R B315<br />

20 B120 B220 B220R B320<br />

25 B125 B225 B225R B325<br />

30 B130 B230 B230R B330<br />

35 B135 B235 B235R B335<br />

40 B140 B240 B240R B340<br />

45 B145 B245 B245R B345<br />

50 B150 B250 B250R B350<br />

55 B155 — — —<br />

60 B160 B260 — B360<br />

70 B170 B270 — B370<br />

80 — B280 — B380<br />

90 — B290 — B390<br />

100 — B2100 — B3100<br />

Type BLH — 22,000 IR a<br />

15 B115H B215H — B315H<br />

20 B120H B220H — B320H<br />

25 B125H B225H — B325H<br />

30 B130H B230H — B330H<br />

35 B135H B235H — B335H<br />

40 B140H B240H — B340H<br />

45 B145H B245H — B345H<br />

50 B150H B250H — B350H<br />

55 B155H — — —<br />

60 B160H B260H — B360H<br />

70 B170H B270H — B370H<br />

80 — B280H — B380H<br />

90 — B290H — B390H<br />

100 — B2100H — B3100H<br />

Type HBL — 65,000A IR a<br />

15 B115HH B215HH — B315HH<br />

20 B120HH B220HH — B320HH<br />

30 B130HH B230HH — B330HH<br />

40 B140HH B240HH — B340HH<br />

50 B150HH B250HH — B350HH<br />

60 — B260HH — B360HH<br />

70 — B270HH — B370HH<br />

80 — B280HH — B380HH<br />

90 — B290HH — B390HH<br />

100 — B2100HH — B3100HH<br />

BQD & GB Family Circuit Breakers<br />

Amp 1-Pole 2-Pole 3-Pole<br />

Ratings 277V 480Y/277V 480Y/277V<br />

Type BQD b – 14,000A IR @ 480/277V | 65,000A IR @ 240V<br />

15 BQD115 BQD215 BQD315<br />

20 BQD120 BQD220 BQD320<br />

25 BQD125 BQD225 BQD325<br />

30 BQD130 BQD230 BQD330<br />

35 BQD135 BQD235 BQD335<br />

40 BQD140 BQD240 BQD340<br />

45 BQD145 BQD245 BQD345<br />

50 BQD150 BQD250 BQD350<br />

55 BQD155 BQD255 BQD355<br />

60 BQD160 BQD260 BQD360<br />

70 BQD170 BQD270 BQD370<br />

80 BQD180 BQD280 BQD380<br />

90 BQD190 BQD290 BQD390<br />

100 BQD1100 BQD2100 BQD3100<br />

GB Family b<br />

Type NGB - 25,000A IR @ 480/277V | 100,000A IR @ 240V<br />

Type HGB - 35,000A IR @ 480/277V | 100,000A IR @ 240V<br />

Type LGB - 65,000A IR @ 480/277V | 100,000A IR @ 240V<br />

Type NGB/HGB/LGB - 14,000A IR @ 347V and 600Y/347V<br />

Amp<br />

Ratings 277V 480Y/277V 480Y/277V<br />

15 xGB1B015B xGB2B015B xGB3B015B<br />

20 xGB1B020B xGB2B020B xGB3B020B<br />

25 xGB1B025B xGB2B025B xGB3B025B<br />

30 xGB1B030B xGB2B030B xGB3B030B<br />

35 xGB1B035B xGB2B035B xGB3B035B<br />

40 xGB1B040B xGB2B040B xGB3B040B<br />

45 xGB1B045B xGB2B045B xGB3B045B<br />

50 xGB1B050B xGB2B050B xGB3B050B<br />

60 xGB1B060B xGB2B060B xGB3B060B<br />

70 xGB1B070B xGB2B070B xGB3B070B<br />

80 xGB1B080B xGB2B080B xGB3B080B<br />

90 xGB1B090B xGB2B090B xGB3B090B<br />

100 xGB1B100B xGB2B100B xGB3B100B<br />

110 xGB1B110B xGB2B110B xGB3B110B<br />

125 xGB1B125B xGB2B125B xGB3B125B<br />

Typical Cable Ranges by Breaker Type<br />

UL Breaker<br />

Type<br />

BL<br />

BQD<br />

xGB<br />

Amps<br />

Connector Range<br />

for AL cable<br />

Connector Range<br />

for CU cable<br />

15-20A #12-#10 AWG #14-#10 AWG<br />

25-35A #8-#6 AWG #8-#6 AWG<br />

10-50A #8-#4 AWG #8-#6 AWG<br />

55-70A #8-#2 AWG #8-#4 AWG<br />

80-100A #2-#1/0 AWG #4-#1/0 AWG<br />

15-40A #12-#6 AWG #14-#6 AWG<br />

45-100A #6-1/0 AWG #8 - #1 AWG<br />

15-30A #12-#6 AWG #14-#6 AWG<br />

35-125A #4-2/0 AWG #6-1/0 AWG<br />

11 PANELBOARDS<br />

a To add Shunt trip to BL breakers (factory assempled<br />

only), See SpeedFax Breaker accessories section 7.<br />

One inch additional unit space required typically.<br />

b To add Shunt trip or other accessories to BQD and GB<br />

family breakers, See SpeedFax Breaker accessories<br />

section 7. One inch additional unit space required<br />

typically for each.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-13


Panelboards<br />

Warehouse Stock/Unassembled<br />

Revised on 04/30/19<br />

Selection<br />

11<br />

PANELBOARDS<br />

AFCI/GFCI<br />

Electronic<br />

Circuit Breakers<br />

Trip<br />

Type<br />

Combination<br />

AFCI<br />

Dual Function<br />

AFCI/GFCI<br />

Switching<br />

Neutrals1<br />

GFCI<br />

Personnel<br />

Protection<br />

(5mA)<br />

GFCI<br />

Ground<br />

Fault<br />

Equipment<br />

Protection<br />

(30mA)<br />

Breaker<br />

Type<br />

1-Pole<br />

Max IR (kA) at<br />

Amp Ratings<br />

120V Available<br />

2-Pole<br />

Max IR (kA) at<br />

120/<br />

240V<br />

Amp Ratings<br />

Available<br />

Catalog<br />

Number<br />

BAF2 10 15 — — BA115AFC<br />

10 20 — — BA120AFC<br />

BAFH2 22 15 — — BA115AFCH<br />

22 20 — — BA120AFCH<br />

HBAF2 65 15 — — BA115AFCHH<br />

65 20 — — BA120AFCHH<br />

BAF — — 10 15 B215AFC<br />

— — 10 20 B220AFC<br />

BAFH — — 22 15 B215AFCH<br />

— — 22 20 B220AFCH<br />

BFGA2 10 15 — — B115DF<br />

10 20 — — B120DF<br />

BFGAH2 22 15 — — B115DFH<br />

22 20 — — B120DFH<br />

HBFGA2 65 15 — — B115DFHH<br />

65 20 — — B120DFHH<br />

BLG<br />

2-Wire/3-Wire<br />

Common Trip<br />

10 15 — — BG215<br />

10 20 — — BG220<br />

— — 10 30 BG330<br />

BLF2 10 15 — — BF115A<br />

10 20 — — BF120A<br />

10 30 — — BF130A<br />

BLF — — 10 15 BF215A<br />

— — 10 20 BF220A<br />

— — 10 30 BF230A<br />

— — 10 40 BF240A<br />

— — 10 50 BF250A<br />

— — 10 60 BF260A<br />

BLHF2 22 15 — — BF115AH<br />

22 20 — — BF120AH<br />

22 30 — — BF130AH<br />

BLHF — — 22 15 BF215AH<br />

— — 22 20 BF220AH<br />

— — 22 30 BF230AH<br />

— — 22 40 BF240AH<br />

— — 22 50 BF250AH<br />

— — 22 60 BF260AH<br />

HBLF2 65 15 — — BF115AHH<br />

65 20 — — BF120AHH<br />

65 30 — — BF130AHH<br />

BLE 10 15 — — BE1153<br />

10 20 — — BE1203<br />

10 30 — — BE130<br />

— — 10 15 BE215<br />

— — 10 20 BE220<br />

— — 10 30 BE230<br />

— — 10 40 BE240<br />

— — 10 50 BE250<br />

— — 10 60 BE260<br />

BLEH 22 15 — — BE115H2<br />

22 20 — — BE120H2<br />

22 30 — — BE130H2<br />

— — 22 15 BE215H2<br />

— — 22 20 BE220H2<br />

— — 22 30 BE230H2<br />

— — 22 40 BE240H2<br />

— — 22 50 BE250H2<br />

— — 22 60 BE260H2<br />

a Built to order. Additional "circuit" is included for neutral<br />

(via pigtail) and is NOT connected to bus. 2-pole is one<br />

phase and one neutral pigtail. 3-pole is two phase<br />

connections and one neutral pigtail.<br />

b Allow 8-10 weeks for delivery<br />

c UL Listed as SWD (Switching Duty) Rated, suitable for<br />

120V AC fluorescent lighting<br />

11-14<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Panelboards<br />

Panelboard Replacement, Modification, and Additions<br />

Revised on 04/30/19<br />

Selection<br />

S1/S2 Panels—All the original P1 panel kits for 250 amp and<br />

below panels will work for 250 amp maximum S1/S2 panels<br />

(will not work for S1/S2 400A and above).<br />

Note: Revised P1 kits will not work with S1/S2 or SE Panels.<br />

400/600 Amp S1/S2 and All SE Panels<br />

Lug Kits — Main or Feed Thru<br />

Ampere<br />

Catalog<br />

Rating Material Wire Range Service Number<br />

125A/250A Al/Cu (2) 1/0–250 kcmil 1-Phase MLKA1<br />

125A/250A Al/Cu (2) 1/0–250 kcmil 3-Phase MLKA3<br />

400A/600A<br />

400A/600A<br />

Al/Cu<br />

Al/Cu<br />

(2) #4–250 kcmil or<br />

(1) 3/0–500 kcmil<br />

(2) #4–250 kcmil or<br />

(1) 3/0–500 kcmil<br />

1-Phase<br />

3-Phase<br />

SMLKA1<br />

SMLKA3<br />

Other applications:<br />

For P4/S4 and 10" deep SPP panels see page 11-77 for branch breaker mounting kits.<br />

For P5/S5 and 12.75" deep SPP panels see page 11-91 for branch breaker mounting kits.<br />

For P4/F1 and 10" deep FPP panels see page 11-77 for branch fusible switch mounting kits.<br />

For P5/F2 and 12.75" deep FPP panels see page 11-91 for branch fusible switch mounting kits.<br />

For Series 5, Series 6, CDP6 and VB 6 panels as well as FC20, FCI, FCII, SB1, SB2 and SB3<br />

distribution switchboards, see page 12-32 for branch device mounting kits.<br />

Filler Plate Replacement Kits for Lighting Panels<br />

Ref.<br />

A<br />

B<br />

C<br />

D<br />

E<br />

F<br />

G<br />

Panel Type<br />

P1 & RP1,<br />

P2, P3, C1, C2<br />

P1 & RP1, C1<br />

P1 & RP1<br />

P1 & RP1<br />

P1 & RP1<br />

P1 & RP1<br />

P1 & RP1<br />

Breaker<br />

Position Breaker Type Orientation Catalog No. Description<br />

Branch &<br />

Main<br />

Main /<br />

Subfeed<br />

Main /<br />

Subfeed<br />

Main /<br />

Subfeed<br />

Main /<br />

Subfeed<br />

Main /<br />

Subfeed<br />

Main /<br />

Subfeed<br />

BL/BQD/xGB/<br />

xGB2/ED<br />

Horizontal or Vertical<br />

(as needed)<br />

Neutral Kits<br />

Ampere<br />

Catalog<br />

Rating Description Number<br />

250A max. 30/42 circuit 200% neutral kit 2NLK2<br />

400/600A max. 42 circuit 200% neutral kit 2NLK1<br />

Breaker Mounting Kits (Main or Subfeed)<br />

Ampere<br />

Catalog<br />

Rating Breaker Types Service Number<br />

125A ED2, ED4, ED6, HED4, HHED6 1-Phase SMBKED1<br />

125A ED2, ED4, ED6, HED4, HHED6 3-Phase SMBKED3<br />

250A FXD6, FD6, HFXD6, HFD6 1-Phase SMBKFD1<br />

250A FXD6, FD6, HFXD6, HFD6 3-Phase SMBKFD3<br />

400A JD6, JXD6, HJD6, HJXD6 1-Phase SMBKJD1<br />

400A JD6, JXD6, HJD6, HJXD6 3-Phase SMBKJD3<br />

600A LD6, LXD6, HLD6, HLXD6 1-Phase SMBKLD1<br />

600A LD6, LXD6, HLD6, HLXD6 3-Phase SMBKLD3<br />

DFFP1 Blank Filler 1"<br />

blank - no breaker Horizontal or Vertical DFFP01A P1 Blank Filler Plate<br />

ED Horizontal DFFPED01 P1 125A Filler Plate<br />

QJ 2-pole Horizontal DFFPQJ02 P1 QJ Filler Plate<br />

QJ 3-pole Horizontal DFFPQJ01 P1 QJ Filler Plate<br />

QR Horizontal MBKQRFK P1 QR Filler Plate<br />

FD Horizontal DFFPFD01 FD Filler Plate<br />

H P1 & RP1 Main JD Vertical DFFPJD01 Deadfront Filler 400A Breaker<br />

I P2 & P3 Branch<br />

BL/BQD/xGB/<br />

xGB2/ED<br />

n/a<br />

DFK1<br />

J P2 & P3 Branch blank - no breaker Horizontal DFFP3<br />

K P2 & P3 Branch blank - no breaker Horizontal DFFP6<br />

L P2 Branch QR Horizontal and Vertical BBKQRP1FK<br />

M P3 Branch QR Horizontal BBKQRP2FK<br />

N P3 Branch NEB/HEB Horizontal EBF1 EB Deadfront Filler<br />

O P3 Branch<br />

BL, BQD,<br />

ED or GB<br />

Horizontal<br />

DFP3AP01<br />

Center strips included (7 sizes)<br />

3", 6", 9", 12", 15", 18", 21" (of branch height)<br />

P2 Blank Deadfront Plate 3"<br />

P3 Blank Cover Plate 2.97"<br />

P2 Blank Deadfront Plate 6"<br />

P3 Blank Cover Plate 5.97"<br />

QR Deadfront Plate<br />

P1 QR Filler Plate<br />

P2 QR Filler Plate<br />

P3 QR Deadfront Filler<br />

P3 DUAL QJ Deadfront Plate<br />

P3 DUAL QJ Deadfront Plate (1-Phase & 3-Phase)<br />

P3 QR-QJ Combo Deadfront Plate<br />

Breaker Blank Filler<br />

P3 BL/BQD/ED/xGB adaptor<br />

plate 3" - 1 Piece per pack<br />

11 PANELBOARDS<br />

Product Category UNPB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-15


Panelboards<br />

Factory Assembled<br />

Revised on 05/15/18<br />

Selection<br />

11<br />

Catalog Numbering System<br />

P 1 C 4 2 F X 2 5 0 A T S T<br />

PANELBOARDS<br />

Type of Panel P1, P2, P3, P4, P5<br />

Voltage and System*<br />

C = 208Y/120 3Ø 4 W Wye AC - All (X for UPB) R = 415/240 3Ø 4 W Wye AC - All<br />

E = 480Y/277 3Ø 4 W Wye AC - All<br />

S = 440/250 3Ø 4 W Wye AC - All<br />

D = 240 3Ø 3 W Delta AC - All<br />

L = 600/347 3Ø 4 W Wye AC - All<br />

F = 480 3Ø 3 W Delta AC - P2, P3, P4, P5<br />

T = 230 3Ø 3 W Delta AC - All<br />

G = 600 3Ø 3 W Delta AC - P2, P3, P4, P5<br />

W = 380 3Ø 3 W Delta AC - P2, P3, P4, P5<br />

I = 347 3Ø 3 W Delta AC P2, P3, P4, P5<br />

1 = 24V DC 1-Pole Branch Only - P2, P3, P4, P5<br />

B = 240/120 3Ø 4 W Delta BØ High Leg AC - P2, P3, P4, P5 2 = 24V DC 2-Pole Branch Only - P2, P3, P4, P5<br />

Q = 240/120 3Ø 4 W Delta CØ High Leg AC - P2, P3, P4, P5 3 = 48V DC 1-Pole Branch Only - P2, P3, P4, P5<br />

A = 120/240 1Ø 3 W Grounded Neutral AC - All 4 = 48V DC 2-Pole Branch Only - P2, P3, P4, P5<br />

H = 120 1Ø 2 W Grounded Neutral AC - P2, P3, P4, P5 5 = 125V DC 1-Pole Branch Only - P2, P3, P4, P5<br />

J = 240 1Ø 2 W No Neutral AC - All<br />

N = 125V DC 2-Pole Branch Only - P2, P3, P4, P5<br />

Y = 125 1Ø 2 W Grounded Neutral AC - P2, P3, P4, P5 O = 125/250V DC 2-Pole Branch Only - P2, P3, P4, P5<br />

Z = No Longer Available<br />

P = 125/250V DC 2 & 3-Pole Branch - P2, P3, P4, P5<br />

K = 220/127 3Ø 4 W Wye AC - All<br />

U = 120V AC 3Ø3W - All<br />

M = 380/220 3Ø 4 W Wye AC - All<br />

V = 240V 3Ø3W Grounded B Phase - P2, P3, P4, P5<br />

*For any voltage system not listed, check with sales for availability.<br />

Circuits or Enclosure Height <br />

P1 – 18, 30, 42, 54, 66<br />

P2 – 18, 30, 42, 54, 66, 78, 90<br />

P3 – 56, 62, 68, 74, 80<br />

P4, P5 – 60, 75, 90<br />

Main Lug (ML), Main Breaker<br />

(See Main Breaker Table coding below), Main Switch (MS)<br />

Amperage<br />

100–400A = P1 250 – 800A = P3<br />

100–600A = P2 400 –1200A = P4, P5<br />

Bus Bus Bus<br />

Code a Material Plating P1 P2 P3 P4 P5<br />

A Temp rated Al. Tin-Plated • • • • • • Indicates default<br />

B 750A/sq. in. Al. Tin-Plated n/a • • • • for this bus type.<br />

C Temp rated Cu. Tin-Plated • n/a n/a n/a n/a<br />

E Temp rated Cu. Silver-Plated n/a optional optional • •<br />

F Temp rated Cu. Tin-Plated n/a • • n/a n/a<br />

G 1000A/sq. in. Cu. Tin-Plated n/a • • optional optional<br />

H 1000A/sq. in. Cu. Silver-Plated n/a optional optional • •<br />

Feed Location T = Top B = Bottom<br />

Mounting<br />

S = Surface<br />

F = Flush. Flush trims extend 1 1/2" beyond the base box dimensions on P1, P2 and P3; and 2" on P4 and P5 panels.<br />

Subfeed Space Indicator (for P1 only) T = Subfeed Space Included N = No Subfeed Space<br />

Main Breaker Coding<br />

Breaker<br />

Code Type<br />

BL BL<br />

BH BLH<br />

BR BLR<br />

HB HBL<br />

BQ BQD<br />

B6 BQD6 c<br />

CE CED6<br />

E4 ED4<br />

E6 ED6<br />

H4 HED4<br />

HA HHED6<br />

CF CFD6<br />

FD FD6<br />

FX FXD6<br />

HF HFD6<br />

Breaker<br />

Code Type<br />

H2 HFXD6<br />

H1 HHFD6<br />

H3 HHFXD6<br />

G2 HGB<br />

G3 LGB<br />

NB NGB<br />

G4 NGB2<br />

G5 HGB2<br />

G6 LGB2<br />

CJ CJD6<br />

6H HHJD6<br />

H9 HHJXD6<br />

H6 HJD6<br />

H5 HJXD6<br />

H7 HJXD6H<br />

Breaker<br />

Code Type<br />

J6 JD6<br />

JD JXD2<br />

JX JXD6<br />

JH JXD6H<br />

SC SCJD6<br />

SX SHJD6<br />

SY SHJD6H<br />

SJ SJD6<br />

SH SJD6H<br />

CL CLD6<br />

HH HHLD6<br />

XH HHLXD6<br />

HL HLD6<br />

HO HLXD6<br />

HP HLXD6H<br />

a Standard bussing in P1, P2 and P3 panels is tin- plated<br />

for aluminum and copper. Standard bus is temperature<br />

rated to the maximum amperage in the panel.<br />

Breaker<br />

Code Type<br />

L6 LD6<br />

LX LXD6<br />

LH LXD6H<br />

S1 SCLD6<br />

S2 SHLD6<br />

SL SLD6<br />

QJ QJ2<br />

Q2 QJ2H<br />

QH QJH2<br />

C9 CMD6<br />

CH CMD6H<br />

HM HMD6<br />

HR HMXD6<br />

HS HMXD6H<br />

Breaker<br />

Code Type<br />

MD MD6<br />

MX MXD6<br />

MH MXD6H<br />

SO SCMD6<br />

SQ SCMD6H<br />

S5 SHMD6<br />

S6 SHMD6H<br />

SM SMD6<br />

AX SMD6H<br />

CN CND6<br />

C6 CND6H<br />

HN HND6<br />

HT HNXD6<br />

HX HNXD6H<br />

b Not available for Revised P1 xGB interiors.<br />

c BQD6 is not UL Listed. Only for CUL and CSA panels<br />

Breaker<br />

Code Type<br />

ND ND6<br />

NX NXD6<br />

NT NXD6H<br />

SR SCND6<br />

ST SCND6H<br />

AD SHND6<br />

SD SHND6H<br />

SN SND6<br />

AY SND6H<br />

J6 HJG<br />

J7 HJX<br />

J5 HJY<br />

J9 LJG<br />

J3 LJX<br />

J8 LJY<br />

Breaker<br />

Code Type<br />

L3 LLK<br />

J2 NJG<br />

J1 NJX<br />

J4 NJY<br />

L2 HLK<br />

L7 NLK<br />

M5 HMG<br />

M2 HMX<br />

M8 HMY<br />

M6 LMG<br />

M3 LMX<br />

M9 LMY<br />

M4 NMG<br />

M1 NMX<br />

M7 NMY<br />

Breaker<br />

Code Type<br />

N8 HNG<br />

N2 HNX<br />

N5 HNY<br />

N9 LNG<br />

N3 LNX<br />

N6 LNY<br />

N7 NNG<br />

N1 NNX<br />

N4 NNY<br />

QR QR2<br />

Q4 QRH2<br />

Q5 HQR2<br />

Q6 HQR2H<br />

Q7 QR2-MCS<br />

d P3, P4, P5 enclosure height tables found on page<br />

11-41, 11-70 and 11-85. These show the amount of<br />

unit space available.<br />

11-16<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Panelboards<br />

Revised on 05/01/17<br />

Circuit Breaker / Lighting and Distribution<br />

Pricing<br />

Type P1<br />

1) To specify a particular panelboard;<br />

list panel catalog number, branches,<br />

modifications, and price on an<br />

Estimate Sheet. Price includes interior<br />

with provisions, box, ground bar, and<br />

trim. See Example No. 1.<br />

2) When more than 66 circuits are<br />

specified for P1 a two section panel<br />

will be required. Feed-thru lugs must<br />

be priced in one section from the<br />

modifications on pages 11-24.<br />

Example No. 2 is a two section<br />

panel, each having 42 circuits.<br />

Section One will contain 1-225/3 QR2<br />

main breaker (top feed), 250A<br />

feed-thru lugs and 21" of unit space.<br />

Section Two will contain 250A main<br />

lugs only (bottom feed) and 21" of<br />

unit space. Sections will be 44"<br />

in height.<br />

3) Standard main breakers are indicated<br />

by the 6th and 7th positions in the<br />

catalog number. If any other main<br />

breaker type is required, replace with<br />

the appropriate code from page 11-16.<br />

See Example No. 3.<br />

4) All panel modifications must be listed<br />

and priced separately.<br />

5) If the boxes are to be sized the same<br />

then each panel must have the same<br />

amount of unit space.<br />

11 PANELBOARDS<br />

NOTE: This panel does not require Subfeed<br />

Space — indicated by "N" suffix<br />

Panel LPA<br />

1 — P1C30QR225ATSN 2540.<br />

10–20/1 25. ea. 250.<br />

4–30/3 140. ea. 560.<br />

3350.<br />

NOTE: This panel does includes Subfeed<br />

Space — indicated by "T" suffix<br />

Panel LPB<br />

1 — P1C42QR225ATST 2760.<br />

1 — P1C42ML250ATST 1330.<br />

1 — Feed-Thru Lugs 190.<br />

4280.<br />

NOTE: This panel does includes Subfeed<br />

Space — indicated by "T" suffix<br />

Panel LPC<br />

1 — P1C42HF250CTST 3160.<br />

HFD6 Main 1900.<br />

42–20/1 BLH 35. ea. 1470.<br />

Cu Bus 255.<br />

Type 3R 860.<br />

7645.<br />

Example No. 1 (pricing not current)<br />

Type P2<br />

Type P2 panelboards are priced the<br />

same as Type P1 described above except<br />

for two section panels.<br />

1) When more than 42 circuits are<br />

specified for P2, a two section panel<br />

will be assumed. Main breaker codes<br />

in the 5th and 6th positions will<br />

dictate the use of feed-thru lugs.<br />

An “ML” in the fifth and sixth<br />

positions will dictate the use of<br />

subfeed lugs for 125A and 250A and<br />

feed-thru lugs for 400A and 600A.<br />

Types P3, P4 and P5<br />

1) To specify a particular panelboard,<br />

first determine voltage, system,<br />

amperage and type of main,<br />

amperage and type of branch<br />

devices, and modifications if any.<br />

(Step 1)<br />

Step #1<br />

Amperage 400<br />

Voltage 208Y/120<br />

System 3-phase 4-wire<br />

Main<br />

Main Breaker<br />

Branches 5-125/3, 2-225/3,<br />

1-250/3<br />

Modification None<br />

Feed<br />

Top<br />

Mounting Surface<br />

Example No. 2 (pricing not current)<br />

Boxes will be sized the same for two<br />

section panels.<br />

Base price includes all provisions.<br />

Subfeed or feed-thru lugs as<br />

required must be priced separately.<br />

Example No. 4 is a two section<br />

panel, each having 42 circuits.<br />

Section One will contain 1-400/3<br />

JXD6 main breaker (top feed), 225A<br />

feed-thru lugs, and 21" of unit space.<br />

Section Two will contain 400A main<br />

2) List branch devices and<br />

modifications requiring space<br />

additions. List unit space<br />

requirements of each.<br />

Note: Some units are twin mounted<br />

meaning two breakers occupy the<br />

same unit space.<br />

Step #2<br />

Unit Space Calculation<br />

5-125/3 QR2 5" = 15"<br />

5-225/3 QR2 5" = 5"<br />

1-250/3 FXD6 5" = 5"<br />

25"<br />

Enclosure is B275 from Selection<br />

Chart on page 11-48.<br />

(32" wide, 75" high, 10" deep).<br />

Example No. 3 (pricing not current)<br />

lugs only (bottom feed) and 21" of<br />

unit space. Sections will be 53"<br />

in height.<br />

Select appropriate enclosure height<br />

from selection chart on pages 11-41,<br />

11-70, or 11-85, based on unit space<br />

requirements. (Step 2)<br />

3) Select panelboard catalog number<br />

from appropriate table based upon<br />

voltage, system, amperage and unit<br />

space requirements. (Step 3)<br />

Step #3<br />

1—P4C75JX400ATS $04210.<br />

5-125/3 QR2 940. 4700.<br />

2-225/3 QR2 940. 1880.<br />

1-250/3 FXD6 2700. 2700.<br />

13490.<br />

(pricing not current)<br />

For inches / millimeters conversion, see Application Data section.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-17


Panelboards<br />

Circuit Breaker / Lighting and Distribution<br />

Revised on 04/30/19<br />

General<br />

11<br />

PANELBOARDS<br />

Revised Type P1<br />

480Y/277 Vac Maximum<br />

600Y/ 347 Vac Maximum (limited<br />

applications)<br />

400 Ampere Mains<br />

400 Ampere Maximum Branch<br />

UL Short Circuit Rating —<br />

200,000 A. @ 240 Vac / 100,000 A. @<br />

480/277 Vac. IR Maximum<br />

Branch Breaker Symmetrical<br />

Interrupting Capacity<br />

Based on Underwriters’ Test Procedure<br />

Feed thru and subfeed lugs may result in<br />

lower interrupting ratings if not protected<br />

by a main device. Consult sales office.<br />

Meets 2014 NEC wire bending<br />

requirement, section 408.55.<br />

Meet Federal Specification W-P-115C.<br />

Panelboards<br />

Listed by Underwriters’ Laboratories,<br />

Inc., under ”Panelboards” File #E2269<br />

for interiors and #E4016 for boxes<br />

and fronts.<br />

Service<br />

1-phase 2-wire - 120 Vac, 240 Vac,<br />

1-phase 3-wire - 120/240 Vac,<br />

3-phase 3-wire - 480Y/277 (when derived<br />

from 3-phase 4-wire system), 240 Vac,<br />

120 Vac<br />

3-phase 4-wire - 208Y/120 Vac,<br />

480Y/277 Vac, 600Y/347 Vac,<br />

380/220 Vac.<br />

Panelboard Fronts and Doors<br />

Standard panelboards are furnished<br />

with trim featuring concealed fasteners<br />

and hinges with a flush door lock.<br />

All are factory-assembled for ease of<br />

installation. Fronts are fabricated from<br />

code gauge steel and finished ANSI-61.<br />

See page 11-6 for optional fronts.<br />

Main Breakers<br />

BL, BLH, HBL, NGB, HGB, LGB,<br />

BQD, ED4, ED6, HED4, QR2,<br />

QRH2,HQR2, HQR2H, FXD6, FD6,<br />

HFD6, HFXD6, JXD6, JD6,<br />

HJXD6, HJD6.<br />

(All main breakers except 400<br />

amp frame are mounted horizontal.)<br />

Note: Revised P1 interiors with<br />

BL, BQD or GB Type Mains can be<br />

Back-fed in unit space. See special<br />

Notes for unit space reduction.<br />

Main Breaker Panel Connectors<br />

Ampere<br />

Rating Connectors Suitable for Cu or Al<br />

100 (1)—#14 1/0 AWG<br />

125 (1)—#4 1/0 AWG<br />

225 (1)—#4 AWG–300 kcmil<br />

250<br />

(1)—#4/0 AWG–350 kcmil Al<br />

(1)—#6/0 AWG–350 kcmil Cu<br />

400a<br />

(2)—#3/0 AWG–250 kcmil Al or<br />

(1)—#3/0 AWG–500 kcmil Al<br />

Connector ranges indicated do not apply<br />

to all main breaker types. Refer to molded<br />

case circuit breaker standard pressure<br />

wire connector chart (Section 7) for the<br />

connector range of a specific frame.<br />

Main Lug Connectors<br />

125 (1)—#6 AWG–350 kcmil<br />

250 (1)—#6 AWG–350 kcmil<br />

400 std.<br />

AL (2) 110-250 kcmil or<br />

(1) #2 AWG–600 kcmil<br />

400 opt.<br />

400 opt.<br />

CU (2) 1/0–4/0 or<br />

(1) 110–600 kcmil<br />

AL (1) AL 1/0–750 kcmil<br />

(2) AL/CU 250 kcmil max.<br />

[max. (1) 600 kcmil (1) wire]<br />

Boxes<br />

20" wide, 5.75" deep<br />

b End walls are blank as standard.<br />

b End walls with knockouts will be<br />

supplied at no charge on 5.75" deep<br />

panels if requested at time of order.<br />

Main Breaker Gutter Dimensions<br />

(inches)<br />

Main<br />

Breaker<br />

Side<br />

Gutter<br />

20"<br />

w/box<br />

24"<br />

w/box<br />

Main Lug End Gutter Dimensions<br />

(inches)<br />

Amp End Neutral<br />

Rating Gutter Location<br />

125 10.500 11.500<br />

250 10.500 11.500<br />

400 c 25.500 26.750<br />

Neutral<br />

Location<br />

20"<br />

w/box<br />

BL, BLH, HBL 8.680 10.690 10.500<br />

BQD b 7.880 9.880 10.500<br />

NGB, LGB, HGB 7.770 9.770 10.500<br />

ED4, ED6, HED4 6.125 8.125 10.500<br />

QR2, QRH2, HQR2,<br />

HQR2H<br />

6.500 8.500 10.500<br />

FD6, FXD6, HFD6,<br />

HFDX6<br />

5.250 7.250 10.500<br />

JD6 b , JXD6 b 15.000 15.000 26.750<br />

Side Gutter Wiring Space (inches)<br />

Panel<br />

Reference Panel Width 24"<br />

Letter Width 20" (Optional)<br />

A 6.375 7.375<br />

B 5.500 7.500<br />

C 6.125 8.125<br />

D 6.500 8.500<br />

E d 5.250 7.250<br />

F 5.000 7.000<br />

Branch Breaker Side Gutters<br />

Weight — Approximate<br />

Total panelboard weight when filled with<br />

a normal quantity of breakers and<br />

accessories is:<br />

b About 3 lbs. per inch of box height<br />

Gauge Steel Boxes (Type 1)<br />

Width Height Gauge Steel<br />

20" All #16<br />

Fronts — Surface, Flush (Type 1)<br />

20" All #14<br />

Series Connected Short Circuit Ratings<br />

The term “Series Connected Short<br />

Circuit Rating” refers to the application<br />

of series connected circuit breakers in a<br />

combination that allows some breakers<br />

to have lower individual interrupting<br />

ratings than the available fault current.<br />

This is permitted as long as the series<br />

combination has been tested and certified<br />

by UL.<br />

The table below lists specific main<br />

and branch breaker series combinations<br />

that are marked on all P1 panels.<br />

All combinations shown have been tested<br />

for use in P1 panelboards and<br />

are UL listed. Other combinations are<br />

available. See Circuit Breaker Section,<br />

of this book.<br />

These series ratings must be specified on<br />

order at time of entry.<br />

a P1 400 amp main breaker panels have wire bending<br />

space available for 600 kcmil.<br />

b 400A main breaker is vertical mounted.<br />

For inches / millimeters conversion, see Application Data section.<br />

c Feed-thru lug wire bending space is 15.000" and neutral<br />

wire bending space is 15.880" on 400A panel.<br />

d P1 panel limited to (1) subfeed 250 amperes max.<br />

See Branch Breaker Side Gutter Chart for<br />

Revised P1 Backfed Options.<br />

11-18<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Panelboards<br />

Circuit Breaker / Lighting and Distribution<br />

Selection<br />

Shown with Standard Mains, Top Fed and Surface Trim<br />

Catalog number is for aluminum main bus. For optional copper<br />

main bus change “A” in position 11 to “C”.<br />

Panels are top feed, surface mounted. For bottom feed, change<br />

“T” in position 12 to “B”. For flush mounting, change “S” in<br />

position 13 to “F”.<br />

Table P1-16 – Main Lugs Only<br />

Main Lug Only<br />

Max Panel<br />

Amp<br />

Rating<br />

125<br />

250<br />

400<br />

Max<br />

1-Pole<br />

Circuits<br />

Box<br />

Height<br />

(in.)<br />

Original P1 –<br />

Subfeed Space<br />

208Y/120V 3-Phase<br />

4-Wire Catalog #<br />

Revised P1 –<br />

Subfeed Space Original P1 –<br />

Subfeed Space<br />

208Y/120V 3-Phase<br />

4-Wire Catalog #<br />

120/240V 1-Phase<br />

3-Wire Catalog #<br />

Revised P1 –<br />

Subfeed Space Original P1 –<br />

Subfeed Space<br />

120/240V 1-Phase<br />

3-Wire Catalog #<br />

480Y/277V 3-Phase<br />

4-Wire Catalog #<br />

Revised P1 –<br />

Subfeed Space <br />

480Y/277V 3-Phase<br />

4-Wire Catalog #<br />

18 32 P1C18ML125ATS P1C18ML125ATST P1A18ML125ATS P1A18ML125ATST P1E18ML125ATS P1E18ML125ATST <br />

30 38 P1C30ML125ATS P1C30ML125ATST P1A30ML125ATS P1A30ML125ATST P1E30ML125ATS P1E30ML125ATST<br />

42 44 P1C42ML125ATS P1C42ML125ATST P1A42ML125ATS P1A42ML125ATST P1E42ML125ATS P1E42ML125ATST<br />

54 50 N/A P1C54ML125ATST N/A P1A54ML125ATST N/A P1E54ML125ATST<br />

66 56 N/A P1C66ML125ATST N/A P1A66ML125ATST N/A P1E66ML125ATST<br />

18 32 P1C18ML250ATS P1C18ML250ATST P1A18ML250ATS P1A18ML250ATST P1E18ML250ATS P1E18ML250ATST <br />

30 38 P1C30ML250ATS P1C30ML250ATST P1A30ML250ATS P1A30ML250ATST P1E30ML250ATS P1E30ML250ATST<br />

42 44 P1C42ML250ATS P1C42ML250ATST P1A42ML250ATS P1A42ML250ATST P1E42ML250ATS P1E42ML250ATST<br />

54 50 N/A P1C54ML250ATST N/A P1A54ML250ATST N/A P1E54ML250ATST<br />

66 56 N/A P1C66ML250ATST N/A P1A66ML250ATST N/A P1E66ML250ATST<br />

18 56 P1C18ML400ATS – P1A18ML400ATS – P1E18ML400ATS –<br />

30 62 P1C30ML400ATS P1C30ML400ATST P1A30ML400ATS P1A30ML400ATST P1E30ML400ATS P1E30ML400ATST<br />

42 68 P1C42ML400ATS P1C42ML400ATST P1A42ML400ATS P1A42ML400ATST P1E42ML400ATS P1E42ML400ATST<br />

54 74 — P1C54ML400ATST — P1A54ML400ATST — P1E54ML400ATST<br />

66 74 — P1C66ML400ATSN — P1A66ML400ATSN — P1E66ML400ATSN <br />

Table P1-17 – Main Circuit Breaker<br />

100<br />

125<br />

225<br />

250<br />

400<br />

Replace fifth and sixth position in panelboard catalog number, with<br />

alternate main breaker code.<br />

Note: Original P1 was produced until 2015 and in January the revised P1<br />

was introduced. All interior numbers that end with “T” or “N” are the new<br />

Revised interiors. T” at end of catalog number indicates there is a Subfeed<br />

area available. “N” at end of catalog number indicates there is no Subfeed<br />

area available.<br />

18 32 P1C18BL100ATS P1C18BL100ATST P1A18BL100ATS P1A18BL100ATST P1E18BD100ATS P1E18BD100ATST <br />

30 38 P1C30BL100ATS P1C30BL100ATST P1A30BL100ATS P1A30BL100ATST P1E30BD100ATS P1E30BD100ATST<br />

42 44 P1C42BL100ATS P1C42BL100ATST P1A42BL100ATS P1A42BL100ATST P1E42BD100ATS P1E42BD100ATST<br />

54 50 — P1C54BL100ATST — P1A54BL100ATST — P1E54BD100ATST<br />

66 56 — P1C66BL100ATST — P1A66BL100ATST — P1E66BD100ATST<br />

18 32 P1C18NB125ATS P1C18NB125ATST — — P1E18NB125ATS P1E18NB125ATST <br />

30 38 P1C30NB125ATS P1C30NB125ATST — — P1E30NB125ATS P1E30NB125ATST<br />

42 44 P1C42NB125ATS P1C42NB125ATST — — P1E42NB125ATS P1E42NB125ATST<br />

54 50 — P1C54NB125ATST — — — P1E54NB125ATST<br />

66 56 — P1C66NB125ATST — — — P1E66NB125ATST<br />

18 32 P1C18QR225ATS P1C18QR225ATST P1A18QR225ATS P1A18QR225ATST P1E18FX250ATS P1E18FX225ATST <br />

30 38 P1C30QR225ATS P1C30QR225ATST P1A30QR225ATS P1A30QR225ATST P1E30FX250ATS P1E30FX225ATST<br />

42 44 P1C42QR225ATS P1C42QR225ATST P1A42QR225ATS P1A42QR225ATST P1E42FX250ATS P1E42FX225ATST<br />

54 50 — P1C54QR225ATST — P1A54QR225ATST — P1E54FX225ATST<br />

66 56 — P1C66QR225ATST — P1A66QR225ATST — P1E66FX225ATST<br />

18 32 P1C18FX250ATS P1C18FX250ATST P1A18FX250ATS P1A18FX250ATST P1E18FX250ATS P1E18FX250ATST <br />

30 38 P1C30FX250ATS P1C30FX250ATST P1A30FX250ATS P1A30FX250ATST P1E30FX250ATS P1E30FX250ATST<br />

42 44 P1C42FX250ATS P1C42FX250ATST P1A42FX250ATS P1A42FX250ATST P1E42FX250ATS P1E42FX250ATST<br />

54 50 — P1C54FX250ATST — P1A54FX250ATST — P1E54FX250ATST<br />

66 56 — P1C66FX250ATST — P1A66FX250ATST — P1E66FX250ATST<br />

18 56 P1C18JX400ATS — P1A18JX400ATS — P1E18JX400ATS —<br />

30 62 P1C30JX400ATS P1C30JX400ATST P1A30JX400ATS P1A30JX400ATST P1E30JX400ATS P1E30JX400ATST<br />

42 68 P1C42JX400ATS P1C42JX400ATST P1A42JX400ATS P1A42JX400ATST P1E42JX400ATS P1E42JX400ATST<br />

54 74 — P1C54JX400ATST — P1A54JX400ATST — P1E54JX400ATST<br />

66 2 74 2 — P1C66JX400ATSN — P1A66JX400ATSN — P1E66JX400ATSN <br />

Table P1-18 – Standard Enclosures<br />

Catalog Number<br />

Box<br />

Height Type 1 Standard Trim<br />

(in.) Box Surface Flush Type 3R Type 3R/12 <br />

26 B26 S26B F26B NR26 WP26<br />

32 B32 S32B F32B NR32 WP32<br />

38 B38 S38B F38B NR38 WP38<br />

44 B44 S44B F44B NR44 WP44<br />

50 B50 S50B F50B NR50 WP50<br />

56 B56 S56B F56B NR56 WP56<br />

62 B62 S62B F62B NR62 WP62<br />

68 B68 S68B F68B NR68 WP68<br />

74 B74 S74B F74B NR74 WP74<br />

For all products without subfeed space - change<br />

“T” at end to “N” and reduce box size by 6”.<br />

No sub-feed space only for 400A 66 circuit.<br />

BL/BQD/GB Type Mains are only available as Back-Fed. No kits are available for<br />

use in Main or Sub-feedspace. (GB Type includes NGB, HGB and LGB Breakers).<br />

These breakers take up branch circuit space.<br />

xGB interiors are not available as Non-Feed-Thru, without Subfeed Space.<br />

16 GA std., Optional 14 GA & 12 GA Enclosures only.<br />

14 Gauge Steel only.<br />

16 Gauge Can w/ 14 Gauge Front.<br />

The New Revised P1 (18 circuit 250A only) is limited to 100A per connection<br />

(200A per pair) when installing Branch Breakers across from one another. All<br />

other configurations allow 125A per connection max. (250A per pair max.)<br />

11 PANELBOARDS<br />

Product Category PBSB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-19


Panelboards<br />

Circuit Breaker / Lighting and Distribution<br />

Revised on 04/30/19<br />

Selection<br />

11<br />

PANELBOARDS<br />

Table P1-3 – Main Breaker Panel Size Selector – Revised P1<br />

Max<br />

Ampere<br />

rating<br />

100<br />

125<br />

225<br />

250<br />

400<br />

Main<br />

Breaker<br />

Types<br />

BL , BLH ,<br />

HBL , BQD <br />

NGB , HGB ,<br />

LGB <br />

ED4<br />

ED6, HED4<br />

QR2, QRH2,<br />

HQR2, HQR2H<br />

FXD6, FD6,<br />

HFD6, HFXD6<br />

JD6, JXD6,<br />

HJD6,<br />

HJXD6<br />

Connections suitable<br />

for Cu or Al<br />

#8-#6 AWG Cu or Al<br />

#8-6 AWG Cu or<br />

#8-4 AWG Al<br />

#8-#1 AWG Cu or<br />

#6-#1/0 AWG Al<br />

15-30 amp: #14-#6 Cu or<br />

#12-#6 Al<br />

35-125 amp: #6-1/0 Cu<br />

#4-2/0 Al<br />

#14-#10 AWG Cu or<br />

#12-10 AWG Al<br />

#3-3/0 Cu or #1-2/0 Al<br />

#3-3/0 Cu or #1-2/0 Al<br />

#6 AWG-300 Kcmil (Cu) or<br />

#4 AWG-300 Kcmil (Al)<br />

#6 AWG-350 Kcmil (Cu) or<br />

#4 AWG-350 Kcmil (Al)<br />

3/0-500 Kcmil (Cu) or<br />

4/0-500 Kcmil (Al)<br />

Max # Max #<br />

Poles<br />

FT 1 Poles<br />

NFT<br />

Dimensions in inches (mm)<br />

Unit Space<br />

Box Height<br />

FT NFT<br />

A A B<br />

Weight in<br />

Lbs. (kg)<br />

18 – 9 26 (661) 90 (41)<br />

18 30 9 15 32 (813) 105 (48)<br />

30 42 15 21 38 (965) 120 (55)<br />

42 54 21 27 44 (1118) 135 (61)<br />

54 66 27 33 50 (1270) 150 (67)<br />

66 – 33 – 56 (1423) 165 (73)<br />

18 – 9 26 (661) 95 (43)<br />

18 30 9 15 32 (813) 110 (50)<br />

30 42 15 21 38 (965) 125 (57)<br />

42 54 21 27 44 (1118) 140 (64)<br />

54 66 27 33 50 (1270) 155 (71)<br />

66 – 33 – 56 (1423) 170 (78)<br />

18 – 9 26 (661) 95 (43)<br />

18 30 9 15 32 (813) 110 (50)<br />

30 42 15 21 38 (965) 125 (57)<br />

42 54 21 27 44 (1118) 140 (64)<br />

54 66 27 33 50 (1270) 155 (71)<br />

66 – 33 – 56 (1423) 170 (78)<br />

– 30 – 15 56 (1423) 172 (78)<br />

30 42 15 21 62 (1575) 190 (86)<br />

42 54 21 27 68 (1728) 208 (95)<br />

54 66 27 33 74 (1880) 226 (104)<br />

Note: Main breakers use breaker connectors. For sizes, see breaker connector chart. 400A MLO Panels have wire bend space for<br />

600kcmil CU & AL wire when using standard lugs. With optional 750kcmil AL/CU connectors, wire bend space is available for up to<br />

750kcmil AL wire, but is still limited to 600kcmil CU wire.<br />

400A 66 circuit only available with non-feed thru versions.<br />

BL, BLH, HBL, BQD, and xGB mount in unit space and count in max. # of poles.<br />

Table P1-4 – Main Breaker Selection<br />

Ampere rating<br />

Breaker<br />

Types<br />

Max. Ir (kA) at<br />

240 AC 480/277V AC<br />

Main<br />

Breaker<br />

Code<br />

Additional Trip Values<br />

BL (STD) 10 BL 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100<br />

100<br />

BLH 22 BH 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100<br />

HBL 65 HB 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100<br />

BQD 65 14 BQ 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100<br />

NGB (STD) 100 25 NB 50, 60, 70, 80, 90, 100, 110, 125<br />

HGB 100 35 G2 50, 60, 70, 80, 90, 100, 110, 125<br />

125<br />

LGB 100 65 G3 50, 60, 70, 80, 90, 100, 110, 125<br />

ED4 (STD) 65 18 E4 50, 60, 70, 80, 90, 100, 110, 125<br />

ED6 (3-pole) d 65 25 E6 60, 70, 80, 90, 100, 110, 125<br />

HED4 42 42 H4 50, 60, 70, 80, 90, 100, 110, 125<br />

QR2 10 QR 100, 110, 125, 150, 175, 200, 225<br />

225<br />

QRH2 25 Q4 100, 110, 125, 150, 175, 200, 225<br />

HQR2 65 Q5 100, 110, 125, 150, 175, 200, 225<br />

HQR2H 100 Q6 100, 110, 125, 150, 175, 200, 225<br />

FXD6 (STD) 65 35 FX 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250<br />

250<br />

FD6 65 35 FD 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250<br />

HFD6 100 65 HF 70, 80, 90, 100, 150, 175, 200, 225, 250<br />

HFXD6 100 65 H2 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250<br />

JXD2 65 – JD 300, 400<br />

JXD6 (STD) 65 35 JX 200, 225, 250, 300, 350, 400<br />

400<br />

JD6 65 35 J6 200, 225, 250, 300, 350, 400<br />

HJD6 100 65 H6 200, 225, 250, 300, 350, 400<br />

HJXD6 100 65 H5 200, 225, 250, 300, 350, 400<br />

xGB interiors are not available as non-feed-thru without sub-feed space.<br />

d EDC/CED6 2-pole has limited amps available (20-50A).<br />

11-20<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category PBSB


Panelboards<br />

Revised on 04/30/19<br />

Circuit Breaker / Lighting and Distribution<br />

Selection<br />

Table P1-5 - Main Lug Panel Size Selector - Revised P1<br />

Maximum<br />

Ampere rating<br />

125<br />

(or)<br />

250<br />

400<br />

Max #<br />

Poles<br />

FT<br />

Max #<br />

Poles<br />

NFT<br />

Dimensions in inches (mm)<br />

Unit Space<br />

FT<br />

A<br />

NFT<br />

A<br />

Box Height<br />

B"<br />

Weight in<br />

Lbs. (kg)<br />

18 – 9 26 (661) 90 (41)<br />

18 30 9 15 32 (813) 105 (48)<br />

30 42 15 21 38 (965) 120 (55)<br />

42 54 21 27 44 (1118) 135 (61)<br />

54 66 27 33 50 (1270) 150 (67)<br />

66 – 33 – 56 (1423) 165 (73)<br />

– 30 – 15 56 (1423) 120 (55)<br />

30 42 15 21 62 (1575) 135 (61)<br />

42 54 21 27 68 (1728) 150 (68)<br />

54 66 27 33 74 (1880) 165 (75)<br />

MLO Connectors<br />

Suitable for<br />

(1) #6 AWG - 350 kcmil<br />

(CU or AL)<br />

AL (2) 1/0 - 250 kcmil or<br />

(1) #2 AWG - 600 kcmil<br />

CU (2) 1/0 - 4/0 or<br />

(1) #2 AWG - 600 kcmil<br />

11 PANELBOARDS<br />

Table P1-6 – Branch Circuit Breakers<br />

Circuit Breakers a Max IR (kA) at<br />

Max IR (kA) at<br />

Revised P1 Branch<br />

1-Pole 2-Pole and 3-Pole<br />

Amp<br />

Rating<br />

Trip<br />

Type<br />

100 Thermal<br />

Magnetic<br />

XX<br />

Special b<br />

Application<br />

Thermal<br />

Magnetic<br />

Electronic<br />

and misc.<br />

125 Thermal<br />

Magnetic<br />

Breaker<br />

Family<br />

Breaker<br />

Type 120V 277V 347V<br />

125V<br />

DC<br />

Amp<br />

Ratings<br />

Available<br />

120/<br />

240V<br />

240V<br />

480Y/<br />

277V<br />

480V<br />

600Y/<br />

347V<br />

600V<br />

125/<br />

250V<br />

DC<br />

250V<br />

DC<br />

Amp<br />

Ratings<br />

Available<br />

BL BL 10 — — — 15-70 10 10 — — — — — — 15-100 d<br />

BLH 22 — — — 15-70 22 22 — — — — — — 15-100 d<br />

HBL 65 — — — 15-50 65 65 — — — — — — 15-100<br />

BLG<br />

BL<br />

BQD<br />

BQD<br />

(CSA)<br />

BL<br />

BLG b 10 — — — 15-20 10 - — — — — — — 30<br />

BL(HID) b 10 — — — 15-30 10 - — — — — — — 15-30<br />

BQD e 65 14 — 14 15-100 — 65 14 — — — 14 — 15-100<br />

BQD6 f 65 — — 14 15-70 — 65 — 10 — 14 — 15-70<br />

AFCI/GFCI<br />

& Dual<br />

Function<br />

X — — — see special<br />

table page<br />

11-13<br />

x — — — — — — — see special<br />

table page<br />

11-13<br />

GB NGB 100 25 14 14 15-125 — 100 25 — 14 — 14 — 15-125<br />

HGB 100 35 14 14 15-125 — 100 35 — 14 — 14 — 15-125<br />

LGB 100 65 14 14 15-125 — 100 65 — 14 — 14 — 15-125<br />

3VA41 c<br />

info<br />

not yet<br />

available<br />

X X X X X X X — X — — X<br />

X X X X X X X — X — — X<br />

X X X X X X X — X — — X<br />

a Unit space is 1 inch per pole, except for Special Application with accessory included.<br />

- No branch kits available, unit space for all branch positions is twin mount.<br />

- Branch space is either for BL/BQD only (or) for xGB/3VA41 only. (after 3VA41 is made availabe).<br />

b BLG: Two-pole breaker is one phase and neutral. Three pole is two phases and neutral<br />

- See SpeedFax Page 7-31 for additional info. Some are Built to order. Allow 2-3 weeks delivery.<br />

c Availability and additional specs tbd, expected late 2019. (COMPAS may allow<br />

selection of alternate trip units)<br />

d 110A-125A BL/BLH (2-pole only) available as Main or<br />

Subfeed only in Revised P1 panels.<br />

e Approved for CSA and UL Listed.<br />

f Approved for CSA but not UL Listed.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-21


Panelboards<br />

Circuit Breaker / Lighting and Distribution<br />

Revised on 04/30/19<br />

Selection<br />

11<br />

PANELBOARDS<br />

Table P1-7 – Subfeed Breakers (Note: All BL/BQD/xGB Main Strap Kits can also be used for Subfeed.)<br />

Breaker<br />

Type<br />

Number<br />

of Poles<br />

Max. Interrupting Rating (kA)<br />

240V<br />

480Y/277V<br />

Available Trip Values<br />

QR2 2, 3 10 – 100, 110, 125, 150, 175, 200, 225<br />

QRH2 2, 3 25 – 100, 110, 125, 150, 175, 200, 225<br />

HQR2 2, 3 65 – 100, 110, 125, 150, 175, 200, 225<br />

HQR2H 2, 3 100 – 100, 110, 125, 150, 175, 200, 225<br />

ED4 2, 3 65 18 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 70, 80, 90, 100, 110, 125<br />

ED6 (3-pole) d 2, 3 65 25 20, 25, 30, 35, 40, 45, 50, 55, 60, 70, 80, 90, 100, 110, 125<br />

HED4 2, 3 100 42 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 70, 80, 90, 100, 110, 125<br />

HHED6 2, 3 100 65 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 70, 80, 90, 100, 110, 125<br />

FXD6 2, 3 65 35 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250<br />

FD6 2, 3 65 35 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250<br />

HFD6 2, 3 100 65 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250<br />

HFXD6 2, 3 100 65 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250<br />

Table P1-8 – Breaker Mounting Kit<br />

Main or Subfeed Strap Kit w/o Breaker<br />

Ampere<br />

Rating Breaker Types Service<br />

Table P1-9 – Lug Kits (Main or Feed-Thru)<br />

Amp<br />

Rating<br />

250<br />

400<br />

Matl.<br />

AL<br />

CU<br />

AL<br />

CU<br />

400 AL<br />

Wire Range<br />

(includes Neutral)<br />

(1) #6 AWG-<br />

350 kcmil (CU or AL)<br />

(1) #6 AWG-<br />

350 kcmil (CU)<br />

(2) 1/0 - 250 kcmil<br />

or (1) #2 AWG-600 kcmil<br />

(2) 1/0 - 4/0<br />

or (1) 1/0 - 600 kcmil<br />

(1) AL 1/0-750 kcmil<br />

(2) AL/CU 250kcmil<br />

max.<br />

[max.(1) 600 kcmil CU<br />

wire]<br />

Original P1<br />

Catalog<br />

Number<br />

Revised P1<br />

Catalog<br />

Number b<br />

100A BL, BLH, HBL 1-Phase MBKBL1 MBKBL1A<br />

3-Phase MBKBL3 MBKBL3A<br />

100A BQD<br />

—<br />

1-Phase<br />

125A NGB, HGB, LGB MBKNB1<br />

MBKBC1NBA<br />

100A BQD<br />

MBKBC3<br />

3-Phase<br />

125A NGB, HGB, LGB MBKNB3<br />

MBKBC3NBA<br />

125A ED4, ED6, HED4, 1-Phase MBKED1 MBKED1A<br />

HHED6<br />

3-Phase MBKED3 MBKED3A<br />

225A QJ2, QJH2, QJ2H 1-Phase MBKQJ1 MBKQJ1A<br />

3-Phase MBKQJ3 MBKQJ3A<br />

225A QR2, QRH2, HQR2, 1-Phase MBKQR1 MBKQR1A<br />

HQR2H<br />

3-Phase MBKQR3 MBKQR3A<br />

250A FXD6, FD6, HFD6, 1-Phase MBKFD1 MBKFD1A<br />

HFXD6<br />

3-Phase MBKFD3 MBKFD3A<br />

400A a JXD2, JD6, JXD6, 1-Phase MBKJD1 MBKJD1A<br />

HJD6, HJXD6<br />

3-Phase MBKJD3 MBKJD3A<br />

a400 amp kit is for main only — not allowed for subfeed breaker.<br />

MBKBFA kit is available to mount BL/BQD/xGB 2-pole or 3-pole in unit space as a<br />

"Back-Fed Main". This occupies branch space and reduces circuit count by 2 or 3 positions.<br />

(includes Neutral Lug, "MAIN" label and instructions).<br />

Although QR is rated 250A, it is limited to 225A in panelboard.<br />

Revised<br />

P1<br />

Catalog<br />

Number<br />

Original<br />

Catalog<br />

Service Number<br />

1 Phase MLKA1 MLKA1A<br />

3 Phase MLKA3 MLKA3A<br />

1 Phase MLKC1 MLKC1A<br />

3 Phase MLKC3 MLKC3A<br />

1 Phase 4MLKA1 4MLKA1A<br />

3 Phase 4MLKA3 4MLKA3A<br />

1 Phase 4MLKC1 4MLKC1A<br />

3 Phase 4MLKC3 4MLKC3A<br />

1 Phase — 4MLKA1B<br />

3 Phase — 4MLKA3B<br />

Table P1-10 – Copper Neutral Lug Kits – 250A<br />

No. of<br />

Circuits<br />

18<br />

Description<br />

Original P1<br />

Catalog<br />

Number<br />

CNLK18<br />

Revised P1<br />

Catalog<br />

Number<br />

Use 30 ckt kit<br />

30 2 or 4 Branch Neutral Strips, CNLK30 CNLK30A<br />

42 1 Main Neutral Lug, Hardware CNLK42 CNLK42A<br />

54, 66 — CNLK54A<br />

Table P1-10A – 2/0 Neutral Lug Kits – 250A and 400A<br />

No. of<br />

Circuits<br />

18<br />

Original P1<br />

Catalog<br />

Number<br />

Revised P1<br />

Catalog<br />

Number<br />

Description<br />

— Use 30 ckt kit<br />

30 2 or 4 Branch Neutral Strips, — LNLK30A<br />

42 Hardware<br />

— LNLK42A<br />

54, 66 — LNLK54A<br />

Table P1-11 – 200% Neutral Lug Kits – 250A<br />

No. of<br />

Circuits<br />

18<br />

Original P1<br />

Catalog<br />

Number<br />

2NLK18<br />

Revised P1<br />

Catalog<br />

Number<br />

Description<br />

Use 30 ckt kit<br />

30 2 or 4 Branch Neutral Strips, 2NLK30 2NLK30A<br />

42 2 Main Neutral Lugs, Hardware 2NLK42 2NLK42A<br />

54, 66 — 2NLK54A<br />

Table P1-12 – 200% Neutral Lug Kits – 400A<br />

No. of<br />

Circuits<br />

18<br />

Description<br />

Original P1<br />

Catalog<br />

Number<br />

42NLK18<br />

Revised P1<br />

Catalog<br />

Number<br />

N/A<br />

30<br />

42<br />

2 or 4 Branch Neutral Strips,<br />

1 Main 600 kcmil Neutral Lug,<br />

Hardware<br />

42NLK30<br />

42NLK42<br />

42NLK30A<br />

42NLK42A<br />

54, 66 — 42NLK54A<br />

NOTES:<br />

a Original P1 kits will not work with Revised P1 interiors if the chart shows different part numbers for each.<br />

Revised P1 kits will not work with Original P1 interiors if the chart shows different part numbers for each.<br />

c Field installable Service Entrance Barrier kits are now available as required by UL67 (In COMPAS, you must<br />

select Service Entrance Required).<br />

c ED6/CED6 2-pole has limited amps available (20-50A)<br />

11-22<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Panelboards<br />

Circuit Breaker / Lighting and Distribution<br />

Revised on 04/30/19<br />

Selection<br />

Table P1-13 – Main Breaker Gutter Dimensions Inches (mm)<br />

Main<br />

Gutter Space<br />

Neutral Location<br />

to Endwall<br />

Breaker<br />

20” wide box 24” wide box 20” wide box<br />

BL, BLH, HBL 8.680 (220) 10.690 (272) 10.500 (267)<br />

BQD 7.880 (200) 9.880 (251) 10.500 (267)<br />

NGB, HGB, LGB 7.770 (197) 9.770 (248) 10.500 (267)<br />

ED4, ED6, HED4 6.125 (156) 8.125 (206) 10.500 (267)<br />

QR2, QRH2, HQR2, HQR2H 6.500 (165) 8.500 (216) 10.500 (267)<br />

FD6, FXD6, HFD6, HFXD6 5.250 (133) 7.250 (184) 10.500 (267)<br />

JD6, JXD6 15.000 (381) 15.000 (381) 26.500 (674)<br />

<br />

JD frame mounted vertically.<br />

For Revised P1 with Back-fed Main option, use Side Gutter<br />

Wiring Spec Table P1-15.<br />

<br />

These dimensions are for Revised P1 only. See Original P1 cut sheets for valid<br />

dimensions if needed (P1 production prior to January 2015).<br />

Table P1-14 – Main Lug End Gutter Dimensions Inches (mm)<br />

Amp End Gutter<br />

Neutral Location - to Endwall<br />

Rating 20” wide box 24” wide box 20” wide box 24” wide box<br />

125 9.500 (242) 9.500 (242) 10.500 (267) 10.500 (267)<br />

250 9.500 (242) 9.500 (242) 10.500 (267) 10.500 (267)<br />

400 25.500 (648) 25.500 (648) 26.750 (680) 26.750 (680)<br />

NOTE: Feed-thru lug and neutral wire bending space is 15.000” and 16.250” respectively<br />

on 400A panel.<br />

Table P1-15 – Side Gutter Wiring<br />

Space Inches (mm) (Fig P1-1) Fig P1-1<br />

Reference<br />

Letter<br />

Panel<br />

Width 20”<br />

Panel<br />

Width 24”<br />

Optional<br />

A 6.375 (167) 8.375 (213)<br />

B 5.500 (140) 7.500 (191)<br />

C 5.000 (127) 7.000 (178)<br />

D 6.125 (156) 8.125 (206)<br />

E 6.500 (165) 8.500 (216)<br />

F 5.250 (133) 7.250 (184)<br />

<br />

Subfeed mounting limit 1 per panel.<br />

Panel Width<br />

20 in. (508 mm)<br />

For all Revised P1 panels using BL/BQD or xGB breakers as<br />

mains in back-fed position, use this chart for wiring space.<br />

Miscellaneous Parts and Accessories<br />

Catalog # Description<br />

BK1<br />

Bonding Kit for 400A max. Original P1 Panels<br />

BK1A<br />

Bonding Kit for 400A max. Revised P1 Panels<br />

BK2 Bonding kit for S1/S2 400 & 600<br />

BK3<br />

Bonding kit<br />

IMK1<br />

Interior Adjusting Kit<br />

LPDC01 Directory Card (Pack of 10; ref. 12-1110-01)<br />

LPDC02 Directory Card Holder (Pack of 10; ref. 11-1824-01)<br />

MCHK<br />

Metal Card Holder Kit<br />

NBK03<br />

Number Strips 1–42. Stick-on type (P1 Panel only)<br />

NBK04<br />

Number Strips 43–84. Stick-on type;<br />

Use w/ P1 series Panels<br />

NBK05<br />

Number Strips 85–126. Stick-on type;<br />

Use w/ P1 series Panels<br />

NBK06<br />

Number Strips 127–168. Stick-on type;<br />

Use w/ P1 series Panels<br />

EGK<br />

AL Ground Bus 44 Connections<br />

ECGK<br />

CU Ground Bus 44 Connections<br />

IGK<br />

Insulated AL Ground Bus<br />

ICGK<br />

Insulated CU Ground Bus<br />

SEBKRP1V1 c FD, QJ, QR Service Entrance Barrier Kit<br />

(Revised P1)<br />

SEBKRP1V2 c ED Service Entrance Barrier Kit (Revised P1)<br />

SEBKRP1V3 c BL/BQD Service Entrance Barrier Kit<br />

(Revised P1) back-fed<br />

SEBKRP1V4 c xGB Service Entrance Barrier Kit<br />

(Revised P1) back-fed<br />

SEBKRP1V5 c BL/BQD/xGB Service Entrance Barrier Kit<br />

(RP1 in main space)<br />

SEBKP1P2P3V1 c JD, LD Service Entrance Barrier Kit<br />

(RP1, P1, P2, P3)<br />

EWK1<br />

End Wall Kit with Knockouts (20" W x 5.75" DP)<br />

EWK2<br />

End Wall Kit with Knockouts (24" W x 7.75" DP)<br />

EBF1<br />

NEB/HEB Filler Plate<br />

P1SCRWS Package of 42 breaker mounting screws for P1<br />

DFFP1<br />

1" Branch circuit filler plate (used for BL/BQD/<br />

xGB/xGB2/ED blank positions) (suitable for<br />

replacing QF3 in P1 thru P5 Panelboards and<br />

Switchboards)<br />

P1CONBPHCU Connector kit – 6 pcs. B-phase Copper<br />

P1CONBPHAL Connector kit – 6 pcs. B-phase Aluminum<br />

P1CONACPHCU d Connector kit – 6 pcs. A or C-phase Copper<br />

MBKQRFK<br />

P1/Revised P1 Filler for 1PH/3PH QR.<br />

Horizontal mount only.<br />

ANSI/NEMA<br />

PB 1.1-2013<br />

General Instructions for Proper Installation,<br />

Operation, and Maintenance of Panelboards<br />

Rated 600 Volts or Less (O&M Manual) <br />

Replacement parts only.<br />

b PDF can be downloaded (at no cost) and printed at:<br />

www.nema.org/standards/pages/Panelboards.aspx<br />

c Factory installed and Field installable Service Entrance<br />

Barrier kits are now available as required by UL67. (In<br />

COMPAS, you must select Service Entrance Required.)<br />

d Use for both CU + AL bus interiors.<br />

11 PANELBOARDS<br />

Feed-Thru (FT) Non-Feed-Thru (NFT) Example of Back-fed xGB Main breaker installed<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-23


Panelboards<br />

Type P1 Panelboard Modifications and Additions<br />

Revised on 04/30/19<br />

Selection<br />

11<br />

PANELBOARDS<br />

Panel Options<br />

Enclosures<br />

• Extra gutter to sides or ends of the can<br />

• 24” wide boxes<br />

• Hinged to box trim<br />

• Door-in-door trims<br />

• Screw to box trims<br />

• Piano hinge trims<br />

• Painted boxes (ANSI 61 Light Gray is standard color)<br />

• Custom colors<br />

• Increase gauge trims and boxes (See pages 12-13)<br />

• Stainless steel trims (304 SS only) for Type 1 enclosures<br />

• Type 1 enclosures (Std 16 Gage / Optional 14 or 12 Gage)<br />

• Type 1 Standard are A60 Galvanealed non painted (Painted Type 1<br />

use HRPO material)<br />

• NEMA 3R/12 enclosures 16 Gauge Can w/ 14 Gauge front)<br />

• NEMA 4 enclosures (14 Gauge only)<br />

• NEMA 4X enclosures (14 Gauge only - 304SS Std, 316SS<br />

Optional)<br />

• Special Keyed Locks (Keys are not supplied)<br />

• Panel skirts<br />

• Gaskets between trim and box<br />

TEY<br />

TEU1<br />

Cat 60<br />

LL803<br />

LL806<br />

Yale 47 (NYC)<br />

National C413A<br />

Beck Lock 7-pin tumbler<br />

Southco 1 4 Fastener<br />

Corbin 1001 FAB7<br />

*See page 11-7 for more information.<br />

All fit FAS-Latch Front*<br />

Special non-FAS-Latch*<br />

Panel Modifications<br />

• Main Bus<br />

Standard main bus is tin-plated aluminum. For copper main<br />

bus, add from the table for each panel. Includes copper<br />

neutral cross bar. For copper neutral branch lugs, see<br />

miscellaneous.<br />

• Compression lug for MLO a<br />

• Contactor mains - Mount in 23” enclosure ahead of panel.<br />

– Asco 920 through 225 amps <br />

– Asco 911 through 150 amps <br />

– Siemens LEN through 30 amps <br />

• Branch and main breaker accessories<br />

– Handle blocks<br />

– Handle locks<br />

• Feed-thru lugs <br />

Cannot be used in conjunction with SPD/TVSS or subfeed<br />

breakers. Do not add height to the panel.<br />

Feed-thru Lugs<br />

Amp Rating<br />

250<br />

400<br />

• 200% neutral <br />

Type<br />

AL/CU<br />

Mechanical<br />

CU<br />

Mechanical<br />

AL/CU<br />

Compression<br />

AL/CU<br />

AWG Mechanical<br />

CU<br />

AL/CU<br />

Compression<br />

Note: Specify copper or aluminum cable.<br />

Connector<br />

CU/AL Range<br />

(1)–#6 AWG-<br />

350 kcmil<br />

(1)–#6 AWG-<br />

350 kcmil<br />

(1)–#6 AWG-<br />

350 kcmil<br />

(2)–#1/0 -<br />

250 kcmil or<br />

(1)–#2 AWG-<br />

600 kcmil<br />

(1)–1/0-600 kcmil<br />

(2)-1/0-4/0<br />

(1) 400-600 kcmil AL<br />

(1) 400-500 kcmil CU<br />

Do not increase panel or enclosure size.<br />

Accessories on 1” pole breakers (BL, BQD, xGB, ED) will take 1” unit space.<br />

External to the panel, supplied in a separate enclosure.<br />

• Copper lugs, mechanical line and branch neutral <br />

• Bus mounted SPD/TVSS <br />

• Service entrance labeling<br />

• Factory installed and Field installable Service Entrance Barrier<br />

kits are now available as required by UL67<br />

• Grounding of Panelboards<br />

Ground Bars except for brazed to box are shipped with<br />

the panel interior.<br />

– Non-Insulated Equipment Ground Bar – standard<br />

– Copper Non-Insulated Ground Bar – optional<br />

– AL Insulated Equipment Ground Bar – optional<br />

– CU Insulated Equipment Ground Bar – optional<br />

– Ground Bar Brazed to Box (recommended for painted boxes)<br />

• Shunt Trip on Main or Branch b<br />

BL, BLH, HBL, BQD, xGB as branch use<br />

1” unit space for shunt trip.<br />

QR2, QRH2, HQR2, HQR2H, ED2, ED4, ED6,<br />

HED4, HED6, HHED6, FD6, FXD6, HFD6<br />

HFXD6, JXD6, JD6, HJD6, HJXD6<br />

• Remote control switches – 480V AC max. mounted in<br />

a 23” enclosure to be cable connected to the panel.<br />

• Time Clocks – mounted in a 23” enclosure to be cable<br />

connected to the panel. Tork time clock can be supplied and<br />

mounted in panelboard cabinet.<br />

Time Clock Information and Options<br />

Time Clock (1- or 2-Pole, Single or Double Throw Contacts,<br />

3-Pole Single Throw) 277V Maximum with Plain Dial<br />

Options:<br />

Astronomical Dial<br />

An Omitting Device<br />

Reserve Power or Carryover<br />

Space and Mounting Provisions Only<br />

11-24<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category PBSB


Panelboards<br />

Type P1 Panelboard Modifications and Additions<br />

Revised on 04/30/19<br />

Selection<br />

Compression Lugs<br />

Table P1-19 – Lugs<br />

Style<br />

MLO<br />

Main<br />

Breaker<br />

Amp<br />

Rating<br />

125<br />

250<br />

Breaker<br />

Type<br />

Compression<br />

Connectors<br />

N/A (1) #6 AWG - 350 kcmil None<br />

Box Height<br />

Addition<br />

400 N/A<br />

(1) 400 - 600 kcmil AL<br />

(1) 400 - 500 kcmil CU<br />

None<br />

125 ED4, ED6, HED4 (1) #14 AWG - 2/0 Box must go to 24” wide<br />

225<br />

QR2, QRH2,<br />

HQR2, HQR2H<br />

250 FXD6, HFD6<br />

(1) #6 AWG - 350 kcmil<br />

CU or AL<br />

(1) #6 AWG - 350 kcmil<br />

CU or AL<br />

Box must go to 24” wide<br />

Box must go to 24” wide<br />

Note: Standard compression lugs used for P1 panels are range taking lugs and require a<br />

particular crimping tool (tool is Hubbell/Anderson Versa Crimp VC6 -for 250A) to accommodate<br />

the range. Consult factory for information. 200% neutral not available with compression lugs.<br />

xGB breakers cannot accommodate compression lugs. (For 400A tool use Hubbell/Anderson<br />

Versa Crimp VC6FT/VC7FT - see instruction sheet for details.)<br />

Enclosure Modifications<br />

NEMA-4–Water Tight, Dust Tight,<br />

Steel Enclosure<br />

(Actual NEMA-4 enclosure is larger than<br />

standard Type 1 enclosure. See chart<br />

below for reference to approximate<br />

actual size.)<br />

Table P1-20<br />

Standard<br />

Box Height<br />

(in inches)<br />

Actual NEMA 4<br />

Enclosure Size<br />

H W D<br />

32 32 20 8<br />

38 42 30 8<br />

44 48 36 8<br />

56 60 36 10<br />

Note: Larger NEMA 4 enclosures are not<br />

available.<br />

11 PANELBOARDS<br />

Table P1-21 – NEMA Type 4X (Water Tight, Dust Tight and Corrosion Resistant)<br />

Enclosure – Stainless Steel (304SS is standard)<br />

Note: 316SS is optional - must be specified<br />

Catalog<br />

Number<br />

Enclosure – Non-metalic / Fiberglass<br />

Size (inches)<br />

Size (inches)<br />

Ref. Size (inches)<br />

Catalog<br />

Catalog<br />

Interior<br />

H W D Number H W D Number Height H W D<br />

Custom order<br />

in COMPAS<br />

Reference Number<br />

B4X26 26 20 5.75 24B4X26 26 24 5.75 tbd 26 30 24 8 A30H2408GQRLP<br />

B4X32 32 20 5.75 24B4X32 32 24 5.75 tbd 32 36 30 8 A36H3008GQRLP<br />

B4X38 38 20 5.75 24B4X38 38 24 5.75 tbd 38<br />

B4X44 44 20 5.75 24B4X44 44 24 5.75 tbd 44<br />

48 36 12 A48H3612GQRLP<br />

B4X50 50 20 5.75 24B4X50 50 24 5.75 tbd 50<br />

B4X56 56 20 5.75 24B4X56 56 24 5.75 tbd 56<br />

60 36 12 A60H3612GQRLP<br />

B4X62 62 20 5.75 24B4X62 62 24 5.75 tbd 62 na na na na<br />

B4X68 68 20 5.75 24B4X68 68 24 5.75 tbd 68 na na na na<br />

B4X74 74 20 5.75 24B4X74 74 24 5.75 tbd 74 na na na na<br />

Remote Switch Modifications<br />

Table P1-22 – Control Power<br />

Transformer<br />

Size<br />

VA Relay<br />

0, 1 50<br />

2 75<br />

3 150<br />

4 250<br />

Table P1-24 – Remote Control<br />

Switch Modification<br />

Description<br />

Auxiliary Contacts (mounted, not wired)<br />

2-Wire Control<br />

Table P1-23 – Applications for a Remote Switch<br />

Switch Type<br />

Modification<br />

920 Mounts in 23” relay cabinet as a main only<br />

LEN<br />

30A mounts in 23” relay cabinet as a main only<br />

Gauge Steel of Boxes/Fronts, Surface and Flush (see pgs. 11-6 & 11-7)<br />

Dimensions in Inches (mm)<br />

Gauge Steel<br />

H W Box Front/Door Type<br />

26-74 (660-1880) 20 (508) 16 14 Type 1<br />

26-74 (660-1880) 20 (508) 16 16/14 Type 3R/12<br />

32-60 (813-1524) 20-36 (508-914) 14 14 Type 4<br />

26-74 (660-1879) 20 (508) 14 14 Type 4X<br />

36-60 (914-1524) 30-36 (762-914) N/A N/A Type 4X Non-Metallic<br />

16 Gauge is Standard (14 Gauge & 12 Gauge are optional)<br />

15 Gauge Steel Can with 14 Gauge Door or Similar Approved Construction<br />

No Optional Gauge available<br />

304SS 14 Gauge Std., 316SS 14 Gauge optional<br />

Sizes do not match Standard Enclosure Sizes - See Table P1-21 - material is non-metallic - No Gauge Specified.<br />

f FAS-Latch is 14 GA only. Screw-to-Box, Hinge-to-Box, Door-in-Door (14 GA Std./12 GA Std. or 10 GA Optional)<br />

STB/HTB/DND with Piano Hinge (14 GA Std./12 GA Optional) (14 GA Stainless 304 Optional)<br />

Product Category PBSB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-25


Panelboards<br />

Type P1 Enclosure Details<br />

Revised on 04/30/19<br />

Dimensions<br />

11<br />

PANELBOARDS<br />

Type 1 Box<br />

Box is symmetrical<br />

0.313 in. Dia.<br />

0.313 in. Dia.<br />

³⁄₄ in.<br />

[19 ]<br />

20 in.<br />

[ 508 ]<br />

³⁄₄ in.<br />

[19 ]<br />

ounting Holes<br />

437 in. Square)<br />

(UL approved construction. 16 Gage Steel or equivalent alternate Construction.<br />

14 or 12 Gage is available as an optional special order.)<br />

G60 Galvanized is standard without paint.<br />

Type 3R and 3R/12 Box<br />

(Mounting Holes<br />

0.437 in. Square)<br />

8.0 in.<br />

[ 204 ]<br />

Flush Mounting<br />

8.0 in.<br />

[ 204 ]<br />

5.75 in.<br />

[ 146 ]<br />

(Mounting Holes<br />

0.437 in. Square)<br />

(Mounting Holes<br />

0.437 in. Square)<br />

Mounting Holes<br />

.437 in. Square)<br />

(Mounting Holes<br />

0.437 in. Square)<br />

(Mounting Holes<br />

0.437 in. Square)<br />

(Mounting Holes<br />

0.437 in. Square)<br />

23.0 in.<br />

[ 584 ]<br />

23.0 in.<br />

[ 584 ]<br />

(UL approved construction. 16 Gage Steel Can with<br />

14 Gage front or similar approved construction.)<br />

A60 Galvannealed with ANSI 61 light gray paint is standard.<br />

Dimensions are interior of the box. Add 5/8” to width for absolute<br />

dimension. Add 1/8” to height for absolute dimension.<br />

Dimensions shown in inches and millimeters [ ].<br />

11-26<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Panelboards<br />

Revised on 04/30/19<br />

Type P2 Panelboards<br />

General<br />

Features<br />

Flexibility is the hallmark of the P2 panel.<br />

This panel offers a wide array of factoryassembled<br />

options to meet almost all<br />

lighting panel applications. With this<br />

design, the ability to mix breaker frames<br />

in unit space up to 250 amps will also<br />

meet many distribution panel requirements<br />

in a much smaller package. Bussing<br />

options for the P2 vary from the typical<br />

temperature rated to 750 A/Si aluminum<br />

to 1000A/Si copper. Standard bussing in<br />

the P2 panel is tin-plated. Silver-plated<br />

copper is also offered as an option.<br />

Integrated time clocks, bus mounted<br />

contactors, as mains or sub mains, split<br />

bus, and subfeed lugs (up to 400 amp)<br />

are just a few of the options of this<br />

unique panel.<br />

Like a lighting panel, P2 is set up around<br />

18, 30, 42, 54, 66, 78, and 90 circuit<br />

configurations. It will also allow the user<br />

to configure the panel to the smallest<br />

possible size. The P2 panel starts with<br />

9" of unit space (18 circuits of 1" pole<br />

breakers). Breakers mounted in unit<br />

space can be mixed and matched to<br />

meet customer requirements. All 1" pole<br />

breakers (BL, BQD, xGB, xGB2, ED<br />

frames) are mounted in 3" or 6" pole<br />

increments. Breaker frames, above 125<br />

amps, are mounted in 6" single breaker<br />

mountings.<br />

As an example of a minimum panel, (6)<br />

20 amp 1-pole BL breakers (3" of unit<br />

space) and a 3-pole 225 amp QJ breaker<br />

(6" of unit space) equaling 9" of unit<br />

space can be configured in a P2 panel<br />

without any extra provisions or space<br />

required. FD 250 amp and JD 400 amp<br />

breakers are mounted as subfeed<br />

breakers outside of unit space.<br />

Another unique feature of the P2<br />

panel is that blank unit space can be<br />

added to allow for future expansions<br />

or modifications. Any expansions or<br />

modifications must be in 3" increments.<br />

BL, BQD, xGB, xGB2, and ED frame<br />

breakers have 3" or 6" pole kits, and<br />

can be mixed in unit space by these<br />

increments. Breakers of the same<br />

frame can cross from one mounting<br />

to another if contiguous. QR frame<br />

breakers are mounted in 6" increments<br />

for two- and three pole, single mounted<br />

units. Changes in the unit space length<br />

for BL, BQD, xGB, xGB2, or ED frame<br />

breakers require an addition deadfront,<br />

center strip kit. Check with sales or the<br />

factory for additional unit space kits.<br />

Main Lug / Main Breaker<br />

Enclosure – Standard Type 1 enclosure<br />

is 20" wide x 5.75" deep X. Box Height is<br />

determined by main device and unit<br />

space. See charts for box height.<br />

Voltage – 600V AC max.<br />

250V DC max.<br />

Amperage – 600 amp max.<br />

Short circuit rating – 200 KAIC max.<br />

symmetrical or equal to the lowest rated<br />

device installed unless a series rating<br />

is indicated. Panels with subfeed or<br />

feed-thru lugs without a main device,<br />

circuit breaker or fusible unit, are limited<br />

to a three-cycle rating. The three-cycle<br />

rating for the P2 panel is limited to 22<br />

KAIC. Note that the main device may<br />

be mounted remote from the panel.<br />

Bussing – The P2 panel has more<br />

options to meet market requirements.<br />

The standard bussing is temperature<br />

rated aluminum. The rating is per the<br />

requirements of UL 67 – the standard for<br />

panelboards. All aluminum bussing is<br />

tin-plated. Optional bussing for the P2<br />

panel is: 750 A/Si aluminum, temperature<br />

rated copper, and 1000 A/Si copper.<br />

The copper bus option for this panel is<br />

tin-plated.<br />

Weight – Approximate<br />

Total panelboard weight when filled<br />

with a normal quantity of breakers and<br />

accessories is about 3 lbs. (1 kg) per<br />

inch (54g per mm) of box height.<br />

11 PANELBOARDS<br />

Gauge Steel of Boxes/Fronts, Surface and Flush (see pgs. 11-6 & 11-7)<br />

Dimensions in Inches (mm)<br />

Gauge Steel<br />

H W Box Front/Door Type<br />

26-74 (660-1880) 20 (508) 16 14 Type 1<br />

26-74 (660-1880) 20 (508) 16 16/14 Type 3R/12<br />

32-60 (813-1524) 20-36 (508-914) 14 14 Type 4<br />

26-74 (660-1879) 20 (508) 14 14 Type 4X<br />

36-60 (914-1524) 30-36 (762-914) N/A N/A Type 4X Non-Metallic<br />

16 Gauge is Standard (14 Gauge & 12 Gauge are optional)<br />

15 Gauge Steel Can with 14 Gauge Door or Similar Approved Construction<br />

No Optional Gauge available<br />

304SS 14 Gauge Std., 316SS 14 Gauge optional<br />

Sizes do not match Standard Enclosure Sizes - See Table P1-21 - material is non-metallic - No Gauge Specified.<br />

f FAS-Latch is 14 GA only.<br />

Screw-to-Box, Hinge-to-Box, Door-in-Door (14 GA Std./12 GA Std. or 10 GA Optional)<br />

STB/HTB/DND with Piano Hinge (14 GA Std./12 GA Optional)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-27


Panelboards<br />

Type P2 Panelboards<br />

Revised on 04/30/19<br />

Selection/Dimensions<br />

11<br />

PANELBOARDS<br />

Standard Circuit P2 Panels (Neutral Configurations for up to 54 circuits max.)<br />

Table below shows minimum Box Size<br />

required for the Unit Space indicated<br />

with the Main Option at the top of each<br />

Column.<br />

n Adding other options generally will<br />

add to the box Height when configured<br />

in COMPAS. Also, there may be<br />

cost adders with each option.<br />

n The maximum number of 1" circuits<br />

supported is show at the bottom of<br />

each column in brackets. [54p] = max<br />

54 poles of 1" circuits supported (BL,<br />

BQD, ED, xGB, xGB2).<br />

n Unit space is available in 9", 15", 21",<br />

27", 33", 39", and 45" sizes.<br />

n Within unit space listed, the neutral<br />

will support up to 54 circuits.<br />

n When more then 54 circuits are<br />

required, COMPAS will configure with<br />

larger Extended Circuit Neutral - see<br />

Extended Circuit chart below for minimum<br />

box sizes.<br />

n Box sizes available: 26", 32", 38", 44",<br />

50", 62", 68", 74"<br />

“B”<br />

Dimension<br />

Box<br />

Height<br />

P2 Panels with Standard Line Lugs. Unit Space (starting with 9" and adding 6" increments) “A” Dimension<br />

Main Lugs<br />

Main Breakers<br />

125A<br />

250A<br />

400A<br />

600A<br />

125A Horiz.<br />

BL, BQD,<br />

xGB, ED<br />

125A<br />

Vert.<br />

ED <br />

125A<br />

Horiz.<br />

CED<br />

225A<br />

Horiz.<br />

QR<br />

26 9 — — 9 — — — — — — — — — — —<br />

32 15 9 — 15 9 9 9 — — — — — — — —<br />

38 21 15 9 21 15 15 15 9 9 — — — — — —<br />

44 27 21 15 27 21 21 21 15 15 9 — — — — —<br />

50 33 27 21 33 27 27 27 21 21 15 9 9 — — —<br />

56 39 33 27 39 33 33 33 27 27 21 15 15 — 9 —<br />

62 45 39 33 45 39 39 39 33 33 27 21 21 9 15 9<br />

68 45 45 39 45 45 45 45 39 39 33 27 27 15 21 15<br />

74 45 45 45 45 45 45 45 45 45 39 33 33 21 27 21<br />

[54p] [54p] [54p] [54p] [54p] [54p] [54p] [54p] [54p] [54p] [54p] [54p] [42p] [54p] [42p]<br />

225A<br />

Vert.<br />

QR <br />

250A<br />

Horiz.<br />

FD<br />

Extended Circuit P2 Panels (Neutral Configurations for more than 54 circuits)<br />

When COMPAS configuration has<br />

more than 54 circuits, the large neutral<br />

configuration is needed. Box size shown<br />

is the minimum available without any<br />

options.<br />

“B”<br />

Dimension<br />

Box<br />

Height<br />

250A<br />

Vert.<br />

FD <br />

250A<br />

Vert.<br />

CFD<br />

P2 Panels with Standard Line Lugs. Unit Space (starting with 9" and adding 6" increments) “A” Dimension<br />

Main Lugs<br />

Main Breakers<br />

125A<br />

250A<br />

400A<br />

600A<br />

125A Horiz.<br />

BL, BQD,<br />

xGB, ED<br />

n Unit space of 33", 39", and 45" are<br />

available.<br />

n Unit space will be reduced by<br />

selecting some options such as Feedthru<br />

lugs, Surge Protection Devices,<br />

and the other Subfeed options.<br />

125A<br />

Vert.<br />

ED <br />

125A<br />

Horiz.<br />

CED<br />

225A<br />

Horiz.<br />

QR<br />

56 33 — — 33 — — 33 — — — n/a — n/a n/a n/a<br />

62 39 33 33 39 33 33 39 33 — — n/a — n/a n/a n/a<br />

68 45 39 39 45 39 39 45 39 33 — n/a — n/a n/a n/a<br />

74 45 45 45 45 45 45 45 45 39 33 n/a 33 n/a n/a n/a<br />

[90p] [90p] [90p] [90p] [90p] [90p] [90p] [90p] [78p] [66p] n/a [66p] n/a n/a n/a<br />

Note: The vertical main breaker application for ED, QJ, QR, and FD adds 6" of box height.<br />

225A<br />

Vert.<br />

QR <br />

250A<br />

Horiz.<br />

FD<br />

250A<br />

Vert.<br />

FD <br />

250A<br />

Vert.<br />

CFD<br />

400A<br />

Vert.<br />

JD<br />

400A<br />

Vert.<br />

JD<br />

400A<br />

Vert.<br />

CJD<br />

400A<br />

Vert.<br />

CJD<br />

600A<br />

Vert.<br />

LD<br />

600A<br />

Vert.<br />

LD<br />

600A<br />

Vert.<br />

CLD<br />

n In general, vertically mounted mains<br />

require 6" more box space than<br />

equivalent horizontally mounted<br />

mains.<br />

n Neutral configuration supports a<br />

maximum of 90 1-pole breakers.<br />

600A<br />

Vert.<br />

CLD<br />

Main lug wire<br />

bending space<br />

diagram<br />

Main breaker<br />

wire bending<br />

space diagram<br />

Box depth = 5.75 in.<br />

(146 mm)<br />

Box width = 20 in.<br />

(508 mm)<br />

for 100-600A<br />

Box depth = 5.75 in.<br />

(146 mm)<br />

Box width = 20 in.<br />

(508 mm)<br />

for 100-600A<br />

11-28<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Panelboards<br />

Type P2 Panelboards<br />

Revised on 05/15/18<br />

Selection/Dimensions<br />

Standard Circuit P2 Panels<br />

Main Breaker Wire Bending<br />

Standard Circuits (up to 54 1" module branch poles)<br />

Panel Amps Breaker Frames C D <br />

100<br />

BL 5.75 8.00<br />

BQD 5.13 8.00<br />

xGB, xGB2 4.63 8.00<br />

125<br />

ED (horiz.) 4.00 8.00<br />

ED (vert.) 6.56 11.13<br />

225<br />

QR (horiz.) 5.00 7.00<br />

QR (vert.) 10.06 16.69<br />

250<br />

FD (horiz.) 5.00 7.00<br />

FD (vert.) 13.25 22.72<br />

400 JD 15.38 25.00<br />

600 LD 15.38 23.00<br />

Extended Circuit P2 Panels<br />

Main Breaker Wire Bending<br />

Extended Circuits (more than 54 1" module branch poles)<br />

Panel Amps Breaker Frames C D <br />

100<br />

BL 5.75 6.56<br />

BQD 5.13 6.56<br />

xGB, xGB2 4.63 6.56<br />

125<br />

ED (horiz.) 4.00 6.56<br />

ED (vert.) 12.56 14.88<br />

225<br />

QR (horiz.) 5.00 6.44<br />

QR (vert.) 10.06 15.53<br />

250<br />

FD (horiz.) 5.00 5.63<br />

FD (vert.) 19.25 25.71<br />

400 JD 15.38 23.75<br />

600 LD (54p max) N/A N/A<br />

11 PANELBOARDS<br />

Main Lug Connectors<br />

Standard Circuits (up to 54 1" module branch poles)<br />

Panel Amps Standard Connectors C D <br />

125 (1) #14-2/0 6.62 8.19<br />

250 (1) #6 AWG - 350 MCM 11.75 10.72<br />

400<br />

(1) #4 AWG - 600 MCM 14.00 13.09<br />

or (2) #6 - 250 MCM<br />

600 (2) #4 AWG - 500 MCM 14.00 11.00<br />

Main Lug Connectors<br />

Extended Circuits (more than 54 1" module branch poles)<br />

Panel Amps Standard Connectors C D <br />

125 (1) #14-2/0 12.62 8.91<br />

250 (1) #6 AWG - 350 MCM 17.75 13.69<br />

400<br />

(1) #4 AWG - 600 MCM 14.00 14.19<br />

or (2) #6 - 250 MCM<br />

600 (2) #4 AWG - 500 MCM 14.00 14.23<br />

Branch Breaker Side Gutters Inches (mm)<br />

Reference<br />

Letter Panel Width 20" (508)<br />

A 5.750 (146)<br />

B 5.125 (130)<br />

C 4.000 (102)<br />

D 5.000 (127)<br />

E 4.625 (117)<br />

A<br />

BL, BLH, HBL<br />

BL, BLH, HBL<br />

BLF2, BLHF2,<br />

BLF2, BLHF2,<br />

A<br />

B<br />

HBLF2, BLFB, BLHFB HBLF2, BLFB, BLHFB<br />

B<br />

BQD, BQD6 c<br />

BQD, BQD6 c<br />

C<br />

ED4, ED6<br />

ED4, ED6<br />

HED4, HHED6<br />

HED4, HHED6<br />

C<br />

QR2, QRH2, HQR2, HQR2H<br />

D<br />

(Single Mounted)<br />

D<br />

NGB, HGB, LGB NGB, HGB, LGB<br />

E E<br />

NGB2, HGB2, LGB2 NGB2, HGB2, LGB2<br />

Panel Width<br />

20 in. (508 mm)<br />

Refer to diagrams at the bottom of page 11-28.<br />

Single branch mounting construction.<br />

c BQD6 is not UL Listed. Only for CUL and CSA panels.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-29


Panelboards<br />

Type P2 Panelboards<br />

Revised on 04/30/19<br />

Selection<br />

11<br />

PANELBOARDS<br />

Main Breaker Selection a<br />

Amp<br />

Rating<br />

100<br />

125<br />

225<br />

250<br />

400<br />

600<br />

Breaker<br />

Type<br />

Max. Interrupting Rating (kA)<br />

240V 480V 600V<br />

Ref.<br />

Type<br />

Code<br />

Horizontal<br />

or Vertical<br />

Available Trip Values<br />

BL 10 — — BL H 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100<br />

HBL 65 — — HB H 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100<br />

BQD 65 14 — BQ H 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100<br />

BLH 22 — — BH H 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100<br />

NGB 100 25 14 NB H 50, 60, 70, 80, 90, 100, 110, 125<br />

HGB 100 35 14 G2 H 50, 60, 70, 80, 90, 100, 110, 125<br />

LGB 100 65 14 G3 H 50, 60, 70, 80, 90, 100, 110, 125<br />

ED4 65 18 — E4 H/V 50, 60, 70, 80, 90, 100, 110, 125<br />

ED6 e 100 25 14 E6 H/V 60, 70, 80, 90, 100, 110, 125 (3-pole)<br />

HED4 100 42 — H4 H/V 50, 60, 70, 80, 90, 100, 110, 125<br />

CED6 b 200 200 100 CE H/V 50, 60, 70, 80, 90, 100, 110, 125<br />

NGB2 100 25 14 G4 H 50, 60, 70, 80, 90, 100, 110, 125<br />

HGB2 100 35 22 G5 H 50, 60, 70, 80, 90, 100, 110, 125<br />

LGB2 100 65 25 G6 H 50, 60, 70, 80, 90, 100, 110, 125<br />

QR2 10 — — QR H 100, 110, 125, 150, 175, 200, 225<br />

QRH2 25 — — Q4 H 100, 110, 125, 150, 175, 200, 225<br />

HQR2 65 — — Q5 H 100, 110, 125, 150, 175, 200, 225<br />

HQR2H 100 — — Q6 H 100, 110, 125, 150, 175, 200, 225<br />

FD6 65 35 18 FD H/V 70, 80, 90, 100, 110, 125, 150, 175, 200, 225<br />

FXD6 65 35 18 FX H/V 70, 80, 90, 100, 110, 125, 150, 175, 200, 225<br />

HFD6 100 65 25 HF H/V 70, 80, 90, 100, 110, 125, 150, 175, 200, 225<br />

HFXD6 100 65 25 H2 H/V 70, 80, 90, 100, 110, 125, 150, 175, 200, 225<br />

CFD6 b 200 200 100 CF H/V 70, 80, 90, 100, 110, 125, 150, 175, 200, 225<br />

FD6 65 35 18 FD H/V 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250<br />

FXD6 65 35 18 FX H/V 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250<br />

HFD6 100 65 35 HF H/V 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250<br />

HFXD6 65 35 25 H2 H/V 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250<br />

JXD6 b 65 35 25 JX V 200, 225, 250, 300, 350, 400<br />

JD6 b 65 35 35 J6 V 200, 225, 250, 300, 350, 400<br />

HJXD6 b 100 65 35 H6 V 200, 225, 250, 300, 350, 400<br />

HJD6 b 100 65 35 H5 V 200, 225, 250, 300, 350, 400<br />

SJD6 b 65 35 25 SJ V 200, 300, 400<br />

SHJD6 b 100 65 35 S2 V 200, 300, 400<br />

CJD6 b 200 200 100 CJ V 200, 300, 400<br />

SCJD6 b 200 200 100 SC V 200, 300, 400<br />

LXD6 b 65 35 25 LX V 450, 500, 600<br />

LD6 b 65 35 25 L6 V 250, 300, 350, 400, 450, 500, 600<br />

HLXD6 b 100 65 35 HL V 250, 300, 350, 400, 450, 500, 600<br />

HLD6 b 100 65 35 HO V 250, 300, 350, 400, 450, 500, 600<br />

SLD6 b 65 35 25 SL V 300, 400, 500, 600<br />

SHLD6 b 100 65 35 S6 V 300, 400, 500, 600<br />

CLD6 b 200 150 100 CL V 300, 400, 500, 600<br />

SCLD6 200 150 100 C6 V 300, 400, 500, 600<br />

When an ED4, ED6,<br />

HED4, HHED6, QR2,<br />

QRH2, HQR2, HQR2H,<br />

FD6, HFD6, or FXD6<br />

frame main breaker is<br />

required to be vertically<br />

mounted, pricing will<br />

typically be higher.<br />

Vertically Mounted Main Breaker (available in 2-pole or 3-pole)<br />

Additional<br />

Ampere Rating Breaker Type(s)<br />

Unit Space (in.)<br />

125 ED4, ED6 e , HED4, HHED6 6<br />

225 QR2, QRH2, HQR2, HQR2H 6<br />

250 FXD6, FD6, HFD6 6<br />

Subfeed Breakers (available in 2-pole or 3-pole)<br />

Mounting Position When Ampere Maximum Interrupting Rating<br />

Breaker Used as Subfeed Breaker Ratings (kA) Symmetrical<br />

Type<br />

Vertical For Load 240V AC 480V AC 600V AC<br />

FD6 c , FXD6 Twin 70–250 65 35 22<br />

HFD6 c , HFXD6 Twin 70–250 100 65 25<br />

JD6 d , JXD6 Single 200–400 65 35 25<br />

HJD6 d , HJXD6 Single 200–400 100 65 35<br />

a Interchangeable trip main breakers are mounted at top<br />

of panel only.<br />

b Vertically mounted.<br />

c Twin mounted subfeed breakers are mounted at the<br />

bottom of panelboard only and adds 24" to the panel<br />

height.<br />

d Subfeed breaker is mounted at bottom of panelboard<br />

only. 400 amp subfeed breaker adds 24" to the panel<br />

height. (Only for use with MLO)<br />

e ED6/CED6 2-pole limited amps available (20-50A)<br />

11-30<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category UNPB


Panelboards<br />

Type P2 Panelboards<br />

Revised on 04/30/19<br />

Selection<br />

P2 Branch Circuit Breakers<br />

Amp<br />

Rating<br />

100<br />

xx<br />

125<br />

225<br />

Trip<br />

Type<br />

Thermal<br />

Magnetic<br />

Breaker<br />

Family<br />

BL<br />

Special BLG<br />

Application BL<br />

Thermal<br />

Magnetic<br />

BQD<br />

Electronic<br />

and misc.<br />

Thermal<br />

Magnetic<br />

Thermal<br />

Magnetic<br />

BL<br />

GB<br />

Sentron<br />

GB2<br />

3VA41 c<br />

QR<br />

Breaker<br />

Type<br />

1-Pole<br />

Max IR (kA) at<br />

120V 277V 347V<br />

125V<br />

DC<br />

Amp<br />

Ratings<br />

Avail.<br />

2-Pole and 3-Pole<br />

Max IR (kA) at<br />

120/<br />

240V<br />

240V<br />

480Y/<br />

277V<br />

480V<br />

600Y/<br />

347V<br />

600V<br />

125/<br />

250V<br />

DC<br />

250V<br />

DC<br />

Amp<br />

Ratings<br />

Avail.<br />

S = Single Mount<br />

S<br />

T = Twin mount<br />

T<br />

Unit Max<br />

Space 1-pole<br />

per Kit Circuits<br />

(in.) per Kit<br />

BL 10 — — — 15-70 10 10 — — — — — — 15-100 — T 3.00 6<br />

BLH 22 — — — 15-70 22 22 — — — — — — 15-100 — T 3.00 6<br />

HBL 65 — — — 15-50 65 65 — — — — — — 15-100 — T 3.00 6<br />

BLG a 10 — — — 15-20 10 — — — — — — — 30 — T 3.00 6<br />

BL (HID) 10 — — — 15-30 10 — — — — — — — 15-30 — T 3.00 6<br />

BQD e 65 14 — 14 15-100 — 65 14 — — — 14 — 15-100 — T 3.00 6<br />

BQD6 f 65 — — 14 15-70 — 65 — 10 — 14 — 15-70 — T 3.00 6<br />

AFCI/<br />

GFCI<br />

& Dual<br />

Function<br />

x — — —<br />

see<br />

special<br />

table<br />

page<br />

11-13<br />

x — — — — — — —<br />

see<br />

special<br />

table<br />

page<br />

11-13<br />

— T 3.00 6<br />

NGB 100 25 14 14 15-125 — 100 25 — 14 — 14 — 15-125 — T 3.00 6<br />

HGB 100 35 14 14 15-125 — 100 35 — 14 — 14 — 15-125 — T 3.00 6<br />

LGB 100 65 14 14 15-125 — 100 65 — 14 — 14 — 15-125 — T 3.00 6<br />

ED4 65 22 — 30 15-100 — 65 — 18 — — — 30 15-125 — T 3.00 6<br />

ED6 g — — — 15-100 — 65 — 25 — 18 — 30 20-125 — T 3.00 6<br />

HED4 b 100 25 b — 30 15-100 — 65 — 18 b — — — 30 15-125 — T 3.00 6<br />

HHED6 — — — — — — 100 — 65 — 18 — — 15-50 — T 3.00 6<br />

NGB2 100 25 14 14 d 15-125 — 100 — 25 14 — 14 d — 15-125 — T 3.00 6<br />

HGB2 100 35 22 14 d 15-125 — 100 — 35 22 — 14 d — 15-125 — T 3.00 6<br />

LGB2 100 65 25 14 d 15-125 — 100 — 65 25 — 14 d — 15-125 — T 3.00 6<br />

info not x x x x x x x — x — — x — T 3.00 6<br />

yet available<br />

x x x x x x x — x — — x — T 3.00 6<br />

x x x x x x x — x — — x — T 3.00 6<br />

QR2 — — — — — — 10 — — — — — — 100-225 — T 6.00 3<br />

QRH2 — — — — — — 25 — — — — — — 100-225 — T 6.00 3<br />

HQR2 — — — — — — 65 — — — — — — 100-225 — T 6.00 3<br />

HQR2H — — — — — — 100 — — — — — — 100-225 — T 6.00 3<br />

11 PANELBOARDS<br />

Branch Neutral Connections<br />

Wire Range Max. Number of Connections Max. Amp h<br />

#14-#6 26 65<br />

#14-1/0 28 125<br />

#6-350 kcmil 3 250<br />

(1) #4-600 kcmil<br />

or (2) #6-250 kcmil<br />

1 400<br />

a BLG two-pole breaker is one phase and neutral. Three<br />

pole is two phases and neutral - See SpeedFax page 7-31<br />

b 1-pole HED4 15-30A rated 65kA; 35-100A rated 25kA:<br />

3-pole HED4 rated 42kA<br />

c Availability and additional specs tbd, expected late<br />

2019. (COMPAS may allow selection of alternate trip<br />

units)<br />

d 2-pole only or two outer poles of 3-pole breaker<br />

e Approved for CSA and UL Listed.<br />

f Approved for CSA but not UL Listed.<br />

g ED6 2-pole only available in 20A, 25A and 30A. ED6<br />

1-pole not UL listed - See SpeedFAX section 7 for more<br />

details.<br />

h Based on 75 degree copper.<br />

Product Category PBSB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-31


Panelboards<br />

Type P2 Panelboards<br />

Revised on 05/01/17<br />

Selection<br />

11<br />

PANELBOARDS<br />

Main Lugs Only — Examples of basic P2 Panel numbers w/o devices that add to box height.<br />

Max Max. Min. Standard or<br />

3Ø4W 208Y/120V<br />

1Ø3W 120/240V<br />

3Ø4W 480Y/277V<br />

Panel Amp 1-pole Unit Extended<br />

Box Height<br />

Box Height<br />

Box Height<br />

Rating Circuits space Circuit Panel Number Inches Min. Panel Number Inches Min. Panel Number Inches Min.<br />

18 9 Standard P2C18ML125ATS 26 P2A18ML125ATS 26 P2E18ML125ATS 26<br />

30 15 Circuit P2C30ML125ATS 32 P2A30ML125ATS 32 P2E30ML125ATS 32<br />

42 21 Panel P2C42ML125ATS 38 P2A42ML125ATS 38 P2E42ML125ATS 38<br />

125<br />

54 27 P2C54ML125ATS 44 P2A54ML125ATS 44 P2E54ML125ATS 44<br />

66 33 Extended P2C66ML125ATS 56 P2A66ML125ATS 56 P2E66ML125ATS 56<br />

78 39 Circuit P2C78ML125ATS 62 P2A78ML125ATS 62 P2E78ML125ATS 62<br />

90 45 Panel P2C90ML125ATS 68 P2A90ML125ATS 68 P2E90ML125ATS 68<br />

18 9 Standard P2C18ML250ATS 32 P2A18ML250ATS 32 P2E18ML250ATS 32<br />

30 15 Circuit P2C30ML250ATS 38 P2A30ML250ATS 38 P2E30ML250ATS 38<br />

42 21 Panel P2C42ML250ATS 44 P2A42ML250ATS 44 P2E42ML250ATS 44<br />

250<br />

54 27 P2C54ML250ATS 50 P2A54ML250ATS 50 P2E54ML250ATS 50<br />

66 33 Extended P2C66ML250ATS 62 P2A66ML250ATS 62 P2E66ML250ATS 62<br />

78 39 Circuit P2C78ML250ATS 68 P2A78ML250ATS 68 P2E78ML250ATS 68<br />

90 45 Panel P2C90ML250ATS 74 P2A90ML250ATS 74 P2E90ML250ATS 74<br />

18 9 Standard P2C18ML400ATS 38 P2A18ML400ATS 38 P2E18ML400ATS 38<br />

30 15 Circuit P2C30ML400ATS 44 P2A30ML400ATS 44 P2E30ML400ATS 44<br />

42 21 Panel P2C42ML400ATS 50 P2A42ML400ATS 50 P2E42ML400ATS 50<br />

400<br />

54 27 P2C54ML400ATS 56 P2A54ML400ATS 56 P2E54ML400ATS 56<br />

66 33 Extended P2C66ML400ATS 62 P2A66ML400ATS 62 P2E66ML400ATS 62<br />

78 39 Circuit P2C78ML400ATS 68 P2A78ML400ATS 68 P2E78ML400ATS 68<br />

90 45 Panel P2C90ML400ATS 74 P2A90ML400ATS 74 P2E90ML400ATS 74<br />

18 9 Standard P2C18ML600ATS 38 P2A18ML600ATS 38 P2E18ML600ATS 38<br />

30 15 Circuit P2C30ML600ATS 44 P2A30ML600ATS 44 P2E30ML600ATS 44<br />

42 21 Panel P2C42ML600ATS 50 P2A42ML600ATS 50 P2E42ML600ATS 50<br />

600<br />

54 27 P2C54ML600ATS 56 P2A54ML600ATS 56 P2E54ML600ATS 56<br />

66 33 Extended P2C66ML600ATS 62 P2A66ML600ATS 62 P2E66ML600ATS 62<br />

78 39 Circuit P2C78ML600ATS 68 P2A78ML600ATS 68 P2E78ML600ATS 68<br />

90 45 Panel P2C90ML600ATS 74 P2A90ML600ATS 74 P2E90ML600ATS 74<br />

Main Circuit Breaker — Examples of Panel numbers w/o options that add to box height.<br />

Max Main Max.<br />

Standard<br />

1Ø3W 120/240V<br />

3Ø4W 208Y/120V<br />

3Ø4W 480Y/277V<br />

Panel Amp Type 1-pole Unit or<br />

Box Height<br />

Box Height<br />

Box Height<br />

Rating ref Circuits space Extended Panel Number Inches Min. Panel Number Inches Min. Panel Number Inches Min.<br />

100 BL/BQD, 18 9 Standard P2A18BL100ATS 26 P2C18BL100ATS 26 P2E18BQ100ATS 26<br />

xGB, 30 15 Circuit P2A30BL100ATS 32 P2C30BL100ATS 32 P2E30BQ100ATS 32<br />

ED horiz. 42 21 Panel P2A42BL100ATS 38 P2C42BL100ATS 38 P2E42BQ100ATS 38<br />

54 27 P2A54BL100ATS 44 P2C54BL100ATS 44 P2E54BQ100ATS 44<br />

125 Horiz. 18 9 Standard P2A18BQ125ATS 26 P2C18NB125ATS 26 P2E18E4125ATS 26<br />

Main a 30 15 Circuit P2A30BQ125ATS 32 P2C30NB125ATS 32 P2E30E4125ATS 32<br />

42 21 Panel P2A42BQ125ATS 38 P2C42NB125ATS 38 P2E42E4125ATS 38<br />

BQD, 54 27 P2A54BQ125ATS 44 P2C54NB125ATS 44 P2E54E4125ATS 56<br />

xGB, ED 66 33 Extended P2A66BQ125ATS 56 P2C66NB125ATS 56 P2E66E4125ATS 56<br />

78 39 Circuit P2A78BQ125ATS 62 P2C78NB125ATS 62 P2E78E4125ATS 62<br />

90 45 Panel P2A90BQ125ATS 68 P2C90NB125ATS 68 P2E90E4125ATS 68<br />

225 Horiz. 18 9 Standard P2A18QR225ATS 32 P2C18QR225ATS 32 P2E18FX225ATS 38<br />

Main b 30 15 Circuit P2A30QR225ATS 38 P2C30QR225ATS 38 P2E30FX225ATS 44<br />

42 21 Panel P2A42QR225ATS 44 P2C42QR225ATS 44 P2E42FX225ATS 50<br />

QR, FD 54 27 P2A54QR225ATS 50 P2C54QR225ATS 50 P2E54FX225ATS 56<br />

(225A 66 33 Extended P2A66QR225ATS 56 P2C66QR225ATS 56 P2E66FX225ATS 68<br />

max.)<br />

78 39 Circuit P2A78QR225ATS 62 P2C78QR225ATS 62 P2E78FX225ATS 74<br />

90 45 Panel P2A90QR225ATS 68 P2C90QR225ATS 68 n/a n/a<br />

250 Horiz. 18 9 Standard P2A18FX250ATS 38 P2C18FX250ATS 38 P2E18FX250ATS 38<br />

Main c 30 15 Circuit P2A30FX250ATS 44 P2C30FX250ATS 44 P2E30FX250ATS 44<br />

42 21 Panel P2A42FX250ATS 50 P2C42FX250ATS 50 P2E42FX250ATS 50<br />

FD<br />

54 27 P2A54FX250ATS 56 P2C54FX250ATS 56 P2E54FX250ATS 56<br />

66 33 Extended P2A66FX250ATS 68 P2C66FX250ATS 68 P2E66FX250ATS 68<br />

78 39 Circuit P2A78FX250ATS 74 P2C78FX250ATS 74 P2E78FX250ATS 74<br />

90 45 Panel n/a n/a n/a n/a n/a n/a<br />

400 Vert. JD 18 9 Standard P2A18JX400ATS 50 P2C18JX400ATS 50 P2E18JX400ATS 50<br />

Main d 30 15 Circuit P2A30JX400ATS 56 P2C30JX400ATS 56 P2E30JX400ATS 56<br />

42 21 Panel P2A42JX400ATS 62 P2C42JX400ATS 62 P2E42JX400ATS 62<br />

54 27 P2A54JX400ATS 68 P2C54JX400ATS 68 P2E54JX400ATS 68<br />

66 33 Extended P2A66JX400ATS 74 P2C66JX400ATS 74 P2E66JX400ATS 74<br />

600 Vert. LD 18 9 Standard P2A18LX600ATS 56 P2C18LX600ATS 56 P2E18LX600ATS 56<br />

Main e 30 15 Circuit P2A30LX600ATS 62 P2C30LX600ATS 62 P2E30LX600ATS 62<br />

42 21 Panel P2A42LX600ATS 68 P2C42LX600ATS 68 P2E42LX600ATS 68<br />

54 27 P2A54LX600ATS 74 P2C54LX600ATS 74 P2E54LX600ATS 74<br />

General Note: Panel numbers and box sizes are for<br />

reference only - COMPAS will configure proper<br />

box size needed based on all options.<br />

a 125A: for vert ED & horiz. CED add 6" of box height for<br />

both Standard and Extended Circuit.<br />

b 225A: for vert QR & FD add 6" of box height for Standard<br />

Circuit. Add 12" of box height for Extended Circuit FD<br />

Horizontal.<br />

c 250A: for vert FD add 6" of box height; for vert CFD<br />

add 12" of box height. (Standard Circuit- see chart for<br />

Extended Circuit)<br />

d 400A: for CJD add 12" of box height for Standard Circuit.<br />

e 600A: for CLD add 6" of box height for Standard Circuit.<br />

11-32<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category PBSB


Panelboards<br />

Type P2 Panelboard Modifications and Additions<br />

Revised on 04/11/17<br />

Selection<br />

Enclosures<br />

Extra Gutter to Sides or Ends<br />

of the Can (Type 1 Only)<br />

Description<br />

6" end gutter<br />

2" side gutter<br />

Barrier in gutter (add to extra<br />

gutter price – min 4" required)<br />

24" wide<br />

Hinged trims<br />

Piano hinged trims<br />

Door-in-door trims<br />

Screw to the box trims<br />

Trim mounted devices . . . . . See page 11-104<br />

• Pilot lights<br />

• Toggle switches<br />

• Push buttons<br />

Painted boxes . . . . . . . . . . . . See page 11-104<br />

Custom colors . . . . . . . . . . See painted boxes<br />

Increase gauge trims<br />

and boxes . . . . . . . . . . . . . . See page 11-104<br />

Stainless steel trims<br />

and boxes, Type 1 . . . . . . . See page 11-104<br />

Meters<br />

(Contact sales for pricing and application<br />

engineering for space requirements)<br />

Panel Skirts See page 11-105<br />

Special Locks<br />

TEY<br />

TEU1<br />

Cat 60<br />

LL803<br />

LL806<br />

Yale 47 (NYC)<br />

National C413A<br />

Best Lock 7-pin tumbler<br />

Southco 1/4 Fastener<br />

Corbin 1001 FAB7<br />

Panel Bus Modifications<br />

Catalog Number Addition<br />

Amperes Ratings<br />

Main Bus<br />

125A 250A 400A 600A<br />

750 A/SI AL. B B B B<br />

Copper (tin pltd.) F F F F<br />

Copper (silver E E E E<br />

pltd.)<br />

1000 A/SI Copper G G G G<br />

(tin pltd.)<br />

1000 A/SI Copper<br />

(silver pltd.)<br />

H H H H<br />

Subfeed, Feed-Thru and Split<br />

Bus (for 2-pole or 3-pole)<br />

Ampere<br />

Rating<br />

Connector<br />

Cu/Al Wire Range<br />

Feed-Thru Lugs — Cannot Be Used<br />

in Conjunction with TVSS or Subfeed<br />

Breakers (200% Neutral not available)<br />

(1)—#12 AWG-2/0<br />

100/125<br />

6<br />

kcmil<br />

(1)—#6 AWG-350<br />

225/250<br />

6<br />

kcmil<br />

(2)—250 kcmil<br />

400<br />

9<br />

(1)—600 kcmil<br />

600 (2)—250-500 kcmil 12<br />

Split Bus (1 per interior)<br />

Requires feed thru lugs also to feed sub<br />

panel section and for space requirements.<br />

(1)—#12 AWG-2/0<br />

100/125<br />

6<br />

kcmil<br />

(1)—#6 AWG-350<br />

225/250<br />

6<br />

kcmil<br />

(2)—250 kcmil<br />

400<br />

6<br />

(1)—600 kcmil<br />

600 (2)—250-500 kcmil 6<br />

Contactor Mains or Submain*<br />

See Page 11-103<br />

• Asco 920 through 225 amps – adds<br />

12" unit space as main, 15" unit<br />

space as submain<br />

• External with manufacture supplied<br />

enclosure<br />

• Siemens LEN through 30 amps - adds 6" as<br />

main; 18" for up to 100A submain and 21"<br />

for 200A. 7.75" depth cans for up to 100A<br />

and 10" depth cans for 200A.<br />

*Call plant for correct can size.<br />

Branch and Main Breaker Accessories<br />

See breaker section of this catalog.<br />

• Handle blocks<br />

• Handle locks<br />

• Aux. Contacts 1<br />

• UVR a<br />

Unit<br />

Space<br />

(inches)<br />

Subfeed (Double) Lugs for Main Lug<br />

Panelboards Only (400 max)<br />

100/125<br />

(2)—#12 AWG-2/0<br />

kcmil<br />

6<br />

225/250<br />

(2)—#6 AWG-350<br />

kcmil (custom)<br />

6<br />

400<br />

(4)—250 kcmil<br />

(custom)<br />

(2)—600 kcmil<br />

6<br />

Increase Capacity Neutral up to 200%<br />

(N/A on Feed Thru Lugs & Subfeed Lugs)<br />

Main Bus Amps<br />

125<br />

250<br />

400<br />

600<br />

Copper MLO Only<br />

Main Bus Amps<br />

125 250 400 600<br />

Bus mounted SPD See Section 10<br />

Service Entrance Label<br />

Type P2 Panelboards are factory labeled<br />

suitable for use as service entrance<br />

equipment when NEC requirements are met.<br />

A panelboard cannot have more than six<br />

main disconnects, unless it is a lighting and<br />

appliance branch panelboard. Lighting and<br />

appliance branch panelboards are limited to<br />

two main disconnects. Factory installed and<br />

Field installable Service Entrance Barrier kits<br />

are now available as required by UL67 (In<br />

COMPAS, you must select Service Entrance<br />

Required).<br />

Grounding of Panelboards<br />

Ground Bars except for brazed to box are<br />

shipped with the panel interior not factory<br />

mounted.<br />

• Non-Insulated Equipment Ground Bar<br />

• Copper Non-Insulated Ground Bar<br />

• Al Insulated Equipment Ground Bar<br />

• Cu Insulated Equipment Ground Bar<br />

• Ground Bar Brazed to Box<br />

(Not recommended for painted or<br />

NEMA 3R enclosures)<br />

Shunt Trip on Main or Branch<br />

BL, BLH, HBL, NGB, HGB, LGB, NGB2,<br />

HGB2, LGB2, ED4, HED4, HHED6 uses<br />

1" unit space for shunt trip. All others<br />

may be used on mains or subfeeds. See<br />

breaker section for list price adders.<br />

Time Clocks<br />

Time clocks may be mounted in a 23"<br />

enclosure to be cable connected to the<br />

panel. Sangamo, Tork or Paragon time<br />

clock can be supplied and mounted in<br />

panelboard cabinet. Adds 12" to panel<br />

height. Mounts in Sub-area.<br />

Description<br />

Time Clock (1 or 2-pole, single or double<br />

throw contacts; 3-pole, single throw)<br />

277V maximum with plain dial<br />

Astronomical dial<br />

An omitting device<br />

Reserve power or carryover<br />

Space and mounting<br />

provisions only<br />

11 PANELBOARDS<br />

a Accessories on 1" pole breakers<br />

(BL, BQD, ED) will take unit space.<br />

See page 11-36 for unit space adders and<br />

compatibility with other options.<br />

(Devices mounted and wired to the trim<br />

should also have hinged trim specified)<br />

Product Category PBSB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-33


Panelboards<br />

Revised on 04/30/19<br />

Embedded Micro Metering Module (Type P2 Panelboard)<br />

Selection<br />

11<br />

PANELBOARDS<br />

SEM3 System configured in Panelboards<br />

The Siemens SEM3 system can be configured for factory<br />

installation in branch circuit monitoring applications using the<br />

Siemens COMPAS configuration tool. This option can lower<br />

the installation time of the system for the installer while providing<br />

a factory warrantied solution.<br />

The SEM3 system can be factory installed in unit space in<br />

type P2, P4, & P5 Siemens panel boards and SB1, SB2, &<br />

SB3 type Siemens switchboards. Please note P1 and P3<br />

configurations are not available at this time and the amount<br />

of unit space needed varies depending upon the application.<br />

Please note that lead time adders will apply and may vary<br />

depending upon the configuration of the system.<br />

SEM3 for use in Siemens Panelboards<br />

Type P2: Enclosure<br />

• Available in a NEMA 1, 3R, or 12 rated enclosure.<br />

• Minimum width & depth: 24” width x 5.75” depth<br />

• Height: Up to 74" depending on branch breaker selection<br />

– Addition of monitoring on some mains (primary and subfeed) may require additional box<br />

length. In these cases the box will be increased to the next size available as a standard<br />

design.<br />

– In cases where enclosure size is increased all multi-section panels will be increased to<br />

match the largest section.<br />

Controller<br />

SEM3 controller is mounted in unit space opposite of the feed location specified in COMPAS<br />

(i.e., bottom mount for top feed) and will require 3” of unit space. Each controller will be powered<br />

by direct tap connection to the panel section bus. Each controller can monitor up to 45<br />

circuits. Applications that require monitoring more than 45 circuits will require additional controllers.<br />

Current Transformers (CTs)<br />

Five sizes of CTs are available for use in the P2 panel: 50, 125, 250, 400 & 600 amp. All CTs<br />

are pre-mounted to a support bracket that attaches to the base rail of the interior of the panel<br />

board. Each bracket supports a maximum of 3 CTs and is designed for the breaker selected<br />

(brackets are not interchangeable between breaker frames). Each CT will be attached to a data<br />

module that is placed in the meter racks.<br />

Meter Racks<br />

Each meter rack requires 3” of unit space. All meter racks will be installed next to the SEM3<br />

controller in unit space. The COMPAS configuration tool will select the appropriate meter rack<br />

configuration according to the user’s application and will use the 21 space meter rack as a<br />

default option where possible. Only one meter rack (regardless of number of positions) can be<br />

installed in 3” of unit space.<br />

NOTE: Monitoring of 45 circuits will require 9" of unit space: two 21 position racks and one 3 position<br />

rack<br />

11-34<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Panelboards<br />

Embedded Micro Metering Module (Type P2 Panelboard)<br />

Selection<br />

P2 Devices<br />

Enclosure sizes<br />

Example P2 Panel with SEM3 Type 1 Enclosure (24" Wide x 5.75" Deep)<br />

Enclosure heights are in 6" increments from 26" thru 74".<br />

Enclosure heights: 26", 32", 38", 44", 50", 56", 62", 68", 74"<br />

The COMPAS configuration tool can provide actual dimensions based on the configuration.<br />

Example below is largest standard P2 enclosure for factory assembled panel<br />

with all small (1") branch breakers installed.<br />

24" std. width<br />

11 PANELBOARDS<br />

Main Breaker / Main Lug space<br />

varies based on selected options<br />

Unit space varies<br />

based on selected options<br />

Note: All circuits do not have to be monitored<br />

by SEM3 - user can select any circuits in this<br />

space to be monitored.<br />

Based on smallest branch breakers and a<br />

3-phase main being monitored.<br />

There is a maximum of 63 circuits that can be<br />

monitored with the configuration shown.<br />

Some selections of main breakers and<br />

other subfeed options could limit this further.<br />

In this situation there is 30" of unit space available -<br />

so 60 branch circuits could be monitored.<br />

If monitoring the main three additional circuits could<br />

be monitored with a total of 63 circuits.<br />

This requires two controllers and three 21 position<br />

racks using 15" of unit space.<br />

- see below -<br />

SEM3 space varies by number of circuits<br />

monitored - this uses unit space.<br />

== > 6" of space for up to 21 circuits monitored<br />

one controller and one 21-pos rack<br />

== > 9" of space for up to 42 circuits monitored<br />

one controller and two 21-pos racks<br />

== > 12" of space for up to 45 circuits monitored<br />

one controller and two 21-pos racks plus one 3-pos rack<br />

== > 15" of space for up to 63 circuits monitored<br />

two controllers and three 21-pos racks<br />

Note: If subfeed space is needed - it will take<br />

away from available unit space.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-35


Panelboards<br />

Type P2 Panelboard Standard Modifications and Additions<br />

Revised on 04/30/19<br />

Selection<br />

11<br />

PANELBOARDS<br />

Box Size Additions for Optional Features<br />

Main Lugs<br />

Main Breakers<br />

125A<br />

Horiz. 125A 125A 225A 225A 225A 250A 250A 400A 400A 600A 600A<br />

BL, BQD, Horiz. Vert. Horiz. Vert. Horiz. Vert. Vert. Vert. Vert. Vert. Vert.<br />

Options<br />

125A 250A 400A 600A ED, xGB CED ED QR QR FD FD CFD JD CJD LD CLD<br />

*Min. Box Size 26" 32" 38" 38" 26" 32" 32" 32" 38" 38" 44" 50" 50" 62" 56" 62"<br />

200% Neutral<br />

(lug type)<br />

0 0 6 (all) 6 (all) 0 0 0 N/A 0 N/A 0 0 0 0 0 0<br />

Std. Lugs<br />

(100% Neut. PNL)<br />

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0<br />

CU Lugs<br />

(100% Neut. PNL)<br />

6 6 6 0 N/A N/A 0 N/A 0 N/A 0 0 0 0 0 0<br />

Comp Lugs<br />

(100% Neut. PNL)<br />

6 6 6 6 N/A N/A 0 N/A 0 N/A 0 0 0 0 0 0<br />

Feed-thru<br />

Standard Lugs<br />

6 6 12 12 6 6 6 N/A 6 N/A 6 6 12 12 12 12<br />

Feed-thru Cu Lugs 6 6 12 N/A N/A N/A 6 N/A 6 N/A 6 6 12 12 N/A N/A<br />

Feed-thru<br />

Comp Lugs<br />

6 12 12 N/A N/A N/A 6 N/A 6 N/A 12 12 12 12 N/A N/A<br />

Subfeed Standard<br />

Lugs<br />

0 6 6 N/A — — — — — — — — N/A — — —<br />

Split Bus 6 6 6 6 6 6 6 N/A 6 N/A 6 6 6 6 6 6<br />

(1) FD Subfeed<br />

(Horizontal Mtg.)<br />

N/A 12 12 12 N/A N/A N/A N/A N/A 12 12 12 12 12 12 12<br />

(2) FD Subfeed<br />

(Vertical Mtg.)<br />

N/A 24 24 24 N/A N/A N/A N/A N/A 24 24 24 24 N/A N/A N/A<br />

SPD 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12<br />

Split bus is paired with feed-thru lugs by default. Feed-thru lugs are to feed the section after the split.<br />

NOTE: N/A = OPTION NOT AVAILABLE<br />

*Min. Box Size, corresponding to 9" of Unit Space.<br />

Compression Lugs (Aluminum body except where not Al)<br />

Style<br />

MLO<br />

Main<br />

Breaker<br />

Amp<br />

Rating<br />

Breaker<br />

Type<br />

Compression<br />

Connectors<br />

Box Height<br />

Addition<br />

125 N/A (1)#6 - 350 kcmil Al/Cu 6<br />

250 N/A (1)#6 - 350 kcmil Al/Cu 6<br />

400 N/A<br />

(1) 400-600 Kcmil AL or<br />

(1) 400-500 Kcmil CU or<br />

6<br />

(2) #6 - 350 Kcmil Al/Cu<br />

600 N/A<br />

(2)#6 - 350 kcmil Cu or Cu/Al or<br />

400 - 600 kcmil Al/Cu<br />

6<br />

100<br />

ED4, ED6, HED4<br />

Box must go to 24" wide on CED6 breaker only<br />

HHED6, CED6 <br />

(1)#14-2/0 AWG Cu or Al<br />

Add 6" to box height for NØ<br />

225 QR2, QRH2, HQR2, HQR2H (1)#6 AWG - 350 kcmil Cu or Al Box must go to 24" wide<br />

250 FXD6, HFD6, CFD6 (1)#6 AWG - 350 kcmil Cu or Al<br />

Box must go to 24" wide for all breakers<br />

Requires an additional 6.0" box height<br />

JD6, JXD6, HJD6,<br />

400 CJD6, SJD6, SHJD6, (2)#1/0 AWG - 500 kcmil Cu or Al 9<br />

SCJD6<br />

LD6, LXD6, HLD6,<br />

600 CJD6, SLD6, SHLD6, (2)#2/0 AWG - 500 kcmil Cu or Al 6<br />

SCLD6<br />

Alternate Lugs<br />

Amp<br />

Style Rating<br />

Breaker<br />

Type<br />

MLO 400 N/A<br />

Main<br />

Breaker<br />

400<br />

JD6, JXD6, HJD6,<br />

CJD6, SJD6, SHJD6,<br />

SCJD6<br />

Standard AL<br />

Connectors<br />

(1) 250 - 750 kcmil or<br />

(2)#3/0 AWG - 250 kcmil Cu or Al<br />

(1)#4/0 AWG - 750 kcmil Cu or Al 6<br />

Box Height<br />

Addition<br />

6<br />

Not available for feed thru lug.<br />

11-36<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category PBSB


Panelboards<br />

Type P2 Panelboard Connector Modifications<br />

Revised on 04/30/19<br />

Selection<br />

Enclosure Modifications<br />

Description<br />

20" Panel Width<br />

NEMA 3R enclosures<br />

NEMA 3R/12 enclosures<br />

Gasket between trim and box (Type 1)<br />

24" Panel Width<br />

NEMA 3R enclosures<br />

NEMA 3R/12 enclosures <br />

Gasket between trim and box (Type 1)<br />

11 PANELBOARDS<br />

NEMA-4—Water Tight, Dust Tight,<br />

Steel Enclosure (Actual NEMA-4<br />

enclosure is larger than standard<br />

Type 1 enclosure. See chart below for<br />

reference to approximate actual size.)<br />

Standard<br />

Box Height<br />

(in inches)<br />

Actual NEMA 4<br />

Enclosure Size <br />

H W D<br />

32 32 20 8<br />

38 42 30 8<br />

44 48 36 8<br />

56 60 36 10<br />

NOTE: Larger NEMA 4 enclosures are<br />

not available.<br />

NEMA-4X—Water Tight, Dust Tight and Corrosion Resistant <br />

(consult plant for actual enclosure size)<br />

Catalog<br />

Number<br />

Enclosure – Stainless Steel<br />

Size (inches) (304SS is standard)<br />

Enclosure – Fiberglass<br />

Size (inches)<br />

H W D H D W<br />

B4X26 26 20 5.75 36 30 8<br />

B4X32 32 20 5.75 36 30 8<br />

B4X38 38 20 5.75 48 36 12<br />

B4X44 44 20 5.75 48 36 12<br />

B4X50 50 20 5.75 60 36 12<br />

B4X56 56 20 5.75 60 36 12<br />

B4X62 62 20 5.75<br />

B4X68 68 20 5.75<br />

B4X74 74 20 5.75<br />

NOTE: 316SS is available as an option - must be specified.<br />

a16 Gauge Cans w/ 14 Gauge Front)<br />

b 14 Gauge only<br />

c 14 Gauge only - 304SS Std, 316SS Optional)<br />

Gauge Steel of Boxes/Fronts, Surface and Flush (see pgs. 11-6 & 11-7)<br />

Dimensions in Inches (mm)<br />

Gauge Steel<br />

H W Box Front/Door Type<br />

26-74 (660-1880) 20 (508) 16 14 Type 1<br />

26-74 (660-1880) 20 (508) 16 16/14 Type 3R/12<br />

32-60 (813-1524) 20-36 (508-914) 14 14 Type 4<br />

26-74 (660-1879) 20 (508) 14 14 Type 4X<br />

36-60 (914-1524) 30-36 (762-914) N/A N/A Type 4X Non-Metallic<br />

16 Gauge is Standard (14 Gauge & 12 Gauge are optional)<br />

15 Gauge Steel Can with 14 Gauge Door or Similar Approved Construction<br />

No Optional Gauge available<br />

304SS 14 Gauge Std., 316SS 14 Gauge optional<br />

Sizes do not match Standard Enclosure Sizes - See Table P1-21 - material is non-metallic - No Gauge Specified.<br />

f FAS-Latch is 14 GA only.<br />

Screw-to-Box, Hinge-to-Box, Door-in-Door (14 GA Std./12 GA Std. or 10 GA Optional)<br />

STB/HTB/DND with Piano Hinge (14 GA Std./12 GA Optional) (14 GA Stainless 304 Optional)<br />

Product Category PBSB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-37


Panelboards<br />

Type P2 Panelboard Kits and Accessories<br />

Revised on 04/30/19<br />

Selection<br />

11<br />

PANELBOARDS<br />

Standard Enclosures<br />

Catalog Number<br />

Box<br />

Type 1 Standard Trim<br />

Height<br />

Inches Box Surface Flush Type 3R Type 3R/12 a<br />

26 B26 S26B F26B NR26 WP26<br />

32 B32 S32B F32B NR32 WP32<br />

38 B38 S38B F38B NR38 WP38<br />

44 B44 S44B F44B NR44 WP44<br />

50 B50 S50B F50B NR50 WP50<br />

56 B56 S56B F56B NR56 WP56<br />

62 B62 S62B F62B NR62 WP62<br />

68 B68 S68B F68B NR68 WP68<br />

74 B74 S74B F74B NR74 WP74<br />

Same as Type 3R with Gasket added for Type 12 Spec.<br />

Options For Type 1 Trims<br />

Items must be ordered as manual line item on Spartanburg<br />

n Hinged trim – Replace “B” suffix with “H”<br />

n Door-in-door – Replace “B” suffix with “D”<br />

n Screw to Box - Replace "B" suffix with "C"<br />

n Metal card holder - Add "M" suffix on all trims<br />

n Stainless Steel – 304 Stainless only with piano hinge<br />

Option For 24" Wide Enclosures with Equal Gutter on<br />

Both Sides (Excludes NEMA 3R)<br />

n 24" wide with equal gutter on both sides - Add “24” as prefix<br />

Breaker Kits and Accessories<br />

Kit Number Description Contents<br />

BBKB32 (P2/P3) BL/BQD 6-pole 3" branch breaker kit Kit contains top barrier, (3) A/C connectors, (1) B connector, hardware<br />

BBKED32 (P2/P3) ED 6-pole 3" branch breaker kit<br />

Kit contains breaker support, inter-phase barriers, (3) A/C connectors, (1)<br />

B connector, hardware<br />

BBKNB32 (P2/P3) xGB 6-pole 3" branch breaker kit Kit contains top barrier, (3) A/C connectors, (1) B connector, hardware<br />

BBKGB32 (P2/P3) xGB2 6-pole 3" branch breaker kit Kit contains top barrier, (3) A/C connectors, (1) B connector, hardware<br />

BBKQ1 (P2) QJ branch breaker kit for 2 and 3-pole single mount<br />

Kit to contain all connectors and cover plates necessary to mount both<br />

2 and 3-pole QJ breakers<br />

BBKQR1 (P2) a P2 branch BKR strap kit for single QR 1-phase/3-phase.<br />

Kit to contain all connectors and cover plates necessary to mount both<br />

2 and 3-pole breakers<br />

DFK1 (P2) BL, BQD, ED deadfront kit for 1" pole breakers Center strips 3", 6", 9", 12", 15", 18", 21" plus mounting hardware<br />

DFFP3 Deadfront filler 3" 3" empty space filler and hardware<br />

DFFP6 Deadfront filler 6" 6" empty space filler and hardware<br />

BNK2 Branch neutral (P2) Three tier lug with mounting hardware to increase neutral capacity<br />

P2BK1 P2 250A max. Bonding Kit Bonding strap and hardware<br />

P2BK2 P2 400A max. Bonding Kit Bonding strap and hardware<br />

P2BK3 P2 600A max. Bonding Kit Bonding strap and hardware<br />

BBKQRP1FK<br />

P2 Filler for QR. Horizontal or vertical mount. 1-phase/3- Kit contains all cover plates necessary to change from QJ to QR both<br />

phase.<br />

2 and 3-pole breakers.<br />

SEBKP2V1 c BL, BQD Main Service Entrance Barrier (P2 only) Kit contains barrier, mounting brackets, and hardware<br />

SEBKP2V2 c xGB Main Service Entrance Barrier (P2 only) Kit contains barrier, mounting brackets, and hardware<br />

SEBKP2V3 c FD, QJ, QR Horizontal Main Service Entrance Barrier<br />

(P2, P2 with SEM3, P3)<br />

Kit contains barrier, mounting brackets, and hardware<br />

SEBKP2V4 c<br />

FD, QJ, QR Vertical Main Service Entrance Barrier<br />

(P2, P2 with SEM3)<br />

Kit contains barrier, mounting brackets, and hardware<br />

SEBKP2V5 c<br />

ED Horizontal Main Service Entrance Barrier<br />

(P2, P2 with SEM3)<br />

Kit contains barrier, mounting brackets, and hardware<br />

SEBKP2V6 c<br />

ED Vertical Main Service Entrance Barrier<br />

(P2, P2 with SEM3)<br />

Kit contains barrier, mounting brackets, and hardware<br />

SEBKP1P2P3V1 c JD, LD Service Entrance Barrier Kit (RP1, P1, P2, P3) Kit contains barrier, mounting brackets, and hardware<br />

Although QR is rated 250A, it is limited to 225A in panelboard.<br />

Two kits required for P2 Extended circuit Panels<br />

c Factory installed and Field installable Service Entrance Barrier kits are now available as required by UL67. (In COMPAS, you must select Service Entrance Required.)<br />

Type P1, P2, and P3 Panelboards<br />

Miscellaneous Parts and Accessories<br />

Catalog No. Description<br />

Catalog No. Description<br />

EGK<br />

Al Ground Bus 44 Connections<br />

NBK6 Number Strips 86-168 (snap-in type, P2/P3 panels)<br />

P2BK1 P2 250A Max Horiz. Main Breaker<br />

NBK7 Number Strips 169-210 (snap-in type, P2/P3 panels)<br />

P2BK2 P2 125A Main Lug Bonding Kit<br />

NBK8 Number Strips 211-252 (snap-in type, P2/P3 panels)<br />

P2BK3 P2 250-600A Main Lug and all Vert. Main Breaker Bonding Kit ECGK Cu Ground Bus 44 Connections<br />

IMK1<br />

Interior Adjusting Kit<br />

IGK<br />

Insulated Al Ground Bus<br />

LPDC01 Directory Card (Pack of 10; ref. 12-1110-01)<br />

ICGK Insulated Cu Ground Bus<br />

LPDC02 Directory Card Holder (Pack of 10; ref. 11-1824-01)<br />

EWK1 End Wall Kit with Knockouts (20" W x 5.75" DP)<br />

ANSI/NEMA<br />

PB 1.1-2013<br />

General Instructions for Proper Installation, Operation, and<br />

Maintenance of Panelboards Rated 600 V or Less (O&M Manual) a<br />

EWK2<br />

DFFP1<br />

End Wall Kit with Knockouts (24" W x 7.75" DP)<br />

1" Filler Plate – (used for BL/BQD/xGB/xGB2/ED blank<br />

NBK3 Number Strips 1-42 (snap-in type, P2/P3 panels)<br />

positions) (suitable for replacing QF3 in P1 thru P5<br />

NBK4 Number Strips 43-84 (snap-in type, P2/P3 panels)<br />

Panelboards and Switchboards)<br />

NBK5 Number Strips 85-126 (snap-in type, P2/P3 panels)<br />

EBF1 NEB/HEB Filler Plate<br />

PDF can be downloaded (at no cost) and printed at this location: http://www.nema.org/standards/pages/Panelboards.aspx<br />

11-38<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category PBSB


Panelboards<br />

Type P2 Panelboards<br />

Revised on 04/30/19<br />

Dimensions<br />

Type 1 Box<br />

Box is symmetrical<br />

0.313 in. Dia.<br />

11 PANELBOARDS<br />

0.313 in. Dia.<br />

³⁄₄ in.<br />

[19 ]<br />

20 in.<br />

[ 508 ]<br />

³⁄₄ in.<br />

[19 ]<br />

(Mounting Holes<br />

0.437 in. Square)<br />

(UL approved construction. 16 Gage Steel or equivalent alternate Construction.<br />

14 or 12 Gage is available as an optional special order.)<br />

A60 Galvannealed is standard without paint.<br />

Type 3R and 3R/12 Box<br />

(Mounting Holes<br />

0.437 in. Square)<br />

8.0 in.<br />

[ 204 ]<br />

Flush Mounting<br />

8.0 in.<br />

[ 204 ]<br />

5.75 in.<br />

[ 146 ]<br />

(Mounting Holes<br />

0.437 in. Square)<br />

(Mounting Holes<br />

0.437 in. Square)<br />

(Mounting Holes<br />

0.437 in. Square)<br />

(Mounting Holes<br />

0.437 in. Square)<br />

(Mounting Holes<br />

0.437 in. Square)<br />

(Mounting Holes<br />

0.437 in. Square)<br />

23.0 in.<br />

[ 584 ]<br />

23.0 in.<br />

[ 584 ]<br />

(UL approved construction. 16 Gage Steel Can with<br />

14 Gage front or similar approved construction.)<br />

A60 Galvannealed with ANSI 61 light gray paint is standard.<br />

Dimensions are interior of the box. Add 5/8” to width for absolute<br />

dimension. Add 1/8” to height for absolute dimension.<br />

Dimensions shown in inches and millimeters [ ].<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-39


Panelboards<br />

Type P3 Panelboards<br />

Revised on 04/30/19<br />

General<br />

11<br />

PANELBOARDS<br />

Features<br />

Another innovation from Siemens is<br />

the P3 panel. It is a smaller, footprint<br />

distribution panel to fit a large number<br />

of applications that require more (or<br />

larger) branch devices than the lighting<br />

panel class offer. This panel offers a<br />

wide array of factory-assembled<br />

options, and has the ability to mix<br />

breaker frames in unit space up to<br />

250 amps. Bussing options for the P3<br />

vary from the standard temperature<br />

aluminum to temperature rated copper,<br />

750 A/Si aluminum, and 1000A/Si<br />

copper designs. All bussing in the P3<br />

panel is tin-plated as a standard.<br />

Silver-plated copper is offered as an<br />

option on a copper bus. Integrated<br />

time clocks, bus mounted contactors,<br />

as mains or sub mains, split bus and<br />

subfeed lugs (up to 400 amp) are just a<br />

few of the options of this unique panel.<br />

The P3 panel configurations, defined by<br />

the unit space, allow for a given<br />

amperage, main device, and box height.<br />

The P3 panel starts with a 56" high box.<br />

Breaker unit space can be mixed and<br />

matched to meet customer<br />

requirements. All 1" pole breakers<br />

(BL, BQD, xGB, xGB2, ED frames) are<br />

mounted in 3" or 6" pole increments.<br />

Breakers frames, above 125 amps, are<br />

mounted in 6" single or twin breaker<br />

mountings. QR (225A max) and 3VA52<br />

(250A max) breakers are twin mounted<br />

in 6" unit space. A max of 6 total large<br />

frame breakers are allowed in unit<br />

space. Any subfeed breakers do not<br />

reduce this. For example, FD 250 amp<br />

and JD 400 amp breakers are mounted<br />

as subfeed breakers outside of unit<br />

space.<br />

Main Lug/Main Breaker<br />

Enclosure – Standard Type 1 enclosure<br />

is 24" wide x 7.75" deep. X Box Height<br />

is determined by main device and unit<br />

space. See charts for box height.<br />

Voltage – 600V AC max.<br />

250V DC max.<br />

Amperage – 800 amp max.<br />

Short Circuit Rating – 200 Kaic max.<br />

symmetrical or equal to the lowest<br />

rated device installed unless a series<br />

rating is indicated. Panels with subfeed<br />

or feed-thru lugs without a main device,<br />

circuit breaker or fusible unit, are limited<br />

to a three-cycle rating. The three-cycle<br />

rating for the P3 panel is limited to 22<br />

Kaic. Note that the main device may be<br />

mounted remote from the panel.<br />

Bussing – The P3 panel has more<br />

options to meet market requirements.<br />

The standard bussing is temperature<br />

rated aluminum. The rating is per the<br />

requirements of UL 67 – the standard<br />

for panelboards. All aluminum bussing<br />

is tin-plated. Optional bussing for the P3<br />

panel is: 750 A/si aluminum,<br />

temperature rated copper, and 1000<br />

A/si copper. The copper bus option<br />

for this panel is tin-plated.<br />

Weight – Approximate<br />

Total panelboard weight when filled<br />

with a normal quantity of breakers and<br />

accessories is about 5 lbs. (1 kg) per<br />

inch (54g per mm) of box height.<br />

Gauge Steel of Boxes Fronts,<br />

Surface & Flush<br />

Dimensions in inches (mm) Gauge Steel<br />

Width Height Box Front<br />

24" 56 - 80" #16 #14<br />

(610) (1422, 2032)<br />

Like other distribution panels, the P3<br />

panel can have blank space added<br />

into the panel to allow for future<br />

expansions or modifications. Any<br />

expansions or modifications must<br />

be in 3" increments. BL, BQD, xGB,<br />

xGB2, and ED frame breakers have 3"<br />

or 6-pole kits and can be mixed in unit<br />

space by these increments. Breakers<br />

of the same frame can cross from one<br />

mounting to another if contiguous. xGB<br />

frame breakers cannot be mixed with<br />

other frame types. Any expansion or<br />

modification must be in 3" increments<br />

also. QR frame breakers are mounted<br />

in 6" increments for two and three<br />

pole single and twin mounted units.<br />

Changes in the unit space length for<br />

BL, BQD, xGB, xGB2, or ED frame<br />

breakers require an additional deadfront<br />

center strip kit. Check with sales or the<br />

factory for additional unit space kits.<br />

11-40<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Panelboards<br />

Type P3 Panelboards<br />

Revised on 04/30/19<br />

Selection/Dimensions<br />

Panel Unit Space To Box Height Requirements<br />

P3 Panels With Standard Line Lugs. Unit Space (starting with 9" and adding 6" increments) “A” Dimension<br />

Main Lugs<br />

Main Breakers<br />

“B” 250A 250A 250A 400A 400A 600A 600A<br />

Dimension Horiz. Vert. Vert. Vert. Vert. Vert. Vert.<br />

Box Height 250A 400A 600A 800A FD FD CFD JD CJD LD CLD<br />

56 27 21 21 21 21 15 9 9 — 9 —<br />

62 33 27 27 27 27 21 15 15 9 15 9<br />

68 39 33 33 33 33 27 21 21 15 21 15<br />

74 45 39 39 39 39 33 27 27 21 27 21<br />

80 45 45 45 45 45 39 33 33 27 33 27<br />

11 PANELBOARDS<br />

Main Breaker Wire Bending<br />

Breaker<br />

Frame C E F<br />

FD Horiz. 7.25 — 20.13<br />

FD Vert. — 12.25 25.38<br />

CFD — 13.63 31.38<br />

JD — 15.63 29.38<br />

CJD — 14.75 35.38<br />

LD — 14.75 29.38<br />

CLD — 14.00 35.38<br />

Main Lug Wire Bending<br />

Panel Amps Standard Connectors C D<br />

250 (1) #6 AWG - 350 kcmil 10.75 1 13.50<br />

400 (2) #3/0 AWG - 250 kcmil 16.00 17.88<br />

or (1) 600 kcmil<br />

600 (2) #3/0 AWG - 500 kcmil 16.00 17.88<br />

800 b (2) 600 kcmil 16.00 17.88<br />

aThis lug is removable.<br />

bCU wire Required for 800A with 2 cables. See Alternate<br />

Lugs page 11-47 for 3 cables CU or AL options.<br />

Main Breaker Wire Bending Diagram<br />

Main Lug Wire Bending Diagram<br />

Box depth = 7.75 in. (197 mm)<br />

Box width = 24 in. (610 mm)<br />

Main Breaker Wire Bending<br />

Branch Breaker<br />

Side Gutters Inches (mm)<br />

Reference<br />

Panel<br />

Letter Width 24" (609)<br />

A 7.750 (197)<br />

B 7.125 (181)<br />

C 6.000 (152)<br />

D 1 7.000 (178)<br />

E 5.000 (127)<br />

F 6.625 (168)<br />

G 5.500 (140)<br />

a Single branch mounting construction.<br />

b BQD6 is not UL Listed. Only for CUL and CSA panels.<br />

Box depth = 7.75 in. (197 mm)<br />

Box width = 24 in. (610 mm)<br />

Main Lug Wire Bending<br />

Branch Breaker Wire Bending Diagram<br />

A<br />

BL, BLH, HBL<br />

BL, BLH, HBL<br />

BLF2, BLHF2<br />

BLF2, BLHF2<br />

A<br />

B HBLF2, BLFB, BLHFB HBLF2, BLFB, BLHFB B<br />

BQD, BQD6 b<br />

BQD, BQD6 b<br />

C<br />

D/E<br />

F<br />

ED4, ED6<br />

QR2, QRH2<br />

NGB, HGB, LGB<br />

ED4, ED6<br />

QR2, QRH2<br />

NGB, HGB, LGB<br />

HED4, HHED6<br />

HQR2, HQR2H<br />

NGB2, HGB2, LGB2<br />

HED4, HHED6<br />

HQR2, HQR2H<br />

NGB2, HGB2, LGB2<br />

C<br />

D/E<br />

F<br />

G<br />

MFAS, HFAS, CFAS MFAS, HFAS, CFAS<br />

(3VA52)<br />

(3VA52)<br />

G<br />

Panel Width<br />

24 in. (610 mm)<br />

Branch Breaker Side Gutters<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-41


Panelboards<br />

Type P3 Panelboards<br />

Revised on 04/30/19<br />

Selection<br />

11<br />

PANELBOARDS<br />

Alternate Main Breakers<br />

Ampere<br />

Rating<br />

250<br />

400<br />

600<br />

Max. Interrupting Rating (kA) Ref.<br />

Breaker<br />

Type Horizontal<br />

Available Configurations <br />

Type 240V 480V 600V Code or Vertical 240V AC 480V AC 600V AC Available Trip Values<br />

FD6 65 35 18 FD H/V STD STD STD 70, 80, 90, 100, 110, 125, 150, 200, 225, 250<br />

FXD6 65 35 18 FX H/V STD STD STD 70, 80, 90, 100, 110, 125, 150, 200, 225, 250<br />

HFD6 100 65 25 HF H/V ADD ADD ADD 70, 80, 90, 100, 110, 125, 150, 200, 225, 250<br />

HFXD6 100 65 25 H2 H/V ADD ADD ADD 70, 80, 90, 100, 110, 125, 150, 200, 225, 250<br />

CFD6 a 200 150 100 CF V ADD ADD ADD 70, 80, 90, 100, 110, 125, 150, 200, 225, 250<br />

JXD6 a 65 35 25 JX V STD STD STD 200, 225, 250, 300, 350, 400<br />

JD6 a 65 35 25 J6 V STD STD STD 200, 225, 250, 300, 350, 400<br />

HJXD6 a 100 65 35 H6 V ADD ADD ADD 200, 225, 250, 300, 350, 400<br />

HJD6 a 100 65 35 H5 V ADD ADD ADD 200, 225, 250, 300, 350, 400<br />

SJD6 a 65 35 25 SJ V ADD ADD ADD 200, 300, 400<br />

SHJD6 a 100 65 35 S2 V ADD ADD ADD 200, 300, 400<br />

CJD6 a 200 200 100 CJ V ADD ADD ADD 200, 300, 400<br />

SCJD6 a 200 200 100 SC V ADD ADD ADD 200, 300, 400<br />

LXD6 a 65 35 25 LX V STD STD STD 450, 500, 600<br />

LD6 a 65 35 25 L6 V STD STD STD 250, 300, 350, 400, 450, 500, 600<br />

HLXD6 a 100 65 35 HL V ADD ADD ADD 250, 300, 350, 400, 450, 500, 600<br />

HLD6 a 100 65 35 HO V ADD ADD ADD 250, 300, 350, 400, 450, 500, 600<br />

SLD6 a 65 35 25 SL V ADD ADD ADD 300, 400, 500, 600<br />

SHLD6 a 100 65 35 S6 V ADD ADD ADD 300, 400, 500, 600<br />

CLD6 a 200 150 100 CL V ADD ADD ADD 300, 400, 500, 600<br />

SCLD6 200 150 100 C6 V ADD ADD ADD 300, 400, 500, 600<br />

a Vertically mounted<br />

STD = Standard configuration. ADD = Additional cost.<br />

11-42<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category PBSB


Panelboards<br />

Type P3 Panelboards<br />

Revised on 04/30/19<br />

Selection<br />

P3 Branch Circuit Breakers<br />

Amp<br />

Rating<br />

100<br />

xx<br />

125<br />

225<br />

250<br />

Trip<br />

Type<br />

Thermal<br />

Magnetic<br />

Breaker<br />

Family<br />

BL<br />

Special BLG<br />

Application BL<br />

Thermal<br />

Magnetic<br />

BQD<br />

Electronic<br />

and misc.<br />

Thermal<br />

Magnetic<br />

Thermal<br />

Magnetic<br />

Thermal<br />

Magnetic<br />

BL<br />

GB<br />

Sentron<br />

GB2<br />

3VA41 c<br />

QR<br />

3VA52 d<br />

(W/TM230<br />

trip)<br />

Breaker<br />

Type<br />

1-Pole<br />

Max IR (kA) at<br />

120V 277V 347V<br />

125V<br />

DC<br />

Amp<br />

Ratings<br />

Avail.<br />

2-Pole and 3-Pole<br />

Max IR (kA) at<br />

120/<br />

240V<br />

240V<br />

480Y/<br />

277V<br />

480V<br />

600Y/<br />

347V<br />

600V<br />

125/<br />

250V<br />

DC<br />

250V<br />

DC<br />

Amp<br />

Ratings<br />

Avail.<br />

S = Single Mount<br />

T = Twin mount<br />

S<br />

T<br />

Unit Max<br />

Space 1-pole<br />

per Kit Circuits<br />

(in.) per Kit<br />

BL 10 — — — 15-70 10 10 — — — — — — 15-100 d — T 3.00 6<br />

BLH 22 — — — 15-70 22 22 — — — — — — 15-100 d — T 3.00 6<br />

HBL 65 — — — 15-50 65 65 — — — — — — 15-100 — T 3.00 6<br />

BLG a 10 — — — 15-20 10 — — — — — — — 30 — T 3.00 6<br />

BL (HID) 10 — — — 15-30 10 — — — — — — — 15-30 — T 3.00 6<br />

BQD f 65 14 — 14 15-100 — 65 14 — — — 14 — 15-100 — T 3.00 6<br />

BQD6 g 65 — — 14 15-70 — 65 — 10 — 14 — 15-70 — T 3.00 6<br />

AFCI/<br />

GFCI<br />

& Dual<br />

Function<br />

x — — —<br />

see<br />

special<br />

table<br />

page<br />

11-13<br />

x — — — — — — —<br />

see<br />

special<br />

table<br />

page<br />

11-13<br />

— T 3.00 6<br />

NGB 100 25 14 14 15-125 — 100 25 — 14 — 14 — 15-125 — T 3.00 6<br />

HGB 100 35 14 14 15-125 — 100 35 — 14 — 14 — 15-125 — T 3.00 6<br />

LGB 100 65 14 14 15-125 — 100 65 — 14 — 14 — 15-125 — T 3.00 6<br />

ED4 — 22 — 30 15-100 — 65 — 18 — — — 30 15-125 — T 3.00 6<br />

ED6 — — — — — — 65 — 25 — 18 — 30 20-125 — T 3.00 6<br />

HED4 b — — — — — — 65 — 18 b — — — 30 15-125 — T 3.00 6<br />

HHED6 — — — — — — 100 — 65 — 18 — — 15-50 — T 3.00 6<br />

NGB2 100 25 14 14 d 15-125 — 100 — 25 14 — 14 e — 15-125 — T 3.00 6<br />

HGB2 100 35 22 14 d 15-125 — 100 — 35 22 — 14 e — 15-125 — T 3.00 6<br />

LGB2 100 65 25 14 d 15-125 — 100 — 65 25 — 14 e — 15-125 — T 3.00 6<br />

info not x x x x x x x — x — — x — T 3.00 6<br />

yet available<br />

x x x x x x x — x — — x — T 3.00 6<br />

x x x x x x x — x — — x — T 3.00 6<br />

QR2 — — — — — — 10 — — — — — — 100-225 — T 6.00 6<br />

QRH2 — — — — — — 25 — — — — — — 100-225 — T 6.00 6<br />

HQR2 — — — — — — 65 — — — — — — 100-225 — T 6.00 6<br />

HQR2H — — — — — — 100 — — — — — — 100-225 — T 6.00 6<br />

MFAS — — — — — 85 85 — 35 — 18 — — 100-250 — T 6.00 6<br />

HFAS — — — — — 100 100 — 65 — 25 — — 100-250 — T 6.00 6<br />

CFAS — — — — — 200 200 — 100 — 35 — — 100-250 — T 6.00 6<br />

11 PANELBOARDS<br />

Subfeed Breakers (available in 2-pole or 3-pole)<br />

Breaker<br />

Type<br />

Mounting Position When<br />

Used as Subfeed Breaker<br />

Ampere<br />

Ratings<br />

For Load<br />

Maximum Interrupting Rating<br />

(kA) Symmetrical<br />

240V AC 480V AC 600V AC<br />

FD6 h , FXD6 Twin (Vertical) 70–250 65 35 18<br />

HFD6 h , HFXD6 Twin (Vertical) 70–250 100 65 25<br />

JD6 i , JXD6 Single (Horizontal) 200–400 65 35 25<br />

HJD6 i , HJXD6 Single (Horizontal) 200–400 100 65 35<br />

Neutral Connectors<br />

Wire Range<br />

Max.<br />

Number of Max.<br />

Connections Amps<br />

#14-#1/0 44 125<br />

#4 - 350 kcmil 6 250<br />

(1)#4 - 600 kcmil or<br />

(2)#6 - 250 kcmil<br />

1 400<br />

a BLG two-pole breaker is one phase and neutral. Three<br />

pole is two phases and neutral - See SpeedFax page 7-31<br />

b 1-pole HED 15-30A rated 65kA; 35-100A rated 25kA:<br />

3-pole HED rated 42kA<br />

c Availability and additional specs tbd, expected late 2019.<br />

(COMPAS may allow selection of alternate trip units)<br />

d Twin Mount 3VA52 available 2018 with Thermal<br />

Magnetic Trip (TMTU), 3VA62 with Electronic Trip<br />

(ETU) availability tbd.<br />

e 2-pole only or two outer poles of 3-pole breaker<br />

f Approved for CSA and UL Listed.<br />

g Approved for CSA but not UL Listed.<br />

h Twin mounted subfeed breakers are mounted at bottom<br />

of panelboard only and adds 24" to the panel height.<br />

i Subfeed breaker is mounted at bottom of panelboard<br />

only. 400 amp subfeed breaker adds 30" to the panel<br />

height.<br />

Product Category PBSB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-43


Panelboards<br />

Type P3 Panelboards<br />

Revised on 05/01/17<br />

Selection<br />

11<br />

PANELBOARDS<br />

Typical Catalog Numbers<br />

Main Lugs Only – Examples of Panel numbers w/o options that add to box height.<br />

– Shown with Aluminum bus, Top fed, and Surface Trims<br />

Max. Panel<br />

Amp Rating<br />

250<br />

400<br />

600<br />

800<br />

Max.Unit<br />

Space<br />

(inches)<br />

120/240V<br />

1-Phase, 3-Wire<br />

208Y/120V<br />

3-Phase, 4-Wire<br />

240/120V Delta 3Ø4W<br />

BØ High Leg<br />

Catalog Number Catalog Number Catalog Number<br />

Box<br />

Height<br />

Inches<br />

27 P3A56ML250ATS P3C56ML250ATS P3B56ML250ATS 56<br />

33 P3A62ML250ATS P3C62ML250ATS P3B62ML250ATS 62<br />

39 P3A68ML250ATS P3C68ML250ATS P3B68ML250ATS 68<br />

45 P3A74ML250ATS P3C74ML250ATS P3B74ML250ATS 74<br />

45 P3A80ML250ATS P3C80ML250ATS P3B80ML250ATS 80<br />

21 P3A56ML400ATS P3C56ML400ATS P3B56ML400ATS 56<br />

27 P3A62ML400ATS P3C62ML400ATS P3B62ML400ATS 62<br />

33 P3A68ML400ATS P3C68ML400ATS P3B68ML400ATS 68<br />

39 P3A74ML400ATS P3C74ML400ATS P3B74ML400ATS 74<br />

45 P3A80ML400ATS P3C80ML400ATS P3B80ML400ATS 80<br />

21 P3A56ML600ATS P3C56ML600ATS P3B56ML600ATS 56<br />

27 P3A62ML600ATS P3C62ML600ATS P3B62ML600ATS 62<br />

33 P3A68ML600ATS P3C68ML600ATS P3B68ML600ATS 68<br />

39 P3A74ML600ATS P3C74ML600ATS P3B74ML600ATS 74<br />

45 P3A80ML600ATS P3C80ML600ATS P3B80ML600ATS 80<br />

21 P3A56ML800ATS P3C56ML800ATS P3B56ML800ATS 56<br />

27 P3A62ML800ATS P3C62ML800ATS P3B62ML800ATS 62<br />

33 P3A68ML800ATS P3C68ML800ATS P3B68ML800ATS 68<br />

39 P3A74ML800ATS P3C74ML800ATS P3B74ML800ATS 74<br />

45 P3A80ML800ATS P3C80ML800ATS P3B80ML800ATS 80<br />

Max. Panel<br />

Amp Rating<br />

Max.Unit<br />

Space<br />

(inches)<br />

480V Delta<br />

3-Phase, 3-Wire<br />

240V Delta<br />

3-Phase, 3-Wire<br />

480Y/277V<br />

3-Phase, 4-Wire<br />

Catalog Number Catalog Number Catalog Number<br />

Box<br />

Height<br />

Inches<br />

27 P3F56ML250ATS P3D56ML250ATS P3E56ML250ATS 56<br />

33 P3F62ML250ATS P3D62ML250ATS P3E62ML250ATS 62<br />

250<br />

39 P3F68ML250ATS P3D68ML250ATS P3E68ML250ATS 68<br />

45 P3F74ML250ATS P3D74ML250ATS P3E74ML250ATS 74<br />

45 P3F80ML250ATS P3D80ML250ATS P3E80ML250ATS 80<br />

21 P3F56ML400ATS P3D56ML400ATS P3E56ML400ATS 56<br />

27 P3F62ML400ATS P3D62ML400ATS P3E62ML400ATS 62<br />

400<br />

33 P3F68ML400ATS P3D68ML400ATS P3E68ML400ATS 68<br />

39 P3F74ML400ATS P3D74ML400ATS P3E74ML400ATS 74<br />

45 P3F80ML400ATS P3D80ML400ATS P3E80ML400ATS 80<br />

21 P3F56ML600ATS P3D56ML600ATS P3E56ML600ATS 56<br />

27 P3F62ML600ATS P3D62ML600ATS P3E62ML600ATS 62<br />

600<br />

33 P3F68ML600ATS P3D68ML600ATS P3E68ML600ATS 68<br />

39 P3F74ML600ATS P3D74ML600ATS P3E74ML600ATS 74<br />

45 P3F80ML600ATS P3D80ML600ATS P3E80ML600ATS 80<br />

21 P3F56ML800ATS P3D56ML800ATS P3E56ML800ATS 56<br />

27 P3F62ML800ATS P3D62ML800ATS P3E62ML800ATS 62<br />

800<br />

33 P3F68ML800ATS P3D68ML800ATS P3E68ML800ATS 68<br />

39 P3F74ML800ATS P3D74ML800ATS P3E74ML800ATS 74<br />

45 P3F80ML800ATS P3D80ML800ATS P3E80ML800ATS 80<br />

General Note: Panel numbers and box sizes are for reference only - COMPAS will configure proper Box size needed.<br />

11-44<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category PBSB


Panelboards<br />

Type P3 Panelboards<br />

Revised on 05/01/17<br />

Selection<br />

Typical Catalog Numbers<br />

Main Circuit Breaker – Examples of Panel numbers w/o options that add to box height.<br />

– Shown with Aluminum bus, Top fed, and Surface Trims<br />

Max. Panel<br />

Amp Rating<br />

Max.Unit<br />

Space<br />

(inches)<br />

120/240V<br />

1-Phase, 3-Wire<br />

208Y/120V<br />

3-Phase, 4-Wire<br />

240/120V Delta 3Ø4W<br />

BØ High Leg<br />

Catalog Number Catalog Number Catalog Number<br />

250 a 33 P3A68FD250ATS P3B68FD250ATS P3C68FD250ATS 68<br />

21 P3A56FD250ATS P3B56FD250ATS P3C56FD250ATS 56<br />

27 P3A62FD250ATS P3B62FD250ATS P3C62FD250ATS 62<br />

39 P3A74FD250ATS P3B74FD250ATS P3C74FD250ATS 74<br />

45 P3A80FD250ATS P3B80FD250ATS P3C80FD250ATS 80<br />

400 b 21 P3A68JD400ATS P3B68JD400ATS P3C68JD400ATS 68<br />

9 P3A56JD400ATS P3B56JD400ATS P3C56JD400ATS 56<br />

15 P3A62JD400ATS P3B62JD400ATS P3C62JD400ATS 62<br />

27 P3A74JD400ATS P3B74JD400ATS P3C74JD400ATS 74<br />

33 P3A80JD400ATS P3B80JD400ATS P3C80JD400ATS 80<br />

600 c 21 P3A68LD600ATS P3B68LD600ATS P3C68LD600ATS 68<br />

9 P3A56LD600ATS P3B56LD600ATS P3C56LD600ATS 56<br />

15 P3A62LD600ATS P3B62LD600ATS P3C62LD600ATS 62<br />

27 P3A74LD600ATS P3B74LD600ATS P3C74LD600ATS 74<br />

33 P3A80LD600ATS P3B80LD600ATS P3C80LD600ATS 80<br />

Box<br />

Height<br />

Inches<br />

11 PANELBOARDS<br />

Max. Panel<br />

Amp Rating<br />

Max.Unit<br />

Space<br />

(inches)<br />

480V Delta<br />

3-Phase, 3-Wire<br />

240V Delta<br />

3-Phase, 3-Wire<br />

480Y/277V<br />

3-Phase, 4-Wire<br />

Catalog Number Catalog Number Catalog Number<br />

250 a 33 P3F68FD250ATS P3D68FD250ATS P3E68FD250ATS 68<br />

21 P3F56FD250ATS P3D56FD250ATS P3E56FD250ATS 56<br />

27 P3F62FD250ATS P3D62FD250ATS P3E62FD250ATS 62<br />

39 P3F74FD250ATS P3D74FD250ATS P3E74FD250ATS 74<br />

45 P3F80FD250ATS P3D80FD250ATS P3E80FD250ATS 80<br />

400 b 21 P3F68JD400ATS P3D68JD400ATS P3E68JD400ATS 68<br />

9 P3F56JD400ATS P3D56JD400ATS P3E56JD400ATS 56<br />

15 P3F62JD400ATS P3D62JD400ATS P3E62JD400ATS 62<br />

27 P3F74JD400ATS P3D74JD400ATS P3E74JD400ATS 74<br />

33 P3F80JD400ATS P3D80JD400ATS P3E80JD400ATS 80<br />

600 c 21 P3F68LD600ATS P3D68LD600ATS P3E68LD600ATS 68<br />

9 P3F56LD600ATS P3D56LD600ATS P3E56LD600ATS 56<br />

15 P3F62LD600ATS P3D62LD600ATS P3E62LD600ATS 62<br />

27 P3F74LD600ATS P3D74LD600ATS P3E74LD600ATS 74<br />

33 P3F80LD600ATS P3D80LD600ATS P3E80LD600ATS 80<br />

General Note: Panel numbers and box sizes are for reference only - COMPAS will configure proper Box size needed.<br />

Box<br />

Height<br />

Inches<br />

a 250A: for Vert. FD subtract 6" of unit space; for CFD<br />

subtract 12" of unit space<br />

b 400A: for CJD box height 56 does not exist, subtract 6"<br />

from unit space for all others<br />

c 600A: for CLD box height 56 does not exist, subtract 6"<br />

from unit space for all others<br />

Product Category PBSB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-45


Panelboards<br />

Type P3 Panelboard Modifications and Additions<br />

Revised on 04/30/19<br />

Selection<br />

11<br />

PANELBOARDS<br />

Enclosures<br />

Extra Gutter to Sides or Ends<br />

of the Can (Type 1 Only)<br />

Description<br />

6" end gutter<br />

2" side gutter<br />

Barrier in gutter (add to extra<br />

gutter price – min 4" required)<br />

Hinged trims<br />

Piano hinged trims<br />

Door-in-door trims<br />

Screw to the box trims<br />

Trim mounted devices . . . . . See page 11-104<br />

• Pilot lights<br />

• Toggle switches<br />

• Push buttons<br />

Painted boxes . . . . . . . . . . . . See page 11-104<br />

Custom colors . . . . . . . . . . See painted boxes<br />

Increase gauge trims<br />

and boxes . . . . . . . . . . . . . . See page 11-104<br />

Stainless steel trims,<br />

Type 1 . . . . . . . . . . . . . . . . . See page 11-104<br />

Meters<br />

(Contact sales for pricing and application<br />

engineering for space requirements)<br />

Panel Skirts See page 11-105<br />

Special Locks (see page 11-7)<br />

TEY<br />

TEU1<br />

Cat 60<br />

LL803<br />

LL806<br />

Yale 47 (NYC)<br />

National C413A<br />

Best Lock 7-pin tumbler<br />

Southco 1/4" Fastener<br />

Corbin 1001 FAB7<br />

Panel Bus Modifications<br />

Catalog Number Addition<br />

Amperes Ratings<br />

Main Bus<br />

125A 250A 400A 600A<br />

750 A/SI AL. B B B B<br />

Copper (tin pltd.) F F F F<br />

Copper (silver E E E E<br />

pltd.)<br />

1000 A/SI Copper G G G G<br />

(tin pltd.)<br />

1000 A/SI Copper<br />

(silver pltd.)<br />

H H H H<br />

Subfeed, Feed-Thru and Split<br />

Bus (for 2-pole or 3-pole)<br />

Ampere<br />

Rating<br />

Branch and Main Breaker Accessories<br />

See page 11-102 and Breaker Section<br />

• Handle blocks<br />

• Handle locks<br />

• Aux. Contacts a<br />

• UVR a<br />

Increase capacity neutral up to 200%<br />

Main Bus Amps<br />

125<br />

250<br />

400<br />

600<br />

See page 11-47 for unit space adders and<br />

compatibility with other options.<br />

Copper MLO Only<br />

Main Bus Amps<br />

125<br />

250<br />

400<br />

600<br />

Connector<br />

Cu/Al Wire Range<br />

Unit<br />

Space<br />

(inches)<br />

Subfeed (Double) Lugs for Main Lug<br />

Panelboards Only (400 max)<br />

225/250 (2)—#6 AWG-350 kcmil 6<br />

400<br />

(4)—250 kcmil<br />

(2)—600 kcmil<br />

6<br />

Feed-Thru Lugs — Cannot Be Used<br />

in Conjunction with TVSS or Subfeed<br />

Breakers<br />

See page 11-47 for unit space adders and<br />

compatibility with other options.<br />

225/250 (1)—#6 AWG-350 kcmil 6<br />

400<br />

(2)—250 kcmil<br />

(1)—600 kcmil<br />

6<br />

600 (2)—250-500 kcmil 9<br />

800 (2)—600 kcmil 12<br />

Split Bus (1 per interior)<br />

225/250 (1)—#6 AWG-350 kcmil 6<br />

400 (2)—250 kcmil<br />

6<br />

(1)—600 kcmil<br />

600 (2)—250-500 kcmil 6<br />

800 (2)—600 kcmil 6<br />

(Devices mounted and wired to the trim should<br />

also have hinge-to-box trim specified)<br />

Bus mounted SPD<br />

See Section 10 for TPS1<br />

Service Entrance Label<br />

Type P3 Panelboards are factory labeled<br />

suitable for use as service entrance<br />

equipment when NEC requirements are met.<br />

A panelboard cannot have more than six<br />

main disconnects, unless it is a lighting and<br />

appliance branch panelboard. Lighting and<br />

appliance branch panelboards are limited to<br />

two main disconnects. Factory installed and<br />

Field installable Service Entrance Barrier kits<br />

are now available as required by UL67 (In<br />

COMPAS, you must select Service Entrance<br />

Required).<br />

Grounding of Panelboards<br />

Ground Bars except for brazed to box are<br />

shipped with the panel interior not factory<br />

mounted.<br />

• Non-Insulated Equipment Ground Bar<br />

• Copper Non-Insulated Ground Bar<br />

• Al Insulated Equipment Ground Bar<br />

• Cu Insulated Equipment Ground Bar<br />

• Ground Bar Brazed to Box<br />

(Not recommended for painted or<br />

NEMA 3R enclosures)<br />

Shunt Trip on Main or Branch<br />

BL, BLH, HBL, BQD, ED4, HED4, ED6,<br />

HHED6, QR2, QRH2, HQR2, HQR2H as<br />

branch only. BL, BLH, HBL, NGB, HGB,<br />

LGB, ED4, HED4, ED6, HHED6 uses 1"<br />

unit space for shunt trip. All others may<br />

be used on mains or subfeeds.<br />

Time Clocks<br />

Time clocks may be mounted in a 23"<br />

enclosure to be cable connected to the<br />

panel. Sangamo, Tork or Paragon time<br />

clock can be supplied and mounted in<br />

panelboard cabinet. Adds 12" to panel<br />

height. Mounts in Sub-area.<br />

Description<br />

Time Clock (1 or 2-pole, single or double<br />

throw contacts; 3-pole, single throw)<br />

277V maximum with plain dial<br />

Astronomical dial<br />

An omitting device<br />

Reserve power or carryover<br />

Space and mounting<br />

provisions only<br />

a Accessories on 1" pole breakers (BL, BQD, ED) will take<br />

unit space.<br />

11-46<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category PBSB


Panelboards<br />

Type P3 Panelboard Standard Modifications<br />

Selection<br />

Option Combinations<br />

Subfeed Feed-thru FD a JD a FD b 200% Min. Box Unit Space<br />

Amps Incoming Lugs Lugs Subfeed Subfeed Subfeeds Neutral Size (in.) (in.)<br />

• — — — • 56 27<br />

Main Lug Only — — • — — • 56 15<br />

— — — • • 56 9<br />

• — — — • 56 21<br />

Main Lugs w/Subfeed Lugs • — • — — • 56 21<br />

250 — — — • • 62 9<br />

Main Breaker (Horiz. FD) —<br />

• — — — • 56 21<br />

— • — — • 56 9<br />

Main Breaker (Vert. FD) None Std. • — — — • 56 15<br />

Main Breaker (CFD)<br />

None Std.<br />

• — — — • 56 9<br />

— • — — • 68 9<br />

• — — — — • 56 21<br />

— • — — — • 56 15<br />

Main Lug Only — — • — — • 56 9<br />

— — — • — • 56 9<br />

— — — — • • 62 9<br />

— — — — • 56 9<br />

• — — — • 62 9<br />

400 bc Main Breaker (JD) None Std. — • — — • 68 9<br />

— — • — • 68 9<br />

— — — • • 74 9<br />

— — — — • 62 9<br />

• — — — • 74 9<br />

Main Breaker (CJD) None Std — • — — • 74 9<br />

— — • — • 74 9<br />

— — — • • 80 9<br />

— — — — • 56 21<br />

• — — — • 56 15<br />

Main Lug Only — — • — — • 56 9<br />

— — • — — 56 9<br />

— — — • • 62 9<br />

— — — — • 56 9<br />

• — — — • 62 9<br />

600 bc Main Breaker LD — — • — — • 68 9<br />

— — • — — 68 9<br />

— — — • • 74 9<br />

— — — — • 62 9<br />

• — — — • 68 9<br />

Main Breaker CLD — — • — — • 74 9<br />

— — • — — 74 9<br />

— — — • • 80 9<br />

— — — — • 56 21<br />

• — — — • 56 9<br />

800 bc Main Lug Only — — • — — • 56 9<br />

— — • — — 56 9<br />

— — — • • 62 9<br />

11 PANELBOARDS<br />

a Subfed lugs are currently not offered as standard with<br />

main circuit breakers.<br />

b Subfed lugs on panels above 400A are not standard.<br />

c 200% neutral cannot be provided along with a 400A<br />

subfeed breaker because the breaker blocks the 4th<br />

lug site.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-47


Panelboards<br />

Type P3 Panelboard Modifications and Additions<br />

Revised on 04/30/19<br />

Selection<br />

11<br />

PANELBOARDS<br />

Compression Lugs<br />

Amp Breaker<br />

Compression<br />

Box Height<br />

Style Rating Type<br />

Connectors<br />

Addition<br />

250 N/A (1)#6 AWG - 350 kcmil —<br />

MLO<br />

Main<br />

Breaker<br />

400 N/A<br />

(1) 250 - 500 kcmil or<br />

(2)# 1/0 AWG - 250 kcmil<br />

600 N/A (2)#3/0 AWG - 500 kcmil —<br />

800 N/A (2) 400-750 kcmil Cu only —<br />

250 FXD6, HFD6, CFD6 (1)#6 AWG - 350 kcmil Cu or Al<br />

CFD6 requires an<br />

additional 6.0" box height<br />

400<br />

JD6, JXD6, HJD6, CJD6,<br />

SJD6, SHJD6, SCJD6<br />

(2)#1/0 AWG - 500 kcmil Cu or Al —<br />

600<br />

LD6, LXD6, HLD6, CJD6,<br />

SLD6, SHLD6, SCLD6<br />

(2)#2/0 AWG - 500 kcmil Cu or Al —<br />

—<br />

—<br />

Alternate Lugs<br />

Amp<br />

Style Rating<br />

MLO<br />

Main<br />

Breaker<br />

Enclosure Modifications<br />

24" Panel Width<br />

Description<br />

NEMA 3R enclosures<br />

NEMA 3R/12 enclosures a<br />

Gasket between trim<br />

and box (Type 1)<br />

Breaker<br />

Type<br />

400 N/A<br />

Standard AL<br />

Connectors<br />

(1) 250 - 750 kcmil or<br />

(2)#3/0 AWG - 250 kcmil Cu or Al<br />

800 N/A (3)#4-500 Kcmil CU or Al capacity 6<br />

400<br />

JD6, JXD6, HJD6, CJD6,<br />

SJD6, SHJD6, SCJD6<br />

(1)#4/0 AWG - 750 kcmil Cu or Al 6<br />

Box Height<br />

Addition<br />

6<br />

NEMA-4X For Type P3 <br />

Water Tight, Dust Tight and Corrosion Resistant<br />

(consult plant for actual enclosure size and for<br />

NEMA 4 enclosures)<br />

Box Height Enclosure – Stainless Steel<br />

Inches H W D<br />

56 56 24 7.75<br />

62 62 24 7.75<br />

68 68 24 7.75<br />

74 74 24 7.75<br />

80 80 24 7.75<br />

a 16 Gauge Cans w/ 14 Gauge Front)<br />

b 14 Gauge only<br />

c 14 Gauge only - 304SS Std, 316SS Optional)<br />

11-48<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category PBSB


Panelboards<br />

Type P3 Panelboard Kits and Accessories<br />

Revised on 04/30/19<br />

Selection<br />

Standard Enclosures<br />

Box<br />

Height<br />

(in.)<br />

Catalog Number<br />

Type 1<br />

Standard Trim<br />

Box Surface Flush Type 3R Type 3R/12<br />

56 24WD56 P3S56 P3F56 24NRD56 24WPD56<br />

62 24WD62 P3S62 P3F62 24NRD62 24WPD62<br />

68 24WD68 P3S68 P3F68 24NRD68 24WPD68<br />

74 24WD74 P3S74 P3F74 24NRD74 24WPD74<br />

80 24WD80 P3S80 P3F80 24NRD80 24WPD80<br />

Options For Type 1 Trims<br />

Items must be ordered as manual line item on factory<br />

Hinged trim – Add “H” suffix<br />

Door-in-door – Add “D” suffix<br />

Metal card holder – Add “M” suffix<br />

11 PANELBOARDS<br />

Breaker Kits and Accessories<br />

Kit Number Description Contents<br />

BBKB32 (P2/P3) BL/BQD 6-pole 3" branch breaker kit Kit contains top barrier, (3) A/C connectors, (1) B connector, hardware<br />

BBKNB32 (P2/P3) NGB, HGB, LGB 6-pole 3" branch breaker kit Kit contains top barrier, (3) A/C connectors, (1) B connector, hardware<br />

BBKGB32 (P2/P3) NGB2, HGB2, LGB2 6-pole 3" branch breaker kit Kit contains top barrier, (3) A/C connectors, (1) B connector, hardware<br />

BBKEB32 (P3) NEB/HEB 6-pole 3" branch breaker kit Kit contains top barrier, (3) A/C connectors, (1) B connector, hardware<br />

BBKED32 (P2/P3) ED 6-pole 3" branch breaker kit<br />

Kit contains breaker support, inter-phase barriers, (3) A/C connectors,<br />

(1) B connector, hardware<br />

BBKQ2 (P3) Branch breaker kit for 2 and 3-pole QJ twin mount<br />

Kit contains all connectors and cover plates necessary to mount both 2 and<br />

3-pole breakers<br />

BBKQR2 ac P3 twin BKR mounting kit for QR 1-phase/3-phase<br />

Kit contains all connectors and cover plates necessary to mount both 2 and<br />

3-pole breakers (limit 6 QR per panel)<br />

BBKVA52P3T c P3 strap kit; twin mount 3VA52 branch<br />

Uses 6" of unit space. Includes 2x BBKVA52P3HW, barrier, straps, &<br />

mounting hardware.<br />

BBKA52P3HW P3 branch breaker hardware kit Includes screw retainers & mounting screws.<br />

DFFP3 Deadfront filler 3" 3" empty space filler and hardware<br />

DFFP6 Deadfront filler 6" 6" empty space filler and hardware<br />

P3BK1 P3 bonding kit 800A max MLO+MB Bonding strap and hardware. For all MLO+MB configurations.<br />

EBF1 HEB/NEB Filler Plate Filler Plate<br />

BBKQRP2FK<br />

Kit contains all cover plates necessary to change from QJ to QR both 2 and<br />

P3 Filler for QR. Dual mount horizontal.<br />

3-pole breakers. For 1-phase panel, both breakers must change from QJ to<br />

1-phase/3-phase.<br />

QR, cannot have one of each installed.<br />

SEBKP3V1 b Service entrance barrier kit CFD, FD (P3 only) Kit contains barrier, mounting brackets, and hardware<br />

SEBKP1P2P3V1 b JD, LD Service Entrance Barrier Kit (RP1, P1, P2, P3) Kit contains barrier, mounting brackets, and hardware<br />

SEBKP2V3<br />

FD, QJ, QR Horizontal Main Service Entrance Barrier<br />

(P2, P2 with SEM3, P3)<br />

Kit contains barrier, mounting brackets, and hardware<br />

Although QR is rated 250A, it is limited to 225A in panelboard.<br />

b Factory installed and Field installable Service Entrance Barrier kits are now available as required by UL67. (In COMPAS, you must select Service Entrance Required.)<br />

c Maximum 6 large frame breakers in unit space. (QR + 3VA52)<br />

Type P1, P2, and P3 Panelboards<br />

Miscellaneous Parts and Accessories<br />

Catalog Number Description<br />

EGK<br />

Al Ground Bus 44 Connections<br />

BK1<br />

Bonding kit for 250A max. and all P1 panels<br />

IMK1<br />

Interior Adjusting Kit<br />

LPDC01 Directory Card (Pack of 10; ref. 12-1110-01)<br />

LPDC02 Directory Card Holder (Pack of 10; ref. 11-1824-01)<br />

NBK3<br />

Number Strips 1-42. Snap-in type; Use w/P2 & P3 series Panels<br />

NBK4<br />

Number Strips 43-84. Snap-in type; Use w/P2 & P3 series Panels<br />

NBK5<br />

Number Strips 85-126. Snap-in type; Use w/P2 & P3 series Panels<br />

NBK6<br />

Number Strips 127-168. Snap-in type; Use w/P2 & P3 series Panels<br />

NBK7<br />

Number Strips 169-210. Snap-in type; Use w/P2 & P3 series Panels<br />

NBK8<br />

Number Strips 211-252. Snap-in type; Use w/P2 & P3 series Panels<br />

ECGK<br />

Cu Ground Bus 44 Connections<br />

IGK<br />

Insulated Al Ground Bus<br />

ICGK<br />

Insulated Cu Ground Bus<br />

EWK2<br />

End Wall Kit with Knockouts (24" W x 7.75" DP)<br />

DFFP1<br />

1" Filler Plate (used for BL/BQD/xGB/xGB2/ED blank positions) (Suitable for replacing QF3 in<br />

P1 thru P5 Panelboards and Switchboards)<br />

ANSI/NEMA<br />

PB 1.1-2013<br />

General Instructions for Proper Installation, Operation, and Maintenance of Panelboards<br />

Rated 600 Volts or Less (O&M Manual) a<br />

PDF can be downloaded (at no cost) and printed at this location: http://www.nema.org/standards/pages/Panelboards.aspx<br />

Product Category PBSB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-49


Panelboards<br />

Type P3 Panelboards<br />

Revised on 04/30/19<br />

Dimensions<br />

11<br />

PANELBOARDS<br />

Type 1 Box<br />

Box is symmetrical<br />

0.313 in. Dia.<br />

0.313 in. Dia.<br />

(UL approved construction. 16 gage steel or equivalent alternate construction.<br />

14 or 12 gage is available as an optional special order.)<br />

G60 Galvanized is standard without paint.<br />

Type 3R and 3R/12 Box<br />

10.0<br />

[254]<br />

10.0<br />

[254]<br />

(Mounting Holes<br />

0.437 in. Square)<br />

(Mounting Holes<br />

0.437 in. Square)<br />

(Mounting Holes<br />

0.437 in. Square)<br />

(Mounting Holes<br />

0.437 in. Square)<br />

(Mounting Holes<br />

0.437 in. Square)<br />

(Mounting Holes<br />

0.437 in. Square)<br />

(Mounting Holes<br />

0.437 in. Square)<br />

(Mounting Holes<br />

0.437 in. Square)<br />

27.0 in.<br />

[ 686 ]<br />

27.0 in.<br />

(UL approved construction. 16 gage steel can with<br />

[ 686 ]<br />

14 gage front or similar approved construction.)<br />

A60 Galvannealed with ANSI 61 light gray paint is standard.<br />

a Dimensions are interior of the box. Add 5/8" to width for absolute<br />

dimension. Add 1/8" to height for absolute dimension.<br />

Dimensions shown in inches and millimeters [ ].<br />

11-50<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Breaker Configuration Information in Panelboards<br />

Revised on 02/29/20<br />

3VA breaker Accessories Information<br />

Selection<br />

Panelboard Specific 3VA Accessories Available in Panelboards<br />

3VA Series Accessories<br />

There are 4 positions on each side of<br />

the trip handle of the 3VA52 breaker.<br />

Accessories can be 1, 2 or 3 positions<br />

wide and fit in specific locations as<br />

shown on charts and on the inside<br />

cover of each breaker.<br />

Accessory types:<br />

3VA breaker auxiliary releases allow<br />

remote electrical tripping of the circuit<br />

breaker<br />

n STL – Shunt Trip Left<br />

n STF – Shunt Trip Flexible<br />

n UVR – Undervoltage Releases Trip<br />

3VA UL Molded Case Circuit Breakers<br />

n<br />

Accessories UNI – Universal and Spare Release Parts - Shunt<br />

Trip and an Undervoltage Release<br />

Internal are Combined accessories<br />

■ Overview<br />

Color coding of accessories<br />

STL<br />

UVR<br />

UNI<br />

All Auxiliary and Alarm Switches for<br />

3VA breakers belong to an integrated<br />

range of accessories<br />

n AUX_HQ / AUX_HP – Auxiliary<br />

Switches<br />

n LCS_HQ / LCS_HP – Leading<br />

Changeover Switches<br />

n TAS_HQ / TAS_HP – Trip Alarm<br />

Switches<br />

n EAS_HQ / EAS_HP – Electrical<br />

alarm switches<br />

3VA Auxiliary and Alarm Switches<br />

have standard (HQ) and high capacity<br />

(HP) types as well as “electronic”<br />

versions for example: AUX_HQ_el<br />

* Padlock accessory will be available<br />

in a future release.<br />

LCS<br />

EAS<br />

3VA52 Breaker Features<br />

3VA Internal Breaker<br />

Accessories configurations<br />

TMTU<br />

Thermal-Magnetic trip<br />

Accessory Slots<br />

Frame<br />

width<br />

Amp<br />

range<br />

3VA41 - 1-pole 1p 15-125 0<br />

3VA41 - 1-pole in 2p frame<br />

3<br />

3VA41 - 2-pole<br />

2p 15-125<br />

3<br />

3VA41 - 3-pole 3p 15-125 6<br />

3VA51 - 1-pole 1p 15-125 0<br />

3VA51 - 1 pole in 2p frame 2p 15-125 3<br />

3VA51 - 2 pole in 3p frame<br />

6<br />

3VA51 - 3-pole<br />

3p 15-125<br />

6<br />

3VA51 - 3-pole MCS 3p 100 6<br />

3VA52 - 2-pole in 3p frame<br />

8<br />

3VA52 - 3-pole<br />

3p 100-250<br />

8<br />

3VA52 - 3-pole MCS 3p 100-250 8<br />

3VA53 - 3-pole 3p 200-400 10<br />

ETU - Electronic Trip*<br />

3VA61 - 3 pole 3p 16-150 8<br />

3VA62 - 3-pole 3p 40-250 8<br />

3VA63 - 3-pole 3p 100-400 10<br />

3VA64 - 3-pole 3p 160-600 10<br />

11 PANELBOARDS<br />

* 100% rated may have reduced ranges<br />

3VA6 ETU only<br />

STF<br />

COM060<br />

24 V module Lock adapter for<br />

mounting the<br />

cylinder lock<br />

AUX<br />

TAS<br />

I201_19551<br />

A color coding system has been used to clearly identify the<br />

specific functions of individual accessories:<br />

Color Auxiliary switches and alarm switches Auxiliary releases<br />

Black Auxiliary switch AUX • Shunt trip left STL<br />

• Shunt trip flexible STF<br />

Gray Leading changeover switch LCS • Undervoltage release UVR<br />

Yellow Trip alarm switch TAS --<br />

Green Electrical alarm switch EAS --<br />

Blue -- Universal release UNI<br />

Auxiliary switches<br />

All auxiliary and alarm switches for the 3VA UL molded case<br />

circuit breakers belong to an integrated range of accessories.<br />

The auxiliary switches can be simply snapped into place and<br />

connected up in the accessories compartment provided on the<br />

front face of the unit to the left and right of the handle.<br />

The purpose of the auxiliary switches (AUX) is to signal the<br />

position of the main contacts of the molded case circuit breaker.<br />

The contacts of the auxiliary switches open and close<br />

simultaneously with the main contacts of the molded case circuit<br />

breaker.<br />

Leading changeover switches (LCS) signal the opening of the<br />

Auxiliary releases<br />

Auxiliary releases allow remote electrical tripping of the circuit<br />

breaker. They can be used to monitor control or main circuits in<br />

order to implement 3VA a accessories protective system install against easily. accidental<br />

restart following a power failure, for example.<br />

Special Hardware kit for P3 Twin Mount aligns screw<br />

Undervoltage<br />

for<br />

releases<br />

easy<br />

trip<br />

installation.<br />

the 3VA UL molded case circuit<br />

breaker in the event that the rated voltage of a monitored circuit<br />

drops below a minimum permissible limit or fails altogether.<br />

Shunt trips can be used Siemens to trip Industry, the 3VA Inc. UL SPEEDFAX molded case Product circuit Catalog 11-51<br />

breaker remotely. The STF variant can be mounted in either the<br />

left-hand or the right-hand accessories compartment (for 3VA6<br />

only). The STL type is specifically designed for mounting in the


Revised on 02/29/20<br />

3VA Breaker Configuration Information in Panelboards<br />

P1 Lighting Panel General information<br />

Minimum enclosure size: 20" wide x 5.75" deep<br />

11<br />

PANELBOARDS<br />

P1 Lighting Panelboard<br />

P1 interiors have unit space setup for either:<br />

A) BL/BQD type of breakers only<br />

or<br />

B) xGB and 3VA41 breakers only in same interior<br />

(no BL/BQD allowed)<br />

Deadfront Supports<br />

Neutral Riser<br />

Neutral Strips:<br />

1/0 max. factory<br />

assembled<br />

(BL/BQD)<br />

2/0 max.<br />

available for<br />

field install<br />

2/0 max. std.<br />

for xGB/3VA41<br />

A/C-Phase<br />

Connector<br />

- CU or AL<br />

Base Rails<br />

Main Space<br />

P1 Lighting Panel<br />

P1 Main Space can include:<br />

Main Lugs: 250A or 400A max<br />

Main Breaker Types:<br />

n 100A max BL/BQD & 125A max. xGB or ED<br />

n 125A max. 3VA41 (TMTU)<br />

(horiz. mount)<br />

n 225A max. QR series (horizontal mount)<br />

n 250A max. FD series (horizontal mount)<br />

n 400A max. 3VA53/63 (TMTU/ETU)<br />

(vertical mount)<br />

(ETU = Electronic Trip Unit)<br />

(TMTU = Thermal Magnetic Trip Unit)<br />

n 400A max. JD series (vertical mount)<br />

Future 3VA offering in development:<br />

n 250A max. 3VA52/62 (TMTU/ETU)<br />

(horiz. mount)<br />

P1 Branch Breakers — Small Frame only:<br />

a) 100A max BL series<br />

b) 100A max BQD series<br />

c) 125A max xGB or 3VA41<br />

series after 3/1/2020<br />

(Cannot Mix with BL/BQD)<br />

Note: always check dead front labels<br />

for allowed breakers<br />

B-Phase<br />

Connector<br />

- CU or AL<br />

Bus Bars:<br />

250A - CU or AL<br />

400A - CU or AL<br />

Subfeed Space<br />

P1 Subfeed Space offering:<br />

Feed-thru Lugs:<br />

A) 250A or 400A<br />

B) Surge Protection Devices (SPD)<br />

C) Subfeed Breakers:<br />

– 250A max. horizontal mounnt FD<br />

– 225A max. QR<br />

– 100A max. BL/BQD<br />

– 125A max. xGB/3VA41/ED<br />

Future 3VA offering in development:<br />

– 250A max. 3VA52 TMTU<br />

– 250A max. 3VA62 ETU<br />

– Horizontal mount only<br />

11-52<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Revised on 02/29/20<br />

3VA Breaker Configuration Information in Panelboards<br />

P2 Lighting Panel General information<br />

Minimum enclosure size: 20" wide x 5.75" deep<br />

P2 Lighting Panelboard<br />

P2 interiors have flexible unit space setup for<br />

Multiple Branch Breaker Types and many different<br />

Main/Subfeed options.<br />

Neutral Cross<br />

Strap<br />

– positions for<br />

mounting<br />

Neutral lugs<br />

– many different<br />

configurations<br />

are used.<br />

Neutral Strips:<br />

1/0 max. cable size<br />

"Step lugs" and other<br />

varieties depending<br />

on the configuration<br />

– factory assembled<br />

only<br />

– optional field installable<br />

kits may be added in<br />

near future to include<br />

2/0 capability.<br />

Various Branch<br />

Breaker Strap<br />

Kits installed<br />

Field installable<br />

Neutral Extension<br />

can be added for<br />

AFCI/GFCI when<br />

needed due to<br />

short pigtails. It<br />

can be positioned<br />

anywhere along<br />

the base rail on<br />

either side.<br />

kit # BNKP2EX1<br />

BNKP2EX1<br />

Deadfront Supports<br />

Base Rails<br />

Main Space<br />

P2 Lighting Panel<br />

P2 Main Space can include:<br />

Main Lugs: 125A, 250A, 400A or 600A<br />

==> also Subfeed Lugs: 125A, 250A or 400A<br />

Main Breaker Types:<br />

n 100A max. BL/BQD or 125A max. xGB or ED<br />

n 250A max. FD series (horizontal mount)<br />

n 400A max. JD series (vertical mount)<br />

n 600A max. LD series (vertical mount)<br />

Future 3VA offering in development:<br />

n 250A max. 3VA52/62 (TMTU/ETU)<br />

(horiz. mount)<br />

n 400A max. 3VA53/63 (TMTU/ETU)<br />

(vertical mount)<br />

n 600A max. 3VA54/64 (TMTU/ETU)<br />

(vertical mount)<br />

(ETU = Electronic Trip Unit)<br />

(TMTU = Thermal Magnetic Trip Unit)<br />

P2 Branch Breakers — Small Frame:<br />

a) 100A max BL series<br />

b) 100A max BQD series<br />

c) Various AFCI/GFCI series<br />

d) 125A max ED series (480V delta capable)<br />

e) 125A max xGB series<br />

f) 125A max GB2 series<br />

(480V delta capable)<br />

Future 3VA offering in development:<br />

g) 125A max. 3VA41 TMTU<br />

(480V delta capable)<br />

P2 Branch Breakers — Large Frame<br />

(6 max.)<br />

1) 225A max QR series (total 225A/250A<br />

frame, four per panel limit)<br />

Future 3VA offering in development:<br />

2) 150A max 3VA61 ETU single mount<br />

3) 250A max 3VA52/62 TMTU/ETU<br />

single mount<br />

11 PANELBOARDS<br />

Bus Bars:<br />

250A - CU or AL<br />

400A - CU or AL<br />

600A - CU or AL<br />

Subfeed Space offering:<br />

Feed-thru Lugs:<br />

A) 125A, 250A, 400A, or 600A<br />

B) Surge Protection Devices (SPD)<br />

C Subfeed Breakers:<br />

– 250A max. FD twin mount vertical<br />

– 400A max. JD single mount vertical<br />

Future 3VA offering in development:<br />

– 400A max. 3VA53/63 (TMTU/ETU)<br />

(vertical single mount)<br />

Subfeed Space<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-53


Revised on 04/30/19<br />

3VA Breaker Configuration Information in Panelboards<br />

P3 Lighting Panel General information<br />

Minimum enclosure size: 24" wide x 7.75" deep<br />

11<br />

PANELBOARDS<br />

P3 Lighting Panelboard<br />

P3 interiors have flexible unit space setup for<br />

Multiple Branch Breaker Types and many different<br />

Main/Subfeed options.<br />

Main Lugs shown<br />

installed<br />

Deadfront Supports<br />

Base Rails<br />

P3 Lighting Panel<br />

P3 Main Space can include:<br />

Main Lugs: 250A, 400A, 600A or 800A<br />

==> also Subfeed Lugs: 250A or 400A<br />

Main Breaker Types:<br />

n 250A max. FD series (horizontal mount)<br />

n 400A max. JD series (vertical mount)<br />

n 600A max. LD series (vertical mount)<br />

Neutral Cross<br />

Straps<br />

– top and bottom<br />

– positions for<br />

mounting up to<br />

four 350 kcmil<br />

Neutral lugs<br />

each<br />

Neutral Strips:<br />

1/0 max. cable<br />

currently<br />

– factory assembled<br />

only<br />

– optional field<br />

installable kits<br />

may be added<br />

in near future to<br />

include 2/0 max.<br />

capacity neutral<br />

kits.<br />

Various Branch<br />

Breaker Strap Kits<br />

installed<br />

Bus Bars:<br />

250A - CU or AL<br />

400A - CU or AL<br />

600A - CU or AL<br />

800A - CU or AL<br />

Neutral Cross<br />

Straps<br />

P3 interior is similar<br />

to P2 but has a 2 inch<br />

high riser to allow for<br />

larger Breakers and<br />

additional gutter space.<br />

Main Space<br />

Subfeed Space<br />

Future 3VA offering in development:<br />

n 250A max. 3VA52/62 (TMTU/ETU)<br />

(horizontal mount)<br />

n 400A max. 3VA53/63 (TMTU/ETU)<br />

(vertical mount)<br />

n 600A max. 3VA54/64 (TMTU/ETU)<br />

(vertical mount)<br />

(ETU = Electronic Trip Unit)<br />

(TMTU = Thermal Magnetic Trip Unit)<br />

P3 Branch Breakers — Small Frame:<br />

a) 100A max BL series<br />

b) 100A max BQD series<br />

c) Various AFCI/GFCI series<br />

d) 125A max ED series (480V delta capable)<br />

e) 125A max xGB series<br />

f) 125A max GB2 series (480V delta capable)<br />

Future 3VA offering in development:<br />

g) 125A max. 3VA41 TMTU (480V delta<br />

capable<br />

P3 Branch Breakers — Large Frame<br />

(6 max.)<br />

1) 225A max QR series (twin mount)<br />

2) 250A max 3VA52 Series (twin Mount)<br />

(total 225A/250A frame, 6 per panel limit)<br />

Future 3VA offering in development:<br />

3) 250A max 3VA62/3VA61 ETU single<br />

mount<br />

New 3VA offering has many field<br />

installable accessories available.<br />

P3 Subfeed Space offering:<br />

Feed-thru Lugs:<br />

A) 225A/250A, 400A, 600A or 800A<br />

B) Surge Protection Devices (SPD)<br />

C) Subfeed Breakers:<br />

– 250A max. FD twin mount vertical<br />

– 400A max. JD single mount vertical<br />

Future 3VA offering in development:<br />

– 250A max. 3VA52/62 (TMTU/ETU)<br />

(vertical twin mount)<br />

– 400A max. 3VA53/63 (TMTU/ETU)<br />

(vertical single mount)<br />

11-54<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Revised on 02/29/20<br />

3VA Breaker Configuration Information in Panelboards<br />

P4 Power Panel General information<br />

Minimum enclosure size: 32" wide x 10" deep<br />

P4 Power Panel<br />

P4 interiors have unit space setup for Multiple Branch<br />

Breaker Types and many different Main Breaker options.<br />

Neutral<br />

Connections*<br />

– at Main end<br />

of panel<br />

– Various configurations.<br />

* Depends on<br />

breaker selection<br />

- Consult factory<br />

for details<br />

Main Lugs<br />

shown<br />

installed<br />

Main Space<br />

– Mains are mounted<br />

in unit space<br />

– All are horizontal mount<br />

Vented Front Cover<br />

P4 Power Panel<br />

P4 Main Space can include:<br />

Main Lugs: 400A, 600A, 800A,<br />

1000A or 1200A<br />

Main Breaker Types: (horizontal mount)<br />

n 100A max. BL/BQD or 125A max. xGB or ED<br />

n 400A max. JD and VL-JG series<br />

n 600A max. LD and VL-LG series<br />

n 800A max. LM and VL-MG series<br />

Future 3VA offering in development:<br />

n 400A max. 3VA53/63 (TMTU/ETU)<br />

n 600A max. 3VA54/64 (TMTU/ETU)<br />

n 800A max. 3VA55/65 (TMTU/ETU)<br />

(ETU = Electronic Trip Unit)<br />

(TMTU = Thermal Magnetic Trip Unit)<br />

11 PANELBOARDS<br />

SEM3 CT's<br />

installed<br />

Various<br />

Branch<br />

Breaker<br />

Strap Kits<br />

installed<br />

Bus Bars:<br />

CU or AL<br />

SEM3<br />

Controller<br />

and Meter<br />

module<br />

racks<br />

P4 Unit Space<br />

below Bus:<br />

There is no<br />

actual Subfeed<br />

space.- All<br />

Space is unit<br />

space, but at<br />

the bottom<br />

below the<br />

bus, there can<br />

be additional<br />

components<br />

such as the<br />

SEM3 devices<br />

shown.<br />

Unit Space<br />

below Bus<br />

P4 Branch Breakers — Small Frame:<br />

a) 100A max BL series<br />

(10, 22, 65 kaic @ 240V)<br />

b) 100A max BQD series<br />

(14 kaic @ 480/277V)<br />

c) Various AFCI/GFCI series<br />

d) 125A max ED series (480V delta capable)<br />

e) 125A max xGB seriesf) 125A max<br />

GB2 series (480V delta capable)<br />

Future 3VA offering in development:<br />

g) 125A max. 3VA41 TMTU<br />

(480V delta capable)<br />

P4 Branch Breakers — Large Frame<br />

(6 max.)<br />

1) 150A max VL-DG series<br />

2) 150A 3VA61 ETU Series (new 2019)<br />

3) 225A max QR series<br />

4) 250A max FD or VL-FG series<br />

5) 250A max 3VA52/62 TMTU/ETU (new 2019)<br />

6) 400A max JD and VL-JG series<br />

7) 600A max. LD and VL-LG series<br />

8) 800A max. MD and VL-MG series<br />

Future 3VA offering in development:<br />

9) 400A max. 3VA53/63 (TMTU/ETU)<br />

10) 600A max. 3VA54/64 (TMTU/ETU)<br />

11) 800A max. 3VA55/65 (TMTU/ETU)<br />

New 3VA offerings have many field<br />

installable accessories available including<br />

strap kits.<br />

(See Strap Kit Table page 11-77).<br />

Vented Front Cover<br />

P4 Standard Box Width is 32" W<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-55


Revised on 02/29/20<br />

3VA Breaker Configuration Information in Panelboards<br />

P5 Power Panel General information<br />

Minimum enclosure size: 38" wide x 10" deep<br />

11<br />

PANELBOARDS<br />

P5 Power Panel<br />

P5 interiors have unit space setup for Multiple Branch<br />

Breaker Types and many different Main Breaker options.<br />

Neutral<br />

Connections*<br />

– at Main end<br />

of panel<br />

– Various configurations.<br />

* Depends on<br />

breaker selection<br />

- Consult factory<br />

for details<br />

Main Lugs<br />

shown<br />

installed<br />

SEM3 CT's<br />

installed<br />

Various<br />

Branch<br />

Breaker<br />

Strap Kits<br />

installed<br />

Bus Bars:<br />

CU or AL<br />

Main Space<br />

– Mains are mounted<br />

in unit space<br />

– All are horizontal mount<br />

Vented Front Cover<br />

P5 Power Panel<br />

P4 Main Space can include:<br />

Main Lugs: 400A, 600A, 800A,<br />

1000A or 1200A<br />

Main Breaker Types: (horizontal mount)<br />

n 400A max. JD and VL-JG series<br />

n 600A max. LD and VL-LG series<br />

n 800A max. LM and VL-MG series<br />

n 1200A max. ND and VL-NG series<br />

Future 3VA offering in development:<br />

n 400A max. 3VA53/63 (TMTU/ETU)<br />

n 600A max. 3VA54/64 (TMTU/ETU)<br />

n 800A max. 3VA55/65 (TMTU/ETU)<br />

(ETU = Electronic Trip Unit)<br />

(TMTU = Thermal Magnetic Trip Unit)<br />

P5 Branch Breakers — Small Frame:<br />

a) 100A max BL series<br />

b) 100A max BQD series<br />

c) Various AFCI/GFCI series<br />

d) 125A max ED series<br />

(480V delta capable)<br />

d) 125A max xGB series<br />

e) 125A max GB2 series<br />

(480V delta capable)<br />

Future 3VA offering in development:<br />

f) 125A max. 3VA41 TMTU<br />

(480V delta capable)<br />

SEM3<br />

Controller<br />

and Meter<br />

module<br />

racks<br />

P5 Unit Space<br />

below Bus:<br />

There is no<br />

actual Subfeed<br />

space.- All<br />

Space is unit<br />

space, but at<br />

the bottom<br />

below the<br />

bus, there can<br />

be additional<br />

components<br />

such as the<br />

SEM3 devices<br />

shown.<br />

Unit Space<br />

below Bus<br />

P5 Branch Breakers —<br />

Large Frame (6 max.)<br />

1) 150A max VL-DG series<br />

2) 150A 3VA61 ETU Series (new 2019)<br />

3) 225A max QR series<br />

4) 250A max FD or VL-FG series<br />

5) 250A max 3VA52/62 TMTU/ETU<br />

(new 2019)<br />

6) 400A max JD and VL-JG series<br />

7) 600A max. LD and VL-LG series<br />

8) 800A max. MD and VL-MG series<br />

9) 1200A max. ND and VL-NG series<br />

Future 3VA offering in development:<br />

10) 400A max. 3VA53/63 (TMTU/ETU)<br />

11) 600A max. 3VA54/64 (TMTU/ETU)<br />

12) 800A max. 3VA55/65 (TMTU/ETU)<br />

(See Strap Kit Table page 11-91).<br />

Vented Front Cover<br />

P5 Standard Box Width is 38" W<br />

11-56<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Breaker Configuration Information in Panelboards<br />

Revised on 02/29/20<br />

3VA Electronic Trip Units<br />

Selection<br />

3VA6 ETU – "Electronic Trip" versions of 3VA Breakers used in Panelboards<br />

n See following pages for internal accessory pocket locations available in TMTU & ETU versions<br />

n Standard part number shown for base trip unit - other variations available shown in lower chart<br />

n Breakers shown do not include lugs - lugs are ordered separately as needed per application<br />

n COMPAS will allow various Lug configurations based on Panel Type and mounting location<br />

11 PANELBOARDS<br />

For Accessories<br />

and positions see<br />

tables on pages<br />

11-64 and 11-68<br />

Connector Kits for 3 Pole 3VA6 series Breakers<br />

Description<br />

note: Use 3-pole for<br />

2-pole applications<br />

Connector Kits AL CU<br />

3 Pole 3VA6 series Breakers without connectors<br />

Standard in COMPAS includes ETU350 LSI Trip<br />

(Ir and Ii are adjustable)<br />

One Connector Kit<br />

required for each<br />

breaker when panel<br />

mounted.<br />

ETU350 LSI<br />

included<br />

3VA61/62 3VA9243-0JB12 3VA9243-0JD12<br />

3VA63 3VA9373-0JB13 3VA9373-0JD13<br />

3VA64<br />

ETU350 LSI<br />

included<br />

ETU350 LSI<br />

included<br />

ETU350 LSI<br />

included<br />

kA ratings @ 50/60 Hz 3-pole 3-pole 3-pole 3-pole<br />

240 VAC kAIC rating ==> 100 100 200 200<br />

480Y / 277 VAC kAIC rating ==> 35 65 100 150<br />

480 VAC kAIC rating ==> 35 65 100 150<br />

600Y / 347 VAC kAIC rating ==> 18 22 35 50<br />

600 VAC kAIC rating ==> 18 22 35 50<br />

250 VDC kAIC rating ==> na na na na<br />

amps Adj. Ir code<br />

3VA61 UL Type Code / MB code ==> MDAE / W2 HDAE / W3 CDAE / W4 LDAE a / W5<br />

40 16-40 40 3VA61 3P breaker w/trip 3VA6140-5HN31-0AA0 3VA6140-6HN31-0AA0 3VA6140-7HN31-0AA0 3VA6140-8HN31-0AA0<br />

100 40-100 10 3VA61 3P breaker w/trip 3VA6110-5HN31-0AA0 3VA6110-6HN31-0AA0 3VA6110-7HN31-0AA0 3VA6110-8HN31-0AA0<br />

150 60-150 15 3VA61 3P breaker w/trip 3VA6115-5HN31-0AA0 3VA6115-6HN31-0AA0 3VA6115-7HN31-0AA0 3VA6115-8HN31-0AA0<br />

3VA62 UL Type Code / MB code ==> MFAE / WA HFAE / WB CFAE / WC LFAE a / WD<br />

100 40-100 10 3VA62 3P breaker w/trip 3VA6210-5HN31-0AA0 3VA6210-6HN31-0AA0 3VA6210-7HN31-0AA0 3VA6210-8HN31-0AA0<br />

250 100-250 25 3VA62 3P breaker w/trip 3VA6225-5HN31-0AA0 3VA6225-6HN31-0AA0 3VA6225-7HN31-0AA0 3VA6225-8HN31-0AA0<br />

3VA63 UL Type Code / MB code ==> MJAE / WE HJAE / WF CJAE / WG LJAE a / WH<br />

250 100-250 25 3VA63 3P breaker w/trip 3VA6325-5HN31-0AA0 3VA6325-6HN31-0AA0 3VA6325-7HN31-0AA0 3VA6325-8HN31-0AA0<br />

400 160-400 40 3VA63 3P breaker w/trip 3VA6340-5HN31-0AA0 3VA6340-6HN31-0AA0 3VA6340-7HN31-0AA0 3VA6340-8HN31-0AA0<br />

3VA63 MCS UL Type Code / MB code ==> na na CJAE / WG na<br />

400 na 40 3VA63 3P Molded Case Sw non adj. short circuit release I i ==> 3VA6340-1BB31-0AA0 na<br />

3VA64 UL Type Code / MB code ==> MLAE / WJ HLAE / WK CLAE / WL LLAE a / WM<br />

400 160-400 40 3VA64 3P breaker w/trip 3VA6440-5HN31-0AA0 3VA6440-6HN31-0AA0 3VA6440-7HN31-0AA0 3VA6440-8HN31-0AA0<br />

600 240-600 60 3VA64 3P breaker w/trip 3VA6460-5HN31-0AA0 3VA6460-6HN31-0AA0 3VA6460-7HN31-0AA0 3VA6460-8HN31-0AA0<br />

3VA64 MCS UL Type Code / MB code ==> na na CLAE / WL na<br />

600 na 60 3VA64 3P Molded Case Sw non adj. short circuit release I i ==> 3VA6460-1BB31-0AA0 na<br />

Electronic Trip Units available for 3VA61/62/63/64 series<br />

(COMPAS may require special Mod for some options)<br />

Part #<br />

Display and/or<br />

Differences Alternate Trips available I r I i I sd I g Ground Fault type Metering Included<br />

…HL31-0AA0 ETU320 LI I r I i — — na no<br />

…HM31-0AA0 ETU330 LIG I r I i — I g Adjustable Protection (b) no<br />

…JP31-0AA0 ETU550 LSI with Display only I r I i I sd — na yes - Display only<br />

…JT31-0AA0 ETU556 LSI(G) with Display only I r I i I sd I g Adjustable Alarm (a) yes - Display only<br />

…JQ31-0AA0 ETU560 LSI(G) with Display only I r I i I sd I g Adjustable Protection (b) yes - Display only<br />

…KL31-0AA0 ETU820 LI w/Display & Metering I r I i — — na yes - both<br />

…KM31-0AA0 ETU830 LIG w/Display & Metering I r I i — I g Adjustable Protection (b) yes - both<br />

…KP31-0AA0 ETU850 LSI w/Display & Metering I r I i I sd — na yes - both<br />

…KT31-0AA0 ETU856 LSI(G) w/Display & Metering I r I i I sd I g Adjustable Alarm (a) yes - both<br />

…KQ31-0AA0 ETU860 LSIG w/Display & Metering I r I i I sd I g Adjustable Protection (b) yes - both<br />

Trip Unit Feature<br />

description and notes<br />

I r<br />

Adjustable Overload<br />

Protection<br />

I i<br />

I sd<br />

I g<br />

Adjustable<br />

Instantaneous Short-<br />

Circuit Protection<br />

Adjustable Delayed<br />

Short-Circuit Protection<br />

Either (a) Adjustable<br />

Ground-Fault Alarm<br />

or (b) Adjustable<br />

Ground-Fault<br />

Protection (not both)<br />

The "L" series of UL type codes may not be available<br />

for use in all Panelboard types - check COMPAS for<br />

verification.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-57


3VA Breaker Configuration Information in Panelboards<br />

Revised on 02/29/20<br />

3VA Electronic Trip Units — 100% Rated<br />

Selection<br />

11<br />

PANELBOARDS<br />

3VA6 100% rated ETU – "Electronic Trip" versions of 3VA Breakers in Panelboards<br />

n See following pages for internal accessory pocket locations available in TMTU & ETU versions<br />

n Breakers shown do not include lugs - lugs are ordered separately as needed per application<br />

n COMPAS will allow various Lug configurations based on Panel Type and mounting location<br />

For Accessories<br />

and positions see<br />

tables on pages<br />

11-64 and 11-68<br />

Connector Kits for 3 Pole 3VA6 series Breakers – 100% rated (Requires CU Connectors)<br />

Description<br />

note: Use 3-pole for<br />

2-pole applications<br />

Connector Kits AL CU<br />

One Connector Kit<br />

required for each<br />

breaker when panel<br />

mounted.<br />

3 Pole 3VA6 series Breakers – 100% rated – without connectors<br />

Standard in COMPAS includes ETU350 LSI Trip<br />

(Ir and Ii are adjustable)<br />

ETU350 LSI<br />

included<br />

3VA61/62 not allowed 3VA9243-0JD12<br />

3VA63 not allowed 3VA9373-0JD13<br />

3VA64<br />

ETU350 LSI<br />

included<br />

ETU350 LSI<br />

included<br />

ETU350 LSI<br />

included<br />

kA ratings @ 50/60 Hz 3-pole 3-pole 3-pole 3-pole<br />

240 VAC kAIC rating ==> 100 100 200 200<br />

480Y / 277 VAC kAIC rating ==> 35 65 100 150<br />

480 VAC kAIC rating ==> 35 65 100 150<br />

600Y / 347 VAC kAIC rating ==> 18 22 35 50<br />

600 VAC kAIC rating ==> 18 22 35 50<br />

250 VDC kAIC rating ==> na na na na<br />

amps Adj. Ir code<br />

3VA61 UL Type Code / MB code ==> MDAE / W2 HDAE / W3 CDAE / W4 LDAE a / W5<br />

40 16-40 40 3VA61 3P breaker w/trip 3VA6140-5HN31-2AA0 3VA6140-6HN31-2AA0 3VA6140-7HN31-2AA0 3VA6140-8HN31-2AA0<br />

100 40-100 10 3VA61 3P breaker w/trip 3VA6110-5HN31-2AA0 3VA6110-6HN31-2AA0 3VA6110-7HN31-2AA0 3VA6110-8HN31-2AA0<br />

150 60-150 15 3VA61 3P breaker w/trip 3VA6115-5HN31-2AA0 3VA6115-6HN31-2AA0 3VA6115-7HN31-2AA0 3VA6115-8HN31-2AA0<br />

3VA62 UL Type Code / MB code ==> MFAE / WA HFAE / WB CFAE / WC LFAE a / WD<br />

100 40-100 10 3VA62 3P breaker w/trip 3VA6210-5HN31-2AA0 3VA6210-6HN31-2AA0 3VA6210-7HN31-2AA0 3VA6210-8HN31-2AA0<br />

250 100-250 25 3VA62 3P breaker w/trip 3VA6225-5HN31-2AA0 3VA6225-6HN31-2AA0 3VA6225-7HN31-2AA0 3VA6225-8HN31-2AA0<br />

3VA63 UL Type Code / MB code ==> MJAE / WE HJAE / WF CJAE / WG LJAE a / WH<br />

250 100-250 25 3VA63 3P breaker w/trip 3VA6325-5HN31-2AA0 3VA6325-6HN31-2AA0 3VA6325-7HN31-2AA0 3VA6325-8HN31-2AA0<br />

3VA64 UL Type Code / MB code ==> MLAE / WJ HLAE / WK CLAE / WL LLAE a / WM<br />

400 160-400 40 3VA64 3P breaker w/trip 3VA6440-5HN31-2AA0 3VA6440-6HN31-2AA0 3VA6440-7HN31-2AA0 3VA6440-8HN31-2AA0<br />

Electronic Trip Units available for 3VA61/62/63/64 series<br />

(COMPAS may require special Mods for some options)<br />

Part #<br />

Display and/or<br />

Differences Alternate Trips available I r I i I sd I g Ground Fault type Metering Included<br />

…HL31-0AA0 ETU320 LI I r I i — — na no<br />

…HM31-0AA0 ETU330 LIG I r I i — I g Adjustable Protection (b) no<br />

…JP31-0AA0 ETU550 LSI with Display only I r I i I sd — na yes - Display only<br />

…JT31-0AA0 ETU556 LSI(G) with Display only I r I i I sd I g Adjustable Alarm (a) yes - Display only<br />

…JQ31-0AA0 ETU560 LSI(G) with Display only I r I i I sd I g Adjustable Protection (b) yes - Display only<br />

…KL31-0AA0 ETU820 LI w/Display & Metering I r I i — — na yes - both<br />

…KM31-0AA0 ETU830 LIG w/Display & Metering I r I i — I g Adjustable Protection (b) yes - both<br />

…KP31-0AA0 ETU850 LSI w/Display & Metering I r I i I sd — na yes - both<br />

…KT31-0AA0 ETU856 LSI(G) w/Display & Metering I r I i I sd I g Adjustable Alarm (a) yes - both<br />

…KQ31-0AA0 ETU860 LSIG w/Display & Metering I r I i I sd I g Adjustable Protection (b) yes - both<br />

Trip Unit Feature<br />

description and notes<br />

I r<br />

Adjustable Overload<br />

Protection<br />

I i<br />

I sd<br />

I g<br />

Adjustable<br />

Instantaneous Short-<br />

Circuit Protection<br />

Adjustable Delayed<br />

Short-Circuit Protection<br />

Either (a) Adjustable<br />

Ground-Fault Alarm<br />

or (b) Adjustable<br />

Ground-Fault<br />

Protection (not both)<br />

The "L" series of UL type codes may not be available<br />

for use in all Panelboard types - check COMPAS for<br />

verification.<br />

11-58<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Breaker Configuration Information in Panelboards<br />

Revised on 04/30/19<br />

Communications Modules<br />

Selection<br />

3VA6 Communications modules and related accessories for field installation a<br />

n COMPAS may not allow some of these kits for selection - Special Mod may be required.<br />

n Some items may not be installed in panels and may be shipped separate from Panels even if Configured in COMPAS<br />

Description<br />

Quick<br />

reference<br />

code<br />

Voltage<br />

AC max<br />

or range<br />

Voltage<br />

DC max<br />

or range<br />

Accessory<br />

Catalog<br />

Number b<br />

Qty of<br />

slots in<br />

breaker<br />

req'd<br />

Max.<br />

Qty.<br />

per<br />

Brkr<br />

Position to install for<br />

3VA61/62 and<br />

3VA63/64 only<br />

Pocket reference # ==> 25 24 23 22 21 11 12 13 14 15<br />

Group b Left side pocket Right side pocket<br />

COM Modules and Cables<br />

Communications Module - 3VA61/62 COM060 n/a 24VDC 3VA9177-0TB10 4 1 X<br />

Communications Module - 3VA63/64 COM060 n/a 24VDC 3VA9377-0TB10 4 1 X<br />

COM060-to-T-Connector ext. cable 0.4 m COM060-to-T n/a n/a 3VA9987-0TF20 n/a n/a External<br />

COM060-to-T-Connector ext. cable 0.8 m COM060-to-T n/a n/a 3VA9987-0TF10 n/a n/a External<br />

COM060 T-Connector (spare part) T-Connector n/a n/a 3VA9987-0TG10 n/a n/a External<br />

Terminal Resistor TermRes n/a n/a 3VA9987-0TE10 n/a n/a External<br />

COM800 Breaker Data Server = max 8 COM800 n/a n/a 3VA9977-0TA10 n/a n/a P4/P5 only and SWBD<br />

COM100 Breaker Data Server = max 1 COM100 n/a n/a 3VA9977-0TA20 n/a n/a P4/P5 only and SWBD<br />

COM100-800 extension cable 0.4 m COM ext Cable n/a n/a 3VA9987-0TC10 n/a n/a P4/P5 only and SWBD<br />

COM100-800 extension cable 1 m COM ext Cable n/a n/a 3VA9987-0TC20 n/a n/a P4/P5 only and SWBD<br />

COM100-800 extension cable 2 m COM ext Cable n/a n/a 3VA9987-0TC30 n/a n/a P4/P5 only and SWBD<br />

COM100-800 extension cable 4 m COM ext Cable n/a n/a 3VA9987-0TC40 n/a n/a P4/P5 only and SWBD<br />

7KM Pac Profibus DP Expansion Module 7KMAB n/a n/a 7KM9300-0AB01-0AA0 n/a n/a P4/P5 only and SWBD<br />

7KM PAC Switched Ethernet Profinet<br />

Expansion Module<br />

7KMAE n/a n/a 7KM9300-0AE01-0AA0 n/a n/a P4/P5 only and SWBD<br />

7KM PAC RS485 Modbus RTU Exp. Module 7KMAM n/a n/a 7KM9300-0AM00-0AA0 n/a n/a P4/P5 only and SWBD<br />

DAS, Displays and Related Components<br />

DAS Module "Maintenance Mode Box" MMB300 n/a n/a 3VA9977-0UF10 n/a n/a P4/P5 only and SWBD<br />

EFB300 - External function box EFB300 n/a n/a 3VA9977-0UA10 n/a n/a P4/P5 only and SWBD<br />

Display - DSP800 DSP800 n/a n/a 3VA9977-0TD10 n/a n/a P4/P5 only and SWBD<br />

1.5m Connecting cable for MMB300/EFB300 MMB/EFB 1.5m n/a n/a 3VA9987-UB10 n/a n/a P4/P5 only and SWBD<br />

3.0m Connecting cable for MMB300/EFB300 MMB/EFB 3.0m n/a n/a 3VA9987-UB20 n/a n/a P4/P5 only and SWBD<br />

Motor Operators<br />

M0320 Motor Operator - 24-60V DC M0320 n/a 24-60V 3VA9447-0HA10 n/a 1 P4/P5 only and SWBD<br />

M0320 Motor Operator - 110-230V AC or<br />

110-250V DC<br />

EFB300 n/a n/a 3VA9977-0UA10 n/a 1 P4/P5 only and SWBD<br />

Misc. External Components and Cables<br />

Neutral Current Transformer, In = 25-150A NCT150 n/a n/a 3VA9077-0NA10 n/a n/a P4/P5 only and SWBD<br />

Neutral Current Transformer, In= 160-350A NCT350 n/a n/a 3VA9177-0NA10 n/a n/a P4/P5 only and SWBD<br />

Neutral Current Transformer, In = 400-630A NCT630 n/a n/a 3VA9377-0NA10 n/a n/a P4/P5 only and SWBD<br />

TD300 - Activation & Trip Box TD300 n/a n/a 3VA9977-0MA10 n/a n/a P4/P5 only and SWBD<br />

TD500 - Test device TD500 n/a n/a 3VA9977-0MB10 n/a n/a P4/P5 only and SWBD<br />

TD500 External Power Supply TD500EX n/a n/a 3VA9987-0MX10 n/a n/a P4/P5 only and SWBD<br />

Cable to connect to TD500 from 3VA6 TD500CBL n/a n/a 3VA9977-0MY10 n/a n/a P4/P5 only and SWBD<br />

Special Connector Lugs with Control Wire Tap<br />

#14-3/0 AL wire connector Kit c w/con-tap AL-lug 3VA51 3VA9133-0JG11 125A TMTU only Line or Load end as needed<br />

#14-2/0 CU wire connector Kit c w/con-tap CU-lug 3VA51 3VA9133-0JK11 125A TMTU only Line or Load end as needed<br />

#6-350 kcmil AL wire conn. Kit c w/con-tap AL-lug 3VA52 3VA9233-0JG12 250A TMTU only Line or Load end as needed<br />

#6-350 kcmil CU wire conn. Kit c w/con-tap CU-lug 3VA52 3VA9233-0JK12 250A TMTU only Line or Load end as needed<br />

11 PANELBOARDS<br />

#14-1/0 AL wire connector Kit c w/con-tap AL-lug 3VA61 3VA9143-0JG11 150A ETU only Line or Load end as needed<br />

#6-350 kcmil AL wire conn. Kit c w/con-tap AL-lug 3VA61/62 3VA9243-0JG12 150/250A ETU only Line or Load end as needed<br />

#14-1/0 CU wire connector Kit c w/con-tap CU-lug 3VA61 3VA9143-0JK11 150A ETU only Line or Load end as needed<br />

#6-350 kcmil CU wire conn. Kit c w/con-tap CU-lug 3VA61/62 3VA9243-0JK12 150/250A ETU only Line or Load end as needed<br />

#1-600 kcmil AL wire conn. Kit c w/con-tap AL-lug 3VA53/63 3VA9373-0JG13 400A TMTU or ETU Line or Load end as needed<br />

#1-600 kcmil CU wire conn. Kit c w/con-tap CU-lug 3VA53/63 3VA9373-0JK13 400A TMTU or ETU Line or Load end as needed<br />

2/0-600 kcmil AL 2 port conn. Kit c w/con-tap AL-2lug 3VA54/64 3VA9473-0JC23 600A TMTU or ETU Line or Load end as needed<br />

a Some accessories may be "field install only" if not available in COMPAS, or not<br />

available for use in Panelboards<br />

b Many accessories available for the 3VA5 and 3VA6 breakers may not be suitable for use<br />

in Lighting Panelboards.<br />

- COMPAS allows only options that are available for factory assembly.<br />

Some accessories listed above may not be available for all Panelboard configurations.<br />

c Lugs are NOT supplied with loose breaker as standard - must order seperately or<br />

configure in COMPAS to include lugs.<br />

- Factory assembled panels include AL lugs as standard without control wire tap,<br />

CU lugs are optional. These kits include 3 connectors and hardware.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-59


3VA Breaker Configuration Information in Panelboards<br />

Revised on 02/29/20<br />

3VA41 Breakers – 1 Pole and 1 Pole in 2-Pole Frame<br />

Selection<br />

11<br />

PANELBOARDS<br />

3VA41 1 Pole Breakers<br />

3VA41 TMTU 125A max. - breakers include AL lugs installed<br />

3VA41<br />

1-Pole Description<br />

TMTU<br />

frame<br />

1 Pole 3VA41<br />

with AL connectors included – for 14 AWG to 3/0 - CU/AL cable<br />

for CU order one 3VA9133-0JD11 connector kit<br />

Note: No accessory pockets available – see 1-pole in 2-pole frame<br />

UL Type Code ==> SEAB MEAB HEAB<br />

Panelboard MB codes ==> V1 V2 V3<br />

120 VAC kAIC rating ==> 65 85 150 a<br />

277 VAC kAIC rating ==> 25 35 65<br />

347 VAC kAIC rating ==> 14 18 25<br />

125 VDC kAIC rating b ==> 14 25 30<br />

IC family @ 277 VAC ==> 25kA 35kA 65kA<br />

FTFM Trip included ==> TM210 TM210 TM210<br />

Type<br />

kA<br />

code<br />

Type<br />

ref<br />

MB<br />

code<br />

3VA41 SEAB S EAB V1<br />

3VA41 MEAB M EAB V2<br />

3VA41 HEAB H EAB V3<br />

Catalog Number Catalog Number Catalog Number<br />

Amps Code Description<br />

1-pole 1-pole 1-pole<br />

15 95 3VA41 1P breaker w/TM210 3VA4195-4ED14-0AA0 3VA4195-5ED14-0AA0 3VA4195-6ED14-0AA0<br />

20 20 3VA41 1P breaker w/TM210 3VA4120-4ED14-0AA0 3VA4120-5ED14-0AA0 3VA4120-6ED14-0AA0<br />

25 25 3VA41 1P breaker w/TM210 3VA4125-4ED14-0AA0 3VA4125-5ED14-0AA0 3VA4125-6ED14-0AA0<br />

30 30 3VA41 1P breaker w/TM210 3VA4130-4ED14-0AA0 3VA4130-5ED14-0AA0 3VA4130-6ED14-0AA0<br />

35 35 3VA41 1P breaker w/TM210 3VA4135-4ED14-0AA0 3VA4135-5ED14-0AA0 3VA4135-6ED14-0AA0<br />

40 40 3VA41 1P breaker w/TM210 3VA4140-4ED14-0AA0 3VA4140-5ED14-0AA0 3VA4140-6ED14-0AA0<br />

45 45 3VA41 1P breaker w/TM210 3VA4145-4ED14-0AA0 3VA4145-5ED14-0AA0 3VA4145-6ED14-0AA0<br />

50 50 3VA41 1P breaker w/TM210 3VA4150-4ED14-0AA0 3VA4150-5ED14-0AA0 3VA4150-6ED14-0AA0<br />

60 60 3VA41 1P breaker w/TM210 3VA4160-4ED14-0AA0 3VA4160-5ED14-0AA0 3VA4160-6ED14-0AA0<br />

70 70 3VA41 1P breaker w/TM210 3VA4170-4ED14-0AA0 3VA4170-5ED14-0AA0 3VA4170-6ED14-0AA0<br />

80 80 3VA41 1P breaker w/TM210 3VA4180-4ED14-0AA0 3VA4180-5ED14-0AA0 3VA4180-6ED14-0AA0<br />

90 90 3VA41 1P breaker w/TM210 3VA4190-4ED14-0AA0 3VA4190-5ED14-0AA0 3VA4190-6ED14-0AA0<br />

100 10 3VA41 1P breaker w/TM210 3VA4110-4ED14-0AA0 3VA4110-5ED14-0AA0 3VA4110-6ED14-0AA0<br />

110 11 3VA41 1P breaker w/TM210 3VA4111-4ED14-0AA0 3VA4111-5ED14-0AA0 3VA4111-6ED14-0AA0<br />

125 12 3VA41 1P breaker w/TM210 3VA4112-4ED14-0AA0 3VA4112-5ED14-0AA0 3VA4112-6ED14-0AA0<br />

3VA41<br />

1-Pole in 2-Pole Description<br />

1 Pole in 2-Pole Frame 3VA41<br />

with AL connectors included for CU order one 3VA9133-0JD11 connector kit<br />

Note: Only 3 Left side Accessory pockets available<br />

Catalog Number Catalog Number Catalog Number<br />

amps code Description<br />

1-Pole in 2-Pole Frame 1-Pole in 2-Pole Frame 1-Pole in 2-Pole Frame<br />

15 95 3VA41 1P breaker w/TM210 3VA4195-4ED54-0AA0 3VA4195-5ED54-0AA0 3VA4195-6ED54-0AA0<br />

20 20 3VA41 1P breaker w/TM210 3VA4120-4ED54-0AA0 3VA4120-5ED54-0AA0 3VA4120-6ED54-0AA0<br />

25 25 3VA41 1P breaker w/TM210 3VA4125-4ED54-0AA0 3VA4125-5ED54-0AA0 3VA4125-6ED54-0AA0<br />

30 30 3VA41 1P breaker w/TM210 3VA4130-4ED54-0AA0 3VA4130-5ED54-0AA0 3VA4130-6ED54-0AA0<br />

35 35 3VA41 1P breaker w/TM210 3VA4135-4ED54-0AA0 3VA4135-5ED54-0AA0 3VA4135-6ED54-0AA0<br />

40 40 3VA41 1P breaker w/TM210 3VA4140-4ED54-0AA0 3VA4140-5ED54-0AA0 3VA4140-6ED54-0AA0<br />

45 45 3VA41 1P breaker w/TM210 3VA4145-4ED54-0AA0 3VA4145-5ED54-0AA0 3VA4145-6ED54-0AA0<br />

50 50 3VA41 1P breaker w/TM210 3VA4150-4ED54-0AA0 3VA4150-5ED54-0AA0 3VA4150-6ED54-0AA0<br />

60 60 3VA41 1P breaker w/TM210 3VA4160-4ED54-0AA0 3VA4160-5ED54-0AA0 3VA4160-6ED54-0AA0<br />

70 70 3VA41 1P breaker w/TM210 3VA4170-4ED54-0AA0 3VA4170-5ED54-0AA0 3VA4170-6ED54-0AA0<br />

80 80 3VA41 1P breaker w/TM210 3VA4180-4ED54-0AA0 3VA4180-5ED54-0AA0 3VA4180-6ED54-0AA0<br />

90 90 3VA41 1P breaker w/TM210 3VA4190-4ED54-0AA0 3VA4190-5ED54-0AA0 3VA4190-6ED54-0AA0<br />

100 10 3VA41 1P breaker w/TM210 3VA4110-4ED54-0AA0 3VA4110-5ED54-0AA0 3VA4110-6ED54-0AA0<br />

110 11 3VA41 1P breaker w/TM210 3VA4111-4ED54-0AA0 3VA4111-5ED54-0AA0 3VA4111-6ED54-0AA0<br />

125 12 3VA41 1P breaker w/TM210 3VA4112-4ED54-0AA0 3VA4112-5ED54-0AA0 3VA4112-6ED54-0AA0<br />

a Although some breakers have a kAIC rating above 100<br />

kAIC – many panels are limited to 100 kAIC or less.<br />

b DC Voltage panels are limited by various factors.<br />

These DC ratings apply to the Breaker only.<br />

11-60<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Breaker Configuration Information in Panelboards<br />

Revised on 02/29/20<br />

3VA41 Breakers – 2 Pole and 3 Pole<br />

Selection<br />

3VA41 2 and 3 Pole Breakers<br />

3VA41 TMTU 125A max. - breakers include AL lugs installed<br />

3VA41<br />

3-Pole Description<br />

TMTU<br />

frame<br />

3 Pole 3VA41<br />

with AL connectors included – for 14 AWG to 3/0 - CU/AL cable<br />

for CU order one 3VA9133-0JD11 connector kit<br />

UL Type Code ==> SEAB MEAB HEAB<br />

Panelboard MB codes ==> V1 V2 V3<br />

Ratings 3-pole | 2-pole 3-pole | 2-pole 3-pole | 2-pole<br />

240 VAC kAIC rating ==> 65 | 65 85 | 85 150 a | 150 a<br />

480Y / 277 VAC kAIC rating ==> 25 | 25 35 | 35 65 | 65<br />

480 VAC kAIC rating ==> 25 | 25 35 | 35 65 | 65<br />

600Y / 347 VAC kAIC rating ==> 14 | 14 18 | 18 25 | 25<br />

600 VAC kAIC rating ==> na | na na | na na | na<br />

250 VDC kAIC rating b ==> na | 50 na | 85 na | 100<br />

IC family @ 277 VAC ==> 25kA 35kA 65kA<br />

FTFM Trip included ==> TM210 TM210 TM210<br />

Type<br />

kA<br />

code<br />

Type<br />

ref<br />

MB<br />

code<br />

3VA41 SEAB S EAB V1<br />

3VA41 MEAB M EAB V2<br />

3VA41 HEAB H EAB V3<br />

11 PANELBOARDS<br />

Catalog Number Catalog Number Catalog Number<br />

Amps Code Description<br />

3-pole 3-pole 3-pole<br />

15 95 3VA41 3P breaker w/TM230 3VA4195-4ED34-0AA0 3VA4195-5ED34-0AA0 3VA4195-6ED34-0AA0<br />

20 20 3VA41 3P breaker w/TM230 3VA4120-4ED34-0AA0 3VA4120-5ED34-0AA0 3VA4120-6ED34-0AA0<br />

25 25 3VA41 3P breaker w/TM230 3VA4125-4ED34-0AA0 3VA4125-5ED34-0AA0 3VA4125-6ED34-0AA0<br />

30 30 3VA41 3P breaker w/TM230 3VA4130-4ED34-0AA0 3VA4130-5ED34-0AA0 3VA4130-6ED34-0AA0<br />

35 35 3VA41 3P breaker w/TM230 3VA4135-4ED34-0AA0 3VA4135-5ED34-0AA0 3VA4135-6ED34-0AA0<br />

40 40 3VA41 3P breaker w/TM230 3VA4140-4ED34-0AA0 3VA4140-5ED34-0AA0 3VA4140-6ED34-0AA0<br />

45 45 3VA41 3P breaker w/TM230 3VA4145-4ED34-0AA0 3VA4145-5ED34-0AA0 3VA4145-6ED34-0AA0<br />

50 50 3VA41 3P breaker w/TM230 3VA4150-4ED34-0AA0 3VA4150-5ED34-0AA0 3VA4150-6ED34-0AA0<br />

60 60 3VA41 3P breaker w/TM230 3VA4160-4ED34-0AA0 3VA4160-5ED34-0AA0 3VA4160-6ED34-0AA0<br />

70 70 3VA41 3P breaker w/TM230 3VA4170-4ED34-0AA0 3VA4170-5ED34-0AA0 3VA4170-6ED34-0AA0<br />

80 80 3VA41 3P breaker w/TM230 3VA4180-4ED34-0AA0 3VA4180-5ED34-0AA0 3VA4180-6ED34-0AA0<br />

90 90 3VA41 3P breaker w/TM230 3VA4190-4ED34-0AA0 3VA4190-5ED34-0AA0 3VA4190-6ED34-0AA0<br />

100 10 3VA41 3P breaker w/TM230 3VA4110-4ED34-0AA0 3VA4110-5ED34-0AA0 3VA4110-6ED34-0AA0<br />

110 11 3VA41 3P breaker w/TM230 3VA4111-4ED34-0AA0 3VA4111-5ED34-0AA0 3VA4111-6ED34-0AA0<br />

125 12 3VA41 3P breaker w/TM230 3VA4112-4ED34-0AA0 3VA4112-5ED34-0AA0 3VA4112-6ED34-0AA0<br />

Molded Case Switch<br />

100 10 3VA41 3P MCS 65 kA na na 3VA4110-1BB31-0AA0<br />

3VA41<br />

2-Pole Description<br />

2 Pole 3VA41<br />

with AL connectors included for CU order one 3VA9133-0JD11 connector kit<br />

Note: Only 3 Left side Accessory pockets available<br />

Catalog Number Catalog Number Catalog Number<br />

Amps Code Description<br />

2-pole 2-pole 2-pole<br />

15 95 3VA41 2P breaker w/TM230 3VA4195-4ED24-0AA0 3VA4195-5ED24-0AA0 3VA4195-6ED24-0AA0<br />

20 20 3VA41 2P breaker w/TM230 3VA4120-4ED24-0AA0 3VA4120-5ED24-0AA0 3VA4120-6ED24-0AA0<br />

25 25 3VA41 2P breaker w/TM230 3VA4125-4ED24-0AA0 3VA4125-5ED24-0AA0 3VA4125-6ED24-0AA0<br />

30 30 3VA41 2P breaker w/TM230 3VA4130-4ED24-0AA0 3VA4130-5ED24-0AA0 3VA4130-6ED24-0AA0<br />

35 35 3VA41 2P breaker w/TM230 3VA4135-4ED24-0AA0 3VA4135-5ED24-0AA0 3VA4135-6ED24-0AA0<br />

40 40 3VA41 2P breaker w/TM230 3VA4140-4ED24-0AA0 3VA4140-5ED24-0AA0 3VA4140-6ED24-0AA0<br />

45 45 3VA41 2P breaker w/TM230 3VA4145-4ED24-0AA0 3VA4145-5ED24-0AA0 3VA4145-6ED24-0AA0<br />

50 50 3VA41 2P breaker w/TM230 3VA4150-4ED24-0AA0 3VA4150-5ED24-0AA0 3VA4150-6ED24-0AA0<br />

60 60 3VA41 2P breaker w/TM230 3VA4160-4ED24-0AA0 3VA4160-5ED24-0AA0 3VA4160-6ED24-0AA0<br />

70 70 3VA41 2P breaker w/TM230 3VA4170-4ED24-0AA0 3VA4170-5ED24-0AA0 3VA4170-6ED24-0AA0<br />

80 80 3VA41 2P breaker w/TM230 3VA4180-4ED24-0AA0 3VA4180-5ED24-0AA0 3VA4180-6ED24-0AA0<br />

90 90 3VA41 2P breaker w/TM230 3VA4190-4ED24-0AA0 3VA4190-5ED24-0AA0 3VA4190-6ED24-0AA0<br />

100 10 3VA41 2P breaker w/TM230 3VA4110-4ED24-0AA0 3VA4110-5ED24-0AA0 3VA4110-6ED24-0AA0<br />

110 11 3VA41 2P breaker w/TM230 3VA4111-4ED24-0AA0 3VA4111-5ED24-0AA0 3VA4111-6ED24-0AA0<br />

125 12 3VA41 2P breaker w/TM230 3VA4112-4ED24-0AA0 3VA4112-5ED24-0AA0 3VA4112-6ED24-0AA0<br />

a Although some breakers have a kAIC rating above 100<br />

kAIC – many panels are limited to 100 kAIC or less.<br />

b DC Voltage panels are limited by various factors.<br />

These DC ratings apply to the Breaker only.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-61


3VA Breaker Configuration Information in Panelboards<br />

Revised on 02/29/20<br />

Internal and External Accessories for 125A 3VA Breakers<br />

Selection<br />

11<br />

PANELBOARDS<br />

Accessories for 3VA41/51 TMTU 125A max.<br />

n 6 slots max. are available - 3 on each side of trip handle.\<br />

n COMPAS will allow only modules that will be allowed in panel being configured.<br />

n Note: 3VA41/51 2-pole and "1-pole in 2-pole frame" have only 3 Left side<br />

Accessory pockets available.<br />

Accessories<br />

Internal Accessories<br />

Left side only<br />

Only one per breaker allowed<br />

Description<br />

Quick<br />

reference<br />

code<br />

Voltage<br />

AC max<br />

or range<br />

Voltage<br />

DC max<br />

or range<br />

Accessory<br />

Catalog<br />

Number b<br />

Qty of<br />

slots in<br />

breaker<br />

req'd<br />

Max.<br />

Qty.<br />

per<br />

Brkr<br />

Position<br />

to install<br />

for 3VA41/51 only<br />

Left side Right side<br />

Pocket reference # ==> 23 22 21 11 12 13<br />

Shunt trip left -10 STL-10 n/a 12 3VA9978-0BL10 3 1 X<br />

Shunt trip left -20 STL-20 380...600 n/a 3VA9978-0BL20 3 1 X<br />

Shunt trip left -30 STL-30 24 24…30 3VA9978-0BL30 3 1 X<br />

Shunt trip left -31 STL-31 48…60 n/a 3VA9978-0BL31 3 1 X<br />

Shunt trip left -32 STL-32 110…127 110…127 3VA9978-0BL32 3 1 X<br />

Shunt trip left -33 STL-33 208…277 220…250 3VA9978-0BL33 3 1 X<br />

Shunt trip flexible -20 STF-20 24 n/a 3VA9978-0BA20 3 1 X<br />

Shunt trip flexible -21 STF-21 48…60 n/a 3VA9978-0BA21 3 1 X<br />

Shunt trip flexible -22 STF-22 110…127 n/a 3VA9978-0BA22 3 1 X<br />

Shunt trip flexible -23 STF-23 208…277 n/a 3VA9978-0BA23 3 1 X<br />

Shunt trip flexible -24 STF-24 380…500 n/a 3VA9978-0BA24 3 1 X<br />

Shunt trip flexible -25 STF-25 600 n/a 3VA9978-0BA25 3 1 X<br />

Undervoltage release -10 UVR-10 n/a 12 3VA9978-0BB10 3 1 X<br />

Undervoltage release -11 UVR-11 n/a 24 3VA9978-0BB11 3 1 X<br />

Undervoltage release -12 UVR-12 n/a 48 3VA9978-0BB12 3 1 X<br />

Undervoltage release -14 UVR-14 n/a 125…127 3VA9978-0BB14 3 1 X<br />

Undervoltage release -16 UVR-16 n/a 250 3VA9978-0BB16 3 1 X<br />

Undervoltage release -20 UVR-20 24 n/a 3VA9978-0BB20 3 1 X<br />

Undervoltage release -24 UVR-24 120…127 n/a 3VA9978-0BB24 3 1 X<br />

Undervoltage release -25 UVR-25 208…230 n/a 3VA9978-0BB25 3 1 X<br />

Undervoltage release -27 UVR-27 440…480 n/a 3VA9978-0BB27 3 1 X<br />

Universal release UNI-11 n/a 12vdc 3VA9978-0BD11 3 1 X<br />

Universal release UNI-12 n/a 24vdc 3VA9978-0BD12 3 1 X<br />

Universal release UNI-13 n/a 48vdc 3VA9978-0BD13 3 1 X<br />

Internal Accessories<br />

Right side or left<br />

side options<br />

External b<br />

Accessories<br />

and field kits<br />

Auxiliary switch - standard AUX_HQ 240VAC n/a 3VA9978-0AA12 1 6 X X X X X X<br />

Leading Chg-over SW - standard LCS_HQ 240VAC n/a 3VA9978-0AA22 1 1 X<br />

Trip alarm (bell alarm) - standard TAS_HQ 240VAC 250VDC 3VA9978-0AB12 1 4 X X X X<br />

Auxiliary switch - High capacity a AUX_HP 600VAC n/a 3VA9978-0AA11 2 2 X X<br />

X<br />

X<br />

Leading Chg-over SW - High Cap a LCS_HP 600VAC 250VDC 3VA9978-0AA21 1 1 X<br />

Trip alarm (bell alarm) - High Cap a TAS_HP 600VAC 250VDC 3VA9978-0AB11 2 2 X X<br />

Auxiliary switch - electronic d AUX_HQ_el 24VAC 24VDC 3VA9978-0AA13 1 6 X X X X X X<br />

Leading Chg-over SW - electronic d LCS_HQ_el 24VAC n/a 3VA9978-0AA23 1 1 X<br />

Trip alarm (bell alarm) - electronic d TAS_HQ_el 24VAC 24VDC 3VA9978-0AB13 1 4 X X X X<br />

#14-3/0 AL wire connector Kit c AL-lug n/a n/a 3VA9133-0JB11 n/a n/a Included w/ 3VA41 only<br />

#14-2/0 CU wire connector Kit c CU-lug n/a n/a 3VA9133-0JD11 n/a n/a Load end as required<br />

Compression Lugs<br />

(future offering - details tbd)<br />

tbd n/a n/a tbd n/a n/a availability and<br />

usage locations tbd<br />

3VA41 only Padlock Device tbd n/a n/a 3VA9038-0LB11 n/a n/a for 1p, 2p or 3p<br />

3VA41 2" Handle tie Device tbd n/a n/a 3VA9032-0LB20 n/a n/a 2" wide for 1p only<br />

3VA41 3" Handle tie Device tbd n/a n/a 3VA9033-0LB20 n/a n/a 3" wide for 1p only<br />

a High capacity/power (HP) max. Amps load capacity is higher than standed module<br />

(.55A up to 6.0A) depends on Voltage and AC/DC requirements - see SpeedFax section<br />

7 or 3VA documentation for more information.<br />

b Many accessories available for the 3VA4, 3VA5 and 3VA6 breakers may not be suitable<br />

for use in Lighting Panelboards.<br />

– COMPAS allows options that are available. All accessories listed above can be used<br />

with Panelboards in general, but there will be exceptions.<br />

c Lugs are NOT supplied with loose breaker – must order separately or configured in<br />

COMPAS to include lugs. 3VA41 is an exception – AL connectors are included as standard<br />

– Factory assembled panels include AL lugs as standard, CU lugs are optional. These<br />

kits include 3 connectors and hardware<br />

d Special electronically-compatible (el) variants are available for applications that require<br />

the auxiliary switch signals to be linked to low voltage systems.<br />

– May need special Mod in COMPAS.<br />

11-62<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Breaker Configuration Information in Panelboards<br />

Revised on 04/30/19<br />

3VA52 Breakers – 2 Pole and 3 Pole<br />

Selection<br />

3VA52 2 and 3 Pole Breakers<br />

3VA52 TMTU 250A max.<br />

n Part numbers shown are without Lugs.<br />

n Standard Lug kits used in Panelboards are shown in tables below.<br />

TMTU<br />

frame<br />

Type<br />

kA<br />

code<br />

Type<br />

ref<br />

MB<br />

code<br />

3VA52 MFAS M FAS VA<br />

3VA52 HFAS H FAS VB<br />

3VA52 CFAS C FAS VC<br />

11 PANELBOARDS<br />

3VA52<br />

3-Pole Description<br />

3 Pole 3VA52 without connectors<br />

The default for Panelboard in COMPAS will be AL 1-conductor connectors:<br />

for AL order one 3VA9233-0JB12 (accepts (1) #6 AWG-350kcmil AL/CU conductor)<br />

for CU order one 3VA9233-0JD12 (accepts (1) #6 AWG-350kcmil CU only conductor)<br />

UL Type Code ==> MFAS HFAS CFAS<br />

Panelboard MB codes ==> VA VB VC<br />

Ratings 3-pole | 2-pole 3-pole | 2-pole 3-pole | 2-pole<br />

240 VAC kAIC rating ==> 85 | 85 100 | 100 200 a | 200 a<br />

480Y / 277 VAC kAIC rating ==> 35 | 35 65 | 65 100 | 100<br />

480 VAC kAIC rating ==> 35 | 35 65 | 65 100 | 100<br />

600Y / 347 VAC kAIC rating ==> 18 | 18 25 | 25 35 | 35<br />

600 VAC kAIC rating ==> 18 | 18 25 | 25 35 | 35<br />

250 VDC kAIC rating ==> na | 50 na | 85 na | 100<br />

IC family @ 480 VAC ==> 35kA 65kA 100kA<br />

FTAM Trip included ==> TM230 TM230 TM230<br />

Catalog Number Catalog Number Catalog Number<br />

Amps Code Description<br />

3-pole 3-pole 3-pole<br />

100 10 3VA52 3P breaker w/TM230 3VA5210-5EC31-0AA0 3VA5210-6EC31-0AA0 3VA5210-7EC31-0AA0<br />

110 11 3VA52 3P breaker w/TM230 3VA5211-5EC31-0AA0 3VA5211-6EC31-0AA0 3VA5211-7EC31-0AA0<br />

125 12 3VA52 3P breaker w/TM230 3VA5212-5EC31-0AA0 3VA5212-6EC31-0AA0 3VA5212-7EC31-0AA0<br />

150 15 3VA52 3P breaker w/TM230 3VA5215-5EC31-0AA0 3VA5215-6EC31-0AA0 3VA5215-7EC31-0AA0<br />

175 17 3VA52 3P breaker w/TM230 3VA5217-5EC31-0AA0 3VA5217-6EC31-0AA0 3VA5217-7EC31-0AA0<br />

200 20 3VA52 3P breaker w/TM230 3VA5220-5EC31-0AA0 3VA5220-6EC31-0AA0 3VA5220-7EC31-0AA0<br />

225 22 3VA52 3P breaker w/TM230 3VA5222-5EC31-0AA0 3VA5222-6EC31-0AA0 3VA5222-7EC31-0AA0<br />

250 25 3VA52 3P breaker w/TM230 3VA5225-5EC31-0AA0 3VA5225-6EC31-0AA0 3VA5225-7EC31-0AA0<br />

Molded Case Switch HFAS CFAS<br />

100 10 3VA52 3P MCS 100kA na na 3VA5210-1BB31-0AA0<br />

150 15 3VA52 3P MCS 65kA/100kA na 3VA5215-0BB31-0AA0 3VA5215-1BB31-0AA0<br />

250 25 3VA52 3P MCS 65kA/100kA na 3VA5225-0BB31-0AA0 3VA5225-1BB31-0AA0<br />

3VA52<br />

2-Pole Description<br />

2 Pole 3VA52 (in 3-Pole frame) without connectors<br />

The default for Panelboard in COMPAS will be AL 1-conductor connectors:<br />

for AL order one 3VA9233-0JB12 (accepts (1) #6 AWG-350kcmil AL/CU conductor)<br />

for CU order one 3VA9233-0JD12 (accepts (1) #6 AWG-350kcmil CU only conductor)<br />

Catalog Number Catalog Number Catalog Number<br />

Amps Code Description<br />

2-pole 2-pole 2-pole<br />

100 10 3VA52 2P breaker w/TM230 3VA5210-5EC61-0AA0 3VA5210-6EC61-0AA0 3VA5210-7EC61-0AA0<br />

110 11 3VA52 2P breaker w/TM230 3VA5211-5EC61-0AA0 3VA5211-6EC61-0AA0 3VA5211-7EC61-0AA0<br />

125 12 3VA52 2P breaker w/TM230 3VA5212-5EC61-0AA0 3VA5212-6EC61-0AA0 3VA5212-7EC61-0AA0<br />

150 15 3VA52 2P breaker w/TM230 3VA5215-5EC61-0AA0 3VA5215-6EC61-0AA0 3VA5215-7EC61-0AA0<br />

175 17 3VA52 2P breaker w/TM230 3VA5217-5EC61-0AA0 3VA5217-6EC61-0AA0 3VA5217-7EC61-0AA0<br />

200 20 3VA52 2P breaker w/TM230 3VA5220-5EC61-0AA0 3VA5220-6EC61-0AA0 3VA5220-7EC61-0AA0<br />

225 22 3VA52 2P breaker w/TM230 3VA5222-5EC61-0AA0 3VA5222-6EC61-0AA0 3VA5222-7EC61-0AA0<br />

250 25 3VA52 2P breaker w/TM230 3VA5225-5EC61-0AA0 3VA5225-6EC61-0AA0 3VA5225-7EC61-0AA0<br />

Molded Case Switch HFAS CFAS<br />

100 10 3VA52 2P MCS 100kA na na 3VA5210-1BB61-0AA0<br />

150 15 3VA52 2P MCS 65kA/100kA na 3VA5215-0BB61-0AA0 3VA5215-1BB61-0AA0<br />

250 25 3VA52 2P MCS 65kA/100kA na 3VA5225-0BB61-0AA0 3VA5225-1BB61-0AA0<br />

a Although some breakers have a kAIC rating above 100<br />

kAIC – many panels are limited to 100 kAIC or less.<br />

b DC Voltage panels are limited by various factors.<br />

These DC ratings apply to the Breaker only.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-63


3VA Breaker Configuration Information in Panelboards<br />

Revised on 04/30/19<br />

Internal and External Accessories for 150-250A 3VA Breakers<br />

Selection<br />

11<br />

PANELBOARDS<br />

Accessories for 3VA52, 3VA61 and 3VA62 breakers<br />

n 3VA52 TMTU 250A max. and 3VA61 ETU 150A max. and 3VA62 ETU 250A max.<br />

n 6 - 8 slots max. are available – 4 on each side of trip handle.<br />

n COMPAS will allow only modules that will be allowed in panel being configured.<br />

Description<br />

Accessories<br />

Internal Accessories<br />

Left side only<br />

Only one per breaker allowed<br />

Quick<br />

reference<br />

code<br />

Voltage<br />

AC max<br />

or range<br />

Voltage<br />

DC max<br />

or range<br />

Accessory<br />

Catalog<br />

Number b<br />

Qty of<br />

slots in<br />

breaker<br />

req'd<br />

Max.<br />

Qty.<br />

per<br />

Brkr<br />

Position<br />

to install<br />

for 3VA52/61/62 only<br />

Left side pocket Left side pocket<br />

Pocket reference # ==> 24 23 22 21 11 12 13 14<br />

Shunt trip left -10 STL-10 n/a 12 3VA9978-0BL10 3 1 X<br />

Shunt trip left -20 STL-20 380...600 n/a 3VA9978-0BL20 3 1 X<br />

Shunt trip left -30 STL-30 24 24…30 3VA9978-0BL30 3 1 X<br />

Shunt trip left -31 STL-31 48…60 n/a 3VA9978-0BL31 3 1 X<br />

Shunt trip left -32 STL-32 110…127 110…127 3VA9978-0BL32 3 1 X<br />

Shunt trip left -33 STL-33 208…277 220…250 3VA9978-0BL33 3 1 X<br />

Shunt trip flexible -20 STF-20 24 n/a 3VA9978-0BA20 3 1 X<br />

Shunt trip flexible -21 STF-21 48…60 n/a 3VA9978-0BA21 3 1 X<br />

Shunt trip flexible -22 STF-22 110…127 n/a 3VA9978-0BA22 3 1 X<br />

Shunt trip flexible -23 STF-23 208…277 n/a 3VA9978-0BA23 3 1 X<br />

Shunt trip flexible -24 STF-24 380…500 n/a 3VA9978-0BA24 3 1 X<br />

Shunt trip flexible -25 STF-25 600 n/a 3VA9978-0BA25 3 1 X<br />

Right side<br />

opt. 3VA6<br />

only<br />

Undervoltage release -10 UVR-10 n/a 12 3VA9978-0BB10 3 1 X<br />

Undervoltage release -11 UVR-11 n/a 24 3VA9978-0BB11 3 1 X<br />

Undervoltage release -12 UVR-12 n/a 48 3VA9978-0BB12 3 1 X<br />

Undervoltage release -14 UVR-14 n/a 125…127 3VA9978-0BB14 3 1 X<br />

Undervoltage release -16 UVR-16 n/a 250 3VA9978-0BB16 3 1 X<br />

Undervoltage release -20 UVR-20 24 n/a 3VA9978-0BB20 3 1 X<br />

Undervoltage release -24 UVR-24 120…127 n/a 3VA9978-0BB24 3 1 X<br />

Undervoltage release -25 UVR-25 208…230 n/a 3VA9978-0BB25 3 1 X<br />

Undervoltage release -27 UVR-27 440…480 n/a 3VA9978-0BB27 3 1 X<br />

Universal release UNI-11 n/a 12vdc 3VA9978-0BD11 3 1 X<br />

Universal release UNI-12 n/a 24vdc 3VA9978-0BD12 3 1 X<br />

Universal release UNI-13 n/a 48vdc 3VA9978-0BD13 3 1 X<br />

Internal Accessories<br />

Right or left side options<br />

3VA52, and 3VA61, 3VA62 (ETU)<br />

Auxiliary switch - standard AUX_HQ 240VAC n/a 3VA9978-0AA12 1 6 X X X X X X X X<br />

Leading Chg-over SW - standard LCS_HQ 240VAC n/a 3VA9978-0AA22 1 1 X<br />

Trip alarm (bell alarm) - standard TAS_HQ 240VAC 250VDC 3VA9978-0AB12 1 4 X X X X<br />

Electrical Alarm Switch std. (ETU 0nly) EAS_HQ 240VAC 250VDC 3VA9978-0AB22 1 1 X<br />

Auxiliary switch - high capacity a AUX_HP 600VAC n/a 3VA9978-0AA11 2 2<br />

X X X X<br />

X<br />

X<br />

Leading Chg-over SW - High Cap a LCS_HP 600VAC 250VDC 3VA9978-0AA21 1 1 X<br />

Trip alarm (bell alarm) - High Cap a TAS_HP 600VAC 250VDC 3VA9978-0AB11 2 2 X X<br />

Auxiliary switch - electronic d AUX_HQ_el 24VAC 24VDC 3VA9978-0AA13 1 6 X X X X X X X X<br />

Leading Chg-over SW - electronic d LCS_HQ_el 24VAC n/a 3VA9978-0AA23 1 1 X<br />

Trip alarm (bell alarm) - electronic d TAS_HQ_el 24VAC 24VDC 3VA9978-0AB13 1 4 X X X X<br />

Electrical Alarm Switch electronic d<br />

(ETU 0nly)<br />

EAS_HQ_el 24VAC 24VDC 3VA9978-0AB23 1 1 X<br />

Ronis adapter FOR 3VA63/64 Ronis Adapter n/a n/a 3VA9347-0LF10 4 1 X<br />

Cylinder Lock (type Ronis) Key 1 Ronis Key 1 n/a n/a 3VA9980-0VL10<br />

one one<br />

Cylinder Lock (type Ronis) Key 2 Ronis Key 2 n/a n/a 3VA9980-0VL20<br />

installs in<br />

per per<br />

adapter<br />

Cylinder Lock (type Ronis) Key 3 Ronis Key 3 n/a n/a 3VA9980-0VL30 adapter<br />

adapter<br />

above<br />

Cylinder Lock (type Ronis) Key 4 Ronis Key 4 n/a n/a 3VA9980-0VL40<br />

a High capacity/power (HP) max. Amps load capacity is higher than standed module<br />

(.55A up to 6.0A) depends on Voltage and AC/DC requirements - see SpeedFax section<br />

7 or 3VA documentation for more information.<br />

b Many accessories available for the 3VA5 and 3VA6 breakers may not be suitable for use<br />

in Lighting Panelboards.<br />

– COMPAS allows options that are available. All accessories listed above can be used<br />

with Panelboards in general, but there will be exceptions."<br />

c Lugs are NOT supplied with loose breaker as standard - must order separately or configure<br />

in COMPAS to include lugs.<br />

– Factory assembled panels include AL lugs as standard, CU lugs are optional. These<br />

kits include 3 connectors and hardware.<br />

d Special electronically-compatible (el) variants are available for applications that require<br />

the auxiliary switch signals to be linked to low voltage systems.<br />

– May need special Mod in COMPAS.<br />

11-64<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Breaker Configuration Information in Panelboards<br />

Revised on 02/29/20<br />

Internal and External Accessories for 150-250A 3VA Breakers<br />

Selection<br />

Description<br />

Accessories (continued)<br />

Quick<br />

reference<br />

code<br />

Voltage<br />

AC max<br />

or range<br />

Voltage<br />

DC max<br />

or range<br />

Accessory<br />

Catalog<br />

Number b<br />

Qty of<br />

slots in<br />

breaker<br />

req'd<br />

Max.<br />

Qty.<br />

per<br />

Brkr<br />

Position<br />

to install<br />

for 3VA52/61/62 only<br />

Left side pkt Left side pkt<br />

Pocket reference # ==> 24 23 22 21 11 12 13 14<br />

11 PANELBOARDS<br />

Internal Accessories<br />

3VA61/62 (ETU) only<br />

Communications Module - 3VA61/62 COM060 n/a 24VDC 3VA9177-0TB10 4 1 X<br />

COM060-to-T-Connector<br />

ext. cable 0.4 m<br />

COM060-to-T-Connector<br />

ext. cable 0.8 m<br />

COM060-to-T n/a n/a 3VA9987-0TF20 n/a n/a<br />

COM060-to-T n/a n/a 3VA9987-0TF10 n/a n/a<br />

COM060 T-Connector (spare part) T-Connector n/a n/a 3VA9987-0TG10 n/a n/a<br />

External b Accessories<br />

and Field Kits<br />

#6-350 kcmil AL wire connector Kit c AL-lug n/a n/a 3VA9233-0JB12 TMTU only 3VA52 Load end as required<br />

#6-350 kcmil CU wire connector Kit c CU-lug n/a n/a 3VA9233-0JD12 TMTU only 3VA52 Load end as required<br />

#14-1/0 AL wire connector Kit c AL-lug n/a n/a 3VA9143-0JB11 ETU only 3VA61/62 Load end as required<br />

#6-350 kcmil AL wire connector Kit c AL-lug n/a n/a 3VA9243-0JB12 ETU only 3VA61/62 Load end as required<br />

#14-1/0 CU wire connector Kit c CU-lug n/a n/a 3VA9143-0JD11 ETU only 3VA61/62 Load end as required<br />

#6-350 kcmil CU wire connector Kit c CU-lug n/a n/a 3VA9243-0JD12 ETU only 3VA61/62 Load end as required<br />

Compression Lugs<br />

(future offering - details tbd)<br />

tbd n/a n/a tbd n/a n/a<br />

availability and<br />

usage locations tbd<br />

3VA52/61/62 PadLock Device tbd n/a n/a 3VA9138-0LB11 n/a n/a<br />

M0320 Motor Operator<br />

- 24-60V DC<br />

M0320 Motor Operator<br />

- 110-230V AC or 110-250V DC<br />

M0320 n/a 24-60V 3VA9277-0HA10 n/a 1 P4/P5 and SWBD only<br />

M0320<br />

110-<br />

230V<br />

110-<br />

250V<br />

3VA9277-0HA20 n/a 1 P4/P5 and SWBD only<br />

COM100 and COM800 modules and cables can be found on Communications Tables with ETU Breakers earlier in this section.<br />

a High capacity/power (HP) max. Amps load capacity is higher than standed module<br />

(.55A up to 6.0A) depends on Voltage and AC/DC requirements - see SpeedFax section<br />

7 or 3VA documentation for more information.<br />

b Many accessories available for the 3VA5 and 3VA6 breakers may not be suitable for use<br />

in Lighting Panelboards.<br />

– COMPAS allows options that are available. All accessories listed above can be used<br />

with Panelboards in general, but there will be exceptions."<br />

c Lugs are NOT supplied with loose breaker as standard - must order separately or configure<br />

in COMPAS to include lugs.<br />

– Factory assembled panels include AL lugs as standard, CU lugs are optional. These<br />

kits include 3 connectors and hardware.<br />

d Special electronically-compatible (el) variants are available for applications that require<br />

the auxiliary switch signals to be linked to low voltage systems.<br />

– May need special Mod in COMPAS.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-65


3VA Breaker Configuration Information in Panelboards<br />

Revised on 02/29/20<br />

3VA53 Breakers – 2 Pole and 3 Pole<br />

Selection<br />

11<br />

PANELBOARDS<br />

3VA53 Breakers<br />

3VA53 TMTU 400A max.<br />

n Part numbers shown are without Lugs.<br />

n Standard Lug kits used in Panelboards are shown in tables below.<br />

TMTU<br />

frame<br />

Type<br />

kA<br />

code<br />

Type<br />

ref<br />

MB<br />

code<br />

3VA53 MJAS M JAS VE<br />

3VA53 HJAS H JAS VF<br />

3VA53 CJAS C JAS VG<br />

3VA53<br />

3-Pole Description<br />

3 Pole 3VA53 without connectors<br />

The default for Panelboard in COMPAS will be AL 2-conductor connectors:<br />

for AL order one 3VA9473-0JJ23 (accepts (2) 2/0-600kcmil AL/CU conductors)<br />

for CU order one 3VA9473-0JE23 (accepts (2) 2/0-600kcmil CU only conductors)<br />

Alternate single conductor lugs are available:<br />

for AL order one 3VA9473-0JB13 (accepts (1) #1 AWG-600kcmil AL/CU conductors)<br />

for CU order one 3VA9473-0JD13 (accepts (1) #1 AWG-600kcmil CU only conductors)<br />

UL Type Code ==> MJAS HJAS CJAS<br />

Panelboard MB codes ==> VE VF VG<br />

Ratings 3-pole | 2-pole 3-pole | 2-pole 3-pole | 2-pole<br />

240 VAC kAIC rating ==> 85 | 85 100 | 100 200 a | 200 a<br />

480Y / 277 VAC kAIC rating ==> 35 | 35 65 | 65 100 | 100<br />

480 VAC kAIC rating ==> 35 | 35 65 | 65 100 | 100<br />

600Y / 347 VAC kAIC rating ==> 18 | 18 25 | 25 35 | 35<br />

600 VAC kAIC rating ==> 18 | 18 25 | 25 35 | 35<br />

250 VDC kAIC rating b ==> na | 50 na | 85 na | 100<br />

IC family @ 480 VAC ==> 35kA 65kA 100kA<br />

FTAM Trip included ==> TM230 TM230 TM230<br />

Catalog Number Catalog Number Catalog Number<br />

Amps Code Description<br />

3-pole 3-pole 3-pole<br />

200 20 3VA53 3P breaker w/TM230 3VA5320-5EC31-0AA0 3VA5320-6EC31-0AA0 3VA5320-7EC31-0AA0<br />

225 22 3VA53 3P breaker w/TM230 3VA5322-5EC31-0AA0 3VA5322-6EC31-0AA0 3VA5322-7EC31-0AA0<br />

250 25 3VA53 3P breaker w/TM230 3VA5325-5EC31-0AA0 3VA5325-6EC31-0AA0 3VA5325-7EC31-0AA0<br />

300 30 3VA53 3P breaker w/TM230 3VA5330-5EC31-0AA0 3VA5330-6EC31-0AA0 3VA5330-7EC31-0AA0<br />

350 35 3VA53 3P breaker w/TM230 3VA5335-5EC31-0AA0 3VA5335-6EC31-0AA0 3VA5335-7EC31-0AA0<br />

400 40 3VA53 3P breaker w/TM230 3VA5340-5EC31-0AA0 3VA5340-6EC31-0AA0 3VA5340-7EC31-0AA0<br />

3VA53<br />

2-Pole Description<br />

2 Pole 3VA53 (in 3-Pole frame) without connectors<br />

The default for Panelboard in COMPAS will be AL 2-conductor connectors:<br />

for AL order one 3VA9473-0JJ23 (accepts (2) 2/0-600kcmil AL/CU conductors)<br />

for CU order one 3VA9473-0JE23 (accepts (2) 2/0-600kcmil CU only conductors)<br />

Alternate single conductor lugs are available:<br />

for AL order one 3VA9473-0JB13 (accepts (1) #1 AWG-600kcmil AL/CU conductors)<br />

for CU order one 3VA9473-0JD13 (accepts (1) #1 AWG-600kcmil CU only conductors)<br />

Catalog Number Catalog Number Catalog Number<br />

Amps Code Description<br />

2-pole 2-pole 2-pole<br />

200 20 3VA53 2P breaker w/TM230 3VA5320-5EC61-0AA0 3VA5320-6EC61-0AA0 3VA5320-7EC61-0AA0<br />

225 22 3VA53 2P breaker w/TM230 3VA5322-5EC61-0AA0 3VA5322-6EC61-0AA0 3VA5322-7EC61-0AA0<br />

250 25 3VA53 2P breaker w/TM230 3VA5325-5EC61-0AA0 3VA5325-6EC61-0AA0 3VA5325-7EC61-0AA0<br />

300 30 3VA53 2P breaker w/TM230 3VA5330-5EC61-0AA0 3VA5330-6EC61-0AA0 3VA5330-7EC61-0AA0<br />

350 35 3VA53 2P breaker w/TM230 3VA5335-5EC61-0AA0 3VA5335-6EC61-0AA0 3VA5335-7EC61-0AA0<br />

400 40 3VA53 2P breaker w/TM230 3VA5340-5EC61-0AA0 3VA5340-6EC61-0AA0 3VA5340-7EC61-0AA0<br />

a Although some breakers have a kAIC rating above 100<br />

kAIC – many panels are limited to 100 kAIC or less.<br />

b DC Voltage panels are limited by various factors.<br />

These DC ratings apply to the Breaker only.<br />

11-66<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Breaker Configuration Information in Panelboards<br />

Revised on 02/29/20<br />

3VA54 Breakers – 2 Pole and 3 Pole<br />

Selection<br />

3VA54 Breakers<br />

3VA54 TMTU 600A max.<br />

n Part numbers shown are without Lugs.<br />

n Standard Lug kits used in Panelboards are shown in tables below.<br />

TMTU<br />

frame<br />

Type<br />

kA<br />

code<br />

Type<br />

ref<br />

MB<br />

code<br />

3VA54 MLAS M LAS VJ<br />

3VA54 HLAS H LAS VK<br />

3VA54 CLAS C LAS VL<br />

11 PANELBOARDS<br />

3VA54<br />

3-Pole Description<br />

3 Pole 3VA54 without connectors<br />

The default for Panelboard in COMPAS will be AL 2-conductor connectors:<br />

for AL order one 3VA9473-0JJ23 (accepts (2) 2/0-600kcmil AL/CU conductors)<br />

for CU order one 3VA9473-0JE23 (accepts (2) 2/0-600kcmil CU only conductors)<br />

Alternate single conductor lugs are available:<br />

for AL order one 3VA9473-0JB13 (accepts (1) #1 AWG-600kcmil AL/CU conductors)<br />

for CU order one 3VA9473-0JD13 (accepts (1) #1 AWG-600kcmil CU only conductors)<br />

UL Type Code ==> MLAS HLAS CLAS<br />

Panelboard MB codes ==> VJ VK VL<br />

Ratings 3-pole | 2-pole 3-pole | 2-pole 3-pole | 2-pole<br />

240 VAC kAIC rating ==> 85 | 85 100 | 100 200 a | 200 a<br />

480Y / 277 VAC kAIC rating ==> 35 | 35 65 | 65 100 | 100<br />

480 VAC kAIC rating ==> 35 | 35 65 | 65 100 | 100<br />

600Y / 347 VAC kAIC rating ==> 18 | 18 25 | 25 35 | 35<br />

600 VAC kAIC rating ==> 18 | 18 25 | 25 35 | 35<br />

250 VDC kAIC rating b ==> na | 50 na | 85 na | 100<br />

IC family @ 480 VAC ==> 35kA 65kA 100kA<br />

FTAM Trip included ==> TM230 TM230 TM230<br />

Catalog Number Catalog Number Catalog Number<br />

Amps Code Description<br />

3-pole 3-pole 3-pole<br />

450 45 3VA54 3P breaker w/TM230 3VA5445-5EC31-0AA0 3VA5445-6EC31-0AA0 3VA5445-7EC31-0AA0<br />

500 50 3VA54 3P breaker w/TM230 3VA5450-5EC31-0AA0 3VA5450-6EC31-0AA0 3VA5450-7EC31-0AA0<br />

600 60 3VA54 3P breaker w/TM230 3VA5460-5EC31-0AA0 3VA5460-6EC31-0AA0 3VA5460-7EC31-0AA0<br />

3VA54<br />

2-Pole Description<br />

2 Pole 3VA54 (in 3-Pole frame) without connectors<br />

The default for Panelboard in COMPAS will be AL 2-conductor connectors:<br />

for AL order one 3VA9473-0JJ23 (accepts (2) 2/0-600kcmil AL/CU conductors)<br />

for CU order one 3VA9473-0JE23 (accepts (2) 2/0-600kcmil CU only conductors)<br />

Alternate single conductor lugs are available:<br />

for AL order one 3VA9473-0JB13 (accepts (1) #1 AWG-600kcmil AL/CU conductors)<br />

for CU order one 3VA9473-0JD13 (accepts (1) #1 AWG-600kcmil CU only conductors)<br />

Catalog Number Catalog Number Catalog Number<br />

Amps Code Description<br />

2-pole 2-pole 2-pole<br />

450 45 3VA54 2P breaker w/TM230 3VA5445-5EC61-0AA0 3VA5445-6EC61-0AA0 3VA5445-7EC61-0AA0<br />

500 50 3VA54 2P breaker w/TM230 3VA5450-5EC61-0AA0 3VA5450-6EC61-0AA0 3VA5450-7EC61-0AA0<br />

600 60 3VA54 2P breaker w/TM230 3VA5460-5EC61-0AA0 3VA5460-6EC61-0AA0 3VA5460-7EC61-0AA0<br />

a Although some breakers have a kAIC rating above 100<br />

kAIC – many panels are limited to 100 kAIC or less.<br />

b DC Voltage panels are limited by various factors.<br />

These DC ratings apply to the Breaker only.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-67


3VA Breaker Configuration Information in Panelboards<br />

Revised on 04/30/19<br />

Internal and External Accessories for 400-600A 3VA Breakers<br />

Selection<br />

11<br />

PANELBOARDS<br />

Accessories for 3VA53, 3VA63, 3VA54 and 3VA64 breakers<br />

n 3VA53 TMTU 400A max. and 3VA63 ETU 400A max.3VA54 TMTU 600A max. and 3VA64 ETU 600A max.<br />

n 10 slots max. are available - 5 on each side of trip handle.<br />

n COMPAS will allow only modules that will be allowed in panel being configured.<br />

Description<br />

Accessories<br />

Internal Accessories<br />

Left side preferred<br />

Only one per breaker allowed<br />

Quick<br />

reference<br />

code<br />

Voltage<br />

AC max<br />

or range<br />

Voltage<br />

DC max<br />

or range<br />

Accessory<br />

Catalog<br />

Number b<br />

Qty of<br />

slots in<br />

breaker<br />

req'd<br />

Max.<br />

Qty.<br />

per<br />

Brkr<br />

Position to install for<br />

3VA53/63 and<br />

3VA54/64 only<br />

Left side pocket Right side pocket<br />

Pocket reference # ==> 25 24 23 22 21 11 12 13 14 15<br />

Shunt trip left -10 STL-10 n/a 12 3VA9978-0BL10 3 1 X<br />

Shunt trip left -20 STL-20 380...600 n/a 3VA9978-0BL20 3 1 X<br />

Shunt trip left -30 STL-30 24 24…30 3VA9978-0BL30 3 1 X<br />

Shunt trip left -31 STL-31 48…60 n/a 3VA9978-0BL31 3 1 X<br />

Shunt trip left -32 STL-32 110…127 110…127 3VA9978-0BL32 3 1 X<br />

Shunt trip left -33 STL-33 208…277 220…250 3VA9978-0BL33 3 1 X<br />

Shunt trip flexible -20 STF-20 24 n/a 3VA9978-0BA20 3 1 X<br />

Shunt trip flexible -21 STF-21 48…60 n/a 3VA9978-0BA21 3 1 X<br />

Shunt trip flexible -22 STF-22 110…127 n/a 3VA9978-0BA22 3 1 X<br />

Shunt trip flexible -23 STF-23 208…277 n/a 3VA9978-0BA23 3 1 X<br />

Shunt trip flexible -24 STF-24 380…500 n/a 3VA9978-0BA24 3 1 X<br />

Shunt trip flexible -25 STF-25 600 n/a 3VA9978-0BA25 3 1 X<br />

Right<br />

side opt.<br />

3VA6<br />

only<br />

Undervoltage release -10 UVR-10 n/a 12 3VA9978-0BB10 3 1 X<br />

Undervoltage release -11 UVR-11 n/a 24 3VA9978-0BB11 3 1 X<br />

Undervoltage release -12 UVR-12 n/a 48 3VA9978-0BB12 3 1 X<br />

Undervoltage release -14 UVR-14 n/a 125…127 3VA9978-0BB14 3 1 X<br />

Undervoltage release -16 UVR-16 n/a 250 3VA9978-0BB16 3 1 X<br />

Undervoltage release -20 UVR-20 24 n/a 3VA9978-0BB20 3 1 X<br />

Undervoltage release -24 UVR-24 120…127 n/a 3VA9978-0BB24 3 1 X<br />

Undervoltage release -25 UVR-25 208…230 n/a 3VA9978-0BB25 3 1 X<br />

Undervoltage release -27 UVR-27 440…480 n/a 3VA9978-0BB27 3 1 X<br />

Universal release UNI-11 n/a 12vdc 3VA9978-0BD11 3 1 X<br />

Universal release UNI-12 n/a 24vdc 3VA9978-0BD12 3 1 X<br />

Universal release UNI-13 n/a 48vdc 3VA9978-0BD13 3 1 X<br />

Internal Accessories<br />

Right or left side options<br />

3VA53/54 and 3VA63/64 (ETU)<br />

Auxiliary switch - standard AUX_HQ 240VAC n/a 3VA9978-0AA12 1 6 X X X X X X X X X X<br />

Leading Chg-over SW - standard LCS_HQ 240VAC n/a 3VA9978-0AA22 1 1 X<br />

Trip alarm (bell alarm) - standard TAS_HQ 240VAC 250VDC 3VA9978-0AB12 1 4 X X X X<br />

Electrical Alarm Switch std. (ETU 0nly) EAS_HQ 240VAC 250VDC 3VA9978-0AB22 1 1 X<br />

Auxiliary switch - high capacity a AUX_HP 600VAC n/a 3VA9978-0AA11 2 2<br />

X X X X<br />

X X X X<br />

Leading Chg-over SW - High Cap a LCS_HP 600VAC 250VDC 3VA9978-0AA21 1 1 X<br />

Trip alarm (bell alarm) - High Cap a TAS_HP 600VAC 250VDC 3VA9978-0AB11 2 2 X X<br />

Auxiliary switch - electronic d AUX_HQ_el 24VAC 24VDC 3VA9978-0AA13 1 6 X X X X X X X X X X<br />

Leading Chg-over SW - electronic d LCS_HQ_el 24VAC n/a 3VA9978-0AA23 1 1 X<br />

Trip alarm (bell alarm) - electronic d TAS_HQ_el 24VAC 24VDC 3VA9978-0AB13 1 4 X X X X<br />

Electrical Alarm Switch electronic d<br />

X<br />

EAS_HQ_el 24VAC 24VDC 3VA9978-0AB23 1 1<br />

(ETU 0nly)<br />

Ronis adapter FOR 3VA63/64 Ronis Adapter n/a n/a 3VA9347-0LF10 4 1 X<br />

Cylinder Lock (type Ronis) Key 1 Ronis Key 1 n/a n/a 3VA9980-0VL10<br />

one one<br />

Cylinder Lock (type Ronis) Key 2 Ronis Key 2 n/a n/a 3VA9980-0VL20<br />

installs in<br />

per per<br />

adapter<br />

Cylinder Lock (type Ronis) Key 3 Ronis Key 3 n/a n/a 3VA9980-0VL30 adapter<br />

adapter<br />

above<br />

Cylinder Lock (type Ronis) Key 4 Ronis Key 4 n/a n/a 3VA9980-0VL40<br />

a High capacity/power (HP) max. Amps load capacity is higher than standed module<br />

(.55A up to 6.0A) depends on Voltage and AC/DC requirements - see SpeedFax section<br />

7 or 3VA documentation for more information.<br />

b Many accessories available for the 3VA5 and 3VA6 breakers may not be suitable for use<br />

in Lighting Panelboards.<br />

– COMPAS allows options that are available. All accessories listed above can be used<br />

with Panelboards in general, but there will be exceptions.<br />

c Lugs are NOT supplied with loose breaker as standard - must order separately or<br />

configure in COMPAS to include lugs.<br />

– Factory assembled panels include AL lugs as standard, CU lugs are optional.<br />

These kits include 3 connectors and hardware.<br />

d Special electronically-compatible (el) variants are available for applications that require<br />

the auxiliary switch signals to be linked to low voltage systems.<br />

– May need special Mod in COMPAS.<br />

11-68<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3VA Breaker Configuration Information in Panelboards<br />

Revised on 02/29/20<br />

Internal and External Accessories for 400-600A 3VA Breakers<br />

Selection<br />

Description<br />

Accessories (continued)<br />

Quick<br />

reference<br />

code<br />

Voltage<br />

AC max<br />

or range<br />

Voltage<br />

DC max<br />

or range<br />

Accessory<br />

Catalog<br />

Number b<br />

Qty of<br />

slots in<br />

breaker<br />

req'd<br />

Max.<br />

Qty.<br />

per<br />

Brkr<br />

Position to install for<br />

3VA53/63 and<br />

3VA54/64 only<br />

Left side pocket Right side pocket<br />

Pocket reference # ==> 25 24 23 22 21 11 12 13 14 15<br />

11 PANELBOARDS<br />

Internal Accessories<br />

3VA63/64 (ETU) only<br />

Communications Module - 3VA63/64 COM060 n/a 24VDC 3VA9377-0TB10 4 1 X<br />

COM060-to-T-Connector<br />

ext. cable 0.4 m<br />

COM060-to-T-Connector<br />

ext. cable 0.8 m<br />

COM060-to-T n/a n/a 3VA9987-0TF20 n/a n/a<br />

COM060-to-T n/a n/a 3VA9987-0TF10 n/a n/a<br />

COM060 T-Connector (spare part) T-Connector n/a n/a 3VA9987-0TG10 n/a n/a<br />

External b Accessories<br />

and Field Kits<br />

#1-600 kcmil AL wire<br />

connector Kit c AL-lug n/a n/a 3VA9373-0JB13<br />

#1-600 kcmil CU wire<br />

connector Kit c CU-lug n/a n/a 3VA9373-0JD13<br />

2/0-600 kcmil AL 2 port<br />

connector Kit c AL-2lug n/a n/a 3VA9473-0JJ23<br />

2/0-600 kcmil CU 2 port<br />

connector Kit c CU-2lug n/a n/a 3VA9473-0JE23<br />

Compression Lugs<br />

(future offering - details tbd)<br />

TMTU<br />

or ETU<br />

600A max.<br />

tbd n/a n/a tbd n/a n/a<br />

Line or Load end as needed<br />

availability and<br />

usage locations tbd<br />

3VA53/63 or 54/64 PadLock Device tbd n/a n/a 3VA9338-0LB11 n/a n/a<br />

M0320 Motor Operator<br />

- 24-60V DC<br />

M0320 Motor Operator<br />

- 110-230V AC or 110-250V DC<br />

M0320 n/a 24-60V 3VA9277-0HA10 n/a 1 P4/P5 only<br />

M0320<br />

110-<br />

230V<br />

110-<br />

250V<br />

3VA9277-0HA20 n/a 1 P4/P5 only<br />

COM100 and COM800 modules and cables can be found on Communications Tables with ETU Breakers earlier in this section.<br />

a High capacity/power (HP) max. Amps load capacity is higher than standed module<br />

(.55A up to 6.0A) depends on Voltage and AC/DC requirements - see SpeedFax section<br />

7 or 3VA documentation for more information.<br />

b Many accessories available for the 3VA5 and 3VA6 breakers may not be suitable for use<br />

in Lighting Panelboards.<br />

– COMPAS allows options that are available. All accessories listed above can be used<br />

with Panelboards in general, but there will be exceptions."<br />

c Lugs are NOT supplied with loose breaker as standard - must order separately or configure<br />

in COMPAS to include lugs.<br />

– Factory assembled panels include AL lugs as standard, CU lugs are optional. These<br />

kits include 3 connectors and hardware.<br />

d Special electronically-compatible (el) variants are available for applications that require<br />

the auxiliary switch signals to be linked to low voltage systems.<br />

– May need special Mod in COMPAS.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-69


Panelboards<br />

Type P4 Panelboards<br />

Revised on 05/15/18<br />

General<br />

11<br />

PANELBOARDS<br />

Features<br />

The P4 panel has a medium sized<br />

footprint and fits a larger number of<br />

applications that require larger branch<br />

devices and higher amp ratings than<br />

what the lighting panel class offers.<br />

Even with the increased capacity, this<br />

panel is a space saver with its 32" width<br />

and 10" depth. The P4 panel offers a<br />

wide array of factory-assembled options<br />

and has the ability to mix breaker frames<br />

in unit space up to 800 amps and fusible<br />

switches up to 200 amps. Bussing<br />

options for the P4 vary from the standard<br />

temperature rated aluminum to<br />

temperature rated copper and 750A/SI<br />

aluminum and 1000A/SI copper designs.<br />

All aluminum bussing in the P4 panel is<br />

tin-plated as a standard. Silver-plated is<br />

offered as the default for copper bus and<br />

tin as an option. Integrated time clocks,<br />

bus mounted contactors as mains or<br />

submains, split bus and subfeed lugs (up<br />

to 600 amp) are just a few of the options<br />

of this flexible panel.<br />

The 3 panel configurations defined by<br />

the unit space allowed for a given<br />

amperage, main device and box height.<br />

The P4 panel starts with a 60" high box.<br />

All of the branch devices are unit space<br />

mounted. Breakers and switches can be<br />

mixed and matched to meet customer<br />

requirements.<br />

Enclosure Selection <br />

Main Lug / Main Breaker<br />

Enclosure – Standard Type 1 enclosure<br />

is 32" wide x 10" deep. The Box Height<br />

is determined by main device and unit<br />

space. See charts for box height.<br />

Voltage – 600V AC max.<br />

250V DC max.<br />

Amperage – 400-800 amp main breaker<br />

or 400-1200 amp main lug only.<br />

Short Circuit Rating – 200 KAIC max.<br />

symmetrical or equal to the lowest rated<br />

device installed unless a series rating is<br />

indicated. Panels with subfeed or<br />

feed-thru lugs without a main device,<br />

circuit breaker or fusible unit, are limited<br />

to a three-cycle rating. The three-cycle<br />

rating for the P4 panel is limited to 42<br />

KAIC. Note that the main device may<br />

be mounted remote from the panel.<br />

Bussing – The P4 panel has more<br />

options to meet market requirements.<br />

The standard bussing is temperature<br />

rated aluminum. The rating is per the<br />

requirements of UL 67 – the standard for<br />

panelboards. All aluminum bussing is<br />

tin-plated. Optional bussing for the P4<br />

panel is: 750 A/SI aluminum, temperature<br />

rated copper, and 1000 A/SI copper.<br />

The copper bus option for this panel<br />

is silver-plated.<br />

Available Circuit Space in Inches (mm)<br />

Enclosure Dimension in Inches (mm)<br />

Dimension “C”<br />

H W D Main Lug Main Breaker<br />

Type 1 and Type 3R/12 400-800A 400-800A<br />

60 (1524) 32 (813) 10 (254) 30 (762) 21.25 (540)<br />

75 (1905) 32 (813) 10 (254) 45 (1143) 36.25 (921)<br />

90 (2286) 32 (813) 10 (254) 60 (1524) 51.25 (1302)<br />

Weight – Approximate<br />

Total panelboard weight when filled<br />

with a normal quantity<br />

of breakers and accessories is about 8<br />

lbs. (1 kg) per inch<br />

(54g per mm) of box height.<br />

Main Lugs 1<br />

Ampere Rating<br />

Connectors Suitable for<br />

Copper or Aluminum<br />

400 (1) - #3/0 AWG-500 kcmil<br />

(2) - #3/0 AWG-250 kcmil<br />

600 (2) - #3/0 AWG-500 kcmil<br />

800 (3) - #3/0 AWG-500 kcmil<br />

1000 (4) - #3/0 AWG-500 kcmil<br />

1200 (4) - #3/0 AWG-500 kcmil<br />

a Alternate lugs for 750 kcmil cable are available, but<br />

result in significant loss of branch unit mounting space.<br />

Consult Siemens.<br />

Gauge Steel of Boxes<br />

Fronts, Surface and Flush<br />

Dimensions in<br />

inches (mm) Gauge Steel<br />

Width Height Box Fronts<br />

32"<br />

(813)<br />

60 - 75 - 90<br />

(1524, 1905,<br />

2286)<br />

#16 1 #14 (1 piece trim)<br />

#14 Ga (4 piece<br />

trim)<br />

#12 #12 (1 piece trim,<br />

door in door)<br />

#10 #10 (1 piece door<br />

trim in)<br />

#16 #16 (4 piece trim)<br />

a Box has 16 gauge side panels, 14 gauge backplates and<br />

12 gauge back support.<br />

Main Breaker Unit Space Dimensions<br />

Ampere<br />

Rating<br />

Breaker<br />

Type<br />

400 JXD6, JD6, HJXD6,<br />

HJD6,<br />

HHJXD6, HHJD6<br />

Breaker Dimensions in Inches (mm)<br />

Family A<br />

B<br />

Sentron 10.425 (265)<br />

400 NJ, HJ, LJ VL 12.500 (318)<br />

400 SJD6, SHJD6 Sentron 10.425 (265)<br />

400 CJD6, SCJD6 Sentron 8.250 (210)<br />

600 LXD6, LD6, HLXD6, Sentron 10.425 (265)<br />

HLD6, HHLXD6, HHLD6<br />

600 NL, HL, LL VL 11.250 (286)<br />

600 SLD6, SHLD6 Sentron 10.425 (265)<br />

600 CLD6, SCLD6 Sentron 8.250 (210)<br />

800 NM, HM, LM VL 10.500 (267)<br />

13.125 (333)<br />

a Standard trim is four piece without door. Surface or flush one piece trim is available for<br />

32 in. (813 mm) wide circuit breaker panel.<br />

Solid state (electronic) trip units only.<br />

11-70<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Panelboards<br />

Type P4 Panelboards<br />

Dimensions<br />

Main Breaker Selection<br />

Ampere<br />

Rating<br />

400<br />

600<br />

800<br />

Trip<br />

Type<br />

Thermal<br />

Magnetic<br />

Electronic<br />

(Solid state)<br />

Thermal<br />

Magnetic<br />

Electronic<br />

(Solid state)<br />

Thermal<br />

Magnetic<br />

Electronic<br />

(Solid state)<br />

Breaker<br />

Family<br />

Sentron<br />

VL<br />

Sentron<br />

Sentron<br />

VL<br />

Sentron<br />

VL<br />

VL<br />

Frame<br />

Type<br />

Maximum Interruption Rating (KAIC)<br />

240V 480V 600V<br />

Unit Space<br />

Requirements in<br />

Inches (mm)<br />

Trip Amperage<br />

JXD6, JD6 65,000 35,000 25,000 8.75 (222) 200, 225, 250, 300, 350, 400<br />

HJXD6, HJD6 100,000 65,000 35,000 8.75 (222) 200, 225, 250, 300, 350, 400<br />

HHJXD6, HHJD6 200,000 100,000 50,000 8.75 (222) 200, 225, 250, 300, 350, 400<br />

CJD6 200,000 150,000 100,000 8.75 (222) 200, 225, 250, 300, 350, 400<br />

NJ 65,000 35,000 25,000 6.25 (159) 250, 400<br />

HJ 100,000 65,000 25,000 6.25 (159) 250, 400<br />

LJ 200,000 100,000 25,000 6.25 (159) 250, 400<br />

SJD6 65,000 35,000 25,000 8.75 (222) 200, 300, 400<br />

SHJD6 100,000 65,000 35,000 8.75 (222) 200, 300, 400<br />

SCJD6 200,000 150,000 100,000 8.75 (222) 200, 300, 400<br />

LXD6 65,000 35,000 25,000 8.75 (222) 450, 500, 600<br />

LD6 65,000 35,000 25,000 8.75 (222) 250, 300, 350, 400, 450, 500, 600<br />

HLXD6, HLD6 100,000 65,000 35,000 8.75 (222) 250, 300, 350, 400, 450, 500, 600<br />

HHLXD6, HHLD6 200,000 100,000 50,000 8.75 (222) 250, 300, 350, 400, 450, 500, 600<br />

CLD6 200,000 150,000 100,000 8.75 (222) 250, 300, 350, 400, 450, 500, 600<br />

NL 65,000 35,000 25,000 6.25 (159) 400, 600<br />

HL 100,000 65,000 25,000 6.25 (159) 400, 600<br />

LL 200,000 100,000 25,000 6.25 (159) 400, 600<br />

SLD6 65,000 35,000 25,000 8.75 (222) 300, 400, 500, 600<br />

SHLD6 100,000 65,000 35,000 8.75 (222) 300, 400, 500, 600<br />

SCLD6 200,000 150,000 100,000 8.75 (222) 300, 400, 500, 600<br />

NM 65,000 35,000 25,000 8.75 (222) 600, 700, 800<br />

HM 100,000 65,000 35,000 8.75 (222) 600, 700, 800<br />

LM 200,000 100,000 50,000 8.75 (222) 600, 700, 800<br />

NM 65,000 35,000 25,000 8.75 (222) 600, 800<br />

HM 100,000 65,000 35,000 8.75 (222) 600, 800<br />

LM 200,000 100,000 50,000 8.75 (222) 600, 800<br />

11 PANELBOARDS<br />

Main Lugs Only Wire Bending Space<br />

Dimensions in inches (mm)<br />

Main Lug<br />

Neutral<br />

400A 600A 800A 1000A 1200A 400-600A 800-1200A<br />

Lugs A B C D E F G<br />

Standard 16.500 16.750 15.969 15.969 15.969 13.125 13.125<br />

(419) (419) (406) (406) (406) (333) (333)<br />

Oversize 16.500 21.750 25.969 25.969 25.969 18.125 23.125<br />

(419) (552) (660) (660) (660) (460) (587)<br />

Crimp 19.187 18.250 18.687 18.250 18.250 15.937 15.937<br />

(487) (464) (475) (464) (464) (405) (405)<br />

Standard 16.750 15.969 — — — 13.125 13.125<br />

w/Subfeed (425) (406) (333) (333)<br />

Standard 16.500 16.750 — — — 13.125 13.125<br />

w/Feed-thru (419) (419) (333) (333)<br />

Branch Switch Unit Space<br />

Mounting Height in inches (mm)<br />

Main Lugs Only Unit Space<br />

Ampere Number Twin Single AC Cables Per Connectors Suitable for<br />

Rating of Poles Mounted Mounted Voltage Connector Copper or Aluminum<br />

30-30 2, 3 2.50 (64) — 240 1 #14 - #8 AWG (Cu Only)<br />

30-30 2, 3 5.00 (127) — 240 1 #14 - #4 AWG<br />

30-60 2, 3 5.00 (127) — 240 1 #14 - #4 AWG<br />

60-60 2, 3 5.00 (127) — 240 1 #14 - #4 AWG<br />

60-100 2, 3 7.50 (191) — 240 1 #10 - #1/0 AWG<br />

100-100 2, 3 7.50 (191) — 240 1 #10 - #1/0 AWG<br />

200-200 3 10.00 (254) — 240 1 #6 AWG - 350 kcmil<br />

200 2 — 7.50 (191) 240 1 #6 AWG - 350 kcmil<br />

200 3 — 10.00 (254) 240 2 #6 AWG - 350 kcmil<br />

30-30 2, 3 7.5 (191) — 600 1 #14 - #8 AWG<br />

30-60 2, 3 7.5 (191) — 600 1 #14 - #4 AWG<br />

60-60 2, 3 7.5 (191) — 600 1 #14 - #4 AWG<br />

60-100 2, 3 7.5 (191) — 600 1 #10-#1/0 AWG<br />

100-100 2, 3 7.5 (191) — 600 1 #10-#1/0 AWG<br />

200-200 3 10.00 (254) — 600 1 #6 AWG - 250 kcmil<br />

100 2, 3 — 7.50 (191) 600 1 #10-#1/0 AWG<br />

200 2, 3 — 10.00 (254) 600 1 #6 AWG - 250 kcmil<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-71


Panelboards<br />

Type P4 Panelboards<br />

Revised on 04/30/19<br />

Dimensions<br />

11<br />

PANELBOARDS<br />

Branch Breaker Side Gutter Inches (mm)<br />

Reference<br />

Letter<br />

A 11.0 (279)<br />

B 10.98 (279)<br />

C 8.62 (219)<br />

D 7.0 (178)<br />

E 5.75 (146)<br />

F 5.25 (133)<br />

H 4.62 (177)<br />

I 8.76 (223)<br />

J 10.42 (265)<br />

K 10.0 (254)<br />

L 8.25 (210)<br />

M 10.0 (254)<br />

N 7.0 (178)<br />

O 5.0 (127)<br />

P 7.50 (191)<br />

Q 7.9 (200)<br />

R 7.9 (200)<br />

S 12.5 (318)<br />

T 11.25 (286)<br />

AA 7.06 (179)<br />

AB 6.55 (166)<br />

AC 6.55 (166)<br />

Panel Width 32 Inches<br />

Dimensions in inches (mm)<br />

A<br />

B<br />

BL, BLH, HBL, BQD, BLE, BLEH,<br />

BLR, BLF2, BLHF2, HBLF2,BLFB,<br />

BLHFB, BAF, BAHF, BGL, BQD<br />

NGB, HGB, LGB<br />

NGB2, HGB2, LGB2<br />

BL, BLH, HBL, BQD, BLE, BLEH,<br />

BLR, BLF2, BLHF2, HBLF2, BLFB,<br />

BLHFB, BAF, BAHF, BGL, BQD<br />

NGB, HGB, LGB<br />

NGB2, HGB2, LGB2<br />

D ED4, ED6, HED4 ED4, ED6, HED4 D<br />

H CED CED H<br />

E QR2, QRH2, HQR2, HQR2H QR2, QRH2, HQR2, HQR2H E<br />

F<br />

FXD6, FD6, HFXD6,<br />

HFD6, HHFXD6, HHFD6,<br />

SFD6, SHFD6<br />

FXD6, FD6, HFXD6,<br />

HFD6, HHFXD6, HHFD6<br />

SFD6, SHFD6<br />

AA 3VA52 – [MFAS, HFAS, CFAS] 3VA52 – [MFAS, HFAS, CFAS] AA<br />

Q ND, HD, LD ND, HD, LD Q<br />

AB<br />

3VA61 – [MDAE, HDAE,<br />

CDAE, LDAE]<br />

3VA61 – [MDAE, HDAE,<br />

CDAE, LDAE]<br />

R NF, HF, LF NF, HF, LF R<br />

AC<br />

3VA62 – [MFAE, HFAE,<br />

CFAE, LFAE]<br />

3VA62 – [MFAE, HFAE,<br />

CFAE, LFAE]<br />

I CFD6, SCFD6 I<br />

J<br />

JD6, JXD6, SJD6, HJD6, HXJD6, SHJD6, HHJD6,<br />

HHJXD6, LD6, LXD6, SLD6, HLD6, HXLD6, SHLD6,<br />

HHLD6, HHLXD6<br />

A<br />

B<br />

F<br />

AB<br />

AC<br />

J<br />

L CJD6, SCJD6, CLD6, SCLD6 L<br />

S NJ, HJ, LJ S<br />

T NL, HL, LL T<br />

K NM, HM, LM K<br />

M VB 30A, VB 60A (5”) VB 30A, VB 60A (5”) M<br />

N VB 30A, VB 60A (5”) VB 30A, VB 60A (5”) N<br />

O VB 100 - 200A VB 100 - 200A O<br />

P VB 100 - 200A Single P<br />

11-72<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Panelboards<br />

Power and Distribution<br />

Type P4<br />

Shown with Standard Mains, Top Fed and Surface Trim<br />

Catalog number is for aluminum main<br />

bus. For optional copper main bus<br />

change “A” in position 11 to “E” (silverplated<br />

copper bus).<br />

a For 600V application, change “F” in position 3 to “G”. See alternate<br />

main breaker table on page 11-74 for 600V rated mains. Change position<br />

5 and 6 and add price from table. Price only 600V rated branch breakers.<br />

Panels are top feed, surface mounted.<br />

For bottom feed, change “T” in position<br />

12 to “B”. For flush mounting,<br />

change “S” in position 13 to “F”.<br />

Replace fifth and sixth position<br />

in panelboard catalog number,<br />

with alternate main breaker code.<br />

Use price adders from main breaker<br />

section table. Horizontally mounted.<br />

Main Lugs Only — shown with aluminum bus, top fed, and surface trims.<br />

Unit<br />

208Y/120V 240/120V 120/240V or 250 V DC Max<br />

Maximum<br />

Panel Amps<br />

Space<br />

(inches)<br />

3-Phase, 4-Wire<br />

Catalog Number<br />

3-Phase, 4-Wire<br />

Catalog Number<br />

1-Phase, 3-Wire<br />

Catalog Number<br />

30 P4C60ML400ATS P4B60ML400ATS P4A60ML400ATS<br />

400<br />

45 P4C75ML400ATS P4B75ML400ATS P4A75ML400ATS<br />

60 P4C90ML400ATS P4B90ML400ATS P4A90ML400ATS<br />

30 P4C60ML600ATS P4B60ML600ATS P4A60ML600ATS<br />

600<br />

45 P4C75ML600ATS P4B75ML600ATS P4A75ML600ATS<br />

60 P4C90ML600ATS P4B90ML600ATS P4A90ML600ATS<br />

30 P4C60ML800ATS P4B60ML800ATS P4A60ML800ATS<br />

800<br />

45 P4C75ML800ATS P4B75ML800ATS P4A75ML800ATS<br />

60 P4C90ML800ATS P4B90ML800ATS P4A90ML800ATS<br />

30 P4C60ML101ATS P4B60ML101ATS P4A60ML101ATS<br />

1000<br />

45 P4C75ML101ATS P4B75ML101ATS P4A75ML101ATS<br />

60 P4C90ML101ATS P4B90ML101ATS P4A90ML101ATS<br />

30 P4C60ML120ATS P4B60ML120ATS P4A60ML120ATS<br />

1200<br />

45 P4C75ML120ATS P4B75ML120ATS P4A75ML120ATS<br />

60 P4C90ML120ATS P4B90ML120ATS P4A90ML120ATS<br />

Maximum<br />

Panel Amps<br />

Unit<br />

Space<br />

(inches)<br />

240V 480Y/277V 480V a<br />

3-Phase, 3-Wire<br />

Catalog Number<br />

3-Phase, 4-Wire<br />

Catalog Number<br />

3-Phase, 3-Wire<br />

Catalog Number<br />

30 P4D60ML400ATS P4E60ML400ATS P4F60ML400ATS<br />

400<br />

45 P4D75ML400ATS P4E75ML400ATS P4F75ML400ATS<br />

60 P4D90ML400ATS P4E90ML400ATS P4F90ML400ATS<br />

30 P4D60ML600ATS P4E60ML600ATS P4F60ML600ATS<br />

600<br />

45 P4D75ML600ATS P4E75ML600ATS P4F75ML600ATS<br />

60 P4D90ML600ATS P4E90ML600ATS P4F90ML600ATS<br />

30 P4D60ML800ATS P4E60ML800ATS P4F60ML800ATS<br />

800<br />

45 P4D75ML800ATS P4E75ML800ATS P4F75ML800ATS<br />

60 P4D90ML800ATS P4E90ML800ATS P4F90ML800ATS<br />

30 P4D60ML101ATS P4E60ML101ATS P4F60ML101ATS<br />

1000<br />

45 P4D75ML101ATS P4E75ML101ATS P4F75ML101ATS<br />

60 P4D90ML101ATS P4E90ML101ATS P4F90ML101ATS<br />

30 P4D60ML120ATS P4E60ML120ATS P4F60ML120ATS<br />

1200<br />

45 P4D75ML120ATS P4E75ML120ATS P4F75ML120ATS<br />

60 P4D90ML120ATS P4E90ML120ATS P4F90ML120ATS<br />

Main Circuit Breaker — shown with standard mains, aluminum bus, top fed, and surface trims.<br />

Maximum<br />

Panel Amps<br />

400<br />

600<br />

800<br />

Maximum<br />

Panel Amps<br />

400<br />

600<br />

800<br />

Unit<br />

Space<br />

(inches)<br />

208Y/120V 240/120V 120/240V or 250 Vdc Max<br />

3-Phase, 4-Wire<br />

Catalog Number<br />

3-Phase, 4-Wire<br />

Catalog Number<br />

1-Phase, 3-Wire<br />

Catalog Number<br />

21.25 P4C60JX400ATS P4B60JX400ATS P4A60JX400ATS<br />

36.25 P4C75JX400ATS P4B75JX400ATS P4A75JX400ATS<br />

51.25 P4C90JX400ATS P4B90JX400ATS P4A90JX400ATS<br />

21.25 P4C60LX600ATS P4B60LX600ATS P4A60LX600ATS<br />

36.25 P4C75LX600ATS P4B75LX600ATS P4A75LX600ATS<br />

51.25 P4C90LX600ATS P4B90LX600ATS P4A90LX600ATS<br />

21.25 P4C60M1800ATS P4B60M1800ATS P4A60M1800ATS<br />

36.25 P4C75M1800ATS P4B75M1800ATS P4A75M1800ATS<br />

51.25 P4C90M1800ATS P4B90M1800ATS P4A90M1800ATS<br />

Unit<br />

Space<br />

(inches)<br />

240V 480Y/277V 480V a<br />

3-Phase, 3-Wire<br />

Catalog Number<br />

3-Phase, 4-Wire<br />

Catalog Number<br />

3-Phase, 3-Wire<br />

Catalog Number<br />

21.25 P4D60JX400ATS P4E60JX400ATS P4F60JX400ATS<br />

36.25 P4D75JX400ATS P4E75JX400ATS P4F75JX400ATS<br />

51.25 P4D90JX400ATS P4E90JX400ATS P4F90JX400ATS<br />

21.25 P4D60LX600ATS P4E60LX600ATS P4F60LX600ATS<br />

36.25 P4D75LX600ATS P4E75LX600ATS P4F75LX600ATS<br />

51.25 P4D90LX600ATS P4E90LX600ATS P4F90LX600ATS<br />

21.25 P4D60M1800ATS P4E60M1800ATS P4F60M1800ATS<br />

36.25 P4D75M1800ATS P4E75M1800ATS P4F75M1800ATS<br />

51.25 P4D90M1800ATS P4E90M1800ATS P4F90M1800ATS<br />

Selection<br />

11 PANELBOARDS<br />

Product Category PBSB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-73


Panelboards<br />

Power and Distribution<br />

Revised on 04/30/19<br />

Selection<br />

11<br />

Type P4<br />

Alternate Main Breaker Selection<br />

PANELBOARDS<br />

Breaker<br />

Frame<br />

Rating<br />

400<br />

Trip<br />

Type<br />

Thermal<br />

Magnetic<br />

Breaker<br />

Family<br />

Sentron<br />

Frame<br />

Type<br />

Type<br />

Reference<br />

Code<br />

Trip<br />

Amperage<br />

Unit Space<br />

Requirements<br />

in Inches<br />

Maximum Interruption<br />

Rating (KAIC) Volts AC<br />

240 480 600<br />

JXD6 JX 200, 225, 250, 300, 350, 400 8.75 65,000 35,000 25,000<br />

JD6 J6 200, 225, 250, 300, 350, 400 8.75 65,000 35,000 25,000<br />

HJXD6 H5 200, 225, 250, 300, 350, 400 8.75 100,000 65,000 35,000<br />

HJD6 H6 200, 225, 250, 300, 350, 400 8.75 100,000 65,000 35,000<br />

HHJXD6 H9 200, 225, 250, 300, 350, 400 8.75 200,000 100,000 50,000<br />

HHJD6 6H 200, 225, 250, 300, 350, 400 8.75 200,000 100,000 50,000<br />

CJD6 CJ 200, 225, 250, 300, 350, 400 8.75 200,000 150,000 100,000<br />

Electronic<br />

(Solid<br />

state)<br />

VL<br />

Sentron<br />

NJ J1 250, 400 6.25 65,000 35,000 25,000<br />

HJ J7 250, 400 6.25 100,000 65,000 25,000<br />

LJ J3 250, 400 6.25 200,000 100,000 25,000<br />

SJD6 SJ 200, 300, 400 8.75 65,000 35,000 25,000<br />

SHJD6 SX 200, 300, 400 8.75 100,000 65,000 35,000<br />

SCJD6 SC 200, 300, 400 8.75 200,000 150,000 100,000<br />

600<br />

Thermal<br />

Magnetic<br />

Sentron<br />

LXD6 LX 450, 500, 600 8.75 65,000 35,000 25,000<br />

LD6 L6 250, 300, 350, 400, 450, 500, 600 8.75 65,000 35,000 25,000<br />

HLXD6 HO 250, 300, 350, 400, 450, 500, 600 8.75 100,000 65,000 35,000<br />

HLD6 HL 250, 300, 350, 400, 450, 500, 600 8.75 100,000 65,000 35,000<br />

HHLXD6 XH 250, 300, 350, 400, 450, 500, 600 8.75 200,000 100,000 50,000<br />

HHLD6 HH 250, 300, 350, 400, 450, 500, 600 8.75 200,000 100,000 50,000<br />

CLD6 CL 250, 300, 350, 400, 450, 500, 600 8.75 200,000 150,000 100,000<br />

Electronic<br />

(Solid<br />

state)<br />

VL<br />

Sentron<br />

NL L7 400, 600 6.25 65,000 35,000 25,000<br />

HL L2 400, 600 6.25 100,000 65,000 25,000<br />

LL SL 400, 600 6.25 200,000 100,000 25,000<br />

SLD6 L6 300, 400, 500, 600 8.75 65,000 35,000 25,000<br />

SHLD6 S2 300, 400, 500, 600 8.75 100,000 65,000 35,000<br />

SCLD6 SI 300, 400, 500, 600 8.75 200,000 150,000 100,000<br />

800<br />

Thermal<br />

Magnetic<br />

VL NM M1 600, 700, 800 8.75 65,000 35,000 25,000<br />

HM M2 600, 700, 800 8.75 100,000 65,000 35,000<br />

LM M3 600, 700, 800 8.75 200,000 100,000 50,000<br />

LMXD6 LM 500, 600, 700, 800 8.75 65,000 50,000 25,000<br />

Sentron<br />

LMD6 L1 500, 600, 700, 800 8.75 65,000 50,000 25,000<br />

HLMXD6 HK 500, 600, 700, 800 8.75 100,000 65,000 50,000<br />

HLMD6 HJ 500, 600, 700, 800 8.75 100,000 65,000 50,000<br />

Electronic<br />

(Solid<br />

state)<br />

VL<br />

NM M1 600, 800 8.75 65,000 35,000 25,000<br />

HM M2 600, 800 8.75 100,000 65,000 35,000<br />

LM M3 600, 800 8.75 200,000 100,000 50,000<br />

For inches / millimeters conversion, see Application Data<br />

section.<br />

11-74<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category PBSB


Panelboards<br />

Power and Distribution<br />

Revised on 04/30/19<br />

Selection<br />

P4 Branch Circuit Breakers<br />

Amp<br />

Rating<br />

100<br />

xx<br />

125<br />

150<br />

225<br />

250<br />

Trip<br />

Type<br />

Thermal<br />

Magnetic<br />

Breaker<br />

Family<br />

BL<br />

Special BLG<br />

Application BL<br />

Thermal<br />

Magnetic<br />

BQD<br />

Electronic<br />

and misc.<br />

Thermal<br />

Magnetic<br />

Electronic<br />

(Solid<br />

state)<br />

Electronic<br />

(Solid<br />

state)<br />

Thermal<br />

Magnetic<br />

Thermal<br />

Magnetic<br />

Electronic<br />

(Solid<br />

state)<br />

Thermal<br />

Magnetic<br />

Electronic<br />

(Solid<br />

state)<br />

BL<br />

GB<br />

Sentron<br />

GB2<br />

3VA41 c<br />

VL<br />

3VA61 c<br />

(ETU350 LSI<br />

standard)<br />

General<br />

Application<br />

Sentron<br />

VL<br />

3VA52 c<br />

(W/TM230<br />

trip)<br />

3VA62 c<br />

(ETU350 LSI<br />

standard)<br />

Breaker<br />

Type<br />

1-Pole<br />

Max IR (kA) at<br />

120V 277V 347V<br />

125V<br />

DC<br />

Amp<br />

Ratings<br />

Avail.<br />

2-Pole and 3-Pole<br />

Max IR (kA) at<br />

120/<br />

240V<br />

240V<br />

480Y/<br />

277V<br />

480V<br />

600Y/<br />

347V<br />

600V<br />

125/<br />

250V<br />

DC<br />

250V<br />

DC<br />

Amp<br />

Ratings<br />

Avail.<br />

S = Single Mount<br />

S<br />

T = Twin mount<br />

T<br />

Unit Max<br />

Space 1-pole<br />

per Kit Circuits<br />

(in.) per Kit<br />

BL 10 — — — 15-70 10 10 — — — — — — 15-100 d — T 3.75 e 6<br />

BLH 22 — — — 15-70 22 22 — — — — — — 15-100 d — T 3.75 e 6<br />

HBL 65 — — — 15-50 65 65 — — — — — — 15-100 — T 3.75 e 6<br />

BLG a 10 — — — 15-20 10 — — — — — — — 30 — T 3.75 e 6<br />

BL (HID) 10 — — — 15-30 10 — — — — — — — 15-30 — T 3.75 e 6<br />

BQD f 65 14 — 14 15-100 — 65 14 — — — 14 — 15-100 — T 3.75 e 6<br />

BQD6 g 65 — — 14 15-70 — 65 — 10 — 14 — 15-70 — T 3.75 e 6<br />

AFCI/<br />

GFCI<br />

& Dual<br />

Function<br />

x — — —<br />

see<br />

special<br />

table<br />

page<br />

11-13<br />

x — — — — — — —<br />

see<br />

special<br />

table<br />

page<br />

11-13<br />

— T 3.75 e 6<br />

NGB 100 25 14 14 15-125 — 100 25 — 14 — 14 — 15-125 — T 3.75 e 6<br />

HGB 100 35 14 14 15-125 — 100 35 — 14 — 14 — 15-125 — T 3.75 e 6<br />

LGB 100 65 14 14 15-125 — 100 65 — 14 — 14 — 15-125 — T 3.75 e 6<br />

ED4 — 22 — 30 15-100 — 65 — 18 — — — 30 15-125 — T 3.75 e 6<br />

ED6 — — — — — — 65 — 25 — 18 — 30 20-125 — T 3.75 e 6<br />

HED4 b — — — — — — 65 — 42 — 18 — 30 15-125 — T 3.75 e 6<br />

HHED6 — — — — — — 100 — 65 — 18 — — 15-50 — T 3.75 e 6<br />

NGB2 100 25 14 14 d 15-125 — 100 — 25 14 — 14 d — 15-125 — T 3.75 e 6<br />

HGB2 100 35 22 14 d 15-125 — 100 — 35 22 — 14 d — 15-125 — T 3.75 e 6<br />

LGB2 100 65 25 14 d 15-125 — 100 — 65 25 — 14 d — 15-125 — T 3.75 e 6<br />

info not x x x x x x x — x — — x 6<br />

yet available<br />

x x x x x x x — x — — x 6<br />

x x x x x x x — x — — x 6<br />

ND — — — — — — 65 — 35 18 — — — 60-150 — T 5.00 6<br />

HD — — — — — — 100 — 65 20 — — — 60-150 — T 5.00 6<br />

LD — — — — — — 200 — 100 25 — — — 60-150 — T 5.00 6<br />

MDAE — — — — — 100 35 35 18 18 — — 40-150 — T 5.00 6<br />

HDAE — — — — — 100 65 65 22 22 — — 40-150 — T 5.00 6<br />

CDAE — — — — — 200 100 100 35 35 — — 40-150 — T 5.00 6<br />

LDAE — — — — — 200 150 150 50 50 — — 40-150 — T 5.00 6<br />

QR2 — — — — — — 10 — — — — — — 100-225 — T 5.00 6<br />

QRH2 — — — — — — 25 — — — — — — 100-225 — T 5.00 6<br />

HQR2 — — — — — — 65 — — — — — — 100-225 — T 5.00 6<br />

HQR2H — — — — — — 100 — — — — — — 100-225 — T 5.00 6<br />

FXD6,<br />

FD6<br />

— — — — — — 65 — 35 — 22 — 30 70-250 S T 5.00 3 or 6<br />

HFXD6,<br />

HFD6<br />

— — — — — — 100 — 65 — 25 — 30 70-250 S T 5.00 3 or 6<br />

HHFXD6,<br />

—<br />

HHFD6<br />

— — — — — 200 — 100 — 25 — — 70-250 S T 5.00 3 or 6<br />

CFD6 — — — — — — 200 — 200 — 100 — 30 70-250 S - 5.00 3<br />

NF — — — — — — 65 — 35 18 — — — 100-250 S T 5.00 3 or 6<br />

HF — — — — — — 100 — 65 20 — — — 100-250 S T 5.00 3 or 6<br />

LF — — — — — — 200 — 100 25 — — — 100-250 S T 5.00 3 or 6<br />

MFAS — — — — — 85 85 — 35 — 18 — 50 100-250 — T 5.00 6<br />

HFAS — — — — — 100 100 — 65 — 25 — 85 100-250 — T 5.00 6<br />

CFAS — — — — — 200 200 — 100 — 35 — 100 100-250 — T 5.00 6<br />

MFAE — — — — — — 100 35 35 18 — — — 100-250 — T 5.00 6<br />

HFAE — — — — — — 100 65 65 22 — — — 100-250 — T 5.00 6<br />

CFAE — — — — — — 200 100 100 35 — — — 100-250 — T 5.00 6<br />

LFAE — — — — — — 200 150 150 50 — — — 100-250 — T 5.00 6<br />

11 PANELBOARDS<br />

a BLG two-pole breaker is one phase and neutral. Three<br />

pole is two phases and neutral - See SpeedFax page 7-31<br />

b 1-pole HED 15-30A rated 65kA; 35-100A rated 25kA:<br />

3-pole HED rated 42kA<br />

c Availability and additional specs tbd, expected late 2019.<br />

(COMPAS may allow selection of alternate trip units)<br />

d 2-pole only or two outer poles of 3-pole breaker<br />

e Accessories such as shunt trips on 3 pole breakers<br />

require 6.25" of unit space<br />

f Approved for CSA and UL Listed.<br />

g Approved for CSA but not UL Listed.<br />

Product Category PBSB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-75


Panelboards<br />

Power and Distribution<br />

Revised on 04/30/19<br />

Selection<br />

11<br />

PANELBOARDS<br />

P4 Branch Circuit Breakers<br />

(cont.)<br />

Amp<br />

Rating<br />

400<br />

600<br />

800<br />

Trip<br />

Type<br />

Thermal<br />

Magnetic<br />

Electronic<br />

(Solid<br />

state)<br />

Thermal<br />

Magnetic<br />

Electronic<br />

(Solid<br />

state)<br />

Thermal<br />

Magnetic<br />

Electronic<br />

(Solid<br />

state)<br />

Breaker<br />

Family<br />

Sentron<br />

VL<br />

Sentron<br />

Sentron<br />

VL<br />

Sentron<br />

VL<br />

Breaker<br />

Type<br />

JXD6,<br />

JD6<br />

HJXD6,<br />

HJD6<br />

HHJXD6,<br />

HHJD6<br />

1-Pole<br />

Max IR (kA) at<br />

120V 277V 347V<br />

125V<br />

DC<br />

Amp<br />

Ratings<br />

Avail.<br />

2-Pole and 3-Pole<br />

Max IR (kA) at<br />

120/<br />

240V<br />

240V<br />

480Y/<br />

277V<br />

480V<br />

600Y/<br />

347V<br />

600V<br />

125/<br />

250V<br />

DC<br />

250V<br />

DC<br />

Amp<br />

Ratings<br />

Avail.<br />

S = Single Mount<br />

S<br />

T = Twin mount<br />

T<br />

Unit Max<br />

Space 1-pole<br />

per Kit Circuits<br />

(in.) per Kit<br />

— — — — — — 65 — 35 — 25 — 30 200-400 S — 8.75 3<br />

— — — — — — 100 — 65 — 35 — 30 200-400 S — 8.75 3<br />

— — — — — — 200 — 100 — 50 — — 200-400 S — 8.75 3<br />

CJD6 — — — — — — 200 — 150 — 100 — 30 200-400 S — 8.75 3<br />

NJ — — — — — — 65 — 35 — 25 — — 250-400 S — 6.25 3<br />

HJ — — — — — — 100 — 65 — 25 — — 250-400 S — 6.25 3<br />

LJ — — — — — — 200 — 100 — 25 — — 250-400 S — 6.25 3<br />

SJD6 — — — — — — 65 — 35 — 25 — — 200-400 S — 8.75 3<br />

SHJD6 — — — — — — 100 — 65 — 35 — — 200-400 S — 8.75 3<br />

SCJD6 — — — — — — 200 — 100 — 100 — — 200-400 S — 8.75 3<br />

LXD6 — — — — — — 65 — 35 — 25 — 30 450-600 S — 8.75 3<br />

LD6 — — — — — — 65 — 35 — 25 — 30 250-600 S — 8.75 3<br />

HLXD6,<br />

HLD6<br />

— — — — — — 100 — 65 — 35 — 30 250-600 S — 8.75 3<br />

HHLXD6,<br />

—<br />

HHLD6<br />

— — — — — 200 — 100 — 50 — — 250-600 S — 8.75 3<br />

CLD6 — — — — — — 200 — 150 — 100 — — 250-600 S — 8.75 3<br />

NL — — — — — — 65 — 35 — 18 — — 400-600 S — 6.25 3<br />

HL — — — — — — 100 — 65 — 18 — — 400-600 S — 6.25 3<br />

LL — — — — — — 200 — 100 — 18 — — 400-600 S — 6.25 3<br />

SLD6 — — — — — — 65 — 35 — 25 — — 300-600 S — 8.75 3<br />

SHLD6 — — — — — — 100 — 65 — 35 — — 300-600 S — 8.75 3<br />

SCLD6 — — — — — — 200 — 150 — 100 — — 300-600 S — 8.75 3<br />

NM — — — — — — 65 — 35 — 25 — 22 600-800 S — 8.75 3<br />

HM — — — — — — 100 — 65 — 35 — 25 600-800 S — 8.75 3<br />

LM — — — — — — 200 — 100 — 50 — 42 600-800 S — 8.75 3<br />

NM — — — — — — 65 — 35 — 25 — — 600-800 S — 8.75 3<br />

HM — — — — — — 100 — 65 — 35 — — 600-800 S — 8.75 3<br />

LM — — — — — — 200 — 100 — 50 — — 600-800 S — 8.75 3<br />

a BLG two-pole breaker is one phase and neutral. Three<br />

pole is two phases and neutral - See SpeedFax page 7-31<br />

b 1-pole HED 15-30A rated 65kA; 35-100A rated 25kA:<br />

3-pole HED rated 42kA<br />

c Availability and additional specs tbd, expected late 2019.<br />

(COMPAS may allow selection of alternate trip units)<br />

d 2-pole only or two outer poles of 3-pole breaker<br />

e Accessories such as shunt trips on 3 pole breakers<br />

require 6.25" of unit space<br />

f Approved for CSA and UL Listed.<br />

g Approved for CSA but not UL Listed.<br />

11-76<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Panelboards<br />

Power and Distribution<br />

Revised on 04/30/19<br />

Selection<br />

Type S4/P4/SPP (10" deep) and F1/P4/FPP (10" deep)<br />

Connecting Strap Kits — w/o Circuit Breaker<br />

For use with Type P4, Type S4 or Sentron SPP Shallow depth panelboards<br />

Max<br />

Amp<br />

Rating<br />

Breaker<br />

Family<br />

Breaker<br />

Type<br />

Catalog<br />

Number <br />

Unit<br />

Height<br />

(inches)<br />

Mounting<br />

100 General BL, BQD SBL 3.75 Twin<br />

General xGB SNB 3.75 Twin<br />

125<br />

General xGB2 SGB2 3.75 Twin<br />

General ED SE6 3.75 Twin<br />

General CED SCE 3.75 Twin<br />

150 VL DG SDG 5.00 Twin<br />

3VA 3VA61 S3VA52T h 5.00 Twin<br />

225 General QR SQR 5.00 Twin<br />

VL FG SFG 5.00 Twin<br />

250<br />

Sentron FD SF6 5.00 Twin<br />

Sentron CFD SCF 5.00 Single<br />

3VA 3VA52, 3VA62 i S3VA52T h 5.00 Twin<br />

VL JG SJG 6.25 Single<br />

Sentron JD SJ1 8.75 Single<br />

400 Sentron CJD SCJ 8.75 Single<br />

Sentron SJD SSJ1 8.75 Single<br />

Sentron SCJD SSCJ 8.75 Single<br />

VL LG SLG 6.25 Single<br />

Sentron LD SL6 8.75 Single<br />

600 Sentron CLD SCL 8.75 Single<br />

Sentron SLD SSL6 8.75 Single<br />

Sentron SCLD SSCL 8.75 Single<br />

800 VL MG MG1 8.75 Single<br />

Branch Switch Selection<br />

Ampere<br />

Rating<br />

240V — Twin Mounted<br />

Mounting<br />

Height (inches)<br />

NEC Fuse Clips b<br />

30-30 2½ c<br />

30-30 5<br />

30-60 5<br />

60-60 5<br />

60-100 7½<br />

100-100 7½<br />

200-200 10<br />

240V — Single Mounted<br />

NEC Fuse Clips b<br />

30 7½<br />

60 7½<br />

100 7½<br />

200 10<br />

200 7½<br />

600V — Twin Mounted<br />

NEC Fuse Clips b<br />

30-30 7½<br />

30-60 7½<br />

60-60 7½<br />

60-100 7½<br />

100-100 7½<br />

200-200 10<br />

600V — Single Mounted<br />

NEC Fuse Clips b<br />

100 7½<br />

200 10<br />

11 PANELBOARDS<br />

3VA Breaker Provision Kits<br />

Breaker Type Catalog Number Description<br />

3VA52, 3VA61 or<br />

3VA62 Breaker<br />

S3VA52PR<br />

Contains the necessary<br />

hardware to land breaker<br />

on an existing strap kit<br />

Service Entrance Barriers<br />

Field installable Barriers to meet UL 67 service entrance requirements<br />

Breaker Type<br />

Catalog Number<br />

(S)JD, (S)LD, MG<br />

SEBP4V1<br />

CJD, CLD<br />

SEBP4V2<br />

JG, LG<br />

SEBP4V3<br />

Connecting Strap Kits d Fusible<br />

For use with Sentron Shallow Depth or Type SPP/FPP/F1/P4 power panels<br />

Ampere Rating Unit Height (inches) 10" Deep Box Catalog Number<br />

30–30 2.5 F602<br />

30–60 5, 7.5 F657<br />

30–60 5, 7.5 F657<br />

60–60 5, 7.5 F657<br />

60–100 5, 7.5 F657<br />

100–100 5, 7.5 F657<br />

100 7.5 F657<br />

200 10 F671<br />

200–200 10 F672<br />

Blank Plates — Circuit Breaker and Vacu-Break<br />

For use with Type P4, Type S4 or Sentron SPP Shallow<br />

depth panelboards<br />

Height<br />

(inches)<br />

Filler Plates<br />

For use with Type P4, Type S4 or Sentron SPP Shallow<br />

depth panelboards<br />

Filler Plate<br />

Breaker Type<br />

Catalog Number<br />

BL, BLH, HBL ED4, ED6,<br />

HED4, HHED6, NGB, HGB, DFFP1 e<br />

LGB, NGB2, HGB2, LGB2<br />

NEB, HEB<br />

Catalog<br />

Number<br />

1.25 6FPB01<br />

2.5 6FPB02<br />

3.75 6FPB03<br />

5.0 6FPB05<br />

10.0 6FPB10<br />

EBF1<br />

Cover Plates<br />

For use with Sentron Shallow Depth or<br />

Type SPP/FPP/F1/P4 power panels<br />

Breaker Type<br />

Catalog Number<br />

QR<br />

SQRC <br />

For inches / millimeters conversion, see Application Data section.<br />

a Includes housing frame plate without breaker handle<br />

opening. Provisions include all necessary mounting<br />

hardware less breakers.<br />

b For Class J, R or T fuse clip prices, refer to page 11-78.<br />

For Class J fuse clips price 600V, 7 1 ⁄2" high units.<br />

c NEC fuse clips only.<br />

d Normal stock item.<br />

Suitable to replace QF3 in P1 thru P5 Panelboards and<br />

Switchboards.<br />

To replace a QJ with a QR only a new cover is needed<br />

up to 225A<br />

Although QR is rated 250A, it is limited to 225A in<br />

panelboard.<br />

h To field install a single 3VA52, 3VA61 or 3VA62 breaker<br />

to an existing strap, provision kit #S3VA52PR is required.<br />

i 3VA62 breaker will be available in Fall 2019.<br />

Product Category PBSB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-77


Panelboards<br />

Modifications and Additions<br />

Revised on 05/15/18<br />

Selection<br />

11<br />

PANELBOARDS<br />

P4 Panelboards<br />

Devices Mounted on Gutter Cover<br />

Includes Device, Mounting – Wired or<br />

Unwired<br />

Description<br />

One piece front with door<br />

Hinged Gutter Covers 4 pc front<br />

Toggle Switch — SPST or 3-way<br />

15A, 277V maximum<br />

Pilot Light — General Purpose<br />

Neon or Incandescent<br />

Pushbutton<br />

Increased Capacity Neutral<br />

Ampere Rating<br />

Unit Space<br />

Phase Neutral ( inches)<br />

400 600 0<br />

400 800 0<br />

600 1200 0<br />

800 1200 0<br />

Subfeed or Feed-Thru Lugs<br />

(One Set Per Panel)<br />

Subfeed Double Lugs<br />

(Main Lug Panels)<br />

Amp<br />

Rating<br />

400 0<br />

600 0<br />

800 N/A<br />

1200 N/A<br />

Feed-Thru Lugs<br />

Unit Spaces<br />

(Additional inches)<br />

MLO<br />

Ampere Rating Unit Space (inches)<br />

400 10<br />

600 10<br />

800 17.5<br />

1200 17.5<br />

Fuse Clip Provisions<br />

(Add to 250 Volts or 600 Volts<br />

Unit Prices Per Switch)<br />

Amp<br />

Rating<br />

Class<br />

J<br />

Class<br />

R<br />

30 • •<br />

60 • •<br />

100 • •<br />

200 • •<br />

Class<br />

T<br />

Spanner Wrenches<br />

(for Vacu-Break Switches)<br />

Ground Fault on Main Breaker<br />

Description<br />

Conventional Ground Fault Includes:<br />

ground fault relay, ground sensor, CPT<br />

& shunt trip<br />

Test and Monitor Panel <br />

Ground Fault add to<br />

Sensitrip III breaker price<br />

Time Clocks <br />

Sangamo, Tork or Paragon time clock<br />

can be supplied, mounted in panelboard<br />

cabinet. For required increase in enclosure<br />

dimension, consult local sales office.<br />

Description<br />

Time clock (1- or 2-Pole, Single or<br />

Double Throw Contacts; 3-Pole Single<br />

Throw)<br />

277V Maximum with Plain Dial<br />

Optional:<br />

Astronomical Dial<br />

An Omitting Device<br />

Reserve Power or Carryover<br />

Space and Mounting Provisions Only<br />

Main Bus<br />

Standard main bus and ground bus are<br />

tin-plated aluminum. For copper main<br />

bus, neutral bus and ground bus, add<br />

from the table for each panel.<br />

Lugs – For Main Lug Only Panels<br />

Standard main lugs and neutral lugs<br />

are tin-plated aluminum, UL listed for<br />

use with aluminum/copper cables.<br />

Copper only lugs are an option.<br />

Ampere Rating<br />

400 - 1200<br />

Shunt Trip on Main and Branches <br />

Description<br />

BL, BQD, NGB, HGB, LGB, NGB2, HGB2,<br />

LGB2 (branch only)<br />

QR2, QRH2, HQR2, HQR2H,<br />

ED4, ED6, HED4, HHED6, CED6<br />

All others to 800A<br />

100% Rated Main Circuit Breakers<br />

Ampere<br />

Rating<br />

400A<br />

600A<br />

Breaker<br />

Type<br />

JXD6H, HJXD6H<br />

SCJD6H, SHJD6H<br />

NJY, HJY, LJY<br />

LXD6H, HLXD6H<br />

NMY , HMY , LMY <br />

Grounding of Panelboards Ground<br />

Bars (except for brazed-to-box)<br />

are shipped with the panel interior<br />

factory mounted.<br />

▪ Non-Insulated Equipment Ground<br />

Bar – Standard<br />

▪ Copper Non-Insulated Ground Bar<br />

▪ Al Insulated Equipment Ground Bar<br />

▪ Cu Insulated Equipment Ground Bar<br />

▪ Ground Bar Brazed to Box<br />

Circuit Breaker Accessories<br />

Handle Blocking Device<br />

Blocks handle in either the<br />

“ON” or “OFF” position.<br />

Padlocking Device – Padlocks<br />

in “OFF” position.<br />

Available in 90” high enclosure only. Unit space is 42<br />

1/2” with Test and Monitor Panel; 45” without Test and<br />

Monitor Panel.<br />

Not available on Sensitrip III.<br />

For required unit space, consult local sales office.<br />

Shunt Trip on 100A frame breakers increases mounting<br />

height to 6.25” for twin mounting.<br />

The 600A, 100% rated breaker requires the use of an<br />

800A frame breaker.<br />

11-78<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category PBSB


Panelboards<br />

Embedded Micro Metering Module<br />

Revised on 04/30/19<br />

Selection<br />

SEM3 System configured in Panelboards<br />

The Siemens SEM3 system can be configured for factory<br />

installation in branch circuit monitoring applications using the<br />

Siemens COMPAS configuration tool. This option can lower<br />

the installation time of the system for the installer while providing<br />

a factory warrantied solution.<br />

The SEM3 system can be factory installed in unit space in<br />

type P2, P4, & P5 Siemens panel boards. Please note P1 and<br />

P3 configurations are not available at this time and the amount<br />

of unit space needed varies depending upon the application.<br />

Please note that lead time adders will apply and may vary<br />

depending upon the configuration of the system.<br />

11 PANELBOARDS<br />

SEM3 for use in Siemens Panelboards<br />

Available in a NEMA 1, 3R, or 12 rated enclosure<br />

Controller<br />

SEM3 controller is mounted in unit space opposite of the feed location specified in COMPAS<br />

(i.e., bottom mount for top feed) and will require 3” of unit space. Each controller will be powered<br />

by direct tap connection to the panel section bus. Each controller can monitor up to 45<br />

circuits. Applications that require monitoring more than 45 circuits will require additional controllers.<br />

Current Transformers (CTs)<br />

Seven sizes of CTs are available for use in the P4 panel: 50, 125, 250, 400, 600, 800, 1200<br />

amp. All CTs are pre-mounted to a support bracket that attaches to the base rail of the interior<br />

of the panel board. Each bracket supports a maximum of 3 CTs and is designed for the breaker<br />

selected (brackets are not interchangeable between breaker frames). Each CT will be attached<br />

to a data module that is placed in the meter racks.<br />

Meter Racks<br />

Each meter rack requires 3” of unit space. All meter racks will be installed next to the SEM3<br />

controller in unit space. The COMPAS configuration tool will select the appropriate meter rack<br />

configuration according to the user’s application and will use the 21 space meter rack as a<br />

default option where possible. Only one meter rack (regardless of number of positions) can be<br />

installed in 3” of unit space.<br />

NOTE: Monitoring of 45 circuits will require 9" of unit space: two 21 position racks and one 3<br />

position rack<br />

Other Considerations<br />

Configuration: Data modules from CTs monitoring a circuit breaker must be mounted adjacent<br />

to one another in the meter rack. Any field changes to the factory configuration must take<br />

this into account.<br />

Start-up & Commissioning: Siemens can provide these services. Contact your local<br />

SIEMENS PDS Power Solutions Business Developer for more details.<br />

Billing Services for sub billing applications: Billing services are available. Contact your local<br />

SIEMENS PDS Power Solutions Business Developer for more details.<br />

Product Category PBSB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-79


Panelboards<br />

Embedded Micro Metering Module<br />

Revised on 04/30/19<br />

Selection<br />

11<br />

PANELBOARDS<br />

P4 Devices<br />

Enclosure sizes<br />

Example P4 Panel with SEM3 Type 1 Enclosure<br />

P4 = (32" Wide x 10" Deep)<br />

Enclosure heights are in 15" increments from 60" thru 90".<br />

Enclosure heights: 60", 75", 90" (there are optional depths also)<br />

The COMPAS configuration tool can provide actual dimensions<br />

based on the configuration. Example below is largest standard<br />

P4 enclosure for factory assembled panel - unit space is in 3.75"<br />

increments - up to 6 circuits can occupy each 3.75" of unit space.<br />

32" std. width for P4<br />

Main Breaker / Main Lug space<br />

varies based on selected options<br />

Unit space varies<br />

based on selected options<br />

Note: All circuits do not have to be monitored<br />

by SEM3 - user can select any circuits in this<br />

space to be monitored.<br />

Based on smallest branch breakers and a 3-phase main<br />

being monitored. There is a maximum of 63 circuits that can<br />

be monitored with the configuration shown. Some<br />

selections of main breakers and other subfeed options could<br />

limit this further.<br />

In this situation there is 37.5" of unit space available -<br />

so 60 branch circuits could be monitored.<br />

If monitoring the main three additional circuits could<br />

be monitored with a total of 63 circuits.<br />

This requires two controllers and three 21 position<br />

racks using 18.75" of unit space.<br />

- see below -<br />

SEM3 space varies by number of circuits<br />

monitored - this uses unit space.<br />

== > 7.5" of space for up to 21 circuits monitored<br />

one controller and one 21-pos rack<br />

== > 11.25" of space for up to 42 circuits monitored<br />

one controller and two 21-pos racks<br />

== > 15" of space for up to 45 circuits monitored<br />

one controller and two 21-pos racks plus one 3-pos rack<br />

== > 18.75" of space for up to 63 circuits monitored<br />

two controllers and three 21-pos racks<br />

Note: If subfeed space is needed - it will take<br />

away from available unit space.<br />

Due to gutter space limitations, SEM3 is not available in a P4 Powerpanel for 3VA52, 3VA61, or 3VA62 breakers.<br />

11-80<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Panelboards<br />

Modifications and Additions<br />

Selection<br />

Lug Modifications<br />

Compression Lugs<br />

Style<br />

Amp<br />

Rating Breaker Type Compression Connectors Available Unit Space Reduction<br />

400 N/A All compression lugs<br />

600 N/A All compression lugs<br />

MLO<br />

800 N/A All compression lugs<br />

Deduct 5.0” of Unit Space<br />

1000 N/A All compression lugs<br />

1200 N/A All compression lugs<br />

JD6, JXD6, HJD6, HJXD6,<br />

Main Breaker 400<br />

HHJD6, HHJXD6, CJD6,<br />

(2)#2/0 AWG - 500 Kcmil Cu or Al<br />

SJD6, SHJD6, SCJD6<br />

LD6, LXD6, HLD6, HLXD6,<br />

Deduct 0” of Unit Space<br />

NL, HL, LL<br />

(1)#6 - 350 Kcmil Cu or Al<br />

HHLD6, HHLXD6, CLD6,<br />

(2)#2/0 AWG - 500 Kcmil Cu or Al<br />

Main Breaker 600 SLD6, SHLD6, SCLD6<br />

Deduct 0” of Unit Space<br />

NJ, HJ, LJ<br />

(2)#6 - 350 Kcmil Cu or Al<br />

11 PANELBOARDS<br />

Alternate Lugs<br />

Amp<br />

Rating<br />

400 N/A<br />

Breaker<br />

Type Compression Connectors Available Unit Space Reduction<br />

(1)#3/0 AWG - 750 Kcmil or<br />

(2)#3/0 AWG 250 Kcmil Cu or Al<br />

Deduct 0” of Unit Space<br />

600 N/A (2)#3/0 AWG - 750 Kcmil Deduct 5” of Unit Space<br />

800 N/A (3)#3/0 AWG - 750 Kcmil Cu or Al Deduct 10” of Unit Space<br />

1200 N/A<br />

(4)#3/0 AWG - 600 Kcmil Cu or Al<br />

(4)#3/0 AWG - 750 Kcmil Cu or Al<br />

Deduct 10” of Unit Space<br />

Product Category PBSB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-81


Panelboards<br />

Kits and Accessories<br />

Selection<br />

11<br />

PANELBOARDS<br />

P4 Enclosures<br />

Description<br />

P4 Type 1 32” W x 10” D x 60” H<br />

P4 Type 1 32” W x 10” D x 75” H<br />

P4 Type 1 32” W x 10” D x 90” H<br />

P4 Type 3R/12 60” H<br />

P4 Type 3R/12 75” H<br />

P4 Type 3R/12 90” H<br />

Catalog number<br />

PB60<br />

PB75<br />

PB90<br />

WP260<br />

WP275<br />

WP290<br />

P4 Trims<br />

Description<br />

P4 Std (4 piece trim) vented 60”<br />

P4 Std (4 piece trim) vented 75”<br />

P4 Std (4 piece trim) vented 90”<br />

P4 VBS Std (4 Piece trim) vented 60”<br />

P4 VBS Std (4 Piece trim) vented 75”<br />

P4 VBS Std (4 Piece trim) vented 90”<br />

P4 Std (4 piece trim) unvented 60”<br />

P4 Std (4 piece trim) unvented 75”<br />

P4 Std (4 piece trim) unvented 90”<br />

P4 VBS Std (4 Piece trim) unvented 60”<br />

P4 VBS Std (4 Piece trim) unvented 75”<br />

P4 VBS Std (4 Piece trim) unvented 90”<br />

P4 Std (4 piece trim) vented 60” with hinged gutter covers<br />

P4 Std (4 piece trim) vented 75” with hinged gutter covers<br />

P4 Std (4 piece trim) vented 90” with hinged gutter covers<br />

P4 VBS Std (4 piece trim) vented 60” w/Hinged gutter covers<br />

P4 VBS Std (4 piece trim) vented 60” w/Hinged gutter covers<br />

P4 VBS Std (4 piece trim) vented 60” w/Hinged gutter covers<br />

P4 Std (4 piece trim) unvented 60” with hinged gutter covers<br />

P4 Std (4 piece trim) unvented 75” with hinged gutter covers<br />

P4 Std (4 piece trim) unvented 90” with hinged gutter covers<br />

P4 VBS Std (4 piece trim) unvented 60” w/Hinged gutter covers<br />

P4 VBS Std (4 piece trim) unvented 60” w/Hinged gutter covers<br />

P4 VBS Std (4 piece trim) unvented 60” w/Hinged gutter covers<br />

P4 Std (1 PC Door) vented 60”<br />

P4 Std (1 PC Door) vented 75”<br />

P4 Std (1 PC Door) vented 90”<br />

P4 Std (1 PC Door) unvented 60”<br />

P4 Std (1 PC Door) unvented 75”<br />

P4 Std (1 PC Door) unvented 90”<br />

P4 Std (1 PC Door-in-door) vented 60”<br />

P4 Std (1 PC Door-in-door) vented 75”<br />

P4 Std (1 PC Door-in-door) vented 90”<br />

P4 Std (1 PC Door-in-door) unvented 60”<br />

P4 Std (1 PC Door-in-door) unvented 75”<br />

P4 Std (1 PC Door-in-door) unvented 90”<br />

Catalog number<br />

P460V<br />

P475V<br />

P490V<br />

P460VV<br />

P475VV<br />

P490VV<br />

P460NV<br />

P475NV<br />

P490NV<br />

P460NVV<br />

P475NVV<br />

P490NVV<br />

P460VHG<br />

P475VHG<br />

P490VHG<br />

P460VVHG<br />

P475VVHG<br />

P490VVHG<br />

P460NVHG<br />

P475NVHG<br />

P490NVHG<br />

P460NVVHG<br />

P475NVVHG<br />

P490NVVHG<br />

P460VD<br />

P475VD<br />

P490VD<br />

P460NVD<br />

P475NVD<br />

P490NVD<br />

P460VDD<br />

P475VDD<br />

P490VDD<br />

P460NVDD<br />

P475NVDD<br />

P490NVDD<br />

P4 Flush mounting kits<br />

Description<br />

Flush kit for P4 60” High<br />

Flush kit for P4 75” High<br />

Flush kit for P4 90” High<br />

Catalog number<br />

F60<br />

F75<br />

F90<br />

11-82<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category PBSB


Panelboards<br />

Type P4 Panelboards<br />

Revised on 04/30/19<br />

Dimensions<br />

Type 1 Box<br />

Box is symmetrical<br />

8.0 in.<br />

[ 203 ]<br />

Recommended Conduit Area<br />

4.37 in.<br />

[ 111 ]<br />

6.63 in.<br />

[ 168 ]<br />

4.37 in.<br />

[ 111 ]<br />

6.63 in.<br />

[ 168 ]<br />

0.31 in.<br />

[ 8 ]<br />

Mounting<br />

dimple<br />

0.31 in.<br />

[ 8 ]<br />

Mounting<br />

dimple<br />

11 PANELBOARDS<br />

30.0 in.<br />

[ 254 ]<br />

6.63 in.<br />

[ 168 ]<br />

6.63 in.<br />

[ 168 ]<br />

14.04 in.<br />

[ 357 ]<br />

14.04 in.<br />

[ 357 ]<br />

4.37 in.<br />

[ 111 ]<br />

4.37 in.<br />

[ 111 ]<br />

Type 3R and 3R/12 Box<br />

0.5 in.<br />

[ 127 ]<br />

0.5 in.<br />

[ 127 ]<br />

16.08 in. [ 408 16.08 ] in. [ 408 ]<br />

(Mounting Holes (Mounting Holes<br />

0.44 in. Square) 0.44 in. Square)<br />

(Mounting Holes (Mounting Holes<br />

0.44 in. Square) 0.44 in. Square)<br />

0.83 in.<br />

[ 21 ]<br />

0.83 in.<br />

[ 21 ]<br />

(Mounting Holes (Mounting Holes<br />

0.44 in. Square) 0.44 in. Square)<br />

(Mounting Holes (Mounting Holes<br />

0.44 in. Square) 0.44 in. Square)<br />

16.0 in. [ 40616.0 ] in. [ 406 ]<br />

32.4 in.<br />

[ 823 ]<br />

32.4 in.<br />

[ 823 ]<br />

0.93 in.<br />

[ 24 ]<br />

0.93 in.<br />

[ 24 ]<br />

10.39 in.<br />

[ 264 ]<br />

10.39 in.<br />

[ 264 ]<br />

Dimensions shown in inches and millimeters [ ].<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-83


Panelboards<br />

Type P5 Panelboards<br />

Revised on 05/15/18<br />

General<br />

11<br />

PANELBOARDS<br />

Features<br />

The P5 is the largest distribution panel<br />

in the Siemens’ panel family. Even with<br />

a larger footprint, the P5 is still a space<br />

saver with its 38” width and 12.75”<br />

depth. The panel offers higher main<br />

ratings to fit applications that require<br />

larger branch devices.<br />

This panel offers a wide array of factory<br />

assembled options and has the ability<br />

to mix breaker frames in unit space up<br />

to 1200 amps and fusible switches up<br />

to 1200 amps. Bussing options for the<br />

P5 vary from the standard temperature<br />

rated aluminum to temperature rated<br />

copper and 750 A/SI aluminum and<br />

1000A/SI copper designs. All aluminum<br />

bussing in the P5 panel is tin-plated<br />

as a standard. Silver-plated is offered<br />

as the default for copper bus and tin<br />

as an option. Integrated time clocks,<br />

bus mounted contactors as mains or<br />

submains, split bus and subfeed lugs<br />

(up to 600 amps) are just a few of the<br />

options of this flexible panel.<br />

The P5 panel configurations defined by<br />

the unit space allowed for a given<br />

amperage, main device and box height.<br />

The P5 panel starts with a 60" high box.<br />

All of the branch devices are unit space<br />

mounted. Breakers and switches can be<br />

mixed and matched to meet customer<br />

requirements.<br />

Main Lug / Main Breaker / Main<br />

Switch<br />

Enclosure – Standard Type 1 enclosure<br />

is 38" wide x 12.75" deep. X Box Height<br />

is determined by main device and unit<br />

space. See charts for box height.<br />

Voltage – 600V AC max.<br />

250V DC max.<br />

Amperage – 400-1200 amp main<br />

breaker, 400-1200 amp main lug only or<br />

200-1200 amp main switch.<br />

Short Circuit Rating – 200 Kaic max.<br />

symmetrical or equal to the lowest rated<br />

device installed unless a series rating is<br />

indicated. Panels with subfeed or<br />

feed-thru lugs without a main device,<br />

circuit breaker or fusible unit, are limited<br />

to a three-cycle rating. The three-cycle<br />

rating for the P5 panel is limited to 42<br />

Kaic. Note that the main device may be<br />

mounted remote from the panel.<br />

Bussing – The P5 panel has more<br />

options to meet market requirements.<br />

The standard bussing is temperature<br />

rated aluminum. The rating is per the<br />

requirements of UL 67 – the standard<br />

for panelboards. All aluminum bussing<br />

is tin-plated. Optional bussing for<br />

the P5 panel is: 750 A/SI aluminum,<br />

temperature rated copper, and<br />

1000 A/SI copper. The copper bus<br />

option for this panel is tin-plated.<br />

Weight – Approximate<br />

Total panelboard weight when filled<br />

with a normal quantity of breakers and<br />

accessories is about 10 lbs. (1 kg) per<br />

inch (54g per mm) of box height.<br />

Main Lugs a<br />

Ampere<br />

Connectors Suitable for<br />

Rating<br />

Copper or Aluminum<br />

400 (1) 250-500Kcmil<br />

600 (2) #3/0-500Kcmil<br />

800 (3) #3/0 AWG-500 Kcmil<br />

1000 (4) #3/0 AWG-500 Kcmil<br />

1200 (4) #3/0 AWB-500 Kcmil<br />

aAlternate lugs for 750 kcmil cable are available, but<br />

result in significant loss of branch unit mounting space.<br />

Consult Siemens.<br />

Gauge Steel of Boxes Fronts,<br />

Surface and Flush<br />

Dimensions in<br />

inches (mm) Gauge Steel<br />

Width Height Box Fronts<br />

38"<br />

(965)<br />

60 - 75 - 90<br />

(1524,1905,<br />

2286)<br />

60 - 75 - 90<br />

(1524,1905,<br />

2286)<br />

60 - 75 - 90<br />

(1524,1905,<br />

2286)<br />

#16 a #14 (1 piece trim)<br />

#14 (4 piece trim)<br />

#14 #12 (1 piece &<br />

door in door)<br />

#10 (1 piece &<br />

door in door)<br />

#14 #16 (4 piece, top<br />

and bottom over)<br />

#10 (4 piece, side/<br />

gutter cover)<br />

a 16 gauge side panels, 12 gauge back support, 14 gauge<br />

back panels.<br />

11-84<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Panelboards<br />

Power and Distribution<br />

Selection/Dimensions<br />

Enclosure Selection <br />

Enclosure Dimension in Inches (mm)<br />

Available Unit Space in Inches (mm)<br />

H W D Main Lug Only Main Breaker Main VB Switch<br />

Main HCP<br />

Switch<br />

Type 1 or 3R/12 Type 1 Type 3R/12 400 - 1200A 400-800A 1200A 200A 400A-600A 400-1200A<br />

60 (1524) 38 (965) 12.75 (324) 14.25 (362) 30 (762) 21.25 (540) 20 (508) 20 (508) - 13.75 (349)<br />

75 (1905) 38 (965) 12.75 (324) 14.25 (362) 45 (1143) 36.25 (921) 35 (889) 40 (1016) 25 (889) 28.75 (730)<br />

90 (2286) 38 (965) 12.75 (324) 14.25 (362) 60 (1524) 51.25 (1302) 50 (1270) 55 (1397) 40 (1270) 43.75 (1111)<br />

11 PANELBOARDS<br />

Main Breaker Unit Space Dimensions<br />

Ampere Breaker Breaker<br />

Dimensions in inches (mm)<br />

Rating Family Type<br />

A<br />

B<br />

Sentron JXD6, JD6, HJXD6, HJD6, HHJXD6, HHJD6 13.425 (265)<br />

VL<br />

400<br />

NJ, HJ, LJ 15.500 (318)<br />

SJD6, SHJD6 13.425 (265)<br />

Sentron<br />

CJD6, SCJD6 11.250 (210)<br />

Sentron LXD6, LD6, HLXD6, LD6, HHLXD6, HHLD6 13.425 (265)<br />

VL<br />

600<br />

NL, HL, LL 14.250 (286)<br />

SLD6, SHLD6 13.425 (265)<br />

Sentron<br />

CLD6, SCLD6 11.250 (210)<br />

13.125 (333)<br />

VL NM, HM, LM 13.425 (265)<br />

800<br />

MXD6, MD6, HMXD6, HMD6,<br />

13.00 (330)<br />

Sentron<br />

CMD6, SMD6, SHMD6, SCMD6<br />

10.42 (265<br />

VL NN, HN, LN 13.425 (265)<br />

1200<br />

Sentron<br />

NXD6, ND6, HNXD6, HND6,<br />

CND6, SND6, SHMD6, SCND6<br />

13.00 (330)<br />

13.00 (330)<br />

Main Switch<br />

Maximum<br />

Ampere Rating A B<br />

400A/600A VB 9.30 (236)<br />

800A/1200A HCP 10.30 (262) 13.125 (333)<br />

200A VB 13.425 (265)<br />

Main Switch Connectors<br />

Ampere<br />

Rating<br />

400<br />

Connectors suitable for<br />

Copper or Aluminum<br />

(1) #3/0 AWG-500 kcmil<br />

(2) #3/0 AWG-250 kcmil<br />

600 (2) #3/0 AWG-500 kcmil<br />

800 (3) #3/0 AWG-500 kcmil<br />

1200 (4) #3/0 AWG-500 kcmil<br />

Main Breaker Wire Bending Space<br />

Dimensions & Main Switch<br />

Main Lugs Only Wire Bending Space<br />

Lugs<br />

Dimensions in inches (mm)<br />

Main Lug<br />

400A<br />

A<br />

600A<br />

B<br />

800A<br />

C<br />

1000A<br />

D<br />

1200A<br />

E<br />

Neutral<br />

800A<br />

G<br />

Standard 16.500 (419) 16.750 (425) 15.969 (406) 15.969 (406) 15.969 (406) 13.125 (333)<br />

Oversize 16.500 (419) 21.750 (552) 25.969 (660) 25.969 (660) 25.969 (660) 23.125 (587)<br />

Crimp 19.187 (487) 18.250 (464) 18.687 (475) 18.250 (464) 18.250 (464) 15.937 (405)<br />

Standard with<br />

Subfeed<br />

16.750 (425) 15.969 (406) — — — 13.125 (333)<br />

Standard with<br />

Feed-thru<br />

16.500 (419) 16.750 (425) — — — 13.125 (333)<br />

Main Lugs Only Wire Bending Space<br />

a Standard trim is for space without door. Surface flush<br />

one piece trim is available for 32" (813mm) wide circuit<br />

breaker panel.<br />

Available with solid state (electronic) trip units only.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-85


Panelboards<br />

Power and Distribution<br />

Selection<br />

11<br />

PANELBOARDS<br />

Type P5<br />

Shown with Standard Mains, Top Fed and Surface Trim<br />

Catalog number is for aluminum main<br />

bus. For optional copper main bus<br />

change “A” in position 11 to “E” (silverplated<br />

copper bus).<br />

Main Lugs Only — shown with aluminum bus, top fed, and surface trims.<br />

Maximum Unit<br />

208Y/120V 240/120V 120/240V or 250 Vdc Max<br />

Panel<br />

Ampere Rating<br />

Space<br />

(inches)<br />

3-Phase, 4-Wire<br />

Catalog Number<br />

3-Phase, 4-Wire<br />

Catalog Number<br />

1-Phase, 3-Wire<br />

Catalog Number<br />

800 b 45 P5C75ML800ATS P5B75ML800ATS P5A75ML800ATS<br />

30 P5C60ML800ATS P5B60ML800ATS P5A60ML800ATS<br />

60 P5C90ML800ATS P5B90ML800ATS P5A90ML800ATS<br />

30 P5C60ML101ATS P5B60ML101ATS P5A60ML101ATS<br />

1000<br />

45 P5C75ML101ATS P5B75ML101ATS P5A75ML101ATS<br />

60 P5C90ML101ATS P5B90ML101ATS P5A90ML101ATS<br />

30 P5C60ML120ATS P5B60ML120ATS P5A60ML120ATS<br />

1200<br />

45 P5C75ML120ATS P5B75ML120ATS P5A75ML120ATS<br />

60 P5C90ML120ATS P5B90ML120ATS P5A90ML120ATS<br />

Maximum<br />

Panel<br />

Ampere Rating<br />

Unit<br />

Space<br />

(inches)<br />

240 480Y/277V 480V a<br />

3-Phase, 3-Wire<br />

Catalog Number<br />

Panels are top feed, surface mounted.<br />

For bottom feed, change “T” in position<br />

12 to “B”. For flush mounting,<br />

change “S” in position 13 to “F”.<br />

3-Phase, 4-Wire<br />

Catalog Number<br />

1-Phase, 3-Wire<br />

Catalog Number<br />

800 b 45 P5D75ML800ATS P5E75ML800ATS P5F75ML800ATS<br />

30 P5D60ML800ATS P5E60ML800ATS P5F60ML800ATS<br />

60 P5D90ML800ATS P5E90ML800ATS P5F90ML800ATS<br />

30 P5D60ML101ATS P5E60ML101ATS P5F60ML101ATS<br />

1000<br />

45 P5D75ML101ATS P5E75ML101ATS P5F75ML101ATS<br />

60 P5D90ML101ATS P5E90ML101ATS P5F90ML101ATS<br />

30 P5D60ML120ATS P5E60ML120ATS P5F60ML120ATS<br />

1200<br />

45 P5D75ML120ATS P5E75ML120ATS P5F75ML120ATS<br />

60 P5D90ML120ATS P5E90ML120ATS P5F90ML120ATS<br />

Replace fifth and sixth position<br />

in panelboard catalog number,<br />

with alternate main breaker code.<br />

Use price adders from main breaker<br />

section table. Horizontally mounted.<br />

Main Circuit Breaker — shown with aluminum bus, top fed, and surface trims.<br />

Maximum Unit<br />

208Y/120V 240/120V 120/240V or 250 Vdc Max<br />

Panel<br />

Ampere Rating<br />

Space<br />

(inches)<br />

3-Phase, 4-Wire<br />

Catalog Number<br />

3-Phase, 4-Wire<br />

Catalog Number<br />

1-Phase, 3-Wire<br />

Catalog Number<br />

800 b 36.25 P5C75M1800ATS P5B75M1800ATS P5A75M1800ATS<br />

21.25 P5C60M1800ATS P5B60M1800ATS P5A60M1800ATS<br />

51.25 P5C90M1800ATS P5B90M1800ATS P5A90M1800ATS<br />

20 P5C60N1120ATS P5B60N1120ATS P5A60N1120ATS<br />

1200<br />

35 P5C75N1120ATS P5B75N1120ATS P5A75N1120ATS<br />

50 P5C90N1120ATS P5B90N1120ATS P5A90N1120ATS<br />

Maximum<br />

Panel<br />

Ampere Rating<br />

Unit<br />

Space<br />

(inches)<br />

240 480Y/277V 480V a<br />

3-Phase, 4-Wire<br />

Catalog Number<br />

3-Phase, 4-Wire<br />

Catalog Number<br />

1-Phase, 3-Wire<br />

Catalog Number<br />

800 b 36.25 P5D75M1800ATS P5E75M1800ATS P5F75M1800ATS<br />

21.25 P5D60M1800ATS P5E60M1800ATS P5F60M1800ATS<br />

51.25 P5D90M1800ATS P5E90M1800ATS P5F90M1800ATS<br />

20 P5D60N1120ATS P5E60N1120ATS P5F60N1120ATS<br />

1200<br />

35 P5D75N1120ATS P5E75N1120ATS P5F75N1120ATS<br />

50 P5D90N1120ATS P5E90N1120ATS P5F90N1120ATS<br />

For inches / millimeters conversion,<br />

see Application Data section.<br />

a For 600V, change “F” in position 3 to “G”. Price only<br />

branch breakers with 600V ratings.<br />

b Alternate main breaker requires additional 1.25" unit space.<br />

11-86<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category PBSB


Panelboards<br />

Power and Distribution<br />

Revised on 04/30/19<br />

Selection<br />

Main Fusible Switch (fuses not included)<br />

Maximum Unit 208Y/120V 240/120V 120/240V 240V 480Y/277V 480V a<br />

Panel<br />

Ampere Rating<br />

Space<br />

(inches)<br />

3-Phase, 4-Wire<br />

Catalog Number<br />

3-Phase, 4-Wire<br />

Catalog Number<br />

1-Phase, 3-Wire<br />

Catalog Number<br />

3-Phase, 3-Wire<br />

Catalog Number<br />

3-Phase, 4-Wire<br />

Catalog Number<br />

3-Phase, 3-Wire<br />

Catalog Number<br />

400<br />

25 P5C75MS400ATS P5B75MS400ATS P5A75MS400ATS P5D75MS400ATS P5E75MS400ATS P5F75MS400ATS<br />

40 P5C90MS400ATS P5B90MS400ATS P5A90MS400ATS P5D90MS400ATS P5E90MS400ATS P5F90MS400ATS<br />

600<br />

25 P5C75MS600ATS P5B75MS600ATS P5A75MS600ATS P5D75MS600ATS P5E75MS600ATS P5F75MS600ATS<br />

40 P5C90MS600ATS P5B90MS600ATS P5A90MS600ATS P5D90MS600ATS P5E90MS600ATS P5F90MS600ATS<br />

28.75<br />

800 d P5C75MS800ATS P5B75MS800ATS P5A75MS800ATS P5D75MS800ATS P5E75MS800ATS P5F75MS800ATS<br />

43.75 P5C90MS800ATS P5B90MS800ATS P5A90MS800ATS P5D90MS800ATS P5E90MS800ATS P5F90MS800ATS<br />

28.75<br />

1200 d P5C75MS120ATS P5B75MS120ATS P5A75MS120ATS P5D75MS120ATS P5E75MS120ATS P5F75MS120ATS<br />

43.75 P5C90MS120ATS P5B90MS120ATS P5A90MS120ATS P5D90MS120ATS P5E90MS120ATS P5F90MS120ATS<br />

11 PANELBOARDS<br />

Alternate Main Breaker Selection b<br />

Breaker<br />

Frame<br />

Rating<br />

400<br />

600<br />

800<br />

1200<br />

Trip<br />

Type<br />

Thermal<br />

Magnetic<br />

Electronic<br />

(Solid state)<br />

Thermal<br />

Magnetic<br />

Electronic<br />

(Solid state)<br />

Thermal<br />

Magnetic<br />

Electronic<br />

(Solid state)<br />

Thermal<br />

Magnetic<br />

Electronic<br />

(Solid state)<br />

For inches / millimeters conversion,<br />

see Application Data section.<br />

Breaker<br />

Family<br />

Sentron<br />

VL<br />

Sentron<br />

Sentron<br />

VL<br />

Sentron<br />

VL<br />

Sentron<br />

VL<br />

Sentron<br />

VL<br />

Sentron<br />

VL<br />

Sentron<br />

a For 600V, change “F” in position 3 to “G”. Price only<br />

branch breakers with 600V ratings.<br />

b For ground fault, see page 11-92.<br />

Unit Space<br />

Requirements<br />

in Inches<br />

Maximum Interruption Rating<br />

(KAIC) Volts AC<br />

Frame<br />

Type<br />

Type Ref.<br />

Code <br />

Trip<br />

Amperage<br />

240 480 600<br />

JXD6 JX 200, 225, 250, 300, 350, 400 8.75 65,000 35,000 25,000<br />

JD6 J6 200, 225, 250, 300, 350, 400 8.75 65,000 35,000 25,000<br />

HJXD6 H5 200, 225, 250, 300, 350, 400 8.75 100,000 65,000 35,000<br />

HJD6 H6 200, 225, 250, 300, 350, 400 8.75 100,000 65,000 35,000<br />

HHJXD6 H9 200, 225, 250, 300, 350, 400 8.75 200,000 100,000 50,000<br />

HHJD6 6H 200, 225, 250, 300, 350, 400 8.75 200,000 100,000 50,000<br />

CJD6 CJ 200, 225, 250, 300, 350, 400 8.75 200,000 150,000 100,000<br />

NJ J1 250, 400 6.25 65,000 35,000 25,000<br />

HJ J7 250, 400 6.25 100,000 65,000 25,000<br />

LJ J3 250, 400 6.25 200,000 100,000 25,000<br />

SJD6 SJ 200, 300, 400 8.75 65,000 35,000 25,000<br />

SHJD6 SX 200, 300, 400 8.75 100,000 65,000 35,000<br />

SCJD6 SC 200, 300, 400 8.75 200,000 150,000 100,000<br />

LXD6 LX 450, 500, 600 8.75 65,000 35,000 25,000<br />

LD6 L6 250, 300, 350, 400, 450, 500, 600 8.75 65,000 35,000 25,000<br />

HLXD6 HO 250, 300, 350, 400, 450, 500, 600 8.75 100,000 65,000 35,000<br />

HLD6 HL 250, 300, 350, 400, 450, 500, 600 8.75 100,000 65,000 35,000<br />

HHLXD6 XH 250, 300, 350, 400, 450, 500, 600 8.75 200,000 100,000 50,000<br />

HHLD6 HH 250, 300, 350, 400, 450, 500, 600 8.75 200,000 100,000 50,000<br />

CLD6 CL 250, 300, 350, 400, 450, 500, 600 8.75 200,000 150,000 100,000<br />

NL L7 400, 600 6.25 65,000 35,000 25,000<br />

HL L2 400, 600 6.25 100,000 65,000 25,000<br />

LL SL 400, 600 6.25 200,000 100,000 25,000<br />

SLD6 L6 300, 400, 500, 600 8.75 65,000 35,000 25,000<br />

SHLD6 S2 300, 400, 500, 600 8.75 100,000 65,000 35,000<br />

SCLD6 SI 300, 400, 500, 600 8.75 200,000 150,000 100,000<br />

NM M1 600, 700, 800 8.75 65,000 35,000 25,000<br />

HM M2 600, 700, 800 8.75 100,000 65,000 35,000<br />

LM M3 600, 700, 800 8.75 200,000 100,000 50,000<br />

LMXD6 LM 500, 600, 700, 800 8.75 65,000 50,000 25,000<br />

LMD6 L1 500, 600, 700, 800 8.75 65,000 50,000 25,000<br />

HLMXD6 HK 500, 600, 700, 800 8.75 100,000 65,000 50,000<br />

HLMD6 HJ 500, 600, 700, 800 8.75 100,000 65,000 50,000<br />

MXD6 MX 500, 600, 700, 800 10.00 65,000 50,000 25,000<br />

MD6 MD 500, 600, 700, 800 10.00 65,000 50,000 25,000<br />

HMXD6 HR 500, 600, 700, 800 10.00 100,000 65,000 50,000<br />

HMD6 HM 500, 600, 700, 800 10.00 100,000 65,000 50,000<br />

CMD6 CM 500, 600, 700, 800 10.00 200,000 100,000 65,000<br />

NM M1 600, 800 8.75 65,000 35,000 25,000<br />

HM M2 600, 800 8.75 100,000 65,000 35,000<br />

LM M3 600, 800 8.75 200,000 100,000 50,000<br />

SMD6 SM 600, 700, 800 10.00 65,000 50,000 25,000<br />

SHMD6 S5 600, 700, 800 10.00 100,000 65,000 50,000<br />

SCMD6 SO 600, 700, 800 10.00 200,000 100,000 65,000<br />

NN N1 800, 900, 1000, 1200 10.00 65,000 35,000 25,000<br />

HN N2 800, 900, 1000, 1200 10.00 100,000 65,000 35,000<br />

LN N3 800, 900, 1000, 1200 10.00 200,000 100,000 65,000<br />

NXD6 NX 900, 1000, 1200 10.00 65,000 50,000 25,000<br />

ND6 ND 900, 1000, 1200 10.00 65,000 50,000 25,000<br />

HNXD6 HT 900, 1000, 1200 10.00 100,000 65,000 50,000<br />

HND6 HN 900, 1000, 1200 10.00 100,000 65,000 50,000<br />

CND6 Cn 900, 1000, 1200 10.00 200,000 100,000 65,000<br />

NN N1 800, 1000, 1200 10.00 65,000 35,000 25,000<br />

HN N2 800, 1000, 1200 10.00 100,000 65,000 35,000<br />

LN N3 800, 1000, 1200 10.00 200,000 100,000 65,000<br />

SND6 SN 800, 1000, 1200 10.00 65,000 50,000 25,000<br />

SHND6 AD 800, 1000, 1200 10.00 100,000 65,000 50,000<br />

SCND6 SR 800, 1000, 1200 10.00 200,000 100,000 65,000<br />

c Replace “MS” in catalog number with code letter.<br />

(See Main Fusible Switch Table above)<br />

d 800 and 1200 ampere switches have “L” class fuse<br />

provisions (Type HCP).<br />

Product Category PBSB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-87


Panelboards<br />

Power and Distribution<br />

Revised on 04/30/19<br />

Selection<br />

11<br />

PANELBOARDS<br />

P5 Branch Circuit Breakers<br />

Amp<br />

Rating<br />

100<br />

xx<br />

125<br />

150<br />

225<br />

250<br />

Trip<br />

Type<br />

Thermal<br />

Magnetic<br />

Breaker<br />

Family<br />

BL<br />

Special BLG<br />

Application BL<br />

Thermal<br />

Magnetic<br />

BQD<br />

Electronic<br />

and misc.<br />

Thermal<br />

Magnetic<br />

Electronic<br />

(Solid<br />

state)<br />

Electronic<br />

(Solid<br />

state)<br />

Thermal<br />

Magnetic<br />

Thermal<br />

Magnetic<br />

Electronic<br />

(Solid<br />

state)<br />

Thermal<br />

Magnetic<br />

Electronic<br />

(Solid<br />

state)<br />

BL<br />

GB<br />

Sentron<br />

GB2<br />

3VA41 c<br />

VL<br />

3VA61 c<br />

(ETU350 LSI<br />

standard)<br />

QR<br />

Sentron<br />

VL<br />

3VA52 c<br />

(W/TM230<br />

trip)<br />

3VA62 c<br />

(ETU350 LSI<br />

standard)<br />

Breaker<br />

Type<br />

1-Pole<br />

Max IR (kA) at<br />

120V 277V 347V<br />

125V<br />

DC<br />

Amp<br />

Ratings<br />

Avail.<br />

2-Pole and 3-Pole<br />

Max IR (kA) at<br />

120/<br />

240V<br />

240V<br />

480Y/<br />

277V<br />

480V<br />

600Y/<br />

347V<br />

600V<br />

125/<br />

250V<br />

DC<br />

250V<br />

DC<br />

Amp<br />

Ratings<br />

Avail.<br />

S = Single Mount<br />

S<br />

T = Twin mount<br />

T<br />

Unit Max<br />

Space 1-pole<br />

per Kit Circuits<br />

(in.) per Kit<br />

BL 10 — — — 15-70 10 10 — — — — — — 15-100 d — T 3.75 e 6<br />

BLH 22 — — — 15-70 22 22 — — — — — — 15-100 d — T 3.75 e 6<br />

HBL 65 — — — 15-50 65 65 — — — — — — 15-100 — T 3.75 e 6<br />

BLG a 10 — — — 15-20 10 — — — — — — — 30 — T 3.75 e 6<br />

BL (HID) 10 — — — 15-30 10 — — — — — — — 15-30 — T 3.75 e 6<br />

BQD f 65 14 — 14 15-100 — 65 14 — — — 14 — 15-100 — T 3.75 e 6<br />

BQD6 g 65 — — 14 15-70 — 65 — 10 — 14 — 15-70 — T 3.75 e 6<br />

AFCI/<br />

GFCI<br />

& Dual<br />

Function<br />

x — — —<br />

see<br />

special<br />

table<br />

page<br />

11-13<br />

x — — — — — — —<br />

see<br />

special<br />

table<br />

page<br />

11-13<br />

— T 3.75 e 6<br />

NGB 100 25 14 14 15-125 — 100 25 — 14 — 14 — 15-125 — T 3.75 e 6<br />

HGB 100 35 14 14 15-125 — 100 35 — 14 — 14 — 15-125 — T 3.75 e 6<br />

LGB 100 65 14 14 15-125 — 100 65 — 14 — 14 — 15-125 — T 3.75 e 6<br />

ED4 — 22 — 30 15-100 — 65 — 18 — — — 30 15-125 — T 3.75 e 6<br />

ED6 — — — — — — 65 — 25 — 18 — 30 20-125 — T 3.75 e 6<br />

HED4 b — — — — — — 65 — 42 — 18 — 30 15-125 — T 3.75 e 6<br />

HHED6 — — — — — — 100 — 65 — 18 — — 15-50 — T 3.75 e 6<br />

NGB2 100 25 14 14 d 15-125 — 100 — 25 14 — 14 d — 15-125 — T 3.75 e 6<br />

HGB2 100 35 22 14 d 15-125 — 100 — 35 22 — 14 d — 15-125 — T 3.75 e 6<br />

LGB2 100 65 25 14 d 15-125 — 100 — 65 25 — 14 d — 15-125 — T 3.75 e 6<br />

info not x x x x x x x — x — — x 6<br />

yet available<br />

x x x x x x x — x — — x 6<br />

x x x x x x x — x — — x 6<br />

ND — — — — — — 65 — 35 18 — — — 60-150 — T 5.00 6<br />

HD — — — — — — 100 — 65 20 — — — 60-150 — T 5.00 6<br />

LD — — — — — — 200 — 100 25 — — — 60-150 — T 5.00 6<br />

MDAE — — — — — 100 35 35 18 18 — — 40-150 — T 5.00 6<br />

HDAE — — — — — 100 65 65 22 22 — — 40-150 — T 5.00 6<br />

CDAE — — — — — 200 100 100 35 35 — — 40-150 — T 5.00 6<br />

LDAE — — — — — 200 150 150 50 50 — — 40-150 — T 5.00 6<br />

QR2 — — — — — — 10 — — — — — — 100-225 — T 5.00 6<br />

QRH2 — — — — — — 25 — — — — — — 100-225 — T 5.00 6<br />

HQR2 — — — — — — 65 — — — — — — 100-225 — T 5.00 6<br />

HQR2H — — — — — — 100 — — — — — — 100-225 — T 5.00 6<br />

FXD6-A, — — — — — — 65 — 35 — 22 — 30 70-250 S T 5.00 3 or 6<br />

FD6-A<br />

HFXD6, — — — — — — 100 — 65 — 25 — 30 70-250 S T 5.00 3 or 6<br />

HFD6<br />

HHFXD6, — — — — — — 200 — 100 — 25 — — 70-250 S — 5.00 3<br />

HHFD6<br />

CFD6-A — — — — — — 200 — 200 — 100 — 30 70-250 S — 5.00 3<br />

NF — — — — — — 65 — 35 — 18 — — 100-250 — T 5.00 6<br />

HF — — — — — — 100 — 65 — 20 — — 100-250 — T 5.00 6<br />

LF — — — — — — 200 — 100 — 25 — — 100-250 — T 5.00 6<br />

MFAS — — — — — 85 85 — 35 — 18 — 50 100-250 — T 5.00 6<br />

HFAS — — — — — 100 100 — 65 — 25 — 85 100-250 — T 5.00 6<br />

CFAS — — — — — 200 200 — 100 — 35 — 100 100-250 — T 5.00 6<br />

MFAE — — — — — — 100 35 35 18 — — — 100-250 — T 5.00 6<br />

HFAE — — — — — — 100 65 65 22 — — — 100-250 — T 5.00 6<br />

CFAE — — — — — — 200 100 100 35 — — — 100-250 — T 5.00 6<br />

LFAE — — — — — — 200 150 150 50 — — — 100-250 — T 5.00 6<br />

a BLG two-pole breaker is one phase and neutral. Three<br />

pole is two phases and neutral - See SpeedFax page 7-31<br />

b 1-pole HED 15-30A rated 65kA; 35-100A rated 25kA: 3-pole<br />

HED rated 42kA<br />

c Availability and additional specs tbd, expected late 2019.<br />

(COMPAS may allow selection of alternate trip units)<br />

d 2-pole only or two outer poles of 3-pole breaker<br />

e Accessories such as shunt trips on 3 pole breakers<br />

require 6.25" of unit space<br />

f Approved for CSA and UL Listed.<br />

g Approved for CSA but not UL Listed.<br />

11-88<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Panelboards<br />

Power and Distribution<br />

Revised on 04/30/19<br />

Selection<br />

P5 Branch Circuit Breakers<br />

cont.<br />

Amp<br />

Rating<br />

400<br />

600<br />

800<br />

1200<br />

Trip<br />

Type<br />

Thermal<br />

Magnetic<br />

Electronic<br />

(Solid<br />

state)<br />

Thermal<br />

Magnetic<br />

Electronic<br />

(Solid<br />

state)<br />

Thermal<br />

Magnetic<br />

Electronic<br />

(Solid<br />

state)<br />

Thermal<br />

Magnetic<br />

Electronic<br />

(Solid<br />

state)<br />

Breaker<br />

Family<br />

Sentron<br />

Breaker<br />

Type<br />

JXD6-A,<br />

JD6-A<br />

HJXD6-A,<br />

HJD6-A<br />

HHJXD6,<br />

HHJD6<br />

1-Pole<br />

Max IR (kA) at<br />

2-Pole and 3-Pole<br />

Max IR (kA) at<br />

S = Single Mount<br />

T = Twin mount<br />

Unit Max<br />

Space<br />

per Kit<br />

(in.)<br />

Amp<br />

125/ Amp<br />

1-pole<br />

125V Ratings 120/ 480Y/ 600Y/ 250V 250V Ratings<br />

Circuits<br />

120V 277V 347V DC Avail. 240V 240V 277V 480V 347V 600V DC DC Avail. S T<br />

per Kit<br />

— — — — — — 65 — 35 — 25 — 30 200-400 S T 8.75 3 or 6<br />

— — — — — — 100 — 65 — 35 — 30 200-400 S T 8.75 3 or 6<br />

— — — — — — 200 — 100 — 50 — — 200-400 S T 8.75 3 or 6<br />

CJD6-A — — — — — — 200 — 150 — 100 — 30 200-400 S — 8.75 3<br />

NJ — — — — — — 65 — 35 — 25 — — 250-400 S T 6.25 3 or 6<br />

VL HJ — — — — — — 100 — 65 — 25 — — 250-400 S T 6.25 3 or 6<br />

LJ — — — — — — 200 — 100 — 25 — — 250-400 S T 6.25 3 or 6<br />

SJD6-B — — — — — — 65 — 35 — 25 — — 200-400 S — 8.75 3<br />

Sentron SHJD6-B — — — — — — 100 — 65 — 35 — — 200-400 S — 8.75 3<br />

SCJD6-B — — — — — — 200 — 100 — 100 — — 200-400 S — 8.75 3<br />

LXD6 — — — — — — 65 — 35 — 25 — 30 450-600 S — 8.75 3<br />

LD6 — — — — — — 65 — 35 — 25 — 30 250-600 S — 8.75 3<br />

HLXD6, — — — — — — 100 — 65 — 35 — 30 250-600 S — 8.75 3<br />

Sentron HLD6<br />

HHLXD6, — — — — — — 200 — 100 — 50 — — 250-600 S — 8.75 3<br />

HHLD6<br />

CLD6 — — — — — — 200 — 150 — 100 — — 250-600 S — 8.75 3<br />

NL — — — — — — 65 — 35 — 18 — — 400-600 S — 6.25 3<br />

VL HL — — — — — — 100 — 65 — 18 — — 400-600 S — 6.25 3<br />

LL — — — — — — 200 — 100 — 18 — — 400-600 S — 6.25 3<br />

SLD6 — — — — — — 65 — 35 — 25 — — 300-600 S — 8.75 3<br />

Sentron SHLD6 — — — — — — 100 — 65 — 35 — — 300-600 S — 8.75 3<br />

SCLD6 — — — — — — 200 — 150 — 100 — — 300-600 S — 8.75 3<br />

NM — — — — — — 65 — 35 — 25 — 22 600-800 S — 8.75 3<br />

VL HM — — — — — — 100 — 65 — 35 — 25 600-800 S — 8.75 3<br />

LM — — — — — — 200 — 100 — 50 — 42 600-800 S — 8.75 3<br />

MXD6 — — — — — — 65 — 50 — 25 — 30 600-800 S — 10.00 3<br />

MD6 — — — — — — 65 — 50 — 25 — 30 500-800 S — 10.00 3<br />

Sentron HMXD6 — — — — — — 100 — 65 — 50 — 30 600-800 S — 10.00 3<br />

HMD6 — — — — — — 100 — 65 — 50 — 30 500-800 S — 10.00 3<br />

CMD6 — — — — — — 200 — 100 — 65 — — 600-800 S — 10.00 3<br />

NM — — — — — — 65 — 35 — 25 — — 600-800 S — 8.75 3<br />

VL HM — — — — — — 100 — 65 — 35 — — 600-800 S — 8.75 3<br />

LM — — — — — — 200 — 100 — 50 — — 600-800 S — 8.75 3<br />

SMD6 — — — — — — 65 — 50 — 25 — — 600-800 S — 10.00 3<br />

Sentron SHMD6 — — — — — — 100 — 65 — 50 — — 600-800 S — 10.00 3<br />

SCMD6 — — — — — — 200 — 100 — 65 — — 600-800 S — 10.00 3<br />

NN — — — — — — 65 — 35 — 25 — 22 800-1200 S — 10.00 3<br />

VL HN — — — — — — 100 — 65 — 35 — 25 800-1200 S — 10.00 3<br />

LN — — — — — — 200 — 100 — 50 — 42 800-1200 S — 10.00 3<br />

NXD6 — — — — — — 65 — 50 — 25 — 30 900-1200 S — 10.00 3<br />

ND6 — — — — — — 65 — 50 — 25 — 30 800-1200 S — 10.00 3<br />

Sentron HNXD6 — — — — — — 100 — 65 — 50 — 30 900-1200 S — 10.00 3<br />

HND6 — — — — — — 100 — 65 — 50 — 30 800-1200 S — 10.00 3<br />

CND6 — — — — — — 200 — 100 — 65 — — 900-1200 S — 10.00 3<br />

NN — — — — — — 65 — 35 — 25 — — 800-1200 S — 10.00 3<br />

VL HN — — — — — — 100 — 65 — 35 — — 800-1200 S — 10.00 3<br />

LN — — — — — — 200 — 100 — 65 — — 800-1200 S — 10.00 3<br />

SND6 — — — — — — 65 — 50 — 25 — — 800-1200 S — 10.00 3<br />

Sentron SHND6 — — — — — — 100 — 65 — 50 — — 800-1200 S — 10.00 3<br />

SCND6 — — — — — — 200 — 100 — 65 — — 800-1200 S — 10.00 3<br />

11 PANELBOARDS<br />

a BLG two-pole breaker is one phase and neutral. Three<br />

pole is two phases and neutral - See SpeedFax page 7-31<br />

b 1-pole HED 15-30A rated 65kA; 35-100A rated 25kA: 3-pole<br />

HED rated 42kA<br />

c Availability and additional specs tbd, expected late 2019.<br />

(COMPAS may allow selection of alternate trip units)<br />

d 2-pole only or two outer poles of 3-pole breaker<br />

e Accessories such as shunt trips on 3 pole breakers<br />

require 6.25" of unit space<br />

f Approved for CSA and UL Listed.<br />

g Approved for CSA but not UL Listed.<br />

Product Category PBSB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-89


Panelboards<br />

Power and Distribution<br />

Revised on 04/30/19<br />

Selection/Dimensions<br />

11<br />

PANELBOARDS<br />

Ampere<br />

Rating<br />

240V — Twin Mounted<br />

Mounting<br />

Height (inches)<br />

NEC Fuse Clips <br />

30-30 2½ <br />

30-30 5<br />

30-60 5<br />

60-60 5<br />

60-100 7½<br />

100-100 7½<br />

200-200 10<br />

240V — Single Mounted NEC Fuse Clips <br />

30 7½<br />

60 7½<br />

100 7½<br />

200 10<br />

200 7½<br />

400 10<br />

400 15<br />

600 15<br />

800 (HCP) 16¼<br />

1200 (HCP) 16¼<br />

Ampere<br />

Rating<br />

600V — Twin Mounted<br />

Mounting<br />

Height (inches)<br />

NEC Fuse Clips <br />

30-30 7½<br />

30-60 7½<br />

60-60 7½<br />

60-100 7½<br />

100-100 7½<br />

200-200 10<br />

600V — Single Mounted NEC Fuse Clips <br />

100 7½<br />

200 10<br />

400 10<br />

400 15<br />

400 (HCP) 15<br />

600 15<br />

600 15<br />

800 c (HCP) 16¼<br />

1200 c (HCP) 16¼<br />

Branch Breaker Side<br />

Gutter Inches (mm)<br />

Reference<br />

Letter<br />

Panel Width 38 Inches<br />

Dimensions in inches (mm)<br />

A 14.00 (356)<br />

B 13.98 (355)<br />

C 11.62 (295)<br />

D 10.00 (254)<br />

E 7.61 (193)<br />

F 8.75 (222)<br />

G 8.25 (210)<br />

H 10.90 (276)<br />

I 10.90 (276)<br />

J 11.76 (299)<br />

K 7.92 (201)<br />

L 8.00 (203)<br />

M 13.42 (341)<br />

N 12.00 (305)<br />

O 15.50 (393)<br />

P 14.25 (362)<br />

Q 13.42 (341)<br />

R 13.42 (341)<br />

S 10.00 (254)<br />

T 8.00 (203)<br />

U 10.50 (267)<br />

V 10.50 (267)<br />

W 9.30 (236)<br />

X 10.30 (262)<br />

Y 9.30 (236)<br />

Z 10.30 (262)<br />

AA 10.10 (257)<br />

AB 9.59 (244)<br />

AC 9.59 (244)<br />

A BL, BLH, HBL, BQD BL, BLH, HBL, BQD A<br />

B<br />

NGB, HGB, LGB<br />

NGB2, HGB2, LGB2<br />

NGB, HGB, LGB<br />

NGB2, HGB2, LGB2<br />

D ED4, ED6, HED4, HHED6 ED4, ED6, HED4, HHED6 D<br />

E CED6 CED6 E<br />

F QR2, QRH2, HQR2, HQR2H QR2, QRH2, HQR2, HQR2H F<br />

G<br />

FD6, FXD6,<br />

HFD6, HHFD6<br />

FD6, FXD6,<br />

HFD6, HHFD6<br />

AA 3VA52 – [MFAS, HFAS, CFAS] 3VA52 – [MFAS, HFAS, CFAS] AA<br />

H ND, HD, LD ND, HD, LD H<br />

AB<br />

3VA61 – [MDAE, HDAE,<br />

CDAE, LDAE]<br />

3VA61 – [MDAE, HDAE,<br />

CDAE, LDAE]<br />

I NF, HF, LF NF, HF, LF I<br />

AC<br />

3VA62 – [MFAE, HFAE,<br />

CFAE, LFAE]<br />

3VA62 – [MFAE, HFAE,<br />

CFAE, LFAE]<br />

J CFD J<br />

K<br />

JD6, JXD6,<br />

HJD6, HHJD6<br />

JD6, JXD6,<br />

HJD6, HHJD6<br />

L NJ, HJ, LJ NJ, HJ, LJ L<br />

M<br />

SJD6, SHJD6, LD6, LXD6,<br />

HLD6, HHLD6, SLD6, SHLD6<br />

M<br />

N CJD6, SCJD6, CLD6, SCLD6 N<br />

O NJ, HJ, LJ O<br />

P NL, HL, LL P<br />

Q NM, HM, LM Q<br />

R NN, HN, LN R<br />

S VB 30 A VB 30 A S<br />

T VB 30 - 60A VB 30 - 60A T<br />

U VB 60 -100A VB 60 -100A U<br />

V VB 200A VB 200A V<br />

W VB 100A Single W<br />

X VB 200A Single X<br />

Y VB 400 – 600A Single Y<br />

Z HCP 400 – 1200A Single Z<br />

B<br />

G<br />

AB<br />

AC<br />

K<br />

For inches / millimeters conversion,<br />

see Application Data section.<br />

a For Class J, R or T fuse clip prices, refer to page 11-92.<br />

b NEC fuse clips only.<br />

c 800 and 1200 ampere switches have class “L” fuse<br />

provisions. (Type HCP).<br />

11-90<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category PBSB


Panelboards<br />

Power and Distribution<br />

Revised on 04/30/19<br />

Selection/Dimensions<br />

Types P5 and SPP/FPP, F2 (12 3/4" deep)<br />

Connecting Strap Kits abc<br />

Circuit Breaker<br />

For use with P5, Sentron Deep or Type S5 Power Panels<br />

Max<br />

Amp<br />

Rating<br />

Breaker<br />

Family<br />

3VA Breaker Provision Kits<br />

Breaker Type Catalog Number Description<br />

3VA52, 3VA61 or<br />

3VA62 Breaker<br />

Breaker<br />

Type<br />

S3VA52PR<br />

Catalog<br />

Number 1<br />

Unit<br />

Height<br />

(inches)<br />

Contains the necessary<br />

hardware to land breaker<br />

on an existing strap kit<br />

Mounting<br />

100 General BL, BQD SBLBD 3.75 Twin<br />

125 General xGB SNBD 3.75 Twin<br />

General XGB2 SGB2D 3.75 Twin<br />

General ED SE6D 3.75 Twin<br />

General CED SCED 3.75 Twin<br />

150 VL DG SDGD 5.00 Twin<br />

3VA 3VA61 S3VA52TD h 5.00 Twin<br />

225 General QR SQRD 5.00 Twin<br />

250 Sentron FD SF6D 5.00 Twin<br />

VL FG SFGD 5.00 Twin<br />

Sentron CFD SCFD 5.00 Single<br />

3VA 3VA52, 3VA62 i S3VA52TD h 5.00 Twin<br />

400 Sentron JD SJ1D 8.75 Single<br />

Sentron JD SJ2D 8.75 Twin<br />

Sentron SJD SSJ1D 8.75 Single<br />

VL JG SJG1D 6.25 Single<br />

VL JG SJG2D 6.25 Twin<br />

Sentron CJD SCJD 8.75 Single<br />

Sentron SJD SCJD 8.75 Single<br />

600 Sentron LD SL6D 8.75 Single<br />

Sentron SLD SSL6D 8.75 Single<br />

VL LG SLGD 6.25 Single<br />

Sentron CLD SCLD 8.75 Single<br />

Sentron SCLD SSCLD 8.75 Single<br />

800 VL MG MG1D 8.75 Single<br />

Sentron LMD SLM1D 8.75 Single<br />

Sentron MD SMND 10.00 Single<br />

Sentron SMD SSMND 10.00 Single<br />

1200 VL NG NG1D 10.00 Single<br />

Sentron ND SMND 10.00 Single<br />

Sentron SND SSMND 10.00 Single<br />

Service Entrance Barriers<br />

Field installable Barriers to meet UL 67 service entrance requirements<br />

Breaker Type<br />

Catalog Number<br />

(S)JD, (S)LD, MG<br />

SEBP4V1<br />

CJD, CLD<br />

SEBP4V2<br />

JG, LG<br />

SEBP4V3<br />

(S)MD,(S)ND without shield<br />

SEBP5V1<br />

(S)MD,(S)ND with shield<br />

SEBP5V2<br />

Vacu-Break Switches<br />

SEBP5V3<br />

HCP Switches<br />

SEBP5V4<br />

Connecting Strap Kits c<br />

Fusible<br />

For use with P5, Sentron FPP Deep or<br />

Type F2 power panels<br />

Ampere<br />

Rating<br />

Unit Height<br />

(inches)<br />

30–30 2.5 F602D<br />

30–30 5, 7.5 F657D<br />

30–60 5, 7.5 F657D<br />

60–60 5, 7.5 F657D<br />

60–100 5, 7.5 F657D<br />

100–100 5, 7.5 F657D<br />

100 7.5 F657D<br />

200 7.5 F657D<br />

200 10 F671D<br />

200–200 10 F672D<br />

400–600 15 F6150D<br />

800–1200 d 16.25 F6162D<br />

12. 75" Deep Box<br />

CatalogNumber<br />

Blank Plates<br />

Circuit Breaker and Vacu-Break a<br />

For use with P5, Sentron SPP and<br />

Type S5 power panels<br />

Height<br />

Catalog<br />

(inches)<br />

Number<br />

1.25 6FPB01<br />

2.5 6FPB02<br />

3.75 6FPB03<br />

5.0 6FPB05<br />

10.0 6FPB10<br />

Filler Plates<br />

For use with P5, Sentron SPP and<br />

Type S5 power panels<br />

Filler Plate<br />

Breaker Type Catalog Number<br />

BL, BLH, HBL,<br />

BQD, ED4,<br />

ED6, HED4, HHED6, DFFP1 e<br />

NGB, HGB, LGB,<br />

NGB2, HGB2, LGB2,<br />

NEB, HEB<br />

EBF1<br />

Cover Plates<br />

For use with P5, Sentron SPP and<br />

Type S5 power panels<br />

Breaker Type Catalog Number<br />

QR<br />

SQRC <br />

11 PANELBOARDS<br />

For inches / millimeters conversion,<br />

see Application Data section.<br />

a Normal stock item.<br />

b Includes cover plate and mounting hardware,<br />

less circuit breaker.<br />

c Also fits Types FCI, FCII, SB1 and SB2 switchboards.<br />

d 800 –1200 amp units are HCP switch.<br />

Suitable to replace QF3 in P1 thru P5 Panelboards and<br />

Switchboards<br />

To replace a QJ with a QR only a new cover is needed<br />

up to 225A<br />

Although QR is rated 250A, it is limited to 225A in<br />

panelboard.<br />

h To field install a single 3VA52, 3VA61 or 3VA62 breaker<br />

to an existing strap, provision kit #S3VA52PR is required.<br />

i 3VA62 breaker will be available in Fall 2019.<br />

Note: When a front filler plate is not completely filled with<br />

breakers, the openings in the unused space must be<br />

closed with filler plates selected from this table.<br />

Product Category PBSB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-91


Panelboards<br />

Modifications and Additions<br />

Revised on 08/31/18<br />

Selection<br />

11<br />

PANELBOARDS<br />

Type P5 Panelboards<br />

Devices Mounted on Gutter Cover<br />

Includes Device, Mounting – Wired<br />

or Unwired<br />

Description<br />

One piece front with door<br />

(Depth increases to 14.25”)<br />

Hinged Gutter Covers 4 pc front<br />

Toggle Switch — SPST or 3-way<br />

15A, 277V maximum<br />

Pilot Light — General Purpose<br />

Neon or Incandescent<br />

Pushbutton<br />

Feed-Thru Lugs<br />

Ampere Rating Unit Space (inches)<br />

400 10<br />

600 10<br />

800 17.5<br />

1200 17.5<br />

Grounding of Panelboards<br />

Ground Bars except for brazed to box<br />

are shipped with the panel interior<br />

factory mounted.<br />

• Non-Insulated Equipment Ground<br />

Bar – Standard<br />

• Copper Non-Insulated Ground Bar<br />

• Al Insulated Equipment Ground Bar<br />

• Cu Insulated Equipment Ground Bar<br />

• Ground Bar Brazed to Box<br />

Fuse Clip Provisions<br />

(Add to 250 Volts or 600 Volts<br />

Unit Prices Per Switch)<br />

Amp<br />

Rating<br />

Class<br />

J<br />

• Indicates available<br />

Class<br />

R<br />

Class<br />

T<br />

30 • • N/A<br />

60 • • N/A<br />

100 • • •<br />

200 • • •<br />

400 N/A • •<br />

600 • • •<br />

Ground Fault on Main Breaker<br />

Description<br />

Conventional Ground<br />

Fault Includes:<br />

Ground Fault Relay, Ground<br />

Sensor, CPT and Shunt Trip<br />

Test and Monitor Panel <br />

Ground Fault add to<br />

Sensitrip III breaker price<br />

(takes 5” of unit space)<br />

Time Clocks <br />

Amp<br />

Rating<br />

Sangamo, Tork or Paragon time clock<br />

can be supplied, mounted in panelboard<br />

cabinet. For required increase<br />

in enclosure dimension, consult local<br />

sales office.<br />

Circuit Breaker Accessories<br />

Handle Blocking Device<br />

Blocks handle in either the<br />

“ON” or “OFF” position.<br />

800-1200<br />

800-1200<br />

Description<br />

Time clock (1- or 2-Pole, Single or<br />

Double Throw Contacts; 3-Pole Single<br />

Throw)<br />

277V Maximum with Plain Dial<br />

Optional:<br />

Astronomical Dial<br />

An Omitting Device<br />

Reserve Power or Carryover<br />

Space and Mounting Provisions Only<br />

Padlocking Device – Padlocks<br />

in “OFF” position.<br />

Main Bus<br />

Standard main bus and ground bus are<br />

tin-plated aluminum. For copper main<br />

bus, neutral bus and ground bus, add<br />

from the table for each panel.<br />

Lugs – For Main Lug Only Panels<br />

Standard main lugs and neutral lugs<br />

are tin-plated aluminum, UL listed for<br />

use with aluminum/copper cables.<br />

Copper only lugs are an option.<br />

Ampere Rating<br />

400 - 1200<br />

Shunt Trip on Main and Branches <br />

Description<br />

BL, BQD, NGB, HGB, LGB, NGB2,<br />

HGB2, LGB2 (branch only)<br />

QR2, QRH2, HQR2, HQR2H<br />

ED4, HED4, HHED6, CED6<br />

(branch only)<br />

All others to 1200A<br />

100% Rated Main Circuit Breakers<br />

Ampere<br />

Rating<br />

400<br />

Breaker<br />

Type<br />

JXD6H, HJXD6H<br />

NJY, HJY, LJY<br />

600 LXD6H, HLXD6H<br />

600 NMY, HMY, LMY<br />

NNY, HNY, LNY<br />

800 MXD6H, HMXD6U, SMD6,<br />

SHMD6, SND6, SHND6,<br />

NXD6H, HNXD6H<br />

NNY, HNY, LNY<br />

1200<br />

NXD6H, HNXDH,<br />

For use on main lug, main breaker or main switch<br />

panels without subfeed breakers.<br />

Available in 90” high enclosure only. Unit space is<br />

42½" with Test and Monitor Panel; 45" without Test<br />

Monitor Panel.<br />

Not available on Sensitrip III.<br />

For required unit space, consult local sales office.<br />

Shunt Trip on 100A frame breakers increases mounting<br />

height to 6.25” for twin mounting.<br />

The 600A, 100% rated braaker application requires the<br />

use of an 800A frame breaker.<br />

The 800A, 100% rated breaker application requires the<br />

use of a 1200A frame breaker.<br />

11-92<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category PBSB


Panelboards<br />

Embedded Micro Metering Module<br />

Revised on 04/30/19<br />

Selection<br />

SEM3 System configured in Panelboards<br />

The Siemens SEM3 system can be configured for factory<br />

installation in branch circuit monitoring applications using the<br />

Siemens COMPAS configuration tool. This option can lower<br />

the installation time of the system for the installer while providing<br />

a factory warrantied solution.<br />

The SEM3 system can be factory installed in unit space in<br />

type P2, P4, & P5 Siemens panel boards. Please note P1 and<br />

P3 configurations are not available at this time and the amount<br />

of unit space needed varies depending upon the application.<br />

Please note that lead time adders will apply and may vary<br />

depending upon the configuration of the system.<br />

11 PANELBOARDS<br />

SEM3 for use in Siemens Panelboards<br />

Available in a NEMA 1, 3R, or 12 rated enclosure<br />

Controller<br />

SEM3 controller is mounted in unit space opposite of the feed location specified in COMPAS<br />

(i.e., bottom mount for top feed) and will require 3” of unit space. Each controller will be powered<br />

by direct tap connection to the panel section bus. Each controller can monitor up to 45<br />

circuits. Applications that require monitoring more than 45 circuits will require additional controllers.<br />

Current Transformers (CTs)<br />

Seven sizes of CTs are available for use in the P5 panel: 50, 125, 250, 400, 600, 800, 1200<br />

amp. All CTs are pre-mounted to a support bracket that attaches to the base rail of the interior<br />

of the panel board. Each bracket supports a maximum of 3 CTs and is designed for the breaker<br />

selected (brackets are not interchangeable between breaker frames). Each CT will be attached<br />

to a data module that is placed in the meter racks.<br />

Meter Racks<br />

Each meter rack requires 3” of unit space. All meter racks will be installed next to the SEM3<br />

controller in unit space. The COMPAS configuration tool will select the appropriate meter rack<br />

configuration according to the user’s application and will use the 21 space meter rack as a<br />

default option where possible. Only one meter rack (regardless of number of positions) can be<br />

installed in 3” of unit space.<br />

NOTE: Monitoring of 45 circuits will require 9" of unit space: two 21 position racks and one 3<br />

position rack<br />

Other Considerations<br />

Configuration: Data modules from CTs monitoring a circuit breaker must be mounted adjacent<br />

to one another in the meter rack. Any field changes to the factory configuration must take<br />

this into account.<br />

Start-up & Commissioning: Siemens can provide these services. Contact your local<br />

SIEMENS PDS Power Solutions Business Developer for more details.<br />

Billing Services for sub billing applications: Billing services are available. Contact your local<br />

SIEMENS PDS Power Solutions Business Developer for more details.<br />

Product Category PBSB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-93


Panelboards<br />

Embedded Micro Metering Module<br />

Selection<br />

11<br />

PANELBOARDS<br />

P5 Devices<br />

Enclosure sizes<br />

Example P5 Panel with SEM3 Type 1 Enclosure<br />

P5 = (38" or 46" Wide x 10" Deep)<br />

Enclosure heights are in 15" increments from 60" thru 90".<br />

Enclosure heights: 60", 75", 90" (there are optional depths also)<br />

The COMPAS configuration tool can provide actual dimensions<br />

based on the configuration. Example below is largest standard<br />

P4 enclosure for factory assembled panel - unit space is in 3.75"<br />

increments - up to 6 circuits can occupy each 3.75" of unit space.<br />

38" std. width for P5<br />

Main Breaker / Main Lug space<br />

varies based on selected options<br />

Unit space varies<br />

based on selected options<br />

Note: All circuits do not have to be monitored<br />

by SEM3 - user can select any circuits in this<br />

space to be monitored.<br />

Based on smallest branch breakers and a 3-phase main<br />

being monitored. There is a maximum of 63 circuits that can<br />

be monitored with the configuration shown. Some<br />

selections of main breakers and other subfeed options could<br />

limit this further.<br />

In this situation there is 37.5" of unit space available -<br />

so 60 branch circuits could be monitored.<br />

If monitoring the main three additional circuits could<br />

be monitored with a total of 63 circuits.<br />

This requires two controllers and three 21 position<br />

racks using 18.75" of unit space.<br />

- see below -<br />

SEM3 space varies by number of circuits<br />

monitored - this uses unit space.<br />

== > 7.5" of space for up to 21 circuits monitored<br />

one controller and one 21-pos rack<br />

== > 11.25" of space for up to 42 circuits monitored<br />

one controller and two 21-pos racks<br />

== > 15" of space for up to 45 circuits monitored<br />

one controller and two 21-pos racks plus one 3-pos rack<br />

== > 18.75" of space for up to 63 circuits monitored<br />

two controllers and three 21-pos racks<br />

Note: If subfeed space is needed - it will take<br />

away from available unit space.<br />

11-94<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category PBSB


Panelboards<br />

Modifications and Additions<br />

Revised on 08/31/18<br />

Selection<br />

Type P5 Panelboards<br />

Vacu-Break Fusible Switches<br />

For Branch Circuit Use with AC Combination Full Voltage Starters <br />

Horsepower Ratings<br />

Mounting Height in Inches (mm)<br />

240V AC 480V AC 240V AC 480V AC<br />

Amp<br />

Rating<br />

With<br />

NEC Fuse<br />

With Dual-<br />

Element Fuse<br />

With NEC<br />

Fuse<br />

With Dual-<br />

Element Fuse Twin Single Twin Single<br />

Min. Section<br />

Width<br />

Inches (mm)<br />

30-30 3 7.5 — — 2.50 (64) — — — 32 (813)<br />

30-30 3 7.5 5 10 5.00 (127) — 7.50 (191) — 32 (813)<br />

30-60 3-7.5 7.5-15 5-15 25 5.00 (127) — 7.50 (191) — 32 (813)<br />

60-60 7.5 15 15 25 5.00 (127) — 7.50 (191) — 32 (813)<br />

60-100 7.5-15 15-30 15-25 25-50 7.50 (191) — 7.50 (191) — 32 (813)<br />

100-100 15 30 25 50 7.50 (191) — 7.50 (191) — 32 (813)<br />

100 — — 25 50 — — — 7.50 (191) 32 (813)<br />

200 25 50 50 100 — 10.00 (254) — 10.00 (254) 32 (813)<br />

200-200 — 50 — 100 10.00 (254) — 10.00 (254) — 32 (813)<br />

400 50 100 100 — — 10.00 (254) — 10.00 (254) 38 (965)<br />

400 50 100 100 — — 15.00 (381) — 15.00 (381) 38 (965)<br />

600 75 100 — — — 15.00 (381) — 15.00 (381) 38 (965)<br />

11 PANELBOARDS<br />

Connector Modifications<br />

Compression Lugs<br />

Style Amp Rating Breaker Type Compression Connectors Available Unit Space Reduction<br />

800 N/A All compression lugs Deduct 5.0” Unit Space<br />

MLO<br />

1000 N/A All compression lugs Deduct 5.0” Unit Space<br />

1200 N/A All compression lugs Deduct 5.0” Unit Space<br />

800<br />

MD6, HMD6, CMD6,<br />

SMD6, SHMD6,<br />

(3)#2/0 AWG - 500 Kcmil CU or Al 0<br />

Main Breaker<br />

1200<br />

SCMD6<br />

ND6, HND6, CND6,<br />

SND6, SHND6.<br />

SCND6<br />

(4)#250 - 500 Kcmil Cu or Al 0<br />

Alternate Lugs<br />

Style Amp Rating Breaker Type Compression Connectors Available Unit Space Reduction<br />

800 N/A (3)#3/0 AWG - 750 Kcmil Cu or Al Deduct 10” Unit Space<br />

(4)#3/0 - 600 Kcmil Cu or Al<br />

1000 N/A<br />

MLO<br />

(4)#3/0 AWG - 750 Kcmil Cu or Al<br />

Deduct 10” Unit Space<br />

1200 N/A<br />

(4)#3/0 AWG - 600 Kcmil Cu or Al<br />

(4)#3/0 AWG - 750 Kcmil CU or Al<br />

Deduct 10” Unit Space<br />

100,000 kA at 480V with Class J or Class RK5<br />

fuses.<br />

The 2.50 inch (64mm) high unit is suitable for NEC<br />

Class H and K5 fuses only. Class R rejection type fuse<br />

holders are not available.<br />

Product Category PBSB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-95


Panelboards<br />

Kits and Accessories<br />

Selection<br />

11<br />

PANELBOARDS<br />

Type P5 Panelboards<br />

Enclosures<br />

Description<br />

P5 Type 1 36" W x 12.75" D x 60" H<br />

P5 Type 1 36" W x 12.75" D x 75" H<br />

P5 Type 1 36" W x 12.75" D x 90" H<br />

P5 Type 1 36" W x 14.75" D x 60" H<br />

P5 Type 1 36" W x 14.75" D x 75" H<br />

P5 Type 1 36" W x 14.75" D x 90" H<br />

P5 Type 3R/12 60" H<br />

P5 Type 3R/12 75" H<br />

P5 Type 3R/12 90" H<br />

Catalog number<br />

PB860<br />

PB875<br />

PB890<br />

PBD860 <br />

PBD875 <br />

PBD890 <br />

WP860<br />

WP875<br />

WP890<br />

Trims<br />

Description<br />

P5 Std (4 piece trim) vented 60"<br />

P5 Std (4 piece trim) vented 75"<br />

P5 Std (4 piece trim) vented 90"<br />

P5 Std (4 piece trim) unvented 60"<br />

P5 Std (4 piece trim) unvented 75"<br />

P5 Std (4 piece trim) unvented 90"<br />

P5 Std (4 piece trim) vented 60" with hinged gutter covers<br />

P5 Std (4 piece trim) vented 75" with hinged gutter covers<br />

P5 Std (4 piece trim) vented 90" with hinged gutter covers<br />

P5 Std (4 piece trim) unvented 60" with hinged gutter covers<br />

P5 Std (4 piece trim) unvented 75" with hinged gutter covers<br />

P5 Std (4 piece trim) unvented 90" with hinged gutter covers<br />

P5 Std (1 PC Door) vented 60"<br />

P5 Std (1 PC Door) vented 75"<br />

P5 Std (1 PC Door) vented 90"<br />

P5 Std (1 PC Door) unvented 60"<br />

P5 Std (1 PC Door) unvented 75"<br />

P5 Std (1 PC Door) unvented 90"<br />

P5 Std (1 PC Door-in-door) vented 60"<br />

P5 Std (1 PC Door-in-door) vented 75"<br />

P5 Std (1 PC Door-in-door) vented 90"<br />

P5 Std (1 PC Door-in-door) unvented 60"<br />

P5 Std (1 PC Door-in-door) unvented 75"<br />

P5 Std (1 PC Door-in-door) unvented 90"<br />

Catalog number<br />

P560V<br />

P575V<br />

P590V<br />

P560NV <br />

P575NV <br />

P575NV <br />

P560VHG<br />

P575VHG<br />

P590VHG<br />

P560NVHG<br />

P575NVHG<br />

P590NVHG<br />

P560VD <br />

P575VD <br />

P590VD <br />

P560NVD <br />

P575NVD <br />

P590NVD <br />

P560VDD <br />

P575VDD <br />

P590VDD <br />

P560NVDD <br />

P575NVDD <br />

P590NVDD <br />

Flush mounting kits<br />

Description<br />

Flush kit to P5 60" High<br />

Flush kit to P5 75" High<br />

Flush kit to P5 90" High<br />

Catalog number<br />

F860<br />

F875<br />

F890<br />

Required with door over breaker handles.<br />

Unvented trims require amps per square inch bussing.<br />

Requires 14.5" deep box.<br />

11-96<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category PBSB


Panelboards<br />

Type P5 Panelboards<br />

Revised on 04/30/19<br />

Dimensions<br />

Type 1 Box<br />

Box is symmetrical<br />

4.37 in.<br />

[ 111 ]<br />

4.37 in.<br />

[ 111 ]<br />

6.63 in.<br />

[ 168 ]<br />

6.63 in.<br />

[ 168 ]<br />

0.31 in.<br />

[ 8 ]<br />

Mounting<br />

dimple<br />

0.31 in.<br />

[ 8 ]<br />

Mounting<br />

dimple<br />

11 PANELBOARDS<br />

14.04 in.<br />

[ 357 ]<br />

14.04 in.<br />

[ 357 ]<br />

4.37 in.<br />

[ 111 ]<br />

6.63 in.<br />

[ 168 ]<br />

4.37 in.<br />

[ 111 ]<br />

6.63 in.<br />

[ 168 ]<br />

12.75 in.<br />

[ 324 ]<br />

12.75 in.<br />

[ 324 ]<br />

Type 3R and 3R/12 Box<br />

0.49 in.<br />

[ 12 ]<br />

0.49 in.<br />

[ 12 ]<br />

16.08 in.<br />

[ 408 ]<br />

16.08 in.<br />

[ 408 ]<br />

0.83 in.<br />

[ 21 ]<br />

0.83 in.<br />

[ 21 ]<br />

38.37 in.<br />

[ 975 ]<br />

38.37 in.<br />

[ 975 ]<br />

16.00 in.<br />

[ 406 ]<br />

16.00 in.<br />

[ 406 ]<br />

0.93 in.<br />

[ 24 ]<br />

0.93 in.<br />

[ 24 ]<br />

14.76 in.<br />

[ 375 ]<br />

14.76 in.<br />

[ 375 ]<br />

Dimensions shown in inches and millimeters [ ].<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-97


Panelboards<br />

Circuit Breaker / Column Type<br />

General<br />

11<br />

PANELBOARDS<br />

Type C1<br />

240 Volts AC Maximum<br />

250 Ampere Mains<br />

250 Ampere Maximum Branch<br />

UL Short Circuit Rating —<br />

200,000 IR Maximum<br />

Branch Breaker Symmetrical<br />

Interrupting Rating<br />

Based on Underwriters’ Test Procedure<br />

Type C2<br />

480Y/277 Volts AC Maximum<br />

250 Ampere Mains<br />

250 Ampere Maximum Branch<br />

UL Short Circuit Rating —<br />

100,000 IR Maximum<br />

Meets NEC wire bending requirement,<br />

section 312–6.<br />

Panelboards<br />

Listed by Underwriter’s Laboratories,<br />

Inc., under “Panelboards” File #E2269.<br />

Meets Federal Specification<br />

W–C375B/Gen.<br />

Service<br />

240 Volts Maximum. 1-Phase, 3-Wire, or<br />

3-Phase, 4-Wire.<br />

Panelboards Fronts and Doors<br />

Standard panelboards are furnished with<br />

trim with a flush door lock. All are factory<br />

assembled for ease of installation. Fronts<br />

are fabricated from code gauge steel and<br />

finished ANSI-61.<br />

Main Breakers C1<br />

BL, BLH and HBL frame breakers are<br />

mounted horizontally. All other frames<br />

are mounted vertically.<br />

Main Breakers C2<br />

BQD frame breakers are mounted<br />

horizontally. All other frames are<br />

mounted vertically.<br />

Boxes<br />

C1 — 7 5 ⁄8" wide, 5 3 ⁄4" deep.<br />

C2 — 8 1 ⁄2" wide, 5 3 ⁄4" deep.<br />

Branch Breaker Side Gutters<br />

Circuit<br />

Side Gutter<br />

Type Breaker (inches)<br />

C1 BL, BLH, HBL 3.505<br />

C2 BQD 3.5<br />

Weight–Approximate<br />

Total panelboard weight when filled with<br />

a normal quantity of breakers and<br />

accessories is:<br />

*About 3 lbs. per inch of box height.<br />

Gauge Steel Boxes<br />

Type Width Height Gauge Steel<br />

C1 7 5 ⁄8" 48", 73", 85" #14<br />

C2 8 1 ⁄2" 48", 73", 85" #14<br />

Fronts<br />

C1 7 5 ⁄8" 48", 73", 85"* #14<br />

C2 8 1 ⁄2" 48", 73", 85"* #14<br />

*Note: Feed thru lugs and subfeed breaker not available<br />

for this height.<br />

Main Breaker Connectors<br />

Ampere<br />

Rating Connectors suitable for Cu or Al<br />

100 (1) #14–1/0 AWG<br />

125 (1) #4–1/0 AWG<br />

225 (1) #6 AWG–300 kcmil<br />

250 (1) #4 AWG–350 kcmil Al<br />

(1) #6 AWG–350 kcmil Cu<br />

Main Lugs<br />

125 (1) #6 AWG–350 kcmil<br />

250 (1) #6 AWG–350 kcmil<br />

For inches / millimeters conversion,<br />

see Application Data section.<br />

a Connector ranges indicated do not apply to all main breaker types. Refer to<br />

molded case circuit breaker standard pressure wire connectors in the breaker<br />

section of this catalog for the wire ranges for a specific breaker frame.<br />

11-98<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Panelboards<br />

Circuit Breaker / Column Type<br />

Revised on 05/15/18<br />

Selection<br />

Main Lugs Only C1<br />

Maximum<br />

Panel<br />

Ampere Rating<br />

Maximum<br />

1-Pole<br />

Circuits<br />

Box<br />

Height<br />

(inches)<br />

240 Volts Maximum<br />

208Y/120V 120/240V<br />

3-Phase, 4-Wire<br />

Catalog Number<br />

1-Phase, 3-Wire<br />

Catalog Number<br />

18 48 C1C18ML125CTS C1A18ML125CTS<br />

125<br />

30 73 C1C30ML125CTS C1A30ML125CTS<br />

42 85 C1C42ML125CTS C1A42ML125CTS<br />

18 48 C1C18ML250CTS C1A18ML250CTS<br />

250<br />

30 73 C1C30ML250CTS C1A30ML250CTS<br />

42 85 C1C42ML250CTS C1A42ML250CTS<br />

Main Circuit Breaker ab C1<br />

240 Volts Maximum<br />

18 48 C1C18BL100CTS C1A18BL100CTS<br />

100<br />

30 73 C1C30BL100CTS C1A30BL100CTS<br />

42 85 C1C42BL100CTS C1A42BL100CTS<br />

18 48 C1C18E4125CTS C1A18E4125CTS<br />

125<br />

30 73 C1C30E4125CTS C1A30E4125CTS<br />

42 85 C1C42E4125CTS C1A42E4125CTS<br />

18 48 C1C18QR225CTS C1A18QR225CTS<br />

225<br />

30 73 C1C30QR225CTS C1A30QR225CTS<br />

42 85 C1C42QR225CTS C1A42QR225CTS<br />

18 48 C1C18FX250CTS C1A18FX250CTS<br />

250<br />

30 73 C1C30FX250CTS C1A30FX250CTS<br />

42 85 C1C42FX250CTS C1A42FX250CTS<br />

11 PANELBOARDS<br />

Main Lugs Only C2<br />

Maximum<br />

Panel<br />

Ampere Rating<br />

Maximum<br />

1-Pole<br />

Circuits<br />

Box<br />

Height<br />

(inches)<br />

480Y/277 Volts Maximum<br />

480Y/277V<br />

3-Phase, 4-Wire<br />

Catalog Number<br />

18 48 C2E18ML125CTS<br />

125<br />

30 73 C2E30ML125CTS<br />

42 85 C2E42ML125CTS<br />

18 48 C2E18ML250CTS<br />

250<br />

30 73 C2E30ML250CTS<br />

42 85 C2E42ML250CTS<br />

Main Circuit Breaker ab C2<br />

480Y/277 Volts Maximum<br />

18 48 C2E18BD100CTS<br />

100<br />

30 73 C2E30BD100CTS<br />

42 85 C2E42BD100CTS<br />

18 48 C2E18E4125CTS<br />

125<br />

30 73 C2E30E4125CTS<br />

42 85 C2E42E4125CTS<br />

18 48 C2E18FX225CTS<br />

225<br />

30 73 C2E30FX225CTS<br />

42 85 C2E42FX225CTS<br />

18 48 C2E18FX250CTS<br />

250<br />

30 73 C2E30FX250CTS<br />

42 85 C2E42FX250CTS<br />

Alternate Main Breaker Selection ab C1<br />

Ampere<br />

Rating<br />

Breaker<br />

Type<br />

Maximum<br />

Interrupting<br />

Rating (KA)<br />

Catalog<br />

Number<br />

Available Trip Values<br />

BL 10 BL 50, 60, 70, 80, 90, 100<br />

100<br />

BLH 22 LH 50, 60, 70, 80, 90, 100<br />

HBL 65 HL 50, 60, 70, 80, 90, 100<br />

125<br />

ED4 65 E4 50, 60, 70, 80, 90, 100, 110, 125<br />

HED4 100 H4 50, 60, 70, 80, 90, 100, 110, 125<br />

HHED6 100 HA 50 (3-pole only)<br />

225 QR2 10 QR 100, 110, 125, 150, 175, 200, 225<br />

225<br />

FXD6 65 FX 70, 80, 90, 100, 110, 125, 150, 175, 200, 225<br />

HFD6 b 100 HF 70, 80, 90, 100, 110, 125, 150, 175, 200, 225<br />

250<br />

FXD6 65 FX 250<br />

HFD6 b 100 HF 250<br />

For inches / millimeters conversion,<br />

see Application Data section.<br />

a BL, BLH, HBL and BQD are horizontally mounted.<br />

All others vertically mounted.<br />

b Interchangeable trip breakers such as FD6 and HFD6<br />

cannot be back fed. Must be top feed only.<br />

Product Category PBSB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-99


Panelboards<br />

Circuit Breaker / Column Type<br />

Revised on 05/15/18<br />

Selection<br />

11<br />

PANELBOARDS<br />

Branch Breaker Selection C1<br />

Breaker<br />

Type<br />

Available<br />

Ampere<br />

Rating<br />

Maximum Interrupting<br />

Availability<br />

Rating (kA)<br />

1-Pole 2-Pole 3-Pole 120V 120/240V 240V<br />

15, 20, 30, 40, 50, 60 u u u — 10 —<br />

BL (120V) 70 u u u — 10 —<br />

70, 80, 90, 100 — u u — 10 —<br />

BL (HID) 15, 20, 30 u u — — — —<br />

BLF (GFCI)<br />

15, 20, 30 u u — 10 — —<br />

40, 50, 60 — u — 10 — —<br />

BLE (EQGFI) 15, 20, 30 u u — 10 — —<br />

BGL (SWN) 15, 20, 30 — u u 10 — —<br />

BLR (240V)<br />

15, 20, 30, 40, 50, 60 — u — — — 10<br />

70, 80, 90, 100 — u — — — 10<br />

15, 20, 30, 40, 50, 60 u u u — 22 —<br />

BLH (120V) 70 u u u — 22 —<br />

70, 80, 90, 100 — u u — 22 —<br />

BLHF (GFCI)<br />

15, 20, 30 u u — — 22 —<br />

40, 50, 60 — u — — 22 —<br />

HBL<br />

15, 20, 30, 40, 50 u u u — 65 65<br />

60, 70, 80, 90, 100 — u u — 65 65<br />

Subfeed Breakers — Limit One Per Panel b C1 (Not available for 42 circuit panels)<br />

ED4<br />

15, 20, 30, 40, 50, 60, 70, 80, 90, 100 —– u u — — 65<br />

110, 125 —– u u — — 65<br />

HED4<br />

15, 20, 30, 40, 50, 60, 70, 80, 90, 100 —– u u — — 65<br />

110, 125 —– u u — — 100<br />

HHED6 15, 20, 30, 40, 50 (3-pole only) —– — u — — 100<br />

QR2 100, 110, 125, 150, 175, 200, 225 —– u u — — 10<br />

FXD6 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250 —– u u — — 65<br />

HFD6 c 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250 —– u u — — 100<br />

Alternate Main Breaker Selection abc C2<br />

Ampere Breaker Catalog<br />

Rating Type IR Number Available Trip Values<br />

100 BQD 14 BD 50, 60, 70, 80, 90, 100<br />

ED4 18 E4 50, 60, 70, 80, 90, 100, 110, 125<br />

125 ED6 25 E6 50, 60, 70, 80, 90, 100, 110, 125<br />

HED4 42 H4 50, 60, 70, 80, 90, 100, 110, 125<br />

HHED6 65 HA 50 (3-pole only)<br />

225<br />

FXD6<br />

HFD6<br />

35<br />

65<br />

FX<br />

HF<br />

70, 80, 90, 100, 110, 125, 150, 175, 200, 225<br />

170, 80, 90, 100, 110, 125, 150, 175, 200, 225<br />

250<br />

FXD6<br />

HFD6<br />

35<br />

65<br />

FX<br />

HF<br />

250<br />

250<br />

Branch Circuit Breakers C2<br />

Breaker<br />

Type<br />

Available<br />

Ampere<br />

Rating<br />

Maximum Interrupting<br />

Availability<br />

Rating (kA)<br />

1-Pole 2-Pole 3-Pole 277V 480/277V 480V<br />

BQD<br />

15, 20, 30, 40, 50, 60 u u u 14 14 —<br />

70, 80, 90, 100 u u u 14 14 —<br />

Subfeed Breakers — Limit One Per Panel ab C2 (Not available for 42 circuit panels)<br />

ED4<br />

15, 20, 30, 40, 50, 60, 70, 80, 90, 100 —– u u — 18 18<br />

110, 125 —– u u — 18 18<br />

d 15, 20, 30, 40, 50, 60, 70, 80, 90, 100 —– u u — — 25<br />

ED6<br />

110, 125 —– u u — — 25<br />

HED4<br />

15, 20, 30, 40, 50, 60, 70, 80, 90, 100 —– u u — — 42<br />

110, 125 —– u u — — 42<br />

FXD6 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250 —– u u — — 35<br />

HFD6 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250 —– u u — — 65<br />

a No increase in box height. Space is already built into<br />

C1 panel.<br />

b BL, BLH, HBL and BQD are horizontally mounted.<br />

All others vertically mounted.<br />

c Interchangeable trip breakers such as FD6 and HFD6<br />

cannot be back fed. Must be top feed only.<br />

d ED6/CED6 2-pole limited amps available (20-50A)<br />

11-100<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category PBSB


Panelboards<br />

Circuit Breaker / Column Type, Modifications and Additions<br />

Selection<br />

Type C1/C2<br />

When required, special constructions or additions to standard<br />

panelboards may be specified for factory-assembled column<br />

panelboards.<br />

Box Modifications<br />

Description<br />

Gasketed<br />

Metal Card Holder<br />

Welded Metal Card Holder<br />

Nameplate<br />

Al Ground Bar<br />

Cu Ground Bar<br />

Insulated Al Ground Bar<br />

Insulated Cu Ground Bar<br />

Interior Modifications<br />

Description<br />

Feed-Thru Lugs<br />

Cu Neutral Lugs<br />

Cu main Lugs 125A<br />

Cu main Lugs 250A<br />

Box Sizing Chart<br />

Certain modifications such as subfeed breakers and feed-thru<br />

lugs require additional unit space. Use this chart to determine<br />

proper enclosure size.<br />

Box Height<br />

Panel Configuration<br />

(inches)<br />

All MLO 18 Circuit 48<br />

All MLO 30 Circuit 73<br />

All MLO 42 Circuit 85<br />

All MLO 18 Circuit with feed-thru lugs 73<br />

All MLO 30 Circuit with feed-thru lugs 85<br />

All MLO 18 Circuit with subfeed breaker 73<br />

All MLO 30 Circuit with subfeed breaker 85<br />

All Main Breaker 18 Circuit 48<br />

All Main Breaker 30 Circuit 73<br />

All Main Breaker 42 Circuit 85<br />

All Main Breaker 18 Circuit with feed-thru lugs 73<br />

All Main Breaker 30 Circuit with feed-thru lugs 85<br />

All Main Breaker 18 Circuit with subfeed breaker 73<br />

All Main Breaker 30 Circuit with subfeed breaker 85<br />

Column Extension<br />

Available in various standard lengths,<br />

extensions are 5 1 ⁄4 inches deep and<br />

7 inches wide.<br />

Height (inches) Catalog Number <br />

14 LXX-14<br />

20 LXX-20<br />

26 LXX-26<br />

32 LXX-32<br />

38 LXX-38<br />

41 LXX-41<br />

44 LXX-44<br />

53 LXX-53<br />

56 LXX-56<br />

62 LXX-62<br />

65 LXX-65<br />

68 LXX-68<br />

74 LXX-74<br />

80 LXX-80<br />

86 LXX-86<br />

Pull Boxes<br />

Two styles of pull boxes are available,<br />

top and front mounted. When the panel<br />

and its extensions are mounted in a<br />

structural WF beam a front mounted pull<br />

box is required. When the panels are<br />

surface mounted, a top mounted pull box<br />

may be used. Provisions are made so<br />

that the neutral bar may be mounted in<br />

the pull box when required.<br />

(Front mounted pull box dimensions are<br />

14" H. X 20" W.)<br />

Description<br />

Catalog Number <br />

Top Mount<br />

LXXP-T<br />

Front Mount LXX50-F<br />

11 PANELBOARDS<br />

Breaker Kits and Accessories<br />

Kit Number Description Contents<br />

MBKQRC1FK<br />

C1 Filler for QR in Main position<br />

1PH or 3PH<br />

Kit contains all cover plates necessary to change from<br />

QJ to QR both 2 and 3-pole breakers.<br />

For inches / millimeters conversion,<br />

see Application Data section.<br />

a Must be ordered as a manual line.<br />

Includes 50" extension.<br />

Product Category PBSB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-101


Panelboards<br />

Telephone and Equipment Cabinets<br />

Selection/Dimensions<br />

11<br />

PANELBOARDS<br />

Telephone and Equipment Cabinets: Conform to requirements of Underwriters’<br />

Laboratories, Inc., for all cabinets and boxes bearing their label. Surface and Flush<br />

enclosures: box and front constructed of code-gauge steel, box galvanized and front<br />

only finished with light gray, ANSI-61. Cabinets provided without backboards.<br />

Boxes: Standard construction has blank end walls, without knockouts.<br />

Fronts: Siemens Fas Latch fronts feature concealed hinges and fastening screws. Match<br />

P1 and P2 Panels in appearance. Two locks supplied on doors more than 51 inches high.<br />

Cabinets<br />

Dimensions (inches)<br />

Height Width Depth<br />

With FAS Latch Front<br />

Surface Mount<br />

Catalog Number<br />

29 20 5.75 TCS29B TCF29B<br />

41 20 5.75 TCS41B TCF41B<br />

47 20 5.75 TCS47B TCF47B<br />

59 20 5.75 TCS59B TCF59B<br />

Flush Mount<br />

Catalog Number<br />

Dimensions<br />

For inches / millimeters conversion,<br />

see Application Data section.<br />

a Add S for Surface, F for Flush.<br />

11-102<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category PBSB


Panelboards<br />

Enclosure Modifications<br />

Selection<br />

Customer Relay Cabinets<br />

Dimensions<br />

H W D Catalog Number<br />

23 20 5.75 RC(1)23B a<br />

23 24 5.75 RCW(1)23B <br />

11 PANELBOARDS<br />

Ampere<br />

Rating<br />

ASCO #920<br />

Mechanically held<br />

ASCO #911 — Mechanically held remote control<br />

switch suitable for all classes of loads (Total system<br />

loads). Voltage rated to 480V AC, UL listed.<br />

Siemens LEN<br />

Electrically Held<br />

2-Pole 3-Pole 3-Pole 2-Pole 3-Pole<br />

20 — — — — —<br />

30 u u — — u<br />

60 u u — — u<br />

75 u u — — —<br />

100 u u u — u<br />

150 u u u — —<br />

200 u u — — u<br />

225 u u — — —<br />

260 — — u — —<br />

300 — — u — —<br />

400 — — u — —<br />

600 — — u — —<br />

800 — — u — —<br />

1000 — — u — —<br />

1200 — — u — —<br />

u = available configurations<br />

Application (See individual panel sections for application information)<br />

Remote Control Switch Modification<br />

Description<br />

Auxiliary Contacts (Mounted Not Wired) Ea.<br />

2-Wire Control (add 6" to panel height.)<br />

Control Power Transformer<br />

Size<br />

VA<br />

0,1 50<br />

2 75<br />

3 150<br />

4 250<br />

Replace (1) with ”S” for surface applications and ”F”<br />

for flush applications.<br />

Includes Fas latch trim and steel mounting pan. If 2 or<br />

more cabinets are to be stackedn order (no extra charge<br />

for connecting hardware).<br />

Available in P4 or P5 only.<br />

Product Category PBSB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-103


Panelboards<br />

Modifications and Additions<br />

Revised on 04/11/17<br />

Selection<br />

11<br />

PANELBOARDS<br />

Standard Enclosures Made From<br />

Special Materials — Type P1, P2, P3<br />

Stainless Steel Options<br />

14GA 304 SS<br />

Front<br />

Grade (Brush Front) Front<br />

* Stainless available only for Screw-to-Box, Hinge-to-Box, and Door-in-Door.<br />

All have piano hinges only.<br />

**No special sizes. 20" and 24" wide only.<br />

Stainless Steel Additions to<br />

Enclosure Size (Type 1 Only)<br />

Width<br />

Depth<br />

Lighting Panel<br />

Order in 2" increments<br />

(30" max)<br />

Order in 2" increments<br />

(10" max)<br />

Consult factory for dimension limitations.<br />

Distribution Panels<br />

Order in 2" increments<br />

Order in 2" increments<br />

Miscellaneous<br />

Description.<br />

Conduit Hubs — Up to<br />

1 1/2 in. Each<br />

2 in. to<br />

2 1/2 in. Each<br />

3 in. Each<br />

Painted Finish<br />

Set-up Charge Net .<br />

Box Only<br />

Alternate Color Trim<br />

Front And Door Modifications<br />

Two Panels with Common Trim (14 GA only) <br />

Devices Mounted On Interior-Includes<br />

Device, Mounting (Wired or Unwired) <br />

Toggle Switch-SPST or 3-way; 15A, 277 V Maximum<br />

Pilot Light-General Purpose, Neon or Incandescent<br />

Pushbutton<br />

Gauge Steel of Boxes/Fronts, Surface and Flush (see pgs. 11-6 & 11-7)<br />

Dimensions in Inches (mm)<br />

Gauge Steel<br />

H W Box Front/Door Type<br />

26-74 (660-1880) 20 (508) 16 14 Type 1<br />

26-74 (660-1880) 20 (508) 16 16/14 Type 3R/12<br />

32-60 (813-1524) 20-36 (508-914) 14 14 Type 4<br />

26-74 (660-1879) 20 (508) 14 14 Type 4X<br />

36-60 (914-1524) 30-36 (762-914) N/A N/A Type 4X Non-Metallic<br />

16 Gauge is Standard (14 Gauge & 12 Gauge are optional)<br />

15 Gauge Steel Can with 14 Gauge Door or Similar Approved Construction<br />

No Optional Gauge available<br />

304SS 14 Gauge Std., 316SS 14 Gauge optional<br />

Sizes do not match Standard Enclosure Sizes - See Table P1-21 - material is non-metallic - No Gauge Specified.<br />

f FAS-Latch is 14 GA only.<br />

Screw-to-Box, Hinge-to-Box, Door-in-Door (14 GA Std./12 GA Std. or 10 GA Optional)<br />

STB/HTB/DND with Piano Hinge (14 GA Std./12 GA Optional)<br />

Note: For retro fit interiors and fronts into existing can, retro fit must match or exceed<br />

minimum height, width, and depth requirements of standard Type 1 enclosures.<br />

a Panels having doors over 48 in. high, 2 locks are standard.<br />

Lighting panels only. Field must supply dimensional<br />

information and panel orientation.<br />

11-104<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category PBSB


Panelboards<br />

Circuit Breaker Accessories and Modifications<br />

Revised on 04/30/19<br />

Selection<br />

Conduit Enclosing Shield (Panel Skirts)<br />

Sheet metal to cover conduits above or below a standard<br />

panelboard box.<br />

Skirt Length Width Depth<br />

8, 9, 11, 12, 14, 17, 18, 23, 25<br />

26, 27, 28, 29, 30, 31,<br />

32, 33, 34, 35, 36<br />

37, 38, 39, 40, 41, 42, 43, 44<br />

8, 9, 11, 12, 14, 17, 18, 23, 25<br />

26, 27, 28, 29, 30, 31,<br />

32, 33, 34, 35, 36<br />

37, 38, 39, 40, 41, 42, 43, 44<br />

20.00<br />

24.00<br />

5.75<br />

7.75<br />

Panel Skirts Standard Configurations<br />

Molded Case Switches a<br />

(Non-Automatic Circuit Interrupters)<br />

When Molded case switches are substituted for thermal<br />

breakers deduct from the installed thermal breaker price:<br />

Ampere<br />

Breaker<br />

Availability<br />

Rating Frame 3-Pole 2-Pole<br />

100 ED2 u u<br />

ED4 u u<br />

ED6 u u<br />

225 QR2 u u<br />

250 FXD6 u u<br />

400 JXD2 u u<br />

JXD6 u u<br />

600 LXD6 u u<br />

800 MD6 u u<br />

1200 ND6 u —<br />

11 PANELBOARDS<br />

3 Sides Open Back<br />

4 Sides Screw Front<br />

Notes:<br />

A) 4-sided skirts have standard Part Numbers (not catalog numbers).<br />

B) 3-sided skirts are ordered as Custom in COMPAS.<br />

C) Order in COMPAS with interior when possible.<br />

D) If ordered separate from interior, use a manual line in COMPAS.<br />

E) Must note if Top Entry or Bottom Entry required.<br />

Available only as a main switch for non-service<br />

equipment applications. Not available for branch<br />

devices.<br />

Product Category PBSB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-105


Panelboards<br />

Quik-Spec Coordination Panelboard<br />

Specifications<br />

11<br />

PANELBOARDS<br />

QuickShip<br />

All SQSCP configurations of the standard NEMA 1 enclosure can be<br />

specified for shipment within 10 business days of order when specified.<br />

Mains<br />

Assembly SCCRs<br />

Voltage ratings<br />

Bus amperages<br />

Branch circuits<br />

Panels<br />

Through-lugs<br />

& loadside<br />

disconnect<br />

Neutrals<br />

Grounds<br />

Enclosure sizes<br />

Spare fuses<br />

Options<br />

MLO (Main Lug Only)<br />

Fused disconnect switch<br />

Non-fused disconnect switch<br />

200kA, 100kA or 50kA AC, 100kA<br />

or 20kA@125Vdc <br />

Applicable on any 600Vac or less, or 125Vdc <br />

or less systems<br />

400A, 225A, 200A, 100A, 60A or 30A<br />

Circuits: 18, 30 or 42*<br />

Amps: Up to 100A<br />

Type: 1-, 2- and 3-Pole<br />

Feed: top & bottom<br />

Mounting: surface or flush<br />

Door/Trim: regular or door-in-door<br />

NEMA Ratings: 1 & 3R.<br />

Other ratings available, consult factory.<br />

Feed-Through: single and double<br />

Sub-Feed<br />

Feed/Sub-Through<br />

Fused loadside disconnect,<br />

(up to 1/2 of main amp rating)<br />

200A, 400A and 800A unbonded and bonded<br />

Non-isolated or isolated<br />

Standard size panelboard<br />

(20” W x 5¾” D x 33”- 69” H)*<br />

Spare fuse compartment holds up to six fuses<br />

Surge protection device (SPD) for high<br />

and low energy transients.*<br />

Depending on configuration.<br />

125Vdc rating applicable to only 80 amp or less CCPBs on MLO panels only.<br />

*Factory installed SPD options<br />

Discharge Current<br />

Data<br />

Sheet<br />

Number<br />

Nominal Maximum Response<br />

System & Voltage<br />

Catalog Number (I n ) (I max ) Time SCCR<br />

Single-phase, 120/240 BSPM2240S3G<br />

2150<br />

Three-phase Wye, 208/120 BSPM4208WYNG<br />

20 kA 40 kA ≤25 ns 200 kA<br />

2152<br />

Three-phase Wye, 480/277 BSPM4480WYNG 2152<br />

Delta, 480 BSPM3480DLG 2151<br />

11-106<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Panelboards<br />

Quik-Spec Coordination Panelboard<br />

Specifications<br />

Catalog Symbol: SQSCP4<br />

Description<br />

Panelboards for commercial/industrial<br />

branch or service entrance applications<br />

on systems up through 600Vac.<br />

Main options<br />

▪ Main lug only (MLO)<br />

▪ Fused main disconnect<br />

▪ Non-fused main disconnect<br />

11 PANELBOARDS<br />

The SQSCP is specifically designed<br />

to address the NEC ® Selective<br />

Coordination Requirements for<br />

Emergency, Legally Required Standby,<br />

Healthcare Essential Electrical and<br />

Critical Operation Power Systems<br />

(COPS) per NEC ® 700.28, 701.27,<br />

645.27 and 708.54. Not for applications<br />

requiring AFCI protected circuits. The<br />

SQSCP is configured to order for the<br />

application. To confirm availability of<br />

options and constructions, contact your<br />

Siemens distributor.<br />

Ratings<br />

Volts: 600Vac (or less), 125 Vdc<br />

Amps: 30, 60, 100, 200, 225, 400A<br />

SCCR: 20kA or 100kA @ 125Vdc–See<br />

panelboard short circuit ratings table for<br />

AC ratings.<br />

Agency information<br />

▪ UL 67–Standard for panelboards<br />

▪ UL 50/UL 50E–Enclosures for electrical<br />

equipment<br />

▪ CSA 22.2, No. 29-M1989–<br />

Panelboards and encl. panelboards<br />

▪ UL listed, class CTL panelboard (meets<br />

editions of the NEC prior to 2008 with<br />

regard to the NEC® 408.15 limit of<br />

42 overcurrent devices per panel)<br />

▪ UBC and CBC Seismic Qualified and<br />

IBC Approved<br />

Branch disconnect options<br />

▪ 1-, 2-, and 3-pole 15, 20, 30, 40, 50,<br />

60, 70, 90, and 100A rejecting branch<br />

disconnects (see table for details).<br />

Branch ampacity on 125Vdc panels<br />

limited to SCCPB 80A or less.<br />

Branch circuit positions<br />

▪ 18, 30 and 42<br />

Neutral options<br />

▪ Unbonded and bonded 200A, 400A<br />

and 800A<br />

Ground options<br />

▪ Isolated and non-isolated<br />

Enclosures<br />

▪ NEMA 1 and NEMA 3R. Other ratings<br />

available. Consult factory.<br />

Spare fuse compartment<br />

▪ Six space spare fuse compartment<br />

standard on all models<br />

Panelboard Short-circuit Current Ratings<br />

SCCR<br />

AC main options<br />

Main lug only<br />

(MLO) a<br />

70-200A main disc. no fuses a<br />

or w/ Class J fuses<br />

225-400A main disc. no fuses a<br />

or w/ Class J fuses<br />

SCCP_CF main<br />

disc. (60A) b<br />

High 200kA 200kA 100kA 200kA 100kA<br />

Std. 50kA 50kA 50kA 50kA 20kA<br />

a Class J, T or RK1 fuses upstream, max amps = panel amps.<br />

b CUBEFuse® disconnect<br />

DC<br />

Main lug only<br />

(MLO) a<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-107


Panelboards<br />

SCCPB Branch Disconnects, CUBEFuse ®<br />

Replacement parts and performance data<br />

11<br />

PANELBOARDS<br />

I<br />

J<br />

Fuse and disconnect performance data<br />

For details and specifications,<br />

access the following data sheets online at<br />

www.usa.siemens.com/panelboards<br />

CUBEFuse ® Specifications Catalog Symbols<br />

STCF_ (6-100A Indicating version)<br />

STCF_RN (1-100A Non-indicating version)<br />

Description<br />

The CUBEfuse ® is a finger-safe, dual-element, time delay UL<br />

Class CF power fuse with Class J fuse electrical performance<br />

charcteristics. 10 Seconds minimum operating time at 500%<br />

rated current.<br />

I – CCPB Branch Disconnects<br />

Poles Ampacity Part No.<br />

1-pole<br />

2-pole<br />

3-pole<br />

15A, 20A, 30A, 40A, 50A, 60A,<br />

70A, 90A, 100A<br />

J – CUBEFuse ® Fuses<br />

For CCPB Part No.<br />

SCCPB-(# of poles)-15CF<br />

SCCPB-(# of poles)-20CF<br />

SCCPB-(# of poles)-30CF<br />

SCCPB-(# of poles)-40CF<br />

SCCPB-(# of poles)-50CF<br />

Non-indicating Part<br />

No. STCF(amps)RN<br />

STCF1RN, STCF3RN,<br />

STCF6RN, STCF10RN,<br />

STCF15RN<br />

STCF17-1/2 RN<br />

STCF20RN<br />

STCF25RN<br />

STCF30RN<br />

STCF35RN<br />

STCF40RN<br />

STCF45RN<br />

STCF50RN<br />

SCCPB-1-(amp)CF<br />

SCCPB-2-(amp)CF<br />

SCCPB-3-(amp)CF<br />

Indicating Part<br />

No. STCF(amps)<br />

STCF6<br />

STCF10<br />

STCF15<br />

STCF17-1/2<br />

STCF20<br />

STCF25<br />

STCF30<br />

STCF35<br />

STCF40<br />

STCF45<br />

STCF50<br />

SCCPB-(# of poles)-60CF STCF60RN STCF60<br />

SCCPB-(# of poles)-70CF STCF70RN STCF70<br />

SCCPB-(# of poles)-90CF<br />

STCF80RN<br />

STCF90RN<br />

STCF80<br />

STCF90<br />

SCCPB-(# of poles)-100CF STCF100RN STCF100<br />

a CCPB disconnect can accept CUBEFuses® with amp ratings<br />

less than or equal to the amp rating of the SCCPB disconnect.<br />

1A indicating CUBEFuse® not available. Correct fit with SCCPB<br />

disconnect requires indicating CUBEFuse® with date code R38 or later.<br />

Ratings<br />

Volts: 600Vac/300Vdc<br />

Amps: 1-100 (non-indicating version)<br />

6-100 (indicating version)<br />

IR: 300kA RMS Sym. (UL)<br />

200kA RMS. Sym (CSA)<br />

100kA DC (UL & CSA)<br />

Agency Information<br />

▪ UL Listed Special Purpose Fuse: Guide JFHR,<br />

File E56412<br />

▪ CSA Certified Fuse: Class 1422- 02, File 53787<br />

▪ CE compliance for the European Union<br />

low voltage directive<br />

Other Ratings/Specifications<br />

Watts Loss at rated current: STCF30: 3.99W<br />

STCF60: 6.23W<br />

STCF100: 9.51W<br />

Operating and Storage Temperature Range<br />

14 to 149°F(-10 to 65°C)<br />

Material Specifications<br />

▪ Case: Glass filled PES (Polyethersulfone)<br />

▪ Terminals: Copper alloy<br />

▪ Terminal plating: Electroless tin<br />

▪ Indicator lens: PES (Polyethersulfone)<br />

(indicating version only)<br />

▪ Indicator: Energetic chemical<br />

CUBEFuse®, Low-Peak®, Quik-Spec, QuickShip, and<br />

easyID are valuable trademarks of Cooper Industries in the<br />

United States and other countries.<br />

11-108<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Panelboards<br />

SCCPB Branch Disconnects, CUBEFuse ®<br />

Specifications<br />

SCCPB Horsepower Ratings<br />

SCCPB Disconnect<br />

Amp<br />

Rating<br />

HP Rating @ Vac<br />

120 240 480 600<br />

SCCPB-(poles)-15CF 15 0.5 3 5 7.5<br />

SCCPB-(poles)-20CF 20 0.75 3 7.5 10<br />

SCCPB-(poles)-30CF 30 1.5 5 15 10<br />

SCCPB-(poles)-40CF 40 2 7.5 20 10<br />

SCCPB-(poles)-50CF 50 3 7.5 20 10<br />

SCCPB-(poles)-60CF 60 3 7.5 20 10<br />

SCCPB-(poles)-70CF 70 3 15 30 40<br />

SCCPB-(poles)-90CF 80 5 20 40 50<br />

SCCPB-(poles)-100CF 100 5 20 50 50<br />

11 PANELBOARDS<br />

Branch Disconnects<br />

SCCPB <br />

Part No.<br />

Poles<br />

Fuse Amp<br />

Range<br />

Max.<br />

SCCBP<br />

Amp.<br />

Non-indicating<br />

Fuses (Standard)<br />

Indicating<br />

Fuses (Opt’l) <br />

SCCPB-1-15CF 1<br />

SCCPB-2-15CF 2<br />

SCCPB-3-15CF 3<br />

1-15 15<br />

STCF1RN, STCF3RN,<br />

STCF6RN, STCF10RN,<br />

STCF15RN<br />

STCF6<br />

STCF10<br />

STCF15<br />

SCCPB-1-20CF 1<br />

SCCPB-2-20CF 2<br />

SCCPB-3-20CF 3<br />

17.5-20 20<br />

STCF17-1/2 RN<br />

STCF20RN<br />

STCF17-1/2<br />

STCF20<br />

SCCPB-1-30CF 1<br />

SCCPB-2-30CF 2<br />

SCCPB-3-30CF 3<br />

25-30 30<br />

STCF25RN<br />

STCF30RN<br />

STCF25<br />

STCF30<br />

SCCPB-1-40CF 1<br />

SCCPB-2-40CF 2<br />

SCCPB-3-40CF 3<br />

35-40 40<br />

STCF35RN<br />

STCF40RN<br />

STCF35<br />

STCF40<br />

SCCPB-1-50CF 1<br />

SCCPB-2-50CF 2<br />

SCCPB-3-50CF 3<br />

45-50 50<br />

STCF45RN<br />

STCF50RN<br />

STCF45<br />

STCF50<br />

SCCPB-1-60CF 1<br />

SCCPB-2-60CF 2<br />

60 60 STCF60RN STCF60<br />

SCCPB-3-60CF 3<br />

SCCPB-1-70CF 1<br />

SCCPB-2-70CF 2<br />

70 70 STCF70RN STCF70<br />

SCCPB-3-70CF 3<br />

SCCPB-1-90CF 1<br />

SCCPB-2-90CF 2<br />

SCCPB-3-90CF 3<br />

80-90 90<br />

STCF80RN<br />

STCF90RN<br />

STCF80<br />

STCF90<br />

SCCPB-1-100CF 1<br />

SCCPB-2-100CF 2<br />

SCCPB-3-100CF 3<br />

100 100 STCF100RN STCF100<br />

a SCCPB disconnect can accept CUBEFuses® with amp ratings less<br />

than or equal to the amp rating of the SCCPB disconnect.<br />

Correct fit with SCCPB disconnect requires indicating<br />

CUBEFuses® with date code R38 or later.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-109


Panelboards<br />

Enclosure/System Types, AC & DC Voltages<br />

11<br />

PANELBOARDS<br />

NEMA 1<br />

▪ Flush or surface mount.<br />

▪ Galvanized steel with removable end<br />

walls –blank or with knockouts to order.<br />

▪ Box sizes: 20” W x 5.75” D x 33”, 50”,<br />

59” or 69” H (510 W x 145 D x 838,<br />

1270, 1500 or 1753mm H). Box can be<br />

rotated 180° to accommodate conduit<br />

feed.<br />

▪ Enclosure and chassis mounting instructions<br />

are found in supplied literature.<br />

▪ Chassis mounts directly onto studs in<br />

the enclosure.<br />

▪ Trim finished with gray powder coat<br />

paint over phosphatized steel (ANSI 61).<br />

▪ Door and door-in-door configurations<br />

with locks.<br />

▪ Door locks use key #2A1910-2.<br />

▪ Circuit directory card is located on the<br />

inside of the door.<br />

▪ Trim screws are concealed.<br />

AC Voltages<br />

1 phase, 2 wire<br />

▪ 120V 1 phase, 2 wire<br />

▪ 240V 1 phase, 2 wire<br />

1 phase, 3 wire<br />

▪ 120/240V 1 phase, 3 wire<br />

1 phase, 2 wire, Wye<br />

▪ 277V 1 phase, 2 wire<br />

1 phase, 2 wire, Delta<br />

▪ 480V 1 phase, 2 wire<br />

A<br />

C<br />

B<br />

N<br />

A<br />

NEMA 3R<br />

▪ Surface mount only.<br />

▪ Finished with gray powder coat paint<br />

over phosphatized steel (ANSI 61).<br />

▪ Bottom feed only, no knockouts<br />

▪ Box sizes: 20” W x 7.7” D x 34.5”,<br />

51.5”, 60.5” or 70.5 H (510 W x 195 D<br />

x 876, 1310, 1535 or 1791mm H).<br />

▪ Enclosure and chassis mounting instructions<br />

are found in supplied literature<br />

▪ Chassis mounts directly onto studs in<br />

the enclosure.<br />

▪ Gasketed door has vault handle with<br />

lock.<br />

▪ Door locks use key #2A1910-1.<br />

▪ Circuit directory card is located on the<br />

inside of the door.<br />

Busing<br />

Tin-plated copper with sufficient cross section to meet UL 67 temperature<br />

rise requirements.<br />

Distributed 1- & 3-phase busing<br />

All SCCPB branch disconnects can be mounted in<br />

any branch circuit position.<br />

1 phase, 3 wire, Delta<br />

▪ 240/480V 1 phase, 3 wire<br />

3 phase, 4 wire, Wye<br />

▪ 208Y/120V 3 phase, 4 wire<br />

▪ 480Y/277V 3 phase, 4 wire<br />

▪ 600Y/347V 3 phase, 4 wire<br />

3 phase, 4 wire, Delta<br />

▪ 240/120V 3 phase, 4 wire<br />

▪ 480/240V 3 phase, 4 wire<br />

3 phase, 3 wire, Delta<br />

▪ 240V, 3 phase, 3 wire<br />

▪ 480V, 3 phase, 3 wire<br />

▪ 600V, 3 phase, 3 wire<br />

▪ 240V, 3 phase, 3 wire,<br />

grounded B<br />

▪ 480V, 3 phase, 3 wire,<br />

grounded B<br />

▪ 600V, 3 phase, 3 wire,<br />

grounded B<br />

1 phase, 3 wire, Wye<br />

▪ 208Y/120V 1 phase, 3 wire<br />

▪ 480Y/277V 1 phase, 3 wire<br />

C<br />

C<br />

A<br />

A<br />

B<br />

N<br />

B<br />

C<br />

A<br />

B<br />

N<br />

C<br />

A<br />

B<br />

A<br />

B<br />

C<br />

B<br />

N<br />

C<br />

DC voltage<br />

1 phase, 2 wire<br />

▪ 125Vdc, 2 wire<br />

N<br />

+125Vdc<br />

Single-phase<br />

Three-phase<br />

(Up to 125Vdc, MLO option<br />

only, SCCPB 40A or less.)<br />

11-110<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Panelboards<br />

Dimensions and Panelboard Configurations<br />

NEMA 1 and 3R Enclosure Dimensions<br />

Encl. Type<br />

NEMA 1<br />

Encl. Height<br />

Dimensions (inches)<br />

H HC MH CH DH RH SH DW D<br />

33 33.0 N/A 29.0 26.0 28.9 25.0 2.0 20.0 5.7<br />

50 50.0 N/A 43.0 40.0 37.9 39.0 3.5 20.0 5.7<br />

59 59.0 N/A 52.0 49.0 46.9 48.0 3.5 20.0 5.7<br />

11 PANELBOARDS<br />

69 69.0 N/A 62.0 59.0 56.9 58.0 3.5 20.0 5.7<br />

33 33.0 34.5 35.5 26.0 28.9 25.0 2.0 20.0 6.3<br />

NEMA 3R<br />

50 50.0 51.5 52.5 40.0 37.9 39.0 2.0 20.0 6.3<br />

59 59.0 60.5 61.5 49.0 46.9 48.0 2.0 20.0 6.3<br />

69 69.0 70.5 71.5 59.0 56.9 58.0 2.0 20.0 6.3<br />

Available panelboard configurations<br />

Based on enclosure height, panel amp rating and number of branch circuit positions<br />

Encl. height<br />

(inches)<br />

33” 30–200<br />

Panel amp rating<br />

Branch<br />

positions<br />

18<br />

Available configurations<br />

· Main lug only, with or without feed-through lugs<br />

· Non-fused disconnect, no loadside options<br />

30 · Main lug only, no loadside options<br />

18 · 30 through 60A fused main disconnect with or without feed-through lugs or TVSS device<br />

30–60<br />

30 · 30 through 60A fused main disconnect with or without feed-through lugs or TVSS device<br />

42 · 30 through 60A fused main disconnect with or without feed-through lugs or TVSS device<br />

50”<br />

59”<br />

70–200<br />

30–200<br />

225–400A<br />

70–200<br />

18 · 70 through 200A fused main disconnect with or without feed-through lugs or TVSS device<br />

30 · 70 through 200A fused disconnect with or without feed-through lugs<br />

18<br />

30<br />

42<br />

18<br />

· Main lug only with TVSS device<br />

· Non-fused disconnect, with feed-through lugs or TVSS device<br />

· Main lugs only, with feed-through lugs or TVSS device<br />

· Non-fused disconnect, with or without feed through lugs<br />

· Main lug only, with or without feed-through lugs or TVSS device<br />

· Non-fused disconnect, with or without feed-through lugs<br />

· Main lug only, with ot without feed through lugs or TVSS device<br />

· Non-fused disconnect, with or without feed-through lugs<br />

30 · Main lug only, with or without feed-through lugs<br />

30 · 70 through 200A fused main disconnect, with TVSS device<br />

42 · 70 through 200A fused main disconnect with or without feed-through lugs or TVSS device<br />

30–200 42 · Non-fused disconnect with TVSS device<br />

225–400A<br />

18<br />

30<br />

42<br />

· Main lug only with loadside disconnect<br />

· Non-fused disconnect, with TVSS device<br />

· 225 through 400A fused disconnect with or without feed-through lugs or TVSS device<br />

· Main lug only, with TVSS device<br />

· 225 through 400A fused disconnect, with no loadside options<br />

· Main lug only, with or without feed-through lugs or TVSS device<br />

· Non-fused disconnect, with no loadside options<br />

18 · Non-fused disconnect, with loadside disconnect<br />

69” 225–400A<br />

30<br />

42<br />

· Main lug only with loadside disconnect<br />

· 225 through 400A fused disconnect with feed-through lugs or TVSS device<br />

· Non-fused disconnect, with or without feed through lugs or TVSS device<br />

· 225 through 400A fused main disconnect, with or without feed-through lugs or TVSS device<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-111


Panelboards<br />

NEMA 1 and NEMA 3R<br />

Dimensions<br />

11<br />

PANELBOARDS<br />

NEMA 1 Enclosures<br />

and Interior<br />

1.1<br />

0.3<br />

0.5<br />

DETAIL A<br />

11.3<br />

2.2<br />

21 (7/8, 1-1/8)<br />

Concentric KO<br />

7.4<br />

Blank Endwall<br />

Knockout Endwall<br />

Enclosures Available with 2 Blank, 2 Knockout, or 1 Each Endwall<br />

3.1<br />

Flush Mount<br />

DW + 3.0<br />

Surface Mount<br />

DW<br />

2.9<br />

1.5<br />

(1-3/4, 2, 2-1/2, 3, 3-5/8, 4-1/8)<br />

Concentric KO<br />

Flush Mount<br />

DW + 3.0<br />

Surface Mount<br />

DW<br />

SH<br />

A<br />

Ground<br />

Door Lock<br />

Flush Mount<br />

H + 3.0<br />

CH<br />

MH<br />

Neutral<br />

RH<br />

H<br />

Surface Mount<br />

H<br />

DH<br />

Spare Fuse<br />

Compartment<br />

20.0<br />

16.0<br />

2.0<br />

D<br />

0.25 Mounting<br />

Hole Emboss<br />

Front View<br />

(Door in Door Option Shown on Right)<br />

Box with Interior<br />

Side View of Box<br />

0.2 0.5<br />

NEMA 3R Enclosures<br />

Interior same as NEMA 1<br />

SH 2.0<br />

DETAIL B<br />

SCALE 1 : 4<br />

Top End Wall (No Knockouts)<br />

B<br />

0.65<br />

7.68<br />

D<br />

0.6<br />

2X<br />

H<br />

MH<br />

HC<br />

Box Interior Same as NEMA 1<br />

13.0<br />

DW<br />

Front View<br />

Side View<br />

Bottom End Wall (No Knockouts)<br />

11-112<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Panelboards<br />

Fuse Curves<br />

Time-Current Characteristic Curves–<br />

Average Melt<br />

11 PANELBOARDS<br />

Current Limitation Curves<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-113


Panelboards<br />

Notes<br />

PANELBOARDS<br />

11<br />

11-114<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Lighting Controls<br />

SPEEDFAX TM<br />

Section<br />

Lighting Controls Business<br />

Discontinuation — Phase out of<br />

i-3 Control Technology V2<br />

Please note: Siemens Low Voltage & Products has exited the lighting control<br />

business.<br />

In 2012, we began the process with the phase out of LCP3000EZ. We are<br />

continuing this process by announcing the phase out of i-3 Control Technology.<br />

12 LIGHTING<br />

CONTROLS<br />

It is important to point out that Siemens is not exiting lighting control<br />

entirely. Our sister division Siemens Building Technologies supports a<br />

lighting control product called Gamma Lighting Control.<br />

The following is what to expect during this phase out process of i-3:<br />

1. No new system orders will be taken after September 30, 2014.<br />

2. Requirements for replacement parts will continue to be supported for product<br />

under warranty. The timing of the support is calculated based on existing<br />

warranty commitments as well as expected normal product mortality life.<br />

If you have any questions about this announcement or have the need for<br />

replacement parts for an existing system please contact your Siemens sales<br />

representative for more information and assistance.<br />

Scan to connect<br />

online to the<br />

most up-todate<br />

version of<br />

this Section of<br />

SPEEDFAX.<br />

(Section was last modified on 02/01/17)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 12-1


Lighting Controls<br />

Notes<br />

LIGHTING<br />

CONTROLS<br />

12<br />

12-2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Switchboards<br />

SPEEDFAX TM<br />

Section<br />

Front Connected Switchboard (Type SB2)<br />

c o n t e n t s<br />

Front Connected Switchboards 13-2 to 13-11<br />

Distribution Switchboards (Type SB1, SB2, SB3) 13-2 to 13-4<br />

Integrated Power Systems Switchboards (Type IPS) 13-5 to 13-6<br />

Commercial Multi-Metering Switchboards (Type SMM & MMS) 13-7<br />

Embedded Micro Metering Module (SEM3) 13-8<br />

Sm@rt DAS Type SB3 13-9<br />

Generator Ready Switchboards 13-10 to 13-11<br />

TPS3 Family of Hardwired Surge Protective Devices 13-12<br />

Rear Connected Switchboards (Type RCS) 13-13<br />

Stock Service Entrance Switchboards 13-14 to 13-22<br />

General Stock Switchboard Overview 13-14<br />

Super Blue Pennant Switchboards 13-15 to 13-20<br />

Circuit Breaker Stock Switchboard (Type BCT) 13-21<br />

Fusible Stock Switchboard (Type SCT) 13-22<br />

13 SWITCHBOARDS<br />

Switchboard Monitoring<br />

Sm@rtGear Mobile App 13-23 – 13-24<br />

Switchboard Replacement Parts and Modification Kits 13-25 – 13-26<br />

Integrated Power Systems Switchboard<br />

Rear Connected Switchboard (Type RCS)<br />

Scan to connect<br />

online to the<br />

most up-todate<br />

version of<br />

this Section of<br />

SPEEDFAX.<br />

(Section was last modified on 07/05/19)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 13-1


Distribution Switchboards<br />

Type SB1, SB2 and SB3<br />

General<br />

13<br />

SWITCHBOARDS<br />

Product Description<br />

Siemens modular front connected switchboard design<br />

provides a broad range of features and capabilities for a<br />

wide range of applications.<br />

Every aspect of design of Siemens switchboards has been<br />

aimed at improving layout convenience, reducing installation<br />

costs and minimizing the impact and cost of changes to the<br />

system.<br />

Siemens switchboards provide a rugged design and the<br />

flexibility necessary in electrical systems for all types of<br />

applications, some examples are:<br />

n Commercial buildings<br />

n Industrial plants<br />

n Retail chain stores<br />

n Health care facilities<br />

n Hi-rise complexes<br />

Features & Benefits<br />

Features<br />

n Up to 6000 ampere main bus rating<br />

n Up to 600 volts AC<br />

n Bus bracing up to 200KAIC<br />

n Tin plated aluminum bus, silver plated copper bus or tin<br />

plated copper bus<br />

n Bussing can be temperature or density rated<br />

n Type 1 and Type 3R enclosures<br />

n Main and branch circuit breakers and fusible switches<br />

n Thermal magnetic and solid state circuit breakers<br />

n Surge protective devices<br />

n Customer metering<br />

n Utility metering provisions<br />

n Ground fault protection on mains and distribution devices<br />

n Busway and transformer connections<br />

n ACCESS power monitoring on mains and branches<br />

Service Sections<br />

Typical switchboards require one or more service main<br />

disconnects that feed one or more distribution sections.<br />

Service sections can be fed from overhead or underground,<br />

occasionally underground applications require that a pull<br />

section to be added to the switchboard lineup.<br />

Distribution Sections<br />

All switchboard distribution sections can accommodate any<br />

combination of panel mounted or individually mounted circuit<br />

breakers or fusible switches. This modularity allows future<br />

system modifications to be made without adding switchboard<br />

sections.<br />

Front Accessibility<br />

All Siemens switchboards are rear aligned and front<br />

accessible, enabling switchboards to be placed against a wall,<br />

while minimizing floor space requirements. Switchboards are<br />

standard rear aligned to minimize floor space requirements<br />

but can be front and rear aligned as an option.<br />

Rear Accessibility<br />

Rear access is available as an option for when bus<br />

maintenance and cable entry and exit require access to the<br />

rear of the switchboard.<br />

Front Connected Distribution Switchboard (Type SB2)<br />

13-2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Distribution Switchboards<br />

Type SB1, SB2 and SB3<br />

General<br />

Features & Benefits (continued)<br />

Protective Devices<br />

Thermal magnetic molded case circuit breakers can be<br />

supplied from 15 to 2000 amperes. Solid state (electronic)<br />

molded case circuit breakers are available from 30 to 1600<br />

amperes. The solid state trip units provide finite trip setting<br />

adjustment, Modbus and Profibus communication along with<br />

many other features.<br />

WL insulated case UL489 circuit breakers can be provided<br />

from 200 to 5000 amperes with solid state trip units.<br />

For fusible applications, bolted pressure switches, high<br />

contact pressure switches and Vacu-Break fusible switches<br />

can be supplied.<br />

Power Monitoring<br />

Power monitoring can be accomplished in both service and<br />

distribution sections with a wide array of ACCESS power<br />

monitoring products. Digital and analog meters can be applied<br />

as well as branch circuit monitoring devices for tenant subbilling<br />

or cost allocation applications. See section 9 of the<br />

<strong>Speedfax</strong> for further information on power monitoring devices.<br />

Standards and Certifications<br />

n UL891<br />

n NEMA PB-2<br />

n Seismically qualified<br />

n Other equipment is UL listed as applicable<br />

Additional Information<br />

For complete application and pricing information contact<br />

your local Siemens sales office.<br />

For further information on the product, visit our website at<br />

www.usa.siemens.com/switchboards<br />

For detailed configuration information consult the selection<br />

and application guide on the website.<br />

13 SWITCHBOARDS<br />

Surge Protective Devices<br />

Siemens surge protective devices can be applied in<br />

switchboards to improve the electrical system’s protection,<br />

safety and reliability. These devices can be applied in<br />

customer metering compartments in main service sections<br />

or can be panel mounted in auxiliary compartments in<br />

distribution sections. See section 10 of the <strong>Speedfax</strong> for<br />

further information on surge protection devices.<br />

Arc Flash Mitigation<br />

Many arc flash mitigating features can be incorporated into<br />

switchboards. The WL breaker can be provided with Dynamic<br />

Arc Flash Sentry to allow for safer device settings when<br />

personnel are working near the switchboard. Also, breaker<br />

shutters, remote racking devices and infrared scanning<br />

windows can be supplied to further protect personnel from<br />

potential arc flash hazards.<br />

Busway and Transformer Connections<br />

Busway and transformer incoming and outgoing connections<br />

can be provided in switchboards. For busway connections to<br />

the switchboard, bussing is provided up to where the busway<br />

enters the switchboard. Also, a cutout for the busway is<br />

provided to allow for quick connection of the switchboard to<br />

the busway. For transformer connections, flex connectors are<br />

supplied for close coupling the switchboard to the secondary<br />

side of the unit substation.<br />

Front Connected Distribution<br />

Switchboard (Type SB2)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 13-3


Distribution Switchboards<br />

Type SB1, SB2 and SB3<br />

Revised on 05/15/18<br />

General<br />

Individual Product lines<br />

SB1 Switchboards<br />

Siemens SB1 switchboards have been specifically designed<br />

for the shortest lead times and for applications where floor<br />

space is at a premium. The rear of all sections align so the<br />

switchboard can be installed against a wall. SB1 switchboards<br />

can contain main and branch protective devices and through<br />

bus ratings up to 2000 amperes and 600 Volts AC.<br />

SB3 Switchboards<br />

Siemens SB3 switchboards are designed for custom<br />

options. SB3 switchboards can incorporate custom busway<br />

& transformer connections, rear access, all types of utility<br />

metering provisions and many other options. No matter your<br />

need, Siemens SB3 switchboards can provide a solution.<br />

13<br />

SWITCHBOARDS<br />

SB2 Switchboards<br />

Siemens SB2 switchboards have been designed to be able to<br />

incorporate additional features. SB2 switchboards can have<br />

extra depth behind the bussing in each distribution section,<br />

can be front and rear aligned and can handle up to 4000<br />

amperes and 600 Volts AC. These switchboards may also<br />

include insulated case circuit breakers, solid state molded<br />

case circuit breakers and density rated bussing.<br />

SB1 Switchboards<br />

Available Features<br />

Device<br />

Usage<br />

Device Type<br />

Ampere<br />

Rating<br />

Mounting<br />

• Individual or panel mounted mains<br />

• Individual or panel mounted branches<br />

• Thermal magnetic MCCBs<br />

• 2000A maximum main bus<br />

• Front accessible<br />

• Rear Aligned<br />

• Standard Utility Metering Position<br />

• Customer metering: digital & analog meters<br />

• 65KAIC interruption rating<br />

• 65C Copper and Aluminum bussing<br />

• Type 1 and 3R enclosures<br />

• Integrated lighting panelboards<br />

Main<br />

Branch<br />

Molded Case Circuit Breakers (MCCB)<br />

Molded Case Circuit Breakers (MCCB)<br />

Vacu-Break Switches (VBS)<br />

Vacu-Break Switches (VBS)<br />

High Contact Pressure Switches (HCP)<br />

Bolted Pressure Switches (BPS)<br />

Molded Case Circuit Breakers (MCCB)<br />

Molded Case Circuit Breakers (MCCB)<br />

Vacu-Break Switches (VBS)<br />

Vacu-Break Switches (VBS)<br />

High Contact Pressure Switches (HCP)<br />

Bolted Pressure Switches (BPS)<br />

400 - 1200<br />

400 - 2000<br />

400 - 600<br />

800 - 1200<br />

800 - 1200<br />

800 - 2000<br />

15 - 1200<br />

400 - 2000<br />

30 - 600<br />

800 - 1200<br />

400 - 1200<br />

800 - 1200<br />

Panel<br />

Individual<br />

Panel<br />

Individual<br />

Individual<br />

Individual<br />

Panel<br />

Individual<br />

Panel<br />

Individual<br />

Individual<br />

Individual<br />

SB2 Switchboards<br />

Available Features<br />

Device<br />

Usage<br />

Device Type<br />

Ampere<br />

Rating<br />

Mounting<br />

• All SB1 options<br />

• 4000A maximum main bus<br />

• Electronic trip unit (solid state) MCCBs<br />

• Density rated copper and aluminum bussing<br />

• 100KAIC interruption rating<br />

• Standard Maintenance Mode DAS (Dynamic Arc Sentry)<br />

Main<br />

Branch<br />

All SB1 main devices<br />

Bolted Pressure Switches (BPS)<br />

WL Insulated Case Circuit Breakers (WL)<br />

All SB1 branch devices<br />

Bolted Pressure Switches (BPS)<br />

WL Insulated Case Circuit Breakers (WL)<br />

Up to 4000<br />

Up to 4000<br />

Up to 4000<br />

Up to 4000<br />

Individual<br />

Individual<br />

Individual<br />

Individual<br />

SB3 Switchboards<br />

Available Features<br />

Device<br />

Usage<br />

Device Type<br />

Ampere<br />

Rating<br />

Mounting<br />

• All SB1 & SB2 options<br />

• 6000A maximum main bus<br />

• 200KAIC interruption rating<br />

• Rear accessible<br />

• Custom busway and transformer connections<br />

• Additional special options and configurations<br />

Main<br />

Branch<br />

All SB1 & SB2 main devices<br />

Bolted Pressure Switches (BPS)<br />

WL Insulated Case Circuit Breakers (WL)<br />

All SB1 & SB2 branch devices<br />

Bolted Pressure Switches (BPS)<br />

WL Insulated Case Circuit Breakers (WL)<br />

Up to 6000<br />

Up to 5000<br />

Up to 6000<br />

Up to 5000<br />

Individual<br />

Individual<br />

Individual<br />

Individual<br />

13-4<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Integrated Power Systems Switchboards<br />

Type IPS<br />

General<br />

Product Description<br />

Siemens integrated power systems (IPS) switchboards<br />

integrate multiple pieces of electrical distribution equipment<br />

into a single assembly. The design results in reduced<br />

installation time, a reduced footprint and reduced labor risk<br />

for installation.<br />

The modular design of the IPS switchboard allows it to be<br />

combined with standard service entrance or distribution<br />

switchboards if needed. Also, the IPS switchboard can be<br />

added to an existing switchboard lineup.<br />

IPS switchboards have a wide range of applications and are<br />

commonly used in retail stores, offices, health care facilities<br />

and retrofits.<br />

Features & Benefits<br />

Integrated Power Systems Switchboard<br />

Commonly Mounted Equipment<br />

Features<br />

n All standard SB1, SB2 & SB3 switchboard features<br />

n Lighting panelboards<br />

n Distribution transformers<br />

n Half high distribution switchboard chassis<br />

n Individually mounted breakers (cable in & cable out)<br />

n Auxiliary sections for surge devices, ACCESS power<br />

monitoring, contactors, relays, time clocks, motor starters,<br />

customer equipment, etc.<br />

13 SWITCHBOARDS<br />

1<br />

Distribution sections<br />

n Up to 3000A (full height)<br />

n Up to 1200A (half height)<br />

3<br />

2<br />

Transformers<br />

n Up to 300KVA (full height)<br />

n Up to 150KVA (half height)<br />

1<br />

2<br />

3<br />

Panelboards<br />

n Up to 800A (full height)<br />

n Up to 600A (half height)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 13-5


Integrated Power Systems Switchboards<br />

Type IPS<br />

General<br />

Features & Benefits (continued)<br />

Reduced Installation Time<br />

IPS switchboards arrive at a jobsite with the components<br />

factory installed and wired. The result is significantly reduced<br />

installation time. The realized savings on installation result in<br />

lower labor costs which drops directly to the bottom line.<br />

Standards and Certifications<br />

n UL891<br />

n NEMA PB-2<br />

n Seismically qualified<br />

n Mounted panelboards built to UL67 and NEMA PB-1<br />

n Other equipment is UL listed as applicable<br />

13<br />

SWITCHBOARDS<br />

Reduced Space Requirements<br />

By integrating components that are typically individually<br />

mounted, the IPS switchboard can reduce the space<br />

requirements for typical electrical equipment installation by<br />

up to 40%. This smaller footprint frees up valuable square<br />

footage that can be utilized by the building owner for other<br />

profitable uses.<br />

Reduced Installation Risk<br />

IPS switchboards are assembled at Siemens manufacturing<br />

plants with meticulous attention to details reinforced with<br />

strict testing procedures. This focus on quality ensures that<br />

problems encountered with traditional installations such<br />

as misinterpretation of drawings or field installation errors<br />

are eliminated. Utilizing IPS switchboards eliminates risks,<br />

enabling projects to come in on time and on budget.<br />

Additional Information<br />

For complete application and pricing information contact your<br />

local Siemens sales office.<br />

For further information on the product, visit our website at<br />

www.usa.siemens.com/switchboards<br />

For detailed configuration information consult the selection<br />

and application guide on the website.<br />

Integrated Power Systems Switchboard<br />

Optimized electrical room layout<br />

Traditional layout<br />

Integrated power systems layout<br />

Panelboard<br />

Panelboard<br />

Panelboard<br />

Transformer<br />

Panelboards<br />

Panelboards<br />

Transformer<br />

& 2-Panelboards<br />

4-Panelboards<br />

n 50% reduction<br />

in required<br />

floor space<br />

n 90% reduction<br />

in installation<br />

time<br />

13-6<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Commercial Multi-Metering Switchboards<br />

Type SMM & MMS<br />

General<br />

Product Description<br />

Siemens commercial multi-metering switchboards<br />

provide utility metering for multiple tenants. The sockets<br />

and protective devices are cable connected at the factory<br />

making the sockets ready for the installation of the meters.<br />

With the modular design of Siemens switchboards all<br />

multi-metering sections can be combined with standard<br />

main service or distribution sections.<br />

Multi metering switchboards can be used in many<br />

applications, some of the most common are:<br />

n Shopping centers<br />

n Office buildings<br />

n Retail chain stores<br />

Features & Benefits<br />

Features<br />

n Up to 4000 ampere main bus rating<br />

n Up to 600 volts AC<br />

n Bus bracing up to 200KAIC<br />

n Type 1 and Type 3R enclosures<br />

n Standard hot sequence metering with optional cold<br />

sequence metering<br />

n 100, 200 or 320 ampere meter sockets<br />

n Sockets include lever type manual bypass<br />

n Ring-less type meter cover design<br />

n Type 1 and Type 3R ratings<br />

n All other SB1, SB2 & SB3 switchboard features<br />

Individual Product Lines<br />

Type SMM<br />

Type SMM switchboards are specifically designed for the<br />

west coast and meet all EUSERC requirements.<br />

13 SWITCHBOARDS<br />

Type MMS<br />

Type MMS switchboards are designed for non-EUSERC<br />

territories and are designed to meet the specific requirements<br />

of any local utility.<br />

Standards and Certifications<br />

n UL891<br />

n NEMA PB-2<br />

n Seismically qualified<br />

n Other equipment is UL listed as applicable<br />

Additional Information<br />

For complete application and pricing information contact your<br />

local Siemens sales office.<br />

For further information on the product, visit our website at<br />

www.usa.siemens.com/switchboards<br />

SMM Commercial<br />

Multi-Metering Switchboard<br />

For detailed configuration information consult the selection<br />

and application guide on the website.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 13-7


Switchboards<br />

Embedded Micro Metering Module<br />

Selection<br />

SEM3 System configured in Distribution Panels and Switchboards<br />

The information below pertains to panelboard types P4, P5<br />

and switchboard types SB1, SB2, and SB3. Please note<br />

SEM3 is not available for P3 panelboards. SEM3 is available in<br />

NEMA type 1, 3R, and 12 enclosures. SEM3 specifics to P4,<br />

P5, SB1, SB2, and SB3 are:<br />

13<br />

SWITCHBOARDS<br />

SEM3 for use in Siemens Switchboards<br />

Controller<br />

SEM3 controller is mounted in unit space. For P4 and P5 panels it will be mounted opposite<br />

of the feed location specified in COMPAS (i.e., bottom mount for top feed). The controller<br />

will require 3.75” of unit space in P4/5 and SB1/2/3. Each controller will be powered by direct<br />

tap connection to the section bus and can monitor up to 45 circuits. Applications that require<br />

monitoring more than 45 circuits will require additional controllers. For multi-section applications<br />

each controller will only be connected to meter racks in the same section as the controller.<br />

Current Transformers (CTs)<br />

Six sizes of CTs are available for use in P4/5 & SB1/2/3 applications: 50, 125, 250, 400, 600,<br />

and 1200 amp. All CTs are pre-mounted to a support bracket that attaches to the interior. Each<br />

bracket supports a maximum of 3 CTs and is designed for the breaker selected (brackets are<br />

not interchangeable between breaker frames). Each CT will be attached to a data module that is<br />

placed in the meter racks.<br />

Meter Racks<br />

Each meter rack requires 3.75” of unit space. All meter racks will be installed next to the SEM3<br />

controller in unit space. The COMPAS configuration tool will select the appropriate meter rack<br />

configuration according to the user’s application and will use the 21 space meter rack as a<br />

default option where possible. Only one meter rack (regardless of number of positions) can be<br />

installed in 3.75” of unit space. For multi-section applications each rack will only be connected<br />

to data modules from CTs in that section. Racks will not be setup to monitor CTs from adjacent<br />

sections.<br />

NOTE: Monitoring of 45 circuits will require 9" of unit space: two 21 position racks and one 3<br />

position rack<br />

Other Considerations<br />

Configuration: Data modules from CTs monitoring a circuit breaker must be mounted adjacent<br />

to one another in the meter rack. Any field changes to the factory configuration must take this<br />

into account.<br />

Start-up & Commissioning: Siemens can provide these services. Contact your local SIEMENS<br />

PDS Power Solutions Business Developer for more details.<br />

Billing Services for sub billing applications: Billing services are available. Contact your local<br />

SIEMENS PDS Power Solutions Business Developer for more details.<br />

13-8<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Switchboards<br />

Revised on 04/14/17<br />

Sm@rt DAS Type SB3<br />

What is the solution?<br />

n Simple, scalable – Can integrate all MCCBs, ICCBs and<br />

Power Circuit Breakers in a single system<br />

n Consistent Architecture - System can be used in most<br />

equipment including Switchgear, Switchboards, and Power<br />

Panels<br />

n Outside the Zone - Maintenance switches can be mounted<br />

on a remote panel outside arc flash zone<br />

What are the benefits?<br />

n Complies with NEC 240.87<br />

n Scalable solution to add multiple breakers<br />

n Can set instantaneous to any required value -- not just<br />

fixed values<br />

n Can be utilized on both WL, VL breakers<br />

n MODBUS communication – allows for additional control<br />

over a SCADA system or local HMI<br />

Standard Features<br />

n Siemens Sm@rt DAS controller with MODBUS TCP/IP<br />

n MODBUS communication linking intelligent devices<br />

n One light/switch per breaker<br />

n Power/Insulated Case Circuit Breaker features<br />

• ETU 776<br />

• COM16 (MODBUS module)<br />

• Ability to change all protection setting parameters<br />

n Molded Case Circuit Breaker Features:<br />

• ETU 586<br />

• COMMOD21 (MODBUS module)<br />

• Ability to change short time and instantaneous<br />

protection setting parameters<br />

DAS Optional Features<br />

n Optional single switch for entire system with indicator<br />

lights for individual breakers<br />

n Optional HMI<br />

• Remote activation<br />

• Adjust trip settings on breakers<br />

13 SWITCHBOARDS<br />

DAS Architecture<br />

Activation switch<br />

(1 per breaker)<br />

Upstream<br />

PMCS, DCS,<br />

PCS or SCADA<br />

systems via<br />

MODBUS TCIP<br />

Indicator lights<br />

(1 per breaker)<br />

Controller<br />

HMI (optional)<br />

Low-Voltage<br />

Power Breaker<br />

Insulated Case<br />

Breaker<br />

Molded Case<br />

Circuit Breaker<br />

Molded Case<br />

Circuit Breaker<br />

Molded Case<br />

Circuit Breaker<br />

Switchboard with Sm@rt DAS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 13-9


Generator Ready Switchboards<br />

Type Generator Ready<br />

Product Description<br />

Features & Benefits<br />

13<br />

SWITCHBOARDS<br />

Siemens Generator Ready quick connect switchboards meet<br />

the market need for quick connection of a generator for<br />

temporary back-up power.<br />

The most common application of these switchboards are<br />

retail stores with perishable items, nursing homes & hospitals.<br />

However, these types of switchboards should be applied in<br />

any application that is sensitive to power outages.<br />

Features<br />

n All standard SB1, SB2 & SB3 switchboard features<br />

n Crouse-Hinds quick-connect Cam-Loks for a quick primary<br />

connection method<br />

n Standard mechanical lugs suitable for use with Type W<br />

welding cable for a secondary connection method<br />

n NEMA 1 and NEMA 3R enclosures<br />

n Trap door on NEMA 3R enclosure to maintain rating with<br />

cables connected<br />

n Labeled phases and ground connections<br />

n Bus connection between generator breaker and plug-in<br />

quick connects<br />

n Mechanical interlocking with normal breaker<br />

n Removable screw cover for covering quick-connects when<br />

not in use<br />

n Stand alone or hard bussed in standard switchboard lineup<br />

Generator Breaker Compartment<br />

The generator breaker can be connected to the normal main<br />

switchboard by cable or bus. The generator breaker should<br />

be key-interlocked with the main breaker in the normal<br />

switchboard lineup. The switchboard can rated Suitable for<br />

Service Entrance (SUSE).<br />

Quick-Connect Compartment<br />

The Crouse-Hinds quick-connect Cam-Loks are provided in<br />

a compartment with a removable screw cover covering the<br />

quick-connects for when they are not in use. In addition to<br />

the quick-connects, standard mechanical lugs are provided as<br />

a secondary method of connection. The mechanical lugs are<br />

rated for Type W welding cable which is common in these<br />

generator connection applications.<br />

Generator Ready Switchboard in NEMA 3R Enclosure<br />

Outgoing Connection<br />

The outgoing load connection of the generator breaker can be<br />

accomplished through either cable connection or can be hard<br />

bussed to an existing or new switchboard lineup.<br />

4/0 Crouse-Hinds quick connect Cam-Lok<br />

Standards and Certifications<br />

n UL891<br />

n NEMA PB-2<br />

n NEC702<br />

n Florida Building Code section 420.4.2.9.7<br />

n Seismically qualified<br />

n Other equipment is UL listed as applicable<br />

13-10<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Generator Ready Switchboards<br />

Type Generator Ready<br />

Product Features<br />

1 2<br />

3<br />

1<br />

2000A main WL generator<br />

breaker key interlocked with<br />

normal main breaker<br />

Hinged NEMA 3R door to<br />

maintain NEMA 3R rating with<br />

cables connected<br />

13 SWITCHBOARDS<br />

3<br />

4<br />

4<br />

2<br />

2000A of Crouse-Hinds Cam-Loks<br />

for a three phase four wire system<br />

with ground connections<br />

Standard mechanical lugs suitable<br />

for use with Type W welding<br />

cable as a secondary method of<br />

connection<br />

Common Application<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 13-11


Surge Protective Devices in Switchboards<br />

Revised on 04/14/17<br />

TPS3 Family of Hardwired Surge Protective Devices<br />

TPS3 Integral or Internally Mounted<br />

SPDs for Switchboards<br />

Siemens Integral TPS3 06 and L6 are UL 1449 4th Edition,<br />

factory installed SPDs within our Siemens Switchboards,<br />

utilizing optimal electrical system connections to minimize<br />

impedance losses. This results in the some of the industry’s<br />

best “installed” Voltage Protection Ratings. These SPDs<br />

share the following features:<br />

13<br />

SWITCHBOARDS<br />

TPS3 Features<br />

n UL 1449 4th Edition and UL 1283<br />

n UL 1449-4 Type 2 SPD, UL 1283 Listed, CSA 22.2 No.<br />

269.2, Optional UL 1449 4th Edition Recognized Type 1,<br />

CSA 22.2<br />

n 20 kA I n (Most models)<br />

n 200 kA SCCR (most models)<br />

n UL96A Lightning Protection Master Label Compliant<br />

n 100 – 500 kA surge current capacity per phase<br />

n EMI/RFI filtering or Sine Wave tracking<br />

n Standard Monitoring – LEDs, Audible Alarm, Dry Contacts,<br />

Surge Counter, and Ground Reference Monitoring (GRM)<br />

Diagnostics<br />

n 10 Year Product Warranty<br />

TPS3 06<br />

Ordering Information<br />

Catalog #<br />

TPS3<br />

06 X<br />

Voltage Code<br />

A = 120/240 V, 1Ø, 3W<br />

Surge Current (kA)<br />

10 = 100 kA per phase<br />

X = Surge counter<br />

(Standard)<br />

B = 120/240 V, 3Ø, 4W 15 = 150 kA per phase Options<br />

C = 120/208 V, 3Ø, 4W 20 = 200 kA per phase<br />

D = 240 V, 3Ø, 25 = 250 kA per phase B = Busway application<br />

3W<br />

E = 277/480 V, 3Ø, 4W 30 = 300 kA per phase M = MCC application<br />

F = 480 V, 3Ø, 3W <br />

G = 600 V, 3Ø, 3W <br />

40 = 400 kA per phase<br />

50 = 500 kA per phase<br />

K = 380/220 V, 3Ø, 4W<br />

L = 600/347 V, 3Ø, 4W<br />

S = 400/230 V, 3Ø, 4W<br />

When an option is not selected, include a zero (0) in the field.<br />

Available Accessories: Ordered Separately<br />

RMSIE = Remote monitor WHXWDP120 = 10’ Display cable extension<br />

G voltage code only available in 200 & 250 kA<br />

Not available in 500 kA<br />

Example: TPS3C0640X002 = Type 2 SPD (Default) for a 208/120V switchboard<br />

with a surge current capacity of 400 kA per phase and a surge counter.<br />

Options<br />

2 = Type 2 SPD (Default)<br />

Includes UL 1283 EMI/<br />

RFI Filters<br />

0 = Type 1 SPD<br />

“True,” “Discrete,” or “L-L Enhanced” 10 Mode SPD<br />

Catalog #<br />

TPS3 L6<br />

X<br />

Voltage Code<br />

A = 120/240 V, 1Ø, 3W<br />

B = 120/240 V, 3Ø, 4W<br />

C = 120/208 V, 3Ø, 4W<br />

E = 277/480 V, 3Ø, 4W<br />

K = 380/220 V, 3Ø, 4W<br />

S = 400/230 V, 3Ø, 4W<br />

Surge Current (kA)<br />

15 = 150 kA per phase<br />

30 = 300 kA per phase<br />

45 = 450 kA per phase<br />

Available Accessories: Ordered Separately<br />

RMSIE = Remote monitor<br />

X = Surge counter<br />

(Standard)<br />

Options<br />

B = Busway application<br />

M = MCC application<br />

Example: TPS3CL645X02 = 10 mode Type 2 SPD (Default) for a 208/120V switchboard<br />

with a surge current capacity of 450 kA per phase and a surge counter.<br />

When an option is not selected, include a zero (0) in the field.<br />

Options<br />

2 = Type 2 SPD (Default)<br />

Includes UL 1283 EMI/<br />

RFI Filters<br />

0 = Type 1 SPD<br />

13-12<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Rear Connected Switchboards<br />

Type RCS<br />

General<br />

Siemens RCS switchboards differ from<br />

the front connected (Type SB1, SB2,<br />

SB3) design primarily in the distribution<br />

sections. In the distribution section<br />

the branch feeders are individually<br />

mounted. Because of this method of<br />

mounting, access to the outgoing cable<br />

terminals must be from the rear of<br />

the unit. Bus bar extensions from the<br />

feeder devices are run to the rear of<br />

the RCS section stopping before the<br />

conduit area for easy access and cable<br />

connection.<br />

An optional cable management system<br />

can be requested to secure the<br />

outgoing cables. The front and rear<br />

of all sections align and are designed<br />

for mounting away from the wall.<br />

RCS switchboard will accommodate<br />

requirements up to 6000 ampere<br />

and 600 volts. The main bus can be<br />

specified for 400 to 6000 ampere<br />

rating. Main, tie and branch devices<br />

are available in amperage ratings up to<br />

6000 amps. RCS switchboards can be<br />

indoor (NEMA 1) or outdoor (NEMA 3R)<br />

construction.<br />

RCS switch boards utilize Type WL<br />

insulated case and/or low-voltage<br />

power circuit breakers with drawout<br />

mountings. Features and benefits<br />

include high breaker density, 100kA<br />

standard short circuit bus bracing<br />

and three levels of horizontal bus.<br />

Options include insulated/isolated bus,<br />

Dynamic Arc Flash Sentry, ModBus<br />

Communication and intelligent power<br />

monitoring.<br />

13 SWITCHBOARDS<br />

Switchboard<br />

Type RCS<br />

Mounting<br />

WL Insulated Case<br />

Circuit Breaker<br />

Drawout Mount<br />

WL LV Power<br />

Circuit Breaker<br />

Drawout Mount<br />

Main Devices Individual 400-5000A 400-5000A<br />

Branch Devices Individual 400-5000A 400-5000A<br />

For additional information on this product visit our website at www.sea.siemens.com.<br />

For application pricing information contact your local distributor or the closest Siemens sales office.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 13-13


Stock Service Entrance Switchboards<br />

Product Description and Application<br />

General<br />

13<br />

SWITCHBOARDS<br />

Product Description<br />

Siemens stock service entrance switchboards are designed as<br />

stock units to meet the fast delivery needs of the market.<br />

All of Siemens stock switchboards are suitable for service<br />

entrance. These switchboards combine utility metering<br />

provisions and a main service disconnect that can either be a<br />

Vacu-Break fusible switch or a molded case circuit breaker.<br />

Stock switchboards have many applications, some of the<br />

most common include:<br />

n Retail stores<br />

n Office buildings<br />

n Small factories<br />

n Commercial stores and shopping centers<br />

Individual Product Lines<br />

Super Blue Pennant<br />

n Specifically designed to meet EUSERC requirements<br />

n Provision for EUSERC utility metering<br />

n Main fusible switch or circuit breaker<br />

n Optional distribution panel<br />

BCT Service Cubicle<br />

n Provision for utility metering (non-EUSERC)<br />

n Main molded case circuit breaker<br />

SCT Service Cubicle<br />

n Provision for utility metering (non-EUSERC)<br />

n Main Vacu-Break fusible switches<br />

Additional Information<br />

For complete application and pricing information contact your<br />

local Siemens sales office.<br />

For further information on the product, visit our website at<br />

www.usa.siemens.com/switchboards<br />

For detailed configuration information consult the selection<br />

and application guide on the website.<br />

Super Blue Pennant BCT Service Cubicle SCT Service Cubicle<br />

13-14<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Stock Service Entrance Switchboards<br />

Super Blue Pennant Switchboards<br />

General<br />

Product Description<br />

Siemens Super Blue Pennant stock service entrance<br />

switchboards are designed as stock units to meet the fast<br />

delivery needs of the market.<br />

Super Blue Pennant switchboards are suitable for service<br />

entrance and are specifically designed to meet EUSERC<br />

requirements. They combine utility metering provisions<br />

with either a main Sentron molded case circuit breaker<br />

or Vacu-Break fusible switch. An optional plug-in or bolt<br />

on distribution panel can also added in the field in the<br />

same section.<br />

Super Blue Pennant switchboards have many applications,<br />

some of the most common include:<br />

n Retail stores<br />

n Office buildings<br />

n Small factories<br />

n Commercial stores and shopping centers<br />

Features & Benefits<br />

Features<br />

n Up to 800 amperes<br />

n Up to 480 volts AC<br />

n Bus bracing up to 200KAIC<br />

n Type 1 or Type 3R enclosures<br />

Utility Provision<br />

Incoming main lugs are mechanical screw-type, mounted on<br />

studs and accept a wide range of cable sizes. A barriered hot<br />

sequence utility metering compartment is supplied which<br />

meets all EUSERC requirements. The meter and test block<br />

provisions are also built to meet EUSERC requirements.<br />

Main Disconnect<br />

The main service disconnect can be either a Sentron molded<br />

case circuit breaker in 400, 600 or 800 amperes or a Vacu-<br />

Break fusible switch in 400 or 600 amperes.<br />

13 SWITCHBOARDS<br />

Distribution Panel<br />

Super Blue Pennant switchboards can accommodate an<br />

optional distribution panel assembly per unit with ratings of<br />

400, 600 or 800 amperes. The distribution panel can take up<br />

to 40 single pole branch breakers which can be either bolt on<br />

or plug-in.<br />

Standards & Certifications<br />

n UL891<br />

n NEMA PB-2<br />

n Seismically qualified<br />

n Other equipment is UL listed as applicable<br />

Super Blue Pennant<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 13-15


Stock Service Entrance Switchboards<br />

Super Blue Pennant Switchboards<br />

Dimensions<br />

Type 1 — Indoor<br />

Type 3R — Outdoor Weatherproof<br />

SWITCHBOARDS<br />

13<br />

Dimensions (inches)<br />

Description A B C<br />

Without Lug Landing 46 14 12<br />

With Lug Landing 58 26 24<br />

Dimensions (inches)<br />

Description A B C<br />

Without Lug Landing 53 15 13<br />

With Lug Landing 65 27 25<br />

For inches / millimeters conversion, see conversion table<br />

in Application Data section.<br />

13-16<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Stock Service Entrance Switchboards<br />

Super Blue Pennant Switchboards<br />

Selection<br />

Main Circuit Breaker<br />

Main Device<br />

Ampere<br />

Rating<br />

Service<br />

Voltage<br />

Meter Distribution Approximate<br />

Catalog Number Socket Kits<br />

Weight (lbs.)<br />

Indoor Outdoor Clips Available Indoor Outdoor<br />

400 Ampere<br />

Line Lugs<br />

(2)— 3 ⁄0-500<br />

kcmil (Copper<br />

or Aluminum)<br />

Breaker Rated<br />

65,000A IR<br />

Symmetrical<br />

at 240 Volts<br />

35,000A IR<br />

Symmetrical<br />

at 480 Volts<br />

Type JD6<br />

600 Ampere<br />

Line Lugs<br />

(2)— 3 ⁄0-500<br />

kcmil (Copper<br />

or Aluminum)<br />

Breaker Rated<br />

65,000A IR<br />

Symmetrical<br />

at 240 Volts<br />

35,000A IR<br />

Symmetrical<br />

at 480 Volts<br />

Type LD6<br />

120/240; 1-Phase,<br />

3-Wire<br />

240/120; 3-Phase,<br />

4-Wire Delta<br />

240; 3-Phase,<br />

3-Wire<br />

208Y/120; 3-Phase,<br />

4-Wire<br />

480Y/277; 3-Phase,<br />

4-Wire<br />

480; 3-Phase,<br />

3-Wire<br />

120/240; 1-Phase,<br />

3-Wire<br />

240/120; 3-Phase,<br />

4-Wire Delta<br />

240; 3-Phase,<br />

3-Wire<br />

208Y/120; 3-Phase,<br />

4-Wire<br />

480Y/277; 3-Phase,<br />

4-Wire<br />

480; 3-Phase<br />

3-Wire<br />

PB224 WPB224 5 PQ2630<br />

PQ2612<br />

PB424 WPB424 15<br />

PB444 WPB444 15<br />

PQ4630<br />

PQ4612<br />

PE4630<br />

PF4606<br />

PB226 WPB226 5 PQ2630<br />

PQ2612<br />

PB426<br />

WPB426<br />

PB446 WPB446 15<br />

15 PQ4630<br />

PQ4612<br />

PE4630<br />

PF4606<br />

320 1050<br />

335 1060<br />

335 1060<br />

320 1050<br />

335 1060<br />

335 1060<br />

13 SWITCHBOARDS<br />

800 Ampere<br />

Line Lugs<br />

(3)— 3 ⁄0-500<br />

kcmil (Copper<br />

or Aluminum)<br />

Breaker Rated<br />

65,000A IR<br />

Symmetrical<br />

at 240 Volts<br />

50,000A IR<br />

Symmetrical<br />

at 480 Volts<br />

Type MD6<br />

120/240; 1-Phase,<br />

3-Wire<br />

240/120; 3-Phase,<br />

4-Wire Delta<br />

240; 3-Phase,<br />

3-Wire<br />

208Y/120; 3-Phase,<br />

4-Wire<br />

480Y/277; 3-Phase,<br />

4-Wire<br />

480; 3-Phase,<br />

3-Wire<br />

PB228 WPB228 5 PQ2840<br />

PQ2816<br />

PB428 WPB428 15<br />

PB448<br />

WPB448<br />

PQ4840<br />

PQ4818<br />

15 PE4840<br />

PF4809<br />

460 1090<br />

475 1090<br />

475 1090<br />

For inches / millimeters conversion, see conversion table<br />

in Application Data section.<br />

a Load side lugs, distribution panel and subfeed kits are<br />

not included.<br />

b For 6-jaw requirements, order 6th clip kit<br />

from accessories.<br />

= Warehouse Stock<br />

Product Category SWBD<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 13-17


Stock Service Entrance Switchboards<br />

Super Blue Pennant Switchboards<br />

Selection<br />

Main Fusible Switch <br />

Main Device<br />

Ampere<br />

Rating<br />

Service<br />

Voltage<br />

Meter Distribution Approximate<br />

Catalog Number Socket Kits<br />

Weight (lbs.)<br />

Indoor Outdoor Clips Available Indoor Outdoor<br />

120/240; 1-Phase,<br />

3-Wire<br />

PF224 WPF224 5 PQ2630<br />

PQ2612<br />

365 1094<br />

13<br />

SWITCHBOARDS<br />

400 Ampere<br />

Line Lugs<br />

(2)— 3 ⁄0-500<br />

kcmil (Copper<br />

or Aluminum)<br />

200,000 AIC<br />

maximum at<br />

600 Volts<br />

240/120; 3-Phase,<br />

4-Wire Delta<br />

240; 3-Phase,<br />

3-Wire<br />

208Y/120; 3-Phase,<br />

4-Wire<br />

480Y/277; 3-Phase,<br />

4-Wire<br />

480; 3-Phase,<br />

3-Wire<br />

120/240; 1-Phase,<br />

3-Wire<br />

PF424 WPF424 15<br />

PF444 WPF444 15<br />

PQ4630<br />

PQ4612<br />

PE4630<br />

PF4606<br />

PF226 WPF226 5 PQ2630<br />

PQ2612<br />

375 1110<br />

375 1110<br />

370 1100<br />

600 Ampere<br />

Line Lugs<br />

(2)— 3 ⁄0-500<br />

kcmil (Copper<br />

or Aluminum)<br />

200,000 AIC<br />

maximum at<br />

600 Volts<br />

240/120; 3-Phase,<br />

4-Wire Delta<br />

240; 3-Phase,<br />

3-Wire<br />

208Y/120; 3-Phase,<br />

4-Wire<br />

480Y/277; 3-Phase,<br />

4-Wire<br />

480; 3-Phase<br />

3-Wire<br />

PF426<br />

WPF426<br />

PF446 WPF446 15<br />

15 PQ4630<br />

PQ4612<br />

PE4630<br />

PF4606<br />

390<br />

1110<br />

390 1120<br />

For inches / millimeters conversion, see conversion table<br />

in Application Data section.<br />

aFuses not included.<br />

bLoad side lugs, distribution panel and subfeed kits are<br />

not included.<br />

c For 6-jaw requirements, order 6th clip kit<br />

from accessories.<br />

= Warehouse Stock<br />

13-18<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category SWBD


Stock Service Entrance Switchboards<br />

Super Blue Pennant Switchboards<br />

Revised on 05/15/18<br />

Selection<br />

Main Device (Circuit Breaker or Fusible Switch)<br />

Load Side Lugs — Discount Schedule SWBD<br />

Ampere Rating Description Catalog Number Wire Range<br />

400 For Fusible LKF4 (1)—3/0-750 kcmil (Cu or Al)<br />

600 Switch LKF6 (2)—3/0-500 kcmil (Cu or Al)<br />

400 For Circuit LKB4 (1)—600-750 kcmil (Cu or Al)<br />

600 Breaker LKB6 (2)—3/0-350 kcmil (Cu or Al)<br />

800 LKB8 (2)—600-750 kcmil (Cu or Al)<br />

Distribution Panel Kits — Discount Schedule SWBD<br />

Ampere<br />

Rating<br />

400<br />

and<br />

600<br />

800<br />

Voltage<br />

120/240V; 1-Phase, 3-Wire<br />

240/120V; 3-Phase, 4-Wire Delta <br />

240V; 3-Phase, 3-Wire <br />

208Y/120V; 3-Phase, 4-Wire<br />

480Y/277V; 3-Phase, 4-Wire<br />

480V; 3-Phase, 3-Wire<br />

120/240V; 1-Phase, 3-Wire<br />

240/120V; 3-Phase, 4-Wire Delta <br />

240V; 3-Phase, 3-Wire<br />

208Y/120V; 3-Phase, 4-Wire<br />

480V; 3-Phase, 3-Wire<br />

480Y/277V; 3-Phase 4-Wire<br />

Number and Type of Breaker Poles<br />

QR2, QRH2,<br />

QP or HQ ED4 or HQR2 <br />

FXD6 <br />

Catalog<br />

Number<br />

30 — — — PQ2630<br />

12 — 12 — PQ2612<br />

30 — — — PQ4630<br />

42<br />

12 — 12 — PQ4612<br />

— 30 — — PE4630 42<br />

— 12 — 6 PF4606 65<br />

40 — — — PQ2840<br />

12 — 16 — PQ2816<br />

65<br />

40 — — — PQ4840<br />

12 — 18 — PQ4818<br />

70<br />

— 40 — — PE4840 65<br />

— 12 — 9 PF4809 70<br />

Weight<br />

39<br />

13 SWITCHBOARDS<br />

Circuit Breaker Subfeed Kits: (Breakers Not Included) — Discount Schedule SWBD<br />

Description<br />

Catalog Number<br />

For FXD6-225A 2 or 3-pole<br />

PSFFJ6<br />

For JXD6, JD6, HJD6 400A 2 or 3-pole<br />

PSFJL6<br />

For inches / millimeters conversion, see conversion table<br />

in Application Data section.<br />

Includes phase and neutral load lugs and neutral link<br />

assembly.<br />

2-pole FXD6 requires 3-pole space.<br />

Includes branch neutral and disconnect link assembly.<br />

1-pole breakers must not be connectedto “B” phase.<br />

2-pole breakers must be rated 240V.<br />

FXD6 circuit breakers are limited to 225A maximum.<br />

Price from Molded Case Circuit Breaker section.<br />

= Warehouse Stock<br />

Product Category SWBD<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 13-19


Stock Service Entrance Switchboards<br />

Super Blue Pennant Switchboards<br />

Revised on 10/31/18<br />

Accessories<br />

Description<br />

Catalog Number<br />

Underground Pull Section or Full Height Section For Load Wiring — Discount Schedule SWBD<br />

14.5" Deep 90" High<br />

14" Wide (12" opening) — indoor PUG14<br />

15" Wide (12" opening) — outdoor WPUG14<br />

26" Wide (24" opening) — indoor PUG26<br />

27" Wide (24" opening) — outdoor WPUG26<br />

10" Wide (load wiring) PLW10<br />

13<br />

Lug Landing Kits — Discount Schedule SWBD (Requires Catalog Number PUG26 or WPUG26)<br />

400A 1-Phase, 3-Wire or 3-Phase, 4-Wire PLL44 a<br />

600A 1-Phase, 3-Wire or 3-Phase, 4-Wire PLL46 a<br />

800A 1-Phase, 3-Wire or 3-Phase, 4-Wire PLL48 a<br />

SWITCHBOARDS<br />

“R” Fuse Clip Adapter Kit (Set of 3) — Discount Schedule VBSS<br />

400A 240/600V<br />

600A 240/600V<br />

“J” Fuse Clip Adapter Kit (Set of 3) — Discount Schedule VBSS<br />

400A 240V<br />

400A 600V<br />

600A 240V<br />

600A 600V<br />

HR65A<br />

HR66A<br />

bc<br />

HJ65A bd<br />

HJ66A bc<br />

HJ66A<br />

“T” Fuse Clip Adapter Kit (One Pole Kit) — Discount Schedule VBSS<br />

400A 240V<br />

400A 600V<br />

600A 240V<br />

600A 600V<br />

HT25A<br />

HT65A, HT265A e<br />

HT26A<br />

HT66A<br />

Optional Meter Sockets and Doors — Discount Schedule SWBD<br />

Meter Compartment Door (32" Wide x 15" High for “S” base socket with<br />

test block cutout (order necessary meter base from items below)<br />

Meter Compartment Door (32" Wide x 30" High) for 2 “S” base<br />

meters with mounting provisions for test block and printing<br />

demand meter (order meter base from table below)<br />

Left Hand Hinge or Right Hand Hinge<br />

Blank Meter Compartment Door (32" Wide x 15" High)<br />

PSP32<br />

PSDP32<br />

PBP32<br />

5 Clip Meter Socket with ring PMS5<br />

6 Clip Meter Socket with ring PMS6<br />

8 Clip Meter Socket with ring PMS8<br />

13 Clip Meter Socket with ring PMS13<br />

15 Clip Meter Socket with ring PMS15<br />

Filler Plates — Discount Schedule MCCB<br />

QP, BL, BQD, xGB, xGB2, ED<br />

Handle Blocking and Padlock Devices — Discount Schedule MCCB<br />

Blocking (QP-HQP 1, 2 and 3-pole)<br />

Blocking (QR2, QRH2, HQR2, HQR2H)<br />

Blocking (ED2, ED4, ED6)<br />

Padlock (QP-HQP)<br />

Padlock (QR2, QRH2, HQR2, HQR2H)<br />

Padlock (ED2, ED4, ED6)<br />

QF3<br />

ECQL1<br />

HBLQR<br />

E2HBL<br />

ECQLD3<br />

HPLQR<br />

ED2HPL<br />

Equipment Ground Bus –– Discount Schedule SWBD<br />

PEGB42<br />

For inches / millimeters conversion, see conversion table<br />

in Application Data section.<br />

= Warehouse Stock<br />

● A suffix. New ‘Series A’ design<br />

aA PUG26 or WPUG26 Underground pull section is<br />

required when using these lug landing kits.<br />

b Kit not required for branch circuit swtiches, relocate lug<br />

base to achieve fuse fit.<br />

c J fuse option not available for 240V main switches.<br />

d Lug base relocation plus kit required for branch circuit<br />

swtiches.<br />

e Kit required for Main Switch only.<br />

13-20<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category SWBD


Stock Service Entrance Switchboards<br />

BCT Service Cubicle<br />

Selection<br />

Product Description<br />

Siemens BCT stock service entrance switchboards are<br />

designed as stock units to meet the fast delivery needs of the<br />

market.<br />

Siemens BCT switchboards incorporate a utility current<br />

transformer compartment and a Sentron molded case circuit<br />

breaker in a single section.<br />

BCT switchboards have many applications, some of the most<br />

common include:<br />

n Retail stores<br />

n Office buildings<br />

n Small factories<br />

n Commercial stores and shopping centers<br />

Features & Benefits<br />

Features<br />

n Up to 1200 amperes<br />

n Up to 600 volts AC<br />

n Bus bracing up to 100KAIC<br />

n Type 1 enclosures only<br />

Utility Provision<br />

The provision can be adjusted for use with 12” or 14.5”<br />

primary bar type current transformers. All switchboards<br />

are supplied as top feed cold sequence metering only.<br />

Switchboards can be field modified for other configurations<br />

per the available configurations table below.<br />

Main Disconnect<br />

The main service disconnect is a Sentron molded case circuit<br />

breaker available from 400 to 1200 amperes.<br />

13 SWITCHBOARDS<br />

Utility metering provsion<br />

Enclosure<br />

The enclosure is tamperproof with a hinged door over the<br />

utility provision compartment with a latch for the utility to<br />

be able to seal off the compartment. Enclosures are only<br />

available as type 1 indoor.<br />

Standards & Certifications<br />

n UL891<br />

n NEMA PB-2<br />

n Other equipment is UL listed as applicable<br />

BCT Service Cubicle<br />

BCT Catalog Numbers & Application Data<br />

Neutral disconnect link<br />

Connectors (Per Phase & Neutral)<br />

Ampere<br />

Rating<br />

Connectors Suitable<br />

For Cu or Al<br />

400 (1) 4/0-500 kcmil<br />

(2) 250 kcmil<br />

600 (2) 4/0-500 kcmil<br />

800 (2) 250-500 kcmil<br />

1000 (4) 250-500 kcmil<br />

1200 (4) 250-500 kcmil<br />

Catalog<br />

Number<br />

Symmetrical Amperes<br />

Interrupting Capacity<br />

Ampere<br />

Rating<br />

Dimensions<br />

(inches)<br />

Available<br />

Configurations<br />

Top Feed Top<br />

Cold Feed<br />

240V 480V 600V System Voltage<br />

Height Width Depth Seq. Hot Seq.<br />

BCT436JXD6 65,000 35,000 25,000<br />

● ● ●<br />

400 120/240V 1-Phase, 3-Wire<br />

BCT436HJD6 100,000 65,000 35,000 ● ●<br />

208Y/120V 3-Phase, 4-Wire 70<br />

BCT636LXD6 65,000 35,000 25,000<br />

240V 3-Phase, 3-Wire<br />

● ● ●<br />

600<br />

BCT636HLD6 100,000 65,000 35,000 480Y/277V 3-Phase, 4-Wire<br />

● ●<br />

BCT836MXD6 65,000 50,000 25,000<br />

480V 3-Phase, 3-Wire<br />

● ● ●<br />

800 600V 3-Phase, 3-Wire<br />

32 13.75<br />

BCT836HMD6 100,000 65,000 50,000 ●<br />

BCT1036NXD6 65,000 — —<br />

● ● ●<br />

1000<br />

90<br />

BCT1036HND6 100,000 — — 208Y/120V 3-Phase, 4-Wire<br />

●<br />

BCT1236NXD6 65,000 — —<br />

1200<br />

240V 3-Phase, 4-Wire<br />

● ● ●<br />

BCT1236HND6 100,000 — — ●<br />

PTE Potential Transformer Enclosure — — — 20 20 10<br />

Bottom Feed<br />

Cold / Hot<br />

Seq.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 13-21


Stock Service Entrance Switchboards<br />

SCT Service Cubicle<br />

Selection<br />

Product Description<br />

Siemens SCT stock service entrance switchboards are<br />

designed as stock units to meet the fast delivery needs of the<br />

market.<br />

Siemens SCT switchboards incorporate a utility current<br />

transformer compartment and a Vacu-Break fusible switch.<br />

Features & Benefits<br />

Features<br />

n Up to 1200 amperes<br />

n Up to 600 volts AC<br />

n Bus bracing up to 200KAIC<br />

n Type 1 enclosures only<br />

13<br />

SWITCHBOARDS<br />

SCT switchboards have many applications, some of the most<br />

common include:<br />

n Retail stores<br />

n Office buildings<br />

n Small factories<br />

n Commercial stores and shopping centers<br />

Utility Provision<br />

The provision can be adjusted for use with 12” or 14.5”<br />

primary bar type current transformers. All switchboards are<br />

supplied as top feed cold sequence metering only..<br />

Main Disconnect<br />

The main service disconnect is a Vacu-Break fusible switch<br />

available from 400 to 1200 amperes.<br />

Enclosure<br />

The enclosure is tamperproof with a hinged door over the<br />

utility provision compartment with a latch for the utility to<br />

be able to seal off the compartment. Enclosures are only<br />

available as type 1 indoor.<br />

Standards & Certifications<br />

n UL891<br />

n NEMA PB-2<br />

n Other equipment is UL listed as applicable<br />

Connectors (Per Phase & Neutral)<br />

SCT Service Cubicle<br />

SCT Catalog Numbers & Application Data<br />

Vacu-Break Main Switch<br />

Ampere<br />

Rating<br />

Connectors Suitable<br />

For Cu or Al<br />

400 (1) 4/0-500 kcmil<br />

(2) 250 kcmil<br />

600 (2) 4/0-500 kcmil<br />

800 (2) 250-500 kcmil<br />

1000 (4) 250-500 kcmil<br />

1200 (4) 250-500 kcmil<br />

Fuse Clips<br />

Ampere<br />

Rating<br />

Fuse<br />

Clip<br />

400 - 600 R 200,000<br />

800 - 1200 L 100,000<br />

Symmetrical Amperes<br />

Interrupting Capacity<br />

Catalog Number<br />

Ampere<br />

Dimensions (inches)<br />

Cold Sequence Hot Sequence Rating System Voltage<br />

Height Width Depth<br />

SCT432 LSCT432 400 120/240V 1-Phase, 3-Wire<br />

SCT632 LSCT632 600 208Y/120V 240V 3-Phase, 4-Wire 3-Phase, 3-Wire<br />

SCT436 LSCT436 400 480Y/277V 3-Phase, 4-Wire<br />

SCT636 LSCT636 600 480 or 600V 3-Phase, 3-Wire<br />

90 32 20<br />

SCT836 LSCT836 800 All —<br />

SCT1236 LSCT1236 1200 208Y/120V 240V 3-Phase, 4-Wire 3-Phase, 3-Wire<br />

13-22<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Switchboard Monitoring<br />

Sm@rtGear Mobile App<br />

Take control of your gear<br />

from your smart device<br />

Remotely monitor, configure, and control using<br />

mobile phone or tablet (wireless or hardwired)<br />

Switchgear<br />

Revised on 06/30/19<br />

Switchboard<br />

Selection<br />

Arc flash safety<br />

n Remotely open/close breakers from outside arc<br />

flash hazard zone – no longer need dedicated<br />

control panel<br />

n Remotely activate breaker maintenance mode<br />

from outside arc flash hazard zone<br />

n Remotely view breaker status from outside arc<br />

flash hazard zone<br />

Ease of commissioning<br />

n Set breaker settings via touchscreen using mobile<br />

phone or tablet<br />

13 SWITCHBOARDS<br />

Security<br />

n Local security enabled WPA2 WIFI network only<br />

allowing local access<br />

MindSphere (IoT) capable<br />

Intelligence and control at your fingertips<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 13-23


Switchboard Monitoring<br />

Sm@rtGear Mobile App<br />

Revised on 06/30/19<br />

Selection<br />

Sm@rtGear Mobile Network Topology<br />

Wireless<br />

Mobile Devices Running Siemens Sm@rt Mobile App<br />

Hardwire<br />

Mobile Devices Running Siemens Sm@rt Mobile App<br />

13<br />

SWITCHBOARDS<br />

Network<br />

Switch<br />

— Ethernet<br />

— ULP<br />

Network<br />

Switch<br />

Smart<br />

DAS<br />

Local<br />

Server<br />

Smart<br />

DAS<br />

Local<br />

Server<br />

Wireless<br />

Router<br />

Modbus<br />

Gateway<br />

Modbus<br />

Gateway<br />

WL/VL Electronic Trip Unit<br />

ETU<br />

Power Meter<br />

SEM3 Modular<br />

Metering<br />

WL/VL Electronic Trip Unit<br />

ETU<br />

Power Meter<br />

SEM3 Modular<br />

Metering<br />

Sm@rtGear Mobile Standard Features<br />

n Available in Type WL LV Switchgear, SB Switchboards and<br />

P4/P5 Power Panelboard<br />

n Integrates with Siemens application using phone or tablet<br />

n Ethernet switch and WIFI access point with WPA2 encryption<br />

Power/Insulated Case Circuit Breaker Feature<br />

n ETU 776 with Sm@rt Dynamic Arc Sentry (DAS)<br />

n MODBUS communication<br />

n Protective settings and alarm functions<br />

n Current and voltage monitoring<br />

n Power metering functions<br />

n Electrically operated breakers<br />

n Remote open/close<br />

Molded Case Circuit Breaker Features<br />

n ETU 586 with Smart DAS<br />

n MODBUS communication<br />

n Protective settings and alarm functions<br />

n Current monitoring<br />

n Breaker status<br />

Sm@rtGear Mobile Optional Features<br />

n PAC Digital meter integration<br />

n SEM3 submetering integration<br />

n Siemens MindSphere IoT integration<br />

13-24<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Switchboard Replacement Parts & Modification Kits<br />

Replacement Information, Accessories & Modifications<br />

Revised on 04/30/19<br />

Selection<br />

Connection Strap Kits - Circuit Breaker <br />

For use with SB1, SB2, SB3, FC20, FCI, FCII, CDP-6 & VB-6<br />

switchboards or series 5 or 6 CDP circuit breaker panelboards.<br />

Includes straps, cover plates and necessary hardware for<br />

switchboards manufactured since 1974. For replacement strap<br />

kits for RCIII switchboards, contact your local sales office.<br />

Connection Strap Kits - Vacu-Break & HCP <br />

For use with SB1, SB2, SB3, FC20, FCI, FCII, VB-5 & VB-6<br />

switchboards. Includes straps, cover plates and necessary<br />

hardware for switchboards manufactured since 1974. For<br />

replacement strap kits for RCIII switchboards, contact your<br />

local sales office.<br />

Max<br />

Amp<br />

Rating<br />

Breaker<br />

Family<br />

Breaker Type<br />

Catalog<br />

Number<br />

Unit<br />

Height<br />

(Inches)<br />

Mounting<br />

100 General BL, BQD SBLBD 3.75 Twin<br />

125 General EB SEBD 3.75 Twin<br />

General xGB SNBD 3.75 Twin<br />

General XGB2 SGB2D 3.75 Twin<br />

General ED 6E62 3.75 Twin<br />

General CED 6CLE2 3.75 Twin<br />

150 VL DG SDGD 5.00 Twin<br />

3VA 3VA61 S3VA52TD b 5.00 Twin<br />

225 General QJ 6QJ2 5.00 Twin<br />

General QR 6QR2 5.00 Twin<br />

250 VL FG SFGD 5.00 Twin<br />

Sentron FD 6F62 5.00 Twin<br />

Sentron CFD 6CLF1 5.00 Single<br />

3VA 3VA52, 3VA62 c S3VA52TD b 5.00 Twin<br />

400 VL JG SJG2D 6.25 Twin<br />

VL JG SJG1D 6.25 Single<br />

Sentron JD 6JJ61 8.75 Single<br />

Sentron JD 6JJ62 8.75 Twin<br />

Sentron CJD 6CLJ1 8.75 Single<br />

Sentron SJD 6SJL1 8.75 Single<br />

Sentron SCJD 6SCJ1 8.75 Single<br />

600 VL LG SLGD 6.25 Single<br />

Sentron LD 6LL61 8.75 Single<br />

Sentron CLD 6CLL1 8.75 Single<br />

Sentron SLD 6SLL1 8.75 Single<br />

Sentron SCLD 6SCL1 8.75 Single<br />

800 VL MG MG1D 8.75 Single<br />

Sentron LMD SLM1D 8.75 Single<br />

Sentron MD SMND 10.00 Single<br />

Sentron SMD SSMND 10.00 Single<br />

1200 VL NG NG1D 10.00 Single<br />

Sentron ND SMND 10.00 Single<br />

Sentron SND SSMND 10.00 Single<br />

3VA Breaker Provision Kits<br />

Breaker Type Catalog Number Description<br />

3VA52, 3VA61 or<br />

3VA62 Breaker<br />

S3VA52PR<br />

Contains the necessary<br />

hardware to land breaker<br />

on an existing strap kit<br />

Switch<br />

Type<br />

Filler Plates <br />

For use with SB1, SB2, SB3, FC20, FCI, FCII, CDP-6 & VB-6<br />

switchboards or series 5 or 6 CDP circuit breaker panelboards.<br />

Includes straps, cover plates and necessary hardware for<br />

switchboards manufactured since 1974. For replacement strap<br />

kits for RCIII switchboards, contact your local sales office.<br />

Breaker Frame<br />

Ampere<br />

Rating<br />

Unit Height<br />

(inches)<br />

Filler Plate<br />

Catalog Number<br />

Catalog<br />

Number<br />

Vacu-Break 30-30 5, 7.5 VB657<br />

30-60 5, 7.5<br />

60-60 5, 7.5<br />

60-100 7.5<br />

100-100 7.5<br />

100 7.5<br />

200 7.5, 10 VB671<br />

200-200 10 VB610<br />

400-600 10, 15 VB6150<br />

HCP 800-1200 16.25 F6162D<br />

Blank Plates - Circuit Breaker & Fusible Switch <br />

For use with SB1, SB2, SB3, FC20, FCI, FCII switchboards or<br />

series 5 or 6 VB and CDP panelboards.<br />

Unit Height (Inches)<br />

Catalog Number<br />

1.25 6FPB01<br />

2.5 6FPB02<br />

3.75 6FPB03<br />

5 6FPB05<br />

10 6FPB10<br />

Notes<br />

BL, BQD, ED, xGB, xGB2 DFFP1 Per Pole<br />

Note: When a front filler plate is not completely filled with<br />

breakers, the openings in the unused space must be closed<br />

with 1-pole filler plates from table.<br />

13 SWITCHBOARDS<br />

For inches / millimeters conversion, see conversion table<br />

Consult sales office for availability<br />

b To field install a single 3VA52, 3VA61 or 3VA62 breaker<br />

to an existing strap, provision kit #S3VA52PR is required.<br />

c 3VA62 breaker will be available in Fall 2019.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 13-25


Switchboard Replacement Parts & Modification Kits<br />

Replacement Information, Accessories & Modifications<br />

Revised on 04/30/19<br />

Selection<br />

Replacement Meter Socket Kits bc<br />

For use with SMM and SMD metering switchboards<br />

Type<br />

1-Phase<br />

3-Phase<br />

Catalog Number<br />

MSK2001<br />

MSK2003<br />

Connecting Kits b<br />

For use with SMM and SMD metering switchboards<br />

13<br />

SWITCHBOARDS<br />

Disconnect Device<br />

NGG<br />

EG<br />

BQ<br />

QR<br />

ED<br />

FD<br />

CED<br />

T-Fuse Pullout<br />

Catalog Number<br />

SMMNGMK<br />

SMMHEMK<br />

SMMBQMK<br />

SMMQRMK<br />

SMMEDMK<br />

SMMFDMK<br />

SMMCEMK<br />

SMMTFMK<br />

Cover Plates<br />

For use with SB1, SB2, SB3, FC20, FCI, FCII, CDP-6 & VB-6<br />

switchboards or series 5 or 6 CDP circuit breaker panelboards.<br />

Breaker Type<br />

QR<br />

Catalog Number<br />

SQRC d<br />

For inches / millimeters conversion, see conversion table<br />

Consult sales office for availability<br />

b Siemens meter socks used in SMM switchboards<br />

c Siemens Type WMS263 Meter Sockets are rated 200A<br />

in application Data Section<br />

d To replace a QJ with a QR only a new cover is needed<br />

up to 225A.<br />

13-26<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Switchgear<br />

SPEEDFAX TM<br />

Section<br />

Type GM-SG Metal-Clad Switchgear<br />

5-MSV Replacement Breaker<br />

Type WL Low voltage<br />

Metal-Enclosed Switchgear<br />

Scan to connect<br />

online to the<br />

most up-todate<br />

version of<br />

this Section of<br />

SPEEDFAX.<br />

c o n t e n t s<br />

Medium-voltage Equipment 14-2 – 14-26<br />

5–15 kV Types GM-SG and GM-SG-AR and<br />

38 kV Type GM38 Metal-Clad Switchgear 14-2 – 14-4<br />

5–15 kV Types GM-SG and GM-SG-AR Switchgear Overview 14-5 – 14-15<br />

Type GM-SG Switchgear 14-5<br />

Arc-Resistant Type GM-SG-AR Switchgear 14-6<br />

Type GMSG Vacuum Circuit Breakers 14-7 – 14-8<br />

Types GM-SG and GM-SG-AR Switchgear Dimensions 14-9 – 14-11<br />

Types GM-SG and GM-SG-AR Switchgear Accessories 14-12 – 14-13<br />

Types GM-SG and GM-SG-AR Switchgear End Views 14-14 – 14-15<br />

38 kV Type GM38 Metal-Clad Switchgear 14-16 – 14-18<br />

38 kV Gas-Insulated Metal-Clad Switchgear 14-19<br />

OEM Component Offering 14-20<br />

5–15 kV SIEBREAK Metal-Enclosed Load-Interrupter Switchgear 14-21<br />

Types SIMOVAC and SIMOVAC-AR MVC up to 7.2 kV 14-22 – 14-25<br />

Motor Protection 14-26<br />

Protective Relays & SCADA Systems 14-27 – 14-33<br />

SCADA/Substation Automation 14-27<br />

SIPROTEC Protective Relays 14-28 – 14-31<br />

Competitor Comparison 14-32 – 14-33<br />

Replacement Breakers & Retrofit Products 14-34 – 14-35<br />

Medium-voltage Replacement Circuit Breakers 14-34<br />

Safety Racking Solutions 14-35<br />

Field Services 14-36 – 14-39<br />

Start-up/Commissioning/Engineer-by-the-Day Services 14-36 – 14-37<br />

Power System Studies 14-38<br />

Arc Flash Study 14-39<br />

Secondary Unit Substations 14-40 – 14-51<br />

Overview 14-40<br />

Type SIEBREAK Metal-Enclosed Load-Interrupter Primary Switch 14-41<br />

Transformers—Dry Type 14-44 – 14-45<br />

Transformers—Liquid-Filled Type 14-46<br />

Type WL Low-voltage Switchgear Substation Secondaries 14-47<br />

Switchboard Substation Secondaries (See Switchboard Section 13) 14-48<br />

Transformer Diagrams 14-49 – 14-51<br />

Low-voltage Switchgear 14-52 – 14-94<br />

Standard WL Low-voltage Switchgear 14-52 – 14-80<br />

Construction Details 14-53 – 14-55<br />

WL Circuit Breakers 14-56, 14-58<br />

Electronic Tripping Units 14-57, 14-59<br />

Technical Information 14-60 – 14-71<br />

Section Configuration/Dimensions 14-73 – 14-80<br />

Sm@rtGear Mobile App 14-81 – 14-82<br />

Sm@rtGear WL Low-voltage Switchgear 14-83 – 14-84<br />

Marine WL Low-voltage Switchgear 14-85<br />

Arc Resistant WL Low-voltage Switchgear 14-86 – 14-88<br />

Arc Flash Solutions 14-89 – 14-94<br />

All statements, technical information and recommendations contained herein are based on information and tests we<br />

believe to be reliable. The accuracy or completeness hereof is not guaranteed. Since conditions of use are outside our<br />

control, the user should determine the suitability of the product for its intended use and assumes all risk and liability<br />

whatsoever in connection herewith.<br />

14 SWITCHGEAR<br />

(Section was last modified on 07/12/19)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-1


Medium-voltage Equipment<br />

5 – 15 kV Types GM-SG and GM-SG-AR and 38 kV Type GM38 Metal-Clad Switchgear General<br />

14<br />

SWITCHGEAR<br />

Overview<br />

Siemens 5, 7.2, 15 and 38 kV class<br />

medium-voltage, one- or two-high<br />

vacuum circuit breaker switchgear is of<br />

the Metal-Clad type as covered by<br />

ANSI/IEEE standard C37.20.2. All<br />

parts are completely enclosed within<br />

grounded metal barriers. Circuit<br />

breakers are the horizontal drawout<br />

type. Secondary control devices and<br />

primary circuits are isolated from each<br />

other by shutters or barriers. Primary<br />

circuits of different potential are also<br />

separated by barriers. All primary bus<br />

work and joints are completely encased<br />

with insulation material to suit the<br />

voltage class of the equipment.<br />

Single Source Responsibility<br />

Single source responsibility is assured<br />

since the complete equipment<br />

is designed by Siemens and is<br />

manufactured and tested in a single<br />

facility. The vacuum circuit breakers are<br />

checked in the switchgear cells as part<br />

of production testing, and to assure<br />

interchangeability.<br />

Features<br />

Siemens Type 3AH3 Operating<br />

Mechanism<br />

The types GMSG and 38-3AH3<br />

circuit breakers use the proven<br />

Siemens type 3AH3 stored-energy<br />

operating mechanism. This operator<br />

is an evolution of the type 3A family<br />

of operators first introduced in 1976.<br />

Over 120,000 type 3AH3 operating<br />

mechanisms have been produced since<br />

1998.<br />

Faster Interruption<br />

Standard interrupting time is five-cycles<br />

with an option available for three-cycle<br />

interrupting time.<br />

Floor Rollout<br />

No lift truck or dolly is needed to insert<br />

or remove circuit breakers in the lower<br />

cell of the switchgear located at floor<br />

level. For indoor switchgear located<br />

on a raised housekeeping pad or for<br />

outdoor, non-walk-in switchgear, a<br />

lift truck is required to handle circuit<br />

breakers or drawout fuse trucks.<br />

Closed Door Racking<br />

The circuit breaker can be racked in or<br />

out with the cell door open or closed.<br />

The mechanism includes an indicator to<br />

show the racking mechanism position<br />

with the door closed. For racking, a<br />

manual drive crank or an optional electric<br />

motor drive may be used.<br />

Automatic Shutters<br />

Automatically operated grounded steel<br />

shutters are included to allow or block<br />

access to the stationary primary<br />

disconnects. The shutters are opened<br />

by the circuit breaker as it moves<br />

toward the connected position. The<br />

shutters close as the circuit breaker<br />

is racked away from the connected<br />

position. The shutters remain closed<br />

until they are forced open by insertion<br />

of the circuit breaker. This design<br />

enhances protection for personnel<br />

compared to shutters that are linked to<br />

the racking mechanism.<br />

5 through 15 kV Available in One- or<br />

Two-High Design<br />

38 kV Available in One-High Design<br />

Only<br />

Tested to ANSI/IEEE Standards<br />

Siemens switchgear is tested to meet<br />

the requirements of ANSI/IEEE<br />

standards. A complete design test program<br />

including short-circuit interruption, loadcurrent<br />

switching, continuous current,<br />

mechanical endurance, close and latch<br />

current, short time and momentary<br />

withstand, impulse withstand, and the<br />

other tests required by the standards<br />

has been successfully completed.<br />

These tests encompass the complete<br />

equipment design, including both the<br />

switchgear structure and the circuit<br />

breaker removable element. Certified<br />

test data can be furnished to customers<br />

upon request.<br />

UL or C-UL Listing<br />

When specified, if the component<br />

configuration allows, the switchgear can<br />

be provided with the UL or C-UL (for<br />

use in Canada) Listed label, indicating<br />

conformance to the requirements<br />

of ANSI/IEEE C37.54 and ANSI/IEEE<br />

C37.55.<br />

Quality Systems<br />

Facilities involved with application,<br />

engineering, design and production are<br />

certified to ISO 9001 requirements.<br />

Siemens Relays, see Relaying section<br />

on page 14-28<br />

Type GM-SG 5 - 15 kV Metal-Clad Switchgear<br />

Type GM38 38 kV Metal-Clad Switchgear<br />

14-2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Medium-voltage Equipment<br />

5 – 15 kV Types GM-SG and GM-SG-AR and 38 kV Type GM38 Metal-Clad Switchgear General<br />

Siemens types GM-SG and GM-SG-<br />

AR 5, 7.2 and 15 kV and type GM38<br />

38 kV metal-clad power switchgear<br />

assemblies with horizontal drawout<br />

vacuum circuit breakers take advantage<br />

of the latest developments in vacuum<br />

interrupter technology. Up to two circuit<br />

breakers can be stacked in a single<br />

vertical section, allowing significant<br />

space savings in the types GM-SG and<br />

GM-SG-AR switchgear. In the type<br />

GM38 switchgear, circuit breaker are<br />

available only in the lower compartment.<br />

The equipment meets or exceeds the<br />

latest standards of ANSI, IEEE and<br />

NEMA.<br />

Types GM-SG, GM-SG-AR and<br />

GM38 switchgear are designed for<br />

use in industrial plants, commercial<br />

buildings, electric utility systems,<br />

cogeneration installations and other<br />

electrical systems. It is commonly<br />

used for protection and switching of<br />

transformers, motors, generators,<br />

capacitors, buses, distribution feeder<br />

lines and, in general, for protection of<br />

any medium-voltage power circuit.<br />

Siemens’ experience gained in over 80<br />

years of supplying metal-clad switchgear<br />

in the U.S. has been captured in the<br />

switchgear designs. The objective has<br />

been to incorporate features designed<br />

to provide safety, while simplifying<br />

operation and maintenance, and<br />

minimizing installation cost.<br />

The switchgear structure and the<br />

drawout vacuum circuit breaker are<br />

an integrated design, with dielectric,<br />

thermal and interruption integrity built<br />

directly into the basic design, not added<br />

as an afterthought.<br />

Siemens Vacuum Interrupters<br />

The vacuum interrupters used in the<br />

types GMSG and 38-3AH3 circuit<br />

breakers are manufactured by Siemens<br />

and have been proven in thousands of<br />

installations since 1976. The chromecopper<br />

contact design used in these<br />

vacuum interrupters assures low<br />

chopping levels, eliminating the need<br />

for surge protection on most circuits.<br />

Front Mounted Operating<br />

Mechanism<br />

The simple type 3AH3 operating<br />

mechanism makes maintenance and<br />

inspection easy. The mechanism is<br />

located on the front of the circuit<br />

breaker, rather than underneath.<br />

Maintenance Intervals<br />

If applied under ANSl “usual service”<br />

conditions, maintenance of the circuit<br />

breaker mechanism is only needed at<br />

10-year intervals for type GMSG circuit<br />

breakers and at five-year intervals for<br />

type 38-3AH3 circuit breakers.<br />

Maintenance of the switchgear cubicle<br />

is recommended at five-year intervals,<br />

and primarily consists of cleaning<br />

insulation.<br />

“Universal” Spare Circuit Breaker<br />

The physical configuration and interlock<br />

logic allow the use of a single circuit<br />

breaker to serve as a “universal” spare<br />

breaker at an installation site for up to<br />

50 kA for type GM-SG or type GM-SG-<br />

AR, or for up to 40 kA in type GM38<br />

switchgear. The universal spare breaker<br />

(63 kA) type GMSG vacuum circuit<br />

breaker is designed such that a circuit<br />

breaker can be installed in any type<br />

GM-SG circuit breaker cell rated 63 kA.<br />

Circuit breakers rated 63 kA cannot<br />

be used in equipment rated 50 kA<br />

and lower. The interlock logic checks<br />

the principal rating characteristics<br />

(continuous current, maximum voltage,<br />

and interrupting current), and allows<br />

a circuit breaker to be inserted in any<br />

circuit breaker cell, provided that the<br />

circuit breaker equals or exceeds the<br />

ratings required by the cell.<br />

Full ANSI and IEEE Design<br />

Background<br />

Full design integrity is assured. ANSl<br />

C37.09 and C37.20.2 require design<br />

tests on circuit breakers and structures<br />

together. The 3AH3 operator design<br />

is controlled in our global center<br />

of competence for circuit breakers<br />

in Berlin, and final assembly of both<br />

the drawout circuit breaker and the<br />

switchgear structures occurs in a<br />

single facility. Siemens controls the<br />

entire process, from design concept to<br />

production. Records are maintained to<br />

document compliance with ANSl/IEEE<br />

standards.<br />

14 SWITCHGEAR<br />

4,000 A Rating (5 – 15 kV)<br />

Designs are available to 3000A selfcooled,<br />

and 4,000 A fan cooled.<br />

3,000 A Rating (38 kV)<br />

Designs are available to 2,000 A selfcooled<br />

and 3,000 A fan cooled.<br />

Type GM-SG Circuit Breaker Cell Interior<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-3


Medium-voltage Equipment<br />

5 – 15 kV Types GM-SG and GM-SG-AR and 38 kV GM38 Metal-Clad Switchgear General<br />

Type GM-SG Circuit Breaker Cell (1,200 A or 2,000 A<br />

with VT Auxiliary (3,000 A Similar Except Upper Cell<br />

Reserved for Fan-Cooling Equipment)<br />

1<br />

2<br />

12<br />

The type GM-SG-AR arc-resistant design offers significant<br />

flexibility compared to the design of other suppliers. The sidemounted,<br />

arc duct design for the type GM-SG-AR allows the<br />

same flexibility as the type GM-SG non-arc resistant design<br />

for mounting voltage transformers, a drawout control power<br />

transformer and fuse roll-out trays.<br />

14<br />

SWITCHGEAR<br />

3<br />

4<br />

5 2<br />

2<br />

2<br />

11<br />

8<br />

11<br />

8<br />

8 10<br />

6 7<br />

7<br />

9<br />

Siemens type GM38 metal-clad switchgear provides enhanced<br />

flexibility in locating circuit breaker, auxiliary and metering cells<br />

within the structure layout. Circuit breakers are located in the<br />

lower cell positions. The upper cell position can be used for<br />

voltage transformers with the associated drawout primary fuses.<br />

Each vertical section contains the main bus bar compartment,<br />

plus a rear compartment for incoming and outgoing connections.<br />

The front portion of the vertical section contains a lower cell<br />

for circuit breaker, auxiliary devices, VTs, CPT (if primary fuses<br />

are located in upper cell) or drawout primary fuses for a CPT<br />

located in the rear of the section.<br />

Instruments, protective relays and power meters along with<br />

their secondary wiring and other components are located in<br />

the upper cell. The switchgear is normally designed so that<br />

additional vertical sections may be added in the future.<br />

1 Upper type GMSG circuit breaker<br />

2 Standard accuracy current<br />

transformers (CTs)-two per<br />

bushing<br />

3 Isolated protective relay and<br />

instrument compartment<br />

4 Inter-unit wiring<br />

5 Lower type GMSG circuit breaker<br />

6 Ground bar<br />

7 Ground sensor CT<br />

8 Main bus bars<br />

9 Power cable duct<br />

10 Removable barrier<br />

11 Surge arresters<br />

12 Outgoing cable lugs<br />

(downfeed shown)<br />

Structural Flexibility for Types GM-SG and GM-SG-AR<br />

Siemens metal-clad switchgear provides enhanced flexibility<br />

in locating circuit breaker, auxiliary, and metering cells within<br />

the structure layout. Circuit breakers rated 1,200 A and<br />

2,000 A may be located in upper or lower cell positions.<br />

Bus sectionalizing (tie) circuit breaker cells may be located on<br />

the upper or lower levels and are located next to an auxiliary<br />

cell on the same level for the transition bus work.<br />

The types GM-SG and GMSG-AR offer significant flexibility for<br />

stacking breakers. See page 14-12 for more information. The<br />

3,000 A circuit breaker can be used for 4,000 A continuous<br />

current applications, with the addition of fan cooling equipment<br />

in the auxiliary cell above or below the circuit breaker. This<br />

application of fan cooling is well suited if loads above 3,000 A<br />

are infrequent, as for example, in the case of a fan-cooled<br />

rating on a power transformer.<br />

Enclosure Design<br />

The switchgear designs include full ANSI/IEEE C37.20.2<br />

Metal-Clad construction. This means complete enclosure of<br />

all live parts and separation of major portions of the circuit to<br />

retard the spread of faults to other compartments.<br />

The type GM-SG-AR design includes full ANSI/IEEE C37.20.7-<br />

2007, accessibility type 2B. The ground bus extends the entire<br />

length of the complete switchgear lineup, and to all circuit<br />

breaker cells.<br />

Exhaust System for Type GM-SG-AR<br />

The top-mounted pressure relief channel (PRC) is factoryinstalled<br />

for reduced installation time. An outlet from the<br />

switchgear room is supplied with each lineup of equipment.<br />

Circuit Breaker Interchangeability<br />

The switchgear cubicle and the removable circuit breaker<br />

element are both built to master fixtures so circuit breakers<br />

of the same ratings are interchangeable with each other<br />

even if the circuit breaker is required for use with a cell with<br />

“provisions only” supplied years earlier. A circuit breaker of<br />

higher rating can be used in a cell of equal or lower rating.<br />

The GMSG circuit breaker is not interchangeable with the<br />

older designs. 63 kA rated type GMSG circuit breakers can<br />

only be used in 63 kA rated cells and lower rated circuit<br />

breakers cannot be used in 63 kA rated cells. The type<br />

38-3AH3 circuit breaker is interchangeable with the type<br />

38-3AF circuit breaker, provided the ratings are equal. The<br />

type 38-3AF circuit breaker is not interchangeable with the<br />

40 kA type 38-3AH3.<br />

14-4<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Medium-voltage Equipment<br />

Medium-voltage Type GM-SG Switchgear<br />

General<br />

5, 7.2 and 15 kV Drawout Metal-Clad Indoor Switchgear up to 63 kA<br />

n One-high or two-high construction<br />

n Up to 100 full-fault interruptions<br />

n Universal spare circuit breaker for<br />

50 kA and lower ratings<br />

n Universal spare circuit breaker for<br />

63 kA ratings<br />

n Interlocks permit insertion of higher<br />

rated vacuum circuit breaker into<br />

lower rated cell but not vice versa<br />

n Front accessible circuit breaker<br />

operating mechanism for ease of<br />

maintenance<br />

n Closed door racking<br />

n Floor rollout circuit breaker in lower<br />

cell without a dolly<br />

n Visible secondary disconnect<br />

n Circuit breaker ships inside of cell,<br />

thus reducing installation cost and<br />

transit damage<br />

n Pair with Siemens protective relays to<br />

match any typical application<br />

n Horizontal drawout type GMSG<br />

vacuum circuit breaker with type<br />

3AH3 operating mechanism<br />

n Uses the latest developments in<br />

vacuum interrupter technology<br />

n Highly reliable vacuum interrupters -<br />

MTTF over 57,000 years<br />

n Common type 3AH3 operator<br />

platform for all ratings<br />

n Over 120,000 type 3AH3 operators<br />

produced since 1998<br />

n Generator circuit breakers (to IEEE<br />

C37.013 optionally available)<br />

n 10,000 operations to overhaul<br />

n Three-cycle interrupting time<br />

(optional)<br />

n Meets or exceeds the latest ANSI,<br />

IEEE and NEMA standards<br />

n UL or C-UL Listing available<br />

14 SWITCHGEAR<br />

Type GMSG circuit breaker ratings constant kA basis - ANSI/IEEE C37.06-2009<br />

Historic<br />

“MVA” class<br />

Maximum<br />

design<br />

voltage kV<br />

Rated<br />

interrupting<br />

rating kA<br />

Maximum<br />

interrupting and<br />

short-time kA<br />

Voltage<br />

range<br />

factor Continuous current Insulation levels dielectric Close & latch (kA)<br />

rms Peak<br />

60 Hz BIL<br />

1.55 KI 2.6 KI<br />

— 4.76 40 40 1.0 1,200, 2,000, 3,000 19 60 62 104<br />

— 4.76 50 50 1.0 1,200, 2,000, 3,000 19 60 78 130<br />

— 4.76 63 63 1.0 1,200, 2,000, 3,000 19 60 98 164<br />

— 8.25 40 40 1.0 1,200, 2,000, 3,000 36 95 62 104<br />

— 15.0 25 25 1.0 1,200, 2,000 36 95 39 65<br />

— 15.0 40 40 1.0 1,200, 2,000, 3,000 36 95 62 104<br />

— 15.0 50 50 1.0 1,200, 2,000, 3,000 36 95 78 130<br />

— 15.0 63 63 1.0 1,200, 2,000, 3,000 36 95 98 164<br />

4,000 A fan-cooled available using a 3,000 A circuit breaker together with a modified<br />

switchgear structure incorporating fan cooling equipment.<br />

Type GM-SG switchgear available as:<br />

n Indoor (type GM-SG)<br />

n Outdoor non-walk-in (type OGM-SG)<br />

n Outdoor walk-in Shelter-Clad (type SGM-SG)<br />

n Single-aisle<br />

n Factory insulated and assembled aisle (optional).<br />

n Available with SIERS - Siemens Integrated Electric-Racking System<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-5


Medium-voltage Equipment<br />

Arc-Resistant Type GM-SG-AR Switchgear<br />

General<br />

5, 7.2 and 15 kV Drawout Metal-Clad Arc-Resistant Indoor Switchgear up to 63 kA<br />

14<br />

SWITCHGEAR<br />

n Arc-resistant to IEEE C37.20.7, up to<br />

63 kA, 0.5 sec, accessibility type 2B<br />

n Application flexible exhaust system<br />

n Top-mounted pressure relief<br />

channel factory-installed for reduced<br />

installation time<br />

n One-high or two-high construction<br />

n Up to 100 full-fault interruptions<br />

n Universal spare circuit breaker<br />

n Interlocks permit insertion of higher<br />

rated vacuum circuit breaker into<br />

lower rated cell but not vice versa<br />

n Front accessible circuit breaker<br />

operating mechanism for ease of<br />

maintenance<br />

n Closed-door racking<br />

n Floor rollout circuit breaker in lower<br />

cell without a dolly<br />

n Visible secondary disconnect<br />

n Circuit breaker ships inside of cell,<br />

thus reducing installation cost and<br />

transit damage<br />

n Instrumentation/controls located in a<br />

separate compartment isolated from<br />

all primary circuit elements<br />

n Pair with Siemens protective relays<br />

to match any typical application<br />

n Horizontal drawout type GMSG<br />

vacuum circuit breaker with type<br />

3AH3 operating mechanism<br />

n Uses the latest developments in<br />

vacuum interrupter technology<br />

n Highly reliable vacuum interrupters -<br />

MTTF over 57,000 years<br />

n Common type 3AH3 operator<br />

platform for all ratings<br />

n Over 120,000 type 3AH3 operators<br />

produced since 1998<br />

n 10,000 operations to overhaul<br />

n Three-cycle interrupting time<br />

(optional)<br />

n Meets or exceeds the latest ANSI,<br />

IEEE and NEMA standards<br />

n UL or C-UL Listing available<br />

Type GMSG circuit breaker ratings constant kA basis - ANSI/IEEE C37.06-2009<br />

Historic<br />

“MVA” class<br />

Maximum<br />

design<br />

voltage kV<br />

Rated<br />

interrupting<br />

rating kA<br />

Maximum<br />

interrupting and<br />

short-time kA<br />

4,000 A fan-cooled available using a 3,000 A circuit breaker together with a modified<br />

switchgear structure incorporating fan cooling equipment.<br />

Voltage<br />

range<br />

factor Continuous current Insulation levels dielectric Close & latch (kA)<br />

rms Peak<br />

60 Hz BIL<br />

1.55 KI 2.6 KI<br />

— 4.76 40 40 1.0 1,200, 2,000, 3,000 19 60 62 104<br />

— 4.76 50 50 1.0 1,200, 2,000, 3,000 19 60 78 130<br />

— 4.76 63 63 1.0 1,200, 2,000, 3,000 19 60 98 164<br />

— 8.25 40 40 1.0 1,200, 2,000, 3,000 36 95 62 104<br />

— 15.0 25 25 1.0 1,200, 2,000 36 95 39 65<br />

— 15.0 40 40 1.0 1,200, 2,000, 3,000 36 95 62 104<br />

— 15.0 50 50 1.0 1,200, 2,000, 3,000 36 95 78 130<br />

— 15.0 63 63 1.0 1,200, 2,000, 3,000 36 95 98 164<br />

Type GM-SG-AR<br />

switchgear available as:<br />

n Indoor (Type GM-SG-AR)<br />

n Outdoor walk-in Shelter-Clad (Type SGM-SG-AR)<br />

n Single-aisle<br />

n Factory insulated and assembled aisle (optional).<br />

14-6<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Medium-voltage Equipment<br />

Type GMSG Vacuum Circuit Breakers<br />

General<br />

Type GMSG Vacuum Circuit Breakers 5, 7.2 and 15 kV<br />

Siemens type GMSG circuit breakers are available in 25 kA<br />

through 63 kA “constant kA” interrupting classes, or<br />

250 MVA through 1,000 MVA on the older “constant MVA”<br />

rating basis. Continuous current ratings include 1,200 A,<br />

2,000 A, and 3,000 A self-cooled. 4,000 A is available using a<br />

3,000 A circuit breaker together with forced-air (fan) cooling<br />

and larger conductors in the switchgear cubicle.<br />

Maintenance Features<br />

Type GMSG circuit breakers incorporate many features<br />

designed to reduce and simplify maintenance, including:<br />

n Low maintenance vacuum interrupter<br />

n Ten-year maintenance interval (assuming ANSI “usual<br />

service” conditions)<br />

n Floor rollout<br />

n Front-mounted operator<br />

n Common operator family<br />

n Simple outer-phase barriers<br />

n “Universal” spare circuit breaker concept<br />

n Non-sliding current transfer<br />

n Rugged secondary disconnects.<br />

Ten-Year Maintenance Interval on type GMSG Circuit<br />

Breaker<br />

When applied under mild conditions (ANSI “usual service”<br />

conditions), maintenance is typically needed at ten-year<br />

intervals on the circuit breaker. The maintenance interval for<br />

the switchgear cubicles is five years.<br />

Low-Maintenance Requirements<br />

The vacuum interrupter is a sealed unit, so the only<br />

maintenance necessary is to clean off any contaminants and<br />

to check the vacuum integrity. The vacuum interrupters can<br />

be disconnected from the stored-energy mechanism quickly,<br />

without tools, and vacuum integrity inspected by hand;<br />

alternatively, a simple high-potential test can be used.<br />

Floor Rollout<br />

When located in the lower cell, the circuit breakers are<br />

arranged to rollout directly on the floor in front of the<br />

switchgear if the switchgear is not located on a<br />

“housekeeping” pad. No adapter, hoist, or lift truck is<br />

necessary.<br />

14 SWITCHGEAR<br />

Front Side (barriers removed) Rear<br />

Type GMSG Circuit Breaker<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-7


Medium-voltage Equipment<br />

Type GMSG Vacuum Circuit Breaker Ratings<br />

Selection<br />

Type GMSG and GM-SG-AR Circuit Breaker Ratings (New “Constant kA” Ratings Basis)<br />

These ratings are in accordance with the following standards:<br />

n ANSI/IEEE C37.04-1999 Standard Rating Structure for AC High-Voltage Circuit Breakers<br />

n ANSI C37.06-2009 AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis - Preferred Ratings and Related<br />

Required Capabilities for Voltages Above 1,000 Volts<br />

n ANSI/IEEE C37.09-1999 Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis<br />

n ANSI/IEEE C37.010-1999 Application Guide for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis<br />

Circuit Breaker Type a<br />

Rated Values<br />

Units<br />

5-GMSG-<br />

40-<br />

xxxx-104<br />

5-GMSG-<br />

50-<br />

xxxx-130<br />

5-GMSG-<br />

63-<br />

xxxx-164<br />

7-GMSG-<br />

40-<br />

xxxx-104<br />

15-GMSG-<br />

25-<br />

xxxx-65<br />

15-GMSG-<br />

40-<br />

xxxx-104<br />

15-GMSG-<br />

50-<br />

xxxx-130<br />

15-GMSG-<br />

63-<br />

xxxx-164<br />

Maximum Design Voltage (V) b kV rms 4.76 4.76 4.76 8.25 15.0 15.0 15.0 15.0<br />

14<br />

SWITCHGEAR<br />

Voltage Range Factor (k) c — 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0<br />

Withstand<br />

Voltage Levels<br />

Power<br />

Frequency<br />

Lightning<br />

Impulse (BIL)<br />

kV rms 19 19 19 36 36 36 36 36<br />

kV crest 60 60 60 95 95 95 95 95<br />

Continuous d<br />

A rms<br />

1,200<br />

2,000<br />

3,000<br />

4,000FC<br />

1,200<br />

2,000<br />

3,000<br />

4,000FC<br />

1,200<br />

2,000<br />

3,000<br />

4,000FC<br />

1,200<br />

2,000<br />

3,000<br />

4,000FC<br />

1,200<br />

2,000<br />

1,200<br />

2,000<br />

3,000<br />

4,000FC<br />

1,200<br />

2,000<br />

3,000<br />

4,000FC<br />

1,200<br />

2,000<br />

3,000<br />

4,000FC<br />

Short-Circuit (I) ef kA rms sym 40 50 63 40 25 40 50 63<br />

Interrupting Time g<br />

ms<br />

cycles<br />

83<br />

5<br />

83<br />

5<br />

83<br />

5<br />

83<br />

5<br />

83<br />

5<br />

83<br />

5<br />

83<br />

5<br />

83<br />

5<br />

Permissible Tripping Delay (y) Sec 2 2 2 2 2 2 2 2<br />

Maximum Symmetrical<br />

Interrupting (I)<br />

kA rms sym 40 50 63 40 25 40 50 63<br />

% dc Component % 47 47 47 47 47 47 47 47<br />

Short-Time Current (I)<br />

(Three Seconds)<br />

Closing and Latching<br />

(Momentary)<br />

Asymmetrical<br />

(1.55 x I)<br />

kA rms 40 50 63 40 25 40 50 63<br />

kA rms 62 78 98 62 39 62 78 98<br />

Closing and Latching<br />

(Momentary)<br />

Peak<br />

(2.6 x I)<br />

kA peak 104 130 164 104 65 104 130 164<br />

a “xxxx” in type designation refers to the continuous current rating 1,200 A, 2,000 A,<br />

or 3,000 A, as appropriate. The 4,000 A fan-cooled rating is achieved using a 3,000 A<br />

circuit breaker, in combination with fan cooling as indicated in Footnote 4.<br />

b Maximum design voltage for which the circuit breaker is designed, and the upper<br />

limit for operation.<br />

c K is listed for informational purposes only. For circuit breakers rated on a “constant<br />

kA basis”, the voltage range factor is 1.0.<br />

d 4,000FC indicates that fan cooling is included in the switchgear structure for this<br />

rating. 4,000 A rating is not available in outdoor equipment.<br />

e All values apply to polyphase and line-to-line faults.<br />

f Standard duty cycle is O - 0.3s - CO - 3 min. - CO.<br />

g Standard rated interrupting time is five cycles (83 ms)/Optional rated interrupting<br />

time of three cycles (50 ms) 63 kA is available (except with 24 Vdc tripping).<br />

14-8<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Medium-voltage Equipment<br />

Types GM-SG and GM-SG-AR Switchgear<br />

Dimensions<br />

Cubicle Dimensions Per Vertical Section ac<br />

Type<br />

Dimensions in Inches (mm)<br />

Height Width Depth Drawout Aisle<br />

Weight in lbs. (kg) <br />

GM-SG 95.3 (2,419) 36.0 (914) 98.7 (2,507) 72.0 (1,829)<br />

recommended 3,300 (1,497)<br />

SGM-SG 114.8 (2,915) 36.0 (914) 173.4 (4,404) 72.0 (1,829)<br />

included<br />

5,000 (2,268)<br />

OGM-SG 113.6 (2,886) 36.0 (914) 101.9 (2,588) 72.0 (1,829)<br />

recommended 3,950 (1,792)<br />

GM-SG-AR 116.4 (2,957) 40.0 (1,016) 102.8 (2,611) 72.0 (1,829)<br />

recommended 4,100 (1,864)<br />

SGM-SG-AR 135.6 (3,444) 40.0 (1,016) 179.8 (4,566) 72.0 (1,829)<br />

included<br />

5,900 (2,682)<br />

Dimensions are approximate.<br />

Add 6” (152 mm) to each end of the lineup for aisle extension 12” (304 mm) total.<br />

Dimensions are approximate size of floor footprint.For outdoor equipment, enclosure<br />

overhangs floor frame. Refer to Footnote 5.<br />

If indoor switchgear is installed on a raised housekeeping pad, the pad must not<br />

extend farther than 3” (75 mm) from the front of the switchgear to avoid interference<br />

with the use of the portable lift truck.<br />

Add for roof and enclosure overhang:<br />

• Rear (cable side):<br />

• Non-walk-in: 3.6” (92 mm)<br />

• Shelter-Clad: 3.6” (92 mm).<br />

• Front (drawout side):<br />

• Non-walk-in: 3.7” (94 mm)<br />

• Shelter-Clad: 1.7” (43 mm).<br />

72” (1,829 mm) aisle space recommended allows room for interchange of circuit<br />

breakers. Minimum aisle space required for handling circuit breaker with lift truck is<br />

65” (1,651 mm). Minimum aisle space required if all circuit breakers are at floor level<br />

is 55” (1,397 mm).<br />

Add 9” (229 mm) to length of the lineup for end trims.<br />

The switchgear must have at least 6” (152 mm) horizontal clearance:<br />

• From left and right sides to nearest wall or equipment, and<br />

• From rearmost extension of vents on rear to nearest wall or equipment.<br />

No obstructions permitted within 10” (254 mm) of top of switchgear structure.<br />

Add 4.5” (114 mm) to depth for front and rear doors.<br />

Add 1.0” (25 mm) for GM-SG-AR equipment rated 63 kA.<br />

Add weight of circuit breakers from Table 13.<br />

14 SWITCHGEAR<br />

Type GMSG vacuum circuit breaker weight in lbs (kg) bc<br />

Continuous current A<br />

Circuit breaker type<br />

1,200 2,000 3,000<br />

a Weight is approximate.<br />

Approximate circuit breaker (width x depth x height): 32” (813 mm) x39”<br />

(991 mm) x 36”(914 mm). If packed for shipment separate from<br />

switchgear : 42”(1,067 mm) x 47” (1,194 mm) x 43” (1,092 mm).<br />

Weight estimates are for circuit breaker only. Add 75 lbs (34 kg) if shipped<br />

separately packaged.<br />

5-GMSG-40/5-GMSG-250 440 (200) 650 (295) 665 (302)<br />

5-GMSG-50/5-GMSG-350 455 (206) 665 (302) 670 (304)<br />

5-GMSG-63 809 (368) 819 (372) 824 (375)<br />

7-GMSG-40/7-GMSG-500 455 (206) 665 (302) 675 (306)<br />

15-GMSG-25/15-GMSG-500 430 (195) 640 (290) –<br />

15-GMSG-40/15-GMSG-750 445 (202)) 670 (304) 675 (306)<br />

15-GMSG-50/15-GMSG-1000 460 (209) 675 (306) 680 (308)<br />

15-GMSG-63 819 (372) 829 (377) 834 (379)<br />

5-GMSG-GCB-40/15-GMSG-GCB-40 475 (215) 685 (311) 715 (324)<br />

5-GMSG-GCB-50/15-GMSG-GCB-50 825 (374) 835 (379) 865 (392)<br />

5-GMSG-GCB-63/15-GMSG-GCB-63 875 (397) 900 (408) 930 (427)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-9


Medium-voltage Equipment<br />

Types GM-SG and GM-SG-AR<br />

Stacking Versatility<br />

Stacking versatility<br />

GM-SG non-arc-resistant (up to 63 kA) and GM-SG-AR arc-resistant (up to 50 kA) -<br />

1,200 A<br />

circuit<br />

breaker<br />

A<br />

1,200 A<br />

circuit<br />

breaker<br />

A<br />

Auxiliary<br />

Auxiliary<br />

C<br />

D<br />

1,200 A<br />

circuit<br />

breaker<br />

A<br />

2,000 A<br />

circuit<br />

breaker<br />

A<br />

2,000 A<br />

circuit<br />

breaker<br />

A<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

14<br />

SWITCHGEAR<br />

1,200 A<br />

circuit<br />

breaker<br />

B<br />

Auxiliary<br />

Auxiliary<br />

E<br />

F<br />

1,200 A<br />

circuit<br />

breaker<br />

B<br />

2,000 A<br />

circuit<br />

breaker<br />

B<br />

1,200 A<br />

circuit<br />

breaker<br />

B<br />

2,000 A<br />

circuit<br />

breaker<br />

B<br />

Auxiliary<br />

Auxiliary<br />

C<br />

D<br />

2,000 A<br />

circuit<br />

breaker<br />

A<br />

Vented 7<br />

A<br />

Fan 7<br />

A<br />

3,000 A<br />

circuit<br />

breaker<br />

A<br />

Auxiliary<br />

Auxiliary<br />

C<br />

D<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

2,000 A<br />

circuit<br />

breaker<br />

B<br />

Auxiliary<br />

Auxiliary<br />

E<br />

F<br />

3,000 A 7<br />

circuit<br />

breaker<br />

B<br />

3,000 A 7<br />

circuit<br />

breaker<br />

B<br />

Vented<br />

Auxiliary<br />

E<br />

F<br />

Auxiliary<br />

Auxiliary<br />

E<br />

F<br />

Footnotes for GM-SG non-arc-resistant (up to 63 kA) and GM-SG-AR arc-resistant (up to 50 kA) :<br />

Main bus sizes 1,200 A, 2,000 A, 3,000 A or 4,000 A (self-cooled).<br />

No rollout auxiliaries allowed in upper cell (C or D) if lower cell (B) has 3,000 A circuit breaker. If 3,000 A circuit breaker is located in upper cell (A), one rollout auxiliary may be<br />

located in lower cell F.<br />

Auxiliary cells (C, D, E or F) may each contain one rollout (except as indicated in Footnotes 2 and 7).<br />

Fuse rollout for stationary CPT must be located in lower rollout cell F, if CPT is located in rear or is remote.<br />

Stacking arrangements are available as shown for all types of equipment in the GM-SG family. Total circuit breaker loading in a vertical unit may not exceed main bus rating.<br />

Consult Siemens for specific application assistance regarding total load limits in each unit or refer to ANSI/IEEE C37.20.2.<br />

Generator circuit breakers (type GMSG-GCB) conform to same stacking rules as standard (nongenerator) circuit breakers.<br />

For fan-cooled 4,000 A rating, circuit breaker (3,000 A self-cooled, 4,000 A fan-cooled) may be located in lower cell (B) with fan cooling in cell A.<br />

14-10<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Medium-voltage Equipment<br />

Types GM-SG and GM-SG-AR<br />

Stacking Versatility<br />

Stacking versatility continued<br />

GM-SG-AR arc-resistant 63 kA -<br />

1,200 A<br />

circuit<br />

breaker<br />

1,200 A<br />

circuit<br />

breaker<br />

Auxiliary<br />

1,200 A<br />

circuit<br />

breaker<br />

2,000 A<br />

circuit<br />

breaker<br />

2,000 A<br />

circuit<br />

breaker<br />

A<br />

A<br />

D<br />

A<br />

A<br />

A<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

1,200 A<br />

circuit<br />

breaker<br />

B<br />

Auxiliary<br />

B<br />

1,200 A<br />

circuit<br />

breaker<br />

B<br />

2,000 A<br />

circuit<br />

breaker<br />

B<br />

1,200 A<br />

circuit<br />

breaker<br />

B<br />

2,000 A<br />

circuit<br />

breaker<br />

B<br />

14 SWITCHGEAR<br />

Auxiliary<br />

2,000 A<br />

circuit<br />

breaker<br />

Vented 7<br />

Fan 7<br />

Auxiliary<br />

D<br />

A<br />

A<br />

A<br />

A<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

2,000 A<br />

circuit<br />

breaker<br />

Auxiliary<br />

3,000 A 7<br />

circuit<br />

breaker<br />

3,000 A 7<br />

circuit<br />

breaker<br />

Auxiliary<br />

B<br />

B<br />

B<br />

B<br />

B<br />

Footnotes for GM-SG-AR arc-resistant 63 kA:<br />

1. Main bus sizes 1,200 A, 2,000 A, 3,000 A or 4,000 A (self-cooled).<br />

No rollout auxiliaries allowed in upper cell (A) if lower cell (B) has 3,000 A circuit breaker.<br />

Auxiliary cells (A or B) may each contain one rollout (except as indicated in Footnotes 2 and 7).<br />

Fuse rollout for stationary CPT must be located in lower rollout cell B, if CPT is located in rear or is remote.<br />

Stacking arrangements are available as shown for arc-resistant type GM-SG-AR equipment rated 63 kA. Total circuit breaker loading in a vertical unit may not exceed main bus rating.<br />

Consult Siemens for specific application assistance regarding total load limits in each unit or refer to ANSI/IEEE C37.20.2.<br />

Generator circuit breakers (type GMSG-GCB) conform to same stacking rules as standard (nongenerator) circuit breakers.<br />

For fan-cooled 4,000 A rating, circuit breaker (3,000 A self-cooled, 4,000 A fan-cooled) may be located in lower cell (B) with fan cooling in cell A.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-11


Medium-voltage Equipment<br />

GM-SG Accessories<br />

General<br />

14<br />

SWITCHGEAR<br />

Accessories<br />

Standard accessories include:<br />

n Manual racking crank<br />

n Spring charging crank<br />

n Drawout extension rails (to enable<br />

handling of circuit breakers or<br />

auxiliary rollouts in upper cells or<br />

above floor level)<br />

n Lift sling (for circuit breakers or<br />

rollout trays above floor level)<br />

n Split plug jumper (standard unless<br />

test cabinet is furnished)<br />

n Contact lubricant<br />

n Touch-up paint<br />

n Auxiliary rollout tray insertion/<br />

withdrawal rods (arc-resistant up to<br />

50 kA)<br />

n Circuit breaker manual trip rod (arcresistant<br />

up to 63 kA).<br />

Optional accessories include:<br />

n Circuit breaker lift truck<br />

n Adapter for lift truck, for lifting<br />

auxiliary rollout trays for GM-SG (up<br />

to 63 kA) or GM-SG-AR (up to 50 kA)<br />

n Test cabinet (in place of split plug<br />

jumper)<br />

n Test plugs (if required by devices)<br />

n Portable electric racking motor<br />

assembly (to enable racking while<br />

operator is at a distance from the<br />

switchgear)<br />

n Manual or electrical ground and test<br />

device.<br />

Test provisions, either a split plug<br />

jumper or a test cabinet, are available<br />

for testing the circuit breaker outside<br />

its cubicle.<br />

Accessory cabinet<br />

Type GMSG circuit breaker on lift truck<br />

Drawout extension rails<br />

The split plug jumper is used to<br />

bridge the secondary disconnects<br />

with a flexible cable, so the circuit<br />

breaker may be electrically closed and<br />

tripped with the control switch on<br />

the instrument panel while the circuit<br />

breaker is outside of its compartment.<br />

The test cabinet, including a control<br />

switch, is used for closing and tripping<br />

the circuit breaker at a location remote<br />

from the switchgear.<br />

For arc-resistant equipment: rollout tray<br />

insertion/ withdrawal tools up to 50 kA<br />

and manual trip rod (up to 63 kA)<br />

14-12<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Medium-voltage Equipment<br />

GM-SG Accessories<br />

General<br />

Type GMSG-MO manually operated ground and test device<br />

Note: Due to the special nature of ground<br />

and test devices, each user must develop<br />

definitive operating procedures for incorporating<br />

safe operating practices. Only<br />

qualified personnel should be allowed to<br />

use ground and test devices.<br />

Manually operated ground and test<br />

device (up to 50 kA), type GMSG-MO<br />

The type GMSG-MO ground and test<br />

device (up to 50 kA) is a drawout<br />

element that can be inserted into a<br />

circuit breaker cell rated for a shortcircuit<br />

current of 50 kA or lower. The<br />

type GMSG-MO device opens the<br />

shutters, connects to the cell primary<br />

disconnecting contacts and provides a<br />

means to make the primary disconnect<br />

stabs available for testing or grounding.<br />

The type GMSG-MO device is suitable<br />

for high-potential testing of outgoing<br />

circuits of the switchgear main bus<br />

or for phase sequence checking. The<br />

type GMSGMO device also provides a<br />

means to connect temporary grounds<br />

to de-energized circuits for maintenance<br />

purposes.<br />

The manual ground and test<br />

incorporates three-position, single-pole<br />

switches (upper stabs to ground, neutral<br />

and lower stabs to ground), eliminating<br />

the need for userfurnished ground<br />

cables. The switches are hookstick<br />

operable and, in the closed position,<br />

are rated for the full momentary and<br />

short-time ratings of the associated<br />

switchgear. User-furnished grounding<br />

cables and commercially available<br />

ground clamps seldom have ratings<br />

equal to those of the switchgear.<br />

Type GMSG-EO electrically operated<br />

ground and test device<br />

Electrically operated ground and test<br />

device (for up to 50 kA and for 63 kA),<br />

type GMSG-EO<br />

An electrical ground and test device<br />

includes a power-operated switch<br />

(derived from a type GMSG circuit<br />

breaker) arranged to allow grounding<br />

one set of disconnect stabs. These<br />

devices are able to close and<br />

latch against short-circuit currents<br />

corresponding to the ratings of the<br />

equipment.<br />

The electrically operated ground and test<br />

device rated for a short-circuit current of<br />

50 kA can be used in any type GM-SG<br />

family circuit breaker compartment rated<br />

up to 50 kA.<br />

The 63 kA device can be used only<br />

in type GM-SG family circuit breaker<br />

compartments rated 63 kA.<br />

Neither the 50 kA device nor the 63 kA<br />

device require any adapters for use in<br />

cells.<br />

Two devices, one each for the upper<br />

and lower stabs, are required if<br />

grounding is desired to either side of<br />

the unit. The type GMSG-EO device<br />

also provides a means of access to the<br />

primary circuits for high potential tests<br />

or for phase sequence checking.<br />

14 SWITCHGEAR<br />

Separate insulated hinged panels cover<br />

the upper and lower stabs and include<br />

padlock provisions. The type GMSG-MO<br />

device also includes individual hookstickremovable<br />

barriers between each singlepole<br />

switch and the upper stabs and<br />

lower stabs.<br />

Due to the unique requirements<br />

frequently involved in such devices,<br />

all applications of electrically operated<br />

ground and test devices should be<br />

referred to Siemens for review.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-13


Medium-voltage Equipment<br />

Type GM-SG<br />

Dimensions<br />

Switchgear Side Views<br />

107.0 (2,718)<br />

118.7<br />

(3,015)<br />

to floor<br />

line<br />

3.6 (92)<br />

14<br />

95.3<br />

(2,419)<br />

Front of<br />

frame<br />

3.7 (94)<br />

Rear of<br />

frame<br />

110.3<br />

(2,802)<br />

to floor<br />

line<br />

SWITCHGEAR<br />

98.7 (2,507)<br />

Type GM-SG Indoor Switchgear<br />

Floor line<br />

Switchgear base 6.0 (152.4)<br />

101.9 (2,588)<br />

Type OGM-SG Non-Walk-In Outdoor Switchgear<br />

179.7 (4,564)<br />

Field assembly<br />

Factory assembly<br />

Front<br />

panel<br />

3.6 (92)<br />

44 (1,117) door<br />

41.6 (1,056) opening<br />

72 (1,929) aisle<br />

118.9<br />

(3,020)<br />

110.3<br />

(2,802) to<br />

floor line<br />

Floor line<br />

40.9<br />

(1,039)<br />

Switchgear base 6.0 (152.4)<br />

173.5 (4,407)<br />

Type SGM-SG Shelter-Clad Single-Aisle Outdoor Switchgear<br />

14-14<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Medium-voltage Equipment<br />

Type GM-SG-AR<br />

Dimensions<br />

Switchgear Side Views continued<br />

116.4<br />

(2,957)<br />

14 SWITCHGEAR<br />

102.8 (2,611)<br />

Type GM-SG-AR indoor switchgear<br />

179.7 (4,564)<br />

Factory assembly 70.6 (1,796)<br />

Factory assembly 109.1 (2,771)<br />

3.0 (76.2)<br />

2.0 (51.6)<br />

Exhaust<br />

plenum<br />

location<br />

127.2<br />

(3,231)<br />

115.0<br />

(2,921)<br />

44 (1,117) door<br />

41.6 (1,056)<br />

opening<br />

72 (1,929) aisle<br />

2.0 (51.6)<br />

105.7<br />

(2,685)<br />

135.6<br />

(2,802)<br />

40.8<br />

(1,036)<br />

Floor line<br />

Aisle floor<br />

6.0 (152.4)<br />

Switchgear base<br />

174.8 (4,440)<br />

Type SGM-SG-AR Shelter-Clad single-aisle outdoor switchgear<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-15


Medium-voltage Equipment<br />

38 kV Type GM38 Metal-Clad Switchgear General/Specifications<br />

14<br />

SWITCHGEAR<br />

Drawout Indoor Switchgear<br />

n Horizontal drawout type 38-3AH3<br />

vacuum circuit breaker<br />

n Uses the latest developments in<br />

vacuum interrupter technology<br />

n Highly reliable vacuum interrupters –<br />

MTTF over 57,000 years<br />

n Up to 50 full-fault interruptions<br />

n Meets or exceeds the latest ANSI,<br />

IEEE and NEMA standards<br />

n UL Listing available for 40 kA rating<br />

n Universal spare circuit breaker<br />

n Interlock permits insertion of higher<br />

rating vacuum circuit breaker into<br />

lower rated cell but not vice-versa<br />

n Front accessible circuit breaker<br />

operating mechanism for ease of<br />

maintenance<br />

n Closed door racking<br />

n Floor rollout circuit breaker in lower<br />

cell without a dolly<br />

n Visible secondary disconnect<br />

n One-high construction<br />

n Pair with Siemens protective relays to<br />

match any typical application<br />

n Available with SIERS - Siemens<br />

Integrated Electric-Racking System<br />

Type 38-3AH3 Circuit Breaker Ratings<br />

Circuit Breaker Type<br />

Measured Parameter<br />

38-3AH3-<br />

1500 38-3AH3-<br />

31 38-3AH3-<br />

40 <br />

Nominal Voltage Class kV 38.0 38.0 38.0<br />

General Nominal Three-Phase MVA Class MVA 1,500 — —<br />

Rated<br />

Maximum Design Voltage (V) kV rms 38.0 38.0 38.0<br />

Voltage Voltage Range Factor (K) K 1.65 1.0 1.0<br />

Insulation Withstand<br />

Power Frequency kV rms 80 80 80<br />

Levels<br />

Voltage Levels<br />

Lightning Impulse (BIL) kV peak 150 150 150<br />

Rated<br />

Values<br />

Related<br />

Required<br />

Capabilities<br />

Rated<br />

Current<br />

Current<br />

Closing and<br />

Latching<br />

(Momentary)<br />

Continuous <br />

Amperes<br />

1,200<br />

2,000<br />

3,000FC<br />

1,200<br />

2,000<br />

3,000FC<br />

1,200<br />

2,000<br />

3,000FC<br />

Short-Circuit (At Rated Maximum Design Voltage) (I) kA rms sym 21 31.5 40<br />

Interrupting Time Cycles/ms 5/83 5/83 5/83<br />

Permissible Tripping Delay (Y) Sec. 2 2 2<br />

Maximum Design Voltage (V) divided by K = (V/K) kA rms 23 38 38<br />

Maximum symmetrical (sym) interrupting (K x I) kA rms sym 35 31.5 40<br />

Short-Time Current (K x I) (three seconds) kA rms sym 35 31.5 40<br />

Asymmetrical kA rms 56 50 62<br />

Peak kA peak 95 85 104<br />

Type 38-3AH3-1500 ratings are in accord with ANSI C37.06-1987. Types 38-3AH3-31 and 38-3AH3-40 ratings conform to ANSI/IEEE C37.06-2009 ratings.<br />

Maximum voltage for which the circuit breaker is designed and the upper limit for operation.<br />

K is the ratio of rated maximum voltage to the lower limit of the range of operating voltage in which the required symmetrical and asymmetrical interrupting<br />

capabilities vary in inverse proportion to the operating voltage.<br />

3,000 A ratings are achieved using forced air cooling in the switchgear cubicle.<br />

To obtain the required symmetrical interrupting capability of a circuit breaker at an operating voltage between 1/K times rated maximum voltage and<br />

rated maximum voltage, the following formula shall be used.<br />

Rated Maximum Voltage<br />

Required Symmetrical Interrupting Capacity = Rated Short Circuit Current ×<br />

Operating Voltage<br />

For operating voltages below 1/K times rated maximum voltage, the required symmetrical interrupting capability of the circuit breaker shall be equal to<br />

K times rated short circuit current.<br />

With the limitations stated in 5.10 of ANSI/IEEE Standard C37.04-1979, all values apply for polyphase and line-to-line faults. For single phase-to-ground<br />

faults, the specific conditions stated in 5.10.2.3 of ANSI Standard C37.04-1979 apply.<br />

Current values in this row are not to be exceeded even for voltages below 1/K times rated maximum voltage. For voltages between rated maximum<br />

voltage and 1/K times rated maximum voltage, follow 5 above.<br />

Current values in this row are independent of operating voltage up to and including rated maximum voltage.<br />

Included for reference only—not listed in ANSI/IEEE C37.06.<br />

14-16<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Medium-voltage Equipment<br />

38 kV Type GM38 Metal-Clad Switchgear Dimensions<br />

Enclosure Dimensions<br />

Cubicle Dimensions—Per Vertical Section<br />

Type<br />

Indoor<br />

Shelter-Clad<br />

Single-Aisle<br />

Shelter-Clad<br />

Common- Aisle<br />

Aisle-less<br />

non-walk-in<br />

GM38<br />

SGM38<br />

SGM38<br />

OGM38<br />

Weight<br />

in lbs. (kg)<br />

5,000<br />

(2,273)<br />

6,400<br />

(2,909)<br />

11,700<br />

(5,318)<br />

5,800<br />

(2,636)<br />

Dimensions in inches (mm)<br />

Height Width Depth Drawout Aisle<br />

110.0<br />

(2,794)<br />

132.5<br />

(3,366)<br />

132.5<br />

(3,366)<br />

130.5<br />

(3,315)<br />

48.0<br />

(1,219)<br />

48.0<br />

(1,219)<br />

48.0<br />

(1,219)<br />

48.0<br />

(1,219)<br />

130.0<br />

(3,302)<br />

234.5<br />

(5,956)<br />

363.75<br />

(9,239)<br />

139.35<br />

(3,539)<br />

96.0 (2,438)<br />

Recommended<br />

96.0 (2,438)<br />

Included<br />

96.0 (2,438)<br />

Included<br />

96.0 (2,438)<br />

Recommended<br />

Type 38-3AH3 Circuit Breaker<br />

Weights in lbs. (kg)<br />

Cont.<br />

Current<br />

Amps<br />

Circuit BreakerType<br />

38-3AH3-1500 38-3AH3-31 38-3AH3-40<br />

1,200 800 (364) 800 (364) 850 (387)<br />

2,000 900 (409) 900 (409) 950 (432)<br />

3,000 1,000 (455) 1,000 (455) 1,050 (478)<br />

Add 6" (152 mm) to each end of lineup<br />

for aisle extension, 12" (305 mm) total.<br />

Add for roof overhang Non-Walk-in Shelter-Clad<br />

Rear (Cable Side) 3.875" (98 mm) 3.875" (98 mm)<br />

Front 6.875" (175 mm) 1.5" (38 mm)<br />

110.0<br />

(2,794)<br />

130.0<br />

(3,302)<br />

6.78<br />

(172)<br />

130.5<br />

(3,315)<br />

139.35<br />

(3,539)<br />

126.87<br />

(3,223)<br />

14 SWITCHGEAR<br />

Type GM38 indoor switchgear<br />

127.0<br />

(3,226)<br />

Type OGM38 non-walk-in outdoor switchgear<br />

8.0<br />

(203)<br />

234.5 (5,956)<br />

1.55<br />

(39)<br />

Field assembly<br />

139.35 (3,539)<br />

Factory assembled<br />

3.87<br />

(98)<br />

96.0<br />

(2,438)<br />

132.5<br />

(3,366)<br />

Aisle<br />

Front panel<br />

126.87<br />

(3,223)<br />

Floor line<br />

Aisle floor<br />

Switchgear base<br />

8.0<br />

(203)<br />

229.0 (5,817)<br />

Type SGM38 Shelter-Clad single-aisle outdoor switchgear<br />

3.87<br />

(98)<br />

Factory assembly<br />

363.75 (9,239)<br />

Field assembly<br />

Factory assembly<br />

3.87<br />

(98)<br />

96.0<br />

(2,438)<br />

126.87 (3,223)<br />

132.5 (3366)<br />

Front panel<br />

Aisle<br />

Front panel<br />

8.0<br />

(203)<br />

Floor line<br />

356.0 (9,042)<br />

Type SGM38 Shelter-Clad common-aisle outdoor switchgear<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-17


Medium-voltage Equipment<br />

38 kV GM38 Metal-Clad Switchgear Dimensions<br />

Side Views — 1,200 A, 2,000 A, 3,000 A Circuit Breakers/Auxiliary<br />

A<br />

110<br />

(2.794)<br />

14<br />

SWITCHGEAR<br />

A. Surge arrester<br />

Auxiliary/1,200A, 2,000 A or 3,000 A circuit breaker (no drawout<br />

auxiliaries in upper cell for 3,000 A fan-cooled circuit breaker)<br />

Circuit breaker 1,200 A or 2,000 A with VT auxiliary (downfeed<br />

cables)<br />

B<br />

C<br />

D<br />

B. Drawout<br />

primary<br />

current limiting<br />

fuses for VTs<br />

C. VTs<br />

E<br />

D. Drawout<br />

primary<br />

current<br />

limiting fuses<br />

for CPT<br />

E. Control power<br />

(1Ø or 3Ø)<br />

VT auxiliary/1,200 A or 2,000 A circuit breaker (upfeed cables)<br />

CPT fuse truck/stationary CPT (1Ø or 3Ø)<br />

130 (3,302) 30 (762)<br />

H<br />

F<br />

G<br />

F. Main bus to<br />

left side<br />

G. Main bus to<br />

right side<br />

H. Bus tie circuit<br />

breaker<br />

J<br />

K<br />

L<br />

M<br />

J. Feeder circuit<br />

breaker<br />

K. Main bus to<br />

right side<br />

L. Transition bus<br />

M. Main bus to<br />

left side (bus<br />

tie circuit<br />

breaker<br />

section)<br />

Auxiliary/Bus tie circuit breaker<br />

Auxiliary/feeder circuit breaker (adjacent to right side of bus tie<br />

circuit breaker section)<br />

14-18<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Medium-voltage Equipment<br />

38 kV Gas-Insulated Metal-Clad Switchgear General/Specifications<br />

Gas-Insulated Switchgear<br />

Types 8DA10 and 8DB10 mediumvoltage,<br />

gas-insulated switchgear are gasinsulated,<br />

vacuum circuit breaker designs<br />

with a voltage range of 4.16 kV to 38 kV.<br />

Lightning impulse withstand voltage<br />

ratings up to 200 kV BIL and interrupting<br />

ratings up to 40 kA are available.<br />

The types 8DA10 and 8DB10 mediumvoltage,<br />

gas-insulated switchgear designs<br />

feature fixed-mounted, vacuum circuit<br />

breakers, connectable to the main bus<br />

through three-position (closed-open-ready<br />

to ground) switches. The position of the<br />

switches is externally observable from<br />

the front of the unit using a convenient<br />

camera system. Medium-voltage, gasinsulated<br />

switchgear is suitable for<br />

systems where small size, arc resistance,<br />

environmental immunity or reduced<br />

maintenance needs are important.<br />

Depending upon the voltage rating,<br />

medium-voltage, gas-insulated switchgear<br />

is approximately 1/5th the size of<br />

conventional air-insulated switchgear.<br />

Features include:<br />

n Tested for arc-resistance to IEEE<br />

C37.20.7-2007, type 2A<br />

n Significantly reduced PPE needs<br />

n Compact – up to 80% smaller<br />

than air-insulated switchgear<br />

n 20-year internal maintenance<br />

cycle<br />

n Meets IEEE and IEC standards<br />

n UL or C-UL Listing available<br />

n Single-phase design eliminates<br />

phase-to-phase faults<br />

n Meets NEC visible disconnect<br />

requirement<br />

n Well suited for contaminated<br />

environments<br />

n Pair with Siemens protective<br />

relays to match any application.<br />

14 SWITCHGEAR<br />

Rated Values<br />

Maximum Design Voltage kV 15 27 38 42*<br />

Frequency Hz 60 60 60 60<br />

Power-Frequency Withstand Voltage (1 min.) kV rms 36 60 80 80<br />

Lightning Impulse Withstand Voltage kV peak 95 125 170; 200* 185; 200*<br />

Short-Circuit Interrupting Current kA 40 40 40 40<br />

Short-Time Withstand Current, 3 s kA 40 40 40 40<br />

Short-Circuit Making Current (close and latch) kA peak 104 104 104 104<br />

Peak Withstand Current kA peak 104 104 104 104<br />

Continuous Current of Main Bus A 4,000 4,000 4,000 4,000<br />

Continuous Current of Circuit Breakers A 2,500 2,500 2,500 2,500<br />

* On request. Consult factory<br />

Type 8DA dimensions in inches (mm)<br />

Type 8DB dimensions in inches (mm)<br />

73<br />

(1,850)<br />

47.2<br />

(1,200)<br />

82.7<br />

(2,100)<br />

47.2<br />

(1,200)<br />

106.3<br />

(2,700)<br />

106.3<br />

(2,700)<br />

59<br />

(1,500)<br />

59<br />

(1,500)<br />

23.6<br />

(600)<br />

64<br />

(1,625)<br />

23.6<br />

(600)<br />

105<br />

(2,665)<br />

Front view<br />

Side view<br />

Front view<br />

Side view<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-19


Medium-voltage Equipment<br />

OEM Component Offering<br />

Siemens Medium-voltage (MV) OEM Component Offering<br />

Qualified MV OEM Panel Builders<br />

can utilize Siemens’ skeleton or cell<br />

kit components to build out entire<br />

switchgear solutions. A full line up of<br />

Non-Arc GM-SG, GM38 ANSI and also<br />

select IEC components from Siemens’<br />

global portfolio are available:<br />

14<br />

SWITCHGEAR<br />

n MV Vacuum Circuit Breakers 5-38kV<br />

n Skeleton<br />

n Cell Kit<br />

n MOC and TOC<br />

n Ground and Test Devices<br />

n Rollouts<br />

n Bus Boots / Insulation Products<br />

n Lifting devices and other accessories<br />

For more information, please contact<br />

1-800-241-4453, email: info.us@<br />

siemens.com, or your local sales office.<br />

GMSG Skeleton<br />

SION 3AE5 IEC MV Breaker<br />

GMSG Cell kit<br />

GMSG Breaker<br />

14-20<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Medium-voltage Equipment<br />

5 – 15 kV SIEBREAK Metal-Enclosed Load Interrupter Switchgear General/Specifications<br />

SIEBREAK Metal-Enclosed Load Interrupter Switchgear<br />

Standard<br />

n Single, duplex, and selector switch<br />

types<br />

n Non-fused or fused<br />

n Indoor type 1 enclosure<br />

n Large 8” x 18” (203 mm x 457 mm)<br />

viewing window<br />

n Hinged, grounded metal barrier in<br />

front of switch blades<br />

n 11-gauge doors, covers, and barriers<br />

n Silver-plated copper bus<br />

n Provisions for key interlocking<br />

n Mechanical door and switch interlock<br />

n Upper and lower ventilation louvers<br />

n Glass-polyester bus supports<br />

n Non-corrosive nameplate<br />

n Space heater with thermostat<br />

n NEMA CC1 hole patterns for cable<br />

termination.<br />

n Meets or exceeds applicable<br />

standards from ANSI, IEEE, CSA,<br />

EEMAC, and NEMA.<br />

Optional<br />

n UL or C-UL Listing<br />

n Current-limiting or explusion fuses<br />

n Indoor type 2 drip-proof enclosure<br />

n Indoor type 12 dust-resistant<br />

enclosure<br />

n Outdoor non-walk-in type 3R<br />

enclosure<br />

n Motor-operated mechanism<br />

n Tin-plated copper bus.<br />

n Auxiliary switches (2 NO-2 NC)<br />

n Mimic bus<br />

n Ground studs<br />

n Screens and filters (indoor)<br />

Modular configurations to mount:<br />

n Surge arresters<br />

n Instrument transformers<br />

n Control power transformers<br />

n Power meters<br />

n Other auxiliary equipment.<br />

Applications:<br />

n Standalone bay<br />

n Transformer primary<br />

n Lineups.<br />

14 SWITCHGEAR<br />

SIEBREAK Specifications<br />

Rated voltage Type 5 kV 15 kV<br />

Rated frequency<br />

50/60 Hz<br />

Rated duration power frequency withstand voltage 19 kV 36 kV<br />

Rated lightning impulse withstand voltage (BIL) 60 kV 95 kV<br />

Fuse short circuit current rating Current Limiting 50 kA 50 kA<br />

Expulsion 37.5 29.4<br />

Switch rating Continuous Current 600 A and 1200 A<br />

Interrupting rms<br />

25 kA and 38 kA<br />

Momentary rms<br />

40 kA, 61 kA, 80 kA<br />

Assembly rating Main bus continuous current 1200 A and 2000 A<br />

Short-time 2 second<br />

25kA and 38 kA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-21


Medium-voltage Equipment<br />

SIMOVAC non-arc-resistant and SIMOVAC-AR arc-resistant MVC up to 7.2 kV<br />

General<br />

SIMOVAC Medium-voltage Controllers<br />

14<br />

SWITCHGEAR<br />

Siemens experience gained in over<br />

50 years of supplying mediumvoltage<br />

controllers in the U.S. has<br />

been captured in the SIMOVAC and<br />

SIMOVAC-AR designs. The objective<br />

has been to incorporate features<br />

designed to provide safety, while<br />

simplifying operation and maintenance,<br />

and reducing installation cost. Siemens<br />

is committed to providing products that<br />

are reliable and high quality. Typical<br />

applications include:<br />

n Squirrel-Cage Induction Motors (nonreversing,<br />

reversing or multi-speed)<br />

n Reduced-Voltage Starters (solid-state<br />

type)<br />

n Synchronous motors (brush-less type)<br />

n Transformer Feeders<br />

n Capacitor Bank Feeders<br />

n Power Bus Feeders (Tie).<br />

The utilization voltage range for the<br />

controllers is 2.3 kV through 7.2 kV.<br />

The Siemens SIMOVAC-AR and<br />

SIMOVAC medium-voltage controller<br />

allows the user to combine vacuum<br />

contactors, latched contactors and loadbreak<br />

switches in one lineup. The user<br />

can also connect directly to Siemens<br />

type GM-SG-AR or GM-SG mediumvoltage<br />

switchgear with a transition<br />

section. This provides extreme flexibility<br />

in systems design.<br />

Load-Break Switches (LBS)<br />

Drawout Controllers:<br />

n Full-Voltage Non-Reversing (FVNR)<br />

n Reduced-Voltage Solid State (SSRVS)<br />

n Brushless Synchronous (BL-SYNCH)<br />

n Two-Speed Two-Winding (2S2W)<br />

n Two-Speed One-Winding (2S1W)<br />

n Full-voltage reversing (FVR).<br />

E2 (Fused) Contactors — To meet<br />

interrupting capability required for NEMA<br />

Class E2 controllers, types 12SVC400<br />

and 12SVC800 contactors are provided<br />

with primary current-limiting fuses in<br />

each phase. The resulting interrupting<br />

ratings are shown in bottom table.<br />

Controller maximum current capability<br />

Type 1 non-arc-resistant;<br />

type 2 non-arc-resistant;<br />

Type 1 Type 12 nonarc-resistant<br />

Controller type<br />

type 3 outdoor non-arc-resistant arc-resistant<br />

Two-high compartment 340 A top 340 A top 340 A top<br />

with 12SVC400 controller 400 A bottom 400 A bottom 380 A bottom<br />

One-high compartment<br />

with 12SVC400 controller<br />

One-high compartment<br />

with 12SVC800 controller<br />

Controller assembly ratings<br />

Maximum<br />

voltage kV<br />

Short-circuit<br />

current class<br />

E2 kA<br />

5.0 63 60<br />

7.65 63 60<br />

400 A top or bottom<br />

Insulation<br />

level Main bus<br />

(impulse) continuous<br />

kV current A<br />

Typical<br />

SIMOVAC<br />

non-arcresistant<br />

controller<br />

Typical<br />

SIMOVAC-<br />

AR arcresistant<br />

controller<br />

400 A top<br />

or bottom<br />

Short-time current<br />

duration (main bus)<br />

1,200, 2,000, 10 cycles<br />

3,000, 4,000 (2-seconds optional)<br />

1,200, 2,000, 10 cycles<br />

3,000, 4,000 (2-seconds optional)<br />

380 A top<br />

or bottom<br />

720 A 720 A 630 A<br />

Internal arc resistance<br />

(SIMOVAC-AR only)<br />

Accessibility<br />

type 2B 0.5 seconds<br />

Accessibility<br />

type 2B 0.5 seconds<br />

Contactor/controller ratings<br />

All main bus ratings are on a self-cooled,<br />

ventilated basis.<br />

b Short-time duration for controllers without main bus is<br />

limited to contactor capability (with fuses).<br />

c Insulation level is for the controller, with inductive<br />

transformers disconnected for testing (per UL 347).<br />

d 50 kA with certain contactor/ fuse combinations.<br />

e Type 12 up to 2,000 A. Type 3R up to 3,000 A.<br />

Interrupting capacity Motor horsepower rating (three-phase) Transformer loads <br />

Enclosed<br />

System Vacuum continuous<br />

voltage contactor ampere rating Unfused class E1 Fused class E2 Synchronous motors Induction motors Max motor Max three- phase Max fuse<br />

kV Type A kA kA 0.8 PF 1.0 PF HP fuse rating kVA<br />

rating<br />

2.3 12SVC400 400 4.8 63 1,500 1,750 1,500 24R 1,500 450E <br />

2.3 12SVC800 720 7.2 63 3,000 3,500 3,000 57X 2,500 900E<br />

4.0 12SVC400 400 4.8 63 2,500 3,000 2,500 24R 2,500 450E <br />

4.0 12SVC800 720 7.2 63 5,500 6,000 5,500 57X 5,000 900E<br />

4.6 12SVC400 400 4.8 63 3,000 3,500 3,000 24R 3,000 450E<br />

4.6 12SVC800 720 7.2 63 6,000 7,000 6,000 57X 5,000 900E<br />

6.9 12SVC400 400 4.8 63 4,000 5,000 4,000 24R 2,000 -3,500 200E -18R<br />

6.9 12SVC800 720 7.2 63 8,000 10,000 8,000 57X 4,000-6,000 400E -57X <br />

Refer to Controller maximum current capability table<br />

for further detail.<br />

Based on self-cooled transformer rating.<br />

With 24R fuse, interrupting capacity is 50 kA.<br />

With 48X or 57X fuse, interrupting capacity is 50 kA.<br />

Maximum fuse is 18R.<br />

Fuse shown will not permit transformer forced cooling<br />

rating of 133 percent of self-cooled rating.<br />

14-22<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Medium-voltage Equipment<br />

SIMOVAC-AR medium-voltage controller<br />

General<br />

Arc-resistant, up to 720 A, and 2.4 kV, 4.16 kV and 6.9 kV<br />

Description<br />

A leader in the design of mediumvoltage<br />

controllers, Siemens offers its<br />

advanced arc-resistant medium-voltage<br />

controller with enhanced safety for<br />

your personnel. Siemens combined its<br />

knowledge as a leading manufacturer of<br />

motors worldwide and as a world-class<br />

supplier of medium-voltage controller<br />

innovation and technologies to deliver<br />

flexibility and reliability.<br />

Featuress and benefits<br />

n Tested for arc-resistance to IEEE<br />

C37.20.7-2007, up to 63 kA, 0.5 s,<br />

accessibility type 2B<br />

n UL 347 5th edition/CSA C22.2 No.<br />

253-09<br />

n 400 A bolt-in or plug-in (optional) or<br />

720 A bolt-in vacuum contactor<br />

n 400 A or 720 A non-load-break<br />

isolation switch<br />

n 2.4 kV, 4.16 kV and 6.9 kV (up to 7.65<br />

kV) system voltage ratings<br />

n 1,200 A, 2,000 A, 3,000 A or 4,000<br />

A main bus with standard epoxy<br />

insulation on bus bars, and with<br />

optional boots for insulating joints<br />

n Tin- or silver-plated bus available<br />

n Front accessible<br />

n Main bus and ground bus are<br />

supported and braced up to 63 kA<br />

two-second short-time capability<br />

n Top-mounted pressure relief channel<br />

shipped installed for reduced site<br />

installation time<br />

n Isolation switch with visible indication<br />

through viewing window to verify that<br />

the power cell is isolated from lineside<br />

source – no need to open panel<br />

door<br />

n Isolation switch mechanically<br />

interlocked with the access door<br />

to prevent user access to primary<br />

compartment when isolation switch is<br />

closed<br />

n Low-voltage compartment is<br />

isolated from the medium-voltage<br />

compartment<br />

n All components are front accessible,<br />

facilitating routine inspection or parts<br />

replacement<br />

n Current-limiting fuses, contactor<br />

assembly and isolating switch<br />

assembly are easily removed from<br />

the enclosure<br />

n The main bus compartment is top,<br />

side and front accessible for easy<br />

installation and extension.<br />

14 SWITCHGEAR<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-23


Medium-voltage Equipment<br />

SIMOVAC Controller Configurations<br />

Dimensions/Specification<br />

14<br />

SWITCHGEAR<br />

General description<br />

The Siemens SIMOVAC controller is<br />

an integrated system of contactors and<br />

components arranged for convenient<br />

access within a common enclosure<br />

consisting of one or more free-standing<br />

structural sections. SIMOVAC indoor<br />

sections are normally 36” (914 mm)<br />

wide, 30” (762 mm) deep and 95”<br />

(2,413 mm) tall, while SIMOVAC-AR<br />

indoor sections are normally 36” (914<br />

mm) wide, 40” (1,016 mm) deep and<br />

112” (2,845 mm) tall) as shown in the<br />

figures on the following page.<br />

1,200 A load-interrupter switch sections<br />

are similar but are usually 48” (1,218<br />

mm) wide.<br />

Outdoor controllers are similar except<br />

width increases 6” (152 mm) per<br />

section, height increases to 107.3”<br />

(2,725 mm), and depth increases to<br />

37.4” (950 mm).<br />

The controllers can be arranged to meet<br />

specific customer needs and can be<br />

configured to accept up to two starters<br />

per vertical section as shown in drawing<br />

in right column<br />

The modular compartments of the<br />

section may contain starters, lowvoltage/control<br />

devices or space for<br />

future starters.<br />

In general, each starter unit is divided<br />

into medium-voltage and low-voltage/<br />

control compartments each with<br />

its own door, and has the following<br />

features:<br />

n The low-voltage/control compartment<br />

is isolated from the medium-voltage<br />

compartment of the section with<br />

grounded metal barriers and provides<br />

ample space for relays, terminal<br />

blocks and other control circuit<br />

elements.<br />

n The medium-voltage compartment<br />

contains the vacuum contactor,<br />

primary fuses, current and voltage<br />

transformers (optional), a control<br />

power transformer (if applicable),<br />

a no-load isolating switch, load<br />

connections, and has space for<br />

optional surge protection devices<br />

such as surge limiters. (Refer to the<br />

figure below).<br />

G<br />

Item<br />

A<br />

B<br />

C<br />

D<br />

E<br />

F<br />

G<br />

H<br />

I<br />

D<br />

I<br />

I<br />

A<br />

C<br />

Description<br />

Main bus<br />

Vertical bus<br />

Bolt-in primary fuses<br />

12SVC400 contactor (plug-in shown)<br />

No-load isolating switch (shown closed)<br />

No-load isolating switch (shown open)<br />

Isolating switch operating handle<br />

Phase current transformers<br />

Load cables (internal) to user’s terminal<br />

pads on left side of compartment<br />

H<br />

H<br />

E<br />

F<br />

B<br />

Item<br />

Description<br />

A<br />

Isolating switch<br />

operating handle<br />

B<br />

C<br />

Primary current-limiting<br />

fuses<br />

Contactor<br />

G<br />

D<br />

E<br />

Phase current<br />

transformers<br />

Ground sensor<br />

transformer<br />

F<br />

H<br />

A<br />

F<br />

Primary fuses for control<br />

power transformer<br />

B<br />

B<br />

B<br />

G<br />

H<br />

I<br />

Control power<br />

transformer<br />

Outgoing cable<br />

terminations<br />

(with optional ball-type<br />

ground studs)<br />

Optional voltage<br />

transformers<br />

I<br />

D<br />

C<br />

A<br />

E<br />

D<br />

G<br />

C<br />

F<br />

12SVC400<br />

12SVC800<br />

14-24<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Medium-voltage Equipment<br />

SIMOVAC Controller Configurations<br />

Dimensions/Specification<br />

Typical SIMOVAC non-arc-resistant controller configurations <br />

A<br />

A<br />

A<br />

A<br />

A<br />

B<br />

B<br />

D<br />

F<br />

C<br />

E<br />

G<br />

F<br />

D<br />

C<br />

H<br />

F<br />

C<br />

D<br />

F<br />

D<br />

F<br />

B<br />

C<br />

E<br />

C<br />

E<br />

I<br />

J<br />

One-high<br />

controller<br />

36 (914) 1<br />

Load-interrupter<br />

switch - 600 A<br />

Incoming line<br />

Item Description Item Description Item Description<br />

A Main bus compartment E Isolating switch handle I Upper controller compartment<br />

B Isolating switch blade viewing window F High-voltage door J Lower controller compartment<br />

C High-voltage door handle G Interrupter switch blade viewing window<br />

D Low-voltage door H Interrupter switch handle<br />

36 (914) 30 (762)<br />

Two-high<br />

Side view<br />

controllers<br />

14 SWITCHGEAR<br />

Typical SIMOVAC-AR arc-resistant controller configurations<br />

K K K K K<br />

A<br />

A<br />

A<br />

A<br />

A<br />

B<br />

B<br />

D<br />

F<br />

C<br />

E<br />

G<br />

F<br />

D<br />

C<br />

H<br />

F<br />

C<br />

D<br />

F<br />

D<br />

F<br />

C<br />

E<br />

B<br />

C<br />

E<br />

I<br />

J<br />

One-high<br />

controller<br />

36 (914) 1<br />

Load-interrupter<br />

switch - 600 A<br />

Incoming line<br />

36 (914) 40 (1,016)<br />

Two-high<br />

Side view<br />

controllers<br />

Item Description Item Description Item Description<br />

A Main bus compartment E Isolating switch handle I Upper controller compartment<br />

B Isolating switch blade viewing window F High-voltage door J Lower controller compartment<br />

C High-voltage door handle G Interrupter switch blade viewing window K Pressure relief channel<br />

D Low-voltage door H Interrupter switch handle<br />

600 A load-interrupter switches are 36” (914 mm) wide.<br />

1,200 A switches are 48” (1,218 mm) wide.<br />

For outdoor non-arc-resistant configurations, add 6”<br />

(151 mm) per section.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-25


Medium-voltage Equipment<br />

Motor Protection<br />

Protective Relaying<br />

14<br />

SWITCHGEAR<br />

Overload protection –<br />

types 3RU or 3RB<br />

Running overcurrent (overload)<br />

protection for the motor must also<br />

be provided according to NEMA<br />

standards. This overload (or longtime)<br />

protection can be provided by the<br />

Siemens type 3RU (OLR) bimetallic<br />

thermal overload relay. This three-phase<br />

adjustable relay provides inherent<br />

singlephase protection and phase<br />

unbalance protection with NEMA class<br />

10 tripping characteristics, providing<br />

optimum protection for motors having<br />

acceleration times of six seconds or<br />

less and allowable hot locked rotor<br />

times of five seconds or more. It is<br />

equipped with an isolated normally<br />

open contact to actuate a remote alarm<br />

in the event of an overload trip.<br />

SIPROTEC protective relays<br />

The SIPROTEC protective relay family<br />

includes many of the secondary ANSI<br />

functions, allowing the user to use one<br />

protective relay for motor protection<br />

applications.<br />

Type SIPROTEC 5 relay<br />

SIMOVAC and SIMOVAC-AR can also<br />

be equipped with the SIPROTEC 5<br />

arc-protection solution that optically<br />

detects arcs reliably as they develop.<br />

The SIPROTEC 5 protective relay is<br />

then able to initiate a command to<br />

open an upstream circuit breaker to<br />

quickly clear the arcing fault, reducing<br />

potential damage to the equipment,<br />

and providing better protection for<br />

personnel.<br />

Type 3RU overload relay<br />

Type 3RB overload relay<br />

14-26<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Protective Relays & SCADA Systems<br />

SCADA Substation Automation<br />

General<br />

SICAM PAS & PQ Analyzer<br />

SICAM PAS (Power Automation System)<br />

is a complete substation automation<br />

control and protection system for HV<br />

and MV switchgear (i.e., >600 volts)<br />

used in electric utility and industrial<br />

facility substations. SICAM PAS offers<br />

many time and cost saving benefits for<br />

entities along the switchgear value chain<br />

including, electric utilities, industrial plant<br />

owners, switchgear manufacturers,<br />

designers, integrators, panel builders,<br />

installers and OEMs.<br />

Key Features<br />

n Integrated substation automation<br />

system for SCADA monitoring,<br />

control and system protection.<br />

n Fully compliant with the IEC 61850<br />

industry design standard.<br />

n Automated Power Quality and<br />

protection relay fault record retrieval<br />

and data reporting (supports NERC<br />

PRC-002 and 005).<br />

n Substation Human Machine Interface<br />

(HMI) for visualization, alarm handling<br />

and control using graphical displays.<br />

n NERC CIP cyber security compliance<br />

tools.<br />

n Redundant server option for greater<br />

reliability<br />

n Communications redundancy via<br />

Parallel Redundancy Protocol (PRP)<br />

and High Availability Redundancy<br />

Protocol (HSR)<br />

n Fully complient with IEC 61850<br />

Edition 2<br />

Benefits<br />

n SICAM PAS saves designers, panel<br />

builders and OEMs time and money<br />

to deploy standardized and reusable<br />

protection and control systems.<br />

n SICAM PAS is interoperable with<br />

third-party devices using IEC 61850,<br />

DNP, OPC and Modus communication<br />

protocols.<br />

n The IEC 61850 design standard<br />

results in a a 70% reduction of panel<br />

wiring which saves in material costs<br />

and installation and test time.<br />

n IEC 61850 also provides the<br />

means to bench test and debug<br />

the system and protection design<br />

before the switchgear is deployed<br />

in the substation, which significantly<br />

reduces the project schedule and<br />

on-site integration risk.<br />

n Plant owners can see savings through<br />

automated power quality reporting.<br />

SICAM PAS Substation Server<br />

SICAM PAS works on industrialstandard<br />

hardware with the Microsoft<br />

Windows operating systems. The<br />

advantages of this platform are low<br />

hardware and software costs, ease<br />

of operation, scalability, flexibility and<br />

constantly available support. With the<br />

powerful real-time data distribution<br />

system, applications can be allocated<br />

among several computers, thus<br />

boosting performance, connectivity<br />

and availability of over 600 intelligent<br />

electronic devices. A database system<br />

stores and organizes the data basis<br />

(e.g. configuration data, administrative<br />

status data, etc.). The device master<br />

function for communication with<br />

Intelligent Electronic Devices (IEDs)<br />

supports a large number of well<br />

established protocols. The SICAM<br />

PAS data normalization function allows<br />

conversions such as measured-value<br />

filtering, threshold value calculation and<br />

linear characteristics.<br />

SICAM PAS CC HMI<br />

SICAM PAS CC is used for process<br />

visualization. Specifically designed<br />

for energy applications, it assists the<br />

operating personnel in optimizing the<br />

operations management. It provides<br />

quick visualization and response to<br />

substation conditions. SICAM SCC is<br />

based on SIMATIC WinCC, one of the<br />

leading process visualization systems<br />

that is used in industrial automation<br />

world. The client-server architecture<br />

allows for up to 16 client off of a signal<br />

server for extensive visualization of<br />

the power system throughout the<br />

substation and industrial plant.<br />

14 SWITCHGEAR<br />

Siemens Siprotec Relay (see Siprotec<br />

specific info on page 14-28)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-27


Protective Relays & SCADA Systems<br />

SIPROTEC Protective Relays<br />

General<br />

SIPROTEC Relays: Premier protection with less engineering effort<br />

SWITCHGEAR<br />

14<br />

Engineering for relaying systems costs many times more than<br />

the purchase price of the relays themselves. The SIPROTEC<br />

line of relays from Siemens is designed and built to simplify<br />

design and configuration, while reducing ownership costs.<br />

The hardware and firmware design of SIPROTEC relays are<br />

proven to stand up to tough substation operating conditions<br />

worldwide. Separate design and validation steps provide<br />

stable operating systems to minimize in-service firmware<br />

upgrades.<br />

Stable firmware process<br />

SIPROTEC relays reduce total ownership cost and engineering<br />

effort for firmware upgrades – only one critical firmware<br />

upgrade has been required in the past 12 years.<br />

Unmatched reliability<br />

Siemens SIPROTEC protective relays average a 600-year<br />

mean time between failures (MTBF), meaning for every<br />

600 relays you own, you can expect one or fewer failures<br />

per year. This measurement is the result of over 1.2 million<br />

relays installed worldwide, and it includes “out-of-the-box” or<br />

“initial” failures.<br />

High reliability measured on more than one million digital<br />

relays in service.<br />

Important: SIPROTEC quality data does not exclude “out-ofthe-box”<br />

or “initial” failures.<br />

14-28<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Protective Relays & SCADA Systems<br />

SIPROTEC Protective Relays<br />

General<br />

Stable, easy and powerful software<br />

DIGSI setting software simplifies protection and automation<br />

configuration to reduce human performance errors. It also<br />

reduces total ownership costs with a historical track record of<br />

high-stability and low-upgrade frequency, saving on substation<br />

trips and upgrade times.<br />

DIGSI software provides intuitive setting and configuration for single<br />

or multiple relays<br />

Export to popular CAD systems reduces errors and cost.<br />

Powerful CFC logic enables flexible operating arrangements<br />

using digital and analog measurements. Pre-configured<br />

logic for single and dual-breaker or breaker-and-a-half bus<br />

configurations reduces needed settings for faster setup.<br />

SIGRA fault analysis software provides the most advanced<br />

tool for relay engineers to identify fault conditions. Users can<br />

view multiple events, calculate system impedances, relay<br />

values, and other elements to better understand relay and<br />

power system performance.<br />

SIGRA event analysis software provides viewing and calculations for<br />

Comtrade event files<br />

Easy to upgrade for future applications<br />

n Modular hardware for easy additions and field changes<br />

– Next time your requirements change, simply adjust your<br />

expansion modules for communications, I/O, displays,<br />

and fault recording memory.<br />

n Change functions to match changing conditions<br />

– Load only the functions needed into the relay<br />

– Add or remove protection elements with drop-and-drag<br />

functionality<br />

– Avoid setting and CPU clutter by eliminating unnecessary<br />

protection functions<br />

Pre-loaded resident protection elements can be activated,<br />

duplicated or de-activated at any time in the future, without<br />

changing firmware<br />

SIPROTEC 5<br />

DIGSI 5<br />

14 SWITCHGEAR<br />

49T 50N 27 87M 66 24<br />

32R<br />

õ<br />

40 59 64 51N<br />

67 87L 61G 79 63 50<br />

40 59 64 51N 49 64R<br />

81 21 67G 79<br />

81 21 67G 79 63 51V<br />

32R 87T 51 87N<br />

32R 87T 51 87N 37 ...<br />

This is like a protection “buffet service,” where the user self<br />

serves by dragging and dropping.<br />

For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-29


Protective Relays & SCADA Systems<br />

SIPROTEC Protective Relays<br />

Selection<br />

ANSI Selection List for Protective Relays<br />

Distance<br />

Pilot wire differential<br />

Line differential<br />

Overcurrent<br />

Motor protection<br />

Differential<br />

Generator and<br />

motor protection<br />

Breaker management<br />

Synchronizing<br />

14<br />

SWITCHGEAR<br />

7SA522<br />

7SA6<br />

7SD600<br />

7SD5<br />

7SD610<br />

7SJ45<br />

7SJ46<br />

7SJ600<br />

7SJ602<br />

7SJ80<br />

7SJ61<br />

7SJ62<br />

7SJ63<br />

7SJ64<br />

7SK80<br />

7VH60<br />

7UT612<br />

7UT613<br />

7UT63<br />

7SS60<br />

7SS52<br />

7UM61<br />

7UM62<br />

7VK61<br />

7VE6<br />

7SV600<br />

7RW600<br />

Breaker failure<br />

Voltage, frequency<br />

ANSI<br />

No.* Protection functions<br />

14 Locked rotor protection — — — — — — — — — — l l l l ■ — — — — — — ■ ■ — — — —<br />

21 Distance protection, phase ■ ■ — l — — — — — — — — — — — — — — — — — ■ ■ — — — —<br />

21N<br />

Distance protection, earth<br />

(ground)<br />

■ ■ — l — — — — — — — — — — — — — — — — — — — — — — —<br />

21FL Fault locator ■ ■ — l — — — — — l — l l l — — — — — — — — — — — — —<br />

24 Overfluxing (V/f protection) — — — — — — — — — — — — — — — — — l l — — ■ ■ — — — ■<br />

25<br />

Synchronizing, synchronism<br />

check<br />

l l — l — — — — — l — l — l — — — — — — — — — ■ ■ — —<br />

27 Undervoltage l l — l l — — — — l — l l l l — — — l — — ■ ■ l l — ■<br />

27/34 Stator earth-fault 3rd harmonic — — — — — — — — — — — — — — — — — — — — — ■ ■ — — — —<br />

32 Directional power — — — — — — — — — l — l — l l — — — l — — — ■ — — — —<br />

32F Forward power — — — — — — — — — l — l — l l — — l — — — l ■ — — — —<br />

32R Reverse power — — — — — — — — — l — l — l l — — l — — — ■ ■ — — — —<br />

37 Undercurrent or underpower — — — — — — — — l ■ ■ ■ ■ ■ ■ — — — — — — — ■ — — — —<br />

40 Loss of field — — — — — — — — — — — — — — — — — — — — — l ■ — — — —<br />

46<br />

Load unbalance, negative<br />

phase-sequence overcurrent<br />

— — — — — — — ■ ■ ■ ■ ■ ■ ■ ■ — l — l — — l l — — — —<br />

47 Phase-sequence voltage ■ ■ — ■ — — — — — l — ■ ■ ■ l — — — — — — ■ ■ — — — —<br />

48<br />

Incomplete sequence,<br />

locked rotor<br />

— — — — — — — ■ l — l l l l ■ — — — — — — l l — — — —<br />

49 Thermal overload — l — ■ ■ — — ■ ■ ■ ■ ■ ■ ■ ■ — ■ ■ ■ — — ■ ■ — — — —<br />

49R Rotor thermal protection — — — — — — — ■ ■ — ■ ■ ■ ■ ■ — — — — — — — ■ — — — —<br />

49S Stator thermal protection — — — — — — — ■ ■ — ■ ■ ■ ■ ■ — — — — — — ■ ■ — — — —<br />

50 Instantaneous overcurrent ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ — ■ ■ ■ — l ■ ■ ■ — — —<br />

50N<br />

Instantaneous earth-fault<br />

overcurrent<br />

■ ■ — ■ ■ — — ■ ■ ■ ■ ■ ■ ■ ■ — ■ ■ ■ — l ■ ■ — — — —<br />

50BF Breaker failure l l — ■ l — — — ■ ■ ■ ■ ■ ■ ■ — l l l — ■ ■ ■ ■ — ■ —<br />

51GN<br />

Zero speed and<br />

underspeed device<br />

— — — — — — — — — — — — — — — — — — — — — — ■ — — — —<br />

51 Overcurrent-time relay, phase ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ — ■ ■ ■ — l ■ ■ — — — —<br />

51N Overcurrent-time relay, earth ■ ■ — ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ — ■ ■ ■ — l ■ ■ — — — —<br />

51M Load jam protection — — — — — — — — — — l l l l ■ — — — — — — — — — — — —<br />

51V<br />

Overcurrent-time relay, voltage<br />

controlled<br />

— — — — — — — — — — — ■ — ■ — — — — — — — ■ ■ — — — —<br />

59 Overvoltage l l — l l — — — — l — l l l l — — — l — — ■ ■ l l — ■<br />

59N<br />

Residual voltage earth-fault<br />

protection<br />

l l — l — — — — ■ l — ■ ■ ■ l — — — — — — ■ ■ — — — —<br />

59GN Stator earth-fault protection — — — — — — — — — — — — — — — — — — — — — ■ ■ — — — —<br />

64<br />

100 % Stator earth-fault protection<br />

(20 Hz)<br />

— — — — — — — — — — — — — — — — — — — — — — l — — — —<br />

64R Rotor earth fault — — — — — — — — — — — — — — — — — — — — — ■ ■ — — — —<br />

n Standard function<br />

l Optional<br />

] ANSI/IEEE C37.2: IEEE Standard Electrical Power System Device Function Numbers<br />

For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office.<br />

14-30<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Protective Relays & SCADA Systems<br />

SIPROTEC Protective Relays<br />

Selection<br />

ANSI Selection List for Protective Relays<br />

Distance<br />

Pilot wire differential<br />

Line differential<br />

Overcurrent<br />

Motor protection<br />

Differential<br />

Generator and<br />

motor protection<br />

Breaker management<br />

Synchronizing<br />

Breaker failure<br />

7SA522<br />

7SA6<br />

7SD600<br />

7SD5<br />

7SD610<br />

7SJ45<br />

7SJ46<br />

7SJ600<br />

7SJ602<br />

7SJ80<br />

7SJ61<br />

7SJ62<br />

7SJ63<br />

7SJ64<br />

7SK80<br />

7VH60<br />

7UT612<br />

7UT613<br />

7UT63<br />

7SS60<br />

7SS52<br />

7UM61<br />

7UM62<br />

7VK61<br />

7VE6<br />

7SV600<br />

7RW600<br />

Voltage, frequency<br />

ANSI<br />

No.* Protection functions<br />

67 Directional overcurrent — — — — l — — — — l — l l l — — — — — — — ■ ■ — — — —<br />

67N<br />

Directional earth-fault<br />

overcurrent<br />

l l — l l — — — ■ l — l l l l — — — — — — ■ ■ — — — —<br />

67G<br />

Stator earth-fault directional<br />

overcurrent<br />

— — — — — — — — — — — — — — — — — — — — — ■ ■ — — — —<br />

68 Power swing detection l l — l — — — — — — — — — — — — — — — — — — l — — — —<br />

74TC Trip circuit supervision ■ ■ — ■ ■ — — ■ ■ ■ ■ ■ ■ ■ ■ — l l l — — ■ ■ ■ — — —<br />

78 Out-of-step protection — — — — — — — — — — — — — — — — — — — — — — ■ — — — —<br />

79 Auto-reclosure l l — l l — — l l l l l l l — — — — — — — — — ■ — — —<br />

81 Frequency protection ■ ■ — l l — — — — l — l l l l — — — l — — ■ ■ — l — ■<br />

81R<br />

Rate-of-frequency-change<br />

protection<br />

— — — — — — — — — l — l — — l — — — — — — l l — l — l<br />

Vector jump supervision — — — — — — — — — — — — — — — — — — — — — l l — l — —<br />

14 SWITCHGEAR<br />

85 Carrier interface/remote trip ■ ■ l ■ ■ — — — — — — — — — — — — — — — ■ — — — — — —<br />

86 Lockout function ■ ■ ■ ■ ■ — — — — ■ ■ ■ ■ ■ ■ — ■ ■ ■ ■ — ■ ■ ■ l — —<br />

87G<br />

Differential protection<br />

generator<br />

— — — — — — — — — — — — — — — — ■ ■ ■ — — — ■ — — — —<br />

87T<br />

Differential protection<br />

transformer<br />

— — ■ l l — — — — — — — — — — ■ ■ ■ ■ — — — ■ — — — —<br />

87BB Differential protection busbar — — — — — — — — — — — — — — — — ■ ■ ■ ■ ■ — — — — — —<br />

87M Differential protection motor — — — — — — — — — — — — — — — — ■ ■ ■ — — — ■ — — — —<br />

87L Differential protection line — — ■ ■ ■ — — — — — — — — — — — ■ ■ ■ — — — — — — — —<br />

87N<br />

Restricted earth-fault<br />

protection<br />

— — — l l — — — — ■ ■ ■ ■ ■ — ■ l l l — — — l — — — —<br />

n Standard function<br />

l Optional<br />

] ANSI/IEEE C37.2: IEEE Standard Electrical Power System Device Function Numbers<br />

Only sensitive directional earth-fault overcurrent (67Ns).<br />

For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-31


Protective Relays & SCADA Systems<br />

SIPROTEC Protective Relays<br />

Selection<br />

Siemens Protective Relays - Quick Competitor Comparison by Application<br />

Motor Protection<br />

Model Siemens Equivalent Typical Catalog Number<br />

GE 239 7SK80 7SK8051-5EC96-3HD0+L0G<br />

GE 269 7SK80 7SK8051-5EC96-3HD0+L0G<br />

GE 269+ 7SK80 7SK8051-5EC96-3HD0+L0G<br />

GE 369 7SK80 SIMPRO-100-R-V<br />

GE 469 7SK80 and 7SJ601 SIMPRO-100-R-V/7SJ6015-4EA01-0AA0<br />

Feeder Protection<br />

14<br />

SWITCHGEAR<br />

Model Siemens Equivalent Typical Catalog Number<br />

ABB CO (4 single phase) 7SJ45 (1 three phase) 7SJ4505-1EA00-1AA1 (1 three phase)<br />

7SJ46 (1 three phase)<br />

7SJ4605-1EA00-1AA0 (1 three phase)<br />

7SJ601 (1 three phase)<br />

7SJ6015-4EA01-0AA0 (1 three phase)<br />

ABB Microshield 7SJ600 7SJ6005-4EA00-0DA1<br />

7SJ602<br />

7SJ6025-4EB00-1FA0<br />

7SJ80<br />

7SJ8041-5EC96-3FC1+L0G<br />

7SJ61<br />

7SJ6115-5EC90-1FA0+L0D<br />

7SJ62<br />

7SJ6215-5EC90-1FE0+L0D<br />

ABB DPU-1500 7SJ62 7SJ6215-5EC90-1FE0+L0D<br />

7SJ63<br />

7SJ6315-5EC90-1FE0+L0D<br />

7SJ64<br />

7SJ6405-5EC92-1FE4+L0D<br />

ABB DPU-2000R 7SJ62 7SJ6215-5EC90-1FE0+L0D<br />

7SJ63<br />

7SJ6315-5EC90-1FE0+L0D<br />

7SJ64<br />

7SJ6405-5EC92-1FE4+L0D<br />

Basler BE3-51 (4 single phase) 7SJ45 (1 three phase) 7SJ4505-1EA00-1AA1 (1 three phase)<br />

7SJ46 (1 three phase)<br />

7SJ4605-1EA00-1AA0 (1 three phase)<br />

Basler BE1-51 (4 single phase) 7SJ45 (1 three phase) 7SJ4505-1EA00-1AA1 (1 three phase)<br />

7SJ46 (1 three phase)<br />

7SJ4605-1EA00-1AA0 (1 three phase)<br />

7SJ601 (1 three phase)<br />

7SJ6015-4EA01-0AA0 (1 three phase)<br />

Basler BE1-851 7SJ600 7SJ6005-4EA00-0DA1<br />

7SJ602<br />

7SJ6025-4EB00-1FA0<br />

7SJ80<br />

7SJ8041-5EC96-3FC1+L0G<br />

7SJ61<br />

7SJ6115-5EC90-1FA0+L0D<br />

Basler BE1-951 7SJ62 7SJ6215-5EC90-1FE0+L0D<br />

7SJ63<br />

7SJ6315-5EC90-1FE0+L0D<br />

7SJ64<br />

7SJ6405-5EC92-1FE4+L0D<br />

GE MDP 7SJ45 7SJ4505-1EA00-1AA1<br />

7SJ46<br />

7SJ4605-1EA00-1AA0<br />

7SJ601<br />

7SJ6015-4EA01-0AA0<br />

7SJ80<br />

7SJ8041-5EC96-3FC1+L0G<br />

GE 735 7SJ600 7SJ6005-4EA00-0DA1<br />

7SJ602<br />

7SJ6025-4EB00-1FA0<br />

7SJ80<br />

7SJ8041-5EC96-3FC1+L0G<br />

7SJ61<br />

7SJ6115-5EC90-1FA0+L0D<br />

GE 750 7SJ62 7SJ6215-5EC90-1FE0+L0D<br />

7SJ63<br />

7SJ6315-5EC90-1FE0+L0D<br />

7SJ64<br />

7SJ6405-5EC92-1FE4+L0D<br />

GE F60 7SJ62 7SJ6215-5EC90-1FE0+L0D<br />

7SJ63<br />

7SJ6315-5EC90-1FE0+L0D<br />

7SJ64<br />

7SJ6405-5EC92-1FE4+L0D<br />

SEL 351A 7SJ62 7SJ6215-5EC90-1FE0+L0D<br />

7SJ63<br />

7SJ6315-5EC90-1FE0+L0D<br />

7SJ64<br />

7SJ6405-5EC92-1FE4+L0D<br />

SEL 351 7SJ62 7SJ6215-5EC90-1FE0+L0D<br />

7SJ63<br />

7SJ6315-5EC90-1FE0+L0D<br />

7SJ64<br />

7SJ6405-5EC92-1FE4+L0D<br />

SEL 351S 7SJ62 7SJ6215-5EC90-1FE0+L0D<br />

7SJ63<br />

7SJ6315-5EC90-1FE0+L0D<br />

7SJ64<br />

7SJ6405-5EC92-1FE4+L0D<br />

SEL 501 7SJ600 7SJ6005-4EA00-0DA1<br />

7SJ602<br />

7SJ6025-4EB00-1FA0<br />

7SJ80<br />

7SJ8041-5EC96-3FC1+L0G<br />

7SJ61<br />

7SJ6115-5EC90-1FA0+L0D<br />

SEL 551 7SJ600 7SJ6005-4EA00-0DA1<br />

7SJ602<br />

7SJ6025-4EB00-1FA0<br />

7SJ80<br />

7SJ8041-5EC96-3FC1+L0G<br />

7SJ61<br />

7SJ6115-5EC90-1FA0+L0D<br />

*Siemens catalog numbers in Bold are the preferred equivalent model.<br />

Siemens does not accept any liability for the information contained in this document.<br />

For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office.<br />

14-32<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Protective Relays & SCADA Systems<br />

SIPROTEC Protective Relays<br />

Selection<br />

General Protection<br />

Model Siemens Equivalent Typical Catalog Number<br />

ABB GPU2000 7UM62 7UM6215-5EC90-0BA0+L0D<br />

Basler BE1- GPS100 7UM61 7UM6115-5EC90-0CA0+L0D<br />

7UM62<br />

7UM6215-5EC90-0BA0+L0D<br />

Beckwith M-3420 7UM61 7UM6115-5EC90-0CA0+L0D<br />

7UM62<br />

7UM6215-5EC90-0BA0+L0D<br />

Beckwith M-3425 7UM62 7UM6215-5EC90-0CA0+L0D<br />

GE 489 7UM61 7UM6115-5EC90-0CA0+L0D<br />

7UM62<br />

7UM6215-5EC90-0BA0+L0D<br />

SEL 300G 7UM61 7UM6115-5EC90-0CA0+L0D<br />

7UM62<br />

7UM6215-5EC90-0BA0+L0D<br />

Bus Protection<br />

Model Siemens Equivalent Typical Catalog Number<br />

ABB HU 7VH60 7VH6002-0EA20-0AA0<br />

ABB CA 7VH60 7VH6002-0EA20-0AA0<br />

ABB TPU2000R 7UT513 7UT5135-4GB11-1AA0<br />

7UT612<br />

7UT6125-5EC00-1AA0<br />

Basler BE1-87 7UT513 7UT5135-4GB11-1AA0<br />

7UT612<br />

7UT6125-5EC00-1AA0<br />

(3) 7VH60 7VH6002-0EA20-0AA0<br />

GE PVD 7VH60 7VH6002-0EA20-0AA0<br />

GE B30 7UT513 7UT5135-4GB11-1AA0<br />

7UT612<br />

7UT6125-5EC00-1AA0<br />

SEL 387 7UT513 7UT5135-4GB11-1AA0<br />

7UT612<br />

7UT6125-5EC00-1AA0<br />

Transformer Protection<br />

14 SWITCHGEAR<br />

Model Siemens Equivalent Typical Catalog Number<br />

ABB HU (3) 7UT512 (1) 7UT5125-4GB11-0AA0<br />

7UT513 (1)<br />

7UT5135-4GB11-1AA0<br />

7UT612 (1)<br />

7UT6125-5EC00-1AA0<br />

ABB CA (3) 7UT512 (1) 7UT5125-4GB11-0AA0<br />

7UT513 (1)<br />

7UT5135-4GB11-1AA0<br />

7UT612 (1)<br />

7UT6125-5EC00-1AA0<br />

ABB TPU2000R 7UT512 7UT5125-4GB11-0AA0<br />

7UT513<br />

7UT5135-4GB11-1AA0<br />

7UT612<br />

7UT6125-5EC00-1AA0<br />

Basler BE1-CDS 7UT513 7UT5135-4GB11-1AA0<br />

7UT612<br />

7UT6125-5EC00-1AA0<br />

GE 745 7UT513 7UT5135-4GB11-1AA0<br />

7UT612<br />

7UT6125-5EC00-1AA0<br />

GE T60 7UT513 7UT5135-4GB11-1AA0<br />

7UT612<br />

7UT6125-5EC00-1AA0<br />

SEL 387 7UT513 7UT5135-4GB11-1AA0<br />

7UT612<br />

7UT6125-5EC00-1AA0<br />

SEL 587 7UT512 7UT5125-4GB11-0AA0<br />

7UT513<br />

7UT5135-4GB11-1AA0<br />

7UT612<br />

7UT6125-5EC00-1AA0<br />

Voltage/Frequency Protection<br />

Model Siemens Equivalent Typical Catalog Number<br />

Basler BE1-27 7RW600 and 7RW80 7RW60000-4EA00-0DA0 and 7RW8020-5EC96-1DA0+L0G<br />

Basler BE1-59 7RW600 and 7RW80 7RW60000-4EA00-0DA0 and 7RW8020-5EC96-1DA0+L0G<br />

Basler BE1-27/59 7RW600 and 7RW80 7RW60000-4EA00-0DA0 and 7RW8020-5EC96-1DA0+L0G<br />

Basler BE1-81O/U 7RW600 and 7RW80 7RW60000-4EA00-0DA0 and 7RW8020-5EC96-1DA0+L0G<br />

GE IAV 7RW600 and 7RW80 7RW60000-4EA00-0DA0 and 7RW8020-5EC96-1DA0+L0G<br />

GE IFV 7RW600 and 7RW80 7RW60000-4EA00-0DA0 and 7RW8020-5EC96-1DA0+L0G<br />

GE MIV 7RW600 and 7RW80 7RW60000-4EA00-0DA0 and 7RW8020-5EC96-1DA0+L0G<br />

GE NGV 7RW600 and 7RW80 7RW60000-4EA00-0DA0 and 7RW8020-5EC96-1DA0+L0G<br />

GE DFF 7RW600 and 7RW80 7RW60000-4EA00-0DA0 and 7RW8020-5EC96-1DA0+L0G<br />

GE MFF 7RW600 and 7RW80 7RW60000-4EA00-0DA0 and 7RW8020-5EC96-1DA0+L0G<br />

GE SFF 7RW600 and 7RW80 7RW60000-4EA00-0DA0 and 7RW8020-5EC96-1DA0+L0G<br />

*Siemens catalog numbers in Bold are the preferred equivalent model.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-33


Replacement Breakers & Retrofit Products<br />

Medium-voltage Replacement Circuit Breakers<br />

General<br />

14<br />

SWITCHGEAR<br />

Ratings from 5–38 kV, 250–1500 MVA,<br />

1200-3000 Amperes<br />

Replacement circuit breakers provide a<br />

cost-effective way to upgrade your<br />

system capabilities while saving you from<br />

costly maintenance and lost productivity<br />

and preserving your investment in<br />

existing cubicles and cables.<br />

Whether your equipment was originally<br />

manufactured by Allis-Chalmers,<br />

Westinghouse, GE, Federal Pacific, ITE,<br />

or another manufacturer, we will assist<br />

you to evaluate the Siemens replacement<br />

options which best meet your needs.<br />

Why Replacement Breakers?<br />

n Increased Reliability and Performance<br />

n Reduced Operating and Maintenance<br />

Expenditures<br />

n Reduced Downtime, Minimal<br />

Changeover Time During Upgrade<br />

n Preserved Investment in Existing<br />

Cubicles<br />

n Improved Employee and<br />

Environmental Safety<br />

Why Siemens?<br />

Siemens Offers the Best Vacuum Circuit<br />

Breaker in the Industry.<br />

n Superior Performance, Longer Service<br />

Life<br />

– 10,000 full load operation, 10-year<br />

maintenance cycle on replacement<br />

circuit breakers with 3AH operator<br />

n Standard Operator on All Siemens<br />

Replacement, Medium-voltage<br />

Distribution, and Outdoor Vacuum<br />

Circuit Breakers<br />

n Extensive Replacement Breaker<br />

Experience – 750+ projects since<br />

1983<br />

– Over 400,0000 3AF/H series circuit<br />

breakers in service worldwide<br />

– Nuclear Class 1E Rated (350+<br />

breakers)<br />

n Full Range of Service Capabilities by<br />

Skilled Factory-Trained Engineers and<br />

Technicians<br />

Siemens Medium-voltage Replacement Circuit Breakers<br />

The following circuit breakers are available as pre-engineered designs. Other<br />

manufacturers, models, and ratings can be engineered by Siemens.<br />

Transformer Protection<br />

Manufacturer Model kV Ratings<br />

MVA<br />

AMP<br />

Allis-Chalmers AM 5 150 1200, 2000<br />

(All Air-Magnetic) 250 1200, 2000<br />

MB 7 250 1200, 2000<br />

500 1200, 2000<br />

MC/MCV 15 150 1200<br />

250 1200, 2000<br />

500 1200, 2000<br />

MA 5 250 1200, 2000<br />

350 1200, 2000<br />

FA 5 350 3000<br />

FB 7 500 1200, 2000, 3000<br />

FC/FCV 15 500 1200, 2000<br />

750 1200, 2000<br />

1000 1200, 2000, 3000<br />

Siemens 3AF(H2), GMI, GMSG 5 250 1200, 2000<br />

350 1200, 2000, 3000<br />

7.5 500 1200, 2000, 3000<br />

15 500 1200, 2000<br />

750 1200, 2000<br />

1000 1200, 2000, 3000<br />

GE Magneblast (AMH) 4.16 250 600, 1200, 2000<br />

(All Air-Magnetic) Magneblast (AM) 2.4 100 600, 1200, 2000<br />

150 600, 1200, 2000<br />

4.16 100 600, 1200, 2000<br />

150 600, 1200, 2000<br />

250 600, 1200, 2000<br />

350 1200, 2000, 3000<br />

7.2 500 1200, 2000, 3000<br />

13.8 250 1200, 2000<br />

500 1200, 2000<br />

750 1200, 2000<br />

1000 1200, 2000, 3000<br />

Westinghouse DH 5 150 1200, 2000<br />

250 1200, 2000<br />

350 3000<br />

7.5 500 1200, 2000<br />

15 500 1200, 2000<br />

750 1200, 2000<br />

1000 1200, 2000, 3000<br />

DHP 5 350 1200, 2000<br />

7.5 500 1200, 2000<br />

15 500 1200, 2000<br />

750, 750C 1200, 2000<br />

1000 1200, 2000<br />

ITE HV 5 100 600, 1200<br />

150 600, 1200<br />

250 600, 1200<br />

HK 7.5 500 1200, 2000<br />

15 500 1200, 2000<br />

750 1200, 2000<br />

1000 1200, 2000<br />

Federal Pacific DST2 5 250 1200, 2000<br />

7.5 500 1200, 2000<br />

15 500 1200, 2000<br />

750 1200, 2000<br />

MOP 27 1000 1200<br />

McGraw Edison PSD 15 501 1200<br />

502 2000<br />

751 1200<br />

5-MSV (replacement for Allis-Chalmers MA)<br />

14-34<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Replacement Breakers & Retrofit Products<br />

SARRACS Safety Remote Breaker Racking System<br />

General<br />

In addition to eliminating the need for arc flash<br />

suits during racking, SARRACS also streamlines<br />

the procedure. First, the unit is positioned<br />

and secured. Then, the operator connects the<br />

breaker’s racking mechanism to SARRACS’<br />

Racking Adaptor.<br />

With the Operator’s Station in hand, the<br />

operator moves to a location safely beyond<br />

the flash zone. The object, switchgear and<br />

breaker are selected on the touch screen. Next,<br />

the starting position is input and the racking<br />

operation initiated.<br />

As the breaker is being racked, the operator<br />

receives precise real-time location and<br />

movement readings. Should a problem occur,<br />

fault-indicating screens are displayed, and the<br />

racking process is terminated immediately.<br />

14 SWITCHGEAR<br />

SARRACS (Safety Remote Breaker Racking System) provides increased<br />

protection for your most important assets – your personnel and your equipment<br />

Traditionally, breaker racking on<br />

an energized system required that<br />

operators work within the arc flash<br />

boundary, at risk from intense heat,<br />

percussion forces and airborne debris<br />

should a fault explosion occur. This led<br />

OSHA to establish the current standard<br />

that requires personnel to wear fullbody<br />

flash suits while performing<br />

racking procedures within the flash<br />

boundary.<br />

Now, with SARRACS, the operator<br />

can be positioned safely outside the<br />

arc flash boundary while racking any<br />

manufacturer’s breaker in or out of<br />

a live bus – eliminating the need for<br />

flash suits. In addition, the advanced<br />

technologies Siemens incorporated into<br />

SARRACS make racking more efficient,<br />

while limiting the potential for damage<br />

to electrical equipment during the<br />

procedure.<br />

Maximize safety<br />

Via the touch screen on the portable<br />

Operator’s Station, racking procedures<br />

can be controlled from a distance<br />

of up to 75 feet.<br />

Streamlining the process improves<br />

racking efficiency, reduces downtime<br />

SARRACS shortens breaker racking<br />

times by as much as 50% over<br />

traditional techniques. In addition, it<br />

allows expenses for related safety<br />

equipment, including flash suits, to be<br />

kept to a minimum.<br />

Siemens components deliver<br />

Siemens reliability<br />

SARRACS uses a three-phase gear<br />

motor to provide the power needed for<br />

racking and a digital encoder for precise<br />

position control and sensing. An AC<br />

variable-frequency drive operates all<br />

speed adjustments, over current limits<br />

and ramp functions.<br />

Unmatched control capabilities<br />

The advanced Siemens SIMATIC S7-200<br />

PLC provides the control required to limit<br />

damage to the breaker or cell that can<br />

be caused by equipment misalignment<br />

and jamming. This allows for:<br />

n Precise position tracking and<br />

movement monitoring to .001”<br />

n Accurate detection of breaker<br />

positions requiring high or<br />

low torque<br />

Total flexibility –<br />

one unit can take on any breaker<br />

n Simply adjust the elevation of the<br />

motor carriage to align the gear motor<br />

assembly to the racking mechanism<br />

on any manufacturer’s breaker<br />

n Profile Torque Protection technology<br />

uses the PLC to generate a distinct<br />

torque vs. position record for each<br />

individual breaker in a lineup. These<br />

torque profiles are stored in PLC<br />

memory using the Operator’s Station<br />

and can be easily updated anytime a<br />

breaker is being racked.<br />

Easily transport and store<br />

this robust yet compact unit<br />

With ball bearing wheels, casters and<br />

a transport handle, this lightweight<br />

unit (200 lbs.) is easily maneuvered in<br />

confined spaces.<br />

Get your operators up to speed<br />

in the shortest possible time<br />

Either at your facility or at one of our<br />

training centers, Siemens can provide<br />

professional training to ensure safe<br />

and efficient SARRACS operation.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-35


Field Services<br />

Start-up Commissioning Services<br />

General<br />

14<br />

SWITCHGEAR<br />

We realize that, even though our Totally<br />

Integrated Automation® and Totally<br />

Integrated Power® products are<br />

designed for quick and easy installation,<br />

your schedule may not allow you to<br />

allocate the resources and personnel<br />

necessary to get this equipment up and<br />

running when it is required.<br />

In today’s business environment, staff<br />

members are frequently overloaded, or<br />

they may be dedicated to other projects.<br />

Now, when you purchase new<br />

equipment from Siemens, you can add<br />

startup services at special rates. This will<br />

give you the additional help required to<br />

meet even the most pressing<br />

deadlines... at affordable rates. You can<br />

be confident that we will arrive at your<br />

door with the installation experience<br />

necessary to get your new general<br />

purpose drives, motor control center or<br />

switchgear properly started up and<br />

working when you need it.<br />

Factory-trained engineers will:<br />

n Startup your newly-purchased<br />

Siemens equipment<br />

n Test for operational functionality<br />

n Provide a written report detailing tests<br />

and services<br />

n Advise your team on upkeep and<br />

maintenance.<br />

In many cases, you will receive a oneyear<br />

parts warranty extension on your<br />

new equipment such as:<br />

n Motor control centers<br />

n General purpose variable speed drives<br />

n Low-voltage switchgear.<br />

Medium-voltage Switchgear Startup<br />

Service<br />

n Inspect anchorage, alignment and<br />

grounding<br />

n Check tightness of bolted bus joints<br />

n Measure and record critical distances<br />

such as contact gap<br />

n Perform mechanical operation tests on<br />

the operating mechanism<br />

n Perform a contact resistance test on<br />

the breaker vacuum contacts<br />

n Perform insulation resistance tests<br />

n Perform vacuum interrupter integrity<br />

(over-potential) tests<br />

n Perform insulation resistance test on<br />

all control wiring at 1000 volts DC<br />

n Verify trip, close, trip-free and antipump<br />

functions<br />

n More<br />

Low-voltage Switchgear Startup<br />

Service<br />

n Perform mechanical operational test<br />

n Check cell fit and element alignment<br />

n Check tightness of connections<br />

n Lubricate as required<br />

n Perform a contact resistance test<br />

n Perform an insulation resistance test<br />

at 1000 volts DC from pole-to-pole and<br />

from each pole-to-ground with breaker<br />

closed and across open contacts of<br />

each phase<br />

n Perform secondary current injection<br />

testing<br />

n More<br />

Switchboards and Power Switching<br />

Centers<br />

n Inspect for physical damage and<br />

nameplate compliance with single line<br />

diagram<br />

n Perform mechanical operational test.<br />

(circuit breakers, switches, etc.)<br />

n Check cell fit and element alignment<br />

n Check tightness of connections and<br />

lubricate<br />

n Perform a contact resistance test on<br />

RL/WL/SB breakers and power switches<br />

n Perform an insulation resistance test<br />

at 1000 volts DC from pole-to-pole and<br />

from each pole-to-ground with breaker<br />

or switch closed and across open<br />

contacts of each phase<br />

n Perform Secondary Current Injection<br />

Testing (RL/WL/SB breakers)<br />

n More<br />

For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office.<br />

14-36<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Field Services<br />

Start-up Commissioning Services<br />

General<br />

Motor Control Center Startup Service<br />

n Ensure that all protective devices have<br />

been properly set and locked<br />

n Review power fuse selection and<br />

installation procedures<br />

n Conduct a general physical inspection<br />

of MCC power and control<br />

connections. Check tightness of<br />

connections<br />

n Ensure incoming line power<br />

connections comply with UL/NEC<br />

requirements where applicable<br />

n Ensure that any special motor starting<br />

and running applications have been<br />

considered when selecting motor<br />

starter controls, and that main<br />

metering is functioning properly<br />

n Perform startup on drives, solid state/<br />

soft-start starters and other equipment<br />

n More<br />

General Purpose Variable Speed<br />

Drives Startup Service<br />

n Inspect electrical and mechanical parts<br />

after installation and wiring (per<br />

drawings)<br />

n Make final adjustments such as speed<br />

range, acceleration/deceleration and<br />

tuning to motor<br />

n Check starting, stopping, interlocking<br />

and sequencing (per drawings)<br />

n Check and adjust for purchased<br />

options such as bypass, braking, serial<br />

communications, encoder interface,<br />

and line filters<br />

n Verify power quality (MM440 units<br />

only)<br />

n More<br />

14 SWITCHGEAR<br />

Engineer-by-the-Day for new equipment purchases<br />

*Minimum purchase required. Extended warranty<br />

not vailable with Engineer-by-the-Day service.<br />

Now, you can take advantage of the<br />

expertise of a Siemens factory-trained<br />

engineer to startup your Siemens power<br />

distribution and control equipment<br />

purchases.<br />

Engineer-by-the-Day is available in<br />

complete one-day increments for setup<br />

of the following products*:<br />

n ACCESS power monitoring<br />

n Busway<br />

n Dry type transformers<br />

n Insulated case circuit breakers<br />

n Molded case circuit breakers<br />

n Panelboards<br />

n Sensitrip circuit breakers<br />

n Switchboards<br />

n Switches<br />

n More<br />

Siemens Industry is committed to<br />

ensuring that your equipment is up and<br />

running...when you need it. Siemens<br />

Industrial Services provides expert<br />

factoryauthorized equipment startup at<br />

a special rate when you purchase the<br />

service before your product is delivered.<br />

Get your equipment up and running on<br />

time. Contact your local distributor or<br />

Siemens Industry sales office to learn<br />

more.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-37


Field Services<br />

Power System Studies<br />

General/Selection<br />

14<br />

SWITCHGEAR<br />

Short Circuit Study<br />

Power system specialists from Siemens<br />

will determine the maximum duty that<br />

your system’s protective devices,<br />

transformers, and interconnections will<br />

be subjected to in the event of three<br />

phase and/or line-to-ground fault<br />

conditions. In addition, we will provide<br />

basic information required to establish<br />

protective relay settings.<br />

Coordination Study<br />

Under fault conditions, systems should<br />

isolate the faulted area to minimize<br />

disturbance to the remaining system,<br />

and simultaneously limit damage to<br />

equipment. We will review the<br />

characteristics of your protective<br />

devices, then provide the settings<br />

necessary to ensure that your system<br />

functions optimally should a fault occur.<br />

Harmonic Analysis<br />

As AC drives have become increasingly<br />

prevalent in industry, we have seen the<br />

introduction of destructive harmonics to<br />

many systems. The power quality<br />

experts from Siemens will determine the<br />

extent and severity of harmonics in your<br />

system, then recommend the<br />

appropriate means of limiting potential<br />

damage.<br />

Transient Stability Study<br />

This study is particularly valuable for<br />

facilities that generate their own power,<br />

and those with very large motors. Our<br />

power system specialists will study the<br />

transient response of rotating equipment<br />

following system disturbances, and<br />

analyze system behavior in relation to<br />

the power company tie.<br />

Protective Device Evaluation<br />

With the objective of achieving optimum<br />

protection, we will perform the<br />

necessary calculations required to select<br />

the interrupting rating of power fuses,<br />

circuit breakers, and other protective<br />

devices.<br />

Power Quality Assessment<br />

With the proliferation of sensitive<br />

electronic equipment in recent years,<br />

power quality has become a major<br />

concern for industry. We perform<br />

structured, step-by-step studies with<br />

timely diagnosis and expert solutions to<br />

the complex challenges of utility and<br />

end-user power quality issues.<br />

Arc Flash Study<br />

NFPA 70E recommends that an Arc<br />

Flash Hazard Analysis be performed prior<br />

to work on electrical equipment.<br />

Siemens will determine the incident<br />

energy levels, Arc Flash Boundary (AFB),<br />

and required level of Personal Protective<br />

Equipment (PPE).<br />

Load Flow Study<br />

This steady-state analysis of your<br />

system’s capability to supply the<br />

connected load will produce a listing of<br />

real and reactive power flow in each line<br />

or branch, and the bus voltages, under<br />

both normal and abnormal system<br />

conditions.<br />

Voltage Unbalance Study<br />

Voltage flicker and poor voltage<br />

regulation are a common concern on<br />

systems with large arc furnaces. The<br />

experts from Siemens use this study to<br />

develop comprehensive solutions that<br />

limit the effects of voltage irregularities<br />

and protect sensitive equipment.<br />

Grounding Study<br />

With the goal of ensuring proper<br />

protection and reducing the possibility of<br />

excessive transient overvoltages during<br />

line-to-ground faults, our engineers will<br />

determine and recommend the most<br />

appropriate form of system grounding<br />

protection (including solidstate, low<br />

resistance, and high resistance).<br />

With power system expertise and<br />

experience that comes from real-world<br />

successes, the specialized team of<br />

professional engineers and certified<br />

technicians from Siemens will help you:<br />

n Minimize downtime<br />

n Improve the safety of your operations<br />

for employees and sub-contractors<br />

n Optimize your system’s performance<br />

n Extend your equipment’s life cycle<br />

n Reallocate your valuable internal<br />

maintenance resources to your core<br />

business<br />

n Maximize the protection of sensitive<br />

electronics<br />

n Ensure your facility complies with<br />

applicable safety regulations<br />

In addition, the power system specialists<br />

from Siemens also provide the following:<br />

Power System Studies on<br />

“Equipment Release for Manufacture”<br />

n To ensure adequate interrupting rating,<br />

and to ensure that coordination<br />

capabilities are recognized<br />

Streamlined Power System<br />

Construction Studies (PSCS)<br />

n For devices being installed on<br />

construction projects<br />

For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office.<br />

14-38<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Field Services<br />

Arc Flash Study<br />

General<br />

Arc Flash Hazards<br />

In the fraction of a second that it takes<br />

copper to expand to vapor, an arc flash<br />

can generate skin-searing heat — four<br />

times hotter than the surface of the sun.<br />

Recent revisions to NFPA70E require<br />

that an Arc Flash Hazard Analysis be<br />

performed prior to working on or near<br />

electrical equipment containing exposed<br />

energized conductors. The analysis<br />

determines the arc flash boundaries<br />

(AFB), incident energy levels and the<br />

required level of personal protective<br />

equipment (PPE). The recommendations<br />

in the analysis can be used to determine<br />

hazards in your workplace. Implementing<br />

the recommendations will help protect<br />

your workers and help you satisfy OSHA<br />

requirements.<br />

The Siemens solution to<br />

minimize risks from arc flash<br />

hazards<br />

Working within NFPA and IEEE<br />

guidelines, our experienced power<br />

systems engineers will perform<br />

systematic and accurate Arc Flash Hazard<br />

Studies as follows:<br />

1. Short Circuit Calculations<br />

Siemens will either use your data, or<br />

make calculations for you, to identify<br />

bolted and arcing fault levels at key<br />

points in a power distribution system.<br />

2. Protective Device Coordination<br />

Using the customer’s electrical<br />

systems coordination study, Siemens<br />

determines the duration of the arcing<br />

faults.<br />

3. Arc Flash Hazard Calculations<br />

The incident energy level, the flash<br />

hazard boundary, and the PPE required<br />

are then calculated for each location.<br />

4. Documentation<br />

The information above is compiled for<br />

you into a comprehensive report,<br />

which contains information necessary<br />

to comply with regulatory<br />

requirements.<br />

5. Unsafe Work Locations<br />

The report will identify work locations<br />

having incident energy levels in excess<br />

of available PPE ratings.<br />

6. Arc Flash Hazard Mitigation<br />

Recommendations will be made to<br />

minimize Arc Flash Hazards by<br />

changes in system protection or<br />

operational procedures.<br />

7. Arc Flash Hazard Labels<br />

In addition to the report, our customers<br />

will receive a field label containing the<br />

flash hazard boundary distance,<br />

incident energy level, PPE category<br />

and shock hazard for each location.<br />

Implementing<br />

recommendations from a<br />

Siemens Arc Flash Hazard<br />

Study can bring you the<br />

following benefits:<br />

n Improve employee safety<br />

n Improve your electrical system<br />

n Provide safety information to<br />

subcontractors<br />

n Assist in compliance with regulations<br />

n Provide you with documentation that<br />

may bring about reductions in workers<br />

compensation and insurance rates<br />

Turn to Siemens for Arc Flash Hazard<br />

Studies, comprehensive safety training<br />

and other related services that will<br />

enhance the safety of your personnel<br />

and the reliability of your operation.<br />

SARRACS — Complete arc flash<br />

protection for switchgear racking.<br />

After completion of your Arc Flash Hazard<br />

Study and Equipment Labeling efforts,<br />

why not consider another aspect to your<br />

personnel safety initiatives? Why not<br />

consider Siemens’ SARRACS remote<br />

circuit breaker racking system? Racking<br />

medium-voltage circuit breakers (>1000V)<br />

into and out of a live bus is one instance<br />

where the PPE required may not be<br />

adequate to protect personnel from arc<br />

flash. Siemens SARRACS effectively<br />

removes the operator from the arc flash<br />

boundary by allowing for remote<br />

installation or removal. In addition,<br />

SARRACS provides torque monitoring to<br />

detect improper breaker connection.<br />

14 SWITCHGEAR<br />

For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-39


Secondary Unit Substations<br />

Overview<br />

General<br />

14<br />

SWITCHGEAR<br />

Siemens offers a wide variety of unit<br />

substation designs to meet customer<br />

requirements. A unit substation<br />

consists of one or more transformers<br />

mechanically and electrically<br />

connected to and coordinated in<br />

design with one or more switchgear or<br />

switchboard assemblies. A secondary<br />

unit substation is defined as a unit<br />

substation whose outgoing section is<br />

rated below 1000 volts.<br />

A typical secondary unit substation<br />

consists of three sections:<br />

n Primary: an incoming section that<br />

accepts incoming high voltage (2400 to<br />

13,800 volts) line<br />

n Transformer: section that transforms<br />

incoming voltage down to utilization<br />

voltage (600 volts or less)<br />

n Secondary: an outgoing section that<br />

distributes power to outgoing feeders<br />

and provides protection for these<br />

feeders (600 volts and less)<br />

Standard secondary unit substations<br />

consist of:<br />

n Medium-voltage Primary<br />

n Transformer<br />

n Low-voltage Secondary<br />

Siemens also offers low-voltage unit<br />

substations with:<br />

n Low-voltage Primary<br />

n Transformer<br />

n Low-voltage Secondary<br />

The primary reason for using a secondary<br />

unit substation is to bring power as close<br />

as possible to the center of the loads.<br />

Another reason is that it provides a<br />

system design concept incorporating a<br />

wide variety of components that permits<br />

tailoring equipment to the needs of the<br />

application. A secondary unit substation<br />

provides<br />

n Reduced power losses<br />

n Better voltage regulation<br />

n Improved service continuity<br />

n Increased functional flexibility<br />

n Lower installation cost<br />

n Efficient space utilization<br />

Every component and assembly of<br />

secondary unit substations are designed<br />

and engineered as an integral part of a<br />

complete system.<br />

Primary Switch<br />

Liquid Filled Transformer<br />

Switchboard with WL Encased<br />

Systems Breakers<br />

Primary Switch<br />

Dry Type Transformer<br />

Type SB3 Switchboard with<br />

Fusible Switches<br />

Primary Switch<br />

Liquid Filled Transformer<br />

Type WL Low-voltage<br />

Switchgear<br />

For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office.<br />

14-40<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Siemens Unit Substation Solutions<br />

5 – 15 kV SIEBREAK Metal-Enclosed Load Interrupter Switchgear<br />

SIEBREAK Specifications<br />

Standard<br />

n Indoor type 1 enclosure<br />

n Large 8” x 18” (203 mm x 457 mm)<br />

viewing window<br />

n Hinged, grounded metal barrier in<br />

front of switch blades<br />

n Provisions for key interlocking<br />

n Upper and lower ventilation louvers<br />

n Glass-polyester bus supports<br />

n Non-corrosive nameplate<br />

n Space heater with thermostat<br />

n NEMA CC1 hole patterns for cable<br />

termination.<br />

n Meets or exceeds applicable<br />

standards from ANSI, IEEE, CSA,<br />

EEMAC, and NEMA.<br />

Optional<br />

n UL or C-UL Listing<br />

n Current-limiting or explusion fuses<br />

n Indoor type 2 drip-proof enclosure<br />

n Indoor type 12 dust-resistant<br />

enclosure<br />

n Outdoor non-walk-in type 3R<br />

enclosure<br />

n Motor-operated mechanism<br />

n Tin-plated copper bus.<br />

n Auxiliary switches (2 NO-2 NC)<br />

n Mimic bus<br />

n Ground studs<br />

n Screens and filters (indoor)<br />

14 SWITCHGEAR<br />

Dimensions<br />

Single Duplex Selector c Front access c<br />

Indoor a Width b 36 inches (914mm) 72 inches (1829 mm) 36 inches (914mm) 60 inches (1524 mm)<br />

Depth 62 inches (1581 mm) 72 inches (1829 mm) 56 inches (1422 mm)<br />

Height<br />

92 inches (1575 mm)<br />

Indoor a Depth<br />

72 inches (1829 mm)<br />

Width bde 54 inches (1372 mm) 90 inches (2286 mm) 54 inches (1372 mm) not available<br />

Height<br />

Notes:<br />

a Incoming cables available top or bottom entry<br />

b Transformer connection available left side or right side<br />

c Auxiliary devices not available with selector and front access<br />

d Outdoor width include 18-inch (457 mm) liquid-filled transformer termination section<br />

e For outdoor dry type transformer, add 2.67 inches (67 mm) to the width for termination<br />

105 inches (2667 mm)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-41


Siemens Unit Substation Solutions<br />

5 – 15 kV SIEBREAK Metal-Enclosed Load Interrupter Switchgear<br />

Technical Data<br />

Rated voltage Type 5 kV 15 kV<br />

Rated frequency<br />

50/60 Hz<br />

Rated duration power frequency withstand voltage 19 kV 36 kV<br />

Rated lightning impulse withstand voltage (BIL) 60 kV 95 kV<br />

Fuse short circuit current rating Current Limiting 50 kA 50 kA<br />

Expulsion 37.5 29.4<br />

Switch rating Continuous Current 600 A and 1200 A<br />

Interrupting rms<br />

25 kA and 38 kA<br />

Momentary rms<br />

40 kA, 61 kA, 80 kA<br />

Assembly rating Main bus continuous current 1200 A and 2000 A<br />

Short-time 2 second<br />

25kA and 38 kA<br />

14<br />

SWITCHGEAR<br />

Fuse Selection Table<br />

System<br />

Voltage<br />

Fuse<br />

type a<br />

Symmetrical<br />

Interrupting kA<br />

Equivalent<br />

MVA 500 kVA 750 kVA 1000 kVA 1500 kVA 2000 kVA 2500 kVA 3000 kVA 3750 kVA 5000 kVA<br />

2400 CL-14 50 260 200 250 400 500 600 — — — —<br />

RBA400 37.5 155 200 250 400 — — — — — —<br />

RBA800 37.5 155 — — — 540 720 — — — —<br />

4160 CL-14 50 450 100 125 200 300 500 500 — — —<br />

RBA400 37.5 270 100 150 200 300 400 — — — —<br />

RBA800 37.5 270 — — — — 540 540 — —<br />

4800 CL-14 50 520 80 125 200 250 400 450 — — —<br />

RBA400 37.5 310 100 125 200 250 400 400 — — —<br />

RBA800 37.5 310 — — — — — — 540 — —<br />

7200 CL-14 50 620 65 80 125 200 250 300 — — —<br />

RBA400 29.4 365 65 80 125 200 250 300 400 — —<br />

RBA800 29.4 365 — — — — — — — 450 —<br />

12470 CL-14 50 1079 40 50 65 100 125 200 200 250 —<br />

RBA400 29.4 635 40 50 80 100 150 200 200 250 400<br />

RBA800 29.4 635 — — — — — — — — —<br />

13200 CL-14 50 1143 30 50 65 100 125 150 200 250 300<br />

RBA400 29.4 672 30 50 65 100 125 150 200 250 300<br />

RBA800 29.4 672 — — — — — — — — —<br />

13800 CL-14 50 1195 30 50 65 100 125 150 200 250 300<br />

RBA400 29.4 702 30 50 65 100 125 150 200 250 300<br />

RBA800 29.4 702 — — — — — — — — —<br />

Notes:<br />

a Incoming cables available top or bottom entry<br />

b Transformer connection available left side or right side<br />

c Auxiliary devices not available with selector and front access<br />

d Outdoor width include 18-inch (457 mm) liquid-filled transformer termination section<br />

e For outdoor dry type transformer, add 2.67 inches (67 mm) to the width for termination<br />

14-42<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Siemens Unit Substation Solutions<br />

Overview<br />

Siemens offers a wide variety of<br />

unit substation designs to meet<br />

virtually any customer requirement.<br />

A unit substation consists of one<br />

or more transformers mechanically<br />

and electrically connected to, and<br />

coordinated with, one or more<br />

switchgear or switchboard assemblies.<br />

A secondary unit substation is defined<br />

as a unit substation whose outgoing<br />

section is rated below 1,000 volts.<br />

A typical secondary unit substation<br />

consists of three sections:<br />

n Primary: depending on the specific<br />

application, this section accepts<br />

medium-voltage (2,400 to 27,600<br />

volts) incoming power<br />

n Transformer: reduces incoming<br />

voltage to utilization voltage (600 volts<br />

or less)<br />

n Secondary: distributes power to,<br />

and provides protection for, outgoing<br />

feeders (600 volts and less).<br />

Primary Switch Dry-Type Transformer Type SB3 Switchboard<br />

14 SWITCHGEAR<br />

The key benefit of a secondary unit<br />

substation is that it economically<br />

brings power as close as possible to<br />

the loads, minimizing power loss and<br />

maximizing voltage regulation. It also<br />

enhances flexibility, using a system<br />

design concept that integrates a wide<br />

variety of components to tailor the<br />

equipment to the specific needs of<br />

each application.<br />

Every component or assembly utilized<br />

in secondary unit substations is<br />

engineered to be an integral part of a<br />

complete system.<br />

A secondary unit substation helps<br />

you:<br />

n Reduce power losses<br />

n Enhance voltage regulation<br />

n Improve service continuity<br />

n Increase functional flexibility<br />

n Lower installation costs<br />

n Minimize space utilization.<br />

Primary Switch Liquid Filled Type Transformer Type SB3 Switchboard<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-43


Siemens Unit Substation Solutions<br />

Transformers: Dry Type — VPI/VPE<br />

4 in. 4 in.<br />

D<br />

Plan view<br />

W<br />

HV-terminal<br />

Danger<br />

Fan<br />

control<br />

panel<br />

H<br />

HV<br />

air<br />

terminal<br />

chamber<br />

(optional)<br />

N.P.<br />

Fan<br />

control<br />

when req.<br />

LV<br />

air<br />

terminal<br />

chamber<br />

(optional)<br />

Front<br />

Ground<br />

bus<br />

14<br />

SWITCHGEAR<br />

18 in.<br />

(457 mm)<br />

Std.<br />

Front view<br />

indoor<br />

18 in.<br />

(457 mm)<br />

Std.<br />

Type = VPI/VPE<br />

Primary Volts = 2400-13800<br />

Sec_Volts = 208-600<br />

Temperature Rise = 150C for Aluminum Windings, 80/115C for Copper Windings<br />

Standard kV BIL (HV/LV) = 60/30 for Aluminum Windings, 95/30 for Copper Windings<br />

W<br />

Front view<br />

outdoor<br />

Table 1 Low-voltage Switchgear or Switchboard Coordination<br />

Winding Material<br />

KVA<br />

Height<br />

(Inches)<br />

Width<br />

(Inches)<br />

Depth<br />

(Inches)<br />

Weight<br />

(Pounds)<br />

Aluminum 300 90 90 54 4600<br />

Aluminum 500 90 90 54 4800<br />

Aluminum 750 90 90 54 5800<br />

Aluminum 1000 90 102 60 7000<br />

Aluminum 1500 96 102 60 9200<br />

Aluminum 2000 102 102 60 11000<br />

Aluminum 2500 108 112 60 12200<br />

Aluminum 3000 108 118 60 14100<br />

Aluminum 3750 112 126 66 15800<br />

Aluminum 5000 118 132 66 17000<br />

Copper 300 90 90 54 6000<br />

Copper 500 90 96 60 6400<br />

Copper 750 90 102 60 8000<br />

Copper 1000 96 102 60 9700<br />

Copper 1500 102 108 60 13200<br />

Copper 2000 108 112 60 17400<br />

Copper 2500 118 126 60 19000<br />

Copper 3000 118 132 60 22000<br />

Copper 3750 126 132 66 27000<br />

Copper 5000 132 138 66 30000<br />

14-44<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Siemens Unit Substation Solutions<br />

Transformers: Dry Type — Cast Coil<br />

Type = Cast Coil<br />

Primary Volts = 2400-13800<br />

Sec_Volts = 208-600<br />

Temperature Rise = 80/115C for Both Aluminum & Copper Windings<br />

Standard kV BIL (HV/LV) = 60/30 for Aluminum Windings, 95/30 for Copper Windings<br />

Table 2 Low-voltage Switchgear or Switchboard Coordination<br />

Winding Material<br />

KVA<br />

Height<br />

(Inches)<br />

Width<br />

(Inches)<br />

Depth<br />

(Inches)<br />

Weight<br />

(Pounds)<br />

Aluminum 300 90 90 54 5500<br />

Aluminum 500 90 90 54 6300<br />

Aluminum 750 90 96 60 7800<br />

Aluminum 1000 96 102 60 9500<br />

Aluminum 1500 102 108 60 11500<br />

Aluminum 2000 108 112 60 13800<br />

Aluminum 2500 112 126 60 16200<br />

Aluminum 3000 118 132 60 19200<br />

Aluminum 3750 126 138 66 25000<br />

Aluminum 5000 132 144 66 28000<br />

Copper 300 90 90 60 6200<br />

Copper 500 90 96 60 7000<br />

Copper 750 90 102 60 9100<br />

Copper 1000 96 112 60 10600<br />

Copper 1500 102 118 60 14300<br />

Copper 2000 108 118 66 18200<br />

Copper 2500 118 126 66 19500<br />

Copper 3000 126 132 66 23500<br />

Copper 3750 126 144 66 28000<br />

Copper 5000 132 160 66 35000<br />

14 SWITCHGEAR<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-45


Siemens Unit Substation Solutions<br />

Transformers: Liquid Filled Type<br />

Top view<br />

Elevation<br />

H<br />

G<br />

8<br />

J<br />

H 3<br />

H 2<br />

H 1<br />

X 3<br />

X 2<br />

X 1<br />

X 0<br />

C<br />

D<br />

E<br />

F<br />

A<br />

SWITCHGEAR<br />

14<br />

B<br />

Unit Type Substation Transformer<br />

Primary Volts = 25kV and below, Secondary Voltage = 5kV and below<br />

Table 3 Liquid-Filled 55/65 °C Rise<br />

Aluminum Windings<br />

Copper Windings<br />

Drawing Dimensions (in.)<br />

kVA A B C D E F G H J<br />

Gallons Of<br />

Fluid<br />

Approx. Total<br />

Weight (lbs.)<br />

(With Fluid)<br />

Gallons Of<br />

Fluid<br />

Approx. Total<br />

Weight (lbs.)<br />

(With Fluid)<br />

500 66 51 26 52 45 45 30 60 35 300 5600 310 5900<br />

750 75 59 26 52 55 55 34 68 35 360 7000 370 7400<br />

1000 75 67 26 52 55 55 38 76 35 420 8400 430 8800<br />

1500 75 59 59 80 55 55 34 68 35 400 9500 420 10000<br />

2000 85 67 67 90 55 55 38 76 39 520 12000 500 12800<br />

2500 85 75 68 92 55 55 42 84 41 570 14600 590 14900<br />

3750 85 75 70 120 65 65 42 84 45 790 20500 830 21500<br />

5000 99 87 72 144 65 65 48 96 49 1050 26000 1090 28000<br />

7500 99 95 74 148 75 75 52 104 53 1320 35000 1360 37000<br />

10,000 99 103 76 152 75 75 56 112 57 1740 43000 1780 45000<br />

12,000 99 103 82 164 75 75 56 112 61 1850 49000 1880 50000<br />

Weights, gallons of fluid and dimensions are for reference only, and not for construction.<br />

Please contact Siemens Industry Inc. for exact dimensions<br />

14-46<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Siemens Unit Substation Solutions<br />

Type WL Low-voltage Switchgear Substation Secondaries<br />

Siemens type WL low-voltage, metalenclosed<br />

switchgear is designed,<br />

constructed and tested to provide<br />

superior power distribution, power<br />

monitoring and control. At the heart of<br />

the type WL low-voltage switchgear<br />

is the world class Siemens type WL<br />

breaker. Siemens type WL low-voltage<br />

switchgear can be utilized in the<br />

following applications:<br />

n Industrial<br />

n Institutional<br />

n Critical power<br />

n Utility and co-generation<br />

n Commercial.<br />

Product Scope<br />

n Equipment ratings:<br />

635 Vac maximum<br />

Three-phase, three-wire<br />

Three-phase, four-wire<br />

50/60 Hz<br />

6,000 A maximum horizontal bus<br />

5,000 A maximum vertical bus.<br />

n Enclosure options:<br />

NEMA 1 indoor<br />

NEMA 3R outdoor walk-in<br />

NEMA 3R outdoor non walk-in.<br />

14 SWITCHGEAR<br />

Exclusive features<br />

Generator/utility protection sets<br />

24/7/365 power availability is critical<br />

for some systems. On-site generation<br />

capabilities are becoming more and<br />

more common. Type WL digital<br />

electronic trip units allow the system<br />

designer to precisely tailor trip settings<br />

for the most demanding requirements.<br />

The Siemens type WL 776 trip unit<br />

allows one set of trip settings for a fully<br />

loaded utility feed and, with a simple<br />

contact closure, the trip unit toggles<br />

to a second trip set tailored to provide<br />

optimal generator protection. The wide<br />

range of settings allows the type WL<br />

to provide protection for a minimal<br />

generator capacity for only essential<br />

loads, through full backup for an entire<br />

facility. This dual utility/generator<br />

protection capability in a single circuit<br />

breaker allows the system designer<br />

unparalleled, cost effective flexibility.<br />

For more information, visit our web site at:<br />

www.usa.siemens.com/switchgear.<br />

Extended instantaneous protection (EIP)<br />

This patent pending type WL trip unit<br />

feature allows the system designer to<br />

achieve full selective trip coordination up<br />

to the short-time rating of the frame, while<br />

also allowing application of the circuit<br />

breaker up to the interrupting rating of the<br />

frame. EIP allows the type WL breaker<br />

to be applied up to the full withstand<br />

rating of the circuit breaker, for complete<br />

coordination, with a minus 0% short-time<br />

band tolerance up to 85 kA on Frame Size<br />

II and 100 kA on Frame Size III.<br />

Above fault currents of 20-percent higher<br />

than the full short-time rating, the type<br />

WL circuit breaker is self-protecting, and<br />

the EIP function will trip the circuit breaker<br />

instantly to protect the frame and the<br />

system from these extremely high currents<br />

(as high as 150 kA on Frame Size III). An<br />

added benefit is that arc flash energy is<br />

greatly reduced in this high- current region<br />

due to EIP’s instantaneous trip response.<br />

Industry standards<br />

Type WL switchgear with power circuit<br />

breakers are designed, tested and<br />

constructed in accordance with:<br />

n UL 1558—Metal-Enclosed Lowvoltage<br />

Power Circuit Breaker<br />

Switchgear<br />

n ANSI C37.20.1—Metal-Enclosed<br />

Low- Voltage Power Circuit Breaker<br />

Switchgear.<br />

Type WL drawout circuit breakers are<br />

designed for continuous operation<br />

at 100-percent of their current rating<br />

without the need for external heat<br />

sinks, and are in accordance with:<br />

n UL 1066—Low-voltage AC and DC<br />

Power Circuit Breakers Used in<br />

Enclosures<br />

n ANSI C37.13—Low-voltage AC Power<br />

Circuit Breakers Used in Enclosures.<br />

Switchgear Secondary<br />

Note: See Pages 14-52 to 14-72 for complete<br />

details concerning WL Low-voltage<br />

Switchgear unit substation secondaries.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-47


Siemens Unit Substation Solutions<br />

Switchboard Substation Secondaries<br />

14<br />

SWITCHGEAR<br />

Product Overview<br />

Siemens modular front connected<br />

switchboard design provides a broad<br />

range of features and capabilities for<br />

a wide range of applications.<br />

Every aspect of design of Siemens<br />

switchboards has been aimed at<br />

improving layout convenience,<br />

reducing installation costs and<br />

minimizing the impact and cost of<br />

changes to the system.<br />

Siemens switchboards provide a<br />

rugged design and the flexibility<br />

necessary in electrical systems for all<br />

types of applications, some examples<br />

are:<br />

n Industrial plants<br />

n High-rise complexes<br />

n Hospitals<br />

n Commercial buildings<br />

Standards and Certifications<br />

Siemens switchboards are designed,<br />

tested and constructed in accordance<br />

with:<br />

n UL891 – Switchboards<br />

n NEMA PB-2<br />

n Seismially qualified<br />

n Other equipment is UL listed as<br />

applicable<br />

Features & Benefits<br />

Siemens switchboards ratings and<br />

features include:<br />

n Up to 6000 ampere main bus rating<br />

n Up to 600 volts AC<br />

n Bus bracing up to 200KAIC<br />

n Copper or aluminum bussing<br />

n Temperature or density rated bussing<br />

n Type 1 and Type 3R enclosures<br />

n Main and branch circuit breakers and<br />

fusible switches<br />

n Thermal magnetic and solid state<br />

circuit breakers<br />

n Surge protective devices<br />

n Utility metering provisions<br />

n ACCESS power monitoring on mains<br />

and branches<br />

n Ground fault protection on mains and<br />

branches<br />

n Busway and transformer connections<br />

n Protective relaying<br />

n Two and three device autothrowover<br />

scheme<br />

Further Switchboard<br />

Information<br />

See Section 13 for complete details<br />

concerning SB3 front-connected<br />

switchboard unit substation<br />

secondaries.<br />

14-48<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Siemens Unit Substation Solutions<br />

Indoor Dry Type Transformer<br />

Diagrams<br />

Indoor - dry transformer<br />

92.0 (2,337)<br />

Swgr<br />

gnd<br />

(X0)<br />

Five PEM nuts<br />

3/ 8 -16 for<br />

joining<br />

switchgear<br />

with<br />

transformer<br />

9.0 9.0<br />

(229) (229)<br />

H1 H2 H3<br />

(X1)(X2)<br />

(X3)<br />

18.5 (470)<br />

56.0 (1,422), 62.0 (1,575), 72.0 (1,829), or<br />

82.0 (2,083) transformer to left of switchgear<br />

(flush front transformer mounting)<br />

A<br />

36.0 (914)<br />

A<br />

Five PEM nuts<br />

3/ 8 -16 for<br />

joining<br />

switchgear<br />

with<br />

transformer<br />

9.0 9.0<br />

(229) (229)<br />

H1 H2 H3<br />

(X3)(X2)<br />

(X1)<br />

18.5 (470)<br />

Swgr<br />

gnd<br />

(X0)<br />

92.0 (2,337)<br />

56.0 (1,422), 62.0 (1,575), 72.0 (1,829), or<br />

82.0 (2,083) transformer to left of switchgear<br />

(flush front transformer mounting)<br />

14 SWITCHGEAR<br />

Footnotes:<br />

1. This arrangement applies to indoor SIEBREAK switch 5 kV-15 kV up to 1,200 A termination with dry-type transformer termination.<br />

2. Filler strips at the ends of the transformer must be provided by the transformer supplier in case the transformer exceeds 92” (2,337<br />

mm) height and 56” (1,422 mm) depth.<br />

3. If cables are to be used for connections to transformer, transformer supplier to provide and install cable connections including lugs<br />

and insulation on terminals if required. Maximum 2 x 500 kcmil cables per phase.<br />

4. If bus bars are to be used for connections to transformer, transformer supplier to provide and install required bus connections.<br />

Transformer supplier also to provide and install flex connectors for connections to switchgear as well as insulation for flex<br />

connectors.<br />

5. Connect switchgear ground when continuous ground is required.<br />

6. Transformer supplier to provide necessary hardware (except PEM nuts) for joining switchgear with transformer.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-49


Siemens Unit Substation Solutions<br />

Indoor Liquid Filled Transformer<br />

Diagrams<br />

Indoor - liquid-filled transformer<br />

14<br />

SWITCHGEAR<br />

92.0 (2,337)<br />

c Ltransformer<br />

throat<br />

H1 H2 H3<br />

(X1)(X2)<br />

(X3)<br />

8.0 8.0<br />

(203) (203)<br />

Swgr<br />

gnd<br />

(X0)<br />

33.55 (852)<br />

56.0 (1,422), 62.0 (1,575),<br />

72.0 (1,829), or 82.0 (2,083)<br />

transformer to left of switchgear<br />

Termination on<br />

left-hand side<br />

symmetrical to<br />

right-hand side<br />

except phase<br />

reversal<br />

c Ltransformer<br />

throat<br />

55.0 (1,397)<br />

Z<br />

18.0<br />

(457)<br />

36.0<br />

(914)<br />

18.0<br />

(457)<br />

Z<br />

Transformer<br />

flange<br />

Termination on<br />

right-hand side<br />

symmetrical to<br />

left-hand side<br />

except phase<br />

reversal<br />

55.0 (1,397)<br />

H1 H2 H3<br />

(X3)(X2)<br />

(X1)<br />

8.0<br />

(203)<br />

L<br />

8.0<br />

(203)<br />

c transformer<br />

throat<br />

33.55 (852)<br />

56.0 (1,422)<br />

92.0 (2,337)<br />

Footnotes:<br />

1. This arrangement applies to indoor SIEBREAK switch 5 kV-15 kV up to 1,200 A termination with liquid-filled type transformer<br />

termination.<br />

2. This arrangement applies to bar-type connection to transformer only.<br />

3. Filler strips at the ends of the transformer must be provided by the transformer supplier in case the transformer exceeds 92” (2,337<br />

mm) height and 56” (1,422 mm) depth.<br />

4. Transformer supplier to provide necessary hardware (except PEM nuts) for joining switchgear with transformer.<br />

14-50<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Selection and Application Guide | SIEBREAK Metal-Enclosed Interrupter Switchgear<br />

Siemens Unit Substation Solutions<br />

Outdoor Liquid Type Transformer<br />

Diagrams<br />

Outdoor - liquid-filled transformer<br />

98.9 (2,512)<br />

52.8 (1,341)<br />

Swgr gnd<br />

(X0)<br />

c Ltransformer<br />

throat<br />

H3 H2 H1<br />

(X1)(X2)<br />

(X3)<br />

8.0 8.0<br />

(203) (203)<br />

33.5 (851)<br />

72.0 (1,829) transformer to<br />

left of switchgear<br />

105 (2,667)<br />

Termination on<br />

left-hand side<br />

symmetrical to<br />

right-hand side<br />

except phase<br />

reversal<br />

c Ltransformer<br />

Z<br />

throat<br />

61.0 (1,549)<br />

18.0<br />

(457)<br />

36.0<br />

(914)<br />

18.0<br />

(457)<br />

Z<br />

Transformer<br />

flange<br />

Termination on<br />

right-hand side<br />

symmetrical to<br />

left-hand side<br />

except phase<br />

reversal<br />

Five 3/ -16 8<br />

PEM nuts for<br />

joining<br />

switchgear<br />

with<br />

transformer<br />

61.0 (1,549)<br />

105.0 (2,667)<br />

64.12 (1,629)<br />

H1 H2 H3<br />

(X3)(X2)<br />

(X1) Swgr<br />

gnd<br />

(X0)<br />

8.0<br />

(203)<br />

L<br />

33.55 (852)<br />

8.0<br />

(203)<br />

c transformer<br />

throat<br />

72.0 (1,829) transformer<br />

on right side of switchgear<br />

98.7 (2,507)<br />

14 SWITCHGEAR<br />

Footnotes:<br />

1. This arrangement applies to outdoor SIEBREAK switch 5 kV-15 kV up to 1,200 A termination with liquid-filled type<br />

transformer termination.<br />

2. This arrangement applies to bar-type connection to transformer only.<br />

3. Transformer supplier to provide necessary hardware (except nuts) for joining switchgear with transformer.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-51


Low-voltage Switchgear<br />

Type WL Low-voltage Metal-Enclosed Switchgear<br />

General<br />

Type WL Low-voltage<br />

Metal-Enclosed Switchgear<br />

14<br />

SWITCHGEAR<br />

Siemens Type WL low-voltage metalenclosed<br />

switchgear is designed,<br />

constructed and tested to provide<br />

superior power distribution, power<br />

monitoring and control. At the heart of<br />

the Type WL low-voltage switchgear is<br />

the World Class Siemens WL breaker.<br />

Siemens Type WL low-voltage<br />

switchgear can be utilized in the<br />

following applications:<br />

n Industrial<br />

Semiconductor<br />

Petrochemical<br />

Automotive<br />

Biotech<br />

Pharmaceutical<br />

n Institutional<br />

Water treatment<br />

Airports<br />

Universities<br />

Medical facilities<br />

Correctional facilities<br />

n Critical power<br />

Data Processing<br />

Continuous industrial process<br />

Hospitals<br />

n Utility and co-generation<br />

n Commercial<br />

Large office buildings<br />

Distribution centers<br />

Large warehouses<br />

Product Scope:<br />

n Equipment ratings<br />

635VAC Maximum<br />

3 Phase 3 Wire,<br />

3 Phase 4 Wire<br />

50/60 Hz<br />

6000 amp maximum horizontal bus<br />

6000 amp maximum vertical bus<br />

n Enclosure options<br />

NEMA 1 Indoor<br />

NEMA 3R Outdoor Walk-In<br />

NEMA 3R Outdoor Non Walk-in<br />

Siemens WL breakers can be manually<br />

or electrically operated, fused or<br />

unfused and are available in the<br />

following rating designations – N, S, H,<br />

L, M and F. Refer to tables on Page 13<br />

for interrupt and withstand ratings for<br />

each rating designation.<br />

Type WL Low-voltage<br />

Metal-Enclosed Switchgear<br />

Industry Standards<br />

Type WL switchgear with power circuit<br />

breakers are designed, tested and<br />

constructed in accordance with:<br />

n UL 1558 — Metal-Enclosed Lowvoltage<br />

Power Circuit Breaker<br />

Switchgear<br />

n ANSI C37.20.1 — Metal-Enclosed<br />

Low-voltage Power Circuit Breaker<br />

Switchgear<br />

n ANSI C37.50 — Test Procedure<br />

for Low-voltage AC Power Circuit<br />

Breakers Used in Enclosures<br />

n ANSI C37.51 — Conformance Testing<br />

of Metal-Enclosed Low-voltage AC<br />

Power Circuit Breaker Switchgear<br />

Assemblies<br />

n NEMA SG5 - Power Switchgear<br />

Assemblies<br />

n Applicable requirements of the<br />

National Electric Code (NEC)<br />

WL drawout circuit breakers are in<br />

accordance with:<br />

n UL 1066 — Low-voltage AC and<br />

DC Power Circuit Breakers Used in<br />

Enclosures<br />

n ANSI C37.13 — Low-voltage AC<br />

Power Circuit Breakers Used in<br />

Enclosures<br />

n ANSI C37.16 — Preferred Ratings,<br />

Related Requirements, and<br />

Application for Low-voltage Power<br />

Circuit Breakers and AC Power Circuit<br />

Protectors<br />

n ANSI C37.17 — Trip Devices for AC<br />

and General Purpose DC Low-voltage<br />

Power Circuit Breakers<br />

n NEMA SG3 - Low-voltage Power<br />

Circuit Breakers<br />

Features and modifications required<br />

by NEC are incorporated when the<br />

assembly is designated as “Service<br />

Equipment.”<br />

UL Listing<br />

Underwriters’ Laboratories listing mark<br />

(UL) is supplied for each vertical section<br />

provided all devices within a vertical<br />

section are UL Listed or UL Recognized<br />

and suitable for the intended use. All<br />

circuit breaker drawout elements are<br />

UL Listed.<br />

Optional CSA compliance with cUL<br />

labeling is available.<br />

Arc Resistant<br />

Optional Type WL arc resistant lowvoltage<br />

switchgear is available and is<br />

UL listed to ANSI/IEEE C37.20.7. Type<br />

2B arc resistant accessibility rating with<br />

maximum internal acring short-circuit<br />

current rating of 100kA @508V and<br />

85kA @ 635V.<br />

Seismic Qualification<br />

Seismic qualification to all major seismic<br />

construction standards (IBC, UBC, CBC,<br />

SBC, BOCA and IEEE 693) is available.<br />

14-52<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Low-voltage Switchgear<br />

Type WL Low-voltage Metal-Enclosed Switchgear<br />

Construction Details<br />

General<br />

The Siemens Type WL switchgear<br />

assembly consists of one or more<br />

metal-enclosed vertical sections. The<br />

end sections are designed to allow<br />

installation of future sections.<br />

Each vertical section consists of up to<br />

four individually enclosed breaker or<br />

auxiliary compartments which are sized<br />

to provide uniform height.<br />

Included in each assembly are various<br />

components such as circuit breakers,<br />

instrumentation and control equipment,<br />

transformers, relays, three-phase bus<br />

work, and all internal wiring, connectors,<br />

and other supporting equipment.<br />

In accordance with ANSI C37.20.1, the<br />

maximum temperature for parts that<br />

are handled is 50°C. The main bus<br />

maximum temperature rise is 65°C<br />

above 40°C ambient. The temperature<br />

rise of the air surrounding the cable<br />

connection points is limited to 45°C<br />

above 40°C ambient.<br />

Finish<br />

During construction, the structural steel<br />

parts, panels, and compartments are all<br />

prepared for painting by a five-stage<br />

wash system.<br />

Standard finish color is light gray ANSI<br />

61. The standard painting process is a<br />

UL approved electrostatic powder coat<br />

paint system utilizing a polyester<br />

powder coat paint. The completed finish<br />

has a nominal 2 mils dry film thickness.<br />

Assembly Construction<br />

Siemens Type WL metal-enclosed low<br />

voltage switchgear is constructed of<br />

a rigid internal frame structure that<br />

minimizes the possibility of damage<br />

during shipment and supports multiple<br />

installation methods – rolling or lifting.<br />

Lifting eyes are integrated into the<br />

internal frame design and ensure<br />

the structural integrity of the lifting<br />

assembly is always adequate for the<br />

weight of the total structure.<br />

If requested in advance, the switchgear<br />

structure can be shipped so that the<br />

unit can be tilted onto its back during<br />

installation. This is an option that must<br />

be specified at order entry.<br />

1<br />

Each complete vertical section contains<br />

three compartments.<br />

(1) Front compartment containing<br />

breakers and/or auxiliary equipment<br />

(2) Bus compartment containing<br />

horizontal and vertical bus<br />

(3) Rear cable compartment containing<br />

the load side runbacks connecting<br />

the load side of the breaker to the<br />

load cable terminals<br />

Within the front compartment, each<br />

breaker is barriered and compartmented<br />

from all other breakers in the front<br />

compartment. This design also isolates<br />

the breakers in the front compartment<br />

from the bus compartment.<br />

Optional barriers can be supplied to<br />

isolate the bus compartment from the<br />

rear cable compartment. Other optional<br />

barriers include: (1) Full depth section<br />

barriers to isolate one section from the<br />

adjacent section(s). (2) Barriers to isolate<br />

the incoming line side connections to<br />

the main breaker(s) from the load side<br />

bus and connections in the switchgear<br />

section. (Line/load barriers are provided<br />

as a standard feature for service<br />

equipment main breakers.)<br />

14 SWITCHGEAR<br />

Breaker Hoist and Track<br />

2 Ventilation and Lifting Structure<br />

2<br />

3 Quarter Turn Door Latch<br />

4 Secondary Disconnect Access Door<br />

5 Channel Sill Base (Optional)<br />

6 Breaker Compartment<br />

7 Auxiliary Instrument Compartment<br />

8 Secondary Disconnect<br />

9 Breaker Cradle (Guide Frame)<br />

Breaker Drawout Rail<br />

TOC Switch Operator<br />

7<br />

6<br />

3<br />

4<br />

8<br />

<br />

9<br />

<br />

5<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-53


Low-voltage Switchgear<br />

Type WL Low-voltage Metal-Enclosed Switchgear<br />

Construction Details<br />

14<br />

Main and Ground Bus<br />

The standard main bus is silver-plated<br />

copper. Tin-plated copper bus is<br />

optionally available. Vertical and<br />

horizontal bus bar utilize a channel<br />

shape design to maximize short circuit<br />

withstand capability and minimize heat<br />

rise. All bus joints include Grade 5 bolts<br />

and conical spring washers. Provisions<br />

for future extension of the main bus<br />

include plated joints and high tensile<br />

strength steel hardware.<br />

The main three-phase horizontal bus<br />

is arranged vertically one phase above<br />

the other with edge-to-edge alignment<br />

to provide high, short circuit strength.<br />

Insulated main bus with isolated vertical<br />

bus is optional.<br />

Control and Communication Wiring<br />

Standard control and communication<br />

wiring is #14 AWG extra-flexible,<br />

stranded copper type SIS. Control<br />

and communication wiring is installed<br />

and accessed from the front of the<br />

switchgear structure. Each breaker<br />

compartment has a dedicated horizontal<br />

and vertical wireway.<br />

For devices not having screw-type<br />

terminals, pressure terminals are used.<br />

Insulation<br />

The insulation used is a UL recognized<br />

thermoset material that has excellent heat<br />

resistance, flame retardance, dimensional<br />

stability and low moisture absorption.<br />

Circuit Breaker Compartments<br />

Typical circuit breaker compartments<br />

include primary disconnects, drawout<br />

rails, secondary disconnects, vertical<br />

wireway, horizontal wireway and,<br />

if applicable, TOC switch operator,<br />

MOC switch operator and associated<br />

interlocks. Draw-out rails allow the<br />

breaker to be withdrawn from the<br />

compartment without additional<br />

extensions or adapters. Up to six (2<br />

sets of three) current transformers for<br />

metering or relaying can be mounted<br />

in each compartment.<br />

A variety of auxiliary devices such as<br />

breaker control switches, indicating<br />

lights and pushbuttons can be mounted<br />

on the breaker compartment door.<br />

SWITCHGEAR<br />

Vertical bus ratings available are 1600,<br />

2000, 3200, 4000, 5000 and 6000<br />

amperes continuous current. Horizontal<br />

bus ratings available are 1600, 2000,<br />

3200, 4000, 5000 and 6000 amperes.<br />

A neutral bus is furnished when<br />

specified, and can be rated 1600,<br />

2000, 3200, 4000, 5000 or 6000<br />

amperes continuous current.<br />

1 2 3 4<br />

A 1/4” X 3” standard copper ground bus<br />

extends through all sections. Cable lugs<br />

are mounted to the ground bus in<br />

each section.<br />

Standard short-circuit withstand (4 cycle)<br />

and short-time withstand (60 cycle) bus<br />

bracing is 100,000 amperes. Higher<br />

shortcircuit withstand bus bracings<br />

(150kA and 200kA) are available.<br />

Load side runbacks for feeder circuits<br />

are copper construction, are insulated<br />

with sleeve tubing in the main bus area,<br />

and are supported by high-strength<br />

bus bracing.<br />

5<br />

6 7 8<br />

TOC Switch Operator<br />

2 Breaker Compartment Rear Barrier<br />

3 Secondary Disconnect<br />

4 Vertical Wireway<br />

Circuit Breaker Cell Interior<br />

5 Interference Interlock<br />

6 Drawout Rails<br />

7 Primary Disconnect<br />

8 Cradle Mounted Current<br />

Transformer<br />

14-54<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Low-voltage Switchgear<br />

Type WL Low-voltage Metal-Enclosed Switchgear<br />

Construction Details<br />

Options<br />

Switchgear Mounted Hoist<br />

The integrally mounted hoist, standard<br />

on walk-in outdoor and optional on<br />

indoor switchgear enclosures, travels<br />

along rails on top of the switchgear to<br />

assist in breaker handling.<br />

TOC and MOC Switches<br />

The Truck Operated Cell (TOC) Switch<br />

provides interlocking control or remote<br />

indication of the breaker racking<br />

position. The cubicle mounted auxiliary<br />

switch or Mechanism Operated Cell<br />

(MOC) switch provides interlocking<br />

control or remote indication based on<br />

the main contact position (open or<br />

closed).<br />

Shutters<br />

These provide protection against<br />

accidental contact with primary<br />

disconnects in a compartment when<br />

the breaker is removed. Shutters<br />

automatically close when the breaker<br />

is withdrawn and are pad-lockable and<br />

field installable.<br />

Key Interlock<br />

This provides a mechanical means<br />

for operating circuit breakers and<br />

other devices only when predescribed<br />

conditions are met.<br />

Test Set<br />

A portable breaker test set is available<br />

as an option and supports testing the<br />

full range of functions and protective<br />

settings supplied with the breaker trip<br />

unit.<br />

Metering and Auxiliary Compartments<br />

Compartments are available to house<br />

devices such as voltage transformers,<br />

metering, control power transformers,<br />

and supervisory devices.<br />

Instrument and Control Transformers<br />

Voltage transformers and control power<br />

transformers are mounted in auxiliary<br />

compartments. These transformers<br />

are protected by primary pull-out type<br />

current-limiting fuses and secondary<br />

fuses. Current transformers are<br />

normally mounted on the compartment<br />

primary disconnect studs where they<br />

are readily accessible. See Tables on<br />

Page 31 for available ratings.<br />

Miscellaneous<br />

• Each switchgear lineup includes a<br />

breaker lifting device that is adjustable<br />

for use with Size II and Size III<br />

breakers.<br />

• An optional portable breaker hoist<br />

is available if the integrated breaker<br />

hoist and track is not specified.<br />

• A test cabinet is also available as<br />

an option. The test cabinet is wall<br />

mounted necessary equipment for<br />

testing electrically-operated breakers<br />

that have been removed from the<br />

breaker compartment. The test<br />

cabinet doesn’t include or replace a<br />

breaker trip unit tester.<br />

• A WL remote breaker racking device<br />

(RBRD) is available as an optional<br />

accessory that allows maintenance<br />

personnel to safely rack Siemens<br />

Type WL breakers into the Connect,<br />

Test and Disconnect positions from<br />

up to 30 feet away from the breaker.<br />

This allows the operator to be outside<br />

the arc flash hazard boundary and<br />

thereby providing additional personnel<br />

protection.<br />

• 4” high formed steel channel sills<br />

are available for indoor switchgear<br />

enclosures.<br />

Outdoor Switchgear<br />

Type WL switchgear is available in two<br />

outdoor (NEMA 3R) enclosures. Walk-in<br />

and non walk-in versions are available<br />

to meet your particular application.<br />

For protection from snow, rain and<br />

other foreign matter, both outdoor<br />

enclosures rest on a six-inch high,<br />

formed steel base which provides rigid<br />

support and a tight bottom seal. A<br />

heavy duty protective under-coating is<br />

applied to the underside of all outdoor<br />

enclosures to protect against moisture<br />

and corrosion. Shielded ventilation<br />

housings permit proper air circulation<br />

while excluding dirt and foreign matter.<br />

In the walk-in outdoor enclosure a<br />

lighted, unobstructed service aisle is<br />

provided at the front of the switchgear<br />

allowing inspection and maintenance<br />

without exposure to the elements.<br />

An access door equipped with an<br />

emergency bar release is located at<br />

each end of the aisle.<br />

The following features are standard<br />

with walk-in outdoor enclosures.<br />

(1) Space heaters in breaker<br />

compartment and bus compartment.<br />

(2) Screens and filters for exterior door<br />

ventilation louvers.<br />

(3) Incandescent lighting receptacle<br />

with three-way switch at each aisle<br />

access door.<br />

(4) Duplex receptacle with ground fault<br />

protection at each aisle access door.<br />

(5) Load center for power distribution<br />

to lights, receptacles, switches and<br />

heaters.<br />

For non walk-in outdoor enclosures,<br />

space heaters and screens/filters for<br />

ventilation louvering are standard with<br />

lighting, receptacles, switches and load<br />

centers offered as options.<br />

Side View<br />

14 SWITCHGEAR<br />

Rear View<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-55


Low-voltage Switchgear<br />

Type WL Low-voltage Metal-Enclosed Switchgear—WL CIrcuit Breakers<br />

Overview<br />

WL Circuit Breaker<br />

Superior individual products for low-voltage power distribution systems<br />

3<br />

2<br />

4<br />

5<br />

6 7<br />

8<br />

14<br />

SWITCHGEAR<br />

21<br />

22<br />

1<br />

<br />

<br />

25<br />

<br />

9<br />

<br />

23<br />

<br />

24<br />

<br />

<br />

<br />

<br />

<br />

<br />

Guide Frame (for drawout version only)<br />

2 Vertical to Horizontal BUS Connector<br />

3 Position Signaling Switch (TOC)<br />

4 Breaker / Guide Frame Grounding<br />

Contact<br />

5 Shutter (locking)<br />

6 MODBUS or PROFIBUS<br />

Communications<br />

7 External CubicleBUS I/O Module<br />

8 Plug-In Open and Closed Solenoids<br />

9 Multiple Secondary Connections<br />

Auxiliary Switch Block<br />

Door Sealing Frame<br />

Interlocking Set Base Plate<br />

Protective Cover for<br />

OPEN/CLOSE Buttons<br />

Multiple Key Locking Accessories<br />

Single Bolt Motor Operator Installation<br />

Operations Counter<br />

Breaker Status Sensor (BSS)<br />

Complete Trip Unit Family<br />

Remote Reset<br />

Breaker Data Adapter (BDA) for<br />

Internet Connection<br />

21 Multi Angle LCD Module<br />

22 Ground Fault Protection Module<br />

23 Rating Plug<br />

24 Metering Function (+ wave forms<br />

and harmonics)<br />

25 Circuit Breaker<br />

14-56<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Low-voltage Switchgear<br />

Type WL Low-voltage Metal-Enclosed Switchgear—Electronic Trip Units<br />

Overview<br />

Electronic Trip Units<br />

During development of our electronic<br />

trip units we have consistently striven<br />

to ensure modularity. The following<br />

are just some of the modules that are<br />

simple to retrofit at any time:<br />

n Ground fault protection<br />

n Communication<br />

n Metering function<br />

n Displays<br />

n Rating plugs<br />

This enables fast local adaptation to<br />

new system conditions. At the same<br />

time, the ETUs are provided with<br />

new, innovative functions, and all trip<br />

units are completely interchangeable<br />

independent of breaker ratings.<br />

Rating Plug<br />

The Rating Plug is a replaceable module<br />

that enables users to reduce the rated<br />

device current for optimum adaptation<br />

to the system; e.g. during startup of a<br />

plant section. The Rating Plug should be<br />

selected so that it corresponds to the<br />

rated current of the system.<br />

Switch-selectable I2t or I4t<br />

Characteristic Curve Improved<br />

Overload Protection<br />

The best possible protection is assured<br />

when all protective devices in the<br />

system are optimally coordinated.<br />

To achieve optimum selectivity<br />

and coordination, the long-time<br />

characteristic can be switched between<br />

l2t and l4t.<br />

Switchable Parameter Sets<br />

To allow the protection to adapt to<br />

changes in system needs such as<br />

switching between utility and generator<br />

feeds, WL Circuit Breakers support<br />

ETUs with two independent parameter<br />

sets. Switching between the parameter<br />

sets occurs in less than 100 ms and can<br />

be done remotely or via a contact input<br />

to an optional CubicleBUS module.<br />

Extended Instantaneous Protection<br />

The electronic trip units designed<br />

for use with the WL circuit breaker<br />

provide a feature we call “Extended<br />

Instantaneous Protection” (Patent<br />

Pending).<br />

It allows the WL breaker, as a family,<br />

across the entire range of ampacities<br />

to be applied at the withstand rating of<br />

the breaker with minus 0% tolerance;<br />

that means no instantaneous override.<br />

EIP further enables the circuit breaker<br />

to be applied up to the full interrupting<br />

rating of the breaker on systems where<br />

the available fault current exceeds the<br />

withstand rating, even with LS-only trip<br />

units. Why is this feature important?<br />

The answer is reliable power.<br />

The coordination of the main breaker<br />

and the first level of feeder breakers<br />

is especially important because of the<br />

wide spread outage that will occur if<br />

one of these breakers trips<br />

unnecessarily.<br />

Conventional practice is to specify<br />

electronic trip beakers with “LS” type<br />

trip units in critical power systems.<br />

These ‘Long-Time’ and ‘Short-Time’<br />

only trip units forgo the fast tripping<br />

times given by an ‘Instantaneous’<br />

function. The justification for this delay<br />

is the benefit of allowing a downstream<br />

breaker to open first to clear a high<br />

magnitude fault. The main or feeder<br />

stays closed to keep the remainder of<br />

the loads operating.<br />

However, a circuit breaker with an<br />

LS-only trip unit may never be applied<br />

on a system capable of delivering<br />

fault current higher than the breaker’s<br />

withstand rating, commonly 85kA or<br />

less. Where the available fault current<br />

is above this level, a breaker with<br />

an additional function must be used<br />

— an instantaneous override. This<br />

instantaneous override function trips the<br />

breaker instantly when the fault current<br />

reaches a pre-determined level below<br />

the withstand rating, usually around<br />

20% lower. The benefit of this override<br />

is to allow application of the breaker up<br />

to the interrupting rating, which may be<br />

as high as 150kA. The disadvantage is<br />

that it compromises the coordination<br />

benefit because the main will probably<br />

trip at the same time as a downstream<br />

branch breaker in that 20% lower<br />

override window.<br />

This is where the Extended<br />

Instantaneous Protection feature of<br />

the WL can offer the next level of<br />

coordination and protection functionality.<br />

Unlike an instantaneous override,<br />

Extended Instantaneous Protection (EIP)<br />

allows the full withstand rating — in<br />

fact up to the tolerance of plus 20%<br />

higher. Of course, EIP still provides the<br />

ability of the breaker to be applied at the<br />

interrupting level, as high as 150kA in a<br />

Frame Size III, non-fused breaker. This<br />

unique combination enables the system<br />

designer to achieve the highest possible<br />

level of coordination in the industry and<br />

also allows application of the WL on<br />

modern power systems with extremely<br />

high levels of available fault current.<br />

A further benefit offered by EIP, over a<br />

standard LS trip unit equipped breaker,<br />

is that it provides an extra measure of<br />

protection in the event that the available<br />

fault current increases at some time<br />

during the life of the system beyond<br />

the withstand level. This would typically<br />

be due to a utility transformer change<br />

but could also be due to the addition<br />

of generators or large motors that<br />

contribute fault current. EIP provides<br />

the breaker the ability to react in an<br />

instantaneous fashion to a high level<br />

fault instead of having to rely on the<br />

slower reaction time of the short-time<br />

function.<br />

14 SWITCHGEAR<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-57


Low-voltage Switchgear<br />

Type WL Low-voltage Metal-Enclosed Switchgear—WL CIrcuit Breakers<br />

Selection<br />

Selection Criteria for WL Circuit Breakers<br />

SWITCHGEAR<br />

14<br />

The basic criteria for selecting circuit<br />

breakers is:<br />

Maximum Available Short Circuit<br />

at the installation point. This value<br />

determines the short circuit current<br />

interrupting rating or short circuit<br />

current withstand rating of the circuit<br />

breaker.<br />

Rated Current In which is to flow<br />

through the respective circuit breaker<br />

continuously. This value may not be<br />

greater than the maximum rated current<br />

of the circuit breaker. The rated current<br />

for the WL is determined by the rating<br />

plug, up to the maximum frame rating.<br />

Ambient Temperature of the circuit<br />

breaker.<br />

Design of the circuit breaker.<br />

Protective Functions of the circuit<br />

breaker.These are determined by the<br />

selection of the appropriate trip unit.<br />

Dynamic Arc-Flash Sentry (Patent<br />

Pending) A unique feature of the WL<br />

trip unit allows the system designer to<br />

achieve lower levels of arc flash energy<br />

and delayed tripping for selective trip<br />

coordination purposes.<br />

Dynamic Arc-Flash Sentry (DAS)<br />

employs the unique dual protective<br />

setting capability of the 776 trip units,<br />

coupled with the ability to easily toggle<br />

to a lower arc flash parameter set. A<br />

normal operation parameter set can be<br />

optimized for selective trip coordination,<br />

while the second set is optimized for<br />

lower arc flash energy levels. The<br />

dynamic action comes from the ability<br />

to switch from the normal operation<br />

set to the arc flash limiting set based<br />

on the presence of personnel as they<br />

approach the flash protection boundary.<br />

A wide variety of switching methods<br />

may used based on the needs of a<br />

particular facility. The capabilities range<br />

from fully automatic switching using<br />

appropriate occupancy sensors to<br />

manual switching via a key operation.<br />

14-58<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Low-voltage Switchgear<br />

Type WL Low Voltage Metal-Enclosed Switchgear<br />

Electronic Trip Unit<br />

Type WL Low-voltage Metal-Enclosed Switchgear—Electronic Trip Units<br />

Selection<br />

Electronic Trip Units<br />

Basic Protective Functions ETU745 ETU748 ETU776<br />

Long-time overcurrent protection L<br />

Short-time delayed overcurrent protection S<br />

Instantaneous overcurrent protection I --<br />

Neutral protection<br />

N<br />

Ground fault protection G <br />

14 SWITCHGEAR<br />

Additional Functions<br />

Selectable neutral protection<br />

Defeatable short-time delay<br />

Defeatable instantaneous protection --<br />

Selectable thermal memory<br />

Zone selective interlocking <br />

Selectable I 2 t or fixed short-time delay<br />

Adjustable instantaneous pick-up --<br />

Selectable I 2 t or I 4 t long-time delay<br />

Adjustable short-time delay and pick-up<br />

Selectable and adjustable neutral protection<br />

Dual protective setting capability -- --<br />

Extended instantaneous protection<br />

Parameterization and Displays<br />

Parameterization by rotary switches (10 steps) --<br />

Parameterization by communication (absolute values)<br />

Parameterization by menu/keypad (absolute values) -- --<br />

Remote parameterization of the basic functions --<br />

Remote parameterization of the additional functions -- --<br />

Alphanumeric LCD --<br />

Graphical LCD -- --<br />

Metering Function<br />

Metering function Plus <br />

Communication<br />

CubicleBUS<br />

Communication via PROFIBUS-DP <br />

Communication via the MODBUS <br />

Communication via the Ethernet (BDA) <br />

standard -- not available optional<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-59


Low-voltage Switchgear<br />

WL Low-voltage Metal-Enclosed Switchgear<br />

Technical Information<br />

Tripping Characteristics<br />

Every trip unit and every trip function<br />

has its own characteristic. You will find<br />

just a small section of these illustrated<br />

below. The characteristics show the<br />

respective greatest and smallest setting<br />

range of WL Circuit Breakers.<br />

To obtain a complete release<br />

characteristic, the appropriate<br />

characteristic functions must be<br />

determined.<br />

The characteristics show the behavior<br />

of the overcurrent release when it is<br />

activated by a current already flowing<br />

before tripping. If the overcurrent<br />

trip takes place immediately after<br />

closing and the overcurrent release is<br />

therefore not yet activated, the opening<br />

time is prolonged by about 3 to 10<br />

ms, depending on the value of the<br />

overcurrent.<br />

SWITCHGEAR<br />

14<br />

14-60<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Low-voltage Switchgear<br />

WL Low-voltage Metal-Enclosed Switchgear<br />

Technical Information<br />

Tripping Characteristics<br />

14 SWITCHGEAR<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-61


Low-voltage Switchgear<br />

WL Low-voltage Metal-Enclosed Switchgear<br />

Technical Information<br />

WL Circuit Breakers ANSI / UL 1066<br />

WL Circuit Breakers ANSI / UL 1066<br />

Breaker Ratings<br />

14<br />

SWITCHGEAR<br />

Frame Size II<br />

Frame Rating 800 1600 2000 3200<br />

Rating Class N S H L F N S H L F S H L F S H L<br />

Instantaneous Short-circuit Current 1 254VAC 50 65 85 100 200 50 65 85 100 200 65 85 100 200 65 85 100<br />

(kA RMS) 50/60 Hz 508VAC 50 65 85 100 200 50 65 85 100 200 65 85 100 200 65 85 100<br />

635VAC 50 65 65 85 200 50 65 65 85 200 65 65 85 200 65 65 85<br />

Short-time Withstand<br />

Current I cw<br />

(kA RMS) 50/60 Hz 0.5s 50 65 65 85 — 50 65 65 85 — 65 65 85 — 65 65 85<br />

Extended Instantaneous<br />

Protection<br />

(kA RMS -0% to +20%) 50 65 65 85 — 50 65 65 85 — 65 65 85 — 65 65 85<br />

Close and Latch Ratings<br />

(kA RMS) 50/60 Hz 50 65 65 85 65 50 65 65 85 65 65 65 85 65 65 65 85<br />

Rating Plug Range<br />

200, 225, 250, 300, 315, 350,<br />

400, 450, 500, 600, 630, 700,<br />

800 amps<br />

200, 225, 250, 300, 315, 350,<br />

400, 450, 500, 600, 630, 700,<br />

800, 1000, 1200, 1250,<br />

1600 amps<br />

200, 225, 250, 300, 315,<br />

350, 400, 450, 500, 600,<br />

630, 700, 800, 1000,<br />

1200, 1250, 1600,<br />

2000 amps<br />

200, 225, 250,<br />

300, 315, 350,<br />

400, 450, 500,<br />

600, 630, 700,<br />

800, 1000, 1200,<br />

1250, 1600, 2000,<br />

2500, 3000,<br />

3200 amps<br />

Endurance Rating<br />

(switching operations Mechanical 15,000 15,000 15,000 15,000<br />

with maintenance) 2 Electrical 15,000 15,000 15,000 15,000<br />

Frame Size III<br />

Frame Rating 3200 4000 5000 6000<br />

Rating Class M F H L M F H L M F H L M<br />

Instantaneous Short-circuit<br />

Current 1<br />

(kA RMS) 50/60 Hz<br />

254V AC<br />

508V AC<br />

635V AC<br />

150<br />

150<br />

85<br />

200<br />

200<br />

200<br />

85<br />

85<br />

85<br />

100<br />

100<br />

85<br />

Short-time Withstand<br />

Current Icw<br />

(kA RMS) 50/60 Hz 0.5 s 100 2 – 85 100 3 100 2 – 85 100 100 3 – 85 100 100 3<br />

Extended Instantaneous<br />

Protection<br />

(kA RMS -0% to +20%)<br />

254V AC<br />

508V AC<br />

635V AC<br />

150<br />

85 – 85 100<br />

150<br />

150<br />

85<br />

200<br />

200<br />

200<br />

85<br />

85<br />

85<br />

100<br />

100<br />

85<br />

150<br />

85 – 85 100<br />

150<br />

150<br />

85<br />

200<br />

200<br />

200<br />

85<br />

85<br />

85<br />

100<br />

100<br />

85<br />

150<br />

85 – 85 100<br />

Close and Latch Ratings<br />

(kA RMS) 50/60 Hz 100 2 85 85 85 100 2 85 85 85 100 2 85 85 85 100 2<br />

Rating Plug Range 800. 1000. 1200.<br />

1250, 1600, 2000,<br />

2500, 3000, 3200<br />

amps<br />

Endurance Rating<br />

(switching operations<br />

with maintenance) 2<br />

Mechanical<br />

Electrical<br />

10,000<br />

10,000<br />

800, 1000, 1200, 1250,<br />

1600, 2000, 2500, 3000,<br />

3200, 4000 amps<br />

10,000<br />

10,000<br />

800,1000, 1200, 1250,<br />

1600, 2000 2500, 3000,<br />

3200, 4000, 5000 amps<br />

10,000<br />

10,000<br />

150<br />

150<br />

85<br />

150<br />

85<br />

800,1000, 1200, 1250,<br />

1600, 2000 2500, 3000,<br />

3200, 4000, 5000, 6000<br />

amps<br />

10,000<br />

10,000<br />

1 Maximum rated voltage for fused breakers is 600VAC.<br />

2 Maintenance means: replacing main contacts and arc chutes (see operating instructions).<br />

3 Short-time withstand rating is 85kA RMS at 635VAC.<br />

14-62<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Low-voltage Switchgear<br />

WL Low-voltage Metal-Enclosed Switchgear<br />

Technical Information<br />

WL Non-Automatic Switches ANSI / UL 1066<br />

WL Non-Automatic Switches ANSI / UL 1066<br />

Ratings<br />

Frame Size II<br />

Frame Size III<br />

Frame Rating 800 1600 2000 3200 3200 4000 5000 6000<br />

Rating Class L F 1 L F 1 L F 1 L F 1 L F 1 L F 1 L<br />

Short-time Withstand<br />

Current<br />

(kA RMS) 50/60 Hz 0.5 s 85 20 85 20 85 20 85 40 100 40 100 40 100<br />

Breaking Capacity with<br />

External Relay (kA RMS)<br />

635Vac , 50/60 Hz,<br />

max time delay 0.5 s 85 20 85 20 85 20 85 40 100 40 100 40 100<br />

WL Circuit Breakers<br />

Frame Rating<br />

Frame Size II<br />

1 Interrupting rating is equal to 200kA based on the rating of the fuse .<br />

2 Consult factory for fuse carriage power loss .<br />

3 ETU with external control power .<br />

4 ETU without external control power .<br />

Frame Size III<br />

800 1600 2000 3200 3200 4000 5000 6000<br />

Rated current I n<br />

at 40°C, at 50/60Hz A 800 1600 2000 3200 3200 4000 5000 6000<br />

Rated operational<br />

(nominal) voltage VAC 600 600 600 600 600 600 600 600<br />

Rated maximum voltage VAC 635 635 635 635 635 635 635 635<br />

Permissible ambient<br />

temperature<br />

operation<br />

(for operation with<br />

LCD max. 55°C) °C -25 / +70 -25 / +70 -25 / +70 -25 / +70 -25 / +70 -25 / +70 -25 / +70 -25 / +70<br />

Storage<br />

(observe special<br />

conditions for LCD) °C -40 / +70 -40 / +70 -40 / +70 -40 / +70 -40 / +70 -40 / +70 -40 / +70 -40 / +70<br />

Power loss at Rated Current<br />

with 3-phase 2<br />

symmetrical load<br />

W<br />

85<br />

130<br />

(fused)<br />

320<br />

520<br />

(fused)<br />

500<br />

850<br />

(fused) 1150 700 1100 1650 2475<br />

Operating times<br />

Make-time ms 35 35 35 35 35 35 35 35<br />

Break-time (with active ETU) 3 ms 34 34 34 34 34 34 34 34<br />

Break-time<br />

(without active ETU) ms 50 50 50 50 50 50 50 50<br />

Total clearing time<br />

(with active ETU) ms 50 50 50 50 50 50 50 50<br />

Total clearing time<br />

(without active ETU) ms 65 65 65 65 65 65 65 65<br />

Make-time, electrical<br />

(via closing solenoid) ms 50 50 50 50 50 50 50 50<br />

Break-time, electrical<br />

(via shunt trip) ms 40 40 40 40 40 40 40 40<br />

(via instantaneous UVR) ms 73 73 73 73 73 73 73 73<br />

14 SWITCHGEAR<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-63


Type WL Low Voltage Metal-Enclosed Switchgear<br />

Breaker Technical Data<br />

Low-voltage Switchgear<br />

WL Low-voltage Metal-Enclosed Switchgear<br />

Technical Information<br />

14<br />

SWITCHGEAR<br />

WL Circuit Breakers<br />

WL Circuit Breakers<br />

Frame Size II<br />

Frame Size III<br />

Frame Rating 800 1600 2000 3200 3200 4000 5000 6000<br />

Endurance<br />

Mechanical<br />

(without maintenance)<br />

operating<br />

cycles 12,500 12,500 10,000 10,000 5,000 5,000 5,000 5,000<br />

Mechanical<br />

(with maintenance) 1<br />

operating<br />

cycles 15,000 15,000 15,000 15,000 10,000 10,000 10,000 10,000<br />

Electrical<br />

(without maintenance)<br />

operating<br />

cycles 7,500 7,500 4,000 4,000 2,000 2,000 2,000 2,000<br />

Electrical<br />

(with maintenance ) 1<br />

operating<br />

cycles 15,000 15,000 15,000 15,000 10,000 10,000 10,000 10,000<br />

Switching frequency 1/h 60 60 60 60 60 60 60 60<br />

Minimum interval<br />

between breaker trip and<br />

next closing of the<br />

circuit breaker (when<br />

used with the automatic<br />

mechanical reset of the<br />

bell alarm) ms 80 80 80 80 80 80 80 80<br />

Mounting position<br />

30° 30°<br />

30° 30°<br />

Dhmax.<br />

= 1 mm<br />

Auxiliary secondary wire<br />

size (Cu) max # of aux.<br />

connecting leads x cross<br />

section (solid or stranded)<br />

TOC wire connection size<br />

(Cu) max # of aux.<br />

connecting leads x cross<br />

section (solid or stranded)<br />

Weight 3<br />

Circuit Breaker<br />

Guide Frame<br />

MOC wire connection<br />

size (Cu) max # of aux.<br />

connecting leads x cross<br />

section (solid or stranded)<br />

Bare<br />

wire<br />

pressure<br />

terminal<br />

1 x AWG 14<br />

or<br />

2 x AWG 16<br />

1 x AWG 14<br />

or<br />

2 x AWG 16<br />

1 x AWG 14<br />

or<br />

2 x AWG 16<br />

1 x AWG 14<br />

or<br />

2 x AWG 16<br />

1 x AWG 14<br />

or<br />

2 x AWG 16<br />

1 x AWG 14<br />

or<br />

2 x AWG 16<br />

1 x AWG 14<br />

or<br />

2 x AWG 16<br />

1 x AWG 14<br />

or<br />

2 x AWG 16<br />

Tension<br />

spring<br />

terminal 2 x AWG 14 2 x AWG 14 2 x AWG 14 2 x AWG 14 2 x AWG 14 2 x AWG 14 2 x AWG 14 2 x AWG 14<br />

Ring tongue<br />

terminal<br />

(standard)<br />

2 x AWG 14<br />

1 x AWG 10 2<br />

2 x AWG 16<br />

2 x AWG 14<br />

1 x AWG 10 2<br />

2 x AWG 16<br />

2 x AWG 14<br />

1 x AWG 10 2<br />

2 x AWG 16<br />

2 x AWG 14<br />

1 x AWG 10 2<br />

2 x AWG 16<br />

2 x AWG 14<br />

1 x AWG 10 2<br />

2 x AWG 16<br />

2 x AWG 14<br />

1 x AWG 10 2<br />

2 x AWG 16<br />

2 x AWG 14<br />

1 x AWG 10 2<br />

2 x AWG 16<br />

2 x AWG 14<br />

1 x AWG 10 2<br />

2 x AWG 16<br />

Bare<br />

wire<br />

pressure<br />

terminal 1 x AWG 14 1 x AWG 14 1 x AWG 14 1 x AWG 14 1 x AWG 14 1 x AWG 14 1 x AWG 14 1 x AWG 14<br />

kg/lb<br />

kg/lb<br />

Bare<br />

wire<br />

pressure<br />

NSE0_00061a<br />

72/159<br />

51/112<br />

NSE0_00062a<br />

72/159<br />

51/112<br />

NSE0_00927<br />

75/165<br />

60/132<br />

95/209<br />

69/152<br />

155/341<br />

139/306<br />

155/341<br />

139/306<br />

155/341<br />

139/306<br />

155/341<br />

139/306<br />

terminal 1 x AWG 14 1 x AWG 14 1 x AWG 14 1 x AWG 14 1 x AWG 14 1 x AWG 14 1 x AWG 14 1 x AWG 14<br />

1 Maintenance consists of replacing main contacts and arc chutes (see operating instructions .)<br />

2 For use only with Siemens supplied ring terminals (WL10RL) .<br />

3 Fused Breaker Weights (kg/lb) Frame Size II (fused) Frame Size III (fused)<br />

Breaker 103/227 same as table above<br />

Guide Frame 68/150 130/275<br />

Fuse Carriage – 102/225<br />

14-64<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Type WL Low Voltage Metal-Enclosed Switchgear<br />

<br />

Low-voltage Switchgear<br />

WL Low-voltage Metal-Enclosed Switchgear<br />

Technical Information<br />

WL Circuit Breaker Accessory Ratings<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

14 SWITCHGEAR<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-65


Type WL Low Voltage Metal-Enclosed Switchgear<br />

<br />

Low-voltage Switchgear<br />

WL Low-voltage Metal-Enclosed Switchgear<br />

Technical Information<br />

WL Circuit Breaker Accessory Ratings<br />

<br />

14<br />

SWITCHGEAR<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

14-66<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Type WL Low Voltage Metal-Enclosed Switchgear<br />

<br />

Low-voltage Switchgear<br />

WL Low-voltage Metal-Enclosed Switchgear<br />

<br />

<br />

<br />

ü<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

ü<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

ü<br />

<br />

ü<br />

ü<br />

<br />

ü<br />

ü<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

ü<br />

<br />

<br />

<br />

<br />

ü<br />

<br />

<br />

<br />

<br />

ü<br />

<br />

<br />

<br />

<br />

<br />

ü<br />

<br />

<br />

ü<br />

<br />

<br />

ü<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

ü<br />

<br />

<br />

Technical Information<br />

14 SWITCHGEAR<br />

<br />

<br />

<br />

<br />

<br />

ü <br />

<br />

m <br />

<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-67


Type WL Low Voltage Metal-Enclosed Switchgear<br />

<br />

Low-voltage Switchgear<br />

WL Low-voltage Metal-Enclosed Switchgear<br />

Technical Information<br />

<br />

<br />

14<br />

SWITCHGEAR<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

m<br />

<br />

<br />

ü<br />

<br />

<br />

ü<br />

<br />

<br />

<br />

ü<br />

<br />

ü<br />

ü<br />

ü<br />

ü<br />

ü<br />

ü<br />

ü<br />

ü<br />

ü<br />

<br />

<br />

ü<br />

ü<br />

<br />

<br />

ü<br />

ü<br />

ü<br />

ü<br />

ü<br />

ü<br />

ü<br />

ü<br />

ü<br />

ü<br />

ü<br />

ü<br />

ü<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

ü <br />

<br />

m <br />

<br />

14-68<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Type WL Low Voltage Metal-Enclosed Switchgear<br />

<br />

Low-voltage Switchgear<br />

WL Low-voltage Metal-Enclosed Switchgear<br />

<br />

<br />

<br />

ü ü<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

ü ü<br />

<br />

<br />

Technical Information<br />

<br />

<br />

<br />

<br />

<br />

ü ü<br />

<br />

ü <br />

<br />

ü<br />

ü<br />

<br />

ü ü<br />

ü ü<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

ü ü<br />

<br />

<br />

<br />

<br />

ü ü<br />

<br />

<br />

<br />

<br />

ü<br />

<br />

m m <br />

ü ü<br />

<br />

<br />

ü ü<br />

<br />

<br />

ü ü<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

ü ü<br />

<br />

<br />

14 SWITCHGEAR<br />

<br />

<br />

<br />

<br />

ü <br />

<br />

m <br />

<br />

<br />

<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-69


Type WL Low Voltage Metal-Enclosed Switchgear<br />

<br />

Low-voltage Switchgear<br />

WL Low-voltage Metal-Enclosed Switchgear<br />

Technical Information<br />

<br />

14<br />

SWITCHGEAR<br />

<br />

<br />

<br />

<br />

<br />

ü<br />

<br />

<br />

<br />

<br />

<br />

m <br />

ü<br />

<br />

ü ü<br />

<br />

<br />

ü ü<br />

<br />

<br />

<br />

ü ü<br />

<br />

ü ü<br />

ü ü<br />

ü ü<br />

ü ü<br />

ü ü<br />

ü<br />

ü ü<br />

ü ü<br />

ü ü<br />

<br />

<br />

ü ü<br />

ü ü<br />

<br />

<br />

ü ü<br />

ü ü<br />

ü ü<br />

ü ü<br />

ü ü<br />

ü ü<br />

ü ü<br />

ü ü<br />

ü ü<br />

ü ü<br />

ü ü<br />

ü ü<br />

ü ü<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

ü <br />

<br />

m <br />

<br />

14-70<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Type WL Low Voltage Metal-Enclosed Switchgear<br />

Low-voltage Switchgear<br />

WL Secondary Terminal Assignments<br />

WL Low-voltage Metal-Enclosed Switchgear<br />

Technical Information<br />

WL Secondary Terminal Assignments<br />

14 SWITCHGEAR<br />

22<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-71


Low-voltage Switchgear<br />

Type WL Circuit Breakers<br />

General<br />

WL Communication Overview<br />

Connection Diagram<br />

1 Breaker Data Adapter<br />

(BDA)<br />

13 13<br />

2 Browser-capable input<br />

and output device<br />

(e.g. notebook)<br />

WinPM.Net<br />

Server<br />

WinPM.Net<br />

Web Client<br />

Ethernet /Internet /Intranet<br />

3 WL Circuit Breaker<br />

4 COM 16 MODBUS<br />

module or COM 15<br />

PROFIBUS module<br />

Ethernet<br />

14<br />

SWITCHGEAR<br />

5 Breaker Status Sensor<br />

(BSS)<br />

6 Electronic Trip Unit<br />

7 Metering function PLUS<br />

8 Zone Selective<br />

Interlocking (ZSI) module<br />

9 Digital output module<br />

with relay or optocoupler<br />

outputs<br />

10 Digital output module<br />

with relay or optocoupler<br />

outputs, remotely<br />

configurable<br />

11 Analog output module<br />

12 Digital input module<br />

MODBUS Master<br />

PLC or Supervisory<br />

Software<br />

14<br />

9510 Meter*<br />

(Ethernet<br />

Gateway)<br />

Optional<br />

2<br />

MODBUS<br />

8 9 10 11<br />

4<br />

5<br />

1<br />

6<br />

3<br />

BDA<br />

7<br />

WL Circuit Breaker<br />

with COM 16<br />

15<br />

BDA Plus*<br />

* The Siemens BDA Plus or meters, 9330, 9350, 95/9610 can<br />

be used as a gateway to enable Ethernet communication<br />

to the WL Circuit Breaker.<br />

12<br />

13 WinPM.Net on PC<br />

14 PLC (e.g. SIMATIC S7)<br />

15 BDA Plus<br />

Features<br />

n Industry standard MODBUS or<br />

PROFIBUS communication available on<br />

all WL breakers from 200A to 6000A.<br />

n The high modularity of the WL Circuit<br />

Breakers and accessories allows<br />

simple retrofitting of all communication<br />

components.<br />

n The ability to connect additional input<br />

and output modules to the breaker<br />

internal CubicleBUS of the WL opens<br />

up a range of opportunities to reduce<br />

secondary device count and wiring and<br />

to increase functionality implemented in<br />

switchgear.<br />

n Innovative software products for local<br />

configuration, operation, monitoring and<br />

diagnostics of WL Circuit Breakers using<br />

MODBUS, PROFIBUS or via Ethernet/<br />

Intranet/Internet.<br />

n Complete integration of WL Circuit<br />

Breakers in all Totally Integrated Power<br />

and Totally Integrated Automation<br />

Solutions.<br />

14-72<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


(559 m m )<br />

(559 m m Type WL Low )<br />

Voltage Metal-Enclosed Switchgear<br />

Section Configurations<br />

Low-voltage Switchgear<br />

WL Low-voltage Metal-Enclosed Switchgear<br />

Section Configurations<br />

General Notes:<br />

• A blank/instrument compartment can<br />

always be substituted for a breaker<br />

compartment.<br />

• Any 22” wide section can be 32” wide<br />

if more conduit working room is needed.<br />

• For bus duct connections – if incoming<br />

is top, Compartment A must be blank/<br />

instrument, if incoming is bottom,<br />

Compartment D must be blank/instrument.<br />

• Bussed transition section is 22” wide<br />

• For close coupled transformer connections,<br />

Compartment A must be blank/instrument.<br />

• Utility metering is always in a separate<br />

section. Section width is dependent<br />

on utility.<br />

Section Compartment Arrangement<br />

A<br />

Compartment<br />

B<br />

Compartment<br />

C<br />

Compartment<br />

D<br />

Compartment<br />

Switchgear Depth Dimensional Information<br />

(Dimensions below are for internal frames –<br />

not total structure depth)<br />

• Non-fused indoor – 60” standard, 70” and<br />

80” optional<br />

• Fused indoor – 65” standard, 75” and<br />

80” optional<br />

22 in.<br />

(559 m m )<br />

• Non-fused 22 in.<br />

non-walk-in outdoor – 60”<br />

(559 standard m m ) and 75” optional<br />

• Fused non-walk-in outdoor – 65” standard<br />

and 75” optional<br />

22 in.<br />

•(559 Non-fused m m ) 22 walk-in<br />

22 in.<br />

in. outdoor – 60” standard<br />

(559 and m m ) 75” optional<br />

(559 m m )<br />

• Fused walk-in outdoor – 65” standard and<br />

75” optional<br />

• Walk-in outdoor aisle is 42” deep<br />

• Sections with cable connected main, tie<br />

and/or feeder breakers that are 3200 amp<br />

or greater must be minimum depth of<br />

70” for unfused breakers and 75” for<br />

fused breakers.<br />

Main Sections – Non-Fused Breakers<br />

Blank or<br />

Instrument<br />

Compartment<br />

Main Breaker<br />

800, 1600,<br />

2000, 3200<br />

Feeder Breaker<br />

800, 1600,<br />

2000, 3200<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

22 in.<br />

(559 mm)<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

Feeder Breaker<br />

800, 1600,<br />

2000, 3200<br />

Main Breaker<br />

800, 1600,<br />

2000, 3200<br />

Blank or<br />

Instrument<br />

Compartment<br />

22 in.<br />

(559 mm)<br />

Blank or<br />

Instrument<br />

Compartment<br />

Blank or<br />

Instrument<br />

Compartment<br />

Main Breaker<br />

800, 1600,<br />

2000, 3200<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

22 in.<br />

(559 mm)<br />

Blank or<br />

Instrument<br />

Compartment<br />

Main Breaker<br />

4000, 5000<br />

Feeder Breaker<br />

800, 1600, 2000,<br />

3200, 4000<br />

Refer to Note 1<br />

Feeder Breaker<br />

800, 1600, 2000<br />

Refer to Note 1<br />

32 in.<br />

(813 mm)<br />

Blank or<br />

Instrument<br />

Compartment<br />

Blank or<br />

Instrument<br />

Compartment<br />

Main Breaker<br />

4000, 5000<br />

Refer to Note 3<br />

Feeder Breaker<br />

800, 1600, 2000<br />

32 in.<br />

(813 mm)<br />

Auxiliary<br />

Compartment<br />

Main Breaker<br />

6000<br />

Auxiliary<br />

Compartment<br />

32 in.<br />

(813 mm)<br />

14 SWITCHGEAR<br />

Note 1 – If a 4000 amp feeder breaker is installed in<br />

Compartment C, Compartment D must be a Blank or<br />

Instrument Compartment.<br />

Note 2 – If a 4000 amp breaker is installed in<br />

Compartment B, Compartment A must be a Blank or<br />

Instrument Compartment.<br />

Main Sections – Fused Breakers<br />

Note 3 – If incoming is bottom, feeder breakers can<br />

mount in compartments A and/or B.<br />

Note 4 – If a 3200 amp breaker is installed in<br />

Compartment B, the middle level through bus is not<br />

available.<br />

Note 5 – If a 3200 amp breaker is installed in<br />

Compartment D, the lower level through bus is not<br />

available.<br />

Note 6 – Only one 800, 1600, 2000 amp feeder breaker<br />

can be mounted per section. If the horizontal main bus<br />

is at the top of the section, the 800, 1600, 2000 amp<br />

feeder breaker can go in the A compartment and a blank/<br />

instrument compartment must go in the D<br />

compartment. If the horizontal main bus is a the bottom<br />

of the section, the 800, 1600, 2000 amp feeder breaker<br />

can go in the D compartment and a blank/instrument<br />

compartment must go in the A compartment.<br />

Blank or<br />

Instrument<br />

Compartment<br />

Main Breaker<br />

800, 1600,<br />

2000<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

22 in.<br />

(559 mm)<br />

Blank or<br />

Instrument<br />

Compartment<br />

Blank or<br />

Instrument<br />

Compartment<br />

Main Breaker<br />

800, 1600,<br />

2000<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

22 in.<br />

(559 mm)<br />

Blank or<br />

Instrument<br />

Compartment<br />

Main Breaker<br />

3200, 4000<br />

Feeder Breaker<br />

800, 1600, 2000<br />

32 in.<br />

(813 mm)<br />

Blank or<br />

Instrument<br />

Compartment<br />

Main Breaker<br />

5000<br />

32 in.<br />

(813 mm)<br />

Note 7 – Any feeder section (or bus transition section)<br />

with 6000 amp vertical bus must be 32” wide.<br />

24<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-73


Type WL Low Voltage Metal-Enclosed Switchgear<br />

Section Configurations<br />

Low-voltage Switchgear<br />

WL Low-voltage Metal-Enclosed Switchgear<br />

Section Configurations<br />

Tie Sections – Non-Fused Breakers<br />

Tie Sections – Fused Breakers<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

Feeder Breaker<br />

800, 1600, 2000<br />

Feeder 22 in.<br />

Breaker<br />

800, (559<br />

1600, m m )<br />

2000<br />

Refer to Note 2<br />

Blank 22 or Auxiliary<br />

in.<br />

Compartment<br />

(559 m m )<br />

Feeder 22 in. Breaker<br />

(559 800, m m ) 1600,<br />

2000<br />

<br />

<br />

<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

Blank or<br />

Instrument<br />

Compartment<br />

Tie Breaker<br />

800, 1600,<br />

2000, 3200<br />

Feeder Breaker<br />

800, 1600,<br />

2000, 3200<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

Tie Breaker<br />

800, 1600,<br />

2000, 3200<br />

Tie Breaker<br />

4000,<br />

5000<br />

Feeder Breaker<br />

800, 1600, 2000,<br />

3200, 4000<br />

Refer to Note 1<br />

Feeder Breaker<br />

800,<br />

Tie Breaker<br />

22 in. 1600, 2000, 22 in.<br />

22 in. 800, 1600,<br />

(559 3200, m m ) 4000<br />

22 in.<br />

22 in. (559 Main 22<br />

m<br />

in. Breaker m ) 22 in. (559 m m 2000 ) 22 in.<br />

Refer to Note 2<br />

22 in.<br />

(559 m m )<br />

(559 m m<br />

(559 ) 6000 m m )<br />

(559 m m (559 ) m m )<br />

(559 m m )<br />

Tie Breaker<br />

4000, 5000<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

<br />

<br />

<br />

<br />

<br />

<br />

Tie Breaker<br />

3200, 4000<br />

Tie Breaker<br />

5000<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

Feeder Breaker<br />

800, 1600, 2000<br />

Refer to Note 1<br />

Feeder Breaker<br />

800, 1600, 2000<br />

Blank or Auxiliary<br />

Compartment<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

<br />

<br />

<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

22 in.<br />

(559 mm)<br />

22 in.<br />

(559 mm)<br />

32 in.<br />

(813 mm)<br />

32 in.<br />

(813 mm)<br />

32 in.<br />

(813 mm)<br />

22 in.<br />

(559 mm)<br />

<br />

<br />

32 in.<br />

(813 mm)<br />

32 in.<br />

(813 mm)<br />

14<br />

SWITCHGEAR<br />

Main and Tie Sections – Non-Fused Breakers<br />

Blank or<br />

Instrument<br />

Compartment<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

Blank or<br />

Instrument<br />

Compartment<br />

Blank or<br />

Instrument<br />

Compartment<br />

Feeder Breaker<br />

800, 1600, 2000<br />

Main and Tie Sections – Fused Breakers<br />

Blank or<br />

Instrument<br />

Compartment<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

Main Breaker<br />

800, 1600,<br />

2000, 3200<br />

Tie Breaker<br />

800, 1600,<br />

2000, 3200<br />

Main Breaker<br />

800, 1600,<br />

2000, 3200<br />

Main Breaker<br />

4000, 5000<br />

Tie Breaker<br />

4000<br />

Main Breaker<br />

800, 1600,<br />

2000<br />

Main Breaker<br />

800, 1600,<br />

2000<br />

Tie Breaker<br />

800, 1600,<br />

2000<br />

Tie Breaker<br />

800, 1600,<br />

2000, 3200<br />

Main Breaker<br />

800, 1600,<br />

2000, 3200<br />

Tie Breaker<br />

800, 1600,<br />

2000, 3200<br />

Feeder Breaker<br />

800, 1600, 2000,<br />

3200, 4000<br />

Refer to Note 1<br />

Main Breaker<br />

4000<br />

Tie Breaker<br />

800, 1600,<br />

2000<br />

Tie Breaker<br />

800, 1600,<br />

2000<br />

Main Breaker<br />

800, 1600,<br />

2000<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

Feeder Breaker<br />

800, 1600, 2000<br />

Refer to Note 1<br />

Feeder Breaker<br />

800, 1600, 2000<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

22 in.<br />

(559 mm)<br />

22 in.<br />

(559 mm)<br />

22 in.<br />

(559 mm)<br />

32 in.<br />

(813 mm)<br />

32 in.<br />

(813 mm)<br />

22 in.<br />

(559 mm)<br />

22 in.<br />

(559 mm)<br />

22 in.<br />

(559 mm)<br />

Feeder Sections – Non-Fused Breakers (see Note 7 on page 24)<br />

Feeder Sections – Fused Breakers (see Note 7 on page 24)<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

Blank or<br />

Instrument<br />

Compartment<br />

<br />

<br />

<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

Refer to Note 6<br />

Blank or<br />

Instrument<br />

Compartment<br />

Feeder Breaker<br />

800, 1600,<br />

2000, 3200<br />

Feeder Breaker<br />

800, 1600,<br />

2000, 3200<br />

Refer to Note 4<br />

Feeder Breaker<br />

800, 1600,<br />

2000, 3200<br />

Refer to Note 5<br />

22 in.<br />

(559 mm)<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

Feeder Breaker<br />

4000, 5000<br />

Blank or<br />

Instrument<br />

Compartment<br />

32 in.<br />

(813 mm)<br />

Feeder Breaker<br />

4000, 5000<br />

Feeder Breaker<br />

4000, 5000<br />

Blank or<br />

Instrument<br />

Compartment<br />

32 in.<br />

(813 mm)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Feeder Breaker<br />

3200, 4000<br />

Feeder Breaker<br />

800, 1600,<br />

2000<br />

Refer to Note 6<br />

32 in.<br />

(813 mm)<br />

Feeder Breaker<br />

5000<br />

32 in.<br />

(813 mm)<br />

25<br />

14-74<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Type WL Low Voltage Metal-Enclosed Switchgear<br />

Shipping Weights and Dimensional Information<br />

Low-voltage Switchgear<br />

WL Low-voltage Metal-Enclosed Switchgear<br />

Shipping Weights and Dimensional Information<br />

Siemens Type WL Low Voltage Switchgear<br />

can be configured in many ways by<br />

combining different section types. Up<br />

to five vertical sections plus a transition<br />

section can be shipped together as a unit.<br />

Maximum shipping split length for indoor<br />

structures is 110 in. (2794 mm). If all<br />

vertical sections are not to be shipped as<br />

a unit, specifications need to be provided<br />

that describe the limiting factors (e.g.,<br />

low door or narrow hallway).<br />

Normal indoor vertical sections are 96 in.<br />

(2438 mm) high and a minimum 60 in.<br />

(1524 mm) deep for non-fused breakers<br />

and 65 in. (1651 mm) deep for fused<br />

breakers. A top-mounted hoist, which<br />

is shipped as an accessory in a separate<br />

container, adds 6.2 in. (157 mm) for a<br />

total installed height of 102.2 in.<br />

(2596 mm).<br />

The outdoor switchgear assembly<br />

contains the indoor assembly in an<br />

outdoor housing. The overall height is<br />

112.8 in. (2865 mm) for non walk-in<br />

designs and 114 in. (2896 mm) for<br />

walk-in designs. The depth of a<br />

non walk-in outdoor<br />

assembly with a 60 in. (1524 mm) internal<br />

structure is 82.3 in. (2090 mm) and the<br />

depth of a walk-in outdoor assembly with<br />

a 60 in. (1524 mm) internal structure is<br />

110.7 in. (2812 mm). Maximum shipping<br />

split length for outdoor structures is 66 in.<br />

(1676 mm).<br />

The major assembly sections include:<br />

• Transition Sections — used as<br />

transition to liquid filled transformer<br />

or to outdoor dry type transformers.<br />

• Auxiliary Sections — used as incoming<br />

bus duct or cable entrance when a<br />

main breaker is not used.<br />

• Main Sections — used to contain main<br />

breaker and may house metering and<br />

feeder breakers.<br />

• Feeder Sections — used to contain<br />

feeder breakers and other equipment<br />

such as instrumentation.<br />

• Tie Sections — used to contain tie<br />

breaker and other equipment such<br />

as feeder breakers.<br />

Transition Section For Liquid Filled and<br />

Outdoor Dry Type Transformers<br />

Dimension A Weight<br />

in inches (mm) in lbs. (kg)<br />

Indoor 55 (1397) 500 (227)<br />

Outdoor 61 (1549) 550 (250)<br />

14 SWITCHGEAR<br />

Approximate Weight – Lbs.<br />

Section Type 22” 22” 32” 32” 38” 38” 48” 48”<br />

Indoor Outdoor Indoor Outdoor Indoor Outdoor Indoor Outdoor<br />

Auxiliary<br />

1000 2000 1300 2500 1800 3200 N/A N/A<br />

(450) (900) (585) (1125) (810) (1440)<br />

Utility N/A N/A N/A N/A 2100 3500 2600 4500<br />

Metering (945) (1575) (1170) (2025)<br />

Breaker<br />

1400 2400 2000 3300 N/A N/A N/A N/A<br />

(630) (1080) (900) (1485)<br />

Weights shown in pounds and ( ) kilograms.<br />

Weights shown do not include weight of circuit breaker removeable element (but does include cradle).<br />

Add 400 lbs for hoist and track.<br />

On outdoor switchgear, add 500 lbs for end walls (weight is for both ends). Refer to shipping documents for actual weights.<br />

26<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-75


Type WL Low Voltage Metal-Enclosed Switchgear<br />

Dimensional Information<br />

Low-voltage Switchgear<br />

WL Low-voltage Metal-Enclosed Switchgear<br />

Dimensional Information<br />

Indoor Floor Plan and Cable Space Details<br />

1.25<br />

(32)<br />

typ.<br />

.86<br />

(22)<br />

4.42 (112)<br />

.75 (19) typ.<br />

.75 (19) typ.<br />

1.50<br />

(38)<br />

.86<br />

(22)<br />

5.86<br />

(149) 7.88 1<br />

(200)<br />

Note<br />

3<br />

4.82<br />

(122)<br />

B<br />

Transformer<br />

Throat<br />

4.00<br />

(102)<br />

14<br />

SWITCHGEAR<br />

A<br />

Liquid filled &<br />

outdoor dry type<br />

transformers only<br />

C L<br />

14.9<br />

(378)<br />

Maximum available<br />

space in top or bottom<br />

of unit for customer's<br />

power cables<br />

(4) Holes for<br />

.50 (12mm)<br />

Grade 5<br />

anchor bolts<br />

Space for<br />

secondary<br />

leads from<br />

above<br />

2.00 (51)<br />

5.00<br />

(127)<br />

4.00 2<br />

(102)<br />

1.00<br />

(25)<br />

2.12<br />

(54)<br />

End Trim Panel (typ.)<br />

Required on left and<br />

right end of switchboard<br />

lineup — adds 2”<br />

to total lineup width<br />

3.00 (76)<br />

D<br />

Space for<br />

secondary<br />

leads from<br />

below<br />

7.00<br />

(179)<br />

C<br />

2.37 (60)<br />

Note 4<br />

1.00 (25) W<br />

W = 22 (559) or 32 (813)<br />

1.00 (25)<br />

2.00 (51)<br />

4.40 (112)<br />

A B C D<br />

Equipment Depth<br />

Direction of Cables<br />

60” Non-Fused with<br />

1 2<br />

(N, S, H or L-Class Breakers) Below 21.50 (546)<br />

13.88 (353) 32.59 (828)<br />

OR<br />

Above 21.25 (540) 1 18.88 (480) 37.59 (955)<br />

65” Fused with (F-Class Breakers)<br />

70” Non-fused with<br />

(N, S, H or L-Class Breakers)<br />

Below 31.50 (800) 1 2 13.88 (353) 32.59 (828)<br />

OR<br />

75” Fused with (F-Class Breakers) Above 31.25 (794) 1 18.88 (480) 37.59 (955)<br />

80” Non-fused with Below 41.50 (1054) 1 2<br />

(N, S, H or L-Class Breakers) Above 41.25 (1048) 1<br />

13.88 (353) 32.59 (828)<br />

80” Fused with Below 36.50 (927) 1 2<br />

(F-Class Breakers) Above 36.25 (921) 1<br />

18.88 (480) 37.59 (955)<br />

Note: Dimensions shown in inches and (mm).<br />

1 Reduce by 7.88” if upper neutral is present with cables above or if a lower neutral is present with cables below.<br />

2 Reduce by 4.00” if an 800-3200A breaker is located in the bottom compartment.<br />

Reductions per notes 1 & 2 are additive. Example: cables below + lower neutral + 2000A breaker in bottom compartment = B-11.88.<br />

3 Reduce cable space by 4.00” x 4.82” if Neutral Riser is present. (Consult Factory).<br />

4 4.10 (104) if W=22; 4.60 (117) if W=32.<br />

27<br />

14-76<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Type WL Low Voltage Metal-Enclosed Switchgear<br />

Dimensional Information<br />

Low-voltage Switchgear<br />

WL Low-voltage Metal-Enclosed Switchgear<br />

Dimensional Information<br />

Indoor Side View<br />

Optional Hoist<br />

Lifting Holes (3)<br />

Vent stack<br />

4.0 (102)<br />

24.9<br />

(632)<br />

hoist<br />

Extension<br />

102.2<br />

(2596)<br />

top of<br />

Hoist<br />

Front<br />

Compartment<br />

E<br />

Bus<br />

Compartment<br />

17.8<br />

(452)<br />

Cable<br />

Compartment<br />

F<br />

92.0<br />

(2337)<br />

14 SWITCHGEAR<br />

42.0 (1067)<br />

Minimum<br />

Aisle Space<br />

Recommended<br />

Floor Line<br />

2.37<br />

(60)<br />

A<br />

G<br />

A E F G<br />

Equipment Depth Breaker Compartment Depth Rear Compartment Depth Anchor Bolt Spacing<br />

60 (1524) Non-fused breakers 19.8 (503) 22.4 (569) 59.13 (1502)<br />

65 (1651) Fused breakers 24.8 (630) 22.4 (569) 64.13 (1629)<br />

70 (1778) Non-fused breakers 19.8 (503) 32.4 (823) 69.13 (1756)<br />

75 (1905) Fused breakers 24.8 (630) 32.4 (823) 74.13 (1883)<br />

80 (2032) Non-fused breakers 19.8 (503) 42.4 (1077) 79.13 (2010)<br />

80 (2032) Fused breakers 24.8 (630) 37.4 (950) 79.13 (2010)<br />

Note: Dimensions shown in inches and (mm).<br />

28<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-77


Type WL Low Voltage Metal-Enclosed Switchgear<br />

Dimensional Information<br />

Low-voltage Switchgear<br />

WL Low-voltage Metal-Enclosed Switchgear<br />

Dimensional Information<br />

Outdoor Non-Walk-in Floor Plan<br />

3<br />

1<br />

2<br />

14<br />

SWITCHGEAR<br />

1 60” is representative for a 60” deep switchgear internal structure. For other<br />

internal structure depths (65 or 75) add extra depth to 60” that is shown.<br />

2 75.37 is representative for a 60” deep internal structure. For other internal<br />

structure depths (65 or 75) add extra depth to 75.37 that is shown.<br />

3 Refer to appropriate indoor plan view for available customer conduit information.<br />

Outdoor Non Walk-in Side View<br />

Dimensions shown in inches (mm)<br />

1 82.27 dimension is based on 60” internal frame structure and if a deeper<br />

internal frame structure is used (65 or 75) the extra depth should be added<br />

to the 82.27 dimension.<br />

2 75.37 dimension is based on 60” internal frame structure and if a deeper<br />

internal frame structure is used (65 or 75) the extra depth should be added<br />

to the 75.37 dimension.<br />

3 60.43 dimension is based on 60” internal frame structure and if a deeper<br />

internal frame structure is used (65 or 75) the extra depth should be added<br />

to the 60.43 dimension.<br />

4 73.77 dimension is based on 60” internal frame structure and if a deeper<br />

internal frame structure is used (65 or 75) the extra depth should be added<br />

to the 73.77 dimension.<br />

29<br />

14-78<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Type WL Low Voltage Metal-Enclosed Switchgear<br />

Dimensional Information<br />

Low-voltage Switchgear<br />

WL Low-voltage Metal-Enclosed Switchgear<br />

Dimensional Information<br />

Outdoor Walk-in Floor Plan<br />

3<br />

2<br />

1<br />

1 60” is representative for a 60” deep switchgear internal structure. For other<br />

internal structure depths (65 or 75) add extra depth to 60” that is shown.<br />

2 103.8” is representative for a 60” deep internal structure. For other internal<br />

structure depths (65 or 75) add extra depth to 103.8” that is shown.<br />

3 Refer to appropriate indoor plan view for available customer conduit information.<br />

14 SWITCHGEAR<br />

Outdoor Walk-in Side View<br />

Dimensions shown in inches (mm)<br />

1 110.7 dimension is based on 60” internal frame structure and if a deeper<br />

internal frame structure is used (65 or 75) the extra depth should be added<br />

to the 110.7 dimension.<br />

2 103.8 dimension is based on 60” internal frame structure and if a deeper<br />

internal frame structure is used (65 or 75) the extra depth should be added<br />

to the 103.8 dimension.<br />

30<br />

3 60.43 dimension is based on 60” internal frame structure and if a deeper<br />

internal frame structure is used (65 or 75) the extra depth should be added<br />

to the 60.43 dimension.<br />

4 102.2 dimension is based on 60” internal frame structure and if a deeper<br />

internal frame structure is used (65 or 75) the extra depth should be added<br />

to the 102.2 dimension.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-79


Type WL Low Voltage Metal-Enclosed Switchgear<br />

VT, CPT, CT Data<br />

Low-voltage Switchgear<br />

WL Low-voltage Metal-Enclosed Switchgear<br />

VT, CPT, CT Data<br />

Voltage Transformers – External Metering and Relaying<br />

Accuracy Class at 60 Hz<br />

Thermal<br />

Burden Volt-Amp Rating<br />

Ratio W X Y Rating VA Hertz<br />

600:120 0.6 1.2 1.2 100 150 50/60<br />

480:120 0.6 1.2 1.2 100 150 50/60<br />

288:120 0.6 1.2 1.2 100 150 50/60<br />

Control Power Transformers – 115ºC Rise<br />

14<br />

Primary<br />

Secondary<br />

kVA Phase Voltage Voltage<br />

3<br />

5<br />

10 1<br />

Single 240/480 120/240<br />

15 1 Accuracy at 60 Hz Metering Burden (ohms)<br />

SWITCHGEAR<br />

Current Transformers for FSII WL Breaker Applications - External Metering and Relaying 2<br />

Accuracy at 60 Hz Metering Burden (ohms)<br />

Ratio B-0.1 B-0.2 B-0.5 B-0.9 B-1.8 Class<br />

100.5 1.2 — — — — C5<br />

150.5 1.2 — — — — C7<br />

200.5 1.2 — — — — C9<br />

250.5 1.2 — — — — C12<br />

300.5 0.6 0.6 — — — C15<br />

400.5 0.6 0.6 1.2 — — C20<br />

500.5 0.6 0.6 1.2 — — C25<br />

600.5 0.3 0.3 0.6 1.2 1.2 C21<br />

800.5 0.3 0.3 0.6 0.6 1.2 C29<br />

1000.5 0.3 0.3 0.6 0.6 1.2 C35<br />

1200.5 0.3 0.3 0.3 0.6 0.6 C20<br />

1500.5 0.3 0.3 0.3 0.3 0.6 C25<br />

1600.5 0.3 0.3 0.3 0.3 0.6 C27<br />

2000.5 0.3 0.3 0.3 0.3 0.3 C34<br />

2500.5 0.3 0.3 0.3 0.3 0.3 C20<br />

3000.5 0.3 0.3 0.3 0.3 0.3 C21<br />

3200.5 0.3 0.3 0.3 0.3 0.3 C20<br />

Current Transformers for FSIII WL Breaker Applications – External Metering and Relaying 2<br />

Ratio B-0.1 B-0.2 B-0.5 B-0.9 B-1.8 Class<br />

2000.5 0.3 0.3 0.3 0.3 0.3 C20<br />

2500.5 0.3 0.3 0.3 0.3 0.3 C20<br />

3000.5 0.3 0.3 0.3 0.3 0.3 C20<br />

3200.5 0.3 0.3 0.3 0.3 0.3 C20<br />

4000.5 0.3 0.3 0.3 0.3 0.3 C20<br />

5000.5 0.3 0.3 0.3 0.3 0.3 C20<br />

6000.5 0.3 0.3 0.3 0.3 0.3 C20<br />

1 Requires complete compartment.<br />

2 Breaker compartment will accept 1 set of CT’s each on top and bottom primary disconnects.<br />

31<br />

14-80<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Switchboard Monitoring<br />

Sm@rtGear Mobile App<br />

Take control of your gear<br />

from your smart device<br />

Remotely monitor, configure, and control using<br />

mobile phone or tablet (wireless or hardwired)<br />

Arc flash safety<br />

n Remotely open/close breakers from outside arc<br />

flash hazard zone – no longer need dedicated<br />

control panel<br />

n Remotely activate breaker maintenance mode<br />

from outside arc flash hazard zone<br />

n Remotely view breaker status from outside arc<br />

flash hazard zone<br />

Switchgear<br />

Revised on 06/30/19<br />

Switchboard<br />

Selection<br />

Ease of commissioning<br />

n Set breaker settings via touchscreen using mobile<br />

phone or tablet<br />

Security<br />

n Local security enabled WPA2 WIFI network only<br />

allowing local access<br />

14 SWITCHGEAR<br />

MindSphere (IoT) capable<br />

Intelligence and control at your fingertips<br />

Elevation Screen WL Breaker Dashboard PAC 4200 Dashboard<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-81


Switchboard Monitoring<br />

Sm@rtGear Mobile App<br />

Revised on 06/30/19<br />

Selection<br />

Sm@rtGear Mobile Network Topology<br />

Wireless<br />

Mobile Devices Running Siemens Sm@rt Mobile App<br />

Hardwire<br />

Mobile Devices Running Siemens Sm@rt Mobile App<br />

— Ethernet<br />

— ULP<br />

14<br />

SWITCHGEAR<br />

Smart<br />

DAS<br />

Local<br />

Server<br />

Network<br />

Switch<br />

Smart<br />

DAS<br />

Local<br />

Server<br />

Network<br />

Switch<br />

Wireless<br />

Router<br />

Modbus<br />

Gateway<br />

Modbus<br />

Gateway<br />

WL/VL Electronic Trip Unit<br />

ETU<br />

Power Meter<br />

SEM3 Modular<br />

Metering<br />

WL/VL Electronic Trip Unit<br />

ETU<br />

Power Meter<br />

SEM3 Modular<br />

Metering<br />

Sm@rtGear Mobile Standard Features<br />

n Available in Type WL LV Switchgear, SB Switchboards and<br />

P4/P5 Power Panelboard<br />

n Integrates with Siemens application using phone or tablet<br />

n Ethernet switch and WIFI access point with WPA2 encryption<br />

Power/Insulated Case Circuit Breaker Feature<br />

n ETU 776 with Sm@rt Dynamic Arc Sentry (DAS)<br />

n MODBUS communication<br />

n Protective settings and alarm functions<br />

n Current and voltage monitoring<br />

n Power metering functions<br />

n Electrically operated breakers<br />

n Remote open/close<br />

Molded Case Circuit Breaker Features<br />

n ETU 586 with Smart DAS<br />

n MODBUS communication<br />

n Protective settings and alarm functions<br />

n Current monitoring<br />

n Breaker status<br />

Sm@rtGear Mobile Optional Features<br />

n PAC Digital meter integration<br />

n SEM3 submetering integration<br />

n Siemens MindSphere IoT integration<br />

14-82<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Low-voltage Switchgear<br />

Siemens Sm@rtGear Low-voltage Switchgear<br />

Introduction<br />

Sm@rtGear LVS System Architecture<br />

14 SWITCHGEAR<br />

The future<br />

The past<br />

Why settle for partial control when you can have<br />

total control and pay less? Traditional hard wired<br />

remote control panels provide additional safety<br />

for your personnel but Siemens Sm@rtGear<br />

LVS can provide the same breaker remote<br />

control plus remote monitoring and configuration<br />

of all embedded intelligent devices.<br />

Siemens Sm@rtGear LVS is pre-configured<br />

and pre-programmed low-voltage metalenclosed<br />

switchgear that provides out-of-the-box<br />

remote monitoring, configuration and control of<br />

embedded intelligent devices.<br />

All of the Sm@rtGear LVS communication<br />

backbone is installed and tested at the Siemens<br />

factory and the user only has to physically connect<br />

the three communication cables that connect the<br />

low-voltage switchgear to the remotely mounted<br />

touch screen interface panel (HMI).<br />

The remote HMI allows the user to access the<br />

intelligent devices embedded in the low-voltage<br />

switchgear. Using the HMI, the user can monitor,<br />

configure and control the intelligent devices. The<br />

Sm@rtGear LVS CPU acts as the local master<br />

and can also be a remote slave tied into an<br />

upstream supervisory system.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-83


Low-voltage Switchgear<br />

Siemens Sm@rtGear Low-voltage Switchgear<br />

Features<br />

SWITCHGEAR<br />

14<br />

Sm@rtGear LVS standard<br />

features<br />

n PC with pre-programmed software<br />

to remotely monitor, configure and<br />

control embedded intelligent devices<br />

and structural monitoring devices.<br />

n 22” touch screen HMI pre-configured<br />

and programmed with application<br />

specific graphical user interface<br />

(application specific elevation and<br />

one-line drawings) that act as user<br />

home page.<br />

n Communication backbone linking<br />

embedded intelligent devices, CPU<br />

and HMI.<br />

n ETU776 trip units in all breakers with<br />

Dynamic Arc Flash Sentry (DAS) that<br />

supports arc flash incident energy<br />

reduction.<br />

n Electrically operated breakers with<br />

spring charge motor, shunt trip and<br />

remote closing coil.<br />

n Metering and protective relaying<br />

functionality in all breakers.<br />

Sm@rtGear LVS standard<br />

functionality includes:<br />

n LVS one-line view<br />

n LVS elevation view<br />

n User Administrator<br />

n Cell Blocking<br />

n WL breaker control (Password or<br />

hardware enabled/disabled)<br />

n WL breaker monitoring<br />

n WL breaker configuration<br />

Documentation<br />

Sm@rtGear LVS optional<br />

functionality includes:<br />

n WL breaker monitoring<br />

n Digital meter monitoring (provided at<br />

no additional cost if digital meter is<br />

supplied)<br />

n TPS 6 SPD monitoring<br />

(provided at no additional cost if SPD<br />

is supplied)<br />

n High Resistance Grounding (HRG)<br />

(provided at no additional cost if HRG<br />

is supplied)<br />

n LVS structural monitoring<br />

n Custom Maintenance Reports<br />

14-84<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Low-voltage Switchgear<br />

Type WL Low-voltage Switchgear for Marine and Offshore Applications<br />

General Information<br />

Siemens Type WL Low-voltage Switchgear for<br />

Marine and Offshore Applications<br />

Siemens offers low-voltage switchgear<br />

for marine and offshore applications.<br />

Siemens Type WL Low-voltage<br />

Switchgear can be manufactured to<br />

meet ABS, USCG, DNV and Lloyd’s<br />

of London standards. Additionally<br />

all Siemens Type WL Low-voltage<br />

Switchgear is built to the applicable UL,<br />

ANSI and IEEE standards.<br />

Equipment Ratings<br />

n 635V AC maximum<br />

n 3 phase 3 wire, 3 phase 4 wire<br />

n 50/60 Hz<br />

n 6000 amp maximum horizontal bus<br />

n 6000 amp maximum vertical bus<br />

n Silver plated copper bus standard – tin<br />

plated copper optional<br />

n Standard bus bracing 100kA –optional<br />

up to 200kA<br />

Seismic Qualification<br />

Seismic qualification to all major seismic<br />

construction standards (IBC, UBC, CBC,<br />

SBC, BOCA and IEEE 693) is available.<br />

For additional Type WL low-voltage<br />

switchgear product information,<br />

including configuration information,<br />

refer to the WL Low-voltage Metal-<br />

Enclosed Switchgear Selection and<br />

Application Guide – Siemens Document<br />

No. LVSA-LVMES-0313.<br />

Additional Industry Standards<br />

Compliance<br />

Type WL switchgear with power circuit<br />

breakers are designed, tested and<br />

constructed in accordance with:<br />

n UL 1558 — Metal-Enclosed Lowvoltage<br />

Power Circuit Breaker<br />

Switchgear<br />

n ANSI C37.20.1 — Metal-Enclosed<br />

Low-voltage Power Circuit Breaker<br />

Switchgear<br />

n ANSI C37.50 — Test Procedure<br />

for Low-voltage AC Power Circuit<br />

Breakers Used in Enclosures<br />

n ANSI C37.51 — Conformance Testing<br />

of Metal-Enclosed Low-voltage AC<br />

Power Circuit Breaker Switchgear<br />

Assemblies<br />

n NEMA SG5 — Power Switchgear<br />

Assemblies<br />

n NEC — Applicable requirements of<br />

the National Electric Code (NEC)<br />

n CSA — Optional CSA compliance<br />

with cUL labeling is available.<br />

n ANSI C37.20.7 — Optional Type WL<br />

arc resistant low-voltage switchgear<br />

is available and is UL listed to ANSI/<br />

IEEE C37.20.7. Type 2B arc resistant<br />

accessibility rating with maximum<br />

internal arcing short-circuit current<br />

rating of 100kA @508V and 85kA @<br />

635V<br />

WL Drawout Circuit Breakers are in<br />

accordance with:<br />

n UL 1066 — Low-voltage AC and<br />

DC Power Circuit Breakers Used in<br />

Enclosures<br />

n ANSI C37.13 — Low-voltage AC<br />

Power Circuit Breakers Used in<br />

Enclosures<br />

n ANSI C37.16 — Preferred Ratings,<br />

Related Requirements, and<br />

Application for Low-voltage Power<br />

Circuit Breakers and AC Power Circuit<br />

Protectors<br />

n ANSI C37.17 — Trip Devices for AC<br />

and General Purpose DC Low-voltage<br />

Power Circuit Breakers<br />

n NEMA SG3 — Low-voltage Power<br />

Circuit Breakers<br />

14 SWITCHGEAR<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-85


Low-voltage Switchgear<br />

Type WL Arc Resistant Low-voltage Metal-Enclosed Switchgear<br />

General Information<br />

14<br />

SWITCHGEAR<br />

WL Arc Resistant Low-voltage Switchgear<br />

Features, Benefits and Ratings<br />

Enhanced Safety<br />

Siemens now offers arc resistant,<br />

metal-enclosed, low-voltage switchgear<br />

designed to provide an additional<br />

degree of protection for personnel<br />

performing normal operating duties in<br />

proximity to the energized equipment.<br />

Such duties include opening or closing<br />

circuit breakers, closed door circuit<br />

breaker racking, reading instruments,<br />

or other activities that do not require<br />

cover removal or opening doors (other<br />

than auxiliary/ instrument compartment<br />

doors).<br />

Why Arc Resistant Switchgear<br />

Standard metal-enclosed switchgear is<br />

designed to withstand the mechanical<br />

forces generated by bolted faults on<br />

the load terminals until a power circuit<br />

breaker or other protective device can<br />

interrupt the flow of fault current. This<br />

capability is verified by short-circuit<br />

and short-time withstand tests on the<br />

equipment and interruption tests on the<br />

power circuit breakers. During a bolted<br />

fault, the voltage at the fault location<br />

is essentially zero and the fault energy<br />

is dissipated throughout the power<br />

system. The arc generated within the<br />

power circuit breaker during interruption<br />

is cooled and extinguished by the circuit<br />

breaker arc chutes. The minimal out<br />

gassing of arc byproducts from the arc<br />

chutes is contained by the switchgear<br />

as verified by interruption tests.<br />

Siemens arc resistant low-voltage<br />

switchgear provides an added degree<br />

of protection over standard metalenclosed<br />

switchgear. In addition to<br />

bolted faults, Siemens WL arc resistant<br />

low-voltage switchgear is designed<br />

and performance tested to ANSI/IEEE<br />

C37.20.7 to provide protection from<br />

the hazards of internal arcing faults.<br />

An internal arcing fault can be caused<br />

by insulation degradation, insulation<br />

contamination, entrance of vermin,<br />

foreign objects coming into contact<br />

with the energized bus, or any other<br />

unplanned condition that creates an<br />

electrical discharge path through air.<br />

During an arcing fault, the voltage at<br />

the fault location is essentially the<br />

system voltage and the fault energy<br />

is focused within the switchgear<br />

enclosure. Arc temperatures can<br />

exceed 20,000 degrees Kelvin, rapidly<br />

heating the air and vaporizing metal<br />

parts. The expanding plasma creates<br />

severe mechanical and thermal stress<br />

in the equipment which can blow open<br />

doors and covers and burn through or<br />

fragment the enclosure.<br />

Standard Features<br />

n ANSI/IEEE Type 2B Arc Resistant to<br />

protect personnel at the front, back<br />

and sides of the equipment.<br />

n UL Listed, performance tested<br />

and classified as arc resistant in<br />

accordance with ANSI/IEEE C37.20.7.<br />

n Reinforced enclosure to withstand<br />

pressure from internal arcing faults.<br />

n Internal venting system with pressure<br />

dams and pressure vents to channel<br />

the flow of arc fault gases and vent<br />

these gases out the top of the gear<br />

and away from personnel.<br />

n Reinforced and gasketed front doors<br />

with additional hinges and latching<br />

means.<br />

n One piece circuit breaker<br />

compartment doors with insert panels<br />

for control devices such as fuses,<br />

indicating lights and circuit breaker<br />

control switches when required.<br />

n Reinforced bolted rear covers.<br />

n Insulated/Isolated bus bar system.<br />

n Integrally designed circuit breaker<br />

door sealing frame that allows the<br />

user to rack a circuit breaker to<br />

connect, test or disconnect position<br />

without having to install additional<br />

hardware (bellows, shrouds, etc) and<br />

still maintain arc resistant rating of the<br />

apparatus.<br />

n Shutters in circuit breaker<br />

compartments.<br />

n Riser Base with integrated arc<br />

plenum.<br />

n Four high power circuit breaker<br />

stacking capability. No additional<br />

stacking/configuration restrictions.<br />

n All section configurations available.<br />

Available in solidly grounded or<br />

resistance grounded configurations.<br />

n Non-fused non current-limiting<br />

circuit breakers allow full power<br />

coordination.<br />

Recommended Optional Features<br />

Overhead plenum with exhaust duct.<br />

The system is designed to transfer the<br />

byproducts of the arcing event (smoke,<br />

particulate matter, heat, etc.) away<br />

from the immediate vicinity of the lowvoltage<br />

switchgear when an internal<br />

arcing fault occurs. Typically, the<br />

14-86<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Low-voltage Switchgear<br />

Type WL Arc Resistant Low-voltage Metal-Enclosed Switchgear<br />

Dimensional Data<br />

exhaust duct will vent the byproducts<br />

to a location usually outside of the room<br />

in which the low-voltage switchgear<br />

is located. The overhead plenum is<br />

attached to the roof of the low-voltage<br />

switchgear, and can be exhausted<br />

in any direction ((left, right, forward,<br />

backward) away from the switchgear<br />

assembly or unit substation.<br />

Dynamic Arc Flash Sentry (DAS).<br />

DAS employs the unique dual<br />

parameter setting capability of the<br />

ETU776 trip unit, coupled with the<br />

ability to easily toggle to a lower arc<br />

flash parameter set. A normal operation<br />

parameter set can be optimized for<br />

selective trip coordination, while the<br />

second set is optimized for lower arc<br />

flash energy levels. The dynamic action<br />

comes from the ability to switch from<br />

the normal operation set to the arc flash<br />

limiting set based on the presence of<br />

personnel as they approach the flash<br />

protection boundary.<br />

Zone Selective Interlocking (ZSI).<br />

If WL circuit breakers are arranged in<br />

several levels and minimum delays<br />

are desired, it is advisable to use the<br />

ZSI module. The circuit breakers are<br />

interconnected by these modules. In<br />

the event of a short-circuit, all circuit<br />

breakers communicate to determine<br />

and isolate the exact short-circuit<br />

location. Thus, only the closest<br />

upstream circuit breaker will be opened.<br />

The ZSI module provides the complete<br />

range of selectivity with the short delay<br />

time of tzsi = 50 ms. By shortening the<br />

delay time, the ZSI module significantly<br />

reduces arc duration, stress and<br />

damage in the event of a short-circuit in<br />

the switchgear.<br />

High resistance grounding.<br />

Reduces available fault current during<br />

ground faults thereby reducing arc<br />

energy.<br />

Ratings<br />

• ANSI/IEEE Type 2B accessibility<br />

• Maximum internal arcing short-circuit current:<br />

100kA @ 508V and 85kA @ 635V<br />

• WL power circuit breaker frames range from 800A<br />

to 6000A<br />

• 3 and 4 pole WL power circuit breakers<br />

• Maximum arcing duration: 500 msec<br />

• Vertical bus continuous current ratings to 6000A<br />

• Horizontal bus continuous current ratings to 6000A<br />

• Maximum voltage: 635V<br />

• 3 Phase 3 Wire, 3 Phase 4 Wire<br />

• 50/60 Hz<br />

A<br />

Dimensional Data<br />

G<br />

1.25 (32)<br />

(Typ.)<br />

5.11 (130)<br />

B<br />

Non-fused 32.59 (828)<br />

Fused 37.59 (955)<br />

3.27 (83)<br />

Transformer<br />

Throat<br />

C L<br />

transformers only<br />

14.9<br />

(378)<br />

(4) Holes for<br />

.50(12mm)<br />

Grade 5<br />

anchor bolts<br />

2.37(60)<br />

Note 3<br />

Rear<br />

5.20 (132) (Note 1)<br />

Maximum Space<br />

For Cables Below<br />

4.00 (101) (Note 2)<br />

Maximum Space<br />

For Cables Above<br />

Space for<br />

secondary<br />

leads from<br />

above (Note 6)<br />

Space for<br />

secondary<br />

leads from<br />

below<br />

1.00(25) W<br />

7.00<br />

(179)<br />

4.40 (179)<br />

1.00 (25)<br />

2.00 (51)<br />

Front<br />

Plan View (WL Arc Resistant Switchgear<br />

without Optional Overhead Plenum)<br />

A = Equipment Depth +2.6 (66)<br />

2.00<br />

(51)<br />

5.00<br />

(127)<br />

4.59<br />

(Typ.)<br />

(116)<br />

2.28<br />

(Typ.)<br />

(57)<br />

1.25 (51) (Typ.)<br />

2.12 (54)<br />

Anchor Bolt Spacing<br />

G = Equipment Depth – 0.88 (22)<br />

Equipment<br />

Minimum Width<br />

W<br />

3 Pole FS2 22 (559)<br />

3 Pole FS3 32 (813)<br />

4 Pole FS2 32 (813)<br />

4 Pole FS3 40 (1016)<br />

11.40<br />

(289)<br />

B1<br />

End Trim Panel (Typ.)<br />

Required on left and<br />

right end of switchgear<br />

lineup - adds 2"<br />

to total lineup width<br />

3.00 (76)<br />

Non-Fused 13.88 (353)<br />

Fused 18.88 (480)<br />

Equipment<br />

Depth<br />

118.0 (2997) Minimum Ceiling Height Required (See Note 4)<br />

106.5 (2705)<br />

Top of Hoist<br />

24.9 (632)<br />

Hoist Extension<br />

39.0 (991) Minimum<br />

Aisle Space Required<br />

42.0 (1067) Minimum<br />

Aisle Space Recommended<br />

Floor or Pad Surface<br />

Optional Hoist<br />

Enclosure Type<br />

• NEMA 1 indoor<br />

Industry Standards<br />

• UL-1558<br />

• ANSI/IEEE C37.20.1<br />

• ANSI C37.51<br />

• ANSI/IEEE C37.20.7<br />

2.37(60) G<br />

Side View<br />

Riser Base<br />

Cable Direction<br />

Below<br />

B<br />

Lifting Holes (3)<br />

Vent Stack<br />

A<br />

4.0<br />

4.0 (102)<br />

96.0<br />

(2438)<br />

36.0 (914) Minimum<br />

Aisle Space Required<br />

Cable Direction<br />

Above<br />

B1<br />

60 (1524) Non-fused 20.00 (508) a 13.68 (347)<br />

65 (1651) Fused 20.00 (508) a 13.68 (347)<br />

70 (1778) Non-fused 30.00 (762) a 23.68 (601)<br />

75 (1905) Fused 30.00 (889) a 23.68 (728)<br />

80 (2032) Non-fused 40.00 (1016) a 33.68 (855)<br />

80 (2032) Fused 35.00 (889) a 28.68 (728)<br />

a Space available for cables below is reduced by 5.20 inches when a<br />

lower neutral bus is present.<br />

14 SWITCHGEAR<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-87


Low-voltage Switchgear<br />

Type WL Arc Resistant Low-voltage Metal-Enclosed Switchgear<br />

Dimensional Data<br />

14<br />

SWITCHGEAR<br />

Dimensional Data<br />

13<br />

(330)<br />

10<br />

(254)<br />

Overhead<br />

Plenum<br />

Vents<br />

Aux/Bkr<br />

Comp<br />

Aux/Bkr<br />

Comp<br />

Aux/Bkr<br />

Comp<br />

Aux/Bkr<br />

Comp<br />

Riser Base<br />

Overhead Plenum<br />

Vents<br />

Aux/Bkr<br />

Comp<br />

Aux/Bkr<br />

Comp<br />

Aux/Bkr<br />

Comp<br />

Aux/Bkr<br />

Comp<br />

Riser Base<br />

35.0 (889)<br />

Exhaust Duct<br />

Width = 21.36 (542)<br />

External Duct<br />

Support Holes<br />

Floor or Pad Surface<br />

104.60<br />

(2656)<br />

Exhaust Duct<br />

14.50<br />

(368)<br />

To Exterior Wall<br />

23.0 (584) x<br />

15.0 (381)<br />

Wall space required<br />

at 104.0 (2641)<br />

from f oor<br />

Front View: WL Arc Resistant Switchgear with Overhead Plenum<br />

119<br />

(3022)<br />

Note: Dimensions shown in inches and (mm).<br />

Drawings are not to scale.<br />

1. Space available for cables below is reduced by 5.20 inches when a lower<br />

neutral bus is present.<br />

2. Space available for cables below is reduced by 4.00 inches if an 800-3200A<br />

circuit breaker is located in the bottom compartment. Reductions per notes<br />

1 & 2 are additive. Example: cables below + lower neutral + 2000A circuit<br />

breaker in bottom compartment = B – 9.20<br />

3. 4.10 (104) if W = 22; 4.60 (117) if W = 32, W = 40<br />

4. 118 (2997) minimum room ceiling height is required for ventilation of arc<br />

products for LV Arc resistant switchgear without overhead plenum.<br />

5. 120 (3048) minimum room ceiling height is required for LV Arc resistant<br />

switchgear with overhead plenum.<br />

6. Not applicable for Overhead plenum application. Consult Factory for<br />

guidelines for secondary leads from above solutions.<br />

7. Custom designed exhaust duct is provided when the exit is towards the<br />

front to clear the overhead hoist. Cross-sectional area of the exhaust duct<br />

remains same as shown in figure. Wall cutout required is same at 104 (2641)<br />

from floor.<br />

8. Siemens to provide weatherproof box to be installed outside the exterior<br />

wall over the exhaust duct exit.<br />

9. The area outside the exhaust duct vent needs to be kept clear of personnel<br />

and equipment due to the potential for pressurized exhaust gases being<br />

expelled in the area as a result of arc fault in the switchgear. An area of 4<br />

feet X 4 feet centered on exhaust duct vent needs to be clear at all times.<br />

10. Exhaust duct is not self supporting, recommended support every 6 linear<br />

feet minimum. The duct supports are not supplied by Siemens and must be<br />

supplied by the purchaser or the installing contractor.<br />

11. LV Arc Resistant switchgear with and without overhead plenum should be<br />

installed on a solid surface to maintain the arc ratings.<br />

Guide Form Specifications<br />

A. This section supplements Section 16435 – Low-voltage<br />

Switch gear unless otherwise noted.<br />

B. Comply with requirements of latest revision of ANSI/IEEE<br />

C37.20.7 – Guide for Testing Metal-Enclosed Switchgear<br />

Rated up to 38kV for Internal Arcing Faults.<br />

C. Arc Resistant Electrical Ratings:<br />

1. Nominal System Voltage: [600 V] [480 V] [240 V] [208 V]<br />

2. Maximum Design Voltage: [635 V] [508 V] [254 V]<br />

3. Accessibility Type: 2B<br />

4. Internal Arcing Short-Circuit Current: [85kA @ 635V]<br />

[100 kA@ 508V]<br />

5. Arcing Duration: 100 msec, 500 msec<br />

D. Arc Resistant General Construction:<br />

1. Indoor NEMA 1 enclosure<br />

2. Riser Base with arc plenum<br />

3. Insulated/Isolated bus bar system<br />

4. [Removable rear panels with captive screws.] [Hinged<br />

rear doors with captive hardware.]<br />

5. Devices connected to the primary bus such as: surge<br />

arresters, potential transformers, control power<br />

transformers and their associated current limiting fuses<br />

must be locatedin the rear of the switchgear in the bus/<br />

cable compartment and not in auxiliary compartments.<br />

6. Shutters in power circuit breaker compartments.<br />

7. One piece circuit breaker compartment doors with insert<br />

panels for fuses, indicating lights and control switches<br />

when required.<br />

WARNING: This equipment contains hazardous voltages.<br />

Death, serious personal injury, or property damage may result<br />

if safety instructions are not followed. Only qualified personnel<br />

should work on or around this equipment after becoming<br />

thoroughly familiar with all warnings, safety notices, and<br />

maintenance procedures provided with the equipment. The<br />

successful and safe operation of this equipment is dependent<br />

upon proper handling, installation, operation and maintenance.<br />

14-88<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Low-voltage Switchgear<br />

Arc Flash Solutions<br />

General<br />

Arc Resistant Switchgear<br />

n Insulated and isolated bus<br />

n Separation barriers and top venting<br />

n Breaker shutters<br />

Arc resistant metal-enclosed low-voltage switchgear is an<br />

optional product offering that contains and channels internal<br />

arcing fault energy. This new switchgear construction provides<br />

an additional degree of protection to the personnel performing<br />

normal operating duties in close proximity to the equipment<br />

while the equipment is operating under normal conditions. In<br />

each of the descriptions below, additional design features are<br />

indicated, all of which aid in directing faults upward away from<br />

personnel or reduce the chances of a fault by insulating and<br />

isolating live parts.<br />

Front view<br />

Door gaskets and sealing trims<br />

Type 2B accessibility rating<br />

allows auxiliary/control<br />

compartment door to be open<br />

and still maintain arc resistant<br />

rating<br />

14 SWITCHGEAR<br />

Extra hinges<br />

Thumb screw latches added<br />

One piece breaker door<br />

Enhanced sill channel with<br />

internal plenum for arc venting<br />

Breaker sealing frame<br />

maintains arc resistant rating<br />

with breaker in Connect, Test<br />

or Disconnect position.<br />

Rear view<br />

Pressure release vent in rear top cover<br />

Extra bolts and pressure dams in rear<br />

covers/doors<br />

Rear vent covers extended for vent flaps<br />

Extra bolts on<br />

end trim sheets<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-89


PANEL 1<br />

SWGR 1<br />

DLA: 1600<br />

Man.: SIEMENS<br />

Trip: ETU 776 LSIG<br />

Max A/Plug/Setting: 800 / 800<br />

DLA: 1600<br />

Man.: SIEMENS<br />

Trip: ETU 776 LSIG<br />

Max A/Plug/Setting: 1600 / 1600<br />

PANEL 1<br />

SWGR 1<br />

DLA: 1600<br />

Man.: SIEMENS<br />

Trip: ETU 776 LSIG<br />

Max A/Plug/Setting: 800 / 800<br />

DLA: 1600<br />

Man.: SIEMENS<br />

Trip: ETU 776 LSIG<br />

Max A/Plug/Setting: 1600 / 1600<br />

Low-voltage Switchgear<br />

Arc Flash Solutions<br />

GRID<br />

General<br />

Dynamic Arc Sentry<br />

One of the trip units available for the Siemens WL Family of<br />

GEN 1<br />

BUS 2<br />

BUS 3<br />

breakers is the ETU 776. It offers dual parameter sets that Vs:480 V<br />

enable the trip unit to automatically lower the instantaneous<br />

setting and thereby lower the available energy in a fault<br />

condition. Commonly referred to as “maintenance mode”,<br />

making a breaker trip faster while engaged in any form<br />

of maintenance or just by being in proximity to energized<br />

TX-4<br />

GRID<br />

BUS 1<br />

TX-4<br />

GEN 1<br />

equipment is an effective way to minimize arc flash dangers.<br />

BUS 2<br />

BUS 3<br />

Vs:480 V<br />

If one is concerned about the effects of temporarily inhibiting<br />

selectivity, then rest assured that with the ETU 776 single<br />

step changes are possible giving engineers the ability to clear<br />

faults faster with minimum effect on coordination. In the<br />

example below the effects of the DAS system may be seen.<br />

BUS 1<br />

Example 1<br />

SWGR 1<br />

PPE: 3<br />

AHE: 10.6 cal/cm^2(100%)<br />

AFB: 105.68 in<br />

WD: 24 in<br />

1600<br />

WL 1600<br />

SWGR 1<br />

PPE: 0<br />

AHE: 0.74 cal/cm^2(100%)<br />

AFB: 17.38 in<br />

WD: 24 in<br />

1600<br />

WL 1600<br />

800 800 800<br />

600 600 600 800 800 800<br />

WL WL WL WL WL WL<br />

800 800 800<br />

600 600 600 800 800 800<br />

WL WL WL WL WL WL<br />

14<br />

SWITCHGEAR<br />

.01 .1 1 Time in Seconds 10 100 1000<br />

Type: WLL<br />

Size: WLL 800A<br />

PANEL 1<br />

Type: WLL<br />

Size: WLL 1600A<br />

SWGR 1 Main<br />

SIEMENS WLL ETU 776 LSIG<br />

WLL 1600A 1600 Amp<br />

PANEL 2 PANEL 3 POWER PANEL 1 POWER PANEL 2 POWER PANEL 3<br />

SWGR 1 800A FEEDER<br />

SIEMENS WLL ETU 776 LSIG<br />

WLL 800A 800 Amp<br />

.5 1 10 100 1000 10000<br />

Current in Amperes X 100<br />

.01 .1 1 Time in Seconds 10 100 1000<br />

Type: WLL<br />

Size: WLL 800A<br />

PANEL 1<br />

Type: WLL<br />

Size: WLL 1600A<br />

SWGR 1 Main<br />

SIEMENS WLL ETU 776 LSIG<br />

WLL 1600A 1600 Amp<br />

PANEL 2 PANEL 3 POWER PANEL 1 POWER PANEL 2 POWER PANEL 3<br />

SWGR 1 800A FEEDER<br />

SIEMENS WLL ETU 776 LSIG<br />

WLL 800A 800 Amp<br />

.5 1 10 100 1000 10000<br />

Current in Amperes X 100<br />

480 Volt Phase Time-Current Characteristic Curves<br />

02-15-2010<br />

TCC 1<br />

14:00:27<br />

Parameter Set A<br />

C:\EDSA2005\Projects\DAS SWGR whitepaper.PDC<br />

480 Volt Phase Time-Current Characteristic Curves<br />

02-15-2010<br />

TCC 2<br />

13:48:48<br />

Parameter Set B<br />

C:\EDSA2005\Projects\DAS SWGR whitepaper.PDC<br />

Parameter set "A"<br />

Parameter set "B"<br />

WL Breaker with ETU 776<br />

Dual Parameter<br />

sets enable<br />

“maintenance<br />

mode” - can be<br />

set remotely via<br />

software or<br />

automatically via<br />

digital input.<br />

14-90<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Low-voltage Switchgear<br />

Arc Flash Solutions<br />

General<br />

Under normal conditions, the switchgear’s calculated arc flash<br />

energy will require PPE level 3 protection for anyone within<br />

the arc flash boundary. Incorporating the features built into<br />

the DAS system, and using the ETU776 trip unit, the system<br />

changes to parameter set B. In the second figure the<br />

instantaneous has been changed to a lower setting and the<br />

calculation shows a reduction of arc flash energy. The<br />

resultant PPE level has been reduced to 0.<br />

Below is another example of the benefit of the DAS, or even<br />

manual switching, of breaker parameter set. The reduced<br />

settings set available in the ETU 776 can also be used to<br />

reduce the arc flash energy at downstream equipment. In the<br />

first figure on the left with normal settings the arc energy at<br />

panel 1 requires PPE level 2. After switching to the parameter<br />

B settings, the PPE level at Panel 1 is reduced to 0.<br />

Example 2<br />

SWGR 1<br />

WL 1600<br />

1600<br />

WL 800<br />

800<br />

PANEL 1<br />

PPE: 2<br />

AHE: 5.9 cal/cm^2(85%)<br />

AFB: 47.36 in<br />

WD: 17.9 in<br />

14 SWITCHGEAR<br />

Arc Flash in parameter A<br />

Arc Flash in parameter A<br />

Arc Flash in parameter B<br />

.01 .1 1 Time in Seconds 10 100 1000<br />

SWGR 1<br />

DLA: 1600<br />

Man.: SIEMENS<br />

Type: WLL<br />

Size: WLL 800A<br />

Trip: ETU 776 LSIG<br />

Max A/Plug/Setting: 800 / 800<br />

PANEL 1<br />

DLA: 1600<br />

Man.: SIEMENS<br />

Type: WLL<br />

Size: WLL 1600A<br />

Trip: ETU 776 LSIG<br />

Max A/Plug/Setting: 1600 / 1600<br />

.5 1 10 100 1000 10000<br />

Current in Amperes X 100<br />

480 Volt Phase Time-Current Characteristic Curves<br />

TCC 1<br />

SWGR 1 Main<br />

SIEMENS WLL ETU 776 LSIG<br />

WLL 1600A 1600 Amp<br />

800A FEEDER<br />

SIEMENS WLL ETU 776 LSIG<br />

WLL 800A 800 Amp<br />

03-31-2010<br />

11:42:04<br />

.01 .1 1 Time in Seconds 10 100 1000<br />

SWGR 1<br />

DLA: 1600<br />

Man.: SIEMENS<br />

Type: WLL<br />

Size: WLL 800A<br />

Trip: ETU 776 LSIG<br />

Max A/Plug/Setting: 800 / 800<br />

PANEL 1<br />

DLA: 1600<br />

Man.: SIEMENS<br />

Type: WLL<br />

Size: WLL 1600A<br />

Trip: ETU 776 LSIG<br />

Max A/Plug/Setting: 1600 / 1600<br />

.5 1 10 100 1000 10000<br />

Current in Amperes X 100<br />

480 Volt Phase Time-Current Characteristic Curves<br />

TCC 2<br />

SWGR 1 Main<br />

SIEMENS WLL ETU 776 LSIG<br />

WLL 1600A 1600 Amp<br />

800A FEEDER<br />

SIEMENS WLL ETU 776 LSIG<br />

WLL 800A 800 Amp<br />

03-31-2010<br />

09:34:42<br />

C:\EDSA2005\Projects\SAFETYSWITCHGEARWHITEPAPER.PDC<br />

C:\EDSA2005\Projects\SAFETYSWITCHGEARWHITEPAPER.PDC<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-91


Low-voltage Switchgear<br />

Arc Flash Solutions<br />

General<br />

Remote operation and monitoring<br />

n Remote Monitoring for temperature, metering and<br />

maintenance data.<br />

n Remote Control via communications with or without<br />

interposing relays.<br />

n Remote Racking feature.<br />

n Remote Operation for opening and closing via local hand<br />

held pendant station.<br />

Remote Monitoring is an effective way to maintain separation<br />

between personnel and energized electrical equipment.<br />

With the latest equipment from Siemens, this is now<br />

easier and more cost effective than ever. Maintenance<br />

personnel and engineers can now view real-time electrical<br />

parameters, operating conditions (like temperature in the<br />

breaker and number of operations), and open and close<br />

breakers remotely. The WinPM.Net software with its Web<br />

Enabled interface allows multiple users to access only the<br />

information they are interested in from the convenience<br />

of their desks. Accountants can access cost allocation<br />

and utility billing information to enforce accountability for<br />

electrical resources and verify utility bills. Trip settings<br />

and other parameters for the LV power breakers can be<br />

modified and monitored remotely as well.<br />

In addition, WL breakers with appropriate electrical controls<br />

and communication components, can be opened and<br />

closed through communications directly or with the use of<br />

interposing relays.<br />

14<br />

SWITCHGEAR<br />

Unit sub #5 elevation<br />

Real-time data from WL<br />

breakers with remote<br />

open/close capability<br />

14-92<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Low-voltage Switchgear<br />

Arc Flash Solutions<br />

General<br />

Remote Racking Device<br />

Although it is always preferable to work on equipment<br />

that has been de-energized, in some cases it may not be<br />

practical. Siemens now offers the Remote Breaker Racking<br />

Device. This product uses an integral torque overload sensing<br />

mechanism and allows users to safely rack our WL breakers<br />

into the Connect, Test and Disconnect position from up to 30<br />

feet away.<br />

This allows the operator to be outside the arc flash boundary<br />

thereby providing additional personnel protection and reducing<br />

the PPE requirements. This system can be retrofitted to<br />

existing Siemens WL switchgear lineups.<br />

Remote Operator Pendant<br />

This hand held pendant allows a user to remotely operate<br />

(open/close) a WL breaker without being in front of the<br />

switchgear. Standard cable lengths are 30 feet with other<br />

lengths available. This pendant, along with the Remote<br />

Racking device, can be used to improve personnel safety by<br />

putting operators outside the arc flash boundary. Maintenance<br />

personnel can remotely open breakers and close breakers,<br />

without being in front of the equipment. The Remote<br />

Operator Pendant can be used in combination with the<br />

Remote Racking Device for added personnel safety.<br />

Remote Racking Device<br />

14 SWITCHGEAR<br />

Remote Operator Pendant<br />

Control port on WL Switchgear<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-93


Low-voltage Switchgear<br />

Arc Flash Solutions<br />

General<br />

Other protection options<br />

n Infrared Viewing ports<br />

n Zone Selective Interlocking<br />

n High Resistance Grounding<br />

14<br />

SWITCHGEAR<br />

Infrared Viewing Ports<br />

Infrared viewing ports allow maintenance personnel to<br />

monitor temperatures of the cable and bus connection points<br />

in the rear of the gear while it is energized and under load.<br />

Excessive temperatures can be an indication of a problem<br />

with a connection.<br />

Zone Selective Interlocking<br />

Zone Selective Interlocking eliminates any intentional time<br />

delay in the event a fault occurs between two breakers in<br />

adjacent zones. In the schematic to the right, representative<br />

time delay values are shown for the breakers in each zone.<br />

If a fault occurs on the load side of the downstream breaker,<br />

the ZSI system enables the upstream breaker’s delay and<br />

allows the downstream device more time to independently<br />

clear the fault. If the fault occurs on the line side of the<br />

downstream breaker (between two zones), the delay in the<br />

upstream breaker will not occur. This allows the fastest<br />

tripping time for faults and will reduce the amount of arc<br />

energy which may be released. The ZSI function is available<br />

for short time delays and ground fault delays.<br />

Infrared viewing ports<br />

High Resistance Grounding<br />

Research has shown that a high percentage of arc faults<br />

start as a phase to ground fault. High resistance grounding<br />

systems minimize the available phase to ground arcing<br />

current.<br />

Zone Selective Interlocking<br />

A high resistance grounding system reduces the magnitude of<br />

phase to ground faults. This will reduce the mechanical stress<br />

on equipment for the most common of faults and will reduce<br />

the magnitude of energy released.<br />

PH1 PH2 PH3<br />

PH1 PH2 NEUT<br />

3-CLF<br />

2-CLF<br />

ROD<br />

TEST<br />

RELAY<br />

PULSE<br />

RELAY<br />

RES<br />

RES<br />

TEST<br />

RELAY<br />

PULSE<br />

RELAY<br />

TEST<br />

RESISTOR<br />

RES<br />

METER<br />

RELAY<br />

RES<br />

SYSTEM<br />

SWITCH<br />

RES<br />

RES<br />

SYSTEM<br />

SWITCH<br />

AM<br />

W<br />

NORMAL<br />

TEST<br />

RESISTOR<br />

RES<br />

METER<br />

RELAY<br />

RES<br />

W<br />

NORMAL<br />

WIRE LOOP FOR<br />

PORTABLE DETECTOR<br />

R<br />

FAULT<br />

AM<br />

R<br />

FAULT<br />

G<br />

PULSE<br />

WIRE LOOP FOR PORTABLE DETECTOR<br />

G<br />

PULSE<br />

CONTROL<br />

CIRCUIT<br />

PULSE SW<br />

CONTROL<br />

CIRCUIT<br />

PULSE SW<br />

14-94<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Busway Systems<br />

SPEEDFAX TM<br />

Section<br />

Scan to connect<br />

online to the<br />

most up-todate<br />

version of<br />

this Section of<br />

SPEEDFAX.<br />

Sentron connection<br />

XJ-L<br />

Bus plugs<br />

c o n t e n t s<br />

Busway Systems Overview<br />

General Pricing Notes 15-2<br />

Busway Selector Chart 15-3<br />

Sentron ® Busway<br />

Sentron Busway Overview 15-4 – 15-5<br />

Catalog Numbering System 15-6<br />

Technical Data 15-7 – 15-8<br />

Straight Sections – Feeder, Plug-In, & One-Sided Plug-In 15-9 – 15-10<br />

Busway Straight Sections Aluminum & Copper 15-11<br />

Elbows 15-12 – 15-13<br />

Offsets and Combinations 15-14 – 15-15<br />

Tees 15-16<br />

Tap Boxes 15-17 – 15-21<br />

Expansion Fittings 15-22<br />

Reducers and Phase Rotation Fittings 15-23<br />

Service Heads 15-24<br />

Hangers and End Closers 15-25 – 15-27<br />

Roof and Wall/Ceiling/Floor Flanges 15-28<br />

Busway Accessories 15-29<br />

Flanged Ends, Combination Flange/Elbows 15-30 – 15-32<br />

Cubicle Options 15-33<br />

Panelboards and Meter Center Modules 15-34 – 15-35<br />

Installation and Application Information 15-36<br />

Sentron Busway Quick Reference 15-39<br />

Programs and Services 15-37 – 15-41<br />

Sentron Bus Plugs<br />

Bus Plug Overview 15-43<br />

Circuit Breaker Bus Plugs 15-44 – 15-49<br />

Fusible Bus Plugs 15-50 – 15-55<br />

SPD Bus Plugs 15-56 – 15-58<br />

3/6 Bus Plugs 15-59 – 15-63<br />

XJ-L TM HD Busway<br />

Introduction and Overview 15-64 – 15-65<br />

Busway Specifications 15-66<br />

Straight Sections 15-67 – 15-68<br />

Elbows, Tees and Crosses 15-69 – 15-70<br />

Tap Boxes and Flanges 15-71 – 15-73<br />

Accessories - Hangers & End Closers 15-74<br />

XJ-L HD Bus Plugs<br />

Selection Guide and Catalog Numbering System 15-75<br />

XQ and XQR Series 15-76<br />

XPM Series 15-77<br />

XEC and XLEC Series 15-78<br />

XLVB Series and Plug-in Tap Box 15-79<br />

Legacy Products<br />

BD ® Plug-In (225 - 1600 Ampere) Copper 15-80<br />

XL-U ® Aluminum (225–5000 Ampere) 15-81<br />

XL-U Copper (225–6500 Amperes) 15-82<br />

XL-X ® , XL-U, BD Plug-In Units 15-83 – 15-84<br />

15<br />

BUSWAY SYSTEMS<br />

(Section was last modified on 02/12/20)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-1


Busway Systems Overview<br />

Pricing Notes<br />

Revised on 04/30/18<br />

General<br />

15<br />

BUSWAY SYSTEMS<br />

A. Footage Pricing<br />

1. Sentron and XL-U base pricing is<br />

listed on a per foot charge. When<br />

calculating the footage charge,<br />

fractions are figured to the next<br />

larger number of whole feet (i.e.,<br />

a linear run totaling 66'3" would<br />

be priced at 67 feet.)<br />

2. BD and XJ-L HD base pricing is<br />

listed on a per section charge.<br />

B. Accessories<br />

Some busway accessories are<br />

listed as complete device prices<br />

while others are listed under<br />

accessory charges.<br />

1. Complete device price includes all<br />

material and accessory charges<br />

for a standard device. (Busway<br />

footage included if applicable).<br />

2. Accessory Charge includes<br />

fabrication and any miscellaneous<br />

fittings for the standard device.<br />

(No busway footage included).<br />

C. End Cable Tap Boxes are designed<br />

to be installed at the beginning or<br />

end of a busway run. The busway<br />

rating determines the tap box list<br />

price. Mechanical lugs are standard.<br />

For compression lugs add 30% to<br />

tap box list price.<br />

D. Elbows with an angle other than 90<br />

degrees, the accessory charge is to<br />

be doubled.<br />

E. Flange Ends (Switchboard<br />

Connections / Stubs) accessory<br />

prices are for connection to Siemens<br />

equipment. For connection to other<br />

manufacturer’s equipment, multiply<br />

the flange end list price by 2.5.<br />

Standard list price includes eight<br />

inches of bus extension into<br />

equipment from mounting flange,<br />

if more than 8 inches required<br />

consult factory for pricing. Sentron<br />

Switchboards can be assembled<br />

with the Busway Flanged End<br />

pre-installed, eliminating the labor<br />

to connect the Busway to the<br />

switchboard at the job site.<br />

F. Service Heads are specially<br />

constructed tap boxes suitable for<br />

outdoor use and are equipped to<br />

accept service cables through a<br />

removable insulated bottom plate.<br />

The busway should be priced<br />

through the end of the run.<br />

G. Phase Transpositions can be built<br />

into a busway section to provide<br />

better voltage balance on long runs.<br />

To price, use the “Expansion Section”<br />

accessory charge for the appropriate<br />

ampere rating.<br />

H. Hangers<br />

Sentron and XL-U busway are UL<br />

listed for standard hanger spacing<br />

of ten feet (on center). Purchasing<br />

busway hangers for horizontal<br />

installations is optional. Unistrut/<br />

Kindorf is commonly used by<br />

contractors as an approved<br />

alternative.<br />

Two hangers are furnished free of<br />

charge with every straight section of<br />

BD and XJ-L HD. Self compensating<br />

“Spring” hangers required for<br />

vertical installations are designed to<br />

be field installed by the installer and<br />

are shipped separately. These are<br />

also used as intermediate supports<br />

where floor-to-floor height is greater<br />

than 16 feet.<br />

I. Ceiling, Floor And Wall Flanges are<br />

used when busway passes through a<br />

floor or wall and are intended to<br />

cover that portion of the opening<br />

around the outside of the busway.<br />

They are not to be used to<br />

support the busway.<br />

J. Reducers price is determined by the<br />

rating of the larger busway. Fused<br />

reducers do not include fuses.<br />

K. Special Paint — Busway Sections,<br />

Accessories And Bus Plugs<br />

Standard finish is ASA #61 light gray.<br />

For other than standard color, add<br />

20% and consult factory for<br />

availability. XJL HD Busway is<br />

offered in ASA#61 Gray and Graphite<br />

Gray.<br />

L. For Silver Finishing of Copper Bus<br />

Bars, add 10%.<br />

M. Roof Flanges are specially constructed<br />

collars and plates built onto a section of<br />

3R busway which passes through a flat<br />

or angled roof. Roof pitch must be<br />

given for angled roof.<br />

N. Circuit Breaker Type Bus Plugs<br />

for Sentron Busways are priced as<br />

“complete devices” with circuit<br />

breakers factory installed.<br />

Circuit Breaker plugs for BD, XL-U<br />

and XL-X busways are priced<br />

“enclosure only” unless otherwise<br />

indicated. XJ-L HD may or may not<br />

have a circuit breaker and receptacle<br />

installed, depending upon the bus<br />

plug type.<br />

O. Fusible Type Bus Plugs do not<br />

include fuses. Adapter kits for Class<br />

R, T & J fuses are available for field<br />

installation.<br />

P. Cubicle list prices include labor and<br />

material for a single frame device<br />

with enclosure including line side<br />

internal bussing for connection to<br />

busway and protective device.<br />

Fuses and load side bussing are<br />

not included in the base price.<br />

Q. Sentron Busway has been tested in<br />

accordance with UL1479 and offers<br />

a certified two hour fire rating for<br />

gypsum wall board construction,<br />

and a three hour fire rating for<br />

concrete slab or block penetrations.<br />

These ratings were achieved using<br />

standard busway installed with<br />

SpecSeal ® sealant from<br />

Specified Technologies Inc.<br />

This material is available through<br />

Electrical Distribution.<br />

R. Expansion Section<br />

Qty (1) Expansion Section should be<br />

used for every 200ft of continuous<br />

Busway run length, at every<br />

transition to a vertical run, and for<br />

each building expansion joint. The<br />

Busway run must be positioned<br />

accordingly to accommodate the<br />

Expansion Section(s).<br />

15-2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Busway Systems Overview<br />

Busway Selector Chart (100-6500 Ampere)<br />

Revised on 04/30/18<br />

General<br />

I-T-E (previously known as Bulldog Electric) was<br />

the first manufacturer to make a Busway System.<br />

Since its introduction in 1932, Busway Systems have<br />

improved and expanded into several designs to meet<br />

the ever changing needs of the electrical industry.<br />

The Busway Selection Chart below will help you in<br />

selecting the proper product to fit your requirements.<br />

Busway Selector Chart<br />

100-6500 Ampere 600 Volts or Less<br />

Product<br />

Plug-in and Feeder Busway<br />

Feature<br />

Ampere<br />

Rating<br />

Conductor<br />

Use<br />

AC Service<br />

50-60 Hz<br />

400Hz <br />

Sentron<br />

Plug-in/Feeder<br />

XL-U<br />

Plug-in/Feeder<br />

XJ-L HD<br />

Plug-in<br />

BD<br />

Plug-in<br />

100 u<br />

150<br />

200<br />

225 u u u u<br />

400 u u u u<br />

600 u u u<br />

800 u u u<br />

1000 u u u<br />

1200 u u u<br />

1350 u u u<br />

1600 u u u<br />

2000 u u<br />

2500 u u<br />

3000 u u<br />

3200 u<br />

4000 u u<br />

5000 u u<br />

6000, 6500 u<br />

Copper u u u u<br />

Aluminum u u<br />

Indoor u u u u<br />

Outdoor u u<br />

2W<br />

1Ø3W<br />

u<br />

3Ø3W u u u u<br />

3Ø4W 100% N u u u u<br />

3Ø4W 200% N u u<br />

Voltage 600 volts or less u u u u<br />

Ventilated<br />

u<br />

Construction<br />

Non-Ventilated u u u u<br />

UL 857 u u u u<br />

Meets<br />

NEMA BU1 u u u u<br />

Electrical<br />

CSA/CUL C22.2 NO 27 u u u u<br />

Standard<br />

ANCE NMX-J-148ANCE u u u u<br />

15<br />

BUSWAY SYSTEMS<br />

a Consult factory for information.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-3


Sentron Busway Systems<br />

Sentron Busway Overview<br />

Revised on 04/30/18<br />

Overview<br />

15<br />

BUSWAY SYSTEMS<br />

Sentron Busway for Global Power Distribution Applications<br />

Building on a solid foundation of<br />

advanced products for the construction<br />

industry, the Siemens Sentron name is<br />

recognized worldwide as synonymous<br />

with quality and consistent performance.<br />

Sentron Busway delivers impressive<br />

features and benefits that make it<br />

ideal for many types of industrial and<br />

construction implementations.<br />

Engineered to ensure the safe and<br />

efficient distribution of power in<br />

industrial, commercial and institutional<br />

environments world-wide, Sentron<br />

ampacities range from 225A to 5000A<br />

UL. Thanks to an innovative design, you<br />

benefit from labor-saving installation and<br />

a flexible, compact bus system that is<br />

an ideal fit for most applications. In fact,<br />

Sentron Busway is one of the industry’s<br />

least labor-intensive systems.<br />

Sentron Busway installs with minimal<br />

hardware and often costs less than<br />

cable and conduit installations. The<br />

lightweight aluminum housing acts as an<br />

integral ground, joint stacks connect with<br />

splice plates featuring a single-bolt<br />

design, and bus plugs and cable tap<br />

boxes offer the industry’s largest wire<br />

bending space. An optional 200%<br />

neutral within the bus bar housing<br />

accommodates harmonics common in<br />

today’s power systems.<br />

Sentron Busway conductors are<br />

insulated with a state-of-the-art epoxy<br />

insulation system, which is applied using<br />

an electrostatic spray process for optimal<br />

insulation integrity.<br />

Exemplifying the spirit of continuing<br />

innovation, Sentron Busway is now<br />

available with economical and convenient<br />

elbow stacks for changing left, right, up<br />

or down directions at 90 degrees.<br />

And, of course, Sentron Busway is<br />

certified to design standards worldwide,<br />

including UL, NEMA, IEC, CSA, VDE<br />

and BS.<br />

Siemens Busway Business uses<br />

industry leading technology in all its<br />

manufacturing processes. From bus bar<br />

fabrication to Electrostatic Spray Epoxy<br />

insulation, all the processes used in<br />

the manufacturing of Siemens Sentron<br />

Busway are electronically controlled<br />

to provide for consistent, high quality<br />

results, making Sentron Busway<br />

products best in its class.<br />

Housing<br />

Sentron Busway incorporates an all<br />

aluminum housing. This lightweight<br />

totally enclosed, non-ventilated housing<br />

resists rust and other elements,<br />

distributes heat away from the<br />

conductors, and provides an excellent<br />

ground path. The totally enclosed<br />

design also eliminates the need for<br />

derating of the system regardless of<br />

installation orientation. The housing is<br />

covered with an electrostatically applied<br />

light gray ANSI 61 polyester urethane<br />

powder paint that is scratch resistant<br />

and has a 1,000-hour salt spray<br />

resistance rating.<br />

Conductors<br />

Sentron Busway conductors have<br />

a compact construction and can be<br />

configured as 3-phase 3-wire, 3-phase<br />

4-wire or 3-phase 4-wire with 200%<br />

neutral. The conductors may be ordered<br />

in copper (98% conductivity), 1000A/in 2<br />

M-Rated Copper, Aluminum (58%<br />

conductivity) and 750A/in 2 L-Rated<br />

Aluminum. The optional 200% neutral<br />

helps to handle harmonic conditions<br />

that may exist. This system is<br />

especially useful with discharge lighting<br />

(fluorescent) and computer installations.<br />

This will help to minimize overheating<br />

and prolong the life cycle of your power<br />

distribution equipment.<br />

Ground<br />

Sentron Busway offers ground options<br />

to meet your specifications: standard<br />

integral aluminum housing ground and<br />

optional internal grounding bars. An<br />

optional isolated ground is also available<br />

which is especially useful in applications<br />

where a clean ground is needed (such<br />

as hospitals or high tech).<br />

Plating<br />

All bus bars are electroplated with<br />

tin. This unique tin plating provides<br />

excellent conductivity and prevents<br />

impurities from attaching to the bars.<br />

Optional silver plating is also available<br />

with a copper conductor only.<br />

Insulation<br />

Sentron Busway is insulated with<br />

an Epoxy Powder Coating system<br />

designed by Siemens Engineers, Epoxy<br />

System Engineers and Epoxy Powder<br />

Specialists, specifically for Siemens<br />

Busway products.<br />

The Siemens exclusive Electrostatic<br />

Spray insulation process produces<br />

uniform application of Epoxy powder<br />

over the entire conductor bar. This is<br />

further enhanced by the inline filter<br />

process and magnetic separator<br />

that helps to eliminate contaminants<br />

common to fluidized bed systems. The<br />

electrostatic application also provides<br />

a better coating consistency than that<br />

of the older fluidized bed process. The<br />

combination of electrostatic spray and<br />

lower oven temperatures produces<br />

a consistent coverage with fewer<br />

impurities and pinholes in the insulation.<br />

The lower oven temperatures reduce<br />

the risk of bar annealing, which affects<br />

the overall quality of the system.<br />

Sentron Busway insulation is Class B,<br />

130°C Rated. Every bus bar and<br />

completed assembly is dielectric<br />

tested to ensure the insulation is free<br />

of defects.<br />

15-4<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron Busway Systems<br />

Sentron Busway Overview<br />

Revised on 04/30/18<br />

Overview<br />

Joint Stack<br />

Each Sentron Busway piece is shipped<br />

with a joint stack and joint covers<br />

installed at one end of the busway and a<br />

shipping end protector at the other end.<br />

The joint stacks feature a single bolt<br />

design and a special, torque indicating,<br />

double headed break-off bolt. This<br />

eliminates the need for torque wrenches<br />

and assures proper torque at installation<br />

of 50 ft.-lbs.(68 N-m).<br />

When the proper torque value is<br />

achieved, the top bolt head will shear<br />

off. Each joint stack allows for +/- .625<br />

inches (15.8mm) adjustability at each<br />

joint. Over adjustment is prevented by<br />

the joint covers, which will only allow a<br />

.625 inch (15.8mm) adjustment when<br />

the knockouts on the joint cover are<br />

removed.<br />

It is possible to remove any joint<br />

connection assembly to allow electrical<br />

isolation or removal of a busway length<br />

without disturbing adjacent busway<br />

lengths. Isolation joint stacks are<br />

available and used to electrically isolate<br />

a busway section(s) within a busway<br />

run. For easy visual identification,<br />

isolation joint stack assemblies are<br />

painted white.<br />

Joint Assembly<br />

Plug-in Opening<br />

Sentron Busway offers plug-in style<br />

busway which feature plug-in openings<br />

rated for finger safety to IP2X in<br />

accordance with IEC 529 and BS EN<br />

60439-1, -2 and BS EN 60529.<br />

Each plug-in opening has a reversible<br />

hinged dead front designed to protect<br />

the contact surfaces from dirt, dust or<br />

moisture. Gasketing is used where<br />

applications require a splash proof<br />

(IP55) rating.<br />

IP Ratings<br />

Sentron Busway is available in a variety<br />

of IP ratings. Use the chart below to<br />

determine the IP rating that best fits<br />

your application needs.<br />

Testing<br />

Each piece of Sentron Busway is factory<br />

tested before shipping. Tests performed<br />

include dielectric tests, which are used<br />

to insure integrity of insulation. In<br />

addition, Sentron Busway is tested in<br />

accordance with both UL and IEC<br />

standards. All Sentron Busway is<br />

manufactured and inspected in an ISO<br />

9001:2000 registered facility.<br />

Plug-In Opening<br />

and Cover<br />

Standards<br />

Watch<br />

All Sentron Busway<br />

the Joint<br />

products meet the<br />

following standards:<br />

Assembly<br />

video<br />

n UL 857<br />

n NEMA BU1<br />

n CSA C22.2<br />

n IEC 60529 (2004)<br />

n BS EN 60529<br />

n BS EN 60439-1,<br />

60439-2<br />

n UL 1479<br />

n DIN 4102 Parts 9&12<br />

n BS 6387 Parts 11.1 and 11.2<br />

Labor Savings<br />

Using Sentron Busway instead of cable<br />

and conduit can create savings of up to<br />

20 - 30% on total installed costs. Sentron<br />

busway is lightweight, compact and<br />

takes half the time to install as cable and<br />

conduit. For more information, visit our<br />

web site at www.sea.siemens.com.<br />

15<br />

BUSWAY SYSTEMS<br />

Levels of Protection Description<br />

Sentron Busway<br />

Code Description<br />

Feeder Plug-In Sentron Bus Plugs<br />

IP 2X Plug-In outlet protects against access to live parts by .472 in. (12 mm) test probe, even with cover • • •<br />

opened. Finger Safe<br />

IP 40 Enclosure protects against entry of .039 in. (1.0 mm) test probe. Indoor (Typical UL Designation) • • •<br />

IP 55 Enclosure protects against entry of dust and water jets. Splash Proof • • •<br />

IP 66 Enclosure is dust tight and protects against powerful water jets. Outdoor (International Only) •<br />

NEMA 3R Enclosure protects against rain, sleet and damage from ice formation. Outdoor •<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-5


Sentron Busway Systems<br />

Catalog Numbering System<br />

Revised on 04/30/18<br />

Selection<br />

Suffix part of Catalog Numbers<br />

15<br />

BUSWAY SYSTEMS<br />

S X 4 0 2 C 1 0<br />

Sentron<br />

SX = US Lengths<br />

Configuration<br />

3 = 3Ø, 3W<br />

4 = 3Ø, 4W 100% Neutral<br />

5 = 3Ø, 4W 200% Neutral<br />

Ampere Rating<br />

02 = 225A 32 = 3200A<br />

04 = 400A 40 = 4000A<br />

06 = 600A 50 = 5000A a<br />

08 = 800A<br />

10 = 1000A<br />

12 = 1200A<br />

13 = 1350A<br />

16 = 1600A<br />

20 = 2000A<br />

25 = 2500A<br />

30 = 3000A<br />

Bus Bar Material<br />

C = Copper<br />

M = 1000 Amps/In 2 Copper<br />

A = Aluminum<br />

L = 750 Amps/In 2 Aluminum<br />

Ground<br />

1 = Integral (Housing)<br />

2 = Internal Bus Bar b<br />

3 = Isolated Ground b<br />

IP Rating<br />

0 = IP40 f<br />

4 = IP55 f<br />

6 = IP66 cgh<br />

9 = NEMA 3R dgh<br />

a Copper only<br />

b Copper or aluminum ground bar<br />

c IEC Markets<br />

d NEMA Markets<br />

e For odd degree angle (other than 90°) specify the degree angle of the turn.<br />

f Indoor only (Plug-in and Feeder)<br />

g Outdoor use (Feeder only)<br />

h Elbow Stack (IP40 and IP55 only)<br />

Feeder Length in Inches, ex.: 2'3" = 027<br />

Feeder lengths available from 1'3"<br />

(024 Inches) up to 10'0" (120 inches)<br />

Plug-in L Length 04 = 4'0"<br />

06 = 6'0"<br />

08 = 8'0"<br />

10 = 10'0"<br />

One-sided I Length 04 = 4'0"<br />

plug-in (Riser)<br />

06 = 6'0"<br />

08 = 8'0"<br />

10 = 10'0"<br />

Elbows<br />

P L 0 6<br />

S = Stack h<br />

L = 90° Edge Up<br />

O = Odd<br />

Down<br />

degree angle e Flat Right<br />

Left<br />

Tees E Edge Up<br />

Down<br />

Flat<br />

Right<br />

Left<br />

Offsets F Edge Up<br />

Down<br />

Flat<br />

Right<br />

Left<br />

Combinations O Edge Up Flat Left<br />

Edge Down Flat Left<br />

Edge Up Flat Right<br />

Edge Down Flat Right<br />

Flat Left<br />

Flat Left<br />

Flat Right<br />

Flat Right<br />

EXpansion P F T<br />

Fittings<br />

Edge Up<br />

Edge Down<br />

Edge Up<br />

Edge Down<br />

Center Cable T B Standard<br />

Tap Boxes<br />

EXpanded<br />

End Cable T Vertical Standard<br />

Tap Boxes Horizontal EXpanded<br />

Joint Mounted T Vertical Left<br />

Tap Boxes Horizontal Right<br />

Both<br />

End Closers C L S<br />

FlanGe Roof F L<br />

Wall<br />

Joint Stacks Standard S T<br />

Isolation<br />

SerVice Heads 1 = 1-Phase Tranformer H<br />

3 = 3-Phase<br />

T = Throat Utility Florida Pwr/Light<br />

Houston Pwr/Light<br />

Commonwealth ED<br />

Pacific Gas/Electric<br />

Detroit Edison<br />

San Diego<br />

Seattle<br />

Other<br />

Reducers Fused R F<br />

Non-fused R N<br />

Flanged End E = Int’l Standard N D<br />

R = U.S. Standard N<br />

D<br />

O = Other<br />

Transposition R PG = Phase & Ground<br />

PO = Phase only<br />

GO = Ground only<br />

15-6<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron Busway Systems<br />

Technical Data<br />

Revised on 04/30/18<br />

Technical<br />

Temperature Rise Curves<br />

Aluminum Bus Bar<br />

Sentron Busway<br />

Temperature Rise Curves<br />

Copper Bus Bar<br />

Sentron Busway<br />

Amperage<br />

Amperage<br />

Temperature Rise ˚C<br />

Temperature Rise ˚C<br />

R, X, Z and Ohms, Voltage Drop<br />

Voltage Drop - Concentrated Loads, Line-to-Line per 100 feet at 100%<br />

Bus Bar Width Ohms x 10 -3 per 100 feet Rated Load, 35°C Ambient <br />

x 0.25 in. Line to Neutral Power Factor<br />

Ampere Rating (6.4mm) Thick R X Z 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0<br />

AL L-Rated c<br />

225 — 1.75 (44.5) 3.94 1.13 4.10 0.88 1.02 1.15 1.27 1.39 1.49 1.57 1.54<br />

400 — 1.75 (44.5) 4.08 1.23 4.26 1.66 1.91 2.15 2.38 2.58 2.77 2.91 2.83<br />

600 — 1.75 (44.5) 4.26 1.32 4.46 2.64 3.03 3.40 3.75 4.08 4.37 4.58 4.43<br />

800 400 2.38 (60.5) 3.42 1.06 3.58 2.82 3.24 3.64 4.02 4.36 4.67 4.90 4.74<br />

1000 600 3.25 (82.6) 2.45 0.74 2.56 2.50 2.88 3.24 3.57 3.89 4.17 4.38 4.24<br />

1200 800 4.38 (111.3) 1.86 0.59 1.95 2.32 2.66 2.99 3.29 3.58 3.82 4.01 3.87<br />

1350 1000 5.38 (138.7) 1.39 0.24 1.41 1.50 1.81 2.10 2.39 2.67 2.93 3.17 3.25<br />

1600 1200 6.50 (165.1) 1.21 0.45 1.29 2.19 2.48 2.75 3.00 3.23 3.43 3.56 3.35<br />

2000 1350,1600 8.75 (222.3) 0.91 0.35 0.98 2.11 2.38 2.64 2.87 3.08 3.26 3.37 3.16<br />

2500 2000 (2) 5.63 (143.0) 0.68 0.29 0.74 2.09 2.34 2.57 2.78 2.97 3.12 3.21 2.95<br />

3000 2500 (2) 6.75 (171.5) 0.54 0.28 0.61 2.24 2.47 2.67 2.85 3.01 3.12 3.16 2.80<br />

3200 2000 (2) 7.50 (190.5) 0.48 0.33 0.58 2.53 2.73 2.91 3.06 3.17 3.23 3.20 2.68<br />

4000 3000,3200 (2) 9.00 (228.6) 0.46 0.21 0.51 2.34 2.61 2.85 3.08 3.27 3.43 3.51 3.20<br />

CU M-Rated c<br />

225 — 1.75 (44.5) 2.34 1.13 2.60 0.69 0.77 0.84 0.90 0.95 0.99 1.01 0.91<br />

400 — 1.75 (44.5) 2.44 1.13 2.69 1.26 1.40 1.52 1.64 1.74 1.82 1.86 1.69<br />

600 — 1.75 (44.5) 2.58 1.16 2.83 1.96 2.18 2.39 2.58 2.74 2.87 2.94 2.68<br />

800 400 1.75 (44.5) 2.71 1.17 2.95 2.67 2.98 3.28 3.55 3.78 3.97 4.08 3.76<br />

1000 — 2.25 (67.2) 2.12 0.89 2.30 2.58 2.88 3.17 3.44 3.67 3.86 3.98 3.67<br />

1200 600 2.88 (73.2) 1.66 0.77 1.83 2.56 2.85 3.11 3.35 3.56 3.72 3.80 3.45<br />

1350 800 3.50 (88.9) 1.30 0.64 1.45 2.34 2.59 2.82 3.03 3.20 3.33 3.39 3.04<br />

1600 1000 4.50 (114.3) 1.06 0.56 1.20 2.37 2.60 2.82 3.01 3.17 3.29 3.32 2.94<br />

2000 1200,1350 6.00 (152.4) 0.77 0.44 0.89 2.27 2.48 2.66 2.83 2.96 3.05 3.07 2.66<br />

— 1600 — — — — — — — — — — — —<br />

2500 2000 8.50 (215.9) 0.53 0.35 0.65 2.15 2.34 2.50 2.64 2.75 2.82 2.81 2.39<br />

3000 — (2) 4.75 (120.7) 0.49 0.27 0.56 2.07 2.28 2.46 2.62 2.76 2.86 2.89 2.54<br />

3200 — (2) 5.50 (139.7) 0.44 0.30 0.53 2.33 2.51 2.67 2.80 2.90 2.96 2.93 2.44<br />

4000 2500,3000,3200 (2) 6.50 (165.1) 0.39 0.26 0.47 2.50 2.71 2.89 3.04 3.16 3.23 3.21 2.71<br />

5000 4000 (2) 8.50 (215.9) 0.30 0.21 0.37 2.49 2.69 2.86 3.00 3.11 3.17 3.15 2.63<br />

15<br />

BUSWAY SYSTEMS<br />

Notes:<br />

For plug-in distributed loads, divide voltage drop<br />

values by 2.<br />

To determine voltage drop line-to-neutral, multiply lineto-line<br />

values by 0.577.<br />

Actual voltage drop for different lengths and at<br />

loadings less than full rated current can be calculated<br />

using the formula:<br />

Vd (actual) = Vd (table) x actual load x actual length (ft)<br />

rated load 100 feet<br />

For 50 Hz, multiply reactance (X) by 0.85 and resistance<br />

values do not change. For 400 Hz, multiply reactance<br />

by 3.75 and multiply resistance by 1.4. Calculate new<br />

voltage drop:<br />

Vd = amps load x E3(Rcos θ + X sin θ) per 100 ft,<br />

where cos θ = Power Factor.<br />

For metric conversion R, X, Z values ”in Ohms per<br />

meters Line to Neutral”<br />

R x .0328<br />

X x .0328<br />

Z x .0328<br />

For metric conversion ”Line to Line per meter at 25° C<br />

ambient in mV/A/m” (Vd 32.8) / A. Divide Vd by 2 for<br />

distributed loads.<br />

Voltage Drop will decrease in lower ambient<br />

temperature. Contact Siemens for Voltage Drop in<br />

other ambient conditions.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-7


Sentron Busway Systems<br />

Technical Data<br />

Technical<br />

Ground Capacity<br />

15<br />

BUSWAY SYSTEMS<br />

Effective Current<br />

Min. CSA<br />

Carrying Capacity Grd. Circuit Characterisitics under Fault<br />

for<br />

Sectional<br />

of Housing Conditions Ohms x 10 -3 per 100 ft<br />

Bus Bar<br />

Ground Bus Area 50% Integral<br />

Width Bars per UL 857 Internal (Hsg.) % of % of Internal Ground Housing Ground<br />

Inches per Table 14 Ground Bar Ground UL Phase<br />

Ampere Rating (mm) Pole In2 (mm2) In2 (mm2) In2 (mm2) Req Bar R X Z R X Z<br />

A L-Rated<br />

225 — 1.75 (44.5) 1 0.08 (53.5) 0.22 (141.1) 2.30 (1485.1) 1333 253 4.872 9.037 10.267 5.797 12.963 14.200<br />

400 — 1.75 (44.5) 1 0.17 (107.1) 0.22 (141.1) 2.30 (1485.1) 667 253 4.872 9.037 10.267 5.797 12.963 14.200<br />

600 — 1.75 (44.5) 1 0.17 (107.1) 0.22 (141.1) 2.30 (1485.1) 667 253 4.872 9.037 10.267 5.797 12.963 14.200<br />

800 400 2.38 (60.5) 1 0.17 (107.1) 0.30 (191.9) 2.40 (1550.1) 688 192 3.351 7.333 8.063 4.932 10.000 11.150<br />

1000 600 3.25 (82.6) 1 0.20 (126.5) 0.41 (262.1) 2.54 (1639.9) 607 147 2.833 6.628 7.208 3.662 8.442 9.202<br />

1200 800 4.38 (111.1) 1 0.23 (146.5) 0.55 (352.8) 2.72 (1756.6) 552 115 2.487 5.852 6.358 3.189 6.926 7.625<br />

1350 1000 5.38 (136.5) 1 0.29 (189.7) 0.67 (433.5) 2.88 (1859.8) 446 94 2.182 5.115 5.561 2.713 5.883 6.478<br />

1600 1200 6.50 (165.1) 1 0.29 (189.7) 0.81 (524.2) 3.06 (1975.4) 467 84 1.801 4.489 4.837 2.289 5.206 5.687<br />

2000 1350,1600 8.75 (222.3) 1 0.35 (227.7) 1.09 (705.6) 3.42 (2207.7) 425 69 1.390 3.467 3.735 1.623 4.267 4.565<br />

2500 2000 5.63 (142.9) 2 0.52 (332.3) 1.41 (907.3) 3.85 (2480.7) 320 59 1.145 2.955 3.169 1.526 3.837 4.129<br />

3000 2500 6.75 (171.5) 2 0.59 (380.0) 1.69 (1088.7) 4.20 (2711.9) 301 53 0.954 2.683 2.848 1.221 3.635 3.835<br />

3200 2000 7.50 (190.5) 2 0.81 (522.6) 1.88 (1209.7) 4.44 (2866.8) 229 51 0.894 2.493 2.648 1.144 3.428 3.614<br />

4000 3000,3200 9.00 (228.6) 2 0.81 (522.6) 2.25 (1451.6) 4.92 (3176.5) 250 50 0.715 2.339 2.446 0.916 3.378 3.500<br />

CU M-Rated<br />

225 — 1.75 (44.5) 1 0.05 (33.5) 0.22 (141.1) 2.30 (1485.1) 2128 261 3.803 6.330 7.380 5.183 10.083 11.338<br />

400 — 1.75 (44.5) 1 0.11 (67.7) 0.22 (141.1) 2.30 (1485.1) 1054 261 3.803 6.330 7.380 5.183 10.083 11.338<br />

600 — 1.75 (44.5) 1 0.11 (67.7) 0.22 (141.1) 2.30 (1485.1) 1054 261 3.803 6.330 7.380 5.183 10.083 11.338<br />

800 400 1.75 (44.5) 1 0.11 (67.7) 0.22 (141.1) 2.30 (1485.1) 1054 261 3.803 6.330 7.380 5.183 10.083 11.338<br />

1000 — 2.25 (57.2) 1 0.13 (85.2) 0.28 (181.5) 2.38 (1536.7) 860 207 3.029 5.993 6.715 4.409 9.191 10.194<br />

1200 600 2.88 (73.0) 1 0.18 (114.2) 0.36 (231.9) 2.48 (1601.8) 661 166 2.460 5.676 6.186 3.674 8.212 8.996<br />

1350 800 3.50 (88.9) 1 0.24 (152.3) 0.44 (282.3) 2.58 (1665.8) 510 140 2.188 5.267 5.704 2.807 7.492 8.000<br />

1600 1000 4.50 (114.3) 1 0.24 (152.3) 0.56 (362.9) 2.74 (1769.0) 534 113 1.893 4.323 4.719 2.756 6.880 7.411<br />

2000 1200,1350 6.00 (152.4) 1 0.29 (189.7) 0.75 (483.9) 2.98 (1923.8) 457 90 1.476 3.181 3.507 2.205 6.032 6.422<br />

— 1600 6.50 (165.1) 1 0.29 (189.7) 0.81 (524.2) 3.06 (1975.4) 467 84 1.801 4.489 4.837 2.289 5.206 5.687<br />

2500 2000 8.50 (215.9) 1 0.35 (227.7) 1.06 (685.5) 3.38 (2181.9) 421 70 1.087 2.020 2.294 1.764 5.419 3.072<br />

3000 — 4.75 (120.7) 2 0.41 (265.8) 1.19 (766.1) 3.56 (2290.0) 376 66 0.984 1.874 2.117 1.470 4.631 4.859<br />

3200 — 5.50 (139.7) 2 0.59 (380.0) 1.38 (887.1) 3.80 (2453.9) 277 60 0.947 1.691 1.938 1.378 4.129 4.353<br />

4000 2500,3000,3200 6.50 (165.1) 2 0.59 (380.0) 1.63 (1048.4) 4.12 (2660.3) 296 54 0.773 1.500 1.688 1.323 3.060 3.334<br />

5000 4000 8.50 (215.9) 2 0.71 (456.1) 2.13 (1371.0) 4.76 (3073.2) 278 50 0.606 1.218 1.360 0.882 1.783 1.989<br />

Note: Bus bar thickness = .25 in. (6.4mm), Ground bar thickness = .125 in.(3.18mm)<br />

UL Short Circuit Ratings<br />

UL Series Connected with Fuse<br />

Maximum Fuse Size for 200kA<br />

RMS Symmetrical (kA)<br />

RMS Symmetrical Rating<br />

Ampere Rating 6 cycle 1 sec. 3 sec. Class R Class J & T Class L<br />

AL L-Rated<br />

225 — 85 28 16 600 600 J & T —<br />

400 — 85 28 16 600 600 J & T —<br />

600 — 85 28 16 600 600 J & T —<br />

800 400 100 47 27 — 800 T 1200<br />

1000 600 100 50 29 — — 3000<br />

1200 800 125 60 35 — — 3000<br />

1350 1000 150 75 43 — — 3000<br />

1600 1200 150 90 52 — — 3000<br />

2000 1350,1600 150 110 64 — — 5000<br />

2500 2000 200 130 75 — — 5000<br />

3000 2500 200 160 92 — — —<br />

3200 2000 200 160 92 — — —<br />

4000 3000,3200 200 200 115 — — —<br />

CU M-Rated<br />

225 — 85 40 23 600 600 J & T —<br />

400 — 85 40 23 600 600 J & T —<br />

600 — 85 40 23 600 600 J & T —<br />

800 400 85 40 23 — 800 T 1600<br />

1000 — 100 50 29 — — 3000<br />

1200 600 100 65 38 — — 3000<br />

1350 800 100 80 46 — — 3000<br />

1600 1000 125 95 55 — — 4000<br />

2000 1200,1350 150 115 66 — — 5000<br />

— 1600 150 90 52 — — 3000<br />

2500 2000 150 130 75 — — 5000<br />

3000 — 200 175 101 — — —<br />

3200 — 200 175 101 — — —<br />

4000 2500,3000,3200 200 200 115 — — —<br />

5000 4000 200 200 115 — — —<br />

Sentron Busway has UL<br />

approved Series Ratings. By<br />

using the appropriate line side<br />

fuse, short circuit ratings can be<br />

enhanced to 200kA for lower<br />

amperage busway.<br />

15-8<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron Busway Systems<br />

Straight Sections – Plug-In, One-Sided Plug-In and Feeder<br />

Revised on 04/30/18<br />

Selection<br />

Straight Sections<br />

Sentron Busway can be ordered with<br />

Aluminum or Copper bus bars.<br />

Aluminum bars are available in 225-4000<br />

ampere sections. Copper bars are<br />

available in 225-5000 ampere sections.<br />

Sentron Busway includes an integral<br />

housing ground, and is available with an<br />

internal ground bar or an isolated ground<br />

bar in all ampere ratings. Sentron<br />

Busway housing is a four-piece<br />

aluminum design.<br />

Plug-In Sections<br />

Sentron plug-in sections are designed<br />

with plug-in openings centered on 24 in.<br />

(610mm) intervals, and are located on<br />

both sides of the busway for optimum<br />

utilization. Plug-in sections are available<br />

in standard lengths of 4 ft. (1.22m), 6 ft.<br />

(1.83m), 8 ft. (2.44m) and 10 ft. (3.05m).<br />

Sentron plug-in sections meet IP40<br />

(indoor) and IP55 (splash proof)<br />

requirements. One joint stack assembly<br />

is provided with each plug-in section.<br />

One-Sided Plug-In Sections<br />

Sentron one-sided plug-in sections are<br />

designed with plug-in openings centered<br />

on 24 in. (610mm) intervals on one side<br />

of the busway only. This eliminates<br />

unusable plug-in outlets in vertical<br />

applications. One-sided plug-in busway<br />

is available in standard lengths of 4 ft.<br />

(1.22m), 6 ft. (1.83m), 8 ft. (2.44m) and<br />

10 ft. (3.05m). Sentron one-sided plugin<br />

busway is available in IP40 (indoor)<br />

and IP55 (splash proof). One joint stack<br />

assembly is provided with each section.<br />

Plug-In Outlet Features<br />

The plug-in outlet molded guard design<br />

prevents incidental finger contact with<br />

live conductors. Sentron plug-in outlets<br />

are IP 2X rated (with the outlet cover<br />

open) which means a .472 in. (12mm) or<br />

larger probe is unable to enter a plug-in<br />

outlet. The outlet is IP40 Rated with the<br />

cover closed and IP55 Rated when<br />

configured with gaskets.<br />

Feeder Sections<br />

Feeder busway carries the current of the<br />

busway system from the supply source.<br />

Feeder busway does not have plug-in<br />

outlets. Sentron Feeder busway is<br />

available in custom lengths from<br />

15 in. (0.37m) to 10 ft. (3.05m). Feeder<br />

sections are rated as IP40 (Indoor), IP55<br />

(Splash Proof), NEMA 3R (Outdoor), and<br />

IP66 (International Outdoor). One joint<br />

stack assembly is provided with each<br />

feeder section.<br />

Standard Plug-In Section (Standard plug-in outlets on both sides on 24 in. centers)<br />

Suffix PL04 (4 ft.), PL06 (6 ft.), PL08 (8 ft.), PL10 (10 ft.)<br />

15<br />

BUSWAY SYSTEMS<br />

Standard One-Sided Plug-In Section (Standard Plug-In outlets on one side on 24 in. centers)<br />

Suffix RI04 (4 ft.), RI06 (6 ft.), RI08 (8 ft.), RI10 (10 ft.)<br />

Standard Feeder Section<br />

Suffix F024 - 120 (last 3 digits = length in Inches, 015=15 in., 120=120 in.)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-9


Sentron Busway Systems<br />

Revised on 04/30/18<br />

Selection<br />

15<br />

BUSWAY SYSTEMS<br />

Sentron Busway, Widths and Weights<br />

Approximate Weight - lbs per ft. (kg per meter)<br />

3Ø, 4-Wire<br />

3Ø, 3-Wire 3Ø, 4-Wire 3Ø, 4-Wire 200% Neutral<br />

Dimension with Internal with Internal 200% with Internal<br />

Ampere Rating Inches (mm) 3Ø, 3-Wire Ground 3Ø, 4-Wire Ground Neutral Ground<br />

AL L-Rated<br />

225 — “W1” 3.9 (99) 5 (8) 5 (8) 6 (9) 6 (9) 7 (10) 7 (10)<br />

400 — “W1” 3.9 (99) 5 (8) 5 (8) 6 (9) 6 (9) 7 (10) 7 (10)<br />

600 — “W1” 3.9 (99) 5 (8) 5 (8) 6 (9) 6 (9) 7 (10) 7 (10)<br />

800 400 “W1” 4.6 (117) 6 (9) 6 (9) 7 (10) 7 (10) 7 (11) 8 (11)<br />

1000 600 “W1” 5.4 (137) 7 (10) 7 (11) 8 (12) 8 (12) 9 (13) 9 (14)<br />

1200 800 “W1” 6.6 (168) 8 (12) 9 (13) 9 (14) 10 (15) 11 (16) 11 (17)<br />

1350 1000 “W1” 7.6 (193) 9 (13) 10 (15) 11 (16) 11 (17) 12 (18) 13 (19)<br />

1600 1200 “W1” 8.7 (221) 10 (15) 11 (17) 12 (18) 13 (19) 14 (21) 15 (22)<br />

2000 1250,1600 “W1” 10.9 (277) 13 (19) 14 (21) 15 (23) 16 (24) 18 (26) 19 (28)<br />

2500 2000 “W2” 13.7 (348) 15 (22) 17 (25) 18 (27) 20 (30) 22 (33) 23 (34)<br />

3000 2500 “W2” 15.8 (402) 17 (25) 19 (28) 21 (31) 23 (34) 25 (37) 27 (40)<br />

3200 2000 “W2” 17.3 (439) 18 (27) 20 (30) 23 (34) 25 (37) 27 (40) 29 (43)<br />

4000 3000,3200 “W2” 20.3 (516) 22 (33) 25 (37) 27 (40) 30 (44) 32 (48) 35 (52)<br />

CU M-Rated<br />

225 — “W1” 3.9 (99) 9 (13) 10 (14) 10 (16) 11 (17) 12 (18) 13 (19)<br />

400 — “W1” 3.9 (99) 9 (13) 10 (14) 10 (16) 11 (17) 12 (18) 13 (19)<br />

600 — “W1” 3.9 (99) 9 (13) 10 (14) 10 (16) 11 (17) 12 (18) 13 (19)<br />

800 400 “W1” 3.9 (99) 9 (13) 10 (14) 10 (16) 11 (17) 12 (18) 13 (19)<br />

1000 — “W1” 4.4 (112) 10 (15) 11 (17) 12 (19) 14 (20) 15 (22) 16 (23)<br />

1200 600 “W1” 5.1 (130) 12 (18) 14 (20) 15 (23) 16 (24) 18 (26) 19 (29)<br />

1350 800 “W1” 5.7 (145) 14 (21) 16 (24) 17 (26) 19 (29) 21 (31) 23 (34)<br />

1600 1000 “W1” 6.7 (170) 17 (26) 19 (29) 22 (32) 24 (35) 26 (38) 28 (42)<br />

2000 1200,1350 “W1” 8.2 (208) 22 (32) 25 (37) 28 (41) 30 (45) 33 (50) 36 (54)<br />

— 1600 “W1” 8.7 (221) 13 (19) 14 (21) 15 (23) 16 (24) 18 (26) 19 (28)<br />

2500 2000 “W1” 10.7 (272) 30 (44) 34 (50) 38 (56) 42 (62) 46 (68) 50 (74)<br />

3000 — “W2” 11.8 (300) 33 (49) 37 (55) 42 (63) 47 (70) 51 (76) 56 (83)<br />

3200 — “W2” 13.3 (335) 37 (55) 42 (63) 48 (72) 53 (79) 58 (86) 64 (95)<br />

4000 2500,3000,3200 “W2” 15.3 (389) 43 (64) 50 (75) 56 (83) 62 (92) 68 (101) 75 (112)<br />

5000 4000 “W2” 19.3 (491) 56 (83) 64 (95) 72 (107) 80 (119) 89 (132) 97 (145)<br />

15-10<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron Straight Section Busway<br />

Copper (225-5000 Ampere) and Aluminum (225-4000 Ampere)<br />

Revised on 07/07/17<br />

Selection<br />

Copper (225 - 5000Ampere)<br />

Base Catalog Number Guide<br />

Ampere<br />

3-Pole<br />

3-Pole<br />

Internal<br />

Ground<br />

3-Pole<br />

Isolated<br />

Ground<br />

4- Pole<br />

4-Pole 200%<br />

Neutral<br />

4-Pole<br />

Internal<br />

Ground<br />

4-Pole 200%<br />

Neutral<br />

Internal<br />

Ground<br />

4-Pole<br />

Isolated<br />

Ground<br />

4-Pole 200%<br />

Neutral<br />

Isolated<br />

Ground<br />

225 SX302C1 SX302C2 SX302C3 SX402C1 SX502C1 SX402C2 SX502C2 SX402C3 SX502C3<br />

400 SX304C1 SX304C2 SX304C3 SX404C1 SX504C1 SX404C2 SX504C2 SX404C3 SX504C3<br />

600 SX306C1 SX306C2 SX306C3 SX406C1 SX506C1 SX406C2 SX506C2 SX406C3 SX506C3<br />

800 SX308C1 SX308C2 SX308C3 SX408C1 SX508C1 SX408C2 SX508C2 SX408C3 SX508C3<br />

1000 SX310C1 SX310C2 SX310C3 SX410C1 SX510C1 SX410C2 SX510C2 SX410C3 SX510C3<br />

1200 SX312C1 SX312C2 SX312C3 SX412C1 SX512C1 SX412C2 SX512C2 SX412C3 SX512C3<br />

1350 SX313C1 SX313C2 SX313C3 SX413C1 SX513C1 SX413C2 SX513C2 SX413C3 SX513C3<br />

1600 SX316C1 SX316C2 SX316C3 SX416C1 SX516C1 SX416C2 SX516C2 SX416C3 SX516C3<br />

2000 SX320C1 SX320C2 SX320C3 SX420C1 SX520C1 SX420C2 SX520C2 SX420C3 SX520C3<br />

2500 SX325C1 SX325C2 SX325C3 SX425C1 SX525C1 SX425C2 SX525C2 SX425C3 SX525C3<br />

3000 SX330C1 SX330C2 SX330C3 SX430C1 SX530C1 SX430C2 SX530C2 SX430C3 SX530C3<br />

3200 SX332C1 SX332C2 SX332C3 SX432C1 SX532C1 SX432C2 SX532C2 SX432C3 SX532C3<br />

4000 SX340C1 SX340C2 SX340C3 SX440C1 SX540C1 SX440C2 SX540C2 SX440C3 SX540C3<br />

5000 SX350C1 SX350C2 SX350C3 SX450C1 SX550C1 SX450C2 SX550C2 SX450C3 SX550C3<br />

Aluminum (225 - 4000Ampere)<br />

Base Catalog Number Guide<br />

Ampere<br />

3-Pole<br />

3-Pole<br />

Internal<br />

Ground<br />

3-Pole<br />

Isolated<br />

Ground<br />

4- Pole<br />

4-Pole 200%<br />

Neutral<br />

4-Pole<br />

Internal<br />

Ground<br />

4-Pole 200%<br />

Neutral<br />

Internal<br />

Ground<br />

4-Pole<br />

Isolated<br />

Ground<br />

4-Pole 200%<br />

Neutral<br />

Isolated<br />

Ground<br />

225 SX302A1 SX302A2 SX302A3 SX402A1 SX502A1 SX402A2 SX502A2 SX402A3 SX502A3<br />

400 SX304A1 SX304A2 SX304A3 SX404A1 SX504A1 SX404A2 SX504A2 SX404A3 SX504A3<br />

600 SX306A1 SX306A2 SX306A3 SX406A1 SX506A1 SX406A2 SX506A2 SX406A3 SX506A3<br />

800 SX308A1 SX308A2 SX308A3 SX408A1 SX508A1 SX408A2 SX508A2 SX408A3 SX508A3<br />

1000 SX310A1 SX310A2 SX310A3 SX410A1 SX510A1 SX410A2 SX510A2 SX410A3 SX510A3<br />

1200 SX312A1 SX312A2 SX312A3 SX412A1 SX512A1 SX412A2 SX512A2 SX412A3 SX512A3<br />

1350 SX313A1 SX313A2 SX313A3 SX413A1 SX513A1 SX413A2 SX513A2 SX413A3 SX513A3<br />

1600 SX316A1 SX316A2 SX316A3 SX416A1 SX516A1 SX416A2 SX516A2 SX416A3 SX516A3<br />

2000 SX320A1 SX320A2 SX320A3 SX420A1 SX520A1 SX420A2 SX520A2 SX420A3 SX520A3<br />

2500 SX325A1 SX325A2 SX325A3 SX425A1 SX525A1 SX425A2 SX525A2 SX425A3 SX525A3<br />

3000 SX330A1 SX330A2 SX330A3 SX430A1 SX530A1 SX430A2 SX530A2 SX430A3 SX530A3<br />

3200 SX332A1 SX332A2 SX332A3 SX432A1 SX532A1 SX432A2 SX532A2 SX432A3 SX532A3<br />

4000 SX340A1 SX340A2 SX340A3 SX440A1 SX540A1 SX440A2 SX540A2 SX440A3 SX540A3<br />

15<br />

BUSWAY SYSTEMS<br />

Suffix Numbers<br />

Base Catalog Number Suffix<br />

Busway Type IP40 IP55 IP66 Nema 3R<br />

Feeder 0F 4F 6F 9F<br />

Plug-in 0P 4P — —<br />

One-sided Plug-in 0R 4R — —<br />

Product Category: BUSW<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-11


Sentron Busway Systems<br />

Elbows<br />

Revised on 04/30/18<br />

Selection<br />

15<br />

BUSWAY SYSTEMS<br />

Sentron Busway elbows provide a simple, convenient<br />

method of changing the direction (left, right, up or<br />

down) of a busway run. Two elbow styles are offered:<br />

elbow stack and elbow section.<br />

Flatwise Elbow Stacks, Dimensions (standard/min.)<br />

Dimensions Inches (mm)<br />

Ampere Rating<br />

“A”<br />

AL L-Rated<br />

225 — 1.00 (25)<br />

400 — 1.00 (25)<br />

600 — 1.00 (25)<br />

800 400 1.12 (28<br />

1000 600 2.00 (51)<br />

1200 800 2.50 (64)<br />

1350 1000 3.00 (76)<br />

1600 1200 3.50 (89)<br />

2000 1350,1600 4.62 (117)<br />

2500 2000 5.75 (146)<br />

3000 2500 7.00 (178)<br />

3200 2000 7.75 (197)<br />

4000 3000,3200 9.35 (237)<br />

CU M-Rated<br />

225 — 1.00 (25)<br />

400 — 1.00 (25)<br />

600 — 1.00 (25)<br />

800 400 1.00 (25)<br />

1000 — 1.12 (28)<br />

1200 600 1.25 (33)<br />

1350 800 2.00 (50)<br />

1600 1000 2.50 (64)<br />

2000 1200,1350 3.25 (83)<br />

— 1600 4.62 (117)<br />

2500 2000 4.50 (114)<br />

3000 — 5.00 (127)<br />

3200 — 5.75 (146)<br />

4000 2500,3000,3200 6.75 (171)<br />

5000 4000 8.87 (225)<br />

Note: Flatwise elbow stacks can be ordered as either right-hand (ESFR)<br />

or left-hand (ESFL) to follow the same nomenclature as an elbow section.<br />

The construction is identical and interchangeable.<br />

Flatwise Elbow Stacks<br />

Flatwise elbow stacks are used for left and right directional<br />

changes when the busway system is mounted flatwise in the<br />

horizontal plane (bus bars run parallel to the floor).<br />

Flat<br />

Suffix ESFR/ESFL<br />

Edgewise Elbow Stacks, Dimensions (standard/min.)<br />

Dimensions Inches (mm)<br />

Ampere Rating<br />

“A”<br />

AL L-Rated<br />

225 — 4.25 (108)<br />

400 — 4.25 (108)<br />

600 — 4.25 (108)<br />

800 400 4.25 (108)<br />

1000 600 4.25 (108)<br />

1200 800 4.25 (108)<br />

1350 1000 4.25 (108)<br />

1600 1200 4.25 (108)<br />

2000 1350,1600 4.25 (108)<br />

2500 2000 4.25 (108)<br />

3000 2500 4.25 (108)<br />

3200 2000 4.25 (108)<br />

CU M-Rated<br />

225 — 4.25 (108)<br />

400 — 4.25 (108)<br />

600 — 4.25 (108)<br />

800 400 4.25 (108)<br />

1000 — 4.25 (108)<br />

1200 600 4.25 (108)<br />

1350 800 4.25 (108)<br />

1600 1000 4.25 (108)<br />

2000 1200,1350 4.25 (108)<br />

— 1600 4.25 (108)<br />

2500 2000 4.25 (108)<br />

3000 — 4.25 (108)<br />

3200 — 4.25 (108)<br />

4000 2500,3000,3200 4.25 (108)<br />

5000 4000 4.25 (108)<br />

Note: Edge up and edge down elbow stacks are not interchangeable.<br />

Edgewise Elbow Stacks<br />

Edgewise elbow stacks create up and down directional changes.<br />

The “A” phase is on the inside of the bend for edge up elbow<br />

stacks. The “A” phase is on the outside of the bend for edge down<br />

elbow stacks.<br />

Edge Down<br />

Suffix ESED<br />

Edge Up<br />

Suffix ESEU<br />

15-12<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron Busway Systems<br />

Elbows<br />

Revised on 04/30/18<br />

Selection<br />

Flatwise Elbow Sections, Dimensions (standard/min.)<br />

Dimensions Inches (mm)<br />

Ampere Rating “A” ”B”<br />

AL L-Rated<br />

225 — 12 (305) 12 (305)<br />

400 — 12 (305) 12 (305)<br />

600 — 12 (305) 12 (305)<br />

800 400 12 (305) 12 (305)<br />

1000 600 12(305) 12 (305)<br />

1200 800 12 (305) 12 (305)<br />

1350 1000 12 (305) 12 (305)<br />

1600 1200 18 (457) 18 (457)<br />

2000 1350,1600 18 (457) 18 (457)<br />

2500 2000 18 (457) 18 (457)<br />

3000 2500 18 (457) 18 (457)<br />

3200 2000 18 (457) 18 (457)<br />

4000 3000,3200 24 (610) 24 (610)<br />

CU M-Rated<br />

225 — 12 (305) 12 (305)<br />

400 — 12 (305) 12 (305)<br />

600 — 12 (305) 12 (305)<br />

800 400 12 (305) 12 (305)<br />

1000 — 12 (305) 12 (305)<br />

1200 600 12 (305) 12 (305)<br />

1350 800 12 (305) 12 (305)<br />

1600 1000 12 (305) 12 (305)<br />

2000 1200,1350 12 (305) 12 (305)<br />

— 1600 18 (457) 18 (457)<br />

2500 2000 18 (457) 18 (457)<br />

3000 — 18 (457) 18 (457)<br />

3200 — 18 (457) 18 (457)<br />

4000 2500,3000,3200 18 (457) 18 (457)<br />

5000 4000 24 (610) 24 (610)<br />

Edgewise Elbow Sections, Dimensions (standard/min.)<br />

Dimensions Inches (mm)<br />

Ampere Rating “A” ”B”<br />

AL L-Rated<br />

225 — 10 (254) 10 (254)<br />

400 — 10 (254) 10 (254)<br />

600 — 10 (254) 10 (254)<br />

800 400 10 (254) 10 (254)<br />

1000 600 10 (254) 10 (254)<br />

1200 800 10 (254) 10 (254)<br />

1350 1000 10 (254) 10 (254)<br />

1600 1200 10 (254) 10 (254)<br />

2000 1350,1600 10 (254) 10 (254)<br />

2500 2000 10 (254) 10 (254)<br />

3000 2500 10 (254) 10 (254)<br />

3200 2000 10 (254) 10 (254)<br />

4000 3000,3200 10 (254) 10 (254)<br />

CU M-Rated<br />

225 — 10 (254) 10 (254)<br />

400 — 10 (254) 10 (254)<br />

600 — 10 (254) 10 (254)<br />

800 400 10 (254) 10 (254)<br />

1000 — 10 (254) 10 (254)<br />

1200 600 10 (254) 10 (254)<br />

1350 800 10 (254) 10 (254)<br />

1600 1000 10 (254) 10 (254)<br />

2000 1200,1350 10 (254) 10 (254)<br />

— 1600 10 (254) 10 (254)<br />

2500 2000 10 (254) 10 (254)<br />

3000 — 10 (254) 10 (254)<br />

3200 — 10 (254) 10 (254)<br />

4000 2500,3000,3200 10 (254) 10 (254)<br />

5000 4000 10 (254) 10 (254)<br />

Note : Odd angle elbow flatwise and edgewise elbow sections are available<br />

for angles 95° - 175° in 5° increments.<br />

Flatwise Elbow Sections<br />

Flatwise elbow sections are used for left and right directional<br />

changes when the busway system is mounted in the horizontal plane<br />

(bus bars run parallel to the floor). The joint stack assembly may be<br />

moved to the opposite leg to change the orientation from left to<br />

right/right to left.<br />

Flat Left<br />

Suffix ELFL<br />

Flat Right<br />

Suffix ELFR<br />

Edgewise Elbow Sections<br />

Edgewise elbow sections create up and down directional changes.<br />

The “A”phase bus bar lies on the inside of the bend for edge up<br />

elbows. The “A” phase bus bar lies on the outside of the bend for<br />

edge down elbows. The joint stack assembly on edgewise elbows<br />

can not be moved in order to change orientation from up to<br />

down/down to up. Sentron Busway elbow sections are shipped with<br />

a joint stack assembly on one end for direct connection to the<br />

busway system.<br />

Edge Up<br />

Suffix ELEU<br />

Edge Down<br />

Suffix ELED<br />

15<br />

BUSWAY SYSTEMS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-13


Sentron Busway Systems<br />

Offsets<br />

Selection<br />

Offsets can be utilized to solve difficult contour<br />

problems and save space. In applications where space<br />

does not allow for two connected elbows, a single<br />

offset can bypass an obstruction. All offsets are<br />

supplied with one joint stack assembly.<br />

15<br />

BUSWAY SYSTEMS<br />

Flatwise Offsets, Dimensions (standard/min.)<br />

Dimensions Inches (mm)<br />

Ampere Rating *“A” ”B” ”C”<br />

AL L-Rated<br />

225 — 12 (305) 5 (127) 12 (305)<br />

400 — 12 (305) 5 (127) 12 (305)<br />

600 — 12 (305) 5 (127) 12 (305)<br />

800 400 12 (305) 5 (127) 12 (305)<br />

1000 600 12 (305) 5 (127) 12 (305)<br />

1200 800 12 (305) 5 (127) 12 (305)<br />

1350 1000 12 (305) 5 (127) 12 (305)<br />

1600 1200 18 (457) 5 (127) 18 (457)<br />

2000 1350,1600 18 (457) 5 (127) 18 (457)<br />

2500 2000 18 (457) 5 (127) 18 (457)<br />

3000 2500 18 (457) 5 (127) 18 (457)<br />

3200 2000 18 (457) 5 (127) 18 (457)<br />

4000 3000,3200 24 (610) 8 (203) 24 (610)<br />

CU M-Rated<br />

225 — 12 (305) 5 (127) 12 (305)<br />

400 — 12 (305) 5 (127) 12 (305)<br />

600 — 12 (305) 5 (127) 12 (305)<br />

800 400 12 (305) 5 (127) 12 (305)<br />

1000 — 12 (305) 5 (127) 12 (305)<br />

1200 600 12 (305) 5 (127) 12 (305)<br />

1350 800 12 (305) 5 (127) 12 (305)<br />

1600 1000 12 (305) 5 (127) 12 (305)<br />

2000 1200,1350 12 (305) 5 (127) 12 (305)<br />

— 1600<br />

2500 2000 18 (457) 5 (127) 18 (457)<br />

3000 — 18 (457) 5 (127) 18 (457)<br />

3200 — 18 (457) 5 (127) 18 (457)<br />

4000 2500,3000,3200 18 (457) 5 (127) 18 (457)<br />

5000 4000 24 (610) 8 (203) 24 (610)<br />

Flat Right<br />

Suffix OFFR<br />

Flat Left<br />

Suffix OFFL<br />

Edgewise Offsets, Dimensions (standard/min.)<br />

Dimensions Inches (mm)<br />

Ampere Rating *“A” ”B” ”C”<br />

AL L-Rated<br />

225 — 10 (254) 6 (152) 10 (254)<br />

400 — 10 (254) 6 (152) 10 (254)<br />

600 — 10 (254) 6 (152) 10 (254)<br />

800 400 10 (254) 6 (152) 10 (254)<br />

1000 600 10 (254) 6 (152) 10 (254)<br />

1200 800 10 (254) 6 (152) 10 (254)<br />

1350 1000 10 (254) 6 (152) 10 (254)<br />

1600 1200 10 (254) 6 (152) 10 (254)<br />

2000 1350,1600 10 (254) 6 (152) 10 (254)<br />

2500 2000 10 (254) 6 (152) 10 (254)<br />

3000 2500 10 (254) 6 (152) 10 (254)<br />

3200 2000 10 (254) 6 (152) 10 (254)<br />

4000 3000,3200 10 (254) 6 (152) 10 (254)<br />

CU M-Rated<br />

225 — 10 (254) 6 (152) 10 (254)<br />

400 — 10 (254) 6 (152) 10 (254)<br />

600 — 10 (254) 6 (152) 10 (254)<br />

800 400 10 (254) 6 (152) 10 (254)<br />

1000 — 10 (254) 6 (152) 10 (254)<br />

1200 600 10 (254) 6 (152) 10 (254)<br />

1350 800 10 (254) 6 (152) 10 (254)<br />

1600 1000 10 (254) 6 (152) 10 (254)<br />

2000 1200,1350 10 (254) 6 (152) 10 (254)<br />

— 1600 10 (254) 6 (152) 10 (254)<br />

2500 2000 10 (254) 6 (152) 10 (254)<br />

3000 — 10 (254) 6 (152) 10 (254)<br />

3200 — 10 (254) 6 (152) 10 (254)<br />

4000 2500,3000,3200 10 (254) 6 (152) 10 (254)<br />

5000 4000 10 (254) 6 (152) 10 (254)<br />

*Note: Leg Dimensions A and C have been reversed from prior publications.<br />

Edge Up<br />

Suffix OFEU<br />

Edge Down<br />

Suffix OFED<br />

15-14<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron Busway Systems<br />

Revised on 04/30/18<br />

Combinations<br />

Selection<br />

Combinations are used to create edge to flat and flat<br />

to edge changes in the busway run. One joint stack<br />

assembly is shipped with combination.<br />

Flat Right - Edge Up<br />

Suffix CORU<br />

Flat Left - Edge Up<br />

Suffix COLU<br />

See drawings for minimum dimensions. Consult<br />

Busway Order Service for information on custom<br />

lengths.<br />

Combinations, Dimensions (standard/min.)<br />

Dimensions Inches (mm)<br />

Ampere Rating *“A” ”B” ”C”<br />

AL L-Rated<br />

225 — 10 (254) 8 (203) 12 (305)<br />

400 — 10 (254) 8 (203) 12 (305)<br />

600 — 10 (254) 8 (203) 12 (305)<br />

800 400 10 (254) 8 (203) 12 (305)<br />

1000 600 10 (254) 8 (203) 12 (305)<br />

1200 800 10 (254) 8 (203) 12 (305)<br />

1350 1000 10 (254) 8 (203) 12 (305)<br />

1600 1200 10 (254) 12 (305) 18 (457)<br />

2000 1350,1600 10 (254) 12 (305) 18 (457)<br />

2500 2000 10 (254) 12 (305) 18 (457)<br />

3000 2500 10 (254) 12 (305) 18 (457)<br />

3200 2000 10 (254) 12 (305) 18 (457)<br />

4000 3000,3200 10 (254) 16 (406) 24 (610)<br />

CU M-Rated<br />

225 — 10 (254) 8 (203) 12 (305)<br />

400 — 10 (254) 8 (203) 12 (305)<br />

600 — 10 (254) 8 (203) 12 (305)<br />

800 400 10 (254) 8 (203) 12 (305)<br />

1000 — 10 (254) 8 (203) 12 (305)<br />

1200 600 10 (254) 8 (203) 12 (305)<br />

1350 800 10 (254) 8 (203) 12 (305)<br />

1600 1000 10 (254) 8 (203) 12 (305)<br />

2000 1200,1350 10 (254) 8 (203) 12 (305)<br />

— 1600 10 (254) 12 (305) 18 (457)<br />

2500 2000 10 (254) 12 (305) 18 (457)<br />

3000 — 10 (254) 12 (305) 18 (457)<br />

3200 — 10 (254) 12 (305) 18 (457)<br />

4000 2500,3000,3200 10 (254) 12 (305) 18 (457)<br />

5000 4000 10 (254) 16 (406) 24 (610)<br />

Edge Up - Flat Left<br />

Suffix COUL<br />

Flat Right - Edge Down<br />

Suffix CORD<br />

Edge Up - Flat Right<br />

Suffix COUR<br />

Flat Left - Edge Down<br />

Suffix COLD<br />

15<br />

BUSWAY SYSTEMS<br />

*Note: Leg Dimensions A and C have been reversed from prior publications.<br />

Edge Down - Flat Left<br />

Suffix CODL<br />

Edge Down - Flat Right<br />

Suffix CODR<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-15


Sentron Busway Systems<br />

Tees<br />

Selection<br />

Tees are used to simplify directional and plane<br />

orientation changes in a busway system. Tees can<br />

make 90° bends left or right, and up and down along<br />

the busway run. All tees are supplied with two joint<br />

stack assemblies.<br />

15<br />

BUSWAY SYSTEMS<br />

Flatwise Tees, Dimensions (standard/min.)<br />

Dimensions Inches (mm)<br />

Ampere Rating<br />

“A”, ”B”, ”C”<br />

AL L-Rated<br />

225 — 12 (305)<br />

400 — 12 (305)<br />

600 — 12 (305)<br />

800 400 12 (305)<br />

1000 600 12 (305)<br />

1200 800 12 (305)<br />

1350 1000 12 (305)<br />

1600 1200 18 (457)<br />

2000 1350,1600 18 (457)<br />

2500 2000 18 (457)<br />

3000 2500 18 (457)<br />

3200 2000 18 (457)<br />

4000 3000,3200 24 (610)<br />

CU M-Rated<br />

225 — 12 (305)<br />

400 — 12 (305)<br />

600 — 12 (305)<br />

800 400 12 (305)<br />

1000 — 12 (305)<br />

1200 600 12 (305)<br />

1350 800 12 (305)<br />

1600 1000 12 (305)<br />

2000 1200,1350 12 (305)<br />

— 1600 18 (457)<br />

2500 2000 18 (457)<br />

3000 — 18 (457)<br />

3200 — 18 (457)<br />

4000 2500,3000,3200 18 (457)<br />

5000 4000 24 (610)<br />

Flatwise Tees<br />

Flatwise tees are used to create left and right branches.<br />

Flat Right<br />

Suffix TEFR<br />

Flat Left<br />

Suffix TEFL<br />

Edgewise Tees, Dimensions (standard/min.)<br />

Dimensions Inches (mm)<br />

Ampere Rating<br />

“D”<br />

AL L-Rated<br />

225 — 13 (330)<br />

400 — 13 (330)<br />

600 — 13 (330)<br />

800 400 13 (330)<br />

1000 600 13 (330)<br />

1200 800 18 (457)<br />

1350 1000 18 (457)<br />

1600 1200 18 (457)<br />

2000 1350,1600 18 (457)<br />

2500 2000 27 (686)<br />

3000 2500 27 (686)<br />

3200 2000 27 (686)<br />

4000 3000,3200 29 (737)<br />

CU M-Rated<br />

225 — 13 (330)<br />

400 — 13 (330)<br />

600 — 13 (330)<br />

800 400 13 (330)<br />

1000 — 13 (330)<br />

1200 600 13 (330)<br />

1350 800 13 (330)<br />

1600 1000 18 (457)<br />

2000 1200,1350 18 (457)<br />

— 1600 18 (457)<br />

2500 2000 18 (457)<br />

3000 — 27 (686)<br />

3200 — 27 (686)<br />

4000 2500,3000,3200 27 (686)<br />

5000 4000 29 (737)<br />

Edgewise Tees<br />

Edgewise tees are used to create branches that stem up or down<br />

from the busway run.<br />

Edge Up<br />

Suffix TEEU<br />

Edge Down<br />

Suffix TEED<br />

a<br />

a 12.0" (305mm) For Isolated Ground.<br />

15-16<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron Busway Systems<br />

End Tap Boxes<br />

Revised on 04/30/18<br />

Selection<br />

End tap boxes are non-fusible devices used to connect cable and conduit to the end of a<br />

busway run or where busway runs connect without the need for over-current protection. End<br />

tap boxes may be installed at the end or beginning of a run. Vertical end tap boxes and<br />

horizontal end tap boxes can be installed in both horizontal and vertical applications. Extended<br />

end tap boxes are available if the application requires additional wire bending space. One joint<br />

stack assembly is shipped with each end tap box.<br />

Standard and Extended Horizontal End Tap Boxes, Dimensions<br />

Cable Lugs<br />

Dimensions Inches (mm) Wire Bend Space Per Phase & Neutral Ground<br />

Ampere Rating “A” “B” Std. “B” Ext. “C” Std. “C” Ext. Qty. Size Lugs a<br />

AL L-Rated<br />

225 — 13 (330) 30 (762) 34 (863) 17 (432) 21 (533) 1 a 1<br />

400 — 13 (330) 30 (762) 34 (863) 17 (432) 21 (533) 1 b 1<br />

600 — 13 (330) 30 (762) 34 (863) 17 (432) 21 (533) 2 b 1<br />

800 400 13 (330) 30 (762) 34 (863) 17 (432) 21 (533) 3 b 1<br />

1000 600 13 (330) 30 (762) 34 (863) 17 (432) 21 (533) 4 b 1<br />

1200 800 18 (457) 33 (838) 37 (940) 20 (508) 24 (610) 4 b 1<br />

1350 1000 18 (457) 33 (838) 37 (940) 20 (508) 24 (610) 4 b 1<br />

1600 1200 18 (457) 33 (838) 37 (940) 20 (508) 24 (610) 5 b 1<br />

2000 1350,1600 18 (457) 33 (838) 37 (940) 20 (508) 24 (610) 6 b 2<br />

2500 2000 27 (686) 33 (838) 37 (940) 20 (508) 24 (610) 8 b 2<br />

3000 2500 27 (686) 33 (838) 37 (940) 20 (508) 24 (610) 9 b 2<br />

3200 2000 27 (686) 33 (838) 37 (940) 20 (508) 24 (610) 9 b 2<br />

4000 3000,3200 29 (737) 33 (838) 37 (940) 20 (508) 24 (610) 12 b 3<br />

CU M-Rated<br />

225 — 13 (330) 30 (762) 34 (863) 17 (432) 21 (533) 1 a 1<br />

400 — 13 (330) 30 (762) 34 (863) 17 (432) 21 (533) 1 b 1<br />

600 — 13 (330) 30 (762) 34 (863) 17 (432) 21 (533) 2 b 1<br />

800 400 13 (330) 30 (762) 34 (863) 17 (432) 21 (533) 3 b 1<br />

1000 — 13 (330) 30 (762) 34 (863) 17 (432) 21 (533) 4 b 1<br />

1200 600 13 (330) 33 (838) 37 (940) 20 (508) 24 (610) 4 b 1<br />

1350 800 13 (330) 33 (838) 37 (940) 20 (508) 24 (610) 4 b 1<br />

1600 1000 18 (457) 33 (838) 37 (940) 20 (508) 24 (610) 5 b 1<br />

2000 1200,1350 18 (457) 33 (838) 37 (940) 20 (508) 24 (610) 6 b 2<br />

— 1600 18 (457) 33 (838) 37 (940) 20 (508) 24 (610) 5 b 1<br />

2500 2000 18 (457) 33 (838) 37 (940) 20 (508) 24 (610) 8 b 2<br />

3000 — 27 (686) 33 (838) 37 (940) 20 (508) 24 (610) 9 b 2<br />

3200 — 27 (686) 33 (838) 37 (940) 20 (508) 24 (610) 9 b 2<br />

4000 2500,3000,3200 27 (686) 33 (838) 37 (940) 20 (508) 24 (610) 12 b 3<br />

5000 4000 29 (737) 33 (838) 37 (940) 20 (508) 24 (610) 15 b 4<br />

Horizontal End Tap Box<br />

Suffix ETHS (Standard)<br />

Suffix ETHX (Extended)<br />

15<br />

BUSWAY SYSTEMS<br />

Standard and Extended Vertical End Tap Boxes, Dimensions<br />

Cable Lugs<br />

Dimensions Inches (mm) Wire Bend Space Per Phase & Neutral Ground<br />

Ampere Rating “A” “B” Std. “B” Ext. “C” Std. “C” Ext. Qty. Size Lugs a<br />

AL L-Rated<br />

225 — 13 (330) 25 (635) 29 (737) 17 (432) 21 (533) 1 a 1<br />

400 — 13 (330) 25 (635) 29 (737) 17 (432) 21 (533) 1 b 1<br />

600 — 13 (330) 25 (635) 29 (737) 17 (432) 21 (533) 2 b 1<br />

800 400 13 (330) 25 (635) 29 (737) 17 (432) 21 (533) 3 b 1<br />

1000 600 13 (330) 25 (635) 29 (737) 17 (432) 21 (533) 4 b 1<br />

1200 800 18 (457) 28 (711) 32 (813) 20 (508) 24 (610) 4 b 1<br />

1350 1000 18 (457) 28 (711) 32 (813) 20 (508) 24 (610) 4 b 1<br />

1600 1200 18 (457) 28 (711) 32 (813) 20 (508) 24 (610) 5 b 1<br />

2000 1350,1600 18 (457) 28 (711) 32 (813) 20 (508) 24 (610) 6 b 2<br />

2500 2000 27 (686) 28 (711) 32 (813) 20 (508) 24 (610) 8 b 2<br />

3000 2500 27 (686) 28 (711) 32 (813) 20 (508) 24 (610) 9 b 2<br />

3200 2000 29 (737) 28 (711) 32 (813) 20 (508) 24 (610) 9 b 2<br />

4000 3000,3200 29 (737) 28 (711) 32 (813) 20 (508) 24 (610) 12 b 3<br />

CU M-Rated<br />

225 — 13 (330) 25 (635) 29 (737) 17 (432) 21 (533) 1 a 1<br />

400 — 13 (330) 25 (635) 29 (737) 17 (432) 21 (533) 1 b 1<br />

600 — 13 (330) 25 (635) 29 (737) 17 (432) 21 (533) 2 b 1<br />

800 400 13 (330) 25 (635) 29 (737) 17 (432) 21 (533) 3 b 1<br />

1000 — 13 (330) 25 (635) 29 (737) 17 (432) 21 (533) 4 b 1<br />

1200 600 13 (330) 28 (711) 32 (813) 20 (508) 24 (610) 4 b 1<br />

1350 800 13 (330) 28 (711) 32 (813) 20 (508) 24 (610) 4 b 1<br />

1600 1000 18 (457) 28 (711) 32 (813) 20 (508) 24 (610) 5 b 1<br />

2000 1200,1350 18 (457) 28 (711) 32 (813) 20 (508) 24 (610) 6 b 2<br />

— 1600 18 (457) 28 (711) 32 (813) 20 (508) 24 (610) 5 b 1<br />

2500 2000 18 (457) 28 (711) 32 (813) 20 (508) 24 (610) 8 b 2<br />

3000 — 27 (686) 28 (711) 32 (813) 20 (508) 24 (610) 9 b 2<br />

3200 — 27 (686) 28 (711) 32 (813) 20 (508) 24 (610) 9 b 2<br />

4000 2500,3000,3200 27 (686) 28 (711) 32 (813) 20 (508) 24 (610) 12 b 3<br />

5000 4000 29 (737) 28 (711) 32 (813) 20 (508) 24 (610) 15 b 4<br />

Vertical End Tap Box<br />

Suffix ETVS (Standard)<br />

Suffix ETVX (Extended)<br />

a #6 AWG -350 kcmil, Cu/AI. b #4 AWG -600 kcmil, Cu/AI. c 24.0" (610mm) for isolated ground.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-17


Sentron Busway Systems<br />

Center Tap Boxes<br />

Revised on 04/30/18<br />

Selection<br />

Center tap boxes are non-fusible devices utilized to feed to or take off power from the busway<br />

run. When loads served by the busway run do not require over-current protection, center tap<br />

boxes may be used. If the application requires additional wiring bending space, extended<br />

center tap boxes are available. One joint stack assembly is provided with each center tap box.<br />

15<br />

BUSWAY SYSTEMS<br />

Standard and Extended Center End Tap Boxes, Dimensions<br />

Cable Lugs<br />

Per Phase &<br />

Dimensions Inches (mm) Wire Bend Space Neutral Ground<br />

Ampere Rating “A”Std. “B” “D” “A” Ext.. “C” Std. “C” Ext. Qty. Size Lugs a<br />

AL L-Rated<br />

225 — 25 (635) 16 (406) 3.9 (99) 29 (737) 17 (432) 21 (533) 1 a 1<br />

225 — 25 (635) 16 (406) 3.9 (99) 29 (737) 17 (432) 21 (533) 1 b 1<br />

400 — 25 (635) 16 (406) 3.9 (99) 29 (737) 17 (432) 21 (533) 1 b 1<br />

600 — 25 (635) 16 (406) 3.9 (99) 29 (737) 17 (432) 21 (533) 2 b 1<br />

800 400 25 (635) 16 (406) 4.2 (107) 29 (737) 17 (432) 21 (533) 3 b 1<br />

1000 600 25 (635) 16 (406) 4.6 (117) 29 (737) 17 (432) 21 (533) 4 b 1<br />

1200 800 29 (737) 16 (406) 5.2 (132) 33 (838) 20 (508) 24 (610) 4 b 1<br />

1350 1000 29 (737) 16 (406) 5.7 (145) 33 (838) 20 (508) 24 (610) 4 b 1<br />

1600 1200 33 (838) 20 (508) 6.3 (160) 37 (940) 20 (508) 24 (610) 5 b 1<br />

2000 1350,1600 33 (838) 20 (508) 7.4 (188) 37 (940) 20 (508) 24 (610) 6 b 2<br />

2500 2000 37 (940) 24 (610) 8.7 (221) 41 (1041) 20 (508) 24 (610) 8 b 2<br />

3000 2500 37 (940) 24 (610) 9.7 (246) 41 (1041) 20 (508) 24 (610) 9 b 2<br />

3200 2000 37 (940) 24 (610) 9.7 (246) 41 (1041) 20 (508) 24 (610) 9 b 2<br />

4000 3000,3200 45 (1143) 28 (711) 11.9 (302) 49 (1245) 20 (508) 24 (610) 12 b 3<br />

CU M-Rated<br />

225 — 25 (635) 16 (406) 3.9 (99) 29 (737) 17 (432) 21 (533) 1 b 1<br />

400 — 25 (635) 16 (406) 3.9 (99) 29 (737) 17 (432) 21 (533) 1 b 1<br />

600 — 25 (635) 16 (406) 3.9 (99) 29 (737) 17 (432) 21 (533) 2 b 1<br />

800 400 25 (635) 16 (406) 3.9 (99) 29 (737) 17 (432) 21 (533) 3 b 1<br />

1000 — 25 (635) 16 (406) 4.2 (107) 29 (737) 18 (457) 22 (559) 4 b 1<br />

1200 600 29 (737) 16 (406) 4.5 (114) 33 (838) 22 (559) 26 (660) 4 b 1<br />

1350 800 29 (737) 16 (406) 4.8 (122) 33 (838) 21 (533) 25 (635) 4 b 1<br />

1600 1000 29 (737) 20 (508) 5.3 (135) 33 (838) 21 (533) 25 (635) 5 b 1<br />

2000 1200,1350 29 (737) 20 (508) 6.1 (155) 33 (838) 20 (508) 24 (610) 6 b 2<br />

— 1600 33 (838) 20 (508) 6.3 (160) 37 (940) 20 (508) 24 (610) 5 b 1<br />

2500 2000 33 (838) 24 (610) 7.3 (185) 37 (940) 23 (584) 17 (432) 8 b 2<br />

3000 — 33 (838) 24 (610) 7.9 (201) 37 (940) 20 (508) 24 (610) 9 b 2<br />

3200 — 33 (838) 24 (610) 7.9 (201) 37 (940) 20 (508) 24 (610) 9 b 2<br />

4000 2500,3000,<br />

3200 37 (940) 28 (711) 9.4 (239) 41 (1041) 20 (508) 24 (610) 12 b 3<br />

5000 4000 40(1016) 34 (863) 11.7(297) 44 (1118) 19 (483) 23 (584) 15 b 4<br />

Center Tap Box<br />

Suffix CTBS (Standard)<br />

Suffix CTBX (Extended)<br />

a #6 AWG -350 kcmil, Cu/AI.<br />

b #4 AWG -600 kcmil, Cu/AI.<br />

c 24.0" (610mm) for isolated ground.<br />

15-18<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


NCBA<br />

Sentron Busway Systems<br />

Joint Mounted Tap Boxes<br />

Revised on 06/30/18<br />

Selection<br />

The joint mounted tap box (JMTB) is<br />

used to tap off power via the busway<br />

joint. This device does not provide<br />

over-current protection and therefore,<br />

must be installed in compliance with<br />

NEC 240.21(B) a . The small footprint is<br />

ideal for space limited applications. The<br />

JMTB is compatible with Power Mod,<br />

Lighting Panels, Power Panels, and<br />

Switchboards 1200A and lower.<br />

Horizontal Orientation JMTB<br />

"A" LENGTH<br />

JOINT -<br />

36" MINIMUM<br />

120" MAXIMUM<br />

5.00"<br />

BUSWAY<br />

DEPTH<br />

5.3"<br />

EXIT<br />

ACCESS PANEL<br />

LUG DIRECTION<br />

16.5"<br />

OVERALL DEPTH<br />

18.0"<br />

CENTERED<br />

ON JOINT<br />

"W"<br />

BUSWAY WIDTH<br />

5.0"<br />

BUSWAY DEPTH<br />

LOCKING PROVISION<br />

ACCESS PANEL<br />

5.3"<br />

EXIT<br />

18.0"<br />

CENTERED<br />

ON JOINT<br />

Product Features<br />

n Lug Orientation: Vertical or Horizontal<br />

n Maximum Voltage: 600V<br />

n Maximum UL Short Circuit Rating:<br />

150kA b<br />

n Amperage Range: 100- 1200A<br />

n Lug Type: Compression Only<br />

"B" LENGTH<br />

JOINT -<br />

18" MINIMUM<br />

25.0"<br />

BUSWAY TO END OF COVER<br />

"W"<br />

BUSWAY WIDTH<br />

25.0"<br />

BUSWAY TO END OF COVER<br />

STD 4.0"<br />

FLUSH 2.5"<br />

BUSWAY<br />

TO REAR<br />

OF JMTB<br />

15<br />

Vertical Orientation JMTB<br />

5.0"<br />

BUSWAY<br />

DEPTH<br />

16.5"<br />

OVERALL DEPTH<br />

15.3"<br />

BOX DEPTH<br />

ACCESS PANEL<br />

LUG<br />

DIRECTION<br />

24.0"<br />

HEIGHT<br />

18.3"<br />

OF JOINT<br />

TO EDGE OF COVER<br />

20.0"<br />

BUSWAY TO<br />

EDGE OF COVER<br />

STD 4.0"<br />

OF EXIT OPENINGS IS FLUSH 2.5"<br />

5.3 INCHES FROM REAR TO REAT<br />

OF JMTB<br />

OF JMTB<br />

"W"<br />

BUSWAY<br />

WIDTH<br />

BUSWAY<br />

SECTION 2<br />

"A" LENGTH<br />

(OVERALL)<br />

44" MINIMUM<br />

120" MAXIMUM<br />

"B" LENGTH<br />

JOINT -<br />

BUSWAY SECTION 1<br />

(INCLUDES STD JOINT)<br />

18" MINIMUM<br />

Configuration Types<br />

Given a vertical bus run, the JMTB can<br />

be configured such that it is on the<br />

Left, Right, or Both sides. The JMTB<br />

is shipped from the factory installed on<br />

the busway.<br />

When installed on vertical busway, the<br />

lug orientation matches the orientation<br />

of the tap box. If using the horizontal<br />

JMTB the lug orientation will be left/<br />

right, if vertical JMTB it will be up/<br />

down.<br />

The standard JMTB extends 4" beyond<br />

the rear plane of the busway however<br />

a flush mount variation is available<br />

extending 2.5" from the rear of the<br />

busway.<br />

Compression Lugs<br />

Wire<br />

size<br />

Straight Lug<br />

Catalog Number<br />

Stacking Lug<br />

Catalog Number<br />

1/0 AL1/0-NTN ASL1/0-NTN<br />

2/0 AL2/0-NTN ASL2/0-NTN<br />

3/0 AL3/0-NTN ASL3/0-NTN<br />

4/0 AL4/0-NTN ASL4/0-NTN<br />

250 AL250-NTN ASL250-NTN<br />

300 AL300-NTN ASL300-NTN<br />

350 AL350-NTN ASL350-NTN<br />

Compression Lugs<br />

The JMTB requires compression lugs,<br />

which aid in minimizing product size.<br />

The JMTB is shipped with UL listed<br />

crimp type compression lugs, which are<br />

sized to the amperage of the load side<br />

device.<br />

Should additional lugs be required,<br />

please reference the table below.<br />

The JMTB utilizes general purpose<br />

aluminum 2 hole NEMA lugs,<br />

compatible with Aluminum and Copper<br />

wire. Homac AL-N series or equivalent<br />

are recommended. c<br />

If housing ground is selected the JMTB<br />

will contain a standard 4-hole NEMA<br />

pattern on a dedicated ground bar. If<br />

internal/isolated ground is selected, two<br />

ground bars will be included, each with<br />

the standard NEMA 4-hole pattern.<br />

BUSWAY SYSTEMS<br />

a This device requires compliance with NEC 240.21(B),<br />

see <strong>2017</strong> NEC, commonly referred to as the 10ft feeder<br />

tap rule. Feeder tap conductors cannot be over 10ft<br />

without overcurrent protection. Main circuit protection<br />

device is required downsteam. Please reference the<br />

NEC before using this device.<br />

b For series ratings reference the UL short circuit table in<br />

the Technical Data section.<br />

c Replacement lugs to be supplied by others.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-19


Sentron Busway Systems<br />

TBNK Fittings for Joint Mounted Tap Boxes<br />

Revised on 06/30/19<br />

Selection<br />

TBNK flexible fittings<br />

TBNK flexible fittings are a UL listed, factory installed series<br />

of wireway couplings for use with Sentron Joint Mounted Tap<br />

Boxes (JMTB’s). TBNK fittings provide a nominal 4.25” long<br />

flexible wireway for coupling the JMTB and rigidly mounted<br />

downstream equipment. TBNK fittings allow for expansion<br />

and contraction of the Busway absorbing up to an inch of<br />

movement. Available in 4, 6, and 8-inch sizes, TBNK fittings<br />

are suitable for a wide range of equipment amperages and<br />

cabling requirements. TBNK fittings if desired should be<br />

selected when ordering Sentron JMTB’s.<br />

Horizontal JMTB with TBNK<br />

15<br />

BUSWAY SYSTEMS<br />

Installation and Grounding<br />

TBNK flexible fittings must be field installed onto downstream<br />

equipment. JMTB’s ordered with TBNK fittings include<br />

Installation Instructions and a template for making the<br />

required cut-out in the downstream equipment enclosure.<br />

Location of equipment, cut out and cabling must comply with<br />

applicable standards including NEC, Local Building Codes<br />

and any other authorities having jurisdiction. Consult codes<br />

in advance to assure compliance. The JMTB is shipped from<br />

the factory with a braided copper ground cable riveted onto<br />

the TBNK. During installation, the opposite end of the ground<br />

cable must be connected to the enclosure of the downstream<br />

equipment. The Installation Instructions provide details of the<br />

ground cable installation procedure.<br />

Vertical JMTB with TBNK<br />

TBNK flexible fittings<br />

Catalog<br />

Number Cutout Size Wireway Size<br />

Maximum<br />

Cable Size<br />

TBNK4 3.8”x 3.8” 4”x 4” (16 sq. inch) 900MCM<br />

TBNK6 5.8”x 5.8” 6”x 6” (36 sq. inch) 500MCM<br />

TBNK8 7.8”x 7.8” 8”x 8” (64 sq. inch) 4/0<br />

15-20<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron Busway Systems<br />

TBNK Fittings for Joint Mounted Tap Boxes<br />

Revised on 06/30/19<br />

Technical data<br />

TBNK4, TBNK6 and TBNK8<br />

15<br />

TBNK cut out pattern<br />

BUSWAY SYSTEMS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-21


Sentron Busway Systems<br />

Expansion Fittings<br />

Revised on 06/30/18<br />

Selection<br />

15<br />

BUSWAY SYSTEMS<br />

Expansion Fittings, Dimensions (standard/min.)<br />

Dimensions Inches (mm)<br />

Ampere Rating<br />

“A”<br />

AL L-Rated<br />

225 — 13 (330)<br />

400 — 13 (330)<br />

600 — 13 (330)<br />

800 400 13 (330)<br />

1000 600 13 (330)<br />

1200 800 18 (457)<br />

1350 1000 18 (457)<br />

1600 1200 18 (457)<br />

2000 1350,1600 18 (457)<br />

2500 2000 23 (584)<br />

3000 2500 23 (584)<br />

3200 2000 25 (635)<br />

4000 3000,3200 25 (635)<br />

CU M-Rated<br />

225 — 13 (330)<br />

400 — 13 (330)<br />

600 — 13 (330)<br />

800 400 13 (330)<br />

1000 — 13 (330)<br />

1200 600 13 (330)<br />

1350 800 13 (330)<br />

1600 1000 18 (457)<br />

2000 1200,1350 18 (457)<br />

— 1600 18 (457)<br />

2500 2000 18 (457)<br />

3000 — 23 (584)<br />

3200 — 23 (584)<br />

4000 2500,3000,3200 23 (584)<br />

5000 4000 25 (635)<br />

Expansion Fittings<br />

Expansion fittings accommodate for expansion and contraction of a<br />

busway run and building movement. Expansion fittings typically are<br />

installed in the center of long busway runs, and at the beginning of<br />

riser runs (within the first 20ft of vertical busway when total vertical<br />

run length is equal to or greater then 40ft) to minimize stress on the<br />

lower most device or where a busway run crosses an expansion joint<br />

of a building.<br />

Qty (1) Expansion Section should be used for every 200ft of<br />

continuous Busway run length, at every transition to a vertical run, and<br />

at each building expansion joint. The Busway run must be positioned<br />

accordingly to accommodate the Expansion Section(s).<br />

Expansion Fitting<br />

Suffix XPFT<br />

Flush Mount Expansion Fitting<br />

Often useful in riser application, flush mount expansion fittings allow<br />

for the busway to be positioned closer to building walls (reference<br />

page 15-36 for minimum required clearances). The flush mount design<br />

shifts the centerline of the busway up or down by 5 in. on the 20 in.<br />

height axis shown above.<br />

a 24.0" (610mm) for isolated ground.<br />

15-22<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron Busway Systems<br />

Reducers and Phase Rotation Fittings<br />

Revised on 01/31/20<br />

Selection<br />

Fused Reducers, Dimensions (standard/min)<br />

Dimensions A Inches (mm)<br />

X1 Ampere Rating DIM B = 20.00 DIM B = 24.00<br />

AL L-Rated X2 < 2000 3200 > X2 2000 X2 3200<br />

225 — 10.5 (267) — —<br />

400 — 10.5 (267) — —<br />

600 — 10.5 (267) — —<br />

800 400 10.5 (267) — —<br />

1000 600 10.5 (267) — —<br />

1200 800 10.5 (267) — —<br />

1350 1000 15.0 (381) — —<br />

1600 1200 15.0 (381) — —<br />

2000 1350,1600 15.0 (381) — —<br />

2500 2000 20.0 (508) 25.0 (635) —<br />

3000 2500 20.0 (508) 25.0 (635) —<br />

3200 — 25.0 (635) 30.0 (762) —<br />

4000 3000,3200 25.0 (635) 30.0 (762) 30.0 (762)<br />

CU M-Rated X2 < 2000 3200 > X2 2000 X2 3200<br />

225 — 10.5 (267) — —<br />

400 — 10.5 (267) — —<br />

600 — 10.5 (267) — —<br />

800 225, 400 10.5 (267) — —<br />

1000 — 10.5 (267) — —<br />

1200 600 10.5 (267) — —<br />

1350 800 10.5 (267) — —<br />

1600 1000 10.5 (267) — —<br />

2000 1200, 1350 15.0 (381) — —<br />

— 1600 15.0 (381) — —<br />

2500 2000 15.0 (381) 20.0 (508) —<br />

3000 — 20.0 (508) 25.0 (635) —<br />

3200 — 20.0 (508) 25.0 (635) —<br />

4000<br />

2500, 3000,<br />

3200<br />

20.0 (508) 25.0 (635) 30.0 (762)<br />

5000 4000 25.0 (635) 30.0 (762) 30.0 (762)<br />

Notes: X1 is the Intial Amperage Stub. X2 is the Reduced Amperage Stub.<br />

IF X2 = 3200A or 4000A, the Box height will need to be increased from 20.00" to<br />

24.00" due to the 3500A+ Fuses have a diameter of 5.75"<br />

180 Degrees Phase Rotation<br />

Fittings, Dimensions (std/min.)<br />

Ampere Rating<br />

AL L-Rated<br />

Dimensions A<br />

Inches (mm)<br />

225 — 7.9 (200)<br />

400 — 7.9 (200)<br />

600 — 7.9 (200)<br />

800 400 8.5 (216)<br />

1000 600 9.4 (239)<br />

1200 800 10.5 (267)<br />

1350 1000 11.5 (293)<br />

1600 1200 12.6 (321)<br />

2000 1350, 1600 14.9 (376)<br />

2500 2000 17.6 (447)<br />

3000 2500 19.8 (503)<br />

3200 2000 21.3 (541)<br />

4000 3000, 3200 24.3 (617)<br />

CU M-Rated<br />

225 — 7.9 (200)<br />

400 — 7.9 (200)<br />

600 — 7.9 (200)<br />

800 400 7.9 (200)<br />

1000 — 8.4 (213)<br />

1200 600 9.0 (229)<br />

1350 800 9.6 (245)<br />

1600 1000 10.6 (270)<br />

2000 1200, 1350 12.1 (372)<br />

— 1600 12.6 (321)<br />

2500 2000 14.6 (200)<br />

3000 — 15.8 (402)<br />

3200 — 17.3 (439)<br />

4000<br />

2500, 3000,<br />

3200<br />

19.3 (490)<br />

5000 4000 23.3 (592)<br />

Fused Reducers<br />

The National Electric Code requires over current protection when<br />

busway systems are reduced in ampacity. A fused reducer is used to<br />

reduce the allowable ampere rating in those sections of the busway<br />

that do not require a higher rating (i.e. at branch circuit junctures).<br />

Fused Reducer – Class L Size Fuses<br />

Suffix RFRF<br />

90 Degrees Phase Rotation<br />

Fittings, Dimensions (std/min.)<br />

Ampere Rating Dimensions A<br />

AL L-Rated Inches (mm)<br />

225<br />

400<br />

600<br />

800<br />

225<br />

400 17 (432)<br />

1000 600<br />

1200 800<br />

1350 1000<br />

1600 1200<br />

2000 1350, 1600<br />

20 (508)<br />

2500 2000 24 (610)<br />

3000 2500 28 (711)<br />

3200 —<br />

4000 3000<br />

34 (863)<br />

CU M-Rated<br />

225<br />

400<br />

600<br />

225 & 400<br />

800<br />

1000 —<br />

17 (432)<br />

1200 600<br />

1350 800<br />

1600 1000<br />

2000 1200, 1350<br />

— 1600 20 (508)<br />

2500 2000<br />

3000 — 24 (610)<br />

3200 —<br />

4000<br />

2500, 28 (711)<br />

3000<br />

5000 4000 34 (863)<br />

Non-Fused Reducers<br />

Non-fused reducers are used in conjunction with the following<br />

exception to the Fused Reducer in the National Electric Code:<br />

“For industrial establishments only, omission of over current<br />

protection shall be permitted at points where busways are reduced<br />

in ampacity, provided that the length of the busway having the<br />

smaller ampacity does not exceed 50 ft. and has an ampacity of<br />

at least equal to one-third the rating or setting of the over current<br />

device next back on the line, and provided that such busway is<br />

free from contact with combustible material.” Special joint stack<br />

connections are provided for non-fused reducer connections.<br />

Consult factory for specific design guidelines.<br />

Phase-Rotation Fittings<br />

Phase-rotation fittings can be used when the application<br />

requires a phase rotation in the power supply. Phase<br />

rotation fittings can be ordered for “phase and<br />

ground”, “phase only” and “ground only” rotations.<br />

Phase Rotation Fitting<br />

Suffix TRPG, Phase and Ground<br />

TRPO, Phase Only<br />

TRGO, Ground Only<br />

90 Degrees Phase<br />

Rotation Fitting<br />

180 Degrees Phase<br />

Rotation Fitting<br />

15<br />

BUSWAY SYSTEMS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-23


Sentron Busway Systems<br />

Service Heads<br />

Selection<br />

Service Heads are used to connect busway to a service entrance. In the Sentron Busway line, 3 single-phase service heads and<br />

3-phase service head connections are available. The standard service entrance connection is the 3-phase service head which<br />

consists of one service head for all three phases. 3 single-phase service heads consist of three heads – one for each phase and<br />

may be used to meet the requirements of certain applications. To ensure ease of installation of incoming cables, both types of<br />

Sentron service heads are constructed so that the lugs face the Glastic bottom of the box. The Glastic bottom provides<br />

insulation and protection to the incoming cables.<br />

15<br />

BUSWAY SYSTEMS<br />

Single-Phase Service Heads, Dimensions (standard/min.)<br />

Cable Lugs per<br />

Dimensions Inches (mm) Phase and Neutral Ground<br />

Ampere Rating Single-Phase “A” Qty. Size Lugs a<br />

AL L-Rated<br />

225 13 (330) 1 a 1<br />

400 225 13 (330) 1 b 1<br />

600 — 13 (330) 2 b 1<br />

800 400 13 (330) 3 b 1<br />

1000 600 13 (330) 4 b 1<br />

1200 800 18 (457) 4 b 1<br />

1350 1000 18 (457) 4 b 1<br />

1600 1200 18 (457) 5 b 1<br />

2000 1350,1600 20 (508) 6 b 2<br />

2500 2000 27 (686) 8 b 2<br />

3000 2500 29 (737) 9 b 2<br />

3200 2000 29 (737) 9 b 2<br />

4000 3000,3200 29 (737) 12 b 3<br />

CU M-Rated<br />

225 13 (330) 1 a 1<br />

400 13 (330) 1 b 1<br />

600 13 (330) 2 b 1<br />

800 400 13 (330) 3 b 1<br />

1000 — 13 (330) 4 b 1<br />

1200 600 13 (330) 4 b 1<br />

1350 800 13 (330) 4 b 1<br />

1600 1000 18 (457) 5 b 1<br />

2000 1200,1350 20 (508) 6 b 2<br />

— 1600 18 (457) 5 b 1<br />

2500 2000 20 (508) 8 b 2<br />

3000 — 27 (686) 9 b 2<br />

3200 — 27 (686) 9 b 2<br />

4000 2500,3000,3200 27 (686) 12 b 3<br />

5000 4000 29 (737) 15 b 4<br />

Three Single-Phase Service Heads<br />

Suffix V1TX<br />

Three-Phase Service Heads, Dimensions (standard/min.)<br />

Cable Lugs per<br />

Dimensions Inches (mm) Phase and Neutral Ground<br />

Ampere Rating Three-Phase “B” Qty. Size Lugs a<br />

AL L-Rated<br />

225 13 (330) 1 a 1<br />

400 225 13 (330) 1 b 1<br />

600 — 13 (330) 2 b 1<br />

800 400 13 (330) 3 b 1<br />

1000 600 13 (330) 4 b 1<br />

1200 800 18 (457) 4 b 1<br />

1350 1000 18 (457) 4 b 1<br />

1600 1200 18 (457) 5 b 1<br />

2000 1350,1600 18 (457) 6 b 2<br />

2500 2000 27 (686) 8 b 2<br />

3000 2500 27 (686) 9 b 2<br />

3200 2000 27 (686) 9 b 2<br />

4000 3000,3200 29 (737) 12 b 3<br />

CU M-Rated<br />

225 13 (330) 1 a 1<br />

400 13 (330) 1 b 1<br />

600 13 (330) 2 b 1<br />

800 400 13 (330) 3 b 1<br />

1000 — 13 (330) 4 b 1<br />

1200 600 13 (330) 4 b 1<br />

1350 800 13 (330) 4 b 1<br />

1600 1000 18 (457) 5 b 1<br />

2000 1200,1350 18 (457) 6 b 2<br />

— 1600 18 (457) 5 b 1<br />

2500 2000 18 (457) 8 b 2<br />

3000 — 27 (686) 9 b 2<br />

3200 — 27 (686) 9 b 2<br />

4000 2500,3000,3200 27 (686) 12 b 3<br />

5000 4000 29 (737) 15 b 4<br />

Three-Phase Service Head<br />

Suffix V3TX<br />

a #6 AWG - 350 kcmil, Cu / Al.<br />

b #4 AWG - 600 kcmil, Cu / Al.<br />

15-24<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron Busway Systems<br />

Hangers<br />

Revised on 06/30/18<br />

Selection<br />

Trapeze Hanger—Aluminum (AL) and Copper (CU)<br />

“A” Dimensions Flat Mounted<br />

Ampere Rating<br />

Inches (mm) Catalog Number a<br />

AL L-Rated<br />

225 — 10.0 (254) SXTH1<br />

400 — 10.0 (254) SXTH1<br />

600 — 10.0 (254) SXTH1<br />

800 400 10.0 (254) SXTH1<br />

1000 600 10.0 (254) SXTH1<br />

1200 800 10.0 (254) SXTH1<br />

1350 1000 13.5 (343) SXTH2<br />

1600 1200 13.5 (343) SXTH2<br />

2000 1350,1600 13.5 (343) SXTH2<br />

2500 2000 13.5 (343) SXTH3<br />

3000 2500 13.5 (343) SXTH3<br />

3200 2000 13.5 (343) SXTH3<br />

4000 3000,3200 23.0 (584) SXTH4<br />

CU M-Rated<br />

225 — 10.0 (254) SXTH1<br />

400 — 10.0 (254) SXTH1<br />

600 — 10.0 (254) SXTH1<br />

800 400 10.0 (254) SXTH1<br />

1000 — 10.0 (254) SXTH1<br />

1200 600 10.0 (254) SXTH1<br />

1350 800 10.0 (254) SXTH1<br />

1600 1000 10.0 (254) SXTH1<br />

2000 1200,1350 13.5 (343) SXTH2<br />

— 1600 13.5 (343) SXTH2<br />

2500 2000 13.5 (343) SXTH2<br />

3000 — 18.5 (470) SXTH3<br />

3200 — 18.5 (470) SXTH3<br />

4000 2500,3000,3200 18.5 (470) SXTH3<br />

5000 4000 23.0 (584) SXTH4<br />

a Use SXTH1 for Edge Mounted.<br />

Spring Hanger—Aluminum (AL) and Copper (CU) b<br />

Ampere Rating<br />

Floor to Ceiling Height (ft.)<br />

10 12 14 16 18<br />

AL L-Rated<br />

225 — SXSH4 SXSH4 SXSH4 SXSH4 SXSH4<br />

400 — SXSH4 SXSH4 SXSH4 SXSH4 SXSH4<br />

600 — SXSH4 SXSH4 SXSH4 SXSH4 SXSH4<br />

800 400 SXSH4 SXSH4 SXSH4 SXSH6 SXSH6<br />

1000 600 SXSH4 SXSH4 SXSH4 SXSH6 SXSH6<br />

1200 800 SXSH4 SXSH4 SXSH4 SXSH6 SXSH6<br />

1350 1000 SXSH4 SXSH4 SXSH6 SXSH6 SXSH6<br />

1600 1200 SXSH8 SXSH8 SXSH8 SXSH8 SXSH8<br />

2000 1350,1600 SXSH8 SXSH8 SXSH8 SXSH8 SXSH8<br />

2500 2000 SXSH8 SXSH8 SXSH8 SXSH10 SXSH10<br />

3000 2500 SXSH8 SXSH8 SXSH10 SXSH10 SXSH10<br />

3200 2000 SXSH8 SXSH8 SXSH10 SXSH10 SXSH10<br />

4000 3000,3200 SXSH8 SXSH10 SXSH10 SXSH10 SXSH12<br />

CU M-Rated<br />

Trapeze Hanger<br />

A complete offering of hangers is available to<br />

support Sentron Busway in both vertical and<br />

horizontal applications. Standard trapeze hangers<br />

support Sentron Busway in horizontal applications<br />

on 10 ft. (3.05m) centers. Additional hangers may<br />

be used if structural requirements mandate their<br />

use. The contractor must supply drop rods to<br />

complete assembly for trapeze hangers.<br />

Flat<br />

Mounted<br />

Edge<br />

Mounted<br />

Watch the<br />

Busway<br />

Support<br />

installation<br />

video<br />

Spring Hanger<br />

Spring hangers and floor support hangers must<br />

be used to provide secure mounting of the<br />

busway run in vertical applications. Spring<br />

hangers support the weight of the busway on<br />

each floor and also compensate for minimal<br />

building movement and thermal expansion.<br />

Maximum distance between spring hangers<br />

may not exceed 16 ft. (4.88m). When ordering<br />

18 ft. (5.49m) floor to ceiling height assemblies,<br />

intermediate support hangers are necessary.<br />

15<br />

BUSWAY SYSTEMS<br />

225 — SXSH4 SXSH4 SXSH4 SXSH4 SXSH4<br />

400 — SXSH4 SXSH4 SXSH4 SXSH4 SXSH4<br />

600 — SXSH4 SXSH4 SXSH4 SXSH4 SXSH4<br />

800 400 SXSH4 SXSH4 SXSH6 SXSH6 SXSH6<br />

1000 — SXSH4 SXSH6 SXSH6 SXSH6 SXSH8<br />

1200 600 SXSH6 SXSH6 SXSH6 SXSH8 SXSH8<br />

1350 800 SXSH6 SXSH6 SXSH6 SXSH8 SXSH8<br />

1600 1000 SXSH8 SXSH8 SXSH10 SXSH10 SXSH10<br />

2000 1200,1350 SXSH8 SXSH10 SXSH10 SXSH10 SXSH12<br />

2500 2000 SXSH10 SXSH12 SXSH12 SXSH12 SXSH14<br />

3000 — SXSH10 SXSH12 SXSH12 SXSH14 SXSH14<br />

3200 — SXSH12 SXSH12 SXSH14 SXSH14 SXSH12A<br />

4000<br />

2500,<br />

3000, 3200<br />

SXSH12 SXSH14 SXSH14 SXSH16 SXSH14A<br />

5000 4000 SXSH14 SXSH12A SXSH14A SXSH16A SXSH16B<br />

b Assuming 3P4W busway with no additional busway-supported weight per floor. This information is confirmed<br />

during the quotation process, for additional information please contact your local Siemens Sales representative.<br />

*Note: Flanges do not offer support to the busway. Flanges provide<br />

a means of covering the hole created in the existing structure.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-25


Sentron Busway Systems<br />

Hangers<br />

Selection<br />

15<br />

BUSWAY SYSTEMS<br />

Structural Steel Hanger, Dimensions and Catalog Numbers<br />

“A” Dimensions Catalog<br />

Ampere Rating Inches (mm) Number<br />

AL L-Rated<br />

225 — 10.0 (254) SXSS1<br />

400 — 10.0 (254) SXSS1<br />

600 — 10.0 (254) SXSS1<br />

800 400 10.0 (254) SXSS1<br />

1000 600 10.0 (254) SXSS1<br />

1200 800 10.0 (254) SXSS1<br />

1350 1000 13.5 (343) SXSS2<br />

1600 1200 13.5 (343) SXSS2<br />

2000 1350,1600 13.5 (343) SXSS2<br />

2500 2000 18.5 (470) SXSS3<br />

3000 2500 18.5 (470) SXSS3<br />

3200 2000 18.5 (470) SXSS3<br />

4000 3000,3200 23.0 (584) SXSS4<br />

CU M-Rated<br />

225 — 10.0 (254) SXSS1<br />

400 — 10.0 (254) SXSS1<br />

600 — 10.0 (254) SXSS1<br />

800 400 10.0 (254) SXSS1<br />

1000 — 10.0 (254) SXSS1<br />

1200 600 10.0 (254) SXSS1<br />

1350 800 10.0 (254) SXSS1<br />

1600 1000 10.0 (254) SXSS1<br />

2000 1200,1350 13.5 (343) SXSS2<br />

— 1600 13.5 (343) SXSS2<br />

2500 2000 13.5 (343) SXSS2<br />

3000 — 13.5 (343) SXSS2<br />

3200 — 13.5 (343) SXSS2<br />

4000 2500,3000,3200 13.5 (343) SXSS2<br />

5000 4000 23.0 (584) SXSS4<br />

Single Drop Rod Hanger, Catalog Numbers<br />

Ampere Rating<br />

Catalog Number<br />

AL L-Rated<br />

225 — SXDRA1<br />

400 — SXDRA1<br />

600 — SXDRA1<br />

800 400 SXDRA2<br />

1000 600 SXDRA3<br />

1200 800 SXDRA4<br />

1350 1000 SXDRA5<br />

1600 1200 SXDRA6<br />

2000 1350,1600 SXDRA7<br />

2500 2000 —<br />

3000 2500 —<br />

3200 2000 —<br />

4000 3000,3200 —<br />

CU M-Rated<br />

225 — SXDRC1<br />

400 — SXDRC1<br />

600 — SXDRC1<br />

800 400 SXDRC1<br />

1000 — SXDRC2<br />

1200 600 SXDRC3<br />

1350 800 SXDRC4<br />

1600 1000 SXDRC5<br />

2000 1200,1350 SXDRC6<br />

— 1600 SXDRC6<br />

2500 2000 SXDRC7<br />

3000 — —<br />

3200 — —<br />

4000 2500,3000,3200 —<br />

5000 4000 —<br />

Structural Steel Hanger<br />

A complete offering of hangers is available to support Sentron Busway in<br />

both vertical and horizontal applications. Structural Steel hangers support<br />

Sentron Busway in horizontal applications on 10 ft. (3.05m) centers.<br />

Additional hangers may be used if structural requirements mandate their<br />

use.<br />

Single Drop Rod Hanger<br />

A complete offering of hangers is available to support Sentron Busway in<br />

both vertical and horizontal applications. Single drop rod hangers support<br />

Sentron Busway in horizontal applications on 10 ft. (3.05m) centers.<br />

Additional hangers may be used if structural requirements mandate their<br />

use. The contractor must supply drop rods to complete assembly for single<br />

drop rod hangers.<br />

Note: Drop rod hangers can only be used when<br />

phase arrows are pointing up.<br />

15-26<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron Busway Systems<br />

Hangers and End Closers<br />

Selection<br />

Wall Mounted Hanger, Dimensions and Catalog Numbers<br />

Dimensions Inches (mm) Catalog<br />

Ampere Rating “A” ”B” ”C” Number<br />

AL L-Rated<br />

225 — 12.3 (311) 6.1 (156) 4.2 (107) SXWH1<br />

400 — 12.3 (311) 6.1 (156) 4.2 (107) SXWH1<br />

600 — 12.3 (311) 6.1 (156) 4.2 (107) SXWH1<br />

800 400 12.3 (311) 6.1 (156) 3.8 (97) SXWH1<br />

1000 600 12.3 (311) 6.1 (156) 3.8 (97) SXWH1<br />

1200 800 12.3 (311) 6.1 (156) 2.8 (72) SXWH1<br />

1350 1000 16.3 (413) 8.1 (206) 4.4 (111) SXWH2<br />

1600 1200 16.3 (413) 8.1 (206) 3.9 (98) SXWH2<br />

2000 1350,1600 16.3 (413) 8.1 (206) 2.8 (70) SXWH2<br />

2500 2000 20.8 (527) 10.4 (264) 3.6 (92) SXWH3<br />

3000 2500 20.8 (527) 10.4 (264) 2.5 (64) SXWH3<br />

3200 2000 20.8 (527) 10.4 (264) 1.8 (46) SXWH3<br />

4000 3000,3200 25.3 (641) 12.6 (321) 2.5 (64) SXWH4<br />

CU M-Rated<br />

225 — 12.3 (311) 6.1 (156) 4.2 (107) SXWH1<br />

400 — 12.3 (311) 6.1 (156) 4.2 (107) SXWH1<br />

600 — 12.3 (311) 6.1 (156) 4.2 (107) SXWH1<br />

800 400 12.3 (311) 6.1 (156) 3.8 (97) SXWH1<br />

1000 — 12.3 (311) 6.1 (156) 3.8 (97) SXWH1<br />

1200 600 12.3 (311) 6.1 (156) 2.8 (72) SXWH1<br />

1350 800 12.3 (311) 6.1 (156) 2.8 (72) SXWH1<br />

1600 1000 12.3 (311) 6.1 (156) 2.8 (72) SXWH1<br />

2000 1200,1350 16.3 (413) 8.1 (206) 4.4 (111) SXWH2<br />

— 1600 16.3 (413) 8.1 (206) 3.9 (98) SXWH2<br />

2500 2000 16.3 (413) 8.1 (206) 2.8 (70) SXWH2<br />

3000 — 20.8 (527) 10.4 (264) 3.6 (92) SXWH3<br />

3200 — 20.8 (527) 10.4 (264) 2.5 (64) SXWH3<br />

4000 2500,3000,3200 20.8 (527) 10.4 (264) 1.8 (46) SXWH3<br />

5000 4000 25.3 (641) 12.6 (321) 2.5 (64) SXWH4<br />

Wall Mounted Hanger<br />

Wall Mounted Hangers are used for horizontal<br />

applications close to a wall. The busway can be mounted<br />

either edgewise or flatwise to the wall.<br />

Wall Mounted Hanger ensures the minimum clearance<br />

between the wall and the busway run.<br />

End Closers<br />

End closers safely terminate a busway run and protect the<br />

bus bar ends. End closers may be removed easily in order<br />

to extend a busway run. End closers are shipped with<br />

Glastic insulation pieces, however, joint stacks and<br />

inspection covers are not included.<br />

End Closers<br />

(Joint stack and covers not included)<br />

Suffix ECLS<br />

15<br />

BUSWAY SYSTEMS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-27


Sentron Busway Systems<br />

Roof, Wall, Ceiling and Floor Flanges<br />

Selection<br />

Roof, wall, ceiling and floor flanges are available for Sentron<br />

Busway. When the busway run passes thorough a roof, wall or<br />

ceiling, a flange should be used. Flanges do not offer support<br />

to the busway. Flanges provide a means of covering the hole<br />

created in the existing structure. Additional sealant may be<br />

required to meet fire codes and all other local requirements. No<br />

caulking or gasketing is provided with Sentron flanges.<br />

15<br />

BUSWAY SYSTEMS<br />

Roof Flanges, Dimensions<br />

Dimensions Inches (mm)<br />

Ampere Rating “A” ”B”<br />

AL L-Rated<br />

225 — 12 (305) 18 (457)<br />

400 — 12 (305) 18 (457)<br />

600 — 12 (305) 18 (457)<br />

800 400 12 (305) 18 (457)<br />

1000 600 12 (305) 18 (457)<br />

1200 800 12 (305) 18 (457)<br />

1350 1000 16 (406) 22 (559)<br />

1600 1200 16 (406) 22 (559)<br />

2000 1350,1600 16 (406) 22 (559)<br />

2500 2000 20.5 (521) 22 (559)<br />

3000 2500 20.5 (521) 26.5 (673)<br />

3200 2000 20.5 (521) 26.5 (673)<br />

4000 3000,3200 25 (635) 31 (787)<br />

CU M-Rated<br />

225 — 12 (305) 18 (457)<br />

400 — 12 (305) 18 (457)<br />

600 — 12 (305) 18 (457)<br />

800 400 12 (305) 18 (457)<br />

1000 — 12 (305) 18 (457))<br />

1200 600 12 (305) 18 (457)<br />

1350 800 12 (305) 18 (457)<br />

1600 1000 12 (305) 18 (457)<br />

2000 1200,1350 16 (406) 22 (559)<br />

— 1600 16 (406) 22 (559)<br />

2500 2000 16 (406) 22 (559)<br />

3000 — 20.5 (521) 26.5 (673)<br />

3200 — 20.5 (521) 26.5 (673)<br />

4000 2500,3000,3200 20.5 (521) 26.5 (673)<br />

5000 4000 25 (635) 31 (787)<br />

Roof Flanges<br />

Roof flanges are available for Sentron Busway. When the busway run passes<br />

thorough a roof, a flange should be used. Flanges do not offer support to the<br />

busway. Flanges provide a means of covering the hole created in the existing<br />

structure. Additional sealant may be required to meet fire codes and all other<br />

local requirements. No caulking or gasketing is provided with Sentron flanges.<br />

Roof flanges provide a watertight seal for use with NEMA 3R and IP66 rated<br />

busway. Roof pitch must be indicated on drawings when ordering roof flanges.<br />

Roof Flanges<br />

Suffix GRFL<br />

Wall, Ceiling and Floor Flanges, Dimensions<br />

Dimensions Inches (mm)<br />

Ampere Rating “A” ”B”<br />

AL L-Rated<br />

225 — 11 (279) 7 (178)<br />

400 — 11 (279) 7 (178)<br />

600 — 11 (279) 7 (178)<br />

800 400 11 (279) 7 (178)<br />

1000 600 12 (305) 8 (203)<br />

1200 800 13 (330) 9 (229)<br />

1350 1000 14 (356) 10 (254)<br />

1600 1200 15 (381) 11 (279)<br />

2000 1350,1600 17 (432) 13 (330)<br />

2500 2000 20 (508) 16 (406)<br />

3000 2500 22 (559) 18 (457)<br />

3200 2000 24 (610) 20 (508)<br />

4000 3000,3200 26 (660) 22 (559)<br />

CU M-Rated<br />

225 — 10 (254) 6 (152)<br />

400 — 10 (254) 6 (152)<br />

600 — 10 (254) 6 (152)<br />

800 400 10 (254) 6 (152)<br />

1000 — 11 (279) 7 (178)<br />

1200 600 12 (305) 8 (203)<br />

1350 800 12 (305) 8 (203)<br />

1600 1000 13 (330) 9 (229)<br />

2000 1200,1350 15 (381) 11 (279)<br />

— 1600 15 (381) 11 (279)<br />

2500 2000 17 (432) 13 (330)<br />

3000 — 18 (457) 14 (356)<br />

3200 — 19 (483) 15 (381)<br />

4000 2500,3000,3200 21 (533) 17 (432)<br />

5000 4000 26 (660) 22 (559)<br />

Wall, Ceiling and Floor Flanges<br />

Wall/Floor flanges are available for Sentron Busway. When the busway run<br />

passes thorough a wall, ceiling or floor, a flange should be used. Flanges do<br />

not offer support to the busway. Flanges provide a means of covering the hole<br />

created in the existing structure. Additional sealant may be required to meet<br />

fire codes and all other local requirements. No caulking or gasketing is<br />

provided with Sentron flanges.<br />

Wall, Ceiling and Floor Flanges<br />

Suffix GWFL<br />

15-28<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron Busway Systems<br />

Busway Accessories<br />

Revised on 04/30/18<br />

Selection<br />

The following table identifies the approximate feeder footage that is included in busway fittings.<br />

Ampere<br />

Rating<br />

225–1350 Al<br />

225–1600 Cu<br />

1600–3200 Al<br />

2000–4000 Cu<br />

4000 Al<br />

5000 Cu<br />

Elbow<br />

Stack Elbow Tee Cross<br />

Tap<br />

Box<br />

End<br />

Tap<br />

Box<br />

Center<br />

Flanged<br />

End<br />

Swbd.<br />

Conn.<br />

XFMR<br />

Throat<br />

Expansion<br />

Section<br />

Reducer<br />

Fusible<br />

0' 2' 3' 4' 1' 4' 1' 4' 4' 4' 4'<br />

0' 3' 5' 6' 1' 4' 1' 4' 4' 4' 4'<br />

0' 4' 6' 8' 1' 4' 1' 4' 4' 4' 4'<br />

Reducer<br />

Unfused<br />

Watch<br />

the Joint<br />

Assembly<br />

video<br />

“M” Rating / Standard<br />

Rating Conversion Table<br />

1000/A Square Inch<br />

“M” Rating<br />

Standard Rating Equivalent<br />

Sentron<br />

225 600<br />

400 800<br />

600 1200<br />

800 1350<br />

1000 1600<br />

1200 2000<br />

1350 2000<br />

1600 —<br />

2000 2500<br />

2500 4000<br />

3000 4000<br />

3200 4000<br />

4000 5000<br />

Sway Brace Bracket<br />

Catalog Number SXSB<br />

“L" Rating / Standard<br />

Rating Conversion Table<br />

750/A Square Inch<br />

“L” Rating<br />

Standard Rating Equivalent<br />

Sentron<br />

225 600<br />

400 800<br />

600 1000<br />

800 1200<br />

1000 1350<br />

1200 1600<br />

1350 2000<br />

1600 2000<br />

2000 2500<br />

2500 3000<br />

3000 4000<br />

3200 4000<br />

Lifting Kit<br />

Catalog Number SXLK<br />

15<br />

BUSWAY SYSTEMS<br />

Busway Assembly Tool<br />

Catalog Number SXBAT<br />

Product Category: BUSW<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-29


Sentron Busway Systems<br />

Flanged Ends<br />

Flanged ends provide a direct connection to low-voltage<br />

switchgear, switchboards, motor control centers, large<br />

power panels, and other electrical distribution equipment.<br />

Selection<br />

Flanged ends are shipped with one joint stack assembly. The<br />

switchgear manufacture supplies lugs and mounting hardware.<br />

See illustration for flanged end drilling patterns.<br />

15<br />

BUSWAY SYSTEMS<br />

Flanged End, Dimensions<br />

Dimensions Inches (mm)<br />

Fig.<br />

Ampere Rating “W” No.<br />

AL L-Rated<br />

225 — 1.75 (44.4) 1<br />

400 — 1.75 (44.4) 1<br />

600 — 1.75 (44.4) 1<br />

800 400 2.38 (60.5) 1<br />

1000 600 3.25 (82.6) 1<br />

1200 800 4.38 (111.3) 1<br />

1350 1000 5.38 (136.7) 1<br />

1600 1200 6.50 (165.1) 1<br />

2000 1350,1600 8.75 (222.3) 1<br />

2500 2000 5.63 (143.0) 2<br />

3000 2500 6.75 (171.5) 2<br />

3200 2000 6.75 (171.5) 2<br />

4000 3000,3200 9.00 (228.6) 2<br />

CU M-Rated<br />

225 — 1.75 (44.4) 1<br />

400 — 1.75 (44.4) 1<br />

600 — 1.75 (44.4) 1<br />

800 400 1.75 (44.4) 1<br />

1000 — 2.25 (57.2) 1<br />

1200 600 2.88 (73.2) 1<br />

1350 800 3.50 (88.9) 1<br />

1600 1000 4.50 (114.3) 1<br />

2000 1200,1350 6.00 (152.4) 1<br />

— 1600 6.50 (165.1) 1<br />

2500 2000 8.50 (215.9) 1<br />

3000 — 4.75 (120.7) 2<br />

3200 — 5.50 (139.7) 2<br />

4000 2500,3000,3200 6.50 (165.1) 2<br />

5000 4000 8.50 (215.9) 2<br />

Flanged End<br />

Suffix FRND<br />

Figure 1 Figure 2<br />

b<br />

Flanged End Bus Bar Drilling Pattern (NEMA) a<br />

(Same pattern for 2 bus bars per pole, see figure 2 above.)<br />

a Other drilling patterns are available and must be specified at order entry.<br />

b See Figures 4, 5 and 6 on page 15-32.<br />

15-30<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron Busway Systems<br />

Flanged Ends<br />

Revised on 04/30/18<br />

Selection<br />

Flanged End, Dimensions (standard/min.)<br />

Dimensions Inches (mm)<br />

Ampere Rating Ref. Bar Width Fig. No. “A” ”B” ”C” ”D” ”E” ”F” ”G” Fig. No.<br />

AL L-Rated<br />

225 — 2.38 (60.5) 1 10.0 (254) 8.00 (203) 4.38 (111) 1.94 (49) 3.88 (99) — 6.00 (152) 4, 5<br />

400 — 2.38 (60.5) 1 10.0 (254) 8.00 (203) 4.38 (111) 1.94 (49) 3.88 (99) — 6.00 (152) 4, 5<br />

600 — 2.38 (60.5) 1 10.0 (254) 8.00 (203) 4.38 (111) 1.94 (49) 3.88 (99) — 6.00 (152) 4, 5<br />

800 400 2.38 (60.5) 1 10.0 (254) 8.00 (203) 4.38 (111) 1.94 (49) 3.88 (99) — 6.00 (152) 4, 5<br />

1000 600 3.25 (82.6) 1 10.0 (254) 8.00 (203) 4.38 (111) 1.94 (49) 2.06 (52) — 6.00 (152) 4, 6<br />

1200 800 4.38 (111.3) 2 15.50 (395) 13.50 (343) 7.13 (181) 1.60 (41) 3.19 (81) — 8.50 (216) 4, 6<br />

1350 1000 5.38 (136.7) 2 15.50 (395) 13.50 (343) 7.13 (181) 2.10 (53) 4.19 (106) — 8.50 (216) 4, 6<br />

1600 1200 6.50 (165.1) 2 15.50 (395) 13.50 (343) 7.13 (181) 2.66 (67) 5.31 (135) — 8.50 (216) 4, 6<br />

2000 1350,1600 8.75 (222.3) 2 15.50 (395) 13.50 (343) 7.13 (181) 3.78 (96) 7.56 (192) — 8.50 (216) 4, 6<br />

2500 2000 5.63 (143.0) 3 20.0 (508) 18.00 (457) 4.50 (114) 0.68 (17) 1.37 (36) 4.44 (113) 13.25 (337) 4, 6<br />

3000 2500 6.75 (171.5) 3 20.0 (508) 18.00 (457) 4.50 (114) 0.68 (17) 1.37 (36) 5.56 (141) 13.25 (337) 4, 6<br />

3200 2000 7.50 (190.5) 4 24.0 (610) 22.0 (569) 5.50 (140) 0.68 (17) 1.37 (36) 6.32 (161) 13.25 (337) 4, 6<br />

4000 3000,3200 9.00 (228.6) 4 24.0 (610) 22.0 (569) 5.50 (140) 0.68 (17) 1.37 (36) 7.81 (198) 14.25 (362) 4, 6<br />

CU M-Rated<br />

225 — 1.75 (44.4) 1 10.0 (254) 8.00 (203) 4.38 (111) 1.63 (41) 3.25 (83) — 6.00 (152) 4, 5<br />

400 — 1.75 (44.4) 1 10.0 (254) 8.00 (203) 4.38 (111) 1.63 (41) 3.25 (83) — 6.00 (152) 4, 5<br />

600 — 1.75 (44.4) 1 10.0 (254) 8.00 (203) 4.38 (111) 1.63 (41) 3.25 (83) — 6.00 (152) 4, 5<br />

800 400 1.75 (44.4) 1 10.0 (254) 8.00 (203) 4.38 (111) 1.63 (41) 3.25 (83) — 6.00 (152) 4, 5<br />

1000 — 2.25 (57.2) 1 10.0 (254) 8.00 (203) 4.38 (111) 1.88 (48) 3.75 (95) — 6.00 (152) 4, 5<br />

1200 600 2.88 (73.2) 1 10.0 (254) 8.00 (203) 4.38 (111) 0.85 (21) 1.69 (43) — 6.00 (152) 4, 6<br />

1350 800 3.50 (88.9) 1 10.0 (254) 8.00 (203) 4.38 (111) 1.16 (29) 2.31 (59) — 6.00 (152) 4, 6<br />

1600 1000 4.50 (114.3) 2 15.50 (395) 13.50 (343) 7.13 (181) 1.66 (42) 3.31 (84) — 8.50 (216) 4, 6<br />

2000 1200,1350 6.00 (152.4) 2 15.50 (395) 13.50 (343) 7.13 (181) 2.41 (42) 4.81 (122) — 8.50 (216) 4, 6<br />

— 1600 6.50 (165.1) 2 15.50 (395) 13.50 (343) 7.13 (181) 2.66 (67) 5.31 (135) — 8.50 (216) 4, 6<br />

2500 2000 8.50 (215.9) 2 15.50 (395) 13.50 (343) 7.13 (181) 3.66 (93) 7.31 (186) — 8.50 (216) 4, 6<br />

3000 — 4.75 (120.7) 3 20.0 (508) 18.00 (457) 4.50 (114) 0.68 (17) 1.37 (36) 3.56 (90) 13.25 (337) 4, 6<br />

3200 — 5.50 (139.7) 3 20.0 (508) 18.00 (457) 4.50 (114) 0.68 (17) 1.37 (36) 4.32 (110) 13.25 (337) 4, 6<br />

4000 2500,3000,3200 6.50 (165.1) 3 20.0 (508) 18.00 (457) 4.50 (114) 0.68 (17) 1.37 (36) 5.31 (135) 13.25 (337) 4, 6<br />

5000 4000 8.50 (215.9) 4 24.0 (610) 22.00 (569) 5.50 (140) 0.68 (17) 1.37 (36) 7.31 (186) 14.25 (362) 4, 6<br />

Figure 1 Figure 2<br />

Figure 3<br />

15<br />

BUSWAY SYSTEMS<br />

Integral and Internal Ground Strap Drilling Detail<br />

Figure 4 Figure 5 Figure 6<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-31


Sentron Busway Systems<br />

Combination Flange/Elbows<br />

Revised on 06/30/18<br />

Selection<br />

Combination Flange/Elbow<br />

A combination Flange/Elbow may be used in space<br />

constrained applications. Flatwise and edgewise combination<br />

flange/elbows require a minimum clearance of 5 in. (127mm)<br />

from the top of the connecting equipment to the centerline of<br />

the busway.<br />

Flat Elbow with Flanged End, Dimensions<br />

15<br />

BUSWAY SYSTEMS<br />

Ampere Dimensions inches (mm)<br />

Rating Minimum Maximum Minimum Maximum<br />

"A" "B" "A" "B" "A" "B" "A" "B"<br />

800 4.75 (121) 12 (305) 22 (559) 48 (1219) 4.50 (121) 12 (305) 22 (559) 48 (1219)<br />

1000 5.20 (132) 12 (305) 22 (559) 48 (1219) 4.70 (121) 12 (305) 22 (559) 48 (1219)<br />

1200 5.75 (146) 12 (305) 22 (559) 48 (1219) 5.00 (121) 12 (305) 22 (559) 48 (1219)<br />

1350 6.25 (159) 12 (305) 22 (559) 48 (1219) 5.30 (121) 12 (305) 22 (559) 48 (1219)<br />

1600 6.80 (173) 18 (457) 22 (559) 48 (1219) 5.80 (121) 12 (305) 22 (559) 48 (1219)<br />

2000 8.00 (203) 18 (457) 28 (711) 48 (1219) 6.60 (121) 12 (305) 22 (559) 48 (1219)<br />

2500 9.30 (236) 18 (457) 28 (711) 48 (1219) 7.80 (121) 18 (457) 28 (711) 48 (1219)<br />

3000 10.40 (264) 18 (457) 28 (711) 48 (1219) 8.40 (121) 18 (457) 28 (711) 48 (1219)<br />

3200 11.15 (283) 18 (457) 28 (711) 48 (1219) 9.20 (234) 18 (457) 28 (711) 48 (1219)<br />

4000 12.70 (323) 24 (607) 34 (864) 48 (1219) 10.20 (121) 18 (457) 28 (711) 48 (1219)<br />

5000 12.20 (121) 24 (607) 34 (864) 48 (1219)<br />

Edge Elbow with Flanged End, Dimensions<br />

Minimum<br />

Maximum<br />

"A" "B" "A" "B"<br />

5.00 (127) 10 (254) 18 (457) 48 (1219)<br />

Edge Elbow with Flanged End<br />

Flat Elbow with Flanged End<br />

15-32<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron Busway Systems<br />

Cubicle Options<br />

Revised on 06/30/18<br />

Selection<br />

In-Line Disconnect Cubicle, Dimensions <br />

Description<br />

of Unit<br />

Type of Disconnect<br />

Fusible Switch 800-1200A Vacu-Break<br />

Molded Case JD6, LD6, MD6, ND6<br />

Circuit Breaker PD6, RD6<br />

Digital Sentron SJD6, SLD6, SMD6, SND6<br />

Series MCCB’s SPD6 1600A Frame<br />

Power<br />

200-5000A WL <br />

Circuit Breaker<br />

Bolted Pressure 800A<br />

Switch 1200-2500A<br />

3000A<br />

4000A<br />

ACCESScompatible<br />

In-Line Disconnect Cubicles<br />

Cubicles provide a means of mounting switches or circuit breakers where power<br />

feeds to or pulls from the busway system. When bolted connections are preferred,<br />

cubicles may be used in place of plug-in units. Cubicles can also be used at ampere<br />

ratings that exceed standard plug-in unit ratings. Modifications to cubicles can be<br />

made in order to accommodate key inter-locks, ground fault detector systems and<br />

power monitoring systems.<br />

In-Line Disconnect Cubicle<br />

Consult your local Siemens sales office for details on<br />

WL breakers.<br />

Consult factory for dimensions.<br />

Fusible Cubicles <br />

3-Pole, 600V/4-Pole, 480/277V<br />

Horizontal<br />

Vertical<br />

Ampere Ratings:<br />

800<br />

1200<br />

Bolted Pressure Switches <br />

3-Pole 480V, 4-Pole 480V,<br />

3-Pole 600V or 4-Pole 600V<br />

Ampere Ratings:<br />

800<br />

1200<br />

1600<br />

2000<br />

2500<br />

3000<br />

4000<br />

Solid State Molded Case Circuit<br />

Breaker Cubicles <br />

3-Pole, 600V or 4-Pole 480/277V<br />

Breaker Frame<br />

Ampere Rating<br />

SJD6-A, SHJD6-A,<br />

SCJD6-A<br />

200–400<br />

SLD6-A, SHLD6-A,<br />

SCLD6-A<br />

300–600<br />

SMD6, SHMD6,<br />

SCMD6-A<br />

600–800<br />

SND6, SHND6,<br />

SCND6-A<br />

800–1200<br />

SPD6, SHPD6 1400–1600<br />

a Fuses not included.<br />

For electrically operated, specify control voltage.<br />

IP40 and IP55<br />

Molded Case Circuit Breaker Cubicles<br />

3-Pole, 600V or 4-Pole 480/277V<br />

Breaker Type Ampere Rating<br />

FD6 70–250A<br />

JD6 200–400A<br />

LD6 450–600A<br />

MD6 500–800A<br />

ND6 900–1200A<br />

PD6 1200–1600A<br />

RD6 1600–2000A<br />

Power Circuit Breaker b<br />

3-Pole or 3-Phase, 4-Wire<br />

Breaker<br />

Frame<br />

Type<br />

Type WL<br />

Frame Size 1<br />

(S, H, L Rating Class)<br />

Frame Size 2<br />

(S, L, C Rating Class)<br />

Frame Size 3<br />

(L and C Rating Class)<br />

Max.<br />

Amp.<br />

Rating<br />

Current-Limiting<br />

3-Phase, 600V AC or<br />

120/280V AC, 277/480V AC<br />

Breaker Type Ampere Rating<br />

CFD6 70–250A<br />

CJD6 200–400A<br />

CLD6 450–600A<br />

CMD6 600–800A<br />

CND6 900–1200A<br />

CPD6 1200–1600A<br />

Interrupting current frame Ics (kAIR RMS) 50/60 Hz<br />

240 Volt 480 Volt 600 Volt<br />

2000A 65k 85k 100k 65k 85k 100k 65k 65k 65k<br />

3000A 65k 100k 150k 65k 100k 150k 65k 85k 100k<br />

5000A — 100k 150k — 100k 150k — 85k 100k<br />

In-Line Disconnect Cubicle, Approximate Dimensions<br />

Dimensions in Inches<br />

Description of Unit Type of Disconnect<br />

A B C<br />

Fusible Switch 800-1200A Vacu-Break 36 (914) 36 (914) 32 (813)<br />

Molded Case<br />

Circuit Breaker<br />

Digital Sentron<br />

Series MCCB's<br />

Power Circuit<br />

Breaker<br />

Bolted Pressure<br />

Switch<br />

JD6, LD6, MD6, ND6 36 (914) 28 (711) 28 (711)<br />

PD6, RD6 36 (914) 36 (914) 32 (813)<br />

SJD6, SLD6, SMD6, SND6 36 (914) 28 (711) 28 (711)<br />

SPD6, 1600A Frame 36 (914) 36 (914) 32 (813)<br />

WL Frame Size 1 48 (1219) 36 (914) 32 (813)<br />

WL Frame Size 2 48 (1219) 36 (914) 32 (813)<br />

WL Frame Size 3 48 (1219) 36 (914) 32 (813)<br />

800A 33 (838) 36 (914) 32 (813)<br />

1200-2500A 37 (940) 40 (1016) 32 (813)<br />

3000A 37 (940) 40 (1016) 48 (1219)<br />

4000A 41 (1041) 40 (1016) 48 (1219)<br />

15<br />

BUSWAY SYSTEMS<br />

Product Category: BUSW<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-33


Sentron Busway Systems<br />

Panelboards and Meter Center Modules<br />

Selection<br />

Meter center modules provide a quick and<br />

convenient method of connecting to metering<br />

devices for both commercial and industrial<br />

applications.<br />

Meter center modules connect at the side of a<br />

busway run to special joint stacks; these special<br />

joints can be added to existing busway to<br />

accommodate meter center module<br />

connections. When using multiple metering<br />

stacks, main disconnects are available if the<br />

system reaches the 6 circuit rule (see metering<br />

bulletin for further information).<br />

15<br />

BUSWAY SYSTEMS<br />

Dimensional Data Required<br />

Dimensions Inches (mm)<br />

“A” Distance between floor and bottom<br />

of meter center as required by the<br />

customer.<br />

“B” Dimension from bottom of meter<br />

center to centerline of meter center<br />

joint connection stack:<br />

100-125A Panel, B = 16.5 (419)<br />

200A Panel, B = 22.0 (559)<br />

“C” Equals “A” plus “B”, Minimum 16.0 (406)<br />

“D” Individual meter center height.<br />

Consult Modular Metering application<br />

information.<br />

15-34<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron Busway Systems<br />

Revised on 04/30/18<br />

Selection<br />

Meter Center Cubicles<br />

Meter center cubicles provide a quick and convenient method of connecting to metering devices for both commercial and<br />

industrial applications and have the main disconnect circuit breaker factory installed.<br />

Having the main disconnect built into the device reduces the required space on the right and left side of the busway. Meter<br />

center modules connect at the side of the cubicle frame box using an QC4 stack. Meter center cubicles are available for<br />

600 – 1200 Amp (L, M and N Frames). They are available with flexible meter center connections, left side, right side or both.<br />

(When ordering a meter center cubicle a QC4 stack must be ordered separately.)<br />

Molded Case Circuit Breaker Cubicles with Meter Tap Stack Provisions Dimensions, Inches (mm)<br />

Busway L Frame Breaker (250-600A) M Frame Breaker (250-800A) N Frame Breaker (800-1200A)<br />

Ampere Rating Width W A B C A B C A B C<br />

AL L-Rated<br />

225 — 3.9 (99) 32 (813) 24 (620) 16 (406) 37 (940) 26 (660) 16 (406) 37 (940) 26 (660) 16 (406)<br />

400 — 3.9 (99) 32 (813) 24 (620) 16 (406) 37 (940) 26 (660) 16 (406) 37 (940) 26 (660) 16 (406)<br />

600 — 3.9 (99) 32 (813) 24 (620) 16 (406) 37 (940) 26 (660) 16 (406) 37 (940) 26 (660) 16 (406)<br />

800 400 4.6 (117) 32 (813) 24 (610) 16 (406) 37 (940) 26 (660) 16 (406) 37 (940) 26 (660) 16 (406)<br />

1000 600 5.4 (137) 32 (813) 24 (610) 16 (406) 37 (940) 26 (660) 16 (406) 37 (940) 26 (660) 16 (406)<br />

1200 800 6.6 (168) 32 (813) 24 (610) 16 (406) 37 (940) 26 (660) 16 (406) 37 (940) 26 (660) 16 (406)<br />

1350 1000 7.6 (193) 32 (813) 24 (610) 16 (406) 37 (940) 26 (660) 16 (406) 37 (940) 26 (660) 16 (406)<br />

1600 1200 8.7 (221) 32 (813) 24 (610) 20 (490) 37 (940) 26 (660) 20 (490) 37 (940) 26 (660) 20 (490)<br />

2000 1350,1600 10.9 (277) 32 (813) 24 (610) 20 (490) 37 (940) 26 (660) 20 (490) 37 (940) 26 (660) 20 (490)<br />

2500 2000 13.7 (348) 32 (813) 24 (610) 23.5 (597) 37 (940) 26 (660) 23.5 (597) 37 (940) 26 (660) 23.5 (597)<br />

3000 2500 15.8 (401) 32 (813) 24 (610) 23.5 (597) 37 (940) 26 (660) 23.5 (597) 37 (940) 26 (660) 23.5 (597)<br />

3200 2000 17.3 (439) 32 (813) 24 (610) 23.5 (597) 37 (940) 26 (660) 28 (711) 37 (940) 26 (660) 28 (711)<br />

4000 3000,3200 20.3 (516) 32 (813) 24 (610) 28 (711) 37 (940) 26 (660) 28 (711) 37 (940) 26 (660) 28 (711)<br />

4000 3000,3200 20.3 (516) 32 (813) 24 (610) 28 (711) 37 (940) 26 (660) 28 (711) 37 (940) 26 (660) 28 (711)<br />

CU M-Rated<br />

225 — 3.9 (99) 32 (813) 24 (620) 16 (406) 37 (940) 26 (660) 16 (406) 37 (940) 26 (660) 16 (406)<br />

400 — 3.9 (99) 32 (813) 24 (620) 16 (406) 37 (940) 26 (660) 16 (406) 37 (940) 26 (660) 16 (406)<br />

600 — 3.9 (99) 32 (813) 24 (620) 16 (406) 37 (940) 26 (660) 16 (406) 37 (940) 26 (660) 16 (406)<br />

800 400 3.9 (99) 32 (813) 24 (620) 16 (406) 37 (940) 26 (660) 16 (406) 37 (940) 26 (660) 16 (406)<br />

1000 — 4.4 (112) 32 (813) 24 (610) 16 (406) 37 (940) 26 (660) 16 (406) 37 (940) 26 (660) 16 (406)<br />

1200 600 5.1 (130) 32 (813) 24 (610) 16 (406) 37 (940) 26 (660) 16 (406) 37 (940) 26 (660) 16 (406)<br />

1350 800 5.7 (145) 32 (813) 24 (610) 16 (406) 37 (940) 26 (660) 16 (406) 37 (940) 26 (660) 16 (406)<br />

1600 1000 6.7 (170) 32 (813) 24 (610) 16 (406) 37 (940) 26 (660) 16 (406) 37 (940) 26 (660) 16 (406)<br />

2000 1200,1350 8.2 (208) 32 (813) 24 (610) 20 (490) 37 (940) 26 (660) 20 (490) 37 (940) 26 (660) 20 (490)<br />

— 1600 8.7 (221) 32 (813) 24 (610) 20 (490) 37 (940) 26 (660) 20 (490) 37 (940) 26 (660) 20 (490)<br />

2500 2000 10.7 (272) 32 (813) 24 (610) 20 (490) 37 (940) 26 (660) 20 (490) 37 (940) 26 (660) 20 (490)<br />

3000 — 11.8 (300) 32 (813) 24 (610) 20 (490) 37 (940) 26 (660) 20 (490) 37 (940) 26 (660) 20 (490)<br />

3200 — 13.3 (335) 32 (813) 24 (610) 20 (490) 37 (940) 26 (660) 23.5 (597) 37 (940) 26 (660) 23.5 (597)<br />

4000 2500,3000,3200 15.3 (389) 32 (813) 24 (610) 23.5 (597) 37 (940) 26 (660) 23.5 (597) 37 (940) 26 (660) 23.5 (597)<br />

5000 4000 19.3 (491) 32 (813) 24 (610) 28 (711) 37 (940) 26 (660) 28 (711) 37 (940) 26 (660) 28 (711)<br />

15<br />

BUSWAY SYSTEMS<br />

Meter Center Module<br />

Main Disconnect Meter Module<br />

Meter Center Cubicle<br />

Side Mount<br />

Panelboard<br />

For this panelboard configuration,<br />

please contact Spartanburg<br />

plant for mounting information.<br />

Configuration only available<br />

for P2 and P3 panels in 240V or<br />

below applications.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-35


Sentron Busway Systems<br />

Installation and Application Information<br />

Revised on 06/30/18<br />

Selection<br />

15<br />

BUSWAY SYSTEMS<br />

Installation<br />

In preparation for installation of your<br />

busway systems, it is important to<br />

familiarize yourself with the following<br />

installation publications:<br />

b General Instructions For Handling,<br />

Installation, Operation and<br />

Maintenance of Busway Rated<br />

600 Volts or Less (NEMA Standards<br />

Publication BU1.1)<br />

b Storage, Installation and<br />

Maintainance Instructions for<br />

Sentron Busway<br />

These publications should be read<br />

through thoroughly and used as<br />

reference during installation to<br />

ensure proper installation procedures.<br />

All equipment should be inspected<br />

upon delivery. If the busway is not<br />

installed immediately, it should be<br />

stored in a clean, dry location. Factory<br />

supplied record drawings as well as<br />

installation tools should be accessible<br />

in preparation for installation.<br />

Video content illustrating bus plug<br />

installation, joint assembly, and support<br />

installation is also available and meant<br />

to compliment the two aforementioned<br />

documents.<br />

UL 1479 Fire Rated Installations<br />

Sentron Busway has been tested in<br />

accordance with UL 1479 and offers<br />

a certified two hour fire rating for<br />

gypsum wallboard construction and<br />

a three hour fire rating for concrete<br />

slab or block penetrations. These<br />

ratings were achieved using standard<br />

busway installed with SpecSeal sealant<br />

from Specified Technologies Inc. The<br />

SpecSeal fire stop system provides<br />

superior performance at the industry’s<br />

lowest installed cost.<br />

SIEMENS<br />

Order information:<br />

Sentron Busway Clean Order Form<br />

Sales Engineer:<br />

Order Status: Released Hold for Release<br />

Run Designation:<br />

Busway Catalog #:<br />

Plating Type: Tin or Silver<br />

Special Paint, provide paint chip<br />

Busway mounting position in reference to the floor<br />

Busway Check List:<br />

1) Field sketches or factory approval drawings attached?<br />

2) Dimensions from walls, column lines, etc.<br />

3) Wall, floor and roof thickness and pitch<br />

4) Floor Elevations<br />

a) Floor to floor<br />

b) Floor to ceiling<br />

5) Wall location Dimensions (indicate on drawing)<br />

6) Equipment pads / curbs Height<br />

7) Existing Busway to be extended cat #<br />

a) Phasing<br />

b) Nameplate Information<br />

c) Match to competitor, Contact the plant<br />

8) Special SWBD connection, provide details<br />

9) Phase Transpositions: (indicate phasing on drawing)<br />

Special Comments<br />

Example page of busway clean order<br />

form. Please contact your local Siemens<br />

sales representative.<br />

Measuring<br />

Critical to the success of any busway<br />

installation is the layout and the<br />

accurate measuring of the busway. First<br />

and foremost:<br />

Select a route for your busway that will<br />

require the fewest fittings and the<br />

maxumum number of 10' (3.05m)<br />

sections. It is important that the busway<br />

system be designed to meet the<br />

requirements of the National Electric<br />

Code for Busway. There are a number of<br />

techniques that may be used to ensure an<br />

accurate measurement before purchasing<br />

and installing the busway. The following<br />

tools will be required during layout and<br />

measuring:<br />

b Laser measurement device<br />

b Measuring stick<br />

b Chalkline<br />

b Plumb bob<br />

b Marker<br />

Watch<br />

Busway joint<br />

assembly<br />

video<br />

Watch SLVB<br />

Bus Plug<br />

installation<br />

video<br />

Watch<br />

Busway<br />

support<br />

video<br />

Support and installation videos.<br />

Minimal Clearances<br />

Minimum clearances for installing feeder<br />

busway are shown. Additional clearance<br />

may be required for plug-in devices<br />

larger than 100A fusible and 250A circuit<br />

breaker.<br />

15-36<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron Busway Systems<br />

General Information<br />

Revised on 04/30/18<br />

Selection<br />

Recommended Measurement Steps<br />

1. Using systems requirements for<br />

amperage, voltage, and conductors,<br />

determine the physical size of the<br />

busway. This is important when<br />

setting minimum clearances from<br />

walls, columns, ceilings and other<br />

obstructions. See page 30 for<br />

minimal clearances.<br />

2. Prior to any layout, review the<br />

complete area to determine the best<br />

location for the run. Special attention<br />

needs to be given to existing<br />

equipment such as plumbing, HVAC,<br />

steel columns, beams and permanent<br />

structures.<br />

3. Measure all dimensions from fixed<br />

points such as columns, walls, floors<br />

and ceilings.<br />

4. Make a preliminary sketch showing<br />

proposed busway routing, elevations<br />

and obstructions. Be sure to show<br />

all floor and wall locations including<br />

thickness.<br />

5. Where plug-in devices are<br />

being used, be sure to allow for<br />

proper operation clearances. See<br />

dimensional requirements shown<br />

in the bus plug section of this<br />

publication.<br />

Reference the following documents<br />

online at www.usa.siemens.com/<br />

busway.<br />

• Sentron Quick Reference<br />

• Busway Order Entry Checklist<br />

• Sentron Busway Installation and<br />

Instruction Guide<br />

Maintenance<br />

In order to maintain system<br />

performance, it is necessary to perform<br />

regular maintenance on your busway<br />

system. Siemens Storage, Installation<br />

and Maintenance Instructions, and<br />

NEMA Publication BU1.1 should be<br />

used as a guide to proper maintenance<br />

procedures. Routine maintenance of<br />

your busway system will increase its<br />

life and performance.<br />

Custom Product<br />

With a 60 year history in designing<br />

and manufacturing Busway Systems,<br />

Siemens can develop custom solutions<br />

to meet specific job requirements.<br />

Siemens specializes in custom<br />

engineered busway sections,<br />

connections, and bus plugs. Consult<br />

your local Siemens sales office for<br />

details on custom pricing and ordering<br />

Connecting to Existing Equipment<br />

Do you have existing power distribution<br />

equipment (non-Sentron) that you<br />

would like to run Sentron Busway to<br />

or from? Siemens can engineer special<br />

connection pieces that allow you to<br />

connect Sentron Busway quickly and<br />

efficiently.<br />

Transformer Connections<br />

Siemens can connect Sentron Busway<br />

to almost any transformer. All you need<br />

to do is provide complete drawings of<br />

transformer secondary connections with<br />

detailed drilling pattern and phasing<br />

information to your local Siemens sales<br />

engineer and they can order you a<br />

custom designed connection piece.<br />

Paint<br />

Sentron Busway products have a<br />

protective finish of ANSI 61 gray<br />

(standard) polyester urethane powder<br />

paint. The paint is electrostatically<br />

applied to all housing surfaces. Colors<br />

other than ANSI 61 gray may be special<br />

ordered.<br />

Low Current Density Busway Sentron<br />

Busway may be ordered as 1000 A/in 2<br />

Copper or 750 A/in 2 Aluminum.<br />

Conversion is as follows:<br />

Required M or L Rating<br />

AL<br />

L-Rated<br />

225 —<br />

400 —<br />

600 —<br />

800 400<br />

1000 600<br />

1200 800<br />

1350 1000<br />

1600 1200<br />

2000 1350,1600<br />

2500 2000<br />

3000 2500<br />

3200 2000<br />

4000 3000,3200<br />

Required M or L Rating<br />

AL<br />

L-Rated<br />

225 —<br />

400 —<br />

600 —<br />

800 400<br />

1000 —<br />

1200 600<br />

1350 800<br />

1600 1000<br />

2000 1200, 1350<br />

— 1600<br />

2500 2000<br />

3000 —<br />

3200 —<br />

4000 2500, 3000<br />

5000 4000<br />

“L” Rating = 750 A/in 2 Aluminum<br />

“M” Rating = 1000 A/in 2 Copper<br />

1600 “M” rated is dedicated offering.<br />

15<br />

BUSWAY SYSTEMS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-37


Sentron Busway Systems<br />

General Information<br />

Revised on 04/30/18<br />

Selection<br />

15<br />

BUSWAY SYSTEMS<br />

Applications – 200% Neutral Option<br />

Power system harmonics are created<br />

by numerous types of non-linear loads<br />

which are often very high in harmonic<br />

content. The harmonics generated create<br />

problems in electrical systems and<br />

equipment. The presence of nonlinear<br />

loads can result in overheated neutrals<br />

and lead to deterioration of equipment<br />

performance and a reduced equipment<br />

life cycle. In order to prevent such problems<br />

from occurring, the Computer and<br />

Business Equipment Manufacturers<br />

Association (CBEMA) recommends<br />

that the neutral be oversized to at<br />

least 173% of the ampacity of the<br />

phase conductors to prevent problems.<br />

Sentron Busway offers two fully rated<br />

bus bars, therefore providing twice the<br />

current carrying surface as the phase<br />

bars. Each neutral bar is plated with the<br />

same tin plating and insulated with the<br />

same electrostatically applied epoxy<br />

insulation as the phase bars. This 200%<br />

neutral capacity helps prevent overheating<br />

caused by non-linear loads.<br />

Isolated Ground<br />

Sentron Busway is available with an<br />

optional isolated ground. This isolated<br />

ground provides a clean ground path for<br />

high frequency signals coming through<br />

the ground. This option is very useful in<br />

applications where there are computers<br />

or diagnostic equipment. The isolated<br />

ground option is often used in hospitals<br />

and higher technology industry applications.<br />

Services – Power II Fit Final<br />

Connection Program<br />

A “Final Connection” section is a length<br />

of busway inserted into a run of busway<br />

after the major portion of the busway<br />

run has been installed. This allows the<br />

release of the majority of the busway<br />

run long before the final dimensions are<br />

known.<br />

Final Connection pieces must be<br />

identified at the time of the original<br />

order release with approximate date<br />

of Final Connection order. The Final<br />

Connection order form should be<br />

emailed to Busway Customer Service.<br />

For program details visit our website:<br />

www.usa.siemens.com/busway or<br />

contact your local Siemens sales office.<br />

Measuring and Layout<br />

For large jobs, Siemens Busway<br />

Systems offer assistance with measuring<br />

and layout of the busway. This service<br />

is negotiated on a job by job basis.<br />

Emergency Service<br />

Siemens provides a 24-hour emergency<br />

service call center where you can call<br />

at any time for emergency service.<br />

1.800.241.4453 will put you in touch<br />

with a trained professional who will<br />

help assess the situation and put you in<br />

touch with a product expert.<br />

15-38<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron Busway Systems<br />

Siemens Sentron Busway Quick Reference<br />

Revised on 06/30/18<br />

General<br />

Siemens Sentron Busway Quick Reference<br />

Critical Dimensions:<br />

Busway that passes through a wall, ceiling or floor:<br />

b Centerline of a joint to the wall, ceiling or floor = 7 in. min.<br />

b Centerline of a joint (above a floor support) to a floor = 16 in. min.<br />

b Joints cannot be positioned inside a wall, ceiling or floor<br />

(joints must be accessible for maintenance).<br />

Feeder Busway clearances:<br />

b From the top of the busway to a ceiling/floor/wall or other busway = 6 in. min.<br />

b From the side of the busway to a ceiling/floor/wall or other busway = 4 in. min.<br />

Plug-in Busway clearances:<br />

b Plug-In busway clearances depend on the configuration of bus plugs<br />

(see bus pug clearance charts in the Sentron Selection and Application Guide)<br />

Feeder Busway minimal clearances<br />

b Otherwise, clearances for feeder busway apply.<br />

b Note orientation of the operating handle and provide clearance for access & operation.<br />

Feeder Busway length:<br />

b Minimum length = 14.38 in.<br />

b Maximum length = 10 ft.<br />

Plug-In & Riser length:<br />

b Available only in 4, 6, 8 and 10 ft. lengths<br />

Flat Elbow section:<br />

b Maximum leg length = 4 ft.<br />

b Minimum leg length: Varies according to amperage and bus bar material<br />

Edge Elbow section:<br />

b Maximum length = 4 ft.<br />

b Minimum leg length = 10 in.<br />

Combination and Offset Elbows:<br />

b Maximum leg lengths = 4 ft.<br />

b Minimum leg lengths: varies according to amperage and bus bar material<br />

Elbow - Stub Combinations:<br />

b Maximum leg length = 4 ft.<br />

b Minimum leg length = 2.50 in. + (case size x .5)<br />

Critical Details:<br />

b Busway DRAWINGs must include all relevant dimensions.<br />

b CENTERLINE dimensions are expected (please note any dimensions that are not center line dimensions).<br />

b WALLs and FLOORs must be located (wall & floor thickness must be included).<br />

b Locate the FRONT of all switchboards and provide the phasing of any existing boards (advise if any PADs are located<br />

under boards and height of pads).<br />

b When using One-SIDED plug-in busway please note the desired direction of the load side of bus plugs (G,A,B,C,N from<br />

left to right will position the load side to the bottom and “UP is On” handle operation)<br />

b TRANSFORMER THROAT connections require complete details.<br />

b Horizontal plug-in busway must be oriented with the A phase on top (bolt head on top).<br />

b In-Line Disconnect CUBICLEs are engineered to order. The FRONT of the cubicle and Breaker information must<br />

be specified.<br />

b Panels - panel type and size / if a certain panel or breaker height is required (those dimensions)<br />

b Curb height<br />

Intermediate Hangers<br />

b Add qty (1) Intermediate Hanger for floor to ceiling height greater than 16ft. Consult factory if greater than 32 ft.<br />

Expansion Sections:<br />

b Qty (1) Expansion Section should be used for every 200 ft of continuous Busway run length, length, at every transition<br />

to a vertical run over 40' in continuous length, and at each building expansion joint.<br />

Outdoor Busway:<br />

b Route busway to minimize outdoor busway run length.<br />

b Call factory before quoting outdoor busway runs over 50 ft.<br />

b Avoid installing busway near exhaust pipes that may generate steam or caustic vapors.<br />

15<br />

BUSWAY SYSTEMS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-39


Sentron Busway Systems<br />

Programs and Services<br />

Revised on 06/30/18<br />

Selection<br />

15<br />

BUSWAY SYSTEMS<br />

What is the Power II Fit Program?<br />

Siemens PIIF Program compensates for dimensional<br />

deviations that may result in busway layouts. With the PIIF<br />

Program, specific dimensions on straight sections and/or<br />

elbows may be left out of factory released drawings. After<br />

the busway run has been installed (minus PIIF pieces),<br />

final measurements are taken and sent to your Siemens<br />

representative.<br />

Why use the Power II Fit Program?<br />

The P II F Program can save you both time and money by<br />

eliminating uncertainty in busway measurements. When you<br />

take advantage of the P II F Program, your busway runs fit<br />

exactly the first time, eliminating incorrect pieces and costly<br />

reordering time.<br />

When should the Power II Fit Program be used?<br />

The PIIF Program will benefit you when you are uncertain<br />

of exact dimensions on long busway runs and when difficult<br />

contour situations require special attention. Common<br />

applications of the PIIF Program include tie bus or other<br />

configurations in which the busway origin and termination are<br />

rigidly defined.<br />

Ordering Details<br />

• Identify Siemens Busway PIIF Pieces at time of original<br />

order. Busway Customer Service approves PIIF Pieces.<br />

• Send PIIF Order Form to Busway Customer Service<br />

when exact measurements are known.<br />

• Busway Customer Service acknowledges PIIF Order and<br />

PIIF pieces ship within lead time per table.<br />

Field Dimension Measurement Guide<br />

Program Details<br />

• Product Line: SENTRON.<br />

• Pricing: Included with original order entry.<br />

Table below only applies to Sentron Busway.<br />

Consult factory for Legacy Products.<br />

Piece Type 1-3 Pieces a Pieces a<br />

1-5 Total<br />

Straight<br />

Sections<br />

5 days c 5-10<br />

Working<br />

Days<br />

Standard 90<br />

Elbows b N/A 5-15<br />

Working<br />

Days<br />

Non Standard N/A Consult<br />

Fittings b lead times<br />

Elbows / Other<br />

factory for<br />

6-10 Total<br />

Pieces a<br />

10-15<br />

Working<br />

Days<br />

10-20<br />

Working<br />

Days<br />

Consult<br />

factory for<br />

lead times<br />

11 or more<br />

Total Pieces a<br />

Consult<br />

factory for<br />

lead times<br />

Consult<br />

factory for<br />

lead times<br />

Consult<br />

factory for<br />

lead times<br />

a Lead times are in business days from receipt of complete PIIF Order Form. The number<br />

of pieces is calculated based of how many pieces are released in a given week on<br />

any project. All orders ship via standard carrier originating from Spartanburg, SC. Ex:<br />

4 straight sections and 2 elbows would be considered 6 total pieces and they would<br />

be ready to ship in 10-20 days. All field fit pieces must be shown on layout drawings<br />

issued by factory. If pieces are not shown on factory layout drawings as field fits they<br />

are not eligible for the field fit program.<br />

b Standard 90 elbows are defined in the selection and application guide as 90 degree<br />

elbows. Offsets & Combinations will be considered Non Standard Elbows or Other<br />

Fittings.<br />

c Pending material availability. All sections must be shorter than 5ft from center line to<br />

center line if air freight is required. Lengths of pieces should be determined during the<br />

approval drawing stage.<br />

90 Degree Elbow Sections:<br />

Measure the distance "X" and "Y" between the housings of<br />

the connecting sections. Forward this to the factory via the<br />

Power II Fit Order Form and we will calculate the lengths of<br />

elbow required.<br />

X<br />

Y<br />

X<br />

Y<br />

End of<br />

side<br />

Channel<br />

Straight Sections<br />

Measure the distance "A" between the housings of the<br />

connecting sections. Forward this to the factory via the<br />

Power II Fit Order Form and we will calculate the length<br />

of busway required.<br />

(Shown with Joint Covers Removed)<br />

Elbow Stacks:<br />

Measure the distance "A" between the housings of the<br />

connecting sections. Forward this to the factory via the<br />

Power II Fit Order Form and we will calculate the lengths of<br />

elbow required.<br />

A<br />

(Shown with Joint Covers Removed)<br />

End of<br />

channel<br />

A<br />

A<br />

End of<br />

side<br />

Channel<br />

15-40<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron Busway Systems<br />

Programs and Services<br />

What is the Power II Measure service?<br />

Siemens Power II Measure (P II M) service provides<br />

professional busway routing and measurement by a factory<br />

representative. The Siemens representative will meet with<br />

the designated site contact to review project details and<br />

discuss routing options. Using a laser measuring device,<br />

all pertinent site measurements will be recorded and then<br />

transferred to a CAD approval drawing(s). The P II M service<br />

guarantees correct alignment and routing of the busway. If<br />

there are any errors in the busway routing that resulted from<br />

Siemens, replacement busway items will be provided at no<br />

charge.<br />

Why use the Power II Measure service?<br />

The P II M service can save you both time and money by:<br />

• Ensuring the most cost effective busway routing<br />

• Ensuring accurate measurements<br />

• Reducing order engineering lead-time<br />

Revised on 04/30/18<br />

Selection<br />

Program details<br />

• Product Line: Sentron, XJL, XLU, BD<br />

• Pricing: Fixed daily rate includes travel expenses,<br />

site review, measurement service and approval drawings<br />

• Deliverable: An electronic CAD approval package will be submitted<br />

within 3 weeks of the site visit. The drawing package<br />

will include isometric busway routing with gear orientation,<br />

and any special application notes/details.<br />

Ordering details<br />

• The P II M service should be ordered at the same time as<br />

the busway<br />

• The P II M service may be ordered for project cost estimation<br />

• Allow 2 weeks notice to schedule the P II M service<br />

When should the Power II Measure service be used?<br />

The P II M service can be beneficial for all projects (new<br />

or existing, large or small). The P II M service is especially<br />

beneficial for large and/or complex projects.<br />

15<br />

BUSWAY SYSTEMS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-41


Sentron Bus Plugs<br />

Revised on 06/30/18<br />

Table of Contents<br />

15<br />

BUSWAY SYSTEMS<br />

Non-Metered Sentron 3/6 Bus Plug<br />

Sentron SLVB Bus Plug<br />

Sentron Busway Systems<br />

Sentron Bus Plug Overview 15-43<br />

Bus Plug Catalog Numbering System 15-44<br />

Circuit Breaker Bus Plugs Dimensions and Weights 15-45<br />

Bus Plugs with Standard Circuit Breakers 15-46<br />

Bus Plugs with Current Limiting Circuit Breakers 15-47<br />

Circuit Breaker Bus Plugs Dimensions and Weights 15-48<br />

Wall Clearance and Circuit Breaker Bus Plug Dimensions 15-49<br />

Fusible Bus Plugs Catalog Numbering System 15-50<br />

Fusible Bus Plugs Ratings 15-51<br />

Fusible Plugs Selection and Ordering 15-52<br />

Fusible Bus Plugs Dimensions and Weights 15-53 – 15-54<br />

Wall Clearance and Fusible Bus Plug Dimensions 15-55<br />

SPD Bus Plugs 15-56<br />

SPD Bus Plugs Catalog Numbering System 15-57<br />

SPD Bus Plugs Dimensions and Weights 15-58<br />

3/6 Bus Plugs 15-59<br />

3/6 Bus Plugs Catalog Numbering System 15-60<br />

3/6 Bus Plugs Product Configuration 15-61<br />

3/6 Bus Plugs Dimensions and Weights 15-62 – 15-63<br />

15-42<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron Bus Plugs<br />

Sentron Bus Plug Overview<br />

Revised on 04/30/18<br />

Overview<br />

SENTRON Bus Plugs are engineered<br />

with the installer and end user in mind.<br />

The installer will benefit from the<br />

numerous features, such as factory<br />

installed circuit breakers, compact<br />

footprint, generous wirebend space,<br />

and dual interlocks. The end user will<br />

appreciate the visible position indicator,<br />

as well as the spring loaded pad<br />

lockable latch which prevents access to<br />

unauthorized personnel.<br />

SENTRON Bus Plugs are designed<br />

with an interlock device to prevent<br />

the door from being opened when the<br />

disconnect is on. This also prevents the<br />

disconnect from being turned on while<br />

the door is open. The interlock ensures<br />

that the protective device is “OFF”<br />

prior to installation or removal of the<br />

bus plug. Once the bus plug is properly<br />

installed, a spring - loaded, padlock<br />

latch provides additional security by<br />

preventing unauthorized access to the<br />

unit.<br />

PLUG-IN OUTLET<br />

COVER<br />

Alignment and interlock stabs are<br />

features of the Sentron Bus Plugs<br />

engineered to prevent improper<br />

installation of the unit. Guide stabs<br />

prevent installing the bus plug 180<br />

degrees out of rotation. In addition,<br />

the stabs provide vertical support for<br />

vertical applications. The bus plug<br />

ground stabs are designed to ensure<br />

positive contact with both the integral<br />

and optional internal busway grounds<br />

before the bus plug fingers contact the<br />

phase and neutral bars. Sentron Bus<br />

Plugs also feature bolt-on mounting<br />

to the busway housing for secure<br />

attachment.<br />

Sentron Bus Plugs can be configured<br />

for horizontal or vertical applications.<br />

The following Bus Plugs can be<br />

mounted (side by side) five (5) per<br />

busway side channel (Total 10 per 10’<br />

Section).<br />

n 30-600 SLVBH Fusible (Horizontal) a<br />

n 30-200 SLVBR Fusible (Riser) a<br />

n 30-400 Circuit Breaker a<br />

n 10-100A 3/6 Bus Plug (Horizontal) b<br />

TWIN ALIGNMENT<br />

SLOTS<br />

BUSWAY INTERLOCK<br />

LEVER<br />

Sentron SLVB Fusible Bus Plugs<br />

feature a direct drive mechanism. The<br />

operating handle mounts directly to the<br />

switch mechanism for fewer moving<br />

parts.<br />

Enclosure Ratings:<br />

n IP40<br />

n IP55<br />

Conductors:<br />

n 3-phase, 3-wire<br />

n 3-phase, 4-wire<br />

n 3-phase, 4-wire 200% neutral (400A<br />

and below)<br />

Grounding:<br />

n Integral (Housing)<br />

n Internal<br />

n Isolated<br />

BUS PLUG<br />

MOUNTING SCREWS<br />

15<br />

BUSWAY SYSTEMS<br />

COVER INTERLOCK<br />

SCREW<br />

COVER INTERLOCK<br />

SCREW<br />

TWIN<br />

ALIGNMENT / INTERLOCK<br />

TABS<br />

STOP FEATURE<br />

SUPPORT RAIL<br />

BUS PLUG<br />

HANDLE<br />

STOP<br />

FEATURE<br />

SUPPORT RAIL<br />

VERIFICATION<br />

WINDOW<br />

Note: SLVBH Horizontal Application Shown.<br />

a Contact Siemens for 200% Neutral Applications.<br />

b IP55 enclosure not available.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-43


Sentron Circuit Breaker Bus Plugs<br />

Catalog Numbering System<br />

Revised on 04/30/18<br />

Selection / Application<br />

Sentron Bus Plugs—Circuit Breaker (Installed)<br />

S L E C S a 3 2 0 1 5 0 G E D 2<br />

15<br />

BUSWAY SYSTEMS<br />

Plug Type<br />

SL = Sentron II<br />

Circuit Breaker Frame<br />

E = 15–125A<br />

F = 70–250A<br />

J = 200–400A<br />

L = 250–600A<br />

M = 500–800A<br />

Enclosure Type<br />

C = Circuit Breaker Enclosure<br />

L = Current Limiting Enclosure<br />

Cradle Designation<br />

S = 3Ø3W and 3Ø4W > 400A<br />

3Ø5W (200%N) > 200A<br />

Configuration<br />

3 = 3Ø, 3W<br />

4 = 3Ø, 4W<br />

5 = 3Ø, 4W 200% neutral cd<br />

Breaker Voltage<br />

2 = 240V e<br />

4 = 480V f<br />

6 = 600V<br />

Ampere Trip Rating<br />

IP Rating<br />

0 = IP40<br />

4 = IP55<br />

Ground Designation<br />

G = Internal Ground<br />

IG = Isolated Ground<br />

Circuit Breaker Frame Identification<br />

a The S digit is only used on 3- and 4-wire (100%N) plugs that are greater<br />

than 400A and 200%N plugs greater than 200A. Lower amperage plugs<br />

do not require this digit. (Ex. SLEC32060ED2)<br />

b The G and IG digits are used to specify internal and isolated ground<br />

respectively. Integral (housing) ground plugs do not require this digit.<br />

(Ex. SLEC360150ED6)<br />

c Available through 250A only.<br />

d Available with E and F Frame breakers only.<br />

e Available with ED2 breakers only.<br />

f Available with ED4 and HHED6 breakers only.<br />

15-44<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron Bus Plugs<br />

Circuit Breaker Bus Plugs Dimensions and Weights<br />

Revised on 06/30/18<br />

Overview<br />

Standard Circuit Breakers, Bus Plug Ratings a<br />

Plug-In<br />

Units<br />

Series<br />

Circuit<br />

Breaker<br />

Max. Rating<br />

Frame<br />

Size<br />

Max. Short<br />

Circuit<br />

Current Rating<br />

SLEC 125A, 600V E Frame 100kA, 240V, 3 ph<br />

65kA, 480V, 3 ph a<br />

25kA, 600V, 3 ph<br />

SLFC 250A, 600V F Frame 200kA, 240V, 3 ph<br />

100kA, 480V, 3 ph<br />

25kA, 600V, 3 ph<br />

SLJC 400A, 600V J Frame 200kA, 240V, 3 ph<br />

100kA, 480V, 3 ph<br />

50kA, 600V, 3 ph<br />

SLLCS 600A, 600V L Frame 200kA, 240V, 3 ph<br />

100kA, 480V, 3 ph<br />

50kA, 600V, 3 ph<br />

SLMCS 800A, 600V M Frame 200kA, 240V, 3 ph<br />

100kA, 480V, 3 ph<br />

65kA, 600V, 3 ph<br />

Current Limiting Circuit Breakers, Bus Plug Ratings a<br />

Plug-In<br />

Units<br />

Series<br />

Circuit<br />

Breaker<br />

Max. Rating<br />

Frame<br />

Size<br />

Max. Short<br />

Circuit<br />

Current Rating<br />

SLEL 125A, 600V CED Frame 200KA, 240V, 3 ph<br />

200KA, 480V, 3 ph<br />

100KA, 600V, 3 ph<br />

SLFL 250A, 600V CFD Frame 200KA, 240V, 3 ph<br />

200KA, 480V, 3 ph<br />

100KA, 600V, 3 ph<br />

SLJL 400A, 600V CJD Frame 200KA, 240V, 3 ph<br />

150KA, 480V, 3 ph<br />

100KA, 600V, 3 ph<br />

SLLLS 600A, 600V CLD Frame 200KA, 240V, 3 ph<br />

150KA, 480V, 3 ph<br />

100KA, 600V, 3 ph<br />

SLMLS 800A, 600V CMD Frame 200KA, 240V, 3 ph<br />

100KA, 480V, 3 ph<br />

65KA, 600V, 3 ph<br />

Sentron Circuit Breaker Bus Plugs feature an easy to read<br />

“position indicator” label, designed to be visible from the<br />

floor, that clearly marks whether the bus plug is in the<br />

“Off,” “On,” or “Tripped” position. Circuit breaker bus plugs<br />

are available in frame sizes from 125 amps to 800 amps with<br />

interrupting ratings of standard, high or current limiting.<br />

Circuit breaker bus plugs will be shipped complete with<br />

factory installed circuit breakers. The following Siemens<br />

molded case circuit breaker frames may be ordered with<br />

Sentron Circuit Breaker Bus Plugs: ED2, ED4, ED6, HED4,<br />

HHED6, CED6, FXD6, FD6, HFD6, CFD6 JXD6, JD6, HJD6,<br />

CJD6, LXD6, HLD6, CLD6, MXD6, HMD6, CMD6.<br />

Refer to the diagram on page 15-44 for easy ordering<br />

instructions.<br />

Sentron circuit breaker bus plugs can be custom configured to<br />

meet application specific requirements.<br />

Consult your local Siemens sales office for details on custom<br />

pricing and ordering.<br />

15<br />

BUSWAY SYSTEMS<br />

a Available in IP40 or IP55 variant.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-45


Sentron Circuit Breaker Bus Plugs<br />

Bus Plugs with Standard Circuit Breakers abcd<br />

Revised on 04/30/18<br />

Selection<br />

15<br />

BUSWAY SYSTEMS<br />

Ampere<br />

Rating<br />

Catalog<br />

Number<br />

E Frame 3-Pole, 240 Volt, ED2 Breaker<br />

SLEC32***0ED2<br />

15-60A SLEC32***0GED2<br />

SLEC32***0IGED2<br />

SLEC32***0ED2<br />

70-100A SLEC32***0GED2<br />

SLEC32***0IGED2<br />

E Frame 3-Pole, 480 Volt, ED4 Breaker<br />

SLEC34***0ED4<br />

15-60A SLEC34***0GED4<br />

SLEC34***0IGED4<br />

SLEC34***0ED4<br />

70-100A SLEC34***0GED4<br />

SLEC34***0IGED4<br />

SLEC34***0ED4<br />

110-125A SLEC34***0GED4<br />

SLEC34***0IGED4<br />

E Frame 3-Pole, 600 Volt, ED6 Breaker<br />

SLEC36***0ED6<br />

15-60A SLEC36***0GED6<br />

SLEC36***0IGED6<br />

SLEC36***0ED6<br />

70-100A SLEC36***0GED6<br />

SLEC36***0IGED6<br />

SLEC36***0ED6<br />

110-125A SLEC36***0GED6<br />

SLEC36***0IGED6<br />

F Frame 3-Pole, 600 Volt, FXD6 Breaker<br />

SLFC36***0FXD6<br />

70-225A SLFC36***0GFXD6<br />

SLFC36***0IGFXD6<br />

SLFC362500FXD6<br />

250A<br />

SLFC362500GFXD6<br />

SLFC362500IGFXD6<br />

J Frame 3-Pole, 600 Volt, JXD6 Breaker<br />

SLJC36***0JXD6<br />

200-400A d SLJC36***0GJXD6<br />

SLJC36***0IGJXD6<br />

Ampere Catalog Ampere Catalog<br />

Rating Number Rating Number<br />

E Frame 4-Pole, 240 Volt, ED2 Breaker<br />

E Frame 4-Pole, 600 Volt, ED6 Breaker<br />

J Frame 4-Pole, 600 Volt, JXD6 Breaker<br />

SLJC46***0JXD6<br />

200-400A d SLJC46***0GJXD6<br />

SLJC46***0IGJXD6<br />

E Frame 200% Neutral<br />

SLEC42***0ED2<br />

SLEC52***0ED2<br />

15-60A SLEC42***0GED2 15-60A SLEC52***0GED2<br />

SLEC42***0IGED2<br />

SLEC52***0IGED2<br />

SLEC42***0ED2<br />

SLEC52***0ED2<br />

70-100A SLEC42***0GED2 70-100A SLEC52***0GED2<br />

SLEC42***0IGED2<br />

SLEC52***0IGED2<br />

E Frame 4-Pole, 480 Volt, ED4 Breaker<br />

E Frame 200% Neutral<br />

15-60A SLEC44***0ED4 SLEC54***0ED4<br />

SLEC44***0GED4 15-60A SLEC54***0GED4<br />

SLEC44***0IGED4<br />

SLEC54***0IGED4<br />

70-100A SLEC44***0ED4 SLEC54***0ED4<br />

SLEC44***0GED4 70-100A SLEC54***0GED4<br />

SLEC44***0IGED4<br />

SLEC54***0IGED4<br />

110-125A SLEC44***0ED4 SLEC54***0ED4<br />

SLEC44***0GED4 110-125A SLEC54***0GED4<br />

SLEC44***0IGED4<br />

SLEC54***0IGED4<br />

E Frame 200% Neutral<br />

SLEC46***0ED6<br />

SLEC56***0ED6<br />

15-60A SLEC46***0GED6 15-60A SLEC56***0GED6<br />

SLEC46***0IGED6<br />

SLEC56***0IGED6<br />

SLEC46***0ED6<br />

SLEC56***0ED6<br />

70-100A SLEC46***0GED6 70-100A SLEC56***0GED6<br />

SLEC46***0IGED6<br />

SLEC56***0IGED6<br />

SLEC46***0ED6<br />

SLEC56***0ED6<br />

110-125A SLEC46***0GED6 110-125A SLEC56***0GED6<br />

SLEC46***0IGED6<br />

SLEC56***0IGED6<br />

F Frame 4-Pole, 600 Volt, FXD6 Breaker F Frame 200% Neutral<br />

SLFC46***0FXD6<br />

SLFC56***0FXD6<br />

70-225A SLFC46***0GFXD6 70-200A SLFC56***0GFXD6<br />

SLFC46***0IGFXD6<br />

SLFC56***0IGFXD6<br />

SLFC462500FXD6<br />

SLFC56***0FXD6<br />

250A SLFC462500GFXD6 225-250A SLFC56***0GFXD6<br />

SLFC462500IGFXD6<br />

SLFC56***0IGFXD6<br />

L Frame 3-Pole, 600 Volt, LXD6 Breaker<br />

SLLCS36***0LXD6<br />

450-600A d SLLCS36***0GLXD6<br />

SLLCS36***0IGLXD6<br />

M Frame 3-Pole, 600 Volt, MXD6 Breaker<br />

SLMCS36***0MXD6<br />

500-800A d SLMCS36***0GMXD6<br />

SLMCS36***0IGMXD6<br />

L Frame 4-Pole, 600 Volt, LXD6 Breaker<br />

SLLCS46***0LXD6<br />

450-600A d SLLCS46***0GLXD6<br />

SLLCS46***0IGLXD6<br />

M Frame 4-Pole, 600 Volt, MXD6 Breaker<br />

SLMCS46***0MXD6<br />

500-800A d SLMCS46***0GMXD6<br />

SLMCS46***0IGMXD6<br />

Description<br />

Spring Kit<br />

Catalog<br />

Number<br />

SXSK<br />

NOTE: Used on 400A and larger bus plugs that require<br />

auxiliary support and that are mounted on vertical/<br />

riser busway. Kit contains two springs (part number<br />

32-9909-04). One kit required per bus plug. Spring kits are<br />

automatically included when 400A and larger bus plug<br />

is selected.<br />

a Replace “***” with breaker trip rating.<br />

Example: SLEC36060ED6, for 60A trip.<br />

b All plugs shown have an IP40 rating, if IP54/55 is desired<br />

substitute ”4” for ”0” in position 10 (or 11 for cradle<br />

plugs):<br />

E Frame: Ex. SLEC360604ED6<br />

F Frame: Ex. SLFC360704FXD6<br />

J Frame: Ex. SLJC361004JXD6<br />

L Frame: Ex. SLLCS365004LXD6<br />

M Frame: Ex. SLMCS368004MXD6<br />

c For the following breaker substitutions, change the<br />

catalog number suffix:<br />

15-60A: HHED6 Ex. SLEC36***0HHED6<br />

70-100A: HHED6 Ex. SLEC36***0HHED6<br />

110-125A: HHED6 Ex. SLEC36***0HHED6<br />

F Frame: FD6 Ex. SLFC36***0FD6<br />

F Frame: HFD6 Ex. SLFC36***0HFD6<br />

J Frame: JD6 Ex. SLJC36***0JD6<br />

J Frame: HJD6 Ex. SLJC36***0HJD6<br />

L Frame: LD6 Ex. SLLCS36***0LD6<br />

L Frame: HLD6 Ex. SLLCS36***0HLD6<br />

M Frame: MD6 Ex. SLMCS36***0MD6<br />

M Frame: HMD6 Ex. SLMCS36***0HMD6<br />

d 400A and larger bus plugs that require auxiliary support.<br />

See also SXSK Spring Kit.<br />

15-46<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: BPLU


Sentron Circuit Breaker Bus Plugs<br />

Bus Plugs with Current Limiting Circuit Breakers b<br />

Revised on 04/30/18<br />

Selection<br />

Ampere<br />

Rating<br />

Catalog<br />

Number<br />

E Frame 3-Pole, 600 Volt, CED6 Breaker<br />

SLEL36***0CED6<br />

15-60A SLEL36***0GCED6<br />

SLEL36***0IGCED6<br />

SLEL36***0CED6<br />

70-100A SLEL36***0GCED6<br />

SLEL36***0IGCED6<br />

SLEL36***0CED6<br />

110-125A SLEL36***0GCED6<br />

SLEL36***0IGCED6<br />

F Frame 3-Pole, 600 Volt, CFD6 Breaker<br />

SLFL36***0CFD6<br />

100-225A SLFL36***0GCFD6<br />

SLFL36***0IGCFD6<br />

SLFL362500CFD6<br />

250A<br />

SLFL362500CGFD6<br />

SLFL362500ICGFD6<br />

J Frame 3-Pole, 600 Volt, CJD6 Breaker<br />

SLJL36***0CJD6<br />

200-400A c SLJL36***0CGJD6<br />

SLJL36***0ICGJD6<br />

L Frame 3-Pole, 600 Volt, CLD6 Breaker<br />

SLLLS36***0CLD6<br />

450-600A c SLLLS36***0GCLD6<br />

SLLLS36***0IGCLD6<br />

M Frame 3-Pole, 600 Volt, CLD6 Breaker<br />

SLLLS36***0CMD6<br />

500-800A c SLLLS36***0GCMD6<br />

SLLLS36***0IGCMD6<br />

Ampere Catalog Ampere Catalog<br />

Rating Number Rating Number<br />

E Frame 4-Pole, 600 Volt, CED6 Breaker<br />

SLEL46***0CED6<br />

SLEL56***0CED6<br />

15-60A SLEL46***0GCED6 15-60A SLEL56***0GCED6<br />

SLEL46***0IGCED6<br />

SLEL56***0IGCED6<br />

SLEL46***0CED6<br />

SLEL56***0CED6<br />

70-100A SLEL46***0GCED6 70-100A SLEL56***0GCED6<br />

SLEL46***0IGCED6<br />

SLEL56***0IGCED6<br />

SLEL46***0CED6<br />

SLEL56***0CED6<br />

110-125A SLEL46***0GCED6 110-125A SLEL56***0GCED6<br />

SLEL46***0IGCED6<br />

SLEL56***0IGCED6<br />

F Frame 4-Pole, 600 Volt, CFD6 Breaker<br />

SLFL46***0CFD6<br />

SLFL56***0CFD6<br />

100-225A SLFL46***0GCFD6 70-200A SLFL56***0GCFD6<br />

SLFL46***0IGCFD6<br />

SLFL56***0IGCFD6<br />

SLFL462500CFD6<br />

SLFL56***0CFD6<br />

250A SLFL462500GCFD6 225-250A SLFL56***0GCFD6<br />

SLFL462500IGCFD6<br />

SLFL56***0IGCFD6<br />

J Frame 4-Pole, 600 Volt, CJD6 Breaker<br />

SLJL46***0CJD6 —<br />

200-400A c SLJL46***0GCJD6 —<br />

SLJL46***0IGCJD6 —<br />

L Frame 4-Pole, 600 Volt, CLD6 Breaker<br />

SLLLS46***0CLD6<br />

450-600A c SLLLS46***0GCLD6<br />

SLLLS46***0IGCLD6<br />

M Frame 4-Pole, 600 Volt, CLD6 Breaker<br />

SLLLS46***0CMD6<br />

500-800A c SLLLS46***0GCMD6<br />

SLLLS46***0IGCMD6<br />

E Frame 200% Neutral<br />

F Frame 200% Neutral<br />

J Frame 200% Neutral<br />

SLJL562000CJD6<br />

200A c<br />

SLJL562000GCJD6<br />

SLJL562000IGCJD6<br />

SLJLS56***0CJD6<br />

225-400A c SLJLS56***0GCJD6<br />

SLJLS56***0IGCJD6<br />

15<br />

BUSWAY SYSTEMS<br />

a Replace “***” with breaker trip rating.<br />

Example: SLEC36060ED6, for 60A trip.<br />

b All plugs shown have an IP40 rating, if IP54/55 is<br />

desired, substitute ”4” for ”0” in position 10<br />

(or 11 for cradle plugs):<br />

E Frame: Ex. SLEC360604ED6<br />

F Frame: Ex. SLFC360704FXD6<br />

J Frame: Ex. SLJC361004JXD6<br />

L Frame: Ex. SLLCS365004LXD6<br />

M Frame: Ex. SLMCS368004MXD6<br />

c 400A and larger bus plugs that require auxiliary<br />

support. See also SXSK Spring Kit.<br />

Product Category: BPLU<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-47


Sentron Circuit Breaker Bus Plugs<br />

Circuit Breaker Bus Plugs Dimensions and Weights<br />

Revised on 01/31/20<br />

Selection<br />

Circuit Breaker Bus Plugs, Dimensions and Weights (Enclosure only)<br />

Ampere<br />

Rating<br />

Dimensions Inches (mm)<br />

“A” a “B” “C” “D” max. “E” “F” “J” “K”<br />

Weight<br />

lbs (kg)<br />

125 15.13 (384) 10.18 (259) 9.75 (248) 1.60 (41) 2.50 (64) 2.50 (64) 3.50 (89) 2.25 (57) 35 (15.87)<br />

250 20.25 (514) 10.18 (259) 9.75 (248) 1.60 (41) 2.50 (64) 2.50 (64) 3.25 (83) 3.25 (83) 50 (22.68)<br />

400 21.75 (552) 16.75 (425) 11.75 (298) 1.60 (41) 5.75 (146) 5.75 (146) 4.00 (102) 3.25 (83) 83 (37.64)<br />

600 41.50 (1054) 19.75 (502) 15.75 (400) 2.31 (59) 7.00 (178) 7.75 (197) — — 130 (58.97)<br />

800 41.50 (1054) 19.75 (502) 15.75 (400) 2.31 (59) 7.00 (178) 7.75 (197) — — 177 (80.29)<br />

125 – 400A Bus Plugs<br />

15<br />

BUSWAY SYSTEMS<br />

600 – 800A Bus Plugs<br />

Circuit Breaker Bus Plugs, Load Lugs and Knockouts<br />

Frame<br />

Size<br />

Ground<br />

Lug Cu/Al<br />

Neutral Lug<br />

Cu/AI<br />

Phase Lug<br />

Cu/AI<br />

Knockout Sizes<br />

In. (mm)<br />

E Frame #14-2 #14-2 #14-1/0 7/8 (22)<br />

F Frame #14-2 #6-350 kcmil #6-350 kcmil 7/8 (22)<br />

J Frame #14-2 (2) #4-500 kcmil (2) 3/0-500 kcmil 7/8 (22)<br />

L Frame #6-350 kcmil (2) 3/0-500 kcmil (2) 3/0-500 kcmil No Knockouts<br />

M Frame #4-500 kcmil (3) #1-500 kcmil (3) #1-500 kcmil No Knockouts<br />

a Current limiting breakers add 5-7 inches to<br />

dimension A, depending upon breaker amperage.<br />

15-48<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron Circuit Breaker Bus Plugs<br />

Wall Clearance and Circuit Breaker Bus Plug Dimensions<br />

Revised on 04/30/18<br />

Selection<br />

600A and 800A Cradle Mounted<br />

30A – 400A<br />

15<br />

BUSWAY SYSTEMS<br />

Dim.<br />

Legend<br />

Circuit Breaker Plugs No Cradle<br />

E Frame<br />

Current<br />

F Frame<br />

Current<br />

J Frame<br />

Current<br />

Circuit Breaker Plugs w/Cradle<br />

L Frame<br />

Current<br />

M Frame<br />

Current<br />

Standard Limiting Standard Limiting Standard Limiting Standard Limiting Standard Limiting<br />

A 17.00 (432) 22.00 (559) 22.00 (559) 27.00 (686) 23.50 (597) 30.50 (775) 41.50 (1054) 41.50 (1054) 41.50 (1054) 41.50 (1054)<br />

B 10.25 (260) 10.25 (260) 10.25 (260) 10.25 (260) 16.75 (425) 16.75 (425) 19.75 (502) 19.75 (502) 19.75 (502) 19.75 (502)<br />

C 9.75 (248) 9.75 (248) 9.75 (248) 9.75 (248) 11.75 (298) 11.75 (298) 15.75 (400) 15.75 (400) 15.75 (400) 15.75 (400)<br />

D 12.25 (311) 12.25 (311) 12.25 (311) 12.25 (311) 18.75 (476) 18.75 (476) 20.25 (514) 20.25 (514) 20.25 (514) 20.25 (514)<br />

E 2.50 (64) 2.50 (64) 2.50 (64) 2.50 (64) 5.75 (146) 5.75 (146) 7.75 (197) 7.75 (197) 7.75 (197) 7.75 (197)<br />

F 2.50 (64) 2.50 (64) 2.50 (64) 2.50 (64) 5.75 (146) 5.75 (146) 7.00 (178) 7.00 (178) 7.00 (178) 7.00 (178)<br />

G 24.00 (610) 29.00 (737) 29.00 (737) 29.00 (737) 32.50 (826) 39.50 (1003) 41.50 (1054) 41.50 (1054) 41.50 (1054) 41.50 (1054)<br />

H 11.25 (286) 11.25 (286) 11.25 (286) 11.25 (286) 13.50 (343) 13.50 (343) 18.00 (457) 18.00 (457) 18.00 (457) 18.00 (457)<br />

J1 3.50 (89) 3.50 (89) 3.25 (83) 3.25 (83) 4.00 (102) 4.00 (102) — — — —<br />

K1 2.25 (57) 2.25(57) 3.25 (83) 3.25 (83) 3.25 (83) 3.25 (83) — — — —<br />

Legend:<br />

A = Length of enclosure including handle<br />

B = Height of enclosure<br />

C = Depth of enclosure<br />

D = Height of enclosure including optional handle location<br />

E = Extension of plug above top of busway<br />

F = Extension of plug below bottom of busway<br />

G = Cover (depth) clearance for enclosure<br />

H = Depth of enclosure from handle to edge of busway<br />

J = Knockout/ pilot hole location (horizontal)<br />

K = Knockout/ pilot hole location (vertical)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-49


15<br />

BUSWAY SYSTEMS<br />

Sentron Fusible Bus Plugs<br />

Catalog Numbering System<br />

Sentron SLVB Bus Plugs—Fusible<br />

Plug Type<br />

SL = Sentron II<br />

Heavy Duty Fusible Switch<br />

VB<br />

Orientation<br />

R = Vertical<br />

H = Horizontal<br />

Configuration (Poles/Wires)<br />

3 = 3Ø3W<br />

4 = 3Ø4W<br />

5 = 3Ø4W 200% Neutral b<br />

Voltage<br />

2 = 240V<br />

6 = 600V<br />

Max Ampere Rating<br />

1 = 30A<br />

2 = 60A<br />

3 = 100A<br />

4 = 200A<br />

5 = 400A<br />

6 = 600A<br />

IP Rating<br />

0 = IP40<br />

4 = IP55<br />

Ground Designation<br />

G = Internal Ground<br />

IG = Isolated Ground<br />

Selection / Application<br />

Watch SLVB<br />

Bus Plug<br />

installation<br />

video<br />

S L V B R 3 2 1 0 G a Revised on 06/30/18<br />

a The G and IG digits are used to specify internal and isolated ground<br />

respectively. Integral (housing) ground plugs do not require this digit.<br />

(Ex. SLID3610, SLEC360150ED6)<br />

b Available through 400A only.<br />

15-50<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron Busway Systems<br />

Fusible Bus Plugs<br />

Revised on 06/30/18<br />

Selection<br />

Fusible Bus Plugs<br />

The Sentron SLVB Bus Plug meets all<br />

UL and CSA standards to assure reliable<br />

performance in all environments.<br />

The installer and end user will appreciate<br />

new features like Highly Visible<br />

Position Indicator, Dual Stab Busway<br />

Interlocks, Dual Cover Interlocks, and<br />

Bolt-on Mounting.<br />

Sentron SLVB Fusible Bus Plugs are<br />

available in 30, 60, 100, 200, 400 and<br />

600 amp ratings (compatible with H, R,<br />

T, K and J fuses).<br />

Standard Fusible, Bus Plug Ratings<br />

Plug-In<br />

Units Series<br />

Max.<br />

Rating Fused Switch<br />

Fuse Class<br />

Fuse Kits<br />

R Fuse Kits<br />

T Fuse Kits<br />

Max. Short Circuit<br />

Current Rating<br />

SLVB_21 30A, 240V H, K, R SLR2030 — 200kA, 240V, 3ph<br />

SLVB_61 30A, 600V H, K, R, J SLR6030 — 200kA, 600V, 3ph<br />

SLVB_22 60A, 240V H, K, R SLR2060 — 200kA, 240V, 3ph<br />

SLVB_62 60A, 600V H, K, R, J SLR6060 — 200kA, 600V, 3ph<br />

SLVB_23 100A, 240V H, K, R, J, T SLR2100 SLT2100 200kA, 240V, 3ph<br />

SLVB_63 100A, 600V H, K, R, J, T SLR6100 SLT6100 200kA, 600V, 3ph<br />

SLVB_24 200A, 240V H, K, R, J, T SLR2200 SLT2200 200kA, 240V, 3ph<br />

SLVB_64 200A, 600V H, K, R, J, T SLR6200 SLT6200 200kA, 600V, 3ph<br />

SLVB_25 400A, 240V H, K, R, J, T SLR2400 SLT2400 200kA, 240V, 3ph<br />

SLVB_65 400A, 600V H, K, R, J, T SLR6400 SLT6400 200kA, 600V, 3ph<br />

SLVB_26 600A, 240V H, K, R, J, T SLR2600 SLT2600 200kA, 240V, 3ph<br />

SLVB_66 600A, 600V H, K, R, J, T SLR6600 SLT6600 200kA, 600V, 3ph<br />

15<br />

BUSWAY SYSTEMS<br />

Standard Fusible, Bus Plug Horsepower Ratings<br />

Plug-In<br />

Units Series<br />

Fused Switch<br />

Max. Rating<br />

240V, 1 ph 240V, 3 ph 480V, 3 ph 600V, 3 ph<br />

Std. Max. Std. Max. Std. Max. Std. Max.<br />

SLVB_21 30A, 240V 1.5 3.0 3.0 7.5 — — — —<br />

SLVB_61 30A, 600V — — — — 5.0 15.0 7.5 20.0<br />

SLVB_22 60A, 240V 3.0 10.0 7.5 15.0 — — — —<br />

SLVB_62 60A, 600V — — — — 15.0 30.0 15.0 50.0<br />

SLVB_23 100A, 240V 7.5 15.0 15.0 30.0 — — — —<br />

SLVB_63 100A, 600V — — — — 25.0 60.0 30.0 75.0<br />

SLVB_24 200A, 240V 15.0 — 25.0 60.0 — — — —<br />

SLVB_64 200A, 600V — — — — 50.0 125.0 60.0 150.0<br />

SLVB_25 400A, 240V 15.0 — 50.0 125.0 — — — —<br />

SLVB_65 400A, 600V — — — — 100.0 250.0 125.0 350.0<br />

SLVB_26 600A, 240V 15.0 — 75.0 200.0 — — — —<br />

SLVB_66 600A, 600V — — — — 150.0 400.0 200.0 500.0<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-51


Sentron Fusible Bus Plugs<br />

Bus Plugs / Fusible Plugs<br />

Revised on 06/30/18<br />

Selection<br />

Ampere Catalog Catalog<br />

Ampere Catalog<br />

3-Pole, 250 Volt a 4-Pole, 250 Volt, a<br />

200% Neutral a<br />

Rating Number<br />

Rating Number Number<br />

30A<br />

SLVB*3210<br />

30A SLVB*4210 SLVB*5210<br />

SLVB*3210G<br />

SLVB*4210G<br />

SLVB*5210G<br />

SLVB*3210IG<br />

SLVB*4210IG<br />

SLVB*5210IG<br />

60A<br />

SLVB*3220<br />

60A SLVB*4220 SLVB*5220<br />

SLVB*3220G<br />

SLVB*4220G<br />

SLVB*5220G<br />

SLVB*3220IG<br />

SLVB*4220IG<br />

SLVB*5220IG<br />

100A<br />

SLVB*3230<br />

100A SLVB*4230 SLVB*5230<br />

SLVB*3230G<br />

SLVB*4230G<br />

SLVB*5230G<br />

SLVB*3230IG<br />

SLVB*4230IG<br />

SLVB*5230IG<br />

200A<br />

SLVB*3240<br />

200A SLVB*4240 SLVB*5240<br />

SLVB*3240G<br />

SLVB*4240G<br />

SLVB*5240G<br />

SLVB*3240IG<br />

SLVB*4240IG<br />

SLVB*5240IG<br />

400A b<br />

SLVB*3250<br />

400A b SLVB*4250 SLVB*5250<br />

SLVB*3250G<br />

SLVB*4250G<br />

SLVB*5250G<br />

SLVB*3250IG<br />

SLVB*4250IG<br />

SLVB*5250IG<br />

600A b<br />

SLVB*3260<br />

SLVB*3260G<br />

SLVB*3260IG<br />

600A b<br />

SLVB*4260<br />

SLVB*4260G<br />

SLVB*4260IG<br />

15<br />

BUSWAY SYSTEMS<br />

Ampere Catalog Catalog<br />

Ampere Catalog<br />

3-Pole, 600 Volt a 4-Pole, 600 Volt, a<br />

200% Neutral a<br />

Rating<br />

Number<br />

Rating Number Number<br />

30A<br />

SLVB*3610<br />

30A SLVB*4610 SLVB*5610<br />

SLVB*3610G<br />

SLVB*4610G<br />

SLVB*5610G<br />

SLVB*3610IG<br />

SLVB*4610IG<br />

SLVB*5610IG<br />

60A<br />

SLVB*3620<br />

60A SLVB*4620 SLVB*5620<br />

SLVB*3620G<br />

SLVB*4620G<br />

SLVB*5620G<br />

SLVB*3620IG<br />

SLVB*4620IG<br />

SLVB*5620IG<br />

100A<br />

SLVB*3630<br />

100A SLVB*4630 SLVB*5630<br />

SLVB*3630G<br />

SLVB*4630G<br />

SLVB*5630G<br />

SLVB*3630IG<br />

SLVB*4630IG<br />

SLVB*5630IG<br />

200A<br />

SLVB*3640<br />

200A SLVB*4640 SLVB*5640<br />

SLVB*3640G<br />

SLVB*4640G<br />

SLVB*5640G<br />

SLVB*3640IG<br />

SLVB*4640IG<br />

SLVB*5640IG<br />

400A b<br />

SLVB*3650<br />

400A b SLVB*4650 SLVB*5650<br />

SLVB*3650G<br />

SLVB*4650G<br />

SLVB*5650G<br />

SLVB*3650IG<br />

SLVB*4650IG<br />

SLVB*5650IG<br />

600A b<br />

SLVB*3660<br />

600A b<br />

SLVB*4660<br />

SLVB*3660G<br />

SLVB*4660G<br />

SLVB*3660IG<br />

SLVB*4660IG<br />

Note: Replace * in catalog number with “H” for horizontal applications and “R” for riser applications.<br />

Ground Detector And<br />

Potentializer Plug<br />

Description<br />

For 2 or 3-pole<br />

240 and 480 volt<br />

service.<br />

Catalog<br />

Number<br />

SLPGR3140G<br />

Note: Available in IP40 construction only.<br />

Description<br />

Spring Kit<br />

Catalog<br />

Number<br />

SXSK<br />

Note: Used on 400A and larger bus plugs that<br />

require auxiliary support and that are mounted<br />

on vertical/riser busway. Kit contains two springs<br />

(part number 32-9909-04). One kit required per bus<br />

plug. Spring kits are automatically included when<br />

400A and larger bus plug is selected.<br />

Fuse Adapter Kits<br />

Class R Class T Class J<br />

Switch Std Fuse Catalog Catalog Catalog<br />

Rating Class Number Number Number<br />

250V<br />

30A H, K SLR2030<br />

60A H, K SLR2060<br />

100A H, K SLR2100 SLT2100<br />

200A H, K SLR2200 SLT2200<br />

400A b H, K, J SLR2400 SLT2400<br />

600A b H, K, J SLR2600 SLT2600 SLJ2600<br />

600V<br />

30A H, K, J SLR6030<br />

60A H, K, J SLR6060<br />

100A H, K, J SLR6100 SLT6100<br />

200A H, K, J SLR6200 SLT6200<br />

400A b H, K, J SLR6400 SLT6400<br />

600A b H, K, J SLR6600 SLT6600 SLJ6600<br />

a All plugs shown are rated IP40; if IP55 rating is desired,<br />

substitute a “4” for “0” in position 9.<br />

b 400A and larger bus plugs require auxiliary support. See<br />

also SXSK Spring Kit.<br />

15-52<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: BPLU


Sentron Fusible Bus Plugs<br />

Fusible Bus Plugs Dimensions and Weights<br />

Revised on 04/30/18<br />

Selection<br />

Horizontal Fusible Bus Plug Dimensions and Weighs (Enclosure Only)<br />

Ampere<br />

Rating<br />

30 13.13<br />

(333)<br />

60 13.13<br />

(333)<br />

100 13.13<br />

(333)<br />

200 14.88<br />

(377)<br />

400 18.63<br />

(473)<br />

600 18.63<br />

(473)<br />

Dimensions Inches (mm)<br />

“A” “B” “C”<br />

13.86<br />

(352)<br />

14.86<br />

(377)<br />

15.86<br />

(402)<br />

22.86<br />

(580)<br />

25.48<br />

(647)<br />

25.48<br />

(647)<br />

7.96<br />

(202)<br />

7.96<br />

(202)<br />

7.96<br />

(202)<br />

10.58<br />

(268)<br />

15.67<br />

(398)<br />

15.67<br />

(398)<br />

“D<br />

max.” “E” “F” “J” “K” “L” “M” “N” “P”<br />

2.60<br />

(66)<br />

2.60<br />

(66)<br />

2.60<br />

(66)<br />

2.60<br />

(66)<br />

5.50<br />

(140)<br />

5.50<br />

(140)<br />

6.18<br />

(156)<br />

7.18<br />

(182)<br />

8.18<br />

(207)<br />

15.88<br />

(403)<br />

12.67<br />

(322)<br />

12.67<br />

(322)<br />

2.66<br />

(67)<br />

2.66<br />

(67)<br />

2.66<br />

(67)<br />

2.66<br />

(67)<br />

7.67<br />

(195)<br />

7.67<br />

(195)<br />

2.65<br />

(67)<br />

2.65<br />

(67)<br />

2.65<br />

(67)<br />

3.40<br />

(86)<br />

12.15<br />

(309)<br />

12.15<br />

(309)<br />

2.06<br />

(52)<br />

2.06<br />

(52)<br />

2.06<br />

(52)<br />

3.06<br />

(78)<br />

3.06<br />

(78)<br />

3.06<br />

(78)<br />

9.81<br />

(249)<br />

9.81<br />

(249)<br />

9.81<br />

(249)<br />

9.81<br />

(249)<br />

11.80<br />

(299)<br />

11.80<br />

(299)<br />

6.22<br />

(157)<br />

6.22<br />

(157)<br />

6.22<br />

(157)<br />

7.95<br />

(201)<br />

9.43<br />

(239)<br />

9.43<br />

(239)<br />

5.27<br />

(134)<br />

5.27<br />

(134)<br />

5.27<br />

(134)<br />

5.27<br />

(134)<br />

11.91<br />

(303)<br />

11.91<br />

(303)<br />

8.59<br />

(218)<br />

9.59<br />

(244)<br />

10.59<br />

(269)<br />

17.59<br />

(447)<br />

15.14<br />

(385)<br />

15.14<br />

(385)<br />

Weight<br />

lbs (kg)<br />

23.5 (10.66)<br />

25.5 (11.56)<br />

28.0 (12.70)<br />

49.0 (22.22)<br />

100.0 (254)<br />

100.0 (254)<br />

Watch SLVB<br />

Bus Plug<br />

installation<br />

video<br />

15<br />

BUSWAY SYSTEMS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-53


Sentron Fusible Bus Plugs<br />

Fusible Bus Plugs Dimensions and Weights<br />

Revised on 07/07/17<br />

Selection<br />

Riser Fusible Bus Plug Dimensions and Weighs (Enclosure Only)<br />

Ampere<br />

Rating<br />

30 10.13<br />

(257)<br />

60 10.13<br />

(257)<br />

100 11.13<br />

(282)<br />

Dimensions Inches (mm)<br />

“A” “B” “C”<br />

13.86<br />

(352)<br />

14.86<br />

(377)<br />

15.86<br />

(402)<br />

7.96<br />

(202)<br />

7.96<br />

(202)<br />

7.96<br />

(202)<br />

“D<br />

max.” “E” “F” “J” “K” “L” “M” “N” “P”<br />

5.25<br />

(133)<br />

5.25<br />

(133)<br />

5.25<br />

(133)<br />

2.74<br />

(69)<br />

2.74<br />

(69)<br />

7.74<br />

(196)<br />

2.36<br />

(59)<br />

2.36<br />

(59)<br />

3.36<br />

(85)<br />

2.65<br />

(67)<br />

2.65<br />

(67)<br />

2.65<br />

(67)<br />

2.06<br />

(52)<br />

2.06<br />

(52)<br />

2.06<br />

(52)<br />

8.06<br />

(204)<br />

8.06<br />

(204)<br />

8.06<br />

(204)<br />

5.08<br />

(129)<br />

2.08<br />

(52)<br />

6.08<br />

(154)<br />

7.8<br />

(198)<br />

7.8<br />

(198)<br />

7.8<br />

(198)<br />

6.06<br />

(154)<br />

7.06<br />

(179)<br />

8.06<br />

(205)<br />

Weight<br />

lbs (kg)<br />

23.5 (10.66)<br />

25.5 (11.56)<br />

28.0 (12.70)<br />

Watch SLVB<br />

Bus Plug<br />

installation<br />

video<br />

200 14.88<br />

(377)<br />

22.86<br />

(580)<br />

10.58<br />

(268)<br />

5.90<br />

(149)<br />

5.11<br />

(129)<br />

4.74<br />

(120)<br />

3.40<br />

(86)<br />

3.06<br />

(78)<br />

10.42<br />

(264)<br />

7.35<br />

(186)<br />

9.05<br />

(230)<br />

13.81<br />

(351)<br />

49.0 (22.22)<br />

400 18.63<br />

(473)<br />

25.48<br />

(647)<br />

15.67<br />

(398)<br />

5.50<br />

(140)<br />

6.60<br />

(167)<br />

7.10<br />

(180)<br />

12.15<br />

(309)<br />

3.06<br />

(78)<br />

11.97<br />

(304)<br />

9.25<br />

(234)<br />

13.56<br />

(344)<br />

13.49<br />

(342)<br />

100.0 (2540)<br />

600 18.63<br />

(473)<br />

25.48<br />

(647)<br />

15.67<br />

(398)<br />

5.50<br />

(140)<br />

6.60<br />

(167)<br />

7.10<br />

(180)<br />

12.15<br />

(309)<br />

3.06<br />

(78)<br />

11.97<br />

(304)<br />

9.25<br />

(234)<br />

13.56<br />

(344)<br />

13.49<br />

(342)<br />

100.0 (2540)<br />

BUSWAY SYSTEMS<br />

15<br />

Fusible Switch Plug, Load Lugs, and Knockouts<br />

Ampere<br />

Rating<br />

Ground Lug<br />

Cu/Al<br />

Neutral Lug<br />

Cu/Al<br />

Phase Lug<br />

Cu/Al<br />

30 #14-1/0 #14-2 #14-2 7/8 (22)<br />

60 #14-1/0 #14-1/0 #14-2 7/8 (22)<br />

100 #14-1/0 #14-1/0 #14-1/0 7/8 (22)<br />

200 #14-1/0 #6-300MCM #6-300MCM 7/8 (22)<br />

400 (2)#6-350MCM (2) 1/0-250MCM or<br />

(1) 1/0-750MCM<br />

600 (2)#6-350MCM (4) 1/0-250MCM or<br />

(2) 1/0-750MCM<br />

(2) 1/0-250MCM or<br />

(1) 1/0-750MCM<br />

(4) 1/0-250MCM or<br />

(2) 1/0-750MCM<br />

Knockout Sizes Inches (mm)<br />

7/8 (22)<br />

7/8 (22)<br />

15-54<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron Fusible Bus Plugs<br />

Wall Clearance and Fusible Bus Plug Dimensions<br />

Revised on 04/30/18<br />

Dimensions<br />

Wall Clearance and Bus Plug Dimensions<br />

Horizontal (Inches/mm)<br />

Dim. 30 60 100 200 400 600<br />

A 13.13 13.13 13.13 14.88 18.63 18.63<br />

(333) (333) (333) (377) (473) (473)<br />

B 13.86 14.86 15.86 22.86 27.00 27.00<br />

(352) (377) (402) (580) (686) (686)<br />

C 7.96 7.96 7.96 10.58 15.67 15.67<br />

(202) (202) (202) (268) (398) (398)<br />

D 15.89 16.68 17.68 24.66 20.00 20.00<br />

(403) (423) (449) (626) (508) (508)<br />

E 6.19 7.19 8.19 15.19 12.67 12.67<br />

(157) (182) (208) (385) (322) (322)<br />

F 2.67 2.67 2.67 2.67 7.67 7.67<br />

(67) (67) (67) (67) (195) (195)<br />

G 20.39 20.39 20.39 24.76 33.75 33.75<br />

(517) (517) (517) (628) (857) (857)<br />

H 13.09 13.09 13.09 16.55 21.17 21.17<br />

(332) (332) (332) (420) (538) (538)<br />

J 2.65 2.65 2.65 3.40 12.15 12.15<br />

(67) (67) (67) (86) (309) (309)<br />

K 2.06 2.06 2.06 3.06 3.06 3.06<br />

(52) (52) (52) (78) (78) (78)<br />

L 2.65 2.65 2.65 2.65 2.65 2.65<br />

(67) (67) (67) (67) (67) (67)<br />

M 15.07 15.07 15.07 16.82 21.00 21.00<br />

(382) (382) (382) (427) (533) (533)<br />

Wall Clearance and Bus Plug Dimensions<br />

Riser (Inches/mm)<br />

Watch SLVB<br />

Bus Plug<br />

installation<br />

video<br />

15<br />

BUSWAY SYSTEMS<br />

Dim. 30 60 100 200 400 600<br />

A 10.13 10.13 11.13 14.68 18.63 18.63<br />

(237) (257) (282) (372) (473) (473)<br />

B 13.86 14.86 15.86 22.86 27.00 27.00<br />

(352) (377) (402) (580) (686) (686)<br />

C 7.96 7.96 7.96 10.58 15.67 15.67<br />

(202) (202) (202) (268) (398) (398)<br />

D 15.89 16.68 17.68 24.66 20.00 20.00<br />

(403) (423) (449) (626) (508) (508)<br />

E 2.74 2.74 7.74 5.11 6.60 6.60<br />

(69) (69) (196) (129) (167) (167)<br />

F 2.36 2.36 3.36 4.74 7.10 7.10<br />

(59) (59) (85) (120) (180) (180)<br />

G 17.39 17.39 18.39 24.76 33.75 33.75<br />

(441) (441) (467) (628) (857) (857)<br />

H 13.09 13.09 13.09 16.55 21.17 21.17<br />

(332) (332) (332) (420) (538) (538)<br />

J 2.65 2.65 2.65 3.40 12.15 12.15<br />

(67) (67) (67) (86) (309) (309)<br />

K 2.06 2.06 2.06 3.06 3.06 3.06<br />

(52) (52) (52) (78) (78) (78)<br />

L 3.55 3.55 3.55 3.55 2.65 2.65<br />

(90) (90) (90) (90) (67) (67)<br />

M 12.07 12.07 13.07 16.82 21.00 21.00<br />

(306) (306) (331) (427) (533) (533)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-55


Sentron SPD Bus Plugs<br />

Sentron SPD Bus Plugs<br />

Revised on 06/30/18<br />

Technical<br />

15<br />

BUSWAY SYSTEMS<br />

The Siemens advantage...<br />

Siemens history of innovation and<br />

safety continues with our line of UL<br />

1449 4th Edition SPD’s. The TPS Series<br />

utilizes thermally protected MOV’s<br />

specifically designed for safe operation<br />

in high fault current or sustained<br />

overvoltage conditions that can cause<br />

other SPD’s to fail in an unsafe manner<br />

and damage other equipment in the<br />

distribution system. Every MOV, including<br />

N-G, is monitored. Indicator lights<br />

for each phase provide indication of<br />

loss of protection and phase loss protection.<br />

The direct bus, integral design<br />

reduces circuit impedance resulting in<br />

the lowest possible let-through voltages<br />

providing maximum protection to facility<br />

equipment and systems.<br />

All TPS Series SPD’s:<br />

• UL 1449 4th Edition Listed, CUL, CE<br />

Mark<br />

• Designed, tested, manufactured to<br />

ANSI/IEEE C62.42.1 – 2002, C62.41.2<br />

– 2002, C62.45 – 2002<br />

• Provide indication of loss of protection<br />

on each phase and phase loss<br />

• Include all UL-required over current<br />

protection and safety coordination<br />

inside<br />

• Prevent internally generated surges<br />

from propagating throughout a facility<br />

and externally generated surges from<br />

reaching sensitive loads<br />

Low Exposure Applications – TPS3 09<br />

n 100kA per phase<br />

• 200kA SCCR<br />

• 20kA nominal discharge current<br />

• Indicator lights standard<br />

• Individually fused, thermally protected MOV’s<br />

• Dry contacts and audible alarm optional<br />

Medium Exposure Applications – TPS3 01<br />

• 100kA – 300kA per phase<br />

• 200kA SCCR<br />

• 20kA nominal discharge current<br />

• Indicator lights, audible alarm and dry contacts standard<br />

• Individually fused, thermally protected MOV’s<br />

• EMI/RFI filtering<br />

• Surge counter optional<br />

High Exposure Applications – TPS3 06<br />

• 400kA – 500kA per phase<br />

• 200kA SCCR<br />

• 20kA nominal discharge current<br />

• Indicator lights, audible alarm and dry contacts standard<br />

• Individually fused, thermally protected MOV’s<br />

• EMI/RFI filtering<br />

• Surge counter optional<br />

Watch SLVB<br />

Bus Plug<br />

installation<br />

video<br />

15-56<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron SPD Bus Plugs<br />

Sentron SPD Bus Plugs<br />

Revised on 01/31/20<br />

Catalog Number Logic<br />

Sentron SPD Bus Plug Numbering System<br />

Plug Type<br />

STP = Sentron SPD VBII<br />

Orientation<br />

HF = Horizontal Fused (standard)<br />

R = Riser d<br />

Configuration (Poles/Wires)<br />

3 = 3Ø 3W<br />

4 = 3Ø 4W<br />

IP Rating<br />

4 = IP55<br />

Ground Designation<br />

G = Internal Ground<br />

Voltage Code<br />

A = 120/240V 1Ø 3W<br />

B = 240/120V 3Ø 4W<br />

D = 240V 3Ø 3W<br />

E = 480Y/277V 3Ø 4W<br />

F = 480V 3Ø 3W<br />

G = 600V 3Ø 3W<br />

L = 600Y/347V 3Ø 4W<br />

TPS Model Number<br />

01 = TPS3 01 c<br />

1L = TPS3 L1 (10 Mode) ac<br />

06 = TPS3 06 c<br />

6L = TPS3 L6 (10 Mode) ac<br />

09 = TPS3 09 b<br />

Surge Current (kA)<br />

10 = 100kA per Phase TPS3 01, TPS3 09<br />

15 = 150kA per Phase TPS3 L1<br />

20 = 200kA per Phase TPS3 01<br />

25 = 250KA per phase TPS3 01<br />

30 = 300kA per Phase TPS3 01, TPS3 L1<br />

40 = 400kA per Phase TPS3 06<br />

45 = 450kA per Phase TPS3 L6<br />

50 = 500kA per Phase TPS3 06<br />

Options<br />

TPS3 01 and TPS3 06:<br />

R = Remote Monitor<br />

X = Surge Counter<br />

TPS 9:<br />

D = Dry Contact & Audible Alarm<br />

S T P H F 4 4 G E 0 6 4 0 X<br />

Watch SLVB<br />

Bus Plug<br />

installation<br />

video<br />

15<br />

BUSWAY SYSTEMS<br />

Notes:<br />

a The 10 mode devices provide additional circuit protection for Line to Neutral and Neutral to Ground. The 10 modes of protection are:<br />

L1-G, L2-G, L3-G, L1-L2, L2-L3, L1-L3, L1-N, L2-N, L3-N, N-G.<br />

b Standard features: indicator lights.<br />

c Standard features: indicator lights, dry contacts, audible alarm with silence switch, test button.<br />

d In riser applications, Sentron SPD Bus Plug Numbering System only requires the "R" character.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-57


Sentron SPD Bus Plugs<br />

Sentron SPD Bus Plugs<br />

Revised on 06/30/18<br />

Technical<br />

Horizontal SPD bus plugs dimensions and weights<br />

Plug type<br />

Dimensions inches (mm)<br />

“A” “B” “C” “D” max. “E” “F” Weight lbs. (kgs)<br />

TPS 9 13.30 (336) 15.86 (403) 7.44 (189) 2.60 (66) 8.17 (208) 2.66 (67) 30 (13.63)<br />

TPS 1 19.30 (490) 11.77 (299) 8.50 (216) 2.60 (66) 4.08 (104) 2.66 (67) 35 (15.90)<br />

TPS 6 19.30 (490) 11.77 (299) 8.50 (216) 2.60 (66) 4.08 (104) 2.66 (67) 38 (17.27)<br />

Watch SLVB<br />

Bus Plug<br />

installation<br />

video<br />

15<br />

BUSWAY SYSTEMS<br />

Riser SPD bus plugs dimensions and weights<br />

Plug type<br />

Dimensions inches (mm)<br />

“A” “B” “C” “D” max. “E” “F” Weight lbs. (kgs)<br />

TPS 9 10.25 (260) 13.86 (352) 7.96 (202) 5.25 (133) 2.74 (69) 2.36 (59) 25 (11.36)<br />

TPS 1 11.25 (286) 19.36 (492) 7.96 (202) 5.25 (133) 7.74 (196) 3.36 (85) 35 (15.90)<br />

TPS 6 15.00 (381) 22.86 (580) 10.58 (268) 5.25 (133) 5.11 (129) 4.74 (120) 45 (20.45)<br />

15-58<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Sentron 3/6 Bus Plugs<br />

Sentron 3/6 Bus Plugs<br />

Revised on 04/30/18<br />

Technical<br />

Product Overview<br />

The Sentron 3/6 bus plug is designed for light industrial,<br />

commercial, and datacenter applications. Optional factory<br />

installed receptacles range from 10 to 100A per pole, and<br />

the bus plug allows for anywhere between 1 and 6 poles of<br />

distribution (i.e. two 3Ø receptacles per plug). This product<br />

combines plug-and-play capabilities, minimizing installation<br />

time and cost, with the option for preconfigured embedded<br />

branch circuit metering utilizing SEM3.<br />

Product Application<br />

Building your metered network of Sentron 3/6 bus plugs is<br />

easy. There are two variations of metered bus plugs, simple<br />

meter plugs (child) and controller plugs (parent). Each SEM3<br />

controller can monitor 42 bus plug poles. Depending on the<br />

number of metered poles per bus plug, one parent controller<br />

plug can monitor between 6 to 41 bus plugs. An example of<br />

a network of seven 6-pole bus plugs is shown below (in this<br />

case there is one controller and six metered plugs). Outputs<br />

from multiple controller plugs may be consolidated at an<br />

Ethernet switch (shown below) or integrated directly into a<br />

building or site management system.<br />

Metered Bus Plug 1 Metered Bus Plug 2 Metered Bus Plug 3 Controller Bus Plug 1 Metered Bus Plug 4 Metered Bus Plug 5 Metered Bus Plug 6<br />

15<br />

600V Isolated<br />

Siemens Cable<br />

Controller Bus Plug 2<br />

600V Isolated<br />

Siemens Cable<br />

600V Isolated<br />

Siemens Cable<br />

600V Isolated<br />

Siemens Cable<br />

600V Isolated<br />

Siemens Cable<br />

8 Port Ethernet Switch<br />

600V Isolated<br />

Siemens Cable<br />

BUSWAY SYSTEMS<br />

CAT6 Cable<br />

CAT6 Cable<br />

CAT6 Cable<br />

Controller Bus Plug 3<br />

The function of the Ethernet switch is to aggregate signals being<br />

generated by each SEM3 controller. Each SEM3 controller bus plug may<br />

monitor up to 42 poles. Metered bus plugs may have between 1 and 6<br />

metered poles. SEM3 may also be embedded in other electrical<br />

equipment such as switchboards or panels, providing a comprehensive<br />

power monitoring solution.<br />

Power Monitoring System/Building<br />

Management System/SCADA<br />

CAT6 Cable<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-59


Sentron 3/6 Bus Plugs<br />

Catalog Numbering System<br />

Revised on 04/30/18<br />

Selection / Application<br />

Sentron 3/6 Bus Plugs—Circuit Breaker (Installed)<br />

B P S A 1 A 0 A 1 A 0 0 N N<br />

Prefix<br />

BP = Bus Plug<br />

Type<br />

S = Sentron<br />

Enclosure<br />

A =13 x 10in (60A max branch, corded receptacle)<br />

C = 13 x 14in (60A max branch, flush mount receptacle)<br />

D = 13 x 14in (100A max branch, any receptacle)<br />

System Configuration<br />

1 = 3Ø<br />

2 = 3Ø + Internal Grd<br />

3 = 3Ø + Isolated Grd<br />

5 = 3Ø + Neutral<br />

6 = 3Ø + Neutral + Internal Grd<br />

7 = 3Ø + Neutral + Isolated Grd<br />

9 = 3Ø + 200% Neutral<br />

0 = 3Ø + 200% Neutral + Internal Grd<br />

Z = 3Ø + 200%<br />

15<br />

BUSWAY SYSTEMS<br />

Color<br />

A = Graphite<br />

G = ANSI 61<br />

X = Other<br />

Connection Type<br />

0 = Enclosure Only<br />

1 = Breaker Only<br />

2 = Flush Mount Receptacle<br />

3 = 3ft Corded Connector<br />

4 = 5ft Corded Connector<br />

5 = 7ft Corded Connector<br />

6 = 10ft Corded Connector<br />

7 = Custom<br />

Number of Circuits and Phasing<br />

A1-D4<br />

Breaker Frame<br />

A = BL<br />

B = BLH<br />

C = HBL<br />

D = BQD<br />

E = NGB<br />

Device Amps<br />

00 = No Breaker<br />

9A = 10A<br />

9B = 15A<br />

9C = 20A<br />

9D = 25A<br />

9E = 30A<br />

9F = 35A<br />

9G = 40A<br />

9H = 45A<br />

9J = 50A<br />

9K = 60A<br />

9L = 70A<br />

9M = 80A<br />

9N = 90A<br />

9P = 100A<br />

Metering System<br />

N = None<br />

C = SEM3 Controller<br />

M = SEM3 Meter Only<br />

Meter Type<br />

N = None<br />

G = 3 Meter Rack, Low Accuracy Meters<br />

H = 3 Meter Rack, High Accuracy Meters<br />

X = 6 Meter Rack, Low Accuracy Meters<br />

Y = 6 Meter Rack, High Accuracy Meters<br />

15-60<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


0<br />

0<br />

Sentron 3/6 Bus Plugs<br />

Rev<br />

Third<br />

Angle<br />

Proj<br />

0<br />

Revised on 04/30/18<br />

Sentron 3/6 Bus Plugs<br />

Sht<br />

421799 1<br />

Technical<br />

Product Configurations<br />

Field Wire-able Bus Plug<br />

n Enclosure height of 14.20"<br />

n Customer supplied receptacle or corded connector<br />

Third<br />

n Stocking program for specific variants<br />

Dwg. No.<br />

421799<br />

Angle<br />

Proj<br />

E<br />

C<br />

Field Wire-able Bus Plug<br />

A<br />

Non-Metered Bus Plug<br />

n Standard enclosure height of 10.18" at 60A (per pole) and below<br />

n Enclosure height of 14.20" for all surface mounted receptacle variants<br />

D<br />

n Factory installed corded or surface mount receptacles/connectors<br />

Metered Bus Plug<br />

n Standard enclosure height of 10.18" at 60A (per pole) and below<br />

n Enclosure height of 14.20" for all surface mounted receptacle variants<br />

n Factory installed corded or surface mount receptacles/connectors<br />

E<br />

n Preconfigured SEM3 meter rack (child)<br />

Controller Bus Plug<br />

n Standard enclosure height of 10.18" at 60A (per pole) and below<br />

n Enclosure height of 14.20" for all surface mounted receptacle variants<br />

n Factory installed corded or surface mount receptacles/connectors<br />

D<br />

n Preconfigured SEM3 meter rack and controller (parent)<br />

Product Configurations<br />

Circuit<br />

Siemens Breaker Frames<br />

Load Connection<br />

Branch Circuit Metering<br />

(SEM3)<br />

• 1-6 poles of distribution<br />

• 10-100A per pole<br />

• 100 and 200% neutral options<br />

BL, BLH, HBL, BQD, NGB,<br />

• Field wired (with KO's), no receptacles<br />

• Surface or flush mount receptacles<br />

• Corded Connector(s) or receptacle(s) at 3, 5, 7, or 10 ft<br />

• Meter only lug or meter and controller plug<br />

• 3 and 6 meter racks available<br />

• Low (1%) and high (.2%) accuracy meters available<br />

Filename:<br />

Model Name: 421750<br />

Dwg. No.<br />

Sht Rev<br />

Model Name: 421750 0<br />

Filename:<br />

421799<br />

421799 3<br />

Non-Metered Bus Plug<br />

C<br />

A<br />

REPRESENTATIVE OF SENTRON BPSC & BPSD W/O CONTROLLER<br />

B<br />

B<br />

Metered Bus Plug<br />

REPRESENTATIVE OF SENTRON BPSA W/O CONTROLLER<br />

A<br />

B<br />

3B-542T 5/9/2016<br />

Rev ECN Date<br />

- Denotes latest changes<br />

Q - Critical Dimension<br />

.XX<br />

.XXX<br />

Angular<br />

15<br />

Unless otherwise sp<br />

dimensions are in in<br />

.<br />

Tolerances are nonand<br />

are as follows u<br />

specified otherwise.<br />

Do not scal<br />

Dwn S. PEVER<br />

Chk SEP<br />

Apvd SEP<br />

BUSWAY SYSTEMS<br />

3B-542T 5/9/2016<br />

Date<br />

Rev ECN<br />

I<br />

- Denotes latest changes<br />

- Critical Dimension<br />

H<br />

E<br />

C<br />

Controller Bus Plug<br />

A<br />

H<br />

B<br />

D<br />

10.18<br />

I<br />

6.61<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-61<br />

REPRESENTATIVE OF BPSA W/CONTROLLER


0<br />

Q<br />

Sentron 3/6 Bus Plugs<br />

Sentron 3/6 Bus Plugs<br />

Technical<br />

Corded Bus Plug (Non-Metered and Metered) Dimensions and Weights<br />

Ampere<br />

Rating<br />

Dimensions inches (mm)<br />

“A” “B” “C” “D”. “E” “F” “G” “H” “I”<br />

Weight lbs.<br />

(kgs)*<br />

10-60A 13.21 (336) 10.18 (259) 7.64 (194) 4.12 (105) 1.03 (26) 6.93 (176) 6.29 (160) 3.55 (90) 6.64 (169) 21 (9.52)<br />

70-100A 13.21 (336) 14.20 (361) 7.64 (194) 8.12 (206) 1.03 (26) 6.93 (176) 6.29 (160) 3.55 (90) 10.64 (270) 23 (10.43)<br />

*Approximate weight without cord of heaviest plug in amperage range.<br />

Third<br />

Angle<br />

Proj<br />

15<br />

BUSWAY SYSTEMS<br />

Corded Bus Plug (Controller) Dimensions and Weights<br />

Ampere<br />

Rating<br />

Dwg. No.<br />

Sht Rev<br />

Filename:<br />

Model Name: 421750 421799<br />

0<br />

421799 3<br />

D<br />

E<br />

Dimensions inches (mm)<br />

“A” “B” “C” “D”. “E” “F” “G” “H” “I”<br />

Weight lbs.<br />

(kgs)*<br />

10-60A 17.64 (448) 10.20 (259) 7.64 (194) 4.12 (105) 1.03 (26) 6.93 (176) 10.71 (272) 3.55 (90) 6.64 (169) 29 (13.15)<br />

70-100A 17.64 (448) 14.20 (361) 7.64 (194) 8.12 (206) 1.03 (26) 6.93 (176) 10.71 (272) 3.55 (90) 10.64 (270) 31 (14.06)<br />

*Approximate weight without cord of heaviest plug in amperage range.<br />

C<br />

B<br />

REPRESENTATIVE OF SENTRON BPSA W/O CONTROLLER<br />

A<br />

5/9/2016<br />

3B-542T<br />

I<br />

Rev ECN Date<br />

- Denotes latest changes<br />

- Critical Dimension<br />

H<br />

.XX<br />

.XXX<br />

Angular<br />

Dwn<br />

Chk<br />

Apvd<br />

F<br />

Unless otherwise specified<br />

dimensions are in inches<br />

.<br />

Tolerances are non-cumulative<br />

and are as follows unless<br />

specified otherwise.<br />

.02<br />

.005<br />

Do not scale drawing<br />

S. PEVER Date 05/09/16<br />

SEP Date 05/09/16<br />

SEP Date 05/09/16<br />

2<br />

Dwg No<br />

Scale<br />

OF PLUG IN BASE<br />

G<br />

Confidential Property of<br />

Siemens Industry, Inc.<br />

DIMENSION DRAWING<br />

SENTRON 3/6 BUS PLUGS<br />

SENTRON BUSWAY<br />

421799<br />

1.000<br />

Sheet<br />

3<br />

of<br />

4<br />

Rev<br />

0<br />

OF PLUG IN BASE<br />

E<br />

C<br />

A<br />

F<br />

G<br />

H<br />

B<br />

D<br />

10.18<br />

I<br />

6.61<br />

15-62<br />

REPRESENTATIVE OF BPSA W/CONTROLLER<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Surface Mount Receptacle Bus Plug (Non-Metered and Metered) Dimensions and Weights<br />

Ampere<br />

Rating<br />

Dimensions inches (mm)<br />

“A” “B” “C” “D”. “E” “F” “G” “H” “I”<br />

Weight lbs.<br />

(kgs)*<br />

10-100A 13.21 (336) 14.20 (361) 7.64 (194) 8.12 (206) 1.03 (26) 6.93 (176) 6.29 (160) 3.55 (90) 10.64 (270) 23 (10.43)<br />

*Approximate weight without cord of heaviest plug in amperage range.<br />

Third<br />

Angle<br />

Proj<br />

421799<br />

Sht<br />

421799 1<br />

Rev<br />

0<br />

Q<br />

0<br />

0<br />

Sentron 3/6 Bus Plugs<br />

Sentron 3/6 Bus Plugs<br />

Technical<br />

Dwg. No.<br />

E<br />

C<br />

A<br />

F<br />

OF PLUG IN BASE<br />

G<br />

H<br />

Filename:<br />

D<br />

B<br />

I<br />

15<br />

Surface Mount Receptacle Bus Plug (Controller) Dimensions and Weights<br />

Model Name: 421750<br />

Ampere<br />

Rating<br />

REPRESENTATIVE OF SENTRON BPSC & BPSD W/O CONTROLLER<br />

Dimensions inches (mm)<br />

“A” “B” “C” “D”. “E” “F” “G” “H” “I”<br />

0<br />

Weight lbs.<br />

(kgs)*<br />

10-100A 17.64 (448) 14.20 (361) 7.64 (194) 8.12 (206) 1.03 (26) 6.93 (176) 10.71 (272) 3.55 (90) 10.64 (270) 33 (14.97)<br />

*Approximate weight without cord of heaviest plug in amperage range.<br />

5/9/2016<br />

3B-542T<br />

Date<br />

ECN<br />

Rev<br />

- Denotes latest changes<br />

- Critical Dimension<br />

Q<br />

Unless otherwise specified<br />

dimensions are in inches<br />

.<br />

Tolerances are non-cumulative<br />

and are as follows unless<br />

specified otherwise.<br />

.XX<br />

.XXX<br />

Angular<br />

Dwn<br />

Chk<br />

Apvd<br />

0.02<br />

0.005<br />

Do not scale drawing<br />

S. PEVER Date 05/09/16<br />

SEP Date 05/09/16<br />

SEP Date 05/09/16<br />

2<br />

Dwg No<br />

Scale<br />

Confidential Property of<br />

Siemens Industry, Inc.<br />

DIMENSION DRAWING<br />

SENTRON 3/6 BUS PLUGS<br />

SENTRON BUSWAY<br />

421799<br />

1.000<br />

Sheet<br />

1<br />

of<br />

4<br />

Rev<br />

BUSWAY SYSTEMS<br />

Third<br />

Angle<br />

Proj<br />

Dwg. No.<br />

Sht Rev<br />

Filename:<br />

Model Name: 421750 421799<br />

0<br />

421799 2<br />

D<br />

E<br />

C<br />

A<br />

10.20<br />

B<br />

4.00<br />

REPRESENTATIVE OF BPSC & BPSD W/CONTROLLER<br />

OF PLUG IN BASE<br />

F<br />

G<br />

H<br />

I<br />

5/9/2016<br />

Date<br />

Unless otherwise specified<br />

dimensions are in inches<br />

Confidential Property of<br />

.<br />

Siemens Industry, Inc.<br />

Tolerances are non-cumulative<br />

and are as follows unless<br />

specified otherwise.<br />

DIMENSION DRAWING<br />

.XX<br />

.02<br />

Siemens Industry, Inc. .XXX SPEEDFAX .005 SENTRON Product 3/6 Catalog BUS PLUGS15-63<br />

3B-542T<br />

ECN<br />

Rev<br />

- Denotes latest changes<br />

- Critical Dimension<br />

Angular<br />

2<br />

Do not scale drawing<br />

Dwn<br />

Dwg No<br />

S. PEVER Date 05/09/16<br />

Chk SEP Date 05/09/16<br />

Apvd<br />

Date<br />

Scale<br />

SEP<br />

05/09/16<br />

SENTRON BUSWAY<br />

421799<br />

1.000<br />

Sheet 2 of 4<br />

Rev<br />

0


XJ-L HD Busway System<br />

Revised on 04/30/18<br />

XJ-L HD Busway Introduction<br />

XJ-L HD Busway is available up to 400A. XJ-L Busway is the<br />

leading power distribution solution for demanding applications<br />

that require reliable, high quality power. XJ-L HD Busway is<br />

the optimal choice for both contractors and users concerned<br />

with designing superior electrical systems that require a high<br />

plug density and optimal space utilization.<br />

15<br />

BUSWAY SYSTEMS<br />

Competitive advantages:<br />

• Compact size – small cross section for applications where<br />

busway routing is constrained<br />

• Joint Connection – dual spring clamp assemblies ensure<br />

reliable, maintenance-free joints<br />

• Safety – plug-in outlets are IP2X finger safe<br />

• Reliability – fundamental design has a 60 year history of<br />

reliability<br />

• Service – simple snap together installation, maintenance<br />

free joints, factory stock of critical components and large<br />

distribution inventory of bus plugs ensure quick and easy<br />

serviceability<br />

• Fittings – elbow, tee, crosses, flanged end, and tap boxes<br />

are offered in standard and custom configurations<br />

• Compatibility – the full range of XJ-L HD bus plugs are<br />

interchangeable between 100A, 225A and 400A busway<br />

Key features:<br />

• Up to twelve 100A bus plugs can be installed per 10’ of<br />

plug-in busway. Plug-in busway can be configured with six<br />

plug-in openings per side (standard) or twelve on one side<br />

(high density).<br />

• Bus plugs are readily installed on energized busway and<br />

are fully interchangeable between 100, 225 and 400A<br />

configurations.<br />

• Bus plugs are available with fusible or circuit breaker<br />

disconnects, configured with a wide variety of optional<br />

receptacles, branch circuit breakers, drop cords, etc.<br />

• Bus bars are solid copper (98% conductivity) and tin plated<br />

for superior electrical performance and corrosion resistance<br />

(optional silver plating is also available). The solid bus bar<br />

design provides superior short circuit strength (up to 35 kA)<br />

compared to channel style conductors and cable.<br />

• Totally enclosed steel housing is robust, guarding against<br />

incidental contact and contamination of live parts. Enclosed<br />

box design will not twist or distort during bus plug<br />

installation.<br />

• Installation is fast and easy. Joint connections simply snap<br />

together without special tools, housing couplers, or bus<br />

connectors.<br />

• Suitable for horizontal and vertical mounting and under-the<br />

floor applications.<br />

15-64<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


XJ-L HD Busway System<br />

XJ-L HD Busway Overview<br />

XJ-L HD Busway<br />

XJ-L HD Busway is well known for its<br />

outstanding performance, providing<br />

convenient, cost-effective power distribution<br />

for high-tech environments, data<br />

centers, laboratories, and other applications<br />

requiring consistent, quality<br />

power distribution. Key XJ-L HD design<br />

features include optional isolated<br />

ground or 200% neutral across entire<br />

product range.<br />

As a result, XJ-L HD Busway is an intelligent<br />

choice for contractors and users<br />

concerned with designing superior electrical<br />

distribution systems. The compact<br />

design is ideal for limited working areas<br />

in critical power, manufacturing, laboratory<br />

test facilities, schools, hospitals,<br />

and machine shops.<br />

With XJ-L HD Busway, you get an<br />

exclusive, optional isolated ground<br />

design that ensures clean power. Unlike<br />

bonded ground designs that may convey<br />

surges from one electrical devce to<br />

another, the XJ-L HD optional isolated<br />

ground system is well suited for critical<br />

power environments. The ground bar is<br />

the same size as the phase bars, with<br />

the same ampere rating. Installation is<br />

easy, joining one XJ-L HD Busway section<br />

to another is as simple as matching<br />

ends and snapping them together.<br />

Bus bars are held securely in place by<br />

spring pressure clips located in the joint<br />

insulator. The joint is secured when<br />

the external housing plate is attached<br />

with captive screws. Thanks to built-in<br />

flexibility and a low initial cost, you also<br />

benefit from future savings when you<br />

need new equipment.<br />

Time to add on busway for new or<br />

expanded facilities? The XJ-L Busway<br />

you installed years ago matches the<br />

XJ-L HD Busway you specify today and<br />

years from now the new busway sections,<br />

components or system-compatible<br />

bus plugs will still fit.<br />

Dependability<br />

With over one million feet in service,<br />

XJ-L HD Busway has a proven track<br />

record. The busway joints are easy to<br />

install and maintenance free. Solid copper<br />

bus bars and totally enclosed steel<br />

housings are designed for decades of<br />

dependable service.<br />

Flexibility<br />

Siemens XJ-L HD Busway is available<br />

in a wide variety of straight lengths,<br />

elbows, tees, crosses, and tap boxes<br />

that can be installed and then readily<br />

expanded or reconfigured to meet<br />

changing requirements. Custom fittings<br />

and straight lengths can be engineered<br />

to tailor the busway system to application-specific<br />

customer requirements.<br />

Bus Plugs can be installed, then relocated<br />

as required without de-energizing<br />

the busway. All XJ-L HD Bus Plugs are<br />

fully interchangeable with all XJ-L HD<br />

Busway configurations.<br />

Cost<br />

Siemens XJ-L HD Busway offers a<br />

lower cost solution, compared to cable<br />

and conduit, sandwich style busway<br />

or even light duty track busway. Snap<br />

together installation requires no special<br />

tools and is fast, easy and maintenance<br />

free. Solid, highly conductive bus bars<br />

minimize electrical losses and ensure<br />

long-term energy savings.<br />

Equipment protection<br />

Critical equipment is protected via<br />

fuse or circuit breaker plugs. Due to<br />

their proximity, the plugs provide a<br />

localized method of protection and<br />

isolated disconnection.<br />

Space<br />

Space in critical power/data center facilities<br />

is at a premium. XJ-L HD Busway<br />

requires less space than conventional<br />

power distribution methods such as<br />

cable and conduit.<br />

Availability<br />

XJ-L HD plugs are stocked to meet<br />

your quick-ship requirements. Once<br />

you factor in all the advantages, XJ-L<br />

HD is clearly the best choice for reliable,<br />

flexible, and economical power<br />

distribution for data centers, light industrial,<br />

and high tech applications.<br />

15<br />

BUSWAY SYSTEMS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-65


XJ-L HD Busway System<br />

Revised on 04/30/18<br />

XJ-L HD Busway Specifications<br />

15<br />

BUSWAY SYSTEMS<br />

XJ-L HD Busway is available in 100A,<br />

225A and 400A ratings making it the<br />

right choice for light industrial and commercial<br />

applications where low initial<br />

startup and maintenance costs are prerequisites.<br />

XJ-L HD Busway is the most<br />

logical choice for high tech, data intensive<br />

environments, especially when<br />

isolated ground is required.<br />

Housing<br />

XJ-L HD Busway features a totally<br />

enclosed, non-ventilated, steel housing.<br />

The housing is covered with an electrostatically<br />

applied polyester urethane<br />

powder paint. Choice of colors: ASA#61<br />

Gray or Graphite Gray. The paint is<br />

scratch resistant and has a 500 hour<br />

salt spray rating.<br />

Conductors<br />

The conductors are fabricated from<br />

98% conductivity copper. The bars<br />

are “spaced-in-air” and held securely<br />

in the housing by the plug-in outlets<br />

and joints.<br />

Neutral<br />

100% neutral is available for standard 4<br />

wire applications. A second neutral bar<br />

can be added for 200% neutral capacity.<br />

Note: the 200% neutral bar can be utilized<br />

as Isolated Ground.<br />

The internal ground bus is 100% rated<br />

for 100A, 60% rated for 225A, and 50%<br />

for 400A busway. Isolated ground is<br />

rated at 100% for both amperages.<br />

Plating<br />

The entire length of the bus bar is tin<br />

plated to ensure good electrical<br />

contact at all joint and plug tap-off<br />

points. The plating also serves to<br />

protect the bars from corrosion.<br />

Optional silver plating is available.<br />

Plug-in base<br />

XJ-L HD Busway features multiple plugin<br />

locatons. The plastic, non-tracking<br />

outlets are located on 20 or 9.75 inch<br />

centers and support the bus bars providing<br />

bracing during short circuit conditions.<br />

The plug-in outlets are IP2X<br />

(finger safe).<br />

Joint connection<br />

Busway sections are connected via a<br />

maintenance-free, spring pressure joint.<br />

The busway ends are easily aligned and<br />

bus bar ends are held securely in place<br />

by spring pressure clips located in<br />

the joint insulator. The housings are<br />

connected via external housing plates<br />

and captive screws.<br />

Bus plugs<br />

There are twleve plug-in outlets on<br />

each 10 foot (3.048 m) section, six<br />

openings on 5 foot (1.524 m) sections<br />

and two outlets on 2 foot (.616 m)<br />

sections. Bus plugs are available with<br />

amperages ranging from 15A to 100A.<br />

Bus plugs feature circuit breakers or<br />

fusible switch disconnects.<br />

Testing<br />

Each piece of XJ-L HD Busway is<br />

factory tested prior to shipment. A<br />

dielectric test is performed to ensure<br />

product integrity. XJ-L HD Busway<br />

is manufactured and inspected in<br />

accordance to an ISO 9001 registered<br />

Quality Management System.<br />

Standards<br />

XJ-L HD Busway products meet the<br />

following standards:<br />

UL 857<br />

NEMA BU1<br />

CSA C22.2<br />

Ratings<br />

Amperage:<br />

Voltage:<br />

Short circuit:<br />

100A, 225A and 400A<br />

600 VAC max a<br />

100A – 10kAIC<br />

225A – 22kAIC<br />

400A – 35kAIC<br />

a 225A three phase four or five wire has 277/480V max<br />

R,X,Z and voltage drop<br />

Ampere<br />

rating<br />

Bus bar width<br />

x .125 in. (3.2 mm)<br />

thick<br />

Ohm x 10- 3 per 100 ft.<br />

Line to neutral<br />

Voltage drop – concentrated loads, line-to-line per 100 ft.<br />

at 100% rated load, 35°C ambient power factor<br />

R X Z 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0<br />

100 0.50 (13.0) 1.67 8.71 1.88 2.30 2.54 2.75 2.94 3.10 3.21 3.25 2.89<br />

225 1.00 (25.4) 8.20 4.08 9.16 2.48 2.74 2.98 3.19 3.37 3.51 3.57 3.20<br />

400 2.13 (54.1) 4.27 3.01 5.23 2.88 3.10 3.29 3.44 3.56 3.62 3.57 2.96<br />

15-66<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


XJ-L HD Busway System<br />

Straight Sections<br />

Plug-in section<br />

Plug-in Busway Only<br />

Prefix Type Fitting Type Amp Configuration Color Plug-In Location Plug-In Spacing<br />

BW J P 1 2 0 1 6 G L 2<br />

XJ-L HD<br />

Plug-in<br />

Plug-in sections<br />

Length:<br />

024 = 24 inches<br />

060 = 60 inches<br />

120 = 120 inches<br />

1 = 100<br />

2 = 225<br />

4 = 400<br />

1 = 3Ø<br />

2 = 3Ø + Internal Grd<br />

3 = 3Ø + Isolated Grd<br />

4 = 3Ø + Internal Grd + Isolated Grd<br />

5 = 3Ø + Neutral<br />

6 = 3Ø + Neutral + Internal Grd<br />

7 = 3Ø + Neutral + Isolated Grd<br />

8 = 3Ø + Neutral + Internal Grd + Isolated Grd<br />

9 = 3Ø + 200% Neutral<br />

0 = 3Ø + 200% Neutral + Internal Ground<br />

A = Graphite<br />

G = ANSI 61<br />

X = Other<br />

Available in 10 foot (3.048 m), 5 foot (1.524 m) or 2 foot (.616 m) standard plug-in lengths, XJ-L HD<br />

Busway offers layout flexibility to meet custom requirements. Plug-in busway can be configured with<br />

six plug-in openings per side or twelve on one side.<br />

L = Left Side Only<br />

R = Right Side Only<br />

S = Dual Side<br />

1 = 20” Dual Side a<br />

2 = 9.75” Single<br />

Side b<br />

Notes:<br />

a Use for Plug-in Length = “S”<br />

b Use for Plug-in Length = “L” or “R”<br />

Feeder Section<br />

Prefix Type Fitting Type Amp Configuration Color<br />

BW J F 1 2 0 1 6 G<br />

XJ-L HD<br />

Feeder<br />

Length in inches,<br />

Ex. 2’ 3” = 024<br />

Feeder lengths<br />

available from<br />

16” (016) up to<br />

10’ 0” (120)<br />

1 = 100<br />

2 = 225<br />

4 = 400<br />

1 = 3Ø<br />

2 = 3Ø + Internal Grd<br />

3 = 3Ø + Isolated Grd<br />

4 = 3Ø + Internal Grd + Isolated Grd<br />

5 = 3Ø + Neutral<br />

6 = 3Ø + Neutral + Internal Grd<br />

7 = 3Ø + Neutral + Isolated Grd<br />

8 = 3Ø + Neutral + Internal Grd + Isolated Grd<br />

9 = 3Ø + 200% Neutral<br />

0 = 3Ø + 200% Neutral + Internal Ground<br />

A = Graphite<br />

G = ANSI 61<br />

X = Other<br />

15<br />

BUSWAY SYSTEMS<br />

Feeder Sections<br />

Feeder busway carries the current of the busway system from the supply source. Feeder busway does<br />

not have plug-in outlets. Feeder busway is available in custom lengths from 16.00 in (406mm) to 120.00<br />

in (3048mm). Feeder sections are available as Indoor.<br />

XJ-L HD Busway also features an exclusive rotating cover plate to facilitate inspection of the joints.<br />

The light weight design of the busway and plugs makes the installation of XJ-L HD Busway quick and<br />

trouble-free.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-67


XJ-L HD Busway System<br />

Straight Sections<br />

Plug-in Section (Dual Side)<br />

Plug-in Section (Single Side–Right hand configuration shown)<br />

9.75 in<br />

(248 mm)<br />

9.75 in<br />

(248 mm)<br />

9.75 in<br />

(248 mm)<br />

Top<br />

15<br />

BUSWAY SYSTEMS<br />

4.0 in<br />

(102 mm)<br />

Insulator<br />

End<br />

9.75 in<br />

(248 mm)<br />

10.0 ft<br />

(3.05 m)<br />

9.75 in<br />

(248 mm)<br />

7.0 in<br />

(178 mm)<br />

Inspection<br />

window<br />

Plug-in Section<br />

Ampere<br />

Rating<br />

Bus Bar<br />

Material<br />

Bar<br />

Thickness<br />

Bar<br />

Width<br />

Housing<br />

Width<br />

Housing<br />

Height<br />

Max<br />

Voltage<br />

Short<br />

Circuit<br />

Rating<br />

Length<br />

Ft (M)<br />

3 Pole 4 Pole<br />

Model Number <br />

Wgt.<br />

(lb) Model Number Wgt.<br />

(lb)<br />

100 Copper .125 (3.2) .5 (13) 2.0 (51) 6.13 (156) 600V 10kA 10.0 (3.05) BWJP12011GS1 42 BWJP12015GS1 45<br />

100 Copper .125 (3.2) .5 (13) 2.0 (51) 6.13 (156) 600V 10kA 5.0 (1.52) BWJP06011GS1 21 BWJP06015GS1 23<br />

100 Copper .125 (3.2) .5 (13) 2.0 (51) 6.13 (156) 600V 10kA 2.0 (.61) BWJP02411GS1 8 BWJP02415GS1 9<br />

225 Copper .125 (3.2) 1.0 (25) 2.5 (64) 6.13 (156) 600V 22kA 10.0 (3.05) BWJP12021GS1 56 BWJP12025GS1 62<br />

225 Copper .125 (3.2) 1.0 (25) 2.5 (64) 6.13 (156) 600V 22kA 5.0 (1.52) BWJP06021GS1 28 BWJP06025GS1 30<br />

225 Copper .125 (3.2) 1.0 (25) 2.5 (64) 6.13 (156) 600V 22kA 2.0 (.61) BWJP02421GS1 10 BWJP02425GS1 12<br />

400 Copper .125 (3.2) 2.12 (54) 3.6 (92) 6.13 (156) 600V 35kA 10.0 (3.05) BWJP12041GS1 69 BWJP12045GS1 79<br />

400 Copper .125 (3.2) 2.12 (54) 3.6 (92) 6.13 (156) 600V 35kA 5.0 (1.52) BWJP06041GS1 35 BWJP06045GS1 40<br />

400 Copper .125 (3.2) 2.12 (54) 3.6 (92) 6.13 (156) 600V 35kA 2.0 (.61) BWJP02441GS1 15 BWJP02445GS1 17<br />

Model Numbers Effective Aug 2011<br />

Feeder Section<br />

Ampere<br />

Rating<br />

Bus Bar<br />

Material<br />

Bar<br />

Thickness<br />

Bar<br />

Width<br />

Housing<br />

Width<br />

Housing<br />

Height<br />

Max<br />

Voltage<br />

Short<br />

Circuit<br />

Rating<br />

Length<br />

In. (mm)<br />

3 Pole 4 Pole<br />

10' Model<br />

Number <br />

Wgt.<br />

(lb/ft)<br />

10' Model<br />

Number <br />

100 Copper .125 (3.2) .5 (13) 2.0 (51) 6.13 (156) 600V 10kA<br />

BWJF12011GS1 4.2 BWJP12015GS1 4.5<br />

16.0-120.0<br />

225 Copper .125 (3.2) 1.0 (26) 2.5 (64) 6.13 (156) 600V 22kA BWJF12021GS1 5.6 BWJP12025GS1 6.2<br />

(406 - 3048)<br />

400 Copper .125 (3.2) 2.12 (54) 3.6 (92) 6.13 (156) 600V 35kA BWJF12041GS1 6.9 BWJP12045GS1 7.9<br />

Wgt.<br />

(lb/ft)<br />

15-68<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


XJ-L HD Busway System<br />

Elbows<br />

Fittings<br />

Prefix Type Fitting Type Amp Configuration Color<br />

BW J E L E L 1 7 A<br />

XJ-L HD E L<br />

Elbow<br />

E = Edge<br />

F = Flat<br />

L = Left<br />

R = Right<br />

1 = 100<br />

2 = 225<br />

4 = 400<br />

1 = 3Ø<br />

2 = 3Ø + Internal Grd<br />

3 = 3Ø + Isolated Grd<br />

4 = 3Ø + Internal Grd + Isolated Grd<br />

5 = 3Ø + Neutral<br />

6 = 3Ø + Neutral + Internal Grd<br />

7 = 3Ø + Neutral + Isolated Grd<br />

8 = 3Ø + Neutral + Internal Grd + Isolated Grd<br />

9 = 3Ø + 200% Neutral<br />

0 = 3Ø + 200% Neutral + Internal Ground<br />

A = Graphite<br />

G = ANSI 61<br />

X = Other<br />

Flat elbows<br />

Right hand or left hand XJ-L HD Busway system 90<br />

degree flat elbows are available. When specifying be<br />

sure to use the proper catalog number suffix to identify<br />

the required fitting.<br />

Edge elbows<br />

Right hand or left hand XJ-L HD Busway system 90<br />

degree edge elbows are available. When specifying, be<br />

sure to use the proper catalog number suffix to identify<br />

the required fitting.<br />

Flat Elbow<br />

Ampere<br />

Rating Poles Model Number Right Model Number Left<br />

100 3 BWJELFR11G BWJELFL11G<br />

100 4 BWJELFR15G BWJELFL15G<br />

225 3 BWJELFR21G BWJELFL21G<br />

225 4 BWJELFR25G BWJELFL25G<br />

400 3 BWJELFR41G BWJELFL41G<br />

400 4 BWJELFR45G BWJELFL45G<br />

Edge Elbow<br />

Ampere<br />

Rating Poles Model Number Right Model Number Left<br />

100 3 BWJELER11G BWJELEL11G<br />

100 4 BWJELER15G BWJELEL15G<br />

225 3 BWJELER21G BWJELEL21G<br />

225 4 BWJELER25G BWJELEL25G<br />

400 3 BWJELER41G BWJELEL41G<br />

400 4 BWJELER45G BWJELEL45G<br />

15<br />

BUSWAY SYSTEMS<br />

Flat right elbow shown<br />

Edge right<br />

elbow shown<br />

Insulator<br />

end<br />

IG<br />

A<br />

B<br />

C<br />

N<br />

G<br />

Insulator end<br />

IG A B C N G<br />

IG A B C N G<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-69


XJ-L HD Busway System<br />

Tees and Crosses<br />

Fittings<br />

Cross<br />

Prefix Type Fitting Type Amp Configuration Color<br />

BW J C R E 2 1 7 A<br />

XJ-L HD C R E = Edge 2 1 = 100<br />

2 = 225<br />

4 = 400<br />

Cross<br />

Crosses are fittings used to interconnect<br />

two busway runs which are located at<br />

right angle to each other.<br />

1 = 3Ø<br />

2 = 3Ø + Internal Grd<br />

3 = 3Ø + Isolated Grd<br />

4 = 3Ø + Internal Grd + Isolated Grd<br />

5 = 3Ø + Neutral<br />

6 = 3Ø + Neutral + Internal Grd<br />

7 = 3Ø + Neutral + Isolated Grd<br />

8 = 3Ø + Neutral + Internal Grd + Isolated Grd<br />

9 = 3Ø + 200% Neutral<br />

0 = 3Ø + 200% Neutral + Internal Ground<br />

A = Graphite<br />

G = ANSI 61<br />

X = Other<br />

15<br />

Cross<br />

Ampere<br />

Rating Poles Model Number<br />

100 3 BWJCRE211G<br />

100 4 BWJCRE215G<br />

225 3 BWJCRE221G<br />

225 4 BWJCRE225G<br />

400 3 BWJCRE241G<br />

400 4 BWJCRE245G<br />

22.0”<br />

(559 mm)<br />

BUSWAY SYSTEMS<br />

Fittings<br />

Tee<br />

Cross – Type 2<br />

Prefix Type Fitting Type Amp Configuration Color<br />

BW J T E E 2 1 7 A<br />

XJ-L HD T E E = Edge 2,4 1 = 100<br />

2 = 225<br />

4 = 400<br />

Tee<br />

Tees permit a second run of busway to extend<br />

at right angles to a straight busway run.<br />

Tees<br />

Ampere<br />

Rating Poles Model Number Model Number<br />

100 3 BWJTEE211G BWJTEE411G<br />

100 4 BWJTEE215G BWJTEE415G<br />

225 3 BWJTEE221G BWJTEE421G<br />

225 4 BWJTEE225G BWJTEE425G<br />

400 3 BWJTEE241G BWJTEE441G<br />

400 4 BWJTEE245G BWJTEE445G<br />

1 = 3Ø<br />

2 = 3Ø + Internal Grd<br />

3 = 3Ø + Isolated Grd<br />

4 = 3Ø + Internal Grd + Isolated Grd<br />

5 = 3Ø + Neutral<br />

6 = 3Ø + Neutral + Internal Grd<br />

7 = 3Ø + Neutral + Isolated Grd<br />

8 = 3Ø + Neutral + Internal Grd + Isolated Grd<br />

9 = 3Ø + 200% Neutral<br />

0 = 3Ø + 200% Neutral + Internal Ground<br />

4.0"<br />

(102 mm)<br />

Tee – Type 2<br />

Top<br />

18.0"<br />

(457 mm)<br />

4.0"<br />

(102 mm)<br />

22.0"<br />

(559 mm)<br />

18.0"<br />

(457 mm)<br />

A = Graphite<br />

G = ANSI 61<br />

X = Other<br />

Insulator End<br />

18.0"<br />

(457 mm)<br />

22.0"<br />

(559 mm)<br />

Insulator End<br />

4.0"<br />

(102 mm)<br />

C L<br />

C L<br />

Insulator End<br />

Top<br />

Right Hand Shown<br />

Tee – Type 4<br />

Insulator End<br />

18.0"<br />

(457 mm)<br />

4.0"<br />

(102 mm)<br />

15-70<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


XJ-L HD Busway System<br />

Tap Boxes<br />

Center Tap Boxes<br />

Tap Box Only b<br />

Prefix Type Fitting Type Amp Config. Color Tap Box Steel Lug opt. Meter Meter Surface<br />

BW J C T L N 2 4 A S A 1 N<br />

XJ-L HD C T<br />

L = Left<br />

(rear)<br />

R = Right<br />

(front)<br />

N<br />

1 = 100<br />

2 = 225<br />

4 = 400<br />

A = Graphite<br />

G = ANSI 61<br />

X = Other<br />

S = Standard<br />

X = Custom /<br />

Other<br />

N = None<br />

1 = PAC3200<br />

2 = PAC3100<br />

X = Other<br />

N = None / NA<br />

L = Left<br />

R = Right (Inspection<br />

Cover Side)<br />

X = Other<br />

Center Tap Box<br />

Notes:<br />

Use X for Tap Box Steel<br />

Not required for Flanged End. Leave fields blank<br />

1 = 3Ø<br />

2 = 3Ø + Internal Grd<br />

A = Std Mech Lug<br />

3 = 3Ø + Isolated Grd<br />

B = 1.75 Dual Hole (No Lug)<br />

4 = 3Ø + Internal Grd + Isolated Grd X = Custom / Other a<br />

5 = 3Ø + Neutral<br />

D = Extended Box with 500MCM Mechanical<br />

6 = 3Ø + Neutral + Internal Grd<br />

7 = 3Ø + Neutral + Isolated Grd<br />

8 = 3Ø + Neutral + Internal Grd + Isolated Grd<br />

9 = 3Ø + 200% Neutral<br />

0 = 3Ø + 200% Neutral + Internal Ground<br />

Center Cable Tap Box<br />

Center tap boxes are non-fusible devices utilized to feed to or<br />

take off power from the busway run. When loads served by<br />

the busway run do not require over-current protection, center<br />

tap boxes may be used. If the application requires additional<br />

wiring bending space, extended center tap boxes are available.<br />

Center tap boxes are an actual part of the busway run<br />

and require a space of 32 in. (810 mm) for installation.<br />

Figure 1<br />

Right<br />

4.0”<br />

(102 mm)<br />

3.5”<br />

(89 mm)<br />

13.0”<br />

(330 mm)<br />

3.5”<br />

(89 mm)<br />

4.0”<br />

(102 mm)<br />

12.0”<br />

(305 mm)<br />

15<br />

BUSWAY SYSTEMS<br />

Figure 2<br />

Left<br />

Right Hand Shown<br />

3.5”<br />

(89 mm)<br />

4.0”<br />

(102 mm)<br />

6.13”<br />

(156 mm)<br />

Center Tap Box<br />

Ampere<br />

Rating<br />

Poles<br />

Model Number<br />

Right Connected<br />

Fig 1<br />

Model Number<br />

Left Connected<br />

Fig 2<br />

Teminals Provided<br />

Qty/Pole and Size<br />

Cu/Al wire<br />

225 3 BWJCTRN21GSANN BWJCTLN21GSANN (1) 350MCM - #6<br />

225 4 BWJCTRN25GSANN BWJCTLN25GSANN (1) 350MCM - #6<br />

400 3 BWJCTRN41GSANN BWJCTLN41GSANN (2) 350MCM - #6<br />

400 4 BWJCTRN45GSANN BWJCTLN45GSANN (2) 350MCM - #6<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-71


XJ-L HD Busway Systems<br />

Revised on 08/31/18<br />

Tap Boxes<br />

End Tap Boxes<br />

Tap Box Only b<br />

Prefix Type Fitting Type Amp Config. Color Tap Box Steel Lug opt. Meter Meter Surface<br />

BW J E T B R 2 4 A S A 1 R<br />

XJ-L HD E T B<br />

End Tap Box<br />

R =<br />

Right<br />

Notes:<br />

Use X for Tap Box Steel<br />

Not required for Flanged End. Leave fields blank<br />

1 = 100<br />

2 = 225<br />

4 = 400<br />

A = Graphite<br />

G = ANSI 61<br />

X = Other<br />

S = Standard<br />

X = Custom /<br />

Other<br />

N = None<br />

1 = PAC3200<br />

2 = PAC3100<br />

X = Other<br />

N = None / NA<br />

L = Left<br />

R = Right (Inspection<br />

Cover Side)<br />

X = Other<br />

1 = 3Ø<br />

2 = 3Ø + Internal Grd<br />

A = Std Mech Lug<br />

3 = 3Ø + Isolated Grd<br />

B = 1.75 Dual Hole (No Lug)<br />

4 = 3Ø + Internal Grd + Isolated Grd X = Custom / Other a<br />

5 = 3Ø + Neutral<br />

D = Extended Box with 500MCM Mechanical<br />

6 = 3Ø + Neutral + Internal Grd<br />

7 = 3Ø + Neutral + Isolated Grd<br />

8 = 3Ø + Neutral + Internal Grd + Isolated Grd<br />

9 = 3Ø + 200% Neutral<br />

0 = 3Ø + 200% Neutral + Internal Ground<br />

15<br />

BUSWAY SYSTEMS<br />

End Tap Box<br />

End tap boxes are devices used to connect cable and conduit<br />

to the end of a busway run or where busway runs connect<br />

without the need for over-current protection. End tap boxes<br />

may be installed at the end or beginning of a run.<br />

Tap boxes can be configured with surge protection and current<br />

monitoring devices.<br />

End Tap Box<br />

Ampere<br />

Rating Poles Model Number<br />

Teminals Provided<br />

Qty/Pole and Size Cu/Al<br />

wire<br />

100 3 BWJETBR11GS (1) 1/0 - #14<br />

100 4 BWJETBR15GS (1) 1/0 - #14<br />

225 3 BWJETBR21GS (1) 350MCM - #6<br />

225 4 BWJETBR25GS (1) 350MCM - #6<br />

400 3 BWJETBR41GS (2) 350MCM - #6<br />

400 4 BWJETBR45GS (2) 350MCM - #6<br />

5.2"<br />

(132.1 mm)<br />

2.8"<br />

(71.1 mm)<br />

16.5"<br />

(419.1 mm)<br />

5.2"<br />

(132.1 mm)<br />

26.0"<br />

(660.4 mm)<br />

16.0"<br />

(406.4 mm)<br />

Right Hand Shown<br />

9.2"<br />

(233.7 mm)<br />

15-72<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


XJ-L HD Busway System<br />

Flanged Ends<br />

Flanged End<br />

Prefix Type Fitting Type Amp Config. Color<br />

BW J F R N N 2 4 A<br />

XJ-L HD<br />

Flanged<br />

End<br />

F<br />

E = Std.<br />

R = Nema<br />

X = Other<br />

N<br />

N<br />

1 = 100<br />

2 = 225<br />

4 = 400<br />

1 = 3Ø<br />

2 = 3Ø + Internal Grd<br />

3 = 3Ø + Isolated Grd<br />

4 = 3Ø + Internal Grd + Isolated Grd<br />

5 = 3Ø + Neutral<br />

6 = 3Ø + Neutral + Internal Grd<br />

7 = 3Ø + Neutral + Isolated Grd<br />

8 = 3Ø + Neutral + Internal Grd + Isolated Grd<br />

9 = 3Ø + 200% Neutral<br />

0 = 3Ø + 200% Neutral + Internal Ground<br />

A = Graphite<br />

G = ANSI 61<br />

X = Other<br />

Flanged end<br />

Flanged ends are used to connect busway to<br />

switchboards. Flanged ends come complete with bus<br />

bar extensions to facilitate the making of electrical<br />

connections.<br />

Flanged end<br />

Ampere<br />

Rating Poles Model Number<br />

100 3 BWJFENN11GS<br />

100 4 BWJFENN15GS<br />

225 3 BWJFENN21GS<br />

225 4 BWJFENN25GS<br />

400 3 BWJFENN41GS<br />

400 4 BWJFENN45GS<br />

15<br />

BUSWAY SYSTEMS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-73


XJ-L HD Busway Systems<br />

Accessories<br />

Busway hanger<br />

XH2 and XH3 hangers are used to support<br />

XJ-L HD Busway and can be used with<br />

customer supplied rods up to 3/8 inch in<br />

diameter. Hangers are adaptable for wall<br />

mounting or ceiling suspension arrangements,<br />

either edge or flat. Custom mounting solutions<br />

available upon request.<br />

Busway Hanger<br />

Ampere<br />

Rating<br />

Model Number<br />

Dimn A<br />

in. (mm)<br />

100 BWJH0011G 2.25 (57)<br />

225 BWJH0012G 2.75 (69)<br />

400 BWJH0014G 4 (101)<br />

Tip: Bus plug access may be restricted by hangers or drop<br />

rods. This should be considered in the system layout.<br />

Hangers<br />

Prefix Type Fitting Type Amp Color<br />

BW J H 0 0 1 1 G<br />

XJ-L HD<br />

Hanger<br />

H<br />

Notes:<br />

a MTO-E Custom Product<br />

001 = Singe Drop Rod (XH style)<br />

1 = 100<br />

002 = Side Mount for strut channel a 2 = 225<br />

003 = Saddle Mount for strut channel a 4 = 400<br />

004 = Pole Mount a<br />

005 = Dual Drop Rod Saddle a<br />

006 = Dual/Single Drop Rod Frame<br />

XXX = Other a<br />

A = Graphite<br />

G = ANSI 61<br />

X = Other<br />

15<br />

BUSWAY SYSTEMS<br />

End closer<br />

An end closer is used to terminate<br />

busway runs. To extend<br />

the run, simply remove the end<br />

closer and add new sections as<br />

needed.<br />

End Closer<br />

Prefix Type Fitting Type Amp Color<br />

BW J X E N N 1 G<br />

XJ-L HD<br />

End Closer<br />

X E N N 1 = 100<br />

2 = 225<br />

4 = 400<br />

A = Graphite<br />

G = ANSI 61<br />

X = Other<br />

End Closer<br />

Ampere<br />

Rating Model Number<br />

Dimn. A<br />

in (mm)<br />

Dimn. B<br />

in (mm)<br />

100 BWJXENN1G 2.06 (52) 0.94 (24)<br />

225 BWJXENN2G 2.31 (59) 1.44 (37)<br />

400 BWJXENN4G 3.44 (87) 2.5 (64)<br />

Tip: Utilization of the busway plug-in opening adjacent to the End<br />

Closer may be limited to XQ45 bus plugs. This applies only if the End<br />

Closer is located to the Right-hand of the bus plug.<br />

XOC outlet covers<br />

Replacement outlet covers are<br />

available for closing off the plugin<br />

outlets when desired.<br />

Outlet Cover<br />

Ampere<br />

Rating Model Number <br />

100 BWJXOCN1G<br />

225 BWJXOCN2G<br />

400 BWJXOCN4G<br />

Outlet Cover<br />

Prefix Type Fitting Type Amp Color<br />

BW J X O C N 1 G<br />

XJ-L HD<br />

Plug-in Cover<br />

X O C N 1 = 100<br />

2 = 225<br />

4 = 400<br />

A = Graphite<br />

G = ANSI 61<br />

X = Other<br />

15-74<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


XJ-L HD Busway Systems<br />

Revised on 04/30/18<br />

Bus Plugs<br />

Bus plugs for XJ-L Busway are available<br />

from 15A to 100A, with molded case<br />

circuit breakers or Vacu-Break fusible<br />

switches. All XJ-L bus plugs are fully<br />

interchangeable with all XJ-L Busway<br />

configurations.<br />

Lightweight and portable, plugs can be<br />

installed or relocated as required without<br />

de-energizing the busway. Preengineered<br />

plug-in opening locations<br />

ensure no interference for greater<br />

density and maximum flexibility. This<br />

is especially important in high tech<br />

areas requiring frequent movement<br />

of equipment.<br />

XJ-L HD Bus Plugs are available<br />

with 3 or 6 branch circuit<br />

protection in both single and<br />

3-phase configurations, ranging<br />

from 15A – 100A for maximum<br />

power density and flexibility.<br />

A wide variety of NEMA and IEC<br />

receptacles or cord connections<br />

are available for the XJ-L Bus<br />

Plugs.<br />

Selection Guide<br />

Enclosure Type Plug-in Spacing Breaker Type Application<br />

A = 3 Circuit - XQ Series 20.00 & 9.75<br />

XQ style - No receptacle<br />

B = 3 Circuit - XQR Series 20.00 & 9.75 j BQ, BQH, HBQ<br />

tacle provision. May be used for<br />

custom receptacles or when additional<br />

XQR style — with duplex recep-<br />

wiring space is required<br />

C = 3 Circuit HD XPM 20.00 & 9.75 Use for applications that require<br />

D = 3-6 Circuit HD XPM 20.00 & 9.75<br />

BL, BLH, HBL,<br />

factory installed breakers and<br />

BQD, NGB<br />

receptacles<br />

G = XLEC 20.00 & 9.75 j Cover operable handle. Uses<br />

ED2,ED4,ED6,<br />

heavy duty E-Frame Breakers<br />

HED4<br />

H = XEC 20.00 & 9.75 j Uses heavy duty E-Frame breakers<br />

J = Plug-in Tap Box 20.00 na Plug-in tap off device - lugs only<br />

K = XLVB Fusible 20.00 & 9.75 j na Cover operable Vacu-Break Switch<br />

15<br />

BUSWAY SYSTEMS<br />

Siemens XJ-L HD Bus Plugs and Power Modules<br />

Prefix Type Enclosure System Config. Color Breaker Group Ampere Rating or<br />

Breaker/Receptacle<br />

Arrangement efgh<br />

Use For Breaker Group = A, B, X i<br />

Custom<br />

Features<br />

BP J H 6 A A E D 4 6 0 N N<br />

Bus<br />

Plug<br />

XJ-L HD<br />

A = 3 Circuit<br />

XQ Series<br />

B = 3 Circuit –<br />

XQ Series<br />

Receptacle<br />

Provision<br />

C = 3 Circuit HD XPM<br />

D = 3-6 Circuit HD XPM<br />

G = XLEC bfj<br />

H = XEC cfj<br />

J = Plug-in Tap<br />

Box bdh<br />

K = XLVB<br />

Fusible bdgj<br />

A = Graphite<br />

G = ANSI 61<br />

X = Other<br />

1 = 3Ø<br />

2 = 3Ø + Internal Grd<br />

3 = 3Ø + Isolated Grd<br />

4 = 3Ø + Internal Grd + Isolated Grd<br />

5 = 3Ø + Neutral<br />

6 = 3Ø + Neutral + Internal Grd<br />

7 = 3Ø + Neutral + Isolated Grd<br />

8 = 3Ø + Neutral + Internal Grd + Isolated Grd<br />

9 = 3Ø + 200% Neutral<br />

0 = 3Ø + 200% Neutral + Internal Ground<br />

A = Non-Mixed Factory<br />

Installed Breakers a<br />

E = Enclosure Only<br />

(no Breaker) ai<br />

X = Other / Fusible d<br />

See Notes below<br />

for information<br />

NN = None / NA<br />

Notes:<br />

a Use “A” or “E” for XLEC and XEC<br />

b Available in System Configs: 1,2,5,6<br />

c Available in System Configs: 1,2,3,4,5,6,7,8,9<br />

d For non-breaker style plug use “X” for Breaker Grouping field. (Fusible & Plug-in Tap Box)<br />

e For Enclosure = C,E,F see Breaker / Receptacle Arrangement Schedule for Details<br />

f For XEC and XLEC Ampere Rating field use ED2xx, ED4xx,ED6xx where xx = 15 to 00 trip rating (100A max).<br />

g For XLVB Ampere Rating field use 02xxx for 240V & 06xxx for 600V where xxx = 030, 060, 100 ampere<br />

h For Plug-in Tap Box Ampere Rating field use PBxxx where xxx = 100, 200 ampere<br />

i Ampere Rating and Customer Features fields not required for Breaker Group = “E”. Leave fields blank.<br />

j Requires two plug-in openings for 9.75 spacing.<br />

200A Tap Box installs on 20.0 dual side plug-in spacing only. Requires two plug-in openings.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-75


XJ-L HD Busway Systems<br />

Revised on 04/30/18<br />

Bus Plugs<br />

XQ and XQR Series<br />

XQ and XQR bus plugs accept BQ (bolt-on) circuit breakers.<br />

The plugs feature knockouts to facilitate quick installation.<br />

The XQR has added wiring space to allow receptacle installation.<br />

XQ Series Bus plug (60A max)<br />

Breaker Type Volts<br />

No. of<br />

Spaces<br />

Model<br />

Number<br />

Model<br />

Number<br />

BQ, BQH and HBQ 120/240 3 BPJA1GE BPJA5GE<br />

Enclosure Only<br />

15<br />

BUSWAY SYSTEMS<br />

XQR Series Bus plug (60A max)<br />

No. of Model Model<br />

Breaker Type Volts Spaces Number Number<br />

BQ, BQH and HBQ 120/240 3 BPJB1GE BPJB5GE<br />

Enclosure Only<br />

Accessories for XQ and XQR Series<br />

XEQH<br />

W62890<br />

W68101<br />

Floor Operating Handle (not for 1 pole or 2 pole breakers)<br />

Bonded Ground Kit<br />

Isolated Ground Kit<br />

XEQH<br />

W62890<br />

W68101<br />

15-76<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


XJ-L HD Busway Systems<br />

Revised on 08/30/17<br />

Bus Plugs<br />

XPM Series<br />

Use for applications that require factory installed breakers and receptacles.<br />

XPM Series HD Bus plug 3/6<br />

Interrupt<br />

Breaker<br />

Type<br />

Rating<br />

(RMS kA) Config.<br />

BL 10 1-pole 120V<br />

10 1-pole 120V<br />

22 1-pole 120V<br />

22 3-pole 240V<br />

BLH 10 2-pole 120/240V<br />

10 3-pole 120/240V<br />

22 2-pole 120/240V<br />

22 3-pole 120/240V<br />

10 1-pole 120V<br />

22 1-pole 120V<br />

65 1-pole 120V<br />

22 3-pole 240V<br />

65 3-pole 240V<br />

HBL 10 2-pole 120/240V<br />

10 3-pole 120/240V<br />

22 2-pole 120/240V<br />

22 3-pole 120/240V<br />

65 2-pole 120/240V<br />

65 3-pole 120/240V<br />

10 1-pole 120V<br />

22 1-pole 120V<br />

65 1-pole 120V<br />

10 2-pole 240V<br />

10 3-pole 240V<br />

22 2-pole 240V<br />

22 3-pole 240V<br />

65 2-pole 240V<br />

BQD<br />

65 3-pole 240V<br />

10 2-pole 120/240V<br />

10 3-pole 120/240V<br />

22 2-pole 120/240V<br />

22 3-pole 120/240V<br />

65 2-pole 120/240V<br />

65 3-pole 120/240V<br />

14 1-pole 227V<br />

14 2-pole 227/480V<br />

14 3-pole 227/480V<br />

10 1-pole 120V<br />

22 1-pole 120V<br />

65 1-pole 120V<br />

10 2-pole 240V<br />

10 3-pole 240V<br />

22 2-pole 240V<br />

22 3-pole 240V<br />

65 2-pole 240V<br />

65 3-pole 240V<br />

10 2-pole 120/240V<br />

10 3-pole 120/240V<br />

NGB<br />

22 2-pole 120/240V<br />

22 3-pole 120/240V<br />

65 2-pole 120/240V<br />

65 3-pole 120/240V<br />

14 1-pole 227V<br />

25 1-pole 227V<br />

14 2-pole 227/480V<br />

14 3-pole 227/480V<br />

25 2-pole 227/480V<br />

25 3-pole 227/480V<br />

14 1-pole 347V<br />

14 2-pole 347/600V<br />

14 3-pole 347/600V<br />

No. of<br />

Spaces<br />

Model<br />

Number<br />

6 BPJE…<br />

XPM Series HD Bus plug 3 Circuit<br />

Breaker<br />

Type<br />

BQ<br />

BQH<br />

HBQ<br />

Interrupt<br />

Rating<br />

(RMS kA) Config.<br />

10 1-pole 120V<br />

10 2-pole 240 V<br />

10 3-pole 240 V<br />

10 2-pole 120/240 V<br />

10 3-pole 120/240 V<br />

10 1-pole 120V<br />

22 1-pole 120V<br />

22 3-pole 240 V<br />

10 2-pole 120/240 V<br />

10 3-pole 120/240 V<br />

22 2-pole 120/240 V<br />

22 3-pole 120/240 V<br />

10 1-pole 120V<br />

22 1-pole 120V<br />

65 1-pole 120V<br />

22 3-pole 240 V<br />

65 3-pole 240 V<br />

10 2-pole 120/240 V<br />

10 3-pole 120/240 V<br />

22 2-pole 120/240 V<br />

22 3-pole 120/240 V<br />

65 2-pole 120/240 V<br />

65 3-pole 120/240 V<br />

3 Circuit XPM - STANDARD<br />

1.88 C L Plug-In Outlet<br />

8.35<br />

4.00<br />

6.70<br />

4.00<br />

3 Circuit XPM - EXTENDED<br />

1.88 C L Plug-In Outlet<br />

9.35<br />

No. of<br />

Spaces<br />

5.75<br />

6.63<br />

Model<br />

Number<br />

3 BPJC…<br />

6 Circuit XPM<br />

15<br />

BUSWAY SYSTEMS<br />

3-6 Circuit XPM<br />

3 Circuit XPM<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-77


XJ-L HD Busway Systems<br />

Bus Plugs<br />

XEC Series<br />

(Cover operable, 100A max)<br />

XEC bus plugs accept ED2, ED4, ED6 and HED6 circuit breakers. The plugs feature<br />

a spacious chassis which allows room for wire bending and knockout provisions.<br />

Isolated ground plugs are available from the factory.<br />

XEC Series bus plug<br />

Breaker<br />

Type<br />

Volts<br />

Ampere<br />

Rating Model Number Model Number<br />

ED2 240 100 BPJH1GAED200NN BPJH5GAED200NN<br />

ED4 480 30 BPJH1GAED430NN BPJH5GAED430NN<br />

ED6 600 60 BPJH1GAED660NN BPJH5GAED660NN<br />

Enclosure<br />

Only<br />

600 Max 15-100 BPJH1GE BPJH5GE<br />

W62890<br />

bonded<br />

ground kit<br />

15<br />

BUSWAY SYSTEMS<br />

XLEC Series<br />

(Floor operable, 100A max)<br />

XLEC bus plugs accept ED2, ED4, ED6 and HED4 circuit breakers. The plugs feature<br />

a spacious chassis which allows room for wire bending and knockout provisions.<br />

These plugs may be operated from the floor with a pull chain or hookstick.<br />

XLEC Series bus plug<br />

Breaker<br />

Type<br />

Volts<br />

Ampere<br />

Rating Model Number Model Number<br />

ED2 240 100 BPJG1GAED200NN BPJG5GAED200NN<br />

ED4 480 30 BPJG1GAED430NN BPJG5GAED430NN<br />

ED6 600 60 BPJG1GAED660NN BPJG5GAED660NN<br />

Enclosure<br />

Only<br />

600 Max 15-100 BPJG1GE BPJG5GE<br />

Additional add-on features,<br />

such as shunt trips, alarm<br />

switches, and auxillary contacts<br />

are also available for<br />

XEC and XLEC bus plugs.<br />

15-78<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


XJ-L HD Busway Systems<br />

Revised on 04/30/18<br />

Bus Plugs<br />

XLVB Series<br />

(Floor operable, 100A max)<br />

XLVB fusible bus plugs utilize the Vacu-Break switching principle, which<br />

minimizes arcing and reduces maintenance costs. The Vacu-Break bus plugs<br />

are quick-make and quick-break, cover interlocked, horsepower rated, and may<br />

be operated from the floor with a pull chain or hookstick.<br />

XLVB Series bus plug<br />

Volts<br />

Ampere<br />

Rating Model Number Model Number<br />

240 30 BPJK1GX02030NN BPJK5GX02030NN<br />

240 60 BPJK1GX02060NN BPJK5GX02060NN<br />

240 100 BPJK1GX02100NN BPJK5GX02100NN<br />

600 30 BPJK1GX06030NN BPJK5GX06030NN<br />

600 60 BPJK1GX06060NN BPJK5GX06060NN<br />

600 100 BPJK1GX06100NN BPJK5GX06100NN<br />

W47185<br />

ON/OFF labels<br />

100A Plug-in Tap Box<br />

Plug-in cable tap boxes are non-fusible<br />

devices used for end or center feed.<br />

The 100A tap boxes can be attached at<br />

any plug-in opening.<br />

15<br />

BUSWAY SYSTEMS<br />

100A Plug-in Tap Box<br />

Ampere<br />

Rating Poles Model Number<br />

100 3 BWJJ1GXPB100NN<br />

100 4 BWJJ5GXPB100NN<br />

Note: Add suffix letter “G” to catalog number for ground bus.<br />

200A Plug-in Tap Box<br />

Plug-in cable tap boxes are non-fusible devices<br />

used for end or center feed. The 200A tap box<br />

requires two adjacent openings on 20" centers.<br />

200A plug-in tap boxes are not suitable for use<br />

with XJ-L HD Busway.<br />

200A Plug-in Tap Box<br />

Ampere<br />

Rating Poles Model Number<br />

200 3 BWJJ1GXPB200NN<br />

200 4 BWJJ5GXPB200NN<br />

Note: Add suffix letter “G” to catalog number for ground bus.<br />

W62892<br />

Grd Finger Kit<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-79


Busway Power Distribution<br />

BD Plug-In (225 — 1600 Ampere) Copper<br />

Revised on 08/30/17<br />

Selection<br />

Ampere<br />

Rating<br />

Plug In<br />

10’–0”<br />

Straight<br />

Length<br />

Catalog<br />

Number<br />

Case<br />

Dimensions<br />

(inches)<br />

Shipping<br />

Weight<br />

Lb./Ft.<br />

90° Elbow<br />

Prefix <br />

Catalog<br />

Number<br />

Switch-Board<br />

Connection <br />

Prefix<br />

Building<br />

Expansion<br />

Fitting<br />

Catalog<br />

Number<br />

Cable Tap Box<br />

End <br />

Catalog<br />

Number<br />

Center <br />

Catalog<br />

Number<br />

End Closure<br />

Catalog<br />

Number<br />

3-Phase, 3-Wire<br />

225 BDP302 4 1 ⁄16 x 8 7 ⁄8 09 LDP302 FEP302 EJP302 ETB302 CTB302 ECP6<br />

400 BDP304 4 1 ⁄16 x 8 7 ⁄8 12 1 ⁄2 LDP304 FEP304 EJP304 ETB304 CTB304 ECP6<br />

600 BDP306 4 1 ⁄16 x 8 7 ⁄8 13 1 ⁄2 LDP306 FEP306 EJP306 ETB306 CTB306 ECP6<br />

800 BDP308 6 1 ⁄16 x 8 7 ⁄8 18 1 ⁄2 LDP308 FEP308 EJP308 ETB308 CTB308 ECP10<br />

1000 BDP310 6 1 ⁄16 x 8 7 ⁄8 22 LDP310 FEP310 EJP310 ETB310 CTB310 ECP10<br />

1350 BDP313 12 1 ⁄8 x 8 7 ⁄8 28 LDP313 FEP313 EJP313 ETB313 CTB313 ECA10<br />

1600 BDP316 12 1 ⁄8 x 8 7 ⁄8 29 LDP316 FEP316 EJP316 ETB316 CTB316 ECA10<br />

3-Phase, 4-Wire — Full Capacity Neutral<br />

225 BDP4024 4 1 ⁄16 x 8 7 ⁄8 12 LDP4024 FEP4024 EJP4024 ETB4024 CTB4024 ECP6<br />

400 BDP4044 4 1 ⁄16 x 8 7 ⁄8 14 1 ⁄2 LDP4044 FEP4044 EJP4044 ETB4044 CTB4044 ECP6<br />

600 BDP4064 4 1 ⁄16 x 8 7 ⁄8 15 1 ⁄2 LDP4064 FEP4064 EJP4064 ETB4064 CTB4064 ECP6<br />

800 BDP4084 8 1 ⁄8 x 8 7 ⁄8 28 LDP4084 FEP4084 EJP4084 ETB4084 CTB4084 ECA8<br />

1000 BDP4104 8 1 ⁄8 x 8 7 ⁄8 32 LDP4104 FEP4104 EJP4104 ETB4101 CTB4101 ECA8<br />

Rod-Hanger Adapter (optional) UJ100<br />

Hangers <br />

Catalog<br />

Number<br />

600V or Less<br />

BDH10<br />

BDH12<br />

480V or Less<br />

BDH10<br />

BDH12<br />

15<br />

BUSWAY SYSTEMS<br />

Aluminum to Copper Cross Reference<br />

Aluminum BD Busway is no longer available. Please use the cross reference<br />

below to identify compatible copper equivalent.<br />

Plug In<br />

10'– 0"<br />

Straight<br />

Length Case<br />

Ampere Catalog Dimensions<br />

Rating Number (inches)<br />

Aluminum<br />

3-Phase, 3-Wire<br />

225 ABD302 4 1 ⁄16 x 8 7 ⁄8<br />

400 ABD304 4 1 ⁄16 x 8 7 ⁄8<br />

600 ABD306 6 1 ⁄16 x 8 7 ⁄8<br />

Plug In<br />

10'– 0"<br />

Straight<br />

Length Case<br />

Ampere Catalog Dimensions<br />

Rating Number (inches)<br />

Copper<br />

3-Phase, 3-Wire<br />

225 BDP302 4 1 ⁄16 x 8 7 ⁄8<br />

400 BDP304 4 1 ⁄16 x 8 7 ⁄8<br />

600 BDP306 4 1 ⁄16 x 8 7 ⁄8<br />

“M” Rating / Standard Rating<br />

Conversion Table<br />

1000/A Square Inch Standard<br />

“M” Rating<br />

Rating Equivalent<br />

225 —<br />

400 0600<br />

600 0800<br />

800 0800<br />

1000 1000<br />

1200 —<br />

1350 1350<br />

1600 1600<br />

2000 —<br />

2500 —<br />

3000 —<br />

4000 —<br />

800 ABD308 6 1 ⁄16 x 8 7 ⁄8<br />

1000 ABD310 12 1 ⁄8 x 8 7 ⁄8<br />

1200 ABD312 12 1 ⁄8 x 8 7 ⁄8<br />

3-Phase, 4-Wire — Full Capacity Neutral<br />

225 ABD4024 4 1 ⁄16 x 8 7 ⁄8<br />

400 ABD4044 4 1 ⁄16 x 8 7 ⁄8<br />

600 ABD4064 6 1 ⁄16 x 8 7 ⁄8<br />

800 ABD4084 8 1 ⁄8 x 8 7 ⁄8<br />

1000 ABD4104 12 1 ⁄8 x 8 7 ⁄8<br />

1200 ABD4124 12 1 ⁄8 x 8 7 ⁄8<br />

For inches / millimeters conversion, see Application Data<br />

Section.<br />

For higher short circuit ratings add an “H” after the “D”<br />

or “P” (ABDH302 or BDPH302). Consult sales office for<br />

ratings.<br />

“GK” suffix is an internal ground bus. For any other<br />

ground configuration, consult local sales office. Please<br />

use following footage for fittings:<br />

Elbow - 3'<br />

SWB - 1'<br />

End Cable Tap Box - 1'<br />

Center Cable Tap Box - 10'<br />

Building Expansion - 10'<br />

800 BDP308 6 1 ⁄16 x 8 7 ⁄8<br />

1000 BDP310 6 1 ⁄16 x 8 7 ⁄8<br />

1350 BDP313 12 1 ⁄8 x 8 7 ⁄8<br />

1600 BDP316 12 1 ⁄8 x 8 7 ⁄8<br />

3-Phase, 4-Wire — Full Capacity Neutral<br />

225 BDP4024 4 1 ⁄16 x 8 7 ⁄8<br />

400 BDP4044 4 1 ⁄16 x 8 7 ⁄8<br />

600 BDP4064 4 1 ⁄16 x 8 7 ⁄8<br />

800 BDP4084 8 1 ⁄8 x 8 7 ⁄8<br />

1000 BDP4104 8 1 ⁄8 x 8 7 ⁄8<br />

<br />

Right Edgewise<br />

Elbow (-2)<br />

Left Edgewise<br />

Elbow (-4)<br />

<br />

Suffix Description<br />

-1 Right Flatwise Appropriate suffix<br />

-2 Right Edgewise must be added to<br />

-3 Left Flatwise Elbow Catalog<br />

-4 Left Edgewise Number to order.<br />

Switchboard stub includes flange to cover cutout<br />

in top of indoor switchboard and 6" of bus inside<br />

switchboard. Connecting hardware supplied by<br />

switchboard manufacturer.<br />

Includes busway stub. Total length added to run is 2’<br />

for 225A and 400A aluminum or 225A–600A copper; 3’ for<br />

all others. Box is designed to connect to offset bus-bar<br />

ends. When it is to be connected to straight bus-bar ends,<br />

adapter will be furnished upon request.<br />

Must be factory-assembled to busway. Complete<br />

device includes 10’ busway.<br />

Two hangers included free of charge with each busway<br />

section, elbow, tee and cross.<br />

15-80<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: BUSW


Busway Power Distribution<br />

XL-U Aluminum (225–5000 Ampere)<br />

Selection<br />

225–5000 Amperes / 600 Volts or Less<br />

Non-Ventilated 225–600 Amperes<br />

Busway Catalog Number<br />

Ampere<br />

Rating<br />

3-Pole<br />

Basic<br />

Catalog<br />

Number<br />

Case<br />

Dimensions<br />

(inches)<br />

Shipping<br />

Weight<br />

Lb./Ft.<br />

Wall Flange<br />

Catalog<br />

Number<br />

Floor<br />

Support<br />

Catalog<br />

Number<br />

End Closure<br />

Catalog<br />

Number<br />

Hangers <br />

Catalog<br />

Number<br />

225 UH302AB 4 1 ⁄2 x 10 8 UF145 UFS145 UE145 UH145<br />

400 UH304AB 4 1 ⁄2 x 10 9 UF145 UFS145 UE145 UH145<br />

600 UH306AB 5 1 ⁄2 x 10 10 UF145 UFS145 UE155 UH155<br />

4-Pole Full Neutral<br />

225 UH502AB 4 1 ⁄2 x 10 8 UF145 UFS145 UE145 UH145<br />

400 UH504AB 4 1 ⁄2 x 10 9 UF145 UFS145 UE145 UH145<br />

600 UH506AB 5 1 ⁄2 x 10 10 UF145 UFS145 UE155 UH155<br />

Ventilated 800–5000 Amperes With Ground Bus<br />

Busway Sections Complete<br />

Ampere Rating<br />

Edge-wise Flat-wise Basic<br />

Catalog<br />

Number<br />

3-Pole<br />

Case<br />

Dimensions<br />

(inches)<br />

Shipping<br />

Weight<br />

Lb./Ft.<br />

Wall<br />

Flange<br />

Catalog<br />

Number<br />

Floor<br />

Support<br />

Catalog<br />

Number<br />

End<br />

Closure<br />

Catalog<br />

Number<br />

Hangers <br />

Catalog<br />

Number<br />

800 800 UH308AV 4 1 ⁄2 x 10 10 UF145 UFS145 UE145 UH145<br />

1000 800 UH310AV 4 1 ⁄2 x 10 11 UF145 UFS145 UE145 UH145<br />

1200 1000 UH312AV 5 1 ⁄2 x 10 12 UF155 UFS145 UE155 UH155<br />

1350 1200 UH313AV 5 1 ⁄2 x 10 13 UF155 UFS145 UE155 UH155<br />

1600 1350 UH316AV 7 1 ⁄2 x 10 16 UF175 UFS179 UE175 UH175<br />

2000 1600 UH320AV 7 1 ⁄2 x 10 19 UF175 UFS179 UE175 UH175<br />

2500 2000 UH325AV 9 1 ⁄2 x 10 23 UF195 UFS179 UE175 UH195<br />

3000 3000 UH330AV 7 1 ⁄2 x 20 5 ⁄8 32 UF275 UFS279 UE275 UH275<br />

4000 3500 UH340AV 9 1 ⁄2 x 20 5 ⁄8 41 UF295 UFS279 UE295 UH295<br />

5000 4000 UH350AV 9 1 ⁄2 x 20 5 ⁄8 45 UF295 UFS279 UE295 UH295<br />

4-Pole Full Neutral<br />

800 800 UH508AV 4 1 ⁄2 x 10 11 UF145 UFS145 UE145 UH145<br />

1000 800 UH510AV 4 1 ⁄2 x 10 12 UF145 UFS145 UE145 UH145<br />

1200 1000 UH512AV 5 1 ⁄2 x 10 14 UF155 UFS145 UE155 UH155<br />

1350 1200 UH513AV 5 1 ⁄2 x 10 15 UF155 UFS145 UE155 UH155<br />

1600 1350 UH516AV 7 1 ⁄2 x 10 18 UF175 UFS179 UE175 UH175<br />

2000 1600 UH520AV 7 1 ⁄2 x 10 21 UF175 UFS179 UE175 UH175<br />

2500 2000 UH525AV 9 1 ⁄2 x 10 26 UF195 UFS179 UE195 UH195<br />

3000 3000 UH530AV 7 1 ⁄2 x 20 5 ⁄8 35 UF275 UFS279 UE275 UH275<br />

4000 3500 UH540AV 9 1 ⁄2 x 20 5 ⁄8 47 UF295 UFS279 UE295 UH295<br />

5000 4000 UH550AV 9 1 ⁄2 x 20 5 ⁄8 52 UF295 UFS279 UE295 UH295<br />

XLU Suffix Table<br />

Description<br />

Suffix<br />

Feeder<br />

F<br />

Plug-in<br />

P<br />

Elbow<br />

L<br />

Tee<br />

T<br />

Cross<br />

X<br />

Switchboard Connection S<br />

Expansion Section J<br />

Center Tap Box<br />

M<br />

End Tap Box<br />

B<br />

XFMR Throat —<br />

XFMR Tap 1-3 Phase —<br />

XFMR Tap 3-1 Phase —<br />

Roof Flange —<br />

Fused Reducer —<br />

Non Fused Reducer —<br />

15<br />

BUSWAY SYSTEMS<br />

Ventilated XL-U busway has two ratings; see above for<br />

edgewise or flatwise mounting.<br />

For rod-hanger adapter UJ100 see page 15-80.<br />

GENERAL NOTES:<br />

1) For inches / millimeters conversion, see Application<br />

Data Section.<br />

2) To form complete catalog number, use basic catalog<br />

number and substitute suffix of required item. Example:<br />

Basic busway Catalog Number U316AV— accessory<br />

switchboard stub with ground bus U316AVSG.<br />

3) Totally Enclosed offering is available up to 3000A Al.<br />

Replace “V” with “E” in catalog number.<br />

4) The following feeder busway footages apply:<br />

XL-U Elbow 2’ XLU-EXP Section 4’<br />

XL-U Tee 3’ XL-U SWBD Stub 1’<br />

XL-U Cross 4’ XL-U Reducer 4’<br />

5) For higher short circuit rating add an “HH” after the<br />

“U” (UHH302ABP)<br />

6) Floor and ceiling flanges are ordered by description.<br />

7) Internal ground bar provided as standard.<br />

8) For elbows other than 90°, accessory charge is doubled.<br />

9) Switchboard stub includes flange to cover cutout<br />

in top of indoor switchboard and 8” of bus inside<br />

switchboard. Connecting hardware supplied by<br />

switchboard manufacturer.<br />

10)Transformer throat connection includes gasketed box<br />

sized to match throat plus flexible straps and bolts.<br />

No Busway footage is included. For connection to<br />

transformers not manufactured by Siemens, consult<br />

factory<br />

Product Category: BUSW<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-81


Busway Power Distribution<br />

XL-U Copper (225–6500 Amperes)<br />

Selection<br />

225–6500 Amperes / 600 Volts or Less<br />

Non-Ventilated 225–600 Amperes<br />

15<br />

BUSWAY SYSTEMS<br />

Busway Catalog Number<br />

Ampere<br />

Rating<br />

3-Pole<br />

Basic<br />

Catalog<br />

Number<br />

Case<br />

Dimensions<br />

(inches)<br />

Shipping<br />

Weight<br />

Lb./Ft.<br />

Wall<br />

Flange<br />

Catalog<br />

Number<br />

Floor<br />

Support<br />

Catalog<br />

Number<br />

End<br />

Closure<br />

Catalog<br />

Number<br />

Hangers <br />

Catalog<br />

Number<br />

225 UH302CB<br />

8 UF145 UFS145 UE145 UH145<br />

400 UH304CB 4 1 ⁄2 x 10 12 UF145 UFS145 UE145 UH145<br />

600 UH306CB 13 UF145 UFS145 UE145 UH145<br />

4-Pole Full Neutral<br />

225 UH502CB<br />

9 UF145 UFS145 UE145 UH145<br />

400 UH504CB 4 1 ⁄2 x 10 13 UF145 UFS145 UE145 UH145<br />

600 UH506CB 15 UF145 UFS145 UE145 UH145<br />

Ventilated 800–5000 Amperes With Ground Bus<br />

Busway Sections Complete<br />

Ampere Rating <br />

Edge-wise Flat-wise Basic<br />

Catalog<br />

Number<br />

3-Pole<br />

Case<br />

Dimensions<br />

(inches)<br />

Shipping<br />

Weight<br />

Lb./Ft.<br />

Wall<br />

Flange<br />

Catalog<br />

Number<br />

Floor<br />

Support<br />

Catalog<br />

Number<br />

End<br />

Closure<br />

Catalog<br />

Number<br />

Hangers <br />

Catalog<br />

Number<br />

800 UH308CV 4 1 ⁄2 x 10 12 UF145 UFS145 UE145 UH145<br />

1000 1000 UH310CV 4 1 ⁄2 x 10 15 UF145 UFS145 UE145 UH145<br />

1200 1000 UH312CV 4 1 ⁄2 x 10 16 UF145 UFS145 UE145 UH145<br />

1350 1200 UH313CV 4 1 ⁄2 x 10 19 UF145 UFS145 UE145 UH145<br />

1600 1350 UH316CV 5 1 ⁄2 x 10 23 UF155 UFS145 UE155 UH155<br />

2000 1600 UH320CV 5 1 ⁄2 x 10 26 UF155 UFS145 UE155 UH155<br />

2500 2000 UH325CV 7 1 ⁄2 x 10 34 UF175 UFS179 UE175 UH175<br />

3000 2500 UH330CV 9 1 ⁄2 x 10 41 UF195 UFS179 UE195 UH195<br />

4000 4000 UH340CV 7 1 ⁄2 x 20 5 ⁄8 57 UF275 UFS279 UE275 UH275<br />

5000 4500 UH350CV 7 1 ⁄2 x 20 5 ⁄8 70 UF275 UFS275 UE275 UH275<br />

6000 5000 UH360CV 9 1 ⁄2 x 20 5 ⁄8 85 UF295 UFS279 UE295 UH295<br />

6500 5500 UH365CV 9 1 ⁄2 x 20 5 ⁄8 98 UF295 UFS279 UE295 UH295<br />

4-Pole Full Neutral<br />

800 800 UH508CV 4 1 ⁄2 x 10 14 UF145 UFS145 UE145 UH145<br />

1000 1000 UH510CV 4 1 ⁄2 x 10 18 UF145 UFS145 UE145 UH145<br />

1200 1000 UH512CV 4 1 ⁄2 x 10 19 UF145 UFS145 UE145 UH145<br />

1350 1200 UH513CV 4 1 ⁄2 x 10 23 UF145 UFS145 UE145 UH145<br />

1600 1350 UH516CV 5 1 ⁄2 x 10 28 UF155 UFS145 UE155 UH155<br />

2000 1600 UH520CV 5 1 ⁄2 x 10 30 UF155 UFS145 UE155 UH155<br />

2500 2000 UH525CV 7 1 ⁄2 x 10 42 UF175 UFS179 UE175 UH175<br />

3000 2500 UH530CV 7 1 ⁄2 x 10 61 UF195 UFS179 UE195 UH195<br />

4000 4000 UH540CV 7 1 ⁄2 x 20 5 ⁄8 70 UF275 UFS279 UE275 UH275<br />

5000 4500 UH550CV 7 1 ⁄2 x 20 5 ⁄8 86 UF275 UFS279 UE275 UH275<br />

6000 5000 UH560CV 9 1 ⁄2 x 20 5 ⁄8 105 UF295 UFS279 UE295 UH295<br />

6500 5500 UH565CV 9 1 ⁄2 x 20 5 ⁄8 122 UF295 UFS279 UE295 UH295<br />

XLU Suffix Table<br />

Description<br />

Suffix<br />

Feeder<br />

F<br />

Plug-in<br />

P<br />

Elbow<br />

L<br />

Tee<br />

T<br />

Cross<br />

X<br />

Switchboard Connection S<br />

Expansion Section J<br />

Center Tap Box<br />

M<br />

End Tap Box<br />

B<br />

XFMR Throat —<br />

XFMR Tap 1-3 Phase —<br />

XFMR Tap 3-1 Phase —<br />

Roof Flange —<br />

Fused Reducer —<br />

Non Fused Reducer —<br />

“M” Rating / Standard Rating<br />

Conversion Table<br />

1000/A Square Inch<br />

“M” Rating<br />

225<br />

400<br />

600<br />

800<br />

1000<br />

1200<br />

1350<br />

1600<br />

2000<br />

2500<br />

3000<br />

4000<br />

Standard<br />

Rating Equivalent<br />

—<br />

—<br />

800<br />

1200<br />

1350<br />

1600<br />

2000<br />

2500<br />

2500<br />

3000<br />

4000<br />

5000<br />

Ventilated XL-U busway has two ratings; see above for<br />

edgewise or flatwise mounting.<br />

For rod-hanger adapter UJ100 see page 15-80.<br />

GENERAL NOTES:<br />

1) For inches / millimeters conversion, see Application<br />

Data Section.<br />

2) To form complete catalog number, use basic catalog<br />

number and substitute suffix of required item. Example:<br />

Basic busway Catalog Number U316CV— accessory<br />

switchboard stub with ground bus U316CVSG.<br />

3) Totally Enclosed offering is available up to 4000A Cu.<br />

Replace “V” with “E” in catalog number.<br />

4) The following feeder busway footages apply:<br />

XL-U Elbow 2’ XLU-EXP Section 4’<br />

XL-U Tee 3’ XL-U SWBD Stub 1’<br />

XL-U Cross 4’ XL-U Reducer 4’<br />

5) For higher short circuit rating add an “HH” after the “U”<br />

(UHH302CBP)<br />

6) Floor and ceiling flanges are ordered by description.<br />

7) Internal ground bar provided as standard.<br />

8) For elbows other than 90°, accessory charge is doubled.<br />

9) Switchboard stub includes flange to cover cutout in top<br />

of indoor switchboard and 8” of bus inside switchboard.<br />

Connecting hardware supplied by switchboard<br />

manufacturer.<br />

10)Transformer throat connection includes gasketed box<br />

sized to match throat plus flexible straps and bolts.<br />

No Busway footage is included. For connection to<br />

transformers not manufactured by Siemens, consult<br />

factory<br />

15-82<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: BUSW


Busway Power Distribution<br />

Revised on 08/30/17<br />

XL-X, XL-U, BD Plug-In Units<br />

Circuit Breaker Plugs<br />

As of June 2014, Siemens no long supplies a complete solution for Legacy bus plug offerings.<br />

Floor Operable<br />

Breaker<br />

Type<br />

AC<br />

Volts<br />

ED2 240<br />

ED4 480<br />

Ampere<br />

Rating<br />

15–60<br />

70–100<br />

15–60<br />

70–100<br />

15–60<br />

70–100<br />

3-Phase, 3-Wire<br />

Enclosure Only b<br />

Catalog Number b<br />

XL-X<br />

Catalog Number b<br />

XL-U<br />

Catalog Number<br />

BD Plug-In ab<br />

3-Phase, 4-Wire<br />

Enclosure Only b<br />

Catalog Number b<br />

XL-X<br />

Catalog Number b<br />

XL-U<br />

Catalog Number<br />

BD Plug-In ab<br />

REC3100G UEC3100G BEC3100 REC4100G UEC4100G BEC4100<br />

ED6<br />

600<br />

FD6, FXD 70–250 RFC3250G UFC3250G BFC3250 RFC4250G UFC4250G BFC4250<br />

Selection<br />

I-T-E Fusible Vacu-Break ® Switch Plugs Floor-Operable with Line Terminal Protection<br />

3-Phase, 3-Wire<br />

3-Phase, 4-Wire<br />

Horsepower Ratings Catalog Number Horsepower Ratings, AC Catalog Number<br />

Volts<br />

250 AC<br />

or<br />

250 DC<br />

600 AC<br />

Ampere<br />

Rating<br />

Standard<br />

(NEC)<br />

Maximum<br />

(Time Delay) XL-X XL-U<br />

BD <br />

Plug-In a<br />

Standard<br />

(NEC)<br />

Note: These are for use on busway with internal ground<br />

bus manufactured after March, 1986. For ground kits<br />

prior to this date, consult local sales office.<br />

Maximum<br />

(Time Delay) XL-X XL-U<br />

BD <br />

Plug-In a<br />

030 003 007½ RV321G UV321G BOS14321 003 007½ RV421G UV421G BOS16421<br />

060 007½ 015 RV322G UV322G BOS14322 007½ 015 RV422G UV422G BOS16422<br />

100 015 030 RV323G UV323G BOS14323 015 030 RV423G UV423G BOS16423<br />

200 025 060 RV324G UV324G BOS14324 025 060 RV424G UV424G BOS16424<br />

030 007½ 020 RV361G UV361G BOS14351 005 015 RV461G UV461G BOS16451<br />

060 015 050 RV362G UV362G BOS14352 015 030 RV462G UV462G BOS16452<br />

100 030 075 RV363G UV363G BOS14353 025 060 RV463G UV463G BOS16453<br />

200 060 150 RV364G UV364G BOS14354 050 125 RV464G UV464G BOS16454<br />

Fuse Adapter Kits — RV and UV<br />

Class “J”<br />

Catalog<br />

Number<br />

Class “T”<br />

Catalog<br />

Number<br />

Class “R”<br />

Catalog<br />

Number<br />

240V AC/250V DC<br />

30<br />

<br />

W56626<br />

60<br />

<br />

W56628<br />

100<br />

<br />

TFAK32 W55365<br />

200<br />

<br />

TFAK42 W55366<br />

600V<br />

30<br />

<br />

W56627<br />

60<br />

<br />

W56629<br />

100<br />

<br />

TFAK35 W55365<br />

200<br />

<br />

TFAK45 W55366<br />

Field Addable Ground Kits for<br />

BD Bus Plugs Fusible<br />

Ampere Rating Catalog Number<br />

30–60 W63231<br />

100 W63232<br />

200 W63233<br />

Fuse Adapter Kits — BOS<br />

Amperage<br />

Amperage<br />

Class “J”<br />

Catalog<br />

Number<br />

Class “T”<br />

Catalog<br />

Number<br />

Class “R”<br />

Catalog<br />

Number<br />

240V AC/250V DC<br />

30<br />

<br />

W56626<br />

60<br />

<br />

W56628<br />

100 W49827 TFAK32 W55365<br />

200 W49819 TFAK42 W55366<br />

600V<br />

30 W49832<br />

<br />

W56627<br />

60 W49830<br />

<br />

W56629<br />

100 W49828 TFAK35 W55365<br />

200 W49818 TFAK45 W55366<br />

15<br />

BUSWAY SYSTEMS<br />

a Grounding Finger — See table.<br />

b Enclosures available from stock. When ordering<br />

circuit breaker bus plugs complete with breaker,<br />

factory-installed, allow time for assembly and SPECIFY<br />

enclosure frame size, phase and ampere rating.<br />

Example: One UEC3100—ED4—3P—70A–factory<br />

assembled<br />

c When BD busway capacity exceeds 400A for aluminum<br />

or 600A for copper, capacity must be specified to obtain<br />

proper number and arrangement of neutral fingers.<br />

Not required.<br />

Replace “_” with “1” or “2” .<br />

See Table: BD Bus Plug Catalog Number Ref. shown on<br />

Page 15-61.<br />

Product Category: BPLU<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-83


Busway Power Distribution<br />

XL-X, XL-U and BD Plug-In Units and Cubicles<br />

Shipping Weights — Pounds<br />

For Circuit Breaker Bus Plugs Only<br />

3-Phase, 3-Wire<br />

Breaker<br />

Type<br />

Ampere<br />

Rating<br />

Enclosure<br />

Only<br />

XL-U<br />

XL-X<br />

BD,<br />

LO-X<br />

Complete<br />

Assembly<br />

XL-U<br />

XL-X<br />

BD,<br />

LO-X<br />

3-Phase, 4-Wire<br />

Enclosure<br />

Only<br />

XL-U<br />

XL-X<br />

BD,<br />

LO-X<br />

Complete<br />

Assembly<br />

XL-U<br />

XL-X<br />

ED2,<br />

ED4, 15–100 12 14 13 15 13 15 14 10<br />

ED6<br />

FD6,<br />

FXD<br />

70–250 1 27 51 37 45 28 55 38<br />

Fusible and Molded Case Circuit Breaker Cubicles<br />

See page 15-33 for typical configurations.<br />

BD,<br />

LO-X<br />

Shipping Weights — Pounds<br />

For Fusible Switch Bus Plugs Only<br />

3-Phase, 3-Wire<br />

XL-X<br />

XL-U BD, LO-X<br />

Switch<br />

Ampere<br />

Rating<br />

Prefix<br />

RV<br />

UV<br />

Prefix<br />

BOS<br />

Revised on 06/30/18<br />

Selection<br />

3-Phase, 4-Wire<br />

XL-X<br />

XL-U BD, LO-X<br />

Prefix<br />

RV<br />

UV<br />

Prefix<br />

BOS<br />

30,60 17 15 19 12<br />

100 17 18 19 18<br />

200 36 34 38 36<br />

BD Bus Plug Catalog Number Reference<br />

Catalog<br />

Number<br />

ABD4 Busway<br />

225<br />

ABD402<br />

400<br />

ABD404<br />

600<br />

ABD406<br />

800<br />

ABD408<br />

1000<br />

ABD410<br />

1200<br />

ABD412<br />

BDP4 Busway<br />

225<br />

BDP402<br />

400<br />

BDP404<br />

600<br />

BDP406<br />

800<br />

BDP408<br />

1000<br />

BDP410<br />

1350<br />

BDP413<br />

BOS16451 — — u — u u — — — — — u u<br />

BOS16452 — u — u — — — u u u u — —<br />

As of June 2014, Siemens no long supplies a complete solution for Legacy bus plug offerings.<br />

1600<br />

BDP416<br />

BUSWAY SYSTEMS<br />

15<br />

15-84<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: BPLU


Motor Control Centers<br />

SPEEDFAX TM<br />

Section<br />

tiastar Motor Control Center<br />

c o n t e n t s<br />

Product Overview<br />

Overview of tiastarTM 16-2<br />

Construction Details 16-3 – 16-4<br />

Technical<br />

Dimensions and Weights 16-5<br />

Wiring Classifications 16-6<br />

Incoming Cable Space, Wiring Troughs, Wiring Terminations 16-7<br />

Components Overview<br />

Heavy Duty Starters 16-8<br />

Overload Relays 16-9<br />

SIRIUS Soft Starters 16-10<br />

Variable Frequency Drives 16-11<br />

Modular Converter 16-12 –16-14<br />

Power Monitoring 16-15<br />

Surge Protective Devices 16-16<br />

Selection Guide<br />

Starter Ratings and Dimensions 16-17 – 16-18<br />

Power Distribution Ratings and Dimensions 16-21<br />

Aftermarket<br />

Product History 16-22 – 16-23<br />

MCC Quote Request Form 16-24<br />

16<br />

MOTOR CONTROL<br />

CENTERS<br />

Solid State Starter Class 14<br />

ESP200 Solid State Overload<br />

Scan to connect<br />

online to the<br />

most up-todate<br />

version of<br />

this Section of<br />

SPEEDFAX.<br />

(Section was last modified on 07/17/18)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 16-1


tiastar Motor Control Centers<br />

Overview of tiastar<br />

Product Overview<br />

16<br />

MOTOR CONTROL<br />

CENTERS<br />

Motor Control Centers at Siemens<br />

Motor control centers (MCC) have<br />

come a long way since they were introduced<br />

in 1937 as a way to save floor<br />

space by placing several starters in a<br />

single cabinet. Modern processes and<br />

facilities now dictate that motor control<br />

centers should display a high level of<br />

intelligence as well. They must deliver<br />

vital operating information; plus provide<br />

automation features, optimal control,<br />

and critically fast communications to<br />

meet even the most demanding applications.<br />

Ideally, the best-of the-best<br />

must also save installation time and<br />

money. Siemens MCCs are designed<br />

as self-contained modular units. They<br />

come with rear-mounted, self-aligning<br />

copper stabs that firmly grasp onto the<br />

bus. Brackets also guide the placement<br />

of units, further assuring positive<br />

engagement with the bus.<br />

tiastar MCC<br />

Siemens tiastar MCC is based on the<br />

Furnas System/89 TM MCC introduced<br />

in 1980 and represent the state-of-theart<br />

motor control technology, with a<br />

modular, open architecture design. High<br />

performance and quality expectations<br />

have been researched at the planning<br />

stage and throughout the construction<br />

stage. The Siemens tiastar MCC has<br />

many features and options to meet your<br />

specific needs. Requirements such as<br />

the standard isolated vertical bus to fully<br />

insulated and isolated vertical bus and<br />

standard 22mm to 30mm pilot devices.<br />

Heavy gauge steel is used for framing<br />

and side panel; sections are separated<br />

by 14 gauge steel barriers that are<br />

formed to provide rigidity and durability.<br />

The modular units implement all the<br />

motor protection and control functions,<br />

determine operational, diagnostic and<br />

statistical data, and organize communications<br />

data between the automation system<br />

and the motor feeder.<br />

tiastar SMART MCC<br />

Siemens tiastar Smart MCC with<br />

PROFIBUS-DP Communications combines<br />

heavy-duty construction and user<br />

friendly features. These intelligent units<br />

deliver detailed diagnostics by communicating<br />

with starter units, variable<br />

frequency drives, reduced voltage softstart<br />

units, circuit breakers, or power<br />

meters via PLC/DCS. This means overload<br />

relays, linked to the PLCs, can now<br />

deliver detailed motor management<br />

data at speeds previously unheard of.<br />

PROFIBUS-DP, the backbone of the<br />

system, greatly simplifies I/O wiring.<br />

Also, custom communication options<br />

such as PROFINET and Modbus RTU<br />

are available.<br />

Domestic Design Standards<br />

The following are the principal domestic<br />

standards which apply to motor control<br />

center design, testing, construction and<br />

application. The tiastar motor control<br />

center complies fully with the latest<br />

version of all these standards.<br />

NEMA<br />

n AB-1 Molded Case Circuit Breakers<br />

n ICS 1 General Standards for Industrial<br />

Control<br />

n ICS 2.3 Industrial Control Systems:<br />

Instructions for the Handling,<br />

Installation, Operation, and<br />

Maintenance of Motor Control Centers<br />

n ICS 18 Standard for motor control centers<br />

NFPA – National Fire Protection<br />

Association<br />

n 70 National Electrical Code<br />

Low Voltage Seismic<br />

Compliance<br />

Today, strict seismic requirements are<br />

not limited to areas prone to earthquakes.<br />

Engineers in all locations must<br />

be aware of, and comply with, earthquake<br />

protection regulations. In addition<br />

to construction materials and techniques,<br />

these regulations cover nonstructural<br />

building systems, including<br />

electrical components. In critical applications,<br />

such as healthcare facilities,<br />

these components must be designed<br />

to go beyond surviving an earthquake,<br />

to remain in operation after the event<br />

is over.<br />

At Siemens, we are committed to making<br />

it easier for you to comply with all<br />

building requirements, including seismic<br />

ratings.<br />

Please contact your Siemens representative<br />

for complete details on seismic<br />

rating compliance for specific products<br />

and configurations.<br />

The purpose of this compliance assessment<br />

is to document the seismic compliance<br />

of tiastar motor control center to<br />

the following building codes:<br />

Building code<br />

Edition<br />

Uniform Building Code (UBC) 1997<br />

BOCA National Building Code 1999<br />

(BOCA)<br />

Standard Building Code (SBC) 1999<br />

California Building Code (CBC) 2013<br />

International Building Code (IBC) 2012<br />

Earthquake loading compliance tests (shake<br />

tests) were performed at Clarke Dynamic<br />

Test Laboratories in accordance with ICC-ES-<br />

AC 156 and ASCE 7-10.<br />

tiastar Motor Control Center<br />

UL<br />

n 845 Motor Control Centers<br />

n 508 Industrial Control Equipment<br />

n 891 Switchboard Design<br />

n 94 Test for Flammability of Plastic<br />

Materials for Parts, Devices, and<br />

Appliances<br />

n 489 Molded Case Circuit Breakers and<br />

Circuit Breaker Enclosures<br />

n 991 Tests for Safety-related Controls<br />

Employing Solid-state Devices<br />

Notes:<br />

1. tiastar motor control centers are certified to the stringent<br />

seismic requirements of California OSHPD (Office<br />

of Statewide Health Planning and Development).<br />

Approval # OSP-0074-10. For details, refer to: http://<br />

www.oshpd.ca.gov/FDD/Pre-Approval/.<br />

2. The codes and standards referenced in this document<br />

are published by independent organizations, institutes,<br />

or agencies. All copyrights and trademarks related to<br />

such codes and publications and the use thereof belong<br />

to the entities owning rights to the same.<br />

3. These test results indicate third-party analysis of the<br />

Siemens product for compliance to the referenced<br />

codes and editions. Nothing in this publication should<br />

be taken as endorsements, official approvals, or official<br />

test results provided by the publishers of the referenced<br />

codes or any code enforcement authorities.<br />

16-2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


tiastar Motor Control Centers<br />

Construction Details<br />

Quality Features Exceed Standards<br />

Siemens tiastar motor control centers<br />

are composed of a number of vertical<br />

sections bolted together. That allows<br />

for future addition of MCC vertical units<br />

so the equipment can expand with<br />

customer needs. The standards structure<br />

is 90 in. (2286 mm) high, plus a 1.125 in.<br />

(29 mm) high channel sill. Front-only<br />

structures can be either 15 in. (381 mm)<br />

or 20 in. (508 mm) deep. Double deep<br />

mounted structures are 30 in. (762 mm)<br />

or 40 in. (1016 mm) deep, and consist of<br />

two horizontal and vertical buses. This<br />

Product Overview<br />

allows for correct bus phasing on the<br />

front or rear. Siemens provides a 21 in.<br />

back-to-back design, consisting of a<br />

common horizontal and vertical bus<br />

structure, for applications where<br />

available footprint is limited.<br />

<br />

2<br />

4<br />

3<br />

16<br />

5<br />

MOTOR CONTROL<br />

CENTERS<br />

6<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 16-3


tiastar Motor Control Centers<br />

Construction Details<br />

Product Overview<br />

Features<br />

Entire horizontal<br />

bus assembly<br />

is in top 12”<br />

of the vertical<br />

section<br />

4 Isolated and<br />

insulated vertical<br />

bus assembly<br />

(Optional)<br />

2 Clear Lexan®<br />

horizontal<br />

wireway barrier<br />

5 Dual location pilot<br />

device panel<br />

16<br />

MOTOR CONTROL<br />

CENTERS<br />

3 Plug-in units<br />

with integrated<br />

racking handles<br />

6 Industry’s best<br />

unit operating<br />

handle<br />

Important Additional Features:<br />

J All wiring and components meet or exceed the<br />

requirements of UL, CSA, NEMA, EEMAC, and NEC<br />

J Pre-wired components are professionally harnessed<br />

to industrial terminal blocks<br />

J Full depth wire tie rods are standard in each vertical<br />

wireway<br />

J<br />

J<br />

J<br />

J<br />

White interior increases visibility for easy wiring,<br />

maintenance and inspection<br />

Modular units are fully interchangeable<br />

Each tiastar MCC is designed to satisfy your most<br />

exacting specifications<br />

White on black base operating handle is easy to<br />

identify<br />

16-4<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


tiastar Motor Control Centers<br />

Dimensions and Weights<br />

Technical<br />

Dimensions<br />

Structure<br />

Height 91.125 in. (2315 mm)<br />

Front Mounted Only Structure (FO)<br />

Width 20 in. (508 mm)<br />

24 in. (610 mm)<br />

30 in. (762 mm)<br />

40 in. (1016 mm)<br />

50 in. (1270 mm)<br />

60 in. (1524 mm)<br />

Depth 15 in. (381 mm)<br />

20 in. (508 mm)<br />

Back to Back Structure (BTB)<br />

Width 20 in. (508 mm)<br />

30 in. (762 mm)<br />

Depth 21 in. (533 mm)<br />

Double Deep MCC<br />

Depth 31 in. (787 mm)<br />

41 in. (1441 mm)<br />

Vertical Wireway<br />

Height 72 in. (1829 mm)<br />

Width 4 in. (102 mm)<br />

Optional width 8 in. (203.2 mm)<br />

Depth 10 in. (254 mm)<br />

Cross Section 38.25 sq. in. (972 sq. mm)<br />

With Opt width 76.50 sq. in. (1943 sq. mm)<br />

Top Horizontal Wireway<br />

Height 12 in. (305 mm)<br />

Depth 7 in. (178 mm)<br />

Bottom Horizontal Wireway<br />

Height 6 in. (152 mm)<br />

Depth 15 in. (381 mm)<br />

20 in. (508 mm)<br />

30 in.* (762 mm)*<br />

* BTB 40 in.* (1016 mm)*<br />

Enclosure Types<br />

NEMA 1<br />

Indoor<br />

NEMA 1A Gasketed Indoor<br />

NEMA 2 Drip proof Indoor<br />

NEMA 12 Dust tight Indoor<br />

NEMA 3R Rainproof<br />

Outdoor<br />

(Non walk-in)<br />

Pull Box (Top Hat)<br />

Height 12 in.<br />

18 in.<br />

24 in.<br />

Width<br />

20 in.<br />

30 in.<br />

Depth<br />

15 in.<br />

20 in.<br />

Structural Gauge Chart<br />

Structural Parts<br />

Divider Sheets<br />

Side Sheets<br />

Center Bottom Cross Ties<br />

Rear Channel (FO)<br />

Channel Sills<br />

Center-Top Channel<br />

Vertical Bus Mounting Angles<br />

Lifting Angles<br />

Rear Covers<br />

Top Plates<br />

End Covers<br />

Separator Angles<br />

Shelf Brackets<br />

Unit Parts<br />

Top and Bottom Unit Barriers<br />

Back Pan<br />

14 ga.<br />

14 ga.<br />

12 ga.<br />

13 ga.<br />

7 ga.<br />

13 ga.<br />

14 ga.<br />

7 ga.<br />

16 ga.<br />

13 ga.<br />

16 ga.<br />

12 ga.<br />

10 ga.<br />

14 ga.<br />

13 ga.<br />

14 ga.<br />

Side Barrier Plate<br />

18 ga.<br />

Angles<br />

14 ga.<br />

Doors<br />

13 ga.<br />

14 ga.<br />

Finish (Ext.)<br />

ANSI 61 Light Gray<br />

Electrostatically applied TGIC-free polyester<br />

powder in standard.<br />

Bus<br />

Horizontal Bus (A) 600A Cu<br />

800A<br />

Cu<br />

1200A<br />

Cu<br />

1600A<br />

Cu<br />

2000A<br />

Cu<br />

2500A* Cu *NEMA 1 only<br />

600A<br />

Al<br />

800A<br />

Al<br />

1200 Al<br />

Vertical Bus (A) 300A Cu<br />

600A<br />

Cu<br />

800A<br />

Cu<br />

Neutral Bus (Bottom Mounted) (A) 600A Cu<br />

800A<br />

Cu<br />

1200A<br />

Cu<br />

1600A<br />

Cu<br />

Options<br />

Full Neutral Cu<br />

Neutral Landing Pad<br />

Bus Bracing (KA Sym)<br />

42KA<br />

65KA<br />

100KA*<br />

* Cu Only<br />

Barriers<br />

Isolation Barrier<br />

Grounded sheet steel with stab openings<br />

Glass filled polyester sandwich that isolates<br />

Insulated & Isolated Barrier and insulates each phase from the others and<br />

the bus from the front and rear compartments<br />

Removable covers<br />

Inserts to cover unused openings in V-bus<br />

barrier<br />

Option available for the stab in location of<br />

Automatic shutter mechanism each plug-in unit and requested future space.<br />

Standard in Arc Resistant MCCs.<br />

Ground Bus<br />

Horizontal (Bottom Mounted) (A) 300A Cu<br />

Required for UL labeling 600A Cu<br />

600A<br />

Al<br />

Vertical (A)* 300A Cu<br />

* Available with motor ground terminations<br />

Plating<br />

All power bus, tin plated is Standard<br />

Silver plating available by request (Cu only)<br />

Incoming Line Terminations<br />

Incoming line arrangements are available in many<br />

configurations from 600A to 2500A<br />

Weight Table<br />

Dimensions Inches (mm)<br />

H W D Type<br />

Shipping weight for<br />

NEMA 1, 2, and 12<br />

91.125 (2315) 20 (508) 15 (381) FO 550 (250) 650 (295)<br />

20 (508) 20 (508) FO 650 (295) 700 (318)<br />

30 (762) 15 (381) FO 700 (318) 800 (363)<br />

30 (762) 20 (508) FO 850 (386) 900 (409)<br />

20 (508) 21 (533) BTB 670 (304) N/A<br />

30 (762) 21 (533) BTB 880 (400) N/A<br />

Wiring Specifications<br />

Control on Units<br />

Interconnection<br />

control wiring<br />

between Units<br />

Power wiring–<br />

Sized to suit<br />

maximum HP<br />

rating of unit<br />

16 ga. copper<br />

105°C<br />

600V<br />

14 ga. copper<br />

105°C<br />

600V<br />

14 ga. to 2 ga. copper 105°C<br />

600V<br />

1 ga. to 500 kcmil copper 105°C<br />

600V<br />

Weights per Section in<br />

lbs (Kg) for NEMA 3R<br />

16<br />

MOTOR CONTROL<br />

CENTERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 16-5


tiastar Motor Control Centers<br />

Wiring Classifications<br />

Technical<br />

16<br />

MOTOR CONTROL<br />

CENTERS<br />

Siemens MCC’s are available as either<br />

Class I or Class II assemblies utilizing<br />

either<br />

Type A, Type B, or Type C wiring as defined<br />

in NEMA ICS18-2001. Below are the<br />

NEMA class and type definitions:<br />

Class I — Independent Units<br />

Class I motor control centers shall consist<br />

of mechanical groupings of combination<br />

motor control units, feeder tap units, other<br />

units, and electrical devices arranged in a<br />

convenient assembly. The manufacturer<br />

shall furnish drawings that include:<br />

a. Overall dimensions of the motor control<br />

center, identification of units and their<br />

location in the motor control center,<br />

locations of incoming line terminals,<br />

mounting dimensions, available conduit<br />

entrance areas, and the location of the<br />

master terminal board if required (Type C<br />

wiring only).<br />

b. Manufacturer’s standard diagrams for<br />

individual units and master terminal boards<br />

(Type C wiring only) consist of one or more<br />

drawing(s) that:<br />

1. Identify electrical devices.<br />

2. Indicate electrical connections.<br />

3. Indicate terminal numbering<br />

designations.<br />

Note: When a combination schematic and /<br />

or wiring diagram for a unit is supplied<br />

showing optional devices, the manufacturer<br />

shall provide information to indicate which<br />

devices are actually furnished.<br />

Class II — Interconnected Units<br />

Class II motor control centers shall be the<br />

same as Class I motor control centers with<br />

the addition of manufacturer furnished<br />

electrical interlocking and wiring between<br />

units as specified in overall control system<br />

diagrams supplied by the purchaser.<br />

In addition to the drawings furnished<br />

for Class I motor control centers, the<br />

manufacturer shall furnish drawings that<br />

indicate factory interconnections within the<br />

motor control center.<br />

Class I-S and II-S — Motor Control<br />

Centers With Custom Drawing<br />

Requirements<br />

Class I-S and II-S motor control centers<br />

shall be the same as Class I and II except<br />

custom drawings shall be provided in lieu<br />

of standard drawings as specified by the<br />

user. Examples of custom drawings are:<br />

b Special identifications for electrical<br />

devices<br />

b Special terminal numbering designations<br />

b Special sizes of drawings<br />

The drawings supplied by the manufacturer<br />

shall convey the same information<br />

as drawings provided with Class I and II<br />

motor control centers, additionally modified<br />

as specified by the user.<br />

Types of Wiring<br />

Type A<br />

User field wiring shall connect directly to<br />

device terminals internal to the unit and<br />

shall be provided only on Class I motor<br />

control centers.<br />

Type B<br />

a. Type B user field load wiring for<br />

combination motor control units size 3 or<br />

smaller shall be designated as B-D or B-T,<br />

according to the following:<br />

b B-D connects directly to the device<br />

terminals, which are located immediately<br />

adjacent and readily accessible to the<br />

vertical wireway.<br />

b B-T connects directly to a load terminal<br />

block in, or adjacent to, the unit.<br />

b. Type B user field load wiring for<br />

combination motor control units larger than<br />

size 3, and for feeder tap units, shall<br />

connect directly to unit device terminals.<br />

c. Type B user field control wiring<br />

shall connect directly to unit terminal<br />

block(s) located in, or adjacent to, each<br />

combination motor control unit.<br />

Type C<br />

User field control wiring shall connect<br />

directly to master terminal blocks mounted<br />

at the top or bottom of those vertical<br />

sections that contain combination motor<br />

control units or control assemblies which<br />

shall be factory wired to their master<br />

terminal blocks. User field load wiring for<br />

combination motor control units, size 3 or<br />

smaller, shall connect directly to master<br />

terminal blocks mounted at the top or<br />

bottom of vertical sections. Motor control<br />

unit load wiring shall be factory wired to<br />

the<br />

master terminal blocks. User field load<br />

wiring for combination motor control units<br />

larger than size 3, and for feeder tap units,<br />

shall connect directly to unit device<br />

terminals.<br />

Type A<br />

Figure 1. Class I, Type A Wiring<br />

Type B<br />

Figure 2. Class I, Type B-d Wiring<br />

Figure 3. Class I, Type B-t Wiring<br />

Type C<br />

Figure 4. Class I, Type C Wiring<br />

16-6<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


tiastar Motor Control Centers<br />

Incoming Cable Space, Wiring Troughs, Wiring Terminations<br />

Technical<br />

The National Electrical Code establishes<br />

very specific guidelines for minimum<br />

cable bending space within motor control<br />

centers. Figures 1 through 5 below<br />

describe the most common<br />

arrangements for terminating main<br />

incoming power cables in the MCC.<br />

Consult Siemens for incoming line<br />

compartment braced for 100,000<br />

amperes symmetrical, short circuit.<br />

Incoming Cable Space<br />

Description of<br />

Incoming Service<br />

≤ 350 kcmil<br />

Two per Phase<br />

≤ 600 kcmil One or<br />

Two per Phase<br />

≤ 600 kcmil Three or<br />

Four per Phase<br />

750 kcmil One or<br />

Two per Phase<br />

350 kcmil One or<br />

Two per Phase<br />

≤ 600 kcmil One or<br />

Two per Phase<br />

≤ 750 kcmil, up to eight per phase<br />

≤ 500 kcmil One or Two per Phase<br />

≤ 750 kcmil One per Phase to<br />

Main Breaker<br />

≤ 500 kcmil One to<br />

Four per Phase<br />

≤ 750 kcmil One per Phase to<br />

Main Breaker<br />

Busway or Cable Feed<br />

to Line Reactor<br />

Top or Bottom<br />

Incoming Section<br />

Top — Directly<br />

on Main Bus<br />

Top<br />

Top<br />

Top<br />

Bottom<br />

Bottom<br />

Top or Bottom<br />

Top<br />

Top<br />

Top or Bottom<br />

Cable Entry<br />

Top or Bottom<br />

Either<br />

Either<br />

Top<br />

Top<br />

Bottom<br />

Bottom<br />

Either<br />

Bottom<br />

Top<br />

Either<br />

Space Requirements<br />

in Inches (mm)<br />

Top Wireway plus<br />

12.0 (305) or<br />

18.0 (457)<br />

Top Wireway plus<br />

24.0 (607)<br />

Bottom Wireway plus<br />

18.0 (457)<br />

Bottom Wireway plus<br />

24.0 (610)<br />

See<br />

Breaker / Disconnect<br />

See<br />

Breaker / Disconnect<br />

Consult Siemens<br />

Notes<br />

None See Figure 3<br />

Top Wireway plus<br />

18.0 (457)<br />

Full Structure<br />

See Figure 1<br />

See Figure 1<br />

—<br />

600 A Maximum<br />

See Figure 2<br />

600 A Maximum<br />

See Figure 2<br />

Consult Siemens<br />

See Figure 4<br />

See Figure 5<br />

Consult Siemens<br />

Siemens MCC’s are equipped with a 12 in. (305 mm) high, full-width horizontal wireway in the top and 6 in. (152 mm) in the bottom<br />

of each structure. A separate vertical wireway connects the top and bottom wiring areas in each vertical section. This wireway is 4<br />

in. (102 mm) wide by 10 in. (254 mm) deep.<br />

Note: All standard Siemens termination schemes shown herein do comply with applicable cable bending requirements of UL and the NEC.<br />

Figure 1<br />

Figure 2<br />

Figure 3<br />

16<br />

Main Lugs at Top with Top Cable Entry<br />

Can accommodate up to two 600 kcmil cables<br />

per phase when using Siemens standard<br />

mechanical lugs. A total height of 24 in. (610<br />

mm). This includes 12 in. (305 mm) for the top<br />

wireway plus 12 in. (305mm) of unit space.<br />

Compression lugs require extra vertical space<br />

or the addition of a top hat.<br />

Main Lugs at Bottom with Bottom Cable<br />

Entry<br />

Lugs are bolted directly to the bottom of the<br />

vertical bus. Can accommodate up to two 350<br />

kcmil per phase in 24 in. (610 mm) high<br />

compartment. This includes 6 in. (152 mm) for<br />

the bottom wireway plus 18 in. (457 mm) of unit<br />

space. Can accommodate up to two 600 kcmil<br />

per phase in 30 in. (762 mm) high compartment.<br />

This includes 6 in. (152 mm) for the bottom<br />

wireway plus 24 in. (610 mm) of unit space.<br />

Main Lugs at Top with Top or Bottom<br />

Cable Entry<br />

In this arrangement the lugs mount directly<br />

on the horizontal bus, eliminating the need to<br />

use unit mounting space. The limitation here<br />

is 350 kcmil cable per phase.<br />

MOTOR CONTROL<br />

CENTERS<br />

Figure 4<br />

Figure 5<br />

Main Disconnect with Bottom Cable Entry<br />

Main Disconnect with Top Cable Entry<br />

If bottom entry is used, cables must be properly laced and supported based upon the available short circuit<br />

current. See dimensional requirements for molded case breakers and fused switches, consult local sales office.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 16-7


tiastar Motor Control Centers<br />

Heavy Duty Starters<br />

Components Overview<br />

16<br />

MOTOR CONTROL<br />

CENTERS<br />

Heavy Duty Starters<br />

Size 00–4 magnetic starters include the<br />

following standard features:<br />

b Rugged Industrial Design<br />

b Half Sizes for Cost and Space Savings<br />

b Dual Voltage, Dual Frequency Coils<br />

b Solid State or Ambient Compensated<br />

Bimetal Overload Protection<br />

b Wide Range of Accessories<br />

b Easy Coil Access<br />

b Overload Test Feature<br />

b Straight Thru Wiring<br />

b Gravity Dropout<br />

b Large Silver Cadmium Contacts<br />

b UL listed file #E14900 (class 14, 22,<br />

30, 40 & 43)<br />

b CSA certified file #LR 6535 (class 14,<br />

22, 30, 40 & 43)<br />

Application<br />

Heavy Duty starters are designed for<br />

across the line starting of single phase<br />

and polyphase motors.<br />

These controls are available in NEMA<br />

Sizes 00 through 8. In addition to the<br />

usual NEMA Starter Sizes, Siemens<br />

offers three exclusive Half Sizes; 1 3 ⁄4,<br />

2 1 ⁄2 and 3 1 ⁄2. These integral sizes offer<br />

the same rugged, industrial<br />

construction as our NEMA Sizes and<br />

ensure efficient operating performance.<br />

Half Sizes provide a real cost savings<br />

by cutting down on over capacity when<br />

NEMA Sizes exceed the motor ratings.<br />

All Siemens Heavy Duty controls,<br />

including our popular Half Sizes comply<br />

with applicable NEMA and UL tests.<br />

All starters are supplied with a NO<br />

holding interlock that in conjunction<br />

with an appropriate pilot device will<br />

provide low voltage protection or<br />

release.<br />

NEMA starters are ideal for<br />

applications requiring dependability<br />

and durability. Typical applications<br />

include use with machine tools, air<br />

conditioning equipment, material<br />

handling equipment, compressors,<br />

hoists and various production and<br />

industrial equipment as well as in<br />

demanding automotive applications.<br />

Solid State Starter Class 14<br />

16-8<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


tiastar Motor Control Centers<br />

Overload Relays<br />

Components Overview<br />

Overload Protection<br />

Siemens understands customer needs<br />

vary from motor to motor. That is why<br />

we offer 4 lines of overload protection.<br />

For basic needs you can specify bi-metal<br />

ambient compensated overloads. If<br />

single phase is a concern our customers<br />

can specify ESP200, and for the most<br />

advanced motor protection, customers<br />

can consider SIMOCODE overloads that<br />

provide detailed information and control.<br />

Ambient Compensated Bimetal<br />

Single Phase and Three Phase<br />

Ambient Compensated Bimetal<br />

Overloads<br />

These thermal type overload relays are<br />

used to protect motors from excessive<br />

heat resulting from sustained motor<br />

overloads, rapid motor cycling and stalled<br />

rotor conditions. Although these devices<br />

function based on thermal principles<br />

they are designed to compensate for<br />

the ambient air temperature surrounding<br />

the overload. This helps prevent the<br />

occurrence of nuisance tripping when<br />

there are high surrounding ambient temperatures.<br />

The percentage of overload<br />

determines the length of time required<br />

to open the circuit.<br />

b Ambient Compensated Bimetal<br />

Overloads<br />

—Automatic or manual reset adjustment<br />

—A manual test button is provided<br />

to test the operation of the 3-pole<br />

overload relay control contacts<br />

—w15% nominal trip current adjustment<br />

—Accept either standard Class 20 or<br />

Quick Trip (NEMA Class 10) heater<br />

elements without any other changes<br />

or adjustments<br />

—Available with a normally open contact<br />

for an alarm circuit (SPDT) up to<br />

60A<br />

—Compensated bimetal overload<br />

relays provide a constant trip time in<br />

ambient temperatures from –20°F to<br />

r170°F for a given heater rating<br />

b UL Listed File #E22655 or Component<br />

Recognized<br />

b CSA Certified File #LR6535<br />

ESP200 Solid State Overload<br />

ESP200 Solid State Overloads<br />

Designed for a wide variety of applications.<br />

The field selectable Trip Class 5,<br />

10, 20 or 30 can easily be set by 2 DIP<br />

switches. This eliminates the guess<br />

factor of an application requirements<br />

and provides reduced inventory for<br />

multiple applications. The inherent<br />

benefits of the ESP200 ultimately<br />

results in cost savings for the user.<br />

ESP200 has a 4:1 current adjustment<br />

range with a fine adjustment dial<br />

labeled in full load amps. The heaterless<br />

overload minimizes the heat<br />

trapped in the enclosures, reduces<br />

cost for ventilation or cooling. Easily<br />

accessible Reset button, provides visible<br />

and audible indications to ensure<br />

the tripped overload is ready to restart.<br />

Designed to replace thermal, or<br />

ESP100 overload relays for any application.<br />

It has the same dimensions<br />

and footprint of the ESP100 overload<br />

relays. It can be directly coupled to the<br />

contactors or remotely mounted. In<br />

addition to the NEMA contactor applications,<br />

it also can be used with other<br />

types of controllers for applications<br />

requiring DP or IEC contactors. As a<br />

retrofit for other brands, it is used with<br />

a plate available for retrofitting competitive<br />

products.<br />

SIMOCODE pro<br />

SIMOCODE pro is the latest generation<br />

of Motor Management System<br />

(“Smart Overload”) bringing a new level<br />

of flexibility and functionality within the<br />

Siemens smart motor control center.<br />

By means of a PROFIBUS DP interface,<br />

it can easily be linked to higher-level<br />

automation systems. SIMOCODE pro<br />

implements all motor protection and<br />

control functions, determines operational,<br />

diagnostic and statistical data and<br />

organizes the communication between<br />

the automation system and MCC bucket.<br />

The SIMOCODE pro consists of two<br />

device series with different levels of<br />

functionality:<br />

SIMOCODE pro C (Compact)<br />

The compact motor management system<br />

can be used for Full Voltage Nonreversing<br />

(FVNR) starters, Full Voltage<br />

Reversing (FVR) starters, and base<br />

overload functionality.<br />

CT Module<br />

Keypad<br />

(Door Mounted)<br />

SIMOCODE pro C<br />

SIMOCODE pro V (Variable)<br />

The variable motor management system<br />

has an even greater range of functions,<br />

including voltage and power monitoring<br />

and expandable modules for additional<br />

I/O, as well as temperature and ground<br />

fault protection.<br />

CT Module<br />

Expandable Module<br />

SIMOCODE pro V<br />

Keypad<br />

(Door Mounted)<br />

Note: For detailed information on the SIMODE pro please<br />

contact the local Siemens Sales Office.<br />

16<br />

MOTOR CONTROL<br />

CENTERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 16-9


tiastar Motor Control Centers<br />

SIRIUS Soft Starters<br />

Components Overview<br />

16<br />

MOTOR CONTROL<br />

CENTERS<br />

SIRIUS Soft Starters<br />

Overview<br />

The advantages of the SIRIUS soft<br />

starters at a glance:<br />

• Soft starting and soft stop<br />

• Stepless starting<br />

• Reduction of current peaks<br />

• Avoidance of mains voltage fluctuations<br />

during starting<br />

• Reduced load on the power supply<br />

network<br />

• Reduction of the mechanical load in<br />

the operating mechanism<br />

• Considerable space savings and<br />

reduced wiring compared with<br />

mechanical reduced voltage starters<br />

• Maintenance-free switching<br />

• Fits perfectly in the SIRIUS modular<br />

system<br />

SIRIUS 3RW40<br />

SIRIUS 3RW40 soft starters include<br />

soft start and soft stop, and internal<br />

bypass. At the same time they come<br />

with additional functions, i.e. selectable<br />

solid-state motor overload, intrinsic<br />

device protection and adjustable current<br />

limiting, as well as a new patented<br />

two-phase control method (Polarity<br />

Balancing) that is unique in this rating<br />

range.<br />

SIRIUS 3RW40 soft starters are part<br />

of the SIRIUS modular system. This<br />

results in advantages such as identical<br />

sizes and a uniform connection system.<br />

Thanks to their particularly compact<br />

design, SIRIUS 3RW40 soft starters are<br />

only half as big as comparable wye-delta<br />

starters. Hence they can be mounted<br />

in compact space requirements in the<br />

control cabinet. Configuring and installation<br />

are carried out quickly and easily<br />

thanks to the 3-wire connection.<br />

SIRIUS 3RW40 for three-phase motors<br />

Soft starters rated up to 300 Hp (at 460<br />

V) for standard applications in threephase<br />

power systems. Extremely small<br />

sizes, low power losses and simple<br />

commissioning are just three of the<br />

many advantages of the SIRIUS 3RW40<br />

soft starters.<br />

Applicable standards<br />

• IEC 60947-2<br />

• UL/CSA #E143112<br />

Application areas<br />

• Fans<br />

• Pumps<br />

• Building/construction machines<br />

• Presses<br />

• Escalators<br />

• Transport systems<br />

• Air conditioning systems<br />

• Ventilators<br />

• Assembly lines<br />

• Operating mechanisms<br />

SIRIUS 3RW44<br />

In addition to soft starting and soft<br />

stopping, the solid-state SIRIUS 3RW44<br />

soft starters provide numerous functions<br />

for higher-level requirements.<br />

They cover a rating range up to 800Hp<br />

at 460 V in the inline circuit.<br />

The SIRIUS 3RW44 soft starters are<br />

characterized by a compact design<br />

for space-saving and clearly arranged<br />

control cabinet layouts. For optimized<br />

motor starting and stopping, the innovative<br />

SIRIUS 3RW44 soft starters are an<br />

attractive alternative with considerable<br />

savings potential compared to applications<br />

with a frequency converter. The<br />

new torque control and adjustable current<br />

limiting enable these high feature<br />

soft starters to be used in nearly every<br />

conceivable task. They reliably mitigate<br />

the sudden torque applications and current<br />

peaks during motor starting and<br />

stopping. This creates savings potential<br />

when calculating the size of the controlgear<br />

and when servicing the machinery<br />

installed. Be it for inline circuits or insidedelta<br />

circuits – the SIRIUS 3RW44 soft<br />

starter offers savings especially in terms<br />

of size and equipment costs.<br />

Combinations of various starting, operating<br />

and ramp-down possibilities ensure<br />

an optimum adaptation to the application<br />

specific requirements. Operating<br />

and commissioning can be performed<br />

by means of the user-friendly keypad<br />

and a menu prompted, multi-line graphic<br />

display with background lighting. The<br />

optimized motor ramp-up and rampdown<br />

can be effected by means of just<br />

a few settings with a previously selected<br />

language. Four-key operation and<br />

plain-text displays for each menu point<br />

guarantee full clarity at every moment<br />

of the parameterization and operation.<br />

Applicable standards<br />

• IEC 60947-4-2<br />

• UL/CSA #E143112<br />

Application areas, e.g.<br />

• Pumps<br />

• Mills<br />

• Ventilators<br />

• Saws<br />

• Compressors<br />

• Crushers<br />

• Water transport<br />

• Mixers<br />

• Conveying systems and lifts<br />

• Centrifuges<br />

• Hydraulics<br />

• Industrial cooling and refrigerating<br />

systems<br />

16-10<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


tiastar Motor Control Centers<br />

Variable Frequency Drives<br />

Components Overview<br />

MICROMASTER<br />

family of products<br />

MICROMASTER 440<br />

Application<br />

The MICROMASTER 440 inverter<br />

is suitable for a variety of variable-speed<br />

drive applications. Its flexibility provides<br />

for a wide spectrum of applications.<br />

These also include cranes and hoisting<br />

gear, high-bay warehouses, production<br />

machines for food, beverages and<br />

tobacco, packaging machines etc.; i.e.<br />

applications which require the<br />

frequency inverter to have a higher<br />

functionality and dynamic response than<br />

usual. The inverter is especially characterized<br />

by its customer-oriented<br />

performance and ease of use. Its large<br />

mains voltage range enables it to be<br />

used all over the world.<br />

Design<br />

The MICROMASTER 440 inverter<br />

has a modular design. The operator<br />

panels and modules can be easily<br />

exchanged.<br />

International standards<br />

n The MICROMASTER 440 inverter<br />

complies with the requirements of<br />

the EU low voltage guideline<br />

n The MICROMASTER 440 inverter has<br />

the marking<br />

n acc. to and c certified<br />

n c-tick<br />

Main characteristics<br />

n Easy, guided start-up<br />

n Modular construction allows maximum<br />

configuration flexibility<br />

n Six programmable isolated digital<br />

inputs<br />

n Two scaleable analog inputs (0 V to<br />

10 V, 0 mA to 20 mA) can also be<br />

used as a 7th/8th digital input<br />

n Two programmable analog outputs (0<br />

mA to 20 mA)<br />

n Three programmable relay outputs (30<br />

V DC/5 A resistive load; 250 V AC/2A<br />

inductive load)<br />

n Low-noise motor operation thanks<br />

to high pulse frequencies, adjustable<br />

(observe derating if necessary)<br />

n Complete protection for motor and<br />

inverter.<br />

Options (overview)<br />

n EMC filter, Class A/B<br />

n LC filter and sinusoidal filter<br />

n Line commutating chokes<br />

n Output chokes<br />

n Gland plates<br />

n Basic Operator Panel (BOP) for parameterizing<br />

the inverter<br />

n Plain text Advanced Operator Panel<br />

(AOP) with multi-language display<br />

n Communication modules<br />

– PROFIBUS<br />

– DeviceNet<br />

– CANopen<br />

n Pulse encoder evaluation module<br />

n PC connection kits<br />

n Mounting kits for installing the operator<br />

panels in the control cabinet doors<br />

n PC start-up tools executable under<br />

Windows 98 and NT/2000/ME/XP<br />

Professional<br />

n TIA integration with Drive ES<br />

16<br />

MOTOR CONTROL<br />

CENTERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 16-11


tiastar Motor Control Centers<br />

G120 Modular Converter<br />

Components Overview<br />

SINAMICS G120C<br />

SINAMICS G120C has been especially designed<br />

for an economic, space-saving and easy-to-operate<br />

frequency converter providing a multitude of functions.<br />

This device combines in particular compactness with<br />

superior power density and is characterized by fast<br />

installation and commissioning.<br />

16<br />

MOTOR CONTROL<br />

CENTERS<br />

Smallest size<br />

• Compact design (integrated braking chopper)<br />

• Fast mechanical installation (i.e. pluggable terminals)<br />

Easy to use<br />

• Simple, optimized commissioning with the<br />

STARTER tool<br />

• Effective, adequate parameter set (simple storing<br />

and cloning functions<br />

using IOP, BOP-2 or SD card)<br />

• Usable with IOP or BOP-2 operator panels<br />

Leading edge technology<br />

• Energy-efficient, encoder-less vector control -<br />

automatic flow reduction with V/F ECO<br />

• Safety Integrated (Safe Torque Off)<br />

• Communication PROFIBUS DP, PROFINET, CAN<br />

and USS/ Modbus RTU<br />

Application<br />

For industrial and commercial applications (secondary<br />

drive in production machines or generally for water/<br />

waste water, automotive). Application examples<br />

include mixers, extruders, simple pumps, fans,<br />

compressors, vibrator motors, simple wire drawing<br />

machines.<br />

Design<br />

SINAMICS G120C is a compact inverter where the Control Unit<br />

(CU) and Power Module (PM) function units are combined in<br />

one device. SINAMICS G120C can be integrated into the widest<br />

range of applications, either using the integrated digital and<br />

analog inputs or via the integrated fieldbus interface (available<br />

in the USS/ Modbus RTU, PROFINET, PROFIBUS DP, CANopen<br />

versions). Especially the product versions with integrated<br />

PROFIBUS DP or Profinet interface make full integration<br />

into the Siemens TIA family possible, therefore allowing the<br />

advantages of the seamless TIA product family to be fully<br />

utilized. SINAMICS G120C devices are preset in the factory so<br />

that they can be immediately connected to PROFIBUS DP or<br />

Profinet fieldbuses and used without parameterization.<br />

16-12<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


tiastar Motor Control Centers<br />

G120 Modular Converter<br />

Components Overview<br />

SINAMICS G120<br />

SINAMICS G120 is a modular drive inverter system that<br />

comprises various function units. These are essentially:<br />

Control Unit (CU) and Power Module (PM). The CU<br />

controls and monitors the PM and the connected motor<br />

in several operating modes that can be selected. It<br />

supports communication with a local or central controller<br />

and monitoring devices.<br />

• With many innovative functions<br />

Safety Integrated for safety-relevant machines and systems,<br />

capable of regenerative feedback into the line<br />

supply for energy saving<br />

• Fast commissioning<br />

STARTER tool and data backup using the BOP-2, IOP<br />

or MMC/SD card<br />

• Efficient and consistent solutions<br />

via Totally Integrated Automation (TIA), consistency<br />

from SINAMICS through to the automation level<br />

Application<br />

Machines and plants in industrial and commercial<br />

applications (machinery construction, automotive,<br />

textiles, chemical industry, printing, steel). Application<br />

examples include: Pumps and fans, Compressors,<br />

Centrifuges, Conveyor systems.<br />

Selecting the Power Module<br />

Power<br />

Module<br />

Control<br />

Unit<br />

Operator<br />

Panel<br />

Design<br />

16<br />

Power<br />

Module<br />

G_D011_EN_00354<br />

+<br />

Control<br />

Unit<br />

+<br />

Operator<br />

Panel<br />

SINAMICS G120<br />

standard inverters<br />

G_D011_XX_00356<br />

PM240 Power Modules<br />

PM240 Power Modules are suitable for many applications.<br />

The PM240 has an integrated braking chopper in frame sizes<br />

FSA up to FSF and has the possibility of connecting a braking<br />

resistor. For frame size FSGX, an optional pluggable braking<br />

module can be ordered.<br />

MOTOR CONTROL<br />

CENTERS<br />

Application-oriented design of SINAMICS G120<br />

SINAMICS G120 standard inverters are modular inverters<br />

for standard drives. Selection of the SINAMICS G120 is<br />

reduced to two or three steps thanks to the modular<br />

system used.<br />

PM250 Power Modules<br />

PM250 power modules are suitable for the same applications<br />

as the PM240, but they are specialized to address conveyorrelated<br />

applications - where the braking energy is directly<br />

fed back into the line supply using the unique technology of<br />

Efficient Infeed Technology. This feature provides the ability<br />

to feed energy back into the supply system in the generator<br />

mode (electronic braking) so that the energy in not wasted in<br />

a braking resistor.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 16-13


tiastar Motor Control Centers<br />

G120 Modular Converter<br />

Components Overview<br />

SINAMICS G120 (cont.)<br />

Selecting the Control Unit<br />

The optimum Control Unit is selected, based on the number<br />

of I/Os and any additional functions required such as Safety<br />

Integrated or HVAC. The communication options are already<br />

integrated and do not have to be additionally ordered or<br />

plugged in. Three product series are available corresponding<br />

to the particular application.<br />

Power<br />

Module<br />

Control<br />

Unit<br />

Operator<br />

Panel<br />

Selecting Optional System Components<br />

Intelligent Operator Panel IOP<br />

Graphic display with bar-type diagrams, e.g. for status values<br />

such as pressure or flow rate.<br />

Basic Operator Panel BOP-2<br />

Menu navigation and 2-line display permit fast and userfriendly<br />

commissioning of the inverter. Simple basic<br />

commissioning by simultaneously displaying parameter value,<br />

as well as the option of filtering parameters.<br />

Power<br />

Module<br />

Control<br />

Unit<br />

Operator<br />

Panel<br />

G_D011_XX_00355<br />

CU230 Control Units<br />

The CU230 Control Units have been specifically designed for<br />

pump, fan and compressor applications.<br />

G_D011_XX_00357<br />

16<br />

MOTOR CONTROL<br />

CENTERS<br />

CU240 Control Units<br />

The CU240 Control Units are suitable for a wide range of<br />

applications in a general machine construction, such as<br />

conveyor belts, mixers and extruders.<br />

CU250 Control Units<br />

The CU250 Control Unit is particularly suited for drives with<br />

high requirements in speed and torque accuracy.<br />

16-14<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


tiastar Motor Control Centers<br />

Power Monitoring<br />

Components Overview<br />

Power Monitoring<br />

Siemens line of power meters provides<br />

market leading technology for power<br />

quality measurement. These products<br />

continually change to meet growing<br />

needs for power quality and energy<br />

monitoring. Siemens tiastar MCCs<br />

are fully capable of installing any of<br />

Siemens power meters for your needs.<br />

PAC3200<br />

PAC4200<br />

PAC3100<br />

The SENTRON PAC3100 is a powerful<br />

compact power monitoring device<br />

that is suitable for use in industrial,<br />

government and commercial applications,<br />

where basic metering and energy<br />

monitoring is required. The meter may<br />

be used as a stand alone device monitoring<br />

over 25 parameters or as part of<br />

an industrial control, building automation<br />

or global power monitoring system.<br />

Metering and monitoring applications<br />

range from simple analog volt and amp<br />

meter replacements to stand-alone subbilling<br />

or cost allocation installations.<br />

The PAC3100 has many features not<br />

usually found in this price class of<br />

meters. A large graphical display supports<br />

multiple languages and easy to<br />

use menus that can be used to set up<br />

the meter. The meter also has built<br />

in Modbus RTU communications via<br />

a RS485 interface. The meter comes<br />

standard with two digital inputs and outputs.<br />

One output is suitable for pulse<br />

output for export/import real and reactive<br />

energy. The other output is controllable<br />

from an outside source by way of<br />

a Modbus register.<br />

PAC3200<br />

The SENTRON PAC3200 is a powerful<br />

compact power monitoring device<br />

that is suitable for use in industrial,<br />

government and commercial applications<br />

where basic metering and energy<br />

monitoring is required. The meter<br />

may be used as a stand alone device<br />

monitoring over 50 parameters or as<br />

part of an industrial control, building<br />

automation or global power monitoring<br />

system. Metering and monitoring<br />

applications range from simple analog<br />

volt and amp meter replacements to<br />

stand-alone sub billing or cost allocation<br />

installations with multiple tariffs.<br />

The SENTRON PAC3200 provides open<br />

communications using Modbus RTU/<br />

TCP, PROFIBUS-DP, and PROFINET<br />

protocols for easy integration into any<br />

local or remote monitoring system.<br />

Simple configuration of the meter can<br />

be done from the front display.<br />

PAC4200<br />

The SENTRON PAC4200 is a feature<br />

packed power monitoring device that<br />

is suitable for use in industrial, government<br />

and commercial applications<br />

where basic to advanced metering, logging,<br />

and I/O is required. The meter may<br />

be used as a stand alone device monitoring<br />

over 200 parameters or as part of<br />

an industrial control, building automation<br />

or global enterprise wide monitoring<br />

system.<br />

Advanced power quality monitoring and<br />

logging applications range from single<br />

low voltage breaker / building metering<br />

to sub-station main feeder monitoring,<br />

sub-billing or cost allocation installations<br />

with multiple tariffs. Whether your goal<br />

is to reduce operation cost, reduce your<br />

carbon footprint or to maintain your<br />

power assets, the PAC 4200 meter<br />

should be an important part of your<br />

power monitoring system.<br />

The SENTRON PAC4200 provides open<br />

communication using the standard builtin<br />

Ethernet Modbus TCP and has the<br />

capability of communicating through<br />

Optional Modbus RTU, PROFIBUS-DP,<br />

and PROFINET protocol modules simultaneously.<br />

This allows for easy integration<br />

into any local or remote monitoring<br />

system. The gateway functionality of<br />

this device reduces installation cost by<br />

replacing other gateway devices and<br />

simplifying wiring.<br />

16<br />

MOTOR CONTROL<br />

CENTERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 16-15


tiastar Motor Control Centers<br />

TPS3 Family of Hardwired Surge Protective Devices<br />

Product Overview<br />

TPS3 Integral or Internally Mounted SPDs for MCCs<br />

Siemens Integral TPS3s are UL 1449 4th Edition, factory installed SPDs within<br />

our MCCs, utilizing optimal electrical system connections to minimize impedance<br />

losses. This results in the some of the industry’s best “installed” Voltage Protection<br />

Ratings. This SPD has the following features:<br />

TPS3 01 Features<br />

n UL 1449 4th Edition and UL 1283<br />

n UL 1449-4 Type 2 SPD, UL 1283<br />

Listed, CSA 22.2 No. 269.2, Optional<br />

UL 1449 4th Edition Recognized<br />

Type 1, CSA 22.2<br />

n 20 kA l n (most models)<br />

n 200 kA SCCR (most models)<br />

n UL96A Lightening Protection Master<br />

Label Compliant<br />

n 100 –300 kA surge current capacity<br />

per phase<br />

n EMI/RFI filtering or Sine Wave<br />

tracking<br />

n Standard Monitoring –LEDs, audible<br />

alarm, dry contacts, surge counter,<br />

and ground references monitoring<br />

(GRM) diagnostics.<br />

n 10 year product warranty<br />

TPS3 01 Module<br />

16<br />

TPS3 01 MCC Installation<br />

MOTOR CONTROL<br />

CENTERS<br />

Ordering Information<br />

Catalog # TPS3 01 X 0 M<br />

Voltage Code<br />

A = 120/240 V, 1Ø, 3W<br />

B = 120/240 V, 3Ø, 4W<br />

C = 120/208 V, 3Ø, 4W<br />

D = 240 V, 3Ø, 3W<br />

E = 277/480 V, 3Ø, 4W<br />

F = 480 V, 3Ø, 3W<br />

G = 600 V, 3Ø, 3W (100kA & 150kA Only)<br />

K = 380/220 V, 3Ø, 4W<br />

L = 600/347 V, 3Ø, 4W<br />

S = 400/230 V, 3Ø, 4W<br />

Please consult the factory for applications<br />

requiring SPDs with larger per phase<br />

surge current capacities and/or 10-mode<br />

style configurations.<br />

Surge Current (kA)<br />

10 = 100 kA per phase<br />

15 = 150 kA per phase<br />

20 = 200 kA per phase<br />

25 = 250 kA per phase<br />

30 = 300 kA per phase<br />

- Example: TPS3C0120X0M = Type 4 SPD intended for use in Type 1<br />

applications, for a 208/120 V MCC with a surge current capacity of 200 kA<br />

per phase and a surge counter option<br />

- When an option is not selected, include a zero (0) in the field<br />

- Available Accessory: Ordered Separately<br />

RMSIE = Remote monitor<br />

2 = Type 2 SPD (Default) Includes<br />

UL 1283 EMI/RFI Filters<br />

0 = Type 1 SPD (Consult Factory<br />

Prior to Ordering)<br />

M = MCC Application<br />

X= Surge Counter<br />

16-16<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


tiastar Motor Control Centers<br />

Starter Ratings and Dimensions<br />

Selection Guide<br />

MCC Starter Ratings and Dimensions<br />

NEMA<br />

Size<br />

Maximum Horsepower Rating<br />

208V 230V 400V 460V 480V 600V<br />

Circuit Breaker Type (For Maximum HP at 460V) Fusible Type (For Maximum HP at 460V)<br />

MCP<br />

Frame<br />

Size<br />

(Amp)<br />

Dimensions<br />

in inches (mm)<br />

Unit Height <br />

W= Width, D= Depth<br />

kA<br />

Interrupting<br />

Rating at<br />

480V <br />

Standard<br />

Disconnect<br />

Sw/Fuse<br />

Clip Sizes<br />

Dimensions in inches (mm)<br />

Unit Height <br />

W= Width, D= Depth<br />

kA<br />

Interrupting<br />

Rating at<br />

480V <br />

Full Voltage Non-Reversing (FVNR) and Full Voltage Reversing (FVR) - UL Listed<br />

FVNR FVR IR Std/Opt FVNR FVR IR<br />

1 7.5 7.5 10 10 10 10<br />

12 (305) 18 (457)<br />

30/30 12 (305) 18 (457)<br />

2 10 15 25 25 25 25 125 12 (305) 24 (610) 60/60 12 (305) 24 (610)<br />

3 25 30 50 50 50 50 18 (457) 30 (762) 100/100 24 (610) 36 (914)<br />

4 40 50 75 100 100 100 125/250 24 (610) 36 (914) 42/100 200/200 42 (1067) 48 (1219)<br />

5 75 100 150 200 200 200 250/400 36 (914) 48 (1219)<br />

JD6<br />

MCS/ 400<br />

60 (1524) 60 (1524) 100<br />

6 150 200 300 400 400 400<br />

400/600/<br />

800<br />

7 — — — 600 600 600 1200<br />

Full Voltage Contactor (FVC)<br />

48 (1219)<br />

72 (1829)<br />

20W x 20D<br />

(508W x 508D)<br />

72 (1829)<br />

30W(762W)<br />

N/A 42/65<br />

MD6<br />

MCS/800<br />

ND6<br />

MCS/1200<br />

72 (1829)<br />

72 (1829)<br />

40W x 20D<br />

(1016W x 508D)<br />

72 (1829)<br />

30W (762W)<br />

N/A<br />

1<br />

2<br />

10.8<br />

16.2<br />

11.9<br />

17.9<br />

18.7<br />

31.2<br />

—<br />

—<br />

23.8<br />

35.8<br />

31<br />

46.7 125<br />

12 (305)<br />

12 (305)<br />

30/30<br />

60/60<br />

12 (305)<br />

12 (305)<br />

3 32 35 62 — 71 93 18 (457) 100/100 24 (610)<br />

4 48 54 94 — 107 140 125/250 24 (610) 100 200/200 42 (1067)<br />

5 108 119 206 — 238 311 250/400 36 (914)<br />

JXD6<br />

MCS/400<br />

60 (1524)<br />

6 198 218 346 — 437 570 600/800<br />

48 (1219)<br />

72 (1829)<br />

7 259 286 476 — 572 747 1200 72(1829) 65<br />

LXD6<br />

MCS/800<br />

NXD6<br />

MCS/1200<br />

72 (1829)<br />

30W ( 762W)<br />

72 (1829)<br />

50W 20D<br />

(1270W x 508D)<br />

100<br />

16<br />

Two Speed, Constant or Variable Torque — UL Listed<br />

2S2W 2S1W IR Std/Opt 2S2W 2S1W IR<br />

1 7.5 7.5 10 — 10 10<br />

24 (610) 24 (610)<br />

30/30 24 (610) 24 (610)<br />

2 10 15 25 — 25 25 125 24 (610) 24 (610) 60/60 24 (610) 24 (610)<br />

3 25 30 50 — 50 50 36 (914) 48 (1219) 100/100 30 (762) 36 (914)<br />

4 40 50 75 — 100 100 125/250 48 (1219) 60 (1524) 42/100 200/200 36 (914) 48 (1219) 100<br />

5 75 100 150 — 200 200 250/400<br />

72 (1829) 72 (1829)<br />

JD6 72 (1829) 72 (1829)<br />

30W (762W) 30W (762W)<br />

MCS/400 30W (762W) 30W (762W)<br />

6 150 200 300 — 400 400 600/800<br />

72 (1829)<br />

30W (672W)<br />

Consult<br />

Siemens<br />

MD6<br />

MCS/800<br />

72 (1829)<br />

40W (1016W)<br />

Consult<br />

Siemens<br />

MOTOR CONTROL<br />

CENTERS<br />

Two Speed, Constant Horsepower — UL Listed<br />

2S2W-CH 2S1W-CH IR Std/Opt 2S2W-CH 2S1W-CH IR<br />

1<br />

2<br />

5<br />

7.5<br />

5<br />

10<br />

7.5<br />

20<br />

—<br />

—<br />

7.5<br />

20<br />

7.5<br />

20 125<br />

24 (610)<br />

24 (610)<br />

24 (610)<br />

24 (610)<br />

30/30<br />

60/60<br />

24 (610)<br />

24 (610)<br />

24 (610)<br />

24 (610)<br />

3 20 25 40 — 40 40 30 (762) 36 (914) 100/100 36 (914) 48 (1219)<br />

4 30 40 50 — 75 75 125/250 36 (914) 48 (1219) 42/100 200/200 48 (1219) 60 (1524)<br />

5 60 75 100 — 150 150 250/400<br />

6 100 150 200 — 300 300 400/600<br />

72 (1829)<br />

30W (762W)<br />

72 (1829)<br />

30W (762W)<br />

72 (1829)<br />

30W (762W)<br />

Consult<br />

Siemens<br />

JD6<br />

MCS/ 400<br />

MD6<br />

MCS/800<br />

72 (1829)<br />

30W (672W)<br />

72 (1829)<br />

40W (1016W)<br />

72 (1829)<br />

30W (672W)<br />

Consult<br />

Siemens<br />

100<br />

The addition of oversized CPTs (above 50VA), relays, timers, etc. may increase unit height.<br />

For other available voltage ratings, consult Siemens.<br />

Interrupting ratings are 25kAIC when not UL listed.<br />

Fixed mounted units (not plug-in).<br />

Note: For half size starters, contact Siemens.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 16-17


tiastar Motor Control Centers<br />

Starter Ratings and Dimensions<br />

Selection Guide<br />

MCC Starter Ratings and Dimensions (cont.)<br />

NEMA<br />

Size<br />

Maximum Horsepower Rating<br />

208V 230V 400V 460V 480V 600V<br />

Circuit Breaker Type (For Maximum HP at 460V) Fusible Type (For Maximum HP at 460V)<br />

Standard<br />

Breaker<br />

Type<br />

Dimensions<br />

in inches (mm)<br />

Unit Height <br />

W= Width, D= Depth<br />

kA<br />

Interrupting<br />

Rating at<br />

480V <br />

Standard<br />

Disconnect<br />

Sw/Fuse<br />

Clip Sizes<br />

Dimensions in inches (mm)<br />

Unit Height <br />

W= Width, D= Depth<br />

kA<br />

Interrupting<br />

Rating at<br />

480V <br />

Reduced Voltage Autotransformer (RVAT) Non-Reversing, Closed Transition — UL Listed<br />

2 10 15 25 — 25 25<br />

MCP<br />

RVAT IR Std/Opt RVAT IR<br />

42 (1067) 100/100 48 (1219)<br />

3 25 30 50 — 50 50 48 (1219) 200/200 60 (1524)<br />

4 40 50 75 — 100 100<br />

5 75 100 150 — 200 200<br />

72 (1829)<br />

30W (762W)<br />

72 (1829)<br />

30W (762W)<br />

6 150 200 300 — 400 400 Consult Siemens<br />

7 — — — — 600 600 ND6<br />

72 (1829)<br />

20W x 20D (508W x 508D)<br />

Reduced Voltage Wye Delta, Open and Closed Transition<br />

JD6MCS/<br />

400<br />

MD6MCS/<br />

800<br />

ND6MCS/<br />

1200<br />

ND6MCS/<br />

1200<br />

72 (1829)<br />

30W (762W)<br />

72 (1829)<br />

30W (762W)<br />

Consult Siemens<br />

72 (1829)<br />

40W x 20D (1016W x 508D)<br />

YDO YDC IR Std/Opt YDO YDC IR<br />

2 20 25 25 — 40 40<br />

30 (762) 42 (1067)<br />

100/100 36 (914) 48 (1219)<br />

3 25 30 50 — 75 75 36 (914) 48 (1219) 200/200 48 (1219) 60 (1524)<br />

4 60 60 75 — 150 150 MCP 36 (914) 48 (1219) 42/100 JD6MCS/<br />

400<br />

72 (1829) 72 (1829)<br />

5 150 150 150 — 300 300<br />

72 (1829)<br />

30W (672W)<br />

72 (1829)<br />

30W (672W)<br />

LD6MCS/<br />

600<br />

72 (1829) 30W<br />

(672W)<br />

72 (1829)<br />

30W (672W)<br />

100<br />

16<br />

MOTOR CONTROL<br />

CENTERS<br />

NEMA<br />

Size<br />

Maximum Horsepower Rating<br />

208V 230V 400V 460V 480V 600V<br />

Circuit Breaker Type<br />

MCP<br />

Frame<br />

Size<br />

Dimensions<br />

in inches (mm)<br />

Unit Height <br />

kA Interrupting<br />

Rating at 480V <br />

Dual Full Voltage Non-Reversing (DFVNR) Unit with Circuit Breaker<br />

1 7.5 7.5 10 — 10 10 125 18 (457) 100<br />

Compact Units Available – High Density FVNR<br />

1 7.5 7.5 — — 10 —<br />

2 10 15 — — 25 — 125<br />

6 (152)<br />

3 25 30 — — 50 — 12 (305)<br />

4 40 50 — — 100 — 125/250 18 (457)<br />

100<br />

Compact Units Available – High Density FVC<br />

NEMA<br />

Size 208V 230V 400V 460V 480V 600V<br />

1 9.7 10.7 — — 22 —<br />

2 16.2 17.9 — — 37 —<br />

6 (152)<br />

3 32 35.8 — — 74 — 12 (305)<br />

4 48 54 — — 112 — 18 (457)<br />

Dimensions in inches (mm)<br />

Unit Height <br />

kA Interrupting<br />

Rating at 480V <br />

100<br />

The addition of oversized CPTs (above 50VA), relays, timers, etc. may increase unit height.<br />

For other available voltage ratings, consult Siemens.<br />

Interrupting ratings are 25kAIC when not UL listed.<br />

Fixed mounted units (not plug-in).<br />

The addition of relays, timers, etc. will increase unit height.<br />

16-18<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


tiastar Motor Control Centers<br />

Starter Ratings and Dimensions<br />

Selection Guide<br />

SINAMICS G120C- Technical Data<br />

Output Ratings Dimensions - in. (mm) a IR<br />

Frame<br />

Size<br />

LO-OL<br />

A<br />

LO-OL<br />

hp<br />

HI-OL<br />

A<br />

HI-OL<br />

hp<br />

A 1.4 0.5 1.1 0.5<br />

A 1.9 0.75 1.4 0.5<br />

A 2.6 1 1.9 0.75<br />

A 3.5 2 2.6 1<br />

A 4.8 2 3.5 2<br />

A 6.2 3 4.8 2<br />

A 7.5 3 6.2 3<br />

B 10.6 5 7.5 3<br />

B 14.0 10 10.6 5<br />

C 21.3 15 14.0 10<br />

C 26.4 15 21.3 15<br />

C 31.5 20 26.4 15<br />

Circuit Breaker, Reactor (Line or Load) and Drive Included.<br />

Mounting<br />

Height<br />

18 (457)<br />

24 (610)<br />

30 (762)<br />

Structure<br />

W x D<br />

20 x 15<br />

(508 x 381)<br />

65ka<br />

SINAMICS G120 Technical Data<br />

Output Ratings Dimensions - in. (mm) a IR<br />

Frame<br />

Size<br />

LO-OL<br />

A<br />

LO-OL<br />

hp<br />

HI-OL<br />

A<br />

HI-OL<br />

hp<br />

A 1.2 0.5 1.3 0.5<br />

A 1.6 0.5 1.7 0.75<br />

A 2.0 0.75 2.2 1<br />

A 2.9 1 3.1 1.5<br />

A 3.8 2 4.1 2<br />

B 5.5 3 5.9 3<br />

B 7.2 3 7.7 5<br />

B 9.5 5 10.2 5<br />

C 16.7 10 13.2 7.5<br />

C 23.3 15 19 10<br />

C 29.8 20 26 15<br />

D 35.3 25 32 20<br />

D 41.9 30 38 25<br />

D 55.8 40 45 30<br />

E 69.8 50 60 40<br />

E 83.7 60 75 50<br />

F 102.3 75 90 60<br />

F 134.9 100 110 75<br />

F 165.5 125 145 100<br />

F 190.7 150 178 125<br />

F 240.0 150 200 150<br />

Gx 264.3 200 250 200<br />

Gx 323.8 250 302 250<br />

Gx 417.4 350 370 300<br />

D 35.3 25 32 20<br />

D 41.9 30 38 25<br />

D 55.8 40 45 30<br />

E 69.8 50 60 40<br />

E 83.7 60 75 50<br />

F 102.3 75 90 60<br />

F 134.9 100 110 75<br />

F 165.5 125 145 100<br />

1 Circuit Breaker, Reactor (Line or Load) and Drive Included.<br />

2 Fixed Mounted<br />

PM240<br />

PM250<br />

Mounting<br />

Height<br />

18 (457)<br />

24 (610)<br />

36 (914)<br />

48 (1219)<br />

60 (1624)<br />

72 (1829)<br />

48 (1219)<br />

60 (1624)<br />

72 (1829)<br />

Structure<br />

W x D<br />

20 x 15<br />

(508 x 381)<br />

20 x 15 <br />

(508 x 381)<br />

20 x 20 <br />

(508 x 508)<br />

40 x 20 <br />

(1016 x 508)<br />

20 x 15 <br />

(508 x 381)<br />

20 x 20 <br />

(508 x 508)<br />

65ka<br />

16<br />

MOTOR CONTROL<br />

CENTERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 16-19


tiastar Motor Control Centers<br />

Starter Ratings and Dimensions<br />

Selection Guide<br />

16<br />

MOTOR CONTROL<br />

CENTERS<br />

480V Solid State Reduced Voltage —<br />

NEMA 1 MCC Enclosures <br />

Rating<br />

HP RVSS Type Rated<br />

Amperes<br />

5 3RW40 9<br />

10 3RW40 19<br />

15 3RW40 24<br />

20 3RW40 28<br />

25 3RW40 34<br />

30 3RW40 42<br />

40 3RW40 58<br />

50 3RW40 70<br />

75 3RW40 117<br />

100 3RW40 145<br />

150 3RW40 205<br />

Dimensions - In. (mm) <br />

Mounting<br />

Height<br />

18 (457)<br />

24 (610)<br />

36 (914)<br />

200 3RW40 315<br />

48 (1219) <br />

300 3RW40 385 72 (1829) <br />

15 3RW44 26<br />

Structure<br />

WxD<br />

20 x 15<br />

(508 x 381)<br />

20 3RW44 32<br />

100<br />

25 3RW44 42<br />

30 3RW44 52<br />

40 3RW44 68 36 (914)<br />

50 3RW44 82<br />

60 3RW44 100<br />

75 3RW44 117<br />

100 3RW44 145<br />

125 3RW44 180<br />

150 3RW44 215 48 (1219) <br />

200 3RW44 280<br />

250 3RW44 385<br />

400 3RW44 494<br />

450 3RW44 562 72 (1829) 30 x 15<br />

500 3RW44 693<br />

(762 x 381)<br />

600 3RW44 850 65<br />

750 3RW44 970 Consult Siemens<br />

800 3RW44 1076 Consult Siemens<br />

42<br />

For other available voltage ratings, consult Siemens.<br />

For other enclosure types, consult Siemens.<br />

Ratings are based on CLASS 20 overloads and 6 starts per Hour. Consult Siemens for<br />

other applications.<br />

Dimensions shown are for circuit breaker or fusible disconnects.<br />

RVSS with bypass and / or isolation contactors require extra mounting space. Consult<br />

Siemens for further information.<br />

3RW40 Units include line side isolation contactor<br />

Fixed mounted units (not plug-in).<br />

IR<br />

480V Variable Frequency Drives —<br />

NEMA 1A MCC Enclosures <br />

Rating<br />

HP <br />

Drive<br />

Type<br />

Rated<br />

Amperes<br />

Dimensions - In. (mm) <br />

Mounting<br />

Height<br />

2<br />

4 18 (457)<br />

5 10.2<br />

24 (610)<br />

7.5 16<br />

10 18.4<br />

15 26 36 (914)<br />

20 32<br />

25 38 48 (1219) <br />

30 45<br />

MM440<br />

40 62 48 (1219) <br />

60 (1524) <br />

75 110<br />

50 76<br />

60 90<br />

Structure<br />

W x D<br />

20 x 15<br />

(508 x 381)<br />

100 145<br />

125 178<br />

150 205 30 x 15<br />

200 250<br />

72 (1829) 20 x 15<br />

(508 x 381)<br />

600V Variable Frequency Drives —<br />

NEMA 1A MCC Enclosures <br />

Rating<br />

HP <br />

Drive<br />

Type<br />

Rated<br />

Amperes<br />

2<br />

5<br />

2.7<br />

6.1<br />

7.5 9<br />

10 11<br />

15 17<br />

20 22<br />

25 27<br />

MM440<br />

30 32<br />

40 41<br />

50 52<br />

60 62<br />

75 77<br />

100 99<br />

125 125<br />

(762 x 381)<br />

For other available voltage ratings, consult Siemens.<br />

For other enclosure types, consult Siemens.<br />

Ratings are for Variable Torque applications. Consult Siemens for other applications.<br />

Dimensions shown are for circuit breaker or fusible disconnects except as noted.<br />

Fusible disconnect unit is larger, consult Siemens.<br />

Drives with bypass and / or isolation contactors require extra mounting space.<br />

Consult Siemens for further information.<br />

Fixed mounted units (not plug-in).<br />

Dimensions - In. (mm) <br />

Mounting<br />

Height<br />

24 (610)<br />

48 (1219) <br />

60 (1624) <br />

Structure<br />

W x D<br />

20 x 15<br />

(508 x 381)<br />

72 (1829) 20 x 15 <br />

IR<br />

100<br />

IR<br />

100<br />

For other available voltage ratings, consult Siemens.<br />

For other enclosure types, consult Siemens.<br />

Ratings are for Variable Torque applications. Consult Siemens for other applications.<br />

Dimensions shown are for circuit breaker or fusible disconnects except as noted.<br />

Fusible disconnect unit is larger, consult Siemens.<br />

Drives with bypass and / or isolation contactors require extra mounting space.<br />

Consult Siemens for further information.<br />

Fixed mounted units (not plug-in).<br />

16-20<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


tiastar Motor Control Centers<br />

Power Distribution Ratings and Dimensions<br />

Selection Guide<br />

Lighting Panelboards<br />

Applied in MCCs<br />

Amp<br />

Rating<br />

Main Lug Only<br />

125/250<br />

Number<br />

of Circuits<br />

Main Circuit Breaker<br />

125/250<br />

Height in Inches (mm)<br />

1%, 3W<br />

240/120<br />

3%, 4W<br />

208Y/120<br />

3%, 4W<br />

277/480<br />

18 30 (762) 30 (762) 30 (762)<br />

30 36 (914) 36 (914) 36 (914)<br />

42 42 (1067) 42 (1067) 42 (1067)<br />

18 30 (762) 30 (762) 30 (762)<br />

30 36 (914) 36 (914) 36 (914)<br />

42 42 (1067) 42 (1067) 42 (1067)<br />

Distribution Transformers<br />

KVA Rating<br />

1<br />

1.5<br />

2<br />

3<br />

5<br />

7.5<br />

10<br />

15<br />

25<br />

30<br />

37.5<br />

45<br />

9<br />

15<br />

25<br />

30<br />

37.5<br />

45<br />

Phase<br />

1<br />

Unit Height in<br />

Inches (mm)<br />

12 (305) <br />

18 (457) <br />

24 (610) <br />

36 (914) <br />

3 18 (457)<br />

24 (610)<br />

Plate mounted.<br />

Transformer mounted on brackets 6 in.<br />

(152 mm) off sills.<br />

Requires 20 in. (508 mm) deep structure.<br />

16<br />

MOTOR CONTROL<br />

CENTERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 16-21


tiastar Motor Control Centers<br />

Product History<br />

Aftermarket<br />

Siemens has an installed base of motor<br />

control centers dating back to 1964<br />

due to acquisitions of Allis-Chalmers<br />

in 1978, ITE Gould in 1983 and Furnas<br />

Electric in 1996. This has resulted in<br />

eleven MCC models installed across<br />

the United States. Replacement units<br />

for these models as well as the current<br />

tiastar MCC offerings are built in<br />

the Siemens West Chicago plant.<br />

Siemens developed this tool to help<br />

people gain a better understanding of<br />

the wide variety of this installed base<br />

of MCCs. This should enable people<br />

to order aftermarket buckets or new<br />

MCCs much easier. In this program<br />

brochure, all the tools necessary<br />

for identifying existing MCCs to<br />

ordering forms are included. All items<br />

listed as follows: timeline, product<br />

overview, identification guide, product<br />

descriptions, work sheets and ordering<br />

check sheet. The intent of this guide is<br />

to provide a tool for Siemens customers<br />

so they can make a more educated<br />

purchasing decision. If you have any<br />

questions, please contact your local<br />

Siemens representative.<br />

MCC Timeline<br />

ITE<br />

Allis-Chalmers<br />

Furnas<br />

ITE<br />

16<br />

Allis-Chalmers<br />

MOTOR CONTROL<br />

CENTERS<br />

Siemens-Allis<br />

Furnas<br />

Siemens<br />

Siemens<br />

Siemens-Furnas<br />

Siemens<br />

Siemens<br />

Siemens<br />

1964 1965 1971 1972 1975 1979 1980 1986 1990 1992 1993 1995 1996 1997 2001 2002 >2002<br />

Year<br />

Note: Timeline represents approximate values<br />

16-22<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


tiastar Motor Control Centers<br />

Product History<br />

Aftermarket<br />

This overview is a clear and concise snap shot of Siemens<br />

entire MCC product offering. For your convenience, typical<br />

MCC part numbers are shown for continued identification<br />

possibilities.<br />

Furthermore, the overview covers the standard options for the<br />

product offering.<br />

Original<br />

manufacturer<br />

Model<br />

Production Bucket w/<br />

dates door & handle <br />

Factory<br />

retrofit <br />

Typical MCC<br />

number <br />

Siemens tiastar 2002 – Current X — Same as System89<br />

Siemens/Furnas System89 1980 – 2001 X — 89BFXX### ###<br />

89BSXX### ###<br />

89BBXX### ###<br />

WX### (ex. WU760)<br />

Siemens Model 95 + 1997 – 2001 X — 95BFXX### ###<br />

95BSXX### ###<br />

95BBXX### ###<br />

XX### (ex. WU760)<br />

Siemens Model 95 1995 – 1997 X — 09-001-XXXX-XXXXX-XXX<br />

Siemens Model 90 1990 – 1997 X — 30-001-XXXX-XXXXX<br />

Siemens Allis Marq 21 1975 – 1990 X — 01-14XX-XXXXX-XX<br />

Allis-Chalmers Mark 2 1972 – 1975 X — ##### (ex. 15375)<br />

Allis-Chalmers Mark 1 1965 – 1972 X —<br />

ITE Gould 5600 1971 – 1992 — X 84-XXXXX-XX<br />

ITE Gould 9600 1964 – 1971 — X 85-XXXXX-XX<br />

86-XXXXX-XX<br />

Furnas Class89 1965 – 1979 — X 89FVXXXX XXX<br />

89SVXXXX XXX<br />

89BVXXXX XXX<br />

V#### (ex. V2176)<br />

Dates represent approximate values only.<br />

Buckets exceeding 250 amps are fix mounted.<br />

Contact West Chicago Aftermarket Dept. for Retrofit Program at (800) 683-6200.<br />

In some instances, a generic 5 alphanumeric number is designed as the MCC sales order number. In most cases a 5 alphanumeric number within the<br />

MCC number is the sales order number. MCC numbers can be found inside the MCC bucket.<br />

Starters<br />

208V, 230V, 400V, 480V, 600V NEMA size<br />

FVNR 1-7<br />

FVR 1-7<br />

DFVNR 1<br />

2S1W-CT 1-6<br />

2S1W-VT 1-6<br />

2S2W-CT 1-6<br />

2S2W-VT 1-6<br />

RVAT 2-7<br />

RVSS<br />

Consult factory<br />

VFD<br />

Consult factory<br />

YDC/YDO 2-5<br />

Standard options<br />

Amp meter + CT<br />

CT<br />

Voltage monitor<br />

Vac. contactor<br />

Transducer<br />

Fuse puller<br />

Bypass<br />

ASI®<br />

Ground fault<br />

Elapse time meter<br />

Surge suppression<br />

Under voltage CB<br />

Shunt trip<br />

Ground stab<br />

High density bucket<br />

Special paint<br />

Timer<br />

4P relay<br />

Extra unit space<br />

X=Letter<br />

# = Number<br />

16<br />

MOTOR CONTROL<br />

CENTERS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 16-23


tiastar Motor Control Centers<br />

MCC Quote Request Form<br />

Aftermarket<br />

Aftermarket and Replacement units forms are available at www.usa.siemens.com/mcc on the aftermarket page.<br />

MOTOR CONTROL<br />

CENTERS<br />

16<br />

16-24<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Control Products<br />

SPEEDFAX TM<br />

Section<br />

Class 14<br />

Class 17, 18<br />

Class<br />

82, 83, 84,<br />

87, 88<br />

Class LE,<br />

LC, CLM<br />

Scan to connect<br />

online to the<br />

most up-todate<br />

version of<br />

this Section of<br />

SPEEDFAX.<br />

N E M A & G e n e r a l P u r p o s e C o n t r o l<br />

Product Overview 17-5<br />

Manual Control<br />

Fractional HP Starters, Class SMF 17-6 - 17-7<br />

Switches, Class MMS and MRS 17-8 - 17-9<br />

Starters and Switches, Class 11 - 3RV 17-10 - 17-11<br />

NEMA Control<br />

Catalog Numbering System 17-12<br />

Non-Combination Starters Features and Benefits 17-13 - 17-14<br />

Non-Reversing Starters, Class 14 17-15 - 17-16<br />

Combination Starters Features and Benefits 17-17<br />

Combination Starters, Class 17 and 18 17-18 - 17-23<br />

Reversing Starters, Class 22 17-24<br />

Combination Reversing Starters, Class 25 and 26 17-25 - 17-26<br />

Two Speed Starters Features and Benefits 17-27<br />

Two Speed Starters, Class 30 17-28 - 17-29<br />

Combination Two Speed Starters, Class 32 17-30 - 17-33<br />

Reduced Voltage Control<br />

Reduced Voltage Features and Benefits 17-34<br />

Auto Transformer Starters, Class 36 and 37 17-35 - 17-38<br />

Part Winding Starters, Class 36 and 37 17-39 - 17-42<br />

Wye Delta Open Transition, Class 36 and 37 17-43 - 17-46<br />

Wye Delta Closed Transition, Class 36 and 37 17-47 - 17-50<br />

Heavy Duty Contactors<br />

Non-Reversing Contactors, Class 40 17-51 - 17-52<br />

Vacuum Contactors, 17-51<br />

Reversing Contactors, Class 43 17-53<br />

Definite Purpose Contactors 17-54 - 17-60<br />

Overload Relays<br />

Class 48, 958 and 3RB20 17-62 - 17-65<br />

Duplex Controllers<br />

Features and Benefits 17-66<br />

Non Combination, Class 83 17-67<br />

Combination, Class 84 17-68 - 17-69<br />

Pump Control Panels<br />

Slim Line NEMA Pump Controller for Agricultural, Class 82 17-70 - 17-73<br />

Class 87 and 88 Features and Benefits 17-74 - 17-75<br />

Full-Voltage Type, Class 87 17-76<br />

Vacuum Starter Type, Class 87 17-77<br />

Reduced-Voltage Type, Class 88 17-78 - 17-79<br />

Lighting Control<br />

Electrically Held Contactors, Class LE 17-81 - 17-86<br />

Electrically Held Contactors, Class LC 17-87 - 17-91<br />

Mechanically Held Contactors, Class CLM 17-92 - 17-94<br />

Control Power Transformers<br />

Domestic and International (UL, CSA, CE) Class MT, MTG 17-95 - 17-99<br />

Modifications and Drawings<br />

Field Modification Kits 17-100 - 17-110<br />

Enclosure Kits 17-111 - 17-113<br />

Factory Modifications 17-114 - 17-118<br />

Dimensions 17-126 - 17-154<br />

Wiring Diagrams 17-155 - 17-175<br />

Replacement Parts<br />

SMF Manual Starter Heater Elements 17-119<br />

NEMA Coils and Contact Kits 17-120 - 17-121<br />

Coil VA Ratings and Overload Relays 17-122<br />

Lighting Contactor Parts and Kits 17-123<br />

(continued on next page)<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

(Section was last modified on 10/07/20)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-1


Control Products<br />

SPEEDFAX TM<br />

Section<br />

Motor Starters, Soft Starters and Load Feeders<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

3RE4<br />

3RW40<br />

3RW44<br />

Class 73/74<br />

Enclosed IEC Controls<br />

General information and catalog numbering system 17-176 - 17-177<br />

Enclosed starters 17-178 - 17-180<br />

Enclosed contactors 17-181 - 17-182<br />

Overload Relay 17-183<br />

Field modifications and accessories 17-184 - 17-188<br />

Circuit diagrams 17-189<br />

Dimension drawings 17-190 - 17-192<br />

For Operation in the Control Cabinet 3RW Soft Starters<br />

Introduction 17-193<br />

General data 17-194<br />

3RW30 for standard applications<br />

Overview 17-195<br />

Application 17-195<br />

Selection and ordering data 17-196<br />

Accessories 17-197<br />

Application examples 17-198<br />

Function 17-235<br />

Technical specifications 17-236 - 17-245<br />

Dimensional drawings 17-282<br />

Schematics 17-287<br />

3RW40 for standard applications<br />

Overview 17-199<br />

Application 17-199<br />

Selection and ordering data 17-200 - 17-202<br />

Accessories 17-203 - 17-204<br />

Application examples 17-205<br />

Function 17-246<br />

Technical specifications 17-247 - 17-260<br />

Dimensional drawings 17-283<br />

Schematics 17-288 - 17-289<br />

3RW44 for high-feature applications<br />

Configuration 17-206<br />

Overview 17-207<br />

Application 17-207<br />

Selection and ordering data 17-208 - 17-210<br />

Sirius ES engineering software 17-211 - 17-215<br />

Accessories 17-216 - 17-217<br />

Application examples 17-218 - 17-220<br />

Function 17-261<br />

Technical specifications 17-262 - 17-281<br />

Dimensional drawings 17-284 - 17-285<br />

Schematics 17-290 - 17-293<br />

Class 73/74 Enclosed Softstarter applications<br />

Overview 17-221<br />

Application 17-221<br />

Selection and ordering data 17-77 - 17-233<br />

Factory Modifications 17-234<br />

Dimensional drawings 17-286<br />

Schematics 17-294<br />

17-2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Control Products<br />

SPEEDFAX TM<br />

Section<br />

Pilot Devices<br />

Class 50<br />

Class 51<br />

SIRIUS ACT 3SU Series<br />

Overview 17-295 - 17-296<br />

For more information on the SIRIUS ACT 3SU product line,<br />

please see Section 10 of the US Industrial Controls catalog<br />

Class 52 30.5mm Mounting Diameter Pilot Devices<br />

Introduction 17-297<br />

Momentary Push Button, Non-Illuminated 17-298 - 17-299<br />

2 & 3 Position Push-Pull Mushroom Head Devices,<br />

Non-Illuminated 17-300 - 17-301<br />

2 & 3 Position Push-Pull Mushroom Head Devices,<br />

Illuminated 17-302 - 17-303<br />

2 Position Twist-to-Release Mushroom Head Devices,<br />

Non-Illuminated 17-304<br />

2 Position Twist-to-Release Mushroom Head Devices, Illuminated 17-305<br />

Indicator Light 17-306 - 17-307<br />

Push Button & Push-to-Test, Illuminated 17-308 - 17-309<br />

Push Button Mushroom Head Devices,Illuminated 17-310<br />

Selector Switches, Illuminated 17-311<br />

Selector Switch Short & Long Lever, Non-Illuminated 17-312 - 17-313<br />

Keyed Selector Switch 17-314 - 17-315<br />

Selector Push Button 17-317<br />

Special Devices 17-318<br />

Cam Selection Guide for Selector Switch, Keyed<br />

Selector Switch and Selector Pushbutton 17-319<br />

Custom Selector Switch Designs 17-320<br />

Accessories and Spare Parts 17-321 - 17-324<br />

Dimensional Drawings 17-325 - 17-328<br />

Break Glass and EPO Pushbutton Stations 17-329<br />

Class 52 30.5mm Enclosed Pushbutton Stations<br />

Assembled Enclosures with Standard Devices 17-330 - 17-331<br />

P30 Empty Enclosures Only 17-332<br />

Enclosure Legend Plates 17-333<br />

Enclosure Dimensions 17-334<br />

Technical Specifications 17-335<br />

Retail Packaging Convenience Center 17-336 - 17-337<br />

Pilot Devices<br />

17 CONTROL<br />

PRODUCTS<br />

Class 52<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-3


Control Products<br />

NEMA & General Purpose Controls<br />

Revised on 03/31/20<br />

Controls Express<br />

Starters at the speed you need<br />

Siemens NEMA starters, pump panels and lighting<br />

contactors are known for their dependability and ruggedness,<br />

and now they are delivered faster than ever before<br />

through Controls Express.<br />

Controls Express puts our most popular products in your<br />

hands faster, because we stock more products across our<br />

entire product line. Our Class 14 NEMA starters, Class 87<br />

pump panels, and LC & LE lighting contactors are now<br />

available in stock for immediate or next day shipping.<br />

In addition, thousands of our open and enclosed starters<br />

can now be built-to-order and shipped in 1-3 days through<br />

Controls Express.<br />

Siemens is committed to making your job easier by stocking<br />

more products, offering more configurations, expediting<br />

factory modifications, and delivering industry leading<br />

turnaround times on our most requested control products.<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

To quickly identify products that are part of Controls<br />

Express and therefore available in 3 days or less, applicable<br />

catalog numbers have a light blue background.<br />

See the appropriate selection pages listed below.<br />

Class 14 NEMA Starters see pages 17-15 & 17-16<br />

Class 17 NEMA Combination Starters see pages 17-18<br />

& 17-20. For quick ship versions with factory<br />

modifications see on-line at<br />

www.usa.siemens.com/controls-express<br />

Class 18 NEMA Combination Starters see page 17-22.<br />

Class 40 NEMA Contactors see page 17-51<br />

Class 87 Pump Panels see page 17-76<br />

LE Lighting Contactors see page 17-83<br />

LC Lighting Contactors see page 17-89 & 17-90<br />

Controls Express lead times apply to orders of up to<br />

6 units of the Class 14, Class 87, LC, or LE. Please<br />

contact customer service at 1-866-663-7324 for lead<br />

times of larger order volumes.<br />

For more information on Controls Express and a<br />

complete list of available products, please visit our<br />

website at www.usa.siemens.com/controls-express<br />

17-4<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Control Products<br />

NEMA & General Purpose Controls<br />

Revised on 03/31/20<br />

Product Overview<br />

Class SMF<br />

Fractional Horsepower<br />

Manual Starters<br />

Page 17-6<br />

Class MMS & MRS<br />

Fractional Horsepower<br />

Manual Switches<br />

Page 17-8<br />

Class 11<br />

Manual Starters and<br />

Switches<br />

Page 17-10<br />

Class 14<br />

NEMA Starters<br />

Page 17-15<br />

Class 17, 18<br />

NEMA Combination<br />

Starters<br />

Page 17-18<br />

Class 22<br />

NEMA Reversing<br />

Starters<br />

Page 17-24<br />

Class 25, 26<br />

NEMA Combination<br />

Reversing Starters<br />

Page 17-25<br />

Class 30<br />

NEMA Multi-Speed<br />

Starters<br />

Page 17-28<br />

Class 32<br />

NEMA Combination<br />

Multi-Speed Starters<br />

Page 17-30<br />

Class 36, 37<br />

Reduced Voltage<br />

Electromechanical<br />

Starters<br />

Page 17-34<br />

NEMA & General<br />

Purpose Control<br />

Class 40<br />

NEMA Contactors<br />

and Vacuum Contactors<br />

Page 17-51<br />

Class 43<br />

NEMA Reversing<br />

Contactors<br />

Page 17-53<br />

Class 42, 45<br />

Definite Purpose<br />

Contactors<br />

Page 17-54<br />

Class 48, 958, 3RB20<br />

Overload Relays<br />

Page 17-61<br />

Class 82, 83, 84,<br />

87, 88<br />

Pump Controls<br />

Page 17-70<br />

17 CONTROL<br />

PRODUCTS<br />

Class LE, LC, CLM<br />

Lighting Contactors<br />

Page 17-81<br />

Class MT, MTG<br />

Control Power<br />

Transformers<br />

Page 17-95<br />

Modifications and<br />

Drawings<br />

Page 17-100<br />

Heater Tables and<br />

Replacement Parts<br />

Page 17-119<br />

3RE4 Enclosed IEC<br />

motor controllers<br />

Page 17-176<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-5


Manual Control<br />

Fractional HP Starters, Class SMF<br />

General<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Class SMF<br />

Class SMF fractional horsepower starters<br />

provide overload protection as<br />

well as manual on-off control for small<br />

horsepower motors in a variety of<br />

industrial and commercial applications.<br />

Available in one or two pole versions,<br />

these devices are suitable for use with<br />

AC single phase motors up to 1 HP.<br />

Two pole starters can also be used<br />

with DC motors up to 3 ⁄4 HP. Typical<br />

applications include fans, conveyors,<br />

pumps, and small machine tools.<br />

Continuous Current Rating<br />

16 amperes.<br />

Overload Trip Assembly<br />

Motor protection is provided by a Class<br />

SMFH heater element which must be<br />

installed before the starter will operate.<br />

Two Speed Starters<br />

Two speed manual starters are<br />

designed for control of small single<br />

phase AC motors having separate<br />

windings for high and low speed<br />

operation. Two toggle operated starters<br />

are used, with overload protection<br />

included for each motor winding.<br />

Surface mounting devices, and those<br />

with a gray flush plate, utilize a<br />

mechanical interlock which allows<br />

direct control of the motor by means<br />

of the toggle operators.<br />

Enclosures<br />

Class SMF, NEMA Type 1 surface<br />

mounting enclosures are sheet steel<br />

with a thermo-plastic wrap-around cover<br />

for convenience in wiring. The NEMA<br />

Type 1 enclosure is also available in an<br />

oversized version which allows more<br />

wiring space. A zinc alloy die casting is<br />

used for NEMA Type 4 enclosures.<br />

Pilot Lights<br />

Red or green neon pilot light units<br />

are available for flush mounting plates,<br />

NEMA Type 1 enclosures, and NEMA<br />

Type 4 enclosures. Pilot lights may<br />

be either factory or field installed. (For<br />

starters that contain a pilot light, a Red<br />

light is standard. For a Green pilot light<br />

add ”G” to the end of the catalog<br />

number.)<br />

Terminals<br />

Binding head screw type terminals are<br />

suitable for #10 or smaller copper wire,<br />

and are accessible from the front. All<br />

terminals are clearly marked.<br />

Mounting<br />

Open types without a pilot light fit<br />

standard single gang switch boxes, and<br />

can be used with any cover plate having<br />

a standard toggle cutout. Single-unit<br />

flush mounting types, including those<br />

with pilot lights, are suitable for wall<br />

mounting in a standard switch box or<br />

for machine cavity mounting without<br />

a box.<br />

Operation<br />

Available with toggle handle or with<br />

removable key type operator to<br />

discourage unauthorized operation.<br />

Class SMF Starter in a NEMA Type 1<br />

Enclosure with Pilot Light<br />

Emergency Off Actuator<br />

A toggle operator extender is available<br />

for Class SMF, NEMA Type 1 surface<br />

mounted units. The extender has a red<br />

vinyl button that provides a fast and<br />

easy method for locating and switching<br />

the device‘s toggle operator into<br />

the OFF position. The Emergency Off<br />

Actuator is available in kit form only<br />

for field installation.<br />

Handle Guard/Lock-Off<br />

An optional handle guard on Class<br />

SMF, NEMA Type 1 enclosed starters<br />

prevents accidental operation of the<br />

toggle operator and also allows the<br />

toggle operator to be padlocked in<br />

either the “ON” or “OFF” position.<br />

This handle guard can be factory<br />

installed on NEMA Type 1 enclosed<br />

starters and is also available in kit form<br />

for field installation on NEMA Type 1<br />

surface and flush mounting enclosures.<br />

Standard NEMA Type 4 metallic<br />

enclosures include provisions for<br />

padlocking the device in the<br />

OFF position.<br />

17-6<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Manual Control<br />

Fractional HP Starters with Melting Alloy Overload, Class SMF<br />

Class SMF Starter in a NEMA Type 1<br />

Enclosure with Pilot Light<br />

Ordering Information<br />

Heater Elements see page 17-119.<br />

Field Modification Kits see page 17-100.<br />

Dimensions see page 17-126.<br />

Wiring Diagrams see page 17-155.<br />

Revised on 01/31/18<br />

Selection<br />

Horsepower Ratings<br />

Maximum Horsepower<br />

AC Single Phase DC<br />

Volts 1-Pole 2-Pole 2-Pole<br />

115 1 1 3<br />

⁄4<br />

230 1 2 3<br />

⁄4<br />

277 1 1 —<br />

Starter—Class SMF, Single Phase a<br />

General Purpose Flush Mounting NEMA Type 1 General Purpose NEMA Type NEMA NEMA Type<br />

Open Starter with Flush Plate Enclosure, Surface Mounting 3R, 4 & 12 Type 4 3R, 7 & 9<br />

(No Enclosure Provided) Watertight, Watertight, Div 1 and Div 2<br />

Dust-tight Dust-tight Class I Groups<br />

Metallic Metallic B, C, D &<br />

Standard Jumbo<br />

Enclosure Enclosure Class II Groups<br />

Gray Stainless Stainless<br />

with Clear Cover<br />

E, F, G<br />

Flush Steel Steel<br />

Enclosures<br />

Type Open Type Plate Flush Plate Flush Plate Standard Oversized<br />

of No. of Catalog List Catalog List Catalog List Catalog List Catalog List Catalog List Catalog List Catalog List Catalog List<br />

Operator Poles Starter Features e Number Price $ Number Price $ Number Price $ Number Price $ Number Price $ Number Price $ Number Price $ Number Price $ Number Price $<br />

Standard SMFF01 SMFFF1 SMFFS1 — — SMFFG1 SMFFGJ1 SMFFWN1 — — — —<br />

1<br />

Red Pilot Light SMFF01P SMFFF1P SMFFS1P SMFFSJ1P SMFFG1P SMFFGJ1P — — — —<br />

Toggle<br />

Standard SMFF02 SMFFF2 SMFFS2 — — SMFFG2 SMFFGJ2 SMFFWN2 — — — —<br />

2<br />

Red Pilot Light SMFF02P SMFFF2P SMFFS2P SMFFSJ2P SMFFG2P SMFFGJ2P — — — —<br />

Standard SMFF03 SMFFF3 SMFFS3 — — SMFFG3 SMFFGJ3 SMFFWN3 — — — —<br />

1<br />

Red Pilot Light SMFF03P SMFFF3P SMFFS3P SMFFSJ3P SMFFG3P SMFFGJ3P — — — —<br />

Key<br />

Standard SMFF04 — — SMFFS4 — — SMFFG4 SMFFGJ4 SMFFWN4 — — — —<br />

2<br />

Red Pilot Light SMFF04P SMFFF4P SMFFS4P SMFFSJ4P SMFFG4P SMFFGJ4P — — — —<br />

Starter With Handle Guard/Lock-Off—Class SMF, Single Phase a<br />

Standard — — d — d — d — SMFFG5 SMFFGJ5 — — SMFFW1 b SMFFR1 b<br />

Red Pilot Light — — d — d — d — SMFFG5P SMFFGJ5P — — SMFFW1P b — —<br />

1 (2) 3 ⁄4" NPT Outlets — — d — d — d — — — — — — — SMFFW1H SMFFR1H<br />

Toggle<br />

Red Pilot Light — — d — d — d — SMFFG6P SMFFGJ6P — — SMFFW2P b — —<br />

2 (2) 3 ⁄4" NPT Outlets — — d — d — d — — — — — — — SMFFW2H SMFFR2H<br />

(2) 3 ⁄4" NPT Outlets<br />

— — d — d — d — — — — — — — SMFFW2PH — —<br />

and Red Pilot Light<br />

One Starter in Duplex Enclosure—Class SMF, Single Phase a<br />

(2) 3 ⁄4" NPT Outlets<br />

and Red Pilot Light<br />

— — d — d — d — — — — — — — SMFFW1PH — —<br />

Standard — — d — d — d — SMFFG6 SMFFGJ6 — — SMFFW2 b SMFFR2 b<br />

General Purpose Flush Mounting<br />

Open Starter with Flush Plate - (No Enclosure Provided)<br />

Gray Flush Plate Stainless Steel Flush NEMA Type 1 General<br />

For Wall or Cavity Plate for Wall or Cavity Purpose Enclosure Replacement<br />

Type of Number Mounting Mounting Surface Mounting Starters<br />

Operator of Poles Starter Features e Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $<br />

Toggle 2<br />

Standard — — — — SMFFG02 — —<br />

Red Pilot Light — — — — SMFFG02P — —<br />

Key 2 Red Pilot Light — — — — SMFFG04P — —<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Two Starters In Duplex Enclosure—Class SMF, Single Phase c<br />

Standard SMFFF222 — — SMFFG222 — —<br />

Toggle 2 Per Starter<br />

Red Pilot Light on Each Starter SMFFF222P — — SMFFG222P — —<br />

Key 2 Per Starter Red Pilot Light on Each Starter SMFFF44P SMFFS44P SMFFG44P — —<br />

Starter And “Auto-Off-Hand” SPDT Selector Switch (AC Only)—Class SMF, Single Phase a<br />

Standard SMFFF71 — — SMFFG71 — —<br />

1<br />

Red Pilot Light SMFFF71P SMFFS71P SMFFG71P — —<br />

Toggle<br />

Standard — — — — SMFFG72 — —<br />

2<br />

Red Pilot Light SMFFF72P SMFFS72P SMFFG72P — —<br />

Key 2 Red Pilot Light SMFFF74P SMFFS74P SMFFG74P — —<br />

Two Speed Starters (AC Only)—Class SMF, Single Phase c<br />

Mechanical Interlock SMFFF11 — — SMFFG11 SMFF01T<br />

1 Mechanical Interlock and (2) Red Pilot Lights SMFFF11P — — SMFFG11P SMFF01PT<br />

Mechanical Interlock, HIGH-OFF-LOW<br />

— — — — — — SMFF01PT<br />

Selector Switch and (2) Red Pilot Lights<br />

Toggle<br />

Mechanical Interlock SMFFF22 — — SMFFG22 — —<br />

2 Mechanical Interlock and (2) Red Pilot Lights SMFFF22P — — SMFFG22P SMFF02PT<br />

Mechanical Interlock, HIGH-OFF-LOW<br />

— — SMFFS202P — — SMFF02PT<br />

Selector Switch and (2) Red Pilot Lights<br />

a One heater element required.<br />

b Furnished with (1) 3 ⁄4" NPT Outlet in bottom (reversible<br />

for top feed).<br />

c Two heater elements required.<br />

d Order Open Type starter plus separate handle guard kit.<br />

e For starters that contain a pilot light, a Red light is<br />

standard. For a Green pilot light add ”G” to the end of<br />

the catalog number.<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-7


Manual Control<br />

Fractional HP Switches, Class MMS, MRS<br />

General<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Class MMS, MRS<br />

Class MMS and MRS motor starting<br />

switches provide manual “ON-OFF”<br />

control of single or three phase AC<br />

motors where overload protection is<br />

not required or is provided separately.<br />

Compact construction and a 600 volt<br />

rating make these switches suitable<br />

for a wide range of industrial and<br />

commercial uses. Typical applications<br />

include small machine tools, pumps,<br />

fans, conveyors and many other types<br />

of electrical machinery. They can also<br />

be used on non-motor loads such as<br />

resistance heating applications.<br />

Continuous Current Rating<br />

MMS & MRS: 30 amperes at 250<br />

volts max, 26.4 amperes at 277 volts,<br />

20 amperes at 600 volts max, 30<br />

amperes resistive at 600 volts max.<br />

Two Speed—Class MRS<br />

Two speed manual switches may be<br />

used with separate winding three phase<br />

or single phase AC motors where<br />

overload protection is not required or is<br />

provided separately. Two switches are<br />

employed to give “ON-OFF” control in<br />

each speed.<br />

Reversing—Class MRS<br />

Reversing manual switches provide<br />

a compact means of starting, stopping<br />

and reversing AC motors where<br />

overload protection is not required or<br />

is provided separately. They are suitable<br />

for use with three phase squirrel cage<br />

motors and for single phase motors<br />

which can be reversed by reconnecting<br />

motor leads. Two switches are used,<br />

one to connect the motor forward<br />

rotation and one for reverse.<br />

Enclosures<br />

Class MMS, MRS, NEMA Type 1<br />

surface mounting enclosures are sheet<br />

steel with a thermo-plastic wrap-around<br />

cover for convenience in wiring.<br />

The NEMA Type 1 enclosure is also<br />

available in an oversized version which<br />

allows more wiring space. A zinc alloy<br />

die casting is used for NEMA Type 4<br />

enclosures.<br />

Pilot Lights<br />

Red or green neon pilot light units<br />

are available for flush mounting plates,<br />

NEMA Type 1 enclosures, and NEMA<br />

Type 4 enclosures. Pilot lights may<br />

be either factory or field installed. (For<br />

switches that contain a pilot light, a Red<br />

light is standard. For a Green pilot light<br />

add ”G” to the end of the catalog<br />

number.)<br />

Terminals<br />

Binding head screw type terminals are<br />

suitable for #10 or smaller copper wire,<br />

and are accessible from the front. All<br />

terminals are clearly marked.<br />

Mounting<br />

Open types without a pilot light fit<br />

standard single gang switch boxes, and<br />

can be used with any cover plate having<br />

a standard toggle cutout. Single-unit<br />

flush mounting types, including those<br />

with pilot lights, are suitable for wall<br />

mounting in a standard switch box or<br />

for machine cavity mounting without<br />

a box.<br />

Operation<br />

Available with toggle handle or with<br />

removable key type operator to<br />

discourage unauthorized operation.<br />

Class MMS Switch in a<br />

NEMA Type 1 Enclosure<br />

Emergency Off Actuator<br />

A toggle operator extender is available<br />

for Class MMS, MRS, NEMA Type 1<br />

surface mounted units. The extender<br />

has a red vinyl button that provides a<br />

fast and easy method for locating and<br />

switching the device‘s toggle operator<br />

into the OFF position. The Emergency<br />

Off Actuator is available in kit form<br />

only for field installation.<br />

Handle Guard/Lock-Off<br />

An optional handle guard on Class<br />

MMS, MRS, NEMA Type 1 enclosed<br />

switches prevents accidental operation<br />

of the toggle operator and also allows<br />

the toggle operator to be padlocked in<br />

either the “ON” or “OFF” position. This<br />

handle guard is available in kit form for<br />

field installation on NEMA Type 1<br />

surface and flush mounting enclosures.<br />

Standard NEMA Type 4 metallic<br />

enclosures include provisions for<br />

padlocking the device in the<br />

OFF position.<br />

17-8<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Manual Control<br />

Switches a , Class MMS, MRS<br />

Revised on 01/31/18<br />

Selection<br />

Class MMS Switch in a<br />

NEMA Type 1 Enclosure<br />

Ordering Information<br />

Heater Elements not Required.<br />

Field Modification Kits see<br />

page 17-100.<br />

Dimensions see page 17-126.<br />

Wiring Diagrams see page 17-155.<br />

Horsepower Ratings<br />

No of Motor Type<br />

Maximum HP<br />

DC Ratings<br />

Device Poles AC 115V 230V 450–575V 90V 115V 230V<br />

Class MMS<br />

2 Single Phase 2 2 3 1 2 1 1 /2<br />

3 3-Phase 2 7 1 /2 10 1 2 1 1 /2<br />

Class MRS 2 Single Phase 2 2 3 1 2 1 1 /2<br />

Reversing 3 3-Phase 2 7 1 /2 10 1 2 1 1 /2<br />

2 Single Phase 2 2 3 1 2 1<br />

Class MMS<br />

/2<br />

3 3-Phase, Constant or Variable Torque 2 7<br />

Two Speed<br />

/2 10 1 2 1 1 /2<br />

3 3-Phase, Constant Horsepower 2 7 1 /2 10 1 2 1 1 /2<br />

Switch—Class MMS, Single Phase and 3-Phase<br />

General Purpose Flush Mounting NEMA Type 1 General Purpose NEMA Type NEMA NEMA<br />

Open Switch with Flush Plate Enclosure Surface Mounting 3R, 4 & 12 Type 4 b Type 7 & 9 b<br />

(No Enclosure Provided) Watertight, Watertight, Class I Groups<br />

Standard Jumbo Dust-tight Dust-tight B, C & D &<br />

Gray Stainless Stainless Metallic Enclosurer Metallic Class II Groups<br />

with Clear Cover Enclosure E, F, G<br />

Flush Steel Steel<br />

Enclosures<br />

Type No Open Type Plate Flush Plate Flush Plate Standard Oversized<br />

of of Switch Catalog List Catalog List Catalog List Catalog List Catalog List Catalog List Catalog List Catalog List Catalog List<br />

Operator Poles Features d Number Price $ Number Price $ Number Price $ Number Price $ Number Price $ Number Price $ Number Price $ Number Price $ Number Price $<br />

2<br />

Standard MMSK01 MMSKF1 MMSKS1 — MMSKG1 — MMSKWN1 MMSKW1 MMSKR1<br />

Red Pilot Light<br />

115V AC MMSK01A c MMSKF1A MMSKS1A — MMSKG1A MMSKGJ1A MMSKW1A —<br />

Toggle<br />

Red Pilot Light<br />

230V AC<br />

MMSK01B c MMSKF1B MMSKS1B MMSKSJ1B MMSKG1B — MMSKW1B —<br />

3 Standard MMSK02 MMSKF2 MMSKS2 — MMSKG2 MMSKGJ2 MMSKWN2 MMSKW2 MMSKR2<br />

Red Pilot Light<br />

208-240V AC MMSK02B c MMSKF2B MMSKS2B — MMSKG2B MMSKGJ2B MMSKW2B —<br />

Red Pilot Light<br />

440-600V AC<br />

MMSK02C c — MMSKS2C MMSKSJ2C MMSKG2C MMSKGJ2C MMSKW2C —<br />

2<br />

Standard MMSK03 MMSKF3 MMSKS3 — MMSKG3 MMSKGJ3 MMSKWN3 — —<br />

Red Pilot Light<br />

115V AC — MMSKF3A MMSKS3A MMSKSJ3A MMSKG3A MMSKGJ3A — —<br />

Key<br />

Red Pilot Light<br />

230V AC<br />

MMSK03B MMSKF3B MMSKS3B MMSKSJ3B MMSKG3B MMSKGJ3B — —<br />

3<br />

Standard MMSK04 MMSKF4 MMSKS4 — MMSKG4 MMSKGJ4 MMSKWN4 — —<br />

Red Pilot Light<br />

208–240V AC MMSK04B MMSKF4B MMSKS4B MMSKSJ4B MMSKG4B MMSKGJ4B — —<br />

Red Pilot Light<br />

MMSK04C<br />

440–600V AC<br />

MMSKF4C MMSKS4C MMSKSJ4C MMSKG4C MMSKGJ4C — —<br />

Reversing Switch—Class MRS, Single Phase and 3-Phase<br />

General Purpose<br />

Flush Mounting NEMA Type 1<br />

Open Switch with Flush Plate General Purpose Replacement Switch<br />

Type of Number of Suitable Switch Features d (Including (No Enclosure Provided) Enclosure Surface Mounting Class MRS<br />

Operator Poles Motor Types Mechanical Interlock) Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $<br />

Single Phase Standard MRSKF11 — MRSK01T<br />

2 3-Lead Red Pilot Device—115V AC MRSKF11A — MRSK01AT<br />

Repulsion-Induction Red Pilot Device— 230V AC MRSKF11B MRSKG11B MRSK01BT<br />

Toggle<br />

3-Phase; Also<br />

Standard MRSKF22 MRSKG22 —<br />

Single Phase Capacitor, Red Pilot Light—110–120V AC MRSKF22A MRSKG22A MRSK02AT<br />

3<br />

Split Phase, or 4-Lead Red Pilot Light—208–220V AC MRSKF22B — MRSK02BT<br />

Repulsion-Induction<br />

Red Pilot Light—440–600V AC MRSKF22C MRSKG22C MRSK02CT<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Two Speed Switch—Class MMS, Single Phase and 3-Phase<br />

General Purpose<br />

Flush Mounting NEMA Type 1<br />

Open Switch with Flush Plate General Purpose Replacement Switch<br />

Type of Number of Suitable Switch Features d (Including (No Enclosure Provided) Enclosure Surface Mounting Class MRS<br />

Operator Poles Motor Types Mechanical Interlock) Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $<br />

Single Phase Standard MMSKF11 MMSKG11 MRSK01T<br />

2 Two Winding (2) Red Pilot Devices—115V AC MMSKF11A MMSKG11A MRSK01AT<br />

Toggle<br />

(3-Lead) (2) Red Pilot Devices—230V AC MMSKF11B MMSKG11B MRSK01BT<br />

3-Phase Standard MMSKF22 MMSKG22 MRSK02T<br />

3 Separate Winding (2) Red Pilot Lights—208–240V AC MMSKF22B MMSKG22B MRSK02BT<br />

(Wye-Connected) (2) Red Pilot Lights—440–600V AC MMSKF22C MMSKG22C MRSK02CT<br />

a Manual switches do not include overloads.<br />

b Furnished with (1) 3/4" NPT outlet in bottom (reversible<br />

for top feed). In order to obtain a 3 ⁄4" NPT outlet in top<br />

and bottom, add suffix letter “H” to type number with<br />

List Price adder.<br />

c Do not use as replacement interiors for NEMA Type 4<br />

metallic enclosures. For replacement unit, order<br />

Type MMSK01 or MMSK02 and separate pilot light kit.<br />

d For switches that contain a pilot light, a Red light is<br />

standard. For a Green pilot light add ”G” to the end<br />

of the catalog number.<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-9


Manual Control<br />

Starters and Switches, Class 11 - 3RV<br />

Revised on 03/31/20<br />

General<br />

Now Available with the New 3RV2 Innovations MSP<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Class 11 - 3RV<br />

Class 11 across the line manual<br />

starters and switches provide control<br />

for machinery where remote start stop<br />

control is not required.<br />

Class 11 - 3RV manual starters are<br />

used for single and poly-phase motors<br />

up to 20HP @ 575V. Starters have bimetallic<br />

heater elements to provide class<br />

10 overcurrent protection. Each starter<br />

has a fourth bimetallic strip that reacts<br />

only to the ambient temperature<br />

inside the control panel. This ambient<br />

compensation helps prevent the starter<br />

from nuisance tripping when the panel<br />

temperature is higher than the ambient<br />

temperature of the motor.<br />

A built-in differential trip bar causes the<br />

starter to trip faster on a phase loss<br />

condition to help reduce motor damage.<br />

Magnetic trip elements in each starter<br />

take the device off line when it senses<br />

current of 13 times the maximum FLA<br />

dial setting.<br />

Class 11 - 3RV switches provide<br />

control for inherently protected motors.<br />

Typical applications include metal and<br />

woodworking machinery, grinders,<br />

power saws, conveyors, fans, pumps,<br />

blowers, textile and packaging<br />

machinery, and paper cutters.<br />

Each switch is provided with magnetic<br />

trip elements which take the device off<br />

line when it senses current of 13 times<br />

the maximum switch rating.<br />

Class 11 - 3RV manual starters can be<br />

used as Type E self-protected manual<br />

combination starters (up to 22 amps)<br />

per UL508 or as components in<br />

Group Installation per NEC 430.53.<br />

When using the Class 11 - 3RV as a<br />

manual combination starter upstream<br />

protection is not required.<br />

Class 11 - 3RV controllers are available<br />

with low voltage protection which will<br />

automatically open the power poles<br />

when the voltage drops or the power<br />

is interrupted.<br />

Controllers with the LVP option provide<br />

the OSHA requirements for protecting<br />

personnel from potential injury caused<br />

by the automatic start-up of machinery<br />

following a voltage drop or power<br />

interruption when low voltage<br />

protection is specified.<br />

Class 11 - 3RV is available as Open<br />

style, or in NEMA 1.<br />

Standard Features include:<br />

b ON/OFF rotary handle with lockout<br />

and visible trip indication<br />

b Adjustment dial for setting to motor<br />

FLA (Starters only)<br />

b Low Voltage Protection (LVP) Option<br />

b Short Circuit trip at 13 times the<br />

maximum setting of the FLA dial<br />

or rated current<br />

b Ambient compensated up to 140°F<br />

b Phase loss sensitivity<br />

b Test trip function<br />

b LVP Option Meets OSHA<br />

Requirements<br />

b UL Listed<br />

b CSA Certified<br />

OPEN TYPE<br />

Starter<br />

NEMA 1<br />

General Purpose<br />

17-10<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Manual Control<br />

Starters and Switches, Class 11 - 3RV<br />

Revised on 03/31/20<br />

Selection<br />

Ordering Information<br />

No heaters required.<br />

Field Modification Kits see page 17-100.<br />

Dimensions see page 17-128.<br />

Wiring Diagrams see page 17-155.<br />

For applications requiring a low voltage<br />

protection coil see table at right.<br />

Low Voltage Protection Coil Table<br />

60 Hz Voltage Letter<br />

120V<br />

* F<br />

208V<br />

* D<br />

240V<br />

* G<br />

460V<br />

* H<br />

*Add corresponding letter to end of base Class 11<br />

catalog number for low voltage protection coil<br />

with List Price adder.<br />

Note: The LVP option for Open type 3RV is available<br />

from the factory, please order separately from<br />

the field modification kits on page 17-101.<br />

The coil voltage should correspond with the<br />

line voltage.<br />

Class 11 Manual Motor Starter<br />

Manual Starter—Class 11 - 3RV<br />

Max HP Enclosure<br />

FLA<br />

Adjustment Single Phase 3-Phase<br />

Range a HP Ratings<br />

HP Ratings<br />

Open Type<br />

NEMA 1<br />

General Purpose<br />

115V 230V 200V 230V 460V 575V Catalog No. List Price $. Catalog No. List Price $<br />

0.11-0.16 — — — — — — 3RV2011-0AA10 b 11AD3B<br />

0.14-0.2 — — — — — — 3RV2011-0BA10 b 11BD3B<br />

0.18-0.25 — — — — — — 3RV2011-0CA10 b 11CD3B<br />

0.22-0.32 — — — — — — 3RV2011-0DA10 b 11DD3B<br />

0.28-0.4 — — — — — — 3RV2011-0EA10 b 11ED3B<br />

0.35-0.5 — — — — — — 3RV2011-0FA10 b 11FD3B<br />

0.45-0.63 — — — — — — 3RV2021-0GA10 b 11GD3B<br />

0.55-0.8 — — — — — 1<br />

⁄2 3RV2021-0HA10 b 11HD3B<br />

0.7-1 — — — — 1<br />

⁄2<br />

1<br />

⁄2 3RV2021-0JA10 b 11JD3B<br />

0.9-1.25 — — — — 3<br />

⁄4<br />

3<br />

⁄4 3RV2021-0KA10 b 11KD3B<br />

1.1-1.6 — 1<br />

⁄10 — — 3<br />

⁄4 1 3RV2021-1AA10 b 11LD3B<br />

1.4-2 — 1<br />

⁄8 — — 1 1 1 ⁄2 3RV2021-1BA10 b 11MD3B<br />

1.8-2.5 — 1<br />

⁄6<br />

1<br />

⁄2<br />

1<br />

⁄2 1 1 ⁄2 1 1 ⁄2 3RV2021-1CA10 b 11ND3B<br />

2.2-3.2 1<br />

⁄10<br />

1<br />

⁄4<br />

3<br />

⁄4<br />

3<br />

⁄4 1 1 ⁄2 2 3RV2021-1DA10 b 11PD3B<br />

2.8-4 1<br />

⁄8<br />

1<br />

⁄3<br />

3<br />

⁄4 1 2 3 3RV2021-1EA10 b 11QD3B<br />

3.5-5 1<br />

⁄6<br />

1<br />

⁄2 1 1 3 3 3RV2021-1FA10 b 11RD3B<br />

4.5-6.3 1<br />

⁄4<br />

3<br />

⁄4 1 1 ⁄2 1 1 ⁄2 5 5 3RV2021-1GA10 b 11SD3B<br />

5.5-8 1<br />

⁄3 1 2 2 5 5 3RV2021-1HA10 b 11TD3B<br />

7-10 1<br />

⁄2 1 1 ⁄2 3 3 7 1 ⁄2 10 3RV2021-1JA10 b 11UD3B<br />

9-12.5 1<br />

⁄2 2 3 3 7 1 ⁄2 10 3RV2021-1KA10 b 11VD3B<br />

11-16 1 3 5 5 10 15 c 3RV2021-4AA10 b 11WD3B<br />

14-20 1 1 ⁄2 3 5 7 1 ⁄2 15 20 c 3RV2021-4BA10 b 11XD3B<br />

17-22 2 3 7 1 ⁄2 7 1 ⁄2 15 20 c 3RV2021-4CA10 b 11YD3B<br />

20-25 2 c 5 c 7 1 ⁄2 c 7 1 ⁄2 c 15 c 20 c 3RV2021-4DA10 b 11ZD3B<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Manual Switch—Class 11 - 3RV<br />

Rated<br />

Single Phase 3-Phase<br />

NEMA 1<br />

Current a HP Ratings<br />

HP Ratings<br />

Open Type<br />

General Purpose<br />

Max HP Enclosure<br />

115V 230V 200V 230V 460V 575V Catalog No. List Price $. Catalog No. List Price $<br />

1 — — — — 1 c ⁄2 1 c ⁄2 3RV2321-0JC10 b 111D3B<br />

5 1 c ⁄6 1 c ⁄2 1 c 1 c 3 c 3 c 3RV2321-1FC10 b 112D3B<br />

10 1 c ⁄2 1 1 c ⁄2 3 c 3 c 7 1 c ⁄2 10 c 3RV2321-1JC10 b 113D3B<br />

20 1 1 c ⁄2 3 c 5 c 7 1 c ⁄2 15 c 20 c 3RV2321-4BC10 b 114D3B<br />

25 2 c 5 c 7 1 c ⁄2 7 1 c ⁄2 15 c 20 c 3RV2321-4DC10 b 115D3B<br />

a Instantaneous Magnetic Trip will occur at 13 times<br />

the maximum FLA dial setting or rated switch current.<br />

b Product Category: IEC<br />

c Shaded Ratings apply for Manual Motor Controllers<br />

Only! These Ratings do not apply as UL Listed Manual<br />

Combination Starters.<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-11


Heavy Duty Control<br />

Catalog Numbering System<br />

Revised on 03/31/20<br />

General<br />

Class<br />

17 — Combination Starter<br />

(Non Fusible, Fusible)<br />

18 — Combination Starter<br />

(Circuit Breaker)<br />

25 — Reversing<br />

Combination Starter<br />

(Non Fusible, Fusible)<br />

26 — Reversing<br />

Combination Starter<br />

(Circuit Breaker)<br />

Size<br />

B — 00<br />

C — 0<br />

D — 1<br />

E — 1 3 ⁄4<br />

F — 2<br />

G — 2 1 ⁄2<br />

H — 3<br />

I — 3 1 ⁄2<br />

J — 4<br />

L — 5<br />

M — 6<br />

N — 7<br />

P — 8<br />

Model<br />

U — Solid-state OLR size<br />

0–4 & size 7 & 8<br />

P — Solid-state size 5 & 6<br />

Enclosure Size<br />

92 — Standard Width<br />

82 — Extra Wide<br />

Solid-state OLR<br />

Current Range<br />

Three Phase<br />

A — 0.25–1<br />

B — 0.75–3.4<br />

C — 3–12<br />

D — 5.5–22<br />

E — 10–40<br />

F — 13–52<br />

G — 25–100<br />

H — 50–200<br />

J — 100–300 w/ CT’s<br />

K — 133–400 w/ CT’s<br />

L — 200–600 w/ CT’s<br />

M — 250–750 w/ CT’s<br />

N — 400–1200 w/ CT’s<br />

Enclosure Type<br />

B — NEMA 1<br />

F — NEMA 4X Fiberglass<br />

N — NEMA 3/3R/4/12<br />

W — NEMA 4/4X 304 Stainless Steel<br />

X — NEMA 4/4X 316 Stainless Steel<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Class<br />

14 — Across the Line NEMA<br />

Motor Starter<br />

22 — Reversing NEMA Motor<br />

Starter<br />

40 — Across the Line NEMA<br />

Magnetic Contactor<br />

43 — Reversing NEMA Magnetic<br />

Contactor<br />

Size<br />

B — 00<br />

C — 0<br />

D — 1<br />

E — 1 3 ⁄4<br />

F — 2<br />

G — 2 1 ⁄2<br />

H — 3<br />

I — 3 1 ⁄2<br />

J — 4<br />

L — 5<br />

M — 6<br />

N — 7<br />

P — 8<br />

Model<br />

U — Solid-state OLR size<br />

00–4, Size 7 & 8<br />

P — Solid-state sizes 5 & 6<br />

Solid-state OLR<br />

Current Range<br />

Three Phase<br />

A — 0.25–1<br />

B — 0.75–3.4<br />

C — 3–12<br />

D — 5.5–22<br />

E — 10–40<br />

F — 13–52<br />

G — 25–100<br />

H — 50–200<br />

J — 100–300 w/ CT’s<br />

K — 133–400 w/ CT’s<br />

L — 200–600 w/ CT’s<br />

M — 250–750 w/ CT’s<br />

N — 400–1200 w/ CT’s<br />

Single Phase a<br />

A — 0.25–1<br />

B — 0.75–3.4<br />

C — 3–12<br />

D — 5.5–22<br />

Coil<br />

Pilot Control Circuit<br />

A — 110–120V/220–240V@60Hz<br />

2 — suitable for<br />

110V/190–220V@50Hz<br />

3-wire control<br />

C — 220–240V/440–480V@60Hz<br />

(NO aux.<br />

190–220V/380–440V@50Hz<br />

contact incl.)<br />

D — 200–208V@60Hz<br />

E — 550–600V@60Hz<br />

550V@50Hz<br />

Enclosure Size<br />

F — 120V@60Hz<br />

110V@50Hz<br />

1 — 2 power poles,1-phase G — 220–240V@60Hz<br />

3 — 3 power poles, 3-phase<br />

190–220V@50Hz<br />

8 — 3 power poles, 3-phase, H — 440–480V@60Hz<br />

extra wide enclosure<br />

380–440V@50Hz<br />

J — 24V@60Hz<br />

24V@50Hz<br />

L — 277V@60Hz<br />

240V@50Hz<br />

Enclosure Type<br />

A — Open<br />

B — NEMA 1<br />

F — NEMA 4X Fiberglass<br />

0 — NEMA 3/3R/4/12<br />

W — NEMA 4/4X 304 Stainless Steel<br />

X — NEMA 4/4X 316 Stainless Steel<br />

Class<br />

36 — Non<br />

Combination<br />

Reduced<br />

Voltage<br />

Starter<br />

37 — Combination<br />

Reduced<br />

Voltage<br />

Starter<br />

Size<br />

C — 0<br />

D — 1<br />

E — 1 3 ⁄4<br />

F — 2<br />

G — 2 1 ⁄2<br />

H — 3<br />

I — 3 1 ⁄2<br />

J — 4<br />

L — 5<br />

M — 6<br />

N — 7<br />

P — 8<br />

Model<br />

U — Solid-state<br />

OLR size 0–4<br />

& size 7 & 8<br />

P — Solid-state<br />

size 5 & 6<br />

Solid-state OLR<br />

Current Range<br />

Type<br />

T — Auto XFMR<br />

P — Part Wind.<br />

0 — Wye Delta<br />

Open Trans.<br />

C — Wye Delta<br />

Closed Trans.<br />

Line Volts<br />

2 — 230<br />

3 — 380<br />

4 — 460<br />

5 — 575<br />

6 — 200/208<br />

Enclosure Type<br />

A — Open<br />

B — NEMA 1<br />

W — NEMA 4/4X<br />

Coil<br />

D<br />

E<br />

F<br />

Disconnect Type <br />

D — Non Fused Disc.<br />

F — Fusible Disc.<br />

P — MCP<br />

Stainless Steel G<br />

0 — NEMA H<br />

3/3R/4/12 L<br />

a Single phase solid-state OLR available on Class 14<br />

Starters only.<br />

Not available on sizes 5–8.<br />

For Class 37 only.<br />

Not available on sizes 7 and 8.<br />

17-12<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Heavy Duty Starters<br />

Revised on 03/31/20<br />

Features and Benefits<br />

General<br />

Solid State Starter Class 14<br />

Standard Features<br />

Size 00–4 magnetic starters include the<br />

following standard features:<br />

b Rugged Industrial Design<br />

b Half Sizes for Cost and Space Savings<br />

b Dual Voltage, Dual Frequency Coils<br />

b Solid State Overload Protection<br />

b Wide Range of Accessories<br />

b Easy Coil Access<br />

b Overload Test Feature<br />

b Straight Thru Wiring<br />

b Gravity Dropout<br />

b Large Silver Cadmium Contacts<br />

b UL listed file #E14900 (class 14, 22,<br />

30, 40 & 43)<br />

b CSA certified file #LR 6535 (class 14,<br />

22, 30, 40 & 43)<br />

Application<br />

Heavy Duty starters are designed for<br />

across the line starting of single phase<br />

and polyphase motors.<br />

These controls are available in NEMA<br />

Sizes 00 through 8. In addition to the<br />

usual NEMA Starter Sizes, Siemens<br />

offers three exclusive Half Sizes; 1 3 ⁄4,<br />

2 1 ⁄2 and 3 1 ⁄2. These integral sizes offer<br />

the same rugged, industrial<br />

construction as our NEMA Sizes and<br />

ensure efficient operating performance.<br />

Half Sizes provide a real cost savings<br />

by cutting down on over capacity when<br />

NEMA Sizes exceed the motor ratings.<br />

All Siemens Heavy Duty controls,<br />

including our popular Half Sizes comply<br />

with applicable NEMA and UL tests.<br />

All starters are supplied with a NO<br />

holding interlock that in conjunction<br />

with an appropriate pilot device will<br />

provide low voltage protection or<br />

release.<br />

NEMA starters are ideal for<br />

applications requiring dependability<br />

and durability. Typical applications<br />

include use with machine tools, air<br />

conditioning equipment, material<br />

handling equipment, compressors,<br />

hoists and various production and<br />

industrial equipment as well as in<br />

demanding automotive applications.<br />

Starters are available as an open type<br />

or in NEMA 1, 12/3/3R, 4 (painted),<br />

4/4X (stainless), and 4X (fiberglass)<br />

enclosures.<br />

Gravity Dropout<br />

For added reliability, the gravity dropout<br />

of the armature and contacts is assisted<br />

by stainless steel springs which help<br />

provide quick, precise opening of the<br />

contacts.<br />

45 Degree, Wedge Action Contacts<br />

The 45 degree, wedge action contacts<br />

reduce tracking and provide faster arc<br />

quenching. The resulting self-cleaning<br />

and reduced contact bounce mean<br />

cooler operation and longer life for the<br />

large silver cadmium oxide contacts.<br />

Terminal Design<br />

Control terminals are self-rising<br />

pressure type.<br />

Molded Coil<br />

Magnetic coils are carefully wound and<br />

then sealed in epoxy. Encapsulation<br />

helps seal out moisture, promotes<br />

heat transfer and resists electrical,<br />

mechanical and thermal stresses.<br />

Dual Voltage/Frequency Coil<br />

Starters are available with dual voltage,<br />

dual frequency coils. They are designed<br />

to operate on either 50 or 60 Hertz.<br />

Molded Stationary Contact Block<br />

Thermoset materials resist arc tracking<br />

and the stresses of heat and severe<br />

impact.<br />

Field Modification Kits<br />

All starters can be modified in the field<br />

with a complete range of accessories.<br />

These include pushbuttons, selector<br />

switches, pilot lights, auxiliary contacts<br />

and surge suppressors.<br />

Auxiliary Equipment<br />

b NEMA starters are available with<br />

built-in START-STOP push buttons<br />

for 3-wire control or a<br />

HAND-OFF-AUTO selector<br />

switch for 2-wire control<br />

b Field modifications such as auxiliary<br />

contacts, pilot lights, push buttons,<br />

selector switches, and fuse blocks<br />

are available to meet particular<br />

application requirements<br />

b Normally opened or normally closed<br />

auxiliary power pole kits are available<br />

for Sizes 00 through 1 3 ⁄4<br />

b Transformers can be ordered as<br />

either factory or field modifications.<br />

In some cases these may require a<br />

larger enclosure<br />

b A full line of replacement parts are<br />

available including contact kits, coils,<br />

and overload relays<br />

Size 5 & 6 Starters<br />

Additional Features<br />

b Solid State Overload (3RB type)<br />

Standard<br />

b Latest technology in arc quenching to<br />

extend contactor life<br />

b Wide variety of enclosures in all<br />

starter configurations<br />

Size 7 & 8 Starters<br />

Additional Features<br />

b New Compact Design<br />

b Can be mounted in any position<br />

b Same coil voltage is AC or DC<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-13


Heavy Duty Starters<br />

Features and Benefits<br />

Selection<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

ESP200 Solid State Starter<br />

ESP200 starters combine the rugged<br />

NEMA contactors with a state of the<br />

art solid state overload that provides<br />

phase loss, phase unbalance ground<br />

fault protection. It offers the user<br />

greater motor protection and extended<br />

life in heavy duty applications. The<br />

ESP200 ultimately results in a cost<br />

savings to the user.<br />

ESP200 Solid State Overload Relays<br />

Standard features provide Improved<br />

Starter Performance:<br />

b True phase loss protection; trips<br />

within 3 seconds<br />

b Phase unbalanced prevents motor<br />

running inefficiently<br />

b Ground fault trip when selected<br />

b Selectable trip class 5, 10, 20 or 30<br />

b Reset trip can be selected Auto/<br />

Manual restart<br />

b Easy to select and use, Dip Switch<br />

selectable<br />

b Overload is self powered, no need for<br />

external power source<br />

Half Size Starters<br />

Half-Size starters feature all the<br />

rugged performance characteristics of<br />

our NEMA rated starter sizes, but are<br />

fractionally sized to more closely match<br />

your exact motor rating. As a result,<br />

significant economic savings are made<br />

possible without sacrificing the reliability<br />

you expect from a heavy duty starter.<br />

These additional starter sizes have the<br />

reserve capacity to handle occasional<br />

plugging and jogging applications<br />

without derating. Superior operating<br />

performance in heavy duty applications<br />

is assured by the large current carrying<br />

parts, not by derating the device.<br />

Exclusive “half-sizes” save potentially<br />

hundreds, even thousands of dollars<br />

per project.<br />

Using the table below, simply match<br />

the specific size starter to the<br />

horsepower rating of your motor.<br />

Every half-size starter saves you<br />

money—up to 31%.<br />

All “half-sizes” comply to applicable<br />

NEMA and UL standards.<br />

ESP200 ® FLA Adjustment Dial—Set the<br />

adjustment dial on the overload to the<br />

FLA of the motor.<br />

Figure 1<br />

Typical Solid-State Overload<br />

Adjustment Dial Markings<br />

DIP Switch Settings<br />

Adjust DIP switch settings to the Trip<br />

Class desired 5, 10, 20, or 30.<br />

b Set Phase Unbalance ON or OFF<br />

b Set Phase Loss ON or OFF<br />

b Set Reset to Manual or Automatic<br />

b Set Ground Fault ON or OFF<br />

Each overload is precisely calibrated<br />

and labels are laser printed.<br />

Savings for Siemens “Half-Size” Starters in NEMA 1 Enclosures, FVNR<br />

Motor Size<br />

“Half-Size”<br />

Starter Half<br />

Savings Over<br />

230V 460V Size<br />

Size List Price $ Next Full Size<br />

7 1 ⁄2 10 1 — —<br />

10 15 — 1 3 ⁄4 31%<br />

15 25 2 — —<br />

20 30 — 2 1 ⁄2 20%<br />

30 50 3 — —<br />

40 75 — 3 1 ⁄2 13%<br />

50 100 4 — —<br />

Standard Auxiliary Contacts<br />

Type Size (3rd Character) Configuration Internal / External<br />

B Thru E 1N.O. Internal<br />

All FVNR F Thru J 1N.O. External<br />

Starters &<br />

Contactors L Thru M 2N.O., 2N.C. External<br />

N Thru P 1N.O., 1N.C. External<br />

17-14<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Heavy Duty Motor Starters<br />

Solid State Overload with Auto/Manual Reset, Class 14<br />

Ordering Information<br />

Replace the (*) with a letter from the coil table. Dual voltage coils are<br />

wired on high voltage unless specified on order.<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see pages 17-129 open and 17-141 enclosed.<br />

Wiring Diagrams see page 17-156.<br />

Replacement Parts see page 17-120.<br />

Coil Table<br />

Revised on 03/31/20<br />

Selection<br />

60Hz Voltage<br />

Letter<br />

24 J<br />

120 F<br />

110–120/220–240 a A<br />

200–208 D<br />

220–240 G<br />

277 L<br />

220–240/440–480 a C<br />

440–480 H<br />

575–600 E<br />

For other voltages and frequencies,<br />

see Factory Modifications page 17-114.<br />

Open Type & Standard Width Enclosure, 3-Phase, 3-Pole<br />

Max Hp<br />

Overload<br />

Enclosure<br />

Open Type<br />

NEMA 1<br />

Standard Auxiliary<br />

General Purpose<br />

Contacts g<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

@ = W for 304 Stainless Steel<br />

@ = X for 316 Stainless Steel<br />

NEMA 4X Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

200<br />

NEMA Half<br />

Volts 230<br />

Volts 460<br />

Volts 575<br />

Amp Frame Catalog List Catalog List Catalog List Catalog List<br />

Volts Size Size Range Size Number Price $ Number Price $ Number Price $ Number Price $ Catalog List<br />

Number Price $<br />

1<br />

⁄6<br />

1<br />

⁄6<br />

1<br />

⁄3<br />

1<br />

⁄2 00 — 0.25–1 A 14BUA32A* 14BUA32B* Use Size 0 — Use Size 0 — Use Size 0 —<br />

1<br />

⁄2<br />

3<br />

⁄4 1 1 ⁄2 2 00 — 0.75–3.4 A 14BUB32A* 14BUB32B* Use Size 0 — Use Size 0 — Use Size 0 —<br />

1 1 ⁄2 1 1 ⁄2 2 — 00 — 3–12 A1 14BUC32A* 14BUC32B* Use Size 0 — Use Size 0 — Use Size 0 —<br />

1<br />

⁄6<br />

1<br />

⁄6<br />

1<br />

⁄3<br />

1<br />

⁄2 0 — 0.25–1 A 14CUA32A* 14CUA32B* 14CUA32@* 14CUA32F* 14CUA320*<br />

1<br />

⁄2<br />

3<br />

⁄4 1 1 ⁄2 2 0 — 0.75–3.4 A 14CUB32A* 14CUB32B* 14CUB32@* 14CUB32F* 14CUB320*<br />

2 2 5 5 0 — 3–12 A1 14CUC32A* 14CUC32B* 14CUC32@* 14CUC32F* 14CUC320*<br />

3 3 — — 0 — 5.5–22 A1 14CUD32A* 14CUD32B* 14CUD32@* 14CUD32F* 14CUD320*<br />

1<br />

⁄6<br />

1<br />

⁄6<br />

1<br />

⁄3<br />

1<br />

⁄2 1 — 0.25–1 A 14DUA32A* 14DUA32B* 14DUA32@* 14DUA32F* 14DUA320*<br />

1<br />

⁄2<br />

3<br />

⁄4 1 1 ⁄2 2 1 — 0.75–3.4 A 14DUB32A* 14DUB32B* 14DUB32@* 14DUB32F* 14DUB320*<br />

2 2 5 5 1 — 3–12 A1 14DUC32A* 14DUC32B* 14DUC32@* 14DUC32F* 14DUC320*<br />

3 3 10 10 1 — 5.5–22 A1 14DUD32A* 14DUD32B* 14DUD32@* 14DUD32F* 14DUD320*<br />

7 1 ⁄2 7 1 ⁄2 — — 1 — 10–40 A1 14DUE32A* 14DUE32B* 14DUE32@* 14DUE32F* 14DUE320*<br />

10 10 15 15 — 1 3 ⁄4 10–40 A1 14EUE32A* 14EUE32B* 14EUE32@* 14EUE32F* 14EUE320*<br />

10 15 25 25 2 — 13–52 B 14FUF32A* 14FUF32B* 14FUF32@* 14FUF32F* 14FUF320*<br />

15 20 30 30 — 2 1 ⁄2 25–100 B 14GUG32A* 14GUG32B* 14GUG32@* 14GUG32F* 14GUG320*<br />

25 30 50 50 3 — 25–100 B 14HUG32A* 14HUG32B* 14HUG32@* 14HUG32F* 14HUG320*<br />

30 40 75 75 — 3 1 ⁄2 50–200 B 14IUH32A* 14IUH32B* 14IUH32@* 14IUH32F* 14IUH320*<br />

40 50 100 100 4 — 50–200 B 14JUH32A* 14JUH32B* 14JUH32@* 14JUH32F* 14JUH320*<br />

75 100 200 200 5 — 55–250 — 14LPU32A* 14LPU32B* — — — — 14LPU320*<br />

150 200 400 400 6 — 160–630 — 14MPX32A* 14MPX32B* — — — — 14MPX320*<br />

— 300 600 600 7* — 400–1220 A1+CT 14NUN32A* 14NUN32B* — — — — 14NUN320*<br />

— 450 900 900 8 — 400–1220 A1+CT 14PUN32A* 14PUN32B* — — — — 14PUN320*<br />

Open Type & Standard Width Enclosure, Single Phase, 2-Pole <br />

Max Hp<br />

Overload<br />

Enclosure<br />

Open Type<br />

NEMA 1<br />

Standard Auxiliary<br />

General Purpose<br />

Contacts<br />

115<br />

Volts<br />

1<br />

⁄8<br />

208/<br />

230<br />

Volts<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

@ = W for 304 Stainless Steel<br />

@ = X for 316 Stainless Steel<br />

NEMA 4X Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

NEMA Amp Frame Catalog List Catalog List Catalog List Catalog List<br />

Size Range Size Number Price $ Number Price $ Number Price $ Number Price $ Catalog<br />

Number<br />

1<br />

⁄4 0 0.75–3.4 A 14CUB12A* 14CUB12B* 14CUB12@* 14CUB12F* 14CUB120*<br />

1<br />

⁄4<br />

1<br />

⁄2 0 3–12 A1 14CUC12A* 14CUC12B* 14CUC12@* 14CUC12F* 14CUC120*<br />

1 2 0 5.5–22 A1 14CUD12A* 14CUD12B* 14CUD12@* 14CUD12F* 14CUD120*<br />

1<br />

⁄8<br />

1<br />

⁄4 1 0.75–3.4 A 14DUB12A* 14DUB12B* 14DUB12@* 14DUB12F* 14DUB120*<br />

1<br />

⁄4<br />

1<br />

⁄2 1 3–12 A1 14DUC12A* 14DUC12B* 14DUC12@* 14DUC12F* 14DUC120*<br />

1 2 1 5.5–22 A1 14DUD12A* 14DUD12B* 14DUD12@* 14DUD12F* 14DUD120*<br />

3 7 1 ⁄2 2 25-100 B 14FUG12A* 14FUG12B* 14FUG12@* 14FUG12F* 14FUG120*<br />

7 1 ⁄2 15 3 25-100 B 14HUG12A* 14HUG12B* 14HUG12@* 14HUG12F* 14HUG120*<br />

List<br />

Price $<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Note: All starter sizes carry one maximum Hp rating (per the<br />

National Electric Code).<br />

a Dual voltage coils not available in size 5–8 starters.<br />

Coils D, F, or G will be wired for incoming voltage. J coil<br />

will be wired for separate source. Coils E, H, and L do<br />

not apply to single phase starters.<br />

F coil 100-250V AC 50/60Hz, or DC,<br />

H coil 150-500V AC 50/60Hz, or DC<br />

Only available F coil100-250V AC 50/60Hz, or DC<br />

To receive a single phase starter in an extra wide enclosure<br />

order an enclosure kit from pg 17-111 and the open style<br />

starter from pg 17-15 as separate items.<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-15


Heavy Duty Motor Starters<br />

Solid State Overload with Auto/Manual Reset, Class 14<br />

Revised on 03/31/20<br />

Selection<br />

Ordering Information<br />

Coil Table<br />

NEMA 1<br />

Replace the (*) with a letter from the coil table. Dual voltage coils are<br />

wired on high voltage unless specified on order.<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-141.<br />

Wiring Diagrams see page 17-156.<br />

Replacement Parts see page 17-120.<br />

60Hz Voltage<br />

Letter<br />

24 J<br />

120 F<br />

110–120/220–240 A<br />

200–208 D<br />

220–240 G<br />

277 L<br />

220–240/440–480 C<br />

440–480 H<br />

575–600 E<br />

For other voltages and frequencies,<br />

see Factory Modifications page 17-114.<br />

Extra Wide Enclosure, 3-Phase, 3-Pole<br />

Max Hp<br />

Overload<br />

Enclosure<br />

NEMA 1<br />

General Purpose<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

@ = W for 304 Stainless Steel<br />

@ = X for 316 Stainless Steel<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

NEMA & General<br />

Purpose Control<br />

200<br />

Volts<br />

230<br />

Volts<br />

460<br />

Volts<br />

575<br />

Volts<br />

NEMA<br />

Size<br />

Half<br />

Size<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

1<br />

⁄6<br />

1<br />

⁄6<br />

1<br />

⁄3<br />

1<br />

⁄2 00 — 0.25–1 A 14BUA82B* Use Size 0 — Use Size 0 —<br />

1<br />

⁄2<br />

3<br />

⁄4 1 1 ⁄2 2 00 — 0.75–3.4 A 14BUB82B* Use Size 0 — Use Size 0 —<br />

1 1 ⁄2 1 1 ⁄2 2 — 00 — 3–12 A1 14BUC82B* Use Size 0 — Use Size 0 —<br />

1<br />

⁄6<br />

1<br />

⁄6<br />

1<br />

⁄3<br />

1<br />

⁄2 0 — 0.25–1 A 14CUA82B* 14CUA82@* 14CUA820*<br />

1<br />

⁄2<br />

3<br />

⁄4 1 1 ⁄2 2 0 — 0.75–3.4 A 14CUB82B* 14CUB82@* 14CUB820*<br />

2 2 5 5 0 — 3–12 A1 14CUC82B* 14CUC82@* 14CUC820*<br />

3 3 — — 0 — 5.5–22 A1 14CUD82B* 14CUD82@* 14CUD820*<br />

1<br />

⁄6<br />

1<br />

⁄6<br />

1<br />

⁄3<br />

1<br />

⁄2 1 — 0.25–1 A 14DUA82B* 14DUA82@* 14DUA820*<br />

1<br />

⁄2<br />

3<br />

⁄4 1 1 ⁄2 2 1 — 0.75–3.4 A 14DUB82B* 14DUB82@* 14DUB820*<br />

17<br />

CONTROL<br />

PRODUCTS<br />

2 2 5 5 1 — 3–12 A1 14DUC82B* 14DUC82@* 14DUC820*<br />

3 3 10 10 1 — 5.5–22 A1 14DUD82B* 14DUD82@* 14DUD820*<br />

7 1 ⁄2 7 1 ⁄2 — — 1 — 10–40 A1 14DUE82B* 14DUE82@* 14DUE820*<br />

10 10 15 15 — 1 3 ⁄4 10–40 A1 14EUE82B* 14EUE82@* 14EUE820*<br />

10 15 25 25 2 — 13–52 B 14FUF82B* 14FUF82@* 14FUF820*<br />

15 20 30 30 — 2 1 ⁄2 25–100 B 14GUG82B* 14GUG82@* 14GUG820*<br />

25 30 50 50 3 — 25–100 B 14HUG82B* 14HUG82@* 14HUG820*<br />

30 40 75 75 — 3 1 ⁄2 50–200 B 14IUH82B* 14IUH82@* 14IUH820*<br />

Note: All starter sizes carry one maximum Hp rating (per the<br />

National Electric Code).<br />

17-16<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Combination Heavy Duty Starters<br />

Features and Benefits<br />

Revised on 03/31/20<br />

General<br />

Combination Starter<br />

Features<br />

Combination starters include<br />

the following features:<br />

b Manufactured with Cold Forming<br />

“TOX” Process<br />

b Solid State Overloads Standard on<br />

Sizes 5–8<br />

b Easy to Install<br />

b Wide Range of Enclosure Types<br />

Available<br />

b Heavy Duty Quarter Turns<br />

b 100kA Short Circuit Current Rating<br />

when Protected with Class R Fuses<br />

to 600V or MCP to 480V<br />

b Visible Blade Disconnect<br />

b Industrial Type Disconnect Handle<br />

b UL listed file #E185287 (class 17, 18,<br />

25, 26 & 32)<br />

b CSA certified file #LR 6535 (class 17,<br />

18, 25, 26 & 32)<br />

Application<br />

A combination starter meets National<br />

Electrical Code requirements for:<br />

1. A means of providing short circuit<br />

motor protection with fused or breaker<br />

disconnection of line voltage.<br />

2. A means of safeguarding personnel<br />

from contact with live parts and from<br />

accidental starting of machinery by<br />

disconnecting the motor and the<br />

controller.<br />

3. A motor controller with overload<br />

protection.<br />

Prewired combination starters eliminate<br />

the cost of wiring between separate<br />

disconnect and starter. Factory testing<br />

assures field performance. Combination<br />

starters also provide a more compact<br />

and attractive installation than separate<br />

units.<br />

Enclosure Types<br />

Combination starters are available in<br />

NEMA 1, 12/3/3R/4 (painted), 4/4X<br />

(stainless), and 4X fiberglass enclosures.<br />

Enclosures protect personnel from<br />

contact with live parts and depending<br />

upon the construction, protect the<br />

control in varying degrees from physical<br />

damage and harmful atmospheres. All<br />

enclosures are supplied with corrosion<br />

resistant finishes.<br />

Heavy Duty Disconnect Switches<br />

The disconnect switch that goes the<br />

distance in durability, performance and<br />

reliability has the following advantages:<br />

b Visible blades for the highest level<br />

of safety<br />

b Double break switching action to<br />

reduce arcing, increase lifetime and<br />

eliminate the “electric hinge”<br />

b More rugged positive action switch<br />

b Oversized lugs are standard<br />

b Line side shield to help guard<br />

personnel from contact with live parts<br />

b Higher horsepower rating for<br />

design E high efficiency motors<br />

b UL listed for IIsco, Burndy and T&B<br />

crimp type lugs<br />

b The 200A switch accepts up to 300<br />

MCM versus 250 MCM wire size<br />

Its rugged construction - with a high<br />

fault withstand rating of 100kA at 600<br />

VAC when fused with class R rated<br />

fuses - meets the most stringent<br />

industry standards set forth by the<br />

automotive, petro-chemical, and pulp<br />

and paper industries. UL recognized and<br />

CSA certified, our disconnect switches<br />

are available either non-fusible or fusible<br />

with class R and class J fuse clips.<br />

Enclosure Kits for NEMA<br />

Combination Starters Description<br />

You can assemble a non-stocked combination<br />

starter per your unanticipated<br />

needs in minutes. Say, for example,<br />

your customer needs a fusible combination<br />

starter that you don’t have in stock.<br />

You need in now, but don’t sweat it.<br />

Simply start with the enclosure kit<br />

which has the handle preinstalled. You<br />

install the required starter and fusible<br />

disconnect, connect the power wire<br />

and you are finished. Within minutes,<br />

you have the required combination<br />

starter in your hands. No more waiting<br />

on the factory. You need it, you got it!<br />

What Is In It For You!<br />

b Reduce Lead-time - What used to<br />

take days to get now takes minutes<br />

b Reduced Inventory - Instead of<br />

stocking scores of various combination<br />

starters, simply stock a few<br />

enclosure kits, disconnect kits, circuit<br />

breaker kits and open starters. With<br />

these basic “building blocks” you<br />

virtually have hundreds of products<br />

on-hand<br />

b Quality - The same high level of<br />

quality you have been accustomed<br />

to with our products will also be<br />

found in these new enclosure kits<br />

b UL Listed - By correctly following<br />

the instructions included with the kits,<br />

the product you build is<br />

UL/CSA Listed<br />

Refer to page 17-112 for more details.<br />

Siemens Type ETI Circuit Breaker<br />

The ETI circuit breaker is a device<br />

designed specifically for application<br />

in motor circuits. The ETI is a magnetic<br />

only protective device designed to<br />

provide protection against short<br />

circuit current.<br />

The instantaneous-only type ETI circuit<br />

breaker employs adjustable magnetic<br />

trip settings to allow broader application<br />

ranges and a higher degree of motor<br />

short circuit protection.<br />

Heavy Duty Starters<br />

These combination starters use the<br />

same starters described in the heavy<br />

duty starter section of this catalog.<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-17


Combination Heavy Duty Starters<br />

Non-Fusible with Solid State Overload, Class 17<br />

Ordering Information<br />

Replace the (*) with a letter from the coil table. Dual voltage coils are<br />

wired on high voltage unless specified on order.<br />

For Fusible Styles see page 17-20.<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-143.<br />

Wiring Diagrams see page 17-157.<br />

Replacement Parts see page 17-120.<br />

Revised on 03/31/20<br />

Coil Table<br />

Selection<br />

60Hz Voltage<br />

Letter<br />

24 J<br />

120 F<br />

110–120/220–240 a A<br />

200–208 D<br />

220–240 G<br />

277 L<br />

220–240/440–480 a C<br />

440–480 H<br />

575–600 E<br />

For other voltages and frequencies,<br />

see Factory Modifications page 17-114.<br />

Standard Width Enclosure, 3 Phase, 3-Pole<br />

Max Hp<br />

Overload<br />

Enclosure<br />

NEMA 1<br />

General Purpose<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

@ = W for 304 Stainless Steel<br />

@ = X for 316 Stainless Steel<br />

NEMA 4X Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Disc.<br />

200<br />

Volts<br />

230<br />

Volts<br />

460<br />

Volts<br />

575<br />

Volts<br />

NEMA<br />

Size<br />

Half<br />

Size<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

Amp<br />

Range<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

1<br />

⁄6<br />

1<br />

⁄6<br />

1<br />

⁄3<br />

1<br />

⁄2 0 — 0.25–1 A 30 17CUA92B* 17CUA92@* 17CUA92F* 17CUA92N*<br />

1<br />

⁄2<br />

3<br />

⁄4 1 1 ⁄2 2 0 — 0.75–3.4 A 30 17CUB92B* 17CUB92@* 17CUB92F* 17CUB92N*<br />

2 2 5 5 0 — 3–12 A1 30 17CUC92B* 17CUC92@* 17CUC92F* 17CUC92N*<br />

3 3 — — 0 — 5.5–22 A1 30 17CUD92B* 17CUD92@* 17CUD92F* 17CUD92N*<br />

1<br />

⁄6<br />

1<br />

⁄6<br />

1<br />

⁄3<br />

1<br />

⁄2 1 — 0.25–1 A 30 17DUA92B* 17DUA92@* 17DUA92F* 17DUA92N*<br />

1<br />

⁄2<br />

3<br />

⁄4 1 1 ⁄2 2 1 — 0.75–3.4 A 30 17DUB92B* 17DUB92@* 17DUB92F* 17DUB92N*<br />

2 2 5 5 1 — 3–12 A1 30 17DUC92B* 17DUC92@* 17DUC92F* 17DUC92N*<br />

3 3 10 10 1 — 5.5–22 A1 30 17DUD92B* 17DUD92@* 17DUD92F* 17DUD92N*<br />

7 1 ⁄2 7 1 ⁄2 — — 1 — 10–40 A1 60 17DUE92B* 17DUE92@* 17DUE92F* 17DUE92N*<br />

10 10 15 15 — 1 3 ⁄4 10–40 A1 60 17EUE92B* 17EUE92@* 17EUE92F* 17EUE92N*<br />

10 15 25 25 2 — 13–52 B 60 17FUF92B* 17FUF92@* 17FUF92F* 17FUF92N*<br />

15 20 30 30 — 2 1 ⁄2 25–100 B 100 17GUG92B* 17GUG92@* 17GUG92F* 17GUG92N*<br />

20 25 50 50 3 — 25–100 B 100 17HUG92B* 17HUG92@* 17HUG92F* 17HUG92N*<br />

30 40 75 75 — 3 1 ⁄2 50–200 B 200 17IUH92B* 17IUH92@* 17IUH92F* 17IUH92N*<br />

40 50 100 100 4 — 50–200 B 200 17JUH92B* 17JUH92@* 17JUH92F* 17JUH92N*<br />

75 100 200 200 5 — 55–250 — 400 17LPU92B* — — — — 17LPU92N*<br />

150 200 400 400 6 — 160–630 — 600 17MPX92B* — — — — 17MPX92N*<br />

— 300 600 600 7 — 400–1220 A1+CT 1200 17NUN92B* — — — — 17NUN92N*<br />

— 450 900 900 8 — 400–1220 A1+CT 1600 17PUN92B* — — — — 17PUN92N*<br />

List<br />

Price $<br />

Note: All starter sizes carry one maximum Hp rating (per the<br />

National Electric Code).<br />

a Dual voltage coils not available in starter sizes 5–8.<br />

For 60A disconnect, order fusible cat. no. page 17-20.<br />

For 20 HP and 200A disconnect, order fusible cat. no.<br />

page 17-20.<br />

For 25 HP and 200A disconnect, order fusible cat. no.<br />

page 17-20.<br />

For 600A disconnect, order fusible cat. no. page 17-20.<br />

F coil 100-250V AC 50/60Hz, or DC,<br />

H coil 150-500V AC 50/60Hz, or DC<br />

Only available<br />

F coil 100-250V AC 50/60Hz, or DC<br />

17-18<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Combination Heavy Duty Starters<br />

Non-Fusible with Solid State Overload, Class 17<br />

Revised on 03/31/20<br />

Selection<br />

Ordering Information<br />

Replace the (*) with a letter from the coil table. Dual voltage coils are<br />

wired on high voltage unless specified on order.<br />

For Fusible Styles see page 17-21.<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-143.<br />

Wiring Diagrams see page 17-157.<br />

Replacement Parts see page 17-120.<br />

Coil Table<br />

60Hz Voltage<br />

Letter<br />

24 J<br />

120 F<br />

110–120/220–240 A<br />

200–208 D<br />

220–240 G<br />

277 L<br />

220–240/440–480 C<br />

440–480 H<br />

575–600 E<br />

For other voltages and frequencies,<br />

see Factory Modifications page 17-114.<br />

Extra Wide Enclosure, 3-Phase, 3-Pole<br />

Hp<br />

200<br />

Volts<br />

230<br />

Volts<br />

460<br />

Volts<br />

575<br />

Volts<br />

NEMA<br />

Size<br />

Half<br />

Size<br />

Overload<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

Disc.<br />

Amp<br />

Range<br />

Enclosure<br />

NEMA 1<br />

General Purpose<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

@ = W for 304 Stainless Steel<br />

@ = X for 316 Stainless Steel<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

1<br />

⁄6<br />

1<br />

⁄6<br />

1<br />

⁄3<br />

1<br />

⁄2 0 — 0.25–1 A 30 17CUA82B* 17CUA82@* 17CUA82N*<br />

1<br />

⁄2<br />

3<br />

⁄4 1 1 ⁄2 2 0 — 0.75–3.4 A 30 17CUB82B* 17CUB82@* 17CUB82N*<br />

2 2 5 5 0 — 3–12 A1 30 17CUC82B* 17CUC82@* 17CUC82N*<br />

3 3 — — 0 — 5.5–22 A1 30 17CUD82B* 17CUD82@* 17CUD82N*<br />

1 1 1<br />

⁄6 ⁄6 ⁄3<br />

1<br />

⁄2<br />

1<br />

⁄2 1 — 0.25–1 A 30 17DUA82B* 17DUA82@* 17DUA82N*<br />

3<br />

⁄4 1 1 ⁄2 2 1 — 0.75–3.4 A 30 17DUB82B* 17DUB82@* 17DUB82N*<br />

2 2 5 5 1 — 3–12 A1 30 17DUC82B* 17DUC82@* 17DUC82N*<br />

3 3 10 10 1 — 5.5–22 A1 30 17DUD82B* 17DUD82@* 17DUD82N*<br />

7 1 ⁄2 7 1 ⁄2 — — 1 — 10–40 A1 60 17DUE82B* 17DUE82@* 17DUE82N*<br />

10 10 15 15 — 1 3 ⁄4 10–40 A1 60 17EUE82B* 17EUE82@* 17EUE82N*<br />

10 15 25 25 2 — 13–52 B 60 17FUF82B* 17FUF82@* 17FUF82N*<br />

15 20 30 30 — 2 1 ⁄2 25–100 B 100 a 17GUG82B* 17GUG82@* 17GUG82N*<br />

20 b 25 c 50 50 3 — 25–100 B 100 17HUG82B* 17HUG82@* 17HUG82N*<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Note: All starter sizes carry one maximum Hp rating (per the<br />

National Electric Code).<br />

For 60A disconnect, order fusible cat. no. page 17-21.<br />

For 20 HP and 200A disconnect, order fusible cat. no.<br />

page 17-21.<br />

For 25 HP and 200A disconnect, order fusible cat. no.<br />

page 17-21.<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-19


Combination Heavy Duty Starters<br />

Fusible with Solid State Overload, Class 17<br />

Ordering Information<br />

Replace the (*) with a letter from the coil table. Dual voltage coils are<br />

wired on high voltage unless specified on order.<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-143.<br />

Wiring Diagrams see page 17-157.<br />

Replacement Parts see page 17-120.<br />

Coil Table<br />

Revised on 03/31/20<br />

Selection<br />

60Hz Voltage<br />

Letter<br />

24 J<br />

120 F<br />

110–120/220–240 a A<br />

200–208 D<br />

220–240 G<br />

277 L<br />

220–240/440–480 a C<br />

440–480 H<br />

575–600 E<br />

For other voltages and frequencies,<br />

see Factory Modifications page 17-114.<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Standard Width Enclosure, 3-Phase, 3-Pole <br />

Max Hp<br />

200<br />

Volts<br />

1<br />

⁄6<br />

Overload<br />

Disc.<br />

Amp Fuse Clip<br />

Range Amp/Volts<br />

Enclosure<br />

NEMA 1<br />

General Purpose<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

@ = W for 304 Stainless Steel<br />

@ = X for 316 Stainless Steel<br />

NEMA 4X Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

230 460 575 NEMA Half Amp Frame<br />

Catalog List Catalog List Catalog List Catalog<br />

Volts Volts Volts Size Size Range Size<br />

Number Price $ Number Price $ Number Price $ Number<br />

1<br />

⁄6 — — 0 — 0.25–1 A 30 30A/250V 17CUA92B*10 17CUA92@*10 17CUA92F*10 17CUA92N*10<br />

— — 1<br />

⁄3<br />

1<br />

⁄2 0 — 0.25–1 A 30 30A/600V 17CUA92B*11 17CUA92@*11 17CUA92F*11 17CUA92N*11<br />

1<br />

⁄2<br />

3<br />

⁄4 — — 0 — 0.75–3.4 A 30 30A/250V 17CUB92B*10 17CUB92@*10 17CUB92F*10 17CUB92N*10<br />

— — 1 1 ⁄2 2 0 — 0.75–3.4 A 30 30A/600V 17CUB92B*11 17CUB92@*11 17CUB92F*11 17CUB92N*11<br />

2 2 — — 0 — 3–12 A1 30 30A/250V 17CUC92B*10 17CUC92@*10 17CUC92F*10 17CUC92N*10<br />

— — 5 5 0 — 3–12 A1 30 30A/600V 17CUC92B*11 17CUC92@*11 17CUC92F*11 17CUC92N*11<br />

3 3 — — 0 — 5.5–22 A1 30 30A/250V 17CUD92B*10 17CUD92@*10 17CUD92F*10 17CUD92N*10<br />

1<br />

⁄6<br />

1<br />

⁄6 — — 1 — 0.25–1 A 30 30A/250V 17DUA92B*10 17DUA92@*10 17DUA92F*10 17DUA92N*10<br />

— — 1<br />

⁄3<br />

1<br />

⁄2 1 — 0.25–1 A 30 30A/600V 17DUA92B*11 17DUA92@*11 17DUA92F*11 17DUA92N*11<br />

1<br />

⁄2<br />

3<br />

⁄4 — — 1 — 0.75–3.4 A 30 30A/250V 17DUB92B*10 17DUB92@*10 17DUB92F*10 17DUB92N*10<br />

— — 1 1 ⁄2 2 1 — 0.75–3.4 A 30 30A/600V 17DUB92B*11 17DUB92@*11 17DUB92F*11 17DUB92N*11<br />

2 2 — — 1 — 3–12 A1 30 30A/250V 17DUC92B*10 17DUC92@*10 17DUC92F*10 17DUC92N*10<br />

— — 5 5 1 — 3–12 A1 30 30A/600V 17DUC92B*11 17DUC92@*11 17DUC92F*11 17DUC92N*11<br />

3 3 — — 1 — 5.5–22 A1 30 30A/250V 17DUD92B*10 17DUD92@*10 17DUD92F*10 17DUD92N*10<br />

— — 10 10 1 — 5.5–22 A1 30 30A/600V 17DUD92B*11 17DUD92@*11 17DUD92F*11 17DUD92N*11<br />

7 1 ⁄2 7 1 ⁄2 — — 1 — 10–40 A1 30 30A/250V 17DUE92B*10 17DUE92@*10 17DUE92F*10 17DUE92N*10<br />

7 1 ⁄2 7 1 ⁄2 — — 1 — 10–40 A1 60 60A/250V 17DUE92B*12 17DUE92@*12 17DUE92F*12 17DUE92N*12<br />

— — 15 15 — 1 3 ⁄4 10–40 A1 60 60A/600V 17EUE92B*13 17EUE92@*13 17EUE92F*13 17EUE92N*13<br />

10 10 — — — 1 3 ⁄4 10–40 A1 60 60A/250V 17EUE92B*12 17EUE92@*12 17EUE92F*12 17EUE92N*12<br />

10 15 — — 2 — 13–52 B 60 60A/250V 17FUF92B*12 17FUF92@*12 17FUF92F*12 17FUF92N*12<br />

— — 25 25 2 — 13–52 B 60 60A/600V 17FUF92B*13 17FUF92@*13 17FUF92F*13 17FUF92N*13<br />

— — — 30 — 2 1 ⁄2 25–100 B 60 60A/600V 17GUG92B*13 17GUG92@*13 17GUG92F*13 17GUG92N*13<br />

— — 30 — — 2 1 ⁄2 25–100 B 100 100A/600V 17GUG92B*15 17GUG92@*15 17GUG92F*15 17GUG92N*15<br />

15 20 — — — 2 1 ⁄2 25–100 B 100 100A/250V 17GUG92B*14 17GUG92@*14 17GUG92F*14 17GUG92N*14<br />

20 25 — — 3 — 25–100 B 100 100A/250V 17HUG92B*14 17HUG92@*14 17HUG92F*14 17HUG92N*14<br />

— — 50 50 3 — 25–100 B 100 100A/600V 17HUG92B*15 17HUG92@*15 17HUG92F*15 17HUG92N*15<br />

25 30 — — 3 — 25–100 B 200 200A/250V 17HUG92B*16 17HUG92@*16 17HUG92F*16 17HUG92N*16<br />

30 40 — — — 3 1 ⁄2 50–200 B 200 200A/250V 17IUH92B*16 17IUH92@*16 17IUH92F*16 17IUH92N*16<br />

— — 75 75 — 3 1 ⁄2 50–200 B 200 200A/600V 17IUH92B*17 17IUH92@*17 17IUH92F*17 17IUH92N*17<br />

40 50 — — 4 — 50–200 B 200 200A/250V 17JUH92B*16 17JUH92@*16 17JUH92F*16 17JUH92N*16<br />

— — 100 100 4 — 50–200 B 200 200A/600V 17JUH92B*17 17JUH92@*17 17JUH92F*17 17JUH92N*17<br />

75 100 — — 5 — 55–250 — 400 400A/250V 17LPU92B*18 — — — — 17LPU92N*18<br />

— 100 — — 5 — 55–250 — 600 600A/250V 17LPU92B*20 — — — — 17LPU92N*20<br />

— — — 125 5 — 55–250 — 200 200A/600V 17LPU92B*17 — — — — 17LPU92N*17<br />

— — 200 200 5 — 55–250 — 400 400A/600V 17LPU92B*19 — — — — 17LPU92N*19<br />

— — 200 — 5 — 55–250 — 600 600A/600V 17LPU92B*21 — — — — 17LPU92N*21<br />

150 200 — — 6 — 160–630 — 600 600A/250V 17MPX92B*20 — — — — 17MPX92N*20<br />

— — 400 400 6 — 160–630 — 600 600A/600V 17MPX92B*21 — — — — 17MPX92N*21<br />

— — 400 400 6 — 160–630 — 800 800A/600V 17MPX92B*23 — — — — 17MPX92N*23<br />

— — 600 600 7 — 400–1220 A1+CT 1200 1200A/600V 17NUN92B*24 — — — — 17NUN92N*24<br />

— — 900 900 8 — 400–1220 A1+CT 1600 1600A/600V 17PUN92B*25 — — — — 17PUN92N*25<br />

List<br />

Price $<br />

Note: All starter sizes carry one maximum Hp rating (per the<br />

National Electric Code).<br />

a Dual voltage coils not available in starter sizes 5–8.<br />

Use Class J fuses only.<br />

Single phase wiring page 17-156.<br />

F coil 100-250V AC 50/60Hz, or DC,<br />

H coil 150-500V AC 50/60Hz, or DC<br />

Only available<br />

F coil 100-250V AC 50/60Hz, or DC<br />

17-20<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Combination Heavy Duty Starters<br />

Fusible with Solid State Overload, Class 17<br />

Ordering Information<br />

Replace the (*) with a letter from the coil table. Dual voltage coils are<br />

wired on high voltage unless specified on order.<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-143.<br />

Wiring Diagrams see page 17-157.<br />

Replacement Parts see page 17-120.<br />

Revised on 03/31/20<br />

Coil Table<br />

Selection<br />

60Hz Voltage<br />

Letter<br />

24 J<br />

120 F<br />

110–120/220–240 A<br />

200–208 D<br />

220–240 G<br />

277 L<br />

220–240/440–480 C<br />

440–480 H<br />

575–600 E<br />

For other voltages and frequencies,<br />

see Factory Modifications page 17-114.<br />

Extra Wide Enclosure, 3-Phase, 3-Pole<br />

Max Hp<br />

200<br />

Volts<br />

230<br />

Volts<br />

460<br />

Volts<br />

575<br />

Volts<br />

NEMA<br />

Size<br />

Half<br />

Size<br />

Overload<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

Disc.<br />

Amp<br />

Range<br />

Fuse Clip<br />

Amp/Volts<br />

Enclosure<br />

NEMA 1<br />

General Purpose<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight,<br />

@ = W for 304 Stainless Steel<br />

@ = X for 316 Stainless Steel<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

Catalog<br />

Number<br />

1<br />

⁄6<br />

1<br />

⁄6<br />

— — 0 — 0.25–1 A 30 30A/250V 17CUA82B*10 17CUA82@*10 17CUA82N*10<br />

— —<br />

1<br />

⁄3<br />

1<br />

⁄2 0 — 0.25–1 A 30 30A/600V 17CUA82B*11 17CUA82@*11 17CUA82N*11<br />

1<br />

⁄2<br />

3<br />

⁄4<br />

— — 0 — 0.75–3.4 A 30 30A/250V 17CUB82B*10 17CUB82@*10 17CUB82N*10<br />

— — 1 1 ⁄2 2 0 — 0.75–3.4 A 30 30A/600V 17CUB82B*11 17CUB82@*11 17CUB82N*11<br />

2 2 — — 0 — 3–12 A1 30 30A/250V 17CUC82B*10 17CUC82@*10 17CUC82N*10<br />

— — 5 5 0 — 3–12 A1 30 30A/600V 17CUC82B*11 17CUC82@*11 17CUC82N*11<br />

3 3 — — 0 — 5.5–22 A1 30 30A/250V 17CUD82B*10 17CUD82@*10 17CUD82N*10<br />

1<br />

⁄6<br />

1<br />

⁄6<br />

— — 1 — 0.25–1 A 30 30A/250V 17DUA82B*10 17DUA82@*10 17DUA82N*10<br />

— —<br />

1<br />

⁄3<br />

1<br />

⁄2<br />

1 — 0.25–1 A 30 30A/600V 17DUA82B*11 17DUA82@*11 17DUA82N*11<br />

1<br />

⁄2<br />

3<br />

⁄4<br />

— — 1 — 0.75–3.4 A 30 30A/250V 17DUB82B*10 17DUB82@*10 17DUB82N*10<br />

— — 1 1 ⁄2 2 1 — 0.75–3.4 A 30 30A/600V 17DUB82B*11 17DUB82@*11 17DUB82N*11<br />

2 2 — — 1 — 3–12 A1 30 30A/250V 17DUC82B*10 17DUC82@*10 17DUC82N*10<br />

— — 5 5 1 — 3–12 A1 30 30A/600V 17DUC82B*11 17DUC82@*11 17DUC82N*11<br />

3 3 — — 1 — 5.5–22 A1 30 30A/250V 17DUD82B*10 17DUD82@*10 17DUD82N*10<br />

— — 10 10 1 — 5.5–22 A1 30 30A/600V 17DUD82B*11 17DUD82@*11 17DUD82N*11<br />

5 5 — — 1 — 10–40 A1 30 30A/250V 17DUE82B*10 17DUE82@*10 17DUE82N*10<br />

7 1 ⁄2 7 1 ⁄2<br />

— — 1 — 10–40 A1 60 60A/250V 17DUE82B*12 17DUE82@*12 17DUE82N*12<br />

— — 15 15 — 1 3 ⁄4 10–40 A1 60 60A/600V 17EUE82B*13 17EUE82@*13 17EUE82N*13<br />

10 10 — — — 1 3 ⁄4 10–40 A1 60 60A/250V 17EUE82B*12 17EUE82@*12 17EUE82N*12<br />

10 15 — — 2 — 13–52 B 60 60A/250V 17FUF82B*12 17FUF82@*12 17FUF82N*12<br />

— — 25 25 2 — 13–52 B 60 60A/600V 17FUF82B*13 17FUF82@*13 17FUF82N*13<br />

— — — 30 — 2 1 ⁄2 25–100 B 60 60A/600V 17GUG82B*13 17GUG82@*13 17GUG82N*13<br />

— — 30 — — 2 1 ⁄2 25–100 B 100 100A/600V 17GUG82B*15 17GUG82@*15 17GUG82N*15<br />

15 20 — — — 2 1 ⁄2 25–100 B 100 100A/250V 17GUG82B*14 17GUG82@*14 17GUG82N*14<br />

20 25 — — 3 — 25–100 B 100 100A/250V 17HUG82B*14 17HUG82@*14 17HUG82N*14<br />

— — 50 50 3 — 25–100 B 100 100A/600V 17HUG82B*15 17HUG82@*15 17HUG82N*15<br />

25 30 — — 3 — 25–100 B 200 200A/250V 17HUG82B*16 17HUG82@*16 17HUG82N*16<br />

List<br />

Price $<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-21


Combination Heavy Duty Starters<br />

MCP Type with Solid State Overload, Class 18<br />

Ordering Information<br />

Replace the (*) with a letter from the coil table. Dual voltage coils are<br />

wired on high voltage unless specified on order.<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-143.<br />

Wiring Diagrams see page 17-157.<br />

Replacement Parts see page 17-120.<br />

Revised on 03/31/20<br />

Coil Table<br />

Selection<br />

60Hz Voltage<br />

Letter<br />

24 J<br />

120 F<br />

110–120/220–240 a A<br />

200–208 D<br />

220–240 G<br />

277 L<br />

220–240/440–480 a C<br />

440–480 H<br />

575–600 E<br />

For other voltages and frequencies,<br />

see Factory Modifications page 17-114.<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Standard Width Enclosure, 3-Phase, 3-Pole<br />

Max Hp<br />

200<br />

Volts<br />

230<br />

Volts<br />

460<br />

Volts<br />

575<br />

Volts<br />

NEMA<br />

Size<br />

Half<br />

Size<br />

Motor<br />

Circuit<br />

Interruter<br />

ETI Amps<br />

Overload<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

Enclosure<br />

NEMA 1<br />

General Purpose<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

@ = W for 304 Stainless Steel<br />

@ = X for 316 Stainless Steel<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

NEMA 4X Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

Catalog<br />

Number<br />

1<br />

⁄2<br />

1<br />

⁄2 1 1 0 — 3 0.75–3.4 A 18CUB92B* 18CUB92@* 18CUB92F* 18CUB92N*<br />

2 2 5 5 0 — 10 3–12 A1 18CUC92B* 18CUC92@* 18CUC92F* 18CUC92N*<br />

3 3 — — 0 — 25 5.5–22 A1 18CUD92B* 18CUD92@* 18CUD92F* 18CUD92N*<br />

1<br />

⁄2<br />

1<br />

⁄2 1 1 1 — 3 0.75–3.4 A 18DUB92B* 18DUB92@* 18DUB92F* 18DUB92N*<br />

2 2 5 5 1 — 10 3–12 A1 18DUC92B* 18DUC92@* 18DUC92F* 18DUC92N*<br />

3 3 7 1 ⁄2 10 1 — 25 5.5–22 A1 18DUD92B* 18DUD92@* 18DUD92F* 18DUD92N*<br />

7 1 ⁄2 7 1 ⁄2 10 — 1 — 30 10–40 A1 18DUE92B* 18DUE92@* 18DUE92F* 18DUE92N*<br />

— — 15 15 — 1 3 ⁄4 40 10–40 A1 18EUE92B* 18EUE92@* 18EUE92F* 18EUE92N*<br />

10 15 25 25 2 — 50 13–52 B 18FUF92B* 18FUF92@* 18FUF92F* 18FUF92N*<br />

15 20 30 30 — 2 1 ⁄2 100 25–100 B 18GUG92B* 18GUG92@* 18GUG92F* 18GUG92N*<br />

25 30 50 50 3 — 125 25–100 B 18HUG92B* 18HUG92@* 18HUG92F* 18HUG92N*<br />

30 40 75 75 — 3 1 ⁄2 125 50–200 B 18IUH92B* 18IUH92@* 18IUH92F* 18IUH92N*<br />

40 50 100 100 4 — 150 50–200 B 18JUH92B* 18JUH92@* 18JUH92F* 18JUH92N*<br />

50 75 150 200 5 — 250 55–250 — 18LPT92B* — — — — 18LPT92N*<br />

75 100 200 — 5 — 400 55–250 — 18LPU92B* — — — — 18LPU92N*<br />

100 125 250 300 6 — 400 160–630 — 18MPW92B* — — — — 18MPW92N*<br />

150 200 400 400 6 — 600 160–630 — 18MPX92B* — — — — 18MPX92N*<br />

— 250 500 500 7 — 800 400–1220 A1+CT 18NUV92B* — — — — 18NUV92N*<br />

— 300 600 600 7 — 1000 400–1220 A1+CT 18NUY92B* — — — — 18NUY92N*<br />

— 400 800 800 8 — 1200 400–1220 A1+CT 18PUW92B* — — — — 18PUW92N*<br />

— 450 900 900 8 — 1600 400–1220 A1+CT 18PUZ92B* — — — — 18PUZ92N*<br />

List<br />

Price $<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

a Dual voltage coils not available in starter sizes 5–8.<br />

F coil 100-250V AC 50/60Hz, or DC,<br />

H coil 150-500V AC 50/60Hz, or DC<br />

Only available<br />

F coil 100-250V AC 50/60Hz, or DC<br />

17-22<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Combination Heavy Duty Starters<br />

MCP Type with Solid State Overload, Class 18<br />

Revised on 03/31/20<br />

Selection<br />

Ordering Information<br />

Replace the (*) with a letter from the coil table. Dual voltage coils are<br />

wired on high voltage unless specified on order.<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-143.<br />

Wiring Diagrams see page 17-157.<br />

Replacement Parts see page 17-120.<br />

Coil Table<br />

60Hz Voltage<br />

Letter<br />

24 J<br />

120 F<br />

110–120/220–240 A<br />

200–208 D<br />

220–240 G<br />

277 L<br />

220–240/440–480 C<br />

440–480 H<br />

575–600 E<br />

For other voltages and frequencies,<br />

see Factory Modifications page 17-114.<br />

Extra Wide Enclosure, 3-Phase, 3-Pole<br />

Max Hp<br />

200<br />

Volts<br />

1<br />

⁄2<br />

230<br />

Volts<br />

460<br />

Volts<br />

575<br />

Volts<br />

NEMA<br />

Size<br />

Half<br />

Size<br />

Motor<br />

Circuit<br />

Interruter<br />

ETI Amps<br />

Overload<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

Enclosure<br />

NEMA 1<br />

General Purpose<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

@ = W for 304 Stainless Steel<br />

@ = X for 316 Stainless Steel<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

Catalog<br />

Number<br />

1<br />

⁄2 1 1 0 — 3 0.75–3.4 A 18CUB82B* 18CUB82@* 18CUB82N*<br />

List<br />

Price $<br />

2 2 5 5 0 — 10 3–12 A1 18CUC82B* 18CUC82@* 18CUC82N*<br />

3 3 — — 0 — 25 5.5–22 A1 18CUD82B* 18CUD82@* 18CUD82N*<br />

1<br />

⁄2<br />

1<br />

⁄2 1 1 1 — 3 0.75–3.4 A 18DUB82B* 18DUB82@* 18DUB82N*<br />

2 2 5 5 1 — 10 3–12 A1 18DUC82B* 18DUC82@* 18DUC82N*<br />

3 3 7 1 ⁄2 10 1 — 25 5.5–22 A1 18DUD82B* 18DUD82@* 18DUD82N*<br />

7 1 ⁄2 7 1 ⁄2 10 — 1 — 30 10–40 A1 18DUE82B* 18DUE82@* 18DUE82N*<br />

— — 15 15 — 1 3 ⁄4 40 10–40 A1 18EUE82B* 18EUE82@* 18EUE82N*<br />

10 15 25 25 2 — 50 13–52 B 18FUF82B* 18FUF82@* 18FUF82N*<br />

15 20 30 30 — 2 1 ⁄2 100 25–100 B 18GUG82B* 18GUG82@* 18GUG82N*<br />

25 30 50 50 3 — 125 25–100 B 18HUG82B* 18HUG82@* 18HUG82N*<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-23


Reversing Heavy Duty Starters<br />

Solid State Overload, Class 22<br />

Revised on 03/31/20<br />

Selection<br />

Ordering Information<br />

Replace the (*) with a letter from the coil table. Dual voltage coils are<br />

wired on high voltage unless specified on order.<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-130 open and 17-145 enclosed.<br />

Wiring Diagrams see page 17-158.<br />

Coil Table<br />

60Hz Voltage<br />

Letter<br />

24 J<br />

120 F<br />

110–120/220–240 a A<br />

200–208 D<br />

220–240 G<br />

277 L<br />

220–240/440–480 a C<br />

440–480 H<br />

575–600 E<br />

For other voltages and frequencies,<br />

see Factory Modifications page 17-114.<br />

Open Type & Standard Width Enclosure, 3-Phase, 3-Pole<br />

Max Hp<br />

Overload<br />

Enclosure<br />

Open Type<br />

NEMA 1<br />

Standard Auxiliary<br />

General Purpose<br />

Contacts <br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

304 Stainless Steel<br />

NEMA 4X Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

200<br />

Volts<br />

1<br />

⁄6<br />

230<br />

Volts<br />

1<br />

⁄6<br />

460<br />

Volts<br />

1<br />

⁄3<br />

575<br />

Volts<br />

NEMA<br />

Size<br />

Half<br />

Size<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

1<br />

⁄2 00 — 0.25–1 A 22BUA32A* 22BUA32B* Use Size 0 — Use Size 0 — Use Size 0 —<br />

List<br />

Price $<br />

NEMA & General<br />

Purpose Control<br />

1<br />

⁄2<br />

3<br />

⁄4 1 1 ⁄2 2 00 — 0.75–3.4 A 22BUB32A* 22BUB32B* Use Size 0 — Use Size 0 — Use Size 0 —<br />

1 1 ⁄2 1 1 ⁄2 2 — 00 — 3–12 A1 22BUC32A* 22BUC32B* Use Size 0 — Use Size 0 — Use Size 0 —<br />

1 1<br />

⁄6 ⁄6<br />

1<br />

⁄2<br />

1<br />

⁄3 1⁄2 0 — 0.25–1 A 22CUA32A* 22CUA32B* 22CUA32W* 22CUA32F* 22CUA320*<br />

3<br />

⁄4 1 1 ⁄2 2 0 — 0.75–3.4 A 22CUB32A* 22CUB32B* 22CUB32W* 22CUB32F* 22CUB320*<br />

2 2 5 5 0 — 3–12 A1 22CUC32A* 22CUC32B* 22CUC32W* 22CUC32F* 22CUC320*<br />

3 3 — — 0 — 5.5–22 A1 22CUD32A* 22CUD32B* 22CUD32W* 22CUD32F* 22CUD320*<br />

1 1 1<br />

⁄6 ⁄6 ⁄3<br />

1<br />

⁄2 1 — 0.25–1 A 22DUA32A* 22DUA32B* 22DUA32W* 22DUA32F* 22DUA320*<br />

1<br />

⁄2<br />

3<br />

⁄4 1 1 ⁄2 2 1 — 0.75–3.4 A 22DUB32A* 22DUB32B* 22DUB32W* 22DUB32F* 22DUB320*<br />

17<br />

CONTROL<br />

PRODUCTS<br />

2 2 5 5 1 — 3–12 A1 22DUC32A* 22DUC32B* 22DUC32W* 22DUC32F* 22DUC320*<br />

3 3 10 10 1 — 5.5–22 A1 22DUD32A* 22DUD32B* 22DUD32W* 22DUD32F* 22DUD320*<br />

7 1 ⁄2 7 1 ⁄2 — — 1 — 10–40 A1 22DUE32A* 22DUE32B* 22DUE32W* 22DUE32F* 22DUE320*<br />

10 10 15 15 — 1 3 ⁄4 10–40 A1 22EUE32A* 22EUE32B* 22EUE32W* 22EUE32F* 22EUE320*<br />

10 15 25 25 2 — 13–52 B 22FUF32A* 22FUF32B* 22FUF32W* 22FUF32F* 22FUF320*<br />

15 20 30 30 — 2 1 ⁄2 25–100 B 22GUG32A* 22GUG32B* 22GUG32W* 22GUG32F* 22GUG320*<br />

25 30 50 50 3 — 25–100 B 22HUG32A* 22HUG32B* 22HUG32W* 22HUG32F* 22HUG320*<br />

30 40 75 75 — 3 1 ⁄2 50–200 B 22IUH32A* 22IUH32B* 22IUH32W* 22IUH32F* 22IUH320*<br />

40 50 100 100 4 — 50–200 B 22JUH32A* 22JUH32B* 22JUH32W* 22JUH32F* 22JUH320*<br />

75 100 200 200 5 — 55–250 — 22LPU32A* 22LPU32B* — — — — 22LPU320*<br />

150 200 400 400 6 — 160–630 — 22MPX32A* 22MPX32B* — — — — 22MPX320*<br />

— 300 600 600 7 — 400–1220 A1+CT 22NUN32A* 22NUN32B* — — — — 22NUN320*<br />

— 450 900 900 8 — 400–1220 A1+CT 22PUN32A* 22PUN32B* — — — — 22PUN320*<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

a Dual voltage coils not available in size 5–8 starters.<br />

Only available<br />

F coil 100-250V AC 50/60Hz, or DC<br />

H coil 150-500V AC 50/60Hz, or DC<br />

Only available<br />

F coil 100-250V AC 50/60Hz, or DC<br />

Auxiliary contacts<br />

22B-22E 4th pole built-in<br />

22F-22J 2 NO & 2 NC<br />

17-24<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Combination Reversing Heavy Duty Starters<br />

Non-Fusible, Class 25<br />

Ordering Information<br />

Replace the (*) with a letter from the coil table. Dual voltage coils are<br />

wired on high voltage unless specified on order.<br />

Fuse clips see page 17-115.<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-147.<br />

Wiring Diagrams see page 17-159.<br />

Replacement Parts see page 17-120.<br />

Revised on 03/31/20<br />

Coil Table<br />

Selection<br />

60Hz Voltage<br />

Letter<br />

24 J<br />

120 F<br />

110–120/220–240 a A<br />

200–208 D<br />

220–240 G<br />

277 L<br />

220–240/440–480 a C<br />

440–480 H<br />

575–600 E<br />

For other voltages and frequencies,<br />

see Factory Modifications page 17-114.<br />

Standard Width Enclosure with Solid State Overload, 3-Phase, 3-Pole<br />

Max Hp<br />

Overload<br />

Enclosure<br />

200<br />

Volts<br />

Disc.<br />

Amp<br />

Rating<br />

NEMA 1<br />

General Purpose<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

304 Stainless Steel<br />

NEMA 4X Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

230<br />

Volts<br />

460<br />

Volts<br />

575<br />

Volts<br />

NEMA<br />

Size<br />

Half<br />

Size<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

1<br />

⁄6<br />

1<br />

⁄6<br />

1<br />

⁄3<br />

1<br />

⁄2 0 — 0.25–1 A 30 25CUA92B* 25CUA92W* 25CUA92F* 25CUA92N*<br />

1<br />

⁄2<br />

3<br />

⁄4 1 1 ⁄2 2 0 — 0.75–3.4 A 30 25CUB92B* 25CUB92W* 25CUB92F* 25CUB92N*<br />

2 2 5 5 0 — 3–12 A1 30 25CUC92B* 25CUC92W* 25CUC92F* 25CUC92N*<br />

3 3 — — 0 — 5.5–22 A1 30 25CUD92B* 25CUD92W* 25CUD92F* 25CUD92N*<br />

1<br />

⁄6<br />

1<br />

⁄6<br />

1<br />

⁄3<br />

1<br />

⁄2 1 — 0.25–1 A 30 25DUA92B* 25DUA92W* 25DUA92F* 25DUA92N*<br />

1<br />

⁄2<br />

3<br />

⁄4 1 1 ⁄2 2 1 — 0.75–3.4 A 30 25DUB92B* 25DUB92W* 25DUB92F* 25DUB92N*<br />

2 2 5 5 1 — 3–12 A1 30 25DUC92B* 25DUC92W* 25DUC92F* 25DUC92N*<br />

3 3 10 10 1 — 5.5–22 A1 30 25DUD92B* 25DUD92W* 25DUD92F* 25DUD92N*<br />

7 1 ⁄2 7 1 ⁄2 — — 1 — 10–40 A1 60 25DUE92B* 25DUE92W* 25DUE92F* 25DUE92N*<br />

10 10 15 15 — 1 3 ⁄4 10–40 A1 60 25EUE92B* 25EUE92W* 25EUE92F* 25EUE92N*<br />

10 15 25 25 2 — 13–52 B 60 25FUF92B* 25FUF92W* 25FUF92F* 25FUF92N*<br />

15 20 30 30 — 2 1 ⁄2 25–100 B 100 25GUG92B* 25GUG92W* 25GUG92F* 25GUG92N*<br />

20 25 50 50 3 — 25–100 B 100 25HUG92B* 25HUG92W* 25HUG92F* 25HUG92N*<br />

30 40 75 75 — 3 1 ⁄2 50–200 B 200 25IUH92B* 25IUH92W* 25IUH92F* 25IUH92N*<br />

40 50 100 100 4 — 50–200 B 200 25JUH92B* 25JUH92W* 25JUH92F* 25JUH92N*<br />

75 100 200 200 5 — 55–250 — 400 25LPU92B* — — — — 25LPU92N*<br />

150 200 400 400 6 — 160–630 — 600 25MPX92B* — — — — 25MPX92N*<br />

— 300 600 600 7 — 400–1220 A1+CT 1200 25NUN92B* — — — — 25NUN92N*<br />

— 450 900 900 8 — 400–1220 A1+CT 1600 25PUN92B* — — — — 25PUN92N*<br />

List<br />

Price $<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

a Dual voltage coils not available in starter sizes 5–8.<br />

F coil 100-250V AC 50/60Hz, or DC,<br />

H coil 150-500V AC 50/60Hz, or DC<br />

Only available<br />

F coil 100-250V AC 50/60Hz, or DC<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-25


Combination Reversing Heavy Duty Starters<br />

MCP Type, Class 26<br />

Revised on 03/31/20<br />

Selection<br />

Ordering Information<br />

Replace the (*) with a letter from the coil table. Dual voltage coils are<br />

wired on high voltage unless specified on order.<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-147.<br />

Wiring Diagrams see page 17-159.<br />

Replacement Parts see page 17-120.<br />

Coil Table<br />

60Hz Voltage<br />

Letter<br />

24 J<br />

120 F<br />

110–120/220–240 a A<br />

200–208 D<br />

220–240 G<br />

277 L<br />

220–240/440–480 a C<br />

440–480 H<br />

575–600 E<br />

For other voltages and frequencies,<br />

see Factory Modifications page 17-114.<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Standard Width Enclosure with Solid State Overload, 3-Phase, 3-Pole<br />

Max Hp<br />

200<br />

Volts<br />

1<br />

⁄2<br />

Motor<br />

Circuit<br />

Interruter<br />

ETI Amps<br />

Overload<br />

Enclosure<br />

NEMA 1<br />

General Purpose<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

304 Stainless Steel<br />

NEMA 4X Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

230 460 575 NEMA Half<br />

Amp Frame Catalog List Catalog List Catalog List Catalog<br />

Volts Volts Volts Size Size<br />

Range Size Number Price $ Number Price $ Number Price $ Number<br />

1<br />

⁄2 1 1 0 — 3 0.75–3.4 A 26CUB92B* 26CUB92W* 26CUB92F* 26CUB92N*<br />

2 2 5 5 0 — 10 3–12 A1 26CUC92B* 26CUC92W* 26CUC92F* 26CUC92N*<br />

3 3 — — 0 — 25 5.5–22 A1 26CUD92B* 26CUD92W* 26CUD92F* 26CUD92N*<br />

1<br />

⁄2<br />

1<br />

⁄2 1 1 1 — 3 0.75–3.4 A 26DUB92B* 26DUB92W* 26DUB92F* 26DUB92N*<br />

2 2 5 5 1 — 10 3–12 A1 26DUC92B* 26DUC92W* 26DUC92F* 26DUC92N*<br />

3 3 7 1 ⁄2 10 1 — 25 5.5–22 A1 26DUD92B* 26DUD92W* 26DUD92F* 26DUD92N*<br />

7 1 ⁄2 7 1 ⁄2 10 — 1 — 30 10–40 A1 26DUE92B* 26DUE92W* 26DUE92F* 26DUE92N*<br />

— — 15 15 — 1 3 ⁄4 40 10–40 A1 26EUE92B* 26EUE92W* 26EUE92F* 26EUE92N*<br />

10 15 25 25 2 — 50 13–52 B 26FUF92B* 26FUF92W* 26FUF92F* 26FUF92N*<br />

15 20 30 30 — 2 1 ⁄2 100 25–100 B 26GUG92B* 26GUG92W* 26GUG92F* 26GUG92N*<br />

25 30 50 50 3 — 125 25–100 B 26HUG92B* 26HUG92W* 26HUG92F* 26HUG92N*<br />

30 40 75 75 — 3 1 ⁄2 125 50–200 B 26IUH92B* 26IUH92W* 26IUH92F* 26IUH92N*<br />

40 50 100 100 4 — 150 50–200 B 26JUH92B* 26JUH92W* 26JUH92F* 26JUH92N*<br />

50 75 150 200 5 — 250 55–250 — 26LPT92B* — — — — 26LPT92N*<br />

75 100 200 — 5 — 400 55–250 — 26LPU92B* — — — — 26LPU92N*<br />

100 125 250 300 6 — 400 160–630 — 26MPW92B* — — — — 26MPW92N*<br />

150 200 400 400 6 — 600 160–630 — 26MPX92B* — — — — 26MPX92N*<br />

— 250 500 500 7* — 800 400–1220 A1+CT 26NUV92B* — — — — 26NUV92N*<br />

— 300 600 600 7* — 1000 400–1220 A1+CT 26NUY92B* — — — — 26NUY92N*<br />

— 400 800 800 8 — 1200 400–1220 A1+CT 26PUW92B* — — — — 26PUW92N*<br />

— 450 900 900 8 — 1600 400–1220 A1+CT 26PUZ92B* — — — — 26PUZ92N*<br />

List<br />

Price $<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

a Dual voltage coils not available in starter sizes 5–8.<br />

F coil 100-250V AC 50/60Hz, or DC,<br />

H coil 150-500V AC 50/60Hz, or DC<br />

Only available<br />

F coil 100-250V AC 50/60Hz, or DC<br />

17-26<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Two Speed Heavy Duty Starters<br />

Features and Benefits<br />

Revised on 03/31/20<br />

General<br />

Features<br />

b Rugged Industrial Design<br />

b Dual Voltage, Dual Frequency Coils<br />

b Compact Design<br />

b Snap-On Front Removable Auxiliary<br />

Contacts<br />

b Electrical and Mechanical Interlocks<br />

b Half Sizes — Space and Cost Savings<br />

b Industrial Type Disconnect<br />

Operating Handle<br />

b Visible Blade Disconnect Thru Size 4<br />

b Adjustable Motor Circuit Protector<br />

b 100,000 Amp Fault Protection with<br />

MCP or Class R Fuses<br />

b Pilot Device Locations identified<br />

on All Enclosures<br />

b UL Listed File #E14900<br />

b CSA Certified File #LR6535<br />

Applications<br />

Multi-speed magnetic starters<br />

automatically reconnect multi-speed<br />

motor windings for the desired speed in<br />

response to a signal received from push<br />

button stations or other pilot devices.<br />

These starters are available for two<br />

speed motors.<br />

Consequent Pole multi-speed motors<br />

having two speeds on a single winding<br />

(consequent pole) require a starter<br />

which reconnects the motor leads to<br />

half the number of effective motor<br />

poles at the high speed point. In this<br />

type of motor, the low speed is one<br />

half the high speed.<br />

Separate Windings motors having<br />

separate windings for each speed<br />

provide more varied speed<br />

combinations in that the low speed<br />

need not be one half the high speed.<br />

Starters for separate winding<br />

motors consist of a starter unit<br />

for each speed.<br />

Multi-speed motor starters are available<br />

for constant torque, variable torque and<br />

constant horsepower motors.<br />

Constant Torque motors maintain<br />

constant torque at all speeds.<br />

Horsepower varies directly with speed.<br />

This type of motor is applicable to<br />

conveyors, mills and similar<br />

applications.<br />

Variable Torque motors produce a<br />

torque characteristic which varies as<br />

the square of the speed. This type of<br />

motor is applicable to fans, blowers<br />

and centrifugal pumps.<br />

Constant Horsepower motors<br />

maintain constant horsepower at all<br />

speeds and therefore torque varies<br />

inversely with speed. This type of<br />

motor is applicable where the same<br />

horsepower is required at all speeds.<br />

The higher current required at<br />

low speed requires derating on<br />

starters for constant horsepower<br />

applications. This type of motor is<br />

applicable to metal working machines<br />

such as drills, lathes, mills, bending<br />

machines, punch presses, and power<br />

wrenches.<br />

Operation<br />

Magnetic starters for multi-speed<br />

applications select the desired speed<br />

in accordance with the pilot control.<br />

The shock to machinery upon the<br />

reduction of speed is greater than when<br />

the speed is increased. Therefore, the<br />

pilot control should be wired so that the<br />

stop button must be depressed before<br />

dropping to a lower speed or time<br />

delays should be used for applications<br />

requiring full automatic operations. The<br />

multi-speed controls are available with<br />

the necessary interlocks or relays to<br />

provide this type of operation.<br />

These controls may be modified for<br />

compelling or acceleration pilot control.<br />

Selective Control permits the<br />

operator to start the motor at any speed<br />

and to change to a higher speed by<br />

merely pushing a button. To change to<br />

a lower speed it is necessary to<br />

first depress the stop button and to<br />

then press the proper speed button.<br />

Selective control is a function of the<br />

pilot control selected and requires no<br />

starter modifications.<br />

Compelling Control requires that the<br />

motor always be started at the lower<br />

speed and that the push buttons be<br />

operated in speed sequence to go to<br />

the next higher speed. To change to a<br />

lower speed, the stop button must be<br />

depressed and then the push buttons<br />

operated in speed sequence until the<br />

desired speed is reached. Compelling<br />

control can be added from the factory<br />

modification section page 17-117.<br />

Acceleration Control provides that<br />

the motor be accelerated auto matically<br />

with timers by progressively energizing<br />

the controls from the push button<br />

station from the lowest to highest<br />

speed. To change to a lower speed the<br />

stop button is depressed and then it is<br />

necessary to proceed as if starting from<br />

rest. Acceleration control can be added<br />

from the factory modification section<br />

page 17-117.<br />

Deceleration Control provides that<br />

the motor be decelerated auto matically<br />

with a timer when going from high<br />

speed to low speed. The timer allows<br />

the motor to decelerate from high<br />

speed to a lower speed before<br />

automatically restarting the motor in<br />

low speed. Deceleration control can<br />

be added from the factory modification<br />

section page 17-117.<br />

Open Style Two Speed Starter<br />

(ESP100 Overload)<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-27


Two Speed Heavy Duty Starters<br />

Constant or Variable Torque with Solid State Overload, Class 30<br />

Revised on 03/31/20<br />

Selection<br />

2S2W Starter<br />

(ESP200 Overload)<br />

Ordering Information<br />

Replace the (*) with a letter from<br />

the coil table. Dual voltage coils<br />

are wired on high voltage unless<br />

specified on order.<br />

Replace the (†) with the letter that<br />

corresponds to the correct low<br />

speed FLA in the FLA table. <br />

Field Modification Kits see page<br />

17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-136.<br />

Wiring Diagrams see page 17-160.<br />

Replacement Parts see page 17-120.<br />

Coil Table<br />

60Hz Voltage<br />

Letter<br />

24 J<br />

120 F<br />

110–120/220–240 A<br />

200–208 D<br />

220–240 G<br />

277 L<br />

220–240/440–480 C<br />

440–480 H<br />

575–600 E<br />

For other voltages and frequencies,<br />

see Factory Modifications page 17-114.<br />

Low Speed FLA Table<br />

OLR<br />

Size FLA Frame Size †<br />

0,1 0.25–1 A A<br />

0,1 0.75–3.4 A B<br />

0,1 3–12 A1 C<br />

0,1 5.5–22 A1 D<br />

0-1 3 /4 10–40 A1 E<br />

2-3 13–52 B F<br />

2-3 25–100 B G<br />

3 1 /2-4 50–200 B H<br />

One Winding Consequent Pole, 3-Phase (Constant or Variable Torque)<br />

Max Hp<br />

Overload Enclosure<br />

Open Type<br />

NEMA 1<br />

NEMA 4/4X Stainless<br />

Standard Auxiliary Contacts General Purpose<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

304 Stainless Steel<br />

NEMA 4X Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

200 230 460 575 NEMA Half Amp Frame Catalog List Catalog List Catalog List Catalog List Catalog<br />

Volts Volts Volts Volts Size Size Range Size Number Price $ Number Price $ Number Price $ Number Price $ Number<br />

1<br />

⁄2 3<br />

⁄4 1 1 ⁄2 2 0 — 0.75–3.4 A 30CUB†32A2V* 30CUB†32B2V* 30CUB†32W2V* 30CUB†32F2V* 30CUB†3202V*<br />

2 2 5 5 0 — 3–12 A1 30CUC†32A2V* 30CUC†32B2V* 30CUC†32W2V* 30CUC†32F2V* 30CUC†3202V*<br />

3 3 — — 0 — 5.5–22 A1 30CUD†32A2V* 30CUD†32B2V* 30CUD†32W2V* 30CUD†32F2V* 30CUD†3202V*<br />

1<br />

⁄2 3<br />

⁄4 1 1 ⁄2 1 1 ⁄2 1 — 0.75–3.4 A 30DUB†32A2V* 30DUB†32B2V* 30DUB†32W2V* 30DUB†32F2V* 30DUB†3202V*<br />

2 2 5 5 1 — 3–12 A1 30DUC†32A2V* 30DUC†32B2V* 30DUC†32W2V* 30DUC†32F2V* 30DUC†3202V*<br />

3 3 10 10 1 — 5.5–22 A1 30DUD†32A2V* 30DUD†32B2V* 30DUD†32W2V* 30DUD†32F2V* 30DUD†3202V*<br />

7 1 ⁄2 7 1 ⁄2 — — 1 — 10–40 A1 30DUE†32A2V* 30DUE†32B2V* 30DUE†32W2V* 30DUE†32F2V* 30DUE†3202V*<br />

10 10 15 15 — 1 3 ⁄4 10–40 A1 30EUE†32A2V* 30EUE†32B2V* 30EUE†32W2V* 30EUE†32F2V* 30EUE†3202V*<br />

10 15 25 25 2 — 13–52 B 30FUF†32A2V* 30FUF†32B2V* 30FUF†32W2V* 30FUF†32F2V* 30FUF†3202V*<br />

15 20 30 30 — 2 1 ⁄2 25–100 B 30GUG†32A2V* 30GUG†32B2V* 30GUG†32W2V* 30GUG†32F2V* 30GUG†3202V*<br />

25 30 50 50 3 — 25–100 B 30HUG†32A2V* 30HUG†32B2V* 30HUG†32W2V* 30HUG†32F2V* 30HUG†3202V*<br />

30 40 75 75 — 3 1 ⁄2 50–200 B 30IUH†32A2V* 30IUH†32B2V* 30IUH†32W2V* 30IUH†32F2V* 30IUH†3202V*<br />

40 50 100 100 4 — 50–200 B 30JUH†32A2V* 30JUH†32B2V* 30JUH†32W2V* 30JUH†32F2V* 30JUH†3202V*<br />

Two Separate Windings, 3-Phase (Constant or Variable Torque)<br />

Max Hp<br />

Overload Enclosure<br />

Open Type <br />

NEMA 1<br />

Standard Auxiliary Contacts General Purpose<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

304 Stainless Steel<br />

316 Stainless Steel (Optional)<br />

NEMA 4X Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

200 230 460 575 NEMA Half Amp Frame Catalog List Catalog List Catalog List Catalog List Catalog<br />

Volts Volts Volts Volts Size Size Range Size Number Price $ Number Price $ Number Price $ Number Price $ Number<br />

1<br />

⁄2 3<br />

⁄4 1 1 ⁄2 2 0 — 0.75–3.4 A 30CUB†32A1V* 30CUB†32B1V* 30CUB†32W1V* 30CUB†32F1V* 30CUB†3201V*<br />

2 2 5 5 0 — 3–12 A1 30CUC†32A1V* 30CUC†32B1V* 30CUC†32W1V* 30CUC†32F1V* 30CUC†3201V*<br />

3 3 — — 0 — 5.5–22 A1 30CUD†32A1V* 30CUD†32B1V* 30CUD†32W1V* 30CUD†32F1V* 30CUD†3201V*<br />

1<br />

⁄2 3<br />

⁄4 1 1 ⁄2 1 1 ⁄2 1 — 0.75–3.4 A 30DUB†32A1V* 30DUB†32B1V* 30DUB†32W1V* 30DUB†32F1V* 30DUB†3201V*<br />

2 2 5 5 1 — 3–12 A1 30DUC†32A1V* 30DUC†32B1V* 30DUC†32W1V* 30DUC†32F1V* 30DUC†3201V*<br />

3 3 10 10 1 — 5.5–22 A1 30DUD†32A1V* 30DUD†32B1V* 30DUD†32W1V* 30DUD†32F1V* 30DUD†3201V*<br />

7 1 ⁄2 7 1 ⁄2 — — 1 — 10–40 A1 30DUE†32A1V* 30DUE†32B1V* 30DUE†32W1V* 30DUE†32F1V* 30DUE†3201V*<br />

10 10 15 15 — 1 3 ⁄4 10–40 A1 30EUE†32A1V* 30EUE†32B1V* 30EUE†32W1V* 30EUE†32F1V* 30EUE†3201V*<br />

10 15 25 25 2 — 13–52 B 30FUF†32A1V* 30FUF†32B1V* 30FUF†32W1V* 30FUF†32F1V* 30FUF†3201V*<br />

15 20 30 30 — 2 1 ⁄2 25–100 B 30GUG†32A1V* 30GUG†32B1V* 30GUG†32W1V* 30GUG†32F1V* 30GUG†3201V*<br />

25 30 50 50 3 — 25–100 B 30HUG†32A1V* 30HUG†32B1V* 30HUG†32W1V* 30HUG†32F1V* 30HUG†3201V*<br />

30 40 75 75 — 3 1 ⁄2 50–200 B 30IUH†32A1V* 30IUH†32B1V* 30IUH†32W1V* 30IUH†32F1V* 30IUH†3201V*<br />

40 50 100 100 4 — 50–200 B 30JUH†32A1V* 30JUH†32B1V* 30JUH†32W1V* 30JUH†32F1V* 30JUH†3201V*<br />

List<br />

Price $<br />

List<br />

Price $<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

If motor FLA are unknown, select overload on the<br />

basis that low speed FLA will be no greater than 50%<br />

of high speed FLA.<br />

b Auxiliary contacts 30C-30E 4th pole built-in<br />

30F-30J 2 NO & 2 NC<br />

17-28<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Two Speed Heavy Duty Starters<br />

Constant HP with Solid State Overload, Class 30<br />

Revised on 03/31/20<br />

Selection<br />

Ordering Information<br />

Coil Table<br />

High/Low Speed FLA Table <br />

2S2W Starter<br />

(ESP200 Overload)<br />

Replace the (*) with a letter from<br />

the coil table. Dual voltage coils<br />

are wired on high voltage unless<br />

specified on order.<br />

Replace the (†) with the letter that<br />

corresponds to the correct FLA in<br />

High/Low Speed FLA Table. <br />

Field Modification Kits see page<br />

17-102.<br />

Factory Modifications see page<br />

17-114.<br />

Dimensions see page 17-136.<br />

Wiring Diagrams see page 17-160.<br />

Replacement Parts see page 17-120.<br />

60Hz Voltage<br />

Letter<br />

24 J<br />

120 F<br />

110–120/220–240 A<br />

200–208 D<br />

220–240 G<br />

277 L<br />

220–240/440–480 C<br />

440–480 H<br />

575–600 E<br />

For other voltages and frequencies,<br />

see Factory Modifications page 17-114.<br />

OLR<br />

Size FLA Frame Size †<br />

0,1 0.25–1 A A<br />

0,1 0.75–3.4 A B<br />

0,1 3–12 A1 C<br />

0,1 5.5–22 A1 D<br />

0-1 3 /4 10–40 A1 E<br />

2-3 13–52 B F<br />

2-3 25–100 B G<br />

3 1 /2-4 50–200 B H<br />

* First (†) for high speed, second<br />

(†) for low speed. Use motor nameplate<br />

to select FLA. If motor FLA<br />

are unknown, select overload on<br />

the bases that the low speed FLA<br />

will be no greater than 50 % of high<br />

speed FLA.<br />

One Winding Consequent Pole, 3-Phase (Constant Horsepower)<br />

Max Hp<br />

Enclosure<br />

Open Type<br />

Standard Auxiliary Contacts<br />

NEMA 1<br />

General Purpose<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

304 Stainless Steel<br />

NEMA 4X Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

200<br />

Volts<br />

230<br />

Volts<br />

460<br />

Volts<br />

575<br />

Volts<br />

NEMA<br />

Size<br />

Half<br />

Size<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Two Separate Windings, 3-Phase (Constant Horsepower)<br />

Max Hp<br />

Enclosure<br />

Open Type<br />

Standard Auxiliary Contacts<br />

Catalog<br />

Number<br />

NEMA 1<br />

General Purpose<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

304 Stainless Steel<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

NEMA 4X Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

2 2 3 3 0 — 30CU††32A2H* 30CU††32B2H* 30CU††32W2H* 30CU††32F2H* 30CU††3202H*<br />

5 5 7 1 ⁄2 7 1 ⁄2 1 — 30DU††32A2H* 30DU††32B2H* 30DU††32W2H* 30DU††32F2H* 30DU††3202H*<br />

7 1 ⁄2 7 1 ⁄2 10 10 — 1 3 ⁄4 30EU††32A2H* 30EU††32B2H* 30EU††32W2H* 30EU††32F2H* 30EU††3202H*<br />

7 1 ⁄2 10 20 20 2 — 30FU††32A2H* 30FU††32B2H* 30FU††32W2H* 30FU††32F2H* 30FU††3202H*<br />

10 15 25 25 — 2 1 ⁄2 30GU††32A2H* 30GU††32B2H* 30GU††32W2H* 30GU††32F2H* 30GU††3202H*<br />

20 25 40 40 3 — 30HU††32A2H* 30HU††32B2H* 30HU††32W2H* 30HU††32F2H* 30HU††3202H*<br />

25 30 50 50 — 3 1 ⁄2 30IU††32A2H* 30IU††32B2H* 30IU††32W2H* 30IU††32F2H* 30IU††3202H*<br />

30 40 75 75 4 — 30JU††32A2H* 30JU††32B2H* 30JU††32W2H* 30JU††32F2H* 30JU††3202H*<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

List<br />

Price $<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

200<br />

Volts<br />

230<br />

Volts<br />

460<br />

Volts<br />

575<br />

Volts<br />

NEMA<br />

Size<br />

Half<br />

Size<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

2 2 3 3 0 — 30CU††32A1H* 30CU††32B1H* 30CU††32W1H* 30CU††32F1H* 30CU††3201H*<br />

5 5 7 1 ⁄2 7 1 ⁄2 1 — 30DU††32A1H* 30DU††32B1H* 30DU††32W1H* 30DU††32F1H* 30DU††3201H*<br />

7 1 ⁄2 7 1 ⁄2 10 10 — 13⁄4 30EU††32A1H* 30EU††32B1H* 30EU††32W1H* 30EU††32F1H* 30EU††3201H*<br />

7 1 ⁄2 10 20 20 2 — 30FU††32A1H* 30FU††32B1H* 30FU††32W1H* 30FU††32F1H* 30FU††3201H*<br />

10 15 25 25 — 2 1 ⁄2 30GU††32A1H* 30GU††32B1H* 30GU††32W1H* 30GU††32F1H* 30GU††3201H*<br />

20 25 40 40 3 — 30HU††32A1H* 30HU††32B1H* 30HU††32W1H* 30HU††32F1H* 30HU††3201H*<br />

25 30 50 50 — 3 1 ⁄2 30IU††32A1H* 30IU††32B1H* 30IU††32W1H* 30IU††32F1H* 30IU††3201H*<br />

30 40 75 75 4 — 30JU††32A1H* 30JU††32B1H* 30JU††32W1H* 30JU††32F1H* 30JU††3201H*<br />

List<br />

Price $<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

First (†) for high speed, second (†) for low speed. Use<br />

motor nameplate information to select FLA. If motor<br />

FLA are unknown, select overload on the basis that<br />

low speed FLA will be no greater than 50% of high<br />

speed FLA.<br />

Auxiliary contacts<br />

30C-30E 4th pole built-in<br />

30F-30J 2 NO & 2 NC<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-29


Combination Two Speed Heavy Duty Starters<br />

Non-Fusible, Constant or Variable Torque with Solid State Overload, Class 32<br />

Revised on 03/31/20<br />

Selection<br />

Ordering Information<br />

Replace the (*) with a letter from<br />

the coil table. Dual voltage coils<br />

are wired on high voltage unless<br />

specified on order.<br />

Replace the (†) with the letter that<br />

corresponds to the correct low<br />

speed FLA in the FLA table. <br />

Fuse clips see page 17-115.<br />

Field Modification Kits see page<br />

17-102.<br />

Factory Modifications see page<br />

17-114.<br />

Dimensions see page 17-149.<br />

Wiring Diagrams see page 17-160.<br />

Replacement Parts see page 17-120.<br />

Coil Table<br />

60Hz Voltage<br />

Letter<br />

24 J<br />

120 F<br />

110–120/220–240 a A<br />

200–208 D<br />

220–240 G<br />

277 L<br />

220–240/440–480 a C<br />

440–480 H<br />

575–600 E<br />

For other voltages and frequencies,<br />

see Factory Modifications page 17-114.<br />

Low Speed FLA Table<br />

OLR<br />

Size FLA Frame Size †<br />

0,1 0.25–1 A A<br />

0,1 0.75–3.4 A B<br />

0,1 3–12 A1 C<br />

0,1 5.5–22 A1 D<br />

0-1 3 /4 10–40 A1 E<br />

2-3 13–52 B F<br />

2-3 25–100 B G<br />

3 1 /2-4 50–200 B H<br />

NEMA & General<br />

Purpose Control<br />

17<br />

One Winding Consequent Pole, 3-Phase (Constant or Variable Torque)<br />

Max Hp<br />

Overload<br />

Enclosure<br />

NEMA 1<br />

General Purpose<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

304 Stainless Steel<br />

NEMA 4X Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

Disc.<br />

200 230 460 575 NEMA Half Amp Frame Amp Catalog<br />

List Catalog<br />

List Catalog List Catalog<br />

Volts Volts Volts Volts Size Size Range Size Range Number<br />

Price $ Number<br />

Price $ Number Price $ Number<br />

1<br />

⁄2 3<br />

⁄4 1 1 ⁄2 2 0 — 0.75–3.4 A 30 32CUB†92B2V2* 32CUB†92W2V2* 32CUB†92F2V2* 32CUB†92N2V2*<br />

2 2 5 5 0 — 3–12 A1 30 32CUC†92B2V2* 32CUC†92W2V2* 32CUC†92F2V2* 32CUC†92N2V2*<br />

3 3 — — 0 — 5.5–22 A1 30 32CUD†92B2V2* 32CUD†92W2V2* 32CUD†92F2V2* 32CUD†92N2V2*<br />

1<br />

⁄2 3<br />

⁄4 1 1 ⁄2 1 1 ⁄2 1 — 0.75–3.4 A 30 32DUB†92B2V2* 32DUB†92W2V2* 32DUB†92F2V2* 32DUB†92N2V2*<br />

2 2 5 5 1 — 3–12 A1 30 32DUC†92B2V2* 32DUC†92W2V2* 32DUC†92F2V2* 32DUC†92N2V2*<br />

3 3 10 10 1 — 5.5–22 A1 30 32DUD†92B2V2* 32DUD†92W2V2* 32DUD†92F2V2* 32DUD†92N2V2*<br />

7 1 ⁄2 7 1 ⁄2 — — 1 — 10–40 A1 60 32DUE†92B2V2* 32DUE†92W2V2* 32DUE†92F2V2* 32DUE†92N2V2*<br />

10 10 15 15 — 1 3 ⁄4 10–40 A1 60 32EUE†92B2V2* 32EUE†92W2V2* 32EUE†92F2V2* 32EUE†92N2V2*<br />

10 15 25 25 2 — 13–52 B 60 32FUF†92B2V2* 32FUF†92W2V2* 32FUF†92F2V2* 32FUF†92N2V2*<br />

15 20 30 30 — 2 1 ⁄2 25–100 B 100 32GUG†92B2V2* 32GUG†92W2V2* 32GUG†92F2V2* 32GUG†92N2V2*<br />

20 25 50 50 3 — 25–100 B 100 32HUG†92B2V2* 32HUG†92W2V2* 32HUG†92F2V2* 32HUG†92N2V2*<br />

30 40 75 75 — 3 1 ⁄2 50–200 B 200 32IUH†92B2V2* 32IUH†92W2V2* 32IUH†92F2V2* 32IUH†92N2V2*<br />

40 50 100 100 4 — 50–200 B 200 32JUH†92B2V2* 32JUH†92W2V2* 32JUH†92F2V2* 32JUH†92N2V2*<br />

List<br />

Price $<br />

CONTROL<br />

PRODUCTS<br />

Two Separate Windings, 3-Phase (Constant or Variable Torque)<br />

Max Hp<br />

Overload<br />

Enclosure<br />

NEMA 1<br />

NEMA 4/4X Stainless<br />

General Purpose<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

304 Stainless Steel<br />

NEMA 4X Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

Disc.<br />

200 230 460 575 NEMA Half Amp Frame Amp Catalog<br />

List Catalog<br />

List Catalog List Catalog<br />

Volts Volts Volts Volts Size Size Range Size Range Number<br />

Price $ Number<br />

Price $ Number Price $ Number<br />

1<br />

⁄2 3<br />

⁄4 1 1 ⁄2 2 0 — 0.75–3.4 A 30 32CUB†92B1V2* 32CUB†92W1V2* 32CUB†92F1V2* 32CUB†92N1V2*<br />

2 2 5 5 0 — 3–12 A1 30 32CUC†92B1V2* 32CUC†92W1V2* 32CUC†92F1V2* 32CUC†92N1V2*<br />

3 3 — — 0 — 5.5–22 A1 30 32CUD†92B1V2* 32CUD†92W1V2* 32CUD†92F1V2* 32CUD†92N1V2*<br />

1<br />

⁄2 3<br />

⁄4 1 1 ⁄2 1 1 ⁄2 1 — 0.75–3.4 A 30 32DUB†92B1V2* 32DUB†92W1V2* 32DUB†92F1V2* 32DUB†92N1V2*<br />

2 2 5 5 1 — 3–12 A1 30 32DUC†92B1V2* 32DUC†92W1V2* 32DUC†92F1V2* 32DUC†92N1V2*<br />

3 3 10 10 1 — 5.5–22 A1 30 32DUD†92B1V2* 32DUD†92W1V2* 32DUD†92F1V2* 32DUD†92N1V2*<br />

7 1 ⁄2 7 1 ⁄2 — — 1 — 10–40 A1 60 32DUE†92B1V2* 32DUE†92W1V2* 32DUE†92F1V2* 32DUE†92N1V2*<br />

10 10 15 15 — 1 3 ⁄4 10–40 A1 60 32EUE†92B1V2* 32EUE†92W1V2* 32EUE†92F1V2* 32EUE†92N1V2*<br />

10 15 25 25 2 — 13–52 B 60 32FUF†92B1V2* 32FUF†92W1V2* 32FUF†92F1V2* 32FUF†92N1V2*<br />

15 20 30 30 — 2 1 ⁄2 25–100 B 100 32GUG†92B1V2* 32GUG†92W1V2* 32GUG†92F1V2* 32GUG†92N1V2*<br />

20 25 50 50 3 — 25–100 B 100 32HUG†92B1V2* 32HUG†92W1V2* 32HUG†92F1V2* 32HUG†92N1V2*<br />

30 40 75 75 — 3 1 ⁄2 50–200 B 200 32IUH†92B1V2* 32IUH†92W1V2* 32IUH†92F1V2* 32IUH†92N1V2*<br />

40 50 100 100 4 — 50–200 B 200 32JUH†92B1V2* 32JUH†92W1V2* 32JUH†92F1V2* 32JUH†92N1V2*<br />

List<br />

Price $<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

a Dual voltage coils not available in modified starters.<br />

If motor FLA are unknown, select overload on the<br />

basis that low speed FLA will be no greater than 50%<br />

of high speed FLA.<br />

17-30<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Combination Two Speed Heavy Duty Starters<br />

Non-Fusible, Constant Horsepower with Solid State Overload, Class 32<br />

Revised on 03/31/20<br />

Selection<br />

Ordering Information<br />

Replace the (*) with a letter from<br />

the coil table. Dual voltage coils are<br />

wired on high voltage unless<br />

specified on order.<br />

Replace the (†) with the letter that<br />

corresponds to the correct FLA in the<br />

High/Low Speed FLA Table. <br />

Fuse clips see page 17-115.<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-149.<br />

Wiring Diagrams see page 17-160.<br />

Replacement Parts see page 17-120.<br />

Coil Table<br />

60Hz Voltage Letter<br />

24 J<br />

120 F<br />

110–120/220–240 a A<br />

200–208 D<br />

220–240 G<br />

277 L<br />

220–240/440–480 a C<br />

440–480 H<br />

575–600 E<br />

For other voltages and<br />

frequencies see Factory<br />

Modifications page 17-114.<br />

High/Low Speed FLA Table <br />

OLR<br />

Size FLA Frame Size †<br />

0,1 0.25–1 A A<br />

0,1 0.75–3.4 A B<br />

0,1 3–12 A1 C<br />

0,1 5.5–22 A1 D<br />

0-1 3 /4 10–40 A1 E<br />

2-3 13–52 B F<br />

2-3 25–100 B G<br />

3 1 /2-4 50–200 B H<br />

* First (†) for high speed, second<br />

(†) for low speed. Use motor nameplate<br />

to select FLA. If motor FLA<br />

are unknown, select overload on<br />

the bases that the low speed FLA<br />

will be no greater than 50 % of high<br />

speed FLA.<br />

One Winding Consequent Pole, 3-Phase (Constant Horsepower)<br />

Max Hp<br />

200 230 460 575 NEMA<br />

Volts Volts Volts Volts Size<br />

Half<br />

Size<br />

Overload<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

Disc.<br />

Amp<br />

Range<br />

Enclosure<br />

NEMA 1<br />

General Purpose<br />

Catalog<br />

Number<br />

Two Separate Windings, 3-Phase (Constant Horsepower)<br />

List<br />

Price $<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

304 Stainless Steel<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

NEMA 4X Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

Catalog<br />

Number<br />

2 2 3 3 0 — — — 30 32CU††92B2H2* 32CU††92W2H2* 4054.00 32CU††92F2H2* 32CU††92N2H2*<br />

5 5 7 1 ⁄2 7 1 ⁄2 1 — — — 30 32DU††92B2H2* 32DU††92W2H2* 4173.00 32DU††92F2H2* 32DU††92N2H2*<br />

7 1 ⁄2 7 1 ⁄2 10 10 — 1 3 ⁄4 — — 60 32EU††92B2H2* 32EU††92W2H2* 4873.00 32EU††92F2H2* 32EU††92N2H2*<br />

7 1 ⁄2 10 20 20 2 — — — 60 32FU††92B2H2* 32FU††92W2H2* 6146.00 32FU††92F2H2* 32FU††92N2H2*<br />

10 15 25 25 — 2 1 ⁄2 — — 100 32GU††92B2H2* 32GU††92W2H2* 7219.00 32GU††92F2H2* 32GU††92N2H2*<br />

20 25 40 40 3 — — — 100 32HU††92B2H2* 32HU††92W2H2* 9321.00 32HU††92F2H2* 32HU††92N2H2*<br />

25 30 50 50 — 3 1 ⁄2 — — 200 32IU††92B2H2* 32IU††92W2H2* 18079.00 32IU††92F2H2* 32IU††92N2H2*<br />

30 40 75 75 4 — — — 200 32JU††92B2H2* 32JU††92W2H2* 19263.00 32JU††92F2H2* 32JU††92N2H2*<br />

Max Hp<br />

200 230 460 575 NEMA<br />

Volts Volts Volts Volts Size<br />

Half<br />

Size<br />

Overload<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

Disc.<br />

Amp<br />

Range<br />

Enclosure<br />

NEMA 1<br />

General Purpose<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

304 Stainless Steel<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

NEMA 4X Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

Catalog<br />

Number<br />

2 2 3 3 0 — — — 30 32CU††92B1H2* 32CU††92W1H2* 32CU††92F1H2* 32CU††92N1H2*<br />

5 5 7 1 ⁄2 7 1 ⁄2 1 — — — 30 32DU††92B1H2* 32DU††92W1H2* 32DU††92F1H2* 32DU††92N1H2*<br />

7 1 ⁄2 7 1 ⁄2 10 10 — 1 3 ⁄4 — — 60 32EU††92B1H2* 32EU††92W1H2* 32EU††92F1H2* 32EU††92N1H2*<br />

7 1 ⁄2 10 20 20 2 — — — 60 32FU††92B1H2* 32FU††92W1H2* 32FU††92F1H2* 32FU††92N1H2*<br />

10 15 25 25 — 2 1 ⁄2 — — 100 32GU††92B1H2* 32GU††92W1H2* 32GU††92F1H2* 32GU††92N1H2*<br />

20 25 40 40 3 — — — 100 32HU††92B1H2* 32HU††92W1H2* 32HU††92F1H2* 32HU††92N1H2*<br />

25 30 50 50 — 3 1 ⁄2 — — 200 32IU††92B1H2* 32IU††92W1H2* 32IU††92F1H2* 32IU††92N1H2*<br />

30 40 75 75 4 — — — 200 32JU††92B1H2* 32JU††92W1H2* 32JU††92F1H2* 32JU††92N1H2*<br />

List<br />

Price $<br />

List<br />

Price $<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

a Dual voltage coils not available in modified starters.<br />

First † for high speed, second † for low speed. Use motor<br />

nameplate information to select FLA. If motor FLA<br />

are unknown, select overload on the basis that<br />

low speed FLA will be no greater than 50% of high<br />

speed FLA.<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-31


Combination Two Speed Heavy Duty Starters<br />

MCP Type, Constant or Variable Torque with Solid State Overload, Class 32<br />

Revised on 03/31/20<br />

Selection<br />

Ordering Information<br />

Replace the (*) with a letter from<br />

the coil table. Dual voltage coils are<br />

wired on high voltage unless specified<br />

on order.<br />

Replace the (†) with the letter that<br />

corresponds to the correct low speed<br />

FLA in the FLA table. <br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-149.<br />

Wiring Diagrams see page 17-160.<br />

Replacement Parts see page 17-120.<br />

Coil Table<br />

60Hz Voltage<br />

Letter<br />

24 J<br />

120 F<br />

110–120/220–240 a A<br />

200–208 D<br />

220–240 G<br />

277 L<br />

220–240/440–480 a C<br />

440–480 H<br />

575–600 E<br />

For other voltages and frequencies, see<br />

Factory Modifications page 17-114.<br />

Low Speed FLA Table<br />

OLR<br />

Size FLA Frame Size †<br />

0,1 0.25–1 A A<br />

0,1 0.75–3.4 A B<br />

0,1 3–12 A1 C<br />

0,1 5.5–22 A1 D<br />

0-1 3 /4 10–40 A1 E<br />

2-3 13–52 B F<br />

2-3 25–100 B G<br />

3 1 /2-4 50–200 B H<br />

NEMA & General<br />

Purpose Control<br />

17<br />

One Winding Consequent Pole, 3-Phase (Constant or Variable Torque)<br />

Max Hp<br />

Overload Enclosure<br />

200<br />

Volts<br />

1<br />

⁄2<br />

Motor<br />

Circuit<br />

Interruter<br />

ETI Amps<br />

NEMA 1<br />

General Purpose<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

304 Stainless Steel<br />

NEMA 4X Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

230 460 575 NEMA Half<br />

Amp Frame Catalog List Catalog List Catalog List Catalog<br />

Volts Volts Volts Size Size<br />

Range Size Number Price $ Number Price $ Number Price $ Number<br />

3<br />

⁄4 1 1 ⁄2 2 0 — 3 0.75–3.4 A 32CUB†92B2V* 32CUB†92W2V* 32CUB†92F2V* 32CUB†92N2V*<br />

2 2 5 5 0 — 10 3–12 A1 32CUC†92B2V* 32CUC†92W2V* 32CUC†92F2V* 32CUC†92N2V*<br />

3 3 — — 0 — 25 5.5–22 A1 32CUD†92B2V* 32CUD†92W2V* 32CUD†92F2V* 32CUD†92N2V*<br />

1<br />

⁄2<br />

3<br />

⁄4 1 1 ⁄2 1 1 ⁄2 1 — 3 0.75–3.4 A 32DUB†92B2V* 32DUB†92W2V* 32DUB†92F2V* 32DUB†92N2V*<br />

2 2 5 5 1 — 10 3–12 A1 32DUC†92B2V* 32DUC†92W2V* 32DUC†92F2V* 32DUC†92N2V*<br />

3 3 10 10 1 — 25 5.5–22 A1 32DUD†92B2V* 32DUD†92W2V* 32DUD†92F2V* 32DUD†92N2V*<br />

7 1 ⁄2 7 1 ⁄2 — — 1 — 30 10–40 A1 32DUE†92B2V* 32DUE†92W2V* 32DUE†92F2V* 32DUE†92N2V*<br />

— — 15 15 — 1 3 ⁄4 40 10–40 A1 32EUE†92B2V* 32EUE†92W2V* 32EUE†92F2V* 32EUE†92N2V*<br />

10 15 25 25 2 — 50 13–52 B 32FUF†92B2V* 32FUF†92W2V* 32FUF†92F2V* 32FUF†92N2V*<br />

15 20 30 30 — 2 1 ⁄2 100 25–100 B 32GUG†92B2V* 32GUG†92W2V* 32GUG†92F2V* 32GUG†92N2V*<br />

25 30 50 50 3 — 125 25–100 B 32HUG†92B2V* 32HUG†92W2V* 32HUG†92F2V* 32HUG†92N2V*<br />

30 40 75 75 — 3 1 ⁄2 125 50–200 B 32IUH†92B2V* 32IUH†92W2V* 32IUH†92F2V* 32IUH†92N2V*<br />

40 50 100 100 4 — 150 50–200 B 32JUH†92B2V* 32JUH†92W2V* 32JUH†92F2V* 32JUH†92N2V*<br />

List<br />

Price $<br />

CONTROL<br />

PRODUCTS<br />

Two Separate Windings, 3-Phase (Constant or Variable Torque)<br />

Max Hp<br />

Overload Enclosure<br />

NEMA 1<br />

General Purpose<br />

200<br />

Volts<br />

1<br />

⁄2<br />

Motor<br />

Circuit<br />

Interruter<br />

ETI Amps<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

304 Stainless Steel<br />

NEMA 4X Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

230 460 575 NEMA Half<br />

Amp Frame Catalog List Catalog List Catalog List Catalog<br />

Volts Volts Volts Size Size<br />

Range Size Number Price $ Number Price $ Number Price $ Number<br />

3<br />

⁄4 1 1 ⁄2 2 0 — 3 0.75–3.4 A 32CUB†92B1V* 32CUB†92W1V* 32CUB†92F1V* 32CUB†92N1V*<br />

2 2 5 5 0 — 10 3–12 A1 32CUC†92B1V* 32CUC†92W1V* 32CUC†92F1V* 32CUC†92N1V*<br />

3 3 — — 0 — 25 5.5–22 A1 32CUD†92B1V* 32CUD†92W1V* 32CUD†92F1V* 32CUD†92N1V*<br />

1<br />

⁄2<br />

3<br />

⁄4 1 1 ⁄2 1 1 ⁄2 1 — 3 0.75–3.4 A 32DUB†92B1V* 32DUB†92W1V* 32DUB†92F1V* 32DUB†92N1V*<br />

2 2 5 5 1 — 10 3–12 A1 32DUC†92B1V* 32DUC†92W1V* 32DUC†92F1V* 32DUC†92N1V*<br />

3 3 10 10 1 — 25 5.5–22 A1 32DUD†92B1V* 32DUD†92W1V* 32DUD†92F1V* 32DUD†92N1V*<br />

7 1 ⁄2 7 1 ⁄2 — — 1 — 30 10–40 A1 32DUE†92B1V* 32DUE†92W1V* 32DUE†92F1V* 32DUE†92N1V*<br />

— — 15 15 — 1 3 ⁄4 40 10–40 A1 32EUE†92B1V* 32EUE†92W1V* 32EUE†92F1V* 32EUE†92N1V*<br />

10 15 25 25 2 — 50 13–52 B 32FUF†92B1V* 32FUF†92W1V* 32FUF†92F1V* 32FUF†92N1V*<br />

15 20 30 30 — 2 1 ⁄2 100 25–100 B 32GUG†92B1V* 32GUG†92W1V* 32GUG†92F1V* 32GUG†92N1V*<br />

25 30 50 50 3 — 125 25–100 B 32HUG†92B1V* 32HUG†92W1V* 32HUG†92F1V* 32HUG†92N1V*<br />

30 40 75 75 — 3 1 ⁄2 125 50–200 B 32IUH†92B1V* 32IUH†92W1V* 32IUH†92F1V* 32IUH†92N1V*<br />

40 50 100 100 4 — 150 50–200 B 32JUH†92B1V* 32JUH†92W1V* 32JUH†92F1V* 32JUH†92N1V*<br />

List<br />

Price $<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

a Dual voltage coils not available in modified starters.<br />

If motor FLA are unknown, select overload on the<br />

basis that low speed FLA will be no greater than 50%<br />

of high speed FLA.<br />

17-32<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Combination Two Speed Heavy Duty Starters<br />

MCP Type, Constant Horsepower with Solid State Overload, Class 32<br />

Revised on 03/31/20<br />

Selection<br />

Ordering Information<br />

Replace the (*) with a letter from<br />

the coil table. Dual voltage coils are<br />

wired on high voltage unless specified<br />

on order.<br />

Replace the (†) with the letter that<br />

corresponds to the correct FLA in the<br />

High/Low Speed FLA table. <br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-149.<br />

Wiring Diagrams see page 17-160.<br />

Replacement Parts see page 17-120.<br />

Coil Table<br />

60Hz Voltage Letter<br />

24 J<br />

120 F<br />

110–120/220–240 a A<br />

200–208 D<br />

220–240 G<br />

277 L<br />

220–240/440–480 a C<br />

440–480 H<br />

575–600 E<br />

For other voltages and<br />

frequencies see Factory<br />

Modifications page 17-114.<br />

High/Low Speed FLA Table <br />

OLR<br />

Size FLA Frame Size †<br />

0,1 0.25–1 A A<br />

0,1 0.75–3.4 A B<br />

0,1 3–12 A1 C<br />

0,1 5.5–22 A1 D<br />

0-1 3 /4 10–40 A1 E<br />

2-3 13–52 B F<br />

2-3 25–100 B G<br />

3 1 /2-4 50–200 B H<br />

* First (†) for high speed, second<br />

(†) for low speed. Use motor nameplate<br />

to select FLA. If motor FLA<br />

are unknown, select overload on<br />

the bases that the low speed FLA<br />

will be no greater than 50 % of high<br />

speed FLA.<br />

One Winding Consequent Pole, 3-Phase (Constant Horsepower)<br />

Max Hp<br />

Overload Enclosure<br />

NEMA 1<br />

General Purpose<br />

200<br />

Volts<br />

Two Separate Windings, 3-Phase (Constant Horsepower)<br />

Max Hp<br />

Overload Enclosure<br />

NEMA 1<br />

General Purpose<br />

200<br />

Volts<br />

230<br />

Volts<br />

230<br />

Volts<br />

460<br />

Volts<br />

460<br />

Volts<br />

575<br />

Volts<br />

575<br />

Volts<br />

NEMA<br />

Size<br />

NEMA<br />

Size<br />

Half<br />

Size<br />

Half<br />

Size<br />

Motor<br />

Circuit<br />

Interruter<br />

ETI Amps<br />

Motor<br />

Circuit<br />

Interruter<br />

ETI Amps<br />

Amp<br />

Range<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

Frame<br />

Size<br />

Catalog<br />

Number<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

304 Stainless Steel<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

304 Stainless Steel<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

NEMA 4X Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

NEMA 4X Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

Catalog<br />

Number<br />

2 2 3 3 0 — 10 — A or A1 32CU††92B1H* 32CU††92W1H* 32CU††92F1H* 32CU††92N1H*<br />

5 5 7 1 ⁄2 7 1 ⁄2 1 — 25 — A or A1 32DU††92B1H* 32DU††92W1H* 32DU††92F1H* 32DU††92N1H*<br />

7 1 ⁄2 7 1 ⁄2 10 10 — 1 3 ⁄4 40 — A1 32EU††92B1H* 32EU††92W1H* 32EU††92F1H* 32EU††92N1H*<br />

7 1 ⁄2 10 20 20 2 — 50 — B 32FU††92B1H* 32FU††92W1H* 32FU††92F1H* 32FU††92N1H*<br />

10 15 25 25 — 2 1 ⁄2 100 — B 32GU††92B1H* 32GU††92W1H* 32GU††92F1H* 32GU††92N1H*<br />

20 25 40 40 3 — 100 — B 32HU††92B1H* 32HU††92W1H* 32HU††92F1H* 32HU††92N1H*<br />

25 30 50 50 — 3 1 ⁄2 125 — B 32IU††92B1H* 32IU††92W1H* 32IU††92F1H* 32IU††92N1H*<br />

30 40 75 75 4 — 150 — B 32JU††92B1H* 32JU††92W1H* 32JU††92F1H* 32JU††92N1H*<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

2 2 3 3 0 — 10 — A or A1 32CU††92B2H* 32CU††92W2H* 32CU††92F2H* 32CU††92N2H*<br />

5 5 7 1 ⁄2 7 1 ⁄2 1 — 25 — A or A1 32DU††92B2H* 32DU††92W2H* 32DU††92F2H* 32DU††92N2H*<br />

7 1 ⁄2 7 1 ⁄2 10 10 — 1 3 ⁄4 40 — A1 32EU††92B2H* 32EU††92W2H* 32EU††92F2H* 32EU††92N2H*<br />

7 1 ⁄2 10 20 20 2 — 50 — B 32FU††92B2H* 32FU††92W2H* 32FU††92F2H* 32FU††92N2H*<br />

10 15 25 25 — 2 1 ⁄2 100 — B 32GU††92B2H* 32GU††92W2H* 32GU††92F2H* 32GU††92N2H*<br />

20 25 40 40 3 — 100 — B 32HU††92B2H* 32HU††92W2H* 32HU††92F2H* 32HU††92N2H*<br />

25 30 50 50 — 3 1 ⁄2 125 — B 32IU††92B2H* 32IU††92W2H* 32IU††92F2H* 32IU††92N2H*<br />

30 40 75 75 4 — 150 — B 32JU††92B2H* 32JU††92W2H* 32JU††92F2H* 32JU††92N2H*<br />

List<br />

Price $<br />

List<br />

Price $<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

a Dual voltage coils not available in modified starters.<br />

First † for high speed, second † for low speed. Use motor<br />

nameplate information to select FLA. If motor FLA<br />

are unknown, select overload on the basis that<br />

low speed FLA will be no greater than 50% of high<br />

speed FLA.<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-33


Reduced Voltage Heavy Duty Starters<br />

Features and Benefits<br />

Revised on 03/31/20<br />

General<br />

Siemens manufactures the three commonly<br />

used electromechanical reduced<br />

voltage starters. Each one is designed<br />

for specific application requirements<br />

and consists of auto transformer,<br />

wye-delta and partwinding starters.<br />

The reduced voltage starter:<br />

b Reduces inrush current<br />

b Provides smoother acceleration of the<br />

load<br />

b Reduces starting torque<br />

b Reduces stresses on mechanical<br />

linkages<br />

Combination and non-combination<br />

reduced voltage starter sizes range<br />

from 0 to 6 including Siemens exclusive<br />

motormatched half-sizes. Enclosure<br />

types include 1, 3R/12, 4 painted and<br />

4/4X stainless steel. UL listed file<br />

#E14900 (class 36); file #E185287<br />

(class 37). CSA certified file #LR 6535<br />

(class 36 & 37).<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Auto Transformer Starter<br />

b Maximum torque per amp<br />

b Three coil auto transformer for balanced<br />

starting currents<br />

b 50, 65 and 80% voltage taps<br />

b Closed circuit transition<br />

b Adjustable starting time<br />

b Solid-state OLR overload as standard<br />

b CPT supplied as standard<br />

b Wide range of factory modifications<br />

Wye-Delta Starter<br />

b Lowest starting torque<br />

b Closed or open circuit transition<br />

b Adjustable starting time<br />

b Solid-state OLR overload as standard<br />

b CPT supplied as standard<br />

b Wide range of factory modifications<br />

Various Methods of Electro-Mechanical Reduced Voltage Motor Starting<br />

—A General Comparison<br />

Part-Winding Starter<br />

b Simplest design – most economical<br />

b Adjustable starting time<br />

b Solid-state OLR overload as standard<br />

b CPT supplied as standard<br />

b Wide range of factory modifications<br />

Autotransformer Part-Winding Wye-Delta<br />

50% 65% 80%<br />

Characteristic Tap Tap Tap 2 step<br />

Starting current drawn from<br />

line as % of that which would 25% 42% 64% 65% 33%<br />

be drawn upon full voltage<br />

starting<br />

Starting current drawn by the<br />

motor<br />

50% 65% 80% 65% 58%<br />

Starting torque developed as<br />

25% 42% 64% 40% 33%<br />

% of that which would be<br />

Increases slightly<br />

developed on full voltage<br />

with speed<br />

starting<br />

Smoothness of acceleration First in order of Third in order of Second in order of<br />

Smoothness Smoothness Smoothness<br />

Allowable accelerating times 15 seconds at 200HP<br />

(typical) max. or 30 seconds on 5 seconds max. 5-60 seconds<br />

200HP based on Limited by motor Limited by motor<br />

NEMA medium duty design design<br />

transformers<br />

Starting current and torque Adjustable within limits<br />

and adjustments<br />

of various taps<br />

Fixed<br />

Fixed<br />

17-34<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Reduced Voltage Heavy Duty Starters<br />

Auto Transformer with Solid State Overload, Class 36 & 37<br />

Ordering Information<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-150.<br />

Wiring Diagrams see page 17-163.<br />

Replacement Parts see page 17-120.<br />

Coil and Control Voltage<br />

Selection<br />

The coil voltage will always match the<br />

motor voltage. As standard, a CPT is<br />

supplied and 120V control voltage is<br />

utilized. To change to 120V voltage<br />

(CPT not supplied), change the 9th<br />

character to “F”. To change to 24VAC<br />

voltage (CPT not supplied), change the<br />

9th character to “J”.<br />

NEMA 1 General Purpose Enclosures<br />

Motor<br />

Voltage<br />

200<br />

230<br />

460<br />

575<br />

Max<br />

Hp<br />

NEMA<br />

Size<br />

(1/2 Size)<br />

Overload Relay<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

Non-Combination<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Combination Non-Fusible<br />

Disconnect Combination Fusible Disconnect Combination Circit Breaker<br />

Disc.<br />

Fuse Clip<br />

Circuit<br />

Amp Catalog List Amp/Volt Catalog List Breaker Catalog List<br />

Rating Number Price $ Rating Number Price $ Amps Number Price $<br />

10 (1¾) 10–40 A1 36EUET6BD 60 37EUET6BDD 60A/250V 37EUET6BDF 50 37EUET6BDP<br />

10 2 13–52 B 36FUFT6BD 60 37FUFT6BDD 60A/250V 37FUFT6BDF 50 37FUFT6BDP<br />

15 (2½) 25–100 B 36GUGT6BD 100 37GUGT6BDD 100A/250V 37GUGT6BDF 100 37GUGT6BDP<br />

25 3 25–100 B 36HUGT6BD 100 37HUGT6BDD 100A/250V 37HUGT6BDF 100 37HUGT6BDP<br />

30 (3½) 50–200 B 36IUHT6BD 200 37IUHT6BDD 200A/250V 37IUHT6BDF 125 37IUHT6BDP<br />

40 4 50–200 B 36JUHT6BD 200 37JUHT6BDD 200A/250V 37JUHT6BDF 150 37JUHT6BDP<br />

50 5 55–250 — — — — — — 250 37LPST6BDP<br />

75 5 55–250 — 36LPUT6BD 400 37LPUT6BDD 400A/250V 37LPUT6BDF 400 37LPUT6BDP<br />

150 6 160–630 — 36MPXT6BD 600 37MPXT6BDD 600A/250V 37MPXT6BDF 600 37MPXT6BDP<br />

10 (1¾) 10–40 A1 36EUET2BG 60 37EUET2BGD 60A/250V 37EUET2BGF 50 37EUET2BGP<br />

15 2 13–52 B 36FUFT2BG 60 37FUFT2BGD 60A/250V 37FUFT2BGF 50 37FUFT2BGP<br />

20 (2½) 25–100 B 36GUGT2BG 100 37GUGT2BGD 100A/250V 37GUGT2BGF 100 37GUGT2BGP<br />

30 3 25–100 B 36HUGT2BG 100 37HUGT2BGD 100A/250V 37HUGT2BGF 100 37HUGT2BGP<br />

40 (3½) 50–200 B 36IUHT2BG 200 37IUHT2BGD 200A/250V 37IUHT2BGF 125 37IUHT2BGP<br />

50 4 50–200 B 36JUHT2BG 200 37JUHT2BGD 200A/250V 37JUHT2BGF 150 37JUHT2BGP<br />

75 5 55–250 — — — — — — 250 37LPST2BGP<br />

100 5 55–250 — 36LPUT2BG 400 37LPUT2BGD 400A/250V 37LPUT2BGF 400 37LPUT2BGP<br />

200 6 160–630 — 36MPXT2BG 600 37MPXT2BGD 600A/250V 37MPXT2BGF 600 37MPXT2BGP<br />

15 (1¾) 10–40 A1 36EUET4BH 60 37EUET4BHD 60A/600V 37EUET4BHF 50 37EUET4BHP<br />

25 2 13–52 B 36FUFT4BH 60 37FUFT4BHD 60A/600V 37FUFT4BHF 50 37FUFT4BHP<br />

30 (2½) 13–52 B 36GUGT4BH 100 37GUGT4BHD 100A/600V 37GUGT4BHF 100 37GUGT4BHP<br />

50 3 25–100 B 36HUGT4BH 100 37HUGT4BHD 100A/600V 37HUGT4BHF 100 37HUGT4BHP<br />

75 (3½) 50–200 B 36IUHT4BH 200 37IUHT4BHD 200A/600V 37IUHT4BHF 125 37IUHT4BHP<br />

100 4 50–200 B 36JUHT4BH 200 37JUHT4BHD 200A/600V 37JUHT4BHF 150 37JUHT4BHP<br />

150 5 55–250 — — — — — — 250 37LPST4BHP<br />

200 5 55–250 — 36LPUT4BH 400 37LPUT4BHD 400A/600V 37LPUT4BHF 400 37LPUT4BHP<br />

400 6 160–630 — 36MPXT4BH 600 37MPXT4BHD 600A/600V 37MPXT4BHF 600 37MPXT4BHP<br />

15 (1¾) 10–40 A1 36EUET5BE 60 37EUET5BED 60A/600V 37EUET5BEF 50 37EUET5BEP<br />

25 2 13–52 B 36FUFT5BE 60 37FUFT5BED 60A/600V 37FUFT5BEF 50 37FUFT5BEP<br />

30 (2½) 13–52 B 36GUGT5BE 100 37GUGT5BED 100A/600V 37GUGT5BEF 100 37GUGT5BEP<br />

50 3 25–100 B 36HUGT5BE 100 37HUGT5BED 100A/600V 37HUGT5BEF 100 37HUGT5BEP<br />

75 (3½) 50–200 B 36IUHT5BE 200 37IUHT5BED 200A/600V 37IUHT5BEF 125 37IUHT5BEP<br />

100 4 50–200 B 36JUHT5BE 200 37JUHT5BED 200A/600V 37JUHT5BEF 150 37JUHT5BEP<br />

150 5 55–250 — — — — — — 250 37LPST5BEP<br />

200 5 55–250 — 36LPUT5BE 400 37LPUT5BED 400A/600V 37LPUT5BEF 400 37LPUT5BEP<br />

400 6 160–630 — 36MPXT5BE 600 37MPXT5BED 600A/600V 37MPXT5BEF 600 37MPXT5BEP<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-35


Reduced Voltage Heavy Duty Starters<br />

Auto Transformer with Solid State Overload, Class 36 & 37<br />

Ordering Information<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-150.<br />

Wiring Diagrams see page 17-163.<br />

Replacement Parts see page 17-120.<br />

Coil and Control Voltage<br />

Selection<br />

The coil voltage will always match the<br />

motor voltage. As standard, a CPT is<br />

supplied and 120V control voltage is<br />

utilized. To change to 120V voltage (CPT<br />

not supplied), change the 9th character<br />

to “F”. To change to 24VAC voltage<br />

(CPT not supplied), change the 9th<br />

character to “J”.<br />

NEMA 4 Painted Enclosures<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Motor<br />

Voltage<br />

200<br />

230<br />

460<br />

575<br />

Max<br />

Hp<br />

NEMA<br />

Size<br />

(1/2 Size)<br />

Overload Relay<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

Non-Combination<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Combination Non-Fusible<br />

Disconnect Combination Fusible Disconnect Combination Circit Breaker<br />

Disc.<br />

Fuse Clip<br />

Circuit<br />

Amp Catalog List Amp/Volt Catalog List Breaker Catalog List<br />

Rating Number Price $ Rating Number Price $ Amps Number Price $<br />

10 (1¾) 10–40 A1 36EUET6ED 60 37EUET6EDD 60A/250V 37EUET6EDF 50 37EUET6EDP<br />

10 2 13–52 B 36FUFT6ED 60 37FUFT6EDD 60A/250V 37FUFT6EDF 50 37FUFT6EDP<br />

15 (2½) 25–100 B 36GUGT6ED 100 37GUGT6EDD 100A/250V 37GUGT6EDF 100 37GUGT6EDP<br />

25 3 25–100 B 36HUGT6ED 100 37HUGT6EDD 100A/250V 37HUGT6EDF 100 37HUGT6EDP<br />

30 (3½) 50–200 B 36IUHT6ED 200 37IUHT6EDD 200A/250V 37IUHT6EDF 125 37IUHT6EDP<br />

40 4 50–200 B 36JUHT6ED 200 37JUHT6EDD 200A/250V 37JUHT6EDF 150 37JUHT6EDP<br />

50 5 55–250 — — — — — — 250 37LPST6EDP<br />

75 5 55–250 — 36LPUT6ED 400 37LPUT6EDD 400A/250V 37LPUT6EDF 400 37LPUT6EDP<br />

150 6 160–630 — 36MPXT6ED 600 37MPXT6EDD 600A/250V 37MPXT6EDF 600 37MPXT6EDP<br />

10 (1¾) 10–40 A1 36EUET2EG 60 37EUET2EGD 60A/250V 37EUET2EGF 50 37EUET2EGP<br />

15 2 13–52 B 36FUFT2EG 60 37FUFT2EGD 60A/250V 37FUFT2EGF 50 37FUFT2EGP<br />

20 (2½) 25–100 B 36GUGT2EG 100 37GUGT2EGD 100A/250V 37GUGT2EGF 100 37GUGT2EGP<br />

30 3 25–100 B 36HUGT2EG 100 37HUGT2EGD 100A/250V 37HUGT2EGF 100 37HUGT2EGP<br />

40 (3½) 50–200 B 36IUHT2EG 200 37IUHT2EGD 200A/250V 37IUHT2EGF 125 37IUHT2EGP<br />

50 4 50–200 B 36JUHT2EG 200 37JUHT2EGD 200A/250V 37JUHT2EGF 150 37JUHT2EGP<br />

75 5 55–250 — — — — — — 250 37LPST2EGP<br />

100 5 55–250 — 36LPUT2EG 400 37LPUT2EGD 400A/250V 37LPUT2EGF 400 37LPUT2EGP<br />

200 6 160–630 — 36MPXT2EG 600 37MPXT2EGD 600A/250V 37MPXT2EGF 600 37MPXT2EGP<br />

15 (1¾) 10–40 A1 36EUET4EH 60 37EUET4EHD 60A/600V 37EUET4EHF 50 37EUET4EHP<br />

25 2 13–52 B 36FUFT4EH 60 37FUFT4EHD 60A/600V 37FUFT4EHF 50 37FUFT4EHP<br />

30 (2½) 13–52 B 36GUGT4EH 100 37GUGT4EHD 100A/600V 37GUGT4EHF 100 37GUGT4EHP<br />

50 3 25–100 B 36HUGT4EH 100 37HUGT4EHD 100A/600V 37HUGT4EHF 100 37HUGT4EHP<br />

75 (3½) 50–200 B 36IUHT4EH 200 37IUHT4EHD 200A/600V 37IUHT4EHF 125 37IUHT4EHP<br />

100 4 50–200 B 36JUHT4EH 200 37JUHT4EHD 200A/600V 37JUHT4EHF 150 37JUHT4EHP<br />

150 5 55–250 — — — — — — 250 37LPST4EHP<br />

200 5 55–250 — 36LPUT4EH 400 37LPUT4EHD 400A/600V 37LPUT4EHF 400 37LPUT4EHP<br />

400 6 160–630 — 36MPXT4EH 600 37MPXT4EHD 600A/600V 37MPXT4EHF 600 37MPXT4EHP<br />

15 (1¾) 10–40 A1 36EUET5EE 60 37EUET5EED 60A/600V 37EUET5EEF 50 37EUET5EEP<br />

25 2 13–52 B 36FUFT5EE 60 37FUFT5EED 60A/600V 37FUFT5EEF 50 37FUFT5EEP<br />

30 (2½) 13–52 B 36GUGT5EE 100 37GUGT5EED 100A/600V 37GUGT5EEF 100 37GUGT5EEP<br />

50 3 25–100 B 36HUGT5EE 100 37HUGT5EED 100A/600V 37HUGT5EEF 100 37HUGT5EEP<br />

75 (3½) 50–200 B 36IUHT5EE 200 37IUHT5EED 200A/600V 37IUHT5EEF 125 37IUHT5EEP<br />

100 4 50–200 B 36JUHT5EE 200 37JUHT5EED 200A/600V 37JUHT5EEF 150 37JUHT5EEP<br />

150 5 55–250 — — — — — — 250 37LPST5EEP<br />

200 5 55–250 — 36LPUT5EE 400 37LPUT5EED 400A/600V 37LPUT5EEF 400 37LPUT5EEP<br />

400 6 160–630 — 36MPXT5EE 600 37MPXT5EED 600A/600V 37MPXT5EEF 600 37MPXT5EEP<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

17-36<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Reduced Voltage Heavy Duty Starters<br />

Auto Transformer with Solid State Overload, Class 36 & 37<br />

Ordering Information<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-150.<br />

Wiring Diagrams see page 17-163.<br />

Replacement Parts see page 17-120.<br />

Coil and Control Voltage<br />

Selection<br />

The coil voltage will always match the<br />

motor voltage. As standard, a CPT is<br />

supplied and 120V control voltage is<br />

utilized. To change to 120V voltage (CPT<br />

not supplied), change the 9th character<br />

to “F”. To change to 24VAC voltage<br />

(CPT not supplied), change the 9th<br />

character to “J”.<br />

NEMA 4/4X Stainless Steel Enclosures<br />

Motor<br />

Voltage<br />

200<br />

230<br />

460<br />

575<br />

Max<br />

Hp<br />

NEMA<br />

Size<br />

(1/2 Size)<br />

Overload Relay<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

Non-Combination<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Combination Non-Fusible<br />

Disconnect Combination Fusible Disconnect Combination Circit Breaker<br />

Disc.<br />

Fuse Clip<br />

Circuit<br />

Amp Catalog List Amp/Volt Catalog List Breaker Catalog List<br />

Rating Number Price $ Rating Number Price $ Amps Number Price $<br />

10 (1¾) 10–40 A1 36EUET6WD 60 37EUET6WDD 60A/250V 37EUET6WDF 50 37EUET6WDP<br />

10 2 13–52 B 36FUFT6WD 60 37FUFT6WDD 60A/250V 37FUFT6WDF 50 37FUFT6WDP<br />

15 (2½) 25–100 B 36GUGT6WD 100 37GUGT6WDD 100A/250V 37GUGT6WDF 100 37GUGT6WDP<br />

25 3 25–100 B 36HUGT6WD 100 37HUGT6WDD 100A/250V 37HUGT6WDF 100 37HUGT6WDP<br />

30 (3½) 50–200 B 36IUHT6WD 200 37IUHT6WDD 200A/250V 37IUHT6WDF 125 37IUHT6WDP<br />

40 4 50–200 B 36JUHT6WD 200 37JUHT6WDD 200A/250V 37JUHT6WDF 150 37JUHT6WDP<br />

10 (1¾) 10–40 A1 36EUET2WG 60 37EUET2WGD 60A/250V 37EUET2WGF 50 37EUET2WGP<br />

15 2 13–52 B 36FUFT2WG 60 37FUFT2WGD 60A/250V 37FUFT2WGF 50 37FUFT2WGP<br />

20 (2½) 25–100 B 36GUGT2WG 100 37GUGT2WGD 100A/250V 37GUGT2WGF 100 37GUGT2WGP<br />

30 3 25–100 B 36HUGT2WG 100 37HUGT2WGD 100A/250V 37HUGT2WGF 100 37HUGT2WGP<br />

40 (3½) 50–200 B 36IUHT2WG 200 37IUHT2WGD 200A/250V 37IUHT2WGF 125 37IUHT2WGP<br />

50 4 50–200 B 36JUHT2WG 200 37JUHT2WGD 200A/250V 37JUHT2WGF 150 37JUHT2WGP<br />

15 (1¾) 10–40 A1 36EUET4WH 60 37EUET4WHD 60A/600V 37EUET4WHF 50 37EUET4WHP<br />

25 2 13–52 B 36FUFT4WH 60 37FUFT4WHD 60A/600V 37FUFT4WHF 50 37FUFT4WHP<br />

30 (2½) 13–52 B 36GUGT4WH 100 37GUGT4WHD 100A/600V 37GUGT4WHF 100 37GUGT4WHP<br />

50 3 25–100 B 36HUGT4WH 100 37HUGT4WHD 100A/600V 37HUGT4WHF 100 37HUGT4WHP<br />

75 (3½) 50–200 B 36IUHT4WH 200 37IUHT4WHD 200A/600V 37IUHT4WHF 125 37IUHT4WHP<br />

100 4 50–200 B 36JUHT4WH 200 37JUHT4WHD 200A/600V 37JUHT4WHF 150 37JUHT4WHP<br />

15 (1¾) 10–40 A1 36EUET5WE 60 37EUET5WED 60A/600V 37EUET5WEF 50 37EUET5WEP<br />

25 2 13–52 B 36FUFT5WE 60 37FUFT5WED 60A/600V 37FUFT5WEF 50 37FUFT5WEP<br />

30 (2½) 13–52 B 36GUGT5WE 100 37GUGT5WED 100A/600V 37GUGT5WEF 100 37GUGT5WEP<br />

50 3 25–100 B 36HUGT5WE 100 37HUGT5WED 100A/600V 37HUGT5WEF 100 37HUGT5WEP<br />

75 (3½) 50–200 B 36IUHT5WE 200 37IUHT5WED 200A/600V 37IUHT5WEF 125 37IUHT5WEP<br />

100 4 50–200 B 36JUHT5WE 200 37JUHT5WED 200A/600V 37JUHT5WEF 150 37JUHT5WEP<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-37


Reduced Voltage Heavy Duty Starters<br />

Auto Transformer with Solid State Overload, Class 36 & 37<br />

Ordering Information<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-150.<br />

Wiring Diagrams see page 17-163.<br />

Replacement Parts see page 17-120.<br />

Revised on 08/31/18<br />

Coil and Control Voltage<br />

Selection<br />

The coil voltage will always match the<br />

motor voltage. As standard, a CPT is<br />

supplied and 120V control voltage is<br />

utilized. To change to 120V voltage (CPT<br />

not supplied), change the 9th character<br />

to “F”. To change to 24VAC voltage<br />

(CPT not supplied), change the 9th<br />

character to “J”.<br />

NEMA 12, NEMA 3/3R<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Motor<br />

Voltage<br />

200<br />

230<br />

460<br />

575<br />

Max<br />

Hp<br />

NEMA<br />

Size<br />

(1/2 Size)<br />

Overload Relay<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

Non-Combination<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Combination Non-Fusible<br />

Disconnect Combination Fusible Disconnect Combination Circit Breaker<br />

Disc.<br />

Fuse Clip<br />

Circuit<br />

Amp Catalog List Amp/Volt Catalog List Breaker Catalog List<br />

Rating Number Price $ Rating Number Price $ Amps Number Price $<br />

10 (1¾) 10–40 A1 36EUET6ND 60 37EUET6NDD 60A/250V 37EUET6NDF 50 37EUET6NDP<br />

10 2 13–52 B 36FUFT6ND 60 37FUFT6NDD 60A/250V 37FUFT6NDF 50 37FUFT6NDP<br />

15 (2½) 25–100 B 36GUGT6ND 100 37GUGT6NDD 100A/250V 37GUGT6NDF 100 37GUGT6NDP<br />

25 3 25–100 B 36HUGT6ND 100 37HUGT6NDD 100A/250V 37HUGT6NDF 100 37HUGT6NDP<br />

30 (3½) 50–200 B 36IUHT6ND 200 37IUHT6NDD 200A/250V 37IUHT6NDF 125 37IUHT6NDP<br />

40 4 50–200 B 36JUHT6ND 200 37JUHT6NDD 200A/250V 37JUHT6NDF 150 37JUHT6NDP<br />

50 5 55–250 — — — — — — 250 37LPST6NDP<br />

75 5 55–250 — 36LPUT6ND 400 37LPUT6NDD 400A/250V 37LPUT6NDF 400 37LPUT6NDP<br />

150 6 160–630 — 36MPXT6ND 600 37MPXT6NDD 600A/250V 37MPXT6NDF 600 37MPXT6NDP<br />

10 (1¾) 10–40 A1 36EUET2NG 60 37EUET2NGD 60A/250V 37EUET2NGF 50 37EUET2NGP<br />

15 2 13–52 B 36FUFT2NG 60 37FUFT2NGD 60A/250V 37FUFT2NGF 50 37FUFT2NGP<br />

20 (2½) 25–100 B 36GUGT2NG 100 37GUGT2NGD 100A/250V 37GUGT2NGF 100 37GUGT2NGP<br />

30 3 25–100 B 36HUGT2NG 100 37HUGT2NGD 100A/250V 37HUGT2NGF 100 37HUGT2NGP<br />

40 (3½) 50–200 B 36IUHT2NG 200 37IUHT2NGD 200A/250V 37IUHT2NGF 125 37IUHT2NGP<br />

50 4 50–200 B 36JUHT2NG 200 37JUHT2NGD 200A/250V 37JUHT2NGF 150 37JUHT2NGP<br />

75 5 55–250 — — — — — — 250 37LPST2NGP<br />

100 5 55–250 — 36LPUT2NG 400 37LPUT2NGD 400A/250V 37LPUT2NGF 400 37LPUT2NGP<br />

200 6 160–630 — 36MPXT2NG 600 37MPXT2NGD 600A/250V 37MPXT2NGF 600 37MPXT2NGP<br />

15 (1¾) 10–40 A1 36EUET4NH 60 37EUET4NHD 60A/600V 37EUET4NHF 50 37EUET4NHP<br />

25 2 13–52 B 36FUFT4NH 60 37FUFT4NHD 60A/600V 37FUFT4NHF 50 37FUFT4NHP<br />

30 (2½) 13–52 B 36GUGT4NH 100 37GUGT4NHD 100A/600V 37GUGT4NHF 100 37GUGT4NHP<br />

50 3 25–100 B 36HUGT4NH 100 37HUGT4NHD 100A/600V 37HUGT4NHF 100 37HUGT4NHP<br />

75 (3½) 50–200 B 36IUHT4NH 200 37IUHT4NHD 200A/600V 37IUHT4NHF 125 37IUHT4NHP<br />

100 4 50–200 B 36JUHT4NH 200 37JUHT4NHD 200A/600V 37JUHT4NHF 150 37JUHT4NHP<br />

150 5 55–250 — — — — — — 250 37LPST4NHP<br />

200 5 55–250 — 36LPUT4NH 400 37LPUT4NHD 400A/600V 37LPUT4NHF 400 37LPUT4NHP<br />

400 6 160–630 — 36MPXT4NH 600 37MPXT4NHD 600A/600V 37MPXT4NHF 600 37MPXT4NHP<br />

15 (1¾) 10–40 A1 36EUET5NE 60 37EUET5NED 60A/600V 37EUET5NEF 50 37EUET5NEP<br />

25 2 13–52 B 36FUFT5NE 60 37FUFT5NED 60A/600V 37FUFT5NEF 50 37FUFT5NEP<br />

30 (2½) 13–52 B 36GUGT5NE 100 37GUGT5NED 100A/600V 37GUGT5NEF 100 37GUGT5NEP<br />

50 3 25–100 B 36HUGT5NE 100 37HUGT5NED 100A/600V 37HUGT5NEF 100 37HUGT5NEP<br />

75 (3½) 50–200 B 36IUHT5NE 200 37IUHT5NED 200A/600V 37IUHT5NEF 125 37IUHT5NEP<br />

100 4 50–200 B 36JUHT5NE 200 37JUHT5NED 200A/600V 37JUHT5NEF 150 37JUHT5NEP<br />

150 5 55–250 — — — — — — 250 37LPST5NEP<br />

200 5 55–250 — 36LPUT5NE 400 37LPUT5NED 400A/600V 37LPUT5NEF 400 37LPUT5NEP<br />

400 6 160–630 — 36MPXT5NE 600 37MPXT5NED 600A/600V 37MPXT5NEF 600 37MPXT5NEP<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

17-38<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Reduced Voltage Heavy Duty Starters<br />

Revised on 03/31/20<br />

2 Step Part Winding with Solid State Overload, Class 36 & 37 Selection<br />

Ordering Information<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page page 17-150.<br />

Wiring Diagrams see page 17-162.<br />

Replacement Parts see page 17-120.<br />

Coil and Control Voltage<br />

The coil voltage will always match the<br />

motor voltage. As standard, a CPT is<br />

supplied and 120V control voltage is<br />

utilized. To change to 120V voltage (CPT<br />

not supplied), change the 9th character<br />

to “F”. To change to 24VAC voltage<br />

(CPT not supplied), change the 9th<br />

character to “J”.<br />

NEMA 1 General Purpose Enclosures<br />

Motor<br />

Voltage<br />

200<br />

230<br />

460<br />

575<br />

Max<br />

Hp<br />

Overload Relay<br />

NEMA<br />

Size Amp<br />

(1/2 Size) Range<br />

Frame<br />

Size<br />

Non-Combination<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Combination Non-Fusible<br />

Disconnect Combination Fusible Disconnect Combination Circit Breaker<br />

Disc.<br />

Fuse Clip<br />

Circuit<br />

Amp Catalog List Amp/Volt Catalog List Breaker Catalog List<br />

Rating Number Price $ Rating Number Price $ Amps Number Price $<br />

7 1 ⁄2 0 5.5–22 A1 36CUDP6BD 60 37CUDP6BDD 60A/250V 37CUDP6BDF 30 37CUDP6BDP<br />

10 1 5.5–22 A1 36DUDP6BD 60 37DUDP6BDD 60A/250V 37DUDP6BDF 50 37DUDP6BDP<br />

15 (1¾) 10–40 A1 36EUEP6BD 100 37EUEP6BDD 100A/250V 37EUEP6BDF 100 37EUEP6BDP<br />

20 2 13–52 B 36FUFP6BD 100 37FUFP6BDD 100A/250V 37FUFP6BDF 100 37FUFP6BDP<br />

30 (2½) 25–100 B 36GUGP6BD 200 37GUGP6BDD 200A/250V 37GUGP6BDF 125 37GUGP6BDP<br />

40 3 25–100 B 36HUGP6BD 200 37HUGP6BDD 200A/250V 37HUGP6BDF 150 37HUGP6BDP<br />

50 (3½) 50–200 B 36IUHP6BD 200 37IUHP6BDD 200A/250V 37IUHP6BDF 250 37IUHP6BDP<br />

75 4 50–200 B 36JUHP6BD 400 37JUHP6BDD 400A/250V 37JUHP6BDF 400 37JUHP6BDP<br />

100 5 55–250 — — — — — — 600 37LPSP6BDP<br />

150 5 55–250 — 36LPUP6BD 600 37LPUP6BDD 600A/250V 37LPUP6BDF 600 37LPUP6BDP<br />

7 1 ⁄2 0 5.5–22 A1 36CUDP2BG 60 37CUDP2BGD 60A/250V 37CUDP2BGF 30 37CUDP2BGP<br />

10 1 5.5–22 A1 36DUDP2BG 60 37DUDP2BGD 60A/250V 37DUDP2BGF 50 37DUDP2BGP<br />

20 (1½) 10–40 A1 36EUEP2BG 100 37EUEP2BGD 100A/250V 37EUEP2BGF 100 37EUEP2BGP<br />

25 2 13–52 B 36FUFP2BG 100 37FUFP2BGD 100A/250V 37FUFP2BGF 100 37FUFP2BGP<br />

30 (2½) 25–100 B 36GUGP2BG 200 37GUGP2BGD 200A/250V 37GUGP2BGF 100 37GUGP2BGP<br />

50 3 25–100 B 36HUGP2BG 200 37HUGP2BGD 200A/250V 37HUGP2BGF 150 37HUGP2BGP<br />

60 (3½) 50–200 B 36IUHP2BG 200 37IUHP2BGD 200A/250V 37IUHP2BGF 250 37IUHP2BGP<br />

75 4 50–200 B 36JUHP2BG 400 37JUHP2BGD 400A/250V 37JUHP2BGF 250 37JUHP2BGP<br />

125 5 55–250 — — — — — — 400 37LPSP2BGP<br />

150 5 55–250 — 36LPUP2BG 600 37LPUP2BGD 600A/250V 37LPUP2BGF 600 37LPUP2BGP<br />

300 6 160–630 — 36MPXP2BG 1200 37MPXP2BGD 1200A/250V 37MPXP2BGF 1200 37MPXP2BGP<br />

10 0 5.5–22 A1 36CUDP4BH 30 37CUDP4BHD 30A/600V 37CUDP4BHF 30 37CUDP4BHP<br />

15 1 5.5–22 A1 36DUDP4BH 60 37DUDP4BHD 60A/600V 37DUDP4BHF 30 37DUDP4BHP<br />

30 (1¾) 10–40 A1 36EUEP4BH 60 37EUEP4BHD 60A/600V 37EUEP4BHF 50 37EUEP4BHP<br />

40 2 13–52 B 36FUFP4BH 100 37FUFP4BHD 100A/600V 37FUFP4BHF 100 37FUFP4BHP<br />

60 (2½) 25–100 B 36GUGP4BH 200 37GUGP4BHD 200A/600V 37GUGP4BHF 100 37GUGP4BHP<br />

75 3 25–100 B 36HUGP4BH 200 37HUGP4BHD 200A/600V 37HUGP4BHF 125 37HUGP4BHP<br />

100 (3½) 50–200 B 36IUHP4BH 200 37IUHP4BHD 200A/600V 37IUHP4BHF 150 37IUHP4BHP<br />

150 4 50–200 B 36JUHP4BH 400 37JUHP4BHD 400A/600V 37JUHP4BHF 250 37JUHP4BHP<br />

250 5 55–250 — — — — — — 400 37LPSP4BHP<br />

350 5 55–250 — 36LPUP4BH 600 37LPUP4BHD 600A/600V 37LPUP4BHF 600 37LPUP4BHP<br />

600 6 160–630 — 36MPXP4BH 1200 37MPXP4BHD 1200A/600V 37MPXP4BHF 1200 37MPXP4BHP<br />

10 0 5.5–22 A1 36CUDP5BE 30 37CUDP5BED 30A/600V 37CUDP5BEF 30 37CUDP5BEP<br />

15 1 5.5–22 A1 36DUDP5BE 60 37DUDP5BED 60A/600V 37DUDP5BEF 30 37DUDP5BEP<br />

30 (1¾) 10–40 A1 36EUEP5BE 60 37EUEP5BED 60A/600V 37EUEP5BEF 50 37EUEP5BEP<br />

40 2 13–52 B 36FUFP5BE 60 37FUFP5BED 60A/600V 37FUFP5BEF 50 37FUFP5BEP<br />

60 (2½) 25–100 B 36GUGP5BE 100 37GUGP5BED 100A/600V 37GUGP5BEF 100 37GUGP5BEP<br />

75 3 25–100 B 36HUGP5BE 200 37HUGP5BED 200A/600V 37HUGP5BEF 125 37HUGP5BEP<br />

100 (3½) 50–200 B 36IUHP5BE 400 37IUHP5BED 400A/600V 37IUHP5BEF 150 37IUHP5BEP<br />

150 4 50–200 B 36JUHP5BE 400 37JUHP5BED 400A/600V 37JUHP5BEF 250 37JUHP5BEP<br />

250 5 55–250 — — — — 400A/600V 37LPSP5BEF — —<br />

350 5 55–250 — 36LPUP5BE 600 37LPUP5BED 600A/600V 37LPUP5BEF 400 37LPUP5BEP<br />

600 6 160–630 — 36MPXP5BE 1200 37MPXP5BED 1200A/600V 37MPXP5BEF 1200 37MPXP5BEP<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-39


Reduced Voltage Heavy Duty Starters<br />

2 Step Part Winding with Solid State Overload, Class 36 & 37 Selection<br />

Ordering Information<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page page 17-150.<br />

Wiring Diagrams see page 17-162.<br />

Replacement Parts see page 17-120.<br />

Coil and Control Voltage<br />

The coil voltage will always match the<br />

motor voltage. As standard, a CPT is<br />

supplied and 120V control voltage is<br />

utilized. To change to 120V voltage (CPT<br />

not supplied), change the 9th character<br />

to “F”. To change to 24VAC voltage<br />

(CPT not supplied), change the 9th<br />

character to “J”.<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

NEMA 4 Painted Enclosures<br />

Motor<br />

Voltage<br />

200<br />

230<br />

460<br />

575<br />

Max<br />

Hp<br />

Overload Relay<br />

NEMA<br />

Size Amp<br />

(1/2 Size) Range<br />

Frame<br />

Size<br />

Non-Combination<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Combination Non-Fusible<br />

Disconnect Combination Fusible Disconnect Combination Circit Breaker<br />

Disc.<br />

Fuse Clip<br />

Circuit<br />

Amp Catalog List Amp/Volt Catalog List Breaker Catalog List<br />

Rating Number Price $ Rating Number Price $ Amps Number Price $<br />

7½ 0 5.5–22 A1 36CUDP6ED 60 37CUDP6EDD 60A/250V 37CUDP6EDF 30 37CUDP6EDP<br />

10 1 5.5–22 A1 36DUDP6ED 60 37DUDP6EDD 60A/250V 37DUDP6EDF 50 37DUDP6EDP<br />

15 (1¾) 10–40 A1 36EUEP6ED 100 37EUEP6EDD 100A/250V 37EUEP6EDF 100 37EUEP6EDP<br />

20 2 13–52 B 36FUFP6ED 100 37FUFP6EDD 100A/250V 37FUFP6EDF 100 37FUFP6EDP<br />

30 (2½) 25–100 B 36GUGP6ED 200 37GUGP6EDD 200A/250V 37GUGP6EDF 125 37GUGP6EDP<br />

40 3 25–100 B 36HUGP6ED 200 37HUGP6EDD 200A/250V 37HUGP6EDF 150 37HUGP6EDP<br />

50 (3½) 50–200 B 36IUHP6ED 200 37IUHP6EDD 200A/250V 37IUHP6EDF 250 37IUHP6EDP<br />

75 4 50–200 B 36JUHP6ED 400 37JUHP6EDD 400A/250V 37JUHP6EDF 400 37JUHP6EDP<br />

100 5 55–250 — — — — — — 600 37LPSP6EDP<br />

150 5 55–250 — 36LPUP6ED 600 37LPUP6EDD 600A/250V 37LPUP6EDF 600 37LPUP6EDP<br />

7½ 0 5.5–22 A1 36CUDP2EG 60 37CUDP2EGD 60A/250V 37CUDP2EGF 30 37CUDP2EGP<br />

10 1 5.5–22 A1 36DUDP2EG 60 37DUDP2EGD 60A/250V 37DUDP2EGF 50 37DUDP2EGP<br />

20 (1½) 10–40 A1 36EUEP2EG 100 37EUEP2EGD 100A/250V 37EUEP2EGF 100 37EUEP2EGP<br />

25 2 13–52 B 36FUFP2EG 100 37FUFP2EGD 100A/250V 37FUFP2EGF 100 37FUFP2EGP<br />

30 (2½) 25–100 B 36GUGP2EG 200 37GUGP2EGD 200A/250V 37GUGP2EGF 100 37GUGP2EGP<br />

50 3 25–100 B 36HUGP2EG 200 37HUGP2EGD 200A/250V 37HUGP2EGF 150 37HUGP2EGP<br />

60 (3½) 50–200 B 36IUHP2EG 200 37IUHP2EGD 200A/250V 37IUHP2EGF 250 37IUHP2EGP<br />

75 4 50–200 B 36JUHP2EG 400 37JUHP2EGD 400A/250V 37JUHP2EGF 250 37JUHP2EGP<br />

125 5 55–250 — — — — — — 400 37LPSP2EGP<br />

150 5 55–250 — 36LPUP2EG 600 37LPUP2EGD 600A/250V 37LPUP2EGF 600 37LPUP2EGP<br />

300 6 160–630 — 36MPXP2EG 1200 37MPXP2EGD 1200A/250V 37MPXP2EGF 1200 37MPXP2EGP<br />

10 0 5.5–22 A1 36CUDP4EH 30 37CUDP4EHD 30A/600V 37CUDP4EHF 30 37CUDP4EHP<br />

15 1 5.5–22 A1 36DUDP4EH 60 37DUDP4EHD 60A/600V 37DUDP4EHF 30 37DUDP4EHP<br />

30 (1¾) 10–40 A1 36EUEP4EH 60 37EUEP4EHD 60A/600V 37EUEP4EHF 50 37EUEP4EHP<br />

40 2 13–52 B 36FUFP4EH 100 37FUFP4EHD 100A/600V 37FUFP4EHF 100 37FUFP4EHP<br />

60 (2½) 25–100 B 36GUGP4EH 200 37GUGP4EHD 200A/600V 37GUGP4EHF 100 37GUGP4EHP<br />

75 3 25–100 B 36HUGP4EH 200 37HUGP4EHD 200A/600V 37HUGP4EHF 125 37HUGP4EHP<br />

100 (3½) 50–200 B 36IUHP4EH 200 37IUHP4EHD 200A/600V 37IUHP4EHF 150 37IUHP4EHP<br />

150 4 50–200 B 36JUHP4EH 400 37JUHP4EHD 400A/600V 37JUHP4EHF 250 37JUHP4EHP<br />

250 5 55–250 — — — — — — 400 37LPSP4EHP<br />

350 5 55–250 — 36LPUP4EH 600 37LPUP4EHD 600A/600V 37LPUP4EHF 600 37LPUP4EHP<br />

600 6 160–630 — 36MPXP4EH 1200 37MPXP4EHD 1200A/600V 37MPXP4EHF 1200 37MPXP4EHP<br />

10 0 5.5–22 A1 36CUDP5EE 30 37CUDP5EED 30A/600V 37CUDP5EEF 30 37CUDP5EEP<br />

15 1 5.5–22 A1 36DUDP5EE 60 37DUDP5EED 60A/600V 37DUDP5EEF 30 37DUDP5EEP<br />

30 (1¾) 10–40 A1 36EUEP5EE 60 37EUEP5EED 60A/600V 37EUEP5EEF 50 37EUEP5EEP<br />

40 2 13–52 B 36FUFP5EE 60 37FUFP5EED 60A/600V 37FUFP5EEF 50 37FUFP5EEP<br />

60 (2½) 25–100 B 36GUGP5EE 100 37GUGP5EED 100A/600V 37GUGP5EEF 100 37GUGP5EEP<br />

75 3 25–100 B 36HUGP5EE 200 37HUGP5EED 200A/600V 37HUGP5EEF 125 37HUGP5EEP<br />

100 (3½) 50–200 B 36IUHP5EE 400 37IUHP5EED 400A/600V 37IUHP5EEF 150 37IUHP5EEP<br />

150 4 50–200 B 36JUHP5EE 400 37JUHP5EED 400A/600V 37JUHP5EEF 250 37JUHP5EEP<br />

250 5 55–250 — — — — 400A/600V 37LPSP5EEF — —<br />

350 5 55–250 — 36LPUP5EE 600 37LPUP5EED 600A/600V 37LPUP5EEF 400 37LPUP5EEP<br />

600 6 160–630 — 36MPXP5EE 1200 37MPXP5EED 1200A/600V 37MPXP5EEF 1200 37MPXP5EEP<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

17-40<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Reduced Voltage Heavy Duty Starters<br />

2 Step Part Winding with Solid State Overload, Class 36 & 37 Selection<br />

Ordering Information<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page page 17-150.<br />

Wiring Diagrams see page 17-162.<br />

Replacement Parts see page 17-120.<br />

Coil and Control Voltage<br />

The coil voltage will always match the<br />

motor voltage. As standard, a CPT is<br />

supplied and 120V control voltage is<br />

utilized. To change to 120V voltage (CPT<br />

not supplied), change the 9th character<br />

to “F”. To change to 24VAC voltage<br />

(CPT not supplied), change the 9th<br />

character to “J”.<br />

NEMA 4/4X Stainless Steel Enclosures<br />

Motor<br />

Voltage<br />

200<br />

230<br />

460<br />

575<br />

Max<br />

Hp<br />

Overload Relay<br />

NEMA<br />

Size Amp<br />

(1/2 Size) Range<br />

Frame<br />

Size<br />

Non-Combination<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Combination Non-Fusible<br />

Disconnect<br />

Disc.<br />

Amp Catalog List<br />

Rating Number Price $<br />

Combination Fusible<br />

Disconnect<br />

Fuse Clip<br />

Amp/Volt Catalog<br />

Rating Number<br />

Combination Circit Breaker<br />

Circuit<br />

Breaker Catalog List<br />

Amps Number Price $<br />

7½ 0 5.5–22 A1 36CUDP6WD 60 37CUDP6WDD 60A/250V 37CUDP6WDF 30 37CUDP6WDP<br />

10 1 5.5–22 A1 36DUDP6WD 60 37DUDP6WDD 60A/250V 37DUDP6WDF 50 37DUDP6WDP<br />

15 (1¾) 10–40 A1 36EUEP6WD 100 37EUEP6WDD 100A/250V 37EUEP6WDF 100 37EUEP6WDP<br />

20 2 13–52 B 36FUFP6WD 100 37FUFP6WDD 100A/250V 37FUFP6WDF 100 37FUFP6WDP<br />

30 (2½) 25–100 B 36GUGP6WD 200 37GUGP6WDD 200A/250V 37GUGP6WDF 125 37GUGP6WDP<br />

40 3 25–100 B 36HUGP6WD 200 37HUGP6WDD 200A/250V 37HUGP6WDF 150 37HUGP6WDP<br />

50 (3½) 50–200 B 36IUHP6WD 200 37IUHP6WDD 200A/250V 37IUHP6WDF 250 37IUHP6WDP<br />

75 4 50–200 B 36JUHP6WD 400 37JUHP6WDD 400A/250V 37JUHP6WDF 400 37JUHP6WDP<br />

7½ 0 5.5–22 A1 36CUDP2WG 60 37CUDP2WGD 60A/250V 37CUDP2WGF 30 37CUDP2WGP<br />

10 1 5.5–22 A1 36DUDP2WG 60 37DUDP2WGD 60A/250V 37DUDP2WGF 50 37DUDP2WGP<br />

20 (1½) 10–40 A1 36EUEP2WG 100 37EUEP2WGD 100A/250V 37EUEP2WGF 100 37EUEP2WGP<br />

25 2 13–52 B 36FUFP2WG 100 37FUFP2WGD 100A/250V 37FUFP2WGF 100 37FUFP2WGP<br />

30 (2½) 25–100 B 36GUGP2WG 200 37GUGP2WGD 200A/250V 37GUGP2WGF 100 37GUGP2WGP<br />

50 3 25–100 B 36HUGP2WG 200 37HUGP2WGD 200A/250V 37HUGP2WGF 150 37HUGP2WGP<br />

60 (3½) 50–200 B 36IUHP2WG 200 37IUHP2WGD 200A/250V 37IUHP2WGF 250 37IUHP2WGP<br />

75 4 50–200 B 36JUHP2WG 400 37JUHP2WGD 400A/250V 37JUHP2WGF 250 37JUHP2WGP<br />

10 0 5.5–22 A1 36CUDP4WH 30 37CUDP4WHD 30A/600V 37CUDP4WHF 30 37CUDP4WHP<br />

15 1 5.5–22 A1 36DUDP4WH 60 37DUDP4WHD 60A/600V 37DUDP4WHF 30 37DUDP4WHP<br />

30 (1¾) 10–40 A1 36EUEP4WH 60 37EUEP4WHD 60A/600V 37EUEP4WHF 50 37EUEP4WHP<br />

40 2 13–52 B 36FUFP4WH 100 37FUFP4WHD 100A/600V 37FUFP4WHF 100 37FUFP4WHP<br />

60 (2½) 25–100 B 36GUGP4WH 200 37GUGP4WHD 200A/600V 37GUGP4WHF 100 37GUGP4WHP<br />

75 3 25–100 B 36HUGP4WH 200 37HUGP4WHD 200A/600V 37HUGP4WHF 125 37HUGP4WHP<br />

100 (3½) 50–200 B 36IUHP4WH 200 37IUHP4WHD 200A/600V 37IUHP4WHF 150 37IUHP4WHP<br />

150 4 50–200 B 36JUHP4WH 400 37JUHP4WHD 400A/600V 37JUHP4WHF 250 37JUHP4WHP<br />

10 0 5.5–22 A1 36CUDP5WE 30 37CUDP5WED 30A/600V 37CUDP5WEF 30 37CUDP5WEP<br />

15 1 5.5–22 A1 36DUDP5WE 60 37DUDP5WED 60A/600V 37DUDP5WEF 30 37DUDP5WEP<br />

30 (1¾) 10–40 A1 36EUEP5WE 60 37EUEP5WED 60A/600V 37EUEP5WEF 50 37EUEP5WEP<br />

40 2 13–52 B 36FUFP5WE 60 37FUFP5WED 60A/600V 37FUFP5WEF 50 37FUFP5WEP<br />

60 (2½) 25–100 B 36GUGP5WE 100 37GUGP5WED 100A/600V 37GUGP5WEF 100 37GUGP5WEP<br />

75 3 25–100 B 36HUGP5WE 200 37HUGP5WED 200A/600V 37HUGP5WEF 125 37HUGP5WEP<br />

100 (3½) 50–200 B 36IUHP5WE 400 37IUHP5WED 400A/600V 37IUHP5WEF 150 37IUHP5WEP<br />

150 4 50–200 B 36JUHP5WE 400 37JUHP5WED 400A/600V 37JUHP5WEF 250 37JUHP5WEP<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-41


Reduced Voltage Heavy Duty Starters<br />

Revised on 08/31/18<br />

2 Step Part Winding with Solid State Overload, Class 36 & 37 Selection<br />

Ordering Information<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page page 17-150.<br />

Wiring Diagrams see page 17-162.<br />

Replacement Parts see page 17-120.<br />

Coil and Control Voltage<br />

The coil voltage will always match the<br />

motor voltage. As standard, a CPT is<br />

supplied and 120V control voltage is<br />

utilized. To change to 120V voltage (CPT<br />

not supplied), change the 9th character<br />

to “F”. To change to 24VAC voltage<br />

(CPT not supplied), change the 9th<br />

character to “J”.<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

NEMA 12, NEMA 3/3R<br />

Motor<br />

Voltage<br />

200<br />

230<br />

460<br />

575<br />

Max<br />

Hp<br />

Overload Relay<br />

NEMA<br />

Size Amp<br />

(1/2 Size) Range<br />

Frame<br />

Size<br />

Non-Combination<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Combination Non-Fusible<br />

Disconnect<br />

Disc.<br />

Amp Catalog List<br />

Rating Number Price $<br />

Call Combination Fusible Disconnect<br />

Call<br />

Fuse Clip<br />

Amp/Volt Catalog List<br />

Rating Number Price $<br />

Combination Circit Breaker<br />

Circuit<br />

Breaker Catalog List<br />

Amps Number Price $<br />

7½ 0 5.5–22 A1 36CUDP6ND 60 37CUDP6NDD 60A/250V 37CUDP6NDF 30 37CUDP6NDP<br />

10 1 5.5–22 A1 36DUDP6ND 60 37DUDP6NDD 60A/250V 37DUDP6NDF 50 37DUDP6NDP<br />

15 (1¾) 10–40 A1 36EUEP6ND 100 37EUEP6NDD 100A/250V 37EUEP6NDF 100 37EUEP6NDP<br />

20 2 13–52 B 36FUFP6ND 100 37FUFP6NDD 100A/250V 37FUFP6NDF 100 37FUFP6NDP<br />

30 (2½) 25–100 B 36GUGP6ND 200 37GUGP6NDD 200A/250V 37GUGP6NDF 125 37GUGP6NDP<br />

40 3 25–100 B 36HUGP6ND 200 37HUGP6NDD 200A/250V 37HUGP6NDF 150 37HUGP6NDP<br />

50 (3½) 50–200 B 36IUHP6ND 200 37IUHP6NDD 200A/250V 37IUHP6NDF 250 37IUHP6NDP<br />

75 4 50–200 B 36JUHP6ND 400 37JUHP6NDD 400A/250V 37JUHP6NDF 400 37JUHP6NDP<br />

100 5 55–250 — — — — — — 600 37LPSP6NDP<br />

150 5 55–250 — 36LPUP6ND 600 37LPUP6NDD 600A/250V 37LPUP6NDF 600 37LPUP6NDP<br />

7½ 0 5.5–22 A1 36CUDP2NG 60 37CUDP2NGD 60A/250V 37CUDP2NGF 30 37CUDP2NGP<br />

10 1 5.5–22 A1 36DUDP2NG 60 37DUDP2NGD 60A/250V 37DUDP2NGF 50 37DUDP2NGP<br />

20 (1½) 10–40 A1 36EUEP2NG 100 37EUEP2NGD 100A/250V 37EUEP2NGF 100 37EUEP2NGP<br />

25 2 13–52 B 36FUFP2NG 100 37FUFP2NGD 100A/250V 37FUFP2NGF 100 37FUFP2NGP<br />

30 (2½) 25–100 B 36GUGP2NG 200 37GUGP2NGD 200A/250V 37GUGP2NGF 100 37GUGP2NGP<br />

50 3 25–100 B 36HUGP2NG 200 37HUGP2NGD 200A/250V 37HUGP2NGF 150 37HUGP2NGP<br />

60 (3½) 50–200 B 36IUHP2NG 200 37IUHP2NGD 200A/250V 37IUHP2NGF 250 37IUHP2NGP<br />

75 4 50–200 B 36JUHP2NG 400 37JUHP2NGD 400A/250V 37JUHP2NGF 250 37JUHP2NGP<br />

125 5 55–250 — — — — — — 400 37LPSP2NGP<br />

150 5 55–250 — 36LPUP2NG 600 37LPUP2NGD 600A/250V 37LPUP2NGF 600 37LPUP2NGP<br />

300 6 160–630 — 36MPXP2NG 1200 37MPXP2NGD 1200A/250V 37MPXP2NGF 1200 37MPXP2NGP<br />

10 0 5.5–22 A1 36CUDP4NH 30 37CUDP4NHD 30A/600V 37CUDP4NHF 30 37CUDP4NHP<br />

15 1 5.5–22 A1 36DUDP4NH 60 37DUDP4NHD 60A/600V 37DUDP4NHF 30 37DUDP4NHP<br />

30 (1¾) 10–40 A1 36EUEP4NH 60 37EUEP4NHD 60A/600V 37EUEP4NHF 50 37EUEP4NHP<br />

40 2 13–52 B 36FUFP4NH 100 37FUFP4NHD 100A/600V 37FUFP4NHF 100 37FUFP4NHP<br />

60 (2½) 25–100 B 36GUGP4NH 200 37GUGP4NHD 200A/600V 37GUGP4NHF 100 37GUGP4NHP<br />

75 3 25–100 B 36HUGP4NH 200 37HUGP4NHD 200A/600V 37HUGP4NHF 125 37HUGP4NHP<br />

100 (3½) 50–200 B 36IUHP4NH 200 37IUHP4NHD 200A/600V 37IUHP4NHF 150 37IUHP4NHP<br />

150 4 50–200 B 36JUHP4NH 400 37JUHP4NHD 400A/600V 37JUHP4NHF 250 37JUHP4NHP<br />

250 5 55–250 — — — — — — 400 37LPSP4NHP<br />

350 5 55–250 — 36LPUP4NH 600 37LPUP4NHD 600A/600V 37LPUP4NHF 600 37LPUP4NHP<br />

600 6 160–630 — 36MPXP4NH 1200 37MPXP4NHD 1200A/600V 37MPXP4NHF 1200 37MPXP4NHP<br />

10 0 5.5–22 A1 36CUDP5NE 30 37CUDP5NED 30A/600V 37CUDP5NEF 30 37CUDP5NEP<br />

15 1 5.5–22 A1 36DUDP5NE 60 37DUDP5NED 60A/600V 37DUDP5NEF 30 37DUDP5NEP<br />

30 (1¾) 10–40 A1 36EUEP5NE 60 37EUEP5NED 60A/600V 37EUEP5NEF 50 37EUEP5NEP<br />

40 2 13–52 B 36FUFP5NE 60 37FUFP5NED 60A/600V 37FUFP5NEF 50 37FUFP5NEP<br />

60 (2½) 25–100 B 36GUGP5NE 100 37GUGP5NED 100A/600V 37GUGP5NEF 100 37GUGP5NEP<br />

75 3 25–100 B 36HUGP5NE 200 37HUGP5NED 200A/600V 37HUGP5NEF 125 37HUGP5NEP<br />

100 (3½) 50–200 B 36IUHP5NE 400 37IUHP5NED 400A/600V 37IUHP5NEF 150 37IUHP5NEP<br />

150 4 50–200 B 36JUHP5NE 400 37JUHP5NED 400A/600V 37JUHP5NEF 250 37JUHP5NEP<br />

250 5 55–250 — — — — 400A/600V 37LPSP5NEF — —<br />

350 5 55–250 — 36LPUP5NE 600 37LPUP5NED 600A/600V 37LPUP5NEF 400 37LPUP5NEP<br />

600 6 160–630 — 36MPXP5NE 1200 37MPXP5NED 1200A/600V 37MPXP5NEF 1200 37MPXP5NEP<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

17-42<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Reduced Voltage Heavy Duty Starters<br />

Wye Delta, Open Transition with Solid State Overload, Class 36 & 37<br />

Ordering Information<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-150.<br />

Wiring Diagrams see page 17-164 .<br />

Replacement Parts see page 17-120.<br />

Revised on 03/31/20<br />

Coil and Control Voltage<br />

Selection<br />

The coil voltage will always match the<br />

motor voltage. As standard, a CPT is<br />

supplied and 120V control voltage is<br />

utilized. To change to 120V voltage (CPT<br />

not supplied), change the 9th character<br />

to “F”. To change to 24VAC voltage<br />

(CPT not supplied), change the 9th<br />

character to “J”.<br />

NEMA 1 General Purpose Enclosures<br />

Motor<br />

Voltage<br />

200<br />

230<br />

460<br />

575<br />

Max<br />

Hp<br />

NEMA<br />

Size<br />

(1/2 Size)<br />

Overload Relay<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

Non-Combination<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Combination Non-Fusible<br />

Disconnect Combination Fusible Disconnect Combination Circit Breaker<br />

Disc.<br />

Fuse Clip<br />

Circuit<br />

Amp Catalog List Amp/Volt Catalog List Breaker Catalog List<br />

Rating Number Price $ Rating Number Price $ Amps Number Price $<br />

10 1 10–40 A1 36DUE06BD 60 37DUE06BDD 60A/250V 37DUE06BDF 50 37DUE06BDP<br />

15 (1¾) 10–40 A1 36EUE06BD 100 37EUE06BDD 100A/250V 37EUE06BDF 100 37EUE06BDP<br />

20 2 13–52 B 36FUF06BD 100 37FUF06BDD 100A/250V 37FUF06BDF 100 37FUF06BDP<br />

30 (2½) 25–100 B 36GUG06BD 200 37GUG06BDD 200A/250V 37GUG06BDF 125 37GUG06BDP<br />

40 3 25–100 B 36HUG06BD 200 37HUG06BDD 200A/250V 37HUG06BDF 150 37HUG06BDP<br />

50 (3½) 50–200 B 36IUH06BD 200 37IUH06BDD 200A/250V 37IUH06BDF 250 37IUH06BDP<br />

60 4 50–200 B 36JUH06BD 400 37JUH06BDD 400A/250V 37JUH06BDF 250 37JUH06BDP<br />

75 5 55–250 — 36LPS06BD 400 37LPS06BDD 400A/250V 37LPS06BDF 400 37LPS06BDP<br />

150 5 55–250 — 36LPU06BD 600 37LPU06BDD 600A/250V 37LPU06BDF 600 37LPU06BDP<br />

300 6 160–630 — 36MPX06BD 1200 37MPX06BDD 1200A/250V 37MPX06BDF 1200 37MPX06BDP<br />

10 1 10–40 A1 36DUE02BG 60 37DUE02BGD 60A/250V 37DUE02BGF 50 37DUE02BGP<br />

15 (1¾) 10–40 A1 36EUE02BG 60 37EUE02BGD 60A/250V 37EUE02BGF 50 37EUE02BGP<br />

25 2 13–52 B 36FUF02BG 100 37FUF02BGD 100A/250V 37FUF02BGF 100 37FUF02BGP<br />

30 (2½) 25–100 B 36GUG02BG 200 37GUG02BGD 200A/250V 37GUG02BGF 100 37GUG02BGP<br />

50 3 25–100 B 36HUG02BG 200 37HUG02BGD 200A/250V 37HUG02BGF 150 37HUG02BGP<br />

60 (3½) 50–200 B 36IUH02BG 200 37IUH02BGD 200A/250V 37IUH02BGF 250 37IUH02BGP<br />

75 4 50–200 B 36JUH02BG 400 37JUH02BGD 400A/250V 37JUH02BGF 250 37JUH02BGP<br />

100 5 55–250 — 36LPS02BG 400 37LPS02BGD 400A/250V 37LPS02BGF 400 37LPS02BGP<br />

150 5 55–250 — 36LPU02BG 600 37LPU02BGD 600A/250V 37LPU02BGF 600 37LPU02BGP<br />

350 6 160–630 — 36MPX02BG 1200 37MPX02BGD 1200A/250V 37MPX02BGF 1200 37MPX02BGP<br />

15 1 5.5-22 A1 36DUD04BH 30 37DUD04BHD 30A/600V 37DUD04BHF 30 37DUD04BHP<br />

30 (1¾) 10–40 A1 36EUE04BH 60 37EUE04BHD 60A/600V 37EUE04BHF 50 37EUE04BHP<br />

40 2 13–52 B 36FUF04BH 100 37FUF04BHD 100A/600V 37FUF04BHF 100 37FUF04BHP<br />

60 (2½) 25–100 B 36GUG04BH 200 37GUG04BHD 200A/600V 37GUG04BHF 100 37GUG04BHP<br />

75 3 25–100 B 36HUG04BH 200 37HUG04BHD 200A/600V 37HUG04BHF 125 37HUG04BHP<br />

100 (3½) 50–200 B 36IUH04BH 200 37IUH04BHD 200A/600V 37IUH04BHF 150 37IUH04BHP<br />

150 4 50–200 B 36JUH04BH 400 37JUH04BHD 400A/600V 37JUH04BHF 250 37JUH04BHP<br />

200 5 55–250 — 36LPS04BH 400 37LPS04BHD 400A/600V 37LPS04BHF 400 37LPS04BHP<br />

300 5 55–250 — 36LPU04BH 600 37LPU04BHD 600A/600V 37LPU04BHF 600 37LPU04BHP<br />

700 6 160–630 — 36MPX04BH 1600 37MPX04BHD 1600A/600V 37MPX04BHF 1200 37MPX04BHP<br />

15 1 5.5-22 A1 36DUD05BE 30 37DUD05BED 30A/600V 37DUD05BEF 30 37DUD05BEP<br />

30 (1¾) 10–40 A1 36EUE05BE 60 37EUE05BED 60A/600V 37EUE05BEF 50 37EUE05BEP<br />

40 2 13–52 B 36FUF05BE 100 37FUF05BED 100A/600V 37FUF05BEF 50 37FUF05BEP<br />

60 (2½) 25–100 B 36GUG05BE 100 37GUG05BED 100A/600V 37GUG05BEF 100 37GUG05BEP<br />

75 3 25–100 B 36HUG05BE 200 37HUG05BED 200A/600V 37HUG05BEF 125 37HUG05BEP<br />

100 (3½) 50–200 B 36IUH05BE 200 37IUH05BED 200A/600V 37IUH05BEF 150 37IUH05BEP<br />

150 4 50–200 B 36JUH05BE 400 37JUH05BED 400A/600V 37JUH05BEF 250 37JUH05BEP<br />

200 5 55–250 — 36LPS05BE 400 37LPS05BED 400A/600V 37LPS05BEF 250 37LPS05BEP<br />

300 5 55–250 — 36LPU05BE 600 37LPU05BED 600A/600V 37LPU05BEF 400 37LPU05BEP<br />

700 6 160–630 — 36MPX05BE 1600 37MPX05BED 1600A/600V 37MPX05BEF 1600 37MPX05BEP<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-43


Reduced Voltage Heavy Duty Starters<br />

Wye Delta, Open Transition with Solid State Overload, Class 36 & 37<br />

Ordering Information<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-150.<br />

Wiring Diagrams see page 17-164 .<br />

Replacement Parts see page 17-120.<br />

Coil and Control Voltage<br />

Selection<br />

The coil voltage will always match the<br />

motor voltage. As standard, a CPT is<br />

supplied and 120V control voltage is<br />

utilized. To change to 120V voltage (CPT<br />

not supplied), change the 9th character<br />

to “F”. To change to 24VAC voltage<br />

(CPT not supplied), change the 9th<br />

character to “J”.<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

NEMA 4 Painted Enclosures<br />

Motor<br />

Voltage<br />

200<br />

230<br />

460<br />

575<br />

Max<br />

Hp<br />

NEMA<br />

Size<br />

(1/2 Size)<br />

Overload Relay<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

Non-Combination<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Combination Non-Fusible<br />

Disconnect Combination Fusible Disconnect Combination Circit Breaker<br />

Disc.<br />

Fuse Clip<br />

Circuit<br />

Amp Catalog List Amp/Volt Catalog List Breaker Catalog List<br />

Rating Number Price $ Rating Number Price $ Amps Number Price $<br />

10 1 10–40 A1 36DUE06ED 60 37DUE06EDD 60A/250V 37DUE06EDF 50 37DUE06EDP<br />

15 (1¾) 10–40 A1 36EUE06ED 100 37EUE06EDD 100A/250V 37EUE06EDF 100 37EUE06EDP<br />

20 2 13–52 B 36FUF06ED 100 37FUF06EDD 100A/250V 37FUF06EDF 100 37FUF06EDP<br />

30 (2½) 25–100 B 36GUG06ED 200 37GUG06EDD 200A/250V 37GUG06EDF 125 37GUG06EDP<br />

40 3 25–100 B 36HUG06ED 200 37HUG06EDD 200A/250V 37HUG06EDF 150 37HUG06EDP<br />

50 (3½) 50–200 B 36IUH06ED 200 37IUH06EDD 200A/250V 37IUH06EDF 250 37IUH06EDP<br />

60 4 50–200 B 36JUH06ED 400 37JUH06EDD 400A/250V 37JUH06EDF 250 37JUH06EDP<br />

75 5 55–250 — 36LPS06ED 400 37LPS06EDD 400A/250V 37LPS06EDF 400 37LPS06EDP<br />

150 5 55–250 — 36LPU06ED 600 37LPU06EDD 600A/250V 37LPU06EDF 600 37LPU06EDP<br />

300 6 160–630 — 36MPX06ED 1200 37MPX06EDD 1200A/250V 37MPX06EDF 1200 37MPX06EDP<br />

10 1 10–40 A1 36DUE02EG 60 37DUE02EGD 60A/250V 37DUE02EGF 50 37DUE02EGP<br />

15 (1¾) 10–40 A1 36EUE02EG 60 37EUE02EGD 60A/250V 37EUE02EGF 50 37EUE02EGP<br />

25 2 13–52 B 36FUF02EG 100 37FUF02EGD 100A/250V 37FUF02EGF 100 37FUF02EGP<br />

30 (2½) 25–100 B 36GUG02EG 200 37GUG02EGD 200A/250V 37GUG02EGF 100 37GUG02EGP<br />

50 3 25–100 B 36HUG02EG 200 37HUG02EGD 200A/250V 37HUG02EGF 150 37HUG02EGP<br />

60 (3½) 50–200 B 36IUH02EG 200 37IUH02EGD 200A/250V 37IUH02EGF 250 37IUH02EGP<br />

75 4 50–200 B 36JUH02EG 400 37JUH02EGD 400A/250V 37JUH02EGF 250 37JUH02EGP<br />

100 5 55–250 — 36LPS02EG 400 37LPS02EGD 400A/250V 37LPS02EGF 400 37LPS02EGP<br />

150 5 55–250 — 36LPU02EG 600 37LPU02EGD 600A/250V 37LPU02EGF 600 37LPU02EGP<br />

350 6 160–630 — 36MPX02EG 1200 37MPX02EGD 1200A/250V 37MPX02EGF 1200 37MPX02EGP<br />

15 1 5.5-22 A1 36DUD04EH 30 37DUD04EHD 30A/600V 37DUD04EHF 30 37DUD04EHP<br />

30 (1¾) 10–40 A1 36EUE04EH 60 37EUE04EHD 60A/600V 37EUE04EHF 50 37EUE04EHP<br />

40 2 13–52 B 36FUF04EH 100 37FUF04EHD 100A/600V 37FUF04EHF 100 37FUF04EHP<br />

60 (2½) 25–100 B 36GUG04EH 200 37GUG04EHD 200A/600V 37GUG04EHF 100 37GUG04EHP<br />

75 3 25–100 B 36HUG04EH 200 37HUG04EHD 200A/600V 37HUG04EHF 125 37HUG04EHP<br />

100 (3½) 50–200 B 36IUH04EH 200 37IUH04EHD 200A/600V 37IUH04EHF 150 37IUH04EHP<br />

150 4 50–200 B 36JUH04EH 400 37JUH04EHD 400A/600V 37JUH04EHF 250 37JUH04EHP<br />

200 5 55–250 — 36LPS04EH 400 37LPS04EHD 400A/600V 37LPS04EHF 400 37LPS04EHP<br />

300 5 55–250 — 36LPU04EH 600 37LPU04EHD 600A/600V 37LPU04EHF 600 37LPU04EHP<br />

700 6 160–630 — 36MPX04EH 1600 37MPX04EHD 1600A/600V 37MPX04EHF 1200 37MPX04EHP<br />

15 1 5.5-22 A1 36DUD05EE 30 37DUD05EED 30A/600V 37DUD05EEF 30 37DUD05EEP<br />

30 (1¾) 10–40 A1 36EUE05EE 60 37EUE05EED 60A/600V 37EUE05EEF 50 37EUE05EEP<br />

40 2 13–52 B 36FUF05EE 100 37FUF05EED 100A/600V 37FUF05EEF 50 37FUF05EEP<br />

60 (2½) 25–100 B 36GUG05EE 100 37GUG05EED 100A/600V 37GUG05EEF 100 37GUG05EEP<br />

75 3 25–100 B 36HUG05EE 200 37HUG05EED 200A/600V 37HUG05EEF 125 37HUG05EEP<br />

100 (3½) 50–200 B 36IUH05EE 200 37IUH05EED 200A/600V 37IUH05EEF 150 37IUH05EEP<br />

150 4 50–200 B 36JUH05EE 400 37JUH05EED 400A/600V 37JUH05EEF 250 37JUH05EEP<br />

200 5 55–250 — 36LPS05EE 400 37LPS05EED 400A/600V 37LPS05EEF 250 37LPS05EEP<br />

300 5 55–250 — 36LPU05EE 600 37LPU05EED 600A/600V 37LPU05EEF 400 37LPU05EEP<br />

700 6 160–630 — 37MPX05EF 1600 37MPX05EED 1600A/600V 37MPX05EEF 1600 37MPX05EEP<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

17-44<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Reduced Voltage Heavy Duty Starters<br />

Wye Delta, Open Transition with Solid State Overload, Class 36 & 37<br />

Ordering Information<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-150.<br />

Wiring Diagrams see page 17-164 .<br />

Replacement Parts see page 17-120.<br />

Coil and Control Voltage<br />

Selection<br />

The coil voltage will always match the<br />

motor voltage. As standard, a CPT is<br />

supplied and 120V control voltage is<br />

utilized. To change to 120V voltage (CPT<br />

not supplied), change the 9th character<br />

to “F”. To change to 24VAC voltage<br />

(CPT not supplied), change the 9th<br />

character to “J”.<br />

NEMA 4/4X Stainless Steel Enclosures<br />

Motor<br />

Voltage<br />

200<br />

230<br />

460<br />

575<br />

Max<br />

Hp<br />

NEMA<br />

Size<br />

(1/2 Size)<br />

Overload Relay<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

Non-Combination<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Combination Non-Fusible<br />

Disconnect Combination Fusible Disconnect Combination Circit Breaker<br />

Disc.<br />

Fuse Clip<br />

Circuit<br />

Amp Catalog List Amp/Volt Catalog List Breaker Catalog List<br />

Rating Number Price $ Rating Number Price $ Amps Number Price $<br />

10 1 10–40 A1 36DUE06WD 60 37DUE06WDD 60A/250V 37DUE06WDF 50 37DUE06WDP<br />

15 (1¾) 10–40 A1 36EUE06WD 100 37EUE06WDD 100A/250V 37EUE06WDF 100 37EUE06WDP<br />

20 2 13–52 B 36FUF06WD 100 37FUF06WDD 100A/250V 37FUF06WDF 100 37FUF06WDP<br />

30 (2½) 25–100 B 36GUG06WD 200 37GUG06WDD 200A/250V 37GUG06WDF 125 37GUG06WDP<br />

40 3 25–100 B 36HUG06WD 200 37HUG06WDD 200A/250V 37HUG06WDF 150 37HUG06WDP<br />

50 (3½) 50–200 B 36IUH06WD 200 37IUH06WDD 200A/250V 37IUH06WDF 250 37IUH06WDP<br />

60 4 50–200 B 36JUH06WD 400 37JUH06WDD 400A/250V 37JUH06WDF 250 37JUH06WDP<br />

10 1 10–40 A1 36DUE02WG 60 37DUE02WGD 60A/250V 37DUE02WGF 50 37DUE02WGP<br />

15 (1¾) 10–40 A1 36EUE02WG 60 37EUE02WGD 60A/250V 37EUE02WGF 50 37EUE02WGP<br />

25 2 13–52 B 36FUF02WG 100 37FUF02WGD 100A/250V 37FUF02WGF 100 37FUF02WGP<br />

30 (2½) 25–100 B 36GUG02WG 200 37GUG02WGD 200A/250V 37GUG02WGF 100 37GUG02WGP<br />

50 3 25–100 B 36HUG02WG 200 37HUG02WGD 200A/250V 37HUG02WGF 150 37HUG02WGP<br />

60 (3½) 50–200 B 36IUH02WG 200 37IUH02WGD 200A/250V 37IUH02WGF 250 37IUH02WGP<br />

75 4 50–200 B 36JUH02WG 400 37JUH02WGD 400A/250V 37JUH02WGF 250 37JUH02WGP<br />

15 1 5.5-22 A1 36DUD04WH 30 37DUD04WHD 30A/600V 37DUD04WHF 30 37DUD04WHP<br />

30 (1¾) 10–40 A1 36EUE04WH 60 37EUE04WHD 60A/600V 37EUE04WHF 50 37EUE04WHP<br />

40 2 13–52 B 36FUF04WH 100 37FUF04WHD 100A/600V 37FUF04WHF 100 37FUF04WHP<br />

60 (2½) 25–100 B 36GUG04WH 200 37GUG04WHD 200A/600V 37GUG04WHF 100 37GUG04WHP<br />

75 3 25–100 B 36HUG04WH 200 37HUG04WHD 200A/600V 37HUG04WHF 125 37HUG04WHP<br />

100 (3½) 50–200 B 36IUH04WH 200 37IUH04WHD 200A/600V 37IUH04WHF 150 37IUH04WHP<br />

150 4 50–200 B 36JUH04WH 400 37JUH04WHD 400A/600V 37JUH04WHF 250 37JUH04WHP<br />

15 1 5.5-22 A1 36DUD05WE 30 37DUD05WED 30A/600V 37DUD05WEF 30 37DUD05WEP<br />

30 (1¾) 10–40 A1 36EUE05WE 60 37EUE05WED 60A/600V 37EUE05WEF 50 37EUE05WEP<br />

40 2 13–52 B 36FUF05WE 100 37FUF05WED 100A/600V 37FUF05WEF 50 37FUF05WEP<br />

60 (2½) 25–100 B 36GUG05WE 100 37GUG05WED 100A/600V 37GUG05WEF 100 37GUG05WEP<br />

75 3 25–100 B 36HUG05WE 200 37HUG05WED 200A/600V 37HUG05WEF 125 37HUG05WEP<br />

100 (3½) 50–200 B 36IUH05WE 200 37IUH05WED 200A/600V 37IUH05WEF 150 37IUH05WEP<br />

150 4 50–200 B 36JUH05WE 400 37JUH05WED 400A/600V 37JUH05WEF 250 37JUH05WEP<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-45


Reduced Voltage Heavy Duty Starters<br />

Wye Delta, Open Transition with Solid State Overload, Class 36 & 37<br />

Ordering Information<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-150.<br />

Wiring Diagrams see page 17-164 .<br />

Replacement Parts see page 17-120.<br />

Revised on 08/31/18<br />

Coil and Control Voltage<br />

Selection<br />

The coil voltage will always match the<br />

motor voltage. As standard, a CPT is<br />

supplied and 120V control voltage is<br />

utilized. To change to 120V voltage (CPT<br />

not supplied), change the 9th character<br />

to “F”. To change to 24VAC voltage<br />

(CPT not supplied), change the 9th<br />

character to “J”.<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

NEMA 12, NEMA 3/3R<br />

Motor<br />

Voltage<br />

200<br />

230<br />

460<br />

575<br />

Max<br />

Hp<br />

NEMA<br />

Size<br />

(1/2 Size)<br />

Overload Relay<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

Non-Combination<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Combination Non-Fusible<br />

Disconnect Combination Fusible Disconnect Combination Circit Breaker<br />

Disc.<br />

Fuse Clip<br />

Circuit<br />

Amp Catalog List Amp/Volt Catalog List Breaker Catalog List<br />

Rating Number Price $ Rating Number Price $ Amps Number Price $<br />

10 1 10–40 A1 36DUE06ND 60 37DUE06NDD 60A/250V 37DUE06NDF 50 37DUE06NDP<br />

15 (1¾) 10–40 A1 36EUE06ND 100 37EUE06NDD 100A/250V 37EUE06NDF 100 37EUE06NDP<br />

20 2 13–52 B 36FUF06ND 100 37FUF06NDD 100A/250V 37FUF06NDF 100 37FUF06NDP<br />

30 (2½) 25–100 B 36GUG06ND 200 37GUG06NDD 200A/250V 37GUG06NDF 125 37GUG06NDP<br />

40 3 25–100 B 36HUG06ND 200 37HUG06NDD 200A/250V 37HUG06NDF 150 37HUG06NDP<br />

50 (3½) 50–200 B 36IUH06ND 200 37IUH06NDD 200A/250V 37IUH06NDF 250 37IUH06NDP<br />

60 4 50–200 B 36JUH06ND 400 37JUH06NDD 400A/250V 37JUH06NDF 250 37JUH06NDP<br />

75 5 55–250 — 36LPS06ND 400 37LPS06NDD 400A/250V 37LPS06NDF 400 37LPS06NDP<br />

150 5 55–250 — 36LPU06ND 600 37LPU06NDD 600A/250V 37LPU06NDF 600 37LPU06NDP<br />

300 6 160–630 — 36MPX06ND 1200 37MPX06NDD 1200A/250V 37MPX06NDF 1200 37MPX06NDP<br />

10 1 10–40 A1 36DUE02NG 60 37DUE02NGD 60A/250V 37DUE02NGF 50 37DUE02NGP<br />

15 (1¾) 10–40 A1 36EUE02NG 60 37EUE02NGD 60A/250V 37EUE02NGF 50 37EUE02NGP<br />

25 2 13–52 B 36FUF02NG 100 37FUF02NGD 100A/250V 37FUF02NGF 100 37FUF02NGP<br />

30 (2½) 25–100 B 36GUG02NG 200 37GUG02NGD 200A/250V 37GUG02NGF 100 37GUG02NGP<br />

50 3 25–100 B 36HUG02NG 200 37HUG02NGD 200A/250V 37HUG02NGF 150 37HUG02NGP<br />

60 (3½) 50–200 B 36IUH02NG 200 37IUH02NGD 200A/250V 37IUH02NGF 250 37IUH02NGP<br />

75 4 50–200 B 36JUH02NG 400 37JUH02NGD 400A/250V 37JUH02NGF 250 37JUH02NGP<br />

100 5 55–250 — 36LPS02NG 400 37LPS02NGD 400A/250V 37LPS02NGF 400 37LPS02NGP<br />

150 5 55–250 — 36LPU02NG 600 37LPU02NGD 600A/250V 37LPU02NGF 600 37LPU02NGP<br />

350 6 160–630 — 36MPX02NG 1200 37MPX02NGD 1200A/250V 37MPX02NGF 1200 37MPX02NGP<br />

15 1 5.5-22 A1 36DUD04NH 30 37DUD04NHD 30A/600V 37DUD04NHF 30 37DUD04NHP<br />

30 (1¾) 10–40 A1 36EUE04NH 60 37EUE04NHD 60A/600V 37EUE04NHF 50 37EUE04NHP<br />

40 2 13–52 B 36FUF04NH 100 37FUF04NHD 100A/600V 37FUF04NHF 100 37FUF04NHP<br />

60 (2½) 25–100 B 36GUG04NH 200 37GUG04NHD 200A/600V 37GUG04NHF 100 37GUG04NHP<br />

75 3 25–100 B 36HUG04NH 200 37HUG04NHD 200A/600V 37HUG04NHF 125 37HUG04NHP<br />

100 (3½) 50–200 B 36IUH04NH 200 37IUH04NHD 200A/600V 37IUH04NHF 150 37IUH04NHP<br />

150 4 50–200 B 36JUH04NH 400 37JUH04NHD 400A/600V 37JUH04NHF 250 37JUH04NHP<br />

200 5 55–250 — 36LPS04NH 400 37LPS04NHD 400A/600V 37LPS04NHF 400 37LPS04NHP<br />

300 5 55–250 — 36LPU04NH 600 37LPU04NHD 600A/600V 37LPU04NHF 600 37LPU04NHP<br />

700 6 160–630 — 36MPX04NH 1600 37MPX04NHD 1600A/600V 37MPX04NHF 1200 37MPX04NHP<br />

15 1 5.5-22 A1 36DUD05NE 30 37DUD05NED 30A/600V 37DUD05NEF 30 37DUD05NEP<br />

30 (1¾) 10–40 A1 36EUE05NE 60 37EUE05NED 60A/600V 37EUE05NEF 50 37EUE05NEP<br />

40 2 13–52 B 36FUF05NE 100 37FUF05NED 100A/600V 37FUF05NEF 50 37FUF05NEP<br />

60 (2½) 25–100 B 36GUG05NE 100 37GUG05NED 100A/600V 37GUG05NEF 100 37GUG05NEP<br />

75 3 25–100 B 36HUG05NE 200 37HUG05NED 200A/600V 37HUG05NEF 125 37HUG05NEP<br />

100 (3½) 50–200 B 36IUH05NE 200 37IUH05NED 200A/600V 37IUH05NEF 150 37IUH05NEP<br />

150 4 50–200 B 36JUH05NE 400 37JUH05NED 400A/600V 37JUH05NEF 250 37JUH05NEP<br />

200 5 55–250 — 36LPS05NE 400 37LPS05NED 400A/600V 37LPS05NEF 250 37LPS05NEP<br />

300 5 55–250 — 36LPU05NE 600 37LPU05NED 600A/600V 37LPU05NEF 400 37LPU05NEP<br />

700 6 160–630 — 37MPX05NF 1600 37MPX05NED 1600A/600V 37MPX05NEF 1600 37MPX05NEP<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

17-46<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Reduced Voltage Heavy Duty Starters<br />

Wye Delta, Closed Transition with Solid State Overload, Class 36 & 37<br />

Ordering Information<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-150.<br />

Wiring Diagrams see page 17-165.<br />

Replacement Parts see page 17-120.<br />

Coil and Control Voltage<br />

Selection<br />

The coil voltage will always match the<br />

motor voltage. As standard, a CPT is<br />

supplied and 120V control voltage is<br />

utilized. To change to 120V voltage (CPT<br />

not supplied), change the 9th character<br />

to “F”. To change to 24VAC voltage<br />

(CPT not supplied), change the 9th<br />

character to “J”.<br />

NEMA 1 General Purpose Enclosures<br />

Motor<br />

Voltage<br />

200<br />

230<br />

460<br />

575<br />

Max<br />

Hp<br />

Overload Relay<br />

NEMA<br />

Size Amp<br />

(1/2 Size) Range<br />

Frame<br />

Size<br />

Non-Combination<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Combination Non-Fusible<br />

Disconnect Combination Fusible Disconnect Combination Circit Breaker<br />

Disc.<br />

Fuse Clip<br />

Circuit<br />

Amp Catalog List Amp/Volt Catalog List Breaker Catalog List<br />

Rating Number Price $ Rating Number Price $ Amps Number Price $<br />

10 1 10–40 A1 36DUEC6BD 60 37DUEC6BDD 60A/250V 37DUEC6BDF 50 37DUEC6BDP<br />

15 (1¾) 10–40 A1 36EUEC6BD 100 37EUEC6BDD 100A/250V 37EUEC6BDF 100 37EUEC6BDP<br />

20 2 13–52 B 36FUFC6BD 100 37FUFC6BDD 100A/250V 37FUFC6BDF 100 37FUFC6BDP<br />

30 (2½) 25–100 B 36GUGC6BD 200 37GUGC6BDD 200A/250V 37GUGC6BDF 125 37GUGC6BDP<br />

40 3 25–100 B 36HUGC6BD 200 37HUGC6BDD 200A/250V 37HUGC6BDF 150 37HUGC6BDP<br />

50 (3½) 50–200 B 36IUHC6BD 200 37IUHC6BDD 200A/250V 37IUHC6BDF 250 37IUHC6BDP<br />

60 4 50–200 B 36JUHC6BD 400 37JUHC6BDD 400A/250V 37JUHC6BDF 250 37JUHC6BDP<br />

75 5 55–250 — 36LPSC6BD 400 37LPSC6BDD 400A/250V 37LPSC6BDF 400 37LPSC6BDP<br />

150 5 55–250 — 36LPUC6BD 600 37LPUC6BDD 600A/250V 37LPUC6BDF 600 37LPUC6BDP<br />

300 6 160–630 — 36MPXC6BD 1200 37MPXC6BDD 1200A/250V 37MPXC6BDF 1200 37MPXC6BDP<br />

10 1 10–40 A1 36DUEC2BG 60 37DUEC2BGD 60A/250V 37DUEC2BGF 50 37DUEC2BGP<br />

15 (1¾) 10–40 A1 36EUEC2BG 60 37EUEC2BGD 60A/250V 37EUEC2BGF 50 37EUEC2BGP<br />

25 2 13–52 B 36FUFC2BG 100 37FUFC2BGD 100A/250V 37FUFC2BGF 100 37FUFC2BGP<br />

30 (2½) 25–100 B 36GUGC2BG 200 37GUGC2BGD 200A/250V 37GUGC2BGF 100 37GUGC2BGP<br />

50 3 25–100 B 36HUGC2BG 200 37HUGC2BGD 200A/250V 37HUGC2BGF 150 37HUGC2BGP<br />

60 (3½) 50–200 B 36IUHC2BG 200 37IUHC2BGD 200A/250V 37IUHC2BGF 250 37IUHC2BGP<br />

75 4 50–200 B 36JUHC2BG 400 37JUHC2BGD 400A/250V 37JUHC2BGF 250 37JUHC2BGP<br />

100 5 55–250 — 36LPSC2BG 400 37LPSC2BGD 400A/250V 37LPSC2BGF 400 37LPSC2BGP<br />

150 5 55–250 — 36LPUC2BG 600 37LPUC2BGD 600A/250V 37LPUC2BGF 600 37LPUC2BGP<br />

350 6 160–630 — 36MPXC2BG 1200 37MPXC2BGD 1200A/250V 37MPXC2BGF 1200 37MPXC2BGP<br />

15 1 5.5-22 A1 36DUDC4BH 30 37DUDC4BHD 30A/600V 37DUDC4BHF 30 37DUDC4BHP<br />

30 (1¾) 10–40 A1 36EUEC4BH 60 37EUEC4BHD 60A/600V 37EUEC4BHF 50 37EUEC4BHP<br />

40 2 13–52 B 36FUFC4BH 100 37FUFC4BHD 100A/600V 37FUFC4BHF 100 37FUFC4BHP<br />

60 (2½) 25–100 B 36GUGC4BH 200 37GUGC4BHD 200A/600V 37GUGC4BHF 100 37GUGC4BHP<br />

75 3 25–100 B 36HUGC4BH 200 37HUGC4BHD 200A/600V 37HUGC4BHF 125 37HUGC4BHP<br />

100 (3½) 50–200 B 36IUHC4BH 200 37IUHC4BHD 200A/600V 37IUHC4BHF 150 37IUHC4BHP<br />

150 4 50–200 B 36JUHC4BH 400 37JUHC4BHD 400A/600V 37JUHC4BHF 250 37JUHC4BHP<br />

200 5 55–250 — 36LPSC4BH 400 37LPSC4BHD 400A/600V 37LPSC4BHF 400 37LPSC4BHP<br />

300 5 55–250 — 36LPUC4BH 600 37LPUC4BHD 600A/600V 37LPUC4BHF 600 37LPUC4BHP<br />

700 6 160–630 — 36MPXC4BH 1600 37MPXC4BHD 1600A/600V 37MPXC4BHF 1200 37MPXC4BHP<br />

15 1 5.5-22 A1 36DUDC5BE 30 37DUDC5BED 30A/600V 37DUDC5BEF 30 37DUDC5BEP<br />

30 (1¾) 10–40 A1 36EUEC5BE 60 37EUEC5BED 60A/600V 37EUEC5BEF 50 37EUEC5BEP<br />

40 2 13–52 B 36FUFC5BE 100 37FUFC5BED 100A/600V 37FUFC5BEF 50 37FUFC5BEP<br />

60 (2½) 25–100 B 36GUGC5BE 100 37GUGC5BED 100A/600V 37GUGC5BEF 100 37GUGC5BEP<br />

75 3 25–100 B 36HUGC5BE 200 37HUGC5BED 200A/600V 37HUGC5BEF 125 37HUGC5BEP<br />

100 (3½) 50–200 B 36IUHC5BE 200 37IUHC5BED 200A/600V 37IUHC5BEF 150 37IUHC5BEP<br />

150 4 50–200 B 36JUHC5BE 400 37JUHC5BED 400A/600V 37JUHC5BEF 250 37JUHC5BEP<br />

200 5 55–250 — 36LPSC5BE 400 37LPSC5BED 400A/600V 37LPSC5BEF 250 37LPSC5BEP<br />

300 5 55–250 — 36LPUC5BE 600 37LPUC5BED 600A/600V 37LPUC5BEF 400 37LPUC5BEP<br />

700 6 160–630 — 37MPXC5BF 1600 37MPXC5BED 1600A/600V 37MPXC5BEF 1600 37MPXC5BEP<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-47


Reduced Voltage Heavy Duty Starters<br />

Wye Delta, Closed Transition with Solid State Overload, Class 36 & 37<br />

Ordering Information<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-150.<br />

Wiring Diagrams see page 17-165.<br />

Replacement Parts see page 17-120.<br />

Coil and Control Voltage<br />

Selection<br />

The coil voltage will always match the<br />

motor voltage. As standard, a CPT is<br />

supplied and 120V control voltage is<br />

utilized. To change to 120V voltage (CPT<br />

not supplied), change the 9th character<br />

to “F”. To change to 24VAC voltage<br />

(CPT not supplied), change the 9th<br />

character to “J”.<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

NEMA 4 Painted Enclosures<br />

Motor<br />

Voltage<br />

200<br />

230<br />

460<br />

575<br />

Max<br />

Hp<br />

Overload Relay<br />

NEMA<br />

Size Amp<br />

(1/2 Size) Range<br />

Frame<br />

Size<br />

Non-Combination<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Combination Non-Fusible<br />

Disconnect Combination Fusible Disconnect Combination Circit Breaker<br />

Disc.<br />

Fuse Clip<br />

Circuit<br />

Amp Catalog List Amp/Volt Catalog List Breaker Catalog List<br />

Rating Number Price $ Rating Number Price $ Amps Number Price $<br />

10 1 10–40 A1 36DUEC6ED 60 37DUEC6EDD 60A/250V 37DUEC6EDF 50 37DUEC6EDP<br />

15 (1¾) 10–40 A1 36EUEC6ED 100 37EUEC6EDD 100A/250V 37EUEC6EDF 100 37EUEC6EDP<br />

20 2 13–52 B 36FUFC6ED 100 37FUFC6EDD 100A/250V 37FUFC6EDF 100 37FUFC6EDP<br />

30 (2½) 25–100 B 36GUGC6ED 200 37GUGC6EDD 200A/250V 37GUGC6EDF 125 37GUGC6EDP<br />

40 3 25–100 B 36HUGC6ED 200 37HUGC6EDD 200A/250V 37HUGC6EDF 150 37HUGC6EDP<br />

50 (3½) 50–200 B 36IUHC6ED 200 37IUHC6EDD 200A/250V 37IUHC6EDF 250 37IUHC6EDP<br />

60 4 50–200 B 36JUHC6ED 400 37JUHC6EDD 400A/250V 37JUHC6EDF 250 37JUHC6EDP<br />

75 5 55–250 — 36LPSC6ED 400 37LPSC6EDD 400A/250V 37LPSC6EDF 400 37LPSC6EDP<br />

150 5 55–250 — 36LPUC6ED 600 37LPUC6EDD 600A/250V 37LPUC6EDF 600 37LPUC6EDP<br />

300 6 160–630 — 36MPXC6ED 1200 37MPXC6EDD 1200A/250V 37MPXC6EDF 1200 37MPXC6EDP<br />

10 1 10–40 A1 36DUEC2EG 60 37DUEC2EGD 60A/250V 37DUEC2EGF 50 37DUEC2EGP<br />

15 (1¾) 10–40 A1 36EUEC2EG 60 37EUEC2EGD 60A/250V 37EUEC2EGF 50 37EUEC2EGP<br />

25 2 13–52 B 36FUFC2EG 100 37FUFC2EGD 100A/250V 37FUFC2EGF 100 37FUFC2EGP<br />

30 (2½) 25–100 B 36GUGC2EG 200 37GUGC2EGD 200A/250V 37GUGC2EGF 100 37GUGC2EGP<br />

50 3 25–100 B 36HUGC2EG 200 37HUGC2EGD 200A/250V 37HUGC2EGF 150 37HUGC2EGP<br />

60 (3½) 50–200 B 36IUHC2EG 200 37IUHC2EGD 200A/250V 37IUHC2EGF 250 37IUHC2EGP<br />

75 4 50–200 B 36JUHC2EG 400 37JUHC2EGD 400A/250V 37JUHC2EGF 250 37JUHC2EGP<br />

100 5 55–250 — 36LPSC2EG 400 37LPSC2EGD 400A/250V 37LPSC2EGF 400 37LPSC2EGP<br />

150 5 55–250 — 36LPUC2EG 600 37LPUC2EGD 600A/250V 37LPUC2EGF 600 37LPUC2EGP<br />

350 6 160–630 — 36MPXC2EG 1200 37MPXC2EGD 1200A/250V 37MPXC2EGF 1200 37MPXC2EGP<br />

15 1 5.5-22 A1 36DUDC4EH 30 37DUDC4EHD 30A/600V 37DUDC4EHF 30 37DUDC4EHP<br />

30 (1¾) 10–40 A1 36EUEC4EH 60 37EUEC4EHD 60A/600V 37EUEC4EHF 50 37EUEC4EHP<br />

40 2 13–52 B 36FUFC4EH 100 37FUFC4EHD 100A/600V 37FUFC4EHF 100 37FUFC4EHP<br />

60 (2½) 25–100 B 36GUGC4EH 200 37GUGC4EHD 200A/600V 37GUGC4EHF 100 37GUGC4EHP<br />

75 3 25–100 B 36HUGC4EH 200 37HUGC4EHD 200A/600V 37HUGC4EHF 125 37HUGC4EHP<br />

100 (3½) 50–200 B 36IUHC4EH 200 37IUHC4EHD 200A/600V 37IUHC4EHF 150 37IUHC4EHP<br />

150 4 50–200 B 36JUHC4EH 400 37JUHC4EHD 400A/600V 37JUHC4EHF 250 37JUHC4EHP<br />

200 5 55–250 — 36LPSC4EH 400 37LPSC4EHD 400A/600V 37LPSC4EHF 400 37LPSC4EHP<br />

300 5 55–250 — 36LPUC4EH 600 37LPUC4EHD 600A/600V 37LPUC4EHF 600 37LPUC4EHP<br />

700 6 160–630 — 36MPXC4EH 1600 37MPXC4EHD 1600A/600V 37MPXC4EHF 1200 37MPXC4EHP<br />

15 1 5.5-22 A1 36DUDC5EE 30 37DUDC5EED 30A/600V 37DUDC5EEF 30 37DUDC5EEP<br />

30 (1¾) 10–40 A1 36EUEC5EE 60 37EUEC5EED 60A/600V 37EUEC5EEF 50 37EUEC5EEP<br />

40 2 13–52 B 36FUFC5EE 100 37FUFC5EED 100A/600V 37FUFC5EEF 50 37FUFC5EEP<br />

60 (2½) 25–100 B 36GUGC5EE 100 37GUGC5EED 100A/600V 37GUGC5EEF 100 37GUGC5EEP<br />

75 3 25–100 B 36HUGC5EE 200 37HUGC5EED 200A/600V 37HUGC5EEF 125 37HUGC5EEP<br />

100 (3½) 50–200 B 36IUHC5EE 200 37IUHC5EED 200A/600V 37IUHC5EEF 150 37IUHC5EEP<br />

150 4 50–200 B 36JUHC5EE 400 37JUHC5EED 400A/600V 37JUHC5EEF 250 37JUHC5EEP<br />

200 5 55–250 — 36LPSC5EE 400 37LPSC5EED 400A/600V 37LPSC5EEF 250 37LPSC5EEP<br />

300 5 55–250 — 36LPUC5EE 600 37LPUC5EED 600A/600V 37LPUC5EEF 400 37LPUC5EEP<br />

700 6 160–630 — 37MPXC5EF 1600 37MPXC5EED 1600A/600V 37MPXC5EEF 1600 37MPXC5EEP<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

17-48<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Reduced Voltage Heavy Duty Starters<br />

Wye Delta, Closed Transition with Solid State Overload, Class 36 & 37<br />

Ordering Information<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-150.<br />

Wiring Diagrams see page 17-165.<br />

Replacement Parts see page 17-120.<br />

Coil and Control Voltage<br />

Selection<br />

The coil voltage will always match the<br />

motor voltage. As standard, a CPT is<br />

supplied and 120V control voltage is<br />

utilized. To change to 120V voltage (CPT<br />

not supplied), change the 9th character<br />

to “F”. To change to 24VAC voltage<br />

(CPT not supplied), change the 9th<br />

character to “J”.<br />

NEMA 4/4X Stainless Steel Enclosures<br />

Motor<br />

Voltage<br />

200<br />

230<br />

460<br />

575<br />

Max<br />

Hp<br />

Overload Relay<br />

NEMA<br />

Size Amp<br />

(1/2 Size) Range<br />

Frame<br />

Size<br />

Non-Combination<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Combination Non-Fusible<br />

Disconnect Combination Fusible Disconnect Combination Circit Breaker<br />

Disc.<br />

Fuse Clip<br />

Circuit<br />

Amp Catalog List Amp/Volt Catalog List Breaker Catalog List<br />

Rating Number Price $ Rating Number Price $ Amps Number Price $<br />

10 1 10–40 A1 36DUEC6WD 60 37DUEC6WDD 60A/250V 37DUEC6WDF 50 37DUEC6WDP<br />

15 (1¾) 10–40 A1 36EUEC6WD 100 37EUEC6WDD 100A/250V 37EUEC6WDF 100 37EUEC6WDP<br />

20 2 13–52 B 36FUFC6WD 100 37FUFC6WDD 100A/250V 37FUFC6WDF 100 37FUFC6WDP<br />

30 (2½) 25–100 B 36GUGC6WD 200 37GUGC6WDD 200A/250V 37GUGC6WDF 125 37GUGC6WDP<br />

40 3 25–100 B 36HUGC6WD 200 37HUGC6WDD 200A/250V 37HUGC6WDF 150 37HUGC6WDP<br />

50 (3½) 50–200 B 36IUHC6WD 200 37IUHC6WDD 200A/250V 37IUHC6WDF 250 37IUHC6WDP<br />

60 4 50–200 B 36JUHC6WD 400 37JUHC6WDD 400A/250V 37JUHC6WDF 250 37JUHC6WDP<br />

10 1 10–40 A1 36DUEC2WG 60 37DUEC2WGD 60A/250V 37DUEC2WGF 50 37DUEC2WGP<br />

15 (1¾) 10–40 A1 36EUEC2WG 60 37EUEC2WGD 60A/250V 37EUEC2WGF 50 37EUEC2WGP<br />

25 2 13–52 B 36FUFC2WG 100 37FUFC2WGD 100A/250V 37FUFC2WGF 100 37FUFC2WGP<br />

30 (2½) 25–100 B 36GUGC2WG 200 37GUGC2WGD 200A/250V 37GUGC2WGF 100 37GUGC2WGP<br />

50 3 25–100 B 36HUGC2WG 200 37HUGC2WGD 200A/250V 37HUGC2WGF 150 37HUGC2WGP<br />

60 (3½) 50–200 B 36IUHC2WG 200 37IUHC2WGD 200A/250V 37IUHC2WGF 250 37IUHC2WGP<br />

75 4 50–200 B 36JUHC2WG 400 37JUHC2WGD 400A/250V 37JUHC2WGF 250 37JUHC2WGP<br />

15 1 5.5-22 A1 36DUDC4WH 30 37DUDC4WHD 30A/600V 37DUDC4WHF 30 37DUDC4WHP<br />

30 (1¾) 10–40 A1 36EUEC4WH 60 37EUEC4WHD 60A/600V 37EUEC4WHF 50 37EUEC4WHP<br />

40 2 13–52 B 36FUFC4WH 100 37FUFC4WHD 100A/600V 37FUFC4WHF 100 37FUFC4WHP<br />

60 (2½) 25–100 B 36GUGC4WH 200 37GUGC4WHD 200A/600V 37GUGC4WHF 100 37GUGC4WHP<br />

75 3 25–100 B 36HUGC4WH 200 37HUGC4WHD 200A/600V 37HUGC4WHF 125 37HUGC4WHP<br />

100 (3½) 50–200 B 36IUHC4WH 200 37IUHC4WHD 200A/600V 37IUHC4WHF 150 37IUHC4WHP<br />

150 4 50–200 B 36JUHC4WH 400 37JUHC4WHD 400A/600V 37JUHC4WHF 250 37JUHC4WHP<br />

15 1 5.5-22 A1 36DUDC5WE 30 37DUDC5WED 30A/600V 37DUDC5WEF 30 37DUDC5WEP<br />

30 (1¾) 10–40 A1 36EUEC5WE 60 37EUEC5WED 60A/600V 37EUEC5WEF 50 37EUEC5WEP<br />

40 2 13–52 B 36FUFC5WE 100 37FUFC5WED 100A/600V 37FUFC5WEF 50 37FUFC5WEP<br />

60 (2½) 25–100 B 36GUGC5WE 100 37GUGC5WED 100A/600V 37GUGC5WEF 100 37GUGC5WEP<br />

75 3 25–100 B 36HUGC5WE 200 37HUGC5WED 200A/600V 37HUGC5WEF 125 37HUGC5WEP<br />

100 (3½) 50–200 B 36IUHC5WE 200 37IUHC5WED 200A/600V 37IUHC5WEF 150 37IUHC5WEP<br />

150 4 50–200 B 36JUHC5WE 400 37JUHC5WED 400A/600V 37JUHC5WEF 250 37JUHC5WEP<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-49


Reduced Voltage Heavy Duty Starters<br />

Wye Delta, Closed Transition with Solid State Overload, Class 36 & 37<br />

Ordering Information<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-150.<br />

Wiring Diagrams see page 17-165.<br />

Replacement Parts see page 17-120.<br />

Revised on 08/31/18<br />

Coil and Control Voltage<br />

Selection<br />

The coil voltage will always match the<br />

motor voltage. As standard, a CPT is<br />

supplied and 120V control voltage is<br />

utilized. To change to 120V voltage (CPT<br />

not supplied), change the 9th character<br />

to “F”. To change to 24VAC voltage<br />

(CPT not supplied), change the 9th<br />

character to “J”.<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

NEMA 12, NEMA 3/3R<br />

Motor<br />

Voltage<br />

200<br />

230<br />

460<br />

575<br />

Max<br />

Hp<br />

Overload Relay<br />

NEMA<br />

Size Amp<br />

(1/2 Size) Range<br />

Frame<br />

Size<br />

Non-Combination<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Combination Non-Fusible<br />

Disconnect Combination Fusible Disconnect Combination Circit Breaker<br />

Disc.<br />

Fuse Clip<br />

Circuit<br />

Amp Catalog List Amp/Volt Catalog List Breaker Catalog List<br />

Rating Number Price $ Rating Number Price $ Amps Number Price $<br />

10 1 10–40 A1 36DUEC6ND 60 37DUEC6NDD 60A/250V 37DUEC6NDF 50 37DUEC6NDP<br />

15 (1¾) 10–40 A1 36EUEC6ND 100 37EUEC6NDD 100A/250V 37EUEC6NDF 100 37EUEC6NDP<br />

20 2 13–52 B 36FUFC6ND 100 37FUFC6NDD 100A/250V 37FUFC6NDF 100 37FUFC6NDP<br />

30 (2½) 25–100 B 36GUGC6ND 200 37GUGC6NDD 200A/250V 37GUGC6NDF 125 37GUGC6NDP<br />

40 3 25–100 B 36HUGC6ND 200 37HUGC6NDD 200A/250V 37HUGC6NDF 150 37HUGC6NDP<br />

50 (3½) 50–200 B 36IUHC6ND 200 37IUHC6NDD 200A/250V 37IUHC6NDF 250 37IUHC6NDP<br />

60 4 50–200 B 36JUHC6ND 400 37JUHC6NDD 400A/250V 37JUHC6NDF 250 37JUHC6NDP<br />

75 5 55–250 — 36LPSC6ND 400 37LPSC6NDD 400A/250V 37LPSC6NDF 400 37LPSC6NDP<br />

150 5 55–250 — 36LPUC6ND 600 37LPUC6NDD 600A/250V 37LPUC6NDF 600 37LPUC6NDP<br />

300 6 160–630 — 36MPXC6ND 1200 37MPXC6NDD 1200A/250V 37MPXC6NDF 1200 37MPXC6NDP<br />

10 1 10–40 A1 36DUEC2NG 60 37DUEC2NGD 60A/250V 37DUEC2NGF 50 37DUEC2NGP<br />

15 (1¾) 10–40 A1 36EUEC2NG 60 37EUEC2NGD 60A/250V 37EUEC2NGF 50 37EUEC2NGP<br />

25 2 13–52 B 36FUFC2NG 100 37FUFC2NGD 100A/250V 37FUFC2NGF 100 37FUFC2NGP<br />

30 (2½) 25–100 B 36GUGC2NG 200 37GUGC2NGD 200A/250V 37GUGC2NGF 100 37GUGC2NGP<br />

50 3 25–100 B 36HUGC2NG 200 37HUGC2NGD 200A/250V 37HUGC2NGF 150 37HUGC2NGP<br />

60 (3½) 50–200 B 36IUHC2NG 200 37IUHC2NGD 200A/250V 37IUHC2NGF 250 37IUHC2NGP<br />

75 4 50–200 B 36JUHC2NG 400 37JUHC2NGD 400A/250V 37JUHC2NGF 250 37JUHC2NGP<br />

100 5 55–250 — 36LPSC2NG 400 37LPSC2NGD 400A/250V 37LPSC2NGF 400 37LPSC2NGP<br />

150 5 55–250 — 36LPUC2NG 600 37LPUC2NGD 600A/250V 37LPUC2NGF 600 37LPUC2NGP<br />

350 6 160–630 — 36MPXC2NG 1200 37MPXC2NGD 1200A/250V 37MPXC2NGF 1200 37MPXC2NGP<br />

15 1 5.5-22 A1 36DUDC4NH 30 37DUDC4NHD 30A/600V 37DUDC4NHF 30 37DUDC4NHP<br />

30 (1¾) 10–40 A1 36EUEC4NH 60 37EUEC4NHD 60A/600V 37EUEC4NHF 50 37EUEC4NHP<br />

40 2 13–52 B 36FUFC4NH 100 37FUFC4NHD 100A/600V 37FUFC4NHF 100 37FUFC4NHP<br />

60 (2½) 25–100 B 36GUGC4NH 200 37GUGC4NHD 200A/600V 37GUGC4NHF 100 37GUGC4NHP<br />

75 3 25–100 B 36HUGC4NH 200 37HUGC4NHD 200A/600V 37HUGC4NHF 125 37HUGC4NHP<br />

100 (3½) 50–200 B 36IUHC4NH 200 37IUHC4NHD 200A/600V 37IUHC4NHF 150 37IUHC4NHP<br />

150 4 50–200 B 36JUHC4NH 400 37JUHC4NHD 400A/600V 37JUHC4NHF 250 37JUHC4NHP<br />

200 5 55–250 — 36LPSC4NH 400 37LPSC4NHD 400A/600V 37LPSC4NHF 400 37LPSC4NHP<br />

300 5 55–250 — 36LPUC4NH 600 37LPUC4NHD 600A/600V 37LPUC4NHF 600 37LPUC4NHP<br />

700 6 160–630 — 36MPXC4NH 1600 37MPXC4NHD 1600A/600V 37MPXC4NHF 1200 37MPXC4NHP<br />

15 1 5.5-22 A1 36DUDC5NE 30 37DUDC5NED 30A/600V 37DUDC5NEF 30 37DUDC5NEP<br />

30 (1¾) 10–40 A1 36EUEC5NE 60 37EUEC5NED 60A/600V 37EUEC5NEF 50 37EUEC5NEP<br />

40 2 13–52 B 36FUFC5NE 100 37FUFC5NED 100A/600V 37FUFC5NEF 50 37FUFC5NEP<br />

60 (2½) 25–100 B 36GUGC5NE 100 37GUGC5NED 100A/600V 37GUGC5NEF 100 37GUGC5NEP<br />

75 3 25–100 B 36HUGC5NE 200 37HUGC5NED 200A/600V 37HUGC5NEF 125 37HUGC5NEP<br />

100 (3½) 50–200 B 36IUHC5NE 200 37IUHC5NED 200A/600V 37IUHC5NEF 150 37IUHC5NEP<br />

150 4 50–200 B 36JUHC5NE 400 37JUHC5NED 400A/600V 37JUHC5NEF 250 37JUHC5NEP<br />

200 5 55–250 — 36LPSC5NE 400 37LPSC5NED 400A/600V 37LPSC5NEF 250 37LPSC5NEP<br />

300 5 55–250 — 36LPUC5NE 600 37LPUC5NED 600A/600V 37LPUC5NEF 400 37LPUC5NEP<br />

700 6 160–630 — 37MPXC5NF 1600 37MPXC5NED 1600A/600V 37MPXC5NEF 1600 37MPXC5NEP<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

17-50<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Heavy Duty Contactors<br />

3-Phase, Class 40<br />

Revised on 03/31/20<br />

Selection<br />

Ordering Information<br />

Replace the (*) with a letter from the coil table. Dual voltage coils are<br />

wired on high voltage unless specified on order.<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see pages 17-131 open and 17-141 enclosed.<br />

Wiring Diagrams see page 17-166.<br />

Replacement Parts see page 17-120.<br />

Coil Table<br />

60Hz Voltage<br />

Letter<br />

24 J<br />

120 F<br />

110–120/220–240 a A<br />

200–208 D<br />

220–240 G<br />

277 L<br />

220–240/440–480 a C<br />

440–480 H<br />

575–600 E<br />

For other voltages and frequencies,<br />

see Factory Modifications page 17-114.<br />

Open Type & Standard Width Enclosure, 3-Phase, 3-Pole<br />

Max Hp<br />

Enclosure<br />

Open Type NEMA 1<br />

General Purpose<br />

Contactor<br />

Amp<br />

Rating<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

304 Stainless Steel<br />

NEMA 4X Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

200 230 460 575<br />

NEMA Half Catalog List Catalog List Catalog List Catalog List Catalog<br />

Volts Volts Volts Volts<br />

Size Size Number Price $ Number Price $ Number Price $ Number Price $ Number<br />

1 1 ⁄2 1 1 ⁄2 2 2 9 00 — 40BP32A* 40BP32B* Use Size 0 — Use Size 0 — Use Size 0 —<br />

3 3 5 5 18 0 — 40CP32A* 40CP32B* 40CP32W* 40CP32F* 40CP320*<br />

7 1 ⁄2 7 1 ⁄2 10 10 27 1 — 40DP32A* 40DP32B* 40DP32W* 40DP32F* 40DP320*<br />

10 10 15 15 40 — 1 3 ⁄4 40EP32A* 40EP32B* 40EP32W* 40EP32F* 40EP320*<br />

10 15 25 25 45 2 — 40FP32A* 40FP32B* 40FP32W* 40FP32F* 40FP320*<br />

15 20 30 30 60 — 2 1 ⁄2 40GP32A* 40GP32B* 40GP32W* 40GP32F* 40GP320*<br />

25 30 50 50 90 3 — 40HP32A* 40HP32B* 40HP32W* 40HP32F* 40HP320*<br />

30 40 75 75 115 — 3 1 ⁄2 40IP32A* 40IP32B* 40IP32W* 40IP32F* 40IP320*<br />

40 50 100 100 135 4 — 40JG32A* 40JG32B* 40JG32W* 40JG32F* 40JG320*<br />

75 100 200 200 270 5 — 40LP32A* 40LP32B* — — — — 40LP320*<br />

150 200 400 400 540 6 — 40MP32A* 40MP32B* — — — — 40MP320*<br />

— 300 600 600 810 7 — 40NH32A* 40NH32B* — — — — 40NH320*<br />

— 450 900 900 1215 8 — 40PH32A* 40PH32B* — — — — 40PH320*<br />

Extra Wide Enclosure, 3-Phase, 3-Pole<br />

Max Hp<br />

Contactor<br />

Amp<br />

Rating<br />

Enclosure<br />

NEMA 1 <br />

General Purpose<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

304 Stainless Steel<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

200<br />

Volts<br />

230<br />

Volts<br />

460<br />

Volts<br />

575<br />

Volts<br />

NEMA<br />

Size<br />

Half<br />

Size<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

1 1 ⁄2 1 1 ⁄2 2 2 9 00 — 40BP82B* Use Size 0 — Use Size 0 —<br />

3 3 5 5 18 0 — 40CP82B* 40CP82W* 40CP820*<br />

7 1 ⁄2 7 1 ⁄2 10 10 27 1 — 40DP82B* 40DP82W* 40DP820*<br />

10 10 15 15 40 — 1 3 / 4 40EP82B* 40EP82W* 40EP820*<br />

10 15 25 25 45 2 — 40FP82B* 40FP82W* 40FP820*<br />

15 20 30 30 60 — 2 1 / 2 40GP82B* 40GP82W* 40GP820*<br />

25 30 50 50 90 3 — 40HP82B* 40HP82W* 40HP820*<br />

30 40 75 75 115 — 3 1 / 2 40IP82B* 40IP82W* 40IP820*<br />

40 50 100 100 135 4 — 40JG82B* 40JG82W* 40JG820*<br />

List<br />

Price $<br />

List<br />

Price $<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Note: Hp’s shown above are based on the overload<br />

amp range for the FLA’s (per the National Electric<br />

Code) of typical industrial motors. All starter sizes<br />

carry one maximum Hp rating.<br />

a Dual voltage coils not available in size 5-8 starters.<br />

Only available<br />

F coil 100-250V AC 50/60Hz, or DC<br />

H coil 150-500V AC 50/60Hz, or DC<br />

Only available<br />

F coil100-250V AC 50/60Hz, or DC<br />

<br />

Standard Auxiliary Contacts<br />

Type Size (3rd Character) Configuration Internal / External<br />

B Thru E 1N.O. Internal<br />

All FVNR F Thru J 1N.O. External<br />

Starters &<br />

Contactors L Thru M 2N.O., 2N.C. External<br />

N Thru P 1N.O., 1N.C. External<br />

Lugs are not included, refer to page 17-106.<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-51


Heavy Duty Contactors<br />

Single Phase, 4-Pole & Vacuum, Class 40<br />

Revised on 03/31/20<br />

Selection<br />

Ordering Information<br />

Replace the (*) with a letter from the coil table.<br />

Dual voltage coils are wired on high voltage unless<br />

specified on order.<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see pages 17-131 open and<br />

17-141 enclosed.<br />

Wiring Diagrams see page 17-166.<br />

Replacement Parts see page 17-120.<br />

Coil Table<br />

60Hz Voltage<br />

Letter<br />

24 J<br />

120 F<br />

110–120/220–240 a A<br />

200–208 D<br />

220–240 G<br />

277 L<br />

220–240/440–480 a C<br />

440–480 H<br />

575–600 E<br />

For other voltages and frequencies,<br />

see Factory Modifications page 17-114.<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Open Type & Standard Width Enclosure, Single Phase, 2-Pole c<br />

Max Hp<br />

Enclosure<br />

Open Type d NEMA 1<br />

General Purpose<br />

208/<br />

230<br />

Volts<br />

Contactor<br />

Amp<br />

Rating<br />

NEMA 4/4X<br />

Stainless<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

NEMA 4X<br />

Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

115<br />

Volts<br />

NEMA<br />

Size<br />

Half<br />

Size<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

1<br />

⁄3 1 9 00 — 40BP12A* 40BP12B* Use Size 0 — Use Size 0 — Use Size 0 —<br />

1 2 18 0 — 40CP12A* 40CP12B* 40CP12W* 40CP12F* 40CP120*<br />

2 3 27 1 — 40DP12A* 40DP12B* 40DP12W* 40DP12F* 40DP120*<br />

3 5 35 1P — 40EP12A* 40EP12B* 40EP12W* 40EP12F* 40EP120*<br />

3 7 1 ⁄2 45 2 — 40FP12A* 40FP12B* 40FP12W* 40FP12F* 40FP120*<br />

5 10 60 — 2 1 ⁄2 40GP12A* 40GP12B* 40GP12W* 40GP12F* 40GP120*<br />

7 1 ⁄2 15 90 3 — 40HP12A* 40HP12B* 40HP12W* 40HP12F* 40HP120*<br />

Open Type & Standard Width Enclosure, 4-Pole<br />

Max Hp<br />

Enclosure<br />

Open Type NEMA 1<br />

General Purpose<br />

200<br />

Volts<br />

Contactor<br />

Amp<br />

Rating<br />

NEMA 4/4X<br />

Stainless<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

Catalog List<br />

Number Price $<br />

NEMA 4X<br />

Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

Catalog List<br />

Number Price $<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

230<br />

Volts<br />

460<br />

Volts<br />

575<br />

Volts<br />

NEMA<br />

Size<br />

Half<br />

Size<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

1<br />

⁄3 1 1 ⁄2 2 2 9 00 — 40BP22A* 40BP22B* Use Size 0 — Use Size 0 — Use Size 0 —<br />

2 3 5 5 18 0 — 40CP22A* 40CP22B* 40CP22W* 40CP22F* 40CP220*<br />

3 7 1 ⁄2 10 10 27 1 — 40DP22A* 40DP22B* 40DP22W* 40DP22F* 40DP220*<br />

5 10 15 15 40 — 1 3 ⁄4 40EP22A* 40EP22B* 40EP22W* 40EP22F* 40EP220*<br />

List<br />

Price $<br />

Vacuum Contactors, 3-Phase, 3-Pole a<br />

Max Hp<br />

Contactor<br />

Amp<br />

NEMA<br />

Open Type<br />

200V 230V 460V 575V Rating Size Catalog Number List Price $<br />

40 50 100 100 135 4 40JV32A*<br />

75 100 200 200 270 5 40LV32A*<br />

150 200 400 400 540 6 40MV32A*<br />

Note: Hp’s shown above are based on the overload amp<br />

range for the FLA’s (per the National Electric Code)<br />

of typical industrial motors. All starter sizes carry<br />

one maximum Hp rating.<br />

a Dual voltage coils not available for vacuum contactors.<br />

Refer to Page 17-114 for a complete list of available coil voltages.<br />

To order single phase contactor in an extra wide enclosure,<br />

order the enclosure kit from Page 17-111 and the open<br />

style contactor as separate items.<br />

Coils D, F, or G will be wired for incoming voltage.<br />

J coil will be wired for separate source. Coils E, H,<br />

and L do not apply to single phase starters.<br />

1 NO Auxiliary.<br />

17-52<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Reversing Heavy Duty Contactors<br />

Class 43<br />

Revised on 03/31/20<br />

Selection<br />

Ordering Information<br />

Replace the (*) with a letter from the coil table. Dual voltage coils are<br />

wired on high voltage unless specified on order.<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see pages 17-132 open and 17-145 enclosed.<br />

Wiring Diagrams see page 17-166.<br />

Replacement Parts see page 17-120.<br />

Coil Table<br />

60Hz Voltage<br />

Letter<br />

24 J<br />

120 F<br />

110–120/220–240 a A<br />

200–208 D<br />

220–240 G<br />

277 L<br />

220–240/440–480 a C<br />

440–480 H<br />

575–600 E<br />

For other voltages and frequencies,<br />

see Factory Modifications page 17-114.<br />

Open Type & Standard Width Enclosure, 3-Phase, 3-Pole<br />

Max Hp<br />

Enclosure<br />

Open Type NEMA 1<br />

General Purpose<br />

Contactor<br />

Amp<br />

Rating<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

304 Stainless Steel<br />

NEMA 4X Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

200<br />

Volts<br />

230<br />

Volts<br />

460<br />

Volts<br />

575<br />

Volts<br />

NEMA<br />

Size<br />

Half<br />

Size<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

1<br />

⁄2<br />

1<br />

⁄2 2 2 9 00 — 43BP32A* 43BP32B* Use Size 0 — Use Size 0 — Use Size 0 —<br />

3 3 5 5 18 0 — 43CP32A* 43CP32B* 43CP32W* 43CP32F* 43CP320*<br />

7 1 ⁄2 7 1 ⁄2 10 10 27 1 — 43DP32A* 43DP32B* 43DP32W* 43DP32F* 43DP320*<br />

10 10 15 15 40 — 1 3 ⁄4 43EP32A* 43EP32B* 43EP32W* 43EP32F* 43EP320*<br />

10 15 25 25 45 2 — 43FP32A* 43FP32B* 43FP32W* 43FP32F* 43FP320*<br />

15 20 30 30 60 — 2 1 ⁄2 43GP32A* 43GP32B* 43GP32W* 43GP32F* 43GP320*<br />

25 30 50 50 90 3 — 43HP32A* 43HP32B* 43HP32W* 43HP32F* 43HP320*<br />

30 40 75 75 115 — 3 1 ⁄2 43IP32A* 43IP32B* 43IP32W* 43IP32F* 43IP320*<br />

40 50 100 100 135 4 — 43JG32A* 43JG32B* 43JG32W* 43JG32F* 43JG320*<br />

75 100 200 200 270 5 — 43LP32A* 43LP32B* — — — — 43LP320*<br />

100 200 400 400 540 6 — 43MP32A* 43MP32B* — — — — 43MP320*<br />

— 300 600 600 810 7 — 43NH32A* 43NH32B* — — — — 43NH320*<br />

— 450 900 900 1215 8 — 43PH32A* — — — — — — —<br />

Open Type & Standard Width Enclosure, Single Phase, 3-Wire, 2-Pole <br />

Max Hp<br />

Enclosure<br />

208/<br />

230<br />

Volts<br />

Contactor<br />

Amp<br />

Rating<br />

Open Type NEMA 1<br />

General Purpose<br />

NEMA 4/4X<br />

Stainless<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

Catalog List<br />

Number Price $<br />

NEMA 4X<br />

Fiberglass<br />

Watertight, Dust-tight<br />

Corrosion Resistant<br />

Catalog List<br />

Number Price $<br />

NEMA 3/3R/4/12<br />

Watertight, Dust-tight,<br />

Weatherproof<br />

115<br />

Volts<br />

NEMA<br />

Size<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

1<br />

⁄3 1 9 00 43BP12A* 43BP12B* Use Size 0 — Use Size 0 — Use Size 0 —<br />

1 2 18 0 43CP12A* 43CP12B* 43CP12W* 43CP12F* 43CP120*<br />

2 3 27 1 43DP12A* 43DP12B* 43DP12W* 43DP12F* 43DP120*<br />

3 5 35 1P 43EP12A* 43EP12B* 43EP12W* 43EP12F* 43EP120*<br />

List<br />

Price $<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Note: Hp’s shown above are based on the overload<br />

amp range for the FLA’s (per the National Electric<br />

Code) of typical industrial motors. All starter sizes<br />

carry one maximum Hp rating.<br />

a Dual voltage coils not available in size 5–8 starters.<br />

Coils D, F, or G will be wired for incoming voltage. J<br />

coil will be wired for separate source. Coils E, H, and L<br />

do not apply to single phase starters.<br />

Only available<br />

F coil 100-250V AC 50/60Hz, or DC<br />

H coil 150-500V AC 50/60Hz, or DC<br />

Only available<br />

F coil 100-250V AC 50/60Hz, or DC<br />

Auxiliary contacts<br />

43B-43E 4th pole built-in<br />

43F-43J 2 NO & 2 NC<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-53


Definite Purpose Control<br />

Class 42 & 45<br />

Revised on 10/31/19<br />

Product Nomenclature<br />

Class 42 & 45 Product Nomenclature<br />

Class 45<br />

DP Contactor<br />

Information shown on nomenclature sheets is for reference only to identify devices from existing catalog numbers.<br />

This information is not to be used for the creation of new catalog numbers.<br />

45 C G 2 0 A J A<br />

CLASS<br />

45<br />

DP Contactor<br />

AMP<br />

RATING MODEL POWER POLES NC POWER POLES ENCLOSURE COIL STD FEATURES<br />

E 30<br />

G 40<br />

G<br />

1 1 power pole<br />

2 2 power poles<br />

0 None A Open F 120V, 60 HZ<br />

110V, 50 HZ<br />

G 208-240V, 60 HZ<br />

190-220V, 50 HZ<br />

H 440-480V, 60 HZ<br />

380-440V, 50 HZ<br />

J 24V, 60 HZ<br />

24V, 50 HZ<br />

L 277V, 60 HZ<br />

A Jumper Bar<br />

* Class F coil standard.<br />

Binding head screws<br />

(30A)/ lugs (40A) and<br />

quad quick connect<br />

standard.<br />

* Contact cover<br />

comes standard.<br />

Class 42<br />

DP Contactor<br />

Information shown on nomenclature sheets is for reference only to identify devices from existing catalog numbers.<br />

This information is not to be used for the creation of new catalog numbers.<br />

17<br />

CONTROL<br />

PRODUCTS<br />

42 B F 3 5 A J<br />

CLASS<br />

42<br />

DP Contactor<br />

AMP<br />

RATING MODEL POWER POLES CONTROL CIRCUIT ENCLOSURE COIL<br />

B 30<br />

C 40<br />

D 50<br />

E 60<br />

F 75<br />

G 90<br />

F<br />

E*<br />

*75-90 amp<br />

only<br />

1 2 power poles<br />

3 3 power poles<br />

5 Without auxiliary<br />

contact<br />

A Open<br />

F 110V, 50 HZ<br />

120V, 60 HZ<br />

G 190-220V, 50 HZ<br />

208-240V, 60 HZ<br />

J 24V, 50 HZ<br />

24V, 60 HZ<br />

H 380-440V, 50 HZ<br />

440-480V, 60 HZ<br />

L 277V, 60 HZ<br />

17-54<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Definite Purpose Control<br />

Class 42 & 45<br />

Revised on 10/31/19<br />

General Application<br />

Class 45<br />

­<br />

45EG10AJA 45GG10AJA<br />

45EG20AJ 45GG20AJ<br />

Features<br />

n Power Terminations:<br />

• Quad Quick Connects<br />

• 30A: Screws<br />

• ≥40A: Box Lugs<br />

n Compact Size<br />

n Durable Metal Back Plate<br />

n Enclosed Body and Coil<br />

n One Pole Version Includes Shunt Bar<br />

n Quiet Operation<br />

n Weld-Resistant Silver Cadmium Oxide Contacts<br />

n Visual Contact Position Indication<br />

n Class F Coil Insulation<br />

Class 42<br />

­<br />

17 CONTROL<br />

PRODUCTS<br />

42BF35AJ 42CF35AJ<br />

42CF15AJ 42FE35AJ<br />

Features<br />

n Power Terminations:<br />

• Quick Connects<br />

• 30A: Screws<br />

• ≥40A: Box Lugs<br />

n Compact Size<br />

n Durable Metal Back Plate<br />

n Quiet Operation<br />

n Weld-Resistant Silver Cadmium Oxide Contacts<br />

n Visual Contact Position Indication<br />

n Class F Coil Insulation<br />

n Snap-On Auxiliary Contacts<br />

n Replacement Coils Available<br />

Approvals & Standards:<br />

n<br />

n ARI 780 & 790<br />

n Canadian Heater Rated<br />

n SCCR 600 VAC<br />

n UL File E14900<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-55


Definite Purpose Control<br />

Class 42 & 45<br />

Revised on 10/31/19<br />

Selection<br />

Ordering Information<br />

Use complete catalog number.<br />

Replace the (●) with letter from<br />

the coil table on this page<br />

For additional information see<br />

www.usa.siemens.com/controls<br />

Coil Selection (●)<br />

60Hz Voltage 50Hz Voltage Letter<br />

24 24 J<br />

110–120 110 F<br />

208–240 190–220 G<br />

277 240 L<br />

440–480 380–440 H a<br />

a Not available on Class 42 2-pole units<br />

Contactors<br />

Class 45 Contactors<br />

Locked Rotor Amps<br />

Non<br />

FLA<br />

240V 277V 480V 600V<br />

Inductive<br />

Amps Poles<br />

Catalog<br />

Number<br />

30 180 180 — — 40 1 45EG10A●A<br />

40 240 240 — — 50 1 45GG10A●A<br />

30 180 — 150 120 40 2 45EG20A●<br />

40 240 — 200 160 50 2 45GG20A●<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Class 42 Contactors<br />

FLA<br />

Locked Rotor Amps<br />

240V 480V 600V<br />

Non<br />

Inductive<br />

Amps<br />

Horsepower<br />

1 PH 3 PH<br />

120 V 240 V 240V 480V 600V<br />

Poles<br />

Catalog<br />

Number<br />

30 180 150 120 40 2 3 7.5 — — 2 42BF15A●<br />

40 240 200 160 50 3 5 10 — — 2 42CF15A●<br />

30 180 150 120 40 — 3 7.5 10 15 3 42BF35A●<br />

40 240 200 160 50 — 5 10 15 20 3 42CF35A●<br />

50 300 250 200 63 — 5 15 20 25 3 42DF35A●<br />

60 360 300 240 75 — 7.5 20 25 30 3 42EF35A●<br />

75 450 375 300 94 — 15 25 40 40 3 42FE35A●<br />

90 540 450 360 120 — 15 30 50 50 3 42GE35A●<br />

Accessories<br />

Auxiliary Contacts<br />

Description Class Contactor FLA Auxiliary Contact Ratings<br />

Snap-on Side Mounted<br />

Auxiliary Contacts<br />

49ACR0<br />

42 30-60<br />

42 75-90<br />

NEMA A600<br />

10A 600VAC<br />

11A 1/2HP 125-250VAC,<br />

0.6A 125VDC, 0.3A 250VDC<br />

NEMA A600<br />

10A 600V<br />

11A 1/2HP 125-250VAC,<br />

0.6A 125VDC, 0.3A 250VDC<br />

Auxiliary<br />

Contacts<br />

Catalog<br />

Number<br />

1 NO 49ACR0<br />

1 NC 49ACRC<br />

1 NO & 1 NC 49ACR6<br />

2 NO 49ACR7<br />

2 NC 49ACR8<br />

1 SPDT 49D36098001<br />

2 SPDT 49D36098003<br />

1 NO 49D22125001<br />

1 NC 49D22125002<br />

1 SPDT 49CE42SPDT<br />

17-56<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Definite Purpose Control<br />

Class 42 & 45<br />

Revised on 10/31/19<br />

Replacement Parts<br />

Replacement Coils<br />

Class 42<br />

Description<br />

Third<br />

Character<br />

of Cat. No.<br />

B, C F<br />

Fourth<br />

Character<br />

of Cat. No. Volts 60 Hz Volts 50 Hz<br />

Catalog<br />

Number<br />

24 24 75D70646AJ<br />

110-120 110 75D70646AF<br />

208-240 190-220 75D70646AG<br />

277 240 75D70646AL<br />

440-480 380-440 75D70646AH<br />

75D70646AF<br />

D, E F<br />

24 24 75D70550AJ<br />

110-120 110 75D70550AF<br />

208-240 190-220 75D70550AG<br />

277 240 75D70550AL<br />

440-480 380-440 75D70550AH<br />

75D70550AF<br />

F, G E<br />

24 24 75D54772AJ<br />

110-120 110 75D54772AF<br />

208-240 190-220 75D54772AG<br />

277 240 75D54772AL<br />

440-480 380-440 75D54772AH<br />

75D54772AF<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-57


Definite Purpose Control<br />

Class 42 & 45<br />

Revised on 10/31/19<br />

Cross Reference<br />

Catalog Numbers<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Poles<br />

Amps<br />

Coil<br />

Volts SIEMENS ABB<br />

Allen<br />

Bradley<br />

Arrow<br />

Hart<br />

Eaton Cutler<br />

Hammer Fasco<br />

General<br />

Electric<br />

Joslyn<br />

Clark<br />

Products<br />

Unlimited Square D Steveco<br />

1 30 24 45EG10AJA DP30C1P-F 400-DP30NJ1 C301NU10 C25CNB130T 1S30-A CR453CC3HAA A77-306653A-3 3100-15Q2 8910DP31V14 94388<br />

120 45EG10AFA DP30C1P-1 400-DP30ND1 C301NU20 C25CNB130A 1S30-B CR453CC3AAA A77-306653A-1 3100-15T2 8910DP31V02 94389<br />

208/240 45EG10AGA DP30C1P-2 400-DP30NA1 C301NU30 C25CNB130B 1S30-C CR453CC3BAA A77-3066531-2 3100-15U2 8910DP31V09 94390<br />

40 24 45GG10AJA — — — C25CNB140T — — — 3100-15Q19 8910DP41V14 —<br />

120 45GG10AFA — — — C25CNB140A — — — 3100-15T19 8910DP41V02 —<br />

208/240 45GG10AGA — — — C25CNB140B — — — 3100-15U19 8910DP41V09 —<br />

2 30 24 45EG20AJ — 400-DP30NJ2 C302U10 C25BNB230T 2S30-A CR453CC2HAA A77-306657A-3 3100-20Q6 8910DPA32V14 90244<br />

120 45EG20AF — 400-DP30ND2 C302U20 C25BNB230A 2S30-B CR453CC2AAA A77-306657A-1 3100-20T6 8910DPA32V02 90245<br />

208/240 45EG20AG — 400-DP30NA2 C302U30 C25BNB230B 2S30-C CR453CC2BAA A77-306657A-2 3100-20U6 8910DPA32V09 90246<br />

277 45EG20AL — 400-DP30NF2 C302050 C25BNB230H — CR453CC2FAA — 3100-20V6 8910DPA32V04 —<br />

40 24 45GG20AJ — — CA01NU10 C25BNB240T — CR453CE2HBB — 3100-20Q18 8910DP42V14 —<br />

120 45GG20AF — — CA01NU20 C25BNB240A — CR453CE2ABB — 3100-20T18 8910DP42V02 —<br />

208/240 45GG20AG — — CA01NU30 C25BNB240B — CR453CE2BBB — 3100-20U18 8910DP42V09 —<br />

3 30 24 42BF35AJ DP30C3P-F 400-DP30NJ3 ACC330UM10 C25DND330T 3M30-A CR453AC3HAA A77-309044A-3 3100-30Q9 8910DPA33V14 90163<br />

120 42BF35AF DP30C3P-1 400-DP30ND3 ACC330UM20 C25DND330A 3M30-B CR453AC3AAA A77-309044A-1 3100-30T99 8910DPA33V02 90164<br />

208/240 42BF35AG DP30C3P-2 400-DP30NA3 ACC330UM30 C25DND330B 3M30-C CR453AC3BAA A77-309044A-2 3100-30U9 8910DPA33V03 90165<br />

40 24 42CF35AJ DP40C4P-F 400-DP40NJ3 ACC430UM10 C25DNF340T 3M40-A CR453AD3HBB A77-309046A-3 3100-30Q10 8910DPA43V14 90170<br />

120 42CF35AF DP40C4P-1 400-DP40ND3 ACC430UM20 C25DNF340A 3M40-B CR453AD3ABB A77-309046A-1 3100-30T10 8910DPA43V02 90171<br />

208/240 42CF35AG DP40C4P-2 400-DP40NA3 ACC430UM30 C25DNF340B 3M40-C CR453AD3BBB A77-309046A-2 3100-30U10 8910DPA43V09 90172<br />

50 24 42DF35AJ — 400-DP50NJ3 ACC530U10 C25FNF350T 3L50-A CR353FE3BH1 A77-288514A-3 3100-30Q16 8910DPA53V14 92459<br />

120 42DF35AF — 400-DP50ND3 ACC530U20 C25FNF350A 3L50-B CR353FE3BA1 A77-288514A-1 3100-30T16 8910DPA53V02 92460<br />

208/240 42DF35AG — 400-DP50NA3 ACC530U30 C25FNF350B 3L50-C CR353FE3BB1 A77-288514A-2 3100-30U16 8910DPA53V09 92461<br />

60 24 42EF35AJ DP60C3P-F 400-DP60NJ3 ACC630U10 C25FNF360T 3L60-A CR353FF3BH1 A77-288517A-3 3100-30Q17 8910DPA63V14 92462<br />

120 42EF35AF DP60C3P-1 400-DP60ND3 ACC630U20 C25FNF360A 3L60-B CR353FF3BA1 A77-288517A-1 3100-30T17 8910DPA63V02 92463<br />

208/240 42EF35AG DP60C3P-2 400-DP60NA3 ACC630U30 C25FNF360B 3L60-C CR353FF3BB1 A77-288517A-2 3100-30U17 8910DPA63V09 92464<br />

75 24 42FE35AJ — 400-DP75NJ3 ACC730U10 C25FNF375T — CR353EG3BH1 A77-288520A-3 3186-30I75 8910DPA73V14 92465<br />

120 42FE35AF — 400-DP75ND3 ACC730U20 C25FNF375A — CR353EG3BA1 A77-288520A-1 3186-30J75 8910DPA73V02 92467<br />

208/240 42FE35AG — 400-DP75NA3 ACC730U30 C25FNF375B — CR353EG3BB1 A77-288520A-2 3186-30K75 8910DPA73V09 92468<br />

90 24 42GE35AJ — — — C25GNF390T — CR353EH3BH1 — 3186-30I90 8910DPA93V14 92469<br />

120 42GE35AF — — ACC930U20 C25GNF390A — CR353EH3BA1 — 3186-30J90 8910DPA93V02 —<br />

208/240 42GE35AG — — ACC930U30 C25GNF390B — CR353EH3BB1 — 3186-30K90 8910DPA93V09 —<br />

This cross reference does not purport to cover all details or variations in<br />

equipment, nor to provide for every possible contingency to be met in<br />

connection with installation, operation, or maintenance. Should further<br />

information be desired or should particular problems arise which are not<br />

covered sufficiently for the purchaser’s purposes, the matter should be<br />

referred to the local Siemens Industry, Inc. sales office.<br />

The contents of this cross reference shall not become part or modify<br />

any prior or existing agreement, commitment or relationship. The<br />

sales contract contains the entire obligation of Siemens Industry, Inc.<br />

The warranty contained in the contract between the parties is the<br />

sole warranty of Siemens Industry, Inc. Any statements contained<br />

herein do not create new warranties or modify the existing warranty.<br />

17-58<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Definite Purpose Control<br />

C<br />

Class 42 & 45<br />

2.38"<br />

B<br />

B<br />

Revised on 10/31/19<br />

Dimensions<br />

E<br />

30-40A 1 Pole C with Shunt<br />

2.38"<br />

2.38"<br />

C<br />

A<br />

B<br />

LABEL<br />

B<br />

Shunt<br />

A<br />

B<br />

LABEL<br />

B<br />

Shunt<br />

D<br />

E<br />

E<br />

D1<br />

LABEL<br />

LABEL<br />

A<br />

Shunt<br />

LABEL<br />

G<br />

A<br />

Shunt<br />

LABEL<br />

G<br />

D<br />

D1<br />

A<br />

Shunt<br />

A<br />

Shunt<br />

D<br />

D1<br />

G<br />

G<br />

G<br />

G<br />

2.38"<br />

30-40A 2 Pole<br />

2.38"<br />

2.38"<br />

C<br />

C<br />

C<br />

A<br />

B<br />

B<br />

B<br />

LABEL<br />

A<br />

B<br />

B<br />

B<br />

LABEL<br />

D<br />

E<br />

E<br />

E<br />

D1<br />

A<br />

A<br />

LABEL<br />

LABEL<br />

G<br />

A<br />

A<br />

LABEL<br />

LABEL<br />

G<br />

D<br />

D<br />

D1<br />

D1<br />

G<br />

G<br />

G<br />

G<br />

30-40A 2 Pole<br />

Optional side mouted<br />

Auxiliary Switch<br />

Optional side mouted<br />

Auxiliary Switch<br />

C<br />

C<br />

C<br />

0.08"<br />

0.08"<br />

0.08"<br />

A<br />

B<br />

Optional side mouted<br />

Auxiliary Switch<br />

Optional side mouted<br />

Auxiliary BSwitch<br />

0.42" 0.42"<br />

0.42" 0.42"<br />

B<br />

0.42" 0.42"<br />

LABEL<br />

A<br />

B<br />

Optional side mouted<br />

Auxiliary Switch<br />

Optional side mouted<br />

Auxiliary BSwitch<br />

0.42" 0.42"<br />

0.42" 0.42"<br />

B<br />

0.42" 0.42"<br />

LABEL<br />

D1<br />

0.30"<br />

0.30"<br />

2.38"<br />

1.50"<br />

2.38"<br />

1.50"<br />

2.38"<br />

1.50"<br />

D<br />

3.64"<br />

17 CONTROL<br />

PRODUCTS<br />

A<br />

A<br />

LABEL<br />

LABEL<br />

A<br />

LABEL<br />

LABEL<br />

A<br />

G<br />

0.62" B 0.62"<br />

B<br />

D1<br />

0.62" 0.62"<br />

E<br />

G<br />

D1<br />

0.30"<br />

D<br />

D<br />

3.64"<br />

3.64"<br />

Optional side mouted<br />

Optional side mouted<br />

Microswitch Blocks G<br />

Microswitch Blocks G<br />

0.62" B 0.62" 0.62" B<br />

0.62"<br />

E<br />

G<br />

G<br />

Optional side mouted<br />

Optional side mouted<br />

0.62" Dimensions B 0.62" 0.62" B<br />

0.62"<br />

Microswitch Blocks<br />

Microswitch BlocksMounting<br />

Max E<br />

Catalog No. FLA Poles A Optional side B mouted C Optional D side mouted D1 Optional E side mouted Screw G Wire Size<br />

45EG10A*A 30 1 3.19 Microswitch 1.97 Blocks 2.46<br />

Auxiliary<br />

1.5<br />

Switch<br />

1.77 Microswitch 1.61Blocks10 8<br />

45GG10A*A C<br />

40 1 3.19 1.97<br />

0.42"<br />

2.46 1.5<br />

B<br />

1.77<br />

0.42"<br />

1.61 10 4<br />

2.87"<br />

45EG20A*A 30 2 3.19 1.97 2.46 Optional 1.5 side mouted 1.77 1.61 10 8<br />

2.24"<br />

0.06"<br />

45GG20A*A 40 2 3.19 1.97 2.46Auxiliary 1.5Switch<br />

1.77 1.61 10 4<br />

42BF35A* 30 3 3.69 2.38 2.87 Optional 3.13 side mouted 3.25 1.98 10 8<br />

C<br />

0.42" B<br />

0.42"<br />

2.87"<br />

42CF35A* 40 3 3.69 2.38 2.87<br />

Auxiliary<br />

3.13<br />

Switch<br />

3.25 1.98 10 4<br />

2.24"<br />

0.30"<br />

0.06"<br />

42BF15A*<br />

C 30-40 2(at 3P)* 3.69 2.38 0.42" 2.87 3.13 B 3.25 0.42" 1.98 10 3.64" 4<br />

2.87"<br />

42CF15A*<br />

LABEL<br />

2.24"<br />

0.06"<br />

Note - 2* Pole is a 3 pole body with center contacts removed.<br />

D1<br />

A<br />

0.30" D<br />

3.19"<br />

3.64"<br />

LABEL<br />

0.30"<br />

Siemens Industry, Inc. 3.64" SPEEDFAX D1 Product Catalog 17-59<br />

A<br />

LABEL<br />

D<br />

3.19"<br />

D1<br />

A<br />

D


A<br />

A<br />

D1<br />

0.30"<br />

D<br />

A<br />

Definite Purpose Control<br />

Class 42 & 45<br />

50-60A 3 Pole<br />

LABEL<br />

G<br />

0.62" B B<br />

Optional side mouted<br />

Microswitch Blocks<br />

0.62" 0.62" 0.62"<br />

E<br />

Optional side mouted<br />

Microswitch Blocks<br />

G<br />

0.62" B B<br />

A<br />

LABEL<br />

G<br />

D1<br />

0.62" 0.62" 0.62"<br />

E<br />

G<br />

Revised on 10/31/19<br />

D<br />

3.64"<br />

Dimensions<br />

Optional side mouted<br />

Microswitch Blocks<br />

Optional side mouted<br />

Optional side mouted Microswitch Blocks<br />

Auxiliary Switch<br />

C<br />

0.06"<br />

0.42" B<br />

0.42"<br />

Optional side mouted<br />

Auxiliary Switch<br />

2.87"<br />

2.24"<br />

C<br />

0.06"<br />

A<br />

0.42" B<br />

0.42"<br />

LABEL<br />

3.64"<br />

D1<br />

3.19"<br />

2.87"<br />

2.24"<br />

0.30"<br />

0.30"<br />

D<br />

A<br />

LABEL<br />

G<br />

0.62" B<br />

0.62"<br />

3.64"<br />

D1<br />

3.19"<br />

1.50"<br />

E<br />

D<br />

75-90A 3 Pole<br />

Optional side mouted<br />

Auxiliary Switch<br />

3.96"<br />

Optional side mouted<br />

Microswitch Blocks<br />

G<br />

0.62" B<br />

0.62"<br />

Optional side mouted<br />

Microswitch Blocks<br />

1.50"<br />

E<br />

3.50"<br />

2.87"<br />

Optional side mouted<br />

Auxiliary Switch<br />

3.96"<br />

5.00"<br />

G 3.50"<br />

2.87"<br />

0.31"<br />

17<br />

A<br />

LABEL<br />

5.00"<br />

D1<br />

G<br />

0.31"<br />

D<br />

CONTROL<br />

PRODUCTS<br />

A<br />

LABEL<br />

B<br />

4.53"<br />

Optional side mouted<br />

Microswitch Blocks<br />

C<br />

D1<br />

2.48"<br />

E<br />

D<br />

B<br />

4.53"<br />

Optional side mouted<br />

Microswitch Blocks<br />

C<br />

2.48"<br />

E<br />

Catalog No. FLA Poles<br />

42DF35A*<br />

42EF35A*<br />

42FE35A*<br />

42GE35A*<br />

Dimensions<br />

A B C D D1 E<br />

Mounting<br />

Screw G<br />

50-60 3 4.04 2.87 3.11 3.13 3.25 2.24 10 2<br />

75-90 3 5.02 3.5 4.39 4.43 4.63 2.87 10 1/10<br />

Max<br />

Wire Size<br />

17-60<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Heavy Duty Control<br />

Catalog Numbering System<br />

General<br />

Class<br />

48 — Overload Size<br />

A — Frame A<br />

B — Frame B<br />

Model<br />

T — ESP200<br />

No. of Poles<br />

3 — 3 Phase<br />

1 — Single Phase<br />

Trip Curve<br />

00 — Class 5, 10, 20 or 30 Selectable<br />

Current Range<br />

A — 0.25–1 a<br />

B — 0.75–3.4 a<br />

C — 3–12 a<br />

D — 5.5–22 a<br />

E — 10–40<br />

F — 13–52<br />

G — 25–100<br />

H — 50–200<br />

Reset<br />

S — Selectable (Man/Auto)<br />

J — 100–300 (3.33-10 current range with 300:5 CT and 1 loop with frame A1 (3-12A)-device)<br />

K — 133–400 (3.33-10 current range with 400:5 CT and 1 loop with frame A1 (3-12A)-device)<br />

L — 200–600 (3.33-10 current range with 600:5 CT and 1 loop with frame A1 (3-12A)-device)<br />

M — 250–750 (3.33-10 current range with 750:5 CT and 1 loop with frame A1 (3-12A)-device)<br />

N — 400–1200 (3.33-10.17 currant range with 1200:5 CT and 1 loop with frame A1 (3-12A)-device)<br />

Class<br />

958 — Overload<br />

Amp Range<br />

E — 10–40<br />

G — 25–100<br />

H — 50–200<br />

Model<br />

B — ESP200<br />

No. of Poles<br />

3 — 3 phase<br />

Trip Curve<br />

A — 958<br />

Type<br />

S — Selectable (Man/Auto)<br />

NEMA & General<br />

Purpose Control<br />

Class<br />

958L<br />

— Overload<br />

Amp Range<br />

Model<br />

B — ESP200<br />

Type<br />

Trip Curve<br />

A — 958L<br />

17 CONTROL<br />

PRODUCTS<br />

D — 5.5–22<br />

E — 10–40<br />

F — 13–52<br />

G — 25–100<br />

H — 50–200<br />

No. of Poles<br />

3 — 3 phase<br />

S — Selectable (Man/Auto)<br />

a Ranges available in Single or 3-phase.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-61


Overload Relays<br />

Solid State ESP200, Class 48, 958 and 958L<br />

General<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Features<br />

b Trip Classes - 5, 10, 20, or 30 Selectable by DIP-switches<br />

b Phase Loss Protection - Trips in less than 3 Seconds<br />

b Phase Unbalance - Trips based on Trip Class selected<br />

b Ground Fault - Trips 60% of Motor Current<br />

b Trip Indicator - Visible<br />

b Ambient Insensitive<br />

b No Heaters Required<br />

b Self-Powered - No outside source required<br />

b FLA dial with wide Adjustment - 4:1 ratio<br />

b Self Protected in short circuit condition (when used with<br />

proper fuses or motor starter protector)<br />

b Test Button - Tests Electronics<br />

b Thermal Memory<br />

b Conformally coated circuit board<br />

b 1 NO and 1NC Contacts Standard. B600, R300<br />

b Operating Temperature: -25 °C - 65 °C<br />

b Repeat Accuracy


Overload Relays<br />

Solid State ESP200, 958, 958L and Bimetal<br />

Revised on 03/31/20<br />

General<br />

ESP200 Solid State Overload<br />

958 or 958L Solid State Overload<br />

Applications<br />

ESP200 Solid State Overloads<br />

Designed for a wide variety of applications.<br />

The field selectable Trip Class 5,<br />

10, 20 or 30 can easily be set by 2 DIP<br />

switches. This eliminates the guess<br />

factor of an application requirements<br />

and provides reduced inventory for<br />

multiple applications. The inherent<br />

benefits of the ESP200 ultimately<br />

results in cost savings for the user.<br />

ESP200 has a 4:1 current adjustment<br />

range with a fine adjustment dial<br />

labeled in full load amps. The heaterless<br />

overload minimizes the heat trapped in<br />

the enclosures, reduces cost for ventilation<br />

or cooling. Easily accessible Reset<br />

button, provides visible and<br />

audible indications to ensure the tripped<br />

overload is ready to re-start.<br />

Designed to replace thermal, or ESP100<br />

overload relays for any application. It<br />

has the same dimensions and footprint<br />

of the ESP100 overload relays. It can<br />

be directly coupled to the contactors<br />

or remotely mounted. In addition to<br />

the NEMA contactor applications, it<br />

also can be used with other types of<br />

controllers for applications requiring DP<br />

or IEC contactors. As a retrofit for other<br />

brands, it is used with a plate available<br />

for retrofitting competitive products.<br />

958 ESP200 Special Use Solid State<br />

Overloads<br />

This overload is specifically designed for<br />

special applications, to provide excellent<br />

protection of hermetically sealed and<br />

artificially cooled motors that require<br />

ambient insensitive and quick trip<br />

response times. Combined with a series<br />

lockout relay, it provides unsurpassed<br />

protection for hermetically sealed<br />

compressor motors in air conditioning<br />

applications. The combination of high trip<br />

speed, current adjustment, and ease of<br />

installation makes it suitable for these<br />

applications. The trip curves are<br />

customized to provide proper overload<br />

protection for these loads without<br />

causing nuisance tripping.<br />

It has selectable manual or automatic<br />

reset mode, and provides ground fault<br />

selection to protect equipment from<br />

damage in case of a fault.<br />

958L ESP200 Oil Field Solid State<br />

Overloads<br />

Specifically designed for the oil market<br />

and the cycling loads experienced with<br />

these types of pumping applications.<br />

These overload relays provide protection<br />

for standard motors, oil well pump<br />

motors, multi-torque connections, and<br />

ultra-high slip motors.<br />

Rotors can be damaged in less than 15<br />

seconds during motor stall conditions<br />

if electrical power is not removed. To<br />

prevent damage during motor stall, the<br />

958L solid state overload removes the<br />

power in 7 seconds at 250% lock rotor<br />

current. Therefore, the motor casing<br />

and the rotor will be protected from<br />

being damage saving the user money<br />

and time.<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-63


Overload Relays<br />

Solid State ESP200 and 3RB20<br />

Revised on 03/31/20<br />

Selection<br />

Ordering Information<br />

For CT’s see Accessories page 17-65.<br />

Dimensions see page 17-133.<br />

To retrofit or direct mount to a contactor, order 49ASMP1, 2, or 3 separately. See<br />

Retrofit Plates below.<br />

For remote mounting of frame size A order 49ASMS1 terminals separately, see page 17-106.<br />

3-Phase, 48ATC3S00<br />

Solid State—Class 48<br />

NEMA & General<br />

Purpose Control<br />

Current Adjustment Range Phase Frame Size Catalog Number MRPD/MLFB List Price $<br />

0.25–1 3 “A” 48ATA3S00 3UB81134AB2<br />

0.75–3.4 3 “A” 48ATB3S00 3UB81134BB2<br />

3–12 3 “A1” 48ATC3S00 3UB81234CW2<br />

5.5–22 3 “A1” 48ATD3S00 3UB81234DW2<br />

10–40 3 “A1” 48ATE3S00 3UB81234EW2<br />

13–52 3 “B” 48BTF3S00 3UB81334FW2<br />

25–100 3 “B” 48BTG3S00 3UB81334GW2<br />

50–200 3 “B” 48BTH3S00 3UB81334HW2<br />

100–300 3 “A1” b 48ATJ3S00 3UB81234JW2<br />

133–400 3 “A1” h 48ATK3S00 3UB81234KW2<br />

200–600 3 “A1” d 48ATL3S00 3UB81234LW2<br />

250–750 3 “A1” g 48ATM3S00 3UB81234MW2<br />

400–1220 3 “A1” e 48ATN3S00 3UB81234NW2<br />

0.25–1 1 “A” 48ATA1S00 3UB88134AB2<br />

0.75–3.4 1 “A” 48ATB1S00 3UB88134BB2<br />

3–12 1 “A1” 48ATC1S00 3UB88234CW2<br />

5.5–22 1 “A1” 48ATD1S00 3UB88234DW2<br />

25-100 1 “B” 48BTG1S00 3UB88334GW2<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Solid State—3RB206 cf , 3-Phase, Manual/Auto Reset<br />

For Contactor Size<br />

Setting Range Amps<br />

Class 10<br />

Catalog Number List Price $<br />

5 55 - 250 3RB2066-1GC2 3RB2066-2GC2<br />

6 160 - 630 3RB2066-1MC2 3RB2066-2MC2<br />

Class 20<br />

Catalog Number List Price $<br />

Retrofit Plates for Contactors, Class 48<br />

Replacement for Starter Sizes ESP200 Overload Frame Size a Retrofit Plate Suffix Plate Kit Separate Price Adder $<br />

Size 00–1 3 ⁄4 A or A1 1P 49ASMP1<br />

Size 2, 2 1 ⁄2 B 2P 49ASMP2<br />

Size 3, 3 1 ⁄2 B 3P 49ASMP3<br />

Size 4 B 4P 49ASMP3<br />

a To determine frame size of replacement solid state<br />

overload, refer to retrofit plates table above.<br />

b Requires use of 300:5 Current Transformers–3 of<br />

97CT005.<br />

c Product Category: IEC.<br />

d Requires use of 600:5 Current Transformers–3 of<br />

97CT008.<br />

e Requires use of 1200:5 Current Transformers–3 of<br />

97CT012.<br />

f Overload has busbar connections.<br />

g Requires use of 750:5 Current Transformers–3 of<br />

97CT009.<br />

h Requires use of 400:5 Current Transformers–3 of<br />

97CT006.<br />

17-64<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Overload Relays<br />

Special Use Solid State Overloads, Class 958 and 958L<br />

Selection<br />

Class 958, 958L<br />

Ordering Information<br />

Dimensions see page 17-133.<br />

Current Transformers<br />

Rating Catalog No. List Price $<br />

150:5 97CT002<br />

200:5 97CT003<br />

250:5 97CT004<br />

300:5 97CT005<br />

400:5 97CT006<br />

600:5 97CT008<br />

750:5 97CT009<br />

1200:5 97CT012<br />

Solid State—Class 958 and 958L<br />

Current Adjustment Range Phase Frame Size Catalog Number MRPD/MLFB List Price $<br />

10–40 3 “A1” 958EB3SA 3UB85235EW2<br />

25–100 3 “B” 958GB3SA 3UB85335GW2<br />

50–200 3 “B” 958HB3SA 3UB85335HW2<br />

5.5–22 3 “A1” 958LDB3SA 3UB85236DW2<br />

10–40 3 “A1” 958LEB3SA 3UB85236EW2<br />

13–52 3 “B” 958LFB3SA 3UB85336FW2<br />

25–100 3 “B” 958LGB3SA 3UB85336GW2<br />

50–200 3 “B” 958LHB3SA 3UB85336HW2<br />

Time - Current - Characteristics<br />

CLASS 48<br />

Time - Current - Characteristics<br />

CLASS 48<br />

Time - Current - Characteristics<br />

CLASS 958, 958L<br />

Time - Current - Characteristics<br />

CLASS 958, 958L<br />

1000<br />

1000<br />

1000<br />

Trip - curve depending on unbalance<br />

Trip - curve depending on unbalance - CLASS 20<br />

CLASS 20<br />

NEMA & General<br />

Purpose Control<br />

Trip time in seconds<br />

500<br />

100<br />

50<br />

CLASS 30 - cold start<br />

Trip time in seconds<br />

500<br />

100<br />

50<br />

Trip time in seconds<br />

500<br />

100<br />

50<br />

phase unbalance = 0%, CLASS 20<br />

phase unbalance = 20%, CLASS 20<br />

phase unbalance = 50%, CLASS 20<br />

phase unbalance = 80%, CLASS 20<br />

phase unbalance = 100%, CLASS 20<br />

17 CONTROL<br />

PRODUCTS<br />

CLASS 20 - cold start<br />

10<br />

10<br />

CLASS 958L<br />

10<br />

CLASS 10 - cold start<br />

5<br />

5<br />

5<br />

CLASS 5 - cold start<br />

CLASS 5 - warm start<br />

CLASS 958<br />

1<br />

0.6 1 1.5 2<br />

5<br />

10<br />

multiple of full load amp (FLA)<br />

multiple of full load amp (FLA)<br />

1<br />

0.6 1 1.5 2<br />

5<br />

10<br />

multiple of full load amp (FLA)<br />

multiple of full load amp (FLA)<br />

1<br />

0.6 1 1.5 2<br />

5<br />

10<br />

multiple of full load amp (FLA)<br />

multiple of full load amp (FLA)<br />

a Temperature rating S25° to R60°C.<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-65


Duplex Heavy Duty Controllers<br />

Revised on 03/31/20<br />

General<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Class 83<br />

Features<br />

Class 84<br />

b Heavy Duty NEMA Starters<br />

b Solid State Overload Relays<br />

b Fusible or MCP<br />

b Heavy Duty Disconnect Handle<br />

b Flexibility with Field Modifications<br />

b Alternator Transfer on De-energization<br />

b UL Listed for Outdoor Use<br />

b UL Listed file #E14900 (class 83); file<br />

#E185287 (class 84)<br />

b CSA certified file #LR 6535 (class 83<br />

& 84)<br />

Application<br />

Duplex pump controls are designed to<br />

perform one or both of two distinct<br />

functions: duplexing and alternation. The<br />

duplexing function provides capacity for<br />

system peaking or above normal demand<br />

without having the full motor capacity<br />

spinning at all times. It also provides<br />

standby capacity for use when one of the<br />

motors or pumps is disabled. The duplexing<br />

function is also referred to as lead/lag<br />

or main/standby. When two pumps or<br />

compressors are controlled by a duplex<br />

controller, they are started in sequence<br />

as necessary to attain preset values of<br />

pressure, flow or liquid level.<br />

Two field devices such as pressure<br />

switches or float switches provide<br />

electrical signals to the duplex controller.<br />

One remote device is set to initiate the<br />

starting of the lead motor. This motor is<br />

rated to handle normal system demand.<br />

The second motor is usually the same<br />

rating and is referred to as the lag motor.<br />

It is only energized when the system<br />

demand is greater than the capacity of<br />

the lead motor. The lag motor is started<br />

when the second remote device is<br />

signalling for more output than the<br />

lead motor can produce.<br />

The alternation function reverses the<br />

lead and lag mode for the two motors in<br />

a duplex system. Upon alternation the<br />

first motor as described above becomes<br />

the lag motor and the second motor<br />

assumes the lead function. The<br />

alternation is usually programmed to<br />

occur at any time both pumps come to<br />

rest. The alternation function equalizes<br />

wear on the two machines and extends<br />

the life of seals and bearings.<br />

Enclosure Types<br />

Duplex controllers are available in<br />

NEMA 1, 12/3/3R, 4 (painted) and<br />

4/4X (stainless) enclosures.<br />

Enclosures protect personnel from<br />

contact with live parts and depending<br />

upon the construction, protect the<br />

control in varying degrees from physical<br />

damage and harmful atmospheres. All<br />

enclosures are supplied with corrosion<br />

resistant finishes.<br />

Heavy Duty Starters<br />

These Duplex controllers use the same<br />

starters described in the heavy duty<br />

starter section of this catalog.<br />

Siemens Type ETI Circuit Breaker<br />

The ETI circuit breaker is a device<br />

designed specifically for application<br />

in motor circuits. The ETI is a magnetic<br />

only protective device designed to<br />

provide protection against short<br />

circuit current.<br />

The instantaneous-only type ETI circuit<br />

breaker employs adjustable magnetic<br />

trip settings to allow broader application<br />

ranges and a higher degree of motor<br />

short circuit protection.<br />

Features<br />

Two control transformers may be<br />

provided for low voltage control to<br />

safeguard personnel from high voltage.<br />

One transformer is required for each<br />

starter to provide independent control<br />

circuits.<br />

A Hand-Off-Auto selector switch for each<br />

starter may be mounted in the enclosure<br />

door or furnished separately for remote<br />

control. Test push buttons or pilot lights<br />

may also be installed on the enclosure.<br />

Solid-state Overload Relays are supplied<br />

as standard.<br />

Heavy Duty Disconnect Switches<br />

The disconnect switch that goes the<br />

distance in durability, performance and<br />

reliability has the following advantages:<br />

b Visible blades for the highest level<br />

of safety<br />

b Double break switching action to<br />

reduce arcing, increase lifetime and<br />

eliminate the “electric hinge”<br />

b More rugged positive action switch<br />

b Oversized lugs are standard<br />

b Line side shield to help guard<br />

personnel from contact with live parts<br />

b Higher horsepower rating for<br />

design E high efficiency motors<br />

b UL listed for IIsco, Burndy and T&B<br />

crimp type lugs<br />

b The 200A switch accepts up to 300<br />

MCM versus 250 MCM wire size<br />

Its rugged construction - with a high<br />

fault withstand rating of 100kA at 600<br />

VAC when fused with class R rated<br />

fuses - meets the most stringent<br />

industry standards set forth by the<br />

automotive, petro-chemical, and pulp<br />

and paper industries. UL recognized and<br />

CSA certified, our disconnect switches<br />

are available either non-fusible or fusible<br />

with class R and class J fuse clips.<br />

17-66<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Duplex Heavy Duty Controllers<br />

Non-Combination, Class 83<br />

Revised on 03/31/20<br />

Selection<br />

Ordering Information<br />

Standard duplex controllers include an alternator indicated<br />

by characters "92" within the catalog number. The standard<br />

coil voltage supplied with the alternator is 120V separate<br />

control. This is the only control voltage available with the<br />

alternator.<br />

To omit the alternator, change the character string within<br />

the catalog number from "92" to "95". All coil voltages listed<br />

in the coil table are valid with non-alternator controllers.<br />

To change the coil voltage for non-alternator controllers,<br />

change the 9th character in the catalog number with a<br />

letter shown in the coil table.<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-151.<br />

Wiring Diagrams see page 17-167.<br />

Replacement Parts see page 17-120.<br />

Coil Table<br />

60Hz Voltage Letter<br />

24 J<br />

120 F<br />

200–208 D<br />

220–240 G<br />

277 L<br />

440–480 H<br />

550–600 E<br />

Non-Combination (with Solid-State Overload)<br />

Max Hp<br />

200<br />

Volts<br />

230<br />

Volts<br />

460<br />

Volts<br />

575<br />

Volts<br />

NEMA<br />

Size<br />

Half<br />

Size<br />

Overload<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

Enclosure<br />

NEMA 1<br />

General Purpose<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

304 Stainless Steel<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

NEMA 4 Painted<br />

Watertight, Dust-tight<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

NEMA 12<br />

NEMA 3/3R<br />

Industrial Use<br />

Weatherproof<br />

Catalog<br />

Number<br />

1<br />

⁄6<br />

1<br />

⁄6<br />

1<br />

⁄3<br />

1<br />

⁄2 0 — 0.25–1 A 83CUA92BF 83CUA92WF 83CUA92EF 83CUA920F<br />

1<br />

⁄2<br />

3<br />

⁄4 1 1 ⁄2 2 0 — 0.75–3.4 A 83CUB92BF 83CUB92WF 83CUB92EF 83CUB920F<br />

2 2 5 5 0 — 3–12 A1 83CUC92BF 83CUC92WF 83CUC92EF 83CUC920F<br />

3 3 — — 0 — 5.5–22 A1 83CUD92BF 83CUD92WF 83CUD92EF 83CUD920F<br />

1<br />

⁄6<br />

1<br />

⁄6<br />

1<br />

⁄3<br />

1<br />

⁄2 1 — 0.25–1 A 83DUA92BF 83DUA92WF 83DUA92EF 83DUA920F<br />

List<br />

Price $<br />

NEMA & General<br />

Purpose Control<br />

1<br />

⁄2<br />

3<br />

⁄4 1 1 ⁄2 2 1 — 0.75–3.4 A 83DUB92BF 83DUB92WF 83DUB92EF 83DUB920F<br />

2 2 5 5 1 — 3–12 A1 83DUC92BF 83DUC92WF 83DUC92EF 83DUC920F<br />

3 3 10 10 1 — 5.5–22 A1 83DUD92BF 83DUD92WF 83DUD92EF 83DUD920F<br />

7 1 ⁄2 7 1 ⁄2 — — 1 — 10–40 A1 83DUE92BF 83DUE92WF 83DUE92EF 83DUE920F<br />

10 10 15 15 — 1 3 ⁄4 10–40 A1 83EUE92BF 83EUE92WF 83EUE92EF 83EUE920F<br />

10 15 25 25 2 — 13–52 B 83FUF92BF 83FUF92WF 83FUF92EF 83FUF920F<br />

15 20 30 30 — 2 1 ⁄2 25–100 B 83GUG92BF 83GUG92WF 83GUG92EF 83GUG920F<br />

25 30 50 50 3 — 25–100 B 83HUG92BF 83HUG92WF 83HUG92EF 83HUG920F<br />

30 40 75 75 — 3 1 ⁄2 50–200 B 83IUH92BF 83IUH92WF 83IUH92EF 83IUH920F<br />

40 50 100 100 4 — 50–200 B 83JUH92BF 83JUH92WF 83JUH92EF 83JUH920F<br />

17 CONTROL<br />

PRODUCTS<br />

Note: Hp’s shown above are based on the overload<br />

amp range for the FLA’s (per the National Electric<br />

Code) of typical industrial motors. All starter sizes<br />

carry one maximum Hp rating.<br />

Not available on standard alternator style (‘92’ in the<br />

catalog number).<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-67


Duplex Heavy Duty Controllers<br />

Combination Disconnect (Fusible & Non-Fusible), Class 84<br />

Revised on 03/31/20<br />

Selection<br />

Ordering Information<br />

Standard duplex controllers include an alternator indicated<br />

by characters "92" within the catalog number. The standard<br />

coil voltage supplied with the alternator is 120V separate<br />

control. This is the only control voltage available with the<br />

alternator.<br />

To omit the alternator, change the character string within<br />

the catalog number from "92" to "95". All coil voltages listed<br />

in the coil table are valid with non-alternator controllers.<br />

To change the coil voltage for non-alternator controllers,<br />

change the 10th character in the catalog number with a<br />

letter shown in the coil table.<br />

For factory installed fusible disconnect, see page 17-115.<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-151.<br />

Wiring Diagrams see page 17-167.<br />

Replacement Parts see page 17-120.<br />

Coil Table<br />

60Hz Voltage Letter<br />

24 J<br />

120 F<br />

200–208 D<br />

220–240 G<br />

277 L<br />

440–480 H<br />

550–600 E<br />

Two Disconnect Switches with Solid-State Overload<br />

NEMA & General<br />

Purpose Control<br />

Max Hp<br />

200<br />

Volts<br />

1<br />

⁄6<br />

1<br />

⁄2<br />

230<br />

Volts<br />

460<br />

Volts<br />

575<br />

Volts<br />

NEMA<br />

Size<br />

Half<br />

Size<br />

Overload<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

Disc.<br />

Amp<br />

Range<br />

Enclosure<br />

NEMA 1<br />

General Purpose<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

304 Stainless Steel<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

NEMA 4 Painted<br />

Watertight, Dust-tight<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

NEMA 12<br />

NEMA 3/3R<br />

Industrial Use<br />

Weatherproof<br />

Catalog<br />

Number<br />

1<br />

⁄6<br />

1<br />

⁄3<br />

1<br />

⁄2 0 — 0.25–1 A 30 84CUA92BDF 84CUA92WDF 84CUA92EDF 84CUA920DF<br />

3<br />

⁄4 1 1 ⁄2 2 0 — 0.75–3.4 A 30 84CUB92BDF 84CUB92WDF 84CUB92EDF 84CUB920DF<br />

List<br />

Price $<br />

2 2 5 5 0 — 3–12 A1 30 84CUC92BDF 84CUC92WDF 84CUC92EDF 84CUC920DF<br />

3 3 — — 0 — 5.5–22 A1 30 84CUD92BDF 84CUD92WDF 84CUD92EDF 84CUD920DF<br />

1 1 1<br />

⁄6 ⁄6 ⁄3<br />

1<br />

⁄2 1 — 0.25–1 A 30 84DUA92BDF 84DUA92WDF 84DUA92EDF 84DUA920DF<br />

17<br />

CONTROL<br />

PRODUCTS<br />

1<br />

⁄2<br />

3<br />

⁄4 1 1 ⁄2 2 1 — 0.75–3.4 A 30 84DUB92BDF 84DUB92WDF 84DUB92EDF 84DUB920DF<br />

2 2 5 5 1 — 3–12 A1 30 84DUC92BDF 84DUC92WDF 84DUC92EDF 84DUC920DF<br />

3 3 10 10 1 — 5.5–22 A1 30 84DUD92BDF 84DUD92WDF 84DUD92EDF 84DUD920DF<br />

7 1 ⁄2 7 1 ⁄2 — — 1 — 10–40 A1 30 84DUE92BDF 84DUE92WDF 84DUE92EDF 84DUE920DF<br />

10 10 15 15 — 1 3 ⁄4 10–40 A1 60 84EUE92BDF 84EUE92WDF 84EUE92EDF 84EUE920DF<br />

10 15 25 25 2 — 13–52 B 60 84FUF92BDF 84FUF92WDF 84FUF92EDF 84FUF920DF<br />

15 20 30 30 — 2 1 ⁄2 25–100 B 100 84GUG92BDF 84GUG92WDF 84GUG92EDF 84GUG920DF<br />

20 25 50 50 3 — 25–100 B 100 84HUG92BDF 84HUG92WDF 84HUG92EDF 84HUG920DF<br />

30 40 75 75 — 3 1 ⁄2 50–200 B 200 84IUH92BDF 84IUH92WDF 84IUH92EDF 84IUH920DF<br />

40 50 100 100 4 — 50–200 B 200 84JUH92BDF 84JUH92WDF 84JUH92EDF 84JUH920DF<br />

Note: Hp’s shown above are based on the overload<br />

amp range for the FLA’s (per the National Electric<br />

Code) of typical industrial motors. All starter sizes<br />

carry one maximum Hp rating.<br />

Not available on standard alternator style<br />

(‘92’ in the catalog number).<br />

17-68<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Duplex Heavy Duty Controllers<br />

Combination Circuit Breaker, Class 84<br />

Revised on 03/31/20<br />

Selection<br />

Ordering Information<br />

Standard duplex controllers include an alternator indicated<br />

by characters "92" within the catalog number. The standard<br />

coil voltage supplied with the alternator is 120V separate<br />

control. This is the only control voltage available with the<br />

alternator.<br />

To omit the alternator, change the character string within<br />

the catalog number from "92" to "95". All coil voltages listed<br />

in the coil table are valid with non-alternator controllers.<br />

To change the coil voltage for non-alternator controllers,<br />

change the 10th character in the catalog number with a<br />

letter shown in the coil table.<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-151.<br />

Wiring Diagrams see page 17-167.<br />

Replacement Parts see page 17-120.<br />

Coil Table<br />

60Hz Voltage Letter<br />

24 J<br />

120 F<br />

200–208 D<br />

220–240 G<br />

277 L<br />

440–480 H<br />

550–600 E<br />

2 Motor Circuit Protectors (with Solid-State Overload)<br />

Max Hp<br />

Overload<br />

Motor<br />

Circuit<br />

Interrupter<br />

ETI<br />

Enclosure<br />

NEMA 1<br />

General Purpose<br />

NEMA 4/4X Stainless<br />

Watertight, Dust-tight, Corrosion<br />

Resistant , 304 Stainless Steel,<br />

NEMA 4 Painted<br />

Watertight, Dust-tight<br />

NEMA 12<br />

NEMA 3/3R<br />

Industrial Use, Weatherproof<br />

200<br />

Volts<br />

230<br />

Volts<br />

460<br />

Volts<br />

575<br />

Volts<br />

NEMA<br />

Size<br />

Half<br />

Size<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

1<br />

⁄6<br />

1<br />

⁄6<br />

1<br />

⁄3<br />

1<br />

⁄2 0 — 0.25–1 A 3 84CUA92BMF 84CUA92WMF 84CUA92EMF 84CUA920MF<br />

1<br />

⁄2<br />

3<br />

⁄4 1 1 ⁄2 2 0 — 0.75–3.4 A 3 84CUB92BMF 84CUB92WMF 84CUB92EMF 84CUB920MF<br />

2 2 5 5 0 — 3–12 A1 10 84CUC92BMF 84CUC92WMF 84CUC92EMF 84CUC920MF<br />

3 3 — — 0 — 5.5–22 A1 25 84CUD92BMF 84CUD92WMF 84CUD92EMF 84CUD920MF<br />

1<br />

⁄6<br />

1<br />

⁄6<br />

1<br />

⁄3<br />

1<br />

⁄2 1 — 0.25–1 A 3 84DUA92BMF 84DUA92WMF 84DUA92EMF 84DUA920MF<br />

1<br />

⁄2<br />

3<br />

⁄4 1 1 ⁄2 2 1 — 0.75–3.4 A 3 84DUB92BMF 84DUB92WMF 84DUB92EMF 84DUB920MF<br />

2 2 5 5 1 — 3–12 A1 10 84DUC92BMF 84DUC92WMF 84DUC92EMF 84DUC920MF<br />

3 3 10 10 1 — 5.5–22 A1 25 84DUD92BMF 84DUD92WMF 84DUD92EMF 84DUD920MF<br />

7 1 ⁄2 7 1 ⁄2 — — 1 — 10–40 A1 30 84DUE92BMF 84DUE92WMF 84DUE92EMF 84DUE920MF<br />

— — 15 15 — 1 3 ⁄4 10–40 A1 40 84EUE92BMF 84EUE92WMF 84EUE92EMF 84EUE920MF<br />

10 15 25 25 2 — 13–52 B 50 84FUF92BMF 84FUF92WMF 84FUF92EMF 84FUF920MF<br />

15 20 30 30 — 2 1 ⁄2 25–100 B 100 84GUG92BMF 84GUG92WMF 84GUG92EMF 84GUG920MF<br />

20 25 50 50 3 — 25–100 B 100 84HUG92BMF 84HUG92WMF 84HUG92EMF 84HUG920MF<br />

30 40 75 75 — 3 1 ⁄2 50–200 B 125 84IUH92BMF 84IUH92WMF 84IUH92EMF 84IUH920MF<br />

40 50 100 100 4 — 50–200 B 150 84JUH92BMF 84JUH92WMF 84JUH92EMF 84JUH920MF<br />

List<br />

Price $<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Note: Hp’s shown above are based on the overload<br />

amp range for the FLA’s (per the National Electric<br />

Code) of typical industrial motors. All starter sizes<br />

carry one maximum Hp rating.<br />

Product Category: NEMA<br />

Not available on standard alternator style<br />

(‘92’ in the catalog number).<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-69


Pump Control Panels<br />

Slim Line NEMA Pump Controller for the Agricultural industry, Class 82<br />

General<br />

Features<br />

The Class 82 Slim Line NEMA Pump was designed<br />

specifically for the agricultural market. It is well suited for<br />

irrigation and similar pumping applications and is built to<br />

withstand the harsh elements of the outdoors<br />

Typical applications include:<br />

• Crop irrigation<br />

• Sprinklers, misters and soakers<br />

• Watering for livestock and other dairy applications<br />

• Ground dewatering for excavation and construction sites<br />

NEMA & General<br />

Purpose Control<br />

Why you should use the Class 82 Pump Panel<br />

• Simplicity and its compact lightweight design makes<br />

this an attractive solution to your budgeting challenges.<br />

• The contactor is NEMA rated to provide reliable motor<br />

control and protection expected in the most demanding<br />

applications.<br />

• The ESP200 solid-state overload relay has a protective<br />

coating on the circuit board which gives it superior protection<br />

against high humidity, condensation and corrosive<br />

environments.<br />

• Its size and weight is about half that of the Class 87<br />

which increases the ease of installation.<br />

Catalog Numbering System<br />

82 A D C 6 F B H<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Series<br />

A = Standard size enclosure<br />

B = Extra large enclosure (starter size 1 only)<br />

Starter Size<br />

D = 1<br />

F = 2<br />

OLR Current Range<br />

B = 0.75-3.4A<br />

C = 3-12A<br />

D = 5.5-22A<br />

E = 10-40A<br />

F = 13-52A<br />

Cover Control<br />

6 = HOA selector switch with Start push button<br />

Disconnect Type<br />

F = Fusible disconnect<br />

Disconnect & Fuse Clip Rating<br />

A = 30A/250V<br />

B = 30A/600V<br />

C = 60A/250V<br />

D = 60A/600V<br />

Coil Voltage<br />

F = 110VAC 50HZ / 120VAC 60HZ<br />

G = 220VAC 50HZ / 240VAC 60HZ<br />

H = 480VAC 60HZ<br />

17-70<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Pump Control Panels<br />

Slim Line NEMA Pump Controller for the Agricultural industry, Class 82<br />

Revised on 04/20/17<br />

General<br />

Ordering Information<br />

Field Modification Kits<br />

(see accessories on this page)<br />

Factory Modifications (NA)<br />

Dimensions see page 17-150<br />

Wiring Diagram see page 17-169<br />

Replacement Parts<br />

(refer to instruction sheet A5E35327591A)<br />

Coil Table<br />

50/60Hz Voltage<br />

110VAC 50HZ /<br />

120VAC 60HZ<br />

220VAC 50HZ /<br />

240VAC 60HZ<br />

480VAC 60HZ<br />

Letter<br />

F<br />

G a<br />

H b<br />

Product Selection<br />

Max Hp Rating<br />

Overload<br />

HOA & Start Push Button<br />

Motor Voltage<br />

Relay Amp Disc. Amp Fuse Clip HOA & Start Push Button (Extra wide Encl)<br />

230 460 NEMA Size Range<br />

Rating Amp/Volts Catalog Number List Price $ Catalog Number List Price $<br />

— 1 1 0.75–3.4 30 30A/600V 82ADB6FB* 82BDB6FB* c<br />

— 5 1 3–12 30 30A/600V 82ADC6FB* 82BDC6FB* c<br />

— 10 1 5.5–22 30 30A/600V 82ADD6FB* 82BDD6FB* c<br />

— 10 1 10–40 30 30A/600V — 82BDE6FB* c<br />

2 — 1 3–12 30 30A/250V 82ADC6FA* 82BDC6FA* c<br />

3 — 1 5.5–22 30 30A/250V 82ADD6FA* 82BDD6FA* c<br />

7 1/2 — 1 10–40 30 30A/250V 82ADE6FA* 82BDE6FA* c<br />

— 25 2 13-52 60 60A/600V 82AFF6FD* c —<br />

15 — 2 13-52 60 60A/250V 82AFF6FC* c —<br />

Replace the (*) with a letter from the coil table.<br />

c Available in May <strong>2017</strong>.<br />

NEMA & General<br />

Purpose Control<br />

Accessories<br />

Image<br />

Description<br />

Catalog<br />

Number<br />

List<br />

Price<br />

Image<br />

Description<br />

Catalog<br />

Number<br />

List<br />

Price<br />

3/4" type 3R conduit hub ECHS075<br />

1" type 3R conduit hub ECHS100<br />

1 1/4" type 3R conduit hub ECHS125<br />

1 1/2" type 3R conduit hub ECHS150<br />

Contactor auxiliary<br />

contacts, side mounted<br />

1 NO/NC (NEMA A300/<br />

Q300)<br />

3RH29111DA11<br />

17 CONTROL<br />

PRODUCTS<br />

Disconnect switch<br />

auxiliary contacts<br />

2 NO/2 NC DPDT<br />

(NEMA A600)<br />

HA261234<br />

ESP200 tamper resistance<br />

cover<br />

49ASTC1<br />

Fuse puller kit<br />

for 30A switch (1 kit<br />

required per switch)<br />

HP61<br />

30A, 240V Class R<br />

Fuse Clip Kits<br />

HR21<br />

30A, 600V Class R<br />

Fuse Clip Kits<br />

HR612<br />

a G coil is not available with a 600v disconnect<br />

b H coil is not available with a 250v disconnect<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-71


Pump Control Panels<br />

Slim Line NEMA Pump Controller for the Agricultural industry, Class 82<br />

Selection<br />

Class 82 Technical information<br />

General Technical Data:<br />

Weight<br />

Height x Width x Depth<br />

Maximum altitude<br />

Ambient (outside enclosure) storage temperature<br />

Ambient (outside enclosure) operating temperature<br />

Country of origin<br />

Size 1 (Standard Encl.) 23lbs.<br />

Size 1 (Extra Wide Encl.) 47lbs.<br />

Size 2 (Standard Encl.) 47lbs.<br />

Size 1 (Standard Encl.) 26 x 12 x 5in.<br />

Size 1 (Extra Wide Encl.) 35 x 17 x 6in.<br />

Size 2 (Standard Encl.) 35 x 17 x 6in.<br />

6560 ft.<br />

(-30 to 65)°C / (-22 to 149)°F<br />

(-20 to 40)°C / (-4 to 104)°F<br />

Mexico<br />

Horsepower Rating:<br />

See selection table above<br />

See selection table above<br />

Contactor:<br />

Number of NO main contacts 3<br />

Amp rating<br />

32A, 50A<br />

Mechanical operating cycles 10,000,000<br />

NEMA & General<br />

Purpose Control<br />

17<br />

Internal / Standard Auxiliary Contact:<br />

Number of NC / NO auxiliary contacts<br />

NEMA contact rating designation<br />

Optional auxiliary contacts available<br />

Coil:<br />

Voltage<br />

Apparent pull-in / holding power<br />

Normal coil operating limits (% of rated voltage)<br />

Pick-up time / Drop-out time<br />

1NC / 1NO<br />

A600 AC / Q600 DC<br />

Yes<br />

220/230V 50/60Hz, 460V 60Hz, or 110/120V 50/60Hz<br />

81 VA / 10.5 VA<br />

80% - 110% at 60Hz<br />

8-40 / 4-16 msec<br />

CONTROL<br />

PRODUCTS<br />

Overload Relay:<br />

Current range<br />

0.75 - 3.4 or 3 - 12 or 5.5 - 22 or 10 - 40 Amps or 13 - 52 Amps<br />

Trip Class Class 5 / 10 (factory set) / 20 / 30<br />

Trip detection<br />

Overload, phase failure, phase unbalance, ground fault<br />

Phase failure sensitivity<br />

Trip time after phase loss: < 3 sec<br />

Repeat accuracy Within 1%<br />

Reset options<br />

Manual, automatic and remote<br />

External reset<br />

Yes<br />

Test function<br />

Electronics and manual actuation<br />

Conformal coating on printed circuit board<br />

Yes<br />

Number of NC / NO auxiliary contacts<br />

1NC /1NO<br />

Rating of auxiliary contacts<br />

B600 AC / R300 DC<br />

Single contact isolation<br />

600 V<br />

Dual contact isolation<br />

300 V differing polarity / 600 V common polarity<br />

17-72<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Pump Control Panels<br />

Slim Line NEMA Pump Controller for the Agricultural industry, Class 82<br />

Revised on 03/17/17<br />

Technical Data<br />

Class 82 Technical information<br />

Disconnect Switch:<br />

Rating<br />

Fuse type accepted<br />

Enclosure:<br />

Type<br />

Rating<br />

30 A with 30A/600 or 30A/250 V Class H fuse clips<br />

60 A with 60A/600 or 60A/250 V Class H fuse clips<br />

Class H, J or R<br />

NEMA Type 3/3R enclosure<br />

Weather proof for outdoor use<br />

Standard Control Devices:<br />

Hand-Off-Auto selector switch<br />

Start push button<br />

3SU1 30mm, round, metal with matte finish<br />

3SU1 30mm, round, metal with matte finish<br />

Mounting / Wiring:<br />

Mounting orientation<br />

Vertical<br />

Mounting type<br />

Pole and surface<br />

Disconnect line side connection type / torque<br />

Box lug / 35 lb in (14 - 10); 40 lb in (8); 45 lb in (6 - 4) AWG<br />

Disconnect line side solid and stranded conductors 1x(14 - 2 AWG) 60/75°C AL or CU<br />

Power terminal block connection type / torque<br />

Screw / 24 - 32 lb - in<br />

Power terminal block solid and stranded conductors 1x(18 - 2 AWG) 75°C CU<br />

Control terminal block connection type / torque<br />

Screw / 12 - 18 lb - in<br />

Control terminal block solid and stranded conductors 1x(22 - 8 AWG) 75°C CU<br />

Coil connection type / torque<br />

Screw / 7 - 10 lb in<br />

Coil solid and standed conductors<br />

2x(16 - 12 AWG) CU 60/75°C<br />

Main auxiliary contact connection type / torque<br />

Screw / 7 - 10 lb in<br />

Main auxiliary contact solid and stranded conductors 2x(20 - 16), 2x(18 - 14) 75°C CU<br />

OLR auxiliary contact connection type / torque<br />

Screw / 7 - 10 lb in<br />

OLR auxiliary contact solid and starnded conductors 2x(20 - 14 AWG) CU 60/75°C<br />

Short Circuit Current Rating:<br />

Fuses 10kA@600V (Class H or K); 85kA@600V (Class R or J)<br />

Certificates / Approvals:<br />

cULus UL (file no. E185287)<br />

UL rated Service Entrance Equipment<br />

ISO 9001 certification<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-73


Pump Control Panels<br />

Class 87, 88<br />

Revised on 03/31/20<br />

General<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Features<br />

b Fully Gasketed NEMA 3R Rainproof<br />

Enclosures<br />

b 100,000 Amp Interrupting Capacity<br />

with Class R Fuses<br />

b Heavy Duty NEMA Starters<br />

b Solid State Overload Relays<br />

b Heavy Duty Disconnect Handle<br />

b Available in Reduced Voltage Versions<br />

b Bold Pilot Legend on Front<br />

b Generous Accessory Space<br />

b Copper Grounding Lug For Three<br />

#6 Wires<br />

b UL Listed for Outdoor Use and<br />

Service Equipment File #E185287<br />

Application<br />

Heavy duty pump control panels are<br />

designed to withstand the most<br />

demanding environments. Typical<br />

applications include irrigation, agriculture,<br />

petrochemical, wastewater treatment<br />

and wherever motor control is<br />

challenged by harsh elements.<br />

Installation is easy. Panels are factory<br />

wired to provide flexible control and<br />

protect against short circuits and<br />

overloads. Ample space is provided<br />

for field modifications and installation<br />

of accessories.<br />

The pump control panels feature a full<br />

sized removable auxiliary panel for the<br />

mounting of accessories. The fusible<br />

version features fuse clips for full sized<br />

RK5 or compact class J fuses and<br />

accessory mounting space for the<br />

most commonly used accessories.<br />

Class 87 pump panels become jockey<br />

pump panels with the addition of a<br />

pressure switch. The jockey pump’s<br />

primary function is to maintain water<br />

pressure at a preset level and thus<br />

compensate for possible shortage of<br />

water in the pumping system. When the<br />

water pressure drops below the preset<br />

level, the pressure switch energizes<br />

the starter which in turn activates the<br />

jockey pump. The water pressure is then<br />

brought back up to the desired level. This<br />

insures the maintenance of proper water<br />

pressure at all times.<br />

Features<br />

Specified by Fortune 500 companies,<br />

Siemens NEMA starters offer<br />

prolonged service under severe duty<br />

conditions. NEMA rated, these starters<br />

utilize large silver cadmium oxide<br />

contacts and wide copper heat sinks<br />

to ensure rapid heat dissipation and<br />

maximum electrical life.<br />

ESP200 solid state overload relay<br />

Refer to the section on Class 48 overload<br />

relays for features and benefits.<br />

Pump panels are factory set at trip<br />

Class 10.<br />

HOA and Start Pushbutton<br />

Every pump panel comes with an HOA<br />

and a start pushbutton.<br />

Half Size Starters<br />

Siemens motor matched starters feature<br />

all the rugged performance characteristics<br />

of our NEMA rated starter sizes, but are<br />

fractionally sized to more closely match<br />

your exact motor rating. As a result,<br />

significant economic savings are made<br />

possible without sacrificing the reliability<br />

you expect from a heavy duty starter.<br />

These additional starter sizes have the<br />

reserve capacity to handle occasional<br />

plugging and jogging without de-rating<br />

the device.<br />

Siemens motor matched can save hundreds,<br />

even thousands of dollars per<br />

project.<br />

Siemens motor matched starters comply<br />

with NEMA, UL and CSA standards.<br />

17-74<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Pump Control Panels<br />

Class 87, 88<br />

Revised on 03/31/20<br />

General<br />

Panels are predrilled for easy repositioning<br />

of the fuse trailer block to accommodate<br />

250 and 600 volt fuses and full sized RK<br />

or compact J fuses. Circuit breakers are<br />

also available.<br />

Heavy Duty Fusible<br />

Disconnect Switch<br />

The disconnect switch has the following<br />

advantages:<br />

b Visible blades for the highest<br />

level of safety<br />

b Double Break Switching Action<br />

to reduce arcing, increase lifetime<br />

and eliminate the “electric hinge”<br />

b Oversized lugs are standard<br />

b Line side shield to help guard<br />

personnel from contact with live parts<br />

Motor Circuit Protector<br />

The motor circuit protector provides fast,<br />

accurate fault clearing that will minimize<br />

damage to the motor and control<br />

apparatus and protect branch circuit<br />

conductors. Continuous current ratings<br />

and adjustable trip ranges meet NEC<br />

requirements for full load and locked<br />

rotor currents. The adjustable<br />

instantaneous trip point can be set<br />

precisely to assure fault protection<br />

and eliminate nuisance tripping.<br />

Removable Door<br />

Enclosure door may be lifted off to make<br />

wiring easier.<br />

Mounting Flanges<br />

Convenient flanges at top and bottom<br />

of the enclosure provide easy mounting.<br />

They fit pole or flat surfaces using<br />

keyhole slots.<br />

Quarter Turn Latches<br />

Quarter turns are utilized to secure the<br />

door.<br />

Wind Catches<br />

A wind catch is provided to prevent the<br />

door from slamming shut (or open) due<br />

to high wind conditions.<br />

Safety Disconnect Handle<br />

Up to three padlocks can be used to<br />

lock the disconnect in the OFF position.<br />

Maintenance work can be performed<br />

without hazard to personnel.<br />

External Reset<br />

The overload relay may be quickly reset<br />

by means of a button on the front of the<br />

enclosure.<br />

Ground Lugs<br />

Insures proper connecting of ground<br />

wires and lightning arresters.<br />

UL Listed<br />

Assures proper construction throughout<br />

control panel.<br />

Reduced Voltage<br />

Available in part winding, wye delta and<br />

auto transformer types, these controls<br />

may be necessary where the power<br />

company limits the amount of current<br />

drawn from its lines, or where starting<br />

torque must be reduced.<br />

Fully gasketed NEMA 3/12 weatherproof<br />

enclosures are supplied with<br />

Class 88 reduced voltage starters.<br />

Part Winding Starters apply starting<br />

current in timed steps to minimize<br />

voltage fluctuations.<br />

Auto Transformer Starters maintain<br />

a closed circuit during transition and<br />

eliminate voltage or current surges.<br />

They draw less current than part winding<br />

starters and are well suited for starting<br />

motors over 20 Hp.<br />

Wye Delta starters and motors are<br />

used in areas where the power supply is<br />

inadequate to supply full starting current<br />

without objectionable voltage drop or for<br />

applications where low starting torque is<br />

required. Centrifugal pumps and similar<br />

apparatus requiring a low starting torque<br />

are typical applications. Both ends of all<br />

three windings of the wye delta motor<br />

are brought out so that they may be<br />

accessible for reconnecting from wye<br />

to delta.<br />

Auxiliary Equipment<br />

Pilot Lights are easily installed on the<br />

enclosure. Oil Tight and Heavy Duty,<br />

they meet NEMA A600 requirements.<br />

Lightning Arresters protect the control<br />

panel from lightning induced surges.<br />

Undervoltage and Phase Sensing<br />

Relays protect the pump against low<br />

voltage, voltage imbalance, loss of phase<br />

and phase reversal.<br />

Anti-Backspin Timers prevent the<br />

motor from starting during motor/shaft<br />

backspin.<br />

Class 87 NEMA Vacuum Starter<br />

Pump Control Panels<br />

The Siemens vacuum starter pump<br />

controllers are designed for the harshest<br />

environments. Typical environments<br />

include chemical, petrochemical,<br />

waste water treatment and mining.<br />

Contaminations present in these<br />

severe environments are detrimental<br />

to conventional air-break contacts<br />

decreasing their life expectancy and<br />

reliability. The Siemens vacuum starter<br />

pump controllers are well suited for<br />

these environments because the<br />

contacts are contained in hermetically<br />

sealed contact tubes. This prevents<br />

contaminates in the atmosphere from<br />

affecting the operation of the contacts.<br />

Additionally, neither arcs nor arcing<br />

gases are produced which dramatically<br />

increases the electrical endurance of<br />

the contacts.<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-75


Pump Control Panels<br />

Standard Pump Panel with Solid State Overload, Class 87<br />

Ordering Information<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-152.<br />

Wiring Diagrams see page 17-169.<br />

Replacement Parts see page 17-120.<br />

Sizes 1-4 will be supplied standard with a 240/480 volt coil. To<br />

change the coil voltage, change the 8th character in the catalog<br />

number to the letter shown in the coil table.<br />

Sizes 5 & 6 will be supplied standard with a 480 volt coil. To change<br />

the coil voltage, change the 8th character in the catalog number to<br />

the letter shown in the coil table.<br />

Coil Table<br />

60Hz Voltage<br />

Selection<br />

Letter<br />

24 J<br />

120 F<br />

110–120/220–240 A a<br />

200–208 D<br />

220–240 G<br />

220–240/440–480 C a<br />

277 L<br />

440–480 H<br />

550–600 E<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Fusible Disconnect<br />

Max Hp<br />

200<br />

Volts<br />

230<br />

Volts<br />

460<br />

Volts<br />

575<br />

Volts<br />

NEMA<br />

Size<br />

Half<br />

Size<br />

Overload<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

Disc.<br />

Amp<br />

Range<br />

Fuse<br />

Clip<br />

Amp / Volts<br />

Catalog<br />

Number<br />

— — 1 1 1 — 0.75–3.4 b A 30 30A/600V 87DUB6FC<br />

— — 5 5 1 — 3–12 A1 30 30A/600V 87DUC6FC<br />

— — 10 10 1 — 5.5–22 A1 30 30A/600V 87DUD6FC<br />

— — 10 10 1 — 5.5–22 A1 60 60A/600V 87DUD60C<br />

— — 15 15 — 1 3 ⁄4 10–40 A1 30 30A/600V 87EUE6FC<br />

— — 15 15 — 1 3 ⁄4 10–40 A1 60 60A/600V 87EUE60C<br />

— — 25 25 2 — 13–52 B 60 60A/600V 87FUF6FC<br />

— — 25 25 2 — 13–52 B 100 100A/600V 87FUF60C<br />

— — 30 30 — 2 1 ⁄2 25–100 B 60 60A/600V 87GUG6FC<br />

— — 30 30 — 2 1 ⁄2 25–100 B 100 100A/600V 87GUG60C<br />

— — 50 50 3 — 25–100 B 100 100A/600V 87HUG6FC<br />

— — 50 50 3 — 25–100 B 200 200A/600V 87HUG60C<br />

— — 75 75 — 3 1 ⁄2 50–200 B 200 200A/600V 87IUH6FC<br />

— — 100 100 4 — 50–200 B 200 200A/600V 87JUH6FC<br />

— — 200 200 5 — 55–250 — 400 400A/600V 87LPU6FH<br />

— — 250 — 6 — 160–630 — 600 600A/600V 87MSW6FH<br />

2 2 — — 1 — 3–12 A1 30 30A/250V 87DUC6LC<br />

3 3 — — 1 — 5.5–22 A1 30 30A/250V 87DUD6LC<br />

7 1 ⁄2 7 1 ⁄2 — — 1 — 10–40 A1 30 30A/250V 87DUE6LC<br />

7 1 ⁄2 7 1 ⁄2 — — 1 — 10–40 A1 60 60A/250V 87DUE6PC<br />

10 10 — — — 1 3 ⁄4 10–40 A1 60 60A/250V 87EUE6LC<br />

10 15 — — 2 — 13–52 B 60 60A/250V 87FUF6LC<br />

10 15 — — 2 — 13–52 B 100 100A/250V 87FUF6PC<br />

15 20 — — — 2 1 ⁄2 25–100 B 60 60A/250V 87GUG6LC<br />

15 20 — — — 2 1 ⁄2 25–100 B 100 100A/250V 87GUG6PC<br />

20 30 — — 3 — 25–100 B 100 100A/250V 87HUG6LC<br />

25 30 — — 3 — 25–100 B 200 200A/250V 87HUG6PC<br />

30 40 — — — 3 1 ⁄2 50–200 B 200 200A/250V 87IUH6LC<br />

40 50 — — 4 — 50–200 B 200 200A/250V 87JUH6LC<br />

75 100 — — 5 — 55–250 — 400 400A/250V 87LPU6LG<br />

Circuit Breaker<br />

Max Hp<br />

Overload<br />

Motor Circuit<br />

200<br />

Volts<br />

230<br />

Volts<br />

460<br />

Volts<br />

575<br />

Volts<br />

NEMA<br />

Size<br />

Half<br />

Size<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

Interrupter<br />

ETI Amps<br />

Catalog<br />

Number<br />

1<br />

⁄2<br />

1<br />

⁄2 1 1 1 — 0.75–3.4 b A 3 87DUB6MC<br />

2 2 5 5 1 — 3–12 A1 10 87DUC6MC<br />

3 3 10 10 1 — 5.5–22 A1 25 87DUD6MC<br />

7 1 ⁄2 7 1 ⁄2 10 — 1 — 10–40 A1 30 87DUE6MC<br />

— — 15 15 — 1 3 ⁄4 10–40 A1 40 87EUE6MC<br />

10 15 25 25 2 — 13–52 B 50 87FUF6MC<br />

15 20 30 30 — 2 1 ⁄2 25–100 B 100 87GUG6MC<br />

25 30 50 50 3 — 25–100 B 100 87HUG6MC<br />

30 40 75 75 — 3 1 ⁄2 50–200 B 125 87IUH6MC<br />

40 50 100 100 4 — 50–200 B 150 87JUH6MC<br />

50 75 150 200 5 — 55–250 — 250 87LPT6MH<br />

75 100 200 200 5 — 55–250 — 400 87LPU6MH<br />

100 125 250 300 6 — 160–630 — 400 87MSW6MH<br />

150 200 400 400 6 — 160–630 — 600 87MSX6MH<br />

List<br />

Price $<br />

List<br />

Price $<br />

Note: All starter sizes carry one maximum Hp rating (per<br />

the National Electric Code).<br />

a Not available on Size 5 and larger.<br />

b For an overload amp range of 0.25-1A, change the<br />

5th character from a ‘B’ to an ‘A’.<br />

A version with coil code A is also stocked via<br />

Controls Express.<br />

17-76<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Vacuum Break and Oil Well Pump Control Panels<br />

Class 87<br />

Revised on 01/31/20<br />

Selection<br />

Ordering Information<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-152.<br />

Wiring Diagrams see page 17-169.<br />

Replacement Parts see page 17-120.<br />

Replace the (*) in the catalog number with a letter from the coil table.<br />

Refer to page 17-38 for information on the 958L OLR<br />

Coil Table<br />

60Hz Voltage<br />

24 J<br />

120 F<br />

200–208 D<br />

220–240 G<br />

277 L<br />

440–480 H<br />

550–600 E<br />

Letter<br />

Vacuum Break Pump Control Panels (Vacuum Contactor with Trip Class 10 Solid-State Overload Relay)<br />

Max Hp<br />

Fusible Disconnect<br />

Circuit Breaker<br />

480 Volts<br />

575<br />

Volts<br />

NEMA<br />

Size<br />

Overload Relay<br />

Range<br />

Fuse Clip<br />

Amps/Volts Catalog Number MCI Amps Catalog Number<br />

100 100 4 50-200A a 200A/600V 87JCN6F* 250A 87JCN6M*<br />

100 100 4 55-250A 200A/600V 87JCM6F* 250A 87JCM6M*<br />

200 200 5 55-250A 400A/600V 87LCU6F* 400A 87LCT6M*<br />

250 300 6 160-630A — — 400A 87MCW6M*<br />

400 400 6 160-630A — — 600A 87MCX6M*<br />

Oil Well Pump Control Panels (Open Air Contactor with 958L Solid-State Overload Relay)<br />

Max Hp<br />

Fusible Disconnect<br />

Circuit Breaker<br />

480 Volts<br />

575<br />

Volts<br />

NEMA<br />

Size<br />

Overload Relay<br />

Range<br />

Fuse Clip<br />

Amps/Volts Catalog Number MCI Amps Catalog Number<br />

25 25 2 13-52 60A/600V 87FPI6F* 50 87FPI6M*<br />

50 50 3 25-100 100A/600V 87HPK6F* 100 87HPK6M*<br />

100 100 4 50-200 200A/600V 87JPM6F* 150 87JPM6M*<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Note: Hp’s shown above are based on the overload amp<br />

range for the FLA’s (per the National Electric Code)<br />

of typical industrial motors. All starter sizes carry<br />

one maximum Hp rating.<br />

a ESP200 overload relay.<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-77


Reduced Voltage Pump Panels<br />

Auto Transformer & Part winding (2 Step) with Solid State Overload, Class 88<br />

Revised on 03/31/20<br />

Selection<br />

Auto Transformer<br />

Part Winding<br />

Ordering Information<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-152.<br />

Wiring Diagrams see pages 17-162 and 17-163.<br />

Replacement Parts see page 17-120.<br />

Coil & Control Voltage<br />

The coil voltage on the<br />

contactors will be the<br />

motor voltage. A CPT will<br />

be supplied to provide the<br />

control voltage. The control<br />

voltage will be 120V.<br />

To change the control<br />

voltage to customer<br />

supplied (no CPT included),<br />

change the 9th character to<br />

the following:<br />

for 24V , use ”J”<br />

for 120V, use ”F”<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Auto Transformer Type<br />

Motor<br />

Voltage<br />

230<br />

460<br />

Overload<br />

Fusible Disconnect<br />

Circuit Breaker<br />

Max<br />

Hp<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

NEMA<br />

Size<br />

Half<br />

Size<br />

Fuse Clip Size<br />

Amps/Volts<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Circuit Breaker<br />

Amps<br />

Catalog<br />

Number<br />

15 13–52 B 2 — 60A/250V 88FUFT2FG 50 88FUFT2MG<br />

20 25–100 B — 2 1 ⁄2 100A/250V 88GUGT2FG 100 88GUGT2MG<br />

30 25–100 B 3 — 100A/250V 88HUGT2FG 100 88HUGT2MG<br />

40 50–200 B — 3 1 ⁄2 200A/250V 88IUHT2FG 125 88IUHT2MG<br />

50 50–200 B 4 — 200A/250V 88JUHT2FG 150 88JUHT2MG<br />

75 55–250 — 5 — — — 250 88LPST2MG<br />

100 55–250 — 5 — 400A/250V 88LPUT2FG 400 88LPUT2MG<br />

200 160–630 — 6 — — — 600 88MSXT2MG<br />

25 13–52 B 2 — 60A/600V 88FUFT4FH 50 88FUFT4MH<br />

30 25–100 B — 2 1 ⁄2 60A/600V 88GUGT4FH 50 88GUGT4MH<br />

50 25–100 B 3 — 100A/600V 88HUGT4FH 100 88HUGT4MH<br />

75 50–200 B — 3 1 ⁄2 200A/600V 88IUHT4FH 125 88IUHT4MH<br />

100 50–200 B 4 — 200A/600V 88JUHT4FH 150 88JUHT4MH<br />

150 55–250 — 5 — — — 250 88LPST4MH<br />

200 55–250 — 5 — 400A/600V 88LPST4FH 400 88LPUT4MH<br />

250 160–630 — 6 — — — 400 88MSVT4MH<br />

400 160–630 — 6 — 600A/600V 88MSXT4FH 600 88MSXT4MH<br />

Part Winding 2 Step<br />

Motor<br />

Voltage<br />

230<br />

460<br />

Overload<br />

Fusible Disconnect<br />

Circuit Breaker<br />

Max<br />

Hp<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

NEMA<br />

Size<br />

Half<br />

Size<br />

Fuse Clip Size<br />

Amps/Volts<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Circuit Breaker<br />

Amps<br />

Catalog<br />

Number<br />

20 10–40 A1 — 1 3 ⁄4 100A/250V 88EUEP2FG 100 88EUEP2MG<br />

25 13–52 B 2 — 100A/250V 88FUFP2FG 100 88FUFP2MG<br />

40 25–100 B — 2 1 ⁄2 200A/250V 88GUGP2FG 100 88GUGP2MG<br />

50 25–100 B 3 — 200A/250V 88HUGP2FG 150 88HUGP2MG<br />

60 50–200 B — 3 1 ⁄2 200A/250V 88IUHP2FG 250 88IUHP2MG<br />

75 50–200 B 4 — 400A/250V 88JUHP2FG 250 88JUHP2MG<br />

125 55–250 — 5 — — — 400 88LPSP2MG<br />

150 55–250 — 5 — 600A/250V 88LPUP2FG 600 88LPUP2MG<br />

30 10–40 A1 — 1 3 ⁄4 100A/600V 88EUEP4FH 100 88EUEP4MH<br />

40 13–52 B 2 — 100A/600V 88FUFP4FH 100 88FUFP4MH<br />

60 25–100 B — 2 1 ⁄2 200A/600V 88GUGP4FH 100 88GUGP4MH<br />

75 25–100 B 3 — 200A/600V 88HUGP4FH 150 88HUGP4MH<br />

100 50–200 B — 3 1 ⁄2 200A/600V 88IUHP4FH 250 88IUHP4MH<br />

150 50–200 B 4 — 400A/600V 88JUHP4FH 250 88JUHP4MH<br />

250 55–250 — 5 — — — 400 88LPSP4MH<br />

350 55–250 — 5 — 600A/600V 88LPUP4FH 600 88LPUP4MH<br />

List<br />

Price $<br />

List<br />

Price $<br />

Note: All starter sizes carry one maximum Hp rating (per the National Electric Code).<br />

17-78<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Reduced Voltage Pump Panels<br />

Wye Delta with Solid State Overload, Class 88<br />

Revised on 03/31/20<br />

Selection<br />

Ordering Information<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-152.<br />

Wiring Diagrams see pages 17-164 and 17-165.<br />

Replacement Parts see page 17-120.<br />

Coil & Control Voltage<br />

The coil voltage on the contactors<br />

will be the motor voltage. A<br />

CPT will be supplied to provide<br />

the control voltage. The control<br />

voltage will be 120V.<br />

To change the control voltage<br />

to customer supplied (no CPT<br />

included), change the 9th<br />

character to the following:<br />

for 24V , use ”J”<br />

for 120V, use ”F”<br />

Wye Delta<br />

Motor<br />

Voltage<br />

200<br />

230<br />

460<br />

575<br />

Max<br />

Hp<br />

Overload<br />

Amp<br />

Range<br />

Frame<br />

Size<br />

NEMA<br />

Size<br />

Half<br />

Size<br />

Fuse Clip Size<br />

Amps/Volts<br />

Motor<br />

Circuit<br />

Interruter<br />

ETI Amps<br />

Open Transition<br />

Closed Transition<br />

Fusible Disconnect Circuit Breaker Fusible Disconnect Circuit Breaker<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Catalog<br />

Number<br />

10 10–40 A1 1 — 60A/250V 50 88DUE06FD 88DUE06MD 88DUEC6FD 88DUEC6MD<br />

15 10–40 A1 — 1 3 ⁄4 100A/250V 100 88EUE06FD 88EUE06MD 88EUEC6FD 88EUEC6MD<br />

20 13–52 B 2 — 100A/250V 100 88FUF06FD 88FUF06MD 88FUFC6FD 88FUFC6MD<br />

30 25–100 B — 2 1 ⁄2 200A/250V 125 88GUG06FD 88GUG06MD 88GUGC6FD 88GUGC6MD<br />

40 25–100 B 3 — 200A/250V 150 88HUG06FD 88HUG06MD 88HUGC6FD 88HUGC6MD<br />

50 50–200 B — 3 1 ⁄2 200A/250V 250 88IUH06FD 88IUH06MD 88IUHC6FD 88IUHC6MD<br />

60 50–200 B 4 — 400A/250V 250 88JUH06FD 88JUH06MD 88JUHC6FD 88JUHC6MD<br />

75 55–250 — 5 — 400A/250V 400 88LPS06FD 88LPS06MD 88LPSC6FD 88LPSC6MD<br />

150 55–250 — 5 — 600A/250V 600 88LPU06FD 88LPU06MD 88LPUC6FD 88LPUC6MD<br />

300 160–630 — 6 — — 800 — 88MSX06MD — 88MSXC6MD<br />

10 10–40 A1 1 — 60A/250V 50 88DUE02FG 88DUE02MG 88DUEC2FG 88DUEC2MG<br />

15 10–40 A1 — 1 3 ⁄4 60A/250V 50 88EUE02FG 88EUE02MG 88EUEC2FG 88EUEC2MG<br />

25 13–52 B 2 — 100A/250V 100 88FUF02FG 88FUF02MG 88FUFC2FG 88FUFC2MG<br />

30 25–100 B — 2 1 ⁄2 200A/250V 100 88GUG02FG 88GUG02MG 88GUGC2FG 88GUGC2MG<br />

50 25–100 B 3 — 200A/250V 150 88HUG02FG 88HUG02MG 88HUGC2FG 88HUGC2MG<br />

60 50–200 B — 3 1 ⁄2 200A/250V 250 88IUH02FG 88IUH02MG 88IUHC2FG 88IUHC2MG<br />

75 50–200 B 4 — 400A/250V 250 88JUH02FG 88JUH02MG 88JUHC2FG 88JUHC2MG<br />

100 55–250 — 5 — 400A/250V 400 88LPS02FG 88LPS02MG 88LPSC2FG 88LPSC2MG<br />

150 55–250 — 5 — 600A/250V 600 88LPU02FG 88LPU02MG 88LPUC2FG 88LPUC2MG<br />

350 160–630 — 6 — — 1200 — 88MSX02MG — 88MSXC2MG<br />

15 5.5-22 A1 1 — 30A/600V 30 88DUD04FH 88DUD04MH 88DUDC4FH 88DUDC4MH<br />

30 10–40 A1 — 1 3 ⁄4 60A/600V 50 88EUE04FH 88EUE04MH 88EUEC4FH 88EUEC4MH<br />

40 13–52 B 2 — 100A/600V 100 88FUF04FH 88FUF04MH 88FUFC4FH 88FUFC4MH<br />

60 25–100 B — 2 1 ⁄2 200A/600V 100 88GUG04FH 88GUG04MH 88GUGC4FH 88GUGC4MH<br />

75 25–100 B 3 — 200A/600V 125 88HUG04FH 88HUG04MH 88HUGC4FH 88HUGC4MH<br />

100 50–200 B — 3 1 ⁄2 200A/600V 150 88IUH04FH 88IUH04MH 88IUHC4FH 88IUHC4MH<br />

150 50–200 B 4 — 400A/600V 250 88JUH04FH 88JUH04MH 88JUHC4FH 88JUHC4MH<br />

200 55–250 — 5 — 400A/600V 400 88LPS04FH 88LPS04MH 88LPSC4FH 88LPSC4MH<br />

300 55–250 — 5 — 600A/600V 600 88LPU04FH 88LPU04MH 88LPUC4FH 88LPUC4MH<br />

700 160–630 — 6 — — 1200 — 88MSX04MH — 88MSXC4MH<br />

15 5.5-22 A1 1 — 30A/600V 30 88DUD05FE 88DUD05ME 88DUDC5FE 88DUDC5ME<br />

30 10–40 A1 — 1 3 ⁄4 60A/600V 50 88EUE05FE 88EUE05ME 88EUEC5FE 88EUEC5ME<br />

40 13–52 B 2 — 100A/600V 50 88FUF05FE 88FUF05ME 88FUFC5FE 88FUFC5ME<br />

60 25–100 B — 2 1 ⁄2 200A/600V 100 88GUG05FE 88GUG05ME 88GUGC5FE 88GUGC5ME<br />

75 25–100 B 3 — 200A/600V 125 88HUG05FE 88HUG05ME 88HUGC5FE 88HUGC5ME<br />

100 50–200 B — 3 1 ⁄2 200A/600V 150 88IUH05FE 88IUH05ME 88IUHC5FE 88IUHC5ME<br />

150 50–200 B 4 — 400A/600V 250 88JUH05FE 88JUH05ME 88JUHC5FE 88JUHC5ME<br />

200 55–250 — 5 — 400A/600V 400 88LPS05FE 88LPU05ME 88LPSC5FE 88LPSC5ME<br />

300 55–250 — 5 — 600A/600V 400 88LPU05FE 88LPU05ME 88LPUC5FE 88LPUC5ME<br />

700 160–630 — 6 — — 1200 — 88MSX05ME — 88MSXC5ME<br />

List<br />

Price $<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Note: All starter sizes carry one maximum Hp rating (per the National Electric Code).<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-79


Pump Control Panels<br />

Notes<br />

CONTROL<br />

PRODUCTS<br />

17<br />

NEMA & General<br />

Purpose Control<br />

17-80<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Lighting and Heating Control<br />

Electrically Held Lighting Contactors, Class LE<br />

Revised on 05/31/19<br />

Features<br />

Simplicity and compact lightweight design makes Class LE<br />

lighting contactors an attractive solution to your budgeting<br />

challenges.<br />

NEMA & General<br />

Purpose Control<br />

• Used in applications where it is not critical that contacts<br />

remain closed if control power is lost<br />

• Rated for tungsten lighting (incandescent filament),<br />

ballast lighting (fluorescent, HID, metal halide, mercury<br />

vapor, quartz halogen and sodium-lamp), resistive and<br />

general use loads<br />

• Contacts are rated 20 - 400 amps at 600 volts<br />

• 3 and 4 pole (up to 12 pole for 30 and 60 amp contactors)<br />

• Most contactors have built-in auxiliary contacts for<br />

convenient 3-wire control<br />

• Combination lighting contactors are UL Listed for Service<br />

Entrance<br />

• Wide range of coil voltages from 24 to 600 VAC 50/60Hz<br />

• Compact design allows for smaller panels and more<br />

wiring room<br />

• Finger and back-of-hand safe terminals<br />

• Panel and DIN rail mounting<br />

• Full line of enclosures including NEMA 1, 3/3R, 4, 4/4X<br />

stainless steel and 12<br />

• Available in combination form with choice of non-fusible<br />

disconnect, fusible disconnect or circuit breaker<br />

• Full line of factory and field modifications<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-81


Lighting and Heating Control<br />

Electrically Held Lighting Contactors, Class LE<br />

Revised on 03/31/20<br />

Features<br />

Catalog Numbering System<br />

LE 0<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Disconnect Type<br />

B = Combination Circuit Breaker<br />

D = Combination Non-Fused Disconnect<br />

F = Combination Fusible Disconnect<br />

N = Non-Combination<br />

Disconnect Rating<br />

0 = N/A<br />

A = 30A/250V Disconnect<br />

B = 30A/600V Disconnect<br />

C = 60A/250V Disconnect<br />

D = 60A/600V Disconnect<br />

E = 100A/250V Disconnect<br />

F = 100A/600V Disconnect<br />

G = 200A/250V Disconnect<br />

H = 200A/600V Disconnect<br />

J = 400A/250V Disconnect<br />

K = 400A/600V Disconnect<br />

T = 20A Circuit Breaker<br />

V = 30A Circuit Breaker<br />

Y = 60A Circuit Breaker<br />

Z = 100A Circuit Breaker<br />

Enclosure Type<br />

0 = Open<br />

1 = NEMA 1<br />

2 = NEMA 12/3R<br />

4 = NEMA 4/4X SS<br />

Contactor Rating (Amp)<br />

B = 20<br />

C = 30<br />

D = 60<br />

E = 100<br />

F = 200<br />

G = 300<br />

H = 400<br />

N.C. Poles<br />

0 = None<br />

N.O. Poles<br />

03 = Three<br />

04 = Four<br />

06 = Six<br />

09 = Nine<br />

12 = Twelve<br />

Coil Voltage (AC 60Hz)<br />

024 = 24<br />

120 = 120<br />

208 = 208<br />

240 = 240<br />

277 = 277<br />

347 = 347<br />

480 = 480<br />

600 = 600<br />

Series<br />

A = 200 – 400A Contactors<br />

B = 20 & 30A Contactors<br />

C = 60 & 100A Contactors<br />

17-82<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Lighting and Heating Control<br />

Electrically Held Lighting Contactors, Class LE<br />

Revised on 03/31/20<br />

Selection<br />

Ordering Information<br />

Replace *** with a number from the coil table.<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-135 for open,<br />

page 17-153 for enclosed.<br />

Wiring Diagram see page 17-170.<br />

Replacement Parts see page 17-123.<br />

Coil Table<br />

VAC 60Hz ***<br />

24 024<br />

120 120<br />

208 208<br />

240 240<br />

277 277<br />

347 a 347<br />

480 480<br />

600 600<br />

Replace the (***) with a number from<br />

the coil table.<br />

Non-Combination Contactor<br />

Enclosure Type<br />

Normally Normally<br />

Max. Amp Number Closed Open Open 1 3/3R/12 4/4X 304 S.S.<br />

Rating of Poles Contacts Contacts Catalog Number<br />

20<br />

3 0 3 LEN00B003***B LEN01B003***B LEN02B003***B LEN04B003***B<br />

4 0 4 LEN00B004***B LEN01B004***B LEN02B004***B LEN04B004***B<br />

3 0 3 LEN00C003***B LEN01C003***B LEN02C003***B LEN04C003***B<br />

4 0 4 LEN00C004***B LEN01C004***B LEN02C004***B LEN04C004***B<br />

30<br />

6 0 6 LEN00C006***B LEN01C006***B LEN02C006***B LEN04C006***B<br />

9 0 9 LEN00C009***B LEN01C009***B LEN02C009***B LEN04C009***B<br />

12 0 12 LEN00C012***B LEN01C012***B LEN02C012***B LEN04C012***B<br />

3 0 3 LEN00D003***C LEN01D003***C LEN02D003***C LEN04D003***C<br />

60<br />

6 0 6 LEN00D006***C LEN01D006***C LEN02D006***C LEN04D006***C<br />

9 0 9 LEN00D009***C LEN01D009***C LEN02D009***C LEN04D009***C<br />

12 0 12 LEN00D012***C LEN01D012***C LEN02D012***C LEN04D012***C<br />

100 3 0 3 LEN00E003***C LEN01E003***C LEN02E003***C LEN04E003***C<br />

200 3 0 3 LEN00F003***A LEN01F003***A LEN02F003***A LEN04F003***A<br />

300 3 0 3 LEN00G003***A LEN01G003***A LEN02G003***A LEN04G003***A<br />

400 3 0 3 LEN00H003***A LEN01H003***A LEN02H003***A LEN04H003***A<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

a Not available on 60 - 400A contactors.<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-83


Lighting and Heating Control<br />

Electrically Held Lighting Contactors, Class LE<br />

Revised on 03/31/20<br />

Technical Data<br />

Contactor LEN00B003 LEN00B004 LEN00C003 LEN00C004<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

General technical data:<br />

Finger-safe (main circuit / control circuit) yes / yes yes / yes yes / yes yes / yes<br />

Altitude (m) 2,000 2,000 2,000 2,000<br />

Ambient storage temperature (°C) -55 to 80 -55 to 80 -55 to 80 -55 to 80<br />

Ambient operating temperature (°C) 0 to 40 0 to 40 0 to 40 0 to 40<br />

Humidity (% non-condensing) 10 to 95 10 to 95 10 to 95 10 to 95<br />

Shock resistance at rectangular impulse (g/ms) 6.7 / 5, 4.2 / 10 6.7 / 5, 4.2 / 10 7.5 / 5, 4.7 / 10 7.5 / 5, 4.7 / 10<br />

Shock resistance at sine pulse (g/ms) 10.5 / 5, 6.6 / 10 10.5 / 5, 6.6 / 10 11.8 / 5, 7.4 / 10 11.8 / 5, 7.4 / 10<br />

Mechanical operating cycles as operating time:<br />

of contactor 30,000,000 30,000,000 10,000,000 10,000,000<br />

of contactor with additional aux contacts 10,000,000 10,000,000 10,000,000 10,000,000<br />

Main circuit:<br />

Number of NC / NO main contacts 0NC / 3NO 0NC / 4NO 0NC / 3NO 0NC / 4NO<br />

Typical power loss per conductor (W) 0.7 0.7 0.9 0.9<br />

Off-load operating frequency (cycles per hour) 10,000 10,000 5,000 5,000<br />

Current ratings:<br />

Tungsten (poles per phase)<br />

Ballast (poles per phase)<br />

General and resistive (poles per phase)<br />

Coil ratings:<br />

20A @277V 1p 1ph<br />

20A @480V 2p 1ph<br />

20A @480V 3p 3ph<br />

20A @347V 1p 1ph<br />

20A @600V 2p 1ph<br />

20A @600V 3p 3ph<br />

20A @600V 1p 1ph<br />

20A @600V 2p 1ph<br />

20A @600V 3p 3ph<br />

20A @277V 1p 1ph<br />

20A @480V 2p 1ph<br />

20A @480V 3p 3ph<br />

20A @347V 1p 1ph<br />

20A @600V 2p 1ph<br />

20A @600V 3p 3ph<br />

20A @600V 1p 1ph<br />

20A @600V 2p 1ph<br />

20A @600V 3p 3ph<br />

30A @277V 1p 1ph<br />

30A @480V 2p 1ph<br />

30A @480V 3p 3ph<br />

30A @347V 1p 1ph<br />

30A @600V 2p 1ph<br />

30A @660V 3p 3ph<br />

30A @600V 1p 1ph<br />

30A @600V 2p 1ph<br />

30A @600V 3p 3ph<br />

Nominal voltage 2) 2) 2) 2)<br />

Inrush / sealed power (VA) 31.7 / 4.8 31.7 / 4.8 87 / 9.4 87 / 9.4<br />

Coil voltage tolerance factor 0.8 - 1.1 0.8 - 1.1 0.8 - 1.1 0.8 - 1.1<br />

Internal/standard auxiliary contact:<br />

30A @277V 1p 1ph<br />

30A @480V 2p 1ph<br />

30A @480V 3p 3ph<br />

30A @347V 1p 1ph<br />

30A @600V 2p 1ph<br />

30A @600V 3p 3ph<br />

30A @600V 1p 1ph<br />

30A @600V 2p 1ph<br />

30A @600V 3p 3ph<br />

Number of NC / NO auxiliary contacts 0NC / 1NO NA 1NC / 1NO 1NC / 1NO<br />

Rating A600 / Q600 NA A600 / Q600 A600 / Q600<br />

Installation/mounting/dimensions:<br />

Mounting orientation vertical vertical vertical vertical<br />

Type of mounting: screw / DIN rail yes / yes yes / yes yes / yes yes / yes<br />

Height x Width x Depth (mm) 57.5 x 45 x 73 57.5 x 45 x 73 85 x 45 x 97 85 x 60 x 97<br />

Minimum clearance to sides (mm) 0 0 0 0<br />

Minimum clearance to earthed parts (mm) 6 6 6 6<br />

Connection type / torque for main circuit terminals screw / 7-10 lb in screw / 7-10 lb in screw / 18-22 lb in screw / 18-22 lb in<br />

Connection type / torque for control circuit terminals screw / 7-10 lb in screw / 7-10 lb in screw / 7-10 lb in screw / 7-10 lb in<br />

Solid and stranded conductors for<br />

main contacts (AWG)<br />

Solid and stranded conductors for<br />

control circuit (AWG)<br />

2x(20-16),<br />

2x(18-14), 2x(12)<br />

2x(20-16),<br />

2x(18-14)<br />

2x(20-16),<br />

2x(18-14), 2x(12)<br />

2x(20-16),<br />

2x(18-14)<br />

2x(6-12),<br />

2x(14-8)<br />

2x(20-16),<br />

2x(18-14)<br />

2x(6-12),<br />

2x(14-8)<br />

2x(20-16),<br />

2x(18-14)<br />

Conductor type for main and control circuits 75°C CU 75°C CU 75°C CU 75°C CU<br />

Short circuit current rating of main circuit:<br />

Short circuit current rating 5kA @ 600V 5kA @ 600V 5kA @ 600V 5kA @ 600V<br />

Max fuse / circuit breaker (Amp) 30 / 25 30 / 25 60 / 40 60 / 40<br />

Certificates: cULus cULus cULus cULus<br />

Must use an external (optional) auxiliary contact.<br />

2) Refer to catalog selection tables for coil voltages.<br />

17-84<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Lighting and Heating Control<br />

Electrically Held Lighting Contactors, Class LE<br />

Revised on 03/31/20<br />

Technical Data<br />

LEN00D003 LEN00E003 LEN00F003 LEN00G003 LEN00H003<br />

no / yes no / yes no / yes no / yes no / yes<br />

2,000 2,000 2,000 2,000 2,000<br />

-55 to 80 -55 to 80 -55 to 80 -55 to 80 -55 to 80<br />

0 to 40 0 to 40 0 to 40 0 to 40 0 to 40<br />

10 to 95 10 to 95 10 to 95 10 to 95 10 to 95<br />

11.8 / 5, 7.4 / 10 6.7 / 5, 4 / 10 8.5 / 5, 4.2 / 10 8.5 / 5, 4.2 / 10 8.5 / 5, 4.2 / 10<br />

18.5 / 5, 10 / 10 10.6 / 5, 6.3 / 10 13.4 / 5, 6.5 / 10 13.4 / 5, 6.5 / 10 13.4 / 5, 6.5 / 10<br />

Mechanical operating cycles as operating time:<br />

10,000,000 10,000,000 10,000,000 10,000,000 10,000,000<br />

10,000,000 10,000,000 10,000,000 10,000,000 10,000,000<br />

Main circuit:<br />

0NC / 3NO 0NC / 3NO 0NC / 3NO 0NC / 3NO 0NC / 3NO<br />

3.8 5.3 13 18 35<br />

5,000 5,000 2,000 2,000 2,000<br />

Current ratings:<br />

60A @277V 1p 1ph<br />

60A @480V 2p 1ph<br />

60A @480V 3p 3ph<br />

60A @347V 1p 1ph<br />

60A @600V 2p 1ph<br />

60A @600V 3p 3ph<br />

60A @347V 1p 1ph<br />

60A @600V 2p 1ph<br />

60A @600V 3p 3ph<br />

Coil ratings:<br />

100A @277V 1p 1ph<br />

100A @480V 2p 1ph<br />

100A @480V 3p 3ph<br />

100A @347V 1p 1ph<br />

100A @600V 2p 1ph<br />

100A @600V 3p 3ph<br />

100A @347V 1p 1ph<br />

100A @600V 2p 1ph<br />

100A @600V 3p 3ph<br />

200A @277V 1p 1ph<br />

200A @480V 2p 1ph<br />

200A @480V 3p 3ph<br />

200A @600V 1p 1ph<br />

200A @600V 2p 1ph<br />

200A @600V 3p 3ph<br />

200A @600V 1p 1ph<br />

200A @600V 2p 1ph<br />

200A @600V 3p 3ph<br />

300A @277V 1p 1ph<br />

300A @480V 2p 1ph<br />

300A @480V 3p 3ph<br />

300A @600V 1p 1ph<br />

300A @600V 2p 1ph<br />

300A @600V 3p 3ph<br />

300A @600V 1p 1ph<br />

300A @600V 2p 1ph<br />

300A @600V 3p 3ph<br />

400A @277V 1p 1ph<br />

400A @480V 2p 1ph<br />

400A @480V 3p 3ph<br />

400A @600V 1p 1ph<br />

400A @600V 2p 1ph<br />

400A @600V 3p 3ph<br />

400A@600V 1p 1ph<br />

400A @600V 2p 1ph<br />

400A @600V 3p 3ph<br />

2) 2) 2) 2) 2)<br />

188 / 16.5 326 / 22 300 / 5.8 590 / 6.7 830 / 9.2<br />

0.8 - 1.1 0.8 - 1.1 0.8 - 1.1 0.8 - 1.1 0.8 - 1.1<br />

Internal/standard auxiliary contact:<br />

1 N C / 1 N O 1 N C / 1 N O 2NC / 2NO 2NC / 2NO 2NC / 2NO<br />

A600 / P600 A600 / P600 A300 / Q300 A300 / Q300 A300 / Q300<br />

Installation/mounting/dimensions:<br />

vertical vertical vertical vertical vertical<br />

yes / yes yes / yes yes / no yes / no yes / no<br />

113 x 55 x 130 140 x 70 x 152 172 x 120 x 180 210 x 145 x 202 214 x 160 x 225<br />

6 6 10 10 10<br />

6 6 10 10 10<br />

screw / 26-39 lb in screw / 26-39 lb in screw / 90-110 lb in screw / 180-195 lb in screw / 180-195 lb in<br />

screw / 7-10 lb in screw / 7-10 lb in screw / 7-10 lb in screw / 7-10 lb in screw / 7-10 lb in<br />

2 x (18 ... 2),<br />

1 x (18 ... 1)<br />

2 x (18 ... 2),<br />

1 x (18 ... 1)<br />

2x(6-3/0) 2x(2/0-500MCM) 2x(2/0-500MCM)<br />

2x (20 ... 16),<br />

2x (18 ... 14)<br />

2 x (18 ... 2),<br />

1 x (18 ... 1)<br />

2x(18-14) 2x(18-14) 2x(18-14)<br />

75°C CU 75°C CU 75°C CU 75°C CU 75°C CU<br />

Short circuit current rating of main circuit:<br />

5kA @ 600V 10kA @ 600V 10kA @ 600V 18kA @ 600V 18kA @ 600V<br />

100 / 80 200 / 125 400 / 250 600 / 400 800 / 500<br />

cULus cULus cULus cULus cULus<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-85


Lighting and Heating Control<br />

Electrically Held Lighting Contactors, Class LE<br />

Revised on 08/31/18<br />

Selection<br />

Ordering Information<br />

Replace *** with a number from the coil table.<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-153.<br />

Wiring Diagram see page 17-170.<br />

Replacement Parts see page 17-123.<br />

Coil Table<br />

VAC 60Hz ***<br />

24 024<br />

120 120<br />

208 208<br />

240 240<br />

277 277<br />

347 347<br />

480 480<br />

600 600<br />

Replace the (***) with a number from<br />

the coil table.<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Combination Contactor<br />

Disconnect Type<br />

Non-Fusible<br />

Fusible<br />

Circuit Breaker<br />

Max.<br />

Amp<br />

Rating<br />

Number<br />

of NO<br />

Poles<br />

Disc.<br />

Amp<br />

Rating<br />

Disc Amp/<br />

Fuse Clip<br />

Rating<br />

Circuit<br />

Breaker<br />

Rating<br />

Enclosure Type<br />

1 3/3R/12, 4 4/4X 304 S.S.<br />

Catalog Number<br />

20 3 30A — — LEDB1B003***B LEDB2B003***B LEDB4B003***B<br />

30 3 30A — — LEDB1C003***B LEDB2C003***B LEDB4C003***B<br />

60 3 60A — — LEDD1D003***B LEDD2D003***B LEDD4D003***B<br />

100 3 100A — — LEDF1E003***B LEDF2E003***B LEDF4E003***B<br />

200 3 200A — — LEDH1F003***A LEDH2F003***A LEDH4F003***A<br />

300 3 400A — — LEDK1G003***A LEDK2G003***A LEDK4G003***A<br />

20<br />

30<br />

60<br />

100<br />

200<br />

300<br />

3 — 30A/250V — LEFA1B003***B LEFA2B003***B LEFA4B003***B<br />

3 — 30A/600V — LEFB1B003***B LEFB2B003***B LEFB4B003***B<br />

3 — 30A/250V — LEFA1C003***B LEFA2C003***B LEFA4C003***B<br />

3 — 30A/600V — LEFB1C003***B LEFB2C003***B LEFB4C003***B<br />

3 — 60A/250V — LEFC1D003***B LEFC2D003***B LEFC4D003***B<br />

3 — 60A/600V — LEFD1D003***B LEFD2D003***B LEFD4D003***B<br />

3 — 100A/250V — LEFE1E003***B LEFE2E003***B LEFE4E003***B<br />

3 — 100A/600V — LEFF1E003***B LEFF2E003***B LEFF4E003***B<br />

3 — 200A/250V — LEFG1F003***A LEFG2F003***A LEFG4F003***A<br />

3 — 200A/600V — LEFH1F003***A LEFH2F003***A LEFH4F003***A<br />

3 — 400A/250V — LEFJ1G003***A LEFJ2G003***A LEFJ4G003***A<br />

3 — 400A/600V — LEFK1G003***A LEFK2G003***A LEFK4G003***A<br />

20 3 — — 20A LEBT1B003***B LEBT2B003***B LEBT4B003***B<br />

30 3 — — 30A LEBV1C003***B LEBV2C003***B LEBV4C003***B<br />

60 3 — — 60A LEBY1D003***B LEBY2D003***B LEBY4D003***B<br />

100 3 — — 100A LEBZ1E003***B LEBZ2E003***B LEBZ4E003***B<br />

Not available on 200 - 400A contactors.<br />

Type 4 painted enclosure through 100 Amp only.<br />

17-86<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Lighting and Heating Control<br />

Electrically Held Lighting Contactors, Class LC<br />

Features<br />

Class LC lighting contactors deliver unprecedented versatility<br />

in application, simplicity in configuration and performance in<br />

operation. Ingenious design, rugged construction and a host<br />

of truly useful features make them uniquely appealing to all<br />

those who use them.<br />

Convenient side access<br />

field power wiring.<br />

Contact position indication – when<br />

button protrudes, contact is closed<br />

.<br />

Power poles can easily be added at<br />

any time based on changing needs.<br />

Furthermore, they may be converted<br />

from NO to NC (or vice versa) simply<br />

by repositioning.<br />

A simple kit easily<br />

converts electrically held<br />

units to mechanically<br />

held and includes a 2-<br />

or 3-wire control module.<br />

Plug-in auxiliary contacts<br />

are NO when installed on<br />

the left side of the contactor,<br />

NC on the right.<br />

Standard base enables<br />

contactor to be field<br />

expandable for flexibility<br />

and future needs.<br />

Finger and back-of-hand<br />

safe terminals.<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

• Used in all applications where either electrically or<br />

mechanically held contactors are specifically suited and<br />

also ideal for maximum flexibility and future expansion<br />

• Rated for tungsten lighting (incandescent filament), ballast<br />

lighting (fluorescent, HID, metal halide, mercury vapor, quartz<br />

halogen and sodium-lamp), resistive and general use loads<br />

• Contacts are rated up to 30 amps at 600 volts<br />

• Up to 12 poles (maximum of 8 normally closed)<br />

• Wide range of coil voltages from 24 to 600 VAC 50/60Hz<br />

• Can be ordered as either electrically or mechanically held and<br />

can also be converted from electrically to mechanically held<br />

in the field with a simple conversion kit<br />

• Modular design enables you to stock the building block<br />

components to assemble all configurations of both the<br />

electrically and mechanically held contactors thus<br />

dramatically reducing inventory<br />

• Full line of enclosures including NEMA 1, 3/3R, 4, 4/4X<br />

stainless steel and 12<br />

• Full line of factory and field modifications<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-87


Lighting and Heating Control<br />

Electrically Held Lighting Contactors, Class LC<br />

Features<br />

Catalog Numbering System<br />

LC E0 C A<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Controller Type<br />

E0 = Electrically Held<br />

(Convertible to MH)<br />

Enclosure Type<br />

0 = Open<br />

1 = NEMA 1<br />

2 = NEMA 12/3R<br />

4 = NEMA 4/4X Stainless Steel<br />

Contactor Rating (Amp)<br />

C = 30<br />

N.C. Poles<br />

0 = None<br />

1 = One<br />

2 = Two<br />

3 = Three<br />

4 = Four<br />

5 = Five<br />

6 = Six<br />

7 = Seven<br />

8 = Eight<br />

N.O. Poles<br />

00 = None<br />

01 = One<br />

02 = Two<br />

03 = Three<br />

04 = Four<br />

05 = Five<br />

06 = Six<br />

07 = Seven<br />

08 = Eight<br />

09 = Nine<br />

10 = Ten<br />

11 = Eleven<br />

12 = Twelve<br />

Coil Voltage<br />

024 = 24V 60Hz / 20V 50Hz<br />

120 = 115-120V 60Hz / 110V 50Hz<br />

208 = 200-208V 60Hz<br />

240 = 230-240V 60Hz / 220V 50Hz<br />

277 = 277V 60Hz / 240V 50Hz<br />

347 = 347V 60Hz<br />

480 = 460-480V 60Hz / 440V 50Hz<br />

600 = 575-600V 60Hz / 550V 50Hz<br />

17-88<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Lighting and Heating Control<br />

Electrically Held Lighting Contactors, Class LC<br />

Ordering Information<br />

To order standard electrically held contactor,<br />

simply select catalog number from tables below.<br />

To order mechanically held contactor, select<br />

catalog number from tables below and specify<br />

conversion module from factory modification<br />

section from page 17-117.<br />

To convert standard electrically held contactor<br />

to mechanically held in the field, select<br />

catalog number from tables below and select<br />

conversion module kit from field modification<br />

section on page 17-104.<br />

Replace *** with a number from the coil table.<br />

Field Modification Kits see page 17-102.<br />

Factory Modifications see page 17-114.<br />

Dimensions see page 17-134 open,<br />

page 17-153 enclosed.<br />

Wiring Diagrams see page 17-170.<br />

Replacement Parts see page 17-123.<br />

Revised on 08/31/18<br />

Coil Table<br />

Selection<br />

VAC 60Hz ***<br />

24 024<br />

120 120<br />

208 208<br />

240 240<br />

277 277<br />

347 347<br />

480 480<br />

600 600<br />

Replace the (***) with a number<br />

from the coil table.<br />

Non-Combination Contactor (30 Amp max.)<br />

Enclosure Type<br />

No. of Poles<br />

Open 1 3/3R/12 4/4X 304 S.S.<br />

N.C. N.O. Catalog Number<br />

2<br />

LCE00C200***A LCE01C200***A LCE02C200***A LCE04C200***A<br />

3 LCE00C300***A LCE01C300***A LCE02C300***A LCE04C300***A<br />

4 LCE00C400***A LCE01C400***A LCE02C400***A LCE04C400***A<br />

5 0 LCE00C500***A LCE01C500***A LCE02C500***A LCE04C500***A<br />

6 LCE00C600***A LCE01C600***A LCE02C600***A LCE04C600***A<br />

7 LCE00C700***A LCE01C700***A LCE02C700***A LCE04C700***A<br />

8 LCE00C800***A LCE01C800***A LCE02C800***A LCE04C800***A<br />

1<br />

LCE00C101***A LCE01C101***A LCE02C101***A LCE04C101***A<br />

2 LCE00C201***A LCE01C201***A LCE02C201***A LCE04C201***A<br />

3 LCE00C301***A LCE01C301***A LCE02C301***A LCE04C301***A<br />

4 LCE00C401***A LCE01C401***A LCE02C401***A LCE04C401***A<br />

1<br />

5 LCE00C501***A LCE01C501***A LCE02C501***A LCE04C501***A<br />

6 LCE00C601***A LCE01C601***A LCE02C601***A LCE04C601***A<br />

7 LCE00C701***A LCE01C701***A LCE02C701***A LCE04C701***A<br />

8 LCE00C801***A LCE01C801***A LCE02C801***A LCE04C801***A<br />

0<br />

LCE00C002***A LCE01C002***A LCE02C002***A LCE04C002***A<br />

1 LCE00C102***A LCE01C102***A LCE02C102***A LCE04C102***A<br />

2 LCE00C202***A LCE01C202***A LCE02C202***A LCE04C202***A<br />

3 LCE00C302***A LCE01C302***A LCE02C302***A LCE04C302***A<br />

4 2 LCE00C402***A LCE01C402***A LCE02C402***A LCE04C402***A<br />

5 LCE00C502***A LCE01C502***A LCE02C502***A LCE04C502***A<br />

6 LCE00C602***A LCE01C602***A LCE02C602***A LCE04C602***A<br />

7 LCE00C702***A LCE01C702***A LCE02C702***A LCE04C702***A<br />

8 LCE00C802***A LCE01C802***A LCE02C802***A LCE04C802***A<br />

0<br />

LCE00C003***A LCE01C003***A LCE02C003***A LCE04C003***A<br />

1 LCE00C103***A LCE01C103***A LCE02C103***A LCE04C103***A<br />

2 LCE00C203***A LCE01C203***A LCE02C203***A LCE04C203***A<br />

3 LCE00C303***A LCE01C303***A LCE02C303***A LCE04C303***A<br />

4 3 LCE00C403***A LCE01C403***A LCE02C403***A LCE04C403***A<br />

5 LCE00C503***A LCE01C503***A LCE02C503***A LCE04C503***A<br />

6 LCE00C603***A LCE01C603***A LCE02C603***A LCE04C603***A<br />

7 LCE00C703***A LCE01C703***A LCE02C703***A LCE04C703***A<br />

8 LCE00C803***A LCE01C803***A LCE02C803***A LCE04C803***A<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-89


Lighting and Heating Control<br />

Electrically Held Lighting Contactors, Class LC<br />

Revised on 08/31/18<br />

Selection<br />

Non-Combination Contactor (30 Amp max.)<br />

Enclosure Type<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

No. of Poles<br />

Open 1 3/3R/12 4/4X 304 S.S.<br />

N.C. N.O. Catalog Number<br />

0<br />

LCE00C004***A LCE01C004***A LCE02C004***A LCE04C004***A<br />

1 LCE00C104***A LCE01C104***A LCE02C104***A LCE04C104***A<br />

2 LCE00C204***A LCE01C204***A LCE02C204***A LCE04C204***A<br />

3 LCE00C304***A LCE01C304***A LCE02C304***A LCE04C304***A<br />

4 4 LCE00C404***A LCE01C404***A LCE02C404***A LCE04C404***A<br />

5 LCE00C504***A LCE01C504***A LCE02C504***A LCE04C504***A<br />

6 LCE00C604***A LCE01C604***A LCE02C604***A LCE04C604***A<br />

7 LCE00C704***A LCE01C704***A LCE02C704***A LCE04C704***A<br />

8 LCE00C804***A LCE01C804***A LCE02C804***A LCE04C804***A<br />

0<br />

LCE00C005***A LCE01C005***A LCE02C005***A LCE04C005***A<br />

1 LCE00C105***A LCE01C105***A LCE02C105***A LCE04C105***A<br />

2 LCE00C205***A LCE01C205***A LCE02C205***A LCE04C205***A<br />

3 5 LCE00C305***A LCE01C305***A LCE02C305***A LCE04C305***A<br />

4 LCE00C405***A LCE01C405***A LCE02C405***A LCE04C405***A<br />

5 LCE00C505***A LCE01C505***A LCE02C505***A LCE04C505***A<br />

6 LCE00C605***A LCE01C605***A LCE02C605***A LCE04C605***A<br />

0<br />

LCE00C006***A LCE01C006***A LCE02C006***A LCE04C006***A<br />

1 LCE00C106***A LCE01C106***A LCE02C106***A LCE04C106***A<br />

2 LCE00C206***A LCE01C206***A LCE02C206***A LCE04C206***A<br />

3 6 LCE00C306***A LCE01C306***A LCE02C306***A LCE04C306***A<br />

4 LCE00C406***A LCE01C406***A LCE02C406***A LCE04C406***A<br />

5 LCE00C506***A LCE01C506***A LCE02C506***A LCE04C506***A<br />

6 LCE00C606***A LCE01C606***A LCE02C606***A LCE04C606***A<br />

0<br />

LCE00C007***A LCE01C007***A LCE02C007***A LCE04C007***A<br />

1 LCE00C107***A LCE01C107***A LCE02C107***A LCE04C107***A<br />

2 7 LCE00C207***A LCE01C207***A LCE02C207***A LCE04C207***A<br />

3 LCE00C307***A LCE01C307***A LCE02C307***A LCE04C307***A<br />

4 LCE00C407***A LCE01C407***A LCE02C407***A LCE04C407***A<br />

0<br />

LCE00C008***A LCE01C008***A LCE02C008***A LCE04C008***A<br />

1 LCE00C108***A LCE01C108***A LCE02C108***A LCE04C108***A<br />

2 8 LCE00C208***A LCE01C208***A LCE02C208***A LCE04C208***A<br />

3 LCE00C308***A LCE01C308***A LCE02C308***A LCE04C308***A<br />

4 LCE00C408***A LCE01C408***A LCE02C408***A LCE04C408***A<br />

0<br />

LCE00C009***A LCE01C009***A LCE02C009***A LCE04C009***A<br />

1 9 LCE00C109***A LCE01C109***A LCE02C109***A LCE04C109***A<br />

2 LCE00C209***A LCE01C209***A LCE02C209***A LCE04C209***A<br />

0<br />

LCE00C010***A LCE01C010***A LCE02C010***A LCE04C010***A<br />

1 10 LCE00C110***A LCE01C110***A LCE02C110***A LCE04C110***A<br />

2 LCE00C210***A LCE01C210***A LCE02C210***A LCE04C210***A<br />

0 11 LCE00C011***A LCE01C011***A LCE02C011***A LCE04C011***A<br />

0 12 LCE00C012***A LCE01C012***A LCE02C012***A LCE04C012***A<br />

17-90<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Lighting and Heating Control<br />

Electrically Held Lighting Contactors, Class LC<br />

Technical Data<br />

General technical data:<br />

Finger-safe (main circuit / control circuit)<br />

yes / yes<br />

Degree of pollution 3<br />

Altitude (m) 2,000<br />

Ambient storage temperature (°C) -30 to 65<br />

Ambient operating temperature (°C) -25 to 40<br />

Humidity (% non-condensing)<br />

no data<br />

Shock resistance at rectangular impulse (g/ms)<br />

no data<br />

Shock resistance at sine pulse (g/ms)<br />

no data<br />

Rated impulse voltage resistance (kV)<br />

no data<br />

Rated insulation voltage (V) 600<br />

Mechanical operating cycles as operating time:<br />

of contactor 100,000<br />

of contactor with additional aux contacts 100,000<br />

Main circuit:<br />

Number of main contacts<br />

2 - 12 (maximum of 8 NC)<br />

Typical power loss per conductor (W)<br />

no data<br />

Off-load operating frequency (cycles per hour)<br />

60 for continued operation<br />

Current ratings:<br />

20A @277V 1p 1ph<br />

Tungsten (poles per phase)<br />

20A @480V 2p 1ph<br />

20A @480V 3p 3ph<br />

30A @347V 1p 1ph<br />

Ballast (poles per phase)<br />

30A @600V 2p 1ph<br />

30A @600V 3p 3ph<br />

30A @600V 1p 1ph<br />

General and resistive (poles per phase)<br />

30A @600V 2p 1ph<br />

30A @600V 3p 3ph<br />

Coil ratings:<br />

Nominal voltage<br />

(refer to coil voltage table)<br />

Inrush / sealed power (VA) 248 / 28<br />

Coil voltage tolerance factor 0.85 - 1.1<br />

External/optional auxiliary contact:<br />

Number of NC / NO auxiliary contacts<br />

2NC / 2NO max<br />

Rating<br />

A600, 24VDC, 24VAC<br />

Installation/mounting/dimensions:<br />

Mounting orientation<br />

vertical<br />

Type of mounting: screw / DIN rail<br />

yes / no<br />

Height x Width x Depth (mm) 188 x 106 x 98<br />

Minimum clearance to sides (mm) 12.7<br />

Minimum clearance to earthed parts (mm) 12.7<br />

Connection type / torque:<br />

Main contact terminals<br />

screw / 35 lb in<br />

Coil terminals<br />

screw / 15 lb in<br />

Auxiliary contact terminals<br />

screw / 7-12 lb in<br />

Control module terminals<br />

screw / 5 lb in<br />

Solid and stranded conductors (AWG):<br />

Main contact terminals<br />

1x(14-8), #8 solid or stranded<br />

2x(14-8), #8 stranded only<br />

Coil terminals<br />

2x(18-14)<br />

Auxiliary contact terminals<br />

2x(22-12)<br />

Control module terminals<br />

1x(22-12)<br />

Conductor type for main / control circuits<br />

75°C CU / 60-75°C CU<br />

Short circuit current rating of main circuit:<br />

Short circuit current rating<br />

(see SCCR tables)<br />

Certificates:<br />

cUL<br />

Coil voltages:<br />

24V 60Hz / 20V 50Hz<br />

115-120V 60Hz / 110V 50Hz<br />

200-208V 60Hz<br />

230-240V 60Hz / 220V 50Hz<br />

277V 60Hz / 240V 50Hz<br />

347V 60Hz<br />

460-480V 60Hz / 440V 50Hz<br />

575-600V 60Hz / 550V 50Hz<br />

Short circuit current ratings with fuses:<br />

Max.<br />

Device<br />

Max.<br />

Volt.<br />

Fuse<br />

Rating<br />

(Amps)<br />

SCCR<br />

(kA)<br />

600 RK fuse 60 5<br />

Short circuit current ratings with circuit breakers:<br />

Max.<br />

Volt.<br />

Siemens<br />

Listed<br />

Circuit<br />

Breaker<br />

Max.<br />

Device<br />

Rating<br />

(Amps)<br />

600 NGG3B040L 40 5<br />

480 HEG3B040L 40 5<br />

480 ED63B040L 40 5<br />

480 NGG3B040L 40 5<br />

Conversion module:<br />

Input Volt.<br />

(AC)<br />

Steady State<br />

Current @ Rated<br />

Volts (mA)<br />

Max.<br />

VA<br />

24 80 5<br />

115-120 83 12<br />

200-277 91 30<br />

Conversion module:<br />

Min. pulse duration (3-wire module)<br />

Max. allowable leakage current<br />

EMI<br />

Surge transient peak<br />

Frequency range<br />

250ms<br />

1.8 mA<br />

35 V/m<br />

6 kV<br />

40-70 Hz<br />

SCCR<br />

(kA)<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-91


Lighting and Heating Contactors<br />

Mechanically and Magnetically Held Lighting Contactors, Class CLM<br />

Selection<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

CLM 20 Amp<br />

CLM 100 Amp<br />

Mechanically Latched Lighting<br />

and Heating Contactor<br />

The CLM Lighting Contactors can be<br />

used with metal halide, mercury vapor,<br />

quartz halogen, tungsten and fluorescent<br />

lighting. They provide reliable and<br />

convenient lighting control in numerous<br />

applications, such as industrial plants,<br />

schools, hospitals, office buildings,<br />

shopping centers, airports, stadiums . . .<br />

literally everywhere lighting is required.<br />

The CLMs are listed under UL 508<br />

with no derating when used open or<br />

enclosed. Combination lighting<br />

contactors are listed for UL service<br />

entrance.<br />

UL listed File #E60310<br />

CSA Certified File LR 6535<br />

Type CLM 20 Amp Lighting<br />

Contactor Solid State Control<br />

Modules<br />

The CLM 20 amp lighting contactor<br />

is an electromagnetically operated,<br />

mechanically latched three wire control<br />

contactor. The most commonly used<br />

method of control is a three position<br />

momentary contact switch with a<br />

center-off position. The controlling<br />

device must be able to make the coil<br />

inrush current but need not break it.<br />

The coil current is interrupted by the<br />

control contacts within the CLM<br />

contactor. Power for the control line may<br />

come from a separate source or directly<br />

from the line side of the CLM contactor.<br />

The CLM contactor can also be<br />

controlled by devices such as:<br />

b Break-glass control stations<br />

b Timers having single pole, double<br />

throw contacts<br />

b Photo-electric cells a<br />

b Energy management systems a<br />

b Microprocessors a<br />

b Occupancy sensors a<br />

Control modules make it possible to<br />

use a controlling device that does not<br />

have enough current-carrying capacity<br />

to control the CLM contactor directly.<br />

Control modules are also used when<br />

the control station is to be located at<br />

a distance greater than the allowable<br />

contactor line run.<br />

Another use for control modules occurs<br />

when the controlling device is only<br />

available as a single pole single-throw<br />

contact necessitating a two wire<br />

control line.<br />

Still another application for control<br />

modules is when start-stop three<br />

wire control is needed.<br />

Control modules also can make it<br />

possible to operate the CLM coil from<br />

its own incoming line at one voltage<br />

while providing the control at a<br />

second, perhaps lower voltage.<br />

Two Wire Control Module<br />

(Accessory 47)<br />

The advantages of two wire controls are:<br />

1. Control station can have lower<br />

ampacity rating.<br />

2. Control station can be located an<br />

extended distance from the CLM<br />

contactor.<br />

3. Control module can frequently be<br />

controlled directly from<br />

microprocessor.<br />

4. Control devices can be two wire<br />

single pole, single-throw types.<br />

5. Control voltage may be different than<br />

the CLM coil circuit and at a lower<br />

voltage level.<br />

Note: If the control power to the solid<br />

state control module is lost while the<br />

module is energized the lighting<br />

contactor will open. If the line power<br />

to the lighting contactor is lost while the<br />

contactor is energized the contactor will<br />

not change state with return of line<br />

voltage. Power will be restored to<br />

the load if the control module is still<br />

energized. Control station should<br />

be the maintained type.<br />

Three Wire Control Module<br />

(Accessory 48)<br />

1. The accessory 48 consists of two<br />

relays with contacts appropriately<br />

interconnected which provides for an<br />

interlocking that prevents both relays<br />

from being energized simultaneously.<br />

2. This module has similar characteristics<br />

to the two wire module (Accessory 47)<br />

except there is no change of switch<br />

contact position upon loss of control line<br />

power. Control stations should be the<br />

momentary type.<br />

Stop-Start Control Module<br />

(Accessory 49)<br />

Stop-start three wire maintained control<br />

is an arrangement used mostly when<br />

controlling motors, but can be used in<br />

lighting applications.<br />

Any number of momentary contact<br />

control stations consisting of normally<br />

open start buttons and normally closed<br />

stop buttons can be used. Start buttons<br />

are connected in parallel and stop<br />

buttons in series.<br />

Operation (Magnetic Latch)<br />

A permanent magnet is built into the<br />

contactor structure of the 30A, 60A,<br />

100A, and 200A contactors that will<br />

maintain the contactor in its energized<br />

state indefinitely without using control<br />

power. When energized, a DC current is<br />

applied that produces a magnetic field<br />

that reinforces the polarity of the<br />

permanent magnet, and the contactor<br />

pulls in immediately. The current<br />

to the coil is disconnected by the coil<br />

clearing interlock. In order to drop out<br />

the contactor, it is necessary to apply a<br />

field through the OFF coil in the reverse<br />

direction to the permanent magnet.<br />

This momentarily cancels the magnetic<br />

attraction and the contactor drops out.<br />

Coil and module failures are possible<br />

when used with solid state relays and<br />

PLC outputs. 24-volt systems are ok to<br />

use, but 120 volts and above should be<br />

discouraged. If higher values cannot<br />

be avoided, an interposing relay should<br />

be used.<br />

(Mechanically Latched)<br />

The 300 & 400A lighting and heating<br />

contactors operate using a latching<br />

mechanism.<br />

Closing – When the “close” pushbutton<br />

is operated, the closing coil is energized,<br />

closing the contactor. As the contactor<br />

closes, the latch lever hooks over the<br />

latch pin to mechanically latch the<br />

contactor closed. The coil-clearing<br />

auxiliary contact de-energizes the<br />

closing coil.<br />

Opening – When the “Trip” pushbutton<br />

is operated, the trip solenoid coil is<br />

energized, unhooking the latch lever<br />

from the latch pin, which allows the<br />

contactor to open. As the contactor<br />

opens, the coil-clearing auxiliary contact<br />

de-energizes the trip solenoid coil.<br />

a Operation through control modules.<br />

17-92<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Lighting Control<br />

Mechanically and Magnetically Held Lighting Contactors, Class CLM<br />

Ordering Information<br />

E<br />

Replace *** with a number from the coil table.<br />

E Field modification kits see page 17-102.<br />

E Factory modifications see page 17-114.<br />

E Dimensions see page 17-139 open page 17-153 enclosed.<br />

E Wiring Diagrams see page 17-173.<br />

E Replacement parts see page 17-123.<br />

Revised on 08/31/19<br />

Coil Table<br />

60Hz Voltage<br />

Selection<br />

Number<br />

24 b 024<br />

120 120<br />

208 208<br />

240 240<br />

277 277<br />

480 480<br />

600 600<br />

Open and Non-combination Enclosed Contactors<br />

Open Type <br />

Enclosure<br />

NEMA 1 NEMA 12 NEMA 4/4X Stainless Steel<br />

General Purpose NEMA 3/3R Watertight, Dust-tight,<br />

Industrial Use<br />

Corrosion Resistant,<br />

Max<br />

Weatherproof<br />

304 Stainless Steel<br />

Amp Number<br />

Rating of Poles Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $<br />

2 CLM1B02*** CLM2B02*** CLMSB02***<br />

3 CLM1B03*** CLM2B03*** CLMSB03***<br />

4 CLM1B04*** CLM2B04*** CLMSB04***<br />

20 6 see table CLM1B06*** CLM2B06*** CLMSB06***<br />

8 below CLM1B08*** CLM2B08*** CLMSB08***<br />

10 CLM1B10*** CLM2B10*** CLMSB10***<br />

12 CLM1B12*** CLM2B12*** CLMSB12***<br />

2 CLM0C02*** CLM1C02*** CLM2C02*** CLMSC02***<br />

3 CLM0C03*** CLM1C03*** CLM2C03*** CLMSC03***<br />

4 CLM0C04*** CLM1C04*** CLM2C04*** CLMSC04***<br />

5 CLM0C05*** CLM1C05*** CLM2C05*** CLMSC05***<br />

30 6 CLM0C06*** CLM1C06*** CLM2C06*** — —<br />

8 CLM0C08*** CLM1C08*** CLM2C08*** — —<br />

9 CLM0C09*** CLM1C09*** CLM2C09*** — —<br />

10 CLM0C10*** CLM1C10*** CLM2C10*** — —<br />

12 CLM0C12*** CLM1C12*** CLM2C12*** — —<br />

2 CLM0D02*** CLM1D02*** CLM2D02*** CLMSD02***<br />

3 CLM0D03*** CLM1D03*** CLM2D03*** CLMSD03***<br />

4 CLM0D04*** CLM1D04*** CLM2D04*** CLMSD04***<br />

5 CLM0D05*** CLM1D05*** CLM2D05*** CLMSD05***<br />

60 6 CLM0D06*** CLM1D06*** CLM2D06*** — —<br />

8 CLM0D08*** CLM1D08*** CLM2D08*** — —<br />

9 CLM0D09*** CLM1D09*** CLM2D09*** — —<br />

10 CLM0D10*** CLM1D10*** CLM2D10*** — —<br />

12 CLM0D12*** CLM1D12*** CLM2D12*** — —<br />

2 CLM0E02*** CLM1E02*** CLM2E02*** CLMSE02***<br />

100<br />

3 CLM0E03*** CLM1E03*** CLM2E03*** CLMSE03***<br />

4 CLM0E04*** CLM1E04*** CLM2E04*** CLMSE04***<br />

5 CLM0E05*** CLM1E05*** CLM2E05*** CLMSE05***<br />

2 CLM0F02*** CLM1F02*** CLM2F02*** CLMSF02***<br />

200<br />

3 CLM0F03*** CLM1F03*** CLM2F03*** CLMSF03***<br />

4 CLM0F04*** CLM1F04*** CLM2F04*** CLMSF04***<br />

5 CLM0F05*** CLM1F05*** CLM2F05*** CLMSF05***<br />

300<br />

2 CLM0G02*** CLM1G02*** CLM2G02*** — —<br />

3 CLM0G03*** CLM1G03*** CLM2G03*** — —<br />

400<br />

2 CLM0H02*** CLM1H02*** CLM2H02*** — —<br />

3 CLM0H03*** CLM1H03*** CLM2H03*** — —<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Open 20 Amp Contactors<br />

Max<br />

110–120V Coil 50/60Hz 208–240V Coil 50/60Hz 265–277V Coil 50/60Hz<br />

Amp Number<br />

Rating of Poles a Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $<br />

2 CLM22031 CLM22061 CLM22071<br />

3 CLM32031 CLM32061 CLM32071<br />

4 CLM42031 CLM42061 CLM42071<br />

20 6 CLM62031 CLM62061 CLM62071<br />

8 CLM82031 CLM82061 CLM82071<br />

10 CLM102031 CLM102061 CLM102071<br />

12 CLM122031 CLM122061 CLM122071<br />

a Contactors with 2–6-poles will be assembled with<br />

all poles located in the top portion of the contactor.<br />

Contactors with 8–12-poles will be assembled with<br />

6-poles in the top portion and the remaining poles in<br />

the bottom portion of the contactor.<br />

b 24 volt coils are not available on 20, 300 and 400 amp<br />

contactor sizes. For 24 volt control of 20 amp contactor<br />

select solid state control module.<br />

CLM 30 & 60A 6-12-pole can be field assembled.<br />

Order mounting kit 49MCMPMA and the appropriate<br />

number of 2-5 pole contactors.<br />

480 or 600 volt coils are not available on 20 amp<br />

contactors.<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-93


Lighting Control<br />

Combination Mechanically and Magnetically Held Lighting Contactors, Class CM<br />

Ordering Information<br />

E<br />

Replace *** with a number from the coil table.<br />

E Field modification kits see page 17-102.<br />

E Factory modifications see page 17-114.<br />

E Dimensions see page 17-153.<br />

E Wiring Diagrams see page 17-173.<br />

E Replacement parts see page 17-123.<br />

Coil Table<br />

60Hz Voltage<br />

Revised on 08/31/18<br />

Selection<br />

Number<br />

24 a 024<br />

120 120<br />

208 208<br />

240 240<br />

277 277<br />

480 480<br />

600 600<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Combination Lighting Contactors<br />

Enclosure<br />

NEMA 1 NEMA 12, NEMA 3/3R NEMA 4/4X Stainless Steel<br />

General Purpose NEMA 4 Painted (thru 100 amps) Watertight, Dust-tight,<br />

Industrial Use<br />

Corrosion Resistant,<br />

Contactor Number Disc Disc Amp/ Circuit Weatherproof, Watertight, Dust-tight 304 Stainless Steel<br />

Disconnect Amp of NO Amp Fuse Clip Breaker<br />

Type Rating Poles Rating Rating Rating Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $<br />

20 3 30A — — CMNB14*** CMNB24*** CMNBS4***<br />

30 3 30A — — CMNC14*** CMNC24*** CMNCS4***<br />

Non-Fusible<br />

60 3 60A — — CMND15*** CMND25*** CMNDS5***<br />

100 3 100A — — CMNE16*** CMNE26*** CMNES6***<br />

200 3 200A — — CMNF17*** CMNF27*** CMNFS7***<br />

300 3 400A — — CMNG18*** CMNG28*** CMNGS8***<br />

20<br />

3 — 30A/250V — CMFB10*** CMFB20*** CMFBS0***<br />

3 — 30A/600V — CMFB11*** CMFB21*** CMFBS1***<br />

30<br />

3 — 30A/250V — CMFC10*** CMFC20*** CMFCS0***<br />

3 — 30A/600V — CMFC11*** CMFC21*** CMFCS1***<br />

Fusible<br />

60<br />

3 — 60A/250V — CMFD12*** CMFD22*** CMFDS2***<br />

3 — 60A/600V — CMFD13*** CMFD23*** CMFDS3***<br />

100<br />

3 — 100A/250V — CMFE14*** CMFE24*** CMFES4***<br />

3 — 100A/600V — CMFE15*** CMFE25*** CMFES5***<br />

200<br />

3 — 200A/250V — CMFF16*** CMFF26*** CMFFS6***<br />

3 — 200A/600V — CMFF17*** CMFF27*** CMFFS7***<br />

300<br />

3 — 400A/250V — CMFG18*** CMFG28*** CMFGS8***<br />

3 — 400A/600V — CMFG19*** CMFG29*** CMFGS9***<br />

20 3 — — 20A CMBB14*** CMBB24*** CMBBS4***<br />

Circuit 30 3 — — 30A CMBC15*** CMBC25*** CMBCS5***<br />

Breaker 60 3 — — 60A CMBD18*** CMBD28*** CMBDS8***<br />

100 3 — — 100A CMBE18*** CMBE28*** CMBES8***<br />

200 3 — — 200A CMBF10*** CMBF20*** CMBFS0***<br />

300 3 — — 300A CMBG11*** CMBG21*** CMBGS1***<br />

Lighting & Heating Contactor Ratings CLM<br />

Maximum AC/DC Voltage and<br />

Amp Ratings<br />

Poles to Load<br />

Load Amperes 2 for 1-Phase<br />

Type Continuous 1 for 1-Phase 3 for 3-Phase<br />

Tungsten 20 250V AC 250V AC<br />

Ballast 20 347V AC 600V AC<br />

General 30 347V AC 600V AC<br />

General 20 125V DC 250V DC<br />

Inrush Current Over Fuse Size (amps RMS)<br />

at AC Control Voltage 20A CLM<br />

Amps 120V 240V 277V 347V 480V<br />

Inrush 5.0 2.5 2.2 1.8 1.3<br />

Fuse 2.0 1.0 1.0 0.75 0.5<br />

Contactor Ratings<br />

Load Amperes Max Volts Max Volts<br />

Type Continuous Line to Line Line to Neutral<br />

Tungsten 30-400 480 277<br />

Ballast 30-400 600 346<br />

Heating 30-400 600 346<br />

AC Coil Data<br />

Contactor<br />

Amperes No. Poles Inrush VA Dropout VA<br />

20 2-12 625 6<br />

30 2-5 410 40<br />

60 2-3 410 40<br />

60 4-5 600 40<br />

100/200 2-3 900 200<br />

100/200 4-5 1300 130<br />

300/400 2-3 1600 550<br />

a 24 volt coils are not available on 20 and 300 amp contactors.<br />

Use solid state control module on 20 amp size.<br />

600 volt coils are not available on 20 amp<br />

contactors.<br />

17-94<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Industrial Control Power Transformers<br />

Class MT<br />

Revised on 03/31/30<br />

General<br />

Features<br />

b Enclosed coils (50-5000VA);<br />

Completely encloses the transformer<br />

coils against moisture, dust, dirt and<br />

industrial contaminants for maximum<br />

protection in hostile and industrial environments.<br />

b Fuse clips (most models). Factory<br />

mounted for integral fusing on the<br />

secondary side to save panel space,<br />

save wiring time and save the cost<br />

of buying an add-on fuse block or kit<br />

b Integrally finger safe terminals.<br />

Between terminals and transformer,<br />

protect against electrical creepage.<br />

Up to 30% greater terminal contact<br />

area permits low-loss connections.<br />

Extra-deep barriers reduce the chance<br />

of shorts from frayed leads or careless<br />

wiring<br />

b Terminals. Molded into the<br />

transformer, are difficult to break<br />

during wiring. A full quarter-inch of<br />

thread on the 8-32 terminal screws<br />

prevents stripping and pullout<br />

b Jumpers supplied. Two jumper links<br />

are standard with all transformers<br />

which can be wired for dual primary<br />

voltages<br />

Operation<br />

Industrial control circuits and motor<br />

control loads typically require more<br />

current when they are initially energized<br />

than under normal operating conditions.<br />

This period of high current demand,<br />

referred to as inrush, may be as great<br />

as ten times the current required under<br />

steady state (normal) operating<br />

conditions, and can last up to 40<br />

milliseconds. A transformer in a circuit<br />

subject to inrush will typically attempt<br />

to provide the load with the required<br />

current during the inrush period.<br />

However, it will be at<br />

the expense of the secondary voltage<br />

stability by allowing the voltage to<br />

the load to decrease as the current<br />

increases. This period of secondary<br />

voltage instability, resulting from<br />

increased current, can be of such<br />

magnitude that the transformer is<br />

unable to supply sufficient voltage to<br />

energize the load. The transformer<br />

must therefore be designed and<br />

constructed to accommodate the high<br />

inrush current, while maintaining<br />

secondary voltage stability. According<br />

to NEMA standards, the secondary<br />

voltage would typically be<br />

at 85% of the rated voltage.<br />

Industrial Control Power Transformers<br />

are specifically designed and built to<br />

provide adequate voltage to the load<br />

while accommodating the high current<br />

levels present at inrush. These<br />

transformers deliver excellent<br />

secondary voltage regulation and meet<br />

or exceed the standards established<br />

by NEMA, ANSI, UL and cUL. Their<br />

rugged construction and excellent<br />

electrical characteristics ensure reliable<br />

operation of electromagnetic devices<br />

and trouble-free performance.<br />

Specifications<br />

b Laminations are built with silicon<br />

steel to minimize core losses and<br />

to increase optimum performance and<br />

efficiency<br />

b Copper magnet wire of the highest<br />

quality assures efficient operation<br />

b Factory mounted type “K” fuse<br />

clips are standard on all secondary<br />

transformers where possible<br />

b Two jumper links are standard with<br />

all transformers which can be wired<br />

for dual primary voltages<br />

b cUL Listed and CSA certified<br />

b 50/60 Hz rated<br />

b Insulation materials are of the<br />

highest rating available for the<br />

temperature class<br />

b Mounting plate is heavy gauge steel<br />

to add strength to core construction<br />

and provide stable mounting. Slotted<br />

mounting feet permit easy installation<br />

b Attractive black finish; easy-to-read<br />

nameplate with complete rating data<br />

and wiring diagram<br />

b Class 130°C (226°F) insulation<br />

system. 80°C (176°F) temperature<br />

rise. (50-750VA typical)<br />

b Class 180°C (356°F) insulation<br />

system. 120°C (248°F) temperature<br />

rise. (1000–5000VA typical)<br />

b Optional field mounted 2-pole<br />

primary Class CC fuse block is<br />

available<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-95


Industrial Control Power Transformers<br />

Class MTG<br />

General<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Features<br />

b Class MTG Industrial Control Transformers are 100%<br />

certified for all domestic and International Applications<br />

b The MTG line has full compliance with IEC Safety<br />

standards EN 61 558<br />

b CE Mark in accordance with requirements for EN 61 558<br />

b Meets IP-20 specifications per IEC 529 for finger-safe<br />

protection because all of our CPTs come standard with<br />

touchsafe terminals, both primary and secondary sides.<br />

There is no need to buy any terminal cover accessories.<br />

b UL Listed<br />

b Exceeds applicable requirements for control transformers as<br />

determined by NEMA and ANSI<br />

b Insulation requirements is twice that of UL5085<br />

b Available in 50 to 750 VA sizes, in all standard voltage<br />

combinations<br />

b Class 130°C (226°F) insulation system. 80°C (176°F)<br />

temperature rise. (50-750VA typical)<br />

b Class 180°C (356°F) insulation system. 120°C (248°F)<br />

temperature rise. (1000–5000VA typical)<br />

b Primary and secondary fusing capability available as field<br />

installed kits for domestic or international fusing<br />

b Integrally-molded terminals and barriers between terminals<br />

make breakage virtually impossible during wiring. The MTG<br />

transformer construction is the same as our high quality<br />

Class MT transformers<br />

Optional Field Installed Fuse Clip Kits For Panel<br />

Mounting<br />

b 2-Pole primary Class CC fuse block<br />

b 1-Pole secondary midget fuse block for 13 ⁄32 u 1 1 ⁄2 fuses<br />

b 2-Pole primary international type fuse blocks<br />

b 1-Pole secondary international type fuse blocks<br />

Touch safe terminals are standard on all CPTs<br />

The Touch-Safe terminals are designed to comply with IEC<br />

742 and IP 20 requirements. The international fuse block kits<br />

have inherent touch safe terminals and fuse clips.<br />

Siemens Meets International Standards<br />

CSA (Canadian Standards Association) was utilized as a<br />

Competent Body in reviewing, interpreting and properly<br />

complying with the requirements of IEC-742 to place a CE<br />

mark on its MTG Series product. As a National Certification<br />

Body, CSA also has the proper documentation and reports<br />

on file for MTG Series to utilize the CB Scheme ensuring<br />

acceptance throughout the world.<br />

The standard Siemens MTG product is available with terminal<br />

covers which meets the requirements of IEC-529, IP20<br />

degree of protection and meets the applicable requirements<br />

for covers per IEC-742.<br />

IEC-742<br />

The requirements for industrial control circuit transformers<br />

to be used in the European Common Market are identified<br />

by the International Electrotechnical Commission (IEC) and<br />

specified under IEC-742, Non-Short Circuit Proof Isolating<br />

Transformers, under the Low Voltage Directive 73/23/EEC.<br />

Manufacturers of control transformers indicate compliance<br />

with these requirements by placing a CE mark on the<br />

product.<br />

b Winding to winding insulation requirements may be twice<br />

that for IEC-742 compared to UL506<br />

b The electrical clearances between current carrying parts<br />

are one-third greater to comply with IEC-742 requirements<br />

for units up to 250VA with voltages up to 440 volts ac<br />

b Transformers manufactured to IEC-742 requirements<br />

will have a minimum of 10% higher overload capacity<br />

than those manufactured only to UL506 requirements<br />

While no requirement exists in IEC-742 for the electrical<br />

connections to be either finger safe or touch proof, the<br />

specification does state that IF a transformer is supplied<br />

with a cover to prevent incidental contact with current<br />

carrying parts, that cover must utilize two separate methods<br />

or places of securing it to the component, with neither being<br />

dependent upon the other. Additionally, one of these methods<br />

MUST require a tool to remove it.<br />

IEC-529<br />

The requirements for finger-safe or touch-proof electrical<br />

connections are identified by the International Electrotechnical<br />

Commission (IEC) under specification 529, Classification of<br />

Degrees of Protection Provided by Enclosures. These various<br />

degrees of protection are identified and differentiated by IP<br />

ratings.<br />

The IP specification which most closely approximates<br />

protection to a human finger is IP20. This IP rating would<br />

be the most common degree of touch-proof connection<br />

for electrical components such as transformers.<br />

EN 61 558<br />

The requirements for industrial control transformers to be<br />

used in the European Common Market are identified<br />

by the IEC and specified in EN 61 558, Safety of Power<br />

Control Transformers, under Low Voltage Directive 73/23/EEC.<br />

CE mark on the product indicates compliance.<br />

17-96<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Industrial Control Power Transformers<br />

Class MT, MTG<br />

General<br />

Transformer Selection<br />

Process<br />

Selecting a transformer for industrial<br />

control circuit applications requires<br />

knowledge of the following terms:<br />

Inrush VA is the product of load voltage<br />

(V) multiplied by the current (A) that<br />

is required during circuit start-up. It<br />

is calculated by adding the inrush VA<br />

requirements of all devices (contactors,<br />

timers, relays, pilot lights, solenoids,<br />

etc.), which will be energized<br />

together. Inrush VA requirements are<br />

best obtained from the component<br />

manufacturer.<br />

Sealed VA is the product of load<br />

voltage (V) multiplied by the current (A)<br />

that is required to operate the circuit<br />

after initial start-up or under normal<br />

operating conditions. It is calculated by<br />

adding the sealed VA requirements of<br />

all electrical components of the circuit<br />

that will be energized at any given<br />

time. Sealed VA requirements are<br />

best obtained from the component<br />

manufacturer. Sealed VA is also<br />

referred to as steady state VA.<br />

Primary Voltage is the voltage available<br />

from the electrical distribution<br />

system and its operational frequency,<br />

which is connected to the transformer<br />

supply voltage terminals.<br />

Secondary Voltage is the voltage<br />

required for load operation which is connected<br />

to the transformer load<br />

voltage terminals.<br />

Once the circuit variables have been determined, transformer selection is a simple<br />

5-step process as follows:<br />

1. Determine the Application Inrush VA by using the following industry accepted formula:<br />

——————————–<br />

Application Inrush VA = √(Inrush VA) 2 r (Sealed VA) 2<br />

2. Refer to the Regulation Data Chart. If the primary voltage is basically stable and<br />

does not vary by more than 5% from nominal, the 90% secondary voltage column<br />

should be used. If the primary voltage varies between 5% and 10% of nominal,<br />

the 95% secondary voltage column should be used.<br />

3. After determining the proper secondary voltage column, read down until a value<br />

equal to or greater than the Application Inrush VA is found. In no case should a<br />

figure less than the Application Inrush VA be used.<br />

4. Read left to the Transformer VA Rating column to determine the proper<br />

transformer for this application. As a final check, make sure that the Transformer<br />

VA Rating is equal to or greater than the total sealed requirements. If not, select<br />

a transformer with a VA rating equal to or greater than the total sealed VA.<br />

5. Refer to the following pages to determine the proper catalog number based<br />

on the transformer VA, and primary and secondary voltage requirements.<br />

Regulation Data Chart<br />

Inrush VA At 20% Power Factor<br />

NEMA/IEC NEMA/IEC NEMA/IEC<br />

Transformer 95% Sec 90% Sec 85% Sec<br />

VA Ratings Voltage Voltage Voltage<br />

25 100/––– 130/––– 150/–––<br />

50 170/190 200/220 240/270<br />

75 310/350 410/460 540/600<br />

100 370/410 540/600 730/810<br />

150 780/860 930/1030 1150/1270<br />

200 810/900 1150/1270 1450/1600<br />

250 1400/1540 1900/2090 2300/2530<br />

300 1900/2090 2700/2970 3850/4240<br />

350 3100/3410 3650/4020 4800/5280<br />

500 4000/4400 5300/5830 7000/7700<br />

750 8300/9130 11000/12100 14000/15400<br />

1000 a 15000/––– 21000/––– 27000/–––<br />

1000 b 9000/––– 13000/––– 18500/–––<br />

1500 10500/––– 15000/––– 205000/–––<br />

2000 17000/––– 25500/––– 34000/–––<br />

3000 24000/––– 36000/––– 47500/–––<br />

5000 55000/––– 92500/––– 115000/–––<br />

To comply with NEMA standards, which require all magnetic devices to operate successfully at 85% of rated voltage, the<br />

90% secondary voltage column is most often used in selecting a transformer.<br />

a For units with Class 105°C insulation systems.<br />

b For units with Class 180°C insulation systems.<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Fuse Clip Kit KCCFPX2R<br />

Primary Fuse Kit<br />

In addition to factory installed secondary<br />

fusing, Siemens offers a primary<br />

fuse kit for class MT transformers size<br />

50–750 VA for field installation. The<br />

primary fuse kit includes a 2-pole Class<br />

cc fuse block, instructions and all<br />

associated mounting and wiring<br />

hardware. Additionally, this fuse kit<br />

will fit most competitors’ units. To<br />

order this kit, use catalog number<br />

KCCFPX2R. The primary fuse kit,<br />

when installed, will add a maximum of<br />

0.69 in. (18 mm) to the transformer “A”<br />

dimension and 1.94 in. (49 mm) to the<br />

“C” dimension.<br />

Primary Fuse Kit Installation—Class MT Transformer with Primary Fuse Kit, KCCFPX2R<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-97


Industrial Control Power Transformers<br />

Domestic, Class MT<br />

Revised on 03/31/20<br />

Selection<br />

Ordering Information<br />

E Use the Voltage Table to determine the<br />

primary and secondary voltage required.<br />

E Field Modifications see page 17-110.<br />

E Dimension and wiring diagrams are<br />

available in CAD and PDF format on<br />

SIOS.<br />

E All MT and MTG CPTs come standard<br />

with touch safe terminals.<br />

Voltage Table<br />

Primary Volts 50/60 Hz Secondary Volts Letter<br />

240 X 480, 230 X 460, 220 X 440 120/115/110 A<br />

240 X 480 24 B<br />

120 X 240 24 C<br />

115 X 230 24 D<br />

550/575/600 110/115/120 E<br />

208/277 120 F<br />

208/230/460 115 G<br />

230/460/575 95/115 H<br />

380/400/415 110 X 220 I<br />

208/230/460, 200/220/440,240/480 24 X 115, 23 X 110, 25 X 120 J<br />

240/416/480/600, 230/400/460/575, 99/120/130, 95/115/125,<br />

220/380/440/550, 208/500 91/110/120, 85/100/110<br />

L<br />

240 X 480 120 X 240 M<br />

Voltage Letter Voltage Letter Voltage Letter Voltage Letter Voltage Letter Voltage Letter<br />

VA<br />

A B C D E F<br />

Rating Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

50 MT0050A MT0050B MT0050C MT0050D MT0050E MT0050F<br />

75 MT0075A MT0075B MT0075C MT0075D MT0075E MT0075F<br />

100 MT0100A MT0100B MT0100C MT0100D MT0100E MT0100F<br />

150 MT0150A MT0150B MT0150C MT0150D MT0150E MT0150F<br />

200 MT0200A MT0200B MT0200C MT0200D MT0200E MT0200F<br />

250 MT0250A MT0250B MT0250C MT0250D MT0250E MT0250F<br />

300 MT0300A MT0300B MT0300C MT0300D MT0300E MT0300F<br />

350 MT0350A MT0350B MT0350C MT0350D MT0350E MT0350F<br />

500 MT0500A MT0500B MT0500C MT0500D MT0500E MT0500F<br />

750 MT0750A MT0750B — — — — MT0750E MT0750F<br />

1000 MT1000A — — — — — — MT1000E — —<br />

1500 MT1500A — — — — — — — — — —<br />

2000 MT2000A — — — — — — — — — —<br />

3000 MT3000A — — — — — — — — — —<br />

5000 MT5000A — — — — — — — — — —<br />

Voltage Letter Voltage Letter Voltage Letter Voltage Letter Voltage Letter Voltage Letter<br />

VA<br />

G H I J L M<br />

Rating Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $<br />

50 MT0050G MT0050H MT0050I MT0050J MT0050L MT0050M<br />

75 MT0075G MT0075H MT0075I MT0075J — — MT0075M<br />

100 MT0100G MT0100H MT0100I MT0100J MT0100L MT0100M<br />

150 MT0150G MT0150H MT0150I MT0150J MT0150L MT0150M<br />

200 MT0200G MT0200H MT0200I MT0200J — — MT0200M<br />

250 MT0250G MT0250H MT0250I MT0250J MT0250L MT0250M<br />

300 MT0300G MT0300H MT0300I MT0300J — — MT0300M<br />

350 MT0350G MT0350H — MT0350I MT0350J MT0350L MT0350M<br />

500 MT0500G MT0500H MT0500I MT0500J MT0500L MT0500M<br />

750 MT0750G MT0750H MT0750I — — MT0750L MT0750M<br />

1000 MT1000G MT1000H MT1000I — — — — MT1000M<br />

1500 MT1500G MT1500H MT1500I — — — — MT1500M —<br />

2000 MT2000G MT2000H MT2000I — — — — MT2000M —<br />

3000 MT3000G MT3000H MT3000I — — — — MT3000M —<br />

5000 MT5000G MT5000H — — — — — — MT5000M —<br />

17-98<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Industrial Control Power Transformers<br />

International, Class MTG<br />

Revised on 03/31/30<br />

Selection<br />

Ordering Information<br />

E Use the Voltage Table to determine<br />

the primary and secondary voltage<br />

required.<br />

E Field Modifications see page 17-110.<br />

E Dimension and wiring diagrams are<br />

available in CAD and PDF format on<br />

SIOS.<br />

E All MT and MTG CPTs come standard<br />

with touch safe terminals.<br />

Voltage Table<br />

Primary Volts 50/60 Hz Secondary Volts Letter<br />

240 X 480, 230 X 460, 220 X 440 120/115/110 A<br />

240 X 480 24 B<br />

120 X 240 24 C<br />

550/575/600 110/115/120 E<br />

380/400/415 110 X 220 I<br />

208/230/460, 200/220/440, 240/480 24 X 115, 23 X 110, 25 X 120 J<br />

380 24 P<br />

Voltage Letter Voltage Letter Voltage Letter Voltage Letter Voltage Letter Voltage Letter Voltage Letter<br />

VA<br />

A B C E I J P<br />

Rating Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $<br />

50 MTG0050A MTG0050B MTG0050C MTG0050E MTG0050I MTG0050J MTG0050P<br />

75 MTG0075A MTG0075B MTG0075C MTG0075E MTG0075I MTG0075J MTG0075P<br />

100 MTG0100A MTG0100B MTG0100C MTG0100E MTG0100I MTG0100J MTG0100P<br />

150 MTG0150A MTG0150B MTG0150C MTG0150E MTG0150I MTG0150J MTG0150P<br />

200 MTG0200A MTG0200B MTG0200C MTG0200E MTG0200I MTG0200J MTG0200P<br />

250 MTG0250A MTG0250B MTG0250C MTG0250E MTG0250I MTG0250J MTG0250P<br />

300 MTG0300A MTG0300B MTG0300C MTG0300E MTG0300I MTG0300J MTG0300P<br />

350 MTG0350A MTG0350B MTG0350C MTG0350E MTG0350I MTG0350J MTG0350P<br />

500 MTG0500A MTG0500B MTG0500C MTG0500E MTG0500I MTG0500J MTG0500P<br />

750 MTG0750A MTG0750B MTG0750C MTG0750E MTG0750I MTG0750J MTG0750P<br />

1000 MTG1000A MTG1000B MTG1000C — MTG1000E — MTG1000I — MTG1000J — —<br />

1500 MTG1500A — — — — MTG1500E — MTG1500I — — — — —<br />

2000 MTG2000A — — — — MTG2000E — MTG2000I — — — — —<br />

3000 MTG3000A — — — — MTG3000E — MTG3000I — — — — —<br />

5000 MTG5000A — — — — MTG5000E — MTG5000I — — — — —<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-99


Field Modification Kits<br />

Class SMF, MMS, MRS<br />

Accessories—Class SMF<br />

Catalog List<br />

Description Number Price $<br />

Handle Guard Kit with Padlock Provision<br />

SMFFL1<br />

Emergency Off Actuator<br />

SMFPB1<br />

Additional Key for Key Operated Devices<br />

SMFFK1<br />

Pilot Light Kits—Class MMS, MRS a<br />

Red<br />

Green<br />

Voltage<br />

Pilot Light<br />

Pilot Light<br />

Device Rating Catalog Number List Price $ Catalog Number List Price $<br />

Class SMF 115–277V AC SMFPL10 SMFPL10G<br />

Selection<br />

Accessories—Class MMS, MRS<br />

List<br />

Description Catalog Number Price $<br />

Handle Guard Kit with Padlock Provision<br />

SMFFL1<br />

Emergency Off Actuator<br />

SMFPB1<br />

Additional Key for Key Operated Devices<br />

SMFFK1<br />

Pilot Light Kits—Class MMS, MRS a<br />

Red<br />

Green<br />

Voltage<br />

Pilot Light<br />

Pilot Light<br />

Device Rating Catalog Number List Price $ Catalog Number List Price $<br />

110–120V AC SMFPL11 SMFPL11G<br />

Class MMS 208–277V AC SMFPL12 SMFPL12G<br />

440–600V AC SMFPL13 SMFPL13G<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Enclosures—Class SMF<br />

Catalog List<br />

Enclosure Type For Use With SMF Number Price $<br />

Standard Size<br />

NEMA 1<br />

General Purpose<br />

Oversized<br />

NEMA Type 1<br />

General Purpose<br />

NEMA 3R, 4, 12<br />

Watertight<br />

Dust-tight<br />

FO1, FO1P, FO2, FO2P, FO3,<br />

FO3P, FO4, FO4P<br />

FO1, FO1P, FO2, FO2P, FO3,<br />

FO3P, FO4, FO4P<br />

FO1, FO1P, FO2, FO2P, FO3,<br />

FO3P, FO4, FO4P<br />

SMFFE2<br />

SMFFE1<br />

SMF40BC2<br />

Nameplates—Class SMF<br />

Without<br />

With<br />

Pilot Light<br />

Pilot Light<br />

Nameplate Catalog List Catalog List<br />

For Use On Marking Number Price $ Number Price $<br />

Standard<br />

commercial switch box<br />

cover including None SMFFN2 — —<br />

stainless steel plates<br />

Stainless Steel Plate None SMFFSN3 SMFFSN4<br />

NEMA 1 None SMFFN30 SMFFN40<br />

surface mounted enclosure High SMFFN31 SMFFN41<br />

or gray flush plate Low SMFFN32 SMFFN42<br />

Enclosures—Class MMS<br />

Catalog List<br />

Enclosure Type For Use With MMS Number Price $<br />

Standard Size<br />

KO1, KO1P, KO1B, KO2,<br />

NEMA 1 KO2A, KO2B, KO3, KO3A, MMSKE3<br />

General Purpose<br />

KO3B, KO4, KO4A, KO4B<br />

Oversized<br />

KO1, KO2B, KO2C, KO3,<br />

NEMA Type 1 KO3A, KO3B, KO4, KO4B, SMFKE1<br />

General Purpose<br />

KO4C, KO2<br />

Jumbo<br />

KO1, KO2B, KO2C, KO3,<br />

NEMA Type 1 KO3A, KO3B, KO4, KO4B, SMFKE2<br />

General Purpose<br />

KO4C, KO2<br />

NEMA 3R, 4, 12<br />

KO1, KO2B, KO2C, KO3,<br />

Watertight KO3A, KO3B, KO4, KO4B, SMF40BC2<br />

Dust-tight<br />

KO4C<br />

Nameplates —Class MMS<br />

Without<br />

With<br />

Pilot Light<br />

Pilot Light<br />

Nameplate Catalog List Catalog List<br />

For Use On Marking Number Price $ Number Price $<br />

Standard<br />

commercial switch box<br />

cover including None SMFFN1 — —<br />

stainless steel plates<br />

NEMA 1 None SMFFN10 SMFFN20<br />

surface mounted High SMFFN11 SMFFN21<br />

enclosure or Low SMFFN12 SMFFN22<br />

gray flush plate Forward SMFFN13 — —<br />

Reverse SMFFN14 SMFFN24<br />

Replacement Parts—Class SMF, MMS<br />

List<br />

Description Catalog Number Price $<br />

Replacement Toggle Kits:Type FW and KW (NEMA 4 Metallic Enclosure)<br />

SMFHW1<br />

a Pilot lights can be field installed on standard NEMA 1<br />

general purpose surface mount enclosures, and<br />

NEMA 3R, 4 and 12 enclosures only.<br />

For flush mounting units a complete switch unit with<br />

pilot light must be ordered.<br />

17-100<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Field Modification Kits<br />

Class 11 - 3RV<br />

Selection<br />

Description Type Catalog Number List Price $<br />

Auxiliary Contact Blocks<br />

3RV2901-1D<br />

3RV2901-1A<br />

3RV2922-1CP0<br />

Plug in contact block<br />

1 block per 3RV<br />

mountable at the front<br />

Side mount auxiliary contact with<br />

screw connection<br />

1 side mount auxiliary<br />

contact per 3RV mountable<br />

on the left-hand side<br />

Signaling Contact Block<br />

Signaling contact<br />

1 signaling contact per 3RV<br />

mountable on the left-hand<br />

side. Can also be fitted<br />

together with side mount<br />

auxiliary contact.<br />

Auxiliary Releases<br />

Undervoltage release<br />

1 undervoltage release<br />

per 3RV mountable on the<br />

right-hand side.<br />

Cannot be fitted together<br />

with shunt trip.<br />

Undervoltage release<br />

with early make contacts (2NO)<br />

1 undervoltage release<br />

per 3RV mountable at<br />

the right-hand side.<br />

Cannot be fitted together<br />

with shunt trip.<br />

Shunt trip<br />

1 shunt trip per 3RV<br />

mountable at the righthand<br />

side. Cannot be<br />

fitted together with<br />

undervoltage release.<br />

Pilot Lights<br />

3RV2901-1D<br />

1 SPDT contact, NO/NC<br />

1 SPDT contact NO/NC electronic contact d 3RV2901-1G<br />

1 NO r 1 NC<br />

3RV2901-1E<br />

1 NO r 1 NC 3RV2901-1A<br />

2 NO 3RV2901-1B<br />

2 NC 3RV2901-1C<br />

2 NO r 2 NC 3RV2901-1J<br />

1NO + 1NC for any trip<br />

+<br />

1NO + 1NC for short<br />

circuit trip only.<br />

3RV2921-1M<br />

AC 50Hz<br />

AC 60Hz<br />

— 120V 3RV2902-1AF0<br />

230V 208V 3RV2902-1AM1<br />

415V 240V 3RV2902-1AP0<br />

480V<br />

3RV2902-1AV1<br />

AC 50Hz<br />

AC 60Hz<br />

230V 240V 3RV2922-1CP0<br />

415V 480V 3RV2922-1CV1<br />

AC 50Hz/60Hz a<br />

DC b<br />

20–24V 20–70V 3RV2902-1DB0<br />

90–110V 70–190V 3RV2902-1DF0<br />

200–240V 190–330V 3RV2902-1DP0<br />

350–415V 330–500V 3RV2902-1DV0<br />

AC 50Hz/60Hz<br />

24V<br />

49SBLBJ c<br />

For NEMA 1 enclosure only. Kit<br />

120V<br />

49SBLBF c<br />

includes Red, Green, and<br />

240V<br />

49SBLBG c<br />

Amber lenses<br />

480V<br />

49SBLBH c<br />

3RV2902-1DP0 600V 49SBLBE c<br />

3RV2928-1H<br />

3RV2901-0H<br />

Lug Kit<br />

Required for Type E Manual<br />

Combination Starter<br />

Mounting<br />

Push-in Mounting Hole Kit<br />

For screw panel mounting<br />

of the 3RV<br />

Sealing device<br />

Adjustment Dial covers<br />

Front mount auxiliary cover<br />

Door Operators<br />

Thru-the-door operators<br />

Rotary operating mechanism, rated<br />

NEMA 12, lockable with up to<br />

3 padlocks in the OFF position.<br />

Includes extension shift and<br />

connecting element for the 3RV.<br />

For 3RV with amp range:<br />

0.11-22A up to 480V Max. 0.11-12.5A up to<br />

575V Max<br />

Four mounting holes required for each 3RV.<br />

For sealing the FLA<br />

adjustment dial<br />

(Kit includes 10 covers)<br />

For sealing the front mount<br />

auxiliary opening. (Kit includes 10 covers)<br />

With Black Handle<br />

3RV2928-1H<br />

3RV2928-0B<br />

3RV2908-0P<br />

3RV2901-0H<br />

130 mm depth 3RV2926-0B<br />

330 mm depth with<br />

supporting bracket<br />

3RV2926-0K<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

a 100% on time.<br />

b 5 sec. max. on time.<br />

c Product Category: PILO.<br />

d Compatible for use in dusty atmospheres. Contacts<br />

rated for 1-300mA @ 3-60V.<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-101


Field Modification Kits<br />

Pilot Devices<br />

Revised on 03/31/20<br />

Selection<br />

Push Buttons and Enclosure Controller Size or Catalog List<br />

Selector Switches Class Type (Lighting Rating) Type Number Price $<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

49SDPB5<br />

49SDSB1<br />

49SAP05<br />

49SAS01<br />

Start, Stop Push Buttons<br />

49SAPB5<br />

Open 00-4 Hand-Off-Auto Selector Switch 49SASB1<br />

Off-On Selector Switch<br />

49SASB4<br />

Start, Stop Push Buttons<br />

49SDPB5<br />

00-4 or (20–100A) Hand-Off-Auto Selector Switch 49SDSBJ<br />

Off-On Selector Switch<br />

49SDSB4<br />

14, 40, LC, LEN, CLMa 1 Start, Stop Push Buttons 49SAP05<br />

Hand-Off-Auto Selector Switch<br />

49SAS01<br />

5-8 or (200–400A)<br />

Keyed Hand-Off-Auto (key removable in all positions) 49SAS09<br />

Off-On Selector Switch<br />

49SAS04<br />

Start, Stop Push Buttons<br />

49SAP05<br />

12, 4/4X 00-8 or (20–400A)<br />

Hand-Off-Auto Selector Switch<br />

49SAS01<br />

Keyed Hand-Off-Auto (key removable in all positions) 49SAS09<br />

Off-On Selector Switch<br />

49SAS04<br />

Open 00-4 Forward-Off-Reverse Selector Switch 49SASB2<br />

00-4 Forward-Off-Reverse Selector Switch 49SDSBJ<br />

22, 43<br />

1<br />

Forward, Reverse, Stop Push Buttons<br />

49SAP02<br />

5-8<br />

Forward-Off-Reverse Selector Switch<br />

49SAS02<br />

12, 4/4X 0-8<br />

Forward, Reverse, Stop Push Buttons<br />

49SAP02<br />

Forward-Off-Reverse Selector Switch<br />

49SAS02<br />

Open 0-4 High-Off-Low Selector Switch 49SASB3<br />

0-1 3 ⁄4 High-Off-Low Selector Switch 49SDSBJ<br />

30 (2S1W)<br />

1<br />

High, Low, Stop Push Buttons<br />

49SAP03<br />

2-4<br />

High-Off-Low Selector Switch<br />

49SAS03<br />

12, 4/4X 0-4<br />

High, Low, Stop Push Buttons<br />

49SAP03<br />

High-Off-Low Selector Switch<br />

49SAS03<br />

Open 0-4 High-Off-Low Selector Switch 49SASB3<br />

1 0-4 High-Off-Low Selector Switch 49SDSBJ<br />

30 (2S2W)<br />

High, Low, Stop Push Buttons<br />

49SAP03<br />

12, 4/4X 0-4<br />

High-Off-Low Selector Switch<br />

49SAS03<br />

17, 18, 36, 37, 83, 84,<br />

Start, Stop Push Buttons<br />

49SAP05<br />

LED,LEF, LEB, CMN a ,<br />

Hand-Off-Auto Selector Switch<br />

49SAS01<br />

CMF a , CMB a<br />

1, 12, 4/4X 0-8 (20-400A)<br />

Keyed Hand-Off-Auto (key removable in all positions) 49SAS09<br />

Off-On Selector Switch<br />

49SAS04<br />

25, 26 1, 12, 4/4X 0-8<br />

Forward, Reverse, Stop Push Buttons<br />

49SAP02<br />

Forward-Off-Reverse Selector Switch<br />

49SAS02<br />

32 1, 12, 4/4X 0-4<br />

High, Low, Stop Push Buttons<br />

49SAP03<br />

High-Off-Low Selector Switch<br />

49SAS03<br />

a To be used for replacement of switch only. Does not<br />

include relay or extra contact block on 30-400A CLM<br />

and CM Lighting Contactors. Class 49SB not available<br />

for these devices.<br />

17-102<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Field Modification Kits<br />

Pilot Lights<br />

Revised on 03/31/20<br />

Selection<br />

Description<br />

Class<br />

Enclosure<br />

Type<br />

Controller Size or<br />

(Lighting Rating)<br />

Lens Color<br />

(Lamp Type) Legend(s) Voltage<br />

Catalog<br />

Number<br />

14, 40, LC,<br />

LEN, CLM<br />

1 (with liftoff<br />

cover)<br />

00–4 or (20–100A)<br />

Red, Green, Amber<br />

(LED lamp)<br />

ON, RUN,<br />

OFF a , OLR<br />

TRIPPED<br />

24 to 240 V AC/DC 49SDLBU<br />

277 V AC 49SDLBL<br />

49SDLBU<br />

14, 17, 18,<br />

36, 37, 40,<br />

83 d , 84 d ,<br />

88, CLM,<br />

CM, LE,<br />

LEN, LC<br />

1 (with<br />

hinged<br />

cover),<br />

3/3R, 4,<br />

4X, 12<br />

00–8 or (20–400A)<br />

Red<br />

ON (Refer to voltage table) 49SPL0BR*<br />

incandecent lamp) c OFF ab (Refer to voltage table) 49SPL0AR*<br />

(Transformer Type<br />

Green<br />

ON (Refer to voltage table) 49SPL0BG*<br />

incandecent lamp) c OFF ab (Refer to voltage table) 49SPL0AG*<br />

(Transformer Type<br />

49SPL0BRF<br />

49SPL0JRF<br />

49SFL0BGU<br />

49SBLBL<br />

52AED2<br />

82, 87 3/3R 1-6<br />

22, 43<br />

22, 25, 26,<br />

43<br />

30<br />

30, 32<br />

1 (with liftoff<br />

cover)<br />

1 (with<br />

hinged<br />

cover),<br />

3/3R, 4,<br />

4X, 12<br />

1 (with liftoff<br />

cover)<br />

1 (with<br />

hinged<br />

cover),<br />

3/3R, 4,<br />

4X, 12<br />

00–4<br />

00-8<br />

0-1 3/4 (1-winding)<br />

0-4 (2-winding)<br />

0-4 (1- or 2-winding)<br />

Red<br />

(LED lamp)<br />

Green<br />

(LED lamp)<br />

Red, Red<br />

(LED lamp)<br />

Green, Green<br />

(LED lamp)<br />

Red, Red<br />

(Transformer Type<br />

incandecent lamp) c<br />

Green, Green<br />

(Transformer Type<br />

incandecent lamp) c<br />

Red, Red<br />

(LED lamp)<br />

Green, Green<br />

(LED lamp)<br />

Red, Red<br />

(Transformer Type<br />

incandecent lamp) c<br />

Green, Green<br />

(Transformer Type<br />

incandecent lamp) c<br />

24 to 240 V AC/DC 49SFL0BRU<br />

ON<br />

277 V AC 49SFL0BRL<br />

24 to 240 V AC/DC<br />

OFF a 49SFL0ARU<br />

277 V AC 49SFL0ARL<br />

24 to 240 V AC/DC 49SFL0BGU<br />

ON<br />

277 V AC 49SFL0BGL<br />

24 to 240 V AC/DC<br />

OFF a 49SFL0AGU<br />

277 V AC 49SFL0AGL<br />

FORWARD,<br />

REVERSE<br />

FORWARD,<br />

REVERSE<br />

FORWARD,<br />

REVERSE<br />

FORWARD,<br />

REVERSE<br />

HIGH,<br />

LOW<br />

HIGH,<br />

LOW<br />

HIGH,<br />

LOW<br />

HIGH,<br />

LOW<br />

24 to 240 V AC/DC 49SDLB7RU<br />

277 V AC 49SDLB7RL<br />

24 to 240 V AC/DC 49SDLB7GU<br />

277 V AC 49SDLB7GL<br />

(Refer to voltage table)<br />

(Refer to voltage table)<br />

49SPL0JR*<br />

49SPL0JG*<br />

24 to 240 V AC/DC 49SDLB7RU<br />

277 V AC 49SDLB7RL<br />

24 to 240 V AC/DC 49SDLB7GU<br />

277 V AC 49SDLB7GL<br />

(Refer to voltage table)<br />

(Refer to voltage table)<br />

49SPL0KR*<br />

49SPL0KG*<br />

Lens Kit for pilot light light kits 49SDLB* Red, Green, Amber — — 49SBLBL<br />

LED lamp BA9s type used to replace<br />

incandecsent or LED lamps. Applies only to<br />

49SP* pilot light kits.<br />

Red<br />

Green<br />

Amber<br />

White<br />

Red<br />

Green<br />

Amber<br />

White<br />

— 24 V AC/DC<br />

— 120 - 600 V AC/DC<br />

52AED2<br />

52AED3<br />

52AED4<br />

52AEDB<br />

52AEB2<br />

52AEB3<br />

52AEB4<br />

52AEBB<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Voltage Table<br />

Voltage Code (*)<br />

24 V AC (Full voltage) J<br />

120 V AC F<br />

240 V AC G<br />

480 V AC H<br />

600 V AC E<br />

a To use as an OFF indicator, the contactor must have a<br />

normally closed (NC) auxiliary contact available for the<br />

circuit. Order separately as needed.<br />

b Includes a nomally closed (NC) auxiliary contact for<br />

NEMA controller sizes 0–4.<br />

c Incandecsent lamps may be replaced with 52AE* LED<br />

lamps listed on this page.<br />

d Class 83 and 84 requires a quantity of two pilot light<br />

kits.<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-103


Field Modification Kits<br />

NEMA, Lighting and Heating Contactors, 20 Amp CLM, CMB, CMF, CMN<br />

Selection<br />

Solid State Control Module Kits For Lighting and Heating Contactors a<br />

CLM 20 Amp<br />

Contactor Kit<br />

Description<br />

120V AC, 50/60 Hz<br />

24V AC/DC,<br />

50/60 Hz<br />

240/277V AC,<br />

50/60 Hz<br />

Accessory<br />

47<br />

(2-Wire<br />

Control)<br />

(2W)<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Accessory<br />

Catalog<br />

Number<br />

List<br />

Price $<br />

Accessory<br />

Catalog<br />

Number<br />

CLM4379771<br />

CLM4379781<br />

CLM4379791<br />

48<br />

49<br />

CLM4379772 (3-Wire CLM4379782 (Start/Stop CLM4379792<br />

Control)<br />

Control)<br />

(3W)<br />

(3WS)<br />

CLM4379773 CLM4379783 CLM4379793<br />

List<br />

Price $<br />

Protective Shielding for NEMA Products<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Class 40<br />

Class 14, 22, 30, 40, 43<br />

Contactor or<br />

Starter Size 00–1 3 ⁄4 List Price $ 2–2 1 ⁄2 List Price $ 3–3 1 ⁄2 List Price $ 4 List Price $<br />

Contactor Shield<br />

Catalog Number<br />

49PSC1 49PSC2 49PSC3 49PSC4<br />

Starter Shield<br />

Catalog Number<br />

49PSS1 49PSS2 49PSS3 49PSS4<br />

Class 17, 25, 32, 87<br />

Disconnect<br />

Size<br />

30A 49PSD5<br />

60 & 100A 49PSD6<br />

200A 49PSD7<br />

Class 14<br />

Catalog<br />

Number List Price $<br />

Disconnect with protective shield<br />

Power Pole Kits Class Enclosure type Contactor Size (Amp) Description<br />

LC Open, 1, 12, 4/4X 30 Single power pole<br />

Double power pole<br />

Field Kit<br />

Catalog No.<br />

49LCPP1A<br />

49LCPP2A<br />

Electrically Held to Mechanically<br />

Held Conversion Modules Class Enclosure type Contactor Size (Amp) Description<br />

LC Open, 1, 12, 4/4X 30 2-wire, 24VAC<br />

2-wire, 110-120VAC<br />

2-wire, 200-277VAC<br />

3-wire, 24VAC<br />

3-wire, 110-120VAC<br />

3-wire, 200-277VAC<br />

Field Kit<br />

Catalog No.<br />

49LCCM1A<br />

49LCCM2A<br />

49LCCM3A<br />

49LCCM4A<br />

49LCCM5A<br />

49LCCM6A<br />

a These kits are only for use with 20A mechanically held<br />

lighting contactors.<br />

17-104<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Field Modification Kits<br />

NEMA, Reduced Voltage and Lighting<br />

Revised on 03/31/20<br />

Selection<br />

Starter/Contactor Auxiliary Contact Kits<br />

Description Class Size Type Catalog Number List Price $<br />

1 NO 49AB10<br />

1 NC 49AB01<br />

1 NC Early Break 49AB01EB<br />

1 NC Late Break 49AB01LB<br />

1 NC Extra Late Break 49AB01XLB<br />

14, 17, 18, 22, 25, 26,<br />

00-4 1 NO Extra Late Make 49AB10XLM<br />

30, 32, 36, 37, 40, 43,<br />

1 NO & 1 NC 49AB11<br />

83, 84, 87, 88<br />

2 NO 49AB20<br />

4 NO 49AB40<br />

3 NO & 1 NC 49AB31<br />

2 NO & 2 NC 49AB22<br />

2 NO 3RH1921-1EA20<br />

14, 17, 18, 22, 25, 26,<br />

5, 6 1 NO & 1 NC 3RH1921-1DA11<br />

36, 37, 40, 43, 87, 88<br />

2 NC 3RH1921-1EA02<br />

14, 17, 18, 22, 25, 26 1 NO & 1 NC (Inside L or R) 49CAL18-11<br />

7, 8<br />

40, 43<br />

1 NO & 1 NC (Outside L or R) 49CAL18-11B<br />

LC 30<br />

1 NO/NC 49LCAC1PA<br />

2 NO/NC 49LCAC2PA<br />

20 Front Mounted 1 NO/NC 3RH2911-1HA11<br />

LE 30-100 Side Mounted 1 NO/NC 3RH2911-1DA11<br />

200-400 Side Mounted 1 NO/NC 3RH1921-1EA11<br />

20 Amps<br />

1 NO/NC SPDT CLM4097291<br />

2 NO/NC SPDT CLM4097292<br />

1 NO & 1 NC CLMFCAK11<br />

2 NC CLMFCAK02<br />

30-200 Amps<br />

2 NO CLMFCAK20<br />

CLM, CMN, CMF, CMB<br />

1 Coil Clearing NO & NC CLMFCCK11<br />

1 NO & 1 NC CLMHCAK11<br />

300-400 Amps<br />

2 NC CLMHCAK02<br />

2 NO CLMHCAK20<br />

1 Coil Clearing NO & NC CLMHCCK11<br />

Disconnect Auxiliary Switch Kits<br />

Disconnect Amp or<br />

Description Class CB Rating Type Catalog Number List Price $<br />

Non-fusible 17, 25, 32, 37, 83, 84,<br />

30 - 200A 2 NO/2 NC DPDT (NEMA A600) HA261234<br />

or Fusible Type 87, 88, LED, LEF, CMN, CMF<br />

MCP 18, 26, 32, 37, 83, 84,<br />

87, 88, LEB, CMB<br />

3A–125A 1 NO/1 NC 240V A02ED62<br />

250A 1 NO/1 NC 480V A02FD64<br />

400A-600A (2) 1 NO/1 NC SPDT-480V A02JLD64<br />

Control Power Transformer Kits a<br />

Recommended Transformer Size VA Transformer Table<br />

Description Control Size Transformer VA Rating Catalog Number List Price $ Primary Volts Secondary Volts Code<br />

00–2 1 ⁄2 45 or 50 45 VA KT*050 b 120 24 1<br />

3–3 1 ⁄2 75 50 VA KT*050P 208 24 G<br />

4 150 100 VA KT*100 208 120 H<br />

5-6 150 150 VA KT*150 240/480 24 4<br />

7-8 300 200 VA KT*200 240/480 120 8<br />

Lighting Control 300 VA KT*300 277 24 5<br />

CLM 500 VA KT*500 277 120 7<br />

20A, 2 - 12P 150 600 24 6<br />

30A, 3P 100 Replace * with code from Transformer table. Kits used with NEMA 1 600 120 9<br />

30A, 6 - 12P 200 general purpose lift-off cover type require extra wide enclosure.<br />

60A, 3P 100 Class 14 Sizes 0-2 1 ⁄2<br />

60A, 4 - 6P 150 Class 30 (2S2W) Sizes 0-2 1 ⁄2<br />

60A, 8 - 12P 250 Class 30 (2S1W) Sizes 0-1 3 ⁄4<br />

100/200A, 3P 200<br />

100/200A, 5P 250<br />

Transformer 300/400A, 3P 250<br />

50/60HZ<br />

LC & LE<br />

LC 30A, 2-12P 100<br />

LE 20, 30, 60A, 3 & 4P 45<br />

LE 30A, 6P 45<br />

LE 30A, 9-12P 100<br />

LE 60A, 6-12P 150<br />

LE 100, 200A, 3P 100<br />

LE 300, 400A, 3P 150<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

a Installation of CPTs may require a larger enclosure.<br />

b 45VA transformer kits will include secondary but not<br />

primary fusing. Sizes 50VA and higher include<br />

2-pole primary fusing and 1-pole secondary fusing.<br />

c For 24VAC control a minimum of 100VA CPT is required.<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-105


Field Modification Kits<br />

ESP200 Accessories<br />

Revised on 01/26/18<br />

Selection<br />

Accessories<br />

Description Catalog Number List Price $<br />

ESP200 Tamper Resistance Cover<br />

49ASTC1<br />

3UB89848<br />

ESP100/200 Mounting Plate<br />

Frame Size Controller Size<br />

A or A1 00 - 1 3/4 49ASMP1<br />

B 2 -2 1/2 49ASMP2<br />

B 3-4 49ASMP3<br />

Mounting Kit 49ASMS1<br />

Universal Reset Operator<br />

8" for class 36, 37 and 87<br />

in NEMA 1, 12 and 3/3R<br />

49MARB<br />

NEMA & General<br />

Purpose Control<br />

Overload Relay Reset Operator<br />

for Class 14, 22, 30 and 83 non-combination starters<br />

in NEMA type 1, 12 and 4/4X enclosures<br />

Overload Relay Reset Operator<br />

for Class 17, 18, 25, 26, 32 and 84 combination starters<br />

in NEMA type 1 enclosures<br />

49MBRS<br />

49MBRS1<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Overload Relay Reset Operator<br />

for Class 17, 18, 25, 26, 32 and 84 combination starters<br />

in NEMA type 12 and 4/4X enclosures<br />

Overload Relay Reset Operator with red button<br />

for any Class in NEMA type 1, 3R, 4/4X and 12 enclosures<br />

with a 30mm hole<br />

49MBRS2<br />

49MARSR<br />

ESP200 Reset Extender 49ASRE<br />

Protective Boot<br />

Offers protection from ice and foreign substances<br />

from interfering with button operation.<br />

For use with 49MARSR reset.<br />

52AABA<br />

Current Transformer 300:5 use with 3UB81234JW2 97CT005<br />

Current Transformer 400:5 use with 3UB81234KW2 97CT006<br />

Current Transformer 600:5 use with 3UB81234LW2 97CT008<br />

Current Transformer 750:5 use with 3UB81234MW2 97CT009<br />

Current Transformer 1200:5 use with 3UB81234NW2 97CT012<br />

17-106<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Field Modification Kits<br />

NEMA Accessories<br />

Selection<br />

Miscellaneous Kits<br />

Encl. Controller Catalog List<br />

Description Class Type Size Number Price $<br />

Mechanical Interlock 00–1 49CCF22H<br />

for Horizontally<br />

Mounted Contactors<br />

Includes wire<br />

14, 40 Open<br />

1 3 ⁄4 49EEF22H<br />

2, 2 1 ⁄2 49GGF22H<br />

3, 3 1 ⁄2 49HHP22H<br />

4 49JJG22H<br />

Interlock Only 5, 6 3RA1954-2A<br />

5 3RA1963-2A<br />

Wire Kit Only<br />

14, 40 Open 6 3RA1973-2A<br />

5 3RA1962-2A<br />

Base Plate Only<br />

6 3RA1972-2A<br />

7 49VM750H<br />

Mechanical Interlock 14, 40 Open<br />

8 49VM1650H<br />

00–1 49CCF22HP<br />

1 3 ⁄4 49EEF22HP<br />

Includes wire &<br />

14, 40 Open 2, 2 1 ⁄2<br />

mounting plate<br />

49GGF22HP<br />

3, 3 1 ⁄2 49HHP22HP<br />

4 49JJG22HP<br />

Includes Left Right<br />

mounting plate 14, 40 Open 2, 2 1 ⁄2 3, 3 1 ⁄2 49L107944<br />

(Different Frame Sizes) 3, 3 1 ⁄2 2, 2 1 ⁄2 49L107945<br />

Surge Suppressor for 120V AC<br />

Surge coil. Limits transient voltage All but<br />

Suppressor produced by the coil to 220% Class LC, LE, CLM<br />

maximum peak line volts.<br />

All 00–4 a 49D26344<br />

Auxiliary NO 36A at 600V AC Max All but<br />

All<br />

49SAF0<br />

00–13⁄4<br />

Power Pole NC 25A at 600V AC Max Class LC, LE, CLM 49SAFC<br />

Top or Bottom, 2-Pole<br />

CLM4097331<br />

Main Contacts<br />

Top, 3-Pole<br />

CLM4097332<br />

CLM All 20 Amps<br />

Lighting Contactors Top or Bottom, 4-Pole CLM4097333<br />

Top or Bottom, 6-Pole<br />

CLM4097334<br />

Load Side<br />

Includes 3 power lugs<br />

Power Take for making extra All but All 00–1 3 ⁄4 49SAE<br />

Off Kit connections to the load Class LC, LE, CLM<br />

side of the contactor<br />

Lug Kit for Contactors For AL/CU Wire 14, 40 All 2-2 1 ⁄2 49SAAF c<br />

3-3 1 ⁄2 49SAAH c<br />

Item Wire Range<br />

4 Line 4 Load 75D35994002 c<br />

49SAAF 2-14<br />

49SAAH 2/0-14<br />

For AL/CU Wire 14, 40 All 5, 6 3RT1966-4G b<br />

75D35994001 250MCM-6<br />

7 49ZATK750-3<br />

Use CU Only 14, 40 All<br />

8 49ZATK1650-6 b<br />

Three Conductor Ground Lug<br />

Kit Meets UL 508 and CSA 2-14 AWG AL/CU Wire All All All 75D28182001<br />

Standard 22.2 No 14-1973<br />

Lightning Arrestor All All All 49D45584002<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Backspin Timer<br />

On delay timer that reduces<br />

risk of starting into a 87, 88 All All<br />

3RP2025-1AQ30<br />

3RP2025-1AP30<br />

backspin<br />

Covers the hole that is<br />

Hole Plug typically used for the 87 All 1-4 49D41149006<br />

conduit hub<br />

Hole Plug<br />

Covers the hole in the enclosure door/cover<br />

40, 43, LC, LE,<br />

normally filled by overload reset 49MBRS.<br />

CLM & CM<br />

Hole plug is used for enclosed contactors.<br />

1 All 49MZPB2<br />

Illustration Description Contactor Wire Size Catalog Number List Price $<br />

Lug Kit<br />

NEMA size 4 (Vacuum)<br />

1 Kit = 1 Terminal block. 1 kit NEMA size 5 2/0 to 600 MCM, max. one 500MCM<br />

necessary for each line and load. NEMA size 6 & one 600MCM<br />

3RT1966-4G<br />

3RT1966-4G<br />

a Surge Suppression for NEMA sizes 5 – 8 are supplied<br />

internal with the coil. For size 4 panel mount.<br />

b Only 3 lugs are suplied for line or load.<br />

If lugs for line and load are required order 2 kits.<br />

c Lug Kit for contactors include 3 lugs for line or load.<br />

75D35994001 for line side.<br />

75D35994002 for load side.<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-107


Field Modification Kits<br />

NEMA Accessories<br />

Revised on 03/31/20<br />

Selection<br />

Fused and Non-Fused Disconnect Switch Kits b<br />

Basic Switch Switch Load Base Load Base<br />

Switch Catalog Catalog Catalog Catalog Lug<br />

Ampere Number List Number List Kit Number List Number List Wire<br />

Rating Non-Fused Price $ Fused Price $ Description Class J Price $ Class H c Price $ Size<br />

30 HNB612 HFB21 30A, 250V — — HBB21 #14-2 AWG (Cu/AI)<br />

HFB612 30A, 600V HBB612 HBB612<br />

60 HNB623 HFB22 60A, 250V — — HBB22 #14-2 AWG (Cu/AI)<br />

HFB62 60A, 600V HBB62 HBB62<br />

100 HNB623 HFB63 100A, 250V — — HBB63 #14-1/0 AWG (Cu/AI)<br />

100A, 600V HBB63<br />

200 HNB64 HFB64 200A, 250V — — HBB64 #6-300 AWG (Cu/AI)<br />

200A, 600V HBB64<br />

Class R Fuse Conversion Kits<br />

Catalog Number Description List Price $<br />

HR21<br />

30A, 240V<br />

HR612<br />

30A, 600V<br />

HR612<br />

60A, 240V<br />

HR62<br />

60A, 600V<br />

HR63 100A, 240/600V<br />

HR64 200A, 240/600V<br />

Metal Conduit Hubs<br />

Description Conduit Size Class<br />

Controller<br />

Size<br />

Enclosure<br />

Type<br />

Milbank<br />

Catalog No. d<br />

NEMA & General<br />

Purpose Control<br />

1"<br />

A7514<br />

1 1/2" A7516<br />

87 All 3R<br />

2" A7517<br />

2 1/2" A7518<br />

CONTROL<br />

PRODUCTS<br />

17<br />

a Product Category: PILO.<br />

b Product Category: HDSS.<br />

c For Class R fuses order Class H kit from this table<br />

and the Class R conversion kit.<br />

d Milbank catalog numbers are for reference only. Milbank<br />

conduit hubs are not sold by Siemens but can be purchased<br />

at a typical electrical hardware and supply distributor.<br />

17-108<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Field Modification Kits<br />

NEMA, Overload Relays<br />

Selection<br />

Sirius 3RB20<br />

Illustration Description For Overload Type Catalog Number List Price $<br />

Reset mechanisms<br />

Reset plunger<br />

Mounts directly to overload relay. Requires 3RB206 3RU1900-1A<br />

separate reset operator in enclosure door. Kit<br />

includes reset plunger, holder and funnel.<br />

Reset plunger with reset button<br />

Cable length<br />

3RU1900-1B<br />

Flexible cable reset mechanism<br />

15.75 in (400mm)<br />

Requires a 6.5 mm hole in the<br />

3RB206<br />

enclosure with a maximum<br />

Cable length<br />

enclosure thickness of 8 mm. 23.62 in (600mm) 3RU1900-1C<br />

Flexible reset<br />

Covers<br />

Tamper resistant cover for current setting and manual/automatic reset button. 3RB206 3RB2984-0<br />

Competitive Retrofit Overload Plates<br />

NEMA<br />

Plate<br />

Manufacturer Size Part Number List Price $<br />

A-B 0, 1 49D57090<br />

A-B 2 49D57161<br />

Sq. D 0, 1 49D57091<br />

Electronic Coil System with Remaining Lifetime Indication and 24VDC PLC Output<br />

21 - 27V 96 - 127V 200 - 277V<br />

Class Size Model Type Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $<br />

All<br />

5<br />

P – – 3RT1965-5PF31 3RT1965-5PP31<br />

V – – 3RT1966-5PF31 3RT1966-5PP31<br />

6<br />

P – – 3RT1975-5PF31 3RT1975-5PP31<br />

V – – 3RT1976-5PF31 3RT1976-5PP31<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-109


Field Modification Kits<br />

Class MT, MTG<br />

Revised on 03/31/20<br />

Selection<br />

Fuse Blocks, Touch-Safe Terminal Covers<br />

Catalog Number Description List Price $<br />

International Fusing a<br />

Catalog Number Description List Price $<br />

KCCF1G<br />

SECONDARY FUSE<br />

BLOCK,1P,250V MAX<br />

1-Pole Fuse Block,<br />

Touch-Safe. Up to 6.3A<br />

for 5 mm u 20 mm or<br />

5 mm u 25 mm (Requires<br />

DIN Rail Mounting)<br />

SINGLE POLE FUSE<br />

BLOCK COVER KIT<br />

8WA1011-1SF12<br />

KCCFBCK<br />

1-Pole Fuse Block,<br />

Touch-Safe 32A, for<br />

10 u 38 mm Cylindrical<br />

Fuses. (Requires DIN<br />

Rail Mounting.)<br />

NEMA & General<br />

Purpose Control<br />

KCCFP2RG<br />

2 Pole PRIMARY FUSE<br />

BLOCK,2P,600V MAX<br />

(block only)<br />

2 Pole PRIMARY FUSE<br />

BLOCK KIT with wire<br />

Leads<br />

3NW7013<br />

2-Pole Fuse Block,<br />

Touch-Safe 32A, for<br />

10 u 38 mm Cylindrical<br />

Fuses. (Requires DIN<br />

Rail Mounting.)<br />

CONTROL<br />

PRODUCTS<br />

17<br />

KCCFPX2R<br />

US2:49FCCPT<br />

Secondary Fuse Clips,<br />

2 per pack<br />

3NW7023<br />

US2:49JUCPT<br />

Terminal Jumpers<br />

1-Pole Fuse Block,<br />

Touch-Safe 4-50A, for<br />

14 u 51 mm Cylindrical<br />

Fuses. (Requires DIN<br />

Rail Mounting.)<br />

Touch safe cover for<br />

secondary fuse clips<br />

3NW7111<br />

US2:KCCSECFCVR<br />

3 pole fuse blk<br />

(2 pole primary and<br />

1 pole secondary)<br />

Fuse Block DIN Rail<br />

Mounting for separate<br />

screw mounting to panel.<br />

(Max 2-pole 2-25A size<br />

per rail.)<br />

(Max 1-pole 4-50A size<br />

per rail.)<br />

US2:KCCFP3POLE<br />

8WA1815<br />

a Product Category: IEC.<br />

17-110<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Heavy Duty Control<br />

Non-Combination Enclosure Kits, Class 49<br />

Revised on 10/15/20<br />

Selection<br />

49 E B 14 E B 11 07 05 R<br />

Class<br />

49 — Field<br />

Kit<br />

Type<br />

E — Enclosure<br />

Only Model<br />

B — Before 2002<br />

C — 2002<br />

Product Class<br />

14 — Class 14, 40<br />

22 — Class 22, 43<br />

30 — Class 30<br />

Starter Size<br />

E — 00, 0, 1, 1 3 ⁄4<br />

G — 2, 2 1 ⁄2<br />

I — 3, 3 1 ⁄2<br />

J — 4<br />

NEMA Type<br />

B — NEMA 1<br />

0 — NEMA 3R/4/12<br />

Width<br />

(In Inches)<br />

Height<br />

(In Inches)<br />

Depth<br />

(In Inches)<br />

Reset Installation<br />

R — Reset<br />

Non-Reversing Starters & Contactors Class 14, 40<br />

NEMA 1<br />

General Purpose (Clamshell) c<br />

NEMA 3R/4/12<br />

Watertight, Dust-tight, Weatherproof d<br />

Without CPT With CPT (Extra Wide) Max.<br />

CPT<br />

Without CPT<br />

With CPT (Extra Wide)<br />

Size Catalog Number Catalog Number VA Catalog Number Catalog Number<br />

00–1 3 ⁄4 49EC14EB110705R 49EC14IB201208R 200 49EB14E0130806R 49EB22E0131306R<br />

2, 2 1 ⁄2 49EC14GB140807R 49EC14IB201208R 200 49EB14G0160907R 49EB22G0161406R<br />

3, 3 1 ⁄2 49EC14IB201208R 49EC14IB201208R 100 49EB14J0261408R 49EB14J0261408R<br />

3, 3 1 ⁄2 — 49EC14JB251409R 250 — —<br />

4 49EC14JB251409R 49EC14JB251409R 300 49EB14J0261408R —<br />

Reversing Starters & Reversing Contactors Class 22, 43<br />

NEMA 1<br />

General Purpose (Clamshell) c<br />

NEMA 3R/4/12<br />

Watertight, Dust-tight, Weatherproof d<br />

Without CPT With CPT (Extra Wide) Max.<br />

CPT<br />

Without CPT<br />

With CPT (Extra Wide)<br />

Size Catalog Number Catalog Number VA Catalog Number Catalog Number<br />

00–1 3 ⁄4 49EC14IB201208R 49EC14IB201208R 200 49EB22E0131306R 49EB22E0131306R<br />

2, 2 1 ⁄2 49EC14IB201208R 49EC14IB201208R 200 49EB22G0161406R 49EB22G0161406R<br />

3, 3 1 ⁄2 49EC14JB251409R 49EC14JB251409R 250 — —<br />

4 49EC14JB251409R 49EC14JB251409R 300 — —<br />

Lighting Contactors Class LC and LE<br />

NEMA 1<br />

General Purpose (Clamshell) c<br />

NEMA 3R/4/12<br />

Watertight, Dust-tight, Weatherproof bd<br />

Without CPT With CPT (Extra Wide) Max.<br />

CPT<br />

Without CPT With CPT (Extra Wide)<br />

Class Size Pole Catalog Number Catalog Number VA Catalog Number Catalog Number<br />

LC 30A 2-12 49EC14GB140807R 49EC14IB201208R 200 49EB22G0161406R 49EB30G0161808R<br />

LE 20A, 30A 3-4 49EC14EB110705R 49EC14IB201208R 200 49EB22G0161406R 49EB22G0161406R<br />

LE 30A 6-9 49EC14IB201208R 49EC14IB201208R 200 49EB22G0161406R 49EB14J0261408R<br />

LE 30A 12 49EC14IB201208R 49EC14JB251409R 250 49EB22G0161406R 49EB14J0261408R<br />

LE 60A 3-6 49EC14GB140807R 49EC14IB201208R 200 49EB22G0161406R 49EB22G0161406R<br />

LE 60A 9-12 49EC14IB201208R 49EC14IB201209R 250 49EB22G0161406R 49EB14J0261408R<br />

LE 100A 3 49EC14IB201208R 49EC14IB201208R 200 49EB14J0261408R 49EB14J0261408R<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Lighting Contactors Class CLM<br />

NEMA 1<br />

General Purpose (Clamshell) ac<br />

NEMA 3R/4/12<br />

Watertight, Dust-tight, Weatherproof bd<br />

Without CPT With CPT (Extra Wide) Max.<br />

CPT<br />

Without CPT With CPT (Extra Wide)<br />

Size Pole Catalog Number Catalog Number VA Catalog Number Catalog Number<br />

20A 2-12 49EC14GB140807R 49EC14IB201208R 200 49EB22G0161406R 49EB22G0161406R<br />

30A 2-5 49EC14EB110705R 49EC14IB201208R 200 49EB22G0161406R 49EB22G0161406R<br />

30A 6-12 49EB30G0161808R 49EB30G0161808R 200 49EB22G0161406R 49EB30G0161808R<br />

60A 2-5 49EC14GB140807R 49EC14IB201208R 250 — —<br />

100A 2-5 49EC14IB201208R 49EC14IB201208R 200 — —<br />

Clamshell enclosure suitable for two operating devices<br />

and two pilot lights. See Field Mods page 17-102.<br />

Hinged cover enclosures, except for<br />

49EB14E0130806R, are suitable for one or more class<br />

52 operating devices and one or more class 52 pilot<br />

lights. See Field Mods page 17-94.<br />

Install NEMA 1 hole plug cat. no. 3SB1902-0AR<br />

(included) when the cover OL reset is not needed.<br />

d Install NEMA 12 hole plug cat. no. 52ABH6 (not<br />

included) when the cover OL reset is not needed.<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-111


Combination Starter Enclosure Kits<br />

Revised on 03/31/20<br />

Features and Benefits<br />

Features<br />

b 100kA short circuit rating when protected with class R fuses<br />

to 600V or MCP to 480V and when installing listed components<br />

from the instruction guide<br />

b Enclosure types available, NEMA 1, 12, 3R and painted NEMA 4.<br />

b Pre-Drilled mounting panels<br />

b Heavy duty quarter turns<br />

b Industrial type disconnect handle<br />

Disconnect Type Enclosure Kit<br />

b Used to assemble both non-fusible and fusible combination starters<br />

b Accommodates Class 14 full voltage non-reversing (FVNR) NEMA<br />

starters 00 – 4 including Siemens exclusive half sizes<br />

b Handle mechanism, power wire, mounting panel, reset assembly,<br />

and instruction guide included. Hardware for panel mounted<br />

devices and disconnect switch are not included<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

MCP Type Enclosure Kit<br />

b Used to assemble combination starters with circuit breakers<br />

b Accommodates Class 14 full voltage non-reversing (FVNR) NEMA<br />

starters 00 – 4 including Siemens exclusive half sizes<br />

b Handle mechanism, power wire, mounting panel, reset assembly<br />

and instruction guide included. Circuit breaker not included however,<br />

mounting hardware for the circuit breaker is.<br />

How to Select the Required Kits to Assemble a Combination Starter<br />

1. From the catalog, select a class 14 open type starter.<br />

2. Based on the starter size, select the enclosure kit from table 1a for<br />

fusible or non-fusible combination starters or select from table 1b<br />

for combination starters with an MCP.<br />

3. For a non-fusible combination starter, select the disconnect switch kit from table 2a.<br />

For a fusible combination starter, select the appropriate disconnect switch, fuse clip<br />

kit, and class R rejection kit from table 2b (for H fusing, class R rejection kit not required).<br />

For combination starters with MCP, select the appropriate circuit breaker kit from table 3.<br />

Nomenclature for Combination Enclosure Kits<br />

49 E C 17 B B 24 11 08 R<br />

Class<br />

49 — Field Kit<br />

Type<br />

E — Enclosure Kit<br />

Model<br />

C — Model C<br />

Product Class<br />

17 — Disconnect Type<br />

18 — Circuit Breaker Type<br />

Enclosure Type<br />

B — NEMA 1<br />

N — NEMA 3R/4/12<br />

Height<br />

(In Inches)<br />

Width<br />

(In Inches)<br />

Depth<br />

(In Inches)<br />

Reset Installation<br />

R — Reset Installed<br />

Disc / CB Amp Rating<br />

B — 30/60 amp disconnect<br />

C — 100 amp disconnect<br />

D— 125 amp breaker frame<br />

E — 150 amp breaker frame<br />

F — 200 amp disconnect<br />

17-112<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Combination Starter Enclosure Kits<br />

Revised on 10/15/20<br />

Selection<br />

Table 1a - FVNR Combination Starter Kits for use with Disconnect Devices<br />

Starter<br />

Size<br />

Disc.<br />

Amp<br />

Rating<br />

NEMA 1<br />

General Purpose<br />

Catalog Number<br />

NEMA 3R/4/12<br />

Watertight, Dust-tight, Weatherproof<br />

Catalog Number<br />

0 - 2 60 49EC17BB241108R 49EC17BN241108R<br />

2 ½ - 3 100 49EC17CB242008R 49EC17CN242008R<br />

Table 1b. – FVNR Combination Starter Kits for use with MCP Devices<br />

Starter<br />

Size<br />

Max<br />

MCP<br />

Amps<br />

NEMA 1<br />

General Purpose<br />

Catalog Number<br />

NEMA 3R/4/12<br />

Watertight, Dust-tight, Weatherproof<br />

Catalog Number<br />

0 - 2 50 49EC18DB241108R 49EC18DN241108R<br />

2 ½ - 3 125 49EC18DB242008R 49EC18DN242008R<br />

Table 2a – Non-Fusible Disconnect Kits<br />

Disconnect Switch<br />

Switch Rating<br />

30A<br />

60A<br />

100A<br />

200A<br />

Catalog Number<br />

HNB612<br />

HNB623<br />

HNB623<br />

HNB64<br />

Table 2b – Fusible Disconnect Kits<br />

Fuse Clip<br />

Ratings<br />

Table 3 – Circuit Breaker Kits<br />

MCP Type Used with Solid State<br />

Overload Relay<br />

Starter<br />

Size<br />

Class<br />

Overload<br />

Amp Range<br />

Rejection Clips<br />

Disconnect Switch Load Base for Fuse for Class R Fusing<br />

Catalog Number Catalog Number Catalog Number<br />

30A-250V H HFB21 HBB21 HR21<br />

30A-600V H HFB612 HBB612 HR612<br />

60A-250V H HFB22 HBB22 HR612<br />

60A-600V H HFB62 HBB62 HR62<br />

100A-250V H HFB63 HBB63 HR63<br />

100A-600V H HFB63 HBB63 HR63<br />

200A-250V H HFB64 HBB64 HR64<br />

200A-600V H HFB64 HBB64 HR64<br />

Motor Circuit<br />

Interrupter Amps<br />

Circuit<br />

Breaker Kit<br />

0.75-3.4 3 ED63A003<br />

0 3-12 10 ED63A010<br />

5.5-22 25 ED63A025<br />

0.75-3.4 3 ED63A003<br />

1 3-12 10 ED63A010<br />

5.5-22 25 ED63A025<br />

10-40 30 ED63A030<br />

1 3 ⁄4 10-40 40 ED63A040<br />

2 13-52 50 ED63A050<br />

2 1 ⁄2 25-100 100 ED63A100<br />

3 25-100 100 ED63A100<br />

3 1 ⁄2 50-200 125 ED63A125<br />

4 50-200 150 FXD63A150L<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-113


Factory Modifications<br />

Revised on 03/31/20<br />

Selection<br />

Ordering Information<br />

All modifications will consist of Siemens standard components as available. Standard equipment dimensions and enclosure construction<br />

may not apply when certain modifications and special features are added.<br />

Pilot Devices<br />

Enclosure<br />

Description Modification Class Type Modification Code List Price $<br />

Start, Stop 14, 17, 18, 36, 37, 40, 83 c , 84 c , CLM, CM, LC, LE All A1<br />

Forward, Reverse, Stop 22, 25, 26, 43 All<br />

Push Buttons High, Low , Stop 30, 32 All<br />

A2<br />

E-Stop 14, 17, 18, 22, 25, 26, 30, 32, 36, 37, 40, 43 All ES<br />

Hand-Off-Auto<br />

14, 17, 18, 36, 37, 40, 83 c , 84 c , LC, LE All A3<br />

CM, CLM All A3<br />

For 24 volt HOA control,<br />

20 Amp contactor only<br />

CM, CLM 1 EM<br />

Off-On<br />

14, 17,18, 22, 25, 26, 30, 32, 36, 37, 40, 43,<br />

83 c , 84 c , CLM, CM, LC, LE<br />

All<br />

A4<br />

Selector Switches Auto-Off 14, 17, 18, 40, 83 c , 84 c , CM, CLM, LC, LE All A6<br />

Forward-Off-Reverse 22, 25, 26, 43 All<br />

High-Off-Low 30, 32 All<br />

A5<br />

Hand-Off-Auto (Keyed) 14, 17, 18, 36, 37, 40, 83 c , 84 c , LC, LE, CLM, CM All A9<br />

Auto-Off-Low-High 30, 32 All A0<br />

NEMA & General<br />

Purpose Control<br />

17<br />

Pilot Lights<br />

Lens Red Green Green LED Bulb<br />

Color ➔ Red Green Red Green Red Green Amber White Push-To-Test Push-To-Test Push-To-Test Upgrade<br />

On On Overload Control On On<br />

For/Rev For/Rev Relay Power For/Rev For/Rev<br />

Enclosure<br />

Legend➔ Low/High Low/High Run Run Off Off Tripped On Low/High Low/High Off<br />

Class Type Mod Code➔ FA FB FC FD FJ FK FL FW FS FT FU FE a<br />

14, 40, 17, 18, 36, 37,<br />

87, 88, LC, LE, CLM, CM All<br />

22, 25, 26, 30, 32, 43,<br />

83 c , 84 c All<br />

CONTROL<br />

PRODUCTS<br />

Coil Options<br />

Class 14, 17, 18, 22, 25, 26, 30, 32, 40, 43, 83 d , 84 d , 87, 88<br />

Coil Letter<br />

Controller Size — List Price $<br />

Volts 60 HZ Volts 50 HZ Change 00–2 1 ⁄2 3, 3 1 ⁄2 4<br />

24 24 J<br />

120 110 F<br />

110–120/220–240 110/190–220 A<br />

200–208 — D<br />

220–240 190–220 G<br />

277 240 L<br />

220–240/440–480 190–220/380–440 C<br />

440–480 380–440 H<br />

575–600 550 E<br />

24V<br />

S e<br />

DC Coil b 48V U<br />

125V<br />

V<br />

.<br />

250V<br />

W<br />

Coil Letter Controller Size 4 (Vacuum Only)<br />

AC (50–60 HZ) or DC Change Size 5 & 6 (ALL)<br />

23–26V J<br />

42–48V U<br />

110–127V F<br />

200–220V D<br />

220–240V G<br />

240–277V L<br />

380–420V K<br />

440–480V H<br />

575–600V E<br />

a Pilot lights are transformer type as standard. For LED<br />

type bulbs, order suffix FE in addition to the standard<br />

device suffix(es). For example, to order red “ON” and<br />

green “OFF” pilot lights with LED bulbs, order FA,<br />

FK and FE.<br />

b DC coils include 1 NC, late break aux. contact.<br />

This aux. contact takes up one side of the starter<br />

(00–4 only).<br />

c For Class 83 and 84, two devices are included.<br />

d For Class 83, 84 standard enclosure (92) alternating<br />

relay available in 24V or 120V control only.<br />

e S coil is not available for size 4 contactors or starters.<br />

17-114<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Factory Modifications<br />

Revised on 03/31/20<br />

Selection<br />

Ordering Information<br />

Replace (*) with letter from Transformer Table.<br />

Transformer Table<br />

Primary Secondary<br />

Volts Volts Letter<br />

120 24 B<br />

208 24 S<br />

208 120 T<br />

240 24 J<br />

240 120 F<br />

277 24 N<br />

277 120 P<br />

380 110 U<br />

415 100 W<br />

480 240 R<br />

480/240 24 D<br />

480/240 120 A<br />

600 24 E<br />

600 120 C<br />

Control Power Transformers<br />

Description<br />

Standard Capacity a<br />

with 1-Secondary Fuse<br />

Modification<br />

Code<br />

B*<br />

Product<br />

Class c<br />

Standard Capacity with 2-Primary<br />

and 1-Secondary Fuse<br />

100VA Extra Capacity with<br />

2-Primary and 1-Secondary Fuse<br />

150VA Extra Capacity with<br />

2-Primary and 1-Secondary Fuse<br />

Factory Assembled Fuse Clips—Class 25, 32, 84 d<br />

Fuse<br />

Clip Amps Volts Modification Code<br />

30 250 10<br />

30 600 11<br />

60 250 12<br />

60 600 13<br />

100 250 14<br />

100 600 15<br />

200 250 16<br />

200 600 17<br />

400 250 18<br />

400 600 19<br />

600 250 20<br />

600 600 21<br />

800 600 23<br />

1200 600 24<br />

1600 600 25<br />

D*<br />

C*<br />

C*1<br />

All<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Note: Factory will furnish the same voltage coils as<br />

transformer secondary voltage (except with class<br />

36,37).<br />

a The standard control transformer supplied for starter<br />

sizes 0 through 2 1 ⁄2 will be rated 45VA and have the<br />

appropriate secondary fuse. Primary fuses will not be<br />

supplied as standard. For primary fuse option select<br />

appropriate suffix from table.<br />

Class 83 and 84 duplex controllers requires two CPTs.<br />

d Class 84 Duplex Controllers require two fusible<br />

disconnects.<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-115


Factory Modifications<br />

Selection<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Additional Auxiliary Contacts<br />

NO NC Modication<br />

Controller Size — List Price $<br />

Class Contacts Contacts Code 00–1 3 ⁄4 2–4 5–6 7–8<br />

— 1 G01 — —<br />

— 2 G02 —<br />

1 — G10 — —<br />

1 1 G11<br />

1 2 G12 — —<br />

2 — G20 —<br />

2 1 G21 — —<br />

2 2 G22 —<br />

2 3 G23 — —<br />

3 1 G31 —<br />

14, 17, 18, 40, 83 c , 84 c 3 2 G32 — —<br />

3 3 G33 — — —<br />

4 — G40 —<br />

4 1 G41 — —<br />

4 2 G42 — — —<br />

4 4 G44 — — —<br />

5 — G50 — —<br />

5 1 G51 — — —<br />

5 3 G53 — — —<br />

6 — G60 — — —<br />

6 2 G62 — — —<br />

7 1 G71 — — —<br />

8 — G80 — — —<br />

— 2 G02 a — —<br />

2 — G20 a — —<br />

2 2 G22 a —<br />

22, 25, 26, 43 & 4 0 G40 a —<br />

30, 32 (2-winding) 4 4 G44 a — —<br />

6 2 G62 a — —<br />

8 0 G80 a — —<br />

0 2 G02 a — — —<br />

2 — G20 a — — —<br />

2 2 G22 a — —<br />

30, 32 4 — G40 a — —<br />

(1-winding) 4 4 G44 a — — —<br />

6 2 G62 a — — —<br />

8 — G80 a — — —<br />

LE, CLM, CM 1 1 G11 — — —<br />

LC 0 1 G01<br />

1 0 G10<br />

1 1 G11<br />

0 2 G02<br />

2 0 G20<br />

LE, CLM, CM 0 2 G02 a — — —<br />

2 0 G20 a — — —<br />

2 2 G22 a — — —<br />

Controller Size - Price Deduction $<br />

Modification<br />

Description Class Code 0, 1 1 3 ⁄4 - 2 1 ⁄2 3 3 1 ⁄2, 4 5, 6 7, 8<br />

Omit Overload Relay and Reset Button 17, 18, 25, 26 EX1<br />

a Auxiliary contacts will be added evenly across<br />

contactors. (i.e. Class 22, G02 suffix will add 2 NC<br />

contacts (one per contactor).<br />

b Double the price addition for Class 30 and 32.<br />

c For class 83 and 84 contacts will be added to both<br />

starters. Price x 2.<br />

17-116<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Factory Modifications<br />

Revised on 03/31/20<br />

Selection<br />

Control Options<br />

Description<br />

Lighting Control Modules (does not include pilot devices) CLM 20 Amp only All<br />

Class<br />

Enclosure<br />

Type<br />

Surge Suppression for 120V AC Coil b 14, 17, 18, 22, 25, 26, 30, 32, 36, 37, 83, 84, 87, 88 All SS<br />

Disconnect Switch Interlock 2 NO/2 NC DPDT 17, 25, 32, 37, 84, CM, LE All GY<br />

Motor Circuit<br />

Protector Interlock<br />

NO/NC SPDT 18, 26, 32, 37, 84, CM, LE All GY<br />

Lightning Arrestor All All L<br />

Circuit Breaker Shunt Trip 18, 26, 32, 37, 84, 87, 88, CM, LE All L6<br />

Circuit Breaker Undervoltage Trip 18, 26, 32, 37, 84, 87, 88, CM, LE All L7<br />

Circuit Breaker Alarm Switch Trip 18, 26, 32, 37, 84, 87, 88, CM, LE All L8<br />

Ground Lug – 3 Conductor All All L10<br />

Control Circuit Fuse and Holder<br />

F1 (1 fuse)<br />

All<br />

All<br />

(Transformer Primary Fusing)<br />

F2 (2 fuses)<br />

Control Circuit Circuit Breaker Internally Operated All All F4<br />

Space Heater (120V separate control) All All SH<br />

Space Heater with Thermostat (120V separate control) All All ST<br />

Surge Capacitor 87, 88 All SC<br />

Alarm Package (includes horn, light, relay & push-button) 83, 84, 87, 88 All M7<br />

Backspin Protection 87, 88 All T5<br />

Blown Control Fuse Indicator Light 17, 25, 32, 37, 84, 87, 88, CM, LC, LE All L11<br />

Minimum Run Timer 0.2 sec. - 3 mins. 87, 88 All T6<br />

Single Phase 120VAC Combination Starter 17, 18, 25, 26 All SP1<br />

Single Phase 240VAC Combination Starter 17, 18, 25, 26 All SP2<br />

Modification Code<br />

2W (2-wire control module)<br />

3W (3-wire control module)<br />

3WS (Start/Stop control module)<br />

Reversing Options<br />

Description<br />

Class<br />

Modification<br />

Code<br />

Reversing in one speed only 2 speed 1 winding<br />

R6<br />

Reversing in one speed only 2 speed 2 winding<br />

R7<br />

30, 32<br />

Reversing in both speeds 2 speed 1 winding<br />

R8<br />

Reversing in both speeds 2 speed 2 winding<br />

R9<br />

Reversing for Reduced Voltage 36, 37 R<br />

NEMA & General<br />

Purpose Control<br />

Motor Management with PROFIBUS DP Communications <br />

Description Class Enclosure Type Modification Code<br />

SIMOCODE pro C With 0.3-3A Current Module<br />

MC1<br />

SIMOCODE pro C With 2.4-25A Current Module<br />

MC2<br />

SIMOCODE pro C With 10-100A Current Module<br />

MC3<br />

SIMOCODE pro C With 20-200A Current Module<br />

MC4<br />

SIMOCODE pro C With 63-630A Current Module<br />

MC5<br />

SIMOCODE pro V With 0.3-3A Current/Voltage Module 14,17,18,22,25,26 All<br />

MV1<br />

SIMOCODE pro V With 2.4-25A Current/Voltage Module<br />

MV2<br />

SIMOCODE pro V With 10-100A Current/Voltage Module<br />

MV3<br />

SIMOCODE pro V With 20-200A Current/Voltage Module<br />

MV4<br />

SIMOCODE pro V With 63-630A Current/Voltage Module<br />

MV5<br />

Factory Parameterization of SIMOCODE<br />

MM0<br />

17 CONTROL<br />

PRODUCTS<br />

Electrically Held to Mechanically Held Conversion Modules<br />

Class Enclosure type Contactor Size (Amp) Description<br />

LC All 30 2-wire, 24VAC<br />

2-wire, 110-120VAC<br />

2-wire, 200-277VAC<br />

3-wire, 24VAC<br />

3-wire, 110-120VAC<br />

3-wire, 200-277VAC<br />

Modification<br />

Code<br />

2W1<br />

2W2<br />

2W3<br />

3W1<br />

3W2<br />

3W3<br />

a Supplied as NEMA 12, field convertible to NEMA 3R.<br />

b Surge Suppression for NEMA sizes 5 – 8 are supplied<br />

internal with the coil.<br />

A CPT must also be ordered to power the motor management<br />

device. Motor management may be ordered<br />

with other product classes as specials.<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-117


Factory Modifications<br />

Revised on 03/31/20<br />

Selection<br />

Control Relays<br />

Enclosure<br />

Type<br />

Description<br />

Class<br />

4 NO<br />

Control Relay 4-Poles Max<br />

2 NO/2 NC All<br />

R22<br />

4 NC R04<br />

Under/Over Voltage, Phase Failure, Phase Sequence, Phase Unbalance<br />

R1<br />

Ground Fault Relay<br />

R5<br />

Electronic On Delay Relay (.15s–100h) 24V/120V<br />

T1<br />

All<br />

Electronic On Delay Relay (.15s–100h) 24V/240V a<br />

T2<br />

Electronic Off Delay Relay (.15s–100s) 120V<br />

All<br />

T3<br />

Electronic Off Delay Relay (.15s–100s) 240V a<br />

T4<br />

24 hour time clock<br />

24 hour time clock with day omission<br />

7 day time clock<br />

Compelling Relay<br />

Acceleration Control<br />

Deceleration Control<br />

Meters—Mounted on Enclosure<br />

LC, LE, CLM, CM<br />

30, 32<br />

Modification<br />

Code<br />

R40<br />

T7<br />

T8<br />

T9<br />

A6<br />

A7<br />

A8<br />

NEMA & General<br />

Purpose Control<br />

Description Class Enclosure Type Modification Code<br />

Ammeter (includes a C.T. if necessary)<br />

1, 3, 4, 4X, 12 M1<br />

Ammeter and Switch (3-Phase with 3 C.T.’s) 14, 17, 18, 22,<br />

1, 12 M2<br />

25, 26, 30 , 32 ,<br />

Voltmeter 1, 3, 4, 4X, 12 M3<br />

36, 37, 40, 43, 83,<br />

Voltmeter and Switch (3-Phase) 84, 87, 88<br />

1, 12 M4<br />

Elapsed Time Meter 1, 3, 4, 4X, 12 M5<br />

Function Identification Plates<br />

Description Class Modification Code<br />

Function identification plate, with marking as specified All N1<br />

Terminal Blocks<br />

17<br />

Description Class Modification Code<br />

3 Point Terminal<br />

6 Point Terminal<br />

9 Point Terminal<br />

All<br />

TC3 <br />

TC6 <br />

TC9 <br />

CONTROL<br />

PRODUCTS<br />

Special Ratings<br />

Description Class Modification Code<br />

Service Entrance Rating<br />

Please note Class 87, 88, CM and LE (combination type)<br />

are UL Listed for Service Entrance as standard and thus<br />

does not need to be modified for such.<br />

17, 18,<br />

25, 26, 32,<br />

37, 84<br />

N3<br />

Drawings<br />

Description Class Catalog Number<br />

Approval/submittal and as-built drawings for factory modified product may<br />

be ordered. The drawing set includes an enclosure outline, a panel layout and<br />

a schematic. When entering the order, use the line item notes to reference a<br />

product and modifications or an existing order that the drawings are to be<br />

engineered for. Specify the contact information and an email address in the<br />

ship to address field. Attach any reference drawings to the order or forward to<br />

National Customer Support. Once completed, the drawing set will emailed.<br />

All<br />

CONTROLDRAWING<br />

a Not available on Class 36, 37.<br />

ETM available with 120V coil only.<br />

For terminal point more than 9 terminals use<br />

additional suffixes. Max 3 suffixes can be selected.<br />

Class 30 and 32 can be modified with only an elapsed<br />

time meter. No other meters apply to class 30 or 32.<br />

17-118<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Manual Control<br />

Heater Elements, Class SMF<br />

Revised on 03/31/20<br />

General<br />

Ordering Information<br />

Heater Elements Class SMF<br />

1. Determine number of heater elements required from Table A.<br />

2. Determine motor full load current and service factor.<br />

3. If the motor and controller are in the same ambient temperature:<br />

a. For 1.15 to 1.25 service factor motors use 100% of motor full load current for heater element selection.<br />

b. For 1.0 service factor motors use 90% of motor full load current for heater element selection.<br />

c. Heater elements are class 20.<br />

4. If the motor and controller are in different ambient temperatures multiply motor full load current by the multiplier in<br />

Table B. Use the resultant full load current for heater element selection.<br />

5. Select proper heater element from table below.<br />

6. All tables are based on the operation of the motor and controller in the same ambient temperature, 40°C (104°F) or<br />

less. Always be certain the correct heater element is installed in the starter before operating the motor.<br />

Heater Motor Full-Load List<br />

Catalog Number Current (Amps) Price $<br />

SMFH01 0.157–0.173<br />

SMFH02 0.174–0.192<br />

SMFH03 0.193–0.212<br />

SMFH04 0.213–0.235<br />

SMFH05 0.236–0.261<br />

SMFH06 0.262–0.289<br />

SMFH07 0.290–0.321<br />

SMFH08 0.322–0.355<br />

SMFH09 0.356–0.399<br />

SMFH10 0.41–0.44<br />

SMFH11 0.45–0.49<br />

SMFH12 0.50–0.53<br />

SMFH13 0.54–0.58<br />

SMFH14 0.59–0.65<br />

SMFH15 0.66–0.71<br />

SMFH16 0.72–0.78<br />

SMFH17 0.79–0.85<br />

SMFH18 0.86–0.96<br />

SMFH19 0.97–1.04<br />

SMFH20 1.05–1.16<br />

SMFH21 1.17–1.25<br />

SMFH22 1.30–1.39<br />

SMFH23 1.38–1.54<br />

SMFH24 1.48–1.63<br />

SMFH25 1.57–1.75<br />

SMFH26 1.66–1.86<br />

Table A<br />

Number of Heater Elements<br />

Number of<br />

Device Heater Elements Notes<br />

SMFF*1<br />

SMFF*2<br />

All single pole and two pole SMF<br />

SMFF*3<br />

1 starters require only 1 Heater<br />

SMFF*4<br />

Element.<br />

SMFF*5<br />

SMFF*6<br />

SMFF*22<br />

Duplex Unit. One Heater Element<br />

2<br />

SMFF*44<br />

per starter.<br />

SMFF*11<br />

Two Speed Starter. One Heater<br />

2<br />

SMFF*22<br />

Element per speed.<br />

Heater Motor Full-Load List<br />

Catalog Number Current (Amps) Price $<br />

SMFH27 1.80–1.99<br />

SMFH28 1.96–2.15<br />

SMFH29 2.16–2.38<br />

SMFH30 2.39–2.75<br />

SMFH31 2.76–2.84<br />

SMFH32 2.85–3.06<br />

SMFH33 3.07–3.45<br />

SMFH34 3.46–3.70<br />

SMFH35 3.71–4.07<br />

SMFH36 4.08–4.32<br />

SMFH37 4.33–4.90<br />

SMFH38 4.91–5.35<br />

SMFH39 5.36–5.85<br />

SMFH40 5.86–6.41<br />

SMFH41 6.42–6.79<br />

SMFH42 6.80–7.57<br />

SMFH43 7.58–8.15<br />

SMFH44 8.16–8.98<br />

SMFH45 8.99–9.67<br />

SMFH46 9.68–9.95<br />

SMFH47 9.96–10.8<br />

SMFH48 10.9–12.1<br />

SMFH49 12.2–13.1<br />

SMFH50 13.2–13.9<br />

SMFH51 14.0–15.0<br />

SMFH52 15.1–16.0<br />

Table B—Special Applications<br />

Heater Element Selection<br />

Ambient Temperature of Motor<br />

Constant 10°C Constant 10°C<br />

Same as (18°F) Higher (18°F) Lower<br />

Continuous<br />

Controller Than Controller Than Controller<br />

Duty Motor<br />

Ambient Ambient Ambient<br />

Service Factor Full Load Current Multiplier<br />

1.15 to 1.25 1.0 0.9 1.05<br />

1.0 0.9 0.8 0.95<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-119


Replacement Parts<br />

Starters and Contactors – AC Coils<br />

Selection<br />

Ordering Information<br />

4th character of starter or contactor catalog number indicates model.<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

AC Coils — For Class 14, 17, 18, 22, 25, 26, 30, 32, 36, 37, 40, 43, 83, 84, 87, 88<br />

Volts<br />

Size Model 60Hz 50Hz Catalog Number List Price $<br />

24 24 75D73070J<br />

120 110 75D73070F<br />

110–120/220–240 110/190–220 75D73070A<br />

P 208 — 75D73070D<br />

00–2 1 ⁄2 U (ESP200) 220–240 190–220 75D73070G<br />

277 240 75D73070L<br />

220–240/440–480 190–220/380–440 75D73070C<br />

440–480 380–440 75D73070H<br />

575–600 550 75D73070E<br />

24 24 75D73251J<br />

120 110 75D73251F<br />

110–120/220–240 110/190–220 75D73251A<br />

P 208 — 75D73251D<br />

3 , 3 1 ⁄2 U (ESP200) 220–240 190–220 75D73251G<br />

277 240 75D73251L<br />

220–240/440–480 190–220/380–440 75D73251C<br />

440–480 380–440 75D73251H<br />

575–600 550 75D73251E<br />

24 24 75D70131J<br />

120 110 75D70131F<br />

120/220–240 110/190–220 75D70131A<br />

G 208 — 75D70131D<br />

4 U (ESP200) 220–240 190–220 75D70131G<br />

277 240 75D70131L<br />

220–240/440–480 190–220/380–440 75D70131C<br />

440–480 380–440 75D70131H<br />

575–600 550 75D70131E<br />

23-26 23-26 3RT1966-5AB31<br />

110-127 110-127 3RT1966-5AF31<br />

200-220 200-220 3RT1966-5AM31<br />

4, 5 V (Vacuum) 220-240 220-240 3RT1966-5AP31<br />

240-277 240-277 3RT1966-5AU31<br />

380-420 380-420 3RT1966-5AV31<br />

440-480 440-480 3RT1966-5AR31<br />

575-600 575-600 3RT1966-5AT31<br />

23-26 23-26 3RT1965-5AB31<br />

110-127 110-127 3RT1965-5AF31<br />

200-220 200-220 3RT1965-5AM31<br />

5 P 220-240 220-240 3RT1965-5AP31<br />

240-277 240-277 3RT1965-5AU31<br />

380-420 380-420 3RT1965-5AV31<br />

440-480 440-480 3RT1965-5AR31<br />

575-600 575-600 3RT1965-5AT31<br />

23-26 23-26 3RT1975-5AB31<br />

110-127 110-127 3RT1975-5AF31<br />

200-220 200-220 3RT1975-5AM31<br />

6 P 220-240 220-240 3RT1975-5AP31<br />

V (Vacuum) 240-277 240-277 3RT1975-5AU31<br />

380-420 380-420 3RT1975-5AV31<br />

440-480 440-480 3RT1975-5AR31<br />

575-600 575-600 3RT1975-5AT31<br />

7 H 100-250 100-250 75ZAF750-70<br />

150-500 150-500 75ZAF750-71<br />

8 H 100-250 100-250 75ZAF1650-70a<br />

a Set of 2 coils. Recommend to change printed circuit<br />

board when changing coils. 49ZP1650 see page 17-121.<br />

17-120<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Replacement Parts<br />

Starters and Contactors – DC Coils, Late Break Aux Contacts, Rectifiers, Contact Kits<br />

Selection<br />

Ordering Information<br />

4th character of starter or contactor catalog number indicates model.<br />

DC Coils for Size 00-4 require Late Break Interlock.<br />

DC Coils — For Class 14, 17, 18, 22, 25, 26, 30, 32, 40, 43<br />

Size Model Volts DC Catalog Number List Price $<br />

12 75D73070R<br />

24 75D73070S<br />

32 75D73070T<br />

00–2 1 ⁄2 P<br />

48 75D73070U<br />

U (ESP200)<br />

125 75D73070V<br />

250 75D73070W<br />

12 75D73251R<br />

24 75D73251S<br />

32 75D73251T<br />

3, 3 1 ⁄2 P<br />

48 75D73251U<br />

U (ESP200)<br />

125 75D73251V<br />

250 75D73251W<br />

4<br />

48 75D70131U<br />

G<br />

125 75D70131V<br />

U (ESP200)<br />

250 75D70131W<br />

23-26 3RT1966-5AB31<br />

4, 5 V (Vacuum) 42-48 3RT1966-5AD31<br />

110-127 3RT1966-5AF31<br />

240-277 3RT1966-5AU31<br />

Note: For sizes 7 & 8 contactors the AC coils are used for DC see page 17-116.<br />

Late Break Auxiliary Contacts<br />

Control Size Model Catalog Number List Price $<br />

00–4 P, G, S, T 49AB01LB<br />

Board for Size 8 Contactor<br />

Control Size Model Catalog Number List Price<br />

8 H 49ZP1650<br />

NEMA & General<br />

Purpose Control<br />

Contact Kits – Single Pole Stationary and Movable Contacts, Contact Spring a<br />

Model<br />

Description Size Number of Poles in Kit (4th position in part number) Catalog Number List Price $<br />

Internal Aux Contact (00-1- 3 ⁄4) P, U 75AF14<br />

00 P, U 75BF14<br />

0 P, U 75CF14<br />

1<br />

1<br />

P, U 75DF14<br />

1 3 ⁄4–1P P, U 75EF14<br />

2 1 P, U 75FP14<br />

2 1 ⁄2 1 P, U 75GP14<br />

3 P, U 75HF14<br />

3 1 1<br />

⁄2<br />

P, U 75IF14<br />

4 1 G, T 75JG14<br />

4 (Vacuum) 3 (Bottles) V, C 3RT1964-6V<br />

Class 14, 17, 18, 22, 25, 5 3 P 3RT1966-6A<br />

26, 30, 32, 36, 37, 40, 43, 5 (Vacuum) 3 (Bottles) V, C 3RT1966-6V<br />

83, 84, 87, 88 6 3 P 3RT1976-6A<br />

6 (Vacuum) 3 (Bottles) V, C 3RT1976-6V<br />

14, 40<br />

7 3 H 49ZL750<br />

8 3 H 49ZL1650<br />

17 CONTROL<br />

PRODUCTS<br />

Armature and Magnet Kits<br />

Size Catalog Number List Price $<br />

00–2 1 ⁄2 49AMSA2<br />

3–3 1 ⁄2 49AMSA3<br />

4 49AMSA4<br />

a On 3-phase controls, all 3-poles should be replaced -<br />

3 kits required.<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-121


Replacement Parts<br />

Lighting Contactors<br />

Revised on 03/31/20<br />

Selection<br />

Power Pole Kits<br />

Class Enclosure type Contactor Size (Amp) Description Catalog No.<br />

LC Open, 1, 12, 4/4X 30<br />

Single power pole<br />

Double power pole<br />

49LCPP1A<br />

49LCPP2A<br />

Replacement Contact Kits<br />

Class Contactor Size (Amp) Description Catalog No.<br />

LC 30 NA NA<br />

LE<br />

20, 30 NA NA<br />

60<br />

100<br />

200<br />

300<br />

400<br />

1 contact kit includes 3 moving<br />

and 6 fixed contacts.<br />

3RT2937-6A<br />

3RT1945-6A<br />

3RT1956-6A<br />

3RT1965-6A<br />

3RT1975-6A<br />

CONTROL<br />

PRODUCTS<br />

17<br />

NEMA & General<br />

Purpose Control<br />

17-122<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: NEMA


Replacement Parts<br />

Lighting Contactors, Type LC, LE, CLM, CMF, CMN<br />

Revised on 12/31/19<br />

Selection<br />

Replacement Coil Kits<br />

Class Contactor Size (Amp) Description Catalog No.<br />

LC<br />

LE<br />

30 24V 60Hz / 20V 50Hz<br />

115-120V 60Hz / 110V 50Hz<br />

200-208V 60Hz<br />

230-240V 60Hz / 220V 50Hz<br />

277V 60Hz / 240V 50Hz<br />

347V 60Hz<br />

460-480V 60Hz / 440V 50Hz<br />

575-600V 60Hz / 550V 50Hz<br />

20, 30 NA NA<br />

60 24VAC 50/60Hz<br />

110VAC 50Hz / 120VAC 60Hz<br />

208VAC 50/60Hz<br />

220VAC 50Hz / 240VAC 60Hz<br />

277VAC 60Hz<br />

480VAC 60Hz<br />

600VAC 60Hz<br />

100 24VAC 50/60Hz<br />

110VAC 50Hz / 120VAC 60Hz<br />

208VAC 50/60Hz<br />

220VAC 50Hz / 240VAC 60Hz<br />

277VAC 60Hz<br />

480VAC 60Hz<br />

600VAC 60Hz<br />

75LCC024A<br />

75LCC120A<br />

75LCC208A<br />

75LCC240A<br />

75LCC277A<br />

75LCC347A<br />

75LCC480A<br />

75LCC600A<br />

3RT29345AC21<br />

3RT29345AK61<br />

3RT29345AM21<br />

3RT29345AP61<br />

3RT29345AU61<br />

3RT29345AV61<br />

3RT29345AT61<br />

3RT29445AC21<br />

3RT29445AK61<br />

3RT29445AM21<br />

3RT29445AP61<br />

3RT29445AU61<br />

3RT29445AV61<br />

3RT29445AT61<br />

LE<br />

200<br />

300<br />

23 - 26 V AC 50-60Hz / DC<br />

110 - 127 V AC 50-60Hz / DC<br />

200 - 220 V AC 50-60Hz / DC<br />

220 - 240 V AC 50-60Hz / DC<br />

240 - 277 V AC 50-60Hz / DC<br />

440 - 480 V AC 50-60Hz / DC<br />

575 - 600 V AC 50-60Hz / DC<br />

23 - 26 V AC 50-60Hz / DC<br />

110 - 127 V AC 50-60Hz / DC<br />

200 - 220 V AC 50-60Hz / DC<br />

220 - 240 V AC 50-60Hz / DC<br />

240 - 277 V AC 50-60Hz / DC<br />

440 - 480 V AC 50-60Hz / DC<br />

575 - 600 V AC 50-60Hz / DC<br />

3RT19555AB31<br />

3RT19555AF31<br />

3RT19555AM31<br />

3RT19555AP31<br />

3RT19555AU31<br />

3RT19555AR31<br />

3RT19555AT31<br />

3RT19655AB31<br />

3RT19655AF31<br />

3RT19655AM31<br />

3RT19655AP31<br />

3RT19655AU31<br />

3RT19655AR31<br />

3RT19655AT31<br />

NEMA & General<br />

Purpose Control<br />

AC Coils 20 Amps b<br />

Type<br />

Contactor<br />

Size<br />

400<br />

Number<br />

of Poles<br />

120V, 60Hz<br />

110V, 50Hz<br />

23 - 26 V AC 50-60Hz / DC<br />

110 - 127 V AC 50-60Hz / DC<br />

200 - 220 V AC 50-60Hz / DC<br />

220 - 240 V AC 50-60Hz / DC<br />

240 - 277 V AC 50-60Hz / DC<br />

440 - 480 V AC 50-60Hz / DC<br />

575 - 600 V AC 50-60Hz / DC<br />

240V, 60Hz<br />

208V, 50Hz<br />

277V<br />

50/60Hz<br />

3RT19755AB31<br />

3RT19755AF31<br />

3RT19755AM31<br />

3RT19755AP31<br />

3RT19755AU31<br />

3RT19755AR31<br />

3RT19755AT31<br />

17 CONTROL<br />

PRODUCTS<br />

CLM4097341<br />

CLM 20 Amp 2–12 CLM4097341 CLM4097342 CLM4097343<br />

AC Coils 30–400 Amps c<br />

CLMC4C120<br />

CLMGU3C120<br />

Type<br />

CLM†C<br />

CLM†D<br />

CLM†E<br />

Contactor<br />

Size<br />

30 Amp<br />

60 Amp<br />

100, 200<br />

Amp<br />

Number Catalog Number<br />

of Poles 24V AC 120V AC 208V AC 220/240V AC 277V AC 480V AC 600V AC<br />

2–3-Pole CLMC4C024 CLMC4C120 CLMC4C208 CLMC4C240 CLMC4C277 CLMC4C480 CLMC4C600<br />

4-Pole CLMC4C024 CLMC4C120 CLMC4C208 CLMC4C240 CLMC4C277 CLMC4C480 CLMC4C600<br />

5-Pole CLMC5C024 CLMC5C120 CLMC5C208 CLMC5C240 CLMC5C277 CLMC5C480 CLMC5C600<br />

2–3-Pole CLMD3C024 CLMD3C120 CLMD3C208 CLMD3C240 CLMD3C277 CLMD3C480 CLMD3C600<br />

4-Pole CLMD5C024 CLMD5C120 CLMD5C208 CLMD5C240 CLMD5C277 CLMD5C480 CLMD5C600<br />

5-Pole CLMD5C024 CLMD5C120 CLMD5C208 CLMD5C240 CLMD5C277 CLMD5C480 CLMD5C600<br />

2–3-Pole CLME3C024 CLME3C120 CLME3C208 CLME3C240 CLME3C277 CLME3C480 CLME3C600<br />

4-Pole CLME5C024 CLME5C120 CLME5C208 CLME5C240 CLME5C277 CLME5C480 CLME5C600<br />

5-Pole CLME5C024 CLME5C120 CLME5C208 CLME5C240 CLME5C277 CLME5C480 CLME5C600<br />

CLM†G<br />

Latching Coil 300/400<br />

2–3-Pole — CLMGL3C120 CLMGL3C208 CLMGL3C240 CLMGL3C277 CLMGL3C480 CLMGL3C600<br />

Unlatch Coil<br />

Amp<br />

2–3-Pole — CLMGU3C120 CLMGU3C208 CLMGU3C240 CLMGU3C277 CLMGU3C480 CLMGU3C600<br />

a Product Category: IEC.<br />

b Coil kits for 20 amp CLM contactors include the coil<br />

clearing auxiliary contact.<br />

c For 30–200 amp CLM contactors, in the event that<br />

either the coil or the control module fails, it is<br />

recommended that both be replaced.<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-123


Replacement Parts<br />

Lighting Contactors, CLM, CMB, CMF & CMN<br />

Revised on 12/31/19<br />

Selection<br />

Ordering Information<br />

For CLM: 5th character of contactor catalog number indicates Frame Size.<br />

For CMB, CMF, CMN: 4th character of contactor catalog number indicates Frame Size.<br />

Main Contacts 20 Amp Lighting Contactors<br />

Contactor Number of Catalog List<br />

Type Size Poles Location Number Price $<br />

CLM4097334<br />

CLM<br />

20 Amp<br />

2 Top or Bottom CLM4097331<br />

3 Top CLM4097332<br />

4 Top or Bottom CLM4097333<br />

6 Top or Bottom CLM4097334<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Main Contacts 30–400 Amp Lighting Contactors<br />

Frame Contactor Number of Catalog List<br />

Type Size Size Poles Number Price $<br />

Auxiliary Contact Blocks 20 Amp Lighting Contactors b<br />

Contactor Catalog List<br />

Type Size Contacts Number Price $<br />

CLM<br />

C<br />

D<br />

20 Amp<br />

Auxiliary Contact Blocks 30–400 Amp Lighting Contactors<br />

Frame Contactor Contact Catalog List<br />

Type Size Size Configuration Number Price $<br />

CLM<br />

30 Amp<br />

60 Amp<br />

CLM E 100 Amp<br />

CLMFCAK11<br />

F<br />

G<br />

H<br />

200 Amp<br />

300 Amp<br />

400 Amp<br />

C to F b<br />

G to H a<br />

2 CLMCCK02<br />

3 CLMCCK03<br />

4 CLMCCK04<br />

5 CLMCCK05<br />

2 CLMDCK02<br />

3 CLMDCK03<br />

4 CLMDCK04<br />

5 CLMDCK05<br />

2 CLMECK02<br />

3 CLMECK03<br />

4 CLMECK04<br />

5 CLMECK05<br />

2 CLMFCK02<br />

3 CLMFCK03<br />

4 CLMFCK04<br />

5 CLMFCK05<br />

2 CLMGCK02<br />

3 CLMGCK03<br />

2 CLMHCK02<br />

3 CLMHCK03<br />

1 Form C NO, NC Contact CLM4097291<br />

2 Form C NO, NC Contacts CLM4097292<br />

30–200 Amps<br />

300–400 Amps<br />

1 NO and 1 NC CLMFCAK11<br />

2 NC CLMFCAK02<br />

2 NO CLMFCAK20<br />

1 Coil Clearing CLMFCCK11<br />

NO and NC<br />

1 NO and 1 NC CLMHCAK11<br />

2 NC CLMHCAK02<br />

2 NO CLMHCAK20<br />

1 Coil Clearing CLMHCCK11<br />

NO and NC<br />

Control Module Rectifier c<br />

Type Device Contactor Size Number of Poles Catalog Number List Price $<br />

CLM<br />

CLM†C to<br />

CLM†F<br />

30–200 Amps All CLMKCMR<br />

a Maximum 1 block per contactor.<br />

b Maximum 2 blocks per contactor.<br />

c For 30–200 amp CLM contactors, in the event that<br />

either the coil or the control module fails, it is<br />

recommended that both be replaced.<br />

17-124<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Replacement Parts<br />

Miscellaneous<br />

Selection<br />

Replacement Handle Assemblies and Disconnect Mechanisms<br />

Enclosure Types 1, 3R, 4, 4X Stainless Steel & 12<br />

Handle Assembly Only<br />

Handle Assembly and<br />

Disconnect Mechanism<br />

Class Disconnect (Amps) Enclosure Size<br />

Catalog Number List Price $ Catalog Number List Price $<br />

17, 25, 32, 84, 87, CM, LE 30, 60 & 100<br />

75D73944015<br />

75D68257103<br />

37, 88 30 & 60 75D73944018 75D68257048<br />

17, 25, 32, 84 200 75D73944015 75D68257105<br />

All Standard and Extra-wide Sizes<br />

37, 88, CM, LE 200 75D73944015 75D68257063<br />

87 200 75D73944023 75D68257068<br />

17, 25, 37, 87, 88, CM, LE 400 & 600 75D73944027 75D68257078<br />

Class<br />

18, 26, 32, CM, LE 3 - 125<br />

Motor Circuit<br />

Interrupter (Amps)<br />

Enclosure Size<br />

(24”H x 11”W x 8”D),<br />

(24”H x 20”W x 8”D)<br />

Handle Assembly Only<br />

Handle Assembly and<br />

Disconnect Mechanism<br />

Catalog Number List Price $ Catalog Number List Price $<br />

75D73944025<br />

75D68257080<br />

18, 26, 32 100 - 125 (36”H x 24”W x 8”D) 75D73944025 75D68257073<br />

18, 26, 32 150 & 250<br />

75D73944028<br />

75D68257089<br />

18, 26, 37, 87, 88, CM 300 - 600 75D73944027 75D68257078<br />

87 3 - 125 75D73944025 75D68257080<br />

87 150 75D73944028 75D68257089<br />

All Standard Sizes<br />

87 250 75D73944011 75D68257077<br />

37, 88 30 - 125 75D73944025 75D68257073<br />

37, 84, 88, CM 150 - 250 75D73944011 75D68257077<br />

84 3 - 125 75D73944025 75D68257074<br />

Quarter Turn Assemblies<br />

NEMA & General<br />

Purpose Control<br />

Description Class Enclosure Type Catalog Number List Price $<br />

Quarter-Turn<br />

Latch<br />

17, 18, 25, 26, 32, 87 & 88<br />

1, 3/3R & 12 75D46260004<br />

4 & 4X 75D46260005<br />

17 CONTROL<br />

PRODUCTS<br />

Product Category: NEMA<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-125


Manual Control<br />

Class SMF, MMS<br />

Dimensions<br />

Class SMF and MMS Open Type<br />

NEMA Type 3R, 4 and 12<br />

(Top and Bottom)<br />

Class SMF<br />

aTypes FO–1, 1P, 2, 2P<br />

(with toggle operator)<br />

Class MMS<br />

aTypes KO–1, 1A, 1B, 2, 2B, 2C<br />

(with toggle operator)<br />

NEMA Type 1B General Purpose Flush Mounting<br />

Device Class Type<br />

Fractional HP Starter<br />

SMF<br />

FWN1, 1P, FWN2, 2P<br />

FWN3, 3P, FW4, 4P<br />

Motor Starting Switch<br />

MMS<br />

KWN1, 1A, 1B, KWN2, 2B, 2C<br />

KWN3, 3A, 3B, KWN4, 4B, 4C<br />

NEMA Type 4 Watertight Die Cast Zinc Enclosure<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Type of<br />

Dimensions in Inches (mm)<br />

Device Operator Type A B C<br />

FF1, 1P, 2, 2P 1.44 2.75 4.50<br />

FS1, 1P, 2, 2P (37) (70) (114)<br />

Toggle<br />

1.44 3.50 5.25<br />

Class SMF<br />

FSJ1P, 2P<br />

(37) (89) (133)<br />

Fractional<br />

FF3, 3P, 4, 4P 1.44 2.75 4.50<br />

HP Starter<br />

FS3, 3P, 4, 4P (37) (70) (114)<br />

Key<br />

1.44 3.50 5.25<br />

FSJ3P, 4P<br />

(37) (89) (133)<br />

KF1, 1A, 1B, 2, 2B, 2C 1.75 2.75 4.50<br />

KS1, 1A, 1B, 2, 2B, 2C (44) (70) (114)<br />

Class Toggle<br />

1.75 3.50 5.25<br />

MMS<br />

KSJ1A, 1B, 2B, 2C<br />

(44) (89) (133)<br />

Motor<br />

Starting<br />

KF3, 3A, 3B, 4, 4B, 4C 1.75 2.75 4.50<br />

Switch<br />

KS3, 3A, 3B, 4, 4B, 4C (44) (70) (114)<br />

Key<br />

1.75 3.50 5.25<br />

KSJ3A, 3B, 4B, 4C<br />

(44) (89) (133)<br />

NEMA Type 1 General Purpose Surface Mounting Enclosures<br />

Dimensions in Inches (mm)<br />

A B C D E F G H I<br />

3.00 2.75 1.13 0.25 3.75 4.69 4.25 4.56 0.78<br />

(76) (70) (28) (6) (95) (119) (108) (116) (20)<br />

Device Class Type<br />

Fractional HP Starter SMF FW1, 1P, 2, 2P<br />

Motor Starting Switch MMS KW1, 1A, 1B, 2, 2B, 2C<br />

Standard Size—Class SMF and MMS<br />

Types FG & KG (Single-Unit)<br />

Note: Dimensions for reference, not for construction.<br />

Dimensions are in inches (mm).<br />

Oversized—Class SMF and MMS<br />

Types FGJ & KGJ (Single-Unit)<br />

a Dimensions typical for key operator devices.<br />

Jumbo MMSKE2<br />

1 ⁄20– 3 ⁄40 Knock-Out On Back and Sides<br />

17-126<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Manual Control<br />

Class SMF, MMS<br />

Dimensions<br />

NEMA Type 7 and 9 Cast Aluminum Enclosure<br />

Dimensions in Inches (mm)<br />

A B C D G H<br />

4.00 5.75 1.38 6.36 4.38 1.20<br />

(101) (146) (35) (161) (111) (30)<br />

Device Class Type<br />

Fractional HP Starter SMF FR1, FR2<br />

Motor Starting Switch MMS KR1, KR2<br />

NEMA Type 1 General Purpose Enclosure For Two Unit Devices<br />

Type of<br />

Device Operator Class Type<br />

One Starter<br />

Toggle SMF FG02, 02P<br />

Key SMF FG04P<br />

Two Starters<br />

Toggle SMF FG222, 222P<br />

Key SMF FG44P<br />

One Starter and Toggle SMF FG71, 71P, 72, 72P<br />

One Sel. Switch a Key SMF FG74P<br />

Reversing Switch b<br />

KG11, 11A, 11B, 22, 22A,<br />

Toggle MRS<br />

22B, 22C<br />

Two Speed Starter Toggle SMF FG11, 11P, 22, 22P<br />

Two Speed Switch Toggle MMS KG11, 11A, 11B, 22, 22B, 22C<br />

NEMA & General<br />

Purpose Control<br />

NEMA Type 1B General Purpose Flush Mounting For Two Unit Devices<br />

Type of<br />

Device c Operator Class Type A B C D<br />

5.25 3.75 5.25 1.44<br />

FF22, 22P<br />

(133) (95) (133) (37)<br />

Toggle SMF<br />

4.56 3.50 4.50 1.44<br />

FS22P<br />

Two (116) (89) (114) (37)<br />

Starters<br />

5.25 3.75 5.25 1.44<br />

FF44P<br />

(133) (95) (133) (37)<br />

Key SMF<br />

4.56 3.50 4.50 1.44<br />

FS44P<br />

(116) (89) (114) (37)<br />

5.25 0.75 5.25 2.00<br />

FF71, 71P, 72, 72P<br />

(133) (19) (133) (51)<br />

One Toggle SMF<br />

4.56 3.50 4.50 2.00<br />

Starter<br />

FS71P, 72P<br />

(116) (89) (114) (51)<br />

and One<br />

Selector<br />

5.25 3.75 5.25 2.00<br />

FF74P<br />

Switch d (133) (95) (133) (51)<br />

Key SMF<br />

4.56 3.50 4.50 2.00<br />

FS74P<br />

(116) (89) (114) (51)<br />

KF11, 11A, 11B<br />

Reversing<br />

5.25 3.75 5.25 1.75<br />

Toggle MRS KF22, 22A<br />

Switch<br />

(133) (95) (133) (44)<br />

22B, 22C<br />

Two<br />

5.25 3.75 5.25 1.44<br />

Speed Toggle SMF FF11, 11P, 22, 22P<br />

(133) (95) (133) (37)<br />

Switch<br />

Two<br />

KF11, 11A, 11B 5.25 3.75 5.25 1.44<br />

Speed Toggle MMS<br />

22, 22B, 22C (133) (95) (133) (37)<br />

Switch<br />

17 CONTROL<br />

PRODUCTS<br />

Note: Dimensions for reference, not for construction.<br />

Dimensions are in inches (mm).<br />

a Selector switch is on the left, increases overall depth<br />

to 3.50 in. (89 mm).<br />

b Only one pilot light (located on right) is used on MRS<br />

switches.<br />

c Dimensions include factory wired power connections.<br />

d Selector switch is on the left, extends 1.62 in. (41 mm)<br />

from mounting surface.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-127


Manual Control<br />

Class 11 - 3RV<br />

Revised on 03/31/20<br />

Dimensions<br />

3RV102<br />

Class 11 - NEMA 1 Enclosure<br />

NEMA & General<br />

Purpose Control<br />

3/4 - 1 NPT<br />

1/2 NPT<br />

1/2 - 3/4 NPT<br />

1/2 - 3/4 NPT<br />

1/2 - 3/4 NPT<br />

1/2 - 3/4 NPT<br />

17<br />

CONTROL<br />

PRODUCTS<br />

10.20<br />

8.63<br />

1/2 - 3/4 NPT<br />

1/4 Mounting Screw<br />

Typ. (3) Places<br />

4.63<br />

6.39<br />

1/2 - 3/4 NPT<br />

5.05<br />

1/2 - 3/4 NPT<br />

3/4 - 1 NPT<br />

Note: Dimensions in inches (millimeters). Dimensions<br />

for reference, not for construction. Contact Sales<br />

Office for dimensions not listed.<br />

17-128<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Heavy Duty Motor Starters<br />

Solid State Overload, Class 14<br />

Dimensions<br />

Figure 1<br />

Figure 1<br />

Figure 2<br />

Figure 2<br />

C<br />

C1<br />

D2<br />

B1<br />

.50 B<br />

.50<br />

C<br />

C1<br />

D2<br />

B1<br />

.50 B<br />

C L<br />

C L<br />

A<br />

D<br />

E<br />

J<br />

A<br />

D<br />

J<br />

L<br />

M<br />

M1<br />

E1<br />

D1<br />

G<br />

M<br />

M1<br />

L<br />

K<br />

E1<br />

D1<br />

B2<br />

G<br />

C<br />

C1<br />

Figure Figure 3 3<br />

D2<br />

.50<br />

B1<br />

B<br />

C1<br />

C<br />

Figure 4 4 Figure 5<br />

.50<br />

B1<br />

B<br />

E2<br />

D2<br />

C L<br />

C L<br />

A<br />

J<br />

J<br />

D<br />

A<br />

D<br />

M<br />

M1<br />

L<br />

K<br />

E1<br />

D1<br />

G<br />

M<br />

M1<br />

L<br />

E1<br />

K<br />

D1<br />

G<br />

NEMA & General<br />

Purpose Control<br />

Open Type Solid State Overload<br />

Mounting<br />

Outline Dimensions Mounting Dimensions Screw Reset Dimensions<br />

Size Figure A B B1 B2 C C1 D D1 D2 E E1 E2 G J K L M M1<br />

00–1 3 ⁄4 1 7.44 3.50 5.75 — 3.75 3.50 6.50 2.00 0.19 6.27 1.00 — #10 5.60 — 0.18 3.23 3.41<br />

(189) (89) (146) (95) (89) (165) (51) (5) (159) (25) (142) (5) (82) (87)<br />

2–2 1 ⁄2 2 8.13 3.50 5.75 4.60 4.00 3.77 7.62 2.00 0.19 — 1.00 — #10 6.87 0.48 0.18 3.88 4.06<br />

(207) (89) (146) (117) (102) (96) (194) (51) (5) (25) (174) (12) (5) (99) (103)<br />

3–3 1 ⁄2 3 9.78 4.50 6.75 — 5.19 4.66 9.22 1.44 0.28 — 0.72 — 0.25 8.43 0.48 0.18 4.04 4.22<br />

(248) (114) (171) (132) (118) (234) (37) (7) (18) (6) (214) (12) (5) (103) (107)<br />

4 4 11.06 4.50 6.75 — 5.75 4.66 10.34 1.44 0.44 — 0.72 0.72 0.25 9.35 0.48 0.18 4.04 4.22<br />

(281) (114) (171) (146) (118) (263) (37) (11) (18) (18) (6) (237) (12) (5) (103) (107)<br />

5 5 12.76 5.71 6.89 — 8.54 — 7.09 4.72 — — — — 0.35 — — — — —<br />

(324) (145) (175) (217) (180) (120) (9)<br />

6 6 13.03 6.30 7.48 — 9.29 — 7.09 5.12 — — — — 0.35 — — — — —<br />

(331) (160) (190) (236) (180) (130) (9)<br />

17 CONTROL<br />

PRODUCTS<br />

Note: Dimensions in inches (millimeters). Dimensions<br />

for reference, not for construction. Contact Sales<br />

Office for dimensions not listed.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-129


L3<br />

Reversing & Multispeed Heavy Duty Starters<br />

Solid State Overload Class 22, 30<br />

Dimensions<br />

D<br />

D1<br />

J<br />

.50<br />

B1<br />

B<br />

Figure 1<br />

C L<br />

Figure 1<br />

C<br />

C1<br />

A<br />

D<br />

D1<br />

J<br />

.50<br />

B1<br />

B<br />

Figure 2<br />

C L<br />

Figure 2<br />

A<br />

C<br />

C1<br />

.50<br />

D1<br />

J<br />

D<br />

B1<br />

B<br />

Figure 3<br />

C L<br />

Figure 3<br />

A<br />

C<br />

C1<br />

L<br />

K<br />

K1<br />

E<br />

B2<br />

G<br />

M1<br />

M<br />

K<br />

K1<br />

B2<br />

G<br />

M1<br />

M<br />

K<br />

K1<br />

E<br />

G<br />

L<br />

M1<br />

M<br />

E<br />

Figure 4 4<br />

Figure 5<br />

Figure 5<br />

D1<br />

.50<br />

B1<br />

B<br />

E<br />

C<br />

C1<br />

.50<br />

B1<br />

E<br />

D1<br />

C<br />

C1<br />

J<br />

J<br />

A<br />

D<br />

D<br />

A<br />

L<br />

NEMA & General<br />

Purpose Control<br />

.50<br />

K<br />

K1<br />

B1<br />

E<br />

Figure 6 6<br />

G<br />

L<br />

D1<br />

M1<br />

M<br />

C<br />

C1<br />

.50<br />

K<br />

K1<br />

B1<br />

E<br />

B<br />

Figure 7Figure 7<br />

G<br />

D1<br />

4.05<br />

4.23<br />

C<br />

C1<br />

J<br />

A<br />

D<br />

J<br />

A<br />

17<br />

L<br />

D<br />

CONTROL<br />

PRODUCTS<br />

K<br />

K1<br />

B<br />

G<br />

M1<br />

M<br />

K<br />

K1<br />

B<br />

G<br />

L<br />

M1<br />

M<br />

Class 22 Reversing & Class 30 2 Speed/2 Winding<br />

Mounting<br />

Outline Dimensions Mounting Dimensions Screw Reset Dimensions<br />

Size Figure A B B1 B2 C C1 D D1 E G J K K1 L M M1<br />

00–1¾ 1 7.69 7.75 10.50 3.62 3.92 3.61 7.25 0.22 7.25 #10 5.77 1.25 4.75 0.18 3.58 3.40<br />

2–2½ 2 8.94 8.25 10.50 3.62 4.17 3.98 8.50 0.22 7.25 #10 7.10 0.77 4.75 0.18 4.23 4.05<br />

3– 3½ 3 11.44 10.94 12.75 — 5.65 5.03 10.75 0.34 10.25 #10 9.18 1.64 6.00 0.18 4.69 4.51<br />

4 4 11.91 10.94 12.75 — 6.22 5.12 11.22 0.34 10.25 0.25 9.53 0.65 6.00 0.18 4.68 4.50<br />

Class 30 2 Speed/1 Winding<br />

Mounting<br />

Outline Dimensions Mounting Dimensions Screw Reset Dimensions<br />

Size Figure A B B1 B2 C C1 D D1 E G J K K1 L M M1<br />

00–1¾ 1 7.69 7.75 10.50 3.62 3.92 3.61 7.25 0.22 7.25 #10 5.77 1.25 4.75 0.18 3.58 3.40<br />

2–2½ 5 9.19 14.55 16.30 — 3.94 3.85 8.75 0.22 13.00 #10 7.33 0.77 5.75 0.18 4.23 4.05<br />

3–3½ 6 11.44 16.94 18.75 — 5.65 5.07 10.75 0.34 16.25 #10 9.18 1.64 6.00 0.18 4.68 4.50<br />

4 7 11.91 16.94 17.75 — 6.22 5.12 10.75 0.82 16.25 #10 9.06 1.64 6.00 0.18 4.68 4.50<br />

Note: Dimensions for reference, not for construction.<br />

Contact sales office for dimensions not listed.<br />

Dimensions are in inches (mm).<br />

17-130<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Heavy Duty Contactors<br />

Class 40<br />

Dimensions<br />

Full Voltage Open Type NEMA Contactor Size 00-8<br />

Figure 1<br />

Figure 2<br />

Figure 3<br />

NEMA & General<br />

Purpose Control<br />

Figure 4<br />

17 CONTROL<br />

PRODUCTS<br />

Open Type<br />

Mounting<br />

Mounting<br />

3rd Character Outline Dimensions Dimensions Screw<br />

Size of Catalog No. a Fig A B B1 B2 C D D1 E G<br />

00–1 3 ⁄4 C, D, E 1 4.31 (110) 3.94 (100) 4.25 (108) 4.75 (121) 3.75 (70) 3.94 (100) 0.19 (5) 1.00 (25) #10<br />

2–2 1 ⁄2 F,G 1 4.88 (124) 3.94 (100) 4.25 (108) — 4.00 (102) 4.50 (114) 0.19 (5) 1.00 (25) #10<br />

3–3 1 ⁄2 H, I 1 6.13 (156) 5.13 (130) 5.50 (140) — 5.06 (129) 5.63 (143) 0.25 (6) 0.75 (19) 0.25 (6)<br />

4 J 1 7.81 (198) 5.19 (132) 5.50 (140) — 5.75 (146) 6.56 (167) 0.81 (21) 0.75 (19) 0.5 (13)<br />

5 L 2 8.27 (210) 5.71 (145) 6.89 (175) — 8.54 (217) 7.09 (180) 4.72 (120) — 0.35 (9)<br />

6 M 2 8.43 (214) 6.3 (160) 7.48 (190) — 9.29 (236) 7.09 (180) 5.12 (130) — 0.35 (9)<br />

7 N 3 14.05 (357) 8.27 (210) — — 9.53 (242) 9.80 (249) 2.83 (72) — 0.25 (6)<br />

8 P 4 15.41 (392) 17.23 (438) — — 10.56 (268) 12.28 (312) — 5.35 (136) 0.35 (9)<br />

Note: Dimensions for reference, not for construction.<br />

Contact sales office for dimensions not listed.<br />

Dimensions are in inches (mm).<br />

a 3rd character of catalog number identifies contactor<br />

rating.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-131


Magnetic Reversing Contactors<br />

Class 43<br />

Dimensions<br />

Figure 1<br />

NEMA & General<br />

Purpose Control<br />

Figure 2<br />

CONTROL<br />

PRODUCTS<br />

17<br />

Open Type Horizontal Mounted<br />

Mounting<br />

Mouning<br />

Outline Dimensions Dimensions Screw<br />

Size Fig. A B B1 C C1 D D1 E F G<br />

00–1 3 ⁄4 1 7.69 (195) 7.75 (197) 9.25 (235) 3.88 (98) — 7.25 (184) 0.25 (6) 3.63 (92) — #10<br />

2, 2 1 ⁄2 1 8.94 (227) 7.75 (197) 9.25 (235) 4.56 (116) — 8.5 (216) 0.25 (6) 3.63 (92) — #10<br />

3–3 1 ⁄2 1 11.44 (291) 10.94 (278) 11.50 (292) 5.19 (132) — 10.75 (273) 0.38 (6) 5.13 (130) — 0.25<br />

4 1 8.50 (216) 10.94 (278) 11.50 (292) 6.25 (159) — 7.81 (198) 0.38 (6) 5.13 (130) — 0.25<br />

5 2 18.07 (459) 14.20 (361) — 9.44 (240) — 17.20 (437) — 9.61 (244) —<br />

6 2 11.61 (295) 18.88 (480) 9.45 (240) 10.85 (276) 7.44 (189) 10.44 (265) 10.71 (272) 17.72 (450) 1.18 (30) —<br />

Note: Dimensions for reference, not for construction.<br />

Contact sales office for dimensions not listed.<br />

Dimensions are in inches (mm).<br />

17-132<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Overload Relays & Current Transformers<br />

Solid State Overload<br />

Dimensions<br />

Dimensions “A” Frame—ESP200 Solid State Overload<br />

Overload (55 - 630 Amps), SIRIUS 3RB20<br />

Dimensions “A1” Frame—ESP200 Solid State Overload<br />

Frame Size A Frame Size A1 Frame Size B<br />

Dimensions mm in. mm in. mm in.<br />

A 80 3.15 80 3.15 100.4 3.95<br />

B 12.6 0.5 12.6 0.5 8.6 0.34<br />

C 27.7 1.1 28 1.10 32.6 1.28<br />

Dimensions “B” Frame—ESP200 Solid State Overload<br />

D 44.85 1.77 44.85 1.77 44.85 1.77<br />

E 34.9 1.37 34.9 1.37 23.5 0.93<br />

F 19.6 0.77 19.6 .077 33.5 1.32<br />

G 48.95 1.93 48.95 1.93 46.23 1.82<br />

H 10.7 0.42 10.7 0.42 10.9 0.43<br />

NEMA & General<br />

Purpose Control<br />

I 2.3 0.09 2.3 0.09 2.4 0.09<br />

J 80 3.15 80 3.15 104.6 4.12<br />

K 53.9 2.12 53.9 2.12 58.6 2.31<br />

L 66.0 2.6 55.9 2.20 50 1.97<br />

M 89.7 3.53 89.7 3.53 114 4.49<br />

N 10.18 0.40 10.18 0.40 4.7 0.19<br />

O — — 10.77 0.42 23.6 0.93<br />

17 CONTROL<br />

PRODUCTS<br />

Current Transformers (all CT’s have the same dimensions)<br />

P — — 8.62 0.34 21.1 0.83<br />

R — — 12.9 0.51 27.1 1.07<br />

S 9.5 0.37 — — 2.45 0.1<br />

T 5.2 0.21 5.2 0.21 5.2 0.21<br />

Note: When mounted on a plate, torque screws to<br />

11 lb.in. (1.2 Nm).<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-133


Lighting & Heating Contactors<br />

Class LC Open Contactors<br />

Dimensions<br />

CONTROL<br />

PRODUCTS<br />

17<br />

NEMA & General<br />

Purpose Control<br />

17-134<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Lighting & Heating Contactors<br />

Open Contactors, Class LE<br />

Dimensions<br />

LEN00B (20A 3 Pole and 4 Pole)<br />

45<br />

73<br />

5 35<br />

57.5<br />

29.8<br />

5<br />

LEN00C003 (30A 3 Pole)<br />

45<br />

97<br />

35.1<br />

4.8<br />

85<br />

43<br />

2.5<br />

75<br />

7.5<br />

NEMA & General<br />

Purpose Control<br />

5<br />

LEN00C004 (30A 4 Pole)<br />

60<br />

45<br />

5<br />

97<br />

5<br />

35.1<br />

4.8<br />

17 CONTROL<br />

PRODUCTS<br />

5<br />

2.5<br />

7.5<br />

87<br />

75<br />

43<br />

50<br />

5<br />

5<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-135


Lighting & Heating Contactors<br />

Open Contactors, Class LE<br />

Revised on 03/31/20<br />

Dimensions<br />

LEN00D003 (60A 3 Pole)<br />

LEN00E003 (100A 3 Pole)<br />

CONTROL<br />

PRODUCTS<br />

17<br />

NEMA & General<br />

Purpose Control<br />

LEN00C006 (30A 6 Pole)<br />

LEN00D006 (60A 6 Pole)<br />

Dimensions in inches.<br />

17-136<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


GROUND<br />

1/ L1 3/ L2 5/ L3<br />

2/ T1<br />

11<br />

21NC<br />

13NO<br />

14NO<br />

22NC<br />

3. 4. 5. 6. A2<br />

3RT20<br />

4/ T2<br />

6/ T3<br />

A1<br />

1/ L1 3/ L2 5/ L3<br />

2/ T1<br />

11<br />

21NC<br />

13NO<br />

14NO<br />

22NC<br />

3. 4. 5. 6.<br />

4/ T2<br />

6/ T3<br />

A1<br />

A2<br />

3RT20<br />

1/ L1 3/ L2 5/ L3<br />

2/ T1<br />

11<br />

21NC<br />

13NO<br />

14NO<br />

22NC<br />

3. 4. 5. 6.<br />

4/ T2<br />

6/ T3<br />

A1<br />

A2<br />

3RT20<br />

Lighting & Heating Contactors<br />

Open Contactors, Class LE<br />

Revised on 03/31/20<br />

Dimensions<br />

LEN00C009 (30A 9 Pole)<br />

LEN00D009 (60A 9 Pole)<br />

11.75<br />

.31 11.13<br />

.31<br />

5.49<br />

Ø.28<br />

(4) MTG.<br />

HOLES<br />

5.87<br />

5.25<br />

NEMA & General<br />

Purpose Control<br />

LEN00C012 (30A 12 Pole)<br />

17 CONTROL<br />

PRODUCTS<br />

LEN00D012 (60A 12 Pole)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-137


Lighting & Heating Contactors<br />

Open Contactors, Class LE<br />

Dimensions<br />

LEN00F003 (200A 3 Pole)<br />

9<br />

17 37<br />

61<br />

107<br />

169<br />

100<br />

SIEMENS<br />

LEN00G003 (300A 3 Pole)<br />

17<br />

140<br />

170<br />

130<br />

7<br />

120<br />

96<br />

48<br />

71<br />

120<br />

NEMA & General<br />

Purpose Control<br />

SIEMENS<br />

168<br />

210<br />

9<br />

180<br />

CONTROL<br />

PRODUCTS<br />

145<br />

132<br />

202<br />

LEN00H003 (400A 3 Pole)<br />

96<br />

48<br />

89<br />

130<br />

9<br />

SIEMENS<br />

182<br />

200<br />

180<br />

160<br />

511<br />

25<br />

150<br />

224<br />

17-138<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Lighting & Heating Contactors<br />

Mechanically / Magnetically Held Lighting Contactors, Class CLM<br />

Dimensions<br />

CLM Contactor, 20 Amp<br />

Figure 1<br />

Figure 2<br />

Figure 3<br />

G<br />

A<br />

B<br />

C<br />

E<br />

F<br />

D<br />

NEMA & General<br />

Purpose Control<br />

Open Type Lighting and Heating Contactors<br />

Class<br />

CLM<br />

Figure<br />

Number<br />

1<br />

2<br />

3<br />

Amp<br />

Rating<br />

Figure is representative and may not depict the<br />

actual number of contactors mounted on the plate.<br />

There will be either 2 or 3 contactors. Furthermore,<br />

each contactor may have 3, 4 or 5 poles.<br />

Number of<br />

Poles A B C D E F G<br />

30 2–4 3.31 (84) 1.65 (42) 3.95 (100) 4.38 (111) 0.23 (6) 4.61 (117) 1.50 (38)<br />

30 5 4.19 (106) 2.09 (53) 3.95 (100) 4.38 (111) 0.23 (6) 4.61 (117) 1.50 (38)<br />

60 2, 3 3.31 (84) 1.65 (42) 3.95 (100) 4.38 (111) 0.23 (6) 4.94 (125) 1.50 (38)<br />

60 4, 5 5.06 (129) 2.53 (64) 3.95 (100) 4.38 (111) 0.23 (6) 4.94 (125) 1.50 (38)<br />

100 2, 3 4.62 (117) 2.31 (59) 6.00 (152) 6.62 (168) 0.38 (10) 6.75 (171) 1.88 (48)<br />

100 4, 5 7.25 (184) 3.62 (92) 6.00 (152) 6.62 (168) 0.38 (10) 6.75 (171) 1.88 (48)<br />

200 2, 3 4.62 (117) 2.31 (59) 6.00 (152) 6.62 (168) 0.38 (10) 6.75 (171) 1.88 (48)<br />

200 4, 5 7.25 (184) 3.62 (92) 6.00 (152) 6.62 (168) 0.38 (10) 6.75 (171) 1.88 (48)<br />

30 6, 8 8.00 (196) 0.31 (8) 5.25 (129) 5.87 (144) 0.31 (8) 4.86 (119) 7.38 (181)<br />

30 9, 10, 12 11.75 (289) 0.31 (8) 5.25 (129) 5.87 (144) 0.31 (8) 4.86 (119) 11.13 (273)<br />

60 6 8.00 (196) 0.31 (8) 5.25 (129) 5.87 (144) 0.31 (8) 5.19 (127) 7.38 (181)<br />

60 8, 9, 10 11.75 (289) 0.31 (8) 5.25 (129) 5.87 (144) 0.31 (8) 5.19 (127) 11.13 (273)<br />

60 12 16.75 (410) 0.31 (8) 5.25 (129) 5.87 (144) 0.31 (8) 5.19 (127) 16.13 (395)<br />

17 CONTROL<br />

PRODUCTS<br />

Note: Dimensions for reference, not for construction.<br />

Dimensions in inches (mm).<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-139


Lighting Control<br />

Mechanically Latched 300 and 400 Amps, Class CLM<br />

Dimensions<br />

CLM Contactors 300 Amp<br />

NEMA & General<br />

Purpose Control<br />

CLM Contactors 400 Amp<br />

CONTROL<br />

PRODUCTS<br />

17<br />

Note: Dimensions for reference, not for construction.<br />

Dimensions in inches (mm).<br />

17-140<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Heavy Duty Motor Starters & Contactors<br />

Enclosed, Class 14, 40<br />

Revised on 10/31/19<br />

Dimensions<br />

Figure 1 Figure 2 Figure 3 Figure 4 Figure 5<br />

View is typical for bottom and top<br />

Outline Dimensions Mounting<br />

Conduit Size Approx.<br />

Enclosure<br />

Ship Reference<br />

Type Size Fig. b A B C D E G a K1 K2 K3 K4 K5 Wt Lbs Drawing<br />

00–1 3/4<br />

1 11.00 6.41 5.00 8.22 4.63 0.25 0.5 0.5-0.75 0.75–1 — — 10 D68870<br />

(w/o CPT)<br />

1<br />

(Standard<br />

width for<br />

use with<br />

or without<br />

CPT)<br />

1<br />

(Extra wide<br />

for use with<br />

CPT)<br />

2–2 1/2<br />

(w/o CPT)<br />

2 13.53 8.00 6.38 10.25 6.00 0.25 0.5-0.75 0.75-1 1–1.25 — — 15 D68870<br />

3–3 1/2 3 19.13 11.38 7.69 15.63 8.25 0.25 0.5-0.75 1–1.25 1.5–2 — — 26 D68870<br />

4 4 24.88 13.38 8.13 21.75 9.00 0.25 0.5-0.75 1.25–1.5 2–2.5 — — 37 D68870<br />

5 5 48.00 24.00 12.00 49.56 22.50 0.38 2–3 135<br />

6, 7 5 48.00 24.00 12.00 49.56 22.50 0.38 2–2.5 150<br />

8 5 60.00 38.00 16.00 61.56 36.50 0.38 275<br />

00–2 1/2 3 19.13 11.38 7.69 15.63 8.25 0.25 0.5-0.75 1–1.25 1.5–2 — — 26 D68870<br />

3–3 1/2 4 24.88 13.38 8.13 21.75 9.00 0.25 0.5-0.75 1.25–1.5 2–2.5 — — 37 D68870<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Note: Dimensions are in inches.<br />

a G designates mounting screw size.<br />

b Enclosures shown in figures 1 - 4 have lift-off covers.<br />

Enclosures shown in figure 5 have hinged covers.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-141


Heavy Duty Motor Starters & Contactors<br />

Enclosed, Class 14, 40<br />

Revised on 03/31/20<br />

Dimensions<br />

Figure 1<br />

Figure 2<br />

G<br />

Figure 3<br />

G<br />

Typical view<br />

top and bottom<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Outline Dimensions Mounting Conduit Size<br />

Approx.<br />

Ship Wt Reference<br />

Enclosure Type Size Fig. A B C D E G a K1 K2 K3 Lbs Drawing<br />

4/4X Fiberglass 0-1 3/4 1 13.00 7.75 5.44 12.25 5.00 0.375 — — — 12 D41547<br />

(Standard width for<br />

use with or without<br />

2-2 1/2 1 16.00 8.13 6.06 15.25 5.00 0.375 — — — 18 D41547<br />

CPT)<br />

3-4 1 26.00 13.13 7.56 25.25 10.00 0.375 — — — 49 D41552<br />

3/3R/4/12<br />

0-1 3/4 2 13.00 7.75 5.44 12.25 5.00 0.25 — — — 12 D41547<br />

(Standard width for 2-2 1/2 2 16.00 8.13 6.06 15.25 5.00 0.25 — — — 18 D41547<br />

use without CPT) 3-4 2 26.00 13.13 7.56 25.25 10.00 0.25 — — — 49 D41552<br />

0–1 3/4 2 13.00 12.63 5.38 12.25 10.00 0.25 — — — 30 D17150<br />

2–2 1/2 2 16.00 13.25 6.13 15.25 11.00 0.25 — — — 33 D17150<br />

3/3R/4/12<br />

3–3 1/2 2 24.00 20.00 8.00 25.56 18.50 0.375 — — — 49 D41552<br />

(Extra wide for use 4 2 30.00 24.00 10.00 31.56 22.50 0.375 — — — 64 D17150<br />

with CPT)<br />

5 3 48.00 24.00 12.00 49.56 22.50 0.375 — — — D65608007<br />

6, 7 3 48.00 24.00 12.00 49.56 22.50 0.375 — — — D65608009<br />

8 3 60.00 38.00 16.00 61.56 36.50 0.375 — — — 275 D65632006<br />

4/4X Stainless Steel 0-1 3/4 2 13.00 7.75 5.44 12.25 5.00 0.25 — — — 18 D41546<br />

(Standard width for 2-2 1/2 2 16.00 8.13 6.06 15.25 5.00 0.25 — — — 36 D41546<br />

use without CPT) 3-4 2 26.00 13.13 7.56 25.25 10.00 0.25 — — — 67 D41551<br />

0–1 3/4 2 13.00 12.63 5.38 12.25 10.00 0.25 — — — 30 D41917<br />

2–2 1/2 2 16.00 13.25 6.13 15.25 11.00 0.25 — — — 33 D42935<br />

4/4X Stainless Steel 3–3 1/2 2 24.00 20.00 8.00 25.56 18.50 0.375 — — — 64 D41551<br />

(Extra wide for use 4 2 30.00 24.00 10.00 31.56 22.50 0.375 — — — 67 D43292<br />

with CPT)<br />

5 (Painted) 3 48.00 24.00 12.00 49.56 22.50 0.375 — — — D65608007<br />

6, 7 (Painted) 3 48.00 24.00 12.00 49.56 22.50 0.375 — — — D65608009<br />

8 3 60.00 38.00 16.00 61.56 26.50 0.375 — — — 275 D65632006<br />

Note: Dimensions are in inches.<br />

a G designates mounting screw size.<br />

17-142<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Combination Heavy Duty Starters<br />

Enclosed, Class 17, 18<br />

Revised on 10/31/19<br />

Dimensions<br />

Figure 1 Figure 2<br />

H<br />

Typical view<br />

top and bottom<br />

7.0 3.0 3.0<br />

H<br />

Typical view<br />

top and bottom<br />

1 /2 X 3 /4<br />

Knockout<br />

6.00<br />

(156)<br />

1 X 1 1 /4<br />

Knockout<br />

B<br />

C<br />

1/2 X 3<br />

1 1 /4<br />

/2 X 2 Knockout<br />

Knockout<br />

B<br />

E<br />

D<br />

1 1 /2 X 2<br />

Knockout<br />

C<br />

G<br />

A<br />

G A<br />

E<br />

D<br />

Mounting<br />

Holes for<br />

1/4" Screws<br />

Qty. 3<br />

E<br />

D<br />

Mounting<br />

Holes for<br />

1/4" Screws<br />

Qty. 4<br />

Figure 3 Figure 4<br />

8.5<br />

3.5 3.5<br />

1<br />

1 1 /2 X 3 /4<br />

/2 X 2<br />

1 1 /2 Knockout X 2<br />

Knockout<br />

Knockout<br />

E<br />

B<br />

D<br />

H<br />

Typical view<br />

top and bottom<br />

C<br />

NEMA & General<br />

Purpose Control<br />

G<br />

E<br />

D<br />

A<br />

Mounting<br />

Holes for<br />

1/4" Screws<br />

Qty. 4<br />

17 CONTROL<br />

PRODUCTS<br />

Outline Dimensions Mounting Dimensions Approx.<br />

Enclosure<br />

Ship Reference<br />

Type Size Fig. A B C D E G H Wt Lbs Drawing<br />

0–2 1 24.00 11.00 8.00 6.13 2.13 21.00 3.50 35 D68774001<br />

1<br />

(Standard<br />

width)<br />

1<br />

(Extra wide)<br />

2 1/2, 3 (except<br />

200A Disc.)<br />

2 24.00 20.00 8.00 15.00 2.13 21.00 3.50 48 D68774002<br />

3 (200A Disc.),<br />

3 1/2, 4<br />

3 36.00 24.00 8.00 14.00 5.00 33.50 5.00 101 D68774003<br />

5 4 72.16 20.00 11.03 71.00 16.00 — — 250 D56032005<br />

6 4 60.00 38.00 12.00 36.50 0.75 61.56 — 275 D56032006<br />

0–2 2 24.00 20.00 8.00 15.00 2.13 21.00 3.50 48 D68774002<br />

2 1/2, 3 3 36.00 24.00 8.00 14.00 5.00 33.50 5.00 101 D68774003<br />

Note: Dimensions are in inches.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-143


Combination Heavy Duty Starters<br />

Enclosed, Class 17, 18<br />

Revised on 10/31/19<br />

Dimensions<br />

Figure 1<br />

Figure 2<br />

Figure 3<br />

5.50<br />

(140)<br />

B<br />

C<br />

E<br />

B<br />

D<br />

C<br />

E<br />

B<br />

D<br />

C<br />

H<br />

G<br />

A<br />

AGH<br />

AGH<br />

E<br />

D<br />

Mounting Holes for<br />

1/4" Screws Qty. 3<br />

Mounting Holes for<br />

1/4" Screws Qty. 4<br />

Mounting Holes for<br />

1/4" Screws Qty. 4<br />

Figure 4<br />

Figure 5<br />

C<br />

NEMA & General<br />

Purpose Control<br />

Mounting Hole<br />

for 1/4" screw<br />

D<br />

A<br />

E<br />

B<br />

Mounting Holes for<br />

No. 10 Screws Qty. 4<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Approx.<br />

Outline Dimensions<br />

Mounting Dimensions<br />

Enclosure<br />

Ship Reference<br />

Type Size Fig. A B C D E G H Wt Lbs Drawing<br />

0–2 1 24.00 11.00 8.00 6.00 2.50 25.75 26.75 35 D56033<br />

3/3R/4/4X/12<br />

(Standard width)<br />

3/3R/4/4X/12<br />

(Extra wide)<br />

4/4X Fiberglass<br />

(Standard width)<br />

2 1/2, 3 (except<br />

200A Disc.)<br />

2 24.00 20.00 8.00 15.00 2.50 25.75 26.75 48 D56033<br />

3 (200A Disc.),<br />

3 1/2, 4<br />

3 36.00 24.00 8.00 12.00 6.00 37.75 38.75 101 D56033<br />

5 (Painted) 4 72.16 20.00 11.03 71.00 16.00 — — 250 D56032005<br />

6 (Painted) 4 60.00 38.00 12.00 36.50 0.75 61.56 63.10 275 D56032006<br />

0–2 2 24.00 20.00 8.00 15.00 2.50 25.75 26.75 48 D56033<br />

2 1/2, 3 3 36.00 24.00 8.00 12.00 6.00 37.75 38.75 101 D56033<br />

0–1 3/4 5 23.75 14.62 7.12 24.09 12.20 — — 42<br />

2–3 1/2 5 23.75 23.75 8.50 24.06 21.30 — — 44<br />

4 5 39.37 29.52 12.20 40.94 27.95 — — 55<br />

Note: Dimensions are in inches.<br />

17-144<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Reversing Heavy Duty Starters & Contactors<br />

Enclosed, Class 22, 43<br />

Revised on 03/31/20<br />

Dimensions<br />

Figure 1<br />

Figure 2<br />

Figure 3<br />

View is typical for bottom and top<br />

Type Size Fig. c G a A B C D E K1 K2 K3 K4 Wt Lbs Drawing<br />

Outline Dimensions Mounting<br />

Conduit Size Approx.<br />

Enclosure<br />

Ship Reference<br />

00–2 1/2 1 19.12 11.38 7.69 15.62 8.25 0.25 0.5-1.25 1-1.25 1.5-2 — 30 D68870<br />

1<br />

(Standard width 3–4 2 24.88 13.38 8.12 21.75 9.00 0.25 1.25-1.5 1.25-1.5 2-2.5 — 52 D68870<br />

for use with or 5 3 48.00 24.00 12.00 49.56 22.50 0.38 1.25-1.5 1.25-1.5 0.5-0.75 1.25-1.5 135 D65608<br />

without CPT)<br />

6, 7 3 48.00 24.00 12.00 49.56 22.50 0.38 1.25-1.5 1.25-1.5 0.5-0.75 1.25-1.5 150 D65608013<br />

0–1 3/4 3 12.00 12.00 6.00 12.75 8.00 0.38 — — — — 30 D41917<br />

2–2 1/2 3 16.00 14.00 6.00 16.75 12.00 0.38 — — — — 33 D42935<br />

4/4X<br />

3–3 1/2<br />

Stainless Steel<br />

3 24.00 20.00 8.00 25.56 18.50 0.38 — — — — 53 D17423<br />

(w/o CPT)<br />

(Standard width<br />

for use without 3–3 1/2<br />

3 30.00 24.00 10.00 31.56 22.50 0.38 — — — — 64 D43292<br />

CPT)<br />

(w/ CPT),4<br />

5 b 3 48.00 24.00 12.00 49.56 22.50 0.38 — — — — D65608007<br />

6, 7 b 3 48.00 24.00 12.00 49.56 22.50 0.38 — — — — 65608009<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Note: Dimensions are in inches.<br />

a G designates mounting screw size.<br />

b Type 4 painted enclosure.<br />

c Enclosures shown in figures 1 and 2 have lift-off covers.<br />

Enclosures shown in figure 3 have hinged covers.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-145


Reversing Heavy Duty Starters & Contactors<br />

Enclosed, Class 22, 43<br />

Revised on 03/31/20<br />

Dimensions<br />

Figure 5 Figure 6<br />

Figure 7<br />

12.50 .188<br />

5.00 10.00<br />

1.20<br />

48.00<br />

45.75<br />

.69<br />

2.38<br />

15.25<br />

20.00<br />

4-POINT MOUNTING<br />

FOR .31 SCREWS<br />

29.88<br />

DOOR<br />

OPEN<br />

90ϒ<br />

A<br />

B C B A<br />

.38 HOLE DIA.<br />

FOR PADLOCK<br />

11.62<br />

2.71<br />

K1<br />

K2<br />

K3<br />

0<br />

0.50<br />

7.25<br />

10.00<br />

12.75<br />

16.50<br />

A COMB. K.O.’s FOR 1.00, 1.25, 1.50, 2.00, OR 2.50 CONDUIT<br />

B COMB. K.O.’s FOR 1.00, 1.25, OR 1.50 CONDUIT<br />

C COMB. K.O.’s FOR 0.50 OR 0.75 CONDUIT<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Enclosure<br />

Type<br />

3/3R/4/12<br />

(Standard width<br />

for use with or<br />

without CPT)<br />

4/4X Fiberglass<br />

(Standard width<br />

for use with or<br />

without CPT)<br />

View is typical for bottom and top<br />

Conduit Size Approx.<br />

Outline Dimensions<br />

Mounting<br />

Size Fig. A B C D E G a K1 K2 K3 Wt Lbs Drawing<br />

Ship Reference<br />

0–1 3/4 5 13.00 12.63 5.63 12.25 10.00 0.25 — — — 30 D17150<br />

2–2 1/2 5 16.00 13.25 6.13 15.25 11.00 0.25 — — — 33 D17150<br />

3–3 1/2<br />

(w/o CPT)<br />

5 24.00 20.00 8.00 25.56 18.50 0.380 — — — 53 D17150<br />

3–4<br />

(w/ CPT)<br />

5 30.00 24.00 10.00 31.56 22.50 0.380 — — — 64 D17150<br />

5 7 48.00 24.00 12.00 49.56 22.50 0.375 — — — D65608007<br />

6 7 48.00 24.00 12.00 49.56 22.50 0.375 — — —<br />

0–2 1/2 6 24.00 20.00 8.00 25.56 18.50 0.380 — — — 35<br />

3–4 6 30.00 24.00 10.00 31.56 22.50 0.380 — — — 38<br />

Note: Dimensions are in inches.<br />

a G designates mounting screw size.<br />

17-146<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Combination Reversing Heavy Duty Starters<br />

Enclosed, Class 25, 26<br />

Revised on 03/31/20<br />

Dimensions<br />

Figure 1 Figure 2 Figure 3<br />

7.0 3.0 3.0<br />

H<br />

Typical view<br />

top and bottom<br />

8.5<br />

3.5 3.5<br />

H<br />

Typical view<br />

top and bottom<br />

E<br />

1 1 1 /2 X 3 /4<br />

/2 X 2 Knockout<br />

Knockout<br />

B<br />

D<br />

1 1 /2 X 2<br />

Knockout<br />

C<br />

1 1 /2 X 2<br />

Knockout<br />

E<br />

1/2 X 3/4<br />

1 1 /2 Knockout X 2<br />

Knockout<br />

B<br />

D<br />

C<br />

G<br />

G A<br />

A<br />

E<br />

D<br />

Mounting<br />

Holes for<br />

1/4" Screws<br />

Qty. 4<br />

E<br />

D<br />

Mounting<br />

Holes for<br />

1/4" Screws<br />

Qty. 4<br />

Figure 4<br />

Figure 5<br />

E<br />

B<br />

D<br />

C<br />

Mounting Holes for<br />

1/4" Screws Qty. 4<br />

AGH<br />

NEMA & General<br />

Purpose Control<br />

Outline Dimensions Mounting Dimensions Approx.<br />

Enclosure<br />

Type Size Fig. A B C D E G H<br />

Ship<br />

Wt Lbs<br />

Reference<br />

Drawing<br />

0–2 1/2 1 24.00 20.00 8.00 15.00 2.13 21.00 3.50 60 D68774002<br />

1<br />

3-4 2 36.00 24.00 8.00 14.00 5.00 33.50 5.00 121 D68774003<br />

(Standard<br />

width)<br />

5 3 72.16 20.00 11.03 71.00 16.00 — — 250 D56032005<br />

6 3 72.10 40.20 18.10 78.00 18.00 — — 275 D56032006<br />

0–2 1/2 5 24.00 20.00 8.00 15.00 3.50 25.75 26.75 63 D68774005<br />

3/3R/4/4X/12 3-4 5 36.00 24.00 8.00 14.00 6.00 37.75 38.75 124 D68774006<br />

(Standard<br />

width)<br />

5(Painted) 3 72.16 20.00 11.03 71.00 16.00 — — 250 D56032005<br />

6(Painted) 3 72.10 40.20 18.10 78.00 18.00 — — 275 D56032006<br />

17 CONTROL<br />

PRODUCTS<br />

Outline Dimensions<br />

Mounting<br />

Conduit Size Approx.<br />

Enclosure<br />

Ship Reference<br />

Type Size Fig. A B C D E G a K1 K2 K3 Wt Lbs Drawing<br />

4/4X Fg 0-2 1/2 4 24.00 20.00 8.00 25.56 18.50 0.38 — — — 18 24-139-861-001<br />

(Standard<br />

width)<br />

3-4 4 30.00 24.00 10.00 31.56 22.50 0.38 — — — 28 24-139-861-003<br />

Note: Dimensions are in inches.<br />

a G designates mounting screw size.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-147


Two Speed Heavy Duty Starters<br />

Enclosed, Class 30<br />

Revised on 03/31/20<br />

Dimensions<br />

Figure 1<br />

Figure 1a<br />

Figure 2<br />

Figure 3 Figure 4<br />

K1 K2 K3<br />

A<br />

D<br />

A<br />

D<br />

G<br />

E<br />

B<br />

G<br />

E<br />

B<br />

C<br />

C<br />

K1 K2 K3<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Starter Type<br />

(Enclosure<br />

Outline Dimensions Mounting Conduit Size<br />

Type) Size Fig. b A B C D E G a K1 K2 K3<br />

2 Speed 1 Winding<br />

(Type 1 for use<br />

with or without<br />

CPT)<br />

2 Speed 1 Winding<br />

(Type 4/4X<br />

Stainless Steel for<br />

use with or without<br />

CPT)<br />

2 Speed 1 Winding<br />

(Type 3/3R/4/12 for<br />

use with or without<br />

CPT)<br />

2 Speed 1 Winding<br />

(Type 4/4X Fg. for<br />

use w/ or w/o CPT)<br />

2 Speed 2 Winding<br />

(Type 1 for use<br />

with or without<br />

CPT)<br />

2 Speed 2 Winding<br />

(Type 4/4X<br />

Stainless Steel for<br />

use with or without<br />

CPT)<br />

2 Speed 2 Winding<br />

(Type 3/3R/4/12 for<br />

use with or without<br />

CPT)<br />

2 Speed 2 Winding<br />

(Type 4/4X Fg. for<br />

use w/ or w/o CPT)<br />

Approx.<br />

Ship<br />

Wt Lbs<br />

Reference<br />

Drawing<br />

0–1 3/4 w/o CPT 1 19.13 11.38 7.69 15.63 8.25 0.25 0.5-0.75 1.0-1.25 1.5-2 26 D68870<br />

0–1 3/4 w/ CPT 1a 24.88 13.38 8.13 21.75 9.00 0.25 0.5-0.75 1.25-1.5 2-2.5 52 D68870<br />

2–2 1/2 2 16.00 17.13 7.63 15.25 14.00 0.25 0.5-0.75 1.25-1.5 1.25-1.5 39 D42932001<br />

3–3 1/2 2 24.88 13.38 8.13 21.75 9.00 0.25 0.5-0.75 1.25–1.5 2–2.5 60 D72956002<br />

4 3 24.88 13.38 8.13 21.75 9.00 0.25 0.5-0.75 1.25–1.5 2–2.5 61 D43292001<br />

0–1 3/4 w/o CPT 3 12.00 12.00 6.00 12.75 10.00 0.38 — — — 34 D41917000<br />

0–1 3/4 w/ CPT 3 16.00 16.00 8.00 17.60 14.50 0.38 — — — 47<br />

2–2 1/2 w/o CPT 3 16.00 16.00 8.00 17.60 14.50 0.38 — — — 47<br />

2–2 1/2 w/ CPT 3 30.00 24.00 10.00 31.56 22.50 0.38 — — — 55<br />

3–3 1/2 3 30.00 24.00 10.00 31.56 22.50 0.38 — — — 61 D43292001<br />

4 3 30.00 24.00 10.00 31.56 22.50 0.38 — — — 61 D43292001<br />

0–1 3/4 w/o CPT 3 13.00 12.63 5.38 12.25 10.00 0.25 — — — 34<br />

0–1 3/4 w/ CPT 3 16.00 17.13 7.63 15.25 14.00 0.25 — — — 47 D17150010<br />

2–2 1/2 w/o CPT 3 16.00 17.13 7.63 15.25 14.00 0.25 — — — 47 D17150010<br />

2–2 1/2 w/ CPT 3 24.00 20.00 8.00 25.56 18.50 0.38 — — — 55<br />

3–4 3 30.00 24.00 10.00 31.56 22.50 0.38 — — — 61 D19673000<br />

0–2 1/2 4 23.78 23.78 6.89 — — 0.25 — — — 28 24139861003<br />

3–4 4 39.38 29.53 12.60 — — — — — — 24139861004<br />

0–2 1/2 w/o CPT 1 19.13 11.38 7.69 15.63 8.25 0.25 0.5-0.75 1.0-1.25 1.5-2 30 D68870<br />

0–2 1/2 w/ CPT 1a 24.88 13.38 8.13 21.75 9.00 0.25 0.5-0.75 1.25-1.5 2-2.5 52 D68870<br />

3–4 w/o CPT 1a 24.88 13.38 8.13 21.75 9.00 0.25 0.5-0.75 1.25-1.5 2-2.5 52 D68870<br />

0–1 3/4 w/o CPT 3 12.00 12.00 6.00 12.75 10.00 0.38 — — — 34<br />

0–1 3/4 w/ CPT 3 16.00 16.00 8.00 17.60 14.50 0.38 — — — 41<br />

2–2 1/2 w/o CPT 3 16.00 16.00 8.00 17.60 14.50 0.38 — — — 41<br />

2–2 1/2 w/ CPT 3 16.00 16.00 8.00 17.60 14.50 0.38 — — — 41<br />

3–3 1/2 w/o CPT 3 30.00 24.00 10.00 31.56 22.50 0.38 — — — 55<br />

3–3 1/2 w/ CPT 3 30.00 24.00 10.00 31.56 22.50 0.38 — — — 61 D43292001<br />

4 3 30.00 24.00 10.00 31.56 22.50 0.38 — — — 61 D43292001<br />

0–1 3/4 w/o CPT 3 13.00 12.63 5.38 12.25 10.00 0.25 — — — 34<br />

0–1 3/4 w/ CPT 3 16.00 17.13 7.63 15.25 14.00 0.25 — — — 41 D17150010<br />

2–2 1/2 w/o CPT 3 16.00 13.25 6.13 15.25 11.00 0.25 — — — 41<br />

2–2 1/2 w/ CPT 3 16.00 17.13 7.63 15.25 14.00 0.25 — — — 41 D17150010<br />

3–3 1/2 w/o CPT 3 24.00 20.00 8.00 25.56 18.50 0.38 — — — 55<br />

3–4 w/CPT 3 30.00 24.00 10.00 31.56 22.50 0.38 — — — 61 D19673000<br />

0–2 1/2 4 23.78 23.78 6.89 — — 0.25 — — — 28 24139861003<br />

3–4 4 39.38 29.53 12.60 — — — — — — 24139861004<br />

Note: Dimensions are in inches. a G designates mounting screw size. b Enclosures shown in figures 1and 1a have lift-off covers.<br />

Enclosures shown in figures 2, 3 and 4 have hinged covers.<br />

17-148<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Combination Two Speed Heavy Duty Starters<br />

Enclosed, Class 32<br />

Dimensions<br />

Figure 1 Figure 2<br />

7.0 3.0 3.0<br />

8.5<br />

3.5 3.5<br />

H<br />

Typical view<br />

top and bottom<br />

H<br />

Typical view<br />

top and bottom<br />

E<br />

1 1 /2 X 2<br />

Knockout<br />

1/2 X 3 /4<br />

Knockout<br />

B<br />

D<br />

1 1 /2 X 2<br />

Knockout<br />

C<br />

1 1 /2 X 2<br />

Knockout<br />

E<br />

1/2 X 3 /4<br />

1 1 /2 Knockout X 2<br />

Knockout<br />

B<br />

D<br />

C<br />

G<br />

G A<br />

A<br />

E<br />

D<br />

Mounting<br />

Holes for<br />

1/4" Screws<br />

Qty. 4<br />

E<br />

D<br />

Mounting<br />

Holes for<br />

1/4" Screws<br />

Qty. 4<br />

Figure 4<br />

Figure 3<br />

E<br />

B<br />

D<br />

C<br />

NEMA & General<br />

Purpose Control<br />

AGH<br />

NEMA 1 Standard Width 0–4<br />

Mounting Holes for<br />

1/4" Screws Qty. 4<br />

Outline Dimensions<br />

Mounting<br />

Approx<br />

Dimensions<br />

Ship Wt<br />

Size Figure A B C D E G H Lbs (Kg) Ref Dwg<br />

0–1 3 ⁄4 (1 Winding) 1 24 (610) 20 (508) 8 (203) 15.00 (381) 2.125 (54) 21.00 (533) 3.50 (90) 68 (31) D68774<br />

2–4 (1 Winding) 2 36 (914) 24 (610) 8 (203) 14.00 (356) 5.00 (127) 33.50 (851) 3.50 (90) 71 (32) D68774<br />

0–2 1 ⁄2, (2 Winding) 1 24 (610) 20 (508) 8 (203) 15.00 (381) 2.125 (54) 21.00 (533) 3.50 (90) 135 (61) D68774<br />

3–4 (2 Winding) 2 36 (914) 24 (610) 8 (203) 14.00 (356) 5.00 (127) 33.50 (851) 3.50 (90) 138 (63) D68774<br />

17 CONTROL<br />

PRODUCTS<br />

NEMA 12/3/3R/4 (Painted), 4/4X Stainless Standard Width 0–4<br />

0–1 3 ⁄4 (1 Winding) 4 24 (610) 20 (508) 8 (203) 15.00 (381) 2.50 (64) 25.75 (654) 26.75 (680) 68 (31) D68774<br />

2–4 (1 Winding) 4 36 (914) 24 (610) 8 (203) 12 (305) 6.00 (152) 37.75 (959) 38.75 (984) 71 (32) D68774<br />

0–2 1 ⁄2, (2 Winding) 4 24 (610) 20 (508) 8 (203) 15.00 (381) 2.50 (64) 25.75 (654) 26.75 (680) 135 (61) D68774<br />

3–4 (2 Winding) 4 36 (914) 24 (610) 8 (203) 12 (305) 6.00 (152) 37.75 (959) 38.75 (984) 138 (63) D68774<br />

Nema 4X Fiberglass 0–4<br />

Outline Dimensions Mounting Dimensions Mtg Screw Conduit Size Approx Ship Wt<br />

Size Figure A B C D E G K1 K2 K3 Lbs (Kg) Ref Dwg<br />

0–1 3 ⁄4 3 23.780 (604) 14.680 (373) 6.890 (175) 24.125 (613) 12.250 (311) 1<br />

⁄4 — — — 18 (8) —<br />

2–4 3 23.780 (604) 23.780 (604) 6.890 (175) 24.125 (613) 21.250 (540) 1<br />

⁄4 — — — 28 (13) —<br />

Note: Dimensions in inches (mm).<br />

Dimensions for reference, not for construction.<br />

Contact sales office for dimensions not listed.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-149


Reduced Voltage Starters<br />

Class 36, 37, 82<br />

Revised on 10/31/19<br />

Dimensions<br />

Figure 1<br />

Figure 2<br />

B<br />

H<br />

C<br />

K<br />

C<br />

L<br />

Handle<br />

(Optional)<br />

(4) .687 Dia Holes<br />

D<br />

A<br />

Restricted Area<br />

for<br />

Auto Transformer<br />

D<br />

A<br />

E<br />

G<br />

Mounting Hole<br />

for 1/4" screw<br />

E<br />

B<br />

J<br />

Class 36, 37, NEMA 1, 4, 4X, 12/3R, Combination and Non-combination<br />

NEMA & General<br />

Purpose Control<br />

Enclosure<br />

Type<br />

1, 4/4X &<br />

12/3R<br />

Class 82 size 1<br />

.25<br />

Size<br />

AutoTransformer Part Winding & Wye Delta<br />

Outline Dimensions<br />

Disc. & MCP Type Disc. Type MCP Type Fig. A B C D E<br />

1 3/4–2 1/2 0–2 0–2 1/2 1 42.00 32.00 12.00 43.60 30.50<br />

3–3 1/2 2 1/2–3 1/2 3–3 1/2 1 48.00 38.00 12.00 49.60 36.50<br />

4 4 4 1 60.00 38.00 12.00 61.60 36.50<br />

5, 6 5, 6 5, 6 2 90.00 29.97 20.00 16.00 24.44<br />

2.88<br />

3.50<br />

5.57<br />

3.50<br />

10.93<br />

1/4-20 x1/2"<br />

SCREW<br />

3.06<br />

2.75<br />

Reference<br />

Drawing<br />

2.88<br />

3.50<br />

3.50<br />

17<br />

CONTROL<br />

PRODUCTS<br />

1.68<br />

24.27 .37<br />

2.13<br />

1.81 25.00<br />

∅2.85 O.D. FLANGED<br />

26.13<br />

CONDUIT OPENING<br />

∅1.375, ∅1.700, ∅2.000, ∅2.500<br />

MOUNTING HOLES FOR<br />

ECCENTRIC KNOCKOUT<br />

5/16" HARDWARE<br />

∅1.125, ∅1.385, ∅1.750, ∅2.000<br />

5.02<br />

ECCENTRIC KNOCKOUT<br />

(2 PLACES)<br />

5.08<br />

ALL DIMENSIONS IN INCHES<br />

START BUTTON<br />

HAND-OFF-AUTO SELECTOR SWITCH<br />

Class 82 Size 1 1/2, 2<br />

Note: Dimensions are in inches.<br />

17-150<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Duplex Heavy Duty Controllers<br />

Class 83, 84<br />

Revised on 03/31/20<br />

Dimensions<br />

Figure 1<br />

Figure 2 Figure 3<br />

A<br />

Class 83 Non-Combination Type<br />

Enclosure<br />

Type Size Fig.<br />

Outline Dimensions<br />

Mounting<br />

Conduit Size<br />

A B C D E G a K1 K2 K3 K4 K5<br />

1 0–1 3/4 1 20.00 20.00 6.00 21.60 18.50 0.38 — — — — — 20<br />

2, 2 1/2 1 24.00 20.00 8.00 25.60 18.50 0.38 — — — — — 57<br />

3–4 1 30.00 24.00 10.00 31.60 22.50 0.38 — — — — — 93<br />

3/3R/4/12 0–1 3/4 2 20.00 20.00 6.00 21.60 18.50 0.38 — — — — — 20<br />

2, 2 1/2 2 24.00 20.00 8.00 25.60 18.50 0.38 — — — — — 57<br />

3–4 2 30.00 24.00 10.00 31.60 22.50 0.38 — — — — — 93<br />

4X<br />

Stainless<br />

Steel<br />

0–1 3/4 2 20.00 16.00 6.00 21.60 14.50 0.38 — — — — — 20<br />

2, 2 1/2 2 24.00 20.00 8.00 25.60 18.50 0.38 — — — — — 57<br />

3–4 2 30.00 24.00 10.00 31.60 22.50 0.38 — — — — — 93<br />

Approx.<br />

Ship<br />

Wt Lbs<br />

Reference<br />

Drawing<br />

NEMA & General<br />

Purpose Control<br />

Class 84 Combination Type<br />

Enclosure<br />

Type Size Fig.<br />

1, 12/3/3R/4<br />

4X<br />

Stainless<br />

Steel<br />

Outline Dimensions<br />

Mounting<br />

Conduit Size<br />

A B C D E G a K1 K2 K3 K4 K5<br />

0–2 3 34.13 24.63 7.56 33.00 20.00 0.38 0.88 – 1.13 0.88 – 1.13 1.13 – 1.36 1.13 – 1.36 1.36 – 1.72 70<br />

2 1/2–4 3 48.00 36.00 10.00 49.60 34.50 0.38 — — — — — 106<br />

0–2 3 36.00 24.00 10.00 37.60 22.50 0.38 — — — — — 70<br />

2 1/2–4 3 48.00 36.00 12.00 49.60 34.50 0.38 — — — — — 106<br />

Approx.<br />

Ship<br />

Wt Lbs<br />

Reference<br />

Drawing<br />

17 CONTROL<br />

PRODUCTS<br />

Note: Dimensions are in inches.<br />

a G designates mounting screw size.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-151


H<br />

I<br />

J<br />

Pump Control Panels<br />

Class 87, 88<br />

Revised on 10/31/19<br />

Dimensions<br />

Outline Drawings<br />

F<br />

Figure 1<br />

F<br />

B<br />

E<br />

Figure 2<br />

5.000<br />

C<br />

Figure 3<br />

C<br />

F<br />

B<br />

Opening for<br />

Conduit Hub<br />

Size "P"<br />

C<br />

A D G<br />

B<br />

H<br />

C<br />

K<br />

Mounting Hole<br />

for 1/4" screw<br />

L<br />

D<br />

A<br />

Handle<br />

(Optional)<br />

F<br />

E<br />

B<br />

Figure 4<br />

A<br />

D G<br />

A<br />

B<br />

H<br />

C<br />

K<br />

L<br />

Handle<br />

(Optional)<br />

NEMA & General<br />

Purpose Control<br />

L M L N<br />

Mounting Holes<br />

For 5/16" Hardware<br />

F<br />

E<br />

J<br />

(4) .687 Dia Holes<br />

D<br />

G<br />

A<br />

K<br />

J<br />

(4) .687 Dia Holes<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Open air contacts<br />

Size<br />

Fig.<br />

Outline Dimensions Mounting Dimensions Conduit Knockout Hub Reference<br />

Drawing<br />

F<br />

A B C D E F G H I J K L M<br />

E<br />

NG<br />

P<br />

1–2 1/2 1 28.50 20.00 8.06 24.00 — 10.00 27.00 5.50 8.50 11.50 — 0.5 – 0.75 1.25 – 1 0.75 – 1 1.50<br />

3 – 4 1 40.50 24.00 8.09 36.00 — 12.00 39.00 8.44 11.94 15.44 — 1.97 – 2.47 0.88 – 1.13 — 2.50<br />

5 2 72.16 20.00 10.00 71.00 16.00 2.13 70.91 — — — — — — — —<br />

6 2 60.00 38.00 16.00 61.60 36.50 0.75 — — — — — — — —<br />

Vacuum contacts<br />

Outline Dimensions Mounting Dimensions Conduit Knockout Hub Reference<br />

Size Fig. A B C D E F G H I J K L M N P Drawing<br />

4 2 55.97 24.38 9.69 54.81 20.25 2.13 54.72 26.19 — — 27.44 — — — —<br />

5 2 72.16 20.00 10.00 71.00 16.00 2.13 70.91 — — — — — — — —<br />

6 2 60.00 38.00 16.00 61.60 36.50 0.75 — — — — — — — —<br />

D<br />

Reduced voltage<br />

Size<br />

AutoTransformer Part Winding & Wye Delta<br />

Outline Dimensions<br />

Disc. & MCP Type Disc. Type MCP Type Fig. A B C D E<br />

2-2 1/2 1–2 1–2 1/2 3 42.00 32.00 12.00 43.60 30.50<br />

3-3 1/2 2 1/2–3 1/2 3–3 1/2 3 48.00 38.00 12.00 49.60 36.50<br />

4 4 4 3 60.00 38.00 16.00 61.60 36.50<br />

5, 6 5, 6 5, 6 4 90.00 30.00 20.00 16.00 24.44<br />

Reference<br />

Drawing<br />

Note: Dimensions are in inches.<br />

All enclosures are Type 3R<br />

17-152<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Lighting Contactors<br />

Enclosed Contactors, Class LC and LE<br />

Revised on 03/31/20<br />

Dimensions<br />

Figure 1 Figure 2 Figure 3<br />

Class LC and LE Non-combo<br />

Enclosure<br />

Type Contactor Rating Fig.<br />

1<br />

without<br />

CPT<br />

1<br />

with<br />

CPT<br />

3/3R/4/12<br />

without<br />

CPT<br />

4/4X<br />

without<br />

CPT<br />

3/3R/4/12<br />

with<br />

CPT<br />

4/4X<br />

with<br />

CPT<br />

Outline Dimensions Mounting a Conduit Size Reference<br />

A B C D E K1 K2 K3 K4 K5 Drawing<br />

LE 20/30A 3-4P 1 10.97 6.41 5.03 8.22 4.62 0.5 0.50 – 0.75 0.75 – 1 — —<br />

LC 30A 2-12P, LE 60A 3P 1 13.53 7.97 6.38 10.25 6 0.50 – 0.75 0.75 – 1 1 – 1.25 — —<br />

LE 30/60A 6-12P, LE 100A 3P 1 19.12 11.38 7.69 15.62 8.25 0.50 – 0.75 1 – 1.25 1.5 – 2 — —<br />

LE 200-400A 3P 2 26 17.62 12.5 25.19 15.5 0.50 – 0.75 1.25 – 1.5 1.25 – 1.5 — —<br />

LC 30A 2-12P, LE 20A 3-4P,<br />

LE 30A 3-9P, LE 60A 3-9P, 1 19.12 11.38 7.69 15.62 8.25 0.50 – 0.75 1 – 1.25 1.5 – 2 — —<br />

LE 100A 3P<br />

LE 30/60A 12P 1 24.88 13.38 8.12 21.75 9 0.50 – 0.75 1.25 – 1.5 2 – 2.5 — —<br />

LE 200-400A 3P 2 26 17.62 12.5 25.19 15.5 — 1.25 – 1.5 1.25 – 1.5 — —<br />

LE 20A 3-4P, LE 30/60A 3-9P,<br />

LC 30A 2-12P<br />

2 16 13.25 6.12 15.25 11 — — — — —<br />

LE 30/60A 12P 2 26 13.12 7.56 25.25 10 — — — — —<br />

LE 100A 3P 2 26 13.12 7.56 25.25 10 — — — — —<br />

LE 200-400A 3P 2 26 17.62 12.5 25.19 15.5 — — — — —<br />

LE 20A 3-4P, LE 30/60A<br />

3-9P,LC 30A 2-12P<br />

2 16 14 6.02 16.75 12 — — — — —<br />

LE 30/60A, 12P 2 24 16 8.76 22.5 14.5 — — — — —<br />

LE 100A 3P 2 24 16 8.76 22.5 14.5 — — — — —<br />

LE 200-400A,3P 2 24 20 10 22.5 18.5 — — — — —<br />

LE 20A 3-4P, LE 30/60A<br />

3-9P,LC 30A 2-12P<br />

2 16 13.25 6.12 15.25 11 — — — — —<br />

LE 30/60A, 12P 2 26 13.12 7.56 25.25 10 — — — — —<br />

LE 100A 3P 2 26 13.12 7.56 25.25 10 — — — — —<br />

LE 200-400A,3P 2 26 17.62 12.5 25.19 15.5 — — — — —<br />

LE 20A 3-4P, LE 30/60A<br />

3-9P,LC 30A 2-12P<br />

2 16 14 6.02 16.75 12 — — — — —<br />

LE 30/60A, 12P 2 24 16 8.76 22.5 14.5 — — — — —<br />

LE 100A 3P 2 24 16 8.76 22.5 14.5 — — — — —<br />

LE 200-400A,3P 2 24 20 10 22.5 18.5 — — — — —<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Class LE Combo<br />

Enclosure<br />

Type<br />

1, 12/3R &<br />

4/4X with &<br />

without CPT<br />

Type<br />

Fusible and<br />

Non-fusible Disconnect<br />

Contactor<br />

Outline Dimensions<br />

Rating Fig. A B C<br />

20–60A 3 24 11 8<br />

100A 3 24 20 8<br />

200A 3 46 20 10<br />

300A 3 76 22 13<br />

Circuit Breaker 20–100A 3 24 11 8<br />

Reference<br />

Drawing<br />

Note: Dimensions are in inches. a Mounting screw G size is 0.25".<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-153


Lighting Contactors<br />

Enclosed Contactors, Class CLM, CM<br />

Revised on 03/31/20<br />

Dimensions<br />

Figure 1 Figure 2 Figure 3<br />

Class CLM Non-combo<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Enclosure<br />

Type<br />

1<br />

without<br />

CPT<br />

1<br />

with CPT<br />

3/3R/4/12<br />

without<br />

CPT<br />

3/3R/4/12<br />

with CPT<br />

4/4X<br />

without<br />

CPT<br />

4/4X<br />

with CPT<br />

Contactor Rating<br />

(Class CLM)<br />

Fig.<br />

Outline Dimensions Mounting a Conduit Size Reference<br />

A B C D E K1 K2 K3 K4 K5 Drawing<br />

30–60A (2-5p) 1 10.97 6.41 5.03 8.22 4.62 0.5 0.50 – 0.75 0.75 – 1 — —<br />

20A (2–12p) 1 13.53 7.97 6.38 10.25 6.00 0.50 – 0.75 0.75 – 1 1 – 1.25 — —<br />

30–60A (6-12p) 2 16.00 17.12 7.62 15.25 14.00 0.50 – 0.75 1.25 – 1.5 1.25 – 1.5 — —<br />

100A (2-5p) 1 19.12 11.38 7.69 15.62 8.25 0.50 – 0.75 1 – 1.25 1.5 – 2 — —<br />

200A (2-5p) 1 24.88 13.38 8.12 21.75 9.00 0.50 – 0.75 1.25 – 1.5 2.5 — —<br />

300–400A (2-5p) 2 48.00 20.00 12.50 45.19 10.00 2.00 – 2.50 1.25 – 1.5 0.5 – 0.75 1.25 – 1.5 2 – 2.5<br />

20A (2–12p), 30A (2–5p) 1 19.12 11.38 7.69 15.62 8.25 0.50 – 0.75 1 – 1.25 1.5 – 2 — —<br />

30–60A (6–12p) 2 16.00 17.12 7.62 15.25 14.00 0.50 – 0.75 1.25 – 1.5 1.25 – 1.5 — —<br />

100-200A (2-5p) 2 26.00 17.62 12.50 25.19 15.50 — 1.25 – 1.5 1.25 – 1.5 — —<br />

300–400A (2-5p) 2 48.00 20.00 12.50 45.19 10.00 2.00-2.50 1.25 – 1.5 0.5 – 0.75 1.25 – 1.5 2 – 2.5<br />

20A (2–12p), 30A (2–12p),<br />

60A (2 - 10p)<br />

2 16.00 13.25 6.12 15.25 11.00 — — — — —<br />

100A (2-5p) 2 16.00 13.00 9.50 15.12 11.00 — — — — —<br />

60A (12p) 2 19.00 22.00 8.00 — — — — — — —<br />

200A (2-5p) 2 26.00 17.62 12.50 23.19 15.50 — — — — —<br />

300A -400A (3p) 2 48.00 20.00 12.50 49.00 10.00 — — — — —<br />

20A (2-12p), 30A (2-5p) 2 16.00 13.25 6.12 15.25 11.00 — — — — —<br />

30A (6-12p) 2 16.00 17.12 7.62 15.25 14.00 — — — — —<br />

60-100A (2-5p) 2 16.00 13.00 9.50 15.12 11.00 — — — — —<br />

60A (6-12p) 2 19.00 22.00 8.00 — — — — — — —<br />

200A (3p) 2 26.00 17.62 12.50 25.19 15.50 — — — — —<br />

300–400A (3p) 2 48.00 20.00 12.50 49.00 10.00 — — — — —<br />

20A (2–12p), 30A (2–12p),<br />

60A (2 - 10p)<br />

2 16.00 14.00 6.02 16.75 12.00 — — — — —<br />

100A (2-5p) 2 16.00 16.00 10.00 14.50 14.50 — — — — —<br />

60A (12p) 2 19.00 22.00 8.00 — — — — — — —<br />

200A (2-5p) 2 24.00 20.00 10.00 22.50 18.50 — — — — —<br />

300A -400A (3p) 2 48.00 20.00 12.50 49.00 10.00 — — — — —<br />

20A (2-12p), 30A (2-5p) 2 16.00 14.00 6.02 16.75 12.00 — — — — —<br />

30A (6-12p) 2 16.00 20.00 8.00 14.50 18.50 — — — — —<br />

60-100A (2-5p) 2 16.00 16.00 10.00 14.50 14.50 — — — — —<br />

60A (6-12p) 2 24.00 20.00 8.00 22.50 18.50 — — — — —<br />

200A (3p) 2 24.00 20.00 10.00 22.50 18.50 — — — — —<br />

300–400A (3p) 2 48.00 20.00 12.50 49.00 10.00 — — — — —<br />

Class CM Combo<br />

Enclosure<br />

Type<br />

1, 12/3R &<br />

4/4X with &<br />

without CPT<br />

Type<br />

Fusible and<br />

Non-fusible Disconnect<br />

Contactor Outline Dimensions Reference<br />

Rating Fig. A B C<br />

Drawing<br />

20–60A 3 24 11 8<br />

100A 3 24 20 8<br />

200A 3 46 20 10<br />

300A 3 76 22 13<br />

Circuit Breaker 20–100A 3 24 11 8<br />

Note: Dimensions are in inches. a Mounting screw G size is 0.25".<br />

17-154<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Manual Control<br />

Class 11 - 3RV, SMF, MMS<br />

Wiring Diagrams<br />

Class 11 - 3RV<br />

Signaling Contact<br />

for Class 11 - 3RV<br />

Typical Wiring Diagrams—Class SMF<br />

3RV1921-1M<br />

Typical Wiring Diagrams—MMS<br />

AC Reversing Manual Starter and<br />

Manual Motor Starting Switches<br />

AC 2-Speed Manual Motor Starting Switches<br />

NEMA & General<br />

Purpose Control<br />

FWD<br />

REV<br />

L1<br />

L2<br />

FWD<br />

(L.H. UNIT)<br />

REV<br />

(R.H. UNIT)<br />

HIGH<br />

LOW<br />

L1<br />

L2<br />

HIGH<br />

LOW<br />

L1 L2 L3<br />

T1<br />

T3<br />

COM<br />

FWD<br />

REV<br />

Motor<br />

L1<br />

L3<br />

T3<br />

T1<br />

L1<br />

L3<br />

REVERSING<br />

SINGLE PHASE<br />

3-LEAD<br />

REPULSION-INDUCTION<br />

MOTOR<br />

Pilot Light<br />

(if used)<br />

T1<br />

T2<br />

T3<br />

L1<br />

L2<br />

L3<br />

T1<br />

T2<br />

T3<br />

L1<br />

L2<br />

L3<br />

HIGH<br />

LOW<br />

COM<br />

Motor<br />

T1<br />

T3<br />

L1<br />

L3<br />

T1 L1<br />

T3 L3<br />

2-SPEED<br />

2-WINDING<br />

SINGLE PHASE<br />

MOTOR<br />

Pilot Lights<br />

(if used)<br />

T1 L1<br />

T2 L2<br />

T3 L3<br />

T11<br />

T12<br />

T13<br />

T1<br />

T2<br />

T3<br />

Motor<br />

T1<br />

T2<br />

T3<br />

L1<br />

L2<br />

L3<br />

Pilot Lights<br />

(if used)<br />

2-SPEED<br />

2-WINDING WYE CONNECTED<br />

3- PHASE<br />

MOTOR<br />

17 CONTROL<br />

PRODUCTS<br />

Reversing Manual Motor<br />

Starting Switch 2-Pole, 1-Phase<br />

Reversing Manual Starter<br />

3-Pole, 3-Phase<br />

2-Pole, 1-Phase with<br />

Pilot Lights<br />

3-Pole, 3-Phase<br />

3-Pole Reversing Switches<br />

THREE PHASE MOTOR<br />

LINE AND L.H. R.H.<br />

MOTOR LEADS UNIT UNIT<br />

L1 to<br />

L1<br />

Line L2 to<br />

L2 _<br />

L3 to<br />

L3<br />

T1 to T1<br />

Meter T2 to T2 _<br />

T3 to T3<br />

_<br />

Pilot Light<br />

Leads to<br />

T1 T2 T3<br />

T1<br />

T3<br />

SINGLE PHASE CAPACITOR<br />

OR SPLIT PHASE MOTOR<br />

LINE AND<br />

MOTOR LEADS<br />

Line<br />

Meter<br />

L1 to<br />

L2 to<br />

T1 to<br />

T4 to<br />

T5 to<br />

T8 to<br />

Furnish Jumper<br />

Pilot Light<br />

Leads to<br />

L.H.<br />

UNIT<br />

_<br />

T1<br />

T3<br />

L1<br />

T2<br />

L3 to<br />

_<br />

R.H.<br />

UNIT<br />

L1<br />

L2<br />

_<br />

T2<br />

T1<br />

T3<br />

SINGLE PHASE 4-LEAD<br />

REPULSION - INDUCTION MOTOR<br />

LINE AND<br />

MOTOR LEADS<br />

Line<br />

Meter<br />

L1 to<br />

L2 to<br />

T1 to<br />

T4 to<br />

T5 to<br />

T8 to<br />

Furnish Jumper<br />

Pilot Light<br />

Leads to<br />

L.H.<br />

UNIT<br />

_<br />

T2<br />

L3<br />

T3<br />

T1<br />

L3 to<br />

_<br />

R.H.<br />

UNIT<br />

L1<br />

L2<br />

_<br />

T2<br />

L1<br />

T2<br />

T8 T4<br />

T1 T5<br />

T8 T1 T5 T4<br />

Motor<br />

RUN<br />

START<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-155


X1<br />

X1<br />

X1<br />

X1<br />

Heavy Duty Motor Starters<br />

Class 14<br />

Revised on 03/31/20<br />

Wiring Diagrams<br />

3-Phase and Single Phase Magnetic Starters<br />

WIRING DIAGRAM<br />

Three Phase Magnetic Starter, Size 00–4 NEMA 00 - 4<br />

TO SUPPLY<br />

L1 L2 L3<br />

TO PILOT<br />

CONTROL DEVICE<br />

Single Phase Magnetic Starter ab<br />

WIRING DIAGRAM<br />

IF PROVIDED<br />

TO SUPPLY<br />

L1 L2<br />

NEMA 00 - 4<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

IF PROVIDED<br />

A<br />

WIRING DIAGRAM 3 PHASE MAGNETIC STARTER<br />

Three Phase Magnetic Starter with DC Coil, Sizes NEMA 00–400 - 4<br />

SIZE 00 - 4<br />

IF PROVIDED<br />

3<br />

2<br />

TO SUPPLY<br />

TO PILOT L1 L2 L3<br />

CONTROL DEVICE<br />

3<br />

2<br />

V<br />

V<br />

1<br />

1<br />

T1<br />

M<br />

M<br />

T1<br />

W<br />

T2<br />

MOTOR<br />

W<br />

T2<br />

MOTOR<br />

T3<br />

ESP200<br />

95 96 97 98<br />

A3+A4-<br />

T3<br />

ESP200<br />

95 96 97<br />

A3+ A4-<br />

98<br />

B<br />

CONTROL FUSES<br />

(OPTIONAL)<br />

B 1 96 CONTROL<br />

TRANSFORMER<br />

(OPTIONAL)<br />

LATE<br />

BREAK<br />

SEC FUSE<br />

CONTACT<br />

XF<br />

H4<br />

X1<br />

C H2<br />

SEC<br />

H3<br />

X2<br />

H1<br />

MAY BE<br />

GROUNDED BY<br />

CUSTOMER<br />

THREE PHASE MAGNETIC STARTER<br />

WITH D.C. COIL<br />

1<br />

CONTROL FUSES<br />

(OPTIONAL)<br />

96 CONTROL<br />

TRANSFORMER<br />

(OPTIONAL)<br />

SEC FUSE<br />

XF<br />

H4<br />

X1<br />

C H2<br />

SEC<br />

H3<br />

X2<br />

H1<br />

MAY BE<br />

GROUNDED BY<br />

CUSTOMER<br />

SINGLE PHASE MAGNETIC STARTER<br />

Solid State Overload 3-Phase SIZE 00 Sizes - 45-8<br />

POWER WIRING:<br />

USE 75°C COPPER WIRE ONLY.<br />

SIZE<br />

5<br />

6<br />

7<br />

8<br />

A<br />

CT RATIO<br />

300:5<br />

600:5<br />

750:5<br />

1200:5<br />

3<br />

2<br />

CONTACTOR<br />

CURRENT<br />

TRANSFORMER<br />

(WHEN USED, SEE TABLE)<br />

NOTES:<br />

A: 2CT IS LOCATED ON THE LINE SIDE<br />

OF CONTACTOR ON SIZE 7 STARTERS ONLY.<br />

V<br />

T1<br />

1<br />

3<br />

M<br />

T1 T2<br />

MOTOR<br />

2<br />

A "<br />

"<br />

INCOMING LINE<br />

A B C<br />

CIRCUIT<br />

PROTECTIVE<br />

DEVICE<br />

2CT<br />

L1/1 L2 L3<br />

A1<br />

T1<br />

(IF USED)<br />

M<br />

W<br />

T2<br />

A1 ESP200 A3<br />

95 96 97 98<br />

A3+ A4-<br />

LOAD<br />

A2<br />

1CT 2CT 3CT<br />

T2<br />

B<br />

T3<br />

1<br />

NOTE A<br />

B "<br />

C<br />

"<br />

"<br />

"<br />

"<br />

C<br />

CONTROL FUSES<br />

(OPTIONAL)<br />

96<br />

CONTROL<br />

TRANSFORMER<br />

(OPTIONAL)<br />

SEC FUSE<br />

XF<br />

H4<br />

X1<br />

H2<br />

H3<br />

H1<br />

MAY BE<br />

GROUNDED BY<br />

CUSTOMER<br />

REMOVE WIRE C " IF THE CONTACTOR<br />

COIL IS TO OPERATE ON A VOLTAGE<br />

OTHER THAN LINE VOLTAGE OR ON A<br />

SEPARATE CONTROL SOURCE.<br />

95<br />

96<br />

SEC<br />

X2<br />

RELAY<br />

(IF USED)<br />

O.L.<br />

a Warning: The ESP200 Starter and Single Phase<br />

Motor must be wired as shown above. For L1, L2<br />

do not use the middle terminal or hole.<br />

b Full Load Amps (FLA): Adjustment of the ESP200<br />

solid state overload relay accommodates the single<br />

phase motor.<br />

17-156<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Combination Heavy Duty Starters<br />

Class 17, 18<br />

Wiring Diagrams<br />

3-Phase<br />

Size 00–4 a<br />

WIRING DIAGRAM<br />

TO SUPPLY<br />

TO PILOT L1 L2 L3<br />

CONTROL DEVICE<br />

NEMA 00 - 4<br />

IF PROVIDED<br />

A<br />

3<br />

2<br />

1<br />

V<br />

W<br />

M<br />

T1 T2 T3<br />

ESP200<br />

95 96 97<br />

A3+ A4-<br />

98<br />

B<br />

1<br />

CONTROL FUSES<br />

(OPTIONAL)<br />

96 CONTROL<br />

TRANSFORMER<br />

(OPTIONAL)<br />

SEC FUSE<br />

XF<br />

H4<br />

X1<br />

C H2<br />

SEC<br />

H3<br />

X2<br />

H1<br />

MOTOR<br />

MAY BE<br />

GROUNDED BY<br />

CUSTOMER<br />

3 PHASE MAGNETIC STARTER<br />

SIZE 00 - 4<br />

Size 5–8 b<br />

SIZE<br />

CT RATIO<br />

NEMA & General<br />

Purpose Control<br />

5 300:5<br />

“C”<br />

6 600:5<br />

7 750:5<br />

8 1200:5<br />

17 CONTROL<br />

PRODUCTS<br />

a Remove wire “C” if control transformer is used. For<br />

separate control voltage source, remove jumpers<br />

“A” and “B” and connect source to control fuse line<br />

terminals.<br />

b Remove wire “C” if the contactor coil is to operate<br />

on a voltage other than line voltage or in a separate<br />

control source.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-157


Reversing Heavy Duty Starters<br />

Class 22<br />

Wiring Diagrams<br />

3-Phase Solid State Overload<br />

3-Phase Reversing Magnetic Starter<br />

Sizes 00–1 WIRING 3 ⁄4 DIAGRAM<br />

NEMA 00 - 1 3 4<br />

3-Phase Reversing Magnetic Starter<br />

Sizes 2–4<br />

WIRING DIAGRAM<br />

NEMA 2 - 4<br />

TO SUPPLY<br />

L1 L2 L3<br />

TO SUPPLY<br />

L1 L2 L3<br />

3<br />

2<br />

1<br />

5<br />

V W<br />

FOR<br />

7 6 V<br />

REV<br />

W<br />

1<br />

4<br />

ESP200<br />

95 96 97 98<br />

A3+A4-<br />

A<br />

B<br />

T1 T2 T3<br />

T2<br />

T1 T3<br />

MOTOR<br />

Solid State Overload<br />

3 PHASE REVERSING<br />

Sizes 5–6<br />

MAGNETIC STARTER<br />

TO SUPPLY<br />

L1 L2 L3<br />

CONTROL FUSES<br />

(OPTIONAL)<br />

96 CONTROL<br />

TRANSFORMER<br />

(OPTIONAL)<br />

SEC FUSE<br />

XF<br />

H4<br />

X1<br />

C H2<br />

SEC<br />

H3<br />

X2<br />

H1<br />

MAY BE<br />

GROUNDED BY<br />

CUSTOMER<br />

V FOR W<br />

T1 T2 T3<br />

ESP200<br />

95 96 97 98<br />

A3+A4-<br />

MOTOR<br />

3<br />

2<br />

7<br />

A<br />

5<br />

4<br />

6<br />

V<br />

REV<br />

3 PHASE REVERSING<br />

MAGNETIC STARTER<br />

B<br />

W<br />

1<br />

1<br />

96<br />

CONTROL FUSES<br />

(OPTIONAL)<br />

CONTROL<br />

TRANSFORMER<br />

(OPTIONAL)<br />

SEC FUSE<br />

XF<br />

H4<br />

X1<br />

C H2<br />

SEC<br />

H3<br />

X2<br />

H1<br />

MAY BE<br />

GROUNDED BY<br />

CUSTOMER<br />

NEMA & General<br />

Purpose Control<br />

"FWD"<br />

CONTRACTOR<br />

CONTACTOR<br />

MECHANICAL<br />

INTERLOCK<br />

"REV"<br />

CONTACTOR<br />

CURRENT<br />

TRANSFORMER<br />

(SEE TABLE)<br />

O.L.<br />

RELAY<br />

17<br />

CONTROL<br />

PRODUCTS<br />

MOTOR<br />

REMOVE WIRE "C" IF THE CONTACTOR<br />

COIL IS TO OPERATE ON A VOLTAGE<br />

OTHER THAN LINE VOLTAGE OR ON A<br />

SEPARATE CONTROL SOURCE.<br />

3-Phase Reversing Magnetic Starter<br />

with DC Coil, WIRING Sizes DIAGRAM 00–1 3 ⁄4<br />

TO SUPPLY<br />

L1 L2 L3<br />

NEMA 00 - 1 3 4<br />

3-Phase Reversing Magnetic Starter<br />

with DC Coil, Sizes 2–4<br />

TO SUPPLY<br />

L1 L2 L3<br />

WIRING DIAGRAM<br />

NEMA 2 - 4<br />

1<br />

3<br />

5<br />

7<br />

3<br />

V<br />

FOR<br />

W<br />

5<br />

V<br />

REV<br />

W<br />

6<br />

CONTROL FUSES<br />

(OPTIONAL)<br />

V<br />

FOR<br />

W<br />

V<br />

REV<br />

W<br />

17-158<br />

2 T1<br />

T2 T3 4<br />

ESP200<br />

95 96 97 98<br />

A3+A4-<br />

T2<br />

MOTOR<br />

T1 T3<br />

LATE BREAK<br />

3 PHASE REVERSING<br />

MAGNETIC STARTER W/DC COIL<br />

96 CONTROL<br />

TRANSFORMER<br />

(OPTIONAL)<br />

SEC FUSE<br />

XF<br />

H4<br />

X1<br />

MAY BE<br />

GROUNDED BY<br />

CUSTOMER<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

B<br />

1<br />

C<br />

H2<br />

H3<br />

H1<br />

SEC<br />

X2<br />

2<br />

7<br />

ESP200<br />

95 96 97 98<br />

A3+A4-<br />

T1 T2 T3<br />

T1<br />

L.B.<br />

T2<br />

1<br />

T3<br />

MOTOR<br />

CONTROL FUSES<br />

(OPTIONAL)<br />

B<br />

L.B.<br />

96<br />

SEC FUSE<br />

XF<br />

H4<br />

X1<br />

CONTROL<br />

C H2<br />

TRANSFORMER<br />

SEC (OPTIONAL)<br />

H3<br />

X2<br />

H1<br />

MAY BE<br />

GROUNDED BY<br />

CUSTOMER<br />

3 PHASE REVERSING<br />

MAGNETIC STARTER W/DC COIL<br />

4<br />

6


Combination Reversing Heavy Duty Starters<br />

Class 25, 26<br />

Wiring Diagrams<br />

3-Phase<br />

3-Phase Reversing Magnetic Starter<br />

Sizes WIRING 00–1 DIAGRAM 3 ⁄4<br />

TO SUPPLY<br />

L1 L2 L3<br />

NEMA 00 - 1 3 4<br />

TO SUPPLY<br />

L1 L2 L3<br />

3-Phase Reversing Magnetic Starter<br />

Sizes 2–4<br />

WIRING DIAGRAM<br />

NEMA 2 - 4<br />

3<br />

2<br />

V W<br />

FOR<br />

ESP200<br />

95 96 97 98<br />

A3+A4-<br />

T1<br />

T2<br />

T3<br />

T2<br />

T1 T3<br />

MOTOR<br />

7<br />

6<br />

A<br />

"FWD"<br />

CONTRACTOR<br />

CONTACTOR<br />

5<br />

V<br />

REV<br />

W<br />

3 PHASE REVERSING<br />

MAGNETIC STARTER<br />

4<br />

1<br />

B<br />

1<br />

TO SUPPLY<br />

L1 L2 L3<br />

CONTROL FUSES<br />

(OPTIONAL)<br />

96 CONTROL<br />

TRANSFORMER<br />

(OPTIONAL)<br />

SEC FUSE<br />

XF<br />

H4<br />

X1<br />

C H2<br />

SEC<br />

H3<br />

X2<br />

H1<br />

MAY BE<br />

GROUNDED BY<br />

CUSTOMER<br />

Size 5–6<br />

V FOR W<br />

T1 T2 T3<br />

ESP200<br />

95 96 97 98<br />

A3+A4-<br />

MOTOR<br />

3<br />

2<br />

7<br />

A<br />

5<br />

4<br />

6<br />

V<br />

"REV"<br />

CONTACTOR<br />

REV<br />

3 PHASE REVERSING<br />

MAGNETIC STARTER<br />

B<br />

W<br />

1<br />

1<br />

96<br />

CONTROL FUSES<br />

(OPTIONAL)<br />

CONTROL<br />

TRANSFORMER<br />

(OPTIONAL)<br />

SEC FUSE<br />

XF<br />

H4<br />

X1<br />

C H2<br />

SEC<br />

H3<br />

X2<br />

H1<br />

MAY BE<br />

GROUNDED BY<br />

CUSTOMER<br />

NEMA & General<br />

Purpose Control<br />

MECHANICAL<br />

INTERLOCK<br />

17 CONTROL<br />

PRODUCTS<br />

CURRENT<br />

TRANSFORMER<br />

(SEE TABLE)<br />

O.L.<br />

RELAY<br />

REMOVE WIRE "C" IF THE CONTACTOR<br />

COIL IS TO OPERATE ON A VOLTAGE<br />

OTHER THAN LINE VOLTAGE OR ON A<br />

SEPARATE CONTROL SOURCE.<br />

MOTOR<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-159


Two Speed Heavy Duty Starters<br />

Class 30 & 32 Non-Combination and Combination Starters<br />

Wiring Diagrams<br />

1 Winding Constant Horsepower Size 0–1 3 /4<br />

TO SUPPLY<br />

L1 L2 L3<br />

DISCONNECT or<br />

CIRCUIT BREAKER<br />

HIGH<br />

A<br />

POSITION<br />

LOW SPEED<br />

HIGH SPEED<br />

L1<br />

T1 T2<br />

T6 T4<br />

HIGH<br />

HIGH<br />

LOW<br />

OL<br />

HIGH<br />

OL<br />

LOW LOW<br />

LOW<br />

ALL OL'S<br />

96 95<br />

L2 L3<br />

T3<br />

T5<br />

TOGETHER<br />

T4 T5 T6<br />

ELEMENTARY DIAGRAM<br />

T6<br />

LOW<br />

T4<br />

LOW<br />

T5<br />

2<br />

4<br />

T1<br />

T5<br />

T6<br />

T2<br />

T2<br />

CONSTANT HORSEPOWER<br />

MOTOR<br />

T3<br />

HIGH<br />

LOW<br />

3<br />

5<br />

T3<br />

T4<br />

6 LOW<br />

7 HIGH<br />

T1<br />

HIGH 8<br />

LOW<br />

6<br />

5<br />

4<br />

5 6<br />

4<br />

TO SUPPLY<br />

L1 L2 L3<br />

L1 L2 L3<br />

DISCONNECT or<br />

CIRCUIT BREAKER<br />

V<br />

V LOW W<br />

T1 T2 T3<br />

T6 T4 T5<br />

T1 T2 T3<br />

T6 T4 T5<br />

T1<br />

T2T1<br />

T3T2<br />

T4T3<br />

T5T4<br />

T6T5<br />

T6<br />

7 7 3<br />

MOTOR<br />

M<br />

WIRING DIAGRAM<br />

TO SUPPLY<br />

NEMA 00 - 1 3 4<br />

LOW W<br />

A<br />

3<br />

8 1<br />

V HIGH W<br />

2<br />

2<br />

8<br />

V<br />

HIGH W<br />

C<br />

ESP200<br />

95 96 97 98<br />

OVERLOAD A3+ RELAY A4-<br />

95 96<br />

ESP200<br />

95 96 97 98<br />

OVERLOAD A3+ A4- RELAY<br />

95 96<br />

B<br />

A<br />

CONTROL FUSES<br />

(OPTIONAL)<br />

B 1 96<br />

CONTROL<br />

TRANSFORMER<br />

(OPTIONAL)<br />

1 96 CONTROL FUSES SEC FUSE<br />

(OPTIONAL) XF<br />

H4<br />

X1<br />

C H2<br />

CONTROL TRANSFORMER<br />

(OPTIONAL)<br />

SEC<br />

SEC FUSE H3<br />

XF<br />

X2<br />

H4 X1H1<br />

H2<br />

SEC<br />

MAY BE<br />

H3 GROUNDED BY<br />

CUSTOMER<br />

X2<br />

H1<br />

2 SPEED 3 PHASE 1 WINDING<br />

CONSTANT HORSEPOWER<br />

1 Winding Constant Horsepower Size 2–4<br />

TO SUPPLY<br />

L1 L2 L3<br />

WIRING DIAGRAM<br />

NEMA 2 - 4<br />

NEMA & General<br />

Purpose Control<br />

5<br />

3<br />

1<br />

6<br />

VLOWW<br />

VHIGHW<br />

4<br />

2<br />

6 7<br />

ESP200<br />

A<br />

ESP200<br />

95 96 97 98<br />

95 96 97 98<br />

A3+ A4-<br />

A3+ A4-<br />

T1 T2 T3<br />

V L W<br />

B<br />

T6 T4 T5<br />

1<br />

CONTROL FUSES<br />

(OPTIONAL)<br />

96<br />

CONTROL<br />

TRANSFORMER<br />

(OPTIONAL)<br />

SEC FUSE<br />

XF<br />

H4<br />

X1<br />

C<br />

H2<br />

H3<br />

H1<br />

SEC<br />

X2<br />

17<br />

T1<br />

T2<br />

T3<br />

T4<br />

T5<br />

T6<br />

MOTOR<br />

MAY BE<br />

GROUNDED BY<br />

CUSTOMER<br />

CONTROL<br />

PRODUCTS<br />

1 Winding Constant or Variable Torque Size 0–1 3 /4<br />

2 SPEED 3 PHASE 1 WINDING<br />

CONSTANT HORSEPOWER<br />

TO SUPPLY ELEMENTARY DIAGRAM<br />

L1 L2 L3<br />

DISCONNECT or<br />

CIRCUIT BREAKER<br />

T4<br />

LOW<br />

T1<br />

LOW<br />

OL HIGH<br />

LOW<br />

T2<br />

T3 T1<br />

LOW<br />

HIGH T5<br />

T2<br />

T6<br />

T3 CONSTANT TORQUE MOTOR<br />

HIGH<br />

T4<br />

T6<br />

OL<br />

HIGH HIGH<br />

T4<br />

T1<br />

T3<br />

A<br />

HIGH<br />

T5 T5 T2 T6<br />

ALL OL'S<br />

VARIABLE TORQUE MOTOR<br />

96 95 2 3 HIGH 6<br />

8<br />

LOW<br />

LOW<br />

POSITION L1 L2 L3 TOGETHER<br />

LOW SPEED T1 T2 T3<br />

HIGH SPEED T6 T4 T5 T1 T2 T3<br />

4<br />

HIGH<br />

5<br />

LOW<br />

7<br />

HIGH<br />

6<br />

5<br />

4<br />

5 6<br />

4<br />

TO SUPPLY<br />

TO SUPPLY<br />

L1 L2 L3<br />

L1 L2 L3<br />

DISCONNECT or<br />

CIRCUIT BREAKER<br />

WIRING WIRING DIAGRAM DIAGRAM<br />

3<br />

8 1<br />

V HIGH W V LOW W<br />

8<br />

B<br />

1 96<br />

7 3<br />

V HIGH W<br />

7 V LOW W<br />

CONTROL<br />

TRANSFORMER<br />

(OPTIONAL)<br />

2<br />

C 1 96<br />

CONTROL<br />

2<br />

SEC FUSESFUSE<br />

(OPTIONAL) XF<br />

ESP200<br />

ESP200<br />

H4<br />

X1<br />

OVERLOAD 95 96 RELAY 97 98 A<br />

OVERLOAD 95 96 RELAY 97 98<br />

95 A3+ A4- 96<br />

95 A3+ A4- 96<br />

CONTROL C H2TRANSFORMER<br />

(OPTIONAL) SEC<br />

T6<br />

T6 T4 T4 T5 T5<br />

T1 T1T2<br />

T2 T3<br />

T3<br />

SEC FUSE<br />

XF<br />

H3<br />

H4<br />

X2<br />

X1<br />

H1<br />

H2<br />

T1<br />

T1<br />

SEC<br />

T2<br />

T3 T2<br />

H3 MAY BE<br />

T4 T3 MOTOR<br />

GROUNDED X2 BY<br />

T5 T4 M<br />

H1<br />

T6 T5<br />

CUSTOMER<br />

T6<br />

B<br />

A<br />

NEMA 00 - 1 3 4<br />

CONTROL FUSES<br />

(OPTIONAL)<br />

2 SPEED 3 PHASE 1 WINDING<br />

CONSTANT OR VARIABLE TORQUE<br />

Note: For separate control voltage source, remove jumpers “A” and “B” and connect source to control fuse terminal. Remove jumper “C” if control transformer is used.<br />

17-160<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Two Speed Heavy Duty Starters<br />

Class 30 & 32 Non-Combination and Combination Starters<br />

Wiring Diagrams<br />

1 Winding Constant or Variable Torque Size 2–4<br />

TO SUPPLY<br />

L1 L2 L3<br />

WIRING DIAGRAM<br />

NEMA 2 - 4<br />

5<br />

1<br />

3<br />

CONTROL FUSES<br />

(OPTIONAL)<br />

VHIGHW<br />

V LOWW<br />

4<br />

6 7<br />

A<br />

ESP200<br />

ESP200<br />

95 96 97 98<br />

95 96 97 98<br />

A3+ A4-<br />

A3+ A4-<br />

T6 T4 T5<br />

2<br />

V H W<br />

T1 T2<br />

B<br />

T3<br />

1<br />

96<br />

CONTROL<br />

TRANSFORMER<br />

(OPTIONAL)<br />

C<br />

SEC FUSE<br />

XF<br />

H4<br />

X1<br />

H2<br />

H3<br />

H1<br />

SEC<br />

X2<br />

T1<br />

T2<br />

T3<br />

T4<br />

T5<br />

T6<br />

MOTOR<br />

MAY BE<br />

GROUNDED BY<br />

CUSTOMER<br />

D68784002<br />

2 SPEED 3 PHASE 1 WINDING<br />

CONSTANT OR VARIABLE TORQUE<br />

2 Winding Constant Horsepower & 2 Winding Constant or Variable Torque Size 0–4<br />

NEMA & General<br />

Purpose Control<br />

TO SUPPLY<br />

L1 L2 L3<br />

DISCONNECT or<br />

CIRCUIT BREAKER<br />

LOW<br />

LOW<br />

LOW<br />

HIGH<br />

HIGH<br />

HIGH<br />

A<br />

POSITION L1 L2 L3<br />

LOW SPEED T1 T2 T3<br />

HIGH SPEED T11 T12 T13<br />

ELEMENTARY DIAGRAM<br />

OL<br />

LOW<br />

OL<br />

HIGH<br />

ALL OL'S<br />

96 95<br />

4<br />

2<br />

T1<br />

T2<br />

T3<br />

T11<br />

T12<br />

T13<br />

HIGH<br />

LOW<br />

T1<br />

T2<br />

T12<br />

T3<br />

T11<br />

T13<br />

TWO WINDING MOTOR<br />

5<br />

3<br />

LOW<br />

HIGH<br />

6<br />

7<br />

HIGH<br />

LOW<br />

8<br />

NEMA 2 - 4<br />

TO SUPPLY<br />

WIRING DIAGRAM<br />

L1 L2 L3<br />

TO SUPPLY<br />

WIRING DIAGRAM<br />

L1 L2 L3<br />

DISCONNECT or<br />

CIRCUIT BREAKER<br />

3 5<br />

1<br />

B A CONTROL FUSES<br />

8<br />

(OPTIONAL)<br />

V LO W<br />

V HI W<br />

2 4<br />

B<br />

1 96<br />

8<br />

CONTROL<br />

37<br />

5 6<br />

V W<br />

V HIGH W<br />

TRANSFORMER<br />

LOW<br />

(OPTIONAL)<br />

C 1 96<br />

SEC FUSE<br />

CONTROL FUSES<br />

2 6 7 4<br />

XF<br />

(OPTIONAL)<br />

T1 T2 T3<br />

T11 T12 T13<br />

H4<br />

X1<br />

ESP200<br />

ESP200<br />

OVERLOAD 95 96 RELAY 97 98 A<br />

OVERLOAD<br />

95 96<br />

RELAY<br />

97 98<br />

95 96<br />

95 96<br />

CONTROL CTRANSFORMER<br />

H2<br />

A3+ A4-<br />

A3+ A4-<br />

(OPTIONAL) SEC<br />

T1 T2 T3<br />

T11 T12 T13<br />

SEC FUSE<br />

XF<br />

H3<br />

H4 X1<br />

X2<br />

T1<br />

H2<br />

H1<br />

T2<br />

SEC<br />

T1 T3<br />

T2 T11 M<br />

H3<br />

X2<br />

T3 T12<br />

MAY BE<br />

T13<br />

T11 MOTOR<br />

H1 GROUNDED BY<br />

T12<br />

CUSTOMER<br />

T13<br />

17 CONTROL<br />

PRODUCTS<br />

D68786001<br />

2 SPEED 3 PHASE 2 WINDING<br />

SEPARATE WINDING<br />

Note: For separate control voltage source, remove jumpers “A” and “B” and connect source to control fuse terminal. Remove jumper “C” if control transformer is used.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-161


Reduced Voltage Starters & Pump Panels<br />

Class 36, 37, 88<br />

Wiring Diagrams<br />

Part Winding<br />

CONTROL<br />

PRODUCTS<br />

17<br />

NEMA & General<br />

Purpose Control<br />

EMT<br />

17-162<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


SEK<br />

SES<br />

SAW<br />

LMB<br />

SEK<br />

SES<br />

SAW<br />

LMB<br />

SEK<br />

SES<br />

SAW<br />

LMB<br />

Reduced Voltage Starters & Pump Panels<br />

Class 36, 37, 88<br />

Wiring Diagrams<br />

Auto Transformer<br />

TO SUPPLY<br />

L1 L2 L3<br />

OPTIONAL<br />

DISCONNECT<br />

OR<br />

CIRCUIT BREAKER<br />

L2<br />

OL<br />

1S<br />

1CT<br />

R<br />

L1 L3 2S 1L1 3L1<br />

T1<br />

100%<br />

80%<br />

65%<br />

50%<br />

0%<br />

2L1<br />

OL<br />

2CT<br />

OL<br />

2S<br />

R<br />

2S<br />

1L2<br />

1L3<br />

100%<br />

80%<br />

65%<br />

50%<br />

0%<br />

3L2<br />

1S<br />

2L2<br />

1S<br />

3L3<br />

T2<br />

*<br />

MOTOR<br />

FOR MOTOR<br />

HP SEE<br />

CONTROLLER<br />

NAMEPLATE<br />

3CT<br />

FOR STARTER<br />

SIZES 1-4, 1CT-3CT<br />

ARE NOT USED.<br />

R<br />

100%<br />

80%<br />

65%<br />

50%<br />

0%<br />

2L3<br />

T3<br />

L1<br />

4FU<br />

MR<br />

1S<br />

71 73<br />

74 (A1)<br />

(A2) 75 R 76 MR 72<br />

2S<br />

5FU<br />

L2<br />

2S<br />

CR1<br />

77<br />

(A1)<br />

1S<br />

(A2)<br />

1<br />

TAS 12<br />

L1<br />

2FU<br />

1FU<br />

CR1<br />

H1<br />

X1<br />

78<br />

1S<br />

79<br />

CPT<br />

H4<br />

(A1)<br />

MECH<br />

* INTLK<br />

(A2)<br />

R<br />

3FU<br />

L2<br />

X2<br />

NEMA & General<br />

Purpose Control<br />

JUMPER<br />

NOTE E<br />

1 2<br />

3<br />

CONNECT<br />

VOLTAGE<br />

AS SPECIFIED<br />

PER NAMEPLATE<br />

SUPPLIED AS REQUIRED<br />

3<br />

(A1)<br />

LMB<br />

SAW<br />

SES<br />

SEK<br />

TR<br />

MR<br />

LMB<br />

SAW<br />

SES<br />

SEK<br />

(A2)<br />

4<br />

OL<br />

(95) (96)<br />

X2<br />

2 3<br />

MR<br />

TR<br />

NOTC<br />

6 (A1)<br />

(A2)<br />

CR1<br />

CONNECTIONS FOR OPTIONAL DEVICES<br />

17 CONTROL<br />

PRODUCTS<br />

Note E:<br />

Remove jumper if thermal<br />

protection switch is provided.<br />

START<br />

STOP<br />

1 2 3<br />

1PB 2PB<br />

HAND<br />

OFF AUTO START<br />

1 2 3<br />

*<br />

2PB<br />

SURGE SUPPRESSOR<br />

(A1)<br />

(A1)<br />

CR2<br />

(A2)<br />

(A2)<br />

AUTO<br />

CONTACT<br />

5<br />

1<br />

1SS<br />

*<br />

OFF<br />

HAND AUTO<br />

1<br />

*<br />

3<br />

3 4<br />

ETM<br />

RUN/ON/<br />

RUNNING<br />

3 4<br />

1LT<br />

1<br />

AUTO<br />

CONTACT<br />

5<br />

1SS *<br />

OFF ON<br />

1 3<br />

1SS *<br />

OL OL TRIPPED<br />

1 9 X2<br />

4LT<br />

MR OFF/STOP<br />

1<br />

10 X2<br />

5LT<br />

OPTIONAL DEVICES ARE FURNISHED PER CONTRACT DOCUMENTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-163


Reduced Voltage Starters & Pump Panels<br />

Class 36, 37, 88<br />

Wiring Diagrams<br />

Wye Delta (Open Transition)<br />

CONTROL<br />

PRODUCTS<br />

17<br />

NEMA & General<br />

Purpose Control<br />

17-164<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Reduced Voltage Starters & Pump Panels<br />

Class 36, 37, 88<br />

Wiring Diagrams<br />

Wye Delta (Closed Transition)<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-165


Heavy Duty Contactors and Reversing Contactors<br />

Class 40, 43<br />

Wiring Diagrams<br />

3-Phase Magnetic Contactors and Reversing Contactors<br />

3-Phase Contactors—Size 00–4<br />

3-Phase Reversing Contactors—Size 00–4<br />

3-Phase Contactors—Size 5, 6<br />

3-Phase Reversing Contactors—Size 5, 6<br />

TO SUPPLY<br />

L1 L2 L3<br />

"FWD"<br />

CONTRACTOR<br />

CONTACTOR<br />

"REV"<br />

CONTACTOR<br />

MECHANICAL<br />

NEMA & General<br />

Purpose Control<br />

CURRENT<br />

TRANSFORMER<br />

INTERLOCK<br />

RELAY<br />

REMOVE WIRE "C" IF THE CONTACTOR<br />

COIL IS TO OPERATE ON A VOLTAGE<br />

OTHER THAN LINE VOLTAGE OR ON A<br />

SEPARATE CONTROL SOURCE.<br />

17<br />

LOAD<br />

CONTROL<br />

PRODUCTS<br />

Single Phase Magnetic Contactors and Reversing Contactors<br />

Single Phase Contactors—Size 00–4<br />

Single Phase Reversing Contactors—Size 00–1P<br />

17-166<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Duplex Heavy Duty Controllers<br />

Class 83, 84<br />

Wiring Diagrams<br />

Standard Duplex Pump Panel (92) Duplex Panel w/o alternator (95)<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-167


Duplex Heavy Duty Controllers<br />

Class 83, 84<br />

Wiring Diagrams<br />

Duplex Panel with Relay Alternation (93) Duplex Panel with Lead Pump Transfer Switch (94)<br />

CONTROL<br />

PRODUCTS<br />

17<br />

NEMA & General<br />

Purpose Control<br />

17-168<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Standard & Irrigation Pump Panels<br />

Class 82, 87<br />

Revised on 01/17/17<br />

Wiring Diagrams<br />

Class 82 Pump Panel<br />

TO SUPPLY<br />

L1 L2 L3<br />

DISCONNECT<br />

LEGEND<br />

- FIELD WIRING<br />

- TERMINAL ON COMPONENT<br />

- LOAD\CONTROL TERMINAL BLOCK POINT<br />

LINE<br />

FUSES<br />

1L1<br />

M<br />

2L1<br />

OLR<br />

T1<br />

1L2<br />

2L2<br />

T2<br />

MOTOR<br />

1L3<br />

2L3<br />

T3<br />

OFF<br />

HAND AUTO<br />

START<br />

PB<br />

OLR<br />

M<br />

( A1) (A2) (95) (96)<br />

SS<br />

(14)<br />

M (13)<br />

AUTO AUTO<br />

4 RUN 5 STOP 6<br />

NEMA & General<br />

Purpose Control<br />

REMOVE JUMPER FOR AUTO - STOP<br />

Standard Class 87 Pump Panel<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-169


Duplex Heavy Duty Controllers<br />

Class LC and LE Electrically Held Contactors<br />

Revised on 03/31/20<br />

Wiring Diagrams<br />

LEN00B003 (20A 3 Pole)<br />

A1 1 /L1 3 /L2 5 L3 13<br />

LEN00F003 (200A 3 Pole)<br />

LEN00G003 (300A 3 Pole)<br />

LEN00H003 (400A 3 Pole)<br />

A1 1 /L1 3 /L2 5 /L3 13 21 31 43<br />

U<br />

A2 2 /T1 4 /T2 6 /T3 14<br />

A2 2 /T1 4 /T2 6 /T3 14 22 32 44<br />

LEN00B004 (20A 4 Pole)<br />

A1 1 /L1 3 /L2 5 /L3 7 /L4<br />

LCE00C (30A 2-12 Pole)<br />

LINE<br />

1<br />

LOAD<br />

A2 2 /T1 4 /T2 6 /T3 8 /T4<br />

2<br />

3<br />

NEMA & General<br />

Purpose Control<br />

LEN00C003 (30A 3 Pole)<br />

LEN00D003 (60A 3 Pole)<br />

LEN00E003 (100A 3 Pole)<br />

A1<br />

1 /L1 3 /L2 5 /L3<br />

13<br />

21<br />

4<br />

5<br />

6<br />

A1<br />

COIL<br />

A2<br />

17<br />

A2 2 /T1 4 /T2 6 /T3 14 22<br />

COIL<br />

VOLTAGE<br />

CONTROL<br />

PRODUCTS<br />

LEN00C004 (30A 4 Pole)<br />

A1 1 /L1 3 /L2 5 /L3 7 /L4 13 21<br />

OPTIONAL<br />

AUXILIARY<br />

CONTACTS<br />

A2 2 /T1 4 /T2 6 /T3 8 /T4 14 22<br />

17-170<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Duplex Heavy Duty Controllers<br />

Class LC and LE Electrically Held Contactors<br />

Wiring Diagrams<br />

Optional Pilot Devices for Electrically Held Contactor<br />

OFF PB<br />

ON PB<br />

ON<br />

ON and OFF<br />

Push buttons<br />

L1<br />

FUSE *<br />

A2<br />

COIL<br />

A1<br />

FUSE<br />

*<br />

L2<br />

REMOTE OFF<br />

AUXILIARY<br />

CONTACT<br />

REMOTE<br />

ON<br />

AUXILIARY<br />

CONTACT<br />

OFF<br />

OFF-ON or<br />

OFF-AUTO<br />

Selector<br />

Switch<br />

L1<br />

FUSE<br />

*<br />

REMOTE<br />

DEVICE<br />

OFF<br />

SS<br />

AUTO<br />

AUXILIARY<br />

CONTACT<br />

A2<br />

ON<br />

COIL<br />

OFF<br />

A1<br />

FUSE<br />

*<br />

L2<br />

OFF-ON-AUTO<br />

HAND-OFF-AUTO<br />

Selector<br />

Switch<br />

L1<br />

FUSE<br />

*<br />

REMOTE<br />

DEVICE<br />

OFF<br />

ON<br />

AUTO<br />

AUXILIARY<br />

CONTACT<br />

A2<br />

ON<br />

COIL<br />

OFF<br />

A1<br />

FUSE<br />

*<br />

L2<br />

NEMA & General<br />

Purpose Control<br />

* -- IF USED<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-171


4<br />

HA<br />

Lighting and Heating Contactors<br />

Class LC (converted to mechanically held)<br />

LINE<br />

1<br />

2<br />

3<br />

4<br />

5<br />

LOAD<br />

OFF-ON or<br />

HAND-OFF-AUTO or<br />

OFF-AUTO<br />

ON-OFF-AUTO<br />

SELECTOR SWITCH<br />

SELECTOR SWITCH<br />

6<br />

TABLE C : OPTIONAL<br />

TABLE B : OPTIONAL PILOT DEVICES FOR 2 WIRE CONTROL Wiring Diagrams<br />

REFER TO TABLE A FOR<br />

CONTROL<br />

VOLTAGE<br />

CONTROL<br />

VOLTAGE<br />

SS<br />

2/3 WIRE CONTROL OPTIONS ON<br />

OFF (AUTO)<br />

2-WIRE CONTROL<br />

REFER TO TABLE B FOR<br />

CONTROL CONNECTIONS<br />

C<br />

OPTIONAL "N/O"<br />

AUX. CONTACT<br />

TABLE A<br />

3-WIRE CONTROL<br />

REFER TO TABLE C FOR<br />

CONTROL CONNECTIONS<br />

NOT USED<br />

ELECTRONIC-MODULE<br />

P1 P2 P3 P4 P5<br />

A1<br />

ON<br />

5<br />

A2OFF<br />

COIL<br />

AUTO<br />

REMOTE<br />

DEVICE COIL VOLTAGE<br />

ELECTRONIC-MODULE<br />

P1 P2 P3 P4 P5<br />

ELECTRONIC-MODULE<br />

P1 P2 P3 P4 P5<br />

A2<br />

ELECTRONIC-MODULE<br />

P1 P2 P3 P4 P5<br />

OPTIONAL 'N/C'<br />

AUXILIARY CONTACT<br />

A2<br />

ON & OFF<br />

PUSH BUTTONS<br />

COIL<br />

OFF-ON SELECTOR<br />

SWITCH WITH SPRING<br />

COIL<br />

OFF<br />

A1<br />

RETURN TO CENTER<br />

OFF<br />

A1<br />

ON<br />

ON<br />

FUSE<br />

CONTROL<br />

VOLTAGE<br />

FUSE<br />

CONTROL<br />

VOLTAGE<br />

FUSE<br />

FUSE<br />

*<br />

*<br />

*<br />

*<br />

COIL<br />

VOLTAGE<br />

COIL<br />

VOLTAGE<br />

REM<br />

O<br />

"NC" A<br />

NEMA & General<br />

Purpose Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

LOAD<br />

LOAD<br />

OPTIONAL 'N/C'<br />

AUXILIARY CONTACT<br />

OPTIONAL 'N/C'<br />

AUXILIARY CONTACT<br />

OPTIONAL 'N/C'<br />

AUXILIARY CONTACT<br />

ACT<br />

TABLE A<br />

TABLE B : OPTIONAL PILOT DEVICES FOR 2 WIRE CONTROL<br />

2-WIRE CONTROL<br />

SS<br />

ELECTRONIC-MODULE<br />

ELECTRONIC-MODULE<br />

ON<br />

P1 P2 P3 P4 P5<br />

OFF (AUTO) P1 P2 P3 P4 P5<br />

TABLE B : OPTIONAL PILOT DEVICES FOR 2 WIRE CONTROL<br />

REFER TO TABLE B FOR<br />

CONTROL CONNECTIONS<br />

C<br />

17-172<br />

2/3 WIRE CONTROL OPTIONS<br />

3-WIRE CONTROL<br />

REFER TO TABLE C FOR<br />

CONTROL CONNECTIONS<br />

L<br />

O<br />

C<br />

OPTIONAL "N/O"<br />

AUX. CONTACT<br />

REFER TO TABLE A FOR<br />

OPTIONAL "N/O"<br />

HAND-OFF-AUTO or OFF-ON or<br />

HAND-OFF-AUTO or AUX. CONTACT OFF-ON or<br />

ON-OFF-AUTO<br />

ON-OFF-AUTO OFF-AUTO<br />

OFF-AUTO<br />

SELECTOR SWITCH<br />

SELECTOR SWITCH SELECTOR SWITCH<br />

SELECTOR SWITCH<br />

OFF-ON SELECTOR<br />

OFF-ON SELECTOR ON & OFF<br />

SWITCH WITH SPRING<br />

ON & OFF<br />

SWITCH WITH SPRING PUSH BUTTONS<br />

RETURN TO CENTER<br />

PUSH BUTTONS<br />

RETURN TO CENTER<br />

NOT USED<br />

CONTROL<br />

VOLTAGE<br />

A1<br />

CONTROL<br />

VOLTAGE<br />

CONTROL<br />

VOLTAGE<br />

COIL<br />

6<br />

COIL VOLTAGE<br />

A2<br />

ELECTRONIC-MODULE<br />

P1 P2 P3 P4 P5<br />

CONTROL<br />

VOLTAGE<br />

A1<br />

COIL<br />

COIL VOLTAGE<br />

A2<br />

REMOTE<br />

DEVICE<br />

OPTIONAL 'N/C'<br />

AUXILIARY CONTACT<br />

ONAUTO<br />

OPTIONAL 'N/C'<br />

AUXILIARY CONTACT<br />

ON<br />

(AUTO)<br />

AUTO<br />

ON & OFF<br />

PUSH BUTTONS<br />

OFF-ON SELECTOR<br />

SWITCH WITH SPRING<br />

RETURN TO CENTER<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

OFF<br />

SS<br />

TABLE C : OPTIONAL PILOT DEVICES FOR 3 WIRE CONTROL<br />

CONTROL<br />

VOLTAGE<br />

ELECTRONIC-MODULE<br />

CONTROL<br />

VOLTAGE<br />

L<br />

O<br />

C<br />

OPTIONAL "N/O"<br />

AUX. CONTACT<br />

P1 P2 P3 P4 P5<br />

COIL<br />

A2<br />

ELECTRONIC-MODULE<br />

COIL<br />

P1 P2 P3 P4 P5<br />

A2<br />

ELECTRONIC-MODULE<br />

P1 P2 P3 P4 P5<br />

TABLE C : OPTIONAL PILOT DEVICES FOR 3 WIRE CONTROL<br />

TABLE C : OPTIONAL PILOT DEVICES FOR 3 WIRE CONTROL<br />

CONTROL<br />

VOLTAGE<br />

CONTROL<br />

VOLTAGE<br />

CONTROL<br />

VOLTAGE<br />

CONTROL<br />

VOLTAGE<br />

REMOTE<br />

DEVICE<br />

OFF<br />

REMOTE<br />

OFF<br />

ON<br />

REMOTE<br />

ON<br />

REMOTE<br />

ON<br />

REMOTE<br />

OFF<br />

"NC" AUXILIARY<br />

"NC" AUXILIARY<br />

OFF<br />

ON<br />

ON<br />

"NO"<br />

AUXILIARY<br />

OFF<br />

"NO"<br />

AUXILIARY<br />

ON<br />

OFF<br />

ON<br />

OFF<br />

OFF<br />

A2<br />

COIL<br />

"NO"<br />

AUXILIARY<br />

ELECTRONIC-MODULE<br />

P1 P2 P3 P4 P5<br />

"NO"<br />

AUXILIARY<br />

ELECTRONIC-MODULE<br />

P1 P2 P3 P4 P5<br />

"NC" AUXILIARY<br />

A2<br />

A2<br />

A2<br />

ELECTRONIC-MODULE<br />

P1 P2 P3 P4 P5<br />

A1<br />

A2<br />

REMOTECOIL<br />

OFF<br />

COIL VOLTAGE OFF<br />

ON<br />

REMOTE<br />

ON<br />

FUSE<br />

*<br />

"NO"<br />

OFF ON<br />

AUXILIARY<br />

*<br />

FUSE *<br />

FUSE<br />

A1<br />

OFF<br />

OFF<br />

A1<br />

ELECTRONIC-MODULE COIL<br />

"NC" AUXILIARY P1 P2 P3 P4 P5<br />

A2<br />

A2<br />

COIL<br />

COIL<br />

COIL<br />

COIL<br />

ON<br />

FUSE<br />

"NC" AUXILIARY<br />

FUSE<br />

OFF<br />

A1<br />

OFF<br />

A1<br />

OFF<br />

A1<br />

OFF<br />

A1<br />

OFF<br />

A1<br />

OFF<br />

A1<br />

ON<br />

ON<br />

FUSE<br />

FUSE<br />

ON<br />

ON<br />

ON<br />

FUSE<br />

ON *<br />

FUSE<br />

FUSE<br />

*<br />

*<br />

*<br />

*<br />

FUSE<br />

*<br />

FUSE<br />

FUSE<br />

FUSE<br />

*<br />

* ON -- IF USED<br />

*<br />

*<br />

*<br />

FUSE *<br />

FUSE<br />

* -- IF USED<br />

*<br />

*<br />

COIL<br />

VOLTAGE<br />

COIL<br />

VOLTAGE<br />

COIL<br />

VOLTAGE<br />

COIL<br />

VOLTAGE<br />

OPTIONAL 'N/C'<br />

AUXILIARY CONTACT<br />

"NO"<br />

AUXILIARY<br />

ELECTRONIC-MODULE<br />

P1 P2 P3 P4 P5<br />

"NC" AUXILIARY<br />

COIL<br />

VOLTAGE<br />

COIL<br />

VOLTAGE<br />

COIL<br />

VOLTAGE<br />

COIL<br />

VOLTAGE<br />

A2<br />

ELECTRONIC-MODULE<br />

P1 P2 P3 P4 P5<br />

A2<br />

COIL<br />

COIL<br />

OFF<br />

A1<br />

OFF<br />

A1<br />

*<br />

FUSE<br />

ON<br />

*<br />

FUSE<br />

*<br />

FUSE<br />

ON<br />

*<br />

FUSE<br />

* -- IF USED<br />

COIL<br />

VOLTAGE<br />

COIL<br />

VOLTAGE


Lighting and Heating Contactors<br />

Mechanically Latched 20 Amp, Class CLM<br />

Wiring Diagrams<br />

ON<br />

OFF<br />

CONTACTOR CONTROL<br />

VOLTAGE<br />

OFF<br />

L<br />

L<br />

C<br />

0<br />

ON<br />

OFF<br />

TYPICAL OFF-ON<br />

SELECTOR SWITCH<br />

COMMON OR SEPARATE<br />

CONTROL LINES<br />

CONTROL<br />

MODULE<br />

VOLTAGE<br />

ON<br />

OFF<br />

2<br />

3<br />

4<br />

5<br />

CR1<br />

CR2<br />

CR2<br />

CR1<br />

3 WIRE CONTROL ACC. 48<br />

CR1<br />

CR2<br />

L<br />

0<br />

ON<br />

C<br />

COIL<br />

PILOT LIGHTS<br />

REQUIRE (1) EA.<br />

CLM4097291<br />

AUXILIARY<br />

CONTACT KIT.<br />

ON<br />

CONTACTOR CONTROL<br />

VOLTAGE<br />

L<br />

CONTACTOR CONTROL<br />

VOLTAGE<br />

L<br />

CONTROL<br />

MODULE<br />

VOLTAGE<br />

HAND<br />

OFF<br />

AUTO<br />

3<br />

4<br />

CR<br />

5<br />

CR<br />

CR<br />

0<br />

C<br />

OFF<br />

COIL<br />

L<br />

CONTROL<br />

MODULE<br />

VOLTAGE<br />

OFF<br />

2<br />

4<br />

CR2<br />

3 5<br />

CR1<br />

CR2<br />

CR1<br />

CR1<br />

0<br />

C<br />

OFF<br />

COIL<br />

L<br />

REMOTE<br />

CONTROL<br />

ON<br />

2 WIRE CONTROL ACC. 47 ON-OFF (FORM 3) CONTROL ACC. 49<br />

ON<br />

CONNECTIONS TO CONTROL MODULES<br />

CONTACTOR CONTROL<br />

VOLTAGE<br />

L<br />

MODULE<br />

TERMINAL<br />

CONNECT TO:<br />

CONTROL<br />

MODULE<br />

VOLTAGE<br />

ON-OFF<br />

3<br />

4<br />

5<br />

CR<br />

CR<br />

CR<br />

2 WIRE CONTROL ACC. 47<br />

0<br />

C<br />

OFF<br />

ON<br />

COIL<br />

L<br />

1<br />

2<br />

3<br />

4<br />

5<br />

O<br />

C<br />

CONT. STATION FOR ACC. 48 & 49<br />

CONT. STATION FOR ACC. 47,48 & 49<br />

MODULE CONTROL VOLTAGE *<br />

CONTACTOR CONTROL VOLTAGE<br />

TERMINAL O ON CONTACTOR<br />

"<br />

TERMINAL C ON CONTACTOR<br />

"<br />

* FOR 24 VDC CONTROL MODULES<br />

CONNECT TERMINAL 4 TO NEGATIVE (-)<br />

"<br />

"<br />

NOT USED<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-173


Lighting and Heating Contactors<br />

Mechanically Latched 30-400 Amps, Class CLM<br />

Wiring Diagrams<br />

Mechanically Latched, CLM 30–200 Amps<br />

CONTROL<br />

VOLTAGE<br />

(L1)<br />

1<br />

(L2)<br />

X2<br />

H<br />

O<br />

A<br />

SELECTOR<br />

SWITCH<br />

CR<br />

REMOTE<br />

DEVICE<br />

( + )<br />

CLM CONTACTOR<br />

CR<br />

CR<br />

ON<br />

OFF<br />

( - )<br />

BLACK ( + )<br />

CLMFCCK11<br />

RED AC<br />

3<br />

WHITE<br />

( - )<br />

2<br />

RED<br />

AC<br />

L2<br />

RED<br />

ON<br />

OFF<br />

NEMA & General<br />

Purpose Control<br />

Connection Diagram for Common/Separate<br />

Control with Momentary Pushbutton or<br />

ON-OFF Selector Switch CLMOC, CLMOD,<br />

CLMOE, and CLMOF<br />

Mechanically Latched Type CLM 300 and 400 Amp<br />

Connection for 2-Wire Control CLMOC,<br />

CLMOD, CLMOE, and CLMOF<br />

Connection for Hand/Off/Auto Control<br />

CLMOC, CLMOD, CLMOE, and CLMOF<br />

CONTROL<br />

VOLTAGE<br />

(L1)<br />

1<br />

(L2)<br />

X2<br />

H<br />

O<br />

A<br />

17<br />

SELECTOR<br />

SWITCH<br />

CR<br />

CONTROL<br />

PRODUCTS<br />

CR<br />

CR<br />

REMOTE<br />

DEVICE<br />

CLM CONTACTOR<br />

ON OFF<br />

Closing<br />

Trip<br />

Coil<br />

Solenoid<br />

Coil<br />

L2<br />

CLMHCCK11<br />

3<br />

2<br />

ON<br />

OFF<br />

Connection Diagram for Common/Separate<br />

Control with Momentary Pushbutton or<br />

ON-OFF Selector Switch CLMOG and<br />

CLMOH<br />

Connection for 2-Wire Control CLMOG and<br />

CLMOH<br />

Connection for Hand/Off/Auto Control<br />

CLMOG and CLMOH<br />

Control relay is required for 2-wire and Hand/Off/Auto<br />

Control, as shown in diagram.<br />

17-174<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


240V<br />

230V<br />

220V<br />

480V<br />

230V<br />

460V<br />

220V<br />

440V<br />

H1 H3 H2 H4<br />

H1 H3 H2 H4 H1 H3 H2 H4<br />

H1 H3 H2 H4<br />

H1 H3<br />

Industrial Control Power Transformers<br />

460V<br />

440V<br />

240V<br />

H1 H3 H2 H1 H4H3<br />

H2 H4<br />

H2 H4 H1 H3<br />

230V<br />

240V<br />

480V 220V<br />

H1 H3 H2 H4<br />

H1 H3 H2 H4<br />

H1 H3 H2 H4<br />

H1 H3<br />

H1 H3<br />

H2 H4<br />

460V<br />

480V 440V<br />

H1 H3 H2 H4<br />

H1 H3 H2 H4<br />

H2 H4<br />

H2 H4<br />

H1 H3 H2 H<br />

H1 H3<br />

480V<br />

460V<br />

440V<br />

1 H3 H2 H4<br />

H2 H4<br />

Class MT, MTG<br />

Voltage Letter A ac<br />

240V<br />

240V<br />

480V<br />

230V<br />

230V<br />

460V<br />

220V<br />

440V<br />

220V<br />

240V<br />

480V<br />

H1 H3 H2 H4 H1 H1 H3 H3 H2 H2 H4 H4<br />

H1 H3<br />

H1 H3 H2 H4<br />

H1 H3<br />

H2 H4 H1 H3<br />

H1 H3 H2 H4<br />

H2 H4<br />

480V<br />

460V<br />

440V<br />

240V<br />

H1 H3 H2 H1 H4H3<br />

H2 H4<br />

H2 H4 H1 H3<br />

X2<br />

480V<br />

Voltage N/A Letter F B bc X1<br />

240V<br />

120V<br />

120V<br />

115V<br />

110V<br />

X2<br />

N/A<br />

480V<br />

240V120V<br />

120V<br />

115V<br />

110V<br />

F<br />

240V<br />

X2<br />

X1<br />

115V<br />

N/A<br />

24V<br />

F<br />

X2<br />

X2<br />

120V<br />

115V<br />

110V 24V<br />

N/A<br />

X1<br />

N/A<br />

F<br />

Voltage Letter C bc<br />

120V<br />

230V115V<br />

Wiring Diagrams<br />

H1 H3 H2 H1 H4 H3 H2 H4 H1 H3 H2 H4<br />

H1 H3 H2 H4 H1 H3 H2 H4<br />

H2 H1 H4 H3H1 H2 H3H4<br />

H1 H3 H2<br />

H1<br />

H4 H2 H3 H4 H2 H4 H1 H3 H1 H2 H3 H4 H2 H4 H1 H3 H1 H2 H3 H1 H4 H2 H3 H4 H1 H2 H3 H4 H2 H4<br />

H1 H3 H2 H4H1 H3 H2 H4 H1 H3 H2 H4H1 H3 H2 H4<br />

240V<br />

230V<br />

X1<br />

X1<br />

X2 N/A<br />

115V<br />

H1 H3 H2 H<br />

H1 H3<br />

V<br />

V<br />

V<br />

V<br />

V<br />

V<br />

V<br />

F<br />

H1 H3<br />

F<br />

F<br />

F<br />

240V<br />

H2 H4<br />

N/A<br />

H3<br />

230V<br />

H3<br />

400V<br />

X1<br />

H2 H4<br />

460V<br />

H4<br />

X1<br />

X1<br />

H2<br />

415V<br />

X1<br />

H4<br />

X2<br />

120V<br />

Voltage Letter D b<br />

115V<br />

H1 H3 H2 H4<br />

H1 H3<br />

H1 H3 H2 H4<br />

X2<br />

X2<br />

H1<br />

H1<br />

X2<br />

X2<br />

X2<br />

H1<br />

H1<br />

N/A<br />

24V<br />

X1<br />

N/A<br />

X1<br />

Voltage 575V Letter H1 G a<br />

X2<br />

X3<br />

0V<br />

N/A<br />

H2<br />

120V<br />

115V<br />

110V<br />

208V<br />

115V<br />

N/A<br />

N/A<br />

240V<br />

120V<br />

230V<br />

H1 H3 H2 H4<br />

H1 H3 H2 H4<br />

H2 H4<br />

H1 H3 H2 H4<br />

H1 H3<br />

H2 H4<br />

Voltage Letter J bc<br />

H1<br />

H4<br />

0V<br />

120V<br />

115V<br />

110V<br />

24V<br />

N/A F<br />

X2<br />

N/A F<br />

H1 H3<br />

0V<br />

0V<br />

115V<br />

0V<br />

N/A<br />

F<br />

H3<br />

24V<br />

208V<br />

230V<br />

120V<br />

380V<br />

208V<br />

X2<br />

F<br />

X2 F<br />

230V<br />

F<br />

F<br />

X2<br />

FX2<br />

95V<br />

0V<br />

460V<br />

X1 24V<br />

X1<br />

N/A<br />

X1 N/A<br />

H2 H3H1<br />

H4<br />

H2<br />

400V<br />

H3<br />

460V<br />

230V<br />

N/A X1<br />

277V<br />

575V<br />

0V<br />

H4<br />

X1<br />

X1<br />

H1<br />

0V<br />

415V<br />

460V<br />

120V<br />

115V<br />

110V<br />

F<br />

X2<br />

X1<br />

115V<br />

N/A<br />

24V<br />

24V<br />

F<br />

X2 N/A<br />

230V<br />

115V<br />

Voltage Letter E ac<br />

H1<br />

N/A H1 N/A H2 N/A N/A H1 H2<br />

H1 H3 H2 H4 H1 H3 H1 H2 H4 H2 H3 H4<br />

H1<br />

600V<br />

600V<br />

H1 H3 H2 H4<br />

H1 H3 H2 H4 H1 H3 H2 H4<br />

H1 H3 H2 H4 575V<br />

575V<br />

550V<br />

550V<br />

H2 H4<br />

H1 H3 H2 H4<br />

H1<br />

H2 H3 H4<br />

X2<br />

N/A N/A H2<br />

H1<br />

600V<br />

H2 N/A H3<br />

N/A<br />

550V<br />

N/A H2<br />

H2 H1 H3 H4<br />

600V<br />

H2<br />

575V<br />

H3 H1H4<br />

550V<br />

208V<br />

120V<br />

115V<br />

110V<br />

115V<br />

F<br />

F<br />

F<br />

240V<br />

230V<br />

X2<br />

X1<br />

0V<br />

460V<br />

0V<br />

115V<br />

X1<br />

X3 X1<br />

H4<br />

H2 H3 H4<br />

380V<br />

400V<br />

415V<br />

0V<br />

N/A<br />

N/A<br />

F<br />

208V<br />

120V<br />

F<br />

X1<br />

X2<br />

N/A N/A<br />

H2<br />

X2<br />

N/A<br />

N/A<br />

H3<br />

H3<br />

H2<br />

230V<br />

208V<br />

H1<br />

H3<br />

460V<br />

95V<br />

230V<br />

0V<br />

Voltage Letter X2H<br />

277V<br />

0V 0V<br />

575V<br />

115V<br />

0V<br />

H4<br />

460V<br />

24V<br />

X1<br />

X2 N/A 24V<br />

H1<br />

0V<br />

0V<br />

208V<br />

120V<br />

115V<br />

110V<br />

115V 24V<br />

230V 380V 208V<br />

F<br />

FX2<br />

F<br />

230V<br />

X1<br />

H2 N/A H3 N/A<br />

H2 H3 H4 H4<br />

208V<br />

FX2<br />

230V<br />

460V<br />

400V<br />

95V<br />

230V<br />

X1 N/A<br />

460V<br />

0V<br />

575V<br />

415V 277V<br />

0V<br />

460V<br />

24V<br />

208V<br />

120V<br />

115V<br />

110V<br />

N/A X1 X1<br />

115V<br />

X1<br />

H1<br />

0V<br />

380V<br />

F<br />

230V<br />

X2<br />

X1 N/A<br />

0V<br />

460V<br />

H4<br />

0V<br />

115V<br />

415V<br />

0V<br />

115V<br />

24V<br />

208V<br />

120V<br />

X2 N/A<br />

F X1<br />

X3 F<br />

F<br />

F X2<br />

FX2<br />

X1 N/A<br />

Voltage Letter F a<br />

600V<br />

H2 N/A H1 H3 575V<br />

H2 N/A H3<br />

H2 H3 H4<br />

H1<br />

H2550V<br />

H3 H4<br />

H3<br />

230V<br />

208V<br />

X2 X2<br />

0V<br />

460V<br />

0V<br />

277V<br />

95V<br />

H1<br />

H2<br />

0V<br />

X1N/A<br />

Voltage F Letter X2 I<br />

0V<br />

230V<br />

24V<br />

24V<br />

N/A<br />

575V<br />

208V<br />

208V<br />

120V<br />

N/A 115V<br />

N/A X1<br />

H1<br />

H2 H3 H4<br />

F X1<br />

X4 X2 120V X3 X1<br />

X4 X2 X3 X1<br />

X4 X2 X3 X1 X4 X2 X3 X4 X1 X2 X3 X1<br />

X4 X2 X3 X1 X4 X2 X3 X1<br />

X2 N/A F X1<br />

X4 X2 X3 X1 X4 X2 X3 X1<br />

X2 X3 X1 F X2 X1<br />

110V<br />

220V<br />

110V<br />

220V<br />

110V<br />

220V X1 F X2 X3<br />

X1 F X2 X3<br />

H2H4<br />

Voltage H1 H3 Letter H2 L H1<br />

Voltage Letter M a<br />

240V<br />

480V<br />

H1 240V H2 H3 480V H4 H5<br />

H1 H2 H3 H4 H5<br />

H1 H2 H3 H4 H5<br />

600V<br />

600V<br />

H1 H3 H2 H4 H1 H3 H2 H4 480V 575V<br />

480V 575V<br />

600V<br />

H1 H3 H2 216V H4 H1 460V H3 H2 550VH4<br />

216V 460V 550V<br />

480V 575V<br />

240V 220V 200V 440V 500V<br />

240V 220V 200V 440V 500V 216V 460V 550V H4 H3 H2 H4<br />

200V 440V 500V<br />

230V 208V H4 H3380V<br />

H2 H4<br />

230V 208V 380V<br />

240V 220V<br />

230V 208V 380V<br />

X1<br />

H2 H3 H4<br />

400V<br />

X2<br />

H1<br />

H1<br />

X2<br />

X3<br />

H4<br />

0V<br />

115V<br />

0V<br />

115V<br />

H3<br />

H2<br />

120V<br />

115V<br />

110V<br />

230V<br />

460V 380V<br />

208V<br />

0V<br />

24V<br />

F<br />

F<br />

H3<br />

460V<br />

F<br />

F<br />

95V<br />

H2<br />

230V<br />

24V<br />

277V<br />

575V<br />

0V<br />

H4<br />

X1<br />

H1<br />

X1<br />

X1<br />

N/A N/A H2<br />

230V<br />

F<br />

400V<br />

460V<br />

X1<br />

X1<br />

415V<br />

X1<br />

460V<br />

0V<br />

X2 N/A<br />

H1<br />

H1<br />

X2<br />

X3<br />

H4<br />

115V<br />

0V 0V<br />

115V<br />

0V<br />

17 CONTROL<br />

PRODUCTS<br />

X1<br />

240V<br />

N/A<br />

F<br />

H3<br />

H1 H3 H2<br />

F<br />

H4 H3<br />

X3 X1<br />

X4 X2 X3 X1<br />

220V<br />

X4 X2 X3 X1X4 X2 X3 X1<br />

115V<br />

X4 X2 X3 X1 X4 X2X4 X3 X2X1X3 X1 X4 X2 X3 X1<br />

115V<br />

24V<br />

0V<br />

110V<br />

220V110V<br />

220V<br />

X1<br />

X1 F X2 X3<br />

F<br />

99V 91V<br />

99V 91V<br />

99V 91V<br />

120V 95V 85V<br />

120V 95V 85V<br />

120V 95V 85V<br />

130V 115V<br />

130V 115V<br />

130V 115V<br />

X4 X2 X3 125V 110V<br />

X4 X1X2<br />

X3 X1<br />

125V 110V<br />

125V 110V<br />

120V 100V<br />

120V 100V<br />

120V 100V<br />

X4 X2 X3 X1 X4<br />

X4 110V<br />

X2<br />

X2 X3 X1<br />

X1<br />

X4 X2 X3 X1<br />

110V<br />

110V<br />

X2X1<br />

X3 F X2X4<br />

X3<br />

X4 X3 X2 X1<br />

X3 X2 X1<br />

X4 X3 X2 X1<br />

110V<br />

220V<br />

110V<br />

220V<br />

24V<br />

115V<br />

0V<br />

24V<br />

0V<br />

X4 X2<br />

X4 X2 X3<br />

110V<br />

H3 H4 H5<br />

600V<br />

480V 575V<br />

460V 550V<br />

440V 500V<br />

240V<br />

H1 240V H2 H1H3 480V<br />

H4 H5 H2 H3 H4 H5<br />

600V<br />

600V H1 H3 H2 H4<br />

480V 575V<br />

480V 575V<br />

H1 H3 H2 H4 216V 460V 550V<br />

240V 220V 200V<br />

H1 440V H3 H2 500V H4<br />

216V 460V 550V<br />

240V 220V 200V 440V 500V H4 H3<br />

230V 208V 380V 230V 208V 380V<br />

H4 H3 H2 H4<br />

480V240V<br />

480V<br />

Voltage Letter P<br />

H1 H3 H1 H2 H3 H4 H2 H4 H1 H3 H2 H4<br />

H1H2 H4 H4 H3 N/A N/A H2 H4 H2<br />

380V<br />

99V 91V<br />

95V 85V<br />

X1<br />

99V 91V<br />

99V 91V<br />

120V 95V 85V 120V 95V 85V<br />

130V 115V<br />

130V 115V<br />

X4 X2 X3 X1X4 X2 X3 X1<br />

125V 110V<br />

125V 110V<br />

120V X4 X2100V<br />

X3 X1120V<br />

100V<br />

X4 X2 X3 X1 X4 X2 X4 X2 X3 X3 X1 X1 X4 X2 X3 X1<br />

110V<br />

110V<br />

X4 X4 X2X3X3 X1 X2 X4 X2 X3 X1 X1<br />

24V<br />

X4 X3 X2 X1<br />

110V<br />

220V 110V<br />

220V<br />

a Includes secondary 110V fuse clips 220V on sizes 50-750VA<br />

b Includes secondary fuse clips on sizes 50-500VA<br />

c Secondary fuse clips are not included on MTG<br />

transformers.<br />

X2 N/A N/A X1<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-175


Enclosed IEC Controls<br />

3RE4 IEC Controllers<br />

Revised on 05/31/19<br />

General information<br />

3RE4 Enclosed IEC Controllers<br />

­<br />

Product overview<br />

3RE4 Enclosed IEC motor controllers<br />

are well suited for both industrial and<br />

commercial applications. They are durable<br />

and dependable, particularly when it<br />

comes to motor protection. Protecting the<br />

performance of motors is a critical priority<br />

and the 3RE4 enclosed starters are offered<br />

with either thermal or solid-state overload<br />

relays to maximize your motor protection.<br />

Soft Starter<br />

Control<br />

Controller Features<br />

General<br />

n UL motor horsepower rated<br />

n From fractional up to 60 Hp at 575 V<br />

n Non-combination type starters and contactors<br />

n Reversing and non-reversing controllers<br />

n Single phase and 3-phase loads<br />

n Thermal and solid-state overload relays<br />

n NEMA Type enclosures 1, 3/3R/4/12 and 4X 304 stainless steel<br />

n Standard size and extra larger enclosures<br />

n RoHS compliant<br />

n Standards: UL 60947-4-1<br />

n Certifications: cULus<br />

Contactor<br />

n Horsepower rated per UL<br />

n High contact reliability<br />

n NO and NC auxiliary contacts included as standard<br />

n Permanently secured with screws on mounting panel<br />

n Screw type terminal connections<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Overload Relay Features<br />

Thermal overload relays<br />

n Trip Class 10<br />

n Phase failure sensitivity<br />

n UL for Single and three phase loads<br />

n Includes NC trip contact and NO alarm contact<br />

n Manual and automatic RESET (selectable)<br />

n Switch position indicator<br />

n TEST function<br />

n STOP button<br />

n Sealable cover (optional)<br />

n Screw-type terminals<br />

Solid-state overload relays<br />

n Selectable Trip Class 5, 10, 20 and 30<br />

n Overload, phase failure and unbalance protection<br />

n Internal ground fault detection (selectable)<br />

n Internal power supply<br />

n Includes NC trip contact and NO alarm contact<br />

n Manual and automatic RESET (selectable)<br />

n Electrical remote RESET integrated<br />

n Switch position indicator<br />

n TEST function and self-monitoring<br />

n Sealable cover (optional)<br />

n Screw-type terminals<br />

Available Factory Mods, Field Kits, Accessories<br />

Factory modifications<br />

n Push buttons<br />

n Selector switches<br />

n Pilot lights<br />

n Control power transformers<br />

Field kits and accessories<br />

n Push buttons<br />

n Selector switches<br />

n Pilot lights<br />

n Auxiliary contacts<br />

n Control power transformers<br />

n Control relays and timers<br />

n Control circuit fuse block<br />

n Terminal blocks<br />

n etc.<br />

17-176<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Enclosed IEC Controls<br />

3RE4 IEC Controllers<br />

Catalog Numbering System<br />

3RE4 Nomenclature<br />

Non-Combination Controllers<br />

Revised on 05/31/19<br />

Catalog Numbering System<br />

3RE4 1 2 2 – 3 A A 3 1 – 1 H Y 0<br />

Controller Type<br />

11 = Non-combination non-reversing starter,1-phase, 2-pole<br />

12 = Non-combination non-reversing starter,3-phase, 3-pole<br />

14 = Non-combination reversing starter, 3-phase, 3-pole<br />

16 = Non-combination non-reversing contactor<br />

18 = Non-combination reversing contactor<br />

Frame Size: UL60947-4-1 Hp Rating<br />

15 = S00: 1-Ph Hp (0.25@115V, 0.5@208V, 0.75@230V), 3-Ph Hp (1.5@208V, 2@230V, 3@460V, 5@575V)<br />

23 = S0: 1-Ph Hp (1@115V, 1@208V, 1@230V), 3-Ph Hp (2@208V, 3@230V, 5@460V, 7.5@575V)<br />

24 = S0: 1-Ph Hp (1@115V, 2@208V, 2@230V), 3-Ph Hp (3@208V, 3@230V, 7.5@460V, 10@575V)<br />

25 = S0: 1-Ph Hp (1@115V, 2@208V, 3@230V), 3-Ph Hp (5@208V, 5@230V, 10@460V, 15@575V)<br />

26 = S0: 1-Ph Hp (2@115V, 3@208V, 3@230V), 3-Ph Hp (7.5@208V, 7.5@230V, 15@460V, 20@575V)<br />

27 = S0: 1-Ph Hp (2@115V, 5@208V, 5@230V), 3-Ph Hp (10@208V, 10@230V, 20@460V, 25@575V)<br />

28 = S0: 1-Ph Hp (3@115V, 5@208V, 5@230V), 3-Ph Hp (10@208V, 10@230V, 25@460V, 25@575V)<br />

35 = S2: 1-Ph Hp (3@115V, 5@208V, 7.5@230V), 3-Ph Hp (10@208V, 15@230V, 30@460V, 40@575V)<br />

36 = S2: 1-Ph Hp (3@115V, 7.5@208V, 10@230V), 3-Ph Hp (15@208V, 15@230V, 40@460V, 50@575V)<br />

37 = S2: 1-Ph Hp (5@115V, 10@208V, 10@230V), 3-Ph Hp (20@208V, 20@230V, 50@460V, 50@575V)<br />

38 = S2: 1-Ph Hp (5@115V, 10@208V, 15@230V), 3-Ph Hp (20@208V, 25@230V, 50@460V, 60@575V)<br />

Soft Starter<br />

Control<br />

Enclosure Type and Size<br />

A = NEMA Type 1 - standard size<br />

B = NEMA Type 1 - large size a<br />

C = NEMA Type 3/3R/4/12 - standard size<br />

E = NEMA Type 4X 304 SS - standard size<br />

Disconnect Type<br />

A = None<br />

Nominal Coil Voltage<br />

1 = 24 V AC 50/60Hz<br />

2 = 24 V DC<br />

3 = 110/120 V AC 50/60Hz<br />

4 = 208 V AC 50/60Hz<br />

5 = 220/240 V AC 50/60Hz<br />

6 = 277 V AC 60Hz<br />

7 = 480 V AC 60Hz<br />

8 = 600 V AC 60Hz<br />

17 CONTROL<br />

PRODUCTS<br />

Overload Relay Type<br />

0 = (none)<br />

1 = Thermal fixed trip Class 10<br />

5 = Solid-state selectable trip Class 5-10-20-30<br />

Overload Relay Amp Range<br />

0Y = No overload relay (contactor)<br />

See amp range selection on page 17-235.<br />

Special<br />

Y0 = (none)<br />

Factory modifications (See selection starting on page 17-238.)<br />

a Large size enclosures are not applicable for some configurations.<br />

Refer to product selection tables for specifics.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-177


Enclosed IEC Controls<br />

3RE4 Non-Reversing Starter, 3-Phase, 3-Pole, Thermal or Solid-State Overload Relay<br />

Revised on 05/31/19<br />

Selection<br />

Ordering Information<br />

Replace the (●) with the code from the coil<br />

table on this page.<br />

Replace the () with the overload relay<br />

(OLR) code from this page.<br />

Replace the (♦♦) with the OLR current<br />

adjustment range from pg. 17-216.<br />

For factory modifications,<br />

see page 17-217 – 17-218.<br />

For accessories, see page 17-220 – 17-262.<br />

For replacement parts, see page 17-262.<br />

For dimensions, see page 17-281.<br />

For wiring diagrams, see page 17-284 – 17-290.<br />

Coil Selection (●) a<br />

Nominal Voltage<br />

Code<br />

24 VAC 50/60 Hz 1<br />

24 VDC 2<br />

110/120 VAC 50/60 Hz 3<br />

208 VAC 50/60 Hz 4<br />

220/240 VAC 50/60 Hz 5<br />

277 VAC 60 Hz 6<br />

480 VAC 60 Hz 7<br />

600 VAC 60 Hz 8<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Non-Reversing Starter, 3-Phase, 3-Pole, Thermal or Solid-State Overload Relay, Standard Enclosure<br />

3-Phase Motor Hp Rating per UL<br />

NEMA Type Enclosure (Standard Size)<br />

Type 1<br />

General Purpose,<br />

Indoor only<br />

Type 3/3R/4/12<br />

Weatherproof, Watertight,<br />

Dust-tight<br />

Type 4X 304 Stain. Steel<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

Unused<br />

Auxiliary<br />

Contacts<br />

Frame<br />

Size<br />

Contactor<br />

(for ref. only)<br />

208 V 230 V 460 V 575 V Catalog Number Catalog Number Catalog Number NO NC<br />

1.5 2 3 5 3RE4121–5AA●–♦♦Y0 3RE4121–5CA●–♦♦Y0 3RE4121–5EA●–♦♦Y0 1 0 S00 3RT2015<br />

2 3 5 7.5 3RE4122–3AA●–♦♦Y0 3RE4122–3CA●–♦♦Y0 3RE4122–3EA●–♦♦Y0 1 1 S0 3RT2023<br />

3 3 7.5 10 3RE4122–4AA●–♦♦Y0 3RE4122–4CA●–♦♦Y0 3RE4122–4EA●–♦♦Y0 1 1 S0 3RT2024<br />

5 5 10 15 3RE4122–5AA●–♦♦Y0 3RE4122–5CA●–♦♦Y0 3RE4122–5EA●–♦♦Y0 1 1 S0 3RT2025<br />

7.5 7.5 15 20 3RE4122–6AA●–♦♦Y0 3RE4122–6CA●–♦♦Y0 3RE4122–6EA●–♦♦Y0 1 1 S0 3RT2026<br />

10 10 20 25 3RE4122–7AA●–♦♦Y0 3RE4122–7CA●–♦♦Y0 3RE4122–7EA●–♦♦Y0 1 1 S0 3RT2027<br />

10 10 25 25 3RE4122–8AA●–♦♦Y0 3RE4122–8CA●–♦♦Y0 3RE4122–8EA●–♦♦Y0 1 1 S0 3RT2028<br />

10 15 30 40 3RE4123–5AA●–♦♦Y0 3RE4123–5CA●–♦♦Y0 3RE4123–5EA●–♦♦Y0 1 1 S2 3RT2035<br />

15 15 40 50 3RE4123–6AA●–♦♦Y0 3RE4123–6CA●–♦♦Y0 3RE4123–6EA●–♦♦Y0 1 1 S2 3RT2036<br />

20 20 50 50 3RE4123–7AA●–♦♦Y0 3RE4123–7CA●–♦♦Y0 3RE4123–7EA●–♦♦Y0 1 1 S2 3RT2037<br />

20 25 50 60 3RE4123–8AA●–♦♦Y0 3RE4123–8CA●–♦♦Y0 3RE4123–8EA●–♦♦Y0 1 1 S2 3RT2038<br />

<br />

Thermal overload relay Class 10 = 1<br />

Solid-state overload relay selectable Class = 5<br />

Non-Reversing Starter, 3-Phase, 3-Pole, Thermal or Solid-State Overload Relay, Large Enclosure<br />

3-Phase Motor Hp Rating per UL<br />

NEMA Type Enclosure (Large Size)<br />

Type 1<br />

General Purpose,<br />

Indoor only<br />

<br />

1<br />

5<br />

Type 3/3R/4/12<br />

Weatherproof, Watertight,<br />

Dust-tight<br />

<br />

1<br />

5<br />

Type 4X 304 Stain. Steel<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

Unused<br />

Auxiliary<br />

Contacts<br />

Frame<br />

Size<br />

Contactor<br />

(for ref. only)<br />

208 V 230 V 460 V 575 V Catalog Number Catalog Number Catalog Number NO NC<br />

1.5 2 3 5 3RE4121–5BA●–♦♦Y0<br />

1 0 S00 3RT2015<br />

2 3 5 7.5 3RE4122–3BA●–♦♦Y0 1 1 S0 3RT2023<br />

3 3 7.5 10 3RE4122–4BA●–♦♦Y0 1 1 S0 3RT2024<br />

5 5 10 15<br />

Not applicable — Standard enclosure includes<br />

3RE4122–5BA●–♦♦Y0 1 1 S0 3RT2025<br />

extra mounting space for accessories.<br />

7.5 7.5 15 20 3RE4122–6BA●–♦♦Y0 1 1 S0 3RT2026<br />

10 10 20 25 3RE4122–7BA●–♦♦Y0 1 1 S0 3RT2027<br />

10 10 25 25 3RE4122–8BA●–♦♦Y0 1 1 S0 3RT2028<br />

<br />

Thermal overload relay Class 10 = 1<br />

Solid-state overload relay selectable Class = 5<br />

a For 3-phase controllers, 208 - 600 V coils will be wired<br />

for incoming voltage. 24 and120 V coils will be wired<br />

as separate source or control power transformer<br />

secondary (if ordered). For single phase controllers,<br />

120 and 240 V coils will be wired for incoming voltage.<br />

24 V coils will be wired as separate source or control<br />

power transformer secondary (if ordered). 277 - 600 V<br />

coils do not apply.<br />

17-178<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Enclosed IEC Controls<br />

3RE4 Non-Reversing Starter, 1-Phase, 2-Pole, Thermal Overload Relay<br />

Revised on 05/31/19<br />

Selection<br />

Ordering Information<br />

Replace the (●) with the code from the coil<br />

table on this page.<br />

Replace the () with the overload relay<br />

(OLR) code from this page.<br />

Replace the (♦♦) with the OLR current<br />

adjustment range from pg. 17-216.<br />

For factory modifications,<br />

see page 17-217 – 17-218.<br />

For accessories, see page 17-220 – 17-262.<br />

For replacement parts, see page 17-262.<br />

For dimensions, see page 17-281.<br />

For wiring diagrams, see page 17-284 – 17-290.<br />

Coil Selection (●) a<br />

Nominal Voltage<br />

Code<br />

24 VAC 50/60 Hz 1<br />

24 VDC 2<br />

110/120 VAC 50/60 Hz 3<br />

208 VAC 50/60 Hz 4<br />

220/240 VAC 50/60 Hz 5<br />

277 VAC 60 Hz 6<br />

480 VAC 60 Hz 7<br />

600 VAC 60 Hz 8<br />

Non-Reversing Starter, Single Phase, 2-Pole, Thermal Overload Relay, Standard Enclosure<br />

1-Phase Motor Hp<br />

Rating per UL<br />

NEMA Type Enclosure (Standard Size)<br />

Type 1<br />

General Purpose,<br />

Indoor only<br />

Type 3/3R/4/12<br />

Weatherproof, Watertight,<br />

Dust-tight<br />

Type 4X 304 Stain. Steel<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

Unused<br />

Auxiliary<br />

Contacts<br />

Frame<br />

Size<br />

Contactor<br />

(for ref. only)<br />

115 V 208 V 230 V Catalog Number Catalog Number Catalog Number NO NC<br />

0.25 0.5 0.75 3RE4111–5AA●1–♦♦Y0 3RE4111–5CA●1–♦♦Y0 3RE4111–5EA●1–♦♦Y0 1 0 S00 3RT2015<br />

1 1 1 3RE4112–3AA●1–♦♦Y0 3RE4112–3CA●1–♦♦Y0 3RE4112–3EA●1–♦♦Y0 1 1 S0 3RT2023<br />

1 2 2 3RE4112–4AA●1–♦♦Y0 3RE4112–4CA●1–♦♦Y0 3RE4112–4EA●1–♦♦Y0 1 1 S0 3RT2024<br />

1 2 3 3RE4112–5AA●1–♦♦Y0 3RE4112–5CA●1–♦♦Y0 3RE4112–5EA●1–♦♦Y0 1 1 S0 3RT2025<br />

2 3 3 3RE4112–6AA●1–♦♦Y0 3RE4112–6CA●1–♦♦Y0 3RE4112–6EA●1–♦♦Y0 1 1 S0 3RT2026<br />

2 5 5 3RE4112–7AA●1–♦♦Y0 3RE4112–7CA●1–♦♦Y0 3RE4112–7EA●1–♦♦Y0 1 1 S0 3RT2027<br />

3 5 5 3RE4112–8AA●1–♦♦Y0 3RE4112–8CA●1–♦♦Y0 3RE4112–8EA●1–♦♦Y0 1 1 S0 3RT2028<br />

3 5 7.5 3RE4113–5AA●1–♦♦Y0 3RE4113–5CA●1–♦♦Y0 3RE4113–5EA●1–♦♦Y0 1 1 S2 3RT2035<br />

3 7 10 3RE4113–6AA●1–♦♦Y0 3RE4113–6CA●1–♦♦Y0 3RE4113–6EA●1–♦♦Y0 1 1 S2 3RT2036<br />

5 10 10 3RE4113–7AA●1–♦♦Y0 3RE4113–7CA●1–♦♦Y0 3RE4113–7EA●1–♦♦Y0 1 1 S2 3RT2037<br />

5 10 15 3RE4113–8AA●1–♦♦Y0 3RE4113–8CA●1–♦♦Y0 3RE4113–8EA●1–♦♦Y0 1 1 S2 3RT2038<br />

Non-Reversing Starter, Single Phase, 2-Pole, Thermal Overload Relay, Large Enclosure<br />

1-Phase Motor Hp<br />

Rating per UL<br />

NEMA Type Enclosure (Large Size)<br />

Type 1<br />

General Purpose,<br />

Indoor only<br />

Type 3/3R/4/12<br />

Weatherproof, Watertight,<br />

Dust-tight<br />

Type 4X 304 Stain. Steel<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

Unused<br />

Auxiliary<br />

Contacts<br />

Frame<br />

Size<br />

Contactor<br />

(for ref. only)<br />

115 V 208 V 230 V Catalog Number Catalog Number Catalog Number NO NC<br />

0.25 0.5 0.75 3RE4111–5BA●1–♦♦Y0<br />

1 0 S00 3RT2015<br />

1 1 1 3RE4112–3BA●1–♦♦Y0 1 1 S0 3RT2023<br />

1 2 2 3RE4112–4BA●1–♦♦Y0 1 1 S0 3RT2024<br />

Not applicable — Standard enclosure includes<br />

1 2 3 3RE4112–5BA●1–♦♦Y0 1 1 S0 3RT2025<br />

extra mounting space for accessories.<br />

2 3 3 3RE4112–6BA●1–♦♦Y0 1 1 S0 3RT2026<br />

2 5 5 3RE4112–7BA●1–♦♦Y0 1 1 S0 3RT2027<br />

3 5 5 3RE4112–8BA●1–♦♦Y0 1 1 S0 3RT2028<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

a For 3-phase controllers, 208 - 600 V coils will be wired<br />

for incoming voltage. 24 and120 V coils will be wired<br />

as separate source or control power transformer<br />

secondary (if ordered). For single phase controllers,<br />

120 and 240 V coils will be wired for incoming voltage.<br />

24 V coils will be wired as separate source or control<br />

power transformer secondary (if ordered). 277 - 600 V<br />

coils do not apply.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-179


Enclosed IEC Controls<br />

3RE4 Reversing Starter, 3-Phase, 3-Pole, Thermal or Solid-State Overload Relay<br />

Revised on 05/31/19<br />

Selection<br />

Ordering Information<br />

Replace the (●) with the code from the coil<br />

table on this page.<br />

Replace the () with the overload relay<br />

(OLR) code from this page.<br />

Replace the (♦♦) with the OLR current<br />

adjustment range from pg. 17-216.<br />

For factory modifications,<br />

see page 17-217 – 17-218.<br />

For accessories, see page 17-220 – 17-262.<br />

For replacement parts, see page 17-262.<br />

For dimensions, see page 17-281.<br />

For wiring diagrams, see page 17-284 – 17-290.<br />

Coil Selection (●) a<br />

Nominal Voltage<br />

Code<br />

24 VAC 50/60 Hz 1<br />

24 VDC 2<br />

110/120 VAC 50/60 Hz 3<br />

208 VAC 50/60 Hz 4<br />

220/240 VAC 50/60 Hz 5<br />

277 VAC 60 Hz 6<br />

480 VAC 60 Hz 7<br />

600 VAC 60 Hz 8<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Reversing Starter, 3-Phase, 3-Pole, Thermal or Solid-State Overload Relay, Standard Enclosure<br />

3-Phase Motor Hp Rating per UL<br />

NEMA Type Enclosure (Standard Size)<br />

Type 1<br />

General Purpose,<br />

Indoor only<br />

Type 3/3R/4/12<br />

Weatherproof, Watertight,<br />

Dust-tight<br />

Type 4X 304 Stain. Steel<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

Unused<br />

Auxiliary<br />

Contacts<br />

Frame<br />

Size<br />

Contactor<br />

(for ref. only)<br />

208 V 230 V 460 V 575 V Catalog Number Catalog Number Catalog Number NO NC<br />

1.5 2 3 5 3RE4141–5AA●–♦♦Y0 3RE4141–5CA●–♦♦Y0 3RE4141–5EA●–♦♦Y0 2 2 S00 3RA2315<br />

2 3 5 7.5 3RE4142–3AA●–♦♦Y0 3RE4142–3CA●–♦♦Y0 3RE4142–3EA●–♦♦Y0 2 0 S0 3RA2323<br />

3 3 7.5 10 3RE4142–4AA●–♦♦Y0 3RE4142–4CA●–♦♦Y0 3RE4142–4EA●–♦♦Y0 2 0 S0 3RA2324<br />

5 5 10 15 3RE4142–5AA●–♦♦Y0 3RE4142–5CA●–♦♦Y0 3RE4142–5EA●–♦♦Y0 2 0 S0 3RA2325<br />

7.5 7.5 15 20 3RE4142–6AA●–♦♦Y0 3RE4142–6CA●–♦♦Y0 3RE4142–6EA●–♦♦Y0 2 0 S0 3RA2326<br />

10 10 20 25 3RE4142–7AA●–♦♦Y0 3RE4142–7CA●–♦♦Y0 3RE4142–7EA●–♦♦Y0 2 0 S0 3RA2327<br />

10 10 25 25 3RE4142–8AA●–♦♦Y0 3RE4142–8CA●–♦♦Y0 3RE4142–8EA●–♦♦Y0 2 0 S0 3RA2328<br />

10 15 30 40 3RE4143–5AA●–♦♦Y0 3RE4143–5CA●–♦♦Y0 3RE4143–5EA●–♦♦Y0 2 0 S2 3RA2335<br />

15 15 40 50 3RE4143–6AA●–♦♦Y0 3RE4143–6CA●–♦♦Y0 3RE4143–6EA●–♦♦Y0 2 0 S2 3RA2336<br />

20 20 50 50 3RE4143–7AA●–♦♦Y0 3RE4143–7CA●–♦♦Y0 3RE4143–7EA●–♦♦Y0 2 0 S2 3RA2337<br />

20 25 50 60 3RE4143–8AA●–♦♦Y0 3RE4143–8CA●–♦♦Y0 3RE4143–8EA●–♦♦Y0 2 0 S2 3RA2338<br />

<br />

Thermal overload relay Class 10 = 1<br />

Solid-state overload relay selectable Class = 5<br />

Reversing Starter, 3-Phase, 3-Pole, Thermal or Solid-State Overload Relay, Large Enclosure<br />

3-Phase Motor Hp Rating per UL<br />

NEMA Type Enclosure (Large Size)<br />

Type 1<br />

General Purpose,<br />

Indoor only<br />

<br />

1<br />

5<br />

Type 3/3R/4/12<br />

Weatherproof, Watertight,<br />

Dust-tight<br />

<br />

1<br />

5<br />

Type 4X 304 Stain. Steel<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

Unused<br />

Auxiliary<br />

Contacts<br />

Frame<br />

Size<br />

Contactor<br />

(for ref. only)<br />

208 V 230 V 460 V 575 V Catalog Number Catalog Number Catalog Number NO NC<br />

1.5 2 3 5 3RE4141–5BA●–♦♦Y0<br />

2 2 S00 3RA2315<br />

2 3 5 7.5 3RE4142–3BA●–♦♦Y0 2 0 S0 3RA2323<br />

3 3 7.5 10 3RE4142–4BA●–♦♦Y0 2 0 S0 3RA2324<br />

5 5 10 15 3RE4142–5BA●–♦♦Y0<br />

Not applicable — Standard enclosure includes<br />

2 0 S0 3RA2325<br />

extra mounting space for accessories.<br />

7.5 7.5 15 20 3RE4142–6BA●–♦♦Y0 2 0 S0 3RA2326<br />

10 10 20 25 3RE4142–7BA●–♦♦Y0 2 0 S0 3RA2327<br />

10 10 25 25 3RE4142–8BA●–♦♦Y0 2 0 S0 3RA2328<br />

<br />

Thermal overload relay Class 10 = 1<br />

Solid-state overload relay selectable Class = 5<br />

a For 3-phase controllers, 208 - 600 V coils will be wired<br />

for incoming voltage. 24 and120 V coils will be wired<br />

as separate source or control power transformer<br />

secondary (if ordered). For single phase controllers,<br />

120 and 240 V coils will be wired for incoming voltage.<br />

24 V coils will be wired as separate source or control<br />

power transformer secondary (if ordered). 277 - 600 V<br />

coils do not apply.<br />

17-180<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Enclosed IEC Controls<br />

3RE4 Non-Reversing Contactor, 3-Pole (for both 1-Phase and 3-Phase)<br />

Revised on 05/31/19<br />

Selection<br />

Ordering Information<br />

Replace the (●) with the code from the coil<br />

table on this page.<br />

For factory modifications,<br />

see page 17-217 – 17-218.<br />

For accessories, see page 17-220 – 17-262.<br />

For replacement parts, see page 17-262.<br />

For dimensions, see page 17-281.<br />

For wiring diagrams, see page 17-284 – 17-290.<br />

Coil Selection (●) a<br />

Nominal Voltage<br />

Code<br />

24 VAC 50/60 Hz 1<br />

24 VDC 2<br />

110/120 VAC 50/60 Hz 3<br />

208 VAC 50/60 Hz 4<br />

220/240 VAC 50/60 Hz 5<br />

277 VAC 60 Hz 6<br />

480 VAC 60 Hz 7<br />

600 VAC 60 Hz 8<br />

Non-Reversing Contactor, 3-Pole (for both 1-Phase and 3-Phase), Standard Enclosure<br />

1-Phase Motor Hp<br />

Rating per UL<br />

3-Phase Motor Hp<br />

Rating per UL<br />

NEMA Type Enclosure (Standard Size)<br />

Type 1<br />

General Purpose,<br />

Indoor only<br />

Type 3/3R/4/12<br />

Weatherproof,<br />

Watertight, Dust-tight<br />

Type 4X 304 Stain. Steel<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

Unused<br />

Auxiliary<br />

Contacts Frame<br />

Size<br />

Contactor<br />

(for ref.<br />

only)<br />

115V 208V 230V 208V 230V 460V 575V Catalog Number Catalog Number Catalog Number NO NC<br />

0.25 0.5 0.75 1.5 2 3 5 3RE4161–5AA●0–0YY0 3RE4161–5CA●0–0YY0 3RE4161–5EA●0–0YY0 1 0 S00 3RT2015<br />

1 1 1 2 3 5 7.5 3RE4162–3AA●0–0YY0 3RE4162–3CA●0–0YY0 3RE4162–3EA●0–0YY0 1 1 S0 3RT2023<br />

1 2 2 3 3 7.5 10 3RE4162–4AA●0–0YY0 3RE4162–4CA●0–0YY0 3RE4162–4EA●0–0YY0 1 1 S0 3RT2024<br />

1 2 3 5 5 10 15 3RE4162–5AA●0–0YY0 3RE4162–5CA●0–0YY0 3RE4162–5EA●0–0YY0 1 1 S0 3RT2025<br />

2 3 3 7.5 7.5 15 20 3RE4162–6AA●0–0YY0 3RE4162–6CA●0–0YY0 3RE4162–6EA●0–0YY0 1 1 S0 3RT2026<br />

2 5 5 10 10 20 25 3RE4162–7AA●0–0YY0 3RE4162–7CA●0–0YY0 3RE4162–7EA●0–0YY0 1 1 S0 3RT2027<br />

3 5 5 10 10 25 25 3RE4162–8AA●0–0YY0 3RE4162–8CA●0–0YY0 3RE4162–8EA●0–0YY0 1 1 S0 3RT2028<br />

3 5 7.5 10 15 30 40 3RE4163–5AA●0–0YY0 3RE4163–5CA●0–0YY0 3RE4163–5EA●0–0YY0 1 1 S2 3RT2035<br />

3 7 10 15 15 40 50 3RE4163–6AA●0–0YY0 3RE4163–6CA●0–0YY0 3RE4163–6EA●0–0YY0 1 1 S2 3RT2036<br />

5 10 10 20 20 50 50 3RE4163–7AA●0–0YY0 3RE4163–7CA●0–0YY0 3RE4163–7EA●0–0YY0 1 1 S2 3RT2037<br />

5 10 15 20 25 50 60 3RE4163–8AA●0–0YY0 3RE4163–8CA●0–0YY0 3RE4163–8EA●0–0YY0 1 1 S2 3RT2038<br />

Non-Reversing Contactor, 3-Pole (for both 1-Phase and 3-Phase), Large Enclosure<br />

1-Phase Motor Hp<br />

Rating per UL<br />

3-Phase Motor Hp<br />

Rating per UL<br />

NEMA Type Enclosure (Large Size)<br />

Type 1<br />

General Purpose,<br />

Indoor only<br />

Type 3/3R/4/12<br />

Weatherproof,<br />

Watertight, Dust-tight<br />

Type 4X 304 Stain. Steel<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

Unused<br />

Auxiliary<br />

Contacts<br />

Frame<br />

Size<br />

Contactor<br />

(for ref.<br />

only)<br />

115V 208V 230V 208V 230V 460V 575V Catalog Number Catalog Number Catalog Number NO NC<br />

0.25 0.5 0.75 1.5 2 3 5 3RE4161–5BA●0–0YY0<br />

1 0 S00 3RT2015<br />

1 1 1 2 3 5 7.5 3RE4162–3BA●0–0YY0 1 1 S0 3RT2023<br />

1 2 2 3 3 7.5 10 3RE4162–4BA●0–0YY0 1 1 S0 3RT2024<br />

1 2 3 5 5 10 15 3RE4162–5BA●0–0YY0<br />

Not applicable — Standard enclosure includes<br />

1 1 S0 3RT2025<br />

extra mounting space for accessories.<br />

2 3 3 7.5 7.5 15 20 3RE4162–6BA●0–0YY0 1 1 S0 3RT2026<br />

2 5 5 10 10 20 25 3RE4162–7BA●0–0YY0 1 1 S0 3RT2027<br />

3 5 5 10 10 25 25 3RE4162–8BA●0–0YY0 1 1 S0 3RT2028<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

a For 3-phase controllers, 208 - 600 V coils will be wired<br />

for incoming voltage. 24 and120 V coils will be wired<br />

as separate source or control power transformer<br />

secondary (if ordered). For single phase controllers,<br />

120 and 240 V coils will be wired for incoming voltage.<br />

24 V coils will be wired as separate source or control<br />

power transformer secondary (if ordered). 277 - 600 V<br />

coils do not apply.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-181


Enclosed IEC Controls<br />

3RE4 Reversing Contactor, 3-Pole (for both 1-Phase and 3-Phase)<br />

Revised on 05/31/19<br />

Selection<br />

Ordering Information<br />

Replace the (●) with the code from the coil<br />

table on this page.<br />

For factory modifications,<br />

see page 17-217 – 17-218.<br />

For accessories, see page 17-220 – 17-262.<br />

For replacement parts, see page 17-262.<br />

For dimensions, see page 17-281.<br />

For wiring diagrams, see page 17-284 – 17-290.<br />

Coil Selection (●) a<br />

Nominal Voltage<br />

Code<br />

24 VAC 50/60 Hz 1<br />

24 VDC 2<br />

110/120 VAC 50/60 Hz 3<br />

208 VAC 50/60 Hz 4<br />

220/240 VAC 50/60 Hz 5<br />

277 VAC 60 Hz 6<br />

480 VAC 60 Hz 7<br />

600 VAC 60 Hz 8<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Reversing Contactor, 3-Pole (for both 1-Phase and 3-Phase), Standard Enclosure<br />

1-Phase<br />

Motor Hp<br />

Rating per UL<br />

3-Phase<br />

Motor Hp<br />

Rating per UL<br />

NEMA Type Enclosure (Standard Size)<br />

Type 1<br />

General Purpose,<br />

Indoor only<br />

Type 3/3R/4/12<br />

Weatherproof,<br />

Watertight, Dust-tight<br />

Type 4X 304 Stain. Steel<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

Unused<br />

Auxiliary<br />

Contacts<br />

Frame<br />

Size<br />

Contactor<br />

(for ref.<br />

only)<br />

115V 230V 208V 230V 460V 575V Catalog Number Catalog Number Catalog Number NO NC<br />

0.25 0.75 1.5 2 3 5 3RE4181–5AA●0–0YY0 3RE4181–5CA●0–0YY0 3RE4181–5EA●0–0YY0 2 2 S00 3RA2315<br />

1 1 2 3 5 7.5 3RE4182–3AA●0–0YY0 3RE4182–3CA●0–0YY0 3RE4182–3EA●0–0YY0 2 0 S0 3RA2323<br />

1 2 3 3 7.5 10 3RE4182–4AA●0–0YY0 3RE4182–4CA●0–0YY0 3RE4182–4EA●0–0YY0 2 0 S0 3RA2324<br />

1 3 5 5 10 15 3RE4182–5AA●0–0YY0 3RE4182–5CA●0–0YY0 3RE4182–5EA●0–0YY0 2 0 S0 3RA2325<br />

2 3 7.5 7.5 15 20 3RE4182–6AA●0–0YY0 3RE4182–6CA●0–0YY0 3RE4182–6EA●0–0YY0 2 0 S0 3RA2326<br />

2 5 10 10 20 25 3RE4182–7AA●0–0YY0 3RE4182–7CA●0–0YY0 3RE4182–7EA●0–0YY0 2 0 S0 3RA2327<br />

3 5 10 10 25 25 3RE4182–8AA●0–0YY0 3RE4182–8CA●0–0YY0 3RE4182–8EA●0–0YY0 2 0 S0 3RA2328<br />

3 7.5 10 15 30 40 3RE4183–5AA●0–0YY0 3RE4183–5CA●0–0YY0 3RE4183–5EA●0–0YY0 2 0 S2 3RA2335<br />

3 10 15 15 40 50 3RE4183–6AA●0–0YY0 3RE4183–6CA●0–0YY0 3RE4183–6EA●0–0YY0 2 0 S2 3RA2336<br />

5 10 20 20 50 50 3RE4183–7AA●0–0YY0 3RE4183–7CA●0–0YY0 3RE4183–7EA●0–0YY0 2 0 S2 3RA2337<br />

5 15 20 25 50 60 3RE4183–8AA●0–0YY0 3RE4183–8CA●0–0YY0 3RE4183–8EA●0–0YY0 2 0 S2 3RA2338<br />

Reversing Contactor, 3-Pole (for both 1-Phase and 3-Phase), Large Enclosure<br />

1-Phase<br />

Motor Hp<br />

Rating per UL<br />

3-Phase<br />

Motor Hp<br />

Rating per UL<br />

NEMA Type Enclosure (Large Size)<br />

Type 1<br />

General Purpose,<br />

Indoor only<br />

Type 3/3R/4/12<br />

Weatherproof,<br />

Watertight, Dust-tight<br />

Type 4X 304 Stain. Steel<br />

Watertight, Dust-tight,<br />

Corrosion Resistant<br />

Unused<br />

Auxiliary<br />

Contacts<br />

Frame<br />

Size<br />

Contactor<br />

(for ref.<br />

only)<br />

115V 230V 208V 230V 460V 575V Catalog Number Catalog Number Catalog Number NO NC<br />

0.25 0.75 1.5 2 3 5 3RE4181–5BA●0–0YY0<br />

2 2 S00 3RA2315<br />

1 1 2 3 5 7.5 3RE4182–3BA●0–0YY0 2 0 S0 3RA2323<br />

1 2 3 3 7.5 10 3RE4182–4BA●0–0YY0 2 0 S0 3RA2324<br />

1 3 5 5 10 15 3RE4182–5BA●0–0YY0<br />

Not applicable — Standard enclosure includes<br />

2 0 S0 3RA2325<br />

extra mounting space for accessories.<br />

2 3 7.5 7.5 15 20 3RE4182–6BA●0–0YY0 2 0 S0 3RA2326<br />

2 5 10 10 20 25 3RE4182–7BA●0–0YY0 2 0 S0 3RA2327<br />

3 5 10 10 25 25 3RE4182–8BA●0–0YY0 2 0 S0 3RA2328<br />

a For 3-phase controllers, 208 - 600 V coils will be wired<br />

for incoming voltage. 24 and120 V coils will be wired<br />

as separate source or control power transformer<br />

secondary (if ordered). For single phase controllers,<br />

120 and 240 V coils will be wired for incoming voltage.<br />

24 V coils will be wired as separate source or control<br />

power transformer secondary (if ordered). 277 - 600 V<br />

coils do not apply.<br />

17-182<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Enclosed IEC Controls<br />

Selection Tables for 3RE4 Overload Relays<br />

Selection Tables for 3RE4 Overload Relays<br />

Revised on 05/31/19<br />

Selection<br />

Selection Information<br />

Replace the (♦♦) within the incomplete<br />

3RE4 catalog number with a<br />

code selected from the tables below.<br />

The frame size must match that<br />

of the 3RE4 product.<br />

Thermal<br />

Overload Relay<br />

Solid-State<br />

Overload Relay<br />

Thermal Overload Relays, Trip Class 10, Single and Three Phase<br />

Features and technical characteristics:<br />

n Phase failure sensitivity<br />

n Includes NC trip contact and NO<br />

alarm contact<br />

n Manual and automatic RESET (selectable)<br />

n Switch position indicator<br />

n TEST function<br />

n STOP button<br />

n Sealable cover (optional)<br />

n Screw-type terminals<br />

Soft Starter<br />

Control<br />

Current<br />

Adjustment<br />

Range (Amp)<br />

Thermal<br />

Overload Relay<br />

(reference only)<br />

Code<br />

♦♦<br />

Frame Size S00<br />

0.7 - 1 0J 3RU2116-0JB0<br />

0.9 - 1.25 0K 3RU2116-0KB0<br />

1.1 - 1.6 1A 3RU2116-1AB0<br />

1.4 - 2 1B 3RU2116-1BB0<br />

1.8 - 2.5 1C 3RU2116-1CB0<br />

2.2 - 3.2 1D 3RU2116-1DB0<br />

2.8 - 4 1E 3RU2116-1EB0<br />

3.5 - 5 1F 3RU2116-1FB0<br />

4.5 - 6.3 1G 3RU2116-1GB0<br />

5.5 - 8 1H 3RU2116-1HB0<br />

7 - 10 1J 3RU2116-1JB0<br />

9 - 12.5 1K 3RU2116-1KB0<br />

11 - 16 4A 3RU2116-4AB0<br />

Current<br />

Adjustment<br />

Range (Amp)<br />

Thermal<br />

Overload Relay<br />

(reference only)<br />

Code<br />

♦♦<br />

Frame Size S0<br />

1.8 - 2.5 1C 3RU2126-1CB0<br />

2.2 - 3.2 1D 3RU2126-1DB0<br />

2.8 - 4 1E 3RU2126-1EB0<br />

3.5 - 5 1F 3RU2126-1FB0<br />

4.5 - 6.3 1G 3RU2126-1GB0<br />

5.5 - 8 1H 3RU2126-1HB0<br />

7 - 10 1J 3RU2126-1JB0<br />

9 - 12.5 1K 3RU2126-1KB0<br />

11 - 16 4A 3RU2126-4AB0<br />

14 - 20 4B 3RU2126-4BB0<br />

17 - 22 4C 3RU2126-4CB0<br />

20 - 25 4D 3RU2126-4DB0<br />

23 - 28 4N 3RU2126-4NB0<br />

27 - 32 4E 3RU2126-4EB0<br />

30 - 36 4P 3RU2126-4PB0<br />

34 - 40 4F 3RU2126-4FB0<br />

Current<br />

Adjustment<br />

Range (Amp)<br />

Thermal<br />

Overload Relay<br />

(reference only)<br />

Code<br />

♦♦<br />

Frame Size S2<br />

22 - 32 4E 3RU2136-4EB0<br />

28 - 40 4F 3RU2136-4FB0<br />

36 - 45 4G 3RU2136-4GB0<br />

40 - 50 4H 3RU2136-4HB0<br />

47 - 57 4Q 3RU2136-4QB0<br />

54 - 65 4J 3RU2136-4JB0<br />

62 - 73 4K 3RU2136-4KB0<br />

70 - 80 4R 3RU2136-4RB0<br />

17 CONTROL<br />

PRODUCTS<br />

Solid-State Overload Relays, Selectable Trip Class 5, 10, 20 and 30, Three Phase Only<br />

Features and technical characteristics:<br />

n Overload, phase failure and unbalance<br />

protection<br />

n Internal ground fault detection (selectable)<br />

n Internal power supply<br />

n Includes NC trip contact and NO alarm<br />

contact<br />

n Manual and automatic RESET (selectable)<br />

n Electrical remote RESET integrated<br />

n Switch position indicator<br />

n TEST function and self-monitoring<br />

n Sealable cover (optional)<br />

n Screw-type terminals<br />

Current<br />

Adjustment<br />

Range (Amp)<br />

Solid-State<br />

Overload Relay<br />

(reference only)<br />

Code<br />

♦♦<br />

Frame Size S00<br />

0.32 - 1.25 4N 3RB3113-4NB0<br />

1 - 4 4P 3RB3113-4PB0<br />

3 - 12 4S 3RB3113-4SB0<br />

4 - 16 4T 3RB3113-4TB0<br />

Current<br />

Adjustment<br />

Range (Amp)<br />

Solid-State<br />

Overload Relay<br />

(reference only)<br />

Code<br />

♦♦<br />

Frame Size S0<br />

0.32 - 1.25 4N 3RB3123-4NB0<br />

1 - 4 4P 3RB3123-4PB0<br />

3 - 12 4S 3RB3123-4SB0<br />

6 - 25 4Q 3RB3123-4QB0<br />

10 - 40 4V 3RB3123-4VB0<br />

Current<br />

Adjustment<br />

Range (Amp)<br />

Solid-State<br />

Overload Relay<br />

(reference only)<br />

Code<br />

♦♦<br />

Frame Size S2<br />

12 - 50 4U 3RB3133-4UB0<br />

20 - 80 4W 3RB3133-4WB0<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-183


Enclosed IEC Controls<br />

3RE4 Factory Modifications<br />

Revised on 05/31/19<br />

Selection<br />

Selection Information<br />

These tables apply to 3RE4 products.<br />

Replace the last two characters of the<br />

3RE4 catalog number (Y0), with a code selected<br />

from the tables below.<br />

Soft Starter<br />

Control<br />

Start-Stop Push Button Combinations<br />

Description Code (Y0) Restrictions<br />

(No modifications included) Y0 —<br />

Start-Stop Push Buttons B0 1<br />

Start-Stop Push Buttons, Red On Pilot Light B1 1<br />

Start-Stop Push Buttons, Red On Pilot Light, Green Off Pilot Light B2 1<br />

Start-Stop Push Buttons, CPT Std Capacity a 208:120V B3 1, 2 and 4<br />

Start-Stop Push Buttons, CPT Std Capacity a 208:120V, Red On Pilot Light B4 1, 2 and 4<br />

Start-Stop Push Buttons, CPT Std Capacity a 208:120V, Red On Pilot Light, Green Off Pilot Light B5 1, 2 and 4<br />

Start-Stop Push Buttons, CPT Std Capacity a 208:24V B6 1, 3 and 4<br />

Start-Stop Push Buttons, CPT Std Capacity a 208:24V, Red On Pilot Light B7 1, 3 and 4<br />

Start-Stop Push Buttons, CPT Std Capacity a 208:24V, Red On Pilot Light, Green Off Pilot Light B8 1, 3 and 4<br />

Start-Stop Push Buttons, CPT Std Capacity a 240:120V C0 1 and 2<br />

Start-Stop Push Buttons, CPT Std Capacity a 240:120V, Red On Pilot Light C1 1 and 2<br />

Start-Stop Push Buttons, CPT Std Capacity a 240:120V, Red On Pilot Light, Green Off Pilot Light C2 1 and 2<br />

Start-Stop Push Buttons, CPT Std Capacity a 240:24V C3 1 and 3<br />

Start-Stop Push Buttons, CPT Std Capacity a 240:24V, Red On Pilot Light C4 1 and 3<br />

Start-Stop Push Buttons, CPT Std Capacity a 240:24V, Red On Pilot Light, Green Off Pilot Light C5 1 and 3<br />

Start-Stop Push Buttons, CPT Std Capacity a 480/240:120V C6 1, 2 and 4<br />

Start-Stop Push Buttons, CPT Std Capacity a 480/240:120V, Red On Pilot Light C7 1, 2 and 4<br />

Start-Stop Push Buttons, CPT Std Capacity a 480/240:120V, Red On Pilot Light, Green Off Pilot Light C8 1, 2 and 4<br />

Start-Stop Push Buttons, CPT Std Capacity a 480/240:24V D0 1, 3 and 4<br />

Start-Stop Push Buttons, CPT Std Capacity a 480/240:24V, Red On Pilot Light D1 1, 3 and 4<br />

Start-Stop Push Buttons, CPT Std Capacity a 480/240:24V, Red On Pilot Light, Green Off Pilot Light D2 1, 3 and 4<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Fwd-Rev-Stop Push Button Combinations<br />

Description Code (Y0) Restrictions<br />

(No modifications included) Y0 —<br />

Fwd-Rev-Stop Push Buttons D3 5<br />

Fwd-Rev-Stop Push Buttons, Red On Pilot Light D4 5<br />

Fwd-Rev-Stop Push Buttons, Red On Pilot Light, Green Off Pilot Light D5 5<br />

Fwd-Rev-Stop Push Buttons, CPT Std Capacity a 208:120V D6 2, 4 and 5<br />

Fwd-Rev-Stop Push Buttons, CPT Std Capacity a 208:120V, Red On Pilot Light D7 2, 4 and 5<br />

Fwd-Rev-Stop Push Buttons, CPT Std Capacity a 208:120V, Red On Pilot Light, Green Off Pilot Light D8 2, 4 and 5<br />

Fwd-Rev-Stop Push Buttons, CPT Std Capacity a 208:24V E0 3, 4 and 5<br />

Fwd-Rev-Stop Push Buttons, CPT Std Capacity a 208:24V, Red On Pilot Light E1 3, 4 and 5<br />

Fwd-Rev-Stop Push Buttons, CPT Std Capacity a 208:24V, Red On Pilot Light, Green Off Pilot Light E2 3, 4 and 5<br />

Fwd-Rev-Stop Push Buttons, CPT Std Capacity a 240:120V E3 2 and 5<br />

Fwd-Rev-Stop Push Buttons, CPT Std Capacity a 240:120V, Red On Pilot Light E4 2 and 5<br />

Fwd-Rev-Stop Push Buttons, CPT Std Capacity a 240:120V, Red On Pilot Light, Green Off Pilot Light E5 2 and 5<br />

Fwd-Rev-Stop Push Buttons, CPT Std Capacity a 240:24V E6 3 and 5<br />

Fwd-Rev-Stop Push Buttons, CPT Std Capacity a 240:24V, Red On Pilot Light E7 3 and 5<br />

Fwd-Rev-Stop Push Buttons, CPT Std Capacity a 240:24V, Red On Pilot Light, Green Off Pilot Light E8 3 and 5<br />

Fwd-Rev-Stop Push Buttons, CPT Std Capacity a 480/240:120V F0 2, 4 and 5<br />

Fwd-Rev-Stop Push Buttons, CPT Std Capacity a 480/240:120V, Red On Pilot Light F1 2, 4 and 5<br />

Fwd-Rev-Stop Push Buttons, CPT Std Capacity a 480/240:120V, Red On Pilot Light, Green Off Pilot Light F2 2, 4 and 5<br />

Fwd-Rev-Stop Push Buttons, CPT Std Capacity a 480/240:24V F3 3, 4 and 5<br />

Fwd-Rev-Stop Push Buttons, CPT Std Capacity a 480/240:24V, Red On Pilot Light F4 3, 4 and 5<br />

Fwd-Rev-Stop Push Buttons, CPT Std Capacity a 480/240:24V, Red On Pilot Light, Green Off Pilot Light F5 3, 4 and 5<br />

a A CPT in a NEMA type 1 enclosure with a size S00 or S0 controller<br />

requires a large size enclosure. A CPT in a NEMA type 1 enclosure<br />

with a size S2 controller requires a standard size enclosure.<br />

All other enclosure types may be standard size.<br />

Restrictions:<br />

1. Valid only with non-reversing controllers.<br />

2. Valid only with 120 V coil.<br />

3. Valid only with 24 VAC coil.<br />

4. Not valid with single-phase controllers.<br />

5. Not valid in NEMA Type 1 enclosures.<br />

17-184<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Enclosed IEC Controls<br />

3RE4 Factory Modifications<br />

Revised on 05/31/19<br />

Selection<br />

Selection Information<br />

These tables apply to 3RE4 products.<br />

Replace the last two characters of the<br />

3RE4 catalog number (Y0), with a code selected<br />

from the tables below.<br />

Hand-Off-Auto Selector Switch Combinations<br />

Description Code (Y0) Restrictions<br />

(No modifications included) Y0 —<br />

Hand-Off-Auto Selector Switch F6 1<br />

Hand-Off-Auto Selector Switch, Red On Pilot Light F7 1<br />

Hand-Off-Auto Selector Switch, Red On Pilot Light, Green Off Pilot Light F8 1<br />

Hand-Off-Auto Selector Switch, CPT Std Capacity a 208:120V G0 1, 2 and 4<br />

Hand-Off-Auto Selector Switch, CPT Std Capacity a 208:120V, Red On Pilot Light G1 1, 2 and 4<br />

Hand-Off-Auto Selector Switch, CPT Std Capacity a 208:120V, Red On Pilot Light, Green Off Pilot Light G2 1, 2 and 4<br />

Hand-Off-Auto Selector Switch, CPT Std Capacity a 208:24V G3 1, 3 and 4<br />

Hand-Off-Auto Selector Switch, CPT Std Capacity a 208:24V, Red On Pilot Light G4 1, 3 and 4<br />

Hand-Off-Auto Selector Switch, CPT Std Capacity a 208:24V, Red On Pilot Light, Green Off Pilot Light G5 1, 3 and 4<br />

Hand-Off-Auto Selector Switch, CPT Std Capacity a 240:120V G6 1 and 2<br />

Hand-Off-Auto Selector Switch, CPT Std Capacity a 240:120V, Red On Pilot Light G7 1 and 2<br />

Hand-Off-Auto Selector Switch, CPT Std Capacity a 240:120V, Red On Pilot Light, Green Off Pilot Light G8 1 and 2<br />

Hand-Off-Auto Selector Switch, CPT Std Capacity a 240:24V H0 1 and 3<br />

Hand-Off-Auto Selector Switch, CPT Std Capacity a 240:24V, Red On Pilot Light H1 1 and 3<br />

Hand-Off-Auto Selector Switch, CPT Std Capacity a 240:24V, Red On Pilot Light, Green Off Pilot Light H2 1 and 3<br />

Hand-Off-Auto Selector Switch, CPT Std Capacity a 480/240:120V H3 1, 2 and 4<br />

Hand-Off-Auto Selector Switch, CPT Std Capacity a 480/240:120V, Red On Pilot Light H4 1, 2 and 4<br />

Hand-Off-Auto Selector Switch, CPT Std Capacity a 480/240:120V, Red On Pilot Light, Green Off Pilot Light H5 1, 2 and 4<br />

Hand-Off-Auto Selector Switch, CPT Std Capacity a 480/240:24V H6 1, 3 and 4<br />

Hand-Off-Auto Selector Switch, CPT Std Capacity a 480/240:24V, Red On Pilot Light H7 1, 3 and 4<br />

Hand-Off-Auto Selector Switch, CPT Std Capacity a 480/240:24V, Red On Pilot Light, Green Off Pilot Light H8 1, 3 and 4<br />

On-Off Selector Switch Combinations<br />

Description Code (Y0) Restrictions<br />

(No modifications included) Y0 —<br />

On-Off Selector Switch J0 1<br />

On-Off Selector Switch, Red On Pilot Light J1 1<br />

On-Off Selector Switch, Red On Pilot Light, Green Off Pilot Light J2 1<br />

On-Off Selector Switch, CPT Std Capacity a 208:120V J3 1, 2 and 4<br />

On-Off Selector Switch, CPT Std Capacity a 208:120V, Red On Pilot Light J4 1, 2 and 4<br />

On-Off Selector Switch, CPT Std Capacity a 208:120V, Red On Pilot Light, Green Off Pilot Light J5 1, 2 and 4<br />

On-Off Selector Switch, CPT Std Capacity a 208:24V J6 1, 3 and 4<br />

On-Off Selector Switch, CPT Std Capacity a 208:24V, Red On Pilot Light J7 1, 3 and 4<br />

On-Off Selector Switch, CPT Std Capacity a 208:24V, Red On Pilot Light, Green Off Pilot Light J8 1, 3 and 4<br />

On-Off Selector Switch, CPT Std Capacity a 240:120V K0 1 and 2<br />

On-Off Selector Switch, CPT Std Capacity a 240:120V, Red On Pilot Light K1 1 and 2<br />

On-Off Selector Switch, CPT Std Capacity a 240:120V, Red On Pilot Light, Green Off Pilot Light K2 1 and 2<br />

On-Off Selector Switch, CPT Std Capacity a 240:24V K3 1 and 3<br />

On-Off Selector Switch, CPT Std Capacity a 240:24V, Red On Pilot Light K4 1 and 3<br />

On-Off Selector Switch, CPT Std Capacity a 240:24V, Red On Pilot Light, Green Off Pilot Light K5 1 and 3<br />

On-Off Selector Switch, CPT Std Capacity a 480/240:120V K6 1, 2 and 4<br />

On-Off Selector Switch, CPT Std Capacity a 480/240:120V, Red On Pilot Light K7 1, 2 and 4<br />

On-Off Selector Switch, CPT Std Capacity a 480/240:120V, Red On Pilot Light, Green Off Pilot Light K8 1, 2 and 4<br />

On-Off Selector Switch, CPT Std Capacity a 480/240:24V L0 1, 3 and 4<br />

On-Off Selector Switch, CPT Std Capacity a 480/240:24V, Red On Pilot Light L1 1, 3 and 4<br />

On-Off Selector Switch, CPT Std Capacity a 480/240:24V, Red On Pilot Light, Green Off Pilot Light L2 1, 3 and 4<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

a A CPT in a NEMA type 1 enclosure with a size S00 or S0 controller<br />

requires a large size enclosure. A CPT in a NEMA type 1 enclosure<br />

with a size S2 controller requires a standard size enclosure.<br />

All other enclosure types may be standard size.<br />

Restrictions:<br />

1. Valid only with non-reversing controllers.<br />

2. Valid only with 120 V coil.<br />

3. Valid only with 24 VAC coil.<br />

4. Not valid with single-phase controllers.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-185


Enclosed IEC Controls<br />

3RE4 Factory Modifications<br />

Revised on 05/31/19<br />

Selection<br />

Selection Information<br />

These tables apply to 3RE4 products.<br />

Replace the last two characters of the<br />

3RE4 catalog number (Y0), with a code selected<br />

from the tables below.<br />

CONTROL<br />

PRODUCTS<br />

17<br />

Soft Starter<br />

Control<br />

Fwd-Off-Rev Selector Switch Combinations<br />

Description Code (Y0) Restrictions<br />

(No modifications included) Y0 —<br />

Fwd-Off-Rev Selector Switch L3 —<br />

Fwd-Off-Rev Selector Switch, Red On Pilot Light L4 —<br />

Fwd-Off-Rev Selector Switch, Red On Pilot Light, Green Off Pilot Light L5 —<br />

Fwd-Off-Rev Selector Switch, CPT Std Capacity a 208:120V L6 1 and 3<br />

Fwd-Off-Rev Selector Switch, CPT Std Capacity a 208:120V, Red On Pilot Light L7 1 and 3<br />

Fwd-Off-Rev Selector Switch, CPT Std Capacity a 208:120V, Red On Pilot Light, Green Off Pilot Light L8 1 and 3<br />

Fwd-Off-Rev Selector Switch, CPT Std Capacity a 208:24V M0 2 and 3<br />

Fwd-Off-Rev Selector Switch, CPT Std Capacity a 208:24V, Red On Pilot Light M1 2 and 3<br />

Fwd-Off-Rev Selector Switch, CPT Std Capacity a 208:24V, Red On Pilot Light, Green Off Pilot Light M2 2 and 3<br />

Fwd-Off-Rev Selector Switch, CPT Std Capacity a 240:120V M3 1<br />

Fwd-Off-Rev Selector Switch, CPT Std Capacity a 240:120V, Red On Pilot Light M4 1<br />

Fwd-Off-Rev Selector Switch, CPT Std Capacity a 240:120V, Red On Pilot Light, Green Off Pilot Light M5 1<br />

Fwd-Off-Rev Selector Switch, CPT Std Capacity a 240:24V M6 2<br />

Fwd-Off-Rev Selector Switch, CPT Std Capacity a 240:24V, Red On Pilot Light M7 2<br />

Fwd-Off-Rev Selector Switch, CPT Std Capacity a 240:24V, Red On Pilot Light, Green Off Pilot Light M8 2<br />

Fwd-Off-Rev Selector Switch, CPT Std Capacity a 480/240:120V N0 1 and 3<br />

Fwd-Off-Rev Selector Switch, CPT Std Capacity a 480/240:120V, Red On Pilot Light N1 1 and 3<br />

Fwd-Off-Rev Selector Switch, CPT Std Capacity a 480/240:120V, Red On Pilot Light, Green Off Pilot Light N2 1 and 3<br />

Fwd-Off-Rev Selector Switch, CPT Std Capacity a 480/240:24V N3 2 and 3<br />

Fwd-Off-Rev Selector Switch, CPT Std Capacity a 480/240:24V, Red On Pilot Light N4 2 and 3<br />

Fwd-Off-Rev Selector Switch, CPT Std Capacity a 480/240:24V, Red On Pilot Light, Green Off Pilot Light N5 2 and 3<br />

a A CPT in a NEMA type 1 enclosure with a size S00 or S0 controller<br />

requires a large size enclosure. A CPT in a NEMA type 1 enclosure<br />

with a size S2 controller requires a standard size enclosure.<br />

All other enclosure types may be standard size.<br />

Restrictions:<br />

1. Valid only with 120 V coil.<br />

2. Valid only with 24 VAC coil.<br />

3. Not valid with single-phase controllers.<br />

17-186<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Enclosed IEC Controls<br />

3RE4 Field Modifications and Accessories<br />

Revised on 05/31/19<br />

Selection<br />

Pilot Devices<br />

Device a<br />

Enclosure<br />

NEMA Type<br />

Catalog<br />

Number<br />

momentary b 3/3R/4/12 & 4X 49SDP05<br />

Start-Stop Push Buttons,<br />

1 49SDPB5<br />

49SDPB5<br />

49SDSBJ<br />

49SDSB4<br />

momentary b 3/3R/4/12 & 4X 49SDP02<br />

Fwd-Rev-Stop Push Buttons,<br />

1 NA<br />

1 49SDSBJ<br />

Hand-Off-Auto Selector Switch<br />

3/3R/4/12 & 4X<br />

49SDS01<br />

Start Push Button<br />

Stop Push Button<br />

On-Off Selector Switch<br />

1 49SDSB4<br />

3/3R/4/12 & 4X 49SDS04<br />

2-Position Selector Switch<br />

3-Position Selector Switch<br />

Fwd-Off-Rev Selector Switch<br />

1 49SDSBJ<br />

3/3R/4/12 & 4X<br />

49SDS02<br />

Soft Starter<br />

Control<br />

Pilot Lights<br />

Device a<br />

Enclosure<br />

NEMA Type<br />

Voltage<br />

Catalog<br />

Number<br />

Light module and lens color:<br />

RED, GREEN, and AMBER.<br />

Legends include:<br />

ON, RUN, OFF c , OLR TRIPPED d 1<br />

24 to 240 V AC/DC 49SDLBU<br />

277 V AC 49SDLBL<br />

Red FORWARD, Red REVERSE<br />

1<br />

3/3R/4/12 & 4X<br />

3/3R/4/12 & 4X<br />

24 to 240 V AC/DC 49SDLB7RU<br />

277 V AC 49SDLB7RL<br />

24 to 240 V AC/DC 49SDL07RU<br />

277 V AC 49SDL07RL<br />

Green FORWARD, Green REVERSE<br />

Red ON<br />

Red OFF c<br />

1<br />

3/3R/4/12 & 4X<br />

3/3R/4/12 & 4X<br />

3/3R/4/12 & 4X<br />

3/3R/4/12 & 4X<br />

3/3R/4/12 & 4X<br />

3/3R/4/12 & 4X<br />

24 to 240 V AC/DC 49SDLB7GU<br />

277 V AC 49SDLB7GL<br />

24 to 240 V AC/DC 49SDL07GU<br />

277 V AC 49SDL07GL<br />

24 to 240 V AC/DC 49SDL0BRU<br />

277 V AC 49SDL0BRL<br />

24 to 240 V AC/DC 49SDL0ARU<br />

277 V AC 49SDL0ARL<br />

17 CONTROL<br />

PRODUCTS<br />

Green ON<br />

3/3R/4/12 & 4X<br />

3/3R/4/12 & 4X<br />

24 to 240 V AC/DC 49SDL0BGU<br />

277 V AC 49SDL0BGL<br />

Green OFF c<br />

3/3R/4/12 & 4X<br />

3/3R/4/12 & 4X<br />

24 to 240 V AC/DC 49SDL0AGU<br />

277 V AC 49SDL0AGL<br />

Auxiliary Contacts<br />

Device Frame Size Catalog Number<br />

1 NO & 1 NC laterally mounted, S00<br />

3RH2911-1DA11<br />

screw terminals<br />

S0 and S2<br />

3RH2921-1DA11<br />

2 NO laterally mounted,<br />

S00<br />

NA<br />

screw terminals<br />

S0 and S2<br />

3RH2921-1DA20<br />

2 NC laterally mounted,<br />

S00<br />

3RH2911-1DA02<br />

screw terminals<br />

S0 and S2<br />

3RH2921-1DA02<br />

a 3SU 22 mm devices. Pilot lights include LED bulbs.<br />

b Each contactor must have a normally open (NO)<br />

auxiliary contact available for seal-in circuit. Order<br />

separately as needed.<br />

c To use as an OFF indicator, the contactor must have a<br />

normally closed (NC) auxiliary contact available for the<br />

circuit. Order separately as needed.<br />

d To use as an overload relay (OLR) trip indicator, the<br />

OLR must have a normally open (NO) auxiliary contact<br />

available for the circuit.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-187


Enclosed IEC Controls<br />

3RE4 Field Modifications, Accessories, and Replacement Parts<br />

Revised on 05/31/19<br />

Selection<br />

Control Power Transformers a<br />

Device<br />

Frame Size<br />

Catalog<br />

Number<br />

Transformer Table<br />

Primary Volts Secondary Volts Code<br />

45 VA, 1-secondary fuse S00 KT*050 120 24 1<br />

75 VA, 2-primary and 1-secondary fuses S0 & S2 KT*075 208 24 G<br />

208 120 H<br />

240/480 24 4<br />

240/480 120 8<br />

Replace * with code from Transformer Table.<br />

277 24 5<br />

45VA CPT does not require primary fuses per NEC.<br />

277 120 7<br />

600 24 6<br />

600 120 9<br />

Soft Starter<br />

Control<br />

Control Relays and Timers ab Catalog<br />

Coil Voltage Table<br />

Device<br />

Number<br />

Voltage<br />

Code<br />

Control relay, 4 NO / 0 NC 3RH2140-1●●●0 24 VAC 50/60 Hz AB0<br />

Control relay, 3 NO / 1 NC 3RH2131-1●●●0 24 VDC BB4<br />

Control relay, 2 NO / 2 NC 3RH2122-1●●●0 110/120 VAC 50/60 Hz AK6<br />

ON-delay timer, 0.05 sec. – 100 hr., 24 – 240V AC/DC 3RP2525-1BW30 208 VAC 50/60 Hz AM2<br />

OFF-delay timer, 0.05 sec. – 100 hr., 24 – 240V AC/DC 3RP2535-1AW30 220/240 VAC 50/60 Hz AP6<br />

277 VAC 60 Hz —<br />

Replace ●●● with code from Coil Voltage Table.<br />

480 VAC 60 Hz AV6<br />

Relays and timers include screw terminals.<br />

Relay Timer<br />

600 VAC 60 Hz —<br />

Miscellaneous<br />

Device<br />

1-pole fuse block for control circuit, 600V / 30A, DIN rail mounted, CC fuses (not included)<br />

2-pole fuse block for control circuit, 600V / 30A, DIN rail mounted, CC fuses (not included)<br />

Ground Lug, 3 Conductor, 2-14 AWG AL/CU Wire<br />

Catalog Number<br />

3NW7513-0HG<br />

3NW7523-0HG<br />

75D28182001<br />

17<br />

CONTROL<br />

PRODUCTS<br />

3NW7513-0HG 8WA1808<br />

8WA10111DF11 MTR5<br />

Replacement Parts<br />

Terminal block, 1-point unwired, DIN rail mounted, 6mm, 26A b<br />

8WA10111DF11<br />

End retainer for DIN rail b<br />

8WA1808<br />

DIN rail kit, 35mm x 5 in, for mounting optional accessories a<br />

MTR5<br />

Sealable cover for rotary dial on overload relay (10 per package) 3RV29 08-0P<br />

Enclosure Kits<br />

Device<br />

Contactor parts (Obtain Cat. No. from device and refer to Industrial Control Catalog). —<br />

Overload relay (Obtain Cat. No. from device and refer to Industrial Control Catalog). —<br />

Overload Relay Reset Operator for all NEMA Type enclosures<br />

Controller Frame Size & Type<br />

NR = Non-Reversing<br />

R = Reversing<br />

Catalog Number<br />

49MBRS<br />

Type 1 Type 1 Type 3/3R/4/12 Type 4X 304 S.S.<br />

Standard Size Large Size e Standard Size f Standard Size f<br />

Catalog Number Catalog Number Catalog Number Catalog Number<br />

S00 NR, S0 NR 49EC14EB110705R 49EC14GB140807R c 49EFN121006XRX 49EFW121006XRX<br />

S00 R, S0 R 49EC14GB140807R c 49EC14IB201208R d 49EFN121006XRX 49EFW121006XRX<br />

S2 NR, S2 R 49EC14IB201208R df — 49EFN141208XRX 49EFW141208XRX<br />

a The accessory in a NEMA type 1 enclosure requires a<br />

large size enclosure. All other enclosure types may be<br />

standard size.<br />

b Requires DIN rail kit or equivalent.<br />

c Enclosure 49EC14GB140807R requires mounting adaptor<br />

plate 49EFA070500XXA which is sold seperately.<br />

d Enclosure 49EC14IB201208R requires mounting adaptor<br />

plate 49EFA060800XXA which is sold seperately.<br />

e These large enclosures are required for certain<br />

accessories as indicated in the Field Modification pages.<br />

f These standard size enclosures include extra mounting<br />

space for accessories.<br />

17-188<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Enclosed IEC Controls<br />

3RE4 Outline Diagrams<br />

Revised on 05/31/19<br />

Technical information<br />

E<br />

A<br />

D<br />

B<br />

Figure 1 Figure 2<br />

C<br />

Soft Starter<br />

Control<br />

3RE4 Non-Combination Type Controllers<br />

Enclosure<br />

Outline Dimensions Mounting Conduit Size<br />

Type Contactor Rating Fig. A B C D E K1 K2 K3<br />

S00 NR, S0 NR 1 10.97 6.41 5.03 8.22 4.62 0.5 0.50-0.75 0.75–1<br />

1 (standard size)<br />

S00 R, S0 R 1 13.53 7.97 6.38 10.25 6.00 0.50-0.75 0.75-1 1-1.25<br />

S2 NR, S2 R 1 19.12 11.38 7.69 15.62 8.25 0.50-0.75 1-1.25 1.5-2<br />

1 (large size)<br />

S00 NR, S0 NR 1 13.53 7.97 6.38 10.25 6.00 0.50-0.75 0.75-1 1-1.25<br />

S00 R, S0 R 1 19.12 11.38 7.69 15.62 8.25 0.50-0.75 1-1.25 1.5-2<br />

3/3R/4/12 & 4X 304 SS<br />

S00 NR, S00 R, S0 NR, S0 R 2 12.00 10.00 6.00 11.30 7.44 — — —<br />

S2 NR, S2 R 2 14.00 12.00 8.00 13.30 9.44 — — —<br />

Sxx = Frame size; NR = Non-reversing; R = Reversing<br />

Mounting screw G is 0.25”.<br />

Dimensions are in inches.<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-189


Enclosed IEC Controls<br />

3RE4 Wiring Diagrams<br />

Revised on 05/31/19<br />

Technical information<br />

CONTROL<br />

PRODUCTS<br />

17<br />

Soft Starter<br />

Control<br />

17-190<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Enclosed IEC Controls<br />

3RE4 Wiring Diagrams<br />

Revised on 05/31/19<br />

Technical information<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-191


Enclosed IEC Controls<br />

3RE4 Wiring Diagrams<br />

Revised on 05/31/19<br />

Technical information<br />

CONTROL<br />

PRODUCTS<br />

17<br />

Soft Starter<br />

Control<br />

17-192<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Motor Starters, Soft Starters and Load Feeders<br />

Introduction<br />

Overview<br />

3RW30<br />

3RW40<br />

For operation in the control cabinet<br />

3RW soft starters for standard applications<br />

• Application areas<br />

- Fans<br />

- Building/construction machines<br />

- Escalators<br />

- Air conditioning systems<br />

- Assembly lines<br />

- Operating mechanisms<br />

3RW30 soft starters<br />

3RW40 soft starters<br />

3RW soft starters for high-feature applications<br />

• Application areas<br />

- Pumps<br />

- Compressors<br />

- Industrial refrigerating systems<br />

- Conveying systems<br />

- Machine tools<br />

3RW44 soft starters<br />

For enclosed applications<br />

Enclosures in NEMA 1, 3, 4, & 12 types<br />

UL/CSA listed<br />

3RW44<br />

- Pumps<br />

- Presses<br />

- Transport systems<br />

- Fans<br />

- Compressors and coolers<br />

• SIRIUS 3RW30 soft starters for soft starting and smooth ramp-down of threephase<br />

asynchronous motors<br />

• Performance range of up to 75 Hp (at 460 V)<br />

• SIRIUS 3RW40 soft starters with the integral functions<br />

- Solid-state motor overload and intrinsic device protection and<br />

- Adjustable current limiting<br />

for the soft starting and stopping of three-phase asynchronous motors<br />

• Performance range of up to 300 Hp (at 460 V)<br />

- Fans<br />

- Cooling systems<br />

- Water transport<br />

- Hydraulics<br />

- Mills<br />

• In addition to soft starting and soft ramp-down, the solid-state SIRIUS 3RW44<br />

soft starters provide numerous functions for higher-level requirements<br />

• Performance range<br />

- Up to 900 Hp (at 460 V) in inline circuit and<br />

- Up to 1600 Hp (at 460 V) in inside-delta circuit<br />

• Complete starter includes 3RW40 or 3RW44 and CPT<br />

• Performance Range of up to 600 Hp (at 460 V)<br />

• Combination options include circuit breaker or fusible disconnect<br />

• Application areas:<br />

- Compressors<br />

- Pumps<br />

- Stamping presses<br />

- Cooling towers<br />

- Molding and extruding<br />

- Chippers and debarkers<br />

- Lumber processing<br />

- Pulp & paper processing<br />

- Conveyors<br />

- Textiles<br />

- HVAC<br />

Class 73/74 Enclosed<br />

Order No. Page<br />

3RW30<br />

3RW40<br />

3RW44<br />

Class 73/74<br />

17-195<br />

17-199<br />

17-207<br />

17-274<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-193


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

General Data<br />

Overview<br />

The advantages of the SIRIUS soft starters at a glance:<br />

• Soft starting and smooth ramp-down 1)<br />

• Stepless starting<br />

• Reduction of current peaks<br />

• Avoidance of mains voltage fluctuations during starting<br />

• Reduced load on the power supply network<br />

• Reduction of the mechanical load in the operating mechanism<br />

• Considerable space savings and reduced wiring compared<br />

with conventional starters<br />

• Maintenance-free switching<br />

• Very easy handling<br />

• Fits perfectly in the SIRIUS modular system<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

SIRIUS 3RW30 SIRIUS 3RW40 SIRIUS 3RW44<br />

Standard applications Standard applications High-Feature applications<br />

Rated current up to 50 °C A 3 ... 98 11 ... 385 26 ... 1076<br />

Rated operational voltage V 200 ... 480<br />

200 ... 600<br />

200 ... 690<br />

Motor rating at 460 V<br />

• Inline circuit Hp 1.5 ... 75 7.5 ... 300 15 ... 900<br />

• Inside-delta circuit Hp -- -- 22 ... 1600<br />

Ambient temperature °C -25 ... +60<br />

-25 ... +60<br />

0 ... +60<br />

Soft starting/ramp-down 1)<br />

Voltage ramp<br />

Starting/stopping voltage % 40 ... 100 40 ... 100 20 ... 100<br />

Starting and ramp-down time 7)<br />

s 0 ... 20<br />

0 ... 20<br />

1 ... 360<br />

Torque control -- --<br />

Starting/stopping torque % --<br />

--<br />

20 ... 100<br />

Torque limit % -- -- 20 ... 200<br />

Ramp time s --<br />

--<br />

1 ... 360<br />

Integral bypass contact system<br />

Intrinsic device protection --<br />

Motor overload protection --<br />

Thermistor motor protection -- 2)<br />

Integrated remote RESET -- 3)<br />

Adjustable current limiting --<br />

Inside-delta circuit -- --<br />

Breakaway pulse --<br />

--<br />

Creep speed in both directions of rotation -- --<br />

Pump ramp-down --<br />

--<br />

4)<br />

DC braking -- -- 4) 5)<br />

Combined braking --<br />

--<br />

4) 5)<br />

Motor heating -- --<br />

Communication --<br />

--<br />

With PROFIBUS DP (optional)<br />

External display and operator module -- -- (optional)<br />

Operating measured value display --<br />

--<br />

Error logbook -- --<br />

Event list --<br />

--<br />

Slave pointer function -- --<br />

Trace function --<br />

--<br />

6)<br />

Programmable control inputs and outputs -- --<br />

Number of parameter sets 1<br />

1<br />

3<br />

Parameterization software (Soft Starter ES) -- --<br />

Power semiconductors (thyristors) 2 controlled phases 2 controlled phases<br />

3 controlled phases<br />

Screw terminals<br />

Spring-type terminals<br />

UL/CSA<br />

CE marking<br />

Soft starting under heavy starting conditions -- --<br />

4)<br />

Configuring support Win-Soft Starter, Electronic Application Selector, Technical Assistance Tel.: 1-800-333-7421<br />

Function is available; -- Function is not available.<br />

1) Only soft starting available for 3RW30.<br />

2) Optional up to size S3 (device variant).<br />

3) Available for 3RW40 2. to 3RW40 4.; optional for 3RW40 5. and 3RW40 7..<br />

4) Calculate soft starter and motor with size allowance where required.<br />

5) Not possible in inside-delta circuit.<br />

6) 7) Trace function with Soft Starter ES software.<br />

Actual motor start times are load dependent.<br />

You can find further information on the Internet at:<br />

www.usa.siemens.com/softstarters<br />

17-194<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW30 for standard applications<br />

Overview<br />

The SIRIUS 3RW30 soft starters reduce the motor voltage<br />

through variable phase control and increase it in ramp-like mode<br />

from a selectable starting voltage up to mains voltage. During<br />

starting, these devices limit the torque as well as the current and<br />

prevent the shocks which arise during direct starts or wye-delta<br />

starts. In this way, mechanical loads and mains voltage dips can<br />

be reliably reduced.<br />

Soft starting reduces the stress on the connected equipment<br />

and results in lower wear and therefore longer periods of troublefree<br />

production. The selectable start value means that the soft<br />

starters can be adjusted individually to the requirements of the<br />

application in question and unlike wye-delta starters are not<br />

restricted to two-stage starting with fixed voltage ratios. 1)<br />

The SIRIUS 3RW30 soft starters are characterized above all by<br />

their small space requirements. Integrated bypass contacts<br />

mean that minimal power loss is used at the power semiconductors<br />

(thyristors) after the motor has started up. This cuts down on<br />

heat losses, enabling a more compact design and making external<br />

bypass circuits superfluous.<br />

Various versions of the SIRIUS 3RW30 soft starters are available:<br />

• Standard version for fixed-speed three-phase motors, sizes<br />

S00, S0, S2 and S3, with integrated bypass contact system<br />

• Version for fixed-speed three-phase motors in a 22.5 mm<br />

enclosure without bypass<br />

Soft starters rated up to 75 Hp (at 460 V) for standard applications<br />

in three-phase networks are available. Extremely small<br />

sizes, low power losses and simple start-up are just three of the<br />

many advantages of this soft starter.<br />

Application<br />

The 3RW30 soft starters are suitable for soft starting of threephase<br />

asynchronous motors.<br />

Due to two-phase control, the current is kept at minimum values<br />

in all three phases throughout the entire starting time. Due<br />

to continuous voltage influencing, current and torque peaks,<br />

which are unavoidable in the case of wye-delta starters, for<br />

instance, do not occur.<br />

Application areas<br />

• Pumps<br />

• Heat pumps<br />

• Hydraulic pumps<br />

• Presses<br />

• Conveyors<br />

• Roller conveyor<br />

• Screw conveyors<br />

Soft Starter<br />

Control<br />

1) Actual motor start times are load dependent.<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-195


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW30 for standard applications<br />

Selection and ordering data<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

3RW30 18-1BB14 3RW30 28-1BB14 3RW30 38-1BB14 3RW30 47-1BB14 3RW30 03-2CB54<br />

Ambient temperature 40 °C Ambient temperature 50 °C Size Order No. List<br />

Rated Rated power of induction<br />

motors for rated<br />

operational<br />

current<br />

I<br />

operational voltage U e<br />

1)<br />

e<br />

Rated Rated power of induction<br />

operational<br />

cur-<br />

voltage U e<br />

motors for rated operational<br />

1)<br />

rent I e<br />

Price $<br />

per PU<br />

PS*<br />

Weight<br />

per PU<br />

approx.<br />

230 V 400 V 500 V 200 V 230 V 460 V 575 V<br />

A kW kW kW A hp hp hp hp<br />

Rated operational voltage U e 200 ... 480 V<br />

• With screw terminals<br />

3.6 0.75 1.5 -- 3 0.5 0.5 1.5 -- S00 3RW30 13-1BB@4 1 unit 0.580<br />

6.5 1.5 3 -- 4.8 1 1 3 -- S00 3RW30 14-1BB@4 1 unit 0.580<br />

9 2.2 4 -- 7.8 2 2 5 -- S00 3RW30 16-1BB@4 1 unit 0.580<br />

12.5 3 5.5 -- 11 3 3 7.5 -- S00 3RW30 17-1BB@4 1 unit 0.580<br />

17.6 4 7.5 -- 17 3 3 10 -- S00 3RW30 18-1BB@4 1 unit 0.580<br />

• With spring-type terminals<br />

3.6 0.75 1.5 -- 3 0.5 0.5 1.5 -- S00 3RW30 13-2BB@4 1 unit 0.580<br />

6.5 1.5 3 -- 4.8 1 1 3 -- S00 3RW30 14-2BB@4 1 unit 0.580<br />

9 2.2 4 -- 7.8 2 2 5 -- S00 3RW30 16-2BB@4 1 unit 0.580<br />

12.5 3 5.5 -- 11 3 3 7.5 -- S00 3RW30 17-2BB@4 1 unit 0.580<br />

17.6 4 7.5 -- 17 3 3 10 -- S00 3RW30 18-2BB@4 1 unit 0.580<br />

• With screw terminals<br />

25 5.5 11 -- 23 5 5 15 -- S0 3RW30 26-1BB@4 1 unit 0.690<br />

32 7.5 15 -- 29 7.5 7.5 20 -- S0 3RW30 27-1BB@4 1 unit 0.690<br />

38 11 18.5 -- 34 10 10 25 -- S0 3RW30 28-1BB@4 1 unit 0.690<br />

• With spring-type terminals<br />

25 5.5 11 -- 23 5 5 15 -- S0 3RW30 26-2BB@4 1 unit 0.690<br />

32 7.5 15 -- 29 7.5 7.5 20 -- S0 3RW30 27-2BB@4 1 unit 0.690<br />

38 11 18.5 -- 34 10 10 25 -- S0 3RW30 28-2BB@4 1 unit 0.690<br />

• With screw-type or spring-type terminals<br />

45 11 22 -- 42 10 15 30 -- S2 3RW30 36-@BB@4 1 unit 1.200<br />

63 18.5 30 -- 58 15 20 40 -- S2 3RW30 37-@BB@4 1 unit 1.200<br />

72 22 37 -- 62 20 20 40 -- S2 3RW30 38-@BB@4 1 unit 1.200<br />

• With screw-type or spring-type terminals<br />

80 22 45 -- 73 20 25 50 -- S3 3RW30 46-@BB@4 1 unit 1.710<br />

106 30 55 -- 98 30 30 75 -- S3 3RW30 47-@BB@4 1 unit 1.710<br />

Order No. supplement for connection types<br />

• With screw terminals 1<br />

• With spring-type terminals 2) 2<br />

Order No. supplement for rated control supply voltage U s<br />

• 24 V AC/DC 0<br />

• 110 ... 230 V 1<br />

Soft starters for easy starting conditions and high switching frequency,<br />

rated operational voltage U e 200 ... 400 V,<br />

rated control supply voltage U s 24 ... 230 V AC/DC<br />

3 0.55 1.1 -- 2.6 0.5 0.5 -- -- 22.5 mm<br />

• With screw terminals 3RW30 03-1CB54 1 unit 0.207<br />

• With spring-type terminals 3RW30 03-2CB54 1 unit 0.188<br />

1) Stand-alone installation.<br />

2) Power connection: screw terminals.<br />

Note:<br />

Selection of the soft starter depends on the rated motor current.<br />

The SIRIUS 3RW30 solid-state soft starters are designed for<br />

easy starting conditions. J Load < 10 x J Motor . In the event of<br />

deviating conditions or increased switching frequency, it may be<br />

necessary to choose a larger device.<br />

Siemens recommends the use of the selection and simulation<br />

program Win-Soft Starter. For information about rated currents<br />

for ambient temperatures > 40 °C, see technical specifications<br />

(see technical information on page 17-235).<br />

17-196<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW30 for standard applications<br />

Accessories<br />

For soft starters Motor starter protectors Order No. List<br />

Type Size Size<br />

Price $<br />

per PU<br />

PS*<br />

Weight<br />

per PU<br />

approx<br />

.<br />

kg<br />

Auxiliary terminals<br />

Auxiliary terminals, 3-pole<br />

3RW30 4. S3 3RT19 46-4F 1 unit 0.035<br />

Covers for soft starters<br />

Terminal covers for box terminals<br />

Additional touch protection to be fitted at the box terminals<br />

(2 units required per device)<br />

3RW30 3. S2 3RT19 36-4EA2 1 unit 0.020<br />

3RW30 4. S3 3RT19 46-4EA2 1 unit 0.025<br />

Terminal covers for cable lugs and busbar connections<br />

For complying with the phase clearances and as touch<br />

protection if box terminal is removed<br />

(2 units required per contactor)<br />

3RW30 4. S3 3RT19 46-4EA1 1 unit 0.040<br />

Link modules to motor starter protectors<br />

3RW30 13, S00 S0 3RA19 21-1A 10 units 0.028<br />

3RW30 14,<br />

3RW30 16,<br />

3RW30 17,<br />

3RW30 18<br />

3RW30 26 S0 S0 3RA19 21-1A 10 units 0.028<br />

3RW30 36 S2 S2 3RA19 31-1A 5 units 0.033<br />

3RW30 46,<br />

3RW30 47<br />

S3 S3 3RA19 41-1A 5 units 0.072<br />

Soft Starter<br />

Control<br />

Operating instructions 1)<br />

For soft starters<br />

3RW30 1.<br />

3RW30 2.<br />

3RW30 3.<br />

3RW30 4.<br />

S00<br />

S0<br />

S2<br />

S3<br />

1) The operating instructions are included in the scope of supply.<br />

Version<br />

Functionality<br />

Functions<br />

Covers and push-in lugs (only for 3RW30 03)<br />

Sealable covers For securing against<br />

unauthorized adjustment<br />

of setting knobs<br />

Push-in lugs<br />

3RP1 902<br />

For screw fixing<br />

3ZX10 12-0RW30-2DA1<br />

Order No.<br />

List<br />

Price $<br />

per PU<br />

Weight<br />

per PU<br />

approx.<br />

kg<br />

3RP1 902 5 units 0.004<br />

3RP1 903 10 units 0.002<br />

17 CONTROL<br />

PRODUCTS<br />

3RP1 903<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-197


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW30 for standard applications<br />

More information<br />

Application examples for normal starting (Class 10)<br />

Normal starting Class 10 (up to 20 s with 300 % I n motor ),<br />

The soft starter rating can be selected to be as high as the rating of the motor used.<br />

Application Conveyor belt Roller conveyor Compressor Small fan Pump Hydraulic pump<br />

Starting parameters<br />

• Voltage ramp and current<br />

limiting<br />

- Starting voltage % 70 60 50 40 40 40<br />

- Starting time s 10 10 20 20 10 10<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Note:<br />

These tables present sample set values and device sizes. They<br />

are intended only for the purposes of information and are not<br />

binding. The set values depend on the application in question<br />

and must be optimized during start-up. Actual start times are<br />

load dependent.<br />

The soft starter dimensions should be checked where necessary<br />

with the Win-Soft Starter software or with the help of Technical<br />

Assistance.<br />

Configuration<br />

The 3RW solid-state motor controllers are designed for easy<br />

starting conditions. In the event of deviating conditions or increased<br />

switching frequency, it may be necessary to choose a<br />

larger device. For accurate dimensioning, use the Win-Soft<br />

Starter selection and simulation program.<br />

If necessary, an overload relay for heavy starting must be selected<br />

where long starting times are involved. PTC sensors are<br />

recommended.<br />

In the motor feeder between the SIRIUS 3RW soft starter and the<br />

motor, no capacitive elements are permitted (e. g. no reactivepower<br />

compensation equipment). In addition, neither static systems<br />

for reactive-power compensation nor dynamic PFC (Power<br />

Factor Correction) must be operated in parallel during starting<br />

and ramp-down of the soft starter. This is important to prevent<br />

faults arising on the compensation equipment and/or the soft<br />

starter.<br />

All elements of the main circuit (such as fuses, controls and overload<br />

relays) should be dimensioned for direct starting, following<br />

the local short-circuit conditions. Fuses, controls and overload<br />

relays must be ordered separately. Please observe the maximum<br />

switching frequencies specified in the technical<br />

specifications.<br />

Note:<br />

When induction motors are switched on, voltage drops normally<br />

appear on starters of all types (direct starters, wye-delta starters,<br />

soft starters). The infeed transformer must always be dimensioned<br />

such that the voltage dip when starting the motor remains<br />

within the permissible tolerance. If the infeed transformer is dimensioned<br />

with only a small margin, it is best for the control voltage<br />

to be supplied from a separate circuit (independently of the<br />

main voltage) in order to avoid the potential switching off of the<br />

soft starter.<br />

Status graphs<br />

U<br />

U<br />

U<br />

N<br />

S<br />

ON 13/14<br />

t R on<br />

t R on<br />

Win-Soft Starter selection and simulation program<br />

With this software, you can simulate and select all Siemens soft<br />

starters, taking into account various parameters such as mains<br />

properties, motor and load data, and special application<br />

requirements.<br />

The software is a valuable tool, which makes complicated,<br />

lengthy manual calculations for determining the required soft<br />

starters superfluous.<br />

The Win-Soft Starter selection and simulation program can be<br />

downloaded from:<br />

http://www.siemens.de/sanftstarter > Software<br />

More information can be found on the Internet at:<br />

http://www.sea.siemens.com/softstarters<br />

t<br />

t<br />

NSB0_01941<br />

Power electronics schematic circuit diagram<br />

L1<br />

L2<br />

L3<br />

T1<br />

T2<br />

T3<br />

NSB0_01940<br />

A bypass contact system is already integrated in the 3RW30 soft<br />

starter and therefore does not have to be ordered separately.<br />

17-198<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW40 for standard applications<br />

Overview<br />

SIRIUS 3RW40 soft starters have all the same advantages as the<br />

3RW30 soft starters.<br />

The SIRIUS 3RW40 soft starters are characterized above all by<br />

their small space requirements. Integrated bypass contacts<br />

mean that minimal power is used at the power semiconductors<br />

(thyristors) after the motor has started up. This cuts down on<br />

heat losses, enabling a more compact design and making external<br />

bypass circuits superfluous.<br />

At the same time this soft starter comes with additional integrated<br />

functions such as adjustable current limiting, motor overload<br />

and intrinsic device protection, and optional thermistor motor<br />

protection on some models.<br />

Internal intrinsic device protection prevents the thermal overloading<br />

of the thyristors and the power section defects this can<br />

cause. As an option the thyristors can also be protected by<br />

semiconductor fuses from short-circuiting.<br />

Thanks to integrated status monitoring and fault monitoring, this<br />

compact soft starter offers many different diagnostics options.<br />

Up to four LEDs and relay outputs permit differentiated monitoring<br />

and diagnostics of the operating mechanism by indicating<br />

the operating state as well as for example mains or phase failure,<br />

missing load, non-permissible tripping time/class setting, thermal<br />

overloading or device faults.<br />

Soft starters rated up to 300 Hp (at 460 V) for standard applications<br />

in three-phase systems are available. Extremely small<br />

sizes, low power losses and simple start-up are just three of the<br />

many advantages of the SIRIUS 3RW40 soft starters.<br />

"Increased safety" type of protection EEx e according to<br />

ATEX directive 94/9/EC<br />

The 3RW40 soft starter sizes S0 to S12 are suitable for the starting<br />

of explosion-proof motors with "increased safety" type of protection<br />

EEx e.<br />

See "Appendix" –> "Standards and approvals" –> "Type overview<br />

of approved devices for potentially explosive areas (ATEX<br />

explosion protection)".<br />

Application<br />

The SIRIUS 3RW40 solid-state soft starters are suitable for soft<br />

starting and stopping of three-phase asynchronous motors.<br />

Due to two-phase control, the current is kept at minimum values<br />

in all three phases throughout the entire starting time and disturbing<br />

direct current components are eliminated in addition.<br />

This not only enables the two-phase starting of motors up to<br />

300 Hp (at 460 V) but also avoids the current and torque peaks<br />

which occur e. g. with wye-delta starters.<br />

Application areas<br />

• Pumps<br />

• Heat pumps<br />

• Hydraulic pumps<br />

• Presses<br />

• Conveyors<br />

• Roller conveyor<br />

• Screw conveyors<br />

• Escalators<br />

• Small fans<br />

• Centrifugal blowers<br />

• Bow thrusters<br />

• Stirrers<br />

• Extruders<br />

• Lathes<br />

• Milling machines<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-199


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW40 for standard applications<br />

Selection and ordering data<br />

3RW40 28-1BB14<br />

3RW40 38-1BB14<br />

3RW40 47-1BB14<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Ambient temperature 50 °C Size Order No. List<br />

Rated<br />

operational<br />

current I e<br />

1)<br />

Rated power of induction motors<br />

for rated operational voltage U e<br />

Price $<br />

per PU<br />

PS*<br />

Weight per<br />

PU approx.<br />

200 V 230 V 460 V 575 V<br />

A hp hp hp hp kg<br />

Rated operational voltage U e 200 ... 480 V<br />

• With screw terminals<br />

11 3 3 7.5 -- S0 3RW40 24-1BB@4 1 unit 0.770<br />

23 5 5 15 -- S0 3RW40 26-1BB@4 1 unit 0.770<br />

29 7.5 7.5 20 -- S0 3RW40 27-1BB@4 1 unit 0.770<br />

34 10 10 25 -- S0 3RW40 28-1BB@4 1 unit 0.770<br />

• With spring-type terminals<br />

11 3 3 7.5 -- S0 3RW40 24-2BB@4 1 unit 0.770<br />

23 5 5 15 -- S0 3RW40 26-2BB@4 1 unit 0.770<br />

29 7.5 7.5 20 -- S0 3RW40 27-2BB@4 1 unit 0.770<br />

34 10 10 25 -- S0 3RW40 28-2BB@4 1 unit 0.770<br />

• With screw or spring-type terminals<br />

42 10 15 30 -- S2 3RW40 36-@BB@4 1 unit 1.350<br />

58 15 20 40 -- S2 3RW40 37-@BB@4 1 unit 1.350<br />

62 20 20 40 -- S2 3RW40 38-@BB@4 1 unit 1.350<br />

• With screw or spring-type terminals<br />

73 20 25 50 -- S3 3RW40 46-@BB@4 1 unit 1.900<br />

98 30 30 75 -- S3 3RW40 47-@BB@4 1 unit 1.900<br />

Rated operational voltage U e 400 ... 600 V<br />

• With screw terminals<br />

11 -- -- 7.5 10 S0 3RW40 24-1BB@5 1 unit 0.770<br />

23 -- -- 15 20 S0 3RW40 26-1BB@5 1 unit 0.770<br />

29 -- -- 20 25 S0 3RW40 27-1BB@5 1 unit 0.770<br />

34 -- -- 25 30 S0 3RW40 28-1BB@5 1 unit 0.770<br />

• With spring-type terminals<br />

11 -- -- 7.5 10 S0 3RW40 24-2BB@5 1 unit 0.770<br />

23 -- -- 15 20 S0 3RW40 26-2BB@5 1 unit 0.770<br />

29 -- -- 20 25 S0 3RW40 27-2BB@5 1 unit 0.770<br />

34 -- -- 25 30 S0 3RW40 28-2BB@5 1 unit 0.770<br />

• With screw or spring-type terminals<br />

42 -- -- 30 40 S2 3RW40 36-@BB@5 1 unit 1.350<br />

58 -- -- 40 50 S2 3RW40 37-@BB@5 1 unit 1.350<br />

62 -- -- 40 60 S2 3RW40 38-@BB@5 1 unit 1.350<br />

• With screw or spring-type terminals<br />

73 -- -- 50 60 S3 3RW40 46-@BB@5 1 unit 1.900<br />

98 -- -- 75 75 S3 3RW40 47-@BB@5 1 unit 1.900<br />

Order No. supplement for connection types<br />

• With screw terminals 1<br />

• With spring-type terminals 2) 2<br />

Order No. supplement for rated control supply voltage U s<br />

• 24 V AC/DC 0<br />

• 110 ... 230 V AC/DC 1<br />

1) Stand-alone installation without auxiliary fan.<br />

Power connection: screw terminals.<br />

Note:<br />

Selection of the soft starter depends on the rated motor current.<br />

The SIRIUS 3RW40 solid-state soft starters are designed for<br />

easy starting conditions. J Load < 10 x J Motor . In the event of deviating<br />

conditions or increased switching frequency, it may be<br />

necessary to choose a larger device. Siemens recommends the<br />

use of the selection and simulation program Win-Soft Starter. For<br />

information about rated currents for ambient temperatures other<br />

than 50°C, see technical information on page 17-247<br />

17-200<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW40 for standard applications<br />

3RW40 28-1TB04<br />

3RW40 38-1TB04<br />

3RW40 47-1TB04<br />

Ambient temperature 50 °C Size Order No. List<br />

PS*<br />

Weight per<br />

Rated Rated power of induction motors<br />

Price $<br />

PU approx.<br />

operational for rated operational voltage U<br />

per PU<br />

e<br />

1) current I e<br />

200 V 230 V 460 V 575 V<br />

A hp hp hp hp kg<br />

Rated operational voltage U e 200 ... 480 V,<br />

with thermistor motor protection,<br />

rated control supply voltage U s 24 V AC/DC<br />

• With screw terminals<br />

11 3 3 7.5 -- S0 3RW40 24-1TB04 1 unit 0.770<br />

23 5 5 15 -- S0 3RW40 26-1TB04 1 unit 0.770<br />

29 7.5 7.5 20 -- S0 3RW40 27-1TB04 1 unit 0.770<br />

34 10 10 25 -- S0 3RW40 28-1TB04 1 unit 0.770<br />

• With spring-type terminals<br />

11 3 3 7.5 -- S0 3RW40 24-2TB04 1 unit 0.770<br />

23 5 5 15 -- S0 3RW40 26-2TB04 1 unit 0.770<br />

29 7.5 7.5 20 -- S0 3RW40 27-2TB04 1 unit 0.770<br />

34 10 10 25 -- S0 3RW40 28-2TB04 1 unit 0.770<br />

• With screw or spring-type terminals<br />

42 10 15 30 -- S2 3RW40 36-@TB04 1 unit 1.350<br />

58 15 20 40 -- S2 3RW40 37-@TB04 1 unit 1.350<br />

62 20 20 40 -- S2 3RW40 38-@TB04 1 unit 1.350<br />

• With screw or spring-type terminals<br />

73 20 25 50 -- S3 3RW40 46-@TB04 1 unit 1.900<br />

98 30 30 75 -- S3 3RW40 47-@TB04 1 unit 1.900<br />

Rated operational voltage U e 400 ... 600 V,<br />

with thermistor motor protection,<br />

rated control supply voltage U s 24 V AC/DC<br />

• With screw terminals<br />

11 -- -- 7.5 10 S0 3RW40 24-1TB05 1 unit 0.770<br />

23 -- -- 15 20 S0 3RW40 26-1TB05 1 unit 0.770<br />

29 -- -- 20 25 S0 3RW40 27-1TB05 1 unit 0.770<br />

34 -- -- 25 30 S0 3RW40 28-1TB05 1 unit 0.770<br />

• With spring-type terminals<br />

11 -- -- 7.5 10 S0 3RW40 24-2TB05 1 unit 0.770<br />

23 -- -- 15 20 S0 3RW40 26-2TB05 1 unit 0.770<br />

29 -- -- 20 25 S0 3RW40 27-2TB05 1 unit 0.770<br />

34 -- -- 25 30 S0 3RW40 28-2TB05 1 unit 0.770<br />

• With screw or spring-type terminals<br />

42 -- -- 30 40 S2 3RW40 36-@TB05 1 unit 1.350<br />

58 -- -- 40 50 S2 3RW40 37-@TB05 1 unit 1.350<br />

62 -- -- 40 60 S2 3RW40 38-@TB05 1 unit 1.350<br />

• With screw or spring-type terminals<br />

73 -- -- 50 60 S3 3RW40 46-@TB05 1 unit 1.900<br />

98 -- -- 75 75 S3 3RW40 47-@TB05 1 unit 1.900<br />

Order No. supplement for connection types<br />

• With screw terminals 1<br />

• With spring-type terminals 2) 2<br />

1) Stand-alone installation without auxiliary fan.<br />

Power connection: screw terminals.<br />

Note:<br />

Selection of the soft starter depends on the rated motor current.<br />

The SIRIUS 3RW40 solid-state soft starters are designed for<br />

easy starting conditions. J Load < 10 x J Motor . In the event of deviating<br />

conditions or increased switching frequency, it may be<br />

necessary to choose a larger device. Siemens recommends the<br />

use of the selection and simulation program Win-Soft Starter. For<br />

information about rated currents for ambient temperatures<br />

> 40° C, see technical information on page 17-247<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-201


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW40 for standard applications<br />

3RW40 56-6BB44<br />

3RW40 76-6BB44<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Ambient temperature 50 °C Size Order No. List<br />

Rated<br />

operational<br />

current I e<br />

1)<br />

Rated power of induction motors<br />

for rated operational voltage U e<br />

• 115 V AC 3<br />

• 230 V AC 4<br />

1) Stand-alone installation.<br />

2) Power connection: busbar connection.<br />

3) Control by way of the internal 24 V DC supply and direct control by means<br />

of PLC possible.<br />

Note:<br />

Selection of the soft starter depends on the rated motor current.<br />

The SIRIUS 3RW40 solid-state soft starters are designed for<br />

easy starting conditions. J Load < 10 x J Motor . In the event of deviating<br />

conditions or increased switching frequency, it may be<br />

necessary to choose a larger device. Siemens recommends the<br />

use of the selection and simulation program Win-Soft Starter. For<br />

information about rated currents for ambient temperatures<br />

> 40° C, see technical information on page 17-247<br />

Price $<br />

per PU<br />

PS*<br />

Weight per<br />

PU approx.<br />

200 V 230 V 460 V 575 V<br />

A hp hp hp hp kg<br />

Rated operational voltage U e 200 ... 460 V<br />

• With screw or spring-type terminals<br />

117 30 40 75 -- S6 3RW40 55-@BB@4 1 unit 4.900<br />

145 40 50 100 -- 3RW40 56-@BB@4 1 unit 6.900<br />

• With screw or spring-type terminals<br />

205 60 75 150 -- S12 3RW40 73-@BB@4 1 unit 8.900<br />

248 75 100 200 -- 3RW40 74-@BB@4 1 unit 8.900<br />

315 100 125 250 -- 3RW40 75-@BB@4 1 unit 8.900<br />

385 125 150 300 -- 3RW40 76-@BB@4 1 unit 8.900<br />

Rated operational voltage U e 400 ... 600 V<br />

• With screw or spring-type terminals<br />

117 -- -- 75 100 S6 3RW40 55-@BB@5 1 unit 4.900<br />

145 -- -- 100 150 3RW40 56-@BB@5 1 unit 6.900<br />

• With screw or spring-type terminals<br />

205 -- -- 150 200 S12 3RW40 73-@BB@5 1 unit 8.900<br />

248 -- -- 200 250 3RW40 74-@BB@5 1 unit 8.900<br />

315 -- -- 250 300 3RW40 75-@BB@5 1 unit 8.900<br />

385 -- -- 300 400 3RW40 76-@BB@5 1 unit 8.900<br />

Order No. supplement for connection types 2)<br />

• With screw terminals 6<br />

• With spring-type terminals 2<br />

3)<br />

Order No. supplement for the rated control supply voltage U s<br />

17-202<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Modules for RESET 1) Modules for remote RESET, electrical<br />

For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW40 for standard applications<br />

Accessories<br />

For soft starters Version Order No. List<br />

Type Size<br />

Price $<br />

per PU<br />

PS*<br />

Weight<br />

per PU<br />

approx.<br />

kg<br />

Box terminal blocks for soft starters<br />

For round and flat wires<br />

3RW40 5. S6 • Up to 70 mm 2 3RT19 55-4G 1 unit 0.230<br />

• Up to 120 mm 2 3RT19 56-4G 1 unit 0.260<br />

3RW40 7. S12 • Up to 240 mm 2 3RT19 66-4G 1 unit 0.676<br />

Auxiliary terminals<br />

Auxiliary terminals, 3-pole<br />

3RW40 4. S3 3RT19 46-4F 1 unit 0.035<br />

Covers for soft starters<br />

Terminal covers for box terminals<br />

Additional touch protection to be fitted at the box terminals<br />

(2 units required per device)<br />

3RW40 3. S2 3RT19 36-4EA2 1 unit 0.020<br />

3RW40 4. S3 3RT19 46-4EA2 1 unit 0.025<br />

3RW40 5. S6 3RT19 56-4EA2 1 unit 0.030<br />

3RW40 7. S12 3RT19 66-4EA2 1 unit 0.040<br />

Terminal covers for cable lugs and busbar connections<br />

3RW40 4. S3 For complying with the phase clearances<br />

3RT19 46-4EA1 1 unit 0.040<br />

and as touch protection if box<br />

3RW40 5. S6 3RT19 56-4EA1 1 unit 0.070<br />

3RW40 7. S12<br />

terminal is removed<br />

3RT19 66-4EA1 1 unit 0.130<br />

(2 units required per contactor)<br />

Soft Starter<br />

Control<br />

Sealing covers<br />

3RW40 2. to<br />

3RW40 4.<br />

3RW40 5. and<br />

3RW40 7.<br />

S0,<br />

S2,<br />

S3<br />

S6,<br />

S12<br />

3RW49 00-0PB10 1 unit 0.005<br />

3RW49 00-0PB00 1 unit 0.010<br />

Operating range 0.85 ... 1.1 x U s ,<br />

power consumption 80 VA AC, 70 W DC,<br />

ON period 0.2 s ... 4 s,<br />

switching frequency 60/h<br />

3RW40 5. and<br />

3RW40 7.<br />

S6,<br />

S12<br />

• 24 ... 30 V AC/DC 3RU19 00-2AB71 1 unit 0.066<br />

• 110 ... 127 V AC/DC 3RU19 00-2AF71 1 unit 0.067<br />

• 220 ... 250 V AC/DC 3RU19 00-2AM71 1 unit 0.066<br />

Mechanical RESET comprising<br />

3RW40 5. and S6, • Resetting plungers, holders and 3RU19 00-1A 1 unit 0.038<br />

3RW40 7. S12 formers<br />

• Suitable pushbutton IP65, Ø 22 mm, 3SB30 00-0EA11 1 unit 0.020<br />

12 mm stroke<br />

• Extension plunger 3SX13 35 1 unit 0.004<br />

17 CONTROL<br />

PRODUCTS<br />

Cable releases with holder for RESET<br />

For Ø 6.5 mm holes in the control panel;<br />

max. control panel thickness 8 mm<br />

3RW40 5. and<br />

3RW40 7.<br />

S6,<br />

S12<br />

• Length 400 mm 3RU19 00-1B 1 unit 0.063<br />

• Length 600 mm 3RU19 00-1C 1 unit 0.073<br />

1) Remote RESET already integrated in the<br />

3RW40 2. to 3RW40 4. soft starters.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-203


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW40 for standard applications<br />

For soft starters<br />

Type Size<br />

Motor starter protectors<br />

Size<br />

Order No.<br />

List<br />

Price $<br />

per PU<br />

PS*<br />

Weight<br />

per PU<br />

approx.<br />

kg<br />

Link modules to motor starter protectors<br />

3RW40 24, S0 S0 3RA19 21-1A 10 units 0.028<br />

3RW40 26<br />

3RW40 36 S2 S2 3RA19 31-1A 5 units 0.033<br />

3RW40 46,<br />

3RW40 47<br />

S3 S3 3RA19 41-1A 5 units 0.072<br />

Soft Starter<br />

Control<br />

Fans (to increase switching frequency and for device mounting in<br />

positions different from the normal position)<br />

3RW40 2. S0 3RW49 28-8VB00 1 unit 0.010<br />

Operating instructions 1)<br />

3RW40 3.,<br />

3RW40 4.<br />

For soft starters<br />

3RW40 2.<br />

3RW40 3.<br />

3RW40 4.<br />

3RW40 5.<br />

3RW40 7.<br />

S2,<br />

S3<br />

S0<br />

S2<br />

S3<br />

S6<br />

S12<br />

1) The operating instructions are included in the scope of supply.<br />

They are also available on the Internet at:<br />

www.usa.siemens.com/softstarters<br />

3RW49 47-8VB00 1 unit 0.020<br />

3ZX10 12-0RW40-1AA1<br />

3ZX10 12-0RW40-2DA1<br />

Spare parts<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Fans<br />

For soft starters Version Order No. List<br />

Type Size Rated control supply<br />

voltage U s<br />

Price $<br />

per PU<br />

PS*<br />

Weight<br />

per PU<br />

approx.<br />

Fans<br />

3RW40 5.-.BB3. S6 115 V AC 3RW49 36-8VX30 1 unit 0.300<br />

3RW40 5.-.BB4. S6 230 V AC 3RW49 36-8VX40 1 unit 0.300<br />

3RW40 7.-.BB3. S12 115 V AC 3RW49 47-8VX30 1 unit 0.500<br />

3RW40 7.-.BB4. S12 230 V AC 3RW49 47-8VX40 1 unit 0.500<br />

kg<br />

17-204<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW40 for standard applications<br />

More information<br />

Application examples for normal starting (Class 10)<br />

Normal starting Class 10 (up to 20 s with 350 % I n motor ),<br />

The soft starter rating can be selected to be as high as the rating of the motor used.<br />

Application Conveyor belt Roller conveyor Small fan Pump Hydraulic pump<br />

Starting parameters<br />

• Voltage ramp and current<br />

limiting<br />

- Starting voltage % 70 60 40 40 40<br />

- Starting time s 10 10 10 10 10<br />

- Current limit value 5 x I M 5 x I M 4 x I M 4 x I M 4 x I M<br />

Ramp-down time s 5 5 0 10 0<br />

Application examples for heavy starting (Class 20)<br />

Heavy starting Class 20 (up to 40 s with 350 % I n motor ),<br />

The soft starter has to be selected at least one rating class higher than the motor used.<br />

Application Stirrer Centrifuge<br />

Starting parameters<br />

• Voltage ramp and current<br />

limiting<br />

- Starting voltage % 40 40<br />

- Starting time s 20 20<br />

- Current limit value 4 x I M 4 x I M<br />

Ramp-down time 0 0<br />

Soft Starter<br />

Control<br />

Note:<br />

These tables present sample set values and device sizes. They<br />

are intended only for the purposes of information and are not<br />

binding. The set values depend on the application in question<br />

and must be optimized during start-up. Actual start times are<br />

load dependent.<br />

The soft starter dimensions should be checked where necessary<br />

with the Win-Soft Starter software or with the help of Technical<br />

Assistance.<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-205


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW40 for standard applications<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Configuration<br />

The 3RW solid-state soft starters are designed for easy starting<br />

conditions. In the event of severe conditions or increased<br />

switching frequency, it may be necessary to choose a larger device.<br />

For accurate dimensioning, use the Win-Soft Starter selection<br />

and simulation program.<br />

Where long starting times are involved, the integrated solid-state<br />

overload relay for heavy starting should not be disconnected.<br />

PTC sensors are recommended. This also applies for the smooth<br />

ramp-down because during the ramp-down time an additional<br />

current loading applies in contrast to free ramp-down.<br />

In the case of high switching frequencies in S4 mode, Siemens<br />

recommends the use of PTC sensors. For corresponding device<br />

versions with integrated thermistor motor protection or separate<br />

thermistor evaluation devices see Industrial Controls catalog<br />

Chapter 11 “Function Relays, Interfaces and Converters“.<br />

In the motor feeder between the SIRIUS 3RW soft starter and the<br />

motor, no capacitive elements are permitted (e. g. no reactivepower<br />

compensation equipment, PFC capacitors). In addition,<br />

neither static systems for reactive-power compensation nor dynamic<br />

PFC (Power Factor Correction) must be operated in parallel<br />

during starting and ramp-down of the soft starter. This is important<br />

to prevent faults arising on the compensation equipment<br />

and/or the soft starter.<br />

All elements of the main circuit (such as fuses and controls)<br />

should be dimensioned for direct starting, following the local<br />

short-circuit conditions. Fuses, controls and overload relays<br />

must be ordered separately. Please observe the maximum<br />

switching frequencies specified in the technical specifications.<br />

Note:<br />

When induction motors are switched on, voltage drops normally<br />

appear on starters of all types (direct starters, wye-delta starters,<br />

soft starters). The infeed transformer must always be dimensioned<br />

such that the voltage dip when starting the motor remains<br />

within the permissible tolerance. If the infeed transformer is dimensioned<br />

with only a small margin, it is best for the control voltage<br />

to be supplied from a separate circuit (independently of the<br />

main voltage) in order to avoid the potential switching off of the<br />

soft starter.<br />

Power electronics schematic circuit diagram<br />

L1<br />

L2<br />

L3<br />

Status graphs 1)<br />

Win-Soft Starter selection and simulation program<br />

With this software, you can simulate and select all Siemens soft<br />

starters, taking into account various parameters such as mains<br />

properties, motor and load data, and special application<br />

requirements.<br />

The software is a valuable tool, which makes complicated,<br />

lengthy manual calculations for determining the required soft<br />

starters superfluous.<br />

The Win-Soft Starter selection and simulation program can be<br />

downloaded from:<br />

www.usa.siemens.com/softstarters > Software<br />

More information can be found on the Internet at:<br />

www.usa.siemens.com/softstarters<br />

T1 T2 T3<br />

A bypass contact system and solid-state overload relay are already<br />

integrated in the 3RW40 soft starter and therefore do not<br />

have to be ordered separately.<br />

NSB0_001485a<br />

1) U n = Full Voltage<br />

2) U s = Starting (Initial) Voltage<br />

3) t R = Time Running<br />

4) I e = Rated operational current<br />

17-206<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

Overview<br />

In addition to soft starting and soft ramp-down, the solid-state<br />

SIRIUS 3RW44 soft starters provide numerous functions for<br />

higher-level requirements. They cover a performance range up<br />

to 900 Hp (at 460 V) in the inline circuit and up to 1600Hp (at<br />

460 V) in the inside-delta circuit.<br />

The SIRIUS 3RW44 soft starters are characterized by a compact<br />

design for space-saving and clearly arranged control cabinet<br />

layouts. For optimized motor starting and stopping the innovative<br />

SIRIUS 3RW44 soft starters are an attractive alternative with<br />

considerable savings potential compared to applications with a<br />

frequency converter. The new torque control and adjustable current<br />

limiting enable the High-Feature soft starters to be used in<br />

nearly every conceivable task. They guarantee the reliable<br />

avoidance of sudden torque applications and current peaks during<br />

motor starting and stopping. This creates savings potential<br />

when calculating the size of the switchgear and when servicing<br />

the machinery installed. Whether it’s for inline circuits or insidedelta<br />

circuits – the SIRIUS 3RW44 soft starter offers savings especially<br />

in terms of size and equipment costs.<br />

The bypass contacts already integrated in the soft starter bypass<br />

the thyristors after a motor ramp-up is detected. This results<br />

in a further reduction in the heat loss occuring during operation<br />

of the soft starter.<br />

Combinations of various starting, operating and ramp-down<br />

possibilities ensure an optimum adaptation to the applicationspecific<br />

requirements. Operation and commissioning can be<br />

performed with the menu-controlled keypad and a menuprompted,<br />

multi-line graphical display with background lighting.<br />

The optimized motor ramp-up and ramp-down can be effected<br />

quickly, easily and reliably by means of just a few settings with a<br />

previously selected language. Four-key operation and plain-text<br />

displays for each menu point guarantee full clarity at every moment<br />

of the parameterization and operation.<br />

Applicable standards<br />

• IEC 60947-4-2<br />

• UL/CSA<br />

Soft Starter ES parameterization software<br />

Soft Starter ES software is used for the parameterization, monitoring<br />

and service diagnostics of SIRIUS 3RW44 High Feature<br />

soft starters.<br />

Application<br />

The SIRIUS 3RW44 solid-state soft starters are suitable for the<br />

torque-controlled soft starting and smooth ramp-down as well as<br />

braking of three-phase asynchronous motors.<br />

Application areas, e. g.<br />

• Pumps<br />

• Fans<br />

• Compressors<br />

• Water transport<br />

• Conveying systems and lifts<br />

• Hydraulics<br />

• Machine tools<br />

• Mills<br />

• Saws<br />

• Crushers<br />

• Mixers<br />

• Centrifuges<br />

• Industrial cooling and refrigerating systems<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-207


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

Selection and ordering data<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

3RW44 27-1BC44 3RW44 36-6BC44 3RW44 47-6BC44 3RW44 58-6BC44 3RW44 66-6BC44<br />

Ambient temperature 50 °C Order No. List<br />

Rated<br />

operational<br />

current I e<br />

Rated power of induction motors<br />

for rated operational voltage U e<br />

1) Control by way of the internal 24 V DC supply and direct control by means<br />

of PLC possible.<br />

2) For inside delta selection, see page 17-267.<br />

Note:<br />

Soft starter selection depends on the rated motor current.<br />

The 3RW44 solid-state soft starters are designed for normal<br />

starting (Class 10). (Inertia load of the overall operating mechanism<br />

J Load 40 °C and switching<br />

frequency.<br />

Price $<br />

per PU<br />

PS*<br />

Weight per<br />

PU approx.<br />

200 V 230 V 460 V 575 V<br />

A hp hp hp hp kg<br />

Inline circuits 2) , rated operational voltage 200 ... 460 V<br />

26 7.5 7.5 15 -- 3RW44 22-@BC@4 1 unit 6.500<br />

32 10 10 20 -- 3RW44 23-@BC@4 1 unit 6.500<br />

42 10 15 25 -- 3RW44 24-@BC@4 1 unit 6.500<br />

51 15 15 30 -- 3RW44 25-@BC@4 1 unit 6.500<br />

68 20 20 50 -- 3RW44 26-@BC@4 1 unit 6.500<br />

82 25 25 60 -- 3RW44 27-@BC@4 1 unit 6.500<br />

Order No. supplement for connection types<br />

• With spring-type terminals 3<br />

• With screw terminals 1<br />

100 30 30 75 -- 3RW44 34-@BC@4 1 unit 7.900<br />

117 30 40 75 -- 3RW44 35-@BC@4 1 unit 7.900<br />

145 40 50 100 -- 3RW44 36-@BC@4 1 unit 7.900<br />

180 50 60 125 -- 3RW44 43-@BC@4 1 unit 11.500<br />

215 60 75 150 -- 3RW44 44-@BC@4 1 unit 11.500<br />

280 75 100 200 -- 3RW44 45-@BC@4 1 unit 11.500<br />

315 100 125 250 -- 3RW44 46-@BC@4 1 unit 11.500<br />

385 125 150 300 -- 3RW44 47-@BC@4 1 unit 11.500<br />

494 150 200 400 -- 3RW44 53-@BC@4 1 unit 50.000<br />

551 150 200 450 -- 3RW44 54-@BC@4 1 unit 50.000<br />

615 200 250 500 -- 3RW44 55-@BC@4 1 unit 50.000<br />

693 200 250 550 -- 3RW44 56-@BC@4 1 unit 50.000<br />

780 250 300 600 -- 3RW44 57-@BC@4 1 unit 50.000<br />

850 300 350 700 -- 3RW44 58-@BC@4 1 unit 50.000<br />

970 350 400 800 -- 3RW44 65-@BC@4 1 unit 78.000<br />

1076 350 400 900 -- 3RW44 66-@BC@4 1 unit 78.000<br />

Order No. supplement for connection types<br />

• With spring-type terminals 2<br />

• With screw terminals 6<br />

1)<br />

Order No. supplement for the rated control supply voltage U s<br />

• 115 V AC 3<br />

• 230 V AC 4<br />

17-208<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

Ambient temperature 50 °C Order No. List<br />

Rated<br />

operational<br />

current I e<br />

Rated power of induction motors<br />

for rated operational voltage U e<br />

Price $<br />

per PU<br />

970 -- -- 800 1000 3RW44 65-@BC@5 1 unit 78.000<br />

1076 -- -- 900 1100 3RW44 66-@BC@5 1 unit 78.000<br />

Order No. supplement for connection types<br />

• With spring-type terminals 2<br />

• With screw terminals 6<br />

1)<br />

Order No. supplement for the rated control supply voltage U s<br />

• 115 V AC 3<br />

• 230 V AC 4<br />

1) Control by way of the internal 24 V DC supply and direct control by means<br />

of PLC possible.<br />

2)<br />

For inside delta selection, see page 17-267.<br />

Note:<br />

Soft starter selection depends on the rated motor current.<br />

The 3RW44 solid-state soft starters are designed for normal<br />

starting (Class 10). (Inertia load of the overall operating mechanism<br />

J Load 40 °C and switching<br />

frequency.<br />

PS*<br />

Weight per<br />

PU approx.<br />

200 V 230 V 460 V 575 V<br />

A hp hp hp hp kg<br />

Inline circuits 2) , rated operational voltage 400 ... 600 V<br />

26 -- -- 15 20 3RW44 22-@BC@5 1 unit 6.500<br />

32 -- -- 20 25 3RW44 23-@BC@5 1 unit 6.500<br />

42 -- -- 25 30 3RW44 24-@BC@5 1 unit 6.500<br />

51 -- -- 30 40 3RW44 25-@BC@5 1 unit 6.500<br />

68 -- -- 50 50 3RW44 26-@BC@5 1 unit 6.500<br />

82 -- -- 60 75 3RW44 27-@BC@5 1 unit 6.500<br />

Order No. supplement for connection types<br />

• With spring-type terminals 3<br />

• With screw terminals 1<br />

100 -- -- 75 75 3RW44 34-@BC@5 1 unit 7.900<br />

117 -- -- 75 100 3RW44 35-@BC@5 1 unit 7.900<br />

145 -- -- 100 125 3RW44 36-@BC@5 1 unit 7.900<br />

180 -- -- 125 150 3RW44 43-@BC@5 1 unit 11.500<br />

215 -- -- 150 200 3RW44 44-@BC@5 1 unit 11.500<br />

280 -- -- 200 250 3RW44 45-@BC@5 1 unit 11.500<br />

315 -- -- 250 300 3RW44 46-@BC@5 1 unit 11.500<br />

385 -- -- 300 400 3RW44 47-@BC@5 1 unit 11.500<br />

494 -- -- 400 500 3RW44 53-@BC@5 1 unit 50.000<br />

551 -- -- 450 550 3RW44 54-@BC@5 1 unit 50.000<br />

615 -- -- 500 600 3RW44 55-@BC@5 1 unit 50.000<br />

693 -- -- 550 700 3RW44 56-@BC@5 1 unit 50.000<br />

780 -- -- 600 800 3RW44 57-@BC@5 1 unit 50.000<br />

850 -- -- 700 850 3RW44 58-@BC@5 1 unit 50.000<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-209


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Ambient temperature 50 °C Order No. List<br />

Rated<br />

operational<br />

current I e<br />

Rated power of induction motors<br />

for rated operational voltage U e<br />

1) Control by way of the internal 24 V DC supply and direct control by means<br />

of PLC possible.<br />

Note:<br />

Soft starter selection depends on the rated motor current.<br />

The 3RW44 solid-state soft starters are designed for normal<br />

starting (Class 10). (Inertia load of the overall operating mechanism<br />

J Load 40 °C and switching<br />

frequency.<br />

Price $<br />

per PU<br />

PS*<br />

Weight per<br />

PU approx.<br />

200 V 230 V 460 V 575 V<br />

A hp hp hp hp kg<br />

Inline circuits, rated operational voltage 400 ... 690 V<br />

26 -- -- 15 20 3RW44 22-@BC@6 1 unit 6.500<br />

32 -- -- 20 25 3RW44 23-@BC@6 1 unit 6.500<br />

42 -- -- 25 30 3RW44 24-@BC@6 1 unit 6.500<br />

51 -- -- 30 40 3RW44 25-@BC@6 1 unit 6.500<br />

68 -- -- 50 50 3RW44 26-@BC@6 1 unit 6.500<br />

82 -- -- 60 75 3RW44 27-@BC@6 1 unit 6.500<br />

Order No. supplement for connection types<br />

• With spring-type terminals 3<br />

• With screw terminals 1<br />

100 -- -- 75 75 3RW44 34-@BC@6 1 unit 7.900<br />

117 -- -- 75 100 3RW44 35-@BC@6 1 unit 7.900<br />

145 -- -- 100 125 3RW44 36-@BC@6 1 unit 7.900<br />

180 -- -- 125 150 3RW44 43-@BC@6 1 unit 11.500<br />

215 -- -- 150 200 3RW44 44-@BC@6 1 unit 11.500<br />

280 -- -- 200 250 3RW44 45-@BC@6 1 unit 11.500<br />

315 -- -- 250 300 3RW44 46-@BC@6 1 unit 11.500<br />

385 -- -- 300 400 3RW44 47-@BC@6 1 unit 11.500<br />

494 -- -- 400 500 3RW44 53-@BC@6 1 unit 50.000<br />

551 -- -- 450 550 3RW44 54-@BC@6 1 unit 50.000<br />

615 -- -- 500 600 3RW44 55-@BC@6 1 unit 50.000<br />

693 -- -- 550 700 3RW44 56-@BC@6 1 unit 50.000<br />

780 -- -- 600 800 3RW44 57-@BC@6 1 unit 50.000<br />

850 -- -- 700 850 3RW44 58-@BC@6 1 unit 50.000<br />

970 -- -- 800 1000 3RW44 65-@BC@6 1 unit 78.000<br />

1076 -- -- 900 1100 3RW44 66-@BC@6 1 unit 78.000<br />

Order No. supplement for connection types<br />

• With spring-type terminals 2<br />

• With screw terminals 6<br />

Order No. supplement for the rated control supply voltage U 1)<br />

s<br />

• 115 V AC 3<br />

• 230 V AC 4<br />

17-210<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Planning and Configuration with SIRIUS<br />

Introduction<br />

Overview<br />

SIRIUS ES engineering software (E-SW)<br />

The programs of the SIRIUS ES software family enable:<br />

• Clearly arranged configuring of device functions and their parameters<br />

– online and offline<br />

• Efficient diagnostics functions and display of the most important<br />

measured values<br />

• Time savings through shorter startup times.<br />

The SIRIUS ES programs such as Motor Starter ES,<br />

Soft Starter ES and SIMOCODE ES are available in three versions<br />

which differ in user-friendliness, scope of functions and<br />

price (for details see the descriptions of the individual products).<br />

SIRIUS ES Basic Standard Premium<br />

Local interface on the device<br />

(system interface)<br />

Basic functions for parameterizing<br />

the devices<br />

• Parameter assignment<br />

• Operating<br />

• Diagnostics<br />

• Test<br />

Standard functionality<br />

• Parameterizing with the --<br />

integrated graphics editor 1)<br />

• Creating typicals --<br />

• Exporting parameters --<br />

Complete functionality<br />

• Group functions -- --<br />

• S7 Routing -- --<br />

• Teleservice through MPI -- --<br />

• STEP7 Object Manager -- --<br />

PROFIBUS interface -- --<br />

1) Depending on SIRIUS ES program.<br />

Application<br />

In addition to device-specific parameterization, the programs of<br />

the SIRIUS ES software family also provide the following functionality<br />

in a uniform look and feel. These functions are available<br />

in many SIRIUS ES programs.<br />

• Standards-conform printouts<br />

The programs of the SIRIUS ES software family greatly simplify<br />

machine documentation. Parameterization printouts according<br />

to EN ISO 7200 are possible. The elements to be printed<br />

are easy to select and compile as required.<br />

• Easy creation of parameter templates<br />

Parameter templates can be created for devices and applications<br />

with only minimum differences in their parameters. These<br />

templates contain all the parameters which are needed for the<br />

parameterization. In addition it is possible to specify which of<br />

these parameters are fixed and which can be customized,<br />

e. g. by the startup engineer.<br />

• Group function<br />

For the user-friendly parameterization of numerous devices or<br />

applications of the same type, the programs of the SIRIUS ES<br />

software family offer a group function which enables the parameterization<br />

of several devices to be read out or written<br />

through PROFIBUS. In conjunction with templates it is even<br />

possible to selectively adapt the same parameters in any<br />

number of parameterizations.<br />

• Teleservice through MPI<br />

The premium versions of the SIRIUS ES software families support<br />

the use of MPI Teleservice (comprising the Teleservice<br />

software and various Teleservice adapters) for remote diagnostics<br />

of the devices. This facilitates diagnostics and maintenance<br />

and it shortens response times for service purposes.<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-211


Planning and Configuration with SIRIUS<br />

Introduction<br />

Types of delivery and license<br />

The programs of the SIRIUS ES software family are available as<br />

follows:<br />

• Floating license – the license for any one user at any one time<br />

- Authorizes any one user<br />

- Independent of the number of installations (unlike the single<br />

license which is allowed to be installed once only)<br />

- Only the actual use of the program has to be licensed<br />

- Trial license (free use of all program functions for 14 days for<br />

test and evaluation purposes, included on every product<br />

CD, available in the download file of the SIRIUS ES program<br />

in the Service&Support portal).<br />

CONTROL<br />

PRODUCTS<br />

Soft Starter<br />

Control<br />

17<br />

Following delivery versions are available in addition for the programs<br />

of the SIRIUS ES software family:<br />

• Upgrade<br />

Upgrade from an old to a new version with expanded functions,<br />

e. g. upgrade from Motor Starter ES 2006 to<br />

Motor Starter ES 2007<br />

• Powerpack<br />

Special pack for switching within the same software version to<br />

a more powerful version with more functionality,<br />

e. g. Powerpack Motor Starter ES 2007 for switching from<br />

Standard to Premium<br />

• Software Update Service<br />

To keep you up to date at all times we offer a special service<br />

which supplies you automatically with all service packs and<br />

upgrades<br />

Efficient engineering and startup with graphic interfaces and diagnostics<br />

options<br />

17-212<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Planning and Configuration with SIRIUS<br />

Soft Starter ES<br />

Overview<br />

Easy and clearly arranged parameter setting of the 3RW44 soft starter<br />

with Soft Starter ES 2007<br />

Graphic presentation of measured values with the trace function (oscilloscope<br />

function) of Soft Starter ES 2007 Standard and Premium<br />

Soft Starter ES 2007<br />

The Soft Starter ES software permits the quick and easy parameterization,<br />

monitoring and diagnostics of SIRIUS 3RW44 High<br />

Feature soft starters for service purposes. The device parameters<br />

can be configured directly on the PC and transferred to the<br />

soft starter through a serial cable or an optional PROFIBUS interface.<br />

The advantages of Soft Starter ES:<br />

• Clearly arranged configuring of device functions and their parameters<br />

– online and offline<br />

• Effective diagnostics functions on the soft starter and display<br />

of the most important measured values<br />

• Trace function (oscilloscope function) for recording measured<br />

values and events (in the Soft Starter ES Standard and Premium<br />

software versions).<br />

Efficient engineering with new program versions<br />

The Soft Starter ES software program is available in three versions<br />

which differ in their user-friendliness, scope of functions<br />

and price.<br />

Soft starters ES Basic Standard Premium<br />

Access through the local<br />

interface on the device<br />

Parameter assignment<br />

Operating<br />

Diagnostics<br />

Creating templates -- 1)<br />

Exporting parameters --<br />

Comparison functions --<br />

Standards-conform printout --<br />

according to EN ISO 7200<br />

Service data (slave pointer, --<br />

statistics data)<br />

Access through PROFIBUS -- --<br />

Group functions -- --<br />

Teleservice through MPI -- --<br />

S7 Routing -- --<br />

STEP7 Object Manager -- --<br />

1) Templates with Service Pack 1 and higher.<br />

More functions<br />

• Standards-conform printouts<br />

The software tool greatly simplifies machine documentation.<br />

Parameterization printouts according to EN ISO 7200 are possible.<br />

The elements to be printed are easy to select and compile<br />

as required.<br />

• Easy creation of parameter templates<br />

Parameter templates can be created for devices and applications<br />

with only minimum differences in their parameters. These<br />

templates contain all the parameters which are needed for the<br />

parameterization. In addition it is possible to specify which of<br />

these parameters are fixed and which can be adapted, e. g.<br />

by the startup engineer.<br />

• Group function<br />

For the user-friendly parameterization of numerous devices or<br />

applications of the same type, the programs of the SIRIUS ES<br />

software family offer a group function which enables the parameterization<br />

of several devices to be read out or written<br />

through PROFIBUS. In conjunction with typicals it is even possible<br />

to selectively adapt the same parameters in any number<br />

of parameterizations.<br />

• Teleservice through MPI<br />

The Soft Starter ES Premium version supports the use of MPI<br />

Teleservice (comprising the Teleservice software and various<br />

Teleservice adapters) for remote diagnostics of the devices.<br />

This facilitates diagnostics and maintenance, and it shortens<br />

response times for service purposes.<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-213


Planning and Configuration with SIRIUS<br />

Soft Starter ES<br />

Types of delivery and license<br />

Soft Starter ES is available as follows:<br />

• Floating license – the license for any one user at any one time<br />

- Authorizes any one user<br />

- Independent of the number of installations (unlike the single<br />

license which is allowed to be installed once only)<br />

- Only the actual use of the program has to be licensed<br />

- Trial license (free use of all program functions for 14 days for<br />

test and evaluation purposes, included on every product<br />

CD, available in the download file of the SIRIUS ES program<br />

in the Service&Support portal).<br />

Following delivery versions are available in addition for<br />

Soft Starter ES 2007:<br />

• Upgrade<br />

Upgrade from an old to a new version with expanded functions,<br />

e. g. upgrade from Soft Starter ES 2006 to<br />

Soft Starter ES 2007<br />

• Powerpack<br />

Special pack for switching within the same software version to<br />

a more powerful version with more functionality, e. g.<br />

Powerpack Soft Starter ES 2007 for switching from Standard<br />

to Premium<br />

• Software Update Service<br />

To keep you up to date at all times we offer a special service<br />

which supplies you automatically with all service packs and<br />

upgrades<br />

New licensing procedure<br />

To make licensing easier, the three versions of Soft Starter ES are<br />

available with immediate effect with the following license:<br />

14 day trial license for Premium functions:<br />

for test and evaluation purposes, included on every product CD,<br />

available also in the download file of the SIRIUS Soft Starter<br />

ES 2007 program at www.sea.siemens.com/softstarters.<br />

System requirements<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Soft Starter ES 2007 parameterization, start-up and diagnostics<br />

software for the SIRIUS 3RW44 soft starter<br />

Operating system<br />

Processor<br />

RAM<br />

Free space on hard disk<br />

CD-ROM/DVD drive<br />

Serial interface (COM)<br />

PC cable/parameterization cable/connection cable<br />

1) SIRIUS 3RW44 with firmware version ≥ *E04*. Installed in starters<br />

delivered after December 2005.<br />

2) SIRIUS 3RW44 with firmware version ≥ *E06*. Installed in starters delivered<br />

after May 2006.<br />

3) Windows Vista Ultimate 32/ Business 32 from Soft Starter ES 2007+SP1.<br />

Basic/Standard<br />

Selection and ordering data<br />

Parameterization and service software for SIRIUS 3RW44 soft starters<br />

• Can be run under WIN 2000/WIN XP PROF/Windows Vista Ultimate 32/Business 32<br />

• Without PC cable<br />

Premium<br />

Firmware version ≥ *E04* 1) Firmware version ≥ *E06* 2)<br />

Windows 2000 (Service Pack 3 or 4), Windows XP Professional (Service<br />

Pack 2), Windows Vista Ultimate 32/ Business 32 3)<br />

≥ Pentium 800 MHz/≥ 1 GHz (Windows Vista)<br />

≥ 512 MB/≥ 1 GB (Windows Vista)<br />

≥ 150 MB<br />

Yes (only when installing from CD)<br />

PROFIBUS communication module (optional) -- Yes<br />

Yes<br />

Yes<br />

Version Order No. List<br />

Price $<br />

per PU<br />

PS*<br />

Weight<br />

per PU<br />

approx.<br />

kg<br />

Soft Starter ES 2007 Basic<br />

Floating license for one user<br />

E-SW, software and documentation on CD,<br />

3 languages (German/English/French),<br />

communication through system interface<br />

• License key on USB stick, Class A, including CD 3ZS1 313-4CC10-0YA5 1 unit 0.230<br />

Soft Starter ES 2007 Standard<br />

Floating license for one user<br />

E-SW, software and documentation on CD,<br />

3 languages (German/English/French),<br />

communication through system interface<br />

• License key on USB stick, Class A, including CD 3ZS1 313-5CC10-0YA5 1 unit 0.230<br />

17-214<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Planning and Configuration with SIRIUS<br />

Soft Starter ES<br />

Version Order No. List<br />

Price $<br />

per PU<br />

Upgrade for Soft Starter ES 2006<br />

Floating license for one user,<br />

E-SW, software and documentation on CD,<br />

license key on USB stick, Class A,<br />

3 languages (German/English/French),<br />

communication through the system interface<br />

Powerpack for Soft Starter ES 2007 Basic<br />

Floating license for one user,<br />

E-SW, software and documentation on CD,<br />

license key on USB stick, Class A,<br />

3 languages (German/English/French),<br />

communication through the system interface<br />

Software Update Service<br />

For 1 year with automatic extension,<br />

assuming the current software version is in use,<br />

E-SW, software and documentation on CD,<br />

communication through the system interface<br />

PS*<br />

Weight<br />

per PU<br />

approx.<br />

kg<br />

3ZS1 313-5CC10-0YE5 1 unit 0.230<br />

3ZS1 313-5CC10-0YD5 1 unit 0.230<br />

3ZS1 313-5CC10-0YL5 1 unit 0.230<br />

Soft Starter ES 2007 Premium<br />

Floating license for one user<br />

E-SW, software and documentation on CD,<br />

3 languages (German/English/French),<br />

communication through system interface or PROFIBUS<br />

• License key on USB stick, Class A, including CD 3ZS1 313-6CC10-0YA5 1 unit 0.230<br />

Upgrade for Soft Starter ES 2006<br />

Floating license for one user,<br />

E-SW, software and documentation on CD,<br />

license key on USB stick, Class A,<br />

3 languages (German/English/French),<br />

communication through the system interface or<br />

PROFIBUS<br />

3ZS1 313-6CC10-0YE5 1 unit 0.230<br />

PC cables<br />

Powerpack for Soft Starter ES 2007 Standard<br />

Floating license for one user,<br />

E-SW, software and documentation on CD,<br />

license key on USB stick, Class A,<br />

3 languages (German/English/French),<br />

communication through the system interface or<br />

PROFIBUS<br />

Software Update Service<br />

For 1 year with automatic extension,<br />

assuming the current software version is in use,<br />

E-SW, software and documentation on CD,<br />

communication through the system interface or<br />

PROFIBUS<br />

For PC/PG communication with SIRIUS 3RW44 soft<br />

starters<br />

ace, for connecting to<br />

Through the system interf<br />

the serial interface of the PC/PG<br />

3ZS1 313-6CC10-0YD5 1 unit 0.230<br />

3ZS1 313-6CC10-0YL5 1 unit 0.230<br />

3UF7 940-0AA00-0<br />

1 unit 0.150<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

3UF7 940-0AA00-0<br />

Serial/USB<br />

For PC/PG communication<br />

with SIRIUS 3RW44 soft starters<br />

Through the system interface, for connecting to<br />

the USB interface of the PC/PG<br />

3UF7 946-0AA00-0<br />

1 unit 0.150<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-215


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

Accessories<br />

For<br />

soft starters<br />

Type<br />

PROFIBUS communication modules<br />

Version Order No. List<br />

Price $<br />

per PU<br />

Modules can be plugged into the soft starters for<br />

integrating the starters in the PROFIBUS network<br />

with DPV1 slave functionality.<br />

On Y-link the soft starter has only DPV0 slave<br />

functionality.<br />

3RW49 00-0KC00<br />

PS*<br />

Weight<br />

per PU<br />

approx.<br />

kg<br />

1 unit 0.320<br />

3RW49 00-0KC00<br />

Soft Starter<br />

Control<br />

PROFINET communication modules<br />

For 3RW44 soft starter integration in the<br />

PROFINET network, suitable for devices<br />

with firmware version E12 or higher<br />

3RW49 00-0NC00<br />

1 unit 0.320<br />

17<br />

CONTROL<br />

PRODUCTS<br />

3RW49 00-0NC00<br />

External display and operator modules<br />

For indicating and operating the functions provided by 3RW49 00-0AC00 1 unit 0.320<br />

the soft starter using an externally mounted display and<br />

operator module in degree of protection IP54, N1, N12<br />

(e. g. in the control cabinet door)<br />

Connection cables<br />

From the device interface (serial) of the 3RW44 soft<br />

3RW49 00-0AC00 starter to the external display and operator module<br />

• Length 0.5 m, flat 3UF7 932-0AA00-0 1 unit 0.020<br />

• Length 0.5 m, round 3UF7 932-0BA00-0 1 unit 0.050<br />

• Length 1.0 m, round 3UF7 937-0BA00-0 1 unit 0.100<br />

• Length 2.5 m, round 3UF7 933-0BA00-0 1 unit 0.150<br />

Box terminal blocks for soft starters<br />

Box terminal blocks<br />

3RW44 2. Included in the scope of supply<br />

3RW44 3. • Up to 70 mm 2 3RT19 55-4G 1 unit 0.230<br />

• Up to 120 mm 2 3RT19 56-4G 1 unit 0.260<br />

3RW44 4. • Up to 240 mm 2 3RT19 66-4G 1 unit 0.676<br />

3RT19<br />

17-216<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

Spare parts<br />

For<br />

soft starters<br />

Version Order No. List<br />

Price $<br />

per PU<br />

PS*<br />

Weight<br />

per PU<br />

approx.<br />

kg<br />

Type<br />

Covers for soft starters<br />

Terminal covers for box terminals<br />

Additional touch protection to be fitted at the box terminals<br />

(2 units required per device)<br />

3RW44 2. and<br />

3RT19 56-4EA2 1 unit 0.030<br />

3RW44 3.<br />

3RW44 4. 3RT19 66-4EA2 1 unit 0.040<br />

Terminal covers for cable lugs and busbar<br />

connections<br />

3RW44 2. and<br />

3RT19 56-4EA1 1 unit 0.070<br />

3RW44 3.<br />

3RW44 4. 3RT19 66-4EA1 1 unit 0.130<br />

3RT19 .6-4EA1<br />

Operating instructions 1)<br />

Fans<br />

3RW49<br />

For 3RW44 soft starters<br />

Fans<br />

3RW44 2. and<br />

3RW44 3.<br />

3ZX10 12-0RW44-1AA1<br />

115 V AC 3RW49 36-8VX30 1 unit 0.300<br />

230 V AC 3RW49 36-8VX40 1 unit 0.300<br />

3RW44 4. 115 V AC 3RW49 47-8VX30 1 unit 0.500<br />

230 V AC 3RW49 47-8VX40 1 unit 0.500<br />

3RW44 115 V AC 3RW49 57-8VX30 1 unit 0.800<br />

3RW44 6. 2) 5. and 230 V AC 3RW49 57-8VX40 1 unit 0.800<br />

3RW44 6. 3) 115 V AC 3RW49 66-8VX30 1 unit 0.300<br />

230 V AC 3RW49 66-8VX40 1 unit 0.300<br />

Soft Starter<br />

Control<br />

1) The operating instructions are included in the scope of supply.<br />

2) 3RW44 6. mounting on output side.<br />

3) For mounting on front side.<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-217


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

More information<br />

Application examples for normal starting (Class 10)<br />

Normal starting Class 10 (up to 20 s with 350 % I n motor ),<br />

The soft starter rating can be selected to be as high as the rating of the motor used.<br />

Application Conveyor belt Roller conveyor Compressor Small fan Pump Hydraulic pump<br />

Starting parameters 1)<br />

• Voltage ramp and current<br />

limiting<br />

- Starting voltage % 70 60 50 30 30 30<br />

- Starting time s 10 10 10 10 10 10<br />

- Current limit value Deactivated Deactivated 4 x I M 4 x I M Deactivated Deactivated<br />

• Torque ramp<br />

- Starting torque 60 50 40 20 10 10<br />

- End torque 150 150 150 150 150 150<br />

- Starting time 10 10 10 10 10 10<br />

• Breakaway pulse<br />

Deactivated (0 ms) Deactivated (0 ms) Deactivated (0 ms) Deactivated (0 ms) Deactivated (0 ms) Deactivated (0 ms)<br />

Ramp-down mode<br />

Smooth rampdown<br />

Smooth rampdown<br />

Free ramp-down Free ramp-down Pump ramp-down Free ramp-down<br />

Soft Starter<br />

Control<br />

Application examples for heavy starting (Class 20)<br />

Heavy starting Class 20 (up to 40 s with 350 % I n motor ),<br />

The soft starter has to be selected one rating class higher than the motor used.<br />

Application Mixer Centrifuge Milling machine<br />

Starting parameters 1)<br />

• Voltage ramp and current<br />

limiting<br />

- Starting voltage % 30 30 30<br />

- Starting time s 30 30 30<br />

- Current limit value 4 x I M 4 x I M 4 x I M<br />

• Torque ramp<br />

- Starting torque 30 30 30<br />

- End torque 150 150 150<br />

- Starting time 30 30 30<br />

• Breakaway pulse Deactivated (0 ms) Deactivated (0 ms) Deactivated (0 ms)<br />

Ramp-down mode Free ramp-down Free ramp-down Free ramp-down or DC braking<br />

Application examples for very heavy starting (Class 30)<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Very heavy starting Class 30 (up to 60 s with 350 % I n motor ),<br />

The soft starter has to be selected two rating classes higher than the motor used.<br />

Application Large fan Mill Crushers Circular saw/bandsaw<br />

Starting parameters 1)<br />

• Voltage ramp and current<br />

limiting<br />

- Starting voltage % 30 50 50 30<br />

- Starting time s 60 60 60 60<br />

- Current limit value 4 x I M 4 x I M 4 x I M 4 x I M<br />

• Torque ramp<br />

- Starting torque 20 50 50 20<br />

- End torque 150 150 150 150<br />

- Starting time 60 60 60 60<br />

• Breakaway pulse Deactivated (0 ms) 80 %, 300 ms 80 %, 300 ms Deactivated (0 ms)<br />

Ramp-down mode Free ramp-down Free ramp-down Free ramp-down Free ramp-down<br />

Note:<br />

These tables present sample set values and device sizes. They<br />

are intended only for the purposes of information and are not<br />

binding. The set values depend on the application in question<br />

and must be optimized during start-up.<br />

The soft starter dimensions should be checked where necessary<br />

with the Win-Soft Starter software or with the help of Technical<br />

Assistance.<br />

1) Actual motor starting times are load dependent.<br />

17-218<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

Circuit concept<br />

The SIRIUS 3RW44 soft starters can be operated in two different<br />

types of circuit.<br />

• Inline circuit<br />

The controls for isolating and protecting the motor are simply<br />

connected in series with the soft starter. The motor is connected<br />

to the soft starter with three cables.<br />

• Inside-delta circuit<br />

The wiring is similar to that of wye-delta starters. The phases of<br />

the soft starter are connected in series with the individual motor<br />

windings. The soft starter then only has to carry the phase current,<br />

amounting to about 58 % of the rated motor current (conductor<br />

current).<br />

Comparison of the types of circuit<br />

Inline circuit:<br />

Rated current I e corresponds to the rated motor current I n ,<br />

3 cables to the motor<br />

Configuration<br />

The 3RW44 solid-state soft starters are designed for normal<br />

starting. In case of heavy starting or increased starting frequency,<br />

a larger device must be selected.<br />

For long starting times it is recommended to have a PTC sensor<br />

in the motor. This also applies for the ramp-down modes smooth<br />

ramp-down, pump ramp-down and DC braking, because during<br />

the ramp-down time in these modes, an additional current loading<br />

applies in contrast to free ramp-down.<br />

In the motor feeder between the SIRIUS 3RW soft starter and the<br />

motor, no capacitive elements are permitted (e. g. no reactivepower<br />

compensation equipment). In addition, neither static systems<br />

for reactive-power compensation nor dynamic PFC (Power<br />

Factor Correction) must be operated in parallel during starting<br />

and ramp-down of the soft starter. This is important to prevent<br />

faults arising on the compensation equipment and/or the soft<br />

starter.<br />

All elements of the main circuit (such as fuses and controls)<br />

should be dimensioned for direct starting, following the local<br />

short-circuit conditions. Fuses, controls and overload relays<br />

must be ordered separately.<br />

A bypass contact system and solid-state overload relay are already<br />

integrated in the 3RW44 soft starter and therefore do not<br />

have to be ordered separately.<br />

The harmonic component load for starting currents must be<br />

taken into consideration for the selection of motor starter protectors<br />

(selection of release).<br />

Note:<br />

When induction motors are switched on, voltage drops normally<br />

appear on starters of all types (direct starters, wye-delta starters,<br />

soft starters). The infeed transformer must always be dimensioned<br />

such that the voltage dip when starting the motor remains<br />

within the permissible tolerance. If the infeed transformer is dimensioned<br />

with only a small margin, it is best for the control voltage<br />

to be supplied from a separate circuit (independently of the<br />

main voltage) in order to avoid the potential switching off of the<br />

soft starter.<br />

Device interface, PROFIBUS DP communication module,<br />

Soft Starter ES parameterizing and operating software<br />

The 3RW44 electronic soft starters have a PC interface for communicating<br />

with the Soft Starter ES software or for connecting<br />

the external display and operator module. If the optional<br />

PROFIBUS communication module is used, the 3RW44 soft<br />

starter can be integrated in the PROFIBUS network and communicate<br />

using the GSD file or Soft Starter ES Premium software.<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Inside-delta circuit:<br />

Rated current I e corresponds to approx. 58 % of the rated motor<br />

current I n , 6 cables to the motor (as with wye-delta starters)<br />

Which circuit?<br />

Using the inline circuit involves the lowest wiring outlay. If the soft<br />

starter to motor connections are long, this circuit is preferable.<br />

With the inside-delta circuit there is double the wiring complexity<br />

but a smaller size of device can be used at the same rating. It is<br />

also recommended to use an isolating contactor in series with<br />

each motor winding.<br />

Thanks to the choice of operating mode between the inline circuit<br />

and inside-delta circuit, it is always possible to select the<br />

most favorable solution.<br />

The braking function is possible only in the inline circuit.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-219


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

CONTROL<br />

PRODUCTS<br />

17<br />

Soft Starter<br />

Control<br />

System Manual for SIRIUS 3RW44<br />

Besides containing all important information on configuring,<br />

commissioning and servicing, the manual also contains example<br />

circuits and the technical specifications for all devices. This<br />

manual can be downloaded off the internet.<br />

Win-Soft Starter selection and simulation program<br />

With this software, you can simulate and select all Siemens soft<br />

starters, taking into account various parameters such as mains<br />

properties, motor and load data, and special application<br />

requirements.<br />

The software is a valuable tool, which makes complicated,<br />

lengthy manual calculations for determining the required soft<br />

starters superfluous.<br />

The Win-Soft Starter selection and simulation program can be<br />

downloaded free of charge from:<br />

www.usa.siemens.com/softstarters > Software<br />

More information can be found on the Internet at:<br />

www.usa.siemens.com/softstarters<br />

17-220<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

Revised on 12/11/17<br />

Soft starters for enclosed applications<br />

Overview<br />

The family of 3RW40 and 3RW44 softstarters are available in<br />

stand alone enclosed control designs for smooth starting and<br />

stopping of standard NEMA design B three phase inductive motors,<br />

thus eliminating physical stresses to the system and load<br />

while minimizing starting current. These pre-engineered enclosed<br />

designs offer convenience and flexibility in and UL/CSA<br />

certified offering. Enclosed styles are available in combination<br />

and non-combination configurations through 600HP and system<br />

voltages of 200V, 230V, 480V, and 600V.<br />

The Class 73 offers either the 3RW40 or 3RW44 in a non-combination<br />

style offering. These non-combination styles come standard<br />

with a choice of Type 1, 3R, 12, 4 NEMA rated enclosure, a<br />

control transformer, Sirius softstarter with built-in overload and<br />

bypass, line side power terminal block, and a reset pushbutton.<br />

The enclosed offering can be powerfully matched with a wide<br />

variety of factory modified options such as pushbutton control,<br />

pilot lights, metering and other control options such as isolation<br />

contactors and emergency start bypass starters. 3RW44 enclosed<br />

styles are also available with optional through the door<br />

keypad and Profibus communication.<br />

The Class 74 offering includes all of the features of the Class 73<br />

in a combination style design. Standard options are either a circuit<br />

breaker or fusible disconnect providing short circuit protection<br />

and soft starting in one package.<br />

Application<br />

The Class 73/74 product is a fully enclosed solid state reduced<br />

voltage starter designed for a wide variety of industrial applications.<br />

The enclosed softstarter offerings are ideal for new as well<br />

as existing applications where total motor controls is required.<br />

Proper selection based on application data is made simple following<br />

these easy steps:<br />

- Select proper RVSS by application<br />

• Select the 3RW40 versus the 3RW44 using the application<br />

info provided in the open section of the catalog<br />

- Select the rating chart for normal starting or sever duty starting<br />

• Normal starting is rated at 350% of rated motor current<br />

IM for 10 seconds and based on starts per hour – representative<br />

of a class 20 application.<br />

• Severe starting is rated at 350% of rated motor current<br />

Im for 20 seconds and based on starts per hour – representative<br />

of a Class 20 application<br />

- Select model using Motor nameplate data<br />

• Identify correct motor voltage column<br />

• Select rate current or HP row<br />

• Find ordering number under desired enclosure type<br />

column (e.g. NEMA 1)<br />

• Select appropriate system voltage<br />

- Select factory modification on page 6/40 1)<br />

Example:<br />

3RW44, N12, CB disconnect, 460V, 200HP with a start/stop and<br />

red run light<br />

Order No.<br />

74MT34BFAP A1 FC<br />

Soft Starter<br />

Control<br />

Product Nomenclature<br />

Class 73 and 74 Enclosed Soft Starters<br />

Class<br />

73 = Non-combination type<br />

74 = Combination type<br />

Size + Model Rating (Amps)<br />

3RW40<br />

AR = 11<br />

BR = 23<br />

CR = 29<br />

DR = 34<br />

ER = 42<br />

FR = 58<br />

GR = 62<br />

HR = 73<br />

JR = 98<br />

AS = 117<br />

BS = 145<br />

CS = 205<br />

DS = 248<br />

ES = 315<br />

FS = 385<br />

3RW44<br />

AT = 26<br />

BT = 32<br />

CT = 42<br />

DT = 51<br />

ET = 68<br />

FT = 82<br />

GT = 100<br />

HT = 117<br />

JT = 145<br />

KT = 180<br />

LT = 215<br />

MT = 280<br />

NT = 315<br />

PT = 385<br />

QT = 494<br />

RT = 551<br />

ST = 615<br />

TT = 693<br />

WT = 780<br />

YT = 970<br />

ZT = 1076<br />

Phases<br />

3 = 3 phase<br />

Supply Voltage<br />

6 = 200<br />

2 = 230<br />

3 = 380/415<br />

4 = 460<br />

5 = 575<br />

Enclosure Type<br />

B = NEMA 1<br />

0 = NEMA 12<br />

D = NEMA 3R<br />

E = NEMA 4<br />

W = NEMA 4X SS<br />

Mod Box Type<br />

F = Standard<br />

G = Modified<br />

Control Voltage<br />

A = None<br />

Disconnect Type<br />

Blank = None<br />

P = MCP<br />

T = Thermal Magnetic<br />

F = Fusible<br />

17 CONTROL<br />

PRODUCTS<br />

1)<br />

Some modifications will require a larger ‘Modified’ box than the standard box<br />

e.g. Isolation contactor, space heater, etc. See page 17-234 for instructions.<br />

Product Category: IEC<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-221


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW40 Size S0-S3 Non-Combo<br />

Ordering Information<br />

Enclosed devices should be ordered by<br />

the FLA of the motor.<br />

The 3RW40 is designed for normal<br />

starting applications.<br />

For factory modifications see page 17-234.<br />

For complete derating and application info<br />

see page 17-250<br />

For dimensional drawings see page 17-286.<br />

Ideal applications for 3RW40 enclosed<br />

softstarters<br />

b Fans<br />

b Pumps<br />

b Easy starting loads starting in less than<br />

10 seconds<br />

Class 73 starters are built to UL and CSA<br />

standards<br />

Soft Starter<br />

Control<br />

3RW40 Enclosed features:<br />

b Available in NEMA 1,12,3R,4, and<br />

4 stainless steel<br />

b Compact size<br />

b Built-in Bypass contactor<br />

b Voltage ramp up and ramp down<br />

b Current limit adjustment of 125 - 550%<br />

b Internal overload class 10,15,or 20<br />

b Internal self protection<br />

b Fault monitoring<br />

b Isolation Contactor<br />

3RW40 for Standard Applications<br />

Enclosed Non-Combination (Starter Only)<br />

Class 73 non-combination starters include:<br />

b NEMA rated enclosure<br />

b 3RW40 Sirius softstarter with built-in OL<br />

and bypass<br />

b Control Circuit Transformer<br />

b Line side power terminal block<br />

b Reset button<br />

b Isolation Contactor<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Rated<br />

MAX HP a KW Class 10 Light Duty (350% * Ie for 10s) b<br />

Operating OPEN Style List List List List NEMA 4/4X List<br />

Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $<br />

11 3 3 7.5 — 6 3RW4024-1BB14 73AR3_BFA 73AR3_DFA 73AR3_0FA 73AR3_EFA 73AR3_WFA<br />

23 5 7.5 15 — 13 3RW4026-1BB14 73BR3_BFA 73BR3_DFA 73BR3_0FA 73BR3_EFA 73BR3_WFA<br />

29 7.5 10 20 — 16 3RW4027-1BB14 73CR3_BFA 73CR3_DFA 73CR3_0FA 73CR3_EFA 73CR3_WFA<br />

34 10 10 25 — 18 3RW4028-1BB14 73DR3_BFA 73DR3_DFA 73DR3_0FA 73DR3_EFA 73DR3_WFA<br />

42 10 15 30 — 23 3RW4036-1BB14 73ER3_BFA 73ER3_DFA 73ER3_0FA 73ER3_EFA 73ER3_WFA<br />

58 15 20 40 — 31 3RW4037-1BB14 73FR3_BFA 73FR3_DFA 73FR3_0FA 73FR3_EFA 73FR3_WFA<br />

62 20 20 40 — 33 3RW4038-1BB14 73GR3_BFA 73GR3_DFA 73GR3_0FA 73GR3_EFA 73GR3_WFA<br />

73 20 25 50 — 39 3RW4046-1BB14 73HR3_BFA 73HR3_DFA 73HR3_0FA 73HR3_EFA 73HR3_WFA<br />

98 30 30 75 — 52 3RW4047-1BB14 73JR3_BFA 73JR3_DFA 73JR3_0FA 73JR3_EFA 73JR3_WFA<br />

200V 6 6 6 6 6<br />

230V 2 2 2 2 2<br />

380V 3 3 3 3 3<br />

460V 4 4 4 4 4<br />

a Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor.<br />

HPs are for reference only. Enclosed ratings are at 40°C<br />

Starter selection is dependent on type of application. Ie = FLA rating of motor<br />

17-222<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: IEC


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

Enclosed 3RW40<br />

3RW40 Enclosed features:<br />

b Available in NEMA 1, 12, 3R, 4, and 4<br />

stainless steel<br />

b Compact size<br />

b Built-in bypass contactor<br />

b Voltage ramp up and ramp down<br />

b Current limit adjustment of 125 - 550%<br />

b Internal overload class 10, 15, or 20<br />

b Internal self protection<br />

b Fault monitoring<br />

Ordering Information<br />

Enclosed devices should be ordered by<br />

the FLA of the motor.<br />

The 3RW40 is designed for normal<br />

starting applications (Class 10<br />

applications).<br />

For factory modifications see page 17-234.<br />

For complete derating and application info<br />

see page 17-250.<br />

For dimensional drawings see page 17-286.<br />

Class 73 non-combination starters include:<br />

b NEMA rated enclosure<br />

b 3RW40 Sirius softstarter with built-in OL<br />

and bypass<br />

b Control circuit transformer<br />

b Line side power terminal block<br />

b Reset button<br />

For all technical information, please consult the 2006 Industrial Controls Catalog or contact your local sales support center.<br />

3RW40 for Standard Applications<br />

Enclosed Non-Combination (Starter Only)<br />

Ideal applications for 3RW40 enclosed<br />

softstarters:<br />

b Fans<br />

b Pumps<br />

b Building/construction machines<br />

b Presses<br />

b Escalators<br />

b Transport systems<br />

b Air conditioning systems<br />

b Ventilators<br />

b Assembly lines<br />

Class 73 starters are built to UL and<br />

CSA standards.<br />

Rated<br />

MAX HP a KW Class 10 Light Duty (350% * Im for 10s) b<br />

Operating OPEN Style List List List List NEMA 4/4X List<br />

Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $<br />

117 30 40 75 — 56 3RW4055-6BB34 73AS3_BFA 73AS3_DFA 73AS3_0FA 73AS3_EFA 73AS3_WFA<br />

145 40 50 100 — 75 3RW4056-6BB34 73BS3_BFA 73BS3_DFA 73BS3_0FA 73BS3_EFA 73BS3_WFA<br />

205 60 75 150 — 112 3RW4073-6BB34 73CS3_BFA 73CS3_DFA 73CS3_0FA 73CS3_EFA 73CS3_WFA<br />

248 75 100 200 — 149 3RW4074-6BB34 73DS3_BFA 73DS3_DFA 73DS3_0FA 73DS3_EFA 73DS3_WFA<br />

315 100 125 250 — 186 3RW4075-6BB34 73ES3_BFA 73ES3_DFA 73ES3_0FA 73ES3_EFA 73ES3_WFA<br />

385 125 150 300 — 224 3RW4076-6BB34 73FS3_BFA 73FS3_DFA 73FS3_0FA 73FS3_EFA 73FS3_WFA<br />

200V 6 6 6 6 6<br />

230V 2 2 2 2 2<br />

380V 3 3 3 3 3<br />

460V 4 4 4 4 4<br />

117 — — 75 100 — 3RW4055-6BB35 73AS35BFA 73AS35DFA 73AS350FA 73AS35EFA 73AS35WFA<br />

145 — — 100 150 — 3RW4056-6BB35 73BS35BFA 73BS35DFA 73BS350FA 73BS35EFA 73BS35WFA<br />

205 — — 150 200 — 3RW4073-6BB35 73CS35BFA 73CS35DFA 73CS350FA 73CS35EFA 73CS35WFA<br />

248 — — 200 250 — 3RW4074-6BB35 73DS35BFA 73DS35DFA 73DS350FA 73DS35EFA 73DS35WFA<br />

315 — — 250 300 — 3RW4075-6BB35 73ES35BFA 73ES35DFA 73ES350FA 73ES35EFA 73ES35WFA<br />

385 — — 300 400 — 3RW4076-6BB35 73FS35BFA 73FS35DFA 73FS350FA 73FS35EFA 73FS35WFA<br />

Enclosed Non-Combination (Starter Only)<br />

Rated<br />

MAX HP a KW Class 20 Severe Duty (350% * Ie for 20s) b<br />

Operating OPEN Style List List List List NEMA 4/4X List<br />

Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $<br />

112 30 40 75 — 56 3RW4055-6BB34 73AS3_BFA 73AS3_DFA 73AS3_0FA 73AS3_EFA 73AS3_WFA<br />

132 40 50 100 — 75 3RW4056-6BB34 73BS3_BFA 73BS3_DFA 73BS3_0FA 73BS3_EFA 73BS3_WFA<br />

185 60 60 125 — 93 3RW4073-6BB34 73CS3_BFA 73CS3_DFA 73CS3_0FA 73CS3_EFA 73CS3_WFA<br />

205 60 75 150 — 112 3RW4074-6BB34 73DS3_BFA 73DS3_DFA 73DS3_0FA 73DS3_EFA 73DS3_WFA<br />

280 75 100 200 — 149 3RW4075-6BB34 73ES3_BFA 73ES3_DFA 73ES3_0FA 73ES3_EFA 73ES3_WFA<br />

340 100 125 250 — 186 3RW4076-6BB34 73FS3_BFA 73FS3_DFA 73FS3_0FA 73FS3_EFA 73FS3_WFA<br />

200V 6 6 6 6 6<br />

230V 2 2 2 2 2<br />

380V 3 3 3 3 3<br />

460V 4 4 4 4 4<br />

112 — — 75 75 — 3RW4055-6BB35 73AS35BFA 73AS35DFA 73AS350FA 73AS35EFA 73AS35WFA<br />

132 — — 100 125 — 3RW4056-6BB35 73BS35BFA 73BS35DFA 73BS350FA 73BS35EFA 73BS35WFA<br />

185 — — 125 150 — 3RW4073-6BB35 73CS35BFA 73CS35DFA 73CS350FA 73CS35EFA 73CS35WFA<br />

205 — — 150 200 — 3RW4074-6BB35 73DS35BFA 73DS35DFA 73DS350FA 73DS35EFA 73DS35WFA<br />

280 — — 200 250 — 3RW4075-6BB35 73ES35BFA 73ES35DFA 73ES350FA 73ES35EFA 73ES35WFA<br />

340 — — 250 300 — 3RW4076-6BB35 73FS35BFA 73FS35DFA 73FS350FA 73FS35EFA 73FS35WFA<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

a Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor.<br />

HPs are for reference only. Enclosed ratings are at 40°C.<br />

b Starter selection is dependent on type of application. Im = FLA rating of motor.<br />

Product Category: IEC<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-223


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW40 Size S0-S3 Circuit Breaker<br />

Ordering Information<br />

Enclosed devices should be ordered by<br />

the FLA of the motor.<br />

The 3RW40 is designed for normal<br />

starting applications.<br />

For factory modifications see page 17-234.<br />

For complete derating and application info<br />

see page 17-250<br />

For dimensional drawings see page 17-286.<br />

Ideal applications for 3RW40 enclosed<br />

softstarters<br />

b Fans<br />

b Pumps<br />

b Easy starting loads starting in less than<br />

10 seconds<br />

Class 74 starters are built to UL and CSA<br />

standards<br />

Soft Starter<br />

Control<br />

3RW40 Enclosed features:<br />

b Available in NEMA 1, 12, 3R, 4, and<br />

4 stainless steel<br />

b Compact size<br />

b Built-in Bypass contactor<br />

b Voltage ramp up and ramp down<br />

b Current limit adjustment of 125 - 550%<br />

b Internal overload class 10, 15, or 20<br />

b Internal self protection<br />

b Fault monitoring<br />

b Isolation Contactor<br />

3RW40 for Standard Applications<br />

Class 74 non-combination starters include:<br />

b NEMA rated enclosure<br />

b Circuit Breaker disconnect with shunt trip<br />

b 3RW40 Sirius softstarter with built-in OL<br />

and bypass<br />

b Control Circuit Transformer<br />

b Isolation Contactor<br />

Enclosed Circuit Breaker Combination (Starter With Circuit Breaker Disconnect)<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Rated<br />

MAX HP a KW Class 10 Light Duty (350% * Ie for 10s) b<br />

Operating OPEN Style List List List List NEMA 4/4X List<br />

Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $<br />

11 3 3 7.5 — 6 3RW4024-1BB14 74AR3_BFAP 74AR3_DFAP 74AR3_0FAP 74AR3_EFAP 74AR3_WFAP<br />

23 5 7.5 15 — 13 3RW4026-1BB14 74BR3_BFAP 74BR3_DFAP 74BR3_0FAP 74BR3_EFAP 74BR3_WFAP<br />

29 7.5 10 20 — 16 3RW4027-1BB14 74CR3_BFAP 74CR3_DFAP 74CR3_0FAP 74CR3_EFAP 74CR3_WFAP<br />

34 10 10 25 — 18 3RW4028-1BB14 74DR3_BFAP 74DR3_DFAP 74DR3_0FAP 74DR3_EFAP 74DR3_WFAP<br />

42 10 15 30 — 23 3RW4036-1BB14 74ER3_BFAP 74ER3_DFAP 74ER3_0FAP 74ER3_EFAP 74ER3_WFAP<br />

58 15 20 40 — 31 3RW4037-1BB14 74FR3_BFAP 74FR3_DFAP 74FR3_0FAP 74FR3_EFAP 74FR3_WFAP<br />

62 20 20 40 — 33 3RW4038-1BB14 74GR3_BFAP 74GR3_DFAP 74GR3_0FAP 74GR3_EFAP 74GR3_WFAP<br />

73 20 25 50 — 39 3RW4046-1BB14 74HR3_BFAP 74HR3_DFAP 74HR3_0FAP 74HR3_EFAP 74HR3_WFAP<br />

98 30 30 75 — 52 3RW4047-1BB14 74JR3_BFAP 74JR3_DFAP 74JR3_0FAP 74JR3_EFAP 74JR3_WFAP<br />

200V 6 6 6 6 6<br />

230V 2 2 2 2 2<br />

380V 3 3 3 3 3<br />

460V 4 4 4 4 4<br />

a Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor.<br />

HPs are for reference only. Enclosed ratings are at 40°C<br />

Starter selection is dependent on type of application. Ie = FLA rating of motor<br />

17-224<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: IEC


Control Products<br />

Enclosed 3RW44<br />

3RW40 Enclosed features:<br />

b Available in NEMA 1, 12, 3R, 4, and 4<br />

stainless steel<br />

b Compact size<br />

b Built-in bypass contactor<br />

b Voltage ramp up and ramp down<br />

b Current limit adjustment of 125 - 550%<br />

b Internal overload class 10, 15, or 20<br />

b Internal self protection<br />

b Fault monitoring<br />

3RW40 for Standard Applications<br />

Ordering Information<br />

Enclosed devices should be ordered by<br />

the FLA of the motor.<br />

The 3RW40 is designed for normal<br />

starting applications (Class 10<br />

applications).<br />

For factory modifications see page 17-234.<br />

For complete derating and application info<br />

see page 17-261.<br />

For dimensional drawings see page 17-286.<br />

Class 74 non-combination starters include:<br />

b NEMA rated enclosure<br />

b Circuit breaker disconnect with shunt trip<br />

b 3RW40 Sirius softstarter with built-in OL<br />

and bypass<br />

b Control circuit transformer<br />

For all technical information, please consult the 2006 Industrial Controls Catalog or contact your local sales support center.<br />

Enclosed Circuit Breaker Combination (Starter with Circuit Breaker Disconnect)<br />

Ideal applications for 3RW40 enclosed<br />

softstarters:<br />

b Fans<br />

b Pumps<br />

b Building/construction machines<br />

b Presses<br />

b Escalators<br />

b Transport systems<br />

b Air conditioning systems<br />

b Ventilators<br />

b Assembly lines<br />

Class 74 starters are built to UL and CSA<br />

standards.<br />

Rated<br />

MAX HP a KW Class 10 Light Duty (350% * Im for 10s) b<br />

Operating OPEN Style List List List List NEMA 4/4X List<br />

Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $<br />

117 30 40 75 — 56 3RW4055-6BB34 74AS3_BFAP 74AS3_DFAP 74AS3_0FAP 74AS3_EFAP 74AS3_WFAP<br />

145 40 50 100 — 75 3RW4056-6BB34 74BS3_BFAP 74BS3_DFAP 74BS3_0FAP 74BS3_EFAP 74BS3_WFAP<br />

205 60 75 150 — 112 3RW4073-6BB34 74CS3_BFAP 74CS3_DFAP 74CS3_0FAP 74CS3_EFAP<br />

248 75 100 200 — 149 3RW4074-6BB34 74DS3_BFAP 74DS3_DFAP 74DS3_0FAP 74DS3_EFAP<br />

315 100 125 250 — 186 3RW4075-6BB34 74ES3_BFAP 74ES3_DFAP 74ES3_0FAP 74ES3_EFAP<br />

385 125 150 300 — 224 3RW4076-6BB34 74FS3_BFAP 74FS3_DFAP 74FS3_0FAP 74FS3_EFAP<br />

200V 6 6 6 6 6<br />

230V 2 2 2 2 2<br />

380V 3 3 3 3 3<br />

460V 4 4 4 4 4<br />

117 — — 75 100 — 3RW4055-6BB35 74AS35BFAP 74AS35DFAP 74AS350FAP 74AS35EFAP 74AS35WFAP<br />

145 — — 100 150 — 3RW4056-6BB35 74BS35BFAP 74BS35DFAP 74BS350FAP 74BS35EFAP 74BS35WFAP<br />

205 — — 150 200 — 3RW4073-6BB35 74CS35BFAP 74CS35DFAP 74CS350FAP 74CS35EFAP<br />

248 — — 200 250 — 3RW4074-6BB35 74DS35BFAP 74DS35DFAP 74DS350FAP 74DS35EFAP<br />

315 — — 250 300 — 3RW4075-6BB35 74ES35BFAP 74ES35DFAP 74ES350FAP 74ES35EFAP<br />

385 — — 300 400 — 3RW4076-6BB35 74FS35BFAP 74FS35DFAP 74FS350FAP 74FS35EFAP<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Enclosed Circuit Breaker Combination (Starter with Circuit Breaker Disconnect)<br />

Rated<br />

MAX HP a KW Class 20 Severe Duty (350% * Ie for 20s) b<br />

Operating OPEN Style List List List List NEMA 4/4X List<br />

Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $<br />

112 30 40 75 — 56 3RW4055-6BB34 74AS3_BFAP 74AS3_DFAP 74AS3_0FAP 74AS3_EFAP 74AS3_WFAP<br />

132 40 50 100 — 75 3RW4056-6BB34 74BS3_BFAP 74BS3_DFAP 74BS3_0FAP 74BS3_EFAP 74BS3_WFAP<br />

185 60 60 125 — 93 3RW4073-6BB34 74CS3_BFAP 74CS3_DFAP 74CS3_0FAP 74CS3_EFAP<br />

205 60 75 150 — 112 3RW4074-6BB34 74DS3_BFAP 74DS3_DFAP 74DS3_0FAP 74DS3_EFAP<br />

280 75 100 200 — 149 3RW4075-6BB34 74ES3_BFAP 74ES3_DFAP 74ES3_0FAP 74ES3_EFAP<br />

340 100 125 250 — 186 3RW4076-6BB34 74FS3_BFAP 74FS3_DFAP 74FS3_0FAP 74FS3_EFAP<br />

200V 6 6 6 6 6<br />

230V 2 2 2 2 2<br />

380V 3 3 3 3 3<br />

460V 4 4 4 4 4<br />

112 — — 75 75 — 3RW4055-6BB35 74AS35BFAP 74AS35DFAP 74AS350FAP 74AS35EFAP 74AS35WFAP<br />

132 — — 100 125 — 3RW4056-6BB35 74BS35BFAP 74BS35DFAP 74BS350FAP 74BS35EFAP 74BS35WFAP<br />

185 — — 125 150 — 3RW4073-6BB35 74CS35BFAP 74CS35DFAP 74CS350FAP 74CS35EFAP<br />

205 — — 150 200 — 3RW4074-6BB35 74DS35BFAP 74DS35DFAP 74DS350FAP 74DS35EFAP<br />

280 — — 200 250 — 3RW4075-6BB35 74ES35BFAP 74ES35DFAP 74ES350FAP 74ES35EFAP<br />

340 — — 250 300 — 3RW4076-6BB35 74FS35BFAP 74FS35DFAP 74FS350FAP 74FS35EFAP<br />

a Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor.<br />

HPs are for reference only. Enclosed ratings are at 40°C.<br />

b Starter selection is dependent on type of application. Im = FLA rating of motor.<br />

Product Category: IEC<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-225


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW40 Size S0-S3 Fusible<br />

Ordering Information<br />

Enclosed devices should be ordered by<br />

the FLA of the motor.<br />

The 3RW40 is designed for normal<br />

starting applications.<br />

For factory modifications see page 17-234.<br />

For complete derating and application info<br />

see page 17-250<br />

For dimensional drawings see page 17-286.<br />

Ideal applications for 3RW40 enclosed<br />

softstarters<br />

b Fans<br />

b Pumps<br />

b Easy starting loads starting in less than<br />

10 seconds<br />

Class 74 starters are built to UL and CSA<br />

standards<br />

Soft Starter<br />

Control<br />

3RW40 Enclosed features:<br />

b Available in NEMA 1, 12, 3R, 4, and<br />

4 stainless steel<br />

b Compact size<br />

b Built-in Bypass contactor<br />

b Voltage ramp up and ramp down<br />

b Current limit adjustment of 125 - 550%<br />

b Internal overload class 10,15,or 20<br />

b Internal self protection<br />

b Fault monitoring<br />

b Isolation Contactor<br />

3RW40 for Standard Applications<br />

Class 73 non-combination starters include:<br />

b NEMA rated enclosure<br />

b Fusible Disconnect<br />

b 3RW40 Sirius softstarter with built-in<br />

OL and bypass<br />

b Control Circuit Transformer<br />

b Isolation Contactor<br />

Enclosed Fusible Combination (Starter With Fusible Disconnect)<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Rated<br />

MAX HP a KW Class 10 Light Duty (350% * Ie for 10s) b<br />

Operating OPEN Style List List List List NEMA 4/4X List<br />

Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $<br />

11 3 3 7.5 — 6 3RW4024-1BB14 74AR3_BFAF 74AR3_DFAF 74AR3_0FAF 74AR3_EFAF 74AR3_WFAF<br />

23 5 7.5 15 — 13 3RW4026-1BB14 74BR3_BFAF 74BR3_DFAF 74BR3_0FAF 74BR3_EFAF 74BR3_WFAF<br />

29 7.5 10 20 — 16 3RW4027-1BB14 74CR3_BFAF 74CR3_DFAF 74CR3_0FAF 74CR3_EFAF 74CR3_WFAF<br />

34 10 10 25 — 18 3RW4028-1BB14 74DR3_BFAF 74DR3_DFAF 74DR3_0FAF 74DR3_EFAF 74DR3_WFAF<br />

42 10 15 30 — 23 3RW4036-1BB14 74ER3_BFAF 74ER3_DFAF 74ER3_0FAF 74ER3_EFAF 74ER3_WFAF<br />

58 15 20 40 — 31 3RW4037-1BB14 74FR3_BFAF 74FR3_DFAF 74FR3_0FAF 74FR3_EFAF 74FR3_WFAF<br />

62 20 20 40 — 33 3RW4038-1BB14 74GR3_BFAF 74GR3_DFAF 74GR3_0FAF 74GR3_EFAF 74GR3_WFAF<br />

73 20 25 50 — 39 3RW4046-1BB14 74HR3_BFAF 74HR3_DFAF 74HR3_0FAF 74HR3_EFAF 74HR3_WFAF<br />

98 30 30 75 — 52 3RW4047-1BB14 74JR3_BFAF 74JR3_DFAF 74JR3_0FAF 74JR3_EFAF 74JR3_WFAF<br />

200V 6 6 6 6 6<br />

230V 2 2 2 2 2<br />

380V 3 3 3 3 3<br />

460V 4 4 4 4 4<br />

a Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor.<br />

HPs are for reference only. Enclosed ratings are at 40°C<br />

Starter selection is dependent on type of application. Ie = FLA rating of motor<br />

17-226<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: IEC


Control Products<br />

Enclosed 3RW44<br />

3RW40 Enclosed features:<br />

b Available in NEMA 1, 12, 3R, 4, and 4<br />

stainless steel<br />

b Compact size<br />

b Built-in bypass contactor<br />

b Voltage ramp up and ramp down<br />

b Current limit adjustment of 125 - 550%<br />

b Internal overload class 10, 15, or 20<br />

b Internal self protection<br />

b Fault monitoring<br />

3RW40 for Standard Applications<br />

Ordering Information<br />

Enclosed Fusible Combination (Starter with Fusible Disconnect)<br />

Enclosed devices should be ordered by<br />

the FLA of the motor.<br />

The 3RW40 is designed for normal<br />

starting applications (Class 10<br />

applications).<br />

For factory modifications see page 17-234.<br />

For complete derating and application info<br />

see page 17-261.<br />

For dimensional drawings see page 17-286.<br />

Class 74 combination starters include:<br />

b NEMA rated enclosure<br />

b Fusible disconnect<br />

b 3RW40 Sirius softstarter with built-in OL<br />

and bypass<br />

b Control circuit transformer<br />

For all technical information, please consult the 2006 Industrial Controls Catalog or contact your local sales support center.<br />

Ideal applications for 3RW40 enclosed<br />

softstarters:<br />

b Fans<br />

b Pumps<br />

b Building/construction machines<br />

b Presses<br />

b Escalators<br />

b Transport systems<br />

b Air conditioning systems<br />

b Ventilators<br />

b Assembly lines<br />

Class 74 starters are built to UL and CSA<br />

standards.<br />

Rated<br />

MAX HP a KW Class 10 Light Duty (350% * Im for 10s) b<br />

Operating OPEN Style List List List List NEMA 4/4X List<br />

Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $<br />

117 30 40 75 — 56 3RW4055-6BB34 74AS3_BFAF 74AS3_DFAF 74AS3_0FAF 74AS3_EFAF 74AS3_WFAF<br />

145 40 50 100 — 75 3RW4056-6BB34 74BS3_BFAF 74BS3_DFAF 74BS3_0FAF 74BS3_EFAF 74BS3_WFAF<br />

205 60 75 150 — 112 3RW4073-6BB34 74CS3_BFAF 74CS3_DFAF 74CS3_0FAF 74CS3_EFAF<br />

248 75 100 200 — 149 3RW4074-6BB34 74DS3_BFAF 74DS3_DFAF 74DS3_0FAF 74DS3_EFAF<br />

315 100 125 250 — 186 3RW4075-6BB34 74ES3_BFAF 74ES3_DFAF 74ES3_0FAF 74ES3_EFAF<br />

385 125 150 300 — 224 3RW4076-6BB34 74FS3_BFAF 74FS3_DFAF 74FS3_0FAF 74FS3_EFAF<br />

200V 6 6 6 6 6<br />

230V 2 2 2 2 2<br />

380V 3 3 3 3 3<br />

460V 4 4 4 4 4<br />

117 — — 75 100 — 3RW4055-6BB35 74AS35BFAF 74AS35DFAF 74AS350FAF 74AS35EFAF 74AS35WFAF<br />

145 — — 100 150 — 3RW4056-6BB35 74BS35BFAF 74BS35DFAF 74BS350FAF 74BS35EFAF 74BS35WFAF<br />

205 — — 150 200 — 3RW4073-6BB35 74CS35BFAF 74CS35DFAF 74CS350FAF 74CS35EFAF<br />

248 — — 200 250 — 3RW4074-6BB35 74DS35BFAF 74DS35DFAF 74DS350FAF 74DS35EFAF<br />

315 — — 250 300 — 3RW4075-6BB35 74ES35BFAF 74ES35DFAF 74ES350FAF 74ES35EFAF<br />

385 — — 300 400 — 3RW4076-6BB35 74FS35BFAF 74FS35DFAF 74FS350FAF 74FS35EFAF<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Enclosed Fusible Combination (Starter with Fusible Disconnect)<br />

Rated<br />

MAX HP a KW Class 20 Severe Duty (350% * Ie for 20s) b<br />

Operating OPEN Style List List List List NEMA 4/4X List<br />

Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $<br />

112 30 40 75 — 56 3RW4055-6BB34 74AS3_BFAF 74AS3_DFAF 74AS3_0FAF 74AS3_EFAF 74AS3_WFAF<br />

132 40 50 100 — 75 3RW4056-6BB34 74BS3_BFAF 74BS3_DFAF 74BS3_0FAF 74BS3_EFAF 74BS3_WFAF<br />

185 60 60 125 — 93 3RW4073-6BB34 74CS3_BFAF 74CS3_DFAF 74CS3_0FAF 74CS3_EFAF<br />

205 60 75 150 — 112 3RW4074-6BB34 74DS3_BFAF 74DS3_DFAF 74DS3_0FAF 74DS3_EFAF<br />

280 75 100 200 — 149 3RW4075-6BB34 74ES3_BFAF 74ES3_DFAF 74ES3_0FAF 74ES3_EFAF<br />

340 100 125 250 — 186 3RW4076-6BB34 74FS3_BFAF 74FS3_DFAF 74FS3_0FAF 74FS3_EFAF<br />

200V 6 6 6 6 6<br />

230V 2 2 2 2 2<br />

380V 3 3 3 3 3<br />

460V 4 4 4 4 4<br />

112 — — 75 75 — 3RW4055-6BB35 74AS35BFAF 74AS35DFAF 74AS350FAF 74AS35EFAF 74AS35WFAF<br />

132 — — 100 125 — 3RW4056-6BB35 74BS35BFAF 74BS35DFAF 74BS350FAF 74BS35EFAF 74BS35WFAF<br />

185 — — 125 150 — 3RW4073-6BB35 74CS35BFAF 74CS35DFAF 74CS350FAF 74CS35EFAF<br />

205 — — 150 200 — 3RW4074-6BB35 74DS35BFAF 74DS35DFAF 74DS350FAF 74DS35EFAF<br />

280 — — 200 250 — 3RW4075-6BB35 74ES35BFAF 74ES35DFAF 74ES350FAF 74ES35EFAF<br />

340 — — 250 300 — 3RW4076-6BB35 74FS35BFAF 74FS35DFAF 74FS350FAF 74FS35EFAF<br />

a Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor.<br />

HPs are for reference only. Enclosed ratings are at 40°C.<br />

b Starter selection is dependent on type of application. Im = FLA rating of motor.<br />

Product Category: IEC<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-227


Control Products<br />

Enclosed 3RW44<br />

3RW44 Enclosed features:<br />

b Available in NEMA 1, 12, 3R, 4, and 4<br />

stainless steel<br />

b Compact size<br />

b Built-in bypass contactor<br />

b Multiple starting/stopping techniques<br />

including torque control<br />

b Internal overload class 5, 10, 15, 20, or 30<br />

b Built-in graphical LCD keypad<br />

b Internal self protection<br />

b Fault monitoring<br />

b 3 parameter sets<br />

b Communication capable via opt. Profibus<br />

module<br />

b Programmable inputs and outputs<br />

b External keypad available<br />

Ordering Information<br />

Enclosed devices should be ordered by<br />

the FLA of the motor.<br />

The 3RW44 is designed for normal<br />

starting applications.<br />

For factory modifications see page 17-234.<br />

For complete derating and application info<br />

see page 17-261.<br />

For dimensional drawings see page 17-286.<br />

Class 73 non-combination starters include:<br />

b NEMA rated enclosure<br />

b 3RW44 Sirius softstarter with built-in OL<br />

and bypass<br />

b Control circuit transformer<br />

b Reset button<br />

Ideal applications for 3RW44 enclosed<br />

softstarters:<br />

b Fans<br />

b Pumps<br />

b Conveying systems and lifts<br />

b Hydraulics<br />

b Machine tools<br />

b Mills saws<br />

b Crushers and grinders<br />

b Mixers<br />

b HVAC systems<br />

The 3RW44 severe duty rating table should<br />

be applied for high inertia applications<br />

such rock crushers, chippers, screw<br />

compressors, ect.<br />

Class 73 starters are built to UL and CSA<br />

standards.<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

3RW44 For High Feature Applications<br />

Enclosed Non-Combination (Starter Only)<br />

Rated<br />

MAX HP a KW Class 10 Light Duty (350% * Im for 10s) b<br />

Operating OPEN Style List List List List NEMA 4/4X List<br />

Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $<br />

26 7.5 7.5 15 — 12 3RW4422-1BC34 73AT3_BFA 73AT3_DFA 73AT3_0FA 73AT3_EFA 73AT3_WFA<br />

32 10 10 20 — 15 3RW4423-1BC34 73BT3_BFA 73BT3_DFA 73BT3_0FA 73BT3_EFA 73BT3_WFA<br />

42 10 15 25 — 19 3RW4424-1BC34 73CT3_BFA 73CT3_DFA 73CT3_0FA 73CT3_EFA 73CT3_WFA<br />

51 15 15 30 — 22 3RW4425-1BC34 73DT3_BFA 73DT3_DFA 73DT3_0FA 73DT3_EFA 73DT3_WFA<br />

68 20 25 50 — 37 3RW4426-1BC34 73ET3_BFA 73ET3_DFA 73ET3_0FA 73ET3_EFA 73ET3_WFA<br />

82 25 30 60 — 45 3RW4427-1BC34 73FT3_BFA 73FT3_DFA 73FT3_0FA 73FT3_EFA 73FT3_WFA<br />

100 30 30 75 — 56 3RW4434-6BC34 73GT3_BFA 73GT3_DFA 73GT3_0FA 73GT3_EFA 73GT3_WFA<br />

117 30 40 75 — 56 3RW4435-6BC34 73HT3_BFA 73HT3_DFA 73HT3_0FA 73HT3_EFA 73HT3_WFA<br />

145 40 50 100 — 75 3RW4436-6BC34 73JT3_BFA 73JT3_DFA 73JT3_0FA 73JT3_EFA 73JT3_WFA<br />

180 60 60 125 — 93 3RW4443-6BC34 73KT3_BFA 73KT3_DFA 73KT3_0FA 73KT3_EFA 73KT3_WFA<br />

215 60 75 150 — 112 3RW4444-6BC34 73LT3_BFA 73LT3_DFA 73LT3_0FA 73LT3_EFA 73LT3_WFA<br />

280 75 100 200 — 149 3RW4445-6BC34 73MT3_BFA 73MT3_DFA 73MT3_0FA 73MT3_EFA 73MT3_WFA<br />

315 100 125 250 — 186 3RW4446-6BC34 73NT3_BFA 73NT3_DFA 73NT3_0FA 73NT3_EFA 73NT3_WFA<br />

385 125 150 300 — 224 3RW4447-6BC34 73PT3_BFA 73PT3_DFA 73PT3_0FA 73PT3_EFA 73PT3_WFA<br />

494 150 200 400 — 298 3RW4453-6BC34 73QT3_BFA 73QT3_DFA 73QT3_0FA 73QT3_EFA<br />

551 150 200 450 — 336 3RW4454-6BC34 73RT3_BFA 73RT3_DFA 73RT3_0FA 73RT3_EFA<br />

615 200 250 500 — 373 3RW4455-6BC34 73ST3_BFA 73ST3_DFA 73ST3_0FA 73ST3_EFA<br />

693 200 250 550 — 410 3RW4456-6BC34 73TT3_BFA 73TT3_DFA 73TT3_0FA 73TT3_EFA<br />

780 200 250 600 — 447 3RW4457-6BC34 73WT3_BFA 73WT3_DFA 73WT3_0FA<br />

970 350 350 800 — 597 3RW4465-6BC34 73YT3_BFA 73YT3_0FA<br />

1076 350 400 900 — 972 3RW4466-6BC34 73ZT3_BFA 73ZT3_0FA<br />

200V 6 6 6 6 6<br />

230V 2 2 2 2 2<br />

380V 3 3 3 3 3<br />

460V 4 4 4 4 4<br />

26 — — 15 20 — 3RW4422-1BC35 73AT35BFA 73AT35DFA 73AT350FA 73AT35EFA 73AT35WFA<br />

32 — — 20 25 — 3RW4423-1BC35 73BT35BFA 73BT35DFA 73BT350FA 73BT35EFA 73BT35WFA<br />

42 — — 25 30 — 3RW4424-1BC35 73CT35BFA 73CT35DFA 73CT350FA 73CT35EFA 73CT35WFA<br />

51 — — 30 40 — 3RW4425-1BC35 73DT35BFA 73DT35DFA 73DT350FA 73DT35EFA 73DT35WFA<br />

68 — — 50 50 — 3RW4426-1BC35 73ET35BFA 73ET35DFA 73ET350FA 73ET35EFA 73ET35WFA<br />

82 — — 60 75 — 3RW4427-1BC35 73FT35BFA 73FT35DFA 73FT350FA 73FT35EFA 73FT35WFA<br />

100 — — 75 75 — 3RW4434-6BC35 73GT35BFA 73GT35DFA 73GT350FA 73GT35EFA 73GT35WFA<br />

117 — — 75 100 — 3RW4435-6BC35 73HT35BFA 73HT35DFA 73HT350FA 73HT35EFA 73HT35WFA<br />

145 — — 100 125 — 3RW4436-6BC35 73JT35BFA 73JT35DFA 73JT350FA 73JT35EFA 73JT35WFA<br />

180 — — 125 150 — 3RW4443-6BC35 73KT35BFA 73KT35DFA 73KT350FA 73KT35EFA 73KT35WFA<br />

215 — — 150 200 — 3RW4444-6BC35 73LT35BFA 73LT35DFA 73LT350FA 73LT35EFA 73LT35WFA<br />

280 — — 200 250 — 3RW4445-6BC35 73MT35BFA 73MT35DFA 73MT350FA 73MT35EFA 73MT35WFA<br />

315 — — 250 300 — 3RW4446-6BC35 73NT35BFA 73NT35DFA 73NT350FA 73NT35EFA 73NT35WFA<br />

385 — — 300 400 — 3RW4447-6BC35 73PT35BFA 73PT35DFA 73PT350FA 73PT35EFA 73PT35WFA<br />

494 — — 400 500 — 3RW4453-6BC35 73QT35BFA 73QT35DFA 73QT350FA 73QT35EFA<br />

551 — — 450 600 — 3RW4454-6BC35 73RT35BFA 73RT35DFA 73RT350FA 73RT35EFA<br />

615 — — 500 700 — 3RW4455-6BC35 73ST35BFA 73ST35DFA 73ST350FA 73ST35EFA<br />

693 — — 550 750 — 3RW4456-6BC35 73TT35BFA 73TT35DFA 73TT350FA 73TT35EFA<br />

780 — — 600 850 — 3RW4457-6BC35 73WT35BFA 73WT35DFA 73WT350FA 73WT35EFA<br />

970 — — 800 1000 — 3RW4465-6BC35 73YT35BFA 73YT350FA<br />

1076 — — 900 1100 — 3RW4466-6BC35 73ZT35BFA 73ZT350FA<br />

a Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor. b Starter selection is dependent on type of application. Im = FLA rating of motor.<br />

HPs are for reference only. Enclosed ratings are at 40°C.<br />

17-228<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: IEC


Control Products<br />

Enclosed 3RW44<br />

3RW44 Enclosed features:<br />

b Available in NEMA 1, 12, 3R, 4, and 4<br />

stainless steel<br />

b Compact size<br />

b Built-in bypass contactor<br />

b Multiple starting/stopping techniques<br />

including torque control<br />

b Internal overload class 10, 15, or 20<br />

b Built-in graphical LCD keypad<br />

b Internal self protection<br />

b Fault monitoring<br />

b 3 parameter sets<br />

b Communication capable via opt. Profibus<br />

module<br />

b Programmable inputs and outputs<br />

b External keypad available<br />

3RW44 For High Feature Applications<br />

Enclosed Non-Combination (Starter Only)<br />

Ordering Information<br />

Enclosed devices should be ordered by<br />

the FLA of the motor.<br />

The 3RW44 is designed for normal<br />

starting applications.<br />

For factory modifications see page 17-234.<br />

For complete derating and application info<br />

see page 17-261.<br />

For dimensional drawings see page 17-286.<br />

Class 73 non-combination starters include:<br />

b NEMA rated enclosure<br />

b 3RW44 Sirius softstarter with built-in OL<br />

and bypass<br />

b Control circuit transformer<br />

b Line side power terminal block<br />

b Reset button<br />

Ideal applications for 3RW44 enclosed<br />

softstarters:<br />

b Fans<br />

b Pumps<br />

b Conveying systems and lifts<br />

b Hydraulics<br />

b Machine tools<br />

b Mills saws<br />

b Crushers and grinders<br />

b Mixers<br />

b HVAC systems<br />

The 3RW44 severe duty rating table should<br />

be applied for high inertia applications<br />

such rock crushers, chippers, screw<br />

compressors, ect.<br />

Class 73 starters are built to UL and CSA<br />

standards.<br />

Rated<br />

MAX HP a KW Class 20 Severe Duty (350% * Im for 20s) b<br />

Operating OPEN Style List List List List NEMA 4/4X List<br />

Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $<br />

26 7.5 7.5 15 — 12 3RW4422-1BC34 73AT3_BFA 73AT3_DFA 73AT3_0FA 73AT3_EFA 73AT3_WFA<br />

32 10 10 20 — 15 3RW4423-1BC34 73BT3_BFA 73BT3_DFA 73BT3_0FA 73BT3_EFA 73BT3_WFA<br />

42 10 15 25 — 19 3RW4424-1BC34 73CT3_BFA 73CT3_DFA 73CT3_0FA 73CT3_EFA 73CT3_WFA<br />

51 15 15 30 — 22 3RW4425-1BC34 73DT3_BFA 73DT3_DFA 73DT3_0FA 73DT3_EFA 73DT3_WFA<br />

68 20 25 50 — 37 3RW4426-1BC34 73ET3_BFA 73ET3_DFA 73ET3_0FA 73ET3_EFA 73ET3_WFA<br />

82 25 30 60 — 45 3RW4427-1BC34 73FT3_BFA 73FT3_DFA 73FT3_0FA 73FT3_EFA 73FT3_WFA<br />

97 30 30 60 — 45 3RW4434-6BC34 73GT3_BFA 73GT3_DFA 73GT3_0FA 73GT3_EFA 73GT3_WFA<br />

113 30 40 75 — 56 3RW4435-6BC34 73HT3_BFA 73HT3_DFA 73HT3_0FA 73HT3_EFA 73HT3_WFA<br />

134 40 50 75 — 56 3RW4436-6BC34 73JT3_BFA 73JT3_DFA 73JT3_0FA 73JT3_EFA 73JT3_WFA<br />

175 50 60 100 — 75 3RW4443-6BC34 73KT3_BFA 73KT3_DFA 73KT3_0FA 73KT3_EFA 73KT3_WFA<br />

195 60 75 125 — 93 3RW4444-6BC34 73LT3_BFA 73LT3_DFA 73LT3_0FA 73LT3_EFA 73LT3_WFA<br />

243 75 75 150 — 112 3RW4445-6BC34 73MT3_BFA 73MT3_DFA 73MT3_0FA 73MT3_EFA 73MT3_WFA<br />

263 75 100 200 — 149 3RW4446-6BC34 73NT3_BFA 73NT3_DFA 73NT3_0FA 73NT3_EFA 73NT3_WFA<br />

326 100 125 250 — 186 3RW4447-6BC34 73PT3_BFA 73PT3_DFA 73PT3_0FA 73PT3_EFA 73PT3_WFA<br />

494 150 150 400 — 224 3RW4453-6BC34 73QT3_BFA 73QT3_DFA 73QT3_0FA 73QT3_EFA<br />

551 150 200 450 — 298 3RW4454-6BC34 73RT3_BFA 73RT3_DFA 73RT3_0FA 73RT3_EFA<br />

615 200 200 500 — 336 3RW4455-6BC34 73ST3_BFA 73ST3_DFA 73ST3_0FA 73ST3_EFA<br />

634 200 250 500 — 373 3RW4456-6BC34 73TT3_BFA 73TT3_DFA 73TT3_0FA 73TT3_EFA<br />

650 200 250 550 — 410 3RW4457-6BC34 73WT3_BFA 73WT3_DFA 73WT3_0FA 73WT3_EFA<br />

880 300 350 700 — 522 3RW4465-6BC34 73YT3_BFA 73YT3_0FA<br />

940 300 350 750 — 559 3RW4466-6BC34 73ZT3_BFA 73ZT3_0FA<br />

200V 6 6 6 6 6<br />

230V 2 2 2 2 2<br />

380V 3 3 3 3 3<br />

460V 4 4 4 4 4<br />

26 — — 15 20 — 3RW4422-1BC35 73AT35BFA 73AT35DFA 73AT350FA 73AT35EFA 73AT35WFA<br />

32 — — 20 25 — 3RW4423-1BC35 73BT35BFA 73BT35DFA 73BT350FA 73BT35EFA 73BT35WFA<br />

42 — — 25 30 — 3RW4424-1BC35 73CT35BFA 73CT35DFA 73CT350FA 73CT35EFA 73CT35WFA<br />

51 — — 30 40 — 3RW4425-1BC35 73DT35BFA 73DT35DFA 73DT350FA 73DT35EFA 73DT35WFA<br />

68 — — 50 50 — 3RW4426-1BC35 73ET35BFA 73ET35DFA 73ET350FA 73ET35EFA 73ET35WFA<br />

82 — — 60 75 — 3RW4427-1BC35 73FT35BFA 73FT35DFA 73FT350FA 73FT35EFA 73FT35WFA<br />

97 — — 60 75 — 3RW4434-6BC35 73GT35BFA 73GT35DFA 73GT350FA 73GT35EFA 73GT35WFA<br />

113 — — 75 100 — 3RW4435-6BC35 73HT35BFA 73HT35DFA 73HT350FA 73HT35EFA 73HT35WFA<br />

134 — — 75 125 — 3RW4436-6BC35 73JT35BFA 73JT35DFA 73JT350FA 73JT35EFA 73JT35WFA<br />

175 — — 100 150 — 3RW4443-6BC35 73KT35BFA 73KT35DFA 73KT350FA 73KT35EFA 73KT35WFA<br />

195 — — 125 200 — 3RW4444-6BC35 73LT35BFA 73LT35DFA 73LT350FA 73LT35EFA 73LT35WFA<br />

243 — — 150 200 — 3RW4445-6BC35 73MT35BFA 73MT35DFA 73MT350FA 73MT35EFA 73MT35WFA<br />

263 — — 200 250 — 3RW4446-6BC35 73NT35BFA 73NT35DFA 73NT350FA 73NT35EFA 73NT35WFA<br />

326 — — 250 300 — 3RW4447-6BC35 73PT35BFA 73PT35DFA 73PT350FA 73PT35EFA 73PT35WFA<br />

494 — — 400 500 — 3RW4453-6BC35 73QT35BFA 73QT35DFA 73QT350FA 73QT35EFA<br />

551 — — 450 550 — 3RW4454-6BC35 73RT35BFA 73RT35DFA 73RT350FA 73RT35EFA<br />

615 — — 500 600 — 3RW4455-6BC35 73ST35BFA 73ST35DFA 73ST350FA 73ST35EFA<br />

693 — — 500 650 — 3RW4456-6BC35 73TT35BFA 73TT35DFA 73TT350FA 73TT35EFA<br />

780 — — 550 700 — 3RW4457-6BC35 73WT35BFA 73WT35DFA 73WT350FA 73WT35EFA<br />

880 — — 700 850 — 3RW4465-6BC35 73YT35BFA 73YT350FA<br />

940 — — 750 900 — 3RW4466-6BC35 73ZT35BFA 73ZT350FA<br />

a Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor.<br />

HPs are for reference only. Enclosed ratings are at 40°C.<br />

b Starter selection is dependent on type of application. Im = FLA rating of motor.<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Product Category: IEC<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-229


Control Products<br />

Enclosed 3RW44<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

3RW44 Enclosed features:<br />

b Available in NEMA 1, 12, 3R, 4, and 4<br />

stainless steel<br />

b Compact size<br />

b Built-in bypass contactor<br />

b Multiple starting/stopping techniques<br />

including torque control<br />

b Internal overload class 5, 10, 15, 20, or 30<br />

b Built-in graphical LCD keypad<br />

b Internal self protection<br />

b Fault monitoring<br />

b 3 parameter sets<br />

b Communication capable via opt. Profibus<br />

module<br />

b Programmable inputs and outputs<br />

b External keypad available<br />

3RW44 For High Feature Applications<br />

Enclosed Combination with Circuit Breaker Disconnect<br />

Ordering Information<br />

Enclosed devices should be ordered by<br />

the FLA of the motor.<br />

The 3RW44 is designed for normal<br />

starting applications.<br />

For factory modifications see page 17-234.<br />

For complete derating and application info<br />

see page 17-261.<br />

For dimensional drawings see page 17-286.<br />

For stocked versions see page 7/89.<br />

Class 74 non-combination starters include:<br />

b NEMA rated enclosure<br />

b 3RW44 Sirius softstarter with built-in OL<br />

and bypass<br />

b Circuit breaker with disconnect<br />

b Control circuit transformer<br />

b Reset button<br />

Ideal applications for 3RW44 enclosed<br />

softstarters:<br />

b Fans<br />

b Pumps<br />

b Conveying systems and lifts<br />

b Hydraulics<br />

b Machine tools<br />

b Mills saws<br />

b Crushers and grinders<br />

b Mixers<br />

b HVAC systems<br />

The 3RW44 severe duty rating table should<br />

be applied for high inertia applications<br />

such rock crushers, chippers, screw<br />

compressors, ect.<br />

Class 74 starters are built to UL and CSA<br />

standards.<br />

Rated<br />

MAX HP a KW Class 10 Light Duty (350% * Im for 10s) b<br />

Operating OPEN Style List List List List NEMA 4/4X List<br />

Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $<br />

26 7.5 7.5 15 — 12 3RW4422-1BC34 74AT3_BFAP 74AT3_DFAP 74AT3_0FAP 74AT3_EFAP 74AT3_WFAP<br />

32 10 10 20 — 15 3RW4423-1BC34 74BT3_BFAP 74BT3_DFAP 74BT3_0FAP 74BT3_EFAP 74BT3_WFAP<br />

42 10 15 25 — 19 3RW4424-1BC34 74CT3_BFAP 74CT3_DFAP 74CT3_0FAP 74CT3_EFAP 74CT3_WFAP<br />

51 15 15 30 — 22 3RW4425-1BC34 74DT3_BFAP 74DT3_DFAP 74DT3_0FAP 74DT3_EFAP 74DT3_WFAP<br />

68 20 25 50 — 37 3RW4426-1BC34 74ET3_BFAP 74ET3_DFAP 74ET3_0FAP 74ET3_EFAP 74ET3_WFAP<br />

82 25 30 60 — 45 3RW4427-1BC34 74FT3_BFAP 74FT3_DFAP 74FT3_0FAP 74FT3_EFAP 74FT3_WFAP<br />

100 30 30 75 — 56 3RW4434-6BC34 74GT3_BFAP 74GT3_DFAP 74GT3_0FAP 74GT3_EFAP 74GT3_WFAP<br />

117 30 40 75 — 56 3RW4435-6BC34 74HT3_BFAP 74HT3_DFAP 74HT3_0FAP 74HT3_EFAP 74HT3_WFAP<br />

145 40 50 100 — 75 3RW4436-6BC34 74JT3_BFAP 74JT3_DFAP 74JT3_0FAP 74JT3_EFAP 74JT3_WFAP<br />

180 60 60 125 — 93 3RW4443-6BC34 74KT3_BFAP 74KT3_DFAP 74KT3_0FAP 74KT3_EFAP<br />

215 60 75 150 — 112 3RW4444-6BC34 74LT3_BFAP 74LT3_DFAP 74LT3_0FAP 74LT3_EFAP<br />

280 75 100 200 — 149 3RW4445-6BC34 74MT3_BFAP 74MT3_DFAP 74MT3_0FAP 74MT3_EFAP<br />

315 100 125 250 — 186 3RW4446-6BC34 74NT3_BFAP 74NT3_DFAP 74NT3_0FAP 74NT3_EFAP<br />

385 125 150 300 — 224 3RW4447-6BC34 74PT3_BFAP 74PT3_DFAP 74PT3_0FAP 74PT3_EFAP<br />

494 150 200 400 — 298 3RW4453-6BC34 74QT3_BFAT 74QT3_DFAT 74QT3_0FAT 74QT3_EFAT<br />

551 150 200 450 — 336 3RW4454-6BC34 74RT3_BFAT 74RT3_DFAT 74RT3_0FAT 74RT3_EFAT<br />

615 200 250 500 — 373 3RW4455-6BC34 74ST3_BFAT 74ST3_DFAT 74ST3_0FAT 74ST3_EFAT<br />

693 200 250 550 — 410 3RW4456-6BC34 74TT3_BFAT 74TT3_DFAT 74TT3_0FAT 74TT3_EFAT<br />

780 200 250 600 — 447 3RW4457-6BC34 74WT3_BFAT 74WT3_DFAT 74WT3_0FAT 74WT3_EFAT<br />

970 350 350 800 — 597 3RW4465-6BC34 74YT3_BFAT 74YT3_0FAT<br />

1076 350 400 900 — 672 3RW4466-6BC34 74ZT3_BFAT 74ZT3_0FAT<br />

200V 6 6 6 6 6<br />

230V 2 2 2 2 2<br />

380V 3 3 3 3 3<br />

460V 4 4 4 4 4<br />

26 — — 15 20 — 3RW4422-1BC35 74AT35BFAP 74AT35DFAP 74AT350FAP 74AT35EFAP 74AT35WFAP<br />

32 — — 20 25 — 3RW4423-1BC35 74BT35BFAP 74BT35DFAP 74BT350FAP 74BT35EFAP 74BT35WFAP<br />

42 — — 25 30 — 3RW4424-1BC35 74CT35BFAP 74CT35DFAP 74CT350FAP 74CT35EFAP 74CT35WFAP<br />

51 — — 30 40 — 3RW4425-1BC35 74DT35BFAP 74DT35DFAP 74DT350FAP 74DT35EFAP 74DT35WFAP<br />

68 — — 50 50 — 3RW4426-1BC35 74ET35BFAP 74ET35DFAP 74ET350FAP 74ET35EFAP 74ET35WFAP<br />

82 — — 60 75 — 3RW4427-1BC35 74FT35BFAP 74FT35DFAP 74FT350FAP 74FT35EFAP 74FT35WFAP<br />

100 — — 75 75 — 3RW4434-6BC35 74GT35BFAP 74GT35DFAP 74GT350FAP 74GT35EFAP 74GT35WFAP<br />

117 — — 75 100 — 3RW4435-6BC35 74HT35BFAP 74HT35DFAP 74HT350FAP 74HT35EFAP 74HT35WFAP<br />

145 — — 100 125 — 3RW4436-6BC35 74JT35BFAP 74JT35DFAP 74JT350FAP 74JT35EFAP 74JT35WFAP<br />

180 — — 125 150 — 3RW4443-6BC35 74KT35BFAP 74KT35DFAP 74KT350FAP 74KT35EFAP<br />

215 — — 150 200 — 3RW4444-6BC35 74LT35BFAP 74LT35DFAP 74LT350FAP 74LT35EFAP<br />

280 — — 200 250 — 3RW4445-6BC35 74MT35BFAP 74MT35DFAP 74MT350FAP 74MT35EFAP<br />

315 — — 250 300 — 3RW4446-6BC35 74NT35BFAP 74NT35DFAP 74NT350FAP 74NT35EFAP<br />

385 — — 300 400 — 3RW4447-6BC35 74PT35BFAP 74PT35DFAP 74PT350FAP 74PT35EFAP<br />

494 — — 400 500 — 3RW4453-6BC35 74QT35BFAT 74QT35DFAT 74QT350FAT 74QT35EFAT<br />

551 — — 450 600 — 3RW4454-6BC35 74RT35BFAT 74RT35DFAT 74RT350FAT 74RT35EFAT<br />

615 — — 500 700 — 3RW4455-6BC35 74ST35BFAT 74ST35DFAT 74ST350FAT 74ST35EFAT<br />

693 — — 550 750 — 3RW4456-6BC35 74TT35BFAT 74TT35DFAT 74TT350FAT 74TT35EFAT<br />

780 — — 600 850 — 3RW4457-6BC35 74WT35BFAT 74WT35DFAT 74WT350FAT 74WT35EFAT<br />

970 — — 800 1000 — 3RW4465-6BC35 74YT35BFAT 74YT350FAT<br />

1076 — — 900 1100 — 3RW4466-6BC35 74ZT35BFAT 74ZT350FAT<br />

a Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor.<br />

HPs are for reference only. Enclosed ratings are at 40°C.<br />

b Starter selection is dependent on type of application. Im = FLA rating of motor.<br />

17-230<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: IEC


Control Products<br />

Enclosed 3RW44<br />

3RW44 Enclosed features:<br />

b Available in NEMA 1, 12, 3R, 4, and 4<br />

stainless steel<br />

b Compact size<br />

b Built-in bypass contactor<br />

b Multiple starting/stopping techniques<br />

including torque control<br />

b Internal overload class 5, 10, 15, 20, or 30<br />

b Built-in graphical LCD keypad<br />

b Internal self protection<br />

b Fault monitoring<br />

b 3 parameter sets<br />

b Communication capable via opt. Profibus<br />

module<br />

b Programmable inputs and outputs<br />

b External keypad available<br />

3RW44 For High Feature Applications<br />

Enclosed Combination with Circuit Breaker Disconnect<br />

Ordering Information<br />

Enclosed devices should be ordered by<br />

the FLA of the motor.<br />

The 3RW44 is designed for normal<br />

starting applications.<br />

For factory modifications see page 17-234.<br />

For complete derating and application info<br />

see page 17-261.<br />

For dimensional drawings see page 17-286.<br />

For stocked versions see page 7/89.<br />

Class 74 non-combination starters include:<br />

b NEMA rated enclosure<br />

b 3RW44 Sirius softstarter with built-in OL<br />

and bypass<br />

b Circuit breaker with disconnect<br />

b Control circuit transformer<br />

b Reset button<br />

Ideal applications for 3RW44 enclosed<br />

softstarters:<br />

b Fans<br />

b Pumps<br />

b Conveying systems and lifts<br />

b Hydraulics<br />

b Machine tools<br />

b Mills saws<br />

b Crushers and grinders<br />

b Mixers<br />

b HVAC systems<br />

The 3RW44 severe duty rating table should<br />

be applied for high inertia applications<br />

such rock crushers, chippers, screw<br />

compressors, ect.<br />

Class 74 starters are built to UL and CSA<br />

standards.<br />

Rated<br />

MAX HP a KW Class 20 Severe Duty (350% * Im for 20s) b<br />

Operating OPEN Style List List List List NEMA 4/4X List<br />

Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $<br />

26 7.5 7.5 15 — 12 3RW4422-1BC34 74AT3_BFAP 74AT3_DFAP 74AT3_0FAP 74AT3_EFAP 74AT3_WFAP<br />

32 10 10 20 — 15 3RW4423-1BC34 74BT3_BFAP 74BT3_DFAP 74BT3_0FAP 74BT3_EFAP 74BT3_WFAP<br />

42 10 15 25 — 19 3RW4424-1BC34 74CT3_BFAP 74CT3_DFAP 74CT3_0FAP 74CT3_EFAP 74CT3_WFAP<br />

51 15 15 30 — 22 3RW4425-1BC34 74DT3_BFAP 74DT3_DFAP 74DT3_0FAP 74DT3_EFAP 74DT3_WFAP<br />

68 20 25 50 — 37 3RW4426-1BC34 74ET3_BFAP 74ET3_DFAP 74ET3_0FAP 74ET3_EFAP 74ET3_WFAP<br />

82 25 30 60 — 45 3RW4427-1BC34 74FT3_BFAP 74FT3_DFAP 74FT3_0FAP 74FT3_EFAP 74FT3_WFAP<br />

97 30 30 60 — 45 3RW4434-6BC34 74GT3_BFAP 74GT3_DFAP 74GT3_0FAP 74GT3_EFAP 74GT3_WFAP<br />

113 30 40 75 — 56 3RW4435-6BC34 74HT3_BFAP 74HT3_DFAP 74HT3_0FAP 74HT3_EFAP 74HT3_WFAP<br />

134 40 50 75 — 56 3RW4436-6BC34 74JT3_BFAP 74JT3_DFAP 74JT3_0FAP 74JT3_EFAP 74JT3_WFAP<br />

175 50 60 100 — 75 3RW4443-6BC34 74KT3_BFAP 74KT3_DFAP 74KT3_0FAP 74KT3_EFAP<br />

195 60 75 125 — 93 3RW4444-6BC34 74LT3_BFAP 74LT3_DFAP 74LT3_0FAP 74LT3_EFAP<br />

243 75 75 150 — 112 3RW4445-6BC34 74MT3_BFAP 74MT3_DFAP 74MT3_0FAP 74MT3_EFAP<br />

263 75 100 200 — 149 3RW4446-6BC34 74NT3_BFAP 74NT3_DFAP 74NT3_0FAP 74NT3_EFAP<br />

326 100 125 250 — 186 3RW4447-6BC34 74PT3_BFAP 74PT3_DFAP 74PT3_0FAP 74PT3_EFAP<br />

494 150 150 400 — 224 3RW4453-6BC34 74QT3_BFAT 74QT3_DFAT 74QT3_0FAT 74QT3_EFAT<br />

551 150 200 450 — 298 3RW4454-6BC34 74RT3_BFAT 74RT3_DFAT 74RT3_0FAT 74RT3_EFAT<br />

615 200 200 500 — 336 3RW4455-6BC34 74ST3_BFAT 74ST3_DFAT 74ST3_0FAT 74ST3_EFAT<br />

634 200 250 500 — 373 3RW4456-6BC34 74TT3_BFAT 74TT3_DFAT 74TT3_0FAT 74TT3_EFAT<br />

650 200 250 550 — 410 3RW4457-6BC34 74WT3_BFAT 74WT3_DFAT 74WT3_0FAT 74WT3_EFAT<br />

880 300 350 700 — 522 3RW4465-6BC34 74YT3_BFAT 74YT3_0FAT<br />

940 300 350 750 — 559 3RW4466-6BC34 74ZT3_BFAT 74ZT3_0FAT<br />

200V 6 6 6 6 6<br />

230V 2 2 2 2 2<br />

380V 3 3 3 3 3<br />

460V 4 4 4 4 4<br />

26 — — 15 20 — 3RW4422-1BC35 74AT35BFAP 74AT35DFAP 74AT350FAP 74AT35EFAP 74AT35WFAP<br />

32 — — 20 25 — 3RW4423-1BC35 74BT35BFAP 74BT35DFAP 74BT350FAP 74BT35EFAP 74BT35WFAP<br />

42 — — 25 30 — 3RW4424-1BC35 74CT35BFAP 74CT35DFAP 74CT350FAP 74CT35EFAP 74CT35WFAP<br />

51 — — 30 40 — 3RW4425-1BC35 74DT35BFAP 74DT35DFAP 74DT350FAP 74DT35EFAP 74DT35WFAP<br />

68 — — 50 50 — 3RW4426-1BC35 74ET35BFAP 74ET35DFAP 74ET350FAP 74ET35EFAP 74ET35WFAP<br />

82 — — 60 75 — 3RW4427-1BC35 74FT35BFAP 74FT35DFAP 74FT350FAP 74FT35EFAP 74FT35WFAP<br />

97 — — 60 75 — 3RW4434-6BC35 74GT35BFAP 74GT35DFAP 74GT350FAP 74GT35EFAP 74GT35WFAP<br />

113 — — 75 100 — 3RW4435-6BC35 74HT35BFAP 74HT35DFAP 74HT350FAP 74HT35EFAP 74HT35WFAP<br />

134 — — 75 125 — 3RW4436-6BC35 74JT35BFAP 74JT35DFAP 74JT350FAP 74JT35EFAP 74JT35WFAP<br />

175 — — 100 150 — 3RW4443-6BC35 74KT35BFAP 74KT35DFAP 74KT350FAP 74KT35EFAP<br />

195 — — 125 200 — 3RW4444-6BC35 74LT35BFAP 74LT35DFAP 74LT350FAP 74LT35EFAP<br />

243 — — 150 200 — 3RW4445-6BC35 74MT35BFAP 74MT35DFAP 74MT350FAP 74MT35EFAP<br />

263 — — 200 250 — 3RW4446-6BC35 74NT35BFAP 74NT35DFAP 74NT350FAP 74NT35EFAP<br />

326 — — 250 300 — 3RW4447-6BC35 74PT35BFAP 74PT35DFAP 74PT350FAP 74PT35EFAP<br />

494 — — 400 500 — 3RW4453-6BC35 74QT35BFAT 74QT35DFAT 74QT350FAT 74QT35EFAT<br />

551 — — 450 550 — 3RW4454-6BC35 74RT35BFAT 74RT35DFAT 74RT350FAT 74RT35EFAT<br />

615 — — 500 600 — 3RW4455-6BC35 74ST35BFAT 74ST35DFAT 74ST350FAT 74ST35EFAT<br />

693 — — 500 650 — 3RW4456-6BC35 74TT35BFAT 74TT35DFAT 74TT350FAT 74TT35EFAT<br />

780 — — 550 700 — 3RW4457-6BC35 74WT35BFAT 74WT35DFAT 74WT350FAT 74WT35EFAT<br />

880 — — 700 850 — 3RW4465-6BC35 74YT35BFAT 74YT350FAT<br />

940 — — 750 900 — 3RW4466-6BC35 74ZT35BFAT 74ZT350FAT<br />

a Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor.<br />

HPs are for reference only. Enclosed ratings are at 40°C.<br />

b Starter selection is dependent on type of application. Im = FLA rating of motor.<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Product Category: IEC<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-231


Control Products<br />

Enclosed 3RW44<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Enclosed Combination with Fusible Disconnect<br />

Ordering Information<br />

Enclosed devices should be ordered by<br />

the FLA of the motor.<br />

The 3RW44 is designed for normal<br />

starting applications.<br />

For factory modifications see page 17-234.<br />

For complete derating and application info<br />

see page 17-261.<br />

For dimensional drawings see page 17-286.<br />

Class 74 non-combination starters include:<br />

b NEMA rated enclosure<br />

b 3RW44 Sirius softstarter with built-in OL<br />

and bypass<br />

b Fusible disconnect<br />

b Control circuit transformer<br />

b Reset button<br />

3RW44 Enclosed features:<br />

b Available in NEMA 1, 12, 3R, 4, and 4<br />

stainless steel<br />

b Compact size<br />

b Built-in bypass contactor<br />

b Multiple starting/stopping techniques<br />

including torque control<br />

b Internal overload class 5, 10, 15, 20, or 30<br />

b Built-in graphical LCD keypad<br />

b Internal self protection<br />

b Fault monitoring<br />

b 3 parameter sets<br />

b Communication capable via opt. Profibus<br />

module<br />

b Programmable inputs and outputs<br />

b External keypad available<br />

For all technical information, please consult the 2006 Industrial Controls Catalog or contact your local sales support center.<br />

3RW44 For High Feature Applications<br />

Ideal applications for 3RW44 enclosed<br />

softstarters:<br />

b Fans<br />

b Pumps<br />

b Conveying systems and lifts<br />

b Hydraulics<br />

b Machine tools<br />

b Mills saws<br />

b Crushers and grinders<br />

b Mixers<br />

b HVAC systems<br />

The 3RW44 severe duty rating table should<br />

be applied for high inertia applications<br />

such rock crushers, chippers, screw<br />

compressors, ect.<br />

Class 74 starters are built to UL and CSA<br />

standards.<br />

Rated<br />

MAX HP a KW Class 10 Light Duty b (350% * Im for 10s)<br />

Operating OPEN Style List List List List NEMA 4/4X List<br />

Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $<br />

26 7.5 7.5 15 — 12 3RW4422-1BC34 74AT3_BFAF 74AT3_DFAF 74AT3_0FAF 74AT3_EFAF 74AT3_WFAF<br />

32 10 10 20 — 15 3RW4423-1BC34 74BT3_BFAF 74BT3_DFAF 74BT3_0FAF 74BT3_EFAF 74BT3_WFAF<br />

42 10 15 25 — 19 3RW4424-1BC34 74CT3_BFAF 74CT3_DFAF 74CT3_0FAF 74CT3_EFAF 74CT3_WFAF<br />

51 15 15 30 — 22 3RW4425-1BC34 74DT3_BFAF 74DT3_DFAF 74DT3_0FAF 74DT3_EFAF 74DT3_WFAF<br />

68 20 25 50 — 37 3RW4426-1BC34 74ET3_BFAF 74ET3_DFAF 74ET3_0FAF 74ET3_EFAF 74ET3_WFAF<br />

82 25 30 60 — 45 3RW4427-1BC34 74FT3_BFAF 74FT3_DFAF 74FT3_0FAF 74FT3_EFAF 74FT3_WFAF<br />

100 30 30 75 — 56 3RW4434-6BC34 74GT3_BFAF 74GT3_DFAF 74GT3_0FAF 74GT3_EFAF 74GT3_WFAF<br />

117 30 40 75 — 56 3RW4435-6BC34 74HT3_BFAF 74HT3_DFAF 74HT3_0FAF 74HT3_EFAF 74HT3_WFAF<br />

145 40 50 100 — 75 3RW4436-6BC34 74JT3_BFAF 74JT3_DFAF 74JT3_0FAF 74JT3_EFAF 74JT3_WFAF<br />

180 60 60 125 — 93 3RW4443-6BC34 74KT3_BFAF 74KT3_DFAF 74KT3_0FAF 74KT3_EFAF<br />

215 60 75 150 — 112 3RW4444-6BC34 74LT3_BFAF 74LT3_DFAF 74LT3_0FAF 74LT3_EFAF<br />

280 75 100 200 — 149 3RW4445-6BC34 74MT3_BFAF 74MT3_DFAF 74MT3_0FAF 74MT3_EFAF<br />

315 100 125 250 — 186 3RW4446-6BC34 74NT3_BFAF 74NT3_DFAF 74NT3_0FAF 74NT3_EFAF<br />

385 125 150 300 — 224 3RW4447-6BC34 74PT3_BFAF 74PT3_DFAF 74PT3_0FAF 74PT3_EFAF<br />

494 150 200 400 — 298 3RW4453-6BC34 74QT3_BFAF 74QT3_0FAF<br />

551 150 200 450 — 336 3RW4454-6BC34 74RT3_BFAF 74RT3_0FAF<br />

615 200 250 500 — 373 3RW4455-6BC34 74ST3_BFAF 74ST3_0FAF<br />

693 200 250 550 — 3RW4456-6BC34 74TT3_BFAF 74TT3_0FAF<br />

780 200 250 600 — 447 3RW4457-6BC34 74WT3_BFAF 74WT3_0FAF<br />

200V 6 6 6 6 6<br />

230V 2 2 2 2 2<br />

380V 3 3 3 3 3<br />

460V 4 4 4 4 4<br />

26 — — 15 20 — 3RW4422-1BC35 74AT35BFAF 74AT35DFAF 74AT350FAF 74AT35EFAF 74AT35WFAF<br />

32 — — 20 25 — 3RW4423-1BC35 74BT35BFAF 74BT35DFAF 74BT350FAF 74BT35EFAF 74BT35WFAF<br />

42 — — 25 30 — 3RW4424-1BC35 74CT35BFAF 74CT35DFAF 74CT350FAF 74CT35EFAF 74CT35WFAF<br />

51 — — 30 40 — 3RW4425-1BC35 74DT35BFAF 74DT35DFAF 74DT350FAF 74DT35EFAF 74DT35WFAF<br />

68 — — 50 50 — 3RW4426-1BC35 74ET35BFAF 74ET35DFAF 74ET350FAF 74ET35EFAF 74ET35WFAF<br />

82 — — 60 75 — 3RW4427-1BC35 74FT35BFAF 74FT35DFAF 74FT350FAF 74FT35EFAF 74FT35WFAF<br />

100 — — 75 75 — 3RW4434-6BC35 74GT35BFAF 74GT35DFAF 74GT350FAF 74GT35EFAF 74GT35WFAF<br />

117 — — 75 100 — 3RW4435-6BC35 74HT35BFAF 74HT35DFAF 74HT350FAF 74HT35EFAF 74HT35WFAF<br />

145 — — 100 125 — 3RW4436-6BC35 74JT35BFAF 74JT35DFAF 74JT350FAF 74JT35EFAF 74JT35WFAF<br />

180 — — 125 150 — 3RW4443-6BC35 74KT35BFAF 74KT35DFAF 74KT350FAF 74KT35EFAF<br />

215 — — 150 200 — 3RW4444-6BC35 74LT35BFAF 74LT35DFAF 74LT350FAF 74LT35EFAF<br />

280 — — 200 250 — 3RW4445-6BC35 74MT35BFAF 74MT35DFAF 74MT350FAF 74MT35EFAF<br />

315 — — 250 300 — 3RW4446-6BC35 74NT35BFAF 74NT35DFAF 74NT350FAF 74NT35EFAF<br />

385 — — 300 400 — 3RW4447-6BC35 74PT35BFAF 74PT35DFAF 74PT350FAF 74PT35EFAF<br />

494 — — 400 500 — 3RW4453-6BC35 74QT35BFAF 74QT350FAF<br />

551 — — 450 600 — 3RW4454-6BC35 74RT35BFAF 74RT350FAF<br />

615 — — 500 700 — 3RW4455-6BC35 74ST35BFAF 74ST350FAF<br />

693 — — 550 750 — 3RW4456-6BC35 74TT35BFAF 74TT350FAF<br />

780 — — 600 850 — 3RW4457-6BC35 74WT35BFAF 74WT350FAF<br />

a Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor. b Starter selection is dependent on type of application. Im = FLA rating of motor.<br />

HPs are for reference only. Enclosed ratings are at 40°C.<br />

17-232<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: IEC


Control Products<br />

Enclosed 3RW44<br />

Enclosed Combination with Fusible Disconnect<br />

Ordering Information<br />

Enclosed devices should be ordered by<br />

the FLA of the motor.<br />

The 3RW44 is designed for normal<br />

starting applications.<br />

For factory modifications see page 17-234.<br />

For complete derating and application info<br />

see page 17-261.<br />

For dimensional drawings see page 17-286.<br />

Class 74 non-combination starters include:<br />

b NEMA rated enclosure<br />

b 3RW44 Sirius softstarter with built-in OL<br />

and bypass<br />

b Fusible disconnect<br />

b Control circuit transformer<br />

b Reset button<br />

3RW44 Enclosed features:<br />

b Available in NEMA 1, 12, 3R, 4, and 4<br />

stainless steel<br />

b Compact size<br />

b Built-in bypass contactor<br />

b Multiple starting/stopping techniques<br />

including torque control<br />

b Internal overload class 5, 10, 15, 20, or 30<br />

b Built-in graphical LCD keypad<br />

b Internal self protection<br />

b Fault monitoring<br />

b 3 parameter sets<br />

b Communication capable via opt. Profibus<br />

module<br />

b Programmable inputs and outputs<br />

b External keypad available<br />

For all technical information, please consult the 2006 Industrial Controls Catalog or contact your local sales support center.<br />

3RW44 For High Feature Applications<br />

Ideal applications for 3RW44 enclosed<br />

softstarters:<br />

b Fans<br />

b Pumps<br />

b Conveying systems and lifts<br />

b Hydraulics<br />

b Machine tools<br />

b Mills saws<br />

b Crushers and grinders<br />

b Mixers<br />

b HVAC systems<br />

The 3RW44 severe duty rating table should<br />

be applied for high inertia applications<br />

such rock crushers, chippers, screw<br />

compressors, ect.<br />

Class 74 starters are built to UL and CSA<br />

standards.<br />

Rated<br />

MAX HP a KW Class 20 Severe Duty (350% * Im for 20s) b<br />

Operating OPEN Style List List List List NEMA 4/4X List<br />

Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $<br />

26 7.5 7.5 15 — 12 3RW4422-1BC34 74AT3_BFAF 74AT3_DFAF 74AT3_0FAF 74AT3_EFAF 74AT3_WFAF<br />

32 10 10 20 — 15 3RW4423-1BC34 74BT3_BFAF 74BT3_DFAF 74BT3_0FAF 74BT3_EFAF 74BT3_WFAF<br />

42 10 15 25 — 19 3RW4424-1BC34 74CT3_BFAF 74CT3_DFAF 74CT3_0FAF 74CT3_EFAF 74CT3_WFAF<br />

51 15 15 30 — 22 3RW4425-1BC34 74DT3_BFAF 74DT3_DFAF 74DT3_0FAF 74DT3_EFAF 74DT3_WFAF<br />

68 20 25 50 — 37 3RW4426-1BC34 74ET3_BFAF 74ET3_DFAF 74ET3_0FAF 74ET3_EFAF 74ET3_WFAF<br />

82 25 30 60 — 45 3RW4427-1BC34 74FT3_BFAF 74FT3_DFAF 74FT3_0FAF 74FT3_EFAF 74FT3_WFAF<br />

97 30 30 60 — 45 3RW4434-6BC34 74GT3_BFAF 74GT3_DFAF 74GT3_0FAF 74GT3_EFAF 74GT3_WFAF<br />

113 30 40 75 — 56 3RW4435-6BC34 74HT3_BFAF 74HT3_DFAF 74HT3_0FAF 74HT3_EFAF 74HT3_WFAF<br />

134 40 50 75 — 56 3RW4436-6BC34 74JT3_BFAF 74JT3_DFAF 74JT3_0FAF 74JT3_EFAF 74JT3_WFAF<br />

175 50 60 100 — 75 3RW4443-6BC34 74KT3_BFAF 74KT3_DFAF 74KT3_0FAF 74KT3_EFAF<br />

195 60 75 125 — 93 3RW4444-6BC34 74LT3_BFAF 74LT3_DFAF 74LT3_0FAF 74LT3_EFAF<br />

243 75 75 150 — 112 3RW4445-6BC34 74MT3_BFAF 74MT3_DFAF 74MT3_0FAF 74MT3_EFAF<br />

263 75 100 200 — 149 3RW4446-6BC34 74NT3_BFAF 74NT3_DFAF 74NT3_0FAF 74NT3_EFAF<br />

326 100 125 250 — 186 3RW4447-6BC34 74PT3_BFAF 74PT3_DFAF 74PT3_0FAF 74PT3_EFAF<br />

494 150 150 400 — 298 3RW4453-6BC34 74QT3_BFAF 74QT3_0FAF<br />

551 150 200 450 — 336 3RW4454-6BC34 74RT3_BFAF 74RT3_0FAF<br />

615 200 200 500 — 373 3RW4455-6BC34 74ST3_BFAF 74ST3_0FAF<br />

634 200 250 500 — 373 3RW4456-6BC34 74TT3_BFAF 74TT3_0FAF<br />

650 200 250 550 — 373 3RW4457-6BC34 74WT3_BFAF 74WT3_0FAF<br />

200V 6 6 6 6 6<br />

230V 2 2 2 2 2<br />

380V 3 3 3 3 3<br />

460V 4 4 4 4 4<br />

26 — — 15 20 — 3RW4422-1BC35 74AT35BFAF 74AT35DFAF 74AT350FAF 74AT35EFAF 74AT35WFAF<br />

32 — — 20 25 — 3RW4423-1BC35 74BT35BFAF 74BT35DFAF 74BT350FAF 74BT35EFAF 74BT35WFAF<br />

42 — — 25 30 — 3RW4424-1BC35 74CT35BFAF 74CT35DFAF 74CT350FAF 74CT35EFAF 74CT35WFAF<br />

51 — — 30 40 — 3RW4425-1BC35 74DT35BFAF 74DT35DFAF 74DT350FAF 74DT35EFAF 74DT35WFAF<br />

68 — — 50 50 — 3RW4426-1BC35 74ET35BFAF 74ET35DFAF 74ET350FAF 74ET35EFAF 74ET35WFAF<br />

82 — — 60 75 — 3RW4427-1BC35 74FT35BFAF 74FT35DFAF 74FT350FAF 74FT35EFAF 74FT35WFAF<br />

97 — — 60 75 — 3RW4434-6BC35 74GT35BFAF 74GT35DFAF 74GT350FAF 74GT35EFAF 74GT35WFAF<br />

113 — — 75 100 — 3RW4435-6BC35 74HT35BFAF 74HT35DFAF 74HT350FAF 74HT35EFAF 74HT35WFAF<br />

134 — — 75 125 — 3RW4436-6BC35 74JT35BFAF 74JT35DFAF 74JT350FAF 74JT35EFAF 74JT35WFAF<br />

175 — — 100 150 — 3RW4443-6BC35 74KT35BFAF 74KT35DFAF 74KT350FAF 74KT35EFAF<br />

195 — — 125 200 — 3RW4444-6BC35 74LT35BFAF 74LT35DFAF 74LT350FAF 74LT35EFAF<br />

243 — — 150 200 — 3RW4445-6BC35 74MT35BFAF 74MT35DFAF 74MT350FAF 74MT35EFAF<br />

263 — — 200 250 — 3RW4446-6BC35 74NT35BFAF 74NT35DFAF 74NT350FAF 74NT35EFAF<br />

326 — — 250 300 — 3RW4447-6BC35 74PT35BFAF 74PT35DFAF 74PT350FAF 74PT35EFAF<br />

494 — — 400 500 — 3RW4453-6BC35 74QT35BFAF 74QT350FAF<br />

551 — — 450 550 — 3RW4454-6BC35 74RT35BFAF 74RT350FAF<br />

615 — — 500 600 — 3RW4455-6BC35 74ST35BFAF 74ST350FAF<br />

693 — — 550 650 — 3RW4456-6BC35 74TT35BFAF 74TT350FAF<br />

780 — — 600 700 — 3RW4457-6BC35 74WT35BFAF 74WT350FAF<br />

a Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor. b Starter selection is dependent on type of application. Im = FLA rating of motor.<br />

HPs are for reference only. Enclosed ratings are at 40°C.<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Product Category: IEC<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-233


Control Products<br />

Revised on 05/31/20<br />

Factory Modifications<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Modification<br />

Available modifications in STANDARD enclosure<br />

3RW Version<br />

Enclosed Style<br />

Enclosure<br />

NEMA Type<br />

Push Buttons<br />

Start/Stop 3RW40/44 73/74 ALL A1<br />

Emergency Stop 3RW40/44 73/74 ALL ES<br />

Selector Switches<br />

Hand-Off-Auto 3RW40/44 73/74 ALL A3<br />

Hand-Off-Auto w/ start pushbutton 3RW40/44 73/74 ALL S3<br />

Off-On 3RW40/44 73/74 ALL A4<br />

Pilot Light<br />

Red 'On' 3RW40/44 73/74 ALL FA<br />

Green 'On’ 3RW40/44 73/74 ALL FB<br />

Red 'Run’ 3RW40/44 73/74 ALL FC<br />

Green 'Run’ 3RW40/44 73/74 ALL FD<br />

LED Bulb Upgrade d 3RW40/44 73/74 ALL FE<br />

Red 'Off’ 3RW40/44 73/74 ALL FJ<br />

Green 'Off’ 3RW40/44 73/74 ALL FK<br />

Amber 'Fault' 3RW40/44 73/74 ALL FL<br />

White 'Control Power On' 3RW40/44 73/74 ALL FW<br />

Red, 'On’ Push-to-Test 3RW40/44 73/74 ALL FS<br />

Green 'On’ Push-to-Test 3RW40/44 73/74 ALL FT<br />

Green 'Off’ Push-to-Test 3RW40/44 73/74 ALL FU<br />

Custom pilot light (state color and nameplate text) 3RW40/44 73/74 ALL FZ<br />

Through the Door Metering<br />

External keypad for 3RW44 3RW44 73/74 1,12 K1<br />

Elapse time meter 3RW40/44 73/74 1,12 (120V) M5<br />

Control Options<br />

Profibus Communication Module (installed-connection cable not supplied) 3RW44 73/74 ALL P1<br />

Profinet Communication Module (installed-connection cable not supplied) 3RW44 73/74 ALL P2<br />

Ground Lug - 1 Conductor 3RW40/44 73/74 ALL L10<br />

Alarm Package (horn, light, relay & push button) 3RW40/44 73/74 1,3R,12 M7<br />

Electronic 8 function timing relay (.05s - 100h)<br />

24V/100-127V supplied mounted and unwired<br />

3RW40/44 73/74 ALL TR<br />

Control Relay supplied mounted<br />

and unwired (4 pole max)<br />

3RW40/44 73/74 ALL<br />

Circuit Breaker Shunt Trip (included std in 3RW40 versions) 3RW44 74 ALL L6<br />

Function identification plate w/ marking as specified 3RW40/44 73/74 ALL N1<br />

Service Entrance Labeled 3RW40/44 74 ALL N3<br />

Terminal Block 3 point 3RW40/44 73/74 ALL TC3<br />

Terminal Block 6 point 3RW40/44 73/74 ALL TC6<br />

Terminal Block 9 point 3RW40/44 73/74 ALL TC9<br />

Terminal Block 12 point 3RW40/44 73/74 ALL TC12<br />

Emergency HP Rated Bypass Starter ab<br />

3RW<br />

Enclosure<br />

Version Class NEMA Type Mod Suffix<br />

3RW40/44 73/74 1/12/3R/4 A12<br />

Mod Suffix<br />

R04<br />

R22<br />

R40<br />

Available Modifications<br />

Requiring the MODIFIED OPTIONS Box Size<br />

(to be used with the selections ending in GA*)<br />

3RW<br />

Version Class<br />

Enclosure<br />

NEMA Type Mod Suffix<br />

Isolation Contactor 3RW40/44 73/74 1/12/3R/4 IC<br />

100 VA Extra CPT Capacity 3RW40/44 73/74 ALL CA<br />

Space Heater (120V separate control) 3RW40/44 73/74 ALL SH<br />

Space Heater w/ T-stat (120V separate control) 3RW40/44 73/74 ALL ST<br />

Lightning Arrestor 3RW40/44 73/74 ALL L<br />

a (A) For sizes 73YT & 73ZT, mods IC & A12 are available individually or together;<br />

(B) For sizes 74YT & 74ZT (combination w\CB), mods IC & A12 are only available<br />

individually (NOT together); (C) For sizes 74YT & 74ZT (combination w\ fusible disc),<br />

mods IC & A12 are NOT available individually or together.<br />

An isolation contactor is included with the emergency HP rated bypass starter for<br />

version 3RW40 soft starters.<br />

Isolation contactor IC is included as standard with version 3RW40 model R (4th<br />

character of the cat. no.) soft starters.<br />

d Pilot lights are transformer type as standard. For LED type bulbs, order suffix FE in<br />

addition to the standard device suffix(es). For example, to order red “ON” and green<br />

“OFF” pilot lights with LED bulbs, order FA, FK and FE.<br />

17-234<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: IEC


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW30 for standard applications<br />

Overview<br />

The SIRIUS 3RW30 soft starters reduce the motor voltage<br />

through variable phase control and increase it in ramp-like mode<br />

from a selectable starting voltage up to mains voltage. During<br />

starting, these devices limit the torque as well as the current and<br />

prevent the shocks which arise during direct starts or wye-delta<br />

starts. In this way, mechanical loads and mains voltage dips can<br />

be reliably reduced.<br />

Soft starting reduces the stress on the connected equipment<br />

and results in lower wear and therefore longer periods of troublefree<br />

production. The selectable start value means that the soft<br />

starters can be adjusted individually to the requirements of the<br />

application in question and unlike wye-delta starters are not<br />

restricted to two-stage starting with fixed voltage ratios.<br />

The SIRIUS 3RW30 soft starters are characterized above all by<br />

their small space requirements. Integrated bypass contacts<br />

mean that no power loss has to be taken into the bargain at the<br />

power semiconductors (thyristors) after the motor has started<br />

up. This cuts down on heat losses, enabling a more compact<br />

design and making external bypass circuits superfluous.<br />

Various versions of the SIRIUS 3RW30 soft starters are available:<br />

• Standard version for fixed-speed three-phase motors, sizes<br />

S00, S0, S2 and S3, with integrated bypass contact system<br />

• Version for fixed-speed three-phase motors in a 22.5 mm<br />

enclosure without bypass<br />

Soft starters rated up to 75Hp (at 460 V) for standard applications<br />

in three-phase networks are available. Extremely small<br />

sizes, low power losses and simple commissioning are just three<br />

of the many advantages of this soft starter.<br />

Function<br />

The space required by the compact SIRIUS 3RW30 soft starter<br />

is often only about one third of that required by a contactor assembly<br />

for wye-delta starting of comparable rating. This not only<br />

saves space in the control cabinet and on the standard mounting<br />

rail but also does away completely with the wiring work<br />

needed for wye-delta starters. This is notable in particular for<br />

higher motor ratings which are only rarely available as fully wired<br />

solutions.<br />

At the same time the number of cables from the starter to the<br />

motor is reduced from six to three. Compact dimensions, short<br />

start-up times, easy wiring and fast commissioning make themselves<br />

felt as clear-cut cost advantages.<br />

The bypass contacts of these soft starters are protected during<br />

operation by an integrated solid-state arc quenching system.<br />

This prevents damage to the bypass contacts in the event of a<br />

fault, e. g. brief disconnection of the control voltage, mechanical<br />

shocks or life-related component defects on the coil operating<br />

mechanism or main contact spring.<br />

The new series of devices comes with the "polarity balancing"<br />

control method, which is designed to prevent direct current<br />

components in two-phase controlled soft starters. On two-phase<br />

controlled soft starters the current resulting from superimposition<br />

of the two controlled phases flows in the uncontrolled phase.<br />

This results for physical reasons in an asymmetric distribution of<br />

the three phase currents during the motor ramp-up. This phenomenon<br />

cannot be influenced, but in most applications it is<br />

non-critical.<br />

Controlling the power semiconductors results not only in this unbalance,<br />

however, but also in the previously mentioned direct<br />

current components which can cause severe noise generation<br />

on the motor at starting voltages of less than 50 %. The control<br />

method used for these soft starters eliminates these direct current<br />

components during the ramp-up phase and prevents the<br />

braking torque which they can cause.<br />

It creates a motor ramp-up that is uniform in speed, torque and<br />

current rise, thus permitting a particularly gentle, two-phase<br />

starting of the motors. At the same time the acoustic quality of<br />

the starting operation comes close to the quality of a threephase<br />

controlled soft starter. This is made possible by the ongoing<br />

dynamic harmonizing and balancing of current half-waves<br />

of different polarity during the motor ramp-up. Hence the name<br />

"polarity balancing".<br />

• Soft starting with voltage ramp; the starting voltage setting<br />

range U s is 40 % to 100 % and the ramp time t R can be set<br />

from 0 s to 20 s<br />

• Integrated bypass contact system to minimize power loss<br />

• Setting with two potentiometers<br />

• Simple mounting and commissioning<br />

• Mains voltages at 50/60 Hz, 200 to 480 V<br />

• Two control voltage versions 24 V AC/DC and 110 to<br />

230 V AC/DC<br />

• Wide temperature range from -25 °C to +60 °C<br />

• The built-in auxiliary contact ensures user-friendly control and<br />

possible further processing within the system (for status<br />

graphs see page 17-245)<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-235


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW30 for standard applications<br />

Technical specifications<br />

Soft Starter<br />

Control<br />

Type 3RW30 1. , 3RW30 2. 3RW30 3., 3RW30 4.<br />

Control electronics<br />

Rated values<br />

Terminal<br />

Rated control supply voltage<br />

A1/A2 V 24 110 ... 230 24 110 ... 230<br />

• Tolerance<br />

% ±20 -15/+10 ±20 -15/+10<br />

Rated control supply current<br />

• STANDBY<br />

mA < 50 6 20 < 50<br />

• During pick-up<br />

mA < 100 15 < 4000 < 500<br />

• ON<br />

mA < 100 15 20 < 50<br />

Rated frequency<br />

Hz 50/60<br />

• Tolerance<br />

% ±10<br />

Control input<br />

IN<br />

ON/OFF<br />

Power consumption with version<br />

• 24 V DC<br />

mA Approx. 12<br />

• 110/230 V AC<br />

mA AC: 3/6; DC: 1.5/3<br />

Relay outputs<br />

Output<br />

1<br />

ON 13/14<br />

Operating indication (NO)<br />

Rated operational current<br />

A 3 AC-15/AC-14 at 230 V,<br />

A 1 DC-13 at 24 V<br />

Protection against overvoltages<br />

Protection by means of varistor through contact<br />

Short-circuit protection<br />

4 A gL/gG operational class;<br />

6 A quick (fuse is not included in scope of supply)<br />

Operating indications LEDs DEVICE STATE/BYPASSED/<br />

FAILURE<br />

DEVICE STATE/BYPASSED/<br />

FAILURE<br />

Off Green Off Green Off<br />

Start Green Green flashing Green Green flashing<br />

Bypass Green Green Green Green<br />

Error signals<br />

• 24 V DC: U < 0.75 x U s or U > 1.25 x U s Off Red Off Red<br />

• 110 ... 230 V AC: U < 0.75 x U s or U > 1.15 x U s Off Red Off Red<br />

Electrical overloading of bypass<br />

Yellow Red -- --<br />

(reset by removing IN command)<br />

Missing mains voltage, phase failure, missing load Green Red Green Red<br />

Device fault Red Red Red Red<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Type 3RW30 1. ... 3RW30 4.<br />

Factory default<br />

Control times and parameters<br />

Control times<br />

C losing time (with connected control voltage)<br />

ms < 50<br />

C losing time (automatic/mains contactor mode)<br />

ms < 300<br />

Mains failure bridging time<br />

Control<br />

supply voltage<br />

ms 50<br />

Mains failure response time 1)<br />

Load circuit<br />

ms<br />

500<br />

Starting parameters<br />

• Starting time<br />

s 0 ... 20 7.5<br />

• Starting voltage<br />

% 40 ... 100 40<br />

Start-up detection<br />

No<br />

Operating mode output 13/14<br />

Rising edge at<br />

Start command ON<br />

Falling edge at<br />

Off command<br />

1) Mains failure detection only in standby state, not during operation.<br />

17-236<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW30 for standard applications<br />

Type<br />

3RW30 1.-.BB.4 ... 3RW30 4.-.BB.4<br />

Power electronics<br />

Rated operational voltage V AC 200 ... 480<br />

Tolerance<br />

% -15/+10<br />

Rated frequency Hz 50/60<br />

T olerance<br />

% ±10<br />

Uninterrupted duty at 40 °C (% of I e ) % 115<br />

Minimum load (% of I e ) % 10 (at least 2 A)<br />

Maximum cable length between soft starter and motor m 300<br />

Permissible installation height m 5000<br />

(derating from 1000, see characteristic curves); higher on request<br />

Permissible mounting position<br />

(auxiliary fan not available)<br />

10° 10°<br />

10° 10°<br />

NSB0_01897<br />

Permissible ambient temperature<br />

Operation<br />

°C -25 ... +60; (derating from +40)<br />

Storage<br />

°C -40 ... +80<br />

Degree of protection IP20 for 3RW30 1. and 3RW30 2.;<br />

IP00 for 3RW30 3. and 3RW30 4.<br />

Type 3RW30 13 3RW30 14 3RW30 16 3RW30 17 3RW30 18<br />

Power electronics 40 °C/50 °C/60 °C<br />

Load rating with rated operational current I e<br />

• Acc. to IEC and UL/CSA 1) , for individual mounting at 40/50/60 °C, A 3.6/3.3/3 6.5/6/5.5 9/8/7 12.5/12/11 17.6/17/14<br />

AC-53a<br />

Power loss<br />

• In operation after completed starting with uninterrupted rated operational<br />

W 0.25 0.5 1 2 4<br />

current (40 °C) approx.<br />

• During starting with 300 % I M ( 40 °C)<br />

W 6 13 20 20 29<br />

Permissible rated motor current and starts per hour<br />

for normal starting (Class 10)<br />

2)<br />

- Rated motor current I M , starting time 10 s<br />

A 3.6/3.3/3 6.5/6/5.5 9/8/7 12.5/12/11 17.6/17/14<br />

- Starts per hour 3) 1/h 200/150/70 87/60/50 50 85/70/60 62/46/60<br />

- Rated motor current I<br />

2)<br />

M , starting time 20 s<br />

A 3.6/3.3/3 6.5/6/5.5 9/8/7 12.5/12/11 17.6/17/14<br />

- Starts per hour 3) 1/h 150/100/50 64/46/28 35 62/47/37 45/32/43<br />

1) Measurement at 60 °C according to UL/CSA not required.<br />

3) For intermittent duty S4 with ON period = 30 %, T u = 40 °C, stand-alone<br />

2) With 300 % I M .<br />

installation vertical. The quoted switching frequencies do not apply for<br />

automatic mode.<br />

Type 3RW30 26 3RW30 27 3RW30 28<br />

Power electronics 40 °C/50 °C/60 °C<br />

Load rating with rated operational current I e<br />

• Acc. to IEC and UL/CSA 1) , for individual mounting at 40/50/60 °C, A 25.3/23/21 32.2/29/26 38/34/31<br />

AC-53a<br />

Power loss<br />

• In operation after completed starting with uninterrupted rated operational<br />

W 8 13 19<br />

current (40 °C) approx.<br />

• During starting with 300 % I M ( 40 °C)<br />

W 47 55 64<br />

Permissible rated motor current and starts per hour<br />

for normal starting (Class 10)<br />

- Rated motor current I<br />

2)<br />

M , starting time 10 s<br />

A 25/23/21 32/29/26 38/34/31<br />

- Starts per hour 3) 1/h 23 23 19<br />

2) - Rated motor current I M , starting time 20 s<br />

A 25/23/21 32/29/26 38/34/31<br />

- Starts per hour 3) 1/h 15 16 12<br />

1) Measurement at 60 °C according to UL/CSA not required.<br />

With 300 % I M .<br />

3) For intermittent duty S4 with ON period = 30 %, T u = 40 °C, stand-alone<br />

installation vertical. The quoted switching frequencies do not apply for<br />

automatic mode.<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-237


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW30 for standard applications<br />

Type 3RW30 36 3RW30 37 3RW30 38 3RW30 46 3RW30 47<br />

Power electronics 40 °C/50 °C/60 °C<br />

Load rating with rated operational current I e<br />

• Acc. to IEC and UL/CSA 1) , for individual mounting at 40/50/60 °C, A 45/42/39 63/58/53 72/63/60 80/73/66 106/98/90<br />

AC-53a<br />

Power loss<br />

• In operation after completed starting with uninterrupted rated operational<br />

W 6 12 15 12 21<br />

current (40 °C) approx.<br />

• During starting with 300 % I M ( 40 °C)<br />

W 79 111 125 144 192<br />

Permissible rated motor current and starts per hour<br />

for normal starting (Class 10)<br />

- Rated motor current I<br />

2)<br />

M , starting time 10 s<br />

A 45/42/39 63/58/53 72/63/60 80/73/66 106/98/90<br />

- Starts per hour 3) 1/h 38 23 22 22 15<br />

2) - Rated motor current I M , starting time 20 s<br />

A 45/42/39 63/58/53 72/63/60 80/73/66 106/98/90<br />

- Starts per hour 3) 1/h 26 15 15 15 10<br />

1) Measurement at 60 °C according to UL/CSA not required.<br />

2) With 300 % I M .<br />

3) For intermittent duty S4 with ON period = 30 %, T u = 40 °C, stand-alone<br />

installation vertical. The quoted switching frequencies do not apply for<br />

automatic mode.<br />

CONTROL<br />

PRODUCTS<br />

17<br />

Soft Starter<br />

Control<br />

17-238<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW30 for standard applications<br />

Soft starters Type 3RW30 1. 3RW30 2. 3RW30 3. 3RW30 4.<br />

Conductor cross-sections<br />

Screw terminals Main conductors<br />

Front clamping point<br />

connected<br />

Rear clamping point<br />

connected<br />

Both clamping points<br />

connected<br />

• Solid<br />

2<br />

mm<br />

2 x (1 ... 2.5);<br />

2 x (2.5 ... 6) acc.<br />

to IEC 60947<br />

• Finely stranded with end sleeve mm 2 2 x (1.5 ... 2.5);<br />

2 x (2.5 ... 6)<br />

Stranded<br />

mm<br />

• AWG cables<br />

Solid<br />

AWG<br />

Solid or stranded<br />

AWG<br />

Stranded<br />

AWG<br />

Solid<br />

mm<br />

2 x (1 ... 2.5);<br />

2 x (2.5 ... 6) acc.<br />

to IEC 60947;<br />

max. 1 x 10<br />

2 x (1 ... 2.5);<br />

2 x (2.5 ... 6)<br />

2 x (1.5 ... 16) 2 x (2.5 ... 16)<br />

1 x (0.75 ... 25) 1 x (2.5 ... 35)<br />

• 2 -- -- 1 x (0.75 ... 35) 1 x (4 ... 70)<br />

- 2 x (16 ... 12) 2 x (16 ... 12)<br />

- 2 x (14 ... 10) 2 x (14 ... 10) 1 x (18 ... 2) 1 x (10 ... 2/0)<br />

- 1 x 8 1 x 8 -- --<br />

• 2 -- -- 2 x (1.5 ... 16) 2 x (2.5 ... 16)<br />

• Finely stranded with end sleeve mm 2 -- -- 1 x (1.5 ... 25) 1 x (2.5 ... 50)<br />

• Stranded<br />

2<br />

mm -- -- 1 x (1.5 ... 35) 1 x (10 ... 70)<br />

• AWG cables<br />

- Solid or stranded<br />

AWG -- -- 1 x (16 ... 2) 1 x (10 ... 2/0)<br />

• Solid<br />

2 mm -- -- 2 x (1.5 ... 16) 2 x (2.5 ... 16)<br />

• Stranded<br />

mm2 -- -- 2 x (1.5 ... 25) 2 x (10 ... 50)<br />

• Finely stranded with end sleeve mm 2 -- -- 2 x (1.5 ... 16) 2 x (2.5 ... 35)<br />

• AWG cables<br />

- Solid or stranded<br />

AWG -- -- 2 x (16 ... 2) 2 x (10 ... 1/0)<br />

Soft Starter<br />

Control<br />

Spring-type terminals<br />

Busbar connections<br />

• Tightening torque<br />

NM 2 ... 2.5 2 ... 2.5 4.5 6.5<br />

lb.in 18 ... 22 18 ... 22 40 58<br />

Tools PZ 2 PZ 2 PZ 2 Allen screw 4 mm<br />

Degree of protection IP20 IP20 IP20<br />

(IP00 terminal<br />

compartment)<br />

IP20<br />

(IP00 terminal<br />

compartment)<br />

Main conductors<br />

• Solid<br />

2<br />

mm 1 ... 4 1 ... 10 -- --<br />

• Finely stranded with end sleeve mm 2 1 ... 2.5 1 ... 6, end -- --<br />

sleeves without<br />

plastic collar<br />

• AWG cables<br />

- Solid or stranded (finely stranded) AWG 16 ... 14 16 ... 10 -- --<br />

- Stranded<br />

AWG 16 ... 12 1 x 8 -- --<br />

Tools DIN ISO 2380-<br />

1A0; 5 x 3<br />

DIN ISO 2380-<br />

1A0; 5 x 3<br />

-- --<br />

Degree of protection IP20 IP20 -- --<br />

Main conductors<br />

• With cable lug acc. to DIN 46234 or max.<br />

20 mm wide<br />

- Stranded<br />

2<br />

mm -- -- -- 2 x (10 ... 70)<br />

- Finely stranded<br />

2 mm -- -- -- 2 x (10 ... 50)<br />

• AWG cables, solid or stranded AWG -- -- -- 2 x (7 ... 1/0)<br />

17 CONTROL<br />

PRODUCTS<br />

Soft starters Type 3RW30 1. ... 3RW30 4.<br />

Conductor cross-sections<br />

Auxiliary conductors (1 or 2 conductors can be connected):<br />

Screw terminals<br />

• Solid<br />

2<br />

mm 2 x (0.5 ... 2.5)<br />

• Finely stranded with end sleeve mm 2 2 x (0.5 ... 1.5)<br />

• AWG cables<br />

- Solid or stranded<br />

AWG 2 x (20 ... 14)<br />

- Finely stranded with end sleeve AWG 2 x (20 ... 16)<br />

• Terminal screws<br />

- Tightening torque<br />

NM 0.8 ... 1.2<br />

lb.in 7 ... 10.3<br />

Spring-type terminals<br />

• Solid<br />

mm2 2 x (0.25 ... 2.5)<br />

• Finely stranded with end sleeve mm 2 2 x (0.25 ... 1.5)<br />

• AWG cables, solid or stranded AWG 2 x (24 ... 14)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-239


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW30 for standard applications<br />

Soft Starter<br />

Control<br />

Type 3RW30 03<br />

Control electronics<br />

Rated values<br />

Rated control supply voltage<br />

V 24 ... 230 AC/DC<br />

• Tolerance<br />

% ± 10<br />

Rated control supply current<br />

mA 25 ... 4<br />

Rated frequency at AC<br />

Hz 50/60<br />

• Tolerance<br />

% ± 10<br />

Starting time s 0.1 ... 20 (adjustable)<br />

Starting voltage % 40 ... 100 (adjustable)<br />

Ramp-down time s 0 ... 20 (adjustable)<br />

Power electronics<br />

Rated operational voltage V AC 200 ... 400<br />

T olerance<br />

% ± 10<br />

Rated frequency Hz 50/60<br />

T olerance<br />

% ±10<br />

Uninterrupted duty (% of I e ) % 100<br />

Minimum load 1) (% of I e );<br />

at 40 °C<br />

% 9<br />

Maximum conductor length between soft starter and motor m 100 2)<br />

Degree of protection acc. to IEC 60529<br />

IP20 (IP00 terminal compartment)<br />

Permissible installation height m 5000<br />

(derating from 1000, see characteristic curves); higher on request<br />

Permissible mounting position<br />

10°<br />

10°<br />

10° 10°<br />

NSB0_01897<br />

Permissible ambient temperature<br />

Operation<br />

°C -25 ... +60; (derating from +40)<br />

Storage<br />

°C -40 ... +80<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Load rating with rated operational current I e<br />

• Acc. to IEC and UL/CSA 1) , for individual mounting, AC-53a<br />

- At 40 °C<br />

A 3<br />

- At 50 °C<br />

A 2.6<br />

- At 60 °C<br />

A 2.2<br />

• Acc. to IEC and UL/CSA 1) , for butt-mounting, AC-53a<br />

- At 40 °C<br />

A 2.6<br />

- At 50 °C<br />

A 2.2<br />

- At 60 °C<br />

A 1.8<br />

Power loss<br />

• In operation after completed starting with uninterrupted rated operational<br />

W 6.5<br />

current (40 °C) approx.<br />

• At utilization of max. switching frequency<br />

W 3<br />

Permissible starts per hour<br />

• For intermittent duty S4, T u = 40 °C, stand-alone installation vertical 1/h 1500<br />

• ON period = 70 %<br />

% I e /s 300/0.2<br />

Conductor cross-sections<br />

Screw terminals<br />

(1 or 2 conductors connectable)<br />

For standard screwdriver<br />

size 2 and Pozidriv 2<br />

Spring-type terminals<br />

• Main conductors<br />

- Solid<br />

mm² 1 x (0.5 ... 4);<br />

2 x (0.5 ... 2.5)<br />

- Finely stranded with end sleeve mm² 1 x (0.5 ... 2.5);<br />

2 x (0.5 ... 1.5)<br />

- Stranded<br />

mm² --<br />

- AWG cables,<br />

AWG 2 x (20 ... 14)<br />

solid or stranded<br />

- Terminal screws M3, PZ2<br />

- Tightening torque NM 0.8 ... 1.2<br />

lb.in 7.1 ... 8.9<br />

• Auxiliary conductors<br />

- Solid<br />

mm² 1 x (0.5 ... 4);<br />

2 x (0.5 ... 2.5)<br />

- Finely stranded with end sleeve mm² 1 x (0.5 ... 2.5); 2 x (0.5 ... 1.5)<br />

- AWG cables,<br />

AWG 2 x (20 ... 14)<br />

solid or stranded<br />

- Terminal screws M3, PZ2<br />

- Tightening torque NM 0.8 ... 1.2<br />

lb.in 7 ... 8.9<br />

Main and auxiliary conductors<br />

• Solid<br />

2<br />

mm 2 x (0.25 ... 1.5)<br />

• Finely stranded with end sleeve mm 2 2 x (0.25 ... 1)<br />

• AWG cables,<br />

mm 2 2 x (24 ... 16)<br />

solid or stranded<br />

1) The rated motor current (specified on the motor's name plate) should at<br />

least amount to the specified percentage of the SIRIUS soft starter unit's<br />

rated operational current I e .<br />

2) If this value is exceeded, problems with line capacities may arise, which<br />

can result in false firing.<br />

17-240<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW30 for standard applications<br />

Standard Parameters<br />

Electromagnetic compatibility Acc. to EN 60947-4-2<br />

EMC interference immunity<br />

Electrostatic discharge (ESD) EN 61000-4-2 ±4 kV contact discharge, ±8 kV air discharge<br />

Electromagnetic RF fields EN 61000-4-3 Frequency range: 80 ... 2000 MHz with 80 % at 1 kHz<br />

Degree of severity 3: 10 V/m<br />

Conducted RF interference EN 61000-4-6 Frequency range: 150 kHz ... 80 MHz with 80 % at 1 kHz<br />

Interference 10 V<br />

RF voltages and RF currents on cables<br />

• Burst EN 61000-4-4 ±2 kV/5 kHz<br />

• Surge EN 61000-4-5 ±1 kV line to line<br />

±2 kV line to earth<br />

EMC interference emission<br />

EMC interference field strength EN 55011 Limit value of Class A at 30 ... 1000 MHz,<br />

limit value of Class B for 3RW30 2.; 24 V AC/DC<br />

Radio interference voltage EN 55011 Limit value of Class A at 0.15 ... 30 MHz,<br />

limit value of Class B for 3RW30 2.; 24 V AC/DC<br />

Radio interference suppression filters<br />

Degree of noise suppression A (industrial applications)<br />

Not required<br />

Degree of noise suppression B (applications for residential areas)<br />

Control voltage<br />

• 230 V AC/DC Not available 1)<br />

• 24 V AC/DC Not required for 3RW30 1. and 3RW30 2.;<br />

required for 3RW30 3. and 3RW30 4. (see Table)<br />

1) Degree of noise suppression B cannot be obtained through the use of<br />

filters as the strength of the electromagnetic field is not attenuated by the<br />

filter.<br />

Soft Starter<br />

Control<br />

Soft starter type Rated current Recommended filters 1)<br />

Soft starters Voltage range 200 ... 480 V<br />

Filter type Rated current filters Terminals<br />

A A mm 2<br />

3RW30 36 45 4EF1512-1AA10 50 16<br />

3RW30 37 63 4EF1512-2AA10 66 25<br />

3RW30 38 72 4EF1512-3AA10 90 25<br />

3RW30 46 80 4EF1512-3AA10 90 25<br />

3RW30 47 106 4EF1512-4AA10 120 50<br />

1) The radio interference suppression filter is used to remove the conducted<br />

interference from the main circuit. The field-related emissions comply with<br />

degree of noise suppression B. Filter selection applies under standard<br />

conditions: 10 starts per hour, start time 4 s at 300 % I e .<br />

Type Number Max. Fuse Class K5, RK5, RK1 Max. Fuse Class J Short Voltage Circuit Voltage<br />

Standard short circuit ratings 3RW30<br />

3RW30 13 -- 15 A 5 kA 480 V<br />

3RW30 14 -- 25 A 5 kA 480 V<br />

3RW30 16 -- 36 A 5 kA 480 V<br />

3RW30 17 -- 50 A 5 kA 480 V<br />

3RW30 18 -- 60 A 5 kA 480 V<br />

3RW30 26 100 A 100 A 5 kA 480 V<br />

3RW30 27 125 A 125 A 5 kA 480 V<br />

3RW30 28 125 A 125 A 5 kA 480 V<br />

3RW30 36 175 A 175 A 10 kA 480 V<br />

3RW30 37 250 A 250 A 10 kA 480 V<br />

3RW30 38 250 A 250 A 10 kA 480 V<br />

3RW30 46 -- 300 A 10 kA 480 V<br />

3RW30 47 -- 350 A 10 kA 480 V<br />

High capacity short circuit ratings 3RW30<br />

3RW30 13 -- 15 A 42 kA 480 V<br />

3RW30 14 -- 25 A 42 kA 480 V<br />

3RW30 16 -- 25 A 42 kA 480 V<br />

3RW30 17 -- 25 A 42 kA 480 V<br />

3RW30 18 -- 25 A 42 kA 480 V<br />

3RW30 26 60 A 100 A 42 kA 480 V<br />

3RW30 27 60 A 125 A 42 kA 480 V<br />

3RW30 28 60 A 125 A 42 kA 480 V<br />

3RW30 36 100 A 175 A 30 kA 480 V<br />

3RW30 37 100 A 200 A 30 kA 480 V<br />

3RW30 38 100 A 200 A 30 kA 480 V<br />

3RW30 46 110 A 200 A 42 kA 480 V<br />

3RW30 47 110 A 200 A 42 kA 480 V<br />

For solid-state motor controller, Type 3RW301: Applicable in an enclosure with minimum overall dimensions of 200 by 120 by 200 mm.<br />

For solid-state motor controller, Type 3RW302: Applicable in an enclosure with minimum overall dimensions of 370 by 175 by 195 mm.<br />

For solid-state motor controller, Type 3RW303: Applicable in an enclosure with minimum overall dimensions of 450 by 220 by 235 mm.<br />

For solid-state motor controller, Type 3RW304: Applicable in an enclosure with minimum overall dimensions of 450 by 220 by 235 mm.<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-241


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

Fuse assignment<br />

The type of coordination to which the motor feeder with soft<br />

starter is mounted depends on the application-specific requirements.<br />

Normally, fuseless mounting (combination of motor<br />

starter protector/circuit breaker and soft starter) is sufficient.<br />

3RW30 for standard applications<br />

If type of coordination "2" is to be fulfilled, semiconductor fuses<br />

must be fitted in the motor feeder.<br />

Fused version (line protection only)<br />

F1<br />

Q21<br />

Q11<br />

M<br />

3~<br />

NSB0_01936<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Soft starters Line protection, maximum Line contactors<br />

ToC<br />

1 Rated<br />

Rated current Size (optional)<br />

current<br />

Q11 F1 Q21<br />

Type A Type A<br />

Type of coordination "1" 1) : I q = 65 kA at 480 V 10 %<br />

3RW30 03 2) 3 3NA3 805 3) 20 000 3RT10 15<br />

3RW30 13 3.6 3NA3 803-6 10 000 3RT10 15<br />

3RW30 14 6.5 3NA3 805-6 16 000 3RT10 15<br />

3RW30 16 9 3NA3 807-6 20 000 3RT10 16<br />

3RW30 17 12.5 3NA3 810-6 25 000 3RT10 24<br />

3RW30 18 17.6 3NA3 814-6 35 000 3RT10 26<br />

3RW30 26 25 3NA3 822-6 63 00 3RT10 26<br />

3RW30 27 32 3NA3 824-6 80 00 3RT10 34<br />

3RW30 28 38 3NA3 824-6 80 00 3RT10 35<br />

3RW30 36 45 3NA3 130-6 100 1 3RT10 36<br />

3RW30 37 63 3NA3 132-6 125 1 3RT10 44<br />

3RW30 38 72 3NA3 132-6 125 1 3RT10 45<br />

3RW30 46 80 3NA3 136-6 160 1 3RT10 45<br />

3RW30 47 106 3NA3 136-6 160 1 3RT10 46<br />

1) The types of coordination are explained in more detail under "3RA1 Fuseless<br />

Load Feeders".<br />

The type of coordination "1" refers only to soft starters in combination with<br />

the stipulated protective device (motor starter protector/circuit<br />

breaker/fuse), not to any additional components in the feeder.<br />

1) The types of coordination are explained in more detail under "3RA1 Fuseless<br />

Load Feeders".<br />

The type of coordination "2" refers only to soft starters in combination with<br />

the stipulated protective device (motor starter protector/circuit<br />

breaker/fuse), not to any additional components in the feeder.<br />

2) I q = 50 kA at 400 V.<br />

3) No SITOR fuse required!<br />

Alternatively: 3NA3 803 (LV HRC00), 5SB2 21 (DIAZED),<br />

5SE2 206 (NEOZED).<br />

2) I q = 50 kA at 400 V.<br />

3) 3NA3 805-1 (LV HRC00), 5SB2 61 (DIAZED), 5SE2 201-6 (NEOZED)<br />

Fused version with 3NE1 SITOR fuses (semiconductor and line protection)<br />

For matching fuse bases see Catalog LV 1 under "SENTRON Switching and Protection Devices for<br />

F’1<br />

Power Distribution" ––> "Switch Disconnectors", and Catalog ET B1 under "BETA Protecting" ––><br />

Q21<br />

"SITOR Semiconductor Fuses" or go to<br />

Q11<br />

www.siemens.com/sitor ––>"Products" ––>"BETA Protecting"––>"SITOR"<br />

M<br />

3~<br />

NSB0_01937<br />

Soft starters All-range fuses Line contactors<br />

ToC<br />

2 Rated<br />

Rated current Size (optional)<br />

current<br />

Q11 F'1 Q21<br />

Type A Type A<br />

Type of coordination "2" 1) : I q = 65 kA at 480 V 10 %<br />

3RW30 03 2) 3 3NE1 813-0 3) 16 000 3RT10 15<br />

3RW30 13 3.6 3NE1 813-0 16 000 3RT10 15<br />

3RW30 14 6.5 3NE1 813-0 16 000 3RT10 15<br />

3RW30 16 9 3NE1 813-0 16 000 3RT10 16<br />

3RW30 17 12.5 3NE1 813-0 16 000 3RT10 24<br />

3RW30 18 17.6 3NE1 814-0 20 000 3RT10 26<br />

3RW30 26 25 3NE1 803-0 35 000 3RT10 26<br />

3RW30 27 32 3NE1 020-2 80 00 3RT10 34<br />

3RW30 28 38 3NE1 020-2 80 00 3RT10 35<br />

3RW30 36 45 3NE1 020-2 80 00 3RT10 36<br />

3RW30 37 63 3NE1 820-0 80 000 3RT10 44<br />

3RW30 38 72 3NE1 820-0 80 000 3RT10 45<br />

3RW30 46 80 3NE1 021-0 100 00 3RT10 45<br />

3RW30 47 106 3NE1 022-0 125 00 3RT10 46<br />

ToC<br />

1<br />

ToC<br />

2<br />

Type of coordination "1"<br />

Type of coordination "2"<br />

The types of coordination are explained in more detail<br />

under "3RA1 Fuseless Load Feeders".<br />

These types of coordination are indicated in the<br />

Technical specifications by gray backgrounds.<br />

17-242<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW30 for standard applications<br />

Fused version with 3NE3 SITOR fuses (semiconductor protection by fuse, line and overload protection by motor starter protector;<br />

alternatively, installation with contactor and overload relay possible)<br />

For matching fuse bases see Catalog LV 1 under "SENTRON<br />

Switching and Protection Devices for Power Distribution" ––><br />

F3<br />

F1<br />

"Switch Disconnectors", and Catalog ET B1 under "BETA<br />

Protecting" ––> "SITOR Semiconductor Fuses" or go to<br />

Q21<br />

Q1<br />

www.siemens.com/sitor ––>"Products" ––>"BETA Protecting"<br />

F3<br />

––>"SITOR"<br />

Q11<br />

Q11<br />

M<br />

3~<br />

NSB0_01938<br />

M<br />

3~<br />

NSB0_01939<br />

Soft starters Semiconductor fuses, minimum Semiconductor fuses, maximum Semiconductor fuses, minimum<br />

Rated current Rated current Size Rated current Size Rated current Size<br />

ToC<br />

2<br />

Q11 F3 F3 F3<br />

Type A Type A Type A Type A<br />

Type of coordination "2" 1) : I q = 65 kA at 480 V 10 %<br />

3RW30 03 2) 3 -- -- -- -- -- --<br />

3RW30 13 3.6 -- -- -- -- -- -- 3NE4 101 32 0<br />

3RW30 14 6.5 -- -- -- -- -- -- 3NE4 101 32 0<br />

3RW30 16 9 -- -- -- -- -- -- 3NE4 101 32 0<br />

3RW30 17 12.5 -- -- -- -- -- -- 3NE4 101 32 0<br />

3RW30 18 17.6 -- -- -- 3NE3 221 100 1 3NE4 101 32 0<br />

3RW30 26 25 -- -- -- 3NE3 221 100 1 3NE4 102 40 0<br />

3RW30 27 32 -- -- -- 3NE3 222 125 1 3NE4 118 63 0<br />

3RW30 28 38 -- -- -- 3NE3 222 125 1 3NE4 118 63 0<br />

3RW30 36 45 -- -- -- 3NE3 224 160 1 3NE4 120 80 0<br />

3RW30 37 63 -- -- -- 3NE3 225 200 1 3NE4 121 100 0<br />

3RW30 38 72 3NE3 221 100 1 3NE3 227 250 1 -- -- --<br />

3RW30 46 80 3NE3 222 125 1 3NE3 225 200 1 -- -- --<br />

3RW30 47 106 3NE3 224 160 1 3NE3 231 350 1 -- -- --<br />

Soft starters Semiconductor fuses max. Semiconductor fuses min. Semiconductor fuses max. Cylindrical fuses<br />

Rated current Rated current Size Rated current Size Rated current Size Rated current<br />

ToC<br />

2<br />

Q11 F3 F3 F3 F3<br />

Type A Type A Type A Type A Type A<br />

Type of coordination "2" 1) : I q = 65 kA at 480 V 10 %<br />

3RW30 03 2) 3 -- -- -- 3NE8 015-1 25 00 3NE8 015-1 25 00 3NC1 010 10<br />

3RW30 13 3.6 -- -- -- 3NE8 015-1 25 00 3NE8 015-1 25 00 3NC2 220 20<br />

3RW30 14 6.5 -- -- -- 3NE8 015-1 25 00 3NE8 015-1 25 00 3NC2 220 20<br />

3RW30 16 9 -- -- -- 3NE8 015-1 25 00 3NE8 015-1 25 00 3NC2 220 20<br />

3RW30 17 12.5 -- -- -- 3NE8 015-1 25 00 3NE8 018-1 63 00 3NC2 250 50<br />

3RW30 18 17.6 -- -- -- 3NE8 003-1 35 00 3NE8 021-1 100 00 3NC2 263 63<br />

3RW30 26 25 3NE4 117 50 0 3NE8 017-1 50 00 3NE8 021-1 100 00 3NC2 263 63<br />

3RW30 27 32 3NE4 118 63 0 3NE8 018-1 63 00 3NE8 022-1 125 00 3NC2 280 80<br />

3RW30 28 38 3NE4 118 63 0 3NE8 020-1 80 00 3NE8 022-1 125 00 3NC2 280 80<br />

3RW30 36 45 3NE4 120 80 0 3NE8 020-1 80 00 3NE8 024-1 160 00 3NC2 280 80<br />

3RW30 37 63 3NE4 121 100 0 3NE8 021-1 100 00 3NE8 024-1 160 00 -- --<br />

3RW30 38 72 -- -- -- 3NE8 022-1 125 00 3NE8 024-1 160 00 -- --<br />

3RW30 46 80 -- -- -- 3NE8 022-1 125 00 3NE8 024-1 160 00 -- --<br />

3RW30 47 106 -- -- -- 3NE8 024-1 160 00 3NE8 024-1 160 00 -- --<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Soft starters Line contactors Motor starter protectors Line protection, maximum<br />

Rated current (optional) 400 V +10 % Rated current Rated current Size<br />

ToC<br />

2<br />

Q11 Q21 Q1 F1<br />

Type A Type A Type A<br />

Type of coordination "2" 1) : I q = 65 kA at 480 V 10 %<br />

3RW30 03 2) 3 3RT10 15 3RV10 11-1EA10 4 3NA3 805 3) 20 000<br />

3RW30 13 3.6 3RT10 15 3RV10 21-1FA10 5 3NA3 803-6 10 000<br />

3RW30 14 6.5 3RT10 15 3RV10 21-1HA10 8 3NA3 805-6 16 000<br />

3RW30 16 9 3RT10 16 3RV10 21-1JA10 10 3NA3 807-6 20 000<br />

3RW30 17 12.5 3RT10 24 3RV10 21-1KA10 12.5 3NA3 810-6 25 000<br />

3RW30 18 17.6 3RT10 26 3RV10 21-1BA10 20 3NA3 814-6 35 000<br />

3RW30 26 25 3RT10 26 3RV10 31-4DA10 25 3NA3 822-6 63 00<br />

3RW30 27 32 3RT10 34 3RV10 31-4EA10 32 3NA3 824-6 80 00<br />

3RW30 28 38 3RT10 35 3RV10 31-4FA10 40 3NA3 824-6 80 00<br />

3RW30 36 45 3RT10 36 3RV10 31-4GA10 45 3NA3 130-6 100 1<br />

3RW30 37 63 3RT10 44 3RV10 41-4JA10 63 3NA3 132-6 125 1<br />

3RW30 38 72 3RT10 45 3RV10 41-4KA10 75 3NA3 132-6 125 1<br />

3RW30 46 80 3RT10 45 3RV10 41-4LA10 90 3NA3 136-6 160 1<br />

3RW30 47 106 3RT10 46 3RV10 41-4MA10 100 3NA3 136-6 160 1<br />

1) The types of coordination are explained under "3RA1 Fuseless Load<br />

Feeders". The type of coordination "2" refers only to soft starters in combination<br />

with the stipulated protective device (motor starter protector/circuit<br />

breaker/fuse), not to any additional components in the feeder.<br />

I q = 50 kA at 400 V.<br />

3NA3 805-1 (LV HRC00), 5SB2 61 (DIAZED).<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-243


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW30 for standard applications<br />

Characteristic curves<br />

Permissible installation height<br />

Operational rated current I in %<br />

e<br />

105<br />

100<br />

95<br />

90<br />

85<br />

80<br />

75<br />

70<br />

0 1000 2000 3000 4000 5000<br />

Mounting height in m<br />

At an installation height above 2000 m, the max. permissible operational<br />

voltage is reduced to 460 V.<br />

NSB0_01704<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

More information<br />

Application examples for normal starting (Class 10)<br />

Normal starting Class 10 (up to 20 s with 300 % I n motor ),<br />

The soft starter rating can be selected to be as high as the rating of the motor used<br />

Application Conveyor belt Roller conveyor Compressor Small fan Pump Hydraulic pump<br />

Starting parameters<br />

• Voltage ramp and current<br />

limiting<br />

- Starting voltage % 70 60 50 40 40 40<br />

- Starting time s 10 10 20 20 10 10<br />

Note:<br />

These tables present sample set values and device sizes. They<br />

are intended only for the purposes of information and are not<br />

binding. The set values depend on the application in question<br />

and must be optimized during commissioning.<br />

The soft starter dimensions should be checked where necessary<br />

with the Win-Soft Starter software or with the help of Technical<br />

Assistance.<br />

17-244<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW30 for standard applications<br />

Configuration<br />

The 3RW solid-state motor controllers are designed for easy<br />

starting conditions. In the event of deviating conditions or increased<br />

switching frequency, it may be necessary to choose a<br />

larger device. For accurate dimensioning, use the Win-Soft<br />

Starter selection and simulation program.<br />

If necessary, an overload relay for heavy starting must be selected<br />

where long starting times are involved. PTC sensors are<br />

recommended.<br />

In the motor feeder between the SIRIUS 3RW soft starter and the<br />

motor, no capacitive elements are permitted (e. g. no reactivepower<br />

compensation equipment). In addition, neither static systems<br />

for reactive-power compensation nor dynamic PFC (Power<br />

Factor Correction) must be operated in parallel during starting<br />

and ramp-down of the soft starter. This is important to prevent<br />

faults arising on the compensation equipment and/or the soft<br />

starter.<br />

All elements of the main circuit (such as fuses, controls and<br />

overload relays) should be dimensioned for direct starting, following<br />

the local short-circuit conditions. Fuses, controls and<br />

overload relays must be ordered separately. Please observe the<br />

maximum switching frequencies specified in the technical<br />

specifications.<br />

Note:<br />

When induction motors are switched on, voltage drops occur as<br />

a rule on starters of all types (direct starters, wye-delta starters,<br />

soft starters). The infeed transformer must always be dimensioned<br />

such that the voltage dip when starting the motor remains<br />

within the permissible tolerance. If the infeed transformer is dimensioned<br />

with only a small margin, it is best for the control voltage<br />

to be supplied from a separate circuit (independently of the<br />

main voltage) in order to avoid the potential switching off of the<br />

soft starter.<br />

Status graphs<br />

U<br />

U<br />

U<br />

N<br />

S<br />

ON 13/14<br />

t R on<br />

t R on<br />

Win-Soft Starter selection and simulation program<br />

With this software, you can simulate and select all Siemens soft<br />

starters, taking into account various parameters such as mains<br />

properties, motor and load data, and special application<br />

requirements.<br />

The software is a valuable tool, which makes complicated,<br />

lengthy manual calculations for determining the required soft<br />

starters superfluous.<br />

The Win-Soft Starter selection and simulation program can be<br />

downloaded from:<br />

www.usa.siemens.com/softstarters > Software<br />

More information can be found on the Internet at:<br />

www.usa.siemens.com/softstarters<br />

t<br />

t<br />

NSB0_01941<br />

Soft Starter<br />

Control<br />

Schematic circuit diagram<br />

L1<br />

T1<br />

A bypass contact system is already integrated in the 3RW30 soft<br />

starter and therefore does not have to be ordered separately.<br />

L2<br />

T2<br />

L3<br />

T3<br />

NSB0_01940<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-245


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW40 for standard applications<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Overview<br />

SIRIUS 3RW40 soft starters have all the same advantages as the<br />

3RW30 soft starters.<br />

The SIRIUS 3RW40 soft starters are characterized above all by<br />

their small space requirements. Integrated bypass contacts<br />

mean that no power loss has to be taken into the bargain at the<br />

power semiconductors (thyristors) after the motor has started<br />

up. This cuts down on heat losses, enabling a more compact design<br />

and making external bypass circuits superfluous.<br />

At the same time this soft starter comes with additional integrated<br />

functions such as adjustable current limiting, motor overload<br />

and intrinsic device protection, and optional thermistor motor<br />

protection. The higher the motor rating, the more important<br />

these functions because they make it unnecessary to purchase<br />

and install protection equipment such as overload relays.<br />

Internal intrinsic device protection prevents the thermal overloading<br />

of the thyristors and the power section defects this can<br />

cause. As an option the thyristors can also be protected by<br />

semiconductor fuses from short-circuiting.<br />

Thanks to integrated status monitoring and fault monitoring, this<br />

compact soft starter offers many different diagnostics options.<br />

Up to four LEDs and relay outputs permit differentiated monitoring<br />

and diagnostics of the operating mechanism by indicating<br />

the operating state as well as for example mains or phase failure,<br />

missing load, non-permissible tripping time/class setting, thermal<br />

overloading or device faults.<br />

Soft starters rated up to 300 Hp (at 460 V) for standard applications<br />

in three-phase networks are available. Extremely small<br />

sizes, low power losses and simple start-up are just three of the<br />

many advantages of the SIRIUS 3RW40 soft starters.<br />

"Increased safety" type of protection EEx e according to<br />

ATEXdirective 94/9/EC<br />

The 3RW40 soft starter sizes S0 to S12 are suitable for the starting<br />

of explosion-proof motors with "increased safety" type of protection<br />

EEx e.<br />

See "Appendix" –> "Standards and approvals" –> "Type overview<br />

of approved devices for potentially explosive areas (ATEX<br />

explosion protection)".<br />

Function<br />

The space required by the compact SIRIUS 3RW40 soft starter<br />

is often only about one third of that required by a contactor assembly<br />

for wye-delta starting of comparable rating. This not only<br />

saves space in the control cabinet and on the standard mounting<br />

rail but also does away completely with the wiring work<br />

needed for wye-delta starters. This is notable in particular for<br />

higher motor ratings which are only rarely available as fully wired<br />

solutions.<br />

At the same time the number of cables from the starter to the motor<br />

is reduced from six to three. Compact dimensions, short<br />

start-up times, easy wiring and fast commissioning make themselves<br />

felt as clear-cut cost advantages.<br />

The bypass contacts of these soft starters are protected during<br />

operation by an integrated solid-state arc quenching system.<br />

This prevents damage to the bypass contacts in the event of a<br />

fault, e. g. brief disconnection of the control voltage, mechanical<br />

shocks or life-related component defects on the coil operating<br />

mechanism or main contact spring.<br />

The starting current of particularly powerful operating mechanisms<br />

can place an unjustifiable load on the local supply system.<br />

Soft starters reduce this starting current by means of their voltage<br />

ramp. Thanks to the adjustable current limiting, the<br />

SIRIUS 3RW40 soft starter takes even more pressure off the supply<br />

system. It leaves the set start ramp during the ramp-up – the<br />

ramp gradient is fixed by the starting voltage and the ramp time<br />

– as soon as the selected current limit is reached. From this moment<br />

the voltage of the soft starter is controlled so that the current<br />

supplied to the motor remains constant. This process is<br />

ended either by completion of the motor ramp-up or by tripping<br />

by the intrinsic device protection or the motor overload protection.<br />

As the result of this function the actual motor ramp-up can<br />

well take longer than the ramp time selected on the soft starter.<br />

Thanks to the integrated motor overload protection<br />

according to IEC 60947-4-2 there is no need of an additional<br />

overload relay on the new soft starters. The rated motor current,<br />

the setting of the overload tripping time (Class times) and the reset<br />

of the motor overload protection function can be adjusted<br />

easily and quickly. Using a 4-step rotary potentiometer it is possible<br />

to set different overload tripping times on the soft starter. In<br />

addition to Class 10, 15 and 20 it is also possible to switch off the<br />

motor overload protection if a different motor management control<br />

device is to be used for this function, e. g. with connection to<br />

PROFIBUS.<br />

Device versions with thermistor motor protection evaluation are<br />

available up to a rating of 55 kW (at 400 V). A "Thermoclick" measuring<br />

probe can be connected directly, as can a PTC of type A.<br />

Thermal overloading of the motor, open circuits and short-circuits<br />

in the sensor circuit all result in the direct disconnection of<br />

the soft starter. And if ever the soft starter trips, various reset options<br />

are available the same as with intrinsic device protection<br />

and motor load protection: manually with the reset button, automatically<br />

or remotely through brief disconnection of the control<br />

voltage.<br />

The new series of devices comes with the "polarity balancing"<br />

control method, which is designed to prevent direct current<br />

components in two-phase controlled soft starters. On two-phase<br />

controlled soft starters the current resulting from superimposition<br />

of the two controlled phases flows in the uncontrolled phase.<br />

This results for physical reasons in an asymmetric distribution of<br />

the three phase currents during the motor ramp-up. This phenomenon<br />

cannot be influenced, but in most applications it is<br />

non-critical.<br />

Controlling the power semiconductors results not only in this unbalance,<br />

however, but also in the previously mentioned direct<br />

current components which can cause severe noise generation<br />

on the motor at starting voltages of less than 50 %.<br />

The control method used for these soft starters eliminates these<br />

direct current components during the ramp-up phase and prevents<br />

the braking torque which they can cause. It creates a motor<br />

ramp-up that is uniform in speed, torque and current rise,<br />

thus permitting a particularly gentle, two-phase starting of the<br />

motors. At the same time the acoustic quality of the starting operation<br />

comes close to the quality of a three-phase controlled<br />

soft starter. This is made possible by the on-going dynamic harmonizing<br />

and balancing of current half-waves of different polarity<br />

during the motor ramp-up. Hence the name "polarity<br />

balancing".<br />

17-246<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

As an option the thyristors can also be protected by SITOR semiconductor<br />

fuses from short-circuiting so that the soft starter is<br />

still functional after a short-circuit (type of coordination 2). Three<br />

LEDs are used to indicate the operating state as well as possible<br />

errors, e. g. non-permissible tripping time (CLASS setting),<br />

mains or phase failure, missing load, thermal overloading or device<br />

faults.<br />

• Soft starting with voltage ramp; the starting voltage setting<br />

range U s is 40 to 100 % and the ramp time t R can be set from<br />

0 to 20 s. 3)<br />

• Smooth ramp-down with voltage ramp; the running down time<br />

t off can be set between 0 s to 20 s. 3)<br />

• Solid-state motor overload and intrinsic device protection<br />

• Optional thermistor motor protection (up to size S3)<br />

• Remote reset (integrated up to size S3, optional for size S6 and<br />

larger)<br />

• Adjustable current limiting<br />

3RW40 for standard applications<br />

• Integrated bypass contact system to minimize power loss<br />

• Setting with potentiometers<br />

• Simple mounting and commissioning<br />

• Integrated status monitoring and fault monitoring<br />

• Mains voltages 50/60 Hz, 200 to 600 V<br />

• Various control voltage versions<br />

- Sizes S0 to S3:<br />

24 V AC/DC and<br />

110 to 230 V AC/DC<br />

- Sizes S6 to S12:<br />

115 V AC and 230 V AC.<br />

Control by way of the internal 24 V DC supply and direct control<br />

by means of PLC are possible.<br />

• Wide temperature range from -25 to +60 °C<br />

• Built-in auxiliary contacts ensure user-friendly control and possible<br />

further processing within the system (for status graphs<br />

see page 17-260)<br />

Technical specifications<br />

Type 3RW40 2. 3RW40 3., 3RW40 4.<br />

Control electronics<br />

Rated values<br />

Terminal<br />

Rated control supply<br />

voltage<br />

A1/A2 V 24 110 ... 230 24 110 ... 230<br />

• Tolerance<br />

% ±20 -15/+10 ±20 -15/+10<br />

Rated control supply current<br />

• STANDBY<br />

mA < 150 < 50 < 200 < 50<br />

• During pick-up<br />

mA < 200 < 100 < 5000 < 1500<br />

• ON without fan<br />

mA < 250 < 50 < 200 < 50<br />

• ON with fan<br />

mA < 300 < 70 < 250 < 70<br />

Rated frequency<br />

Hz 50/60<br />

• Tolerance<br />

% ±10<br />

Control inputs<br />

IN<br />

ON/OFF<br />

Rated operational current<br />

• AC<br />

mA Approx. 12 3/6 Approx. 12 3/6<br />

• DC<br />

mA Approx. 12 1.5/3 Approx. 12 1.5/3<br />

Relay outputs<br />

Output 1<br />

1)<br />

ON/RUN mode 13/14 Operating indication (NO)<br />

Output<br />

2<br />

BYPASSED<br />

23/24<br />

Bypass indication (NO)<br />

Output<br />

3<br />

OVERLOAD/FAILURE 95/96/98 Overload/error indication (NC/NO)<br />

Rated operational current<br />

A 3 AC-15/AC-14 at 230 V,<br />

A 1 DC-13 at 24 V<br />

Protection against overvoltages<br />

Short-circuit protection<br />

1) Factory default: ON mode.<br />

Protection by means of varistor through contact<br />

4 A gL/gG operational class;<br />

6 A quick (fuse is not included in scope of supply)<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Type 3RW40 5. 3RW40 7 .<br />

Control electronics<br />

Rated values<br />

Terminal<br />

Rated control supply voltage<br />

A1/A2 V AC<br />

115 230 115 230<br />

• Tolerance<br />

% -15/+10 -15/+10<br />

Rated control supply current STANDBY<br />

mA 15 15<br />

Rated control supply current ON 1) mA 440 200 660 360<br />

Rated frequency<br />

Hz 50/60 50/60<br />

• Tolerance<br />

% ±10 ±10<br />

Control inputs<br />

IN<br />

ON/OFF<br />

Rated operational current<br />

mA Approx. 10 acc. to DIN 19240<br />

Rated operational voltage<br />

V DC 24 from internal supply dc+ or<br />

external DC supply (acc. to DIN 19240) through terminals and IN<br />

Relay outputs<br />

Output<br />

1<br />

ON/RUN mode2) 13/14 Operating indication (NO)<br />

Output<br />

2<br />

BYPASSED<br />

23/24<br />

Bypass indication (NO)<br />

Output<br />

3<br />

OVERLOAD/FAILURE 95/96/98 Overload/error indication (NC/NO)<br />

Rated operational current<br />

A 3 AC-15/AC-14 at 230 V,<br />

A 1 DC-13 at 24 V<br />

Protection against overvoltages<br />

Protection by means of varistor through contact<br />

Short-circuit protection<br />

4 A gL/gG operational class;<br />

6 A quick (fuse is not included in scope of supply)<br />

1) Values for the coil power consumption at +10 % U n , 50 Hz.<br />

Factory default: ON mode.<br />

3) Actual motor start times are load dependent.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-247


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW40 for standard applications<br />

Type 3RW40 2., 3RW40 3., 3RW40 4.<br />

Control electronics<br />

Operating indications LEDs DEVICE STATE/BYPASSED/FAILURE OVERLOAD<br />

Off Green Off Off<br />

Start Green Green flashing Off<br />

Bypass Green Green Off<br />

Ramp-down Green Green flashing Off<br />

Alarm signals<br />

I e /Class setting not permissible Green Not relevant Red flashing<br />

Start inhibited/thyristors too hot Yellow flashing Not relevant Off<br />

Error signals<br />

• 24 V: U < 0.75 x U s or U > 1.25 x U s Off Red Off<br />

• 110 ... 230 V: U < 0.75 x U s or U > 1.15 x U s Off Red Off<br />

Non-permissible I e /Class setting<br />

for edge 0 –> 1 on input IN Green Red Red flashing<br />

Motor protection shut-down (overload thermistor) Green Off Red<br />

Thermistor defective (open circuit, short-circuit) Green Off Red flickering<br />

Thermal overloading of the thyristors Yellow Red Off<br />

Missing mains voltage, phase failure, missing load Green Red Off<br />

Device fault Red Red Off<br />

Soft Starter<br />

Control<br />

Type 3RW40 5. and 3RW40 7.<br />

Control electronics<br />

Operating indications LEDs DEVICE STATE/BYPASSED FAILURE OVERLOAD<br />

Off Green Off Off Off<br />

Start Green Green flashing Off Off<br />

Bypass Green Green Off Off<br />

Ramp-down Green Green flashing Off Off<br />

Alarm signals<br />

I e /Class setting not permissible Green Not relevant Not relevant Red flashing<br />

Start inhibited/thyristors too hot Yellow flashing Not relevant Not relevant Off<br />

CONTROL<br />

PRODUCTS<br />

17<br />

Error signals<br />

U < 0.75 x U s or U > 1.15 x U s Off Off Red Off<br />

Non-permissible I e /Class setting<br />

for edge 0 –> 1 on input IN Green Off Red Red flashing<br />

Motor protection shut-down Green Off Off Red<br />

Thermal overloading of the thyristors Yellow Off Red Off<br />

Missing mains voltage, phase failure, missing load Green Off Red Off<br />

Device fault Red Off Red Off<br />

17-248<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

Type 3RW40 . .<br />

Factory default<br />

Protection functions<br />

Motor protection functions<br />

Trips in the event of<br />

Thermal overloading of the motor<br />

Trip class to IEC 60947-4-1<br />

Class 10/15/20 10<br />

P hase failure sensitivity<br />

% > 40<br />

Overload warning<br />

No<br />

Thermistor protection acc. to IEC 60947-8, type A/IEC 60947-5-1 Yes 1)<br />

Reset option after tripping Manual/automatic/remote reset 2)<br />

(MAN/AUTO/REMOTE 2) )<br />

Recovery<br />

time<br />

min 5<br />

Device protection functions<br />

Trips in the event of<br />

1) Optional up to size S3 (device variant).<br />

2) Integrated remote reset (REMOTE) available only for 3RW40 2. to<br />

3RW40 4.; remote reset with 3RU19 accessory module available<br />

for 3RW40 5. and 3RW40 7..<br />

3) Bypass protection up to size S3.<br />

Thermal overloading of the thyristors or<br />

bypass 3)<br />

Reset option after tripping Manual/automatic/remote reset 2)<br />

(MAN/AUTO/REMOTE 2) )<br />

Recovery time<br />

• During overloading of the thyristors<br />

s 30<br />

• During overloading of the bypass<br />

s 60<br />

Control times and parameters<br />

Control times<br />

Closing time (with conn ected control voltage)<br />

ms<br />

< 50<br />

Closing time (automatic/ma ins contactor mode)<br />

ms<br />


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW40 for standard applications<br />

Type<br />

3RW40 2.-. .B.4,<br />

3RW40 3.-. .B.4,<br />

3RW40 4.-. .B.4<br />

3RW40 2.-. .B.5,<br />

3RW40 3.-. .B.5,<br />

3RW40 4.-. .B.5<br />

3RW40 5.-.BB.4,<br />

3RW40 7.-.BB.4<br />

3RW40 5.-.BB.5,<br />

3RW40 7.-.BB.5<br />

Power electronics<br />

Rated operational voltage V AC 200 ... 480 400 ... 600 200 ... 460 400 ... 600<br />

Tolerance<br />

% -15/+10 -15/+10 -15/+10 -15/+10<br />

Maximum blocking voltage (thyristor) V AC 1600 1400 1800<br />

Rated frequency Hz 50/60<br />

T olerance<br />

% ±10<br />

Uninterrupted duty at 40 °C (% of I e ) % 115<br />

Minimum load (% of minimum selectable rated motor current I M ) % 20 (at least 2 A)<br />

Maximum cable length between soft starter and motor m 300<br />

Permissible installation height m 5000<br />

(derating from 1000, see characteristic curves); higher on request<br />

Permissible mounting position<br />

• With auxiliary fan (for 3RW40 2. ... 3RW40 4.)<br />

Soft Starter<br />

Control<br />

• Without auxiliary fan (for 3RW40 2. ... 3RW40 4.)<br />

10° 10°<br />

Permissible ambient temperature<br />

Operation<br />

°C -25 ... +60; (derating from +40)<br />

Storage<br />

°C -40 ... +80<br />

Degree of protection IP20 for 3RW40 2.;<br />

IP00 for 3RW40 3. and 3RW40 4.<br />

10°<br />

10°<br />

NSB0_01897<br />

-- (fan integrated in the soft starter)<br />

IP00<br />

Type 3RW40 24 3RW40 26 3RW40 27 3RW40 28<br />

Power electronics 40 °C/50 °C/60 °C<br />

Load rating with rated operational current I e<br />

• Acc. to IEC and UL/CSA 1) , for individual mounting at 40/50/60 °C,<br />

AC-53a<br />

A 12.5/11/10 25.3/23/21 32.2/29/26 38/34/31<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Smallest adjustable rated motor current I M<br />

For<br />

the motor overload protection<br />

A 5 10 17 23<br />

Power loss<br />

• In operation after completed starting with uninterrupted rated W 2 8 13 19<br />

operational current (40 °C) approx.<br />

• During starting with 300 % I M ( 40°C)<br />

W 17 47 55 64<br />

Permissible rated motor current and starts per hour<br />

• Normal starting (Class 10)<br />

- Rated motor current I<br />

2)<br />

M , starting time 3 s<br />

A 12.5/11/10 25.3/23/21 32.2/29/26 38/34/31<br />

- Starts per hour 3) 1/h 50 23 23 19<br />

2)4) - Rated motor current I M , starting time 4 s<br />

A 12.5/11/10 25.3/23/21 32.2/29/26 38/34/31<br />

- Starts per hour 3) 1/h 36 15 16 12<br />

• Normal starting (Class 15)<br />

2) - Rated motor current I M , starting time 4.5 s<br />

A 11/10/9 25.3/23/21 32.2/29/26 38/34/31<br />

- Starts per hour 3) 1/h 49 21 18 18<br />

2)4)<br />

- Rated motor current I M , starting time 6 s<br />

A 11/10/9 25.3/23/21 32.2/29/26 38/34/31<br />

- Starts per hour 3) 1/h 36 14 13 13<br />

• Normal starting (Class 20)<br />

2)<br />

- Rated motor current I M , starting time 6 s<br />

A 10/9/8 21/19/17 27/24/21 31/28/25<br />

- Starts per hour 3) 1/h 47 21 20 18<br />

- Rated motor current I<br />

2)4)<br />

M , starting time 8 s<br />

A 10/9/8 21/19/17 27/24/21 31/28/25<br />

- Starts per hour 3) 1/h 34 15 14 13<br />

1) Measurement at 60 °C according to UL/CSA not required.<br />

2) With 300 % I M .<br />

3) For intermittent duty S4 with ON period = 30 %, T u = 40 °C, stand-alone<br />

installation vertical. The quoted switching frequencies do not apply for<br />

automatic mode.<br />

4) Maximum adjustable rated motor current I M , dependent on CLASS setting.<br />

17-250<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW40 for standard applications<br />

Type 3RW40 36 3RW40 37 3RW40 38 3RW40 46 3RW40 47<br />

Power electronics 40 °C/50 °C/60 °C<br />

Load rating with rated operational current I e<br />

• Acc. to IEC and UL/CSA 1) , for individual mounting at 40/50/60 °C,<br />

AC-53a<br />

A 45/42/39 63/58/53 72/63/60 80/73/66 106/98/90<br />

Smallest adjustable rated motor current I M<br />

For<br />

the motor overload protection<br />

A 23 26 35 43 46<br />

Power loss<br />

• In operation after completed starting with uninterrupted rated W 6 12 15 12 21<br />

operational current (40 °C) approx.<br />

• During starting with 300 % I M ( 40°C)<br />

W 79 111 125 144 192<br />

Permissible rated motor current and starts per hour<br />

• Normal starting (Class 10)<br />

- Rated motor current I<br />

2)<br />

M , starting time 3 s<br />

A 45/42/39 63/58/53 72/63/60 80/73/66 106/98/90<br />

- Starts per hour 3) 1/h 38 23 22 22 15<br />

2)4) - Rated motor current I M , starting time 4 s<br />

A 45/42/39 63/58/53 72/63/60 80/73/66 106/98/90<br />

- Starts per hour 3) 1/h 26 15 15 15 10<br />

• Normal starting (Class 15)<br />

2) - Rated motor current I M , starting time 4.5 s<br />

A 42/38/34 50/46/42 56/52/46 70/64/58 84/77/70<br />

- Starts per hour 3) 1/h 30 34 34 24 23<br />

2)4)<br />

- Rated motor current I M , starting time 6 s<br />

A 42/38/34 50/46/42 56/52/46 70/64/58 84/77/70<br />

- Starts per hour 3) 1/h 21 24 24 16 17<br />

• Normal starting (Class 20)<br />

2) - Rated motor current I M , starting time 6 s<br />

A 38/34/30 46/42/38 50/46/42 64/58/52 77/70/63<br />

- Starts per hour 3) 1/h 30 31 34 23 23<br />

2)4)<br />

- Rated motor current I M , starting time 8 s<br />

A 38/34/30 46/42/38 50/46/42 64/58/52 77/70/63<br />

- Starts per hour 3) 1/h 21 22 24 16 16<br />

1) Measurement at 60 °C according to UL/CSA not required.<br />

With 300 % I M .<br />

3) For intermittent duty S4 with ON period = 30 %, T u = 40 °C, stand-alone<br />

installation vertical. The quoted switching frequencies do not apply for<br />

automatic mode.<br />

4) Maximum adjustable rated motor current I M , dependent on CLASS setting.<br />

Soft Starter<br />

Control<br />

Type 3RW40 55 3RW40 56 3RW40 73 3RW40 74 3RW40 75 3RW40 76<br />

Power electronics 40 °C/50 °C/60 °C<br />

Load rating with rated operational current I e<br />

• Acc. to IEC and UL/CSA 1) , for individual mounting at 40/50/60 °C,<br />

AC-53a<br />

A 134/117/100 162/145/125 230/205/180 280/248/215 356/315/280 432/385/335<br />

Smallest adjustable rated motor current I M<br />

For<br />

the motor overload protection<br />

A 59 87 80 130 131 207<br />

Power loss<br />

• In operation after completed starting with uninterrupted rated W 60 75 75 90 125 165<br />

operational current (40 °C) approx.<br />

• During starting with 300 % 2) I M ( 40°C)<br />

W 1043 1355 2448 3257 3277 3600<br />

Permissible rated motor current and starts per hour<br />

• Normal starting (Class 10)<br />

2) - Rated motor current I M , starting time 10 s<br />

A 134/117/100 162/145/125 230/205/180 280/248/215 356/315/280 432/385/335<br />

- Starts per hour 3) 1/h 20 8 20 20 16 17<br />

2)4)<br />

- Rated motor current I M , starting time 20 s<br />

A 134/117/100 162/145/125 230/205/180 280/248/215 356/315/280 432/385/335<br />

- Starts per hour 3) 1/h 7 1.4 9 8 5 5<br />

• Normal starting (Class 15)<br />

2)<br />

- Rated motor current I M , starting time 15 s<br />

A 134/117/100 152/140/125 210/200/180 250/220/190 341/315/280 402/385/335<br />

- Starts per hour 3) 1/h 11 8 11 13 11 12<br />

- Rated motor current I<br />

2)4)<br />

M , starting time 30 s<br />

A 134/117/100 152/140/125 210/200/180 250/220/190 341/315/280 402/385/335<br />

- Starts per hour 3) 1/h 1.2 1.7 1 6 2 2<br />

• Normal starting (Class 20)<br />

- Rated motor current I<br />

2)<br />

M , starting time 20 s<br />

A 124/112/100 142/132/120 200/185/168 230/205/180 311/280/250 372/340/305<br />

- Starts per hour 3) 1/h 12 9 10 10 10 10<br />

2)4) - Rated motor current I M , starting time 40 s<br />

A 124/112/100 142/132/120 200/185/168 230/205/180 311/280/250 372/340/305<br />

- Starts per hour 3) 1/h 3 3 1 5 1 1<br />

1) Measurement at 60 °C according to UL/CSA not required.<br />

With 300 % I M .<br />

3) For intermittent duty S4 with ON period = 30 %, T u = 40 °C, stand-alone<br />

installation vertical. The quoted switching frequencies do not apply for<br />

automatic mode.<br />

4) Maximum adjustable rated motor current I M , dependent on CLASS setting.<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-251


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW40 for standard applications<br />

Soft Starter<br />

Control<br />

Soft starters Type 3RW40 2. 3RW40 3. 3RW40 4.<br />

Conductor cross-sections<br />

Screw terminals<br />

Front clamping point<br />

connected<br />

Rear clamping point<br />

connected<br />

Both clamping points<br />

connected<br />

Main conductors<br />

• Solid<br />

2<br />

mm<br />

2 x (1.5 ... 2.5);<br />

2 x (2.5 ... 6) acc. to<br />

IEC 60947;<br />

max. 1 x 10<br />

2 x (1.5 ... 16) 2 x (2.5 ... 16)<br />

• With end sleeve<br />

2 mm 2 x (1.5 ... 2.5);<br />

1 x (0.75 ... 25) 1 x (2.5 ... 35)<br />

2 x (2.5 ... 6)<br />

• Stranded<br />

2 mm -- 1 x (0.75 ... 35) 1 x (4 ... 70)<br />

• AWG cables<br />

- Solid<br />

AWG 2 x (16 ... 12)<br />

- Solid or stranded<br />

AWG 2 x (14 ... 10) 1 x (18 ... 2) 2 x (10 ... 1/0)<br />

- Stranded<br />

AWG 1 x 8 -- --<br />

• Solid<br />

mm2 -- 2 x (1.5 ... 16) 2 x (2.5 ... 16)<br />

• With end sleeve<br />

mm2 -- 1 x (1.5 ... 25) 1 x (2.5 ... 50)<br />

• Stranded<br />

2<br />

mm -- 1 x (1.5 ... 35) 1 x (10 ... 70)<br />

• AWG cables<br />

- Solid or stranded<br />

AWG -- 1 x (16 ... 2) 2 x (10 ... 1/0)<br />

• Solid<br />

mm2 -- 2 x (1.5 ... 16) 2 x (2.5 ... 16)<br />

• With end sleeve<br />

mm2 -- 2 x (1.5 ... 16) 2 x (2.5 ... 35)<br />

• Stranded<br />

2<br />

mm -- 2 x (1.5 ... 25) 2 x (10 ... 50)<br />

• AWG cables<br />

- Solid or stranded<br />

AWG -- 2 x (16 ... 2) 1 x (10 ... 2/0)<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Spring-type terminals<br />

Busbar connections<br />

• Tightening torque<br />

NM 2 ... 2.5 4.5 6.5<br />

lb.in 18 ... 22 40 58<br />

Tools PZ 2 PZ 2 Allen screw 4 mm<br />

Degree of protection IP20 IP20<br />

(IP00 terminal<br />

compartment)<br />

Main conductors<br />

• Solid<br />

2<br />

mm 1 ... 10 --<br />

• Finely stranded with end sleeve mm 2 1 ... 6 end sleeves without<br />

--<br />

plastic collar<br />

• AWG cables<br />

- Solid or stranded (finely stranded) AWG 16 ... 10 --<br />

- Stranded<br />

AWG 1 x 8 --<br />

Tools DIN ISO 2380-1A0; 5 x 3 --<br />

Degree of protection IP20 --<br />

Main conductors<br />

• With cable lug acc. to DIN 46234 or max.<br />

20 mm wide<br />

- Stranded<br />

2<br />

mm<br />

Finely stranded<br />

mm<br />

IP20<br />

(IP00 terminal<br />

compartment)<br />

-- 2 x (10 ... 70)<br />

- 2 -- 2 x (10 ... 50)<br />

• AWG cables, solid or stranded AWG -- 2 x (7 ... 1/0)<br />

17-252<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW40 for standard applications<br />

Soft starters Type 3RW40 5. 3RW40 7.<br />

Conductor cross-sections<br />

Screw terminals<br />

Main conductors<br />

With box terminal 3RT19 55-4G (55 kW) 3RT19 66-4G<br />

Front clamping point • Finely stranded with end sleeve mm 2 16 ... 70 70 ... 240<br />

connected<br />

• Finely stranded without end sleeve mm 2 16 ... 70 70 ... 240<br />

2<br />

• Stranded<br />

mm 16 ... 70 95 ... 300<br />

• Ribbon cable conductors<br />

(number x width x thickness)<br />

mm Min. 3 x 9 x 0.8<br />

Max. 6 x 15.5 x 0.8<br />

Min. 6 x 9 x 0.8<br />

Max. 20 x 24 x 0.5<br />

• AWG cables, solid or stranded AWG 6 ... 2/0 3/0 ... 600 kcmil<br />

Rear clamping point<br />

connected<br />

• Finely stranded with end sleeve mm 2 16 ... 70 120 ... 185<br />

• Finely stranded without end sleeve mm 2 16 ... 70 120 ... 185<br />

2 • Stranded<br />

mm 16 ... 70 120 ... 240<br />

• Ribbon cable conductors<br />

(number x width x thickness)<br />

mm Min. 3 x 9 x 0.8<br />

Max. 6 x 15.5 x 0.8<br />

Min. 6 x 9 x 0.8<br />

Max. 20 x 24 x 0.5<br />

• AWG cables, solid or stranded AWG 6 ... 2/0 250 ... 500 kcmil<br />

Both clamping points • Finely stranded with end sleeve mm 2 Max. 1 x 50, 1 x 70 Min. 2 x 50; max. 2 x 185<br />

connected<br />

• Finely stranded without end sleeve mm 2 Max. 1 x 50, 1 x 70 Min. 2 x 50; max. 2 x 185<br />

2 • Stranded<br />

mm Max. 2 x 70 Max. 2 x 70; max. 2 x 240<br />

• Ribbon cable conductors<br />

mm Max. 2 x (6 x 15.5 x 0.8) Max. 2 x (20 x 24 x 0.5)<br />

(number x width x thickness)<br />

• AWG cables, solid or stranded AWG Max. 2 x 1/0 Min. 2 x 2/0 Max. 2 x 500 kcmil<br />

• Terminal screws M10 (hexagon socket, A/F4) M12 (hexagon socket, A/F5)<br />

- Tightening torque<br />

NM 10 ... 12 20 ... 22<br />

lb.in 90 ... 110 180 ... 195<br />

Screw terminals<br />

Main conductors<br />

With box terminal 3RT19 56-4G<br />

Front or rear clamping point • Finely stranded with end sleeve mm 2 16 ... 120<br />

connected<br />

• Finely stranded without end sleeve mm 2 16 ... 120<br />

2<br />

• Stranded<br />

mm 16 ... 120<br />

• Ribbon cable conductors<br />

(number x width x thickness)<br />

mm Min. 3 x 9 x 0.8<br />

Max. 6 x 15.5 x 0.8<br />

• AWG cables, solid or stranded AWG 6 ... 250 kcmil<br />

Soft Starter<br />

Control<br />

Both clamping points<br />

connected<br />

• Finely stranded with end sleeve mm 2 Max. 1 x 95, 1 x 120<br />

• Finely stranded without end sleeve 2 Max. 1 x 95, 1 x 120<br />

• Stranded<br />

mm2 Max. 2 x 120<br />

• Ribbon cable conductors<br />

mm Max. 2 x (10 x 15.5 x 0.8)<br />

(number x width x thickness)<br />

• AWG cables, solid or stranded AWG Max. 2 x 3/0<br />

Screw terminals<br />

Main conductors<br />

Without box terminal/busbar connection<br />

• Finely stranded with cable lug mm 2 16 ... 95 1) 50 ... 240 2)<br />

• Stranded with cable lug mm 2 25 ... 120 1) 70 ... 240 2)<br />

• AWG cables, solid or stranded AWG 4 ... 250 kcmil 2/0 ... 500 kcmil<br />

• Connecting bar (max. width) mm 17 25<br />

• Terminal screws M8 x 25 (A/F13) M10 x 30 (A/F17)<br />

- Tightening torque<br />

10 ... 14 14 ... 24<br />

1) When connecting cable lugs to DIN 46235, use 3RT19 56-4EA1 terminal cover for<br />

conductor cross-sections from 95 mm² to ensure phase spacing.<br />

NM<br />

lb.in 89 ... 124 124 ... 210<br />

2) When connecting cable lugs to DIN 46234, the 3RT19 66-4EA1 terminal cover<br />

must be used for cond. cross-sections of 240 mm² and more as well as DIN 46235<br />

for cond. cross-sections of 185 mm² and more to keep the phase clearance.<br />

17 CONTROL<br />

PRODUCTS<br />

Soft starters Type 3RW40 . .<br />

Conductor cross-sections<br />

Auxiliary conductors (1 or 2 conductors can be connected):<br />

Screw terminals<br />

• Solid<br />

mm2 2 x (0.5 ... 2.5)<br />

• Finely stranded with end sleeve mm 2 2 x (0.5 ... 1.5)<br />

• AWG cables<br />

- Solid or stranded<br />

AWG 2 x (20 ... 14)<br />

- Finely stranded with end sleeve AWG 2 x (20 ... 16)<br />

• Terminal screws<br />

- Tightening torque<br />

NM 0.8 ... 1.2<br />

lb.in 7 ... 10.3<br />

Spring-type terminals<br />

• Solid<br />

- 3RW40 2. ... 3RW40 4. mm 2 2 x (0.25 ... 2.5)<br />

- 3RW40 5., 3RW40 7. mm 2 2 x (0.25 ... 1.5)<br />

• Finely stranded with end sleeve mm 2 2 x (0.25 ... 1.5)<br />

• AWG cables, solid or stranded AWG 2 x (24 ... 14) for 3RW40 2. ... 3RW40 4.;<br />

2 x (24 ... 16) for 3RW40 5. and 3RW40 7.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-253


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Standard<br />

Parameters<br />

Electromagnetic compatibility<br />

acc. to EN 60947-4-2<br />

EMC interference immunity<br />

Electrostatic discharge (ESD) EN 61000-4-2 ±4 kV contact discharge, ±8 kV air discharge<br />

Electromagnetic RF fields EN 61000-4-3 Frequency range: 80 ... 1000 MHz with 80 % at 1 kHz<br />

Degree of severity 3: 10 V/m<br />

Conducted RF interference EN 61000-4-6 Frequency range: 150 kHz ... 80 MHz with 80 % at 1 kHz<br />

Interference 10 V<br />

RF voltages and RF currents on cables<br />

• Burst EN 61000-4-4 ±2 kV/5 kHz<br />

• Surge EN 61000-4-5 ±1 kV line to line<br />

±2 kV line to earth<br />

EMC interference emission<br />

EMC interference field strength EN 55011 Limit value of Class A at 30 ... 1000 MHz,<br />

limit value of Class B with 3RW40 2. 24 V AC/DC<br />

Radio interference voltage EN 55011 Limit value of Class A at 0.15 ... 30 MHz,<br />

limit value of Class B with 3RW40 2. 24 V AC/DC<br />

Radio interference suppression filters<br />

Degree of noise suppression A (industrial applications)<br />

Not required<br />

Degree of noise suppression B (applications for residential<br />

areas)<br />

Control voltage<br />

• 110 ... 230 V AC/DC Not available 1)<br />

• 115/230 V AC Not available 1)<br />

• 24 V AC/DC Not required for 3RW40 2.;<br />

required for 3RW40 3. and 3RW40 4. (see table)<br />

1) Degree of noise suppression B cannot be obtained through the use of filters<br />

as the strength of the electromagnetic field is not attenuated by the<br />

filter.<br />

Soft starter type Rated current Recommended filters 1)<br />

Soft starters Voltage range 200 ... 480 V<br />

Filter type Rated current filters Terminals<br />

A A mm 2<br />

3RW40 36 45 4EF1512-1AA10 50 16<br />

3RW40 37 63 4EF1512-2AA10 66 25<br />

3RW40 38 72 4EF1512-3AA10 90 25<br />

3RW40 46 80 4EF1512-3AA10 90 25<br />

3RW40 47 106 4EF1512-4AA10 120 50<br />

1) The radio interference suppression filter is used to remove the conducted<br />

interference from the main circuit. The field-related emissions comply with<br />

degree of noise suppression B. Filter selection applies under standard<br />

conditions: 10 starts per hour, start time 4 s at 300 % I e .<br />

Type Number Max. Fuse Class K5, RK5, RK1 Max. Fuse Class J Short Voltage Circuit Voltage<br />

Standard short circuit ratings 3RW40<br />

3RW40 24 50 A 60 A 5 kA 600 V<br />

3RW40 26 100 A 100 A 5 kA 600 V<br />

3RW40 27 125 A 125 A 5 kA 600 V<br />

3RW40 28 125 A 125 A 5 kA 600 V<br />

3RW40 36 175 A 175 A 10 kA 600 V<br />

3RW40 37 250 A 250 A 10 kA 600 V<br />

3RW40 38 250 A 250 A 10 kA 600 V<br />

3RW40 46 450 A 1) 300 A 10 kA 600 V<br />

3RW40 47 450 A 1) 350 A 10 kA 600 V<br />

1) Special purpose fuse Type 3N81333-2 manufactured by Siemens covered in File E167357.<br />

High capacity short circuit ratings 3RW40<br />

3RW40 24 50 A 50 A 42 kA 600 V<br />

3RW40 26 60 A 100 A 42 kA 600 V<br />

3RW40 27 60 A 125 A 42 kA 600 V<br />

3RW40 28 60 A 125 A 42 kA 600 V<br />

3RW40 36 100 A 175 A 30 kA 600 V<br />

3RW40 37 100 A 200 A 30 kA 600 V<br />

3RW40 38 100 A 200 A 30 kA 600 V<br />

3RW40 46 110 A 200 A 42 kA 600 V<br />

3RW40 47 110 A 200 A 42 kA 600 V<br />

For solid-state motor controller, Type 3RW402: Applicable in an enclosure with minimum overall dimensions of 370 by 190 by 190 mm.<br />

For solid-state motor controller, Type 3RW403: Applicable in an enclosure with minimum overall dimensions of 450 by 210 by 225 mm.<br />

For solid-state motor controller, Type 3RW404: Applicable in an enclosure with minimum overall dimensions of 450 by 220 by 235 mm.<br />

17-254<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW40 for standard applications<br />

Circuit Breaker SCCR<br />

Soft starters<br />

Q11<br />

Type<br />

ToC<br />

1<br />

Rated<br />

current<br />

Circuit Brakers<br />

Thermal Magnetic Instantaneous Trip Fuse<br />

480 V<br />

Type<br />

SCCR<br />

kA<br />

Max.<br />

size<br />

A<br />

600 V<br />

Type<br />

SCCR<br />

kA<br />

Max.<br />

size<br />

A<br />

480 V<br />

Type<br />

SCCR<br />

kA<br />

3RW40 24 11<br />

3RW40 26 23<br />

3RW40 27 29<br />

3RW40 28 34<br />

3RW40 36 42<br />

3RW40 37 58<br />

3RW40 38 62<br />

3RW40 46 73<br />

3RW40 47 98<br />

3RW40 55 117 FD63B 100 150 FD63B 50 150 FXD63A 100 150 FXD63A 50 150 RK5 100 200 J 100 400<br />

3RW40 56 145 JD63B 100 200 JD63B 50 250 FXD63A 100 250 FXD63A 50 250 RK5 100 250 J 100 500<br />

3RW40 73 205 JD63B 100 300 JD63B 50 300 JXD63A 100 300 JXD63A 50 300 RK5 100 250<br />

3RW40 74 248 JD63B 100 400 JD63B 50 400 JXD63A 100 400 JXD63A 50 400 RK5 100 450<br />

3RW40 75 315 LD63B 100 500 LD63B 50 450 JXD63A 100 400 JXD63A 50 400 RK5 100 600<br />

3RW40 76 385 LD63B 100 600 LD63B 50 600 LXD63H 100 600 LXD63H 50 600 L 100 700<br />

Fused version (line protection only)<br />

Max.<br />

size<br />

A<br />

600 V<br />

Type<br />

SCCR<br />

kA<br />

Max.<br />

size<br />

A<br />

600 V<br />

Type<br />

SCCR<br />

kA<br />

Max.<br />

size<br />

A<br />

600 V<br />

Type<br />

SCCR<br />

kA<br />

Max.<br />

size<br />

A<br />

Soft Starter<br />

Control<br />

F1<br />

Q21<br />

Q11<br />

M<br />

3~<br />

NSB0_01904<br />

Soft starters Line protection, maximum Line contactors<br />

Rated current Rated current Size (optional)<br />

ToC<br />

1<br />

Q11 F1 Q21<br />

Type A Type A<br />

Type of coordination "1" 1) : I q = 65 kA at 600 V +5 %<br />

3RW40 24 12.5 3NA3 820-6 50 00 3RT10 24<br />

3RW40 26 25 3NA3 822-6 63 00 3RT10 26<br />

3RW40 27 32 3NA3 824-6 80 00 3RT10 34<br />

3RW40 28 38 3NA3 824-6 80 00 3RT10 35<br />

3RW40 36 45 3NA3 130-6 100 1 3RT10 36<br />

3RW40 37 63 3NA3 132-6 125 1 3RT10 44<br />

3RW40 38 72 3NA3 132-6 125 1 3RT10 45<br />

3RW40 46 80 3NA3 136-6 160 1 3RT10 45<br />

3RW40 47 106 3NA3 136-6 160 1 3RT10 46<br />

3RW40 55 134 3NA3 244-6 250 2 3RT10 55-6A.36<br />

3RW40 56 162 3NA3 244-6 250 2 3RT10 56-6A.36<br />

3RW40 73 230 2 x 3NA3 354-6 2 x 355 3 3RT10 65-6A.36<br />

3RW40 74 280 2 x 3NA3 354-6 2 x 355 3 3RT10 66-6A.36<br />

3RW40 75 356 2 x 3NA3 365-6 2 x 500 3 3RT10 75-6A.36<br />

3RW40 76 432 2 x 3NA3 365-6 2 x 500 3 3RT10 76-6A.36<br />

1) The types of coordination are explained under "3RA1 Fuseless Load Feeders".<br />

The type of coordination "1" refers only to soft starters in combination<br />

with the stipulated protective device (motor starter protector/circuit<br />

breaker/fuse), not to any additional components in the feeder.<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-255


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW40 for standard applications<br />

Fused version with 3NE1 SITOR fuses (semiconductor and line protection)<br />

For matching fuse bases see Catalog LV 1 under "SENTRON Switching and Protection Devices for Power<br />

Distribution" ––> "Switch Disconnectors", and Catalog ET B1 under "BETA Protecting" ––> "SITOR<br />

F’1<br />

Semiconductor Fuses" or go to www.siemens.com/sitor ––>"Products" ––>"BETA Protecting"––>"SITOR"<br />

Q21<br />

Q11<br />

Soft Starter<br />

Control<br />

Soft<br />

starters<br />

ToC<br />

2<br />

Rated<br />

current<br />

M<br />

3~<br />

All-range fuses<br />

Rated current Size<br />

1) The types of coordination are explained in more detail under "3RA1 Fuseless<br />

Load Feeders".<br />

The type of coordination "2" refers only to soft starters in combination with<br />

the stipulated protective device (circuit breaker/fuse), not to any additional<br />

components in the feeder.<br />

NSB0_01905<br />

Line contactors<br />

(optional)<br />

Q11 F'1 Q21<br />

Type A Type A<br />

Type of coordination "2" 1) : I q = 65 kA at 600 V +5 %<br />

3RW40 24 12.5 3NE1 814-0 20 000 3RT10 24<br />

3RW40 26 25 3NE1 803-0 35 000 3RT10 26<br />

3RW40 27 32 3NE1 020-2 80 00 3RT10 34<br />

3RW40 28 38 3NE1 020-2 80 00 3RT10 35<br />

3RW40 36 45 3NE1 020-2 80 00 3RT10 36<br />

3RW40 37 63 3NE1 820-0 80 000 3RT10 44<br />

3RW40 38 72 3NE1 820-0 80 000 3RT10 45<br />

3RW40 46 80 3NE1 021-0 100 00 3RT10 45<br />

3RW40 47 106 3NE1 022-0 125 00 3RT10 46<br />

3RW40 55 134 3NE1 227-2 250 1 3RT10 55-6A.36<br />

3RW40 56 162 3NE1 227-2 250 1 3RT10 56-6A.36<br />

3RW40 73 230 3NE1 331-2 350 2 3RT10 65-6A.36<br />

3RW40 74 280 3NE1 333-2 450 2 3RT10 66-6A.36<br />

3RW40 75 356 3NE1 334-2 500 2 3RT10 75-6A.36<br />

3RW40 76 432 3NE1 435-2 560 3 3RT10 76-6A.36<br />

17<br />

CONTROL<br />

PRODUCTS<br />

ToC<br />

1<br />

ToC<br />

2<br />

Type of coordination "1"<br />

Type of coordination "2"<br />

The types of coordination are explained in more detail<br />

under "3RA1 Fuseless Load Feeders".<br />

These types of coordination are indicated in the<br />

Technical specifications by gray backgrounds.<br />

17-256<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW40 for standard applications<br />

Fused version with 3NE3 SITOR fuses (semiconductor protection by fuse, line and overload protection by motor starter protector;<br />

alternatively, installation with contactor and overload relay possible)<br />

For matching fuse bases see Catalog LV 1 under "SENTRON<br />

Switching and Protection Devices for Power Distribution" ––><br />

F3<br />

F1<br />

"Switch Disconnectors", and Catalog ET B1 under "BETA<br />

Q21<br />

Q1<br />

Protecting" ––> "SITOR Semiconductor Fuses" or go to<br />

F3<br />

rwww.siemens.com/sitor ––>"Products" ––>"BETA Protecting"<br />

Q11<br />

––>"SITOR"<br />

Q11<br />

M<br />

3~<br />

NSB0_01903<br />

Soft starters Semiconductor fuses, minimum Semiconductor fuses, maximum Semiconductor fuses, minimum<br />

Rated current Rated current Size Rated current Size Rated current Size<br />

ToC<br />

2<br />

Q11 F3 F3 F3<br />

Type A Type A Type A Type A<br />

Type of coordination "2" 1) : I q = 65 kA at 600 V +5 %<br />

3RW40 24 12.5 -- -- -- -- -- -- 3NE4 101 32 0<br />

3RW40 26 25 -- -- -- 3NE3 221 100 1 3NE4 102 40 0<br />

3RW40 27 32 -- -- -- 3NE3 224 160 1 3NE4 118 63 0<br />

3RW40 28 38 -- -- -- 3NE3 224 160 1 3NE4 118 63 0<br />

3RW40 36 45 -- -- -- 3NE3 224 160 1 3NE4 120 80 0<br />

3RW40 37 63 -- -- -- 3NE3 225 200 1 3NE4 121 100 0<br />

3RW40 38 72 3NE3 221 100 1 3NE3 227 250 1 -- -- --<br />

3RW40 46 80 3NE3 222 125 1 3NE3 225 200 1 -- -- --<br />

3RW40 47 106 3NE3 224 160 1 3NE3 231 350 1 -- -- --<br />

3RW40 55 134 3NE3 227 250 1 3NE3 335 560 2 -- -- --<br />

3RW40 56 162 3NE3 227 250 1 3NE3 335 560 2 -- -- --<br />

3RW40 73 230 3NE3 232-0B 400 1 3NE3 333 450 2 -- -- --<br />

3RW40 74 280 3NE3 233 450 1 3NE3 336 630 2 -- -- --<br />

3RW40 75 356 3NE3 335 560 2 3NE3 336 630 2 -- -- --<br />

3RW40 76 432 3NE3 337-8 710 2 3NE3 340-8 900 2 -- -- --<br />

Soft starters Semiconductor fuses max. Semiconductor fuses min. Semiconductor fuses max. Cylindrical fuses<br />

ToC<br />

2<br />

M<br />

3~<br />

NSB0_01906<br />

Rated current Rated current Size Rated current Size Rated current Size Rated<br />

current<br />

Q11 F3 F3 F3 F3<br />

Type A Type A Type A Type A Type A<br />

Type of coordination "2" 1) : I q = 65 kA at 600 V +5 %<br />

3RW40 24 12.5 3NE4 117 50 0 3NE8 015-1 25 00 3NE8 017-1 50 00 3NC2 240 40<br />

3RW40 26 25 3NE4 117 50 0 3NE8 017-1 50 00 3NE8 021-1 100 00 3NC2 263 63<br />

3RW40 27 32 3NE4 118 63 0 3NE8 018-1 63 00 3NE8 022-1 125 00 3NC2 280 80<br />

3RW40 28 38 3NE4 118 63 0 3NE8 020-1 80 00 3NE8 024-1 160 00 3NC2 280 80<br />

3RW40 36 45 3NE4 120 80 0 3NE8 020-1 80 00 3NE8 024-1 160 00 3NC2 280 80<br />

3RW40 37 63 3NE4 121 100 0 3NE8 021-1 100 00 3NE8 024-1 160 00 -- --<br />

3RW40 38 72 -- -- -- 3NE8 022-1 125 00 3NE8 024-1 160 00 -- --<br />

3RW40 46 80 -- -- -- 3NE8 022-1 125 00 3NE8 024-1 160 00 -- --<br />

3RW40 47 106 -- -- -- 3NE8 024-1 160 00 3NE8 024-1 160 00 -- --<br />

3RW40 55 134 -- -- -- -- -- -- -- -- -- -- --<br />

3RW40 56 162 -- -- -- -- -- -- -- -- -- -- --<br />

3RW40 73 230 -- -- -- -- -- -- -- -- -- -- --<br />

3RW40 74 280 -- -- -- -- -- -- -- -- -- -- --<br />

3RW40 75 356 -- -- -- -- -- -- -- -- -- -- --<br />

3RW40 76 432 -- -- -- -- -- -- -- -- -- -- --<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Soft starters Line contactors Motor starter protectors/circuit breakers Line protection, maximum<br />

Rated current (optional) 400 V +10 % Rated current 575 V +10 % Rated current Rated current Size<br />

ToC<br />

2<br />

Q11 Q21 Q1 Q1 F1<br />

Type A Type A Type A Type A<br />

Type of coordination "2" 1) : I q = 65 kA at 600 V +5 %<br />

3RW40 24 12.5 3RT10 24 3RV1 021-4KA10 55 -- -- 3NA3 820-6 50 00<br />

3RW40 26 25 3RT10 26 3RV1 021-4DA10 55 -- -- 3NA3 822-6 63 00<br />

3RW40 27 32 3RT10 34 3RV1 031-4EA10 55 -- -- 3NA3 824-6 80 00<br />

3RW40 28 38 3RT10 35 3RV1 031-4FA10 55 -- -- 3NA3 824-6 80 00<br />

3RW40 36 45 3RT10 36 3RV1 031-4GA10 20 -- -- 3NA3 130-6 100 1<br />

3RW40 37 63 3RT10 44 3RV1 041-4JA10 20 -- -- 3NA3 132-6 125 1<br />

3RW40 38 72 3RT10 45 3RV1 041-4KA10 20 -- -- 3NA3 132-6 125 1<br />

3RW40 46 80 3RT10 45 3RV1 041-4LA10 11 -- -- 3NA3 136-6 160 1<br />

3RW40 47 106 3RT10 46 3RV1 041-4MA10 11 -- -- 3NA3 136-6 160 1<br />

3RW40 55 134 3RT10 55-6A.36 3VL3 720 200 3VL3 720 200 3NA3 244-6 250 2<br />

3RW40 56 162 3RT10 56-6A.36 3VL3 720 200 3VL3 720 200 3NA3 244-6 250 2<br />

3RW40 73 230 3RT10 65-6A.36 3VL4 731 315 3VL5 731 315 2 x 3NA3 354-6 2 x 355 3<br />

3RW40 74 280 3RT10 66-6A.36 3VL4 731 315 3VL5 731 315 2 x 3NA3 354-6 2 x 355 3<br />

3RW40 75 356 3RT10 75-6A.36 3VL4 740 400 3VL5 740 400 2 x 3NA3 365-6 2 x 500 3<br />

3RW40 76 432 3RT10 76-6A.36 3VL5 750 500 3VL5 750 500 2 x 3NA3 365-6 2 x 500 3<br />

1) The types of coordination are explained under "3RA1 Fuseless Load Feeders".<br />

The type of coordination "2" refers only to soft starters in combination<br />

with the stipulated protective device (motor starter protector/circuit<br />

breaker/fuse), not to any additional components in the feeder.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-257


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW40 for standard applications<br />

Characteristic curves<br />

Motor protection tripping characteristics<br />

for 3RW40 (with symmetry)<br />

10 3<br />

[s]<br />

6<br />

NSB0_01488a<br />

Motor protection tripping characteristics<br />

for 3RW40 (with asymmetry)<br />

[s]<br />

10 3<br />

6<br />

NSB0_01705<br />

Tripping time<br />

4<br />

2<br />

Tripping Time<br />

4<br />

2<br />

10 2<br />

10 2<br />

6<br />

6<br />

4<br />

4<br />

Soft Starter<br />

Control<br />

2<br />

10 1<br />

1<br />

2 4 6 10<br />

x e<br />

Class 10 Class 15 Class 20<br />

2<br />

10 1<br />

0,1<br />

1,0 10<br />

x e<br />

Class 10 Class 15 Class 20<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Permissible installation height<br />

Operational rated current I in %<br />

e<br />

105<br />

100<br />

95<br />

90<br />

85<br />

80<br />

75<br />

70<br />

0 1000 2000 3000 4000 5000<br />

Mounting height in m<br />

At an installation height above 2000 m, the max. permissible operational<br />

voltage is reduced to 460 V.<br />

NSB0_01704<br />

17-258<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW40 for standard applications<br />

More information<br />

Application examples for normal starting (Class 10)<br />

Normal starting Class 10 (up to 20 s with 350 % I n motor ),<br />

The soft starter rating can be selected to be as high as the rating of the motor used.<br />

Application Conveyor belt Roller conveyor Small fan Pump Hydraulic pump<br />

Starting parameters<br />

• Voltage ramp and current<br />

limiting<br />

- Starting voltage % 70 60 40 40 40<br />

- Starting time s 10 10 10 10 10<br />

- Current limit value 5 x I M 5 x I M 4 x I M 4 x I M 4 x I M<br />

Ramp-down time s 5 5 0 10 0<br />

Application examples for heavy starting (Class 20)<br />

Heavy starting Class 20 (up to 40 s with 350 % I n motor ),<br />

The soft starter has to be selected at least one performance class higher than the motor used.<br />

Application Stirrer Compressor Centrifuge<br />

Starting parameters<br />

• Voltage ramp and current<br />

limiting<br />

- Starting voltage % 40 50 40<br />

- Starting time s 20 10 20<br />

- Current limit value 4 x I M 4 x I M 4 x I M<br />

Ramp-down time 0 0 0<br />

Soft Starter<br />

Control<br />

Note:<br />

These tables present sample set values and device sizes. They<br />

are intended only for the purposes of information and are not<br />

binding. The set values depend on the application in question<br />

and must be optimized during commissioning.<br />

The soft starter dimensions should be checked where necessary<br />

with the Win-Soft Starter software or with the help of Technical<br />

Assistance.<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-259


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW40 for standard applications<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Configuration<br />

The 3RW solid-state soft starters are designed for easy starting<br />

conditions. In the event of deviating conditions or increased<br />

switching frequency, it may be necessary to choose a larger device.<br />

For accurate dimensioning, use the Win-Soft Starter selection<br />

and simulation program.<br />

Where long starting times are involved, the integrated solid-state<br />

overload relay for heavy starting should not be disconnected.<br />

PTC sensors are recommended. This also applies for the smooth<br />

ramp-down because during the ramp-down time an additional<br />

current loading applies in contrast to free ramp-down.<br />

In the case of high switching frequencies in S4 mode, Siemens<br />

recommends the use of PTC sensors. For corresponding device<br />

versions with integrated thermistor motor protection or separate<br />

thermistor evaluation devices see Catalog LV 1.<br />

In the motor feeder between the SIRIUS 3RW soft starter and the<br />

motor, no capacitive elements are permitted (e. g. no reactivepower<br />

compensation equipment). In addition, neither static systems<br />

for reactive-power compensation nor dynamic PFC (Power<br />

Factor Correction) must be operated in parallel during starting<br />

and ramp-down of the soft starter. This is important to prevent<br />

faults arising on the compensation equipment and/or the soft<br />

starter.<br />

All elements of the main circuit (such as fuses and controls)<br />

should be dimensioned for direct starting, following the local<br />

short-circuit conditions. Fuses, controls and overload relays<br />

must be ordered separately. Please observe the maximum<br />

switching frequencies specified in the technical specifications.<br />

Note:<br />

When induction motors are switched on, voltage drops occur as<br />

a rule on starters of all types (direct starters, wye-delta starters,<br />

soft starters). The infeed transformer must always be dimensioned<br />

such that the voltage dip when starting the motor remains<br />

within the permissible tolerance. If the infeed transformer is dimensioned<br />

with only a small margin, it is best for the control voltage<br />

to be supplied from a separate circuit (independently of the<br />

main voltage) in order to avoid the potential switching off of the<br />

soft starter.<br />

Schematic circuit diagram<br />

L1 L2 L3<br />

T1 T2 T3<br />

A bypass contact system and solid-state overload relay are already<br />

integrated in the 3RW40 soft starter and therefore do not<br />

have to be ordered separately.<br />

NSB0_001485a<br />

Status graphs<br />

Win-Soft Starter selection and simulation program<br />

With this software, you can simulate and select all Siemens soft<br />

starters, taking into account various parameters such as mains<br />

properties, motor and load data, and special application<br />

requirements.<br />

The software is a valuable tool, which makes complicated,<br />

lengthy manual calculations for determining the required soft<br />

starters superfluous.<br />

The Win-Soft Starter selection and simulation program can be<br />

downloaded from:<br />

www.usa.siemens.com > Software<br />

More information can be found on the Internet at:<br />

www.usa.siemens.com.<br />

17-260<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

Overview<br />

In addition to soft starting and soft ramp-down, the solid-state<br />

SIRIUS 3RW44 soft starters provide numerous functions for<br />

higher-level requirements. They cover a performance range up<br />

to 900 Hp (at 460 V) in the inline circuit and up to 1600 Hp (at<br />

460 V) in the inside-delta circuit.<br />

The SIRIUS 3RW44 soft starters are characterized by a compact<br />

design for space-saving and clearly arranged control cabinet<br />

layouts. For optimized motor starting and stopping the innovative<br />

SIRIUS 3RW44 soft starters are an attractive alternative with<br />

considerable savings potential compared to applications with a<br />

frequency converter. The new torque control and adjustable current<br />

limiting enable the High-Feature soft starters to be used in<br />

nearly every conceivable task. They reliably mitagate the sudden<br />

torque applications and current peaks during motor starting<br />

and stopping. This creates savings potential when calculating<br />

the size of the controlgear and when servicing the machinery installed.<br />

Be it for inline circuits or inside-delta circuits – the<br />

SIRIUS 3RW44 soft starter offers savings especially in terms of<br />

size and equipment costs.<br />

The bypass contacts already integrated in the soft starter bypass<br />

the thyristors after a motor ramp-up is detected. This results<br />

in a further great reduction in the heat loss occuring during<br />

operation of the soft starter at rated value.<br />

Combinations of various starting, operating and ramp-down<br />

possibilities ensure an optimum adaptation to the applicationspecific<br />

requirements. Operation and commissioning can be<br />

performed with the menu-controlled keypad and a menuprompted,<br />

multi-line graphic display with background lighting.<br />

The optimized motor ramp-up and ramp-down can be effected<br />

quickly, easily and reliably by means of just a few settings with a<br />

previously selected language. Four-key operation and plain-text<br />

displays for each menu point guarantee full clarity at every moment<br />

of the parameterization and operation.<br />

Applicable standards<br />

• IEC 60947-4-2<br />

• UL/CSA<br />

Soft Starter ES parameterization software<br />

Soft Starter ES software is used for the parameterization, monitoring<br />

and service diagnostics of SIRIUS 3RW44 High Feature<br />

soft starters.<br />

See Catalog LV 1, Chapter 12 "Planning and Configuration with<br />

SIRIUS".<br />

Function<br />

Equipped with modern, ergonomic user prompting the<br />

SIRIUS 3RW44 soft starters can be commissioned quickly and<br />

easily using a keypad and a menu-prompted, multi-line graphic<br />

display with background lighting. The optimized motor ramp-up<br />

and ramp-down can be effected quickly, easily and reliably by<br />

means of just a few settings with a selectable language. Fourkey<br />

operation and plain-text displays for each menu point guarantee<br />

full clarity at every moment of the parameterization and<br />

operation. During operation and when control voltage is applied,<br />

the display field continuously presents measured values and operating<br />

values as well as warnings and fault messages. An external<br />

display and operator module can be connected by means<br />

of a connection cable to the soft starter, thus enabling active indications<br />

and the like to be read directly from the control cabinet<br />

door.<br />

The SIRIUS 3RW44 soft starters are equipped with optimum<br />

functionality. An integral bypass contact system reduces the<br />

power loss of the soft starter during operation.<br />

This reliably prevents heating of the switchgear environment.<br />

The SIRIUS 3RW44 soft starters have internal intrinsic device<br />

protection. This prevents thermal overloading of the power section's<br />

thyristors, e. g. due to unacceptably high closing<br />

operations.<br />

Wiring outlay for installing an additional motor overload relay is<br />

no longer needed as the SIRIUS 3RW44 soft starters perform<br />

this function too. In addition they offer adjustable trip classes<br />

and a thermistor motor protection function. As an option the thyristors<br />

can also be protected by SITOR semiconductor fuses<br />

from short-circuiting so that the soft starter is still functional after<br />

a short-circuit (type of coordination 2). And even inrush current<br />

peaks are reliably avoided thanks to adjustable current limiting.<br />

As a further option the SIRIUS 3RW44 soft starters can be upgraded<br />

with a PROFIBUS DP module. Thanks to their communication<br />

capability and their programmable control inputs and relay<br />

outputs the SIRIUS 3RW44 soft starters can be very easily<br />

and quickly integrated in higher-level controllers.<br />

In addition a creep speed function is available for positioning<br />

and setting jobs. With this function the motor can be controlled<br />

in both directions of rotation with reduced torque and an adjustable,<br />

low speed.<br />

On the other hand the SIRIUS 3RW44 soft starters offer a new,<br />

combined DC braking function for the fast stopping of driving<br />

loads.<br />

Highlights<br />

• Soft starting with breakaway pulse, torque control or voltage<br />

ramp, adjustable torque or current limiting as well as any combination<br />

of these, depending on load type<br />

• Integrated bypass contact system to minimize power loss<br />

• Various setting options for the starting parameters such as<br />

starting torque, starting voltage, ramp-up and ramp-down<br />

time, and much more in three separate parameter sets<br />

• Start-up detection<br />

• Inside-delta circuit for savings in terms of size and equipment<br />

costs<br />

• Various ramp-down modes selectable: free ramp-down,<br />

torque-controlled pump ramp-down, combined DC braking<br />

• Solid-state motor overload and intrinsic device protection<br />

• Thermistor motor protection<br />

• Keypad with a menu-prompted, multi-line graphic display with<br />

background lighting<br />

• Interface for communication with the PC for more accurate setting<br />

of the parameters as well as for control and monitoring<br />

• Simple adaptation to the motor feeder<br />

• Simple mounting and commissioning<br />

• Display of operating states and fault messages<br />

• Connection to PROFIBUS with optional PROFIBUS DP module<br />

• External display and operator module<br />

• Mains voltages from 200 to 690 V, 50 to 60 Hz<br />

• Applicable up to 60 °C (derating from 40 °C)<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-261


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

Type 3RW44 . .-.BC.4 3RW44 . .-.BC.5 3RW44 . .-.BC.6<br />

Power electronics<br />

Rated operational voltage for inline circuit V AC 200 ... 460 400 ... 600 400 ... 690<br />

Tolerance<br />

% -15/+10 -15/+10 -15/+10<br />

Maximum blocking voltage (thyristor) V AC 1400 1800 1800<br />

Rated operational voltage for inside-delta circuit V AC 200 ... 460 400 ... 600 400 ... 600<br />

Tolerance<br />

% -15/+10 -15/+10 -15/+10<br />

Rated frequency Hz 50 ... 60<br />

T olerance<br />

% ±10<br />

Uninterrupted duty at 40 °C (% of I e ) % 115<br />

Minimum load (% of set motor current I M ) % 8<br />

Maximum cable length between soft starter and motor m 500 1)<br />

Permissible installation height m 5000 (derating from 1000, see characteristic curves); higher on request<br />

Permissible mounting position<br />

Installation type<br />

Stand-alone installation<br />

Soft Starter<br />

Control<br />

Permissible ambient temperature<br />

Operation<br />

°C 0 ... +60; (derating from +40)<br />

Storage<br />

°C -25 ... +80<br />

Degree of protection<br />

IP00<br />

1) At the project configuration stage, it is important to make allowance for the<br />

voltage drop on the motor cable up to the motor connection. If necessary,<br />

higher values for the rated operational voltage or current must be calculated<br />

accordingly for the soft starter.<br />

Type 3RW44 22 3RW44 23 3RW44 24 3RW44 25 3RW44 26 3RW44 27<br />

Power electronics 40 °C/50 °C/60 °C<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Load rating with rated operational current I e<br />

• Acc. to IEC and UL/CSA 1) , for individual mounting at 40/50/60 °C, A 29/26/23 36/33/29 47/42/37 57/51/45 77/68/59 93/82/72<br />

AC-53a<br />

Smallest adjustable rated motor current I M<br />

A 5 7 9 11 15 18<br />

For the motor overload protection<br />

Power loss<br />

• In operation after completed starting with uninterrupted rated<br />

operational<br />

current (40 °C) approx.<br />

W 8 10 32 36 45 55<br />

• During starting with 300 % I M ( 40 °C)<br />

W 400 470 600 725 940 1160<br />

Permissible rated motor current and starts per hour<br />

• Normal starting (Class 5)<br />

2)<br />

- Rated motor current I M , starting time 5 s<br />

A 29/26/23 36/33/29 47/42/37 57/51/45 77/68/59 93/82/72<br />

- Starts per hour 3) 1/h 41 34 41 42 43 44<br />

- Rated motor current I<br />

2)4)<br />

M , starting time 10 s<br />

A 29/26/23 36/33/29 47/42/37 57/51/45 77/68/59 93/82/72<br />

- Starts per hour 3) 1/h 20 15 20 20 20 20<br />

• Normal starting (Class 10)<br />

- Rated motor current I<br />

2)<br />

M , starting time 10 s<br />

A 29/26/23 36/33/29 47/42/37 57/51/45 77/68/59 93/82/72<br />

- Starts per hour 3) 1/h 20 15 20 20 20 20<br />

- Rated motor current I<br />

2)4)<br />

M , starting time 20 s<br />

A 29/26/23 36/33/29 47/42/37 57/51/45 77/68/59 93/82/72<br />

- Starts per hour 3) 1/h 10 6 10 10 8 8<br />

• Normal starting (Class 15)<br />

- Rated motor current I<br />

2)<br />

M , starting time 15 s<br />

A 29/26/23 36/33/29 47/42/37 57/51/45 77/68/59 93/82/72<br />

- Starts per hour 3) 1/h 13 9 13 13 13 13<br />

2)4) - Rated motor current I M , starting time 30 s<br />

A 29/26/23 36/33/29 47/42/37 57/51/45 77/68/59 93/82/72<br />

- Starts per hour 3) 1/h 6 4 6 6 6 6<br />

• Normal starting (Class 20)<br />

2) - Rated motor current I M , starting time 20 s<br />

A 29/26/23 36/33/29 47/42/37 57/51/45 73/66/59 88/80/72<br />

- Starts per hour 3) 1/h 10 6 10 10 10 10<br />

2)4)<br />

- Rated motor current I M , starting time 30 s<br />

A 29/26/23 36/33/29 47/42/37 57/51/45 73/66/59 88/80/72<br />

- Starts per hour 3) 1/h 4 2 4 5 1.8 0.8<br />

• For very heavy starting (Class 30)<br />

2)<br />

- Rated motor current I M , starting time 30 s<br />

A 29/26/23 36/33/29 44/42/37 57/51/45 65/60/54 77/70/63<br />

- Starts per hour 3) 1/h 6 4 6 6 6 6<br />

- Rated motor current I<br />

2)3)<br />

M , starting time 60 s<br />

A 29/26/23 36/33/29 44/42/37 57/51/45 65/60/54 77/70/63<br />

- Starts per hour 3) 1/h 1.8 0.8 3.3 1.5 2 1<br />

1) Measurement at 60 °C according to UL/CSA not required.<br />

With 300 % I M .<br />

3) For intermittent duty S4 with ON period = 30 %, T u = 40 °C, stand-alone<br />

installation vertical. The quoted switching frequencies do not apply for<br />

automatic mode.<br />

4) Maximum adjustable rated motor current I M , dependent on CLASS setting.<br />

17-262<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

Type 3RW44 34 3RW44 35 3RW44 36<br />

Power electronics 40 °C/50 °C/60 °C<br />

Load rating with rated operational current I e<br />

• Acc. to IEC and UL/CSA 1) , for individual mounting at 40/50/60 °C, A 113/100/88 134/117/100 162/145/125<br />

AC-53a<br />

Smallest adjustable rated motor current I M<br />

A 22 26 32<br />

For the motor overload protection<br />

Power loss<br />

• In operation after completed starting with uninterrupted rated<br />

operational<br />

current (40 °C) approx.<br />

W 64 76 95<br />

• During starting with 300 % I M ( 40 °C)<br />

W 1350 1700 2460<br />

Permissible rated motor current and starts per hour<br />

• Normal starting (Class 5)<br />

2) - Rated motor current I M , starting time 5 s<br />

A 113/100/88 134/117/100 162/145/125<br />

- Starts per hour 3) 1/h 41 39 41<br />

2)4)<br />

- Rated motor current I M , starting time 10 s<br />

A 113/100/88 134/117/100 162/145/125<br />

- Starts per hour 3) 1/h 20 15 20<br />

• Normal starting (Class 10)<br />

2)<br />

- Rated motor current I M , starting time 10 s<br />

A 113/100/88 134/117/100 162/145/125<br />

- Starts per hour 3) 1/h 20 15 20<br />

- Rated motor current I<br />

2)4)<br />

M , starting time 20 s<br />

A 113/100/88 134/117/100 162/145/125<br />

- Starts per hour 3) 1/h 9 6 7<br />

• Normal starting (Class 15)<br />

2)<br />

- Rated motor current I M , starting time 15 s<br />

A 113/100/88 134/117/100 162/145/125<br />

- Starts per hour 3) 1/h 13 9 12<br />

- Rated motor current I<br />

2)4)<br />

M , starting time 30 s<br />

A 113/100/88 134/117/100 162/145/125<br />

- Starts per hour 3) 1/h 6 6 1<br />

• Normal starting (Class 20)<br />

- Rated motor current I<br />

2)<br />

M , starting time 20 s<br />

A 106/97/88 125/113/100 147/134/122<br />

- Starts per hour 3) 1/h 9 9 10<br />

2)4) - Rated motor current I M , starting time 30 s<br />

A 106/97/88 125/113/100 147/134/122<br />

- Starts per hour 3) 1/h 1.5 2 1<br />

• For very heavy starting (Class 30)<br />

2) - Rated motor current I M , starting time 30 s<br />

A 91/84/76 110/100/90 120/110/100<br />

- Starts per hour 3) 1/h 6 6 6<br />

2)4)<br />

- Rated motor current I M , starting time 60 s<br />

A 91/84/76 110/100/90 120/110/100<br />

- Starts per hour 3) 1/h 2 2 2<br />

1) Measurement at 60 °C according to UL/CSA not required.<br />

With 300 % I M .<br />

3) For intermittent duty S4 with ON period = 30 %, T u = 40 °C, stand-alone<br />

installation vertical. The quoted switching frequencies do not apply for<br />

automatic mode.<br />

4) Maximum adjustable rated motor current I M , dependent on CLASS setting.<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-263


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

Type 3RW44 43 3RW44 44 3RW44 45 3RW44 46 3RW44 47<br />

Power electronics 40 °C/50 °C/60 °C<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Soft Starter<br />

Control<br />

Load rating with rated operational current I e<br />

• Acc. to IEC and UL/CSA 1) , for individual mounting at 40/50/60 °C, A 203/180/156 250/215/185 313/280/250 356/315/280 432/385/335<br />

AC-53a<br />

Smallest adjustable rated motor current I M<br />

A 40 50 62 71 86<br />

For the motor overload protection<br />

Power loss<br />

• In operation after completed starting with uninterrupted rated<br />

operational<br />

current (40 °C) approx.<br />

W 89 110 145 174 232<br />

• During starting with 300 % I M ( 40 °C)<br />

W 3350 4000 4470 5350 5860<br />

Permissible rated motor current and starts per hour<br />

• Normal starting (Class 5)<br />

2) - Rated motor current I M , starting time 5 s<br />

A 203/180/156 250/215/185 313/280/250 356/315/280 432/385/335<br />

- Starts per hour 3) 1/h 41 41 41 41 39<br />

2)4)<br />

- Rated motor current I M , starting time 10 s<br />

A 203/180/156 250/215/185 313/280/250 356/315/280 432/385/335<br />

- Starts per hour 3) 1/h 20 20 19 17 16<br />

• Normal starting (Class 10)<br />

2)<br />

- Rated motor current I M , starting time 10 s<br />

A 203/180/156 250/215/185 313/280/250 356/315/280 432/385/335<br />

- Starts per hour 3) 1/h 20 20 19 17 16<br />

- Rated motor current I<br />

2)4)<br />

M , starting time 20 s<br />

A 203/180/156 250/215/185 313/280/250 356/315/280 432/385/335<br />

- Starts per hour 3) 1/h 9 10 6 4 5<br />

• Normal starting (Class 15)<br />

2)<br />

- Rated motor current I M , starting time 15 s<br />

A 203/180/156 240/215/185 313/280/250 325/295/265 402/385/335<br />

- Starts per hour 3) 1/h 13 13 10 13 11<br />

- Rated motor current I<br />

2)4)<br />

M , starting time 30 s<br />

A 203/180/156 240/215/185 313/280/250 325/295/265 402/385/335<br />

- Starts per hour 3) 1/h 3 6 1 2 1<br />

• Normal starting (Class 20)<br />

- Rated motor current I<br />

2)<br />

M , starting time 20 s<br />

A 195/175/155 215/195/180 275/243/221 285/263/240 356/326/295<br />

- Starts per hour 3) 1/h 10 10 10 10 10<br />

2)4) - Rated motor current I M , starting time 30 s<br />

A 195/175/155 215/195/180 275/243/221 285/263/240 356/326/295<br />

- Rtarts per hour 3) 1/h 1 5 1 3 1<br />

• For very heavy starting (Class 30)<br />

2) - Rated motor current I M , starting time 30 s<br />

A 162/148/134 180/165/150 220/201/182 240/223/202 285/260/235<br />

- Starts per hour 3) 1/h 6 6 6 6 6<br />

2)4)<br />

- Rated motor current I M , starting time 60 s<br />

A 162/148/134 180/165/150 220/201/182 240/223/202 285/260/235<br />

- Starts per hour 3) 1/h 3 3 3 2 1<br />

1) Measurement at 60 °C according to UL/CSA not required.<br />

2) With 300 % I M .<br />

3) For intermittent duty S4 with ON period = 30 %, T u = 40 °C, stand-alone<br />

installation vertical. The quoted switching frequencies do not apply for<br />

automatic mode.<br />

4) Maximum adjustable rated motor current I M , dependent on CLASS setting.<br />

17-264<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

Type 3RW44 53 3RW44 54 3RW44 55 3RW44 56 3RW44 57 3RW44 58<br />

Power electronics 40 °C/50 °C/60 °C<br />

Load rating with rated operational current I e<br />

• Acc. to IEC and UL/CSA 1) , for individual mounting at 40/50/60 °C, A 551/494/438 615/551/489 693/615/551 780/693/615 880/780/693 970/850/760<br />

AC-53a<br />

Smallest adjustable rated motor current I M<br />

A 110 123 138 156 176 194<br />

For the motor overload protection<br />

Power loss<br />

• In operation after completed starting with uninterrupted rated<br />

operational<br />

current (40 °C) approx.<br />

W 159 186 220 214 250 270<br />

• During starting with 300 % I M ( 40 °C)<br />

W 7020 8100 9500 11100 13100 15000<br />

Permissible rated motor current and starts per hour<br />

• Normal starting (Class 5)<br />

2) - Rated motor current I M , starting time 5 s<br />

A 551/494/438 615/551/489 693/615/551 780/693/615 880/780/693 970/850/760<br />

- Starts per hour 3) 1/h 41 41 37 33 22 17<br />

2)4)<br />

- Rated motor current I M , starting time 10 s<br />

A 551/494/438 615/551/489 693/615/551 780/693/615 880/780/693 970/850/760<br />

- Starts per hour 3) 1/h 20 20 16 13 8 5<br />

• Normal starting (Class 10)<br />

2)<br />

- Rated motor current I M , starting time 10 s<br />

A 551/494/438 615/551/489 693/615/551 780/693/615 880/780/693 970/850/760<br />

- Starts per hour 3) 1/h 20 20 16 13 8 5<br />

- Rated motor current I<br />

2)4)<br />

M , starting time 20 s<br />

A 551/494/438 615/551/489 693/615/551 780/693/615 880/780/693 970/850/760<br />

- Starts per hour 3) 1/h 10 9 6 4 0.3 0.3<br />

• Normal starting (Class 15)<br />

2)<br />

- Rated motor current I M , starting time 15 s<br />

A 551/494/438 615/551/489 666/615/551 723/693/615 780/710/650 821/755/693<br />

- Starts per hour 3) 1/h 13 13 11 9 8 8<br />

- Rated motor current I<br />

2)4)<br />

M , starting time 30 s<br />

A 551/494/438 615/551/489 666/615/551 723/693/615 780/710/650 821/755/693<br />

- Starts per hour 3) 1/h 6 4 3 1 0.4 0.5<br />

• Normal starting (Class 20)<br />

- Rated motor current I<br />

2)<br />

M , starting time 20 s<br />

A 551/494/438 591/551/489 633/615/551 670/634/576 710/650/590 740/685/630<br />

- Starts per hour 3) 1/h 10 10 7 8 8 9<br />

2)4) - Rated motor current I M , starting time 30 s<br />

A 551/494/438 591/551/489 633/615/551 670/634/576 710/650/590 740/685/630<br />

- Starts per hour 3) 1/h 4 2 1 1 0.4 1<br />

• For very heavy starting (Class 30)<br />

2) - Rated motor current I M , starting time 30 s<br />

A 500/480/438 525/489/455 551/520/480 575/540/490 600/550/500 630/580/530<br />

- Starts per hour 3) 1/h 6 6 6 6 6 6<br />

2)4)<br />

- Rated motor current I M , starting time 60 s<br />

A 500/480/438 525/489/455 551/520/480 575/540/490 600/550/500 630/580/530<br />

- Starts per hour 3) 1/h 2 1 1 1 1.5 1<br />

1) Measurement at 60 °C according to UL/CSA not required.<br />

With 300 % I M .<br />

3) For intermittent duty S4 with ON period = 30 %, T u = 40 °C, stand-alone<br />

installation vertical. The quoted switching frequencies do not apply for<br />

automatic mode.<br />

4) Maximum adjustable rated motor current I M , dependent on CLASS setting.<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-265


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

Type 3RW44 65 3RW44 66<br />

Power electronics 40 °C/50 °C/60 °C<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Soft Starter<br />

Control<br />

Load rating with rated operational current I e<br />

• Acc. to IEC and UL/CSA 1) , for individual mounting at 40/50/60 °C, A 1076/970/880 1214/1076/970<br />

AC-53a<br />

Smallest adjustable rated motor current I M<br />

A 215 242<br />

For the motor overload protection<br />

Power loss<br />

• In operation after completed starting with uninterrupted rated<br />

operational<br />

current (40 °C) approx.<br />

W 510 630<br />

• During starting with 300 % I M ( 40 °C)<br />

W 15000 17500<br />

Permissible rated motor current and starts per hour<br />

• Normal starting (Class 5)<br />

2) - Rated motor current I M , starting time 5 s<br />

A 1076/970/880 1214/1076/970<br />

- Starts per hour 3) 1/h 30 20<br />

2)4)<br />

- Rated motor current I M , starting time 10 s<br />

A 1076/970/880 1214/1076/970<br />

- Starts per hour 3) 1/h 10 6<br />

• Normal starting (Class 10)<br />

2)<br />

- Rated motor current I M , starting time 10 s<br />

A 1076/970/880 1214/1076/970<br />

- Starts per hour 3) 1/h 11 6<br />

- Rated motor current I<br />

2)4)<br />

M , starting time 20 s<br />

A 1076/970/880 1214/1076/970<br />

- Starts per hour 3) 1/h 3 0.5<br />

• Normal starting (Class 15)<br />

2)<br />

- Rated motor current I M , starting time 15 s<br />

A 1020/950/850 1090/1000/920<br />

- Starts per hour 3) 1/h 7 5<br />

- Rated motor current I<br />

2)4)<br />

M , starting time 30 s<br />

A 1020/950/850 1090/1000/920<br />

- Starts per hour 3) 1/h 1 1<br />

• Normal starting (Class 20)<br />

- Rated motor current I<br />

2)<br />

M , starting time 20 s<br />

A 970/880/810 1030/940/860<br />

- Starts per hour 3) 1/h 7 5<br />

2)4) - Rated motor current I M , starting time 30 s<br />

A 970/880/810 1030/940/860<br />

- Starts per hour 3) 1/h 1 1<br />

• For very heavy starting (Class 30)<br />

2) - Rated motor current I M , starting time 30 s<br />

A 880/810/740 920/850/780<br />

- Starts per hour 3) 1/h 6 6<br />

2)4)<br />

- Rated motor current I M , starting time 60 s<br />

A 880/810/740 920/850/780<br />

- Starts per hour 3) 1/h 1 1<br />

1) Measurement at 60 °C according to UL/CSA not required.<br />

2) With 300 % I M .<br />

3) For intermittent duty S4 with ON period = 30 %, T u = 40 °C, stand-alone<br />

installation vertical. The quoted switching frequencies do not apply for<br />

automatic mode.<br />

4) Maximum adjustable rated motor current I M , dependent on CLASS setting.<br />

17-266<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

3RW44 27-1BC44 3RW44 36-6BC44 3RW44 47-6BC44 3RW44 58-6BC44 3RW44 66-6BC44<br />

Ambient temperature 40 °C Ambient temperature 50 °C DT Order No. List<br />

Rated<br />

operational<br />

current<br />

I e<br />

1)<br />

Rated power of induction motors for Rated Rated power of induction<br />

rated operational voltage U e operational<br />

motors for rated operational<br />

voltage U e<br />

current<br />

I e<br />

230 V 400 V 500 V 690 V 1000 V 200 V 230 V 460 V 575 V<br />

Price $<br />

per PU<br />

1864 630 1100 -- -- -- 1680 650 750 1500 -- C 3RW44 65-@BC@4 1 1 unit 131 78.000<br />

2103 710 1200 -- -- -- 1864 700 850 1700 -- C 3RW44 66-@BC@4 1 1 unit 131 78.000<br />

Order No. supplement for connection types<br />

• With spring-type terminals 2<br />

• With screw terminals 6<br />

3)<br />

Order No. supplement for the rated control supply voltage U s<br />

• 115 V AC 3<br />

• 230 V AC 4<br />

1) In the selection table, the unit rated current I e refers to the induction<br />

motor's rated operational current in the inside-delta circuit.<br />

The actual current of the device is approx. 58 % of this value.<br />

2) 3RW44 2. ... 3RW44 4. soft starters with screw terminals:<br />

delivery times } (preferred type),<br />

PU<br />

(UNIT,<br />

SET,<br />

M)<br />

PS* PG Weight<br />

per PU<br />

approx.<br />

A kW kW kW kW kW A hp hp hp hp kg<br />

Inside-delta circuits, rated operational voltage 200 ... 460 V 2)<br />

50 15 22 -- -- -- 45 10 15 30 -- } 3RW44 22-@BC@4 1 1 unit 131 6.500<br />

62 18.5 30 -- -- -- 55 15 20 40 -- } 3RW44 23-@BC@4 1 1 unit 131 6.500<br />

81 22 45 -- -- -- 73 20 25 50 -- } 3RW44 24-@BC@4 1 1 unit 131 6.500<br />

99 30 55 -- -- -- 88 25 30 60 -- } 3RW44 25-@BC@4 1 1 unit 131 6.500<br />

133 37 75 -- -- -- 118 30 40 75 -- } 3RW44 26-@BC@4 1 1 unit 131 6.500<br />

161 45 90 -- -- -- 142 40 50 100 -- } 3RW44 27-@BC@4 1 1 unit 131 6.500<br />

Order No. supplement for connection types<br />

• With spring-type terminals 3<br />

• With screw terminals 1<br />

196 55 110 -- -- -- 173 50 60 125 -- B 3RW44 34-@BC@4 1 1 unit 131 7.900<br />

232 75 132 -- -- -- 203 60 75 150 -- B 3RW44 35-@BC@4 1 1 unit 131 7.900<br />

281 90 160 -- -- -- 251 75 100 200 -- B 3RW44 36-@BC@4 1 1 unit 131 7.900<br />

352 110 200 -- -- -- 312 100 125 250 -- B 3RW44 43-@BC@4 1 1 unit 131 11.500<br />

433 132 250 -- -- -- 372 125 150 300 -- B 3RW44 44-@BC@4 1 1 unit 131 11.500<br />

542 160 315 -- -- -- 485 150 200 400 -- B 3RW44 45-@BC@4 1 1 unit 131 11.500<br />

617 200 355 -- -- -- 546 150 200 450 -- B 3RW44 46-@BC@4 1 1 unit 131 11.500<br />

748 250 400 -- -- -- 667 200 250 600 -- B 3RW44 47-@BC@4 1 1 unit 131 11.500<br />

954 315 560 -- -- -- 856 300 350 750 -- C 3RW44 53-@BC@4 1 1 unit 131 50.000<br />

1065 355 630 -- -- -- 954 350 400 850 -- C 3RW44 54-@BC@4 1 1 unit 131 50.000<br />

1200 400 710 -- -- -- 1065 350 450 950 -- C 3RW44 55-@BC@4 1 1 unit 131 50.000<br />

1351 450 800 -- -- -- 1200 450 500 1050 -- C 3RW44 56-@BC@4 1 1 unit 131 50.000<br />

1524 500 900 -- -- -- 1351 450 600 1200 -- C 3RW44 57-@BC@4 1 1 unit 131 50.000<br />

1680 560 1000 -- -- -- 1472 550 650 1300 -- C 3RW44 58-@BC@4 1 1 unit 131 50.000<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

3) Control by way of the internal 24 V DC supply and direct control by means<br />

of PLC possible.<br />

Note:<br />

Soft starter selection depends on the rated motor current.<br />

The 3RW44 solid-state soft starters are designed for normal<br />

starting (Class 10). (Inertia load of the overall operating mechanism<br />

J Load 40 °C and switching<br />

frequency.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-267


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Ambient temperature 40 °C Ambient temperature 50 °C DT Order No. List<br />

Rated<br />

operational<br />

current<br />

I e<br />

1)<br />

Rated power of induction motors for Rated Rated power of induction<br />

rated operational voltage U e operational<br />

motors for rated operational<br />

voltage U e<br />

current<br />

I e<br />

230 V 400 V 500 V 690 V 1000 V 200 V 230 V 460 V 575 V<br />

1) In the selection table, the unit rated current I e refers to the induction<br />

motor's rated operational current in the inside-delta circuit.<br />

The actual current of the device is approx. 58 % of this value.<br />

2) Soft starter with screw terminals:<br />

3RW44 2. ... 3RW44 4. Delivery time A<br />

3RW44 5. ... 3RW44 6. Delivery time B.<br />

3) Control by way of the internal 24 V DC supply and direct control by means<br />

of PLC possible.<br />

Note:<br />

Soft starter selection depends on the rated motor current.<br />

The 3RW44 solid-state soft starters are designed for normal<br />

starting (Class 10). (Inertia load of the overall operating mechanism<br />

J Load 40 °C and switching<br />

frequency.<br />

Price $<br />

per PU<br />

PU<br />

(UNIT,<br />

SET,<br />

M)<br />

PS* PG Weight<br />

per PU<br />

approx.<br />

A kW kW kW kW kW A hp hp hp hp kg<br />

Inside-delta circuits, rated operational voltage 400 ... 600 V 2)<br />

50 -- 22 30 -- -- 45 -- -- 30 40 A 3RW44 22-@BC@5 1 1 unit 131 6.500<br />

62 -- 30 37 -- -- 55 -- -- 40 50 A 3RW44 23-@BC@5 1 1 unit 131 6.500<br />

81 -- 45 45 -- -- 73 -- -- 50 60 A 3RW44 24-@BC@5 1 1 unit 131 6.500<br />

99 -- 55 55 -- -- 88 -- -- 60 75 A 3RW44 25-@BC@5 1 1 unit 131 6.500<br />

133 -- 75 90 -- -- 118 -- -- 75 100 A 3RW44 26-@BC@5 1 1 unit 131 6.500<br />

161 -- 90 110 -- -- 142 -- -- 100 125 A 3RW44 27-@BC@5 1 1 unit 131 6.500<br />

Order No. supplement for connection types<br />

• With spring-type terminals 3<br />

• With screw terminals 1<br />

196 -- 110 132 -- -- 173 -- -- 125 150 B 3RW44 34-@BC@5 1 1 unit 131 7.900<br />

232 -- 132 160 -- -- 203 -- -- 150 200 B 3RW44 35-@BC@5 1 1 unit 131 7.900<br />

281 -- 160 200 -- -- 251 -- -- 200 250 B 3RW44 36-@BC@5 1 1 unit 131 7.900<br />

352 -- 200 250 -- -- 312 -- -- 250 300 B 3RW44 43-@BC@5 1 1 unit 131 11.500<br />

433 -- 250 315 -- -- 372 -- -- 300 350 B 3RW44 44-@BC@5 1 1 unit 131 11.500<br />

542 -- 315 355 -- -- 485 -- -- 400 500 B 3RW44 45-@BC@5 1 1 unit 131 11.500<br />

617 -- 355 450 -- -- 546 -- -- 450 600 B 3RW44 46-@BC@5 1 1 unit 131 11.500<br />

748 -- 400 500 -- -- 667 -- -- 600 750 B 3RW44 47-@BC@5 1 1 unit 131 11.500<br />

954 -- 560 630 -- -- 856 -- -- 750 950 C 3RW44 53-@BC@5 1 1 unit 131 50.000<br />

1065 -- 630 710 -- -- 954 -- -- 850 1050 C 3RW44 54-@BC@5 1 1 unit 131 50.000<br />

1200 -- 710 800 -- -- 1065 -- -- 950 1200 C 3RW44 55-@BC@5 1 1 unit 131 50.000<br />

1351 -- 800 900 -- -- 1200 -- -- 1050 1350 C 3RW44 56-@BC@5 1 1 unit 131 50.000<br />

1524 -- 900 1000 -- -- 1351 -- -- 1200 1500 C 3RW44 57-@BC@5 1 1 unit 131 50.000<br />

1680 -- 1000 1200 -- -- 1472 -- -- 1300 1650 C 3RW44 58-@BC@5 1 1 unit 131 50.000<br />

1864 -- 1100 1350 -- -- 1680 -- -- 1500 1900 C 3RW44 65-@BC@5 1 1 unit 131 78.000<br />

2103 -- 1200 1500 -- -- 1864 -- -- 1700 2100 C 3RW44 66-@BC@5 1 1 unit 131 78.000<br />

Order No. supplement for connection types<br />

• With spring-type terminals 2<br />

• With screw terminals 6<br />

3)<br />

Order No. supplement for the rated control supply voltage U s<br />

• 115 V AC 3<br />

• 230 V AC 4<br />

17-268<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

Technical specifications<br />

Type 3RW44 . .-.BC3. 3RW44 . .-.BC4.<br />

Terminal<br />

Control electronics<br />

Rated values<br />

Rated control supply voltage<br />

A1/A2/PE V 115 AC 230 AC<br />

• Tolerance<br />

% -15/+10 -15/+10<br />

Rated control supply current STANDBY<br />

mA 30 20<br />

Rated control supply current ON<br />

• 3RW44 2.<br />

mA 300 170<br />

• 3RW44 3.<br />

mA 500 250<br />

• 3RW44 4.<br />

mA 750 400<br />

• 3RW44 5.<br />

mA 450 200<br />

• 3RW44 6.<br />

mA 650 300<br />

Maximum current (pickup bypass)<br />

• 3RW44 2.<br />

mA 1000 500<br />

• 3RW44 3.<br />

mA 2500 1250<br />

• 3RW44 4.<br />

mA 6000 3000<br />

• 3RW44 5.<br />

mA 4500 2500<br />

• 3RW44 6.<br />

mA 4500 2500<br />

Rated frequency<br />

Hz 50 ... 60 50 ... 60<br />

• Tolerance<br />

% ±10 ±10<br />

Type 3RW44. .<br />

Terminal<br />

Factory default<br />

Control electronics<br />

Control inputs<br />

Input<br />

1<br />

IN1<br />

Start motor right parameter set 1<br />

Input<br />

2<br />

IN2<br />

No action<br />

Input<br />

3<br />

IN3<br />

No action<br />

Input<br />

4<br />

IN4<br />

Trip reset<br />

Supply<br />

L+/L-<br />

• Rated operational current<br />

mA Approx. 10 per input to DIN 19240<br />

• Rated operational voltage<br />

L+<br />

Internal voltage: 24 V DC from internal<br />

supply through terminal L+ to<br />

IN1 ... IN4. Maximum load at L+<br />

approx. 55 mA<br />

L- External voltage: DC external voltage<br />

(acc. to DIN 19240) through terminals<br />

L- and IN1 ... IN4<br />

(min. 12 V DC, max. 30 V DC)<br />

Thermistor motor protection input<br />

Input<br />

T1/T2<br />

PTC type A or Thermoclick Deactivated<br />

Relay outputs (floating auxiliary contacts)<br />

Output<br />

1<br />

13/14<br />

ON period<br />

Output<br />

2<br />

23/24<br />

No action<br />

Output<br />

3<br />

33/34<br />

No action<br />

Output<br />

4<br />

95/96/98<br />

Group fault<br />

Switching capacity of the relay outputs (auxiliary contacts)<br />

230<br />

V/AC-15<br />

A 3 at 240 V<br />

24 V/DC-13<br />

A 1 at 24 V<br />

Protection against overvoltages<br />

Short-circuit protection<br />

Protection by means of varistor through relay contact<br />

4 A gL/gG operational class;<br />

6 A quick (fuse is not included in scope of supply)<br />

Protection functions<br />

Motor protection functions<br />

Trips in the event of<br />

Thermal overloading of the motor<br />

Trip class acc. to IEC 60947-4-1<br />

Class<br />

5/10/15/20/30 10<br />

P hase failure sensitivity<br />

% >40<br />

Overload warning<br />

Yes<br />

Reset and recovery Manual/Automatic Manual<br />

Reset option after tripping Manual/Automatic Manual<br />

Recovery<br />

time<br />

min. 1 ... 30 1<br />

Device protection functions<br />

Trips in the event of<br />

Thermal overloading of the thyristors<br />

Reset option after tripping Manual/Automatic Manual<br />

Recovery<br />

time<br />

min. 0.5<br />

Bypass protection functions<br />

Trips in the event of<br />

Thermal overloading of the bypass<br />

contacts<br />

Reset option after tripping<br />

Manual<br />

Recovery<br />

time<br />

min. 1<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-269


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Type 3RW44. .<br />

Factory default<br />

Control times and parameters<br />

Control times<br />

C losing time (with connected control voltage)<br />

ms


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

Type 3RW44 . .<br />

Factory default<br />

Control times and parameters<br />

Warnings/error signals (continued)<br />

Temperature sensor<br />

• Overload<br />

• Open circuit<br />

• Short-circuit<br />

Ground fault<br />

• Detected<br />

Connection abort in manual operating mode<br />

Max. number of starts exceeded<br />

I e limit value overshoot/undershoot<br />

Heat sink sensor<br />

• Open circuit<br />

• Short-circuit<br />

Quick-stop active<br />

Switching block defective<br />

I e /class setting not permissible<br />

No external start-up parameters received<br />

PAA fault<br />

Control inputs<br />

Input 1 Motor right parameter set 1<br />

Input 2<br />

No action<br />

Input 3<br />

No action<br />

Input 4<br />

Trip reset<br />

Parameterizing options for control inputs 1 ... 4<br />

No action<br />

Local manual mode<br />

Emergency start<br />

Creep speed<br />

Quick-stop<br />

Trip reset<br />

Motor right parameter set 1<br />

Motor left parameter set 1 1)<br />

Motor right parameter set 2<br />

Motor left parameter set 2 1)<br />

Motor right parameter set 3<br />

Motor left parameter set 3 1)<br />

Relay outputs<br />

Output 1<br />

ON period<br />

Output 2<br />

No action<br />

Output 3<br />

No action<br />

Output 4<br />

Group fault<br />

Parameterizing options for relay outputs 1 ... 3<br />

No action<br />

PAA output 1<br />

PAA output 2<br />

Input 1<br />

Input 2<br />

Input 3<br />

Input 4<br />

Starting<br />

Operation/Bypass<br />

Ramp-down<br />

ON period<br />

Command motor on<br />

DC braking contactor<br />

Group warning<br />

Group fault<br />

Bus fault<br />

Device fault<br />

Power on<br />

Ready to start<br />

Motor temperature sensor<br />

Deactivated<br />

Thermoclick<br />

PTC type A<br />

1) Parameter motor left possible only in conjunction with creep mode.<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-271


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

Type 3RW44 2. 3RW44 3. 3RW44 4. 3RW44 5.<br />

3RW44 6.<br />

Conductor cross-sections<br />

Screw terminals Main conductors<br />

With box terminal 3RT19 55-4G 3RT19 66-4G --<br />

(55 kW)<br />

Front clamping • Finely stranded with end sleeve mm 2 2.5 ... 35 16 ... 70 70 ... 240 --<br />

point connected • Finely stranded without end sleeve mm 2 4 ... 50 16 ... 70 70 ... 240 --<br />

2<br />

• Solid<br />

mm 2.5 ... 16 -- -- --<br />

• Stranded<br />

2 mm 4 ... 70 16 ... 70 95 ... 300 --<br />

• Ribbon cable conductors<br />

mm 6 x 9 x 0.8 Min. 3 x 9 x 0.8 Min. 6 x 9 x 0.8 --<br />

(number x width x thickness)<br />

Max. 6 x 15.5 x 0.8 Max. 20 x 24 x 0.5<br />

• AWG cables, solid or stranded AWG 10 ... 2/0 6 ... 2/0 3/0 ... 600 kcmil --<br />

Rear clamping point<br />

connected<br />

• Finely stranded with end sleeve mm 2 2.5 ... 50 16 ... 70 120 ... 185 --<br />

• Finely stranded without end sleeve mm 2 10 ... 50 16 ... 70 120 ... 185 --<br />

2 • Solid<br />

mm 2.5 ... 16 -- -- --<br />

2 • Stranded<br />

mm 10 ... 70 16 ... 70 120 ... 240 --<br />

• Ribbon cable conductors<br />

mm 6 x 9 x 0.8 Min. 3 x 9 x 0.8 Min. 6 x 9 x 0.8 --<br />

(number x width x thickness)<br />

Max. 6 x 15.5 x 0.8 Max. 20 x 24 x 0.5<br />

• AWG cables, solid or stranded AWG 10 ... 2/0 6 ... 2/0 250 ... 500 kcmil --<br />

Soft Starter<br />

Control<br />

17<br />

Both clamping • Finely stranded with end sleeve mm 2 2 x (2.5 ... 35) Max. 1 x 50, 1 x 70 Min. 2 x 50 --<br />

points connected<br />

Max. 2 x 185<br />

• Finely stranded without end sleeve mm 2 2 x (4 ... 35) Max. 1 x 50, 1 x 70 Min. 2 x 50 --<br />

Max. 2 x 185<br />

• Solid<br />

2<br />

mm 2 x (2.5 ... 16) -- -- --<br />

• Stranded<br />

2 mm 2 x (4 ... 50) Max. 2 x 70 Max. 2 x 70 --<br />

Max. 2 x 240<br />

• Ribbon cable conductors<br />

mm 2 x (6 x 9 x 0.8) Max. 2 x<br />

Max. 2 x<br />

--<br />

(number x width x thickness)<br />

(6 x 15.5 x 0.8) (20 x 24 x 0.5)<br />

• AWG cables, solid or stranded AWG 2 x (10 ... 1/0) Max. 2 x 1/0 Min. 2 x 2/0 --<br />

Max. 2 x 500 kcmil<br />

• Terminal screws<br />

M6 (hexagon M10 (hexagon M12 (hexagon --<br />

socket, A/F4) socket, A/F4) socket, A/F5)<br />

- Tightening torque<br />

NM 4 ... 6 10 ... 12 20 ... 22 --<br />

lb.in 36 ... 53 90 ... 110 180 ... 195 --<br />

Screw terminals Main conductors<br />

With box terminal -- 3RT19 56-4G -- --<br />

Front or rear clamping<br />

• Finely stranded with end sleeve mm 2 -- 16 ... 120 -- --<br />

point connected • Finely stranded without end sleeve mm 2 -- 16 ... 120 -- --<br />

2 • Stranded<br />

mm -- 16 ... 120 -- --<br />

• Ribbon cable conductors<br />

mm -- Min. 3 x 9 x 0.8 -- --<br />

(number x width x thickness)<br />

Max. 6 x 15.5 x 0.8<br />

• AWG cables, solid or stranded AWG -- 6 ... 250 kcmil -- --<br />

CONTROL<br />

PRODUCTS<br />

Both clamping<br />

points connected<br />

• Finely stranded with end sleeve mm 2 -- Max. 1 x 95, -- --<br />

1 x 120<br />

• Finely stranded without end sleeve mm 2 -- Max. 1 x 95, -- --<br />

1 x 120<br />

• Stranded<br />

2<br />

mm -- Max. 2 x 120 -- --<br />

• Ribbon cable conductors<br />

mm -- Max. 2 x<br />

-- --<br />

(number x width x thickness)<br />

(10 x 15.5 x 0.8)<br />

• AWG cables, solid or stranded AWG -- Max. 2 x 3/0 -- --<br />

Screw terminals<br />

Main conductors<br />

Without box terminal/busbar connection<br />

• Finely stranded with cable lug mm 2 -- 16 ... 95 1) 50 ... 240 2) 50 ... 240 2)<br />

• Stranded with cable lug mm 2 -- 25 ... 120 1) 70 ... 240 2) 70 ... 240 2)<br />

• AWG cables, solid or stranded AWG -- 4 ... 250 kcmil 2/0 ... 500 kcmil 2/0 ... 500 kcmil<br />

• Connecting bar (max. width) mm -- 17 25 60<br />

• Terminal screws -- M8 x 25 (A/F13) M10 x 30 (A/F17) M12 x 40<br />

- Tightening torque<br />

NM -- 10 ... 14 14 ... 24 20 ... 35<br />

lb.in -- 89 ... 124 124 ... 210 177 ... 310<br />

1) When connecting cable lugs to DIN 46235, use 3RT19 56-4EA1 terminal<br />

cover for conductor cross-sections from 95 mm² to ensure phase spacing.<br />

2) When connecting cable lugs to DIN 46234, the 3RT19 66-4EA1 terminal<br />

cover must be used for conductor cross-sections of 240 mm² and more as<br />

well as DIN 46235 for conductor cross-sections of 185 mm² and more to<br />

keep the phase clearance.<br />

17-272<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

Soft starters Type 3RW44. .<br />

Conductor cross-sections<br />

Auxiliary conductors (1 or 2 conductors can be connected):<br />

Screw terminals<br />

• Solid<br />

2 mm 2 x (0.5 ... 2.5)<br />

• Finely stranded with end sleeve mm 2 2 x (0.5 ... 1.5)<br />

• AWG cables<br />

- Solid or stranded<br />

AWG 2 x (20 ... 14)<br />

- Finely stranded with end sleeve AWG 2 x (20 ... 16)<br />

• Terminal screws<br />

- Tightening torque<br />

NM 0.8 ... 1.2<br />

lb.in 7 ... 10.3<br />

Spring-type terminals<br />

• Solid<br />

mm2 2 x (0.25 ... 1.5)<br />

• Finely stranded with end sleeve mm 2 2 x (0.25 ... 1.5)<br />

• AWG cables, solid or stranded AWG 2 x (24 ... 16)<br />

Electromagnetic compatibility acc. to EN 60947-4-2<br />

EMC interference immunity<br />

Electrostatic discharge (ESD)<br />

Electromagnetic RF fields<br />

Conducted RF interference<br />

RF voltages and RF currents on cables<br />

• Burst<br />

• Surge<br />

Standard<br />

Parameters<br />

EN 61000-4-2 ±4 kV contact discharge, ±8 kV air discharge<br />

EN 61000-4-3 Frequency range: 80 ... 1000 MHz with 80 % at 1 kHz<br />

Degree of severity 3, 10 V/m<br />

EN 61000-4-6 Frequency range: 150 kHz ... 80 MHz with 80 % at 1 kHz<br />

Interference 10 V<br />

EN 61000-4-4 ±2 kV/5 kHz<br />

EN 61000-4-5 ±1 kV line to line<br />

±2 kV line to ground<br />

EMC interference emission<br />

EMC interference field strength EN 55011 Limit value of Class A at 30 ... 1000 MHz<br />

Radio interference voltage EN 55011 Limit value of Class A at 0.15 ... 30 MHz<br />

Is an RI suppression filter necessary?<br />

Degree of noise suppression A (industrial applications)<br />

No<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-273


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

Circuit Breaker SCCR<br />

Soft Starter<br />

Control<br />

Soft starters<br />

Q11<br />

Type<br />

ToC<br />

1<br />

Rated<br />

current<br />

Circuit Brakers<br />

Thermal Magnetic Instantaneous Trip Fuse<br />

480 V<br />

Type<br />

SCCR<br />

kA<br />

Max.<br />

size<br />

A<br />

600 V<br />

Type<br />

SCCR<br />

kA<br />

Max.<br />

size<br />

A<br />

480 V<br />

Type<br />

SCCR<br />

kA<br />

3RW44 22 11 ED63B, 100 40 ED63A, 100 40 ED63A, 50 40 RK5 100 50 J 100 100<br />

HEG3G<br />

HEM3M<br />

HEM3M<br />

3RW44 23 23 ED63B, 100 50 ED63A, 100 50 ED63A, 50 50 RK5 100 60 J 100 120<br />

HEG3G<br />

HEM3M<br />

HEM3M<br />

3RW44 24 29 ED63B, 100 70 ED63A, 100 100 ED63A, 50 50 RK5 100 80 J 100 160<br />

HEG3G<br />

HEM3M<br />

HEM3M<br />

3RW44 25 29 ED63B, 100 70 ED63A, 100 50 ED63A, 50 50 RK5 100 80<br />

HEG3G<br />

HEM3M<br />

HEM3M<br />

3RW44 26 29 ED63B, 100 100 ED63A, 100 100 ED63A, 50 100 RK5 100 125 J 100 250<br />

HEG3G<br />

HEM3M<br />

HEM3M<br />

3RW44 27 34 FD63B 100 150 ED63A, 100 100 ED63A, 50 125 RK5 100 150 J 100 300<br />

HEM3M<br />

HEM3M<br />

3RW44 34 42 FD63B 100 150 FD63B 50 150 ED63A, 100 125 FXD63A 50 150 RK5 100 200 J 100 400<br />

HEM3M<br />

3RW44 35 58 FD63B 100 150 FD63B 50 150 FXD63A 100 150 FXD63A 50 150 RK5 100 200 J 100 400<br />

3RW44 36 62 JD63B 100 200 JD63B 50 250 FXD63A 100 250 FXD63A 50 250 RK5 100 250 J 100 500<br />

3RW44 43 73 JD63B 100 300 JD63B 50 250 FXD63A 100 250 JXD63A 50 300 RK5 100 300 J 100 600<br />

3RW44 44 98 JD63B 100 300 JD63B 50 300 JXD63A 100 300 JXD63A 50 300 RK5 100 350<br />

3RW44 45 98 JD63B 100 400 JD63B 50 400 JXD63A 100 400 JXD63A 50 400 RK5 100 450<br />

3RW44 46 98 LD63B 100 500 LD63B 50 450 LXD63H 100 400 JXD63A 50 400 RK5 100 600<br />

3RW44 47 98 LD63B 100 600 LD63B 50 600 LXD63H 100 600 LXD63H 50 600 L 100 700<br />

3RW44 53 117 HMD6 65 800/ HMD6 50 800/<br />

L 100 1000<br />

800<br />

800<br />

3RW44 54 145 HND6 100 1200/ HND6 50 1200/<br />

L 100 1000<br />

900<br />

900<br />

3RW44 55 145 HND6 100 1200/ HND6 50 1200/<br />

L 100 1000<br />

900<br />

900<br />

3RW44 56 145 HND6 100 1200/ HND6 50 1200/<br />

L 100 1000<br />

1000<br />

1000<br />

3RW44 57 145 HND6 100 1200/ HND6 50 1200/<br />

L 100 1000<br />

1000<br />

1000<br />

3RW44 58 145 CND6 65 1200 CND6 65 1200<br />

3RW44 65 205 CND6 42 1600 CND6 42 1600<br />

3RW44 66 248 CND6 42 1600 CND6 42 1600<br />

Max.<br />

size<br />

A<br />

600 V<br />

Type<br />

SCCR<br />

kA<br />

Max.<br />

size<br />

A<br />

600 V<br />

Type<br />

SCCR<br />

kA<br />

Max.<br />

size<br />

A<br />

600 V<br />

Type<br />

SCCR<br />

kA<br />

Max.<br />

size<br />

A<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Specified Type<br />

ED63A<br />

FXD63A<br />

JXD63A<br />

ED63B<br />

FD63B<br />

JD63B<br />

HND6<br />

Others permitted<br />

HED63A, HHED63A or CED63A<br />

HFXD63A or CFD63A<br />

HJXD63A or CJD63A<br />

HED63B, HHED63B or CED63B<br />

HFD63B, HHFD63B or CFD63B<br />

HJ63B, HHJD63B or CJD63B<br />

HNXD6 or CND6<br />

17-274<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

Inline circuit fused version with 3NE1 SITOR all-range fuse (semiconductor and line protection)<br />

For matching fuse bases see Catalog LV 1 under "SENTRON Switching and Protection Devices for Power<br />

Distribution" ––> "Switch Disconnectors", and Catalog ET B1 under "BETA Protecting" ––> "SITOR<br />

Semiconductor Fuses" or go to www.siemens.com/sitor ––>"Products" ––>"BETA Protecting"––>"SITOR"<br />

Soft starters All-range fuses Line contactors<br />

up to 400 V<br />

2 x 3NE1 435-2 560<br />

690 +10 %<br />

2 x 3NE1 435-2 560<br />

690 +10 %<br />

3 x 3NE1 334-2 500<br />

690 +10 %<br />

3 x 3NE1 435-2 560<br />

690 +10 %<br />

1) If the ramp-down function "Combined braking" is selected, no braking contactor<br />

is required.<br />

If the ramp-down function "DC braking" is selected, a braking contactor<br />

must be used in addition (see table for type).<br />

For applications with large centrifugal masses (J Load > J Motor ) we recommend<br />

the function "DC braking".<br />

Braking contactors 1)2)<br />

(for example circuit see page 17-261)<br />

ToC<br />

2 Rated<br />

Rated current Voltage Size (optional)<br />

current<br />

Q11 F'1 Q21 Q91 Q92<br />

Type A Type A V Type Type Type<br />

Type of coordination "2" 3) : I q = 65 kA<br />

3RW44 22 29 3NE1 020-2 80 690 +5 % 00 3RT10 34 3RT15 26 --<br />

3RW44 23 36 3NE1 020-2 80 690 +5 % 00 3RT10 35 3RT15 26 --<br />

3RW44 24 47 3NE1 021-2 100 690 +5 % 00 3RT10 36 3RT15 35 --<br />

3RW44 25 57 3NE1 022-2 125 690 +5 % 00 3RT10 44 3RT15 35 --<br />

3RW44 26 77 3NE1 022-2 125 690 +5 % 00 3RT10 45 3RT10 24 3RT10 35<br />

3RW44 27 93 3NE1 024-2 160 690 +5 % 1 3RT10 46 3RT10 25 3RT10 36<br />

3RW44 34 113 3NE1 225-2 200 690 +5 % 1 3RT10 54 3RT10 34 3RT10 44<br />

3RW44 35 134 3NE1 227-2 250 690 +5 % 1 3RT10 55 3RT10 36 3RT10 45<br />

3RW44 36 162 3NE1 227-2 250 690 +5 % 1 3RT10 56 3RT10 44 3RT10 45<br />

3RW44 43 203 3NE1 230-2 315 600 +10 % 1 3RT10 64 3RT10 44 3RT10 54<br />

3RW44 44 250 3NE1 331-2 350 460 +10 % 2 3RT10 65 3RT10 44 3RT10 55<br />

3RW44 45 313 3NE1 333-2 450 690 +5 % 2 3RT10 75 3RT10 54 3RT10 56<br />

3RW44 46 356 3NE1 334-2 500 690 +5 % 2 3RT10 75 3RT10 54 3RT10 56<br />

3RW44 47 432 3NE1 435-2 560 690 +5 % 3 3RT10 76 3RT10 55 3RT10 64<br />

3RW44 53 551 2 x 3NE1 334-2 500 690 +10 % 2 3TF68 3RT10 64 3RT10 66<br />

3RW44 54 615 2 x 3NE1 334-2 500 690 +10 % 2 3TF68 3RT10 64 3RT10 75<br />

3RW44 55 693 2 x 3NE1 334-2 500 690 +10 % 2 3TF69 3RT10 65 3RT10 75<br />

3RW44 56 780 2 x 3NE1 435-2 560 690 +10 % 3 3TF69 3RT10 65 3RT10 75<br />

3RW44 57 880 6<br />

3RW44 58 970 6<br />

3RW44 65 1076 8<br />

3RW44 66 1214 8<br />

3<br />

3RT10 75<br />

3RT10 7<br />

3<br />

3RT10 75<br />

3RT10 7<br />

2<br />

3RT10 75<br />

3TF6<br />

3<br />

3RT10 76<br />

3TF6<br />

2) Additional auxiliary relay K4:<br />

LZX:RT4A4T30<br />

(3RW44 soft starter with rated control supply voltage 230 V AC),<br />

LZX:RT4A4S15<br />

(3RW44 soft starter with rated control supply voltage 115 V AC).<br />

3) The type of coordination "2" refers only to soft starters in combination with<br />

the stipulated protective device (motor starter protector/circuit<br />

breaker/fuse), not to any additional components in the feeder.<br />

The types of coordination are explained under "3RA1 Fuseless Load<br />

Feeders".<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-275


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

Inline circuit fused version with 3NE or 3NC SITOR semiconductor fuse<br />

(semiconductor protection by fuse, line and overload protection by motor starter protector/circuit breaker)<br />

For matching fuse bases see Catalog LV 1 under "SENTRON<br />

Switching and Protection Devices for Power Distribution" ––><br />

"Switch Disconnectors", and Catalog ET B1 under "BETA<br />

Protecting" ––> "SITOR Semiconductor Fuses" or go to<br />

rwww.siemens.com/sitor ––>"Products" ––>"BETA Protecting"<br />

––>"SITOR"<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Soft starters Semiconductor fuses, minimum Semiconductor fuses, maximum Semiconductor fuses (cylinder)<br />

Rated current 690 V +10 % Rated current Size 690 V +10 % Rated current Size Rated current Size<br />

ToC<br />

2<br />

Q11 F3 F3 F3<br />

Type A Type A Type A Type A<br />

Type of coordination "2" 3) : I q = 65 kA<br />

3RW44 22 29 3NE4 120 80 0 3NE4 121 100 0 3NC2 280 80 22 x 58<br />

3RW44 23 36 3NE4 121 100 0 3NE4 121 100 0 3NC2 200 100 22 x 58<br />

3RW44 24 47 3NE4 121 100 0 3NE4 122 125 0 3NC2 200 100 22 x 58<br />

3RW44 25 57 3NE4 122 125 0 3NE4 124 160 0<br />

3RW44 26 77 3NE4 124 160 0 3NE4 124 160 0<br />

3RW44 27 93 3NE3 224 160 1 3NE3 332-0B 400 2<br />

3RW44 34 113 3NE3 225 200 1 3NE3 335 560 2<br />

3RW44 35 134 3NE3 225 200 1 3NE3 335 560 2<br />

3RW44 36 162 3NE3 227 250 1 3NE3 333 450 2<br />

3RW44 43 203 3NE3 230-0B 315 1 3NE3 333 450 2<br />

3RW44 44 250 3NE3 230-0B 315 1 3NE3 333 450 2<br />

3RW44 45 313 3NE3 233 450 1 3NE3 336 630 2<br />

3RW44 46 356 3NE3 333 450 2 3NE3 336 630 2<br />

3RW44 47 432 3NE3 335 560 2 3NE3 338-8 800 2<br />

3RW44 53 551 2 x 3NE3 335 560 2 3 x 3NE3 334-0B 500 2<br />

3RW44 54 615 2 x 3NE3 335 560 2 3 x 3NE3 334-0B 500 2<br />

3RW44 55 693 2 x 3NE3 335 560 2 3 x 3NE3 334-0B 500 2<br />

3RW44 56 780 2 x 3NE3 336 630 2 2 x 3NE3 340-8 900 2<br />

3RW44 57 880 2 x 3NE3 336 630 2 2 x 3NE3 340-8 900 2<br />

3RW44 58 970 2 x 3NE3 336 630 2 2 x 3NE3 340-8 900 2<br />

3RW44 65 1076 2 x 3NE3 340-8 900 2 3 x 3NE3 338-8 800 2<br />

3RW44 66 1214 2 x 3NE3 340-8 900 2 3 x 3NE3 338-8 800 2<br />

Soft starters<br />

Line contactors Braking contactors 1)2)<br />

up to 400 V<br />

ToC<br />

(for example circuit see page 17-255)<br />

1076<br />

3RT10 75 3TF68<br />

1214<br />

3RT10 76 3TF68<br />

1) If the ramp-down function "Combined braking" is selected, no braking contactor<br />

is required. If the ramp-down function "DC braking" is selected, a<br />

braking contactor must be used in addition (see table for type).<br />

For applications with large centrifugal masses (J Load > J Motor ) we recommend<br />

the function "DC braking".<br />

Motor starter protectors/<br />

circuit breakers<br />

Line protection, maximum<br />

Rated current (optional) 440 V +10 % Rated current 690 V +5 % Rated current Size<br />

2<br />

Q11 Q21 Q91 Q92 Q1 F1<br />

Type A Type Type Type Type A Type A<br />

Type of coordination "2" 3) : I q = 65 kA<br />

3RW44 22 29 3RT10 34 3RT15 26 -- 3RV10 41-4HA10 50 3NA3 820-6 50 00<br />

3RW44 23 36 3RT10 35 3RT15 26 -- 3RV10 41-4JA10 63 3NA3 822-6 63 00<br />

3RW44 24 47 3RT10 36 3RT15 35 -- 3RV10 41-4KA10 75 3NA3 824-6 80 00<br />

3RW44 25 57 3RT10 44 3RT15 35 -- 3RV10 41-4LA10 90 3NA3 830-6 100 00<br />

3RW44 26 77 3RT10 45 3RT10 24 3RT10 35 3RV10 41-4MA10 100 3NA3 132-6 125 1<br />

3RW44 27 93 3RT10 46 3RT10 25 3RT10 36 3RV10 41-4MA10 100 3NA3 136-6 160 1<br />

3RW44 34 113 3RT10 54 3RT10 34 3RT10 44 3VL17 16 160 3NA3 244-6 250 2<br />

3RW44 35 134 3RT10 55 3RT10 36 3RT10 45 3VL17 16 160 3NA3 244-6 250 2<br />

3RW44 36 162 3RT10 56 3RT10 44 3RT10 45 3VL37 25 250 3NA3 365-6 500 3<br />

3RW44 43 203 3RT10 64 3RT10 44 3RT10 54 3VL47 31 315 2 x 3NA3 354-6 2 x 355 3<br />

3RW44 44 250 3RT10 65 3RT10 44 3RT10 55 3VL47 31 315 2 x 3NA3 354-6 2 x 355 3<br />

3RW44 45 313 3RT10 75 3RT10 54 3RT10 56 3VL47 40 400 2 x 3NA3 365-6 2 x 500 3<br />

3RW44 46 356 3RT10 75 3RT10 54 3RT10 56 3VL47 40 400 2 x 3NA3 365-6 2 x 500 3<br />

3RW44 47 432 3RT10 76 3RT10 55 3RT10 64 3VL57 50 500 2 x 3NA3 365-6 2 x 500 3<br />

3RW44 53 551 3TF68 3RT10 64 3RT10 66 3VL67 80 800 2 x 3NA3 365-6 2 x 500 3<br />

3RW44 54 615 3TF68 3RT10 64 3RT10 75 3VL67 80 800 2 x 3NA3 365-6 2 x 500 3<br />

3RW44 55 693 3TF69 3RT10 65 3RT10 75 3VL67 80 800 2 x 3NA3 365-6 2 x 500 3<br />

3RW44 56 780 3TF69 3RT10 65 3RT10 75 3VL77 10 1000 2 x 3NA3 365-6 2 x 500 3<br />

3RW44 57 880<br />

3RT10 75 3RT10 76<br />

3<br />

3RW44 58 970<br />

3RT10 75 3RT10 76<br />

3<br />

3RW44 65 3<br />

3RW44 66 3<br />

3VL77 10 1000 2 x 3NA3 365-6 2 x 500<br />

3VL77 12 1250 3 x 3NA3 365-6 3 x 500<br />

3VL77 12 1250 3 x 3NA3 365-6 3 x 500<br />

3VL77 12 1250 3 x 3NA3 365-6 3 x 500<br />

2) Additional auxiliary relay K4:<br />

LZX:RT4A4T30<br />

(3RW44 soft starter with rated control supply voltage 230 V AC),<br />

LZX:RT4A4S15<br />

(3RW44 soft starter with rated control supply voltage 115 V AC).<br />

3) The type of coordination "2" refers only to soft starters in combination with<br />

the stipulated protective device (motor starter protector/circuit<br />

breaker/fuse), not to any additional components in the feeder. The types of<br />

coordination are explained under "3RA1 Fuseless Load Feeders".<br />

17-276<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

Inside-delta circuit fused version with 3NE or 3NC SITOR fuses<br />

(semiconductor protection by fuse, lead and overload protection by motor starter protector/circuit breaker)<br />

For matching fuse bases see Catalog LV 1 under "SENTRON<br />

Switching and Protection Devices for Power Distribution" ––><br />

"Switch Disconnectors", and Catalog ET B1 under "BETA Protecting"<br />

––> "SITOR Semiconductor Fuses" or go to<br />

www.siemens.com/sitor ––>"Products" ––>"BETA Protecting"<br />

––>"SITOR"<br />

Soft<br />

Semiconductor fuses, minimum Semiconductor fuses, maximum Semiconductor fuses (cylinder)<br />

starters<br />

ToC<br />

2 Rated 690 V +10 % Rated current Size 690 V +10 % Rated current Size Rated current Size<br />

current<br />

Q11 F3 F3 F3<br />

Type A Type A Type A Type A<br />

Type of coordination "2" 1)<br />

3RW44 22 50 3NE4 120 80 0 3NE4 121 100 0 3NC2 280 80 22 x 58<br />

3RW44 23 62 3NE4 121 100 0 3NE4 121 100 0 3NC2 200 100 22 x 58<br />

3RW44 24 81 3NE4 121 100 0 3NE4 122 125 0 3NC2 200 100 22 x 58<br />

3RW44 25 99 3NE4 122 125 0 3NE4 124 160 0<br />

3RW44 26 133 3NE4 124 160 0 3NE4 124 160 0<br />

3RW44 27 161 3NE3 224 160 1 3NE3 332-0B 400 2<br />

3RW44 34 196 3NE3 225 200 1 3NE3 335 560 2<br />

3RW44 35 232 3NE3 225 200 1 3NE3 335 560 2<br />

3RW44 36 281 3NE3 227 250 1 3NE3 333 450 2<br />

3RW44 43 352 3NE3 230-0B 315 1 3NE3 333 450 2<br />

3RW44 44 433 3NE3 230-0B 315 1 3NE3 333 450 2<br />

3RW44 45 542 3NE3 233 450 1 3NE3 336 630 2<br />

3RW44 46 617 3NE3 333 450 2 3NE3 336 630 2<br />

3RW44 47 748 3NE3 335 560 2 3NE3 338-8 800 2<br />

3RW44 53 954 2 x 3NE3 335 560 2 3 x 3NE3 334-0B 500 2<br />

3RW44 54 1065 2 x 3NE3 335 560 2 3 x 3NE3 334-0B 500 2<br />

3RW44 55 1200 2 x 3NE3 335 560 2 3 x 3NE3 334-0B 500 2<br />

3RW44 56 1351 2 x 3NE3 336 630 2 2 x 3NE3 340-8 900 2<br />

3RW44 57 1524 2 x 3NE3 336 630 2 3 x 3NE3 340-8 900 2<br />

3RW44 58 1680 2 x 3NE3 336 630 2 3 x 3NE3 340-8 900 2<br />

3RW44 65 1864 2 x 3NE3 340-8 900 2 3 x 3NE3 338-8 800 2<br />

3RW44 66 2103 2 x 3NE3 340-8 900 2 3 x 3NE3 338-8 800 2<br />

Soft<br />

starters<br />

Line contactors<br />

up to 400 V<br />

Motor starter protectors/<br />

circuit breakers<br />

954<br />

3VL77 10<br />

1000<br />

1065<br />

3VL77 12<br />

1250<br />

1200<br />

3VL87 16<br />

1600<br />

1351<br />

3VL87 16<br />

1600<br />

1524<br />

3VL87 16<br />

1600<br />

1680<br />

3WL12 20<br />

2000<br />

1864<br />

3WL12 25<br />

2500<br />

2103<br />

3WL12 25<br />

2500<br />

1) The type of coordination "2" refers only to soft starters in combination with<br />

the stipulated protective device (motor starter protector/circuit<br />

breaker/fuse), not to any additional components in the feeder.<br />

Line protection, maximum<br />

ToC<br />

2 Rated (optional) 440 V +10 % Rated current 690 V +5 % Rated current Size<br />

current<br />

Q11 Q21 Q1 F1<br />

Type A Type Type A Type A<br />

Type of coordination "2" 1)<br />

3RW44 22 50 3RT10 36-1AP04 3RV10 42-4KA10 75 3NA3 824-6 80 00<br />

3RW44 23 62 3RT10 44-1AP04 3RV10 42-4LA10 90 3NA3 830-6 100 00<br />

3RW44 24 81 3RT10 46-1AP04 3RV10 42-4MA10 100 3NA3 132-6 125 1<br />

3RW44 25 99 3RT10 54-1AP36 3VL27 16 160 3NA3 136-6 160 1<br />

3RW44 26 133 3RT10 55-6AP36 3VL27 16 160 3NA3 240-6 200 2<br />

3RW44 27 161 3RT10 56-6AP36 3VL37 20 200 3NA3 244-6 250 2<br />

3RW44 34 196 3RT10 64-6AP36 3VL37 25 250 3NA3 360-6 400 3<br />

3RW44 35 232 3RT10 65-6AP36 3VL47 31 315 3NA3 360-6 400 3<br />

3RW44 36 281 3RT10 66-6AP36 3VL47 40 400 2 x 3NA3 360-6 2 x 400 3<br />

3RW44 43 352 3RT10 75-6AP36 3VL47 40 400 2 x 3NA3 365-6 2 x 500 3<br />

3RW44 44 433 3RT10 76-6AP36 3VL57 50 500 2 x 3NA3 365-6 2 x 500 3<br />

3RW44 45 542 3TF68 44-0CM7 3VL57 63 800 3 x 3NA3 365-6 3 x 500 3<br />

3RW44 46 617 3TF68 44-0CM7 3VL67 80 800 3 x 3NA3 365-6 3 x 500 3<br />

3RW44 47 748 3TF69 3VL67 80 800 3 x 3NA3 365-6 3 x 500 3<br />

3RW44 53 3 x 3NA3 365-6 3 x 500<br />

3<br />

3RW44 54 3 x 3NA3 365-6 3 x 500<br />

3<br />

3RW44 55 3 x 3NA3 365-6 3 x 500<br />

3<br />

3RW44 56 3 x 3NA3 372 3 x 630<br />

3<br />

3RW44 57 3 x 3NA3 372 3 x 630<br />

3<br />

3RW44 58 2 x 3NA3 480 2 x 1000<br />

4<br />

3RW44 65 2 x 3NA3 482 2 x 1250<br />

4<br />

3RW44 66 2 x 3NA3 482 2 x 1250<br />

4<br />

The types of coordination are explained under "3RA1 Fuseless Load<br />

Feeders".<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-277


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

Characteristic curves<br />

Motor protection tripping characteristics<br />

for 3RW44 (with symmetry)<br />

10 3<br />

Tripping time [s]<br />

6<br />

4<br />

2<br />

NSB0_01500a<br />

Motor protection tripping characteristics<br />

for 3RW44 (with asymmetry)<br />

[s]<br />

Tripping time<br />

10 3<br />

6<br />

4<br />

2<br />

NSB0_01706<br />

10 2<br />

10 2<br />

6<br />

6<br />

4<br />

4<br />

Soft Starter<br />

Control<br />

2<br />

10 1<br />

6<br />

4<br />

2<br />

10 1<br />

6<br />

4<br />

2<br />

2<br />

10 0<br />

1<br />

2 4 6 10<br />

x e<br />

Class 5 Class 10 Class 15 Class 20 Class 30<br />

10 0<br />

0,1<br />

1,0<br />

10<br />

x e<br />

Class 5 Class 10 Class 15 Class 20 Class 30<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Permissible installation height<br />

Operational rated current I in %<br />

e<br />

105<br />

100<br />

95<br />

90<br />

85<br />

80<br />

75<br />

70<br />

0 1000 2000 3000 4000 5000<br />

Mounting height in m<br />

At an installation height above 2000 m, the max. permissible operational<br />

voltage is reduced to 460 V.<br />

NSB0_01704<br />

17-278<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW44 for high-feature applications<br />

More information<br />

Application examples for normal starting (Class 10)<br />

Normal starting Class 10 (up to 20 s with 350 % I n motor ),<br />

The soft starter rating can be selected to be as high as the rating of the motor used<br />

Application Conveyor belt Roller conveyor Compressor Small fan Pump Hydraulic pump<br />

Starting parameters<br />

• Voltage ramp and current<br />

limiting<br />

- Starting voltage % 70 60 50 30 30 30<br />

- Starting time s 10 10 10 10 10 10<br />

- Current limit value Deactivated Deactivated 4 x I M 4 x I M Deactivated Deactivated<br />

• Torque ramp<br />

- Starting torque 60 50 40 20 10 10<br />

- End torque 150 150 150 150 150 150<br />

- Starting time 10 10 10 10 10 10<br />

• Breakaway pulse<br />

Deactivated (0 ms) Deactivated (0 ms) Deactivated (0 ms) Deactivated (0 ms) Deactivated (0 ms) Deactivated (0 ms)<br />

Ramp-down mode<br />

Smooth<br />

ramp-down<br />

Smooth<br />

ramp-down<br />

Free ramp-down Free ramp-down Pump ramp-down Free ramp-down<br />

Application examples for heavy starting (Class 20)<br />

Heavy starting Class 20 (up to 40 s with 350 % I n motor ),<br />

The soft starter has to be selected one performance class higher than the motor used<br />

Application Stirrer Centrifuge Milling machine<br />

Starting parameters<br />

• Voltage ramp and current<br />

limiting<br />

- Starting voltage % 30 30 30<br />

- Starting time s 30 30 30<br />

- Current limit value 4 x I M 4 x I M 4 x I M<br />

• Torque ramp<br />

- Starting torque 30 30 30<br />

- End torque 150 150 150<br />

- Starting time 30 30 30<br />

• Breakaway pulse Deactivated (0 ms) Deactivated (0 ms) Deactivated (0 ms)<br />

Ramp-down mode Free ramp-down Free ramp-down Free ramp-down or DC braking<br />

Soft Starter<br />

Control<br />

Application examples for very heavy starting (Class 30)<br />

Very heavy starting Class 30 (up to 60 s with 350 % I n motor ),<br />

The soft starter has to be selected two performance classes higher than the motor used<br />

Application Large fan Mill Crusher Circular saw/bandsaw<br />

Starting parameters<br />

• Voltage ramp and current<br />

limiting<br />

- Starting voltage % 30 50 50 30<br />

- Starting time s 60 60 60 60<br />

- Current limit value 4 x I M 4 x I M 4 x I M 4 x I M<br />

• Torque ramp<br />

- Starting torque 20 50 50 20<br />

- End torque 150 150 150 150<br />

- Starting time 60 60 60 60<br />

• Breakaway pulse Deactivated (0 ms) 80 %, 300 ms 80 %, 300 ms Deactivated (0 ms)<br />

Ramp-down mode Free ramp-down Free ramp-down Free ramp-down Free ramp-down<br />

Note:<br />

These tables present sample set values and device sizes. They<br />

are intended only for the purposes of information and are not<br />

binding. The set values depend on the application in question<br />

and must be optimized during commissioning.<br />

The soft starter dimensions should be checked where necessary<br />

with the Win-Soft Starter software or with the help of Technical<br />

Assistance.<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-279


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

Soft Starter<br />

Control<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Circuit concept<br />

The SIRIUS 3RW44 soft starters can be operated in two different<br />

types of circuit.<br />

• Inline circuit<br />

The controls for isolating and protecting the motor are simply<br />

connected in series with the soft starter. The motor is connected<br />

to the soft starter with three cables.<br />

• Inside-delta circuit<br />

The wiring is similar to that of wye-delta starters. The phases of<br />

the soft starter are connected in series with the individual motor<br />

windings. The soft starter then only has to carry the phase current,<br />

amounting to about 58 % of the rated motor current (conductor<br />

current).<br />

Comparison of the types of circuit<br />

Inline circuit:<br />

Rated current I e corresponds to the rated motor current I n ,<br />

3 cables to the motor<br />

Inside-delta circuit:<br />

Rated current I e corresponds to approx. 58 % of the rated motor<br />

current I n , 6 cables to the motor (as with wye-delta starters)<br />

Which circuit?<br />

Using the inline circuit involves the lowest wiring outlay. If the<br />

soft starter to motor connections are long, this circuit is preferable.<br />

With the inside-delta circuit there is double the wiring complexity<br />

but a smaller size of device can be used at the same rating.<br />

Thanks to the choice of operating mode between the inline circuit<br />

and inside-delta circuit, it is always possible to select the<br />

most favorable solution.<br />

The braking function is possible only in the inline circuit.<br />

Configuration<br />

The 3RW44 solid-state soft starters are designed for normal<br />

starting. In case of heavy starting or increased starting frequency,<br />

a larger device must be selected.<br />

For long starting times it is recommended to have a PTC sensor<br />

in the motor. This also applies for the ramp-down modes smooth<br />

ramp-down, pump ramp-down and DC braking, because during<br />

the ramp-down time in these modes, an additional current loading<br />

applies in contrast to free ramp-down.<br />

In the motor feeder between the SIRIUS 3RW soft starter and the<br />

motor, no capacitive elements are permitted (e. g. no reactivepower<br />

compensation equipment). In addition, neither static systems<br />

for reactive-power compensation nor dynamic PFC (Power<br />

Factor Correction) must be operated in parallel during starting<br />

and ramp-down of the soft starter. This is important to prevent<br />

faults arising on the compensation equipment and/or the soft<br />

starter.<br />

All elements of the main circuit (such as fuses and controls)<br />

should be dimensioned for direct starting, following the local<br />

short-circuit conditions. Fuses, controls and overload relays<br />

must be ordered separately.<br />

A bypass contact system and solid-state overload relay are already<br />

integrated in the 3RW44 soft starter and therefore do not<br />

have to be ordered separately.<br />

The harmonic component load for starting currents must be<br />

taken into consideration for the selection of motor starter protectors<br />

(selection of release).<br />

Note:<br />

When induction motors are switched on, voltage drops occur as<br />

a rule on starters of all types (direct starters, wye-delta starters,<br />

soft starters). The infeed transformer must always be dimensioned<br />

such that the voltage dip when starting the motor remains<br />

within the permissible tolerance. If the infeed transformer is dimensioned<br />

with only a small margin, it is best for the control voltage<br />

to be supplied from a separate circuit (independently of the<br />

main voltage) in order to avoid the potential switching off of the<br />

soft starter.<br />

Device interface, PROFIBUS DP communication module,<br />

Soft Starter ES parameterizing and operating software<br />

The 3RW44 electronic soft starters have a PC interface for communicating<br />

with the Soft Starter ES software or for connecting<br />

the external display and operator module. If the optional<br />

PROFIBUS communication module is used, the 3RW44 soft<br />

starter can be integrated in the PROFIBUS network and communicate<br />

using the GSD file or Soft Starter ES Premium software.<br />

The Soft Starter ES parameterizing and operating software can<br />

be downloaded from<br />

www.usa.siemens.com > Software with a 14-day trial license.<br />

More information about Soft Starter ES can be found in<br />

Chapter 12 of Catalog LV 1.<br />

17-280<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

Manual for SIRIUS 3RW44<br />

Besides containing all important information on configuring,<br />

commissioning and servicing, the manual also contains example<br />

circuits and the technical specifications for all devices.<br />

Win-Soft Starter selection and simulation program<br />

With this software, you can simulate and select all Siemens<br />

soft starters, taking into account various parameters such as<br />

mains properties, motor and load data, and special application<br />

requirements.<br />

3RW44 for high-feature applications<br />

The software is a valuable tool, which makes complicated,<br />

lengthy manual calculations for determining the required soft<br />

starters superfluous.<br />

The Win-Soft Starter selection and simulation program can be<br />

downloaded from: www.usa.siemens.com > Software<br />

More information can be found on the Internet at:<br />

www.usa.siemens.com<br />

Soft Starter<br />

Control<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-281


l<br />

For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

Project Planning aids<br />

Dimensional drawings<br />

3RW30 for standard applications<br />

3RW30 1. ... 3RW30 4.<br />

b<br />

h<br />

f<br />

g<br />

d<br />

e<br />

c<br />

a<br />

35<br />

m<br />

Soft Starter<br />

Control<br />

i<br />

NSB0_01945<br />

k<br />

Type/Dimension<br />

(mm)<br />

a b c d e f g h i k l m<br />

3RW30 1.-1. 95 45 62 146 126 14.4 63 5 6.5 35 85 95<br />

3RW30 1.-2. 95 45 62 146 126 14.4 63 5 6.5 35 85 117.2<br />

3RW30 2.-1. 125 45 92 146 126 14.4 63 5 6.5 35 115 125<br />

3RW30 2.-2. 125 45 92 146 126 14.4 63 5 6.5 35 115 150<br />

3RW30 3. 160 55 110 163 140 18 63 5 6.5 30 150 144<br />

3RW30 4. 170 70 110 181 158 22.5 85 5 10 60 160 160<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Clearances to grounded parts (mm) Lateral Top Bottom Fixing screws Tightening torques (Nm)<br />

3RW30 1. 5 60 40 M4<br />

1<br />

3RW30 2. 5 60 40 M4<br />

1<br />

3RW30 3. 30 60 40 M4<br />

1<br />

3RW30 4. 30 60 40 M4<br />

2<br />

3RW30 03-1. (screw terminals)<br />

3RW30 03-2. (spring-type terminals)<br />

3,1<br />

NSC00482<br />

ca. 71<br />

ca. 91<br />

1)<br />

81,6<br />

101,6<br />

7,2<br />

22,5<br />

5<br />

120<br />

1) For mounting onto standard mounting rail TH 35 according to EN 60715.<br />

2) Dimension for screw fixing.<br />

Screw fixing with two 3RP1 903 push-in lugs per 3RW30 03 device.<br />

17-282<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


l<br />

For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

Project Planning aids<br />

3RW40 for standard applications<br />

f<br />

b<br />

h<br />

g<br />

d<br />

e<br />

c<br />

a<br />

35<br />

m<br />

i<br />

NSB0_01891a<br />

Type/Dimension (mm) a b c d e f g h i k l m<br />

3RW40 2.-1. 125 45 92 149 126 14.4 63 5 6.5 35 115 125<br />

3RW40 2.-2. 125 45 92 149 126 14.4 63 5 6.5 35 115 150<br />

3RW40 3. 170 55 110 165 140 18 63 5 6.5 30 150 144<br />

3RW40 4. 170 70 110 183 158 22.5 85 5 10 60 160 160<br />

k<br />

Soft Starter<br />

Control<br />

Clearances to grounded parts (mm) Lateral Top Bottom Fixing screws Tightening torques (Nm)<br />

3RW40 2. 5 60 40 M4<br />

1<br />

3RW40 3. 30 60 40 M4<br />

1<br />

3RW40 4. 30 60 40 M4<br />

2<br />

17 CONTROL<br />

PRODUCTS<br />

Type/Dimension (mm) a b c d e f g h i k l m n o p q<br />

3RW40 5. 180 120 37 17 167 100 223 250 180 148 6.5 153 7 198 9 M6, 10 Nm<br />

3RW40 7. 210 160 48 25 190 140 240 278 205 166 10 166 9 230 11 M8, 15 Nm<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-283


CONTROL<br />

PRODUCTS<br />

17<br />

l<br />

3RW44 2., 3RW44 3. and 3RW44 4. for High-Feature applications<br />

f<br />

b<br />

o<br />

a<br />

e<br />

k<br />

i<br />

For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

Project Planning aids<br />

q<br />

r<br />

c<br />

d<br />

n<br />

g<br />

h<br />

Soft Starter<br />

Control<br />

NSB0_01493a<br />

p<br />

m<br />

Type/Dimension<br />

(mm)<br />

a b c d e f g h i k l m n o p q r<br />

3RW44 2. 180 170 37 11 167 100 240 270 174 148 7.5 153 7 184 6.6 M6, 10 Nm 10<br />

3RW44 3. 180 170 37 17 167 100 240 270 174 148 7.5 153 7 198 9 M6, 10 Nm 10<br />

3RW44 4. 210 210 48 25 190 140 269 298 205 166 16 166 9 230 11 M8, 15 Nm 10<br />

17-284<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


3RW44 5. and 3RW44 6. for High-Feature applications<br />

a<br />

u<br />

v<br />

t<br />

r s<br />

Soft Starter<br />

Control<br />

w<br />

q h<br />

o<br />

p<br />

e<br />

d<br />

f<br />

For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

Project Planning aids<br />

c<br />

b<br />

1)<br />

1L1<br />

3L2<br />

5L3<br />

g<br />

i<br />

k<br />

l<br />

1) For M12 screw, tightening torque max. 35 Nm (310 lb.in).<br />

Type/Dimension<br />

(mm)<br />

2T1<br />

4T2<br />

6T3<br />

m<br />

a b c d e f g h i k l m<br />

3RW44 5. 76 40 14 20 15.5 638.5 590 -- 44 470 510 16.5<br />

3RW44 6. 85 50 14 -- -- 667 660 160 37.5 535 576 16.5<br />

n<br />

NSB0_01831<br />

ad<br />

17 CONTROL<br />

PRODUCTS<br />

Type/Dimension<br />

(mm)<br />

n o p q r s t u v W ad<br />

3RW44 5. 105 253 623 -- -- -- 249 162 152 -- 290<br />

3RW44 6. 103 251 693 43.5 40 20 249 162 151.4 123 290<br />

3RW49 00-0AC00 external display and operator module<br />

Installation cutout for 3RW49 00-0AC00 external display and<br />

operator module<br />

DEVICE<br />

SIRIUS 3RW44<br />

SF<br />

55<br />

60<br />

96<br />

28<br />

29,1<br />

35,6<br />

NSB0_01829<br />

92<br />

NSB0_01830<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-285


For Operation in the Control Cabinet<br />

Revised on 10/31/19<br />

Class 73, 74<br />

Soft Starter<br />

Control<br />

Dimensions are in inches and are for reference only (not for construction). Certain styles may deviate from values indicated.<br />

Non-Combination Class 73<br />

Combination Type Class 74<br />

17<br />

CONTROL<br />

PRODUCTS<br />

N1, N3R, N12, N4 Standard Enclosure<br />

3RW40<br />

3RW44<br />

Amps A B C Ref. Drawing<br />

11 - 73 24 20 10<br />

98 36 24 10<br />

117-145 36 24 16<br />

205-315 36 30 16<br />

385 60 36 16<br />

26 - 68 24 20 16<br />

82 - 117 36 24 16<br />

145 - 215 36 30 16<br />

280 - 385 60 36 16<br />

494 - 780 90 40 18<br />

970 - 1076 90 48 20<br />

N4X Stainless Steel Standard Enclosure<br />

Amps A B C Ref. Drawing<br />

11 - 98 48 36 10<br />

3RW40 117-315 36 30 16<br />

385 60 36 16<br />

26 - 68 24 20 16<br />

82-117 36 24 12<br />

3RW44 145 36 30 12<br />

180-215 36 30 16<br />

280-385 60 36 12<br />

N1, N3R, N12, N4 Standard Enclosure<br />

Amps A B C Ref. Drawing<br />

11 - 62 36 26 8<br />

73 42 32 12<br />

3RW40<br />

98 42 32 12<br />

117 42 38 16<br />

145 - 248 60 38 16<br />

315 - 385 90 40 18<br />

26 - 68 36 32 16<br />

82 - 117 42 38 16<br />

145 - 215 60 38 16<br />

3RW44<br />

280 72 40 18<br />

315 - 384 90 40 18<br />

494 90 40 18<br />

551 - 780 90 40 18<br />

970 - 1076 90 40 18<br />

N1, N12 Fusible<br />

Amps A B C Ref. Drawing<br />

3RW44 494-780 90 48 20<br />

N4X Stainless Steel Standard Enclosure<br />

Amps A B C Ref. Drawing<br />

11 - 98 48 38 10<br />

3RW40 117 - 315 36 30 16<br />

385 60 36 16<br />

26 - 100 42 32 12<br />

3RW44 117 - 145 60 38 16<br />

180 - 385 90 40 20<br />

17-286<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

Project Planning aids<br />

Schematics<br />

3RW30 . . connection examples for control circuit<br />

Control using switches<br />

N(L-) L1 (L +)<br />

ON/OFF<br />

1)<br />

Automatic mode<br />

N(L-)<br />

L1(L+)<br />

ON/OFF<br />

1)<br />

A2<br />

A1<br />

Q11<br />

1<br />

NSB0_01914<br />

A2 A1 1<br />

Q11<br />

NSB0_01895<br />

U s<br />

ON<br />

>5 min<br />

NSB0_01916a<br />

Control by pushbutton<br />

N(L-) L(L+)<br />

OFF<br />

Control of a main contactor<br />

t<br />

Soft Starter<br />

Control<br />

OFF<br />

Q21<br />

N(L-) L1(L+)<br />

ON<br />

A2 A1 1<br />

13 NO 14<br />

A2 A1 1<br />

1)<br />

ON/<br />

OFF<br />

13 NO 14<br />

ON<br />

ON<br />

Q11<br />

NSB0_01942<br />

Q11<br />

NSB0_01997<br />

3RW30 connection examples for main circuit 2)<br />

3RW30 – 3-phase motor with<br />

3NA/3NE fuse<br />

3RV motor starter protector<br />

F1<br />

3NA/3NE<br />

17 CONTROL<br />

PRODUCTS<br />

Q21<br />

3RT<br />

3RV<br />

Q11<br />

3RW30<br />

Q11<br />

3RW30<br />

M<br />

3~<br />

NSB0_01943<br />

M<br />

3~<br />

NSB0_01944<br />

1) Caution: Risk of restarting!<br />

When operating with a switch (ON/OFF) a new, automatic restart will take<br />

place automatically if the start command is still active at terminal 1.<br />

2) As an alternative, the motor feeder can also be installed as a fuseless or as<br />

a fused version. For fuse and switching device coordination, see<br />

"Technical specifications".<br />

The wiring diagrams are provided only as examples.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-287


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

Project Planning aids<br />

3RW40 2. ... 3RW40 4. connection examples for control circuit<br />

Control using switches<br />

N(L-) L1 (L +)<br />

ON/OFF<br />

1)<br />

Automatic mode<br />

N(L-)<br />

L1(L+)<br />

ON/OFF<br />

1)<br />

Control with remote reset<br />

N(L-) L1 (L +)<br />

RESET<br />

ON/OFF<br />

1)<br />

A2<br />

A1<br />

Q11<br />

1<br />

NSB0_01914<br />

A2 A1 1<br />

Q11<br />

NSB0_01895<br />

A2<br />

A1<br />

Q11<br />

1<br />

NSB0_01892<br />

U s<br />

U s<br />

ON<br />

>5 min<br />

NSB0_01916a<br />

100 %<br />

>1,5 s<br />

NSB0_01915<br />

OFF<br />

t<br />

t<br />

Soft Starter<br />

Control<br />

Control of 3RW40 2. ... 3RW40 4.<br />

by pushbutton<br />

N(L-) L(L+)<br />

Control of a main contactor<br />

OFF<br />

ON<br />

A2 A1 1<br />

13 NO 14 24 NO 23 95 96 NC NO 98<br />

Q21<br />

N(L-) L1(L+)<br />

1)<br />

ON/<br />

OFF<br />

A2 A1 1 13 NO 14 24 NO 23<br />

95 96 NC NO 98<br />

Q11<br />

ON<br />

OVERLOAD<br />

FAILURE<br />

NSB0 02007<br />

Q11<br />

RUN<br />

OVERLOAD<br />

FAILURE<br />

NSB0_02008<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Connection example of 3RW40 2. ... 3RW40 4.<br />

for PTC sensors (thermistor motor protection)<br />

Thermoclick<br />

PTC type A<br />

T11/T21<br />

Q11<br />

T12<br />

T22<br />

NSB0_01893<br />

T11/T21<br />

Q11<br />

T12 T22<br />

NSB0_01894<br />

ϑ<br />

ϑ<br />

1) Caution: Risk of restarting!<br />

When operating with a switch (ON/OFF) a new, automatic restart will take<br />

place automatically if the start command is still active at terminal 1.<br />

17-288<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

Project Planning aids<br />

3RW40 5. and 3RW40 7. connection examples<br />

for control circuit<br />

Control by switch using<br />

internal 24 V DC supply external power supply<br />

3RW40 connection examples for main circuit 3)<br />

3RW40 – 3-phase motor with<br />

3NA/3NE fuse<br />

3RV motor starter protector/<br />

3VL circuit breaker<br />

F1<br />

3NA/3NE<br />

Q21<br />

3RT<br />

3RV/3VL<br />

Q11<br />

3RW40<br />

Q11<br />

3RW40<br />

M<br />

3~<br />

NSB0_01489b<br />

M<br />

3~<br />

NSB0_01487c<br />

Control by pushbutton<br />

ON<br />

L1 N<br />

OFF<br />

Soft Starter<br />

Control<br />

A1 A2 1<br />

2 3<br />

13 NO 14 24 NO 23 95 96 NC NO 98<br />

ON<br />

Q11<br />

OVERLOAD<br />

FAILURE<br />

NSB0_01483b<br />

2)<br />

Control of a main contactor<br />

L1<br />

N<br />

A1 A2 1<br />

Q21<br />

ON/OFF 1)<br />

2 3<br />

13 NO 14 24 NO 23 95 96 NC NO 98<br />

17 CONTROL<br />

PRODUCTS<br />

RUN<br />

Q11<br />

OVERLOAD<br />

FAILURE<br />

NSB0_01484b<br />

2)<br />

1) Caution: Risk of restarting!<br />

When operating with a switch (ON/OFF) a new, automatic restart will take<br />

place automatically if the start command is still active at terminal 3.<br />

2) Grounding necessary for fan connection to 3RW40 5...<br />

3) As an alternative, the motor feeder can also be installed as a fuseless or as<br />

a fused version. For fuse and switching device coordination, see<br />

"Technical specifications".<br />

The wiring diagrams are provided only as examples.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-289


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

Project Planning aids<br />

3RW44 connection examples for main and control circuits<br />

Main circuit<br />

Control circuit<br />

Possibility 1a:<br />

Possibility 1:<br />

Inline circuit with motor starter protector and SITOR fuse<br />

Control by pushbutton<br />

(semiconductor protection only)<br />

L1<br />

L2<br />

L3<br />

3/N/PE 400 V AC, 50 Hz<br />

L1<br />

1/N/PE 230 V AC 1) , 50 Hz<br />

Q1<br />

F2<br />

F3<br />

Q11<br />

L1 L2 L3<br />

(optional<br />

semiconductor<br />

protection fuse)<br />

Q11<br />

A1<br />

Stop<br />

S1<br />

2)<br />

Start S2<br />

Motor on right<br />

PS 1<br />

No action<br />

PTC type A<br />

or<br />

Thermoclick<br />

CONTROL<br />

PRODUCTS<br />

17<br />

No action<br />

Reset S3<br />

L+ L- IN1 IN2 IN3 IN4<br />

T1<br />

T2<br />

Soft Starter<br />

Control<br />

M1<br />

PE<br />

T1 T2 T3<br />

U1 V1 W1<br />

M<br />

3~<br />

NSB0_01490b<br />

PE<br />

N<br />

PE<br />

96<br />

A2 13 14 23 24 33 34 95 98<br />

On period<br />

No<br />

action<br />

No<br />

action<br />

Group<br />

error<br />

+<br />

NSB0_01494c<br />

Main circuit<br />

Possibility 1b:<br />

Possibility 1c:<br />

Inline circuit with all-range Inline circuit with line and<br />

protection<br />

SITOR fuse<br />

(line and semiconductor protection) (semiconductor protection only)<br />

1) Permissible values for main and control voltage, see "Technical<br />

specifications".<br />

2) Caution: Risk of restarting!<br />

Because the output is parameterized to "Motor ON", the start command is<br />

automatically active after the reset command and a new, automatic restart<br />

will take place. This applies especially in case of motor protection tripping.<br />

For safety reasons we recommend connecting the group error output (terminals<br />

95/96) in series with the output parameterized to "Motor ON".<br />

17-290<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

Project Planning aids<br />

Main circuit<br />

Possibility 2:<br />

Inline circuit with main contactor<br />

Control circuit<br />

Possibility 2:<br />

Control of a main contactor and control by means of PLC<br />

L1<br />

L2<br />

L3<br />

3/N/PE 400 V AC 1) , 50 Hz<br />

L1<br />

1/N/PE 230 V AC 1) , 50 Hz<br />

Q1<br />

F2<br />

+24 V DC<br />

PLC outputs<br />

PLC inputs<br />

F3<br />

Q21<br />

Q11<br />

M1<br />

PE<br />

L1 L2 L3<br />

T1 T2 T3<br />

U1 V1 W1<br />

M<br />

3~<br />

(optional<br />

semiconductor<br />

protection fuse)<br />

(optional line<br />

contactor if floating<br />

switching of the<br />

motor is planned)<br />

NSB0_01495b<br />

PE<br />

N<br />

Q11 A1<br />

PE<br />

Switch-on duration<br />

Motor right<br />

PS 1<br />

No action<br />

Start 2)<br />

No action<br />

No action<br />

No action<br />

(optional line contactor<br />

if floating switching<br />

of the motor is planned)<br />

Reset<br />

Trip Reset<br />

L+ L- IN1 IN2 IN3 IN4<br />

Group error<br />

A2 13 14 23 24 33 34 95 96 98<br />

Q21<br />

M<br />

PTC type A or<br />

Thermoclick<br />

T1<br />

+<br />

T2<br />

NSB0_01496b<br />

Soft Starter<br />

Control<br />

1) Permissible values for main and control voltage, see "Technical<br />

specifications".<br />

2) Caution: Risk of restarting!<br />

The start command (e. g. from the PLC) must be reset prior to a reset command<br />

because a new, automatic restart will take place automatically if a<br />

start command is active after the reset command. This applies especially<br />

in case of motor protection tripping.<br />

For safety reasons we recommend incorporating the group error output<br />

(terminals 95 and 96) in the controller.<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-291


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

Project Planning aids<br />

Main circuit<br />

Possibility 3a:<br />

Inline circuit with ramp-down function DC braking 3)<br />

(for device types 3RW44 22 to 3RW44 25)<br />

Control circuit<br />

Possibility 3a:<br />

Control of the DC braking contactor 3)<br />

L1<br />

L2<br />

L3<br />

3/N/PE 400 V AC 1) , 50 Hz<br />

L1<br />

1/N/PE 230 V AC 1) , 50 Hz<br />

Q1<br />

F2<br />

+24 V DC<br />

PLC output<br />

F3<br />

L1 L2 L3<br />

(optional<br />

semiconductor<br />

protection)<br />

M<br />

Start 2)<br />

Reset<br />

PTC type A or<br />

Thermoclick<br />

Q11<br />

T1 T2 T3<br />

Q91<br />

No action<br />

No action<br />

Reset<br />

Soft Starter<br />

Control<br />

M1<br />

PE<br />

Q91<br />

2<br />

U1 V1 W1<br />

M<br />

3~<br />

Q91<br />

NSB0_01501b<br />

Q91<br />

PE<br />

N<br />

Q11<br />

A1<br />

L+ L- IN1 IN2 IN3 IN4<br />

PE<br />

DC braking contactor 3)<br />

96<br />

A2 13 14 23 24 33 34 95 98<br />

Switch-on duration Q91 No action Group error<br />

T1<br />

+<br />

T2<br />

NSB0_01502a<br />

Main circuit<br />

Possibility 3b:<br />

Inline circuit with ramp-down function DC braking 3)<br />

(for device types 3RW44 26 to 3RW44 47)<br />

Control circuit<br />

Possibility 3b:<br />

Control of the DC braking contactor 3)<br />

L1<br />

L2<br />

L3<br />

Q1<br />

3/N/PE 400 V AC 1) , 50 Hz<br />

L1<br />

1/N/PE 230 V AC 1) , 50 Hz<br />

F2<br />

+24 V DC<br />

PLC output<br />

17<br />

CONTROL<br />

PRODUCTS<br />

F3<br />

Q11<br />

L1 L2 L3<br />

T1 T2 T3<br />

(optional<br />

semiconductor<br />

protection)<br />

M<br />

Motor right<br />

PS 1<br />

Start 2)<br />

No action<br />

No action<br />

Reset<br />

Reset<br />

PTC type A or<br />

Thermoclick<br />

M1<br />

PE<br />

Q91 Q92<br />

3 3<br />

U1 V1 W1<br />

M<br />

3~<br />

NSB0_01503b<br />

K4<br />

Q92<br />

Q91<br />

K4<br />

Q91<br />

Q92<br />

PE<br />

Q11 A1 L+ L- IN1 IN2 IN3 IN4<br />

PE<br />

DC braking contactor 3)<br />

96<br />

A2 13 14 23 24 33 34 95 98<br />

Switch-on duration<br />

4)<br />

K4<br />

N<br />

No action<br />

Group error<br />

T1<br />

+<br />

T2<br />

NSB0_01504a<br />

1) Permissible values for main and control voltage, see<br />

"Technical specifications".<br />

2) Caution: Risk of restarting!<br />

The start command (e. g. from the PLC) must be reset prior to a reset command<br />

because a new, automatic restart will take place automatically if a<br />

start command is active after the reset command. This applies especially<br />

in case of motor protection tripping.<br />

For safety reasons we recommend incorporating the group error output<br />

(terminals 95 and 96) in the controller.<br />

3) If the ramp-down function "Combined braking" is selected, no braking contactor<br />

is required.<br />

If the ramp-down function "DC braking" is selected, a braking contactor<br />

must be used in addition. For type see "Fuse Assignment (Inline Circuit)"<br />

on pages 17-238 to 17-240.<br />

For applications with large centrifugal masses (J Load > J Motor ) we recommend<br />

the function "DC braking".<br />

The output 2 must be switched over to "DC braking contactor".<br />

4) Auxiliary relay K4, e. g.:<br />

LZX:RT4A4T30 (230 V AC rated control supply voltage),<br />

LZX:RT4A4S15 (115 V AC rated control supply voltage).<br />

17-292<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

Project Planning aids<br />

Main circuit<br />

Control circuit<br />

Possibility 4a: Possibility 4b: Possibility 4:<br />

Inside-delta circuit<br />

Change of direction of rotation for Control by means of PLC<br />

inside-delta circuit<br />

L1<br />

1/N/PE 230 V AC 1) , 50 Hz<br />

F2<br />

+24 V DC<br />

PLC outputs<br />

PLC inputs<br />

M<br />

Start 2)<br />

Reset<br />

PTC type A or<br />

Thermoclick<br />

PE<br />

N<br />

Q11<br />

PE<br />

A1<br />

Motor right<br />

L+ L- IN1 IN2 IN3 IN4<br />

Group error<br />

A2 13 14 23 24 33 34 95 96 98<br />

Switch-on duration No action No action<br />

No action<br />

No action<br />

Trip Reset<br />

T1<br />

+<br />

T2<br />

NSB0_01498b<br />

Soft Starter<br />

Control<br />

1) Permissible values for main and control voltage, see<br />

"Technical specifications".<br />

2) Caution: Risk of restarting!<br />

The start command (e. g. from the PLC) must be reset prior to a reset command<br />

because a new, automatic restart will take place automatically if a<br />

start command is active after the reset command. This applies especially<br />

in case of motor protection tripping.<br />

For safety reasons we recommend incorporating the group error output<br />

(terminals 95 and 96) in the controller.<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-293


Control Products<br />

Class 73, 74<br />

CONTROL<br />

PRODUCTS<br />

17<br />

Soft Starter<br />

Control<br />

17-294<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Push SIRIUS Button ACT Pushbuttons Units and Indicator Lights Lights<br />

SIRUS ACT 3SU Series<br />

General data<br />

Overview<br />

Benefits<br />

Design<br />

Communication<br />

plastic<br />

black<br />

Ø 22 mm<br />

plastic<br />

metal ring<br />

matte<br />

Ø 22 mm<br />

Color selection<br />

metal<br />

shiny<br />

Ø 22 mm<br />

metal matte<br />

flat<br />

Ø 30 mm<br />

IC01_00478<br />

Pilot Devices<br />

SIRIUS ACT is available in four design lines.<br />

Ruggedness<br />

• Direct connection of the enclosure to AS-Interface or IO-Link<br />

• Direct connection in the control cabinet to PROFINET, IO-Link<br />

or AS-Interface<br />

• Can be integrated easily via the TIA Portal<br />

Easy handling<br />

• Degree of protection IP66, IP67, IP69 (IP69K)<br />

6 = Protection against the<br />

ingress of dust<br />

6 = Protection against the<br />

ingress of dust<br />

IP66<br />

IP67<br />

6 = Protection against powerful splashwater<br />

7 = Protection against temporary<br />

immersion<br />

• Self-holding function of the actuator when mounting<br />

• Twist prevention integrated into patented holder design<br />

• Stackable contact modules<br />

• Self-explanatory and fast installation using one hand<br />

• Components can be mounted with holder removed<br />

• No special tools required, simple size 2 screwdriver<br />

(cross-tip DIN ISO 87641PZD1, flat-head DIN ISO 2380-1 A/B<br />

1x4.5) is sufficient<br />

17 CONTROL<br />

PRODUCTS<br />

13<br />

IP69 (IP69K)<br />

6 = Protection against the<br />

ingress of dust<br />

• Service life of 100 000 hours thanks to use of LEDs<br />

• Media resistance (chemicals) thanks to solid stainless steel<br />

and high-grade plastics<br />

• Mechanical endurance of 10 x 10 6 switching cycles<br />

• Suitable for use in extreme environments<br />

• Reliable, friction-locked fixing with just one screw<br />

• Design stability according to use<br />

• Simple geometry for mounting holes<br />

13/6 Siemens IC 10 N · 04/2016<br />

9/9K = Protection against water in<br />

high-pressure cleaning (approx. 80 bar)<br />

and high water jet temperatures<br />

(approx. 80 °C)<br />

These two pages are a brief overview of the<br />

SIRIUS ACT 3SU Series. Please consult the<br />

Siemens Industrial Control products catalog for<br />

a complete listing of products or look for<br />

info online at usa.siemens.com/sirius-act<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-295


Push Button Units and Indicator Lights<br />

SIRIUS ACT Pushbuttons and Indicator Lights<br />

SIRUS ACT 3SU Series<br />

General data<br />

Actuating and signaling elements<br />

Revised on 04/30/18<br />

Overview<br />

13<br />

1<br />

14<br />

Pilot Devices<br />

2<br />

3<br />

15<br />

16<br />

4<br />

5<br />

6<br />

7<br />

9<br />

8<br />

17<br />

10<br />

11<br />

17<br />

CONTROL<br />

PRODUCTS<br />

12<br />

18<br />

19<br />

20<br />

21<br />

IC01_00424b<br />

13<br />

Actuating and signaling elements Pages Modules for front plate mounting Pages<br />

$ Pushbuttons, illuminated pushbuttons 10/39 2 Contact modules<br />

10/112<br />

% Mushroom pushbuttons 10/41 3 LED modules<br />

10/116<br />

& Selector switches 10/42 4 AS-Interface modules<br />

10/118<br />

()* Key-operated switches, potentiometers, indicator lights 10/43 Enclosures Pages<br />

+, EMERGENCY STOP mushroom pushbuttons,<br />

10/41 5 Enclosures<br />

10/122<br />

backing plates<br />

-. ID key-operated switches, ID keys, electronic modules 10/59 Modules for base mounting Pages<br />

/ Twin pushbuttons, label holders, labeling plates 10/51 6 Contact modules<br />

10/131<br />

0 Label holders, labeling plates 10/136 7 LED modules<br />

10/131<br />

Holders and labels Pages 8 IO-Link modules<br />

10/134<br />

1 Holders 10/136 9 AS-Interface modules<br />

10/134<br />

System overview of SIRIUS ACT pushbuttons and indicator lights<br />

from the plastic design line.<br />

Pushbuttons and indicator lights available in 4 design lines.<br />

Page links above reference the U.S. Industrial Controls catalog available online<br />

17-296<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

13/8 Siemens IC 10 N · 04/2016


Pushbutton Units and Indicator Lights<br />

30 mm Heavy Duty, Watertight/Oiltight, Class 52 Pushbutton complete units<br />

Features<br />

• Octagonal Mounting Nuts<br />

• Meets Type 1, 3, 3R, 4, 4X, 12, 13 and<br />

Automotive Standards<br />

• Heavy Duty Rated NEMA A600/P600<br />

Contacts<br />

• Positively Driven Contacts<br />

• Positive Indexing Selectors<br />

• Bifurcated Movable Contacts<br />

• Attractive Chrome Plating<br />

• Boots Not Required for Type 4<br />

• UL Listed File # E22655<br />

• CSA Certified File # LR6535<br />

• Touchsafe Terminals<br />

Application<br />

Oil tight pilot controls and accessories are<br />

designed to provide long, trouble free serv ice in<br />

the most demanding industrial appli cations.<br />

These controls are oil and dust tight and meet<br />

Type 3, 4, 4X, 12 and 13 specifica tions.<br />

Rugged<br />

Industrial control operators are durable one<br />

piece castings. Heavy duty plastic buttons<br />

resist oils and corrosion. Silver contacts carry<br />

heavy duty ratings.<br />

Flexible<br />

Accessories modify standard push buttons,<br />

selector switches and pilot lights. Building<br />

block construction of contact blocks makes<br />

possible many circuitry combinations.<br />

Industrial Appearance<br />

Pilot controls add luster to panels. Chrome<br />

plating covers exposed metal parts.<br />

Push Button Operators<br />

The Operator Base consists of a durable, one<br />

piece casting equipped with a heavy duty<br />

actuator with a stainless steel spring, a<br />

neoprene actuator sealing ring to prevent oil<br />

and dust from penetrating to the contact<br />

blocks, a neoprene gasket to seal operator<br />

mounting hole and a chrome plated lock nut.<br />

Mushroom Head Push Button Operators<br />

The Mushroom Head base construction is<br />

identical to the push button base. The actua tor<br />

is molded of high impact material for ei ther a 1<br />

5⁄8 inch or 2 1⁄2 inch diameter molded head.<br />

E-STOP Mushroom Head Operators according<br />

to EN 60947-5-5 Cat. No. 52BP, 52BR, 52PP,<br />

and 52PR, 2 Position, Twist-To-Release & 2<br />

Position, Push Pull Maintained operators<br />

provided with red operating heads and 52BJK<br />

contact blocks meet the requirements of EN<br />

60947-5-5 for Electrical Emergency Stop<br />

Device With Mechanical Latching Function<br />

(e-stop).<br />

Contact Blocks<br />

Contact Blocks have double break bifurcated<br />

silver contacts, with gold flashing as standard,<br />

which improves contact reliability. Contact<br />

blocks are heavy duty rated NEMA A600 and<br />

suitable for applications down to 5V/1MA solid<br />

state outputs. 52BJK offers<br />

Positive Opening Contacts according to IEC<br />

60947-5-1, Appendix K. Molded bodies and<br />

pushers resist arcing and tracking. All units<br />

have stainless steel springs that resist<br />

corrosion and provide strong contact pressure.<br />

Captive mounting screws speed panel<br />

assembly.<br />

Push Pull Operators<br />

Push Pull Operators combine two or three<br />

functions in one unit. The maintained opera tor<br />

has two positions, typically pull to start, push to<br />

stop. The momentary operator with three<br />

positions provides spring return from both pull<br />

and push positions. In addition, a three position<br />

push maintained, pull momen tary operator is<br />

available. The actuator come is 1 3/4 inch or 2<br />

1/2 inch diameter and is available in an<br />

illuminated version.<br />

2 Button Maintained Operator<br />

Maintained Push Buttons consist of two push<br />

buttons and a latching assembly. When<br />

ac tuated the button remains depressed and is<br />

freed only by the release operator to which it is<br />

linked. The button assembly adjusts for<br />

mounting from a 1 13⁄16 inch to a 2 5⁄8 inch<br />

center.<br />

Transformer Type Pilot Lights<br />

Transformer Type Pilot Lights are available with<br />

a 120, 240, 480 or 600 Volt primary (50/60<br />

Hertz) and a separate secondary winding<br />

which supplies reduced voltage to a minia ture<br />

bayonet base 6 Volt lamp. These units are<br />

suitable for applications where vibration is<br />

present and long bulb life is desirable.<br />

Full Voltage Type Pilot Lights<br />

Full Voltage Pilot Lights are available for 6,12,<br />

24 and 120 Volt AC and DC applications.<br />

Electrical Ratings<br />

NEMA AC Ratings 50/60Hz<br />

NEMA A600 10 Continuous Amps<br />

Volts Make Break<br />

120 60 6<br />

240 30 3<br />

480 15 1.5<br />

600 12 1.2<br />

VA 7200 720<br />

Ordering Information<br />

• Accessories: pages 17-321 – 17-324<br />

• Selector Position and Contact Operation:<br />

page 17-319 – 17-320.<br />

• Legend Plates: page 17-333.<br />

• Enclosures: page 17-334.<br />

• Technical Specifications: page 17-335.<br />

Resistor Type Pilot Lights<br />

Resistor Type Pilot Lights are available for 240<br />

Volt AC and DC applications. The 240 Volt<br />

pilot light is supplied with a 120 Volt lamp and<br />

a voltage dropping resistor.<br />

LED Type Pilot Lights<br />

LED’s (light emitting diodes) can be used in<br />

pilot lights instead of incandescent bulbs<br />

because of their long life (up to 10 years),<br />

resistance to vibration and ambient sensitivity.<br />

Clusted LED options are available for standard<br />

pilot lights only. Cluster LED options are not<br />

available on Push to test Pilot Lights,<br />

Illuminated Pushbuttons, Push-pull, or<br />

Twist-to-Release Operators.<br />

Integrated LED Module Type Pilot Lights<br />

The integrated LED module is available for 24,<br />

120, and 240 V. LED modules are vibration<br />

resistant and have a long life (up to 10 years).<br />

The integrated LED module is available for 24,<br />

120, and 240 V. LED modules are vibra tion<br />

resistant and have a long life (up to 10 yrs.).<br />

Selector Operators<br />

Selector Operators have positive action<br />

in dexing. Operators are available with either a<br />

short or long lever. The molded black lever is<br />

designed to accept a color insert. A white in sert is<br />

provided as standard. Each operator is<br />

equipped with a cam to actuate plungers of<br />

contact blocks assembled behind the op erator.<br />

Two, three and four position operators are<br />

available with seven different cams.<br />

Lever color inserts are available in 8 colors.<br />

Pilot Devices<br />

17 CONTROL<br />

PRODUCTS<br />

Indicator Light Push Button Selector Switch Selector Push Button<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-297


Push Buttons & Signaling Devices<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Push Button<br />

Selection Guid<br />

Momentary Push Button - Non-Illuminated<br />

Pilot Devices<br />

Part Number<br />

Flush Head Extended Head Large Mushroom Head 2 1/2˝<br />

Small Mushroom Head 1 3/4˝<br />

52 M _______ _______ _______<br />

1<br />

a b c d e<br />

17<br />

CONTROL<br />

PRODUCTS<br />

a<br />

Code Finish<br />

P Chrome - Command 52<br />

B<br />

Epoxy Coated - Black Max<br />

b Code Type<br />

M<br />

Momentary Push Button<br />

c Code Style / Head Type<br />

8A<br />

8B<br />

9A<br />

9W<br />

9V<br />

Flush / Extended Cap 2<br />

Flush<br />

Extended<br />

Mushroom Head Metal<br />

Small Mushroom Head 1 3/4” (44.5mm)<br />

Mushroom Head Plastic<br />

Small Mushroom Head 1 3/4” (44.5mm)<br />

Large Mushroom Head 2 1/2” (63.5mm)<br />

1 For operator without contact blocks leave position e blank.<br />

2 Products available fall 2014. For current product offer please refer to the<br />

2010 Industrial Control Catalog.<br />

d<br />

Code Plastic Metal<br />

1 Black —<br />

e<br />

2 Red Red<br />

3 Green Green<br />

4 Yellow —<br />

5 Blue —<br />

6 Gray —<br />

7 All Color Caps —<br />

8 Orange —<br />

C — Chrome<br />

1 Code Contact Blocks<br />

A<br />

B<br />

C<br />

D<br />

E<br />

F<br />

G<br />

H<br />

J<br />

K<br />

1 NO + 1 NC<br />

2 NO + 2 NC<br />

3 NO + 3 NC<br />

4 NO + 4 NC<br />

1 NC (LB)<br />

2 NO<br />

2 NC<br />

1NO (EM)<br />

1 NC<br />

1 NO<br />

17-298<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: PILO


Push Buttons & Signaling Devices<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Push Buttons<br />

Selection Tables<br />

Momentary Push Button - Non-Illumniated<br />

Finish<br />

Head Style Contacts Color Chrome Black Max<br />

Flush<br />

Extended<br />

Mushroom<br />

Head Plastic<br />

Ø 1 3/4”<br />

Mushroom<br />

Head Plastic<br />

Ø 2 1/2”<br />

Readily available items are in bold.<br />

This is a small representation of stocked items.<br />

Less cap 52PM8 52BM8<br />

Black 52PM8A1 52BM8A1<br />

—<br />

Red 52PM8A2 52BM8A2<br />

Green 52PM8A3 52BM8A3<br />

Yellow 52PM8A4 52BM8A4<br />

Black 52PM8A1A 52BM8A1A<br />

1 NO - 1 NC<br />

Red 52PM8A2A 52BM8A2A<br />

Green 52PM8A3A 52BM8A3A<br />

Black 52PM8A1K 52BM8A1K<br />

1 NO<br />

Red 52PM8A2K 52BM8A2K<br />

Green 52PM8A3K 52BM8A3K<br />

1 NC Red 52PM8A2J 52BM8A2J<br />

Black 52PM8B1 52BM8B1<br />

—<br />

Red 52PM8B2 52BM8B2<br />

Green 52PM8B3 52BM8B3<br />

1 NO<br />

Black 52PM8B1K 52BM8B1K<br />

Red 52PM8B2K 52BM8B2K<br />

1 NC Red 52PM8B2J 52BM8B2J<br />

—<br />

Less cap 52PM9 52BM9<br />

Red 52PM9W2 52BM9W2<br />

1 NO Green 52PM9W3K 52BM9W3K<br />

1 NO - 1 NC<br />

Black 52PM9W1A 52BM9W1A<br />

Red 52PM9W2A 52BM9W2A<br />

1 NO - 1 NC Green 52PM9W3A 52BM9W3A<br />

— Red 52PM9V2 52BM9V2<br />

Black 52PM9V1A 52BM9V1A<br />

1 NO - 1 NC<br />

Red 52PM9V2A 52BM9V2A<br />

Green 52PM9V3A 52BM9V3A<br />

Pilot Devices<br />

17 CONTROL<br />

PRODUCTS<br />

Product Category: PILO<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-299


Push Buttons & Signaling Devices<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Non-Illuminated Push Pull<br />

Selection Guide<br />

2 & 3 Position Push-Pull Mushroom Head Devices - Non-Illuminated<br />

Pilot Devices<br />

Part Number<br />

Mushroom Head Metal Ø 1 3/4˝ Mushroom Head Plastic Ø 2 1/2˝ Mushroom Head Plastic Ø 1 3/4˝<br />

52 _______ P _______ _______ _______ _______<br />

a b c d e f 3<br />

17<br />

CONTROL<br />

PRODUCTS<br />

a<br />

Code Finish<br />

P Chrome-Command 52<br />

B<br />

Epoxy Coated-Black Max<br />

b Code Type<br />

P<br />

Push Pull<br />

c Code Function<br />

2 2 positions - maintained 1<br />

3 3 positions - momentary in - momentary out<br />

7 3 positions - maintained in - momentary out<br />

d<br />

Code Style<br />

A<br />

Small metal 1-3/4” (44.5 mm)<br />

W<br />

V<br />

Small plastic 1-3/4” (44.5 mm)<br />

Large plastic 2-1/2” (63.5 mm)<br />

e Code Color<br />

Plastic<br />

Metal<br />

1 Black —<br />

2 Red 1 Red 1<br />

3 Green Green<br />

4 Yellow —<br />

5 Blue —<br />

6 Gray —<br />

8 Orange —<br />

C — Chrome<br />

f 3 Code Contact Blocks<br />

2 Position<br />

A 1 NO + 1 NC 1<br />

B 2 NO + 2 NC 1<br />

C 3 NO + 3 NC 1<br />

D 4 NO + 4 NC 1<br />

E<br />

1 NC (LB)<br />

F<br />

2 NO<br />

G 2 NC 1<br />

H<br />

1 NO (EM)<br />

J 1 NC 1<br />

K<br />

1 NO<br />

Q<br />

1 NO - 1 NC (ELB)<br />

3 Position<br />

U 1 NO - 1 NC extra late break 2<br />

No Operating Head<br />

Z<br />

No head<br />

1 EMERGENCY-STOP control devices according to IEC 60947-5-5 when provided<br />

with red operating head and positively driven NC contact blocks. Positive<br />

opening contacts according to IEC 60947-5-1, Appendix K.<br />

2 Blocks cannot be interchanged (stop-start circuit - pull to start, push to stop).<br />

3 For operator without contact blocks leave position f blank.<br />

17-300<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: PILO


Push Buttons & Signaling Devices<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Non-Illuminated Push Pull<br />

Selection Tables<br />

2 & 3 Position Push-Pull Mushroom Head Devices - Non-Illuminated<br />

2 pos - maintained<br />

Metal Ø 1 3/4” Plastic Ø 1 3/4” Plastic Ø 2 1/2”<br />

Contacts Color Chrome Black Max Chrome Black Max Chrome Black Max<br />

Black — — 52PP2W1 52BP2W1 52PP2V1 2BP2V1<br />

—<br />

Red 52PP2A2 52BP2A2 52PP2W2 52BP2W2 52PP2V2 52BP2V2<br />

Green 52PP2A3 52BP2A3 52PP2W3 52BP2W3 52PP2V3 52BP2V3<br />

Yellow — — 52PP2W4 52BP2W4 52PP2V4 52BP2V4<br />

Red 52PP2A2A 1 52BP2A2A 1 52PP2W2A 1 52BP2W2A 1 52PP2V2A 1 52BP2V2A 1<br />

1 NO - 1 NC<br />

Green 52PP2A3A 52BP2A3A 52PP2W3A 52BP2W3A 52PP2V3A —<br />

Yellow — — 52PP2W4A 52BP2W4A 52BP2V4A 52BP2V4A<br />

Chrome 52PP2ACA 52BP2ACA — — — —<br />

Pilot Devices<br />

3 pos - momentary in - momentary out<br />

Metal Ø 1 3/4” Plastic Ø 1 3/4” Plastic Ø 2 1/2”<br />

Contacts Color Chrome Black Max Chrome Black Max Chrome Black Max<br />

Black — — 52PP3W1 52BP3W1 52PP3V1 52BP3V1<br />

—<br />

Red 52PP3A2 52BP3A2 52PP3W2 52BP3W2 52PP3V2 52BP3V2<br />

Green 52PP3A3 52BP3A3 52PP3W3 52BP3W3 52PP3V3 2BP3V3<br />

Chrome 52PP3AC 52BP3AC — — — —<br />

1 NO - 1 NCELB<br />

Red 52PP3A2U 52BP3A2U 52PP3W2U 52BP3W2U 52PP3V2U 52BP3V2U<br />

Green 52PP3A3U 52BP3A3U 52PP3W3U 52BP3W3U 52PP3V3U 52BP3V3U<br />

3 pos - maintained in - momentary out<br />

Metal Ø 1 3/4” Plastic Ø 1 3/4” Plastic Ø 2 1/2”<br />

Contacts Color Chrome Black Max Chrome Black Max Chrome Black Max<br />

—<br />

1 NO - 1 NCELB<br />

Black — — 52PP7W1 52BP7W1 52PP7V1 52BP7V1<br />

Red 52PP7A2 52BP7A2 52PP7W2 52BP7W2 52PP7V2 52BP7V2<br />

Green 52PP7A3 52BP7A3 52PP7W3 52BP7W3 52PP7V3 52BP7V3<br />

Chrome 52PP7AC 52BP7AC — — — —<br />

Red 52PP7A2U1 52BP7A2U 52PP7W2U 52BP7W2U 52PP7V2U 52BP7V2U<br />

Green 52PP7A3U 52BP7A3U 52PP7W3U 52BP7W3U 52PP7V3U 52BP7V3U<br />

Readily available items are in bold.<br />

This is a small representation of stocked items.<br />

17 CONTROL<br />

PRODUCTS<br />

1 EMERGENCY-STOP control devices according to IEC 60947-5-5<br />

Product Category: PILO<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-301


Push Buttons & Signaling Devices<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Illuminated Push Pull & Push Button<br />

Selection Guide<br />

2 & 3 Position Push-Pull Mushroom Head Devices - Illuminated<br />

Pilot Devices<br />

Part Number<br />

Mushroom Head Metal Ø 1 3/4” Mushroom Head Plastic Ø 2 1/2” Mushroom Head Plastic Ø 1 3/4”<br />

52 _______ P _______ _______ _______ _______ _______<br />

a b c d e f g<br />

17<br />

CONTROL<br />

PRODUCTS<br />

a<br />

Code Finish<br />

P Chrome-Command 52<br />

B<br />

Epoxy Coated-Black Max<br />

b<br />

Code Type<br />

P<br />

Push Pull Operator<br />

c<br />

Code Function<br />

2 2 positions - maintained 1<br />

3 3 positions - momentary in - momentary out 2<br />

7 3 positions - maintained in - momentary out 2<br />

d Code Operation<br />

Full Voltage 3 (AC/DC )<br />

Incandescent LED 4<br />

B 6-8V 6V<br />

C 12-13V —<br />

D 24-28V 24-28V<br />

E 120V 120V<br />

F — 240V<br />

G<br />

H<br />

J<br />

K<br />

Transformer 3<br />

120V AC<br />

240V AC<br />

480V AC<br />

600V AC<br />

e<br />

Code Style / Color<br />

Mushroom Head Metal Ø 1 3/4” (44.5mm)<br />

2 Red 1<br />

3 Green<br />

5 Blue<br />

9 Amber<br />

A<br />

Clear<br />

B<br />

White<br />

Mushroom Head Plastic Ø 1 3/4” (44.5 mm)<br />

R Red 1<br />

S<br />

Green<br />

T<br />

Amber<br />

Mushroom Head Plastic Ø 2 1/2” (63.5mm)<br />

D Red 1<br />

E<br />

Green<br />

F<br />

Amber<br />

Z<br />

No Head (full voltage & transformer only)<br />

No head<br />

f<br />

Code Contact Blocks<br />

2 Position<br />

A 1 NO + 1 NC 1<br />

B 2 NO - 2 NC 1<br />

F<br />

2 NO<br />

G 2 NC 1<br />

J 1 NC 1<br />

K<br />

1 NO<br />

Q<br />

1 NO - 1 NC (ELB)<br />

1 EMERGENCY-STOP control devices according to IEC 60947-5-5 when provided with<br />

red operating head and positively driven NC contact blocks.<br />

Positive opening contacts according to IEC 60947-5-1, Appendix K,<br />

2 Blocks cannot be interchanged (stop-start circuit - pull to start, push to stop).<br />

3 Default bulb type is incandescent. For LED options, append field g. LED option not<br />

available on units sold “no head”.<br />

4 LED voltages apply to table g option code B and Y.<br />

6V and 120V are currently AC only. Replaced by AC/DC rated versions end of 2014.<br />

5 Not available in 240V.<br />

3 Position<br />

U 1 NO - 1 NC extra late break 2<br />

g Code Bulb Type<br />

Blank<br />

Incandescent<br />

B<br />

LED<br />

Y Super-Bright LED 5<br />

17-302<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: PILO


Push Buttons & Signaling Devices<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Illuminated Push Pull<br />

Selection Tables<br />

Operator Type<br />

2 pos - maintained<br />

Metal Ø 1 3/4” Plastic Ø 1 3/4”<br />

Type Lamp Type Voltage Color Contacts Chrome Black Max Chrome Black Max<br />

Red 1 NO - 1 NC 52PP2D2AB 1 52BP2D2AB 1 52PP2DRAB 1 52BP2DRAB 1<br />

LED<br />

24V<br />

Green 1 NO - 1 NC 52PP2D3AB 52BP2D3AB 52PP2DSAB 52BP2DSAB<br />

Full Voltage<br />

Red 1 NO - 1 NC 52PP2D2A 1 52BP2D2A 1 52PP2DRA 1 52BP2DRA 1<br />

24V<br />

(AC/DC)<br />

Green 1 NO - 1 NC 52PP2D3A 52BP2D3A 52PP2DSA 52BP2DSA<br />

Incandescent<br />

1 NO - 1 NC 52PP2E2A 1 52BP2E2A 1 52PP2ERA 1 52BP2ERA 1<br />

120V Red<br />

— 52PP2E2 52BP2E2 52PP2ER 52BP2ER<br />

Red 1 NO - 1 NC 52PP2G2AB 1 52BP2G2AB 1 52PP2GRAB 1 52BP2GRAB 1<br />

LED<br />

120V<br />

Transformer<br />

Green 1 NO - 1 NC 52PP2G3AB 52BP2G3AB 52PP2GSAB 52BP2GSAB<br />

(AC)<br />

Red 1 NO - 1 NC 52PP2G2A 1 52BP2G2A 1 52PP2GRA 1 52BP2GRA 1<br />

Incandescent 120V<br />

Green 1 NO - 1 NC 52PP2G3A 52BP2G3A 52PP2GSA 52BP2GSA<br />

Pilot Devices<br />

Operator Type<br />

3 pos - momentary in - momentary out<br />

Metal Ø 1 3/4” Plastic Ø 1 3/4”<br />

Type Lamp Type Voltage Color Contacts Chrome Black Max Chrome Black Max<br />

LED 24V Green 1 NO - 1 NCELB 52PP3D3UB 52BP3D3UB 52PP3DRUB 52BP3DRUB<br />

Full Voltage<br />

Green 1 NO - 1 NCELB 52PP3D3U 52BP3D3U 52PP3DSU 52BP3DSU<br />

24V<br />

(AC/DC) Incandescent<br />

Red 1 NO - 1 NCELB 52PP3D2U 52BP3D2U 52PP3DRU 52BP3DRU<br />

120V Red — 52PP3E2 52BP3E2 52PP3ER 52BP3ER<br />

Red 1 NO - 1 NCELB 52PP3G2UB 52BP3G2UB 52PP3GRUB 52BP3GRUB<br />

LED<br />

120V<br />

Transformer<br />

Green 1 NO - 1 NCELB 52PP3G3UB 52BP3G3UB 52PP3GSUB 52BP3GSUB<br />

(AC)<br />

Red 1 NO - 1 NCELB 52PP3G2U 52BP3G2U 52PP3GRU 52BP3GRU<br />

Incandescent 120V<br />

Green 1 NO - 1 NCELB 52PP3G3U 52BP3G3U 52PP3GRU 52BP3GRU<br />

Operator Type<br />

3 pos - maintained in - momentary out<br />

Metal Ø 1 3/4” Plastic Ø 1 3/4”<br />

Type Lamp Type Voltage Color Contacts Chrome Black Max Chrome Black Max<br />

LED 24V Green 1 NO - 1 NCELB 52PP7D3UB 52BP7D3UB 52PP7DSUB 52BP7DSUB<br />

Full Voltage<br />

Green 1 NO - 1 NCELB 52PP7D3U 52BP7D3U 52PP7DSU 52BP7DSU<br />

24V<br />

(AC/DC) Incandescent<br />

Red 1 NO - 1 NCELB 52PP7D2U 52BP7D2U 52PP7DRU 52BP7DRU<br />

120V Red — 52PP7E2 52BP7E2 52PP7ER 52BP7ER<br />

Red 1 NO - 1 NCELB 52PP7G2UB 52BP7G2UB 52PP7GRUB 52BP7GRUB<br />

LED<br />

120V<br />

Transformer<br />

Green 1 NO - 1 NCELB 52PP7G3UB 52BP7G3UB 52PP7GSUB 52BP7GSUB<br />

(AC)<br />

Red 1 NO - 1 NCELB 52PP7G2U 52BP7G2U 52PP7GRU 52BP7GRU<br />

Incandescent 120V<br />

Green 1 NO - 1 NCELB 52PP7G3U 52BP7G3U 52PP7GRU 52BP7GRU<br />

Readily available items are in bold.<br />

This is a small representation of stocked items.<br />

17 CONTROL<br />

PRODUCTS<br />

1 EMERGENCY-STOP control devices according to IEC 60947-5-5<br />

Product Category: PILO<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-303


Push Buttons & Signaling Devices<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Non-Illuminated Twist-to-Release<br />

Selection Guide<br />

2 Position Twist-to-Release Devices Mushroom Head - Non-Illuminated<br />

Pilot Devices<br />

Part Number<br />

Plastic 1 3/4” Mushroom Head - Chrome<br />

Plastic 1 3/4” Mushroom Head - Black Max<br />

52 _______ R 8 W _______ _______<br />

a b c d e f 2<br />

Finish Function Style Color Contacts Part Number<br />

Chrome 2 Position Twist-to-Release Plastic 1 3/4” Mushroom Head Red 1 NO - 1 NC 52PR8W2A<br />

Black Max 2 Position Twist-to-Release Plastic 1 3/4” Mushroom Head Red 1 NO - 1 NC 52BR8W2A<br />

Chrome 2 Position Twist-to-Release Plastic 1 3/4” Mushroom Head Red None 52PR8W2<br />

Readily available items are in bold.<br />

This is a small representation of stocked items.<br />

17<br />

CONTROL<br />

PRODUCTS<br />

a<br />

Code Finish<br />

P Chrome-Command 52<br />

B<br />

Epoxy Coated-Black Max<br />

b<br />

Code Function<br />

R 2 Position Twist-to-Release, Maintained 1<br />

c<br />

Code Style<br />

8 Plastic 1 3/4” Mushroom Head<br />

d<br />

Code Lamp Type<br />

W<br />

Non-Illuminated<br />

e<br />

Code Color<br />

2 Red 1<br />

3 Green<br />

4 Yellow<br />

Z<br />

No head<br />

f 2 Code Contact Blocks<br />

A 1 NO + 1 NC 1<br />

B 2 NO + 2 NC 1<br />

C 3 NO + 3 NC 1<br />

D 4 NO + 4 NC 1<br />

E<br />

1 NC (LB)<br />

F<br />

2 NO<br />

G 2NC 1<br />

H<br />

1NO (EM)<br />

J 1 NC 1<br />

K<br />

1 NO<br />

1 EMERGENCY-STOP control devices according to IEC 60947-5-5 when<br />

provided with red operating head and positively driven NC contact blocks.<br />

Positive opening contacts according to IEC 60947-5-1, Appendix K.<br />

2 For operator without contact blocks leave position f blank.<br />

17-304<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: PILO


Push Buttons & Signaling Devices<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Illuminated Twist-to-Release<br />

Selection Guide<br />

2 Position Twist-to-Release Mushroom Head Devices - Illuminated<br />

Part Number<br />

Plastic 1 3/4” Mushroom Head - Chrome<br />

Plastic 1 3/4” Mushroom Head - Black Max<br />

52 _______ R 8 _______ _______ _______ _______<br />

a b c d e f g<br />

Pilot Devices<br />

Finish Style Voltage Bulb Type Color Contacts Part Number<br />

Chrome Plastic 1 3/4” Mushroom Head 24V LED Red 1 NO - 1 NC 52PR8DRAB<br />

Chrome Plastic 1 3/4” Mushroom Head 120V Incandescent Red 1 NO - 1 NC 52PR8ERA<br />

Chrome Plastic 1 3/4” Mushroom Head 120V LED Red 1 NO - 1 NC 52PR8GRAB<br />

Readily available items are in bold.<br />

This is a small representation of stocked items.<br />

a<br />

Code Finish<br />

P Chrome-Command 52<br />

B<br />

Epoxy Coated-Black Max<br />

b<br />

Code Function<br />

R<br />

2 Position Twist-to-Release, Maintained<br />

c<br />

Code Style<br />

8 Plastic 1 3/4” Mushroom Head<br />

d Code Operation<br />

Full Voltage 2 (AC/DC)<br />

Incandescent LED 3<br />

B 6-8V 6V<br />

C 12-13V —<br />

D 24-28V 24-28V<br />

E 120V 120V<br />

F — 240V<br />

G<br />

H<br />

J<br />

K<br />

Transformer 2<br />

120V AC<br />

240V AC<br />

480V AC<br />

600V AC<br />

e<br />

Code Color<br />

R Red 1<br />

S<br />

Green<br />

T<br />

Amber<br />

Z<br />

No head<br />

f<br />

Code Contact Blocks<br />

A 1 NO + 1 NC 1<br />

B 2 NO + 2 NC 1<br />

C 3 NO + 3 NC 1<br />

D 4 NO + 4 NC 1<br />

E 1 NC (LB)<br />

F<br />

2 NO<br />

G 2NC 1<br />

H<br />

1NO (EM)<br />

J 1 NC 1<br />

K<br />

1 NO<br />

g Code Bulb Type<br />

Blank<br />

Incandescent<br />

B<br />

LED<br />

Y Super-Bright LED 4<br />

17 CONTROL<br />

PRODUCTS<br />

1 EMERGENCY-STOP control devices according to IEC 60947-5-5 when provided with<br />

red operating head and positively driven NC contact blocks. Positive<br />

opening contacts according to IEC 60947-5-1, Appendix K, Molded bodies.<br />

2 Default bulb type is incandescent. For LED options, append field g.<br />

LED option not available on units sold “no head.”<br />

3 LED voltages apply to table g option code B and Y.<br />

6V and 120V are currently AC only. Replaced by AC/DC rated versions end of 2014.<br />

4 Not available in 240V.<br />

Product Category: PILO<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-305


Push Buttons & Signaling Devices<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Indicator Light<br />

Selection Guide<br />

Indicator Light<br />

Pilot Devices<br />

Part Number<br />

Plastic Lens<br />

Glass Lens<br />

52 _______ L _______ _______ _______ _______<br />

a b c d e f<br />

17<br />

CONTROL<br />

PRODUCTS<br />

a<br />

Code Finish<br />

P Chrome-Command 52<br />

B<br />

Epoxy Coated-Black Max<br />

b<br />

Code Type<br />

L<br />

Indicator Light<br />

c Code Style<br />

4 Plastic Lens<br />

5 Glass Lens<br />

d Code Operation<br />

Full Voltage 1 (AC/DC)<br />

Incandescent LED 2<br />

B 6-8V 6V<br />

C 12-13V —<br />

D 24-28V 24-28V<br />

E 120V 120V<br />

F — 240V<br />

Transformer 1<br />

e<br />

Code Color<br />

2 Red<br />

3 Green<br />

5 Blue<br />

7 All Colors<br />

9 Amber<br />

A<br />

Clear<br />

B<br />

White<br />

N<br />

No Lens<br />

f<br />

Code Bulb Type<br />

Blank<br />

Incandescent<br />

XB<br />

LED<br />

XY Super-Bright LED 3<br />

G<br />

H<br />

J<br />

K<br />

120V AC<br />

240V AC<br />

480V AC<br />

600V AC<br />

1 Default bulb type is incandescent. For LED options, append field f.<br />

LED option not available on units sold “No Lens”.<br />

2 LED voltages apply to table f option code XB and XY.<br />

6V, 24V (Super Bright only) and 120V are currently AC only. Replaced by AC/DC rated<br />

versions end of 2014.<br />

3 Not available in 240V.<br />

17-306<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: PILO


Push Buttons & Signaling Devices<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Indicator Lights<br />

Selection Tables<br />

Indicator Light<br />

Plastic Lens<br />

Type Lamp Type Voltage Color Chrome Black Max<br />

Red 52PL4D2XB 52BL4D2XB<br />

Green 52PL4D3XB 52BL4D3XB<br />

Full Voltage<br />

(AC/DC)<br />

Transformer<br />

(AC)<br />

LED<br />

Incandescent<br />

LED<br />

Incandescent<br />

24V<br />

120V<br />

24V<br />

120V<br />

120V<br />

480V<br />

120V<br />

240V<br />

480V<br />

Blue 52PL4D5XB 52BL4D5XB<br />

Amber 52PL4D9XB 52BL4D9XB<br />

White 52PL4DBXB 52BL4DBXB<br />

Red 52PL4E2XB 52BL4E2XB<br />

Green 52PL4E3XB 52BL4E3XB<br />

Amber 52PL4E9XB 52BL4E9XB<br />

Clear 52PL4EAXB 52BL4EAXB<br />

White 52PL4EBXB 52BL4EBXB<br />

Red 52PL4D2 52BL4D2<br />

Green 52PL4D3 52BL4D3<br />

Blue 52PL4D5 52BL4D5<br />

Amber 52PL4D9 52BL4D9<br />

White 52PL4DB 52BL4DB<br />

No Lens 52PL4DN 52BL4DN<br />

Red 52PL4E2 52BL4E2<br />

Green 52PL4E3 52BL4E3<br />

Amber 52PL4E9 52BL4E9<br />

No Lens 52PL4EN 52BL4EN<br />

Red 52PL4G2XB 52BL4G2XB<br />

Green 52PL4G3XB 52BL4G3XB<br />

Amber 52PL4G9XB 52BL4G9XB<br />

White 52PL4GBXB 52BL4GBXB<br />

Red 52PL4J2XB 52BL4J2XB<br />

Green 52PL4J3XB 52BL4J3XB<br />

White 52PL4JBXB 52BL4JBXB<br />

Red 52PL4G2 52BL4G2<br />

Green 52PL4G3 52BL4G3<br />

Amber 52PL4G9 52BL4G9<br />

White 52PL4GB 52BL4GB<br />

No Lens 52PL4GN 52BL4GN<br />

Red 52PL4H2 52BL4H2<br />

Green 52PL4H3 52BL4H3<br />

Red 52PL4J2 52BL4J2<br />

Green 52PL4J3 52BL4J3<br />

Amber 52PL4J9 52BL4J9<br />

Pilot Devices<br />

17 CONTROL<br />

PRODUCTS<br />

Readily available items are in bold.<br />

This is a small representation of stocked items.<br />

Product Category: PILO<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-307


Push Buttons & Signaling Devices<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Illuminated Push Button & Push-to-Test<br />

Selection Guide<br />

Push Button & Push-to-Test - Illuminated<br />

Pilot Devices<br />

Part Number<br />

Extended Lens<br />

Flush Lens<br />

52 _______ T _______ _______ _______ _______<br />

a b c d e f g<br />

17<br />

CONTROL<br />

PRODUCTS<br />

a<br />

Code Finish<br />

P Chrome-Command 52<br />

B<br />

Epoxy Coated-Black Max<br />

b<br />

Code Function<br />

T Illuminated Push Button / Push-to-Test 1<br />

c<br />

Code Style<br />

6 Extended Lens<br />

8 Flush Lens 2<br />

d<br />

Code Operation<br />

Full Voltage 3 (AC/DC)<br />

Incandescent LED 4<br />

B 6-8V 6V<br />

C 12-13V —<br />

D 24-28V 24-28V<br />

E 120V 120V<br />

F — 240V<br />

G<br />

H<br />

J<br />

K<br />

Transformer 3<br />

120V AC<br />

240V AC<br />

480V AC<br />

600V AC<br />

1 For push-to-test functionality, wire according to wiring diagram below.<br />

2 Products available fall 2014.<br />

e<br />

Code Color<br />

2 Red<br />

3 Green<br />

5 Blue<br />

7 All Colors<br />

9 Amber<br />

A<br />

Clear<br />

B<br />

White<br />

N<br />

No Lens<br />

f Code Contact Blocks<br />

A<br />

1 NO - 1 NC<br />

B<br />

2 NO + 2 NC<br />

C<br />

3 NO + 3 NC<br />

D<br />

4 NO + 4 NC<br />

E<br />

1 NC (LB)<br />

F<br />

2 NO<br />

G<br />

2 NC<br />

H<br />

1NO (EM)<br />

J<br />

1 NC<br />

K<br />

1 NO<br />

g<br />

Code Bulb Type<br />

Blank<br />

Incandescent<br />

B<br />

LED<br />

Y Super-Bright LED 5<br />

3 Default bulb type is incandescent. For LED options, append field g.<br />

LED option not available on units sold “No Lens”.<br />

4 LED voltages apply to table g option code B and Y.<br />

6V and 120V are currently AC only. Replaced by AC/DC rated versions end of 2014.<br />

5 Not available in 240V.<br />

17-308<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: PILO


Push Buttons & Signaling Devices<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Illuminated Push Buttons & Push-to-Test<br />

Selection Tables<br />

Push Button & Push-to-Test - Illuminated<br />

Extended Lens<br />

Type Lamp Type Voltage Color Contacts Chrome Black Max<br />

Full Voltage<br />

(AC/DC)<br />

Transformer<br />

(AC)<br />

LED<br />

Incandescent<br />

LED<br />

Incandescent<br />

Readily available items are in bold.<br />

This is a small representation of stocked items.<br />

Red 1 NO - 1 NC 52PT6D2AB 52BT6D2AB<br />

Green 1 NO - 1 NC 52PT6D3AB 52BT6D3AB<br />

24V<br />

Blue 1 NO - 1 NC 52PT6D5AB 52BT6D5AB<br />

Amber 1 NO - 1 NC 52PT6D9AB 52BT6D9AB<br />

White 1 NO - 1 NC 52PT6DBAB 52BT6DBAB<br />

120V<br />

Red 1 NO - 1 NC 52PT6E2AB 52BT6E2AB<br />

Green 1 NO - 1 NC 52PT6E3AB 52BT6E3AB<br />

Red 1 NO - 1 NC 52PT6D2A 52BT6D2A<br />

Green 1 NO - 1 NC 52PT6D3A 52BT6D3A<br />

24V<br />

Blue 1 NO - 1 NC 52PT6D5A 52BT6D5A<br />

Amber 1 NO - 1 NC 52PT6D9A 52BT6D9A<br />

White 1 NO - 1 NC 52PT6DBA 52BT6DBA<br />

120V<br />

Red 1 NO - 1 NC 52PT6E2A 52BT6E2A<br />

Green 1 NO - 1 NC 52PT6E3A 52BT6E3A<br />

Red 1 NO - 1 NC 52PT6G2AB 52BT6G2AB<br />

120V<br />

Green 1 NO - 1 NC 52PT6G3AB 52BT6G3AB<br />

Amber 1 NO - 1 NC 52PT6G9AB 52BT6G9AB<br />

White 1 NO - 1 NC 52PT6GBAB 52BT6GBAB<br />

240V<br />

Red 1 NO - 1 NC 52PT6H2AB 52BT6H2AB<br />

Green 1 NO - 1 NC 52PT6H3AB 52BT6H3AB<br />

Red 1 NO - 1 NC 52PT6G2A 52BT6G2A<br />

Green 1 NO - 1 NC 52PT6G3A 52BT6G3A<br />

120V<br />

Amber 1 NO - 1 NC 52PT6G9A 52BT6G9A<br />

White 1 NO - 1 NC 52PT6GBA 52BT6GBA<br />

No Lens 1 NO - 1 NC 52PT6GNA 52BT6GNA<br />

240V Green 1 NO - 1 NC 52PT6H3A 52BT6H3A<br />

480V Clear 1 NO - 1 NC 52PT6JAA 52BT6JAA<br />

Pilot Devices<br />

17 CONTROL<br />

PRODUCTS<br />

Product Category: PILO<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-309


Push Buttons & Signaling Devices<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Illuminated Push Button<br />

Selection Guide<br />

Push Button Mushroom Head Devices – Illuminated 4<br />

Pilot Devices<br />

Part Number<br />

Mushroom Head Metal Ø 1 3/4” Mushroom Head Plastic Ø 2 1/2” Mushroom Head Plastic Ø 1 3/4”<br />

52 _______ T 9 _______ _______ _______ _______<br />

a b c d e f g<br />

17<br />

CONTROL<br />

PRODUCTS<br />

a<br />

Code Finish<br />

P Chrome-Command 52<br />

B<br />

Epoxy Coated-Black Max<br />

b<br />

Code Type<br />

T<br />

Push Button Operator<br />

c<br />

Code Function<br />

9 2 positions – momentary in<br />

d Code Operation<br />

Full Voltage 2 (AC/DC )<br />

Incandescent LED 3<br />

B 6-8V 6V<br />

C 12-13V —<br />

D 24-28V 24-28V<br />

E 120V 120V<br />

F — 240V<br />

G<br />

H<br />

J<br />

K<br />

Transformer 2<br />

120V AC<br />

240V AC<br />

480V AC<br />

600V AC<br />

1 Positive opening according to IEC 60947-5-1, Appendix K.<br />

2 Default bulb type is incandescent. For LED options, append field g. LED option not<br />

available on units sold “no head”.<br />

3 LED voltages apply to table g option code B and Y.<br />

6V and 120V are currently AC only. Replaced by AC/DC rated versions end of 2014.<br />

4 Products available fall 2014.<br />

5 Not available in 240V.<br />

e<br />

Code Style / Color<br />

Mushroom Head Metal Ø 1 3/4” (44.5mm)<br />

2 Red 1<br />

3 Green<br />

5 Blue<br />

9 Amber<br />

A<br />

Clear<br />

B<br />

White<br />

R<br />

S<br />

T<br />

Mushroom Head Plastic Ø 1 3/4” (44.5 mm)<br />

Red<br />

Green<br />

Amber<br />

Mushroom Head Plastic Ø 2 1/2” (63.5mm)<br />

D Red 1<br />

E<br />

Green<br />

F<br />

Amber<br />

Z<br />

No Head (full voltage & transformer only)<br />

No head<br />

f<br />

Code Contact Blocks<br />

A<br />

1 NO + 1 NC<br />

B<br />

2 NO + 2 NC<br />

C<br />

3 NO + 3 NC<br />

D 4 NO + 4 NC<br />

E<br />

1 NC (LB)<br />

F 2 NO<br />

G 2 NC<br />

H<br />

1NO (EM)<br />

J<br />

1 NC<br />

K<br />

1 NO<br />

g Code Bulb Type<br />

Blank<br />

Incandescent<br />

B<br />

LED<br />

Y Super-Bright LED 5<br />

17-310<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: PILO


Push Buttons & Signaling Devices<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Illuminated Selector Switches<br />

Selection Guide<br />

Selector Switches – Illuminated<br />

Part Number<br />

Short Lever – Chrome<br />

Short Lever – Black Max<br />

52 S ______ 7 _____ _____ _____ _____ _____ _____<br />

a b c d e f g h i<br />

Pilot Devices<br />

Finish Style Cam Type Function Color Contacts Part Number<br />

Chrome Maintained 2 Position: CAM A 24-28V AC/DC No Insert None 52SA7ADN<br />

Chrome Maintained 2 Position: CAM A 120V AC (Transformer) No Insert None 52SA7AGN<br />

Chrome Maintained 3 Position: CAM C 120V AC No Insert None 52SA7CGN<br />

Readily available items are in bold.<br />

This is a small representation of stocked items.<br />

a<br />

Code Type<br />

S<br />

Selector Switch<br />

b<br />

Code Finish<br />

A Chrome - Command 52<br />

X<br />

Epoxy Coated - Black Max<br />

f<br />

Code Color<br />

2 Red<br />

3 Green<br />

5 Blue<br />

9 Amber<br />

A<br />

Clear<br />

N<br />

No Insert<br />

c<br />

Code Style<br />

7 Maintained<br />

d<br />

Code Function<br />

A<br />

2 Position: CAM A<br />

B<br />

3 Position: CAM B<br />

C<br />

3 Position: CAM C<br />

e Code Operation<br />

Full Voltage 1 (AC/DC )<br />

Incandescent LED 2<br />

B 6-8V 6V<br />

C 12-13V —<br />

D 24-28V 24-28V<br />

E 120V 120V<br />

F — 240V<br />

G<br />

H<br />

J<br />

K<br />

Transformer 1<br />

120V AC<br />

240V AC<br />

480V AC<br />

600V AC<br />

g<br />

Code Contact Blocks<br />

A<br />

1 NO - 1 NC<br />

E<br />

1 NC (LB)<br />

H<br />

1 NO (EM)<br />

J<br />

1 NC<br />

K<br />

1 NO<br />

h Code Contact Quantity & Location<br />

A CAM & C CAM<br />

Left<br />

B CAM<br />

Right<br />

0 1 —<br />

1 — 1<br />

3 2 —<br />

4 — 2<br />

i Code Bulb Type<br />

Blank<br />

Incandescent<br />

B<br />

LED<br />

Y Super-Bright LED 3<br />

17 CONTROL<br />

PRODUCTS<br />

1 Default bulb type is incandescent. For LED options, append field i.<br />

LED option not available on units sold “no head”.<br />

2 LED voltages apply to table i option code B and Y.<br />

6V and 120V are currently AC only. Replaced by AC/DC rated versions end of 2014.<br />

3 Not available in 240V. For CAM selection see page 17-319.<br />

Product Category: PILO<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-311


Push Buttons & Signaling Devices<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Non-Illuminated Selector Switch<br />

Selection Guide<br />

Selector Switch – Non-Illuminated<br />

Short Lever<br />

Long Lever<br />

Pilot Devices<br />

Part Number<br />

52 S ______ 2 ______ ______ ______ ______ ______<br />

a b c d e f g 2 h 2<br />

17<br />

CONTROL<br />

PRODUCTS<br />

a<br />

Code Type<br />

S<br />

Selector Switch<br />

b<br />

Code Finish<br />

A<br />

Chrome - Short Lever<br />

B<br />

X<br />

W<br />

Chrome - Long Lever<br />

BlackMax - Short Lever<br />

BlackMax - Long Lever<br />

c<br />

Code Style<br />

2 Non-Illuminated<br />

d Code Function<br />

A<br />

2 Position: CAM A<br />

B<br />

3 Position: CAM B<br />

C 3 Position: CAM C 1<br />

D<br />

E<br />

G<br />

H<br />

3 Position: CAM D<br />

3 Position: CAM E<br />

3 Position: CAM G<br />

4 Position: CAM H<br />

e Code Type<br />

2 Position<br />

Maintained Spring Return<br />

A All —<br />

C Left Right<br />

3 Position<br />

Maintained Spring Return<br />

A All —<br />

B Center, Right Left<br />

C Center, Left Right<br />

D Center Left, Right<br />

f<br />

Code Color<br />

2 Red<br />

3 Green<br />

4 Yellow<br />

5 Blue<br />

6 Gray<br />

8 Orange<br />

B<br />

White<br />

N<br />

No Insert (Black)<br />

g 2 Code Contact Blocks<br />

A<br />

1 NO - 1 NC<br />

E<br />

1 NC (LB)<br />

H<br />

1 NO (EM)<br />

J<br />

1 NC<br />

K<br />

1 NO<br />

2<br />

h<br />

Code Contact Quantity & Location<br />

Left<br />

Right<br />

0 1 —<br />

1 — 1<br />

2 1 1<br />

3 2 —<br />

4 — 2<br />

5 2 1<br />

6 1 2<br />

7 2 2<br />

8 3 —<br />

9 — 3<br />

4 Position<br />

Maintained Position Spring Return<br />

A All —<br />

1 C CAM on spring return selectors is limited to 4 contact blocks.<br />

For CAM selection see page 17-319.<br />

2 For operator without contact blocks leave positions g and h blank.<br />

17-312<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: PILO


Push Buttons & Signaling Devices<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Non-Illuminated Selector Switch<br />

Selector Switch, Non-Illuminated 1)<br />

Switch Position Type Chrome Black Max<br />

Contact Type Contact Left Right<br />

No Contacts — — —<br />

1 N.O. A O X<br />

M = Maintained<br />

S = Spring Return Short Lever Long Lever Short Lever Long Lever<br />

2-Position Operator<br />

M M 52SA2AAB 52SB2AAB 52SX2AAB 52SW2AAB<br />

M


Push Buttons & Signaling Devices<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Revised on 04/30/18<br />

Keyed Selector Switch<br />

Selection Guide<br />

Keyed Selector Switch<br />

Part Number<br />

52 S C ______ ______ ______ ______ ______ ______<br />

a b c d e f 3 g 3 h<br />

Pilot Devices<br />

17<br />

a<br />

Code Type<br />

S<br />

Selector Switch<br />

b<br />

Code Finish<br />

C Chrome – Command 52<br />

c<br />

Code Style<br />

5 Non-Standard Lock/Key 1a<br />

6 Standard Lock/Key<br />

d<br />

Code Function<br />

A<br />

2 Position: CAM A<br />

B<br />

3 Postion: CAM B<br />

C 3 Postion: CAM C 2<br />

D<br />

3 Postion: CAM D<br />

E<br />

3 Postion: CAM E<br />

G<br />

3 Postion: CAM G<br />

H<br />

4 Postion: CAM H<br />

e Code Lock Type<br />

Maintained /<br />

Spring Return<br />

2 Position<br />

Key Removal<br />

Left<br />

Right<br />

E All Maintained X X<br />

F All Maintained X —<br />

G All Maintained — X<br />

X Spring from Right X —<br />

f 3 Code Contact Blocks<br />

A<br />

1 NO - 1 NC<br />

J<br />

1 NC<br />

K<br />

1 NO<br />

E<br />

1 NC (LB)<br />

H<br />

1 NO (EM)<br />

g 3 Code Contact Quantity & Location<br />

Left<br />

Right<br />

0 1 —<br />

1 — 1<br />

2 1 1<br />

3 2 —<br />

4 — 2<br />

5 2 1<br />

6 1 2<br />

7 2 2<br />

8 3 —<br />

9 — 3<br />

h Code Key Type 1b<br />

Blank<br />

501CH<br />

X298<br />

550CH<br />

X299<br />

549CH<br />

X300<br />

548CH<br />

X301<br />

547CH<br />

X302<br />

506CH<br />

CONTROL<br />

PRODUCTS<br />

Maintained<br />

Position<br />

Spring<br />

Return<br />

3 Position<br />

Key Removal<br />

Left Center Right<br />

E All — X X X<br />

F All — X — —<br />

G All — — — X<br />

H All — — X —<br />

J All — X — X<br />

K All — X X —<br />

M All — — X X<br />

T Center, Right Left — X —<br />

U Left, Center Right — X —<br />

V Center Left, Right — X —<br />

W Center, Right Left — — X<br />

Y Center, Right Left — X X<br />

Z Left, Center Right X X X<br />

Maintained<br />

Position<br />

4 Position<br />

Key Removal<br />

Left Left Center Right Center Right<br />

E All X X X X<br />

F All X — — —<br />

G All — — — X<br />

Standard Lock/Key<br />

1a. See page 17-316 for replacement keys, and up-to 15<br />

additional uniquely keyed M - Series Lock Options available<br />

for use with the 52SC6 key-operated selector switches.<br />

1b. To order the specific lock types shown in table h, simply<br />

append the corresponding “X” suffix to a standard part<br />

number (Ordering Example: 52SC6AEX298).<br />

Note: Same list price applies as standard keyed locks.<br />

2. C CAM on spring return selectors is limited to 4 contact blocks.<br />

For CAM selection see page 17-319.<br />

3 For operator without contact blocks leave positions f and g<br />

blank.<br />

17-314<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: PILO


Push Buttons & Signaling Devices<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Keyed Selector Switch<br />

Key-operated Selector Switch, Non-Illuminated 1)<br />

Switch Position Type Key Removal<br />

M = Maintained<br />

Contact Type Contact Left Right S = Spring Return Left Both<br />

2-Position Operator<br />

No Contacts — — —<br />

M M 52SC6AF 52SC6AE<br />

M


Push Buttons & Signaling Devices<br />

Actuators and Indicators, Customized Designs<br />

Revised on 04/30/18<br />

Special locks Switch<br />

Options<br />

Pilot Devices<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Special locks for key-operated switches<br />

Siemens Key-Operated Selector Switches beginning with 51SA6<br />

or 52SC6 can be optionally ordered with the 15 uniquely keyed<br />

M-Series Locks by appending the corresponding "X" suffixes<br />

from the table below to the catalog number. (Ordering Example<br />

for Lock Number M705: 52SC6CEX705).<br />

Note: Pricing for M - Series Locks on this page are slightly higher<br />

than standard lock types.<br />

Suffix Code<br />

X705<br />

X709<br />

X713<br />

X714<br />

X715<br />

X723<br />

X725<br />

X738<br />

X749<br />

X750<br />

X757<br />

X766<br />

X779<br />

X782<br />

X795<br />

Lock Number<br />

M705<br />

M709<br />

M713<br />

M714<br />

M715<br />

M723<br />

M725<br />

M738<br />

M749<br />

M750<br />

M757<br />

M766<br />

M779<br />

M782<br />

M795<br />

Spare Keys for Key-Operated Selector Switches<br />

Spare Key<br />

Part Number<br />

550CH (1 Key)<br />

52KEY-550CH<br />

549CH (1 Key)<br />

52KEY-549CH<br />

548CH (1 Key)<br />

52KEY-548CH<br />

547CH (1 Key)<br />

52KEY-547CH<br />

501CH (1 Key)<br />

52KEY-501CH<br />

506CH (1 Key)<br />

52KEY-506CH<br />

M703 (1 Key)<br />

52KEY-M703<br />

M705 (1 Key)<br />

52KEY-M705<br />

M706 (1 Key)<br />

52KEY-M706<br />

M709 (1 Key)<br />

52KEY-M709<br />

M712 (1 Key)<br />

52KEY-M712<br />

M713 (1 Key)<br />

52KEY-M713<br />

M714 (1 Key)<br />

52KEY-M714<br />

M715 (1 Key)<br />

52KEY-M715<br />

M716 (1 Key)<br />

52KEY-M716<br />

M717 (1 Key)<br />

52KEY-M717<br />

M723 (1 Key)<br />

52KEY-M723<br />

M725 (1 Key)<br />

52KEY-M725<br />

M728 (1 Key)<br />

52KEY-M728<br />

M730 (1 Key)<br />

52KEY-M730<br />

M735 (1 Key)<br />

52KEY-M735<br />

M736 (1 Key)<br />

52KEY-M736<br />

M738 (1 Key)<br />

52KEY-M738<br />

M747 (1 Key)<br />

52KEY-M747<br />

M749 (1 Key)<br />

52KEY-M749<br />

M750 (1 Key)<br />

52KEY-M750<br />

M752 (1 Key)<br />

52KEY-M752<br />

M753 (1 Key)<br />

52KEY-M753<br />

M756 (1 Key)<br />

52KEY-M756<br />

M757 (1 Key)<br />

52KEY-M757<br />

M759 (1 Key)<br />

52KEY-M759<br />

M766 (1 Key)<br />

52KEY-M766<br />

M769 (1 Key)<br />

52KEY-M769<br />

M771 (1 Key)<br />

52KEY-M771<br />

M779 (1 Key)<br />

52KEY-M779<br />

M784 (1 Key)<br />

52KEY-M784<br />

M790 (1 Key)<br />

52KEY-M790<br />

M795 (1 Key)<br />

52KEY-M795<br />

M700 (1 Key)<br />

52KEY-M700<br />

M701 (1 Key)<br />

52KEY-M701<br />

M702 (1 Key)<br />

52KEY-M702<br />

M704 (1 Key)<br />

52KEY-M704<br />

M705 (1 Key)<br />

52KEY-M705<br />

M707 (1 Key)<br />

52KEY-M707<br />

M711 (1 Key)<br />

52KEY-M711<br />

M713 (1 Key)<br />

52KEY-M713<br />

M715 (1 Key)<br />

52KEY-M715<br />

M782 (1 Key)<br />

52KEY-M782<br />

M795 (1 Key)<br />

52KEY-M795<br />

17-316<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Push Buttons & Signaling Devices<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Selector Push Button<br />

Selection Guide<br />

Selector Push Button<br />

Part Number<br />

52 S A ______ ______ ______ ______<br />

a b c d e f 1<br />

Finish Style Function Color Contacts Part Number<br />

Chrome Flush Selector Push Button 2 Position CAM Q Black None 52SA3Q1<br />

Chrome Flush Selector Push Button 2 Position CAM R Black None 52SA3R1<br />

Chrome Flush Selector Push Button 2 Position CAM P Black None 52SA3P1<br />

Readily available items are in bold.<br />

This is a small representation of stocked items.<br />

Selector Push Buttons<br />

Pilot Devices<br />

a<br />

Code Type<br />

S<br />

Selector Push Buttons<br />

b<br />

Code Finish<br />

A Chrome - Command 52<br />

c<br />

Code Style<br />

3 Flush Button<br />

4 Extended Button - 1/2”<br />

d<br />

Code Function<br />

P<br />

2 Position: CAM P<br />

Q<br />

2 Position: CAM Q<br />

R<br />

2 Position: CAM R<br />

S<br />

3 Position: CAM S<br />

e<br />

Code Color<br />

1 Black<br />

2 Red<br />

f<br />

1 Code Contact Blocks<br />

CAM P (2 Selector Position)<br />

Left Center Right Contact Mounting<br />

N D N/A N/A N D<br />

Blocks Position<br />

J0 X O — — O O NC Left<br />

K0 O X — — X X NO Left<br />

CAM Q (2 Selector Position)<br />

Left Center Right Contact Mounting<br />

N D N/A N/A N D Blocks Position<br />

J0 X X — — O O NC Left<br />

J1 X O — — O O NC Right<br />

K0 O O — — O X NO Left<br />

K1 O X — — O X NO Right<br />

17 CONTROL<br />

PRODUCTS<br />

CAM R (2 Selector Position)<br />

Left Center Right Contact Mounting<br />

N D N/A N/A N D Blocks Position<br />

J0 X X — — X O NC Left<br />

J1 X O — — X X NC Left<br />

K0 O O — — O X NO Right<br />

K1 O X — — O O NO Right<br />

CAM S (3 Selector Position)<br />

Left Center Right Contact Mounting<br />

N D N D N D<br />

Blocks Position<br />

J0 X O O O O O NC Left<br />

J1 X O X X O O NC Right<br />

K0 O O O X O X NO Left<br />

K1 O X O O O X NO Right<br />

Note: X = Closed / O = Open<br />

1 For operator without contact blocks leave position f blank<br />

Product Category: PILO<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-317


Pushbutton Units and Indicator Lights<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Special devices<br />

Selection and ordering data<br />

Version Ohms / color Order no. Pack<br />

Pilot Devices<br />

Potentiometer operator 50 52MA3B01 1<br />

2 Watts, 500 V AC/DC (NEMA Type 4) 150 52MA3B03<br />

250 52MA3B04<br />

500 52MA3B06<br />

750 52MA3B07<br />

1 K 52MA3B08<br />

2.5 K 52MA3B10<br />

5 K 52MA3B12<br />

10 K 52MA3B14<br />

15 K 52MA3B15<br />

25 K 52MA3B16<br />

50 K 52MA3B18<br />

100 K 52MA3B20<br />

150 K 52MA3B21<br />

250 K 52MA3B22<br />

500 K 52MA3B24<br />

1 M 52MA3B26<br />

1.5 M 52MA3B27<br />

2 M 52MA3B28<br />

5 M 52MA3B31<br />

Unit<br />

2 Button maintained operator black (flush) / red (flush) 52MP2A1A2 1<br />

black (flush) / red (extended) 52MP2A1B2<br />

black (flush) / yellow (mushroom) 52MP2A1W4<br />

green (flush) / red (flush)<br />

52MP2A3A2<br />

green (flush) / red (extended) 52MP2A3B2<br />

green (flush) / red (mushroom) 52MP2A3W2<br />

green (flush) / green (mushroom) 52MP2A3W3<br />

Button remains depressed when pushed less caps 52MP2<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Wobble stick 2.5” operator<br />

For use with 52BAJ (NC) contact block red 52ABW2 1<br />

green<br />

52ABW3 <br />

grey<br />

52ABW6 <br />

Maintained toggle operator 52ABT 1<br />

For use with 52BAJ (NC) contact block<br />

17-318<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Pushbutton Units and Indicator Lights<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Cam selection<br />

Selection and ordering data<br />

Non-illuminated and keyed selector switches (viewed from front)<br />

2 Selector Positions Contact Blocks CAM Mounting<br />

Left<br />

Right<br />

Left Right<br />

X<br />

O<br />

NC (52BAJ)<br />

A<br />

L or R<br />

O<br />

X<br />

NO (52BAK)<br />

A<br />

L or R<br />

3 Selector Positions Contact Blocks CAM Mounting<br />

Left Center Right Left Right<br />

X<br />

O<br />

O<br />

NO (52BAK)<br />

B<br />

R<br />

O<br />

O<br />

X<br />

NO (52BAK)<br />

B<br />

L<br />

X<br />

X<br />

O<br />

NC (52BAJ)<br />

B<br />

L<br />

O<br />

X<br />

X<br />

NC (52BAJ)<br />

B<br />

R<br />

X<br />

O<br />

X<br />

2NO (2-52BAK)<br />

B<br />

L and R<br />

X<br />

O<br />

O<br />

NC (52BAJ)<br />

C<br />

L or R<br />

O<br />

O<br />

X<br />

NO (52BAK)<br />

C<br />

L or R<br />

O<br />

X<br />

O<br />

NC (52BAJ)<br />

D<br />

L or R<br />

O<br />

O<br />

X<br />

NO (52BAK)<br />

D<br />

L or R<br />

X<br />

O<br />

O<br />

NO (52BAK)<br />

E<br />

L or R<br />

O<br />

X<br />

O<br />

NC (52BAJ)<br />

E<br />

L or R<br />

X<br />

O<br />

O<br />

NC (52BAJ)<br />

G<br />

L<br />

O<br />

X<br />

O<br />

NC (52BAJ)<br />

G<br />

R<br />

O<br />

O<br />

X<br />

NO (52BAK)<br />

G<br />

L or R<br />

4 Selector Positions Contact Blocks CAM Mounting<br />

Left Left Center Right Center Right Left Right<br />

X O<br />

O<br />

O NO (52BAK)<br />

H<br />

R<br />

O X<br />

O<br />

O NC (52BAJ)<br />

H<br />

L<br />

O O<br />

X<br />

O NC (52BAJ)<br />

H<br />

R<br />

O O<br />

O<br />

X NO (52BAK)<br />

H<br />

L<br />

Illuminated selector switches (viewed from front)<br />

Selector Pushbuttons (viewed from front)<br />

Ordering Information<br />

• Contact blocks are ordered separately, see page 17-319<br />

• Determine which table to use based upon the type of selector (non-illum selector switch-top, illum<br />

selector switch-middle, and selector pushbutton-bottom).<br />

• Find the correct number of selector positions (2, 3 or 4 positions).<br />

• Select the contact operation required for each selector position. X indicates the contacts are closed,<br />

while O indicates the contacts are open. (For the selector pushbutton, N=normal and D=depressed).<br />

Contact block must be assembled in position shown for each circuit application.<br />

• Identify the CAM letter required for the chosen contact operation (only 1 CAM can be used per selector<br />

switch or selector pushbutton).<br />

• Contact blocks must be assembled in the position shown for each circuit application. The mounting<br />

position is viewed from the front of the device.<br />

Ordering CAMs D, E or G<br />

• CAM D, E or G may be ordered at the same price by changing the 6th character of the selector catalog<br />

number. Example: Selector with D cam 52SX2DAB.<br />

Size Requirements<br />

• C CAM on spring return selectors is limited to 4 contact blocks.<br />

• Selector operators in enclosures are limited to depth of 1 contact block. (2 blocks wide).<br />

2 Selector Positions Contact Blocks CAM Mounting<br />

Left<br />

Right<br />

Left Right<br />

X<br />

O<br />

NC (52BAJ)<br />

A<br />

L<br />

O<br />

X<br />

NO (52BAK)<br />

A<br />

L<br />

3 Selector Positions Contact Blocks CAM Mounting<br />

Left Center Right Left Right<br />

O<br />

O<br />

X<br />

NC (52BAJ)<br />

B<br />

R<br />

O<br />

X<br />

O<br />

NO (52BAK)<br />

B<br />

R<br />

X<br />

O<br />

O<br />

NC (52BAJ)<br />

C<br />

L<br />

O<br />

O<br />

X<br />

NO (52BAK)<br />

C<br />

L<br />

2 Selector Positions Contact Blocks CAM Mounting<br />

Left<br />

Right<br />

Left Right<br />

N D N D<br />

X O<br />

O O<br />

NC (52BAJ)<br />

Q<br />

R<br />

X X<br />

O O<br />

NC (52BAJ)<br />

Q<br />

L<br />

O X<br />

O X<br />

NO (52BAK)<br />

Q<br />

R<br />

O O<br />

O X<br />

NO (52BAK)<br />

Q<br />

L<br />

X O<br />

O O<br />

NC (52BAJ)<br />

P<br />

L or R<br />

O X<br />

X X<br />

NO (52BAK)<br />

P<br />

L or R<br />

X X<br />

X O<br />

NC (52BAJ)<br />

R<br />

L<br />

X O<br />

X X<br />

NC (52BAJ)<br />

R<br />

R<br />

O X<br />

O O<br />

NO (52BAK)<br />

R<br />

R<br />

O O<br />

O X<br />

NO (52BAK)<br />

R<br />

L<br />

3 Selector Positions Contact Blocks CAM Mounting<br />

Left<br />

Center Right<br />

Left Right<br />

N D N D N D<br />

X O O O O O<br />

NC (52BAJ)<br />

S<br />

L<br />

X O X X O O<br />

NC (52BAJ)<br />

S<br />

R<br />

O X O O O X<br />

NO (52BAK)<br />

S<br />

R<br />

O O O X O X<br />

NO (52BAK)<br />

S<br />

L<br />

Pilot Devices<br />

17 CONTROL<br />

PRODUCTS<br />

Product Category: PILO<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-319


Pushbutton Units and Indicator Lights<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Custom selector switch designs<br />

Selection and ordering data<br />

Assembled Non-illuminated Selector Switches<br />

• Determine contact block and location from above.<br />

• Select block suffix. Ex: J = 52BAJ.<br />

• Now select position suffix.<br />

• 1-52BAJ block mounted on right side, suffix will be J 1.<br />

• Additional suffixes allow for multiple quantities and locations.<br />

• Repeat process for next block if required.<br />

• Add list price of blocks to operator list price.<br />

• Consult factory for delivery.<br />

Pilot Devices<br />

CONTROL<br />

PRODUCTS<br />

17<br />

Example 1: X O O Block Suffix Position Suffix<br />

O O X<br />

Quantity and Location<br />

HAND-OFF-AUTO Maintained Switch A = 1 NO - 1 NC, 52BJK Suffix Left Right<br />

Catalog No 52SA2CAB A 1 = 52A2CABA1 E = NC Late Break, 52BAE 0 1 —<br />

(52BJK block mounted on right side) H = NO Early Make, 52BAH 1 — 1<br />

J = NC, 52BAJ 2 1 1<br />

Example 2: X O O 52BAJ (L) K = NO, 52BAK 3 2 —<br />

O X O 52BAJ (R) 4 — 2<br />

O O X 52BAK (L or R) }K1 5 2 1<br />

G Cam required 6 1 2<br />

Catalog No 52SA2GAB J2 K1 = 52SA2GABJ2K1 7 2 2<br />

8 3 —<br />

9 — 3<br />

17-320<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: PILO


Pushbutton Units and Indicator Lights<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Accessories and spare parts<br />

Selection and ordering data<br />

Version Suitable for Color Order no.<br />

Flush actuator lens cap<br />

The 52RC1 Screw-on style caps shown ­<br />

are used on the new 52BM8 & 52PM8 ­<br />

Pushbutton Operators. To order Snap-on ­<br />

style replacement caps for the old style 52PA8 ­<br />

& 52PX8 Pushbutton Operators change the ­<br />

4th character from “C” to “A” (i.e. 52RA1A1).<br />

For flush type, ­<br />

non-illuminated pushbuttons ­<br />

bag of 5 caps<br />

black<br />

red<br />

green<br />

yellow<br />

blue<br />

gray<br />

orange<br />

kit- all colors<br />

52RC1A1<br />

52RC1A2<br />

52RC1A3<br />

52RC1A4<br />

52RC1A5<br />

52RC1A6<br />

52RC1A8<br />

52RC1AN<br />

Extended actuator lens cap<br />

The 52RC1 Screw-on style caps shown ­<br />

are used on the new 52BM8 & 52PM8 ­<br />

Pushbutton Operators. To order Snap-on ­<br />

style replacement caps for the old style 52PA8 ­<br />

& 52PX8 Pushbutton Operators change the<br />

4th character from “C” to “A” (i.e. 52RA1B1).<br />

For extended type, ­<br />

non-illuminated pushbuttonsbag<br />

of 5 caps<br />

black<br />

52RC1B1<br />

red<br />

52RC1B2<br />

green<br />

52RC1B3<br />

yellow<br />

52RC1B4<br />

blue<br />

52RC1B5<br />

gray<br />

52RC1B6<br />

orange<br />

52RC1B8<br />

1 of each color cap 52RC1BN<br />

Pilot Devices<br />

Mushroom head cap - Plastic<br />

set-screw type<br />

replacement caps are for discontinued ­<br />

52PB9 and 52PX9 operators only<br />

For large 2 1/2”(63.5mm) type, ­<br />

set screw non-illuminated ­<br />

mushroom pushbuttons<br />

For small 1 5/8”(41.3mm) type, ­<br />

non-illuminated mushroom ­<br />

pushbuttons<br />

black<br />

52RB3E1<br />

red<br />

52RB3E2<br />

green<br />

52RB3E3<br />

yellow<br />

52RB3E4<br />

blue<br />

52RB3E5<br />

gray<br />

52RB3E6<br />

orange<br />

52RB3E8<br />

1 kit of each color cap 52RB3EN<br />

black<br />

52RB3D1<br />

red<br />

52RB3D2<br />

green<br />

52RB3D3<br />

yellow<br />

52RB3D4<br />

blue<br />

52RB3D5<br />

gray<br />

52RB3D6<br />

orange<br />

52RB3D8<br />

1 of each color cap 52RB3DN<br />

Mushroom head cap - Metal<br />

set-screw type<br />

For small 1 5/8”(41.3mm) type, ­<br />

set screw non-illuminated ­<br />

mushroom pushbuttons<br />

chrome<br />

red<br />

green<br />

52RB3FC<br />

52RB3F2<br />

52RB3F3<br />

Replacement Lens for Indicator Lights For catalog numbers starting ­<br />

with 52PL or 52BL red 52RA4S2<br />

Plastic green 52RA4S3<br />

blue<br />

52RA4S5<br />

amber<br />

52RA4S9<br />

clear<br />

52RA4SA<br />

white<br />

52RA4SB<br />

1 of each color 52RA4SN<br />

Glass red 52RA4T2<br />

green<br />

52RA4T3<br />

blue<br />

52RA4T5<br />

amber<br />

52RA4T9<br />

clear<br />

52RA4TA<br />

white<br />

52RA4TB<br />

1 of each color 52RA4TN<br />

Replacement Lens forPush to Test/ For catalog numbers starting<br />

Illuminated Pushbuttons<br />

with 52PT or 52BT red 52RA5S2<br />

The 52RA5S Raised lens caps shown are used<br />

on the 52BT6 & 52PT6 PTT/Illuminated<br />

Plastic green 52RA5S3<br />

Pushbutton Operators. To order Flush lens caps<br />

blue<br />

52RA5S5<br />

for the new style 52BT8 & 52PT8 PTT/<br />

amber<br />

52RA5S9<br />

Illuminated Pushbutton Operators change the<br />

clear<br />

52RA5SA<br />

52RA5S prefix to 52RC5P (i.e. 52RC5P2).<br />

white<br />

52RA5SB<br />

17 CONTROL<br />

PRODUCTS<br />

To order replacement lens for indicator lights starting with 52PA, 52PE, or<br />

52PX, change the 6th digit to P for plastic and G for glass.<br />

It is possible to retrofit catalog numbers starting with 52PA, 52PE and 52PX<br />

with the replacement lens. The new lens have concentric ribs for improved<br />

light distribution.<br />

To order replacement lens for push to test / illuminated pushbuttons starting<br />

with 52PA, 52PE, or 52PX, change the 6th digit to a P.<br />

Product Category: PILO<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-321


Pushbutton Units and Indicator Lights<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Accessories and spare parts<br />

Selection and ordering data<br />

Version Suitable for Color Order no.<br />

Pilot Devices<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Mushroom head push pull<br />

illuminated plastic<br />

screw-on type<br />

Mushroom head push pull<br />

illuminated metal<br />

screw-on type<br />

Mushroom head push pull<br />

non-illuminated plastic<br />

screw-on type<br />

Mushroom head push pull<br />

non-illuminated metal<br />

screw-on type<br />

Twist to release head<br />

illuminated plastic<br />

screw-on type<br />

Twist to release head<br />

non-illuminated plastic<br />

screw-on type<br />

For small 1 3/4” type, push-pull units red 52RC3JR<br />

green<br />

52RC3JS<br />

amber<br />

52RC3JT<br />

For large 2 1/2” type, push-pull units red 52RC3KR<br />

green<br />

52RC3KS<br />

amber<br />

52RC3KT<br />

Chrome, for small 1 3/4” type, push-pull<br />

units<br />

BlackMax, for small 1 3/4” type, push-pull<br />

units<br />

red<br />

green<br />

amber<br />

white<br />

red<br />

green<br />

amber<br />

white<br />

52RB3H2<br />

52RB3H3<br />

52RB3H9<br />

52RB3HB<br />

52RX3H2<br />

52RX3H3<br />

52RX3H9<br />

52RX3HB<br />

For small 1 3/4” type, push-pull units<br />

black 52RC3D1<br />

52BP, 52PM9 or 52BM9) green<br />

52RC3D3<br />

(catalog numbers starting with 52PP,<br />

red<br />

52RC3D2<br />

yellow<br />

52RC3D4<br />

blue<br />

52RC3D5<br />

gray<br />

52RC3D6<br />

orange 52RC3D8<br />

1 of each color 52RC3DN<br />

For large 2 1/2” type, push-pull units<br />

black 52RC3E1<br />

(catalog numbers starting with 52PP,<br />

red<br />

52RC3E2<br />

52BP, 52PM9 or 52BM9) green<br />

52RC3E3<br />

yellow<br />

52RC3E4<br />

blue<br />

52RC3E5<br />

gray<br />

52RC3E6<br />

orange 52RC3E8<br />

1 of each color 52RC3EN<br />

For small 1 3/4” type, push-pull units<br />

red 52RC3F2<br />

52BP) chrome 52RC3FC<br />

(catalog numbers starting with 52PP or<br />

green<br />

52RC3F3<br />

For small twist to release units red 52RC3RR<br />

green<br />

52RC3RS<br />

amber<br />

52RC3RT<br />

For small twist to release units red 52RC3R2<br />

green<br />

52RC3R3<br />

yellow<br />

52RC3R4<br />

Replacement lens kit for red 52RA6P2<br />

Illuminated selector switches<br />

green<br />

52RA6P3<br />

(Knob with Insert)<br />

blue<br />

52RA6P5<br />

amber<br />

52RA6P9<br />

clear<br />

52RA6PA<br />

white<br />

52RA6PB<br />

Lever inserts red 52RA2A2<br />

Short lever green 52RA2A3<br />

yellow<br />

52RA2A4<br />

blue<br />

52RA2A5<br />

gray<br />

52RA2A6<br />

orange 52RA2A8<br />

white<br />

52RA2AB<br />

Long lever red 52RA2B2<br />

green<br />

52RA2B3<br />

yellow<br />

52RA2B4<br />

blue<br />

52RA2B5<br />

gray<br />

52RA2B6<br />

orange 52RA2B8<br />

white<br />

52RA2BB<br />

For push-pull units whose catalog numbers that start with 52PX, 52PA or 52PE, replacement heads are available.<br />

Order from the 52RB type “Mushroom head pushbutton cap” section on page 17-319.<br />

17-322<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: PILO


Pushbutton Units and Indicator Lights<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Accessories and spare parts<br />

Selection and ordering data<br />

Version Suitable for Color Order no.<br />

Protective boot Flush pushbutton operations clear 52AABA<br />

Offers protection from ice and foreign sub-<br />

black<br />

52AAB1<br />

stances from interfering with button operation<br />

Guards Non-illuminated basic pushbuttons chrome 52AAGP<br />

Prevents accidental operation blackmax 52AXGP<br />

1 5/8” mushroom pushbuttons, 1 3/4”<br />

chrome<br />

52AAGM<br />

push-pull units , and twist to release units blackmax 52AXGM<br />

Push to test/illuminated pushbutton and<br />

chrome<br />

52AAGL<br />

indicator lights<br />

blackmax 52AXGL<br />

EMERGENCY-STOP Lock Out<br />

Class 52 Illuminated Mushroom Head<br />

Pushbuttons; 304 Stainless Steel<br />

chrome (304 SS)<br />

52AALE<br />

EMERGENCY-STOP Backing Ring Yellow 90mm E-STOP Backing Ring 52AAR<br />

Pilot Devices<br />

Locknuts Non-illuminated basic pushbuttons chrome 52AANP<br />

Replacement front ring blackmax 52AXNP<br />

Non-illuminated mushroom pushbuttons chrome 52AANL<br />

blackmax 52AXNL<br />

Push-pull and twist-to-release units (only for chrome 52CANP<br />

push-pull units starting with 52PP or 52BP) blackmax 52CXNP<br />

Indicator Lights blue 52AANL<br />

amber<br />

52AXNL<br />

Selector switches chrome 52AANS<br />

blackmax 52AXNS<br />

Mounting Accessories Class 52 Trim Washer Kit (Set of 10 pcs) chrome 52AAQ<br />

Class 52 Washer Kit (Include 2-Neoprene<br />

Gaskets, 1-Trim Washer, 1-Index Locking Ring<br />

(chrome)<br />

52AAD<br />

Padlock attachments Non-illuminated basic pushbuttons flush 52AALA<br />

extended 52AALB<br />

Padlock cover<br />

Pushbuttons, selector switches, and<br />

52AALS<br />

Lock devices in off position<br />

non-illuminated mushroom heads<br />

Lock nut wrench All devices 52MAWB<br />

Hole plugs corrosion resistant 52AAH6<br />

steel, grey 52ABH6<br />

stainless steel 52ABHS<br />

Spare keys Class 52 Standard Keyed Selector Switch. 501CH 52KEY-501CH<br />

(Kit includes 1 Key) Keyed Selector Switch ordered with Suffix X302. 506CH 52KEY-506CH<br />

Keyed Selector Switch ordered with Suffix X301. 547CH 52KEY-547CH<br />

Keyed Selector Switch ordered with Suffix X300. 548CH 52KEY-548CH<br />

Keyed Selector Switch ordered with Suffix X299. 549CH 52KEY-549CH<br />

Keyed Selector Switch ordered with Suffix X298. 550CH 52KEY-550CH<br />

17 CONTROL<br />

PRODUCTS<br />

Grounding kit All devices 52AL109145<br />

Touchsafe contact blocks with gold flashing<br />

52 BAJ<br />

52 BAK<br />

52 BAR<br />

1 NO 52BAK<br />

1 NC 52BAJ <br />

1 NO - 1 NC 52BJK <br />

1 NO early make closes before 52BAK 52BAH<br />

1 NC late break opens after 52 BAJ 52BAE<br />

1 NO - 1 NC Reed switch; UL listed for class 1 division 2;<br />

52BAR <br />

.25A Max, 200V AC, 10 Watt max<br />

.5A Max, 200V DC, 10 Watt max<br />

1 NC extra late break 52BAU<br />

These can also be used with the 1 5/8” push-pull devices.<br />

For push-pull units starting with part numbers 52PA, 52PE or 52PX, replacement<br />

locknuts can be ordered using 52AANL (Chrome) and 52AXNL (BlackMax).<br />

Hermetically Sealed<br />

Positive opening according to IEC 60947-5-1, Appendix K.<br />

Product Category: PILO<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-323


Pushbutton Units and Indicator Lights<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Accessories and spare parts<br />

Selection and ordering data<br />

Version Suitable for Lamp<br />

voltage<br />

Color<br />

Order no.<br />

Pilot Devices<br />

Lamps with screw connection, miniature bayonet (BA 9s style)<br />

Incandescent lamps,<br />

Flashing, type 267 lamp (replaces 755 lamp) 51, 52 6 V 52AABNF<br />

6V type 755 lamp (Rated 150 mA) 51, 52 6 V 52AABN<br />

12V type 756 (Rated 80 mA) 51, 52 12 V 52AACN<br />

24V type 757 (Rated 80 mA) 51, 52 24 V 52AADN<br />

48V, 2W 52 48 V 3SB1902-1AP<br />

60V, 2W 52 60 V 3SR9424<br />

120V, 2.5W, type #120MB (Rated 250 mA) 52 120 V 52AAENC1<br />

Neon (uses resistors) type B2A (NE-51H) 52 120 V 52AAPN<br />

Candelabra,120V, 3W, Full voltage type 3S6/5 52 older revision styles 120 V 52AAENC<br />

LED bulbs <br />

LED, BA9s type Class 52 6 V AC/DC 52AEBm<br />

24 V AC/DC 52AEDm<br />

120 V AC/DC 52AEEm<br />

Super-Bright LED Class 52 6 V AC/DC 52AEBm7<br />

24 V AC/DC 52AEDm7<br />

120 V AC/DC 52AEEm7<br />

120 V DC 52AEVm7<br />

LED lighting module with integrated LED.<br />

Single LED (Rated 35 mA Maximum) Class 52 24 V AC/DC 52AAILm<br />

120 V AC 52AAIMm<br />

240 V AC 52AAINm<br />

Full voltage lighting module accessory with BA9s type lamp <br />

LED Class 52 6 V AC/DC 52AAFBmB<br />

24 V AC/DC 52AAFDmB<br />

120 V AC/DC 52AAFEmB<br />

Super-Bright LED Class 52 6 V AC/DC 52AAFBmY<br />

24 V AC/DC 52AAFDmY<br />

120 V AC/DC 52AAFEmY<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Incandescent bulb Class 52 6 V AC/DC 52AAFB<br />

24 V AC/DC 52AAFD<br />

120 V AC/DC 52AAFE<br />

Transformer lighting module accessory with BA9s type lamp <br />

LED Class 52 120 V AC 52AATGmB<br />

240 V AC 52AATHmB<br />

480 V AC 52AATJmB<br />

600 V AC 52AATKmB<br />

Super-Bright LED Class 52 120 V AC 52AATGmY<br />

240 V AC 52AATHmY<br />

480 V AC 52AATJmY<br />

600 V AC 52AATKmY<br />

Incandescent bulb Class 52 120 V AC 52AATGN<br />

240 V AC 52AATHN<br />

480 V AC 52AATJN<br />

600 V AC 52AATKN<br />

Color options:<br />

red 2<br />

green 3<br />

yellow/amber 4<br />

blue 5<br />

white/clear B<br />

Standard LED lamps are recommended for indoor applications, Super-Bright<br />

LED Lamps are recommended for outdoor applications.<br />

6V, 24V (Super Bright only) and 120V are currently AC only.<br />

Replaced by AC/DC rated versions end of 2014.<br />

17-324<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: PILO


Pushbutton Units and Indicator Lights<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Dimensional drawings<br />

Non-Illuminated Push-Pull<br />

Metal Mushroom Head<br />

Non-Illuminated Push-Pull<br />

Small Plastic Mushroom Head<br />

Non-Illuminated Push-Pull<br />

Large Plastic Mushroom Head<br />

Pilot Devices<br />

Illuminated Push-Pull<br />

Metal Mushroom Head<br />

Fully Illuminated Push-Pull<br />

Small Plastic Mushroom Head<br />

Illuminated Push-Pull<br />

Large Plastic Mushroom Head<br />

Non-Illuminated Twist Release<br />

Plastic Mushroom Head<br />

Illuminated Twist Release<br />

Plastic Mushroom Head<br />

Illuminated Pushbutton Flush Lens<br />

Illuminated Pushbutton Extended Lens<br />

Illuminated Push to Test<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-325


Pushbutton Units and Indicator Lights<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Dimensional drawings<br />

Selector Switch<br />

Non-Illuminated<br />

Selector Switch<br />

Illuminated<br />

Indicator Light<br />

Plastic Lens<br />

17<br />

Pilot Devices<br />

Momentary Pushbutton<br />

Non-Illuminated Flush Cap<br />

Momentary Pushbutton<br />

Non-Illuminated Raised Cap<br />

Indicator Light<br />

Glass Lens<br />

CONTROL<br />

PRODUCTS<br />

Momentary Pushbutton<br />

Metal Mushroom Head<br />

Momentary Pushbutton<br />

Small Plastic Mushroom Head<br />

Momentary Pushbutton<br />

Large Plastic Mushroom Head<br />

17-326<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Pushbutton Units and Indicator Lights<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Dimensional drawings<br />

Illuminated Momentary Pushbutton<br />

Metal Mushroom Head<br />

Illuminated Momentary Pushbutton<br />

Small Plastic Mushroom Head<br />

Illuminated Momentary Pushbutton<br />

Large Plastic Mushroom Head<br />

Pilot Devices<br />

Selector Switch<br />

Keyed<br />

Wobble Switch<br />

Potentiometer Switch<br />

Toggle Switch<br />

Selector Pushbutton Switch<br />

Flush Cap<br />

Selector Pushbutton Switch<br />

Raised Cap<br />

17 CONTROL<br />

PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-327


Pushbutton Units and Indicator Lights<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Dimensional drawings<br />

Momentary Pushbutton Guard<br />

Illuminated Push to Test Guard<br />

Mushroom Head Guard<br />

Contact Block<br />

CONTROL<br />

PRODUCTS<br />

17<br />

Pilot Devices<br />

Large Metal Legend Plate<br />

Automotive Metal Legend Plate<br />

Large Plastic Legend Plate<br />

17-328<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Pushbutton Units and Indicator Lights<br />

30mm Water, Oil Tight & Corrosion Resistant – Class 52<br />

Revised on 01/31/20<br />

Emergency Power Off Pushbutton (EPO) Stations<br />

Break Glass and Emergency Power Off Pushbutton (EPO) Stations<br />

Selection and ordering data<br />

Description<br />

Degree of<br />

protection<br />

Conduit Entry<br />

3/4" NPT<br />

No. of<br />

command<br />

points<br />

Contact a Legend Plate Order no.<br />

Class 52 Oiltight Pushbutton Stations c<br />

Break Glass<br />

Pushbutton Station<br />

"EMERGENCY SHUT-OFF"<br />

52G112FB<br />

"EMERGENCY OFF"<br />

52G113FB<br />

Side<br />

"EMERGENCY POWER OFF"<br />

52G114FB<br />

"EMERGENCY GENERATOR STOP" 52G115FB<br />

NEMA 4X<br />

1 1NO-1NC<br />

"EMERGENCY POWER OFF"<br />

52G114FR<br />

"EMERGENCY SHUT-OFF" 52G112FR<br />

Rear b "EMERGENCY OFF"<br />

52G113FR<br />

"EMERGENCY GENERATOR STOP" 52G115FR<br />

Rear b "EMERGENCY POWER OFF"<br />

52G114FD<br />

"EMERGENCY SHUT-OFF" 52G112FD<br />

Side and<br />

"EMERGENCY OFF"<br />

52G113FD<br />

"EMERGENCY GENERATOR STOP" 52G115FD<br />

"EMERGENCY SHUT-OFF"<br />

52G112S<br />

"EMERGENCY OFF"<br />

52G113S<br />

NEMA 12/13 N/A 1 1NO-1NC<br />

"EMERGENCY POWER OFF"<br />

52G114S<br />

Pilot Devices<br />

"EMERGENCY GENERATOR STOP"<br />

52G115S<br />

Emergency Power Off<br />

EPO Pushbutton Station<br />

NEMA 4X Side 1 1NO-1NC "EMERGENCY POWER OFF" 52C114EB<br />

NEMA 12/13 N/A 1 1NO-1NC "EMERGENCY POWER OFF" 52C114A<br />

17 CONTROL<br />

PRODUCTS<br />

Accessories<br />

Break Glass Pushbutton with 1NO-1NC, 4 Extra Glass Lens Inserts<br />

Break Glass Pushbutton with 1NO-1NC, 4 Extra Glass Lens Inserts, Mallet, Chain, Clip, Mounting Screw d<br />

Replacement Glass Lens Insert Kit (5 piece pack)<br />

52PM8AGA<br />

52PM8AGAH<br />

52RC1AG<br />

Break Glass Legend Plates e "EMERGENCY POWER OFF"<br />

52NL114R<br />

"EMERGENCY SHUT-OFF" 52NL112R<br />

"EMERGENCY OFF"<br />

52NL113R<br />

"EMERGENCY GENERATOR STOP"<br />

52NL115R<br />

EPO Legend Platee "EMERGENCY POWER OFF" 52NF214R<br />

Enclosure, NEMA 4X Aluminum with ANSI 61 Gray finish comes with one 3/4" - 14 NPT conduit entry in side<br />

of enclosure, and one Empty Command Point for fitting 30mm Round Devices.<br />

P30EMS01EB<br />

a Pushbutton Station comes with 1) 52BJK, 1NO-1NC contact rated NEMA<br />

A600/P600. One additional Class 52 contact block may be field installed if<br />

required.<br />

b Versions with Conduit Entry from the Rear available February 2020.<br />

c All Glass Break Pushbutton Stations come with 4 Extra Glass Lens Inserts.<br />

d Sealant is not supplied with 52PM8AGAH kits. Note: Teflon Tape or Pipe Dope<br />

is required on the Mallet Mounting Clip Screw when field installed in a NEMA 4X<br />

Enclosure.<br />

e For a more comprehensive list of our most common legend plates, see page<br />

10/238 of the Siemens IC Catalog.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-329


Pushbutton Units and Indicator Lights<br />

30mm Water, Oil Tight & Corrosion Resistant - Class 52<br />

Class 52 oiltight pushbutton stations<br />

Selection and ordering data<br />

Pilot Devices<br />

17<br />

CONTROL<br />

PRODUCTS<br />

1 unit control<br />

station<br />

2 unit control<br />

station<br />

Actuator identification<br />

C = top device in station<br />

B = middle device in station<br />

A = bottom device in station<br />

Degree of protection Contact / voltage No. of Order no.<br />

command<br />

points<br />

A = Momentary flush pushbutton black, label “START” NEMA 12 1NO - 1NC 1 52C101A<br />

A = Momentary raised pushbutton red, label “STOP” NEMA 12 1NO - 1NC 1 52C103A<br />

A = Momentary mushroom head red, label “STOP” NEMA 12 1NO - 1NC 1 52C104A<br />

A = Maintained metal mushroom head red, label<br />

NEMA 12 1NO - 1NC 1 52C117A<br />

“EMERGENCY STOP”<br />

A = 2 position selector switch “OFF-ON” NEMA 12 1NO - 1NC 1 52C159A<br />

A = 3 position selector switch “HAND-OFF-AUTO” NEMA 12 1NO - 1NC 1 52C156A<br />

A = Indicator light, red NEMA 12 120V Transformer 1 52C131A<br />

type<br />

A = Indicator light, green NEMA 12 120V Transformer 1 52C135A<br />

type<br />

A = Momentary flush pushbutton black, label “START” NEMA 4X Stainless Steel 1NO - 1NC 1 52C101S<br />

A = Momentary raised pushbutton red, label “STOP” NEMA 4X Stainless Steel 1NO - 1NC 1 52C103S<br />

A = Momentary mushroom head red, label “STOP” NEMA 4X Stainless Steel 1NO - 1NC 1 52C104S<br />

A = Maintained plastic mushroom head red, label<br />

NEMA 4X Stainless Steel 1NO - 1NC 1 52C116S<br />

“EMERGENCY STOP”<br />

A = 2 position selector switch “OFF-ON” NEMA 4X Stainless Steel 1NO - 1NC 1 52C159S<br />

A = 3 position selector switch “HAND-OFF-AUTO” NEMA 4X Stainless Steel 1NO - 1NC 1 52C156S<br />

A = Momentary flush pushbutton black, label “START” NEMA 4X Fiberglass 1NO - 1NC 1 52C101X<br />

A = Momentary raised pushbutton red, label “STOP” NEMA 4X Fiberglass 1NO - 1NC 1 52C103X<br />

A = Momentary mushroom head red, label “STOP” NEMA 4X Fiberglass 1NO - 1NC 1 52C104X<br />

A = Maintained plastic mushroom head red, label<br />

NEMA 4X Fiberglass 1NO - 1NC 1 52C116X<br />

“EMERGENCY STOP”<br />

A = 2 position selector switch “OFF-ON” NEMA 4X Fiberglass 1NO - 1NC 1 52C159X<br />

A = 3 position selector switch “HAND-OFF-AUTO” NEMA 4X Fiberglass 1NO - 1NC 1 52C156X<br />

B = Momentary flush pushbutton black, label “START”<br />

A = Momentary raised pushbutton red, label “STOP”<br />

NEMA 12<br />

1NO, 1NC<br />

1NO, 1NC<br />

2 52C201A<br />

B = Momentary flush pushbutton black, label “START”<br />

A = Momentary Mushroom head pushbutton red,<br />

label “STOP”<br />

B = Momentary flush pushbutton, label “FORWARD”<br />

A = Momentary flush pushbutton, label “REVERSE”<br />

B = Momentary flush pushbutton, label “UP”<br />

A = Momentary flush pushbutton, label “DOWN”<br />

B = Indicator light, red, label “RUN”<br />

A = Maintained selector switch, label<br />

“HAND-OFF-AUTO”<br />

B = Indicator light, red<br />

A = Indicator light, green<br />

B = Momentary flush pushbutton black, label “START”<br />

A = Momentary raised pushbutton red, label “STOP”<br />

B = Momentary flush pushbutton black, label “START”<br />

A = Momentary Mushroom head pushbutton red, label<br />

“STOP”<br />

B = Momentary flush pushbutton, label “UP”<br />

A = Momentary flush pushbutton, label “DOWN”<br />

B = Indicator light, red, label “RUN”<br />

A = Maintained selector switch, label “HAND-OFF-AUTO”<br />

B = Momentary flush pushbutton black, label “START”<br />

A = Momentary raised pushbutton red, label “STOP”<br />

B = Momentary flush pushbutton black, label “START”<br />

A = Momentary Mushroom head pushbutton red, label<br />

“STOP”<br />

B = Momentary flush pushbutton, label “UP”<br />

A = Momentary flush pushbutton, label “DOWN”<br />

B = Indicator light, red, label “RUN”<br />

A = Maintained selector switch, label “HAND-OFF-AUTO”<br />

NEMA 12<br />

NEMA 12<br />

NEMA 12<br />

NEMA 12<br />

NEMA 12<br />

NEMA 4X Stainless Steel<br />

NEMA 4X Stainless Steel<br />

NEMA 4X Stainless Steel<br />

NEMA 4X Stainless Steel<br />

NEMA 4X Fiberglass<br />

NEMA 4X Fiberglass<br />

NEMA 4X Fiberglass<br />

NEMA 4X Fiberglass<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

120V Transformer<br />

type<br />

120V Transformer<br />

type<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

120V Transformer<br />

type<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

120V Transformer<br />

type<br />

1NO, 1NC<br />

2 52C202A<br />

2 52C204A<br />

2 52C223A<br />

2 52C224A<br />

2 52C230A<br />

2 52C201S<br />

2 52C202S<br />

2 52C223S<br />

2 52C224S<br />

2 52C201X<br />

2 52C202X<br />

2 52C223X<br />

2 52C224X<br />

Pack<br />

Unit<br />

NEMA 4X Stainless Steel Enclosure is 304 SS.<br />

17-330<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: PILO


Pushbutton Units and Indicator Lights<br />

30mm Water, Oil Tight & Corrosion Resistant - Class 52<br />

Class 52 oiltight pushbutton stations<br />

Selection and ordering data<br />

Actuator identification Degree of protection Contact /<br />

voltage<br />

No. of Order no.<br />

command<br />

points<br />

Pack<br />

Unit<br />

3 unit control<br />

station<br />

C = Indicator light, red<br />

B = Momentary flush pushbutton black, label “START”<br />

A = Momentary raised pushbutton red, label “STOP”<br />

C = Momentary flush pushbutton black, label “FORWARD”<br />

B = Momentary flush pushbutton black, label “REVERSE”<br />

A = Momentary raised pushbutton red, label “STOP”<br />

C = Momentary flush pushbutton black, label “UP”<br />

B = Momentary flush pushbutton black, label “DOWN”<br />

A = Momentary raised pushbutton red, label “STOP”<br />

C = Momentary flush pushbutton black, label “OPEN”<br />

B = Momentary flush pushbutton black, label “CLOSE”<br />

A = Momentary raised pushbutton red, label “STOP”<br />

C = Momentary flush pushbutton black, label “HI”<br />

B = Momentary flush pushbutton, black label “LOW”<br />

A = Momentary raised pushbutton red, label “STOP”<br />

C = Indicator light, red<br />

B = Momentary flush pushbutton black, label “START”<br />

A = Momentary raised pushbutton red, label “STOP”<br />

C = Momentary flush pushbutton black, label “FORWARD”<br />

B = Momentary flush pushbutton black, label “REVERSE”<br />

A = Momentary raised pushbutton red, label “STOP”<br />

C = Momentary flush pushbutton black, label “UP”<br />

B = Momentary flush pushbutton black, label “DOWN”<br />

A = Momentary raised pushbutton red, label “STOP”<br />

C = Momentary flush pushbutton black, label “OPEN”<br />

B = Momentary flush pushbutton black, label “CLOSE”<br />

A = Momentary raised pushbutton red, label “STOP”<br />

C = Momentary flush pushbutton black, label “HI”<br />

B = Momentary flush pushbutton, black label “LOW”<br />

A = Momentary raised pushbutton red, label “STOP”<br />

C = Indicator light, red<br />

B = Momentary flush pushbutton black, label “START”<br />

A = Momentary raised pushbutton red, label “STOP”<br />

C = Momentary flush pushbutton black, label “FORWARD”<br />

B = Momentary flush pushbutton black, label “REVERSE”<br />

A = Momentary raised pushbutton red, label “STOP”<br />

C = Momentary flush pushbutton black, label “UP”<br />

B = Momentary flush pushbutton black, label “DOWN”<br />

A = Momentary raised pushbutton red, label “STOP”<br />

C = Momentary flush pushbutton black, label “OPEN”<br />

B = Momentary flush pushbutton black, label “CLOSE”<br />

A = Momentary raised pushbutton red, label “STOP”<br />

C = Momentary flush pushbutton black, label “HI”<br />

B = Momentary flush pushbutton, black label “LOW”<br />

A = Momentary raised pushbutton red, label “STOP”<br />

NEMA 12<br />

NEMA 12<br />

NEMA 12<br />

NEMA 12<br />

NEMA 12<br />

NEMA 4X Stainless Steel<br />

NEMA 4X Stainless Steel<br />

NEMA 4X Stainless Steel<br />

NEMA 4X Stainless Steel<br />

NEMA 4X Stainless Steel<br />

NEMA 4X Fiberglass<br />

NEMA 4X Fiberglass<br />

NEMA 4X Fiberglass<br />

NEMA 4X Fiberglass<br />

NEMA 4X Fiberglass<br />

120V<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

120V<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

120V<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

1NO, 1NC<br />

3 52C307A<br />

3 52C301A<br />

3 52C332A<br />

3 52C333A<br />

3 52C334A<br />

3 52C307S<br />

3 52C301S<br />

3 52C332S<br />

3 52C333S<br />

3 52C334S<br />

3 52C307X<br />

3 52C301X<br />

3 52C332X<br />

3 52C333X<br />

3 52C334X<br />

Pilot Devices<br />

17 CONTROL<br />

PRODUCTS<br />

NEMA 4X Stainless Steel Enclosure is 304 SS.<br />

Product Category: PILO<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-331


Pushbutton Units and Indicator Lights<br />

30mm Water, Oil Tight & Corrosion Resistant - Class 52<br />

Empty enclosures<br />

Selection and ordering data<br />

Pilot Devices<br />

Version<br />

Number of<br />

command<br />

points<br />

Degree of<br />

protection<br />

Order No. <br />

Standard enclosures come with 2 1/4” leg 1 NEMA Type 12/13 P30EMS01<br />

center for legend spacing. Automotive 1 NEMA Type 12/13 extra deep P30EMS01D<br />

end plates require 2 1/2 “ spacing. For 1 NEMA Type 4/4X stainless steel P30EMS014<br />

more than 2 contact blocks on the right or 1 NEMA Type 4/4X Fiberglass P30EMS01X<br />

left, use extra deep enclosure. 2 NEMA Type 12/13 P30EMS02<br />

2 NEMA Type 12/13 extra deep P30EMS02D<br />

Mounting hole arrangement 2 NEMA Type 4/4X stainless steel P30EMS024<br />

2 NEMA Type 4/4X Fiberglass P30EMS02X<br />

1 thu 4 are in one row 3 NEMA Type 12/13 P30EMS03<br />

6 holes are 3 down and 2 across 3 NEMA Type 12/13 extra deep P30EMS03D<br />

9 holes are 3 down and 3 across 3 NEMA Type 4/4X stainless steel P30EMS034<br />

12 holes are 4 down and 3 across 3 NEMA Type 4/4X Fiberglass P30EMS03X<br />

16 holes are 4 down and 4 across 4 NEMA Type 12/13 P30EMS04<br />

4 NEMA Type 12/13 extra deep P30EMS04D<br />

4 NEMA Type 4/4X stainless steel P30EMS044<br />

4 NEMA Type 4/4X Fiberglass P30EMS04X<br />

6 NEMA Type 12/13 P30EMS06<br />

6 NEMA Type 12/13 extra deep P30EMS06D<br />

6 NEMA Type 4/4X stainless steel P30EMS064<br />

9 NEMA Type 12/13 P30EMS09<br />

9 NEMA Type 12/13 extra deep P30EMS09D<br />

9 NEMA Type 4/4X stainless steel P30EMS094<br />

12 NEMA Type 12/13 P30EMS12<br />

12 NEMA Type 12/13 extra deep P30EMS12D<br />

12 NEMA Type 4/4X stainless steel P30EMS124<br />

16 NEMA Type 12/13 P30EMS16<br />

16 NEMA Type 12/13 extra deep P30EMS16D<br />

16 NEMA Type 4/4X stainless steel P30EMS164<br />

Pack<br />

Unit<br />

Order Form<br />

17<br />

CONTROL<br />

PRODUCTS<br />

1<br />

2<br />

3<br />

4<br />

A<br />

Location<br />

B C D<br />

Enclosure Hole Arrangement<br />

Ordering Information<br />

To order non-standard control stations select catalog numbers<br />

from the previous pages, determine the required position in the<br />

enclosure and fill in the table below. If a special legend plate is<br />

required, specify description in the table. The combined list<br />

prices of the components is the list price of the station.<br />

• Select enclosure<br />

• Vertical or Horizontal. Outline Diagram at left starting at the<br />

top left-hand corner. Example: 3 unit vertical outline location<br />

No. 1A, 2A and 3A. 3 unit horizontal outline location No. 1A,<br />

1B, and 1C<br />

• List location No. and applicable catalog numbers in the table<br />

below. Use complete catalog numbers where possible<br />

Operator<br />

PB-SEL.-PL<br />

Accessories<br />

Key Lock, Boot, Etc,<br />

Legend Plate<br />

Legend or Blank<br />

Order No./Item No.<br />

Customer<br />

Enclosure Catalog No.<br />

Special Marking<br />

NEMA 4X Stainless Steel Enclosure is 304 SS.<br />

17-332<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: PILO


Pushbutton Units and Indicator Lights<br />

30 mm Heavy Duty, Watertight/Oiltight, Class 52 Legend plates for Class 51 and 52<br />

Design<br />

The 30 mm legend plates are approved for the use with both Class 51 and Class 52 devices.<br />

Automotive legend plates require 2 1/2” mounting centers. Plastic legend plates will have white letters ingraved.<br />

When ordering custom engraved legend plates, specify the required inscription text.<br />

Selection and ordering data<br />

Inscription<br />

Large<br />

(1 1/4” x 2”)<br />

Order No.<br />

Automotive <br />

(2 7/16” x 2 7/16”)<br />

Order No.<br />

Large Plastic <br />

(2 1/16” x 2”)<br />

Order No.<br />

Automotive<br />

Plastic <br />

(2 7/16” x 2 7/16”)<br />

Order No.<br />

1 1/4<br />

1 5/8<br />

2<br />

2 7/16<br />

2 7/16<br />

“Blank (brushed aluminum)” 52NL02 52NA02 — —<br />

“Blank (red)” 52NL02R 52NA02R 52ND02R 52NE02R<br />

“Blank (Black)” 52NL02B 52NA02B 52ND02B 52NE02B<br />

Inscribed legend plates with large brushed aluminum background<br />

Close 52NL18 52NA18 — —<br />

Down 52NL10 52NA10 — —<br />

Emerg Stop 52NL16 52NA16 — —<br />

Emerg Stop (red) 52NL16R 52NA16R — —<br />

Fast-Slow 52NL33 52NA33 — —<br />

Forward 52NL05 52NA05 — —<br />

For-Off-Rev 52NL38 52NA38 — —<br />

For-Rev 52NL31 52NA31 — —<br />

Hand-Off-Auto 52NL37 52NA37 — —<br />

High 52NL07 52NA07 — —<br />

High-Low 52NL30 52NA30 — —<br />

High-Off-Low 52NL44 52NA44 — —<br />

In 52NL21 52NA21 — —<br />

Jog 52NL13 52NA13 — —<br />

Jog-Forward 52NL24 52NA24 — —<br />

Jog-Reverse 52NL25 52NA25 — —<br />

Low 52NL08 52NA08 — —<br />

Lower 52NL20 52NA20 — —<br />

Man-Auto 52NL35 52NA35 — —<br />

Off 52NL12 52NA12 — —<br />

Off-On 52NL26 52NA26 — —<br />

On 52NL11 52NA11 — —<br />

On-Off-Auto 52NL40 52NA40 — —<br />

Open 52NL17 52NA17 — —<br />

Open-Close 52NL34 52NA34 — —<br />

Open-Off-Close 52NL41 52NA41 — —<br />

Out 52NL22 52NA22 — —<br />

Pull to Start Push to Stop 52NL47 52NA47 — —<br />

Raise 52NL19 52NA19 — —<br />

Raise-Lower 52NL36 52NA36 — —<br />

Reset 52NL14 52NA14 — —<br />

Reverse 52NL06 52NA06 — —<br />

Run 52NL23 52NA23 — —<br />

Run-Jog 52NL29 52NA29 — —<br />

Safe-Run 52NL27 52NA27 — —<br />

Slow-Off-Fast 52NL39 52NA39 — —<br />

Start 52NL03 52NA03 — —<br />

Start-Jog 52NL28 52NA28 — —<br />

Start-Stop 52NL32 52NA32 — —<br />

Stop 52NL04 52NA04 — —<br />

Stop (red) 52NL04R 52NA04R — —<br />

Up 52NL09 52NA09 — —<br />

Up-Down 52NL49 52NA49 — —<br />

Up-Off-Down 52NL42 52NA42 — —<br />

Pilot Devices<br />

17 CONTROL<br />

PRODUCTS<br />

Inscription plates with custom engraving<br />

“Custom engraved<br />

52NL02E 52NA02E — —<br />

(brushed aluminum)”<br />

“Custom engraved (red)” 52NL02RE 52NA02RE 52ND02RE 52NE02RE<br />

“Custom engraved (Black)” 52NL02BE 52NA02BE 52ND02BE 52NE02BE<br />

Max. number of rows 2 2 2 2<br />

Letter height 5/32” 1/4” 5/32” 1/4”<br />

Characters per row 14 16 14 16<br />

Automotive requires 2 1/2” mounting centers<br />

White letters on plastic nameplate.<br />

Product Category: PILO<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-333


Pushbutton Units and Indicator Lights<br />

30mm Heavy Duty, Watertight/Oiltight, Class 52<br />

Dimensional drawings<br />

Hole Arrangement<br />

Pilot Devices<br />

Standard 4-Way<br />

Type 4X Non-Metallic<br />

.190<br />

(5)<br />

1.210<br />

(31)<br />

.672<br />

(17)<br />

Type 12/13 and 4X Stainless Steel<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Enclosure Size Mounting Overall<br />

Units A B C G H L W J T X Y<br />

1 3.50 (89) 3.25 (83) 2.75 (70) 4.00 (102) 2.38 (60) 4.50 (114) 3.47 (88) 2.31 (59) 3.00 (76) 1.73 (44) 1.86 (47)<br />

2 5.75 (146) 3.25 (83) 2.75 (70) 6.25 (159) 2.38 (60) 6.75 (171) 3.47 (88) 2.31 (59) 3.00 (76) 1.73 (44) 1.86 (47)<br />

3 8.00 (203) 3.25 (83) 2.75 (70) 8.50 (216) 2.38 (60) 9.00 (229) 3.47 (88) 2.31 (59) 3.00 (76) 1.73 (44) 1.86 (47)<br />

4 10.25 (260) 3.25 (83) 2.75 (70) 10.75 (273) 2.38 (60) 11.25 (286) 3.47 (88) 2.31 (59) 3.00 (76) 1.73 (44) 1.86 (47)<br />

6 9.50 (241) 6.25 (159) 3.00 (76) 10.00 (254) 5.38 (137) 10.50 (267) 6.47 (164) 2.56 (65) 6.00 (152) 2.11 (54) 2.61 (66)<br />

9 9.50 (241) 8.50 (216) 3.00 (76) 10.00 (254) 7.62 (194) 10.50 (267) 8.72 (221) 2.56 (65) 8.25 (210) 2.11 (54) 2.61 (66)<br />

12 11.75 (298) 8.50 (216) 3.00 (76) 12.25 (311) 7.62 (194) 12.75 (324) 8.72 (221) 2.56 (65) 8.25 (210) 2.11 (54) 2.61 (66)<br />

16 2 ) 11.75 (298) 10.75 (273) 3.00 (76) 12.25 (311) 9.88 (251) 12.75 (324) 10.97 (279) 2.56 (65) 2 ) 10.50 (267) 2.11 (54) 2.61 (66)<br />

Type 12/13 Extra Deep Enclosures<br />

Enclosure Size Mounting Overall<br />

Units A B C G H L W J T X Y<br />

1 4.00 4.00 4.75 4.50 3.12 5.00 4.22 4.31 3.75 2.11 2.11<br />

2 6.00 4.00 4.75 6.50 3.12 7.00 4.22 4.31 3.75 2.11 1.98<br />

3 8.00 4.00 4.75 8.50 3.12 4.31 3.75 2.11 1.86<br />

4 10.00 4.00 4.75 10.50 3.12 11.00 4.22 4.31 3.75 2.11 1.73<br />

6 9.50 6.25 4.75 10.00 5.38 4.31 6.00<br />

9 9.50 8.50 4.75 10.00 7.62 10.50 8.25 2.11 2.61<br />

12 4.75 12.25 7.62 4.31 8.25<br />

16 2 ) 1 4.75 12.25 9.88 12.75 10.97 4.31 10.50 2.11 2.61<br />

Type 4X Non-Metallic<br />

Enclosure Size Mounting Overall<br />

Units A B C G H L W<br />

1 6.00 3.19 3.63 4.88 2.94 6.63 3.81<br />

2 6.00 3.19 3.63 4.88 2.94 6.63 3.81<br />

3 8.26 3.19 3.63 7.13 2.94 8.88 3.81<br />

4 10.51 3.19 3.63 9.37 2.94<br />

All dimensions shown in inches and (millimeters). For<br />

reference purposes only. Not to be used for design or<br />

construction purposes.<br />

1) Grounding stud in body of enclosure.<br />

2) For stainless steel add 1.75 (45) to depth.<br />

17-334<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category: PILO


Pushbutton Units and Indicator Lights<br />

30 mm Pilot Devices Technical Specifications<br />

Standards UL Listed File # E22655 CSA Certified File # LR6535<br />

Utilization Category NEMA A600/P600<br />

Degree of Protection 52B, 52P-, 52S-, 52M- Operators NEMA: 1, 3, 3R, 4, 4X, 12 and 13<br />

IEC 529; IP10, IP11, IP14, IP52, IP54, IP56 and IP66<br />

Rated Operational Current<br />

Contact Blocks<br />

NEMA A600 – 10 Continuous Amps<br />

Voltage AC Make Amps Break Amps<br />

120V 60 6<br />

240V 30 3<br />

480V 15 1.5<br />

600V 12 1.2<br />

Total VA 7200 720<br />

52BAK, -BAJ , -BAH, -BAU, -BJK <br />

52BAR<br />

NEMA P600 – Rating Codes for DC Control<br />

Circuit Application<br />

Thermal Continuous Test Current Amps 5.0<br />

Maximum Make or Break; Current / Amps<br />

125V 1.10<br />

250V 0.55<br />

301-600V 0.20<br />

Maximum Make or Break<br />

Volt amperes at 300V or Less 138<br />

600VAC Maximum, Heavy Duty<br />

200VAC .25 Amp, 10 Watt Maximum<br />

200VDC .50 Amp, 10 Watt Maximum<br />

Positively driven contacts. Contact blocks are suitable for applications down to 5V/1MA low voltage applications as found in<br />

PLCs. 52BAR are Class 1; Division 2 Compliant<br />

Pilot Light<br />

Push-to-Test<br />

Illuminated<br />

Push-Pull<br />

Twist-to-<br />

Release<br />

Illuminated<br />

Selector<br />

Switch<br />

Dielectric Strength<br />

Full Voltage<br />

LED Module<br />

Transformer Type<br />

Full Voltage<br />

LED Module<br />

Transformer Type<br />

Full Voltage<br />

LED Module<br />

Transformer<br />

Full Voltage<br />

LED Module<br />

Transformer<br />

Full Voltage<br />

Transformer<br />

Mechanical Design Life Cycles<br />

Vibration<br />

Pushbuttons<br />

Push-Pull<br />

Twist-to-Release<br />

Selector<br />

Switches<br />

Contact Operation<br />

Wire Gauge<br />

Terminal Screw Torque<br />

Locknut Torque<br />

Temperature<br />

Range<br />

52PL4/52PL5<br />

or<br />

52BL4/52BL5<br />

52PT6<br />

or<br />

52BT6<br />

52PP2(3,7)<br />

or<br />

52BP2(3,7)<br />

52BR8<br />

or<br />

52PR8<br />

52SA7(A,B,C)<br />

or<br />

52SX7(A,B,C)<br />

-B (6-8V), -C (12V), -D (24V), -E (120V), -F (240V)<br />

-L (24V), -M (120V) -N (240V)<br />

-G (120V), -H (240V), -J (480V), -K (600V)<br />

-B (6-8V), -C (12V), -D (24V), -E (120V), -F (240V)<br />

-L (24V), -M (120V), -N (240V)<br />

-G (120V), -H (240V), -J (480V), -K (600V)<br />

-B (6-8V), -C (12V), -D (24V), -E (120V), -F (240V)<br />

-L (24V), -M (120V), - N (240V)<br />

-G (120V), -H (240V), -J (480V), -K (600V)<br />

-B (6-8V), -C (12V), -D (24V), -E (120V), -F (240V)<br />

-L (24V), -M (120V), - N (240V)<br />

-G (120V), -H (240V), -J (480V), -K (600V)<br />

-B (6-8V), -C (12V), -D (24V), -E (120V), -F (240V)<br />

-G (120V), -H (240V), -J (480V), -K (600V)<br />

2200V for one minute<br />

240V AC/DC Max.<br />

240V AC Max.<br />

600V AC Max., 50/60 Hz<br />

240V AC/DC Max.<br />

240V AC Max.<br />

600VAC Max., 50/60 Hz<br />

240V AC/DC Max.<br />

240V AC Max.<br />

600VAC Max., 50/60 Hz<br />

240V AC/DC Max.<br />

240V AC Max.<br />

600VAC Max., 50/60 Hz<br />

240V AC/DC Max.<br />

600V AC Max., 50/60 Hz<br />

Frequency 5 - 60Hz.; Disp. .030 inches, sweep 5 minutes for a duration of 30 minutes on<br />

each axis. Not to exceed 5.5 G’s for maximum of 1 minute.<br />

Momentary, Non-illuminated<br />

5,000,000 Operating Cycles<br />

Momentary, Illuminated<br />

300,000 Operating Cycles<br />

Maintained<br />

Momentary<br />

Non-illuminated<br />

Illuminated, Key-operated<br />

Standard Contact Black<br />

Logic Reed<br />

#18-12 AWG<br />

2-10 lb-in / 20 lb-in max; 8 lb-in recommended<br />

15 ft. lbs. max<br />

Operating<br />

Storage<br />

300,000 Operating Cycles<br />

2,000,000 Operating Cycles<br />

300,000 Operating Cycles<br />

2,000,000 Operating Cycles<br />

2,000,000 Operating Cycles<br />

31F to +158F (-35C to +70C)<br />

40F to +185F (-40C to +85C)<br />

Pilot Devices<br />

17 CONTROL<br />

PRODUCTS<br />

All parts are designed and manufactured of corrosion resistant material or are plated or painted as corrosion protection. All contact block contacts are gold<br />

flashed as a standard offering. Internal return spring mechanisms of operators and contact blocks of stainless steel. RoHS Compliant.<br />

Declaration of Conformity — The products listed below, to which this declaration relates, are in conformity with the following standards, following the<br />

provisions of the Low Voltage Directive (LVD) (73/23/EEC), and the Electromagnetic Compatibility Directive (89/336/EEC.)<br />

Products: Contact Blocks: Cat Nos. 52BAE, 52BAH, 52BAJ, 52BAK, 52BAR, 52BAU and 52BJK, with suffixes. Pilot Lights: Cat Nos 52P, with suffixes.<br />

Operators: Cat Nos 52S or 52P, with suffixes.<br />

Applicable Standards: EN 60947-5-1 Low-Voltage Switchgear and controlgear. Enclosed devices meet the requirements of environmental ratings of IP10,<br />

IP11, IP14, IP52, IP54, and IP56. Open devices, when mounted as instructed, in environmental type IP10, IP11, IP14, IP52, IP54 or IP56 enclosures, maintain<br />

the environmental requirements for those enclosure types. Cat. No. 52BP, 52BR, 52PP, and 52PR, 2 Position, Twist-To-Release and 2 Position, Push<br />

Pull Maintained operators provided with red operating heads and 52BJK contact blocks meet the requirements of EN 60947-5-5 for Electrical Emergency<br />

Stop Device With Mechanical Latching Function (e-stop).<br />

Product Category: PILO<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-335


Push Button Units and Indicator Lights<br />

30.5mm Pilot Device<br />

Class 52 convenience center<br />

Complete convenience center<br />

Catalog number: POP<strong>2017</strong><br />

Complete point-of-purchase convenience center<br />

This starter kit features all of the devices and stand required for you to start<br />

selling Siemens.<br />

Pilot Devices<br />

Includes point of-purchase components:<br />

(8) Pilot light: Red, SB LED, 120V transformer 52PL4G2XYP<br />

(4) Pilot light: Red, SB LED, 24V full voltage 52PL4D2XYP<br />

(4) Pilot light: Red, SB LED, 120V full voltage 52PL4E2XYP<br />

(8) Basic pushbutton: Red extended, 1NC 52PM8B2JP<br />

(4) Basic pushbutton: Green flat, 1NO 52PM8A3KP<br />

(4) Push-Pull E-STOP: Red mushroom head 52PP2W2AP<br />

(4) Twist-to-Release E-STOP: Red Mushroom Head 52PR8W2AP<br />

(4) Selector switch: 3-pos, maintained 52SA2CABA1P<br />

(4) Selector switch: 2-pos, maintained 52SA2AABA1P<br />

(4) Illuminated pushbutton: Red, SB LED, 24V full voltage 52PT6D2AYP<br />

(4) Illuminated pushbutton: Red, SB LED, 120V full voltage 52PT6G2AYP<br />

(4) 30mm pushbutton station: 1 hole P30EMS01P<br />

(2) 30mm pushbutton station: 2 hole P30EMS02P<br />

(2) 30mm pushbutton station: 3 hole P30EMS03P<br />

(1) Point-of-purchase display stand 52STANDPOP<br />

Pilot lights<br />

17<br />

CONTROL<br />

PRODUCTS<br />

Catalog number:<br />

52PL4D2XYP<br />

Pilot light: Red, 24V full voltage<br />

with Super-Bright LED and two extra<br />

lenses in green and amber; and two<br />

legend plates: “On” and “Stop.”<br />

Catalog number:<br />

52PL4E2XYP<br />

Pilot light: Red, 120V full voltage<br />

with Super-Bright LED; two extra lenses<br />

in green and amber; and two legend<br />

plates: “On” and “Stop.”<br />

Catalog number:<br />

52PL4G2XYP<br />

Pilot light: Red, 120V transformer<br />

with Super-Bright LED; two extra lenses<br />

in green and amber; and two legend<br />

plates: “On” and “Stop.”<br />

Includes components:<br />

(1) Red, 24V Full Voltage,<br />

Pilot light, Super-Bright LED 52PL4DXY<br />

(1) Green lens 52RA4S3<br />

(1) Amber lens 52RA4S9<br />

(1) “On” legend 52NL11<br />

(1) “Stop” legend 52NL04<br />

Includes components:<br />

(1) Red, 120V Full Voltage<br />

Pilot Light, Super-Bright LED 52PL4E2XY<br />

(1) Green lens 52RA4S3<br />

(1) Amber lens 52RA4S9<br />

(1) “On” legend 52NL11<br />

(1) “Stop” legend 52NL04<br />

Includes components:<br />

(1) Red, 120V Transformer<br />

Pilot Light, Super-Bright LED 52PL4G2XY<br />

(1) Green lens 52RA4S3<br />

(1) Amber lens 52RA4S9<br />

(1) “On” legend 52NL11<br />

(1) “Stop” legend 52NL04<br />

Enclosures<br />

Catalog number:<br />

P30EMS01P<br />

Catalog number:<br />

P30EMS02P<br />

Catalog number:<br />

P30EMS03P<br />

30mm pushbutton station: 1 hole<br />

NEMA 12/13 (IP52/54) standard enclosure<br />

30mm pushbutton station: 2 hole<br />

NEMA 12/13 (IP52/54) standard enclosure<br />

30mm pushbutton station: 3 hole<br />

NEMA 12/13 (IP52/54) standard enclosure<br />

17-336<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Push Button Units and Indicator Lights<br />

30.5mm Pilot Device<br />

Class 52 convenience center<br />

Pushbuttons<br />

Emergency stop<br />

Catalog number:<br />

52PM8A3KP<br />

Catalog number:<br />

52PM8B2JP<br />

Catalog number:<br />

52PP2W2AP<br />

Basic pushbutton: Green flat<br />

momentary with 1NO. Includes extra<br />

caps in black, red, yellow and blue and<br />

two legend plates: “On” and “Start.”<br />

Basic pushbutton: Red extended<br />

momentary with 1NC. Includes extra caps<br />

in black and green and two legend plates:<br />

“Stop” and “Off.”<br />

Push-pull: Red mushroom head<br />

2-Pos, maintained, 1 3⁄4” mushroom head,<br />

1NO-1NC, includes extra 2 1⁄2” mushroom<br />

head, two “Stop” legends, and a 90mm<br />

ring inscribed with “Emergency Stop.”<br />

Includes components:<br />

(1) Green, momentary<br />

pushbutton with 1NO 52PM8A3K<br />

(1) Black cap 52RC1A1<br />

(1) Red cap 52RC1A2<br />

(1) Yellow cap 52RC1A4<br />

(1) Blue cap 52RC1A5<br />

(1) “On” legend 52NL11<br />

(1) “Start” legend 52NL03<br />

Includes components:<br />

(1) Red, momentary extended<br />

head pushbutton with 1NC 52PM8B2J<br />

(1) Black cap 52RC1B1<br />

(1) Green cap 52RC1B3<br />

(1) “Stop” legend, red 52NL04R<br />

(1) “Off” legend 52NL12<br />

Includes components:<br />

(1) Red, E-STOP with 1 3⁄4”<br />

mushroom head, 2-pos,<br />

mntd, 1NO-1NC 52PP2W2A<br />

(1) 2 1⁄2” mushroom head 52RC3E2<br />

(1) “Stop” legend, red 52NL04R<br />

(1) “Stop” legend 52NL04<br />

(1) E-STOP ring legend 52AAR<br />

Pilot Devices<br />

Pushbuttons<br />

Emergency stop<br />

Catalog number:<br />

52PT6D2AYP<br />

Catalog number:<br />

52PT6G2AYP<br />

Catalog number:<br />

52PR8W2AP<br />

Illuminated pushbutton: Red<br />

24V full voltage, Super-Bright LED,<br />

1NC-1NO includes extra lenses in green<br />

and amber, and two blank legend plates.<br />

Illuminated pushbutton: Red<br />

120V transformer, Super-Bright LED,<br />

1NC-1NO includes extra lenses in green<br />

and amber, and two blank legend plates.<br />

Twist-to-release: Red mushroom head<br />

2-Pos, maintained, 1 3⁄4” mushroom head,<br />

1NO-1NC, two “Stop” legends, and a 90mm<br />

ring inscribed with “Emergency Stop.”<br />

Includes components:<br />

(1) Red, illuminated pushbutton,<br />

24 full voltage, Super-Bright<br />

LED with 1NC-1NO 52PT6D2AY<br />

(1) Green lens 52RA5S3<br />

(1) Amber lens 52RA5S9<br />

(2) Blank legend 52NL02<br />

Includes components:<br />

(1) Red, illuminated Pushbutton,<br />

120V transformer, Super-Bright<br />

LED with 1NC-1NO 52PT6G2AY<br />

(1) Green lens 52RA5S3<br />

(1) Amber lens 52RA5S9<br />

(2) Blank legend 52NL02<br />

Includes components:<br />

(1) Red, E-STOP with 1 3⁄4” mushroom<br />

mushroom head, 2pos, mntd,<br />

1NO-1NC<br />

52PR8W2A<br />

(1) “Stop” legend, red 52NL04R<br />

(1) “Stop” legend 52NL04<br />

(1) E-STOP ring legend 52AAR<br />

17 CONTROL<br />

PRODUCTS<br />

Selector switch<br />

Display stand<br />

Catalog number:<br />

52SA2CABA1P<br />

Catalog Number:<br />

52SA2AABA1P<br />

Catalog number:<br />

52STANDPOP<br />

Selector switch:<br />

3 Position maintained, short lever,<br />

1NO-1NC, with two legend plates:<br />

“Hand-Off-Auto” and “For-Off-Rev.”<br />

Includes components:<br />

(1) 3-Position maintained<br />

short lever selector switch<br />

with 1NO-1NC<br />

52SA2CABA1<br />

(1) “Hand-Off-Auto” legend 52NL37<br />

(1) “For-Off-Rev” legend 52NL38<br />

Selector switch:<br />

2 Position maintained, short lever,<br />

1NO-1NC, with two legend plates:<br />

“Forward-Reversing” and “Off-On.”<br />

Includes components:<br />

1) 2-Position maintained<br />

short lever selector switch<br />

with 1NO-1NC<br />

52SA2AABA1<br />

(1) “Forward-Reversing”<br />

legend<br />

52NL31<br />

(1) “Off-On” legend 52NL26<br />

Point-of-purchase display stand<br />

Two side swivel display stand.<br />

POP Stand<br />

52STANDPOP<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-337


Push Button Units and Indicator Lights<br />

Notes<br />

CONTROL<br />

PRODUCTS<br />

17<br />

Pilot Devices<br />

17-338<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Standby Generators<br />

SPEEDFAX TM<br />

Section<br />

Standby Generator<br />

Discontinuation —<br />

Phase out of all Standby<br />

Generators and Accessories<br />

Please note: Siemens Low Voltage & Products has exited the standby<br />

generator business.<br />

In 2019, we began the process with the phase out of standby generators.<br />

The following is what to expect during this phase out process:<br />

1. No new system orders will be taken after December 31, 2018.<br />

2. Requirements for replacement parts will continue to be supported for product<br />

under warranty. The timing of the support is calculated based on existing<br />

warranty commitments as well as expected normal product mortality life.<br />

If you have any questions about this announcement or have the need for<br />

replacement parts for an existing system please contact your Siemens sales<br />

representative for more information and assistance.<br />

18 STANDBY<br />

GENERATORS<br />

Scan to connect<br />

online to the<br />

most up-todate<br />

version of<br />

this Section of<br />

SPEEDFAX.<br />

(Section was last modified on 09/09/19)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 18-1


Standby Generators<br />

Notes<br />

STANDBY<br />

GENERATORS<br />

18<br />

18-2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Renewable Energy Products<br />

SPEEDFAX TM<br />

Section<br />

C o n t e n t s<br />

Electric Vehicle Supply Equipment (EVSE)<br />

VersiCharge Features and Benefits 19-2<br />

VersiCharge EVSE Catalog Logic, Accessories and Modules 19-3<br />

VersiCharge Installation Options 19-4<br />

VersiCharge Outdoor Post Options 19-5<br />

VersiCharge Technical Features 19-6<br />

VersiComm Cellular Gateway 19-7<br />

VersiCharge<br />

wall mount<br />

Solar Photovoltaic (PV) Products (discontinued product) 19-8<br />

Siemens Microinverter System<br />

Microinverter Trunk and Drop Cabling<br />

Envoy Microinverter System Components<br />

Microinverter Accessories<br />

VersiComm<br />

Cellular<br />

Gateway<br />

VersiCharge<br />

with outdoor<br />

mounting post<br />

19 RENEWABLE<br />

ENERGY PRODUCTS<br />

Scan to connect<br />

online to the<br />

most up-todate<br />

version of<br />

this Section of<br />

SPEEDFAX.<br />

(Section was last modified on 06/06/19)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 19-1


Renewable Energy Products<br />

Revised on 06/30/19<br />

VersiCharge Features and Benefits<br />

Siemens VersiCharge line offers a<br />

variety of residential and semi-public<br />

electric car charger options.<br />

Ranging from hardwired models, plug in alternatives, and<br />

a Wi-Fi enabled charger. For higher volume areas like<br />

apartments, townhomes, parking lots, applications where a<br />

wall isn’t available, or pedestal mount is preferred, there is<br />

a stationary post to mount the VersiCharge onto.<br />

Load Control<br />

Compatible<br />

n Inputs to remotely<br />

turn unit on or off<br />

n Allows for control by home<br />

automation system or utility<br />

company<br />

19<br />

RENEWABLE<br />

ENERGY PRODUCTS<br />

Easy, 2 Button Controls<br />

n Indicating Halo for easy status check<br />

n Left Button stops and restarts charging<br />

n Right Button sets 2, 4, 6, or 8 hour<br />

Charge Delay<br />

n LED Indicators for each<br />

Cord Management<br />

n Enclosure is<br />

designed for cord<br />

to be looped when<br />

not in use<br />

n Built in J-Plug<br />

Holster stores and<br />

protects plug from<br />

weather, debris,<br />

and damage<br />

n All VersiCharge<br />

units come with<br />

long flexible cord<br />

for easy charging<br />

Adjustable Amperage<br />

n Allows for changing charge rate<br />

to accommodate demand response<br />

signals, for customer preference,<br />

circuit capability and car charging<br />

rate capacity<br />

Hinged Lid for Speed and Ease<br />

n Hinged cover stays in place for<br />

easy maintenance<br />

n No components in cover mean no<br />

risk of damage<br />

n Ample spacing to work inside device<br />

n One hand open / close<br />

n Cover uses only 4 screws compared<br />

to up to 12 for competitors<br />

NEMA 4 Rated Enclosure<br />

n Rated for direct water spray by<br />

sprinklers, hoses, or any weather<br />

n ~50% recycled plastic content<br />

n Glass impregnated plastic for strength<br />

and fire safety<br />

Smart Grid Capabilities<br />

n The VersiCharge SG unit comes with the same standard hardware as<br />

the VC30GRYU but with the added benefit of Wi-Fi and a CTA2045<br />

module to enable communication through the Siemens Cloud.<br />

n Monitor and control charging status, charging schedule, and power level<br />

remotely through the VersiCharge SG SmartPhone App or via provided<br />

web pages<br />

n Built in metering captures real time power usage data for easy to<br />

understand metrics<br />

n The Siemens Billing-Enabled VersiCharge SG allows connection to 3rd<br />

party network provides using Open Charge Point Protocol (OCPP)<br />

19-2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Renewable Energy Products<br />

Revised on 06/30/19<br />

VersiCharge Catalog Logic, Accessories and Modules<br />

Electric Vehicle Supply Equipment<br />

­<br />

Product System<br />

VC = Versicharge<br />

Smart Grid (Optional)<br />

SG = Optional Smart Grid configuration<br />

Output Amperage<br />

30 = 30 A<br />

Color<br />

G = Light Grey<br />

Open Charge<br />

CP = Open Charge Point Protocol (OCPP)<br />

Installation Option<br />

U = Universal (bottom/rear fed, hardwired/permanent)<br />

HW = Hardwired/permanent<br />

Wi-fi Option<br />

W = Included CTA2045 Wi-Fi Module<br />

VC SG 30 G CP U W<br />

VersiCharge electric vehicle chargers<br />

Part number<br />

Model<br />

Output<br />

amperage Color Feeder Location<br />

VC30GRYU Universal VersiCharge 30A Grey Rear/Bottom/Hardwired<br />

VC30GRYHW Hardwired VersiCharge 30A Grey Hardwired<br />

VCSG30GRYUW Wi-Fi VersiCharge 30A Grey Rear/Bottom/Hardwired<br />

VCSG30GCPUW OCPP & Wi-Fi VersiCharge 30A Grey Rear/Bottom/Hardwired<br />

Accessories<br />

Part number Description Color<br />

VCMNTGBRK Spare parts mounting bracket Black<br />

VCPOSTGRY Outdoor mounting post Grey<br />

VCPOSTGRY2 Outdoor dual mounting post Grey<br />

VCCMSSP Outdoor Single Cable management system Grey<br />

VCCMSDP Outdoor Dual Cable management system Grey<br />

19 RENEWABLE<br />

ENERGY PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 19-3


Renewable Energy Products<br />

Revised on 06/30/19<br />

VersiCharge EVSE Installation Options<br />

Flexible<br />

Install<br />

Options<br />

Hardwired from behind<br />

Hardwired via bottom<br />

fed circuit<br />

240 V Plug External 240 V Plug from behind<br />

(Plug is hidden)<br />

Wall Mounted EVSE<br />

Outdoor Mounting Post<br />

tamper resistant hardware kit included<br />

18<br />

12<br />

49<br />

14.5” W x 16.0” H x 6.5” D (front of unit excluding connector) 15”<br />

minimum clearance recommended for connector when inserted.<br />

19<br />

RENEWABLE<br />

ENERGY PRODUCTS<br />

Mounting Bracket<br />

included with every Siemens VersiCharge<br />

2.5” x 16.9”<br />

Install at a<br />

minimum of 18”<br />

off the ground<br />

20 -1/2<br />

13<br />

19-4<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Renewable Energy Products<br />

Revised on 06/30/19<br />

VersiCharge EVSE Outdoor Post Options<br />

Dual Post Mounting<br />

6”<br />

TM<br />

Siemens VersiCharge : Dual Post<br />

7 8 ”<br />

7 8 ”<br />

4”<br />

4”<br />

3 ”<br />

0.312D<br />

1<br />

3 8 ”<br />

2.65”<br />

2.65”<br />

2”<br />

1 8<br />

13 1/4 ”<br />

1.05D<br />

2”<br />

1.05D<br />

4”<br />

4”<br />

Part Number: US2:VCPOSTGRY2<br />

4”<br />

Mounting Holes<br />

2”<br />

C<br />

1 1 2“<br />

2 7 8“<br />

12 5 8“<br />

D<br />

D<br />

48”<br />

16 5 16“<br />

C<br />

C<br />

D<br />

10-32 THREADED<br />

1/4-20 THREADED<br />

Right Left Front Back<br />

TM<br />

Siemens VersiCharge : Cable Management 20ft for Single Post<br />

Single Post: Cable management for 20ft post<br />

Part Number: US2:VCCMSSP<br />

5” 5”<br />

3” 3”<br />

”<br />

4”<br />

7 8<br />

3 ”<br />

1 8<br />

2”<br />

Mounting Holes<br />

2”<br />

3”<br />

4”<br />

2”<br />

79”<br />

4”<br />

2”<br />

2.65”<br />

1.05D<br />

0.312D<br />

1 1 2“<br />

2 7 8“<br />

12 5 8“<br />

C<br />

16 5 16“<br />

10-32 THREADED<br />

C<br />

D<br />

C<br />

13 1/4 ”<br />

D<br />

19 RENEWABLE<br />

ENERGY PRODUCTS<br />

D<br />

1/4-20 THREADED<br />

Right Left Front Back<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 19-5


Renewable Energy Products<br />

Revised on 06/30/19<br />

VersiCharge Technical Features<br />

Technical Features<br />

Attribute<br />

Hardwired<br />

Model<br />

Universal<br />

Model<br />

Wi-Fi Model with option<br />

to customize module<br />

Wi-Fi Model with<br />

included module<br />

Wi-Fi and OCPP<br />

enable Model<br />

Essentials Part Number VC30GRYHW VC30GRYU VCSG30GRYU VCSG30GRYUW VCSG30GCPUW<br />

Input voltage<br />

Output Amperage<br />

Outpout power<br />

208 - 240 VAC<br />

30 Amps<br />

1.8 kW to 7.2 kW<br />

Standby Power Less than 6 Watts Less than 9 Watts<br />

Cord length 14 ft. 20 ft.<br />

Wall weight 12.5 lbs. 14.5 lbs.<br />

Dimensions<br />

14.5”W x 16.0”H x 6.5”D<br />

Enclosure NEMA 1 NEMA 4<br />

Plug in installation No Yes (below or behind unit)<br />

Permanent<br />

installation<br />

Yes<br />

Communication<br />

hardware<br />

N/A<br />

CTA2045 Interface<br />

without communication<br />

module<br />

CTA2045 Interface with<br />

communication module<br />

Network connection N/A Optional Wi-Fi Wi-Fi with OCPP<br />

Radio N/A Optional High Performing 2.4 GHz IEEE 802.11 b/g/n<br />

Connectivity<br />

N/A<br />

Communicated to<br />

vendor specific cloud<br />

Communicated<br />

through local wireless<br />

network to VersiCharge<br />

SG Cloud<br />

Communication through<br />

local wireless network<br />

to preferred OCPP<br />

networking back-end<br />

Metering accuracy N/A +/- 0.5% standard (custom precision variant available)<br />

Reporting parameters N/A Power consumption, status, events<br />

Demand response<br />

compatible<br />

Yes, with accessory<br />

Yes, with appropriate<br />

communications<br />

module<br />

Yes, with Opt-in<br />

Electrical Circuit requirement 40 Amperes* 40 Amperes**<br />

Infrastructure Plug NEMA 6-50<br />

Input power<br />

connections<br />

Line 1, Line 2, Earth Ground<br />

Mechanical<br />

Safety and<br />

Operational<br />

Recommended<br />

branch break<br />

Connector<br />

40 Ampere double pole (Siemens: Q240 plug in type, B240 bolt on type)<br />

SAE J1772<br />

Standards compliance UL, SAE J1772, NEC ® 625<br />

19<br />

EMC<br />

Operating temperature<br />

FCC Part 15 Class B<br />

-30°C to +50°C<br />

RENEWABLE<br />

ENERGY PRODUCTS<br />

Electric<br />

Vehicles<br />

Tested<br />

Storage temperature<br />

Operating humidity<br />

Ground fault detection<br />

Vehicles<br />

-40°C to +60°C<br />

Maximum 95% non-condensing<br />

5 mA CCID with auto retry<br />

BMW i3, BMW i8, Ford Focus Electric, Nissan Leaf, Mercedes B Class, Fiat 500e, GM Volt<br />

19-6<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Renewable Energy Products<br />

Revised on 06/30/19<br />

VersiComm Cellular Gateway<br />

VersiComm: Cellular Gateway for Wi-Fi Enabled<br />

VersiCharge Electric Vehicle Chargers.<br />

All VersiComm devices feature:<br />

n Cellular Connection: The Siemens VersiComm device<br />

is an all-in-one multiprotocol intelligent node solution for<br />

both Wi-Fi and cellular networks. This allows VersiCharge<br />

SG units with Wi-Fi to connect to the node and have their<br />

data sent to the cloud using 4G LTE cellular data.<br />

n Scalable: A single VersiComm allows for up to 25<br />

VersiCharge SG units to connect to it. This future-proofs<br />

EV charging investments since extra VersiCharge SG<br />

units can be easily added to installations without the need<br />

for more cellular modems.<br />

n Convenient: VersiComm takes the data from multiple<br />

VersiCharge SG units and sends the data to the cloud<br />

using one 4GLTE data plan. This allows charging<br />

deployment owners to avoid having to keep track of<br />

multiple cellular plans at their chosen installation.<br />

n Robust Construction: The housing of the VersiComm<br />

is rated at NEMA 4 for indoor and outdoor use. The<br />

electronics inside the VersiComm unit are rated for an<br />

internal operating temperature range of - 25°C to +70°C.<br />

n Easy Installation: The VersiComm unit comes ready to<br />

operate when shipped. Two ordering variants include<br />

options for either 120V or 240V installations.<br />

n Dependable: Each VersiComm unit meets strict UL and<br />

FCC standards to ensure that the unit is built-to-last.<br />

Ordering Variants<br />

Catalog No. Description Voltage<br />

VC1COMMA VersiComm 4G LTE ATT 120V<br />

VC2COMMA VersiComm 4G LTE ATT 240V<br />

Catalog No. Data Plan<br />

VCDATA53 ATT 5GB Data Plan for 3 years<br />

VCDATA55 ATT 5GB Data Plan for 5 years<br />

VCDATA103 ATT 10GB Data Plan for 3 years<br />

VCDATA105 ATT 10GB Data Plan for 5 years<br />

VCDATA153 ATT 15GB Data Plan for 3 years<br />

VCDATA155 ATT 15GB Data Plan for 5 years<br />

Technical information<br />

Attribute VC1COMMA VC2COMMA<br />

Input voltage 120VAC 220/240VAC<br />

Wall weight 25 lbs. 25 lbs.<br />

Dimensions 12”W x 16”H x 10”D (not including antenna dimensions) 12”W x 16”H x 10”D (not including antenna dimensions)<br />

Standards Compliance UL 508, CSA 22.2 No. 107.1 UL 508, CSA 22.2 No. 107.1<br />

Enclosure NEMA 4 NEMA 4<br />

Plug in installation No No<br />

Permanent installation Yes Yes<br />

Temperature Range -25°C to +70°C -25°C to +70°C<br />

Operating Humidity 5% to 95% relative humidity (non-condensing) 5% to 95% relative humidity (non-condensing)<br />

Network connection 4G LTE 4G LTE<br />

Radio High Performing 2.4 GHz IEEE 802.11 b/g/n High Performing 2.4 GHz IEEE 802.11 b/g/n<br />

Compatible Chargers VCSG30GRYUW, VCSG30GCPUW VCSG30GRYUW, VCSG30GCPUW<br />

19 RENEWABLE<br />

ENERGY PRODUCTS<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 19-7


Renewable Energy Products<br />

Revised on 06/30/19<br />

Siemens Microinverters<br />

Please note: Siemens has discontinued<br />

the following products:<br />

n Siemens Microinverter*<br />

n Siemens Microinverter System*<br />

n Microinverter Trunk and Drop Cabling*<br />

n Envoy Microinverter System Components*<br />

n Microinverter Accessories*<br />

* Discontinued (Spare parts available for Warranty purposes)<br />

In 2019, we have started the phase out process and will eventually<br />

complete it for all the part numbers.<br />

The following is what to expect during this phase out process.<br />

1. No new orders will be taken on these products effective<br />

immediately.<br />

2. Requirements for replacement parts will continue to be supported<br />

for product under warranty. The timing of the support is calculated<br />

based on existing warranty commitments as well as expected<br />

normal product mortality life.<br />

If you have any questions about this announcement or have the need<br />

for replacement parts for an existing system, please contact your<br />

Siemens sales representative for more information and assistance.<br />

RENEWABLE<br />

ENERGY PRODUCTS<br />

19<br />

19-8<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

050BB1224J 8-22<br />

050BB1632J 8-23<br />

050BB2448J 8-24<br />

100BB1224J 8-22<br />

100BB1632J 8-23<br />

100BB2448J 8-24<br />

105BB1224J 8-22<br />

105BB1632J 8-23<br />

105BB2448J 8-24<br />

11 Series Starters and Switches<br />

17-10, 17-11<br />

12CLN500 7-195, 7-213<br />

14 Series NEMA Control<br />

17-15, 17-16,<br />

150BB1224J 8-22<br />

150BB1632J 8-23<br />

150BB2448J 8-24<br />

17 Series NEMA Combination<br />

Starters 17-19, 17-20, 17-21<br />

18 Series NEMA Combination<br />

Starters 17-22, 17-23<br />

1B1N001 8-9<br />

1B1N002 8-9<br />

1B1N003 8-9<br />

1B1N005 8-9<br />

1B1N007 8-9<br />

1B1N010 8-9<br />

1B1N015 8-9<br />

1B1S050TP1 8-9<br />

1B1S075TP1 8-9<br />

1B1S100TP1 8-9<br />

1B1S167TP1 8-9<br />

1B1Y015TP1 8-9<br />

1B1Y025TP1 8-9<br />

1B1Y037TP1 8-9<br />

1BB1224J 8-22<br />

1BB1632J 8-23<br />

1BB2448J 8-24<br />

1D1N001 8-9<br />

1D1N002 8-9<br />

1D1N003 8-9<br />

1D1N005 8-9<br />

1D1N007 8-9<br />

1D1N010 8-9<br />

1D1N015 8-9<br />

1D1N105 8-9<br />

1D1N205 8-9<br />

1D1N505 8-9<br />

1D1N705 8-9<br />

1D1Y015TP1 8-9<br />

1D1Y025TP1 8-9<br />

1D1Y037TP1 8-9<br />

1D1Y050TP1 8-9<br />

1D1Y075TP1 8-9<br />

1D1Y100TP1 8-9<br />

1D1Y167TP1 8-9<br />

1E1U003 8-9<br />

1E1U005 8-9<br />

1E1U007 8-9<br />

1E1U010 8-9<br />

1E1U015 8-9<br />

1E1U025 8-9<br />

1F1R003 8-9<br />

1F1R005 8-9<br />

1F1R007 8-9<br />

1F1R010 8-9<br />

1F1R015 8-9<br />

1F1R025 8-9<br />

1G1R003 8-10<br />

1G1R005 8-10<br />

1G1R007 8-10<br />

1G1R010 8-10<br />

1G1R015 8-10<br />

1G1R025 8-10<br />

1G1T025TP1 8-10<br />

1G1T037TP1 8-10<br />

1G1T050TP1 8-10<br />

1G1T075TP1 8-10<br />

1G1T100TP1 8-10<br />

1G1T167TP1 8-10<br />

1H1N001 8-10<br />

1H1N002 8-10<br />

1H1N003 8-10<br />

1H1N005 8-10<br />

1H1N007 8-10<br />

1H1N010 8-10<br />

1H1N015 8-10<br />

1H1N025 8-10<br />

1H8N001 8-10<br />

1H8N002 8-10<br />

1H8N003 8-10<br />

1H8N005 8-10<br />

1H8N007 8-10<br />

1LPC005 8-16<br />

1LPC005JA 8-17<br />

1LPC007 8-16<br />

1LPC007JA 8-17<br />

1LPC010 8-16<br />

1LPC010JA 8-17<br />

1LPC015 8-16<br />

1LPC015JA 8-17<br />

1LPC025 8-16<br />

1LPC025JA 8-17<br />

1X1N001 8-10<br />

1X1N002 8-10<br />

1X1N003 8-10<br />

1X1N005 8-10<br />

1X1N007 8-10<br />

1X1N010 8-10<br />

1X1N015 8-10<br />

1X1N025 8-10<br />

205BB1224J 8-22<br />

205BB1632J 8-23<br />

205BB2448J 8-24<br />

22 Series NEMA Reversing Starters<br />

17-24<br />

24B4X26 11-25<br />

24B4X32 11-25<br />

24B4X38 11-25<br />

24B4X44 11-25<br />

24B4X50 11-25<br />

24B4X56 11-25<br />

24B4X62 11-25<br />

24B4X68 11-25<br />

24B4X74 11-25<br />

24NRD56 11-49<br />

24NRD62 11-49<br />

24NRD68 11-49<br />

24NRD74 11-49<br />

24NRD80 11-49<br />

24WD56 11-49<br />

24WD62 11-49<br />

24WD68 11-49<br />

24WD74 11-49<br />

24WD80 11-49<br />

24WPD56 11-49<br />

24WPD62 11-49<br />

24WPD68 11-49<br />

24WPD74 11-49<br />

24WPD80 11-49<br />

25 Series NEMA Combination<br />

Reversing Starters 17-25<br />

26 Series NEMA Combination<br />

Reversing Starters 17-26<br />

2BB1224J 8-22<br />

2BB1632J 8-23<br />

2BB2448J 8-24<br />

2CLD20 7-175, 7-212<br />

2NLK1 11-15<br />

2NLK18 11-11, 11-22<br />

2NLK2 11-15<br />

2NLK30 11-11, 11-22<br />

2NLK30A 11-11, 11-22<br />

2NLK42 11-11, 11-22<br />

2NLK42A 11-11, 11-22<br />

2NLK54A 11-11, 11-22<br />

2TA2N8750 7-128, 7-132, 7-155<br />

2TA3N8750 7-128, 7-132, 7-155<br />

2TA3NG750 7-213<br />

2TA4N8500 6-6, 7-128, 7-132, 7-154<br />

2TA4NG500 7-213<br />

2TA4P8500 7-128, 7-132, 7-154<br />

30 Series NEMA Two Speed<br />

Starters 17-28, 17-29<br />

32 Series Combination Two Speed<br />

Starters 17-31, 17-32, 17-33<br />

36 & 37 Series Auto Transformer<br />

Starters 17-35, 17-36, 17-37, 17-38<br />

36 & 37 Series Part Winding<br />

Starters 17-39, 17-40, 17-41, 17-42<br />

36 & 37 Series Wye Delta Open<br />

Starters 17-43, 17-44, 17-45, 17-46<br />

36 & 37 Series Wye Delta Closed<br />

Starters 17-47, 17-48, 17-49, 17-50<br />

3B1M150D16 8-13<br />

3B1M225D16 8-13<br />

3B1Y015D16 8-13<br />

3B1Y030D16 8-13<br />

3B1Y045D16 8-13<br />

3B1Y075D16 8-13<br />

3B1Y112D16 8-13<br />

3B3M150D16 8-13<br />

3B3M225D16 8-13<br />

3B3M300D16 8-13<br />

3B3M500D16 8-13<br />

3B3R003 8-13<br />

3B3R006 8-13<br />

3B3R009 8-13<br />

3B3R015 8-13<br />

3B3Y015D16 8-13<br />

3B3Y030D16 8-13<br />

3B3Y045D16 8-13<br />

3B3Y075D16 8-13<br />

3B3Y112D16 8-13<br />

3B5M150D16 8-13<br />

3B5M225D16 8-13<br />

3B5M300D16 8-13<br />

3B5M500D16 8-13<br />

3B5R009 8-13<br />

3B5R015 8-13<br />

3B5Y015D16 8-13<br />

3B5Y030D16 8-13<br />

3B5Y045D16 8-13<br />

3B5Y075D16 8-13<br />

3B5Y112D16 8-13<br />

3BB1224J 8-22<br />

3BB1632J 8-23<br />

3BB2448J 8-24<br />

3C3M225D16 8-13<br />

3C3M300D16 8-13<br />

3C3M500D16 8-13<br />

3C3Y015D16 8-13<br />

3C3Y030D16 8-13<br />

3C3Y045D16 8-13<br />

3C3Y075D16 8-13<br />

3C3Y112D16 8-13<br />

3C3Y150D16 8-13<br />

3C5M225D16 8-13<br />

3C5M300D16 8-13<br />

3C5M500D16 8-13<br />

3C5Y015D16 8-13<br />

3C5Y030D16 8-13<br />

3C5Y045D16 8-13<br />

3C5Y075D16 8-13<br />

3C5Y112D16 8-13<br />

3C5Y150D16 8-13<br />

3CLD20 7-175, 7-212<br />

3CLJ350 7-183, 7-213<br />

3CLJ600 7-183, 7-213<br />

3CLL750 7-187, 7-213<br />

3F1T500D16 8-11<br />

3F1T750D16 8-11<br />

3F1Y015D16 8-11<br />

3F1Y015TE 8-11<br />

3F1Y030D16 8-11<br />

3F1Y030TE 8-11<br />

3F1Y045D16 8-11<br />

3F1Y045TE 8-11<br />

3F1Y075D16 8-11<br />

3F1Y075TE 8-11<br />

3F1Y112D16 8-11<br />

3F1Y112TE 8-11<br />

3F1Y150D16 8-11<br />

3F1Y150TE 8-11<br />

3F1Y225D16 8-11<br />

3F1Y225TE 8-11<br />

3F1Y300D16 8-11<br />

3F1Y300TE 8-11<br />

3F2R003 8-11<br />

3F2R006 8-11<br />

3F2R009 8-11<br />

3F2R015 8-11<br />

3F3R003 8-11<br />

3F3R006 8-11<br />

3F3R009 8-11<br />

3F3R015 8-11<br />

3F3T000D16 8-11<br />

3F3T500D16 8-11<br />

3F3T500K13D16 8-12<br />

3F3T500K20D16 8-12<br />

3F3T500K30D16 8-12<br />

3F3T500K4D16 8-12<br />

3F3T750D16 8-11<br />

3F3Y015BCHD100 8-20<br />

3F3Y015BCHD130 8-20<br />

3F3Y015CHD100 8-20<br />

3F3Y015CHD130 8-20<br />

3F3Y015D16 8-11<br />

3F3Y015FCHD100 8-20<br />

3F3Y015FCHD130 8-20<br />

3F3Y015K13D16 8-12<br />

3F3Y015K20D16 8-12<br />

3F3Y015K30D16 8-12<br />

3F3Y015K4D16 8-12<br />

3F3Y015TE 8-11<br />

3F3Y030BCHD100 8-20<br />

3F3Y030BCHD130 8-20<br />

3F3Y030CHD100 8-20<br />

3F3Y030CHD130 8-20<br />

3F3Y030D16 8-11<br />

3F3Y030FCHD100 8-20<br />

3F3Y030FCHD130 8-20<br />

3F3Y030K13D16 8-12<br />

3F3Y030K20D16 8-12<br />

3F3Y030K30D16 8-12<br />

3F3Y030K4D16 8-12<br />

3F3Y030TE 8-11<br />

3F3Y045BCHD100 8-20<br />

3F3Y045BCHD130 8-20<br />

3F3Y045CHD100 8-20<br />

3F3Y045CHD130 8-20<br />

3F3Y045D16 8-11<br />

3F3Y045FCHD100 8-20<br />

3F3Y045FCHD130 8-20<br />

3F3Y045K13D16 8-12<br />

3F3Y045K20D16 8-12<br />

3F3Y045K30D16 8-12<br />

3F3Y045K4D16 8-12<br />

3F3Y045TE 8-11<br />

3F3Y075BCHD100 8-20<br />

3F3Y075BCHD130 8-20<br />

3F3Y075CHD100 8-20<br />

3F3Y075CHD130 8-20<br />

3F3Y075D16 8-11<br />

3F3Y075FCHD100 8-20<br />

3F3Y075FCHD130 8-20<br />

3F3Y075K13D16 8-12<br />

3F3Y075K20D16 8-12<br />

3F3Y075K30D16 8-12<br />

3F3Y075K4D16 8-12<br />

3F3Y075TE 8-11<br />

3F3Y112BCHD100 8-20<br />

3F3Y112BCHD130 8-20<br />

3F3Y112CHD100 8-20<br />

3F3Y112CHD130 8-20<br />

3F3Y112D16 8-11<br />

3F3Y112FCHD100 8-20<br />

3F3Y112FCHD130 8-20<br />

3F3Y112K13D16 8-12<br />

3F3Y112K20D16 8-12<br />

3F3Y112K30D16 8-12<br />

3F3Y112K4D16 8-12<br />

3F3Y112TE 8-11<br />

3F3Y150BCHD100 8-20<br />

3F3Y150BCHD130 8-20<br />

3F3Y150CHD100 8-20<br />

3F3Y150CHD130 8-20<br />

3F3Y150D16 8-11<br />

3F3Y150FCHD100 8-20<br />

3F3Y150FCHD130 8-20<br />

3F3Y150K13D16 8-12<br />

3F3Y150K20D16 8-12<br />

3F3Y150K30D16 8-12<br />

3F3Y150K4D16 8-12<br />

3F3Y150TE 8-11<br />

3F3Y225BCHD100 8-20<br />

3F3Y225BCHD130 8-20<br />

3F3Y225CHD100 8-20<br />

3F3Y225CHD130 8-20<br />

3F3Y225D16 8-11<br />

3F3Y225FCHD100 8-20<br />

3F3Y225FCHD130 8-20<br />

3F3Y225K13D16 8-12<br />

3F3Y225K20D16 8-12<br />

3F3Y225K30D16 8-12<br />

3F3Y225K4D16 8-12<br />

3F3Y225TE 8-11<br />

3F3Y300BCHD100 8-20<br />

3F3Y300BCHD130 8-20<br />

3F3Y300CHD100 8-20<br />

3F3Y300CHD130 8-20<br />

3F3Y300D16 8-11<br />

3F3Y300FCHD100 8-20<br />

3F3Y300FCHD130 8-20<br />

3F3Y300K13D16 8-12<br />

3F3Y300K20D16 8-12<br />

3F3Y300K30D16 8-12<br />

3F3Y300K4D16 8-12<br />

3F3Y300TE 8-11<br />

3F3Y500BCHD100 8-20<br />

3F3Y500BCHD130 8-20<br />

3F3Y500CHD100 8-20<br />

3F3Y500CHD130 8-20<br />

3F3Y500FCHD100 8-20<br />

3F3Y500FCHD130 8-20<br />

3F5R015 8-12<br />

3F5T500D16 8-12<br />

3F5Y015D16 8-12<br />

3F5Y030D16 8-12<br />

3F5Y045D16 8-12<br />

3F5Y075D16 8-12<br />

3F5Y112D16 8-12<br />

3F5Y150D16 8-12<br />

3F5Y225D16 8-12<br />

3F5Y300D16 8-12<br />

3G3R003 8-14<br />

3G3R006 8-14<br />

3G3R009 8-14<br />

3G3R015 8-14<br />

3G3T015D16 8-14<br />

3G3T030D16 8-14<br />

3G3T045D16 8-14<br />

3G3T075D16 8-14<br />

3G3T112D16 8-14<br />

3G3T150D16 8-14<br />

3G3T225D16 8-14<br />

3G3T300D16 8-14<br />

3G3T500D16 8-14<br />

3G4N015A 8-14<br />

3G4N030A 8-14<br />

3G4N045A 8-14<br />

3G4N075A 8-14<br />

3G4N112A 8-14<br />

3G4N150A 8-14<br />

3G4N225A 8-14<br />

3G4N300A 8-14<br />

3G4N500A 8-14<br />

3G5R003 8-14<br />

3G5R006 8-14<br />

3G5R009 8-14<br />

3G5R015 8-14<br />

3G5T015D16 8-14<br />

3G5T030D16 8-14<br />

3G5T045D16 8-14<br />

3G5T075D16 8-14<br />

3G5T112D16 8-14<br />

3G5T150D16 8-14<br />

3G5T225D16 8-14<br />

3G5T300D16 8-14<br />

3G5T500D16 8-14<br />

3LD20 5-4<br />

3LD2003-1TP53 5-2<br />

3LD2013-0TK5 5-3<br />

3LD<strong>2017</strong>-0TK1 5-3<br />

3LD<strong>2017</strong>-1TL1 5-3<br />

3LD2064 4-35, 5-6<br />

3LD2064-0TB51-0US2 4-34, 5-5<br />

3LD2064-0TB53-0US2 4-34, 5-5<br />

3LD2064-1GP51-0US2 4-34, 5-5<br />

3LD2064-1GP53-0US2 4-34, 5-5<br />

3LD21 5-4<br />

3LD2103-0TK 5-2<br />

3LD2103-1TL 5-2<br />

3LD2103-1TP 5-2<br />

3LD2103-2EP 5-2<br />

3LD2113-0TK5 5-3<br />

3LD2113-1TL5 5-3<br />

3LD2144-0TK5 5-3<br />

3LD2144-1TL5 5-3<br />

3LD2154-0TK 5-2<br />

3LD2154-1TL 5-2<br />

3LD2154-1TP 5-2<br />

3LD2154-2EP 5-2<br />

3LD2164 4-35, 5-6<br />

3LD2164-0TB51-0US2 4-34, 5-5<br />

3LD2164-0TB53-0US2 4-34, 5-5<br />

3LD2164-1GP51-0US2 4-34, 5-5<br />

3LD2164-1GP53-0US2 4-34, 5-5<br />

3LD22 5-4<br />

3LD2203-0TK 5-2<br />

3LD2203-1TL 5-2<br />

3LD2213-0TK5 5-3<br />

3LD2213-1TL53 5-3<br />

3LD2217-0TK1 5-3<br />

3LD2217-1TL1 5-3<br />

3LD2244-0TK5 5-3<br />

3LD2244-1TL53 5-3<br />

3LD2254-0TK 5-2<br />

I<br />

PRODUCT<br />

INDEX<br />

(Section was last modified on 09/28/20)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog I-1


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

I<br />

PRODUCT<br />

INDEX<br />

3LD2254-1TL 5-2<br />

3LD2264 4-35, 5-6<br />

3LD2264-0TB51-0US2 4-34, 5-5<br />

3LD2264-0TB53-0US2 4-34, 5-5<br />

3LD2264-1GP51-0US2 4-34, 5-5<br />

3LD2264-1GP53-0US2 4-34, 5-5<br />

3LD2264-1TS51-0US2 4-34, 5-5<br />

3LD2264-1TS53-0US2 4-34, 5-5<br />

3LD2264-2TW51-0US2 4-34, 5-5<br />

3LD2264-2TW53-0US2 4-34, 5-5<br />

3LD23 5-4<br />

3LD2318-0TK1 5-3<br />

3LD24 5-4<br />

3LD2418-0TK1 5-3<br />

3LD25 5-4<br />

3LD2504-0TK 5-2<br />

3LD2514-0TK5 5-3<br />

3LD2517-0TK1 5-3<br />

3LD2517-1TL1 5-3<br />

3LD2545-0TK5 5-3<br />

3LD2555-0TK 5-2<br />

3LD2565 4-35, 5-6<br />

3LD2565-0TB51-0US2 4-34, 5-5<br />

3LD2565-0TB53-0US2 4-34, 5-5<br />

3LD2565-1GP51-0US2 4-34, 5-5<br />

3LD2565-1GP53-0US2 4-34, 5-5<br />

3LD27 5-4<br />

3LD2704-0TK 5-2<br />

3LD2714-0TK5 5-3<br />

3LD2766 4-35, 5-6<br />

3LD2766-0TB51-0US2 4-34, 5-5<br />

3LD2766-0TB53-0US2 4-34, 5-5<br />

3LD2766-1GP51-0US2 4-34, 5-5<br />

3LD2766-1GP53-0US2 4-34, 5-5<br />

3LD28 5-4<br />

3LD2804-0TK 5-2<br />

3LD2814-0TK5 5-3<br />

3LD2866 4-35, 5-6<br />

3LD2866-0TB51-0US2 4-34, 5-5<br />

3LD2866-0TB53-0US2 4-34, 5-5<br />

3LD2866-1GP51-0US2 4-34, 5-5<br />

3LD2866-1GP53-0US2 4-34, 5-5<br />

3LD9200-5B 5-3<br />

3LD9200-5BF 5-3<br />

3LD9200-5C 5-3<br />

3LD9200-5CF 5-3<br />

3LD9220-0B 5-3<br />

3LD9220-0C 5-3<br />

3LD9220-2B 5-3<br />

3LD9220-2C 4-35, 5-3, 5-6<br />

3LD9221-0A 5-3<br />

3LD9221-2A 5-3<br />

3LD9224-1B 5-3<br />

3LD9224-1D 5-3<br />

3LD9224-3B 5-3<br />

3LD9224-3D 5-3<br />

3LD9240-0C 5-3<br />

3LD9240-2C 5-3<br />

3LD9250-0BA 5-3<br />

3LD9250-0CA 5-3<br />

3LD9250-2BA 5-3<br />

3LD9250-2CA 4-35, 5-3, 5-6<br />

3LD9251-0A 5-3<br />

3LD9280-0B 5-3<br />

3LD9280-0C 5-3<br />

3LD9280-2B 5-3<br />

3LD9280-2C 4-35, 5-3, 5-6<br />

3LD9284-1B 5-3<br />

3LD9284-1D 5-3<br />

3LD9284-3B 5-3<br />

3LD9284-3D 5-3<br />

3LPC009 8-16<br />

3LPC009JA 8-17<br />

3LPC015 8-16<br />

3LPC015JA 8-17<br />

3LPC022 8-16<br />

3LPC022JA 8-17<br />

3LPC030 8-16<br />

3LPC030JA 8-17<br />

3PE21 1-14<br />

3PE30 1-14<br />

3PE36 1-14<br />

3PE39 1-14<br />

3PE42 1-14<br />

3PE49 1-14<br />

3RE4 Reversing Starter 17-180,<br />

17-181, 17-182, 17-183, 17-184, 17-185<br />

3RW30 Soft Starter 17-198<br />

3RW40 Soft Starter 17-202<br />

17-203, 17-204<br />

3RW44 Soft Starter 17-210<br />

17-211, 17-212<br />

3TA12JG04 7-183, 7-213<br />

3TA1DG30 7-175, 7-212<br />

3TA1JG750 7-183, 7-213<br />

3TA1QR300 7-154, 7-40<br />

3TA2JG250 7-183, 7-213<br />

3TA2LG600LD 7-187, 7-213<br />

3TA2LG600LN 7-187, 7-213<br />

3TA2LG600LNPT 7-213<br />

3TA2MG750 7-191, 7-213<br />

3TA2N8750 7-128, 7-130, 7-132, 7-155<br />

3TA3DG02 7-175, 7-212<br />

3TA3FG20 7-212<br />

3TA3MG500 7-191, 7-213<br />

3TA3MG600 7-191, 7-213<br />

3TA3N8750 7-128, 7-130, 7-132, 7-155<br />

3TA3NG750 7-195, 7-213<br />

3TA4N8500 6-6, 6-7, 7-128, 7-130,<br />

7-132, 7-154<br />

3TA4NG500 7-195, 7-213<br />

3TA4NG500H 7-195, 7-213<br />

3TA4NG500PT 7-213<br />

3TA4P8500 7-128, 7-130, 7-132, 7-154<br />

3TA6DG04 7-175, 7-212<br />

3TA6FG04 7-212<br />

3TA6JG20 7-183, 7-213<br />

3TA6PG750 7-199, 7-213<br />

3TAW1FG350 7-212<br />

3TC1DG30 7-175, 7-212<br />

3TC1GG20 6-3, 7-153, 7-33, 7-34, 7-43<br />

3TC1Q1 6-3, 7-153, 7-33, 7-34, 7-43<br />

3TC1QR250 7-40<br />

3TC1QR2520 7-155<br />

3TC2LG600LD 7-187, 7-213<br />

3TC2LG600LN 7-187, 7-213<br />

3TC4NG500 7-195, 7-213<br />

3TCW1FG350 7-212<br />

3TW1DG20 7-175, 7-212<br />

3TW1FG350 7-212<br />

3TW1JG600 7-183, 7-213<br />

3UF79100AA000 7-216, 7-217<br />

3VA4110-4ED14-0AA0 11-60, 7-36<br />

3VA4110-4ED24-0AA0 11-61, 7-36<br />

3VA4110-4ED34-0AA0 11-61, 7-37<br />

3VA4110-4ED54-0AA0 11-60<br />

3VA4110-4ED54-0AA0 7-36<br />

3VA4110-5ED14-0AA0 11-60, 7-36<br />

3VA4110-5ED24-0AA0 11-61, 7-36<br />

3VA4110-5ED34-0AA0 11-61, 7-37<br />

3VA4110-5ED54-0AA0 11-60<br />

3VA4110-5ED54-0AA0 7-36<br />

3VA4110-6ED14-0AA0 11-60, 7-36<br />

3VA4110-6ED24-0AA0 11-61, 7-36<br />

3VA4110-6ED34-0AA0 11-61, 7-37<br />

3VA4110-6ED54-0AA0 11-60<br />

3VA4110-6ED54-0AA0 7-36<br />

3VA4111-4ED14-0AA0 11-60, 7-36<br />

3VA4111-4ED24-0AA0 11-61, 7-36<br />

3VA4111-4ED34-0AA0 11-61, 7-37<br />

3VA4111-4ED54-0AA0 11-60<br />

3VA4111-4ED54-0AA0 7-36<br />

3VA4111-5ED14-0AA0 11-60, 7-36<br />

3VA4111-5ED24-0AA0 11-61, 7-36<br />

3VA4111-5ED34-0AA0 11-61, 7-37<br />

3VA4111-5ED54-0AA0 11-60<br />

3VA4111-5ED54-0AA0 7-36<br />

3VA4111-6ED14-0AA0 11-60, 7-36<br />

3VA4111-6ED24-0AA0 11-61, 7-36<br />

3VA4111-6ED34-0AA0 11-61, 7-37<br />

3VA4111-6ED54-0AA0 11-60<br />

3VA4111-6ED54-0AA0 7-36<br />

3VA4112-4ED14-0AA0 11-60, 7-36<br />

3VA4112-4ED24-0AA0 11-61, 7-36<br />

3VA4112-4ED34-0AA0 11-61, 7-37<br />

3VA4112-4ED54-0AA0 11-60<br />

3VA4112-4ED54-0AA0 7-36<br />

3VA4112-5ED14-0AA0 11-60, 7-36<br />

3VA4112-5ED24-0AA0 11-61, 7-36<br />

3VA4112-5ED34-0AA0 11-61, 7-37<br />

3VA4112-5ED54-0AA0 11-60<br />

3VA4112-5ED54-0AA0 7-36<br />

3VA4112-6ED14-0AA0 11-60, 7-36<br />

3VA4112-6ED24-0AA0 11-61, 7-36<br />

3VA4112-6ED34-0AA0 11-61, 7-37<br />

3VA4112-6ED54-0AA0 11-60<br />

3VA4112-6ED54-0AA0 7-36<br />

3VA4120-4ED14-0AA0 11-60, 7-36<br />

3VA4120-4ED24-0AA0 11-61, 7-36<br />

3VA4120-4ED34-0AA0 11-61, 7-37<br />

3VA4120-4ED54-0AA0 11-60<br />

3VA4120-4ED54-0AA0 7-36<br />

3VA4120-5ED14-0AA0 11-60, 7-36<br />

3VA4120-5ED24-0AA0 11-61, 7-36<br />

3VA4120-5ED34-0AA0 11-61, 7-37<br />

3VA4120-5ED54-0AA0 11-60<br />

3VA4120-5ED54-0AA0 7-36<br />

3VA4120-6ED14-0AA0 11-60, 7-36<br />

3VA4120-6ED24-0AA0 11-61, 7-36<br />

3VA4120-6ED34-0AA0 11-61, 7-37<br />

3VA4120-6ED54-0AA0 11-60<br />

3VA4120-6ED54-0AA0 7-36<br />

3VA4125-4ED14-0AA0 11-60, 7-36<br />

3VA4125-4ED24-0AA0 11-61, 7-36<br />

3VA4125-4ED34-0AA0 11-61, 7-37<br />

3VA4125-4ED54-0AA0 11-60<br />

3VA4125-4ED54-0AA0 7-36<br />

3VA4125-5ED14-0AA0 11-60, 7-36<br />

3VA4125-5ED24-0AA0 11-61, 7-36<br />

3VA4125-5ED34-0AA0 11-61, 7-37<br />

3VA4125-5ED54-0AA0 11-60<br />

3VA4125-5ED54-0AA0 7-36<br />

3VA4125-6ED14-0AA0 11-60, 7-36<br />

3VA4125-6ED24-0AA0 11-61, 7-36<br />

3VA4125-6ED34-0AA0 11-61, 7-37<br />

3VA4125-6ED54-0AA0 11-60<br />

3VA4125-6ED54-0AA0 7-36<br />

3VA4130-4ED14-0AA0 11-60, 7-36<br />

3VA4130-4ED24-0AA0 11-61, 7-36<br />

3VA4130-4ED34-0AA0 11-61, 7-37<br />

3VA4130-4ED54-0AA0 11-60<br />

3VA4130-4ED54-0AA0 7-36<br />

3VA4130-5ED14-0AA0 11-60, 7-36<br />

3VA4130-5ED24-0AA0 11-61, 7-36<br />

3VA4130-5ED34-0AA0 11-61, 7-37<br />

3VA4130-5ED54-0AA0 11-60<br />

3VA4130-5ED54-0AA0 7-36<br />

3VA4130-6ED14-0AA0 11-60, 7-36<br />

3VA4130-6ED24-0AA0 11-61, 7-36<br />

3VA4130-6ED34-0AA0 11-61, 7-37<br />

3VA4130-6ED54-0AA0 11-60<br />

3VA4130-6ED54-0AA0 7-36<br />

3VA4135-4ED14-0AA0 11-60, 7-36<br />

3VA4135-4ED24-0AA0 11-61, 7-36<br />

3VA4135-4ED34-0AA0 11-61, 7-37<br />

3VA4135-4ED54-0AA0 11-60<br />

3VA4135-4ED54-0AA0 7-36<br />

3VA4135-5ED14-0AA0 11-60, 7-36<br />

3VA4135-5ED24-0AA0 11-61, 7-36<br />

3VA4135-5ED34-0AA0 11-61, 7-37<br />

3VA4135-5ED54-0AA0 11-60<br />

3VA4135-5ED54-0AA0 7-36<br />

3VA4135-6ED14-0AA0 11-60, 7-36<br />

3VA4135-6ED24-0AA0 11-61, 7-36<br />

3VA4135-6ED34-0AA0 11-61, 7-37<br />

3VA4135-6ED54-0AA0 11-60<br />

3VA4135-6ED54-0AA0 7-36<br />

3VA4140-4ED14-0AA0 11-60, 7-36<br />

3VA4140-4ED24-0AA0 11-61, 7-36<br />

3VA4140-4ED34-0AA0 11-61, 7-37<br />

3VA4140-4ED54-0AA0 11-60<br />

3VA4140-4ED54-0AA0 7-36<br />

3VA4140-5ED14-0AA0 11-60, 7-36<br />

3VA4140-5ED24-0AA0 11-61, 7-36<br />

3VA4140-5ED34-0AA0 11-61, 7-37<br />

3VA4140-5ED54-0AA0 11-60<br />

3VA4140-5ED54-0AA0 7-36<br />

3VA4140-6ED14-0AA0 11-60, 7-36<br />

3VA4140-6ED24-0AA0 11-61, 7-36<br />

3VA4140-6ED34-0AA0 11-61, 7-37<br />

3VA4140-6ED54-0AA0 11-60<br />

3VA4140-6ED54-0AA0 7-36<br />

3VA4145-4ED14-0AA0 11-60, 7-36<br />

3VA4145-4ED24-0AA0 11-61, 7-36<br />

3VA4145-4ED34-0AA0 11-61, 7-37<br />

3VA4145-4ED54-0AA0 11-60<br />

3VA4145-4ED54-0AA0 7-36<br />

3VA4145-5ED14-0AA0 11-60, 7-36<br />

3VA4145-5ED24-0AA0 11-61, 7-36<br />

3VA4145-5ED34-0AA0 11-61, 7-37<br />

3VA4145-5ED54-0AA0 11-60<br />

3VA4145-5ED54-0AA0 7-36<br />

3VA4145-6ED14-0AA0 11-60, 7-36<br />

3VA4145-6ED24-0AA0 11-61, 7-36<br />

3VA4145-6ED34-0AA0 11-61, 7-37<br />

3VA4145-6ED54-0AA0 11-60<br />

3VA4145-6ED54-0AA0 7-36<br />

3VA4150-4ED14-0AA0 11-60, 7-36<br />

3VA4150-4ED24-0AA0 11-61, 7-36<br />

3VA4150-4ED34-0AA0 11-61, 7-37<br />

3VA4150-4ED54-0AA0 11-60<br />

3VA4150-4ED54-0AA0 7-36<br />

3VA4150-5ED14-0AA0 11-60, 7-36<br />

3VA4150-5ED24-0AA0 11-61, 7-36<br />

3VA4150-5ED34-0AA0 11-61, 7-37<br />

3VA4150-5ED54-0AA0 11-60<br />

3VA4150-5ED54-0AA0 7-36<br />

3VA4150-6ED14-0AA0 11-60, 7-36<br />

3VA4150-6ED24-0AA0 11-61, 7-36<br />

3VA4150-6ED34-0AA0 11-61, 7-37<br />

3VA4150-6ED54-0AA0 11-60<br />

3VA4150-6ED54-0AA0 7-36<br />

3VA4160-4ED14-0AA0 11-60, 7-36<br />

3VA4160-4ED24-0AA0 11-61, 7-36<br />

3VA4160-4ED34-0AA0 11-61, 7-37<br />

3VA4160-4ED54-0AA0 11-60<br />

3VA4160-4ED54-0AA0 7-36<br />

3VA4160-5ED14-0AA0 11-60, 7-36<br />

3VA4160-5ED24-0AA0 11-61, 7-36<br />

3VA4160-5ED34-0AA0 11-61, 7-37<br />

3VA4160-5ED54-0AA0 11-60<br />

3VA4160-5ED54-0AA0 7-36<br />

3VA4160-6ED14-0AA0 11-60, 7-36<br />

3VA4160-6ED24-0AA0 11-61, 7-36<br />

3VA4160-6ED34-0AA0 11-61, 7-37<br />

3VA4160-6ED54-0AA0 11-60<br />

3VA4160-6ED54-0AA0 7-36<br />

3VA4170-4ED14-0AA0 11-60, 7-36<br />

3VA4170-4ED24-0AA0 11-61, 7-36<br />

3VA4170-4ED34-0AA0 11-61, 7-37<br />

3VA4170-4ED54-0AA0 11-60<br />

3VA4170-4ED54-0AA0 7-36<br />

3VA4170-5ED14-0AA0 11-60, 7-36<br />

3VA4170-5ED24-0AA0 11-61, 7-36<br />

3VA4170-5ED34-0AA0 11-61, 7-37<br />

3VA4170-5ED54-0AA0 11-60<br />

3VA4170-5ED54-0AA0 7-36<br />

3VA4170-6ED14-0AA0 11-60, 7-36<br />

3VA4170-6ED24-0AA0 11-61, 7-36<br />

3VA4170-6ED34-0AA0 11-61, 7-37<br />

3VA4170-6ED54-0AA0 11-60<br />

3VA4170-6ED54-0AA0 7-36<br />

3VA4180-4ED14-0AA0 11-60, 7-36<br />

3VA4180-4ED24-0AA0 11-61, 7-36<br />

3VA4180-4ED34-0AA0 11-61, 7-37<br />

3VA4180-4ED54-0AA0 11-60<br />

3VA4180-4ED54-0AA0 7-36<br />

3VA4180-5ED14-0AA0 11-60, 7-36<br />

3VA4180-5ED24-0AA0 11-61, 7-36<br />

3VA4180-5ED34-0AA0 11-61, 7-37<br />

3VA4180-5ED54-0AA0 11-60<br />

3VA4180-5ED54-0AA0 7-36<br />

3VA4180-6ED14-0AA0 11-60, 7-36<br />

3VA4180-6ED24-0AA0 11-61, 7-36<br />

3VA4180-6ED34-0AA0 11-61, 7-37<br />

3VA4180-6ED54-0AA0 11-60<br />

3VA4180-6ED54-0AA0 7-36<br />

3VA4190-4ED14-0AA0 11-60, 7-36<br />

3VA4190-4ED24-0AA0 11-61, 7-36<br />

3VA4190-4ED34-0AA0 11-61, 7-37<br />

3VA4190-4ED54-0AA0 11-60<br />

3VA4190-4ED54-0AA0 7-36<br />

3VA4190-5ED14-0AA0 11-60, 7-36<br />

3VA4190-5ED24-0AA0 11-61, 7-36<br />

3VA4190-5ED34-0AA0 11-61, 7-37<br />

3VA4190-5ED54-0AA0 11-60<br />

3VA4190-5ED54-0AA0 7-36<br />

3VA4190-6ED14-0AA0 11-60, 7-36<br />

3VA4190-6ED24-0AA0 11-61, 7-36<br />

3VA4190-6ED34-0AA0 11-61, 7-37<br />

3VA4190-6ED54-0AA0 11-60<br />

3VA4190-6ED54-0AA0 7-36<br />

3VA4195-4ED14-0AA0 11-60, 7-36<br />

3VA4195-4ED24-0AA0 11-61, 7-36<br />

3VA4195-4ED34-0AA0 11-61, 7-37<br />

3VA4195-4ED54-0AA0 11-60<br />

3VA4195-4ED54-0AA0 7-36<br />

3VA4195-5ED14-0AA0 11-60, 7-36<br />

3VA4195-5ED24-0AA0 11-61, 7-36<br />

3VA4195-5ED34-0AA0 11-61, 7-37<br />

3VA4195-5ED54-0AA0 11-60<br />

3VA4195-5ED54-0AA0 7-36<br />

3VA4195-6ED14-0AA0 11-60, 7-36<br />

3VA4195-6ED24-0AA0 11-61, 7-36<br />

3VA4195-6ED34-0AA0 11-61, 7-37<br />

3VA4195-6ED54-0AA0 11-60<br />

3VA4195-6ED54-0AA0 7-36<br />

3VA5102-1MH31-0AA0 7-80<br />

3VA5102-1MU31-0AA0 7-80<br />

3VA5103-1MH31-0AA0 7-80<br />

3VA5103-1MU31-0AA0 7-80<br />

3VA5105-1MH31-0AA0 7-80<br />

3VA5105-1MU31-0AA0 7-80<br />

3VA5107-1MH31-0AA0 7-80<br />

3VA5107-1MU31-0AA0 7-80<br />

3VA5110-1BB21-0AA0 7-79<br />

3VA5110-1BB31-0AA0 7-79<br />

3VA5110-1MH31-0AA0 7-80<br />

3VA5110-1MU31-0AA0 7-80<br />

3VA5110-4EC31-0AA0 7-49<br />

3VA5110-4EC41-0AA0 7-50<br />

3VA5110-4ED11-0AA0 7-48<br />

3VA5110-4ED21-0AA0 7-48<br />

3VA5110-4ED31-0AA0 7-49<br />

3VA5110-4ED41-0AA0 7-50<br />

3VA5110-4EF31-0AA0 7-49<br />

3VA5110-4EF41-0AA0 7-50<br />

3VA5110-4GC41-0AA0 7-50<br />

3VA5110-4GD41-0AA0 7-50<br />

3VA5110-4GF41-0AA0 7-50<br />

3VA5110-5EC31-0AA0 7-49<br />

3VA5110-5EC41-0AA0 7-50<br />

3VA5110-5ED11-0AA0 7-48<br />

3VA5110-5ED21-0AA0 7-48<br />

3VA5110-5ED31-0AA0 7-49<br />

3VA5110-5ED41-0AA0 7-50<br />

3VA5110-5EF31-0AA0 7-49<br />

3VA5110-5EF41-0AA0 7-50<br />

3VA5110-5GC41-0AA0 7-50<br />

3VA5110-5GD41-0AA0 7-50<br />

3VA5110-5GF41-0AA0 7-50<br />

3VA5110-6EC31-0AA0 7-49<br />

3VA5110-6EC41-0AA0 7-50<br />

3VA5110-6ED11-0AA0 7-48<br />

3VA5110-6ED21-0AA0 7-48<br />

3VA5110-6ED31-0AA0 7-49<br />

3VA5110-6ED41-0AA0 7-50<br />

3VA5110-6EF31-0AA0 7-49<br />

3VA5110-6EF41-0AA0 7-50<br />

3VA5110-6GC41-0AA0 7-50<br />

3VA5110-6GD41-0AA0 7-50<br />

3VA5110-6GF41-0AA0 7-50<br />

3VA5111-1MH31-0AA0 7-80<br />

3VA5111-1MU31-0AA0 7-80<br />

3VA5111-4EC31-0AA0 7-49<br />

3VA5111-4EC41-0AA0 7-50<br />

3VA5111-4ED11-0AA0 7-48<br />

3VA5111-4ED21-0AA0 7-48<br />

3VA5111-4ED31-0AA0 7-49<br />

3VA5111-4ED41-0AA0 7-50<br />

3VA5111-4GC41-0AA0 7-50<br />

3VA5111-4GD41-0AA0 7-50<br />

3VA5111-5EC31-0AA0 7-49<br />

3VA5111-5EC41-0AA0 7-50<br />

3VA5111-5ED11-0AA0 7-48<br />

3VA5111-5ED21-0AA0 7-48<br />

3VA5111-5ED31-0AA0 7-49<br />

3VA5111-5ED41-0AA0 7-50<br />

3VA5111-5GC41-0AA0 7-50<br />

3VA5111-5GD41-0AA0 7-50<br />

3VA5111-6EC31-0AA0 7-49<br />

3VA5111-6EC41-0AA0 7-50<br />

3VA5111-6ED11-0AA0 7-48<br />

3VA5111-6ED21-0AA0 7-48<br />

3VA5111-6ED31-0AA0 7-49<br />

3VA5111-6ED41-0AA0 7-50<br />

3VA5111-6GC41-0AA0 7-50<br />

3VA5111-6GD41-0AA0 7-50<br />

3VA5112-1MH31-0AA0 7-80<br />

3VA5112-1MU31-0AA0 7-80<br />

3VA5112-4EC31-0AA0 7-49<br />

3VA5112-4EC41-0AA0 7-50<br />

3VA5112-4ED11-0AA0 7-48<br />

3VA5112-4ED21-0AA0 7-48<br />

3VA5112-4ED31-0AA0 7-49<br />

3VA5112-4ED41-0AA0 7-50<br />

3VA5112-4GC41-0AA0 7-50<br />

3VA5112-4GD41-0AA0 7-50<br />

3VA5112-5EC31-0AA0 7-49<br />

3VA5112-5EC41-0AA0 7-50<br />

3VA5112-5ED11-0AA0 7-48<br />

3VA5112-5ED21-0AA0 7-48<br />

3VA5112-5ED31-0AA0 7-49<br />

3VA5112-5ED41-0AA0 7-50<br />

3VA5112-5GC41-0AA0 7-50<br />

3VA5112-5GD41-0AA0 7-50<br />

3VA5112-6EC31-0AA0 7-49<br />

3VA5112-6EC41-0AA0 7-50<br />

3VA5112-6ED11-0AA0 7-48<br />

3VA5112-6ED21-0AA0 7-48<br />

I-2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

3VA5112-6ED31-0AA0 7-49<br />

3VA5112-6ED41-0AA0 7-50<br />

3VA5112-6GC41-0AA0 7-50<br />

3VA5112-6GD41-0AA0 7-50<br />

3VA5120-4EC31-0AA0 7-49<br />

3VA5120-4EC41-0AA0 7-50<br />

3VA5120-4ED11-0AA0 7-48<br />

3VA5120-4ED21-0AA0 7-48<br />

3VA5120-4ED31-0AA0 7-49<br />

3VA5120-4ED41-0AA0 7-50<br />

3VA5120-4EF31-0AA0 7-49<br />

3VA5120-4EF41-0AA0 7-50<br />

3VA5120-5EC31-0AA0 7-49<br />

3VA5120-5EC41-0AA0 7-50<br />

3VA5120-5ED11-0AA0 7-48<br />

3VA5120-5ED21-0AA0 7-48<br />

3VA5120-5ED31-0AA0 7-49<br />

3VA5120-5ED41-0AA0 7-50<br />

3VA5120-5EF31-0AA0 7-49<br />

3VA5120-5EF41-0AA0 7-50<br />

3VA5120-6EC31-0AA0 7-49<br />

3VA5120-6EC41-0AA0 7-50<br />

3VA5120-6ED11-0AA0 7-48<br />

3VA5120-6ED21-0AA0 7-48<br />

3VA5120-6ED31-0AA0 7-49<br />

3VA5120-6ED41-0AA0 7-50<br />

3VA5120-6EF31-0AA0 7-49<br />

3VA5120-6EF41-0AA0 7-50<br />

3VA5125-1MH31-0AA0 7-80<br />

3VA5125-1MU31-0AA0 7-80<br />

3VA5125-4EC31-0AA0 7-49<br />

3VA5125-4EC41-0AA0 7-50<br />

3VA5125-4ED11-0AA0 7-48<br />

3VA5125-4ED21-0AA0 7-48<br />

3VA5125-4ED31-0AA0 7-49<br />

3VA5125-4ED41-0AA0 7-50<br />

3VA5125-5EC31-0AA0 7-49<br />

3VA5125-5EC41-0AA0 7-50<br />

3VA5125-5ED11-0AA0 7-48<br />

3VA5125-5ED21-0AA0 7-48<br />

3VA5125-5ED31-0AA0 7-49<br />

3VA5125-5ED41-0AA0 7-50<br />

3VA5125-6EC31-0AA0 7-49<br />

3VA5125-6EC41-0AA0 7-50<br />

3VA5125-6ED11-0AA0 7-48<br />

3VA5125-6ED21-0AA0 7-48<br />

3VA5125-6ED31-0AA0 7-49<br />

3VA5125-6ED41-0AA0 7-50<br />

3VA5130-1MH31-0AA0 7-80<br />

3VA5130-1MU31-0AA0 7-80<br />

3VA5130-4EC31-0AA0 7-49<br />

3VA5130-4EC41-0AA0 7-50<br />

3VA5130-4ED11-0AA0 7-48<br />

3VA5130-4ED21-0AA0 7-48<br />

3VA5130-4ED31-0AA0 7-49<br />

3VA5130-4ED41-0AA0 7-50<br />

3VA5130-4EF31-0AA0 7-49<br />

3VA5130-4EF41-0AA0 7-50<br />

3VA5130-5EC31-0AA0 7-49<br />

3VA5130-5EC41-0AA0 7-50<br />

3VA5130-5ED11-0AA0 7-48<br />

3VA5130-5ED21-0AA0 7-48<br />

3VA5130-5ED31-0AA0 7-49<br />

3VA5130-5ED41-0AA0 7-50<br />

3VA5130-5EF31-0AA0 7-49<br />

3VA5130-5EF41-0AA0 7-50<br />

3VA5130-6EC31-0AA0 7-49<br />

3VA5130-6EC41-0AA0 7-50<br />

3VA5130-6ED11-0AA0 7-48<br />

3VA5130-6ED21-0AA0 7-48<br />

3VA5130-6ED31-0AA0 7-49<br />

3VA5130-6ED41-0AA0 7-50<br />

3VA5130-6EF31-0AA0 7-49<br />

3VA5130-6EF41-0AA0 7-50<br />

3VA5135-4EC31-0AA0 7-49<br />

3VA5135-4EC41-0AA0 7-50<br />

3VA5135-4ED11-0AA0 7-48<br />

3VA5135-4ED21-0AA0 7-48<br />

3VA5135-4ED31-0AA0 7-49<br />

3VA5135-4ED41-0AA0 7-50<br />

3VA5135-5EC31-0AA0 7-49<br />

3VA5135-5EC41-0AA0 7-50<br />

3VA5135-5ED11-0AA0 7-48<br />

3VA5135-5ED21-0AA0 7-48<br />

3VA5135-5ED31-0AA0 7-49<br />

3VA5135-5ED41-0AA0 7-50<br />

3VA5135-6EC31-0AA0 7-49<br />

3VA5135-6EC41-0AA0 7-50<br />

3VA5135-6ED11-0AA0 7-48<br />

3VA5135-6ED21-0AA0 7-48<br />

3VA5135-6ED31-0AA0 7-49<br />

3VA5135-6ED41-0AA0 7-50<br />

3VA5140-1MH31-0AA0 7-80<br />

3VA5140-1MU31-0AA0 7-80<br />

3VA5140-4EC31-0AA0 7-49<br />

3VA5140-4EC41-0AA0 7-50<br />

3VA5140-4ED11-0AA0 7-48<br />

3VA5140-4ED21-0AA0 7-48<br />

3VA5140-4ED31-0AA0 7-49<br />

3VA5140-4ED41-0AA0 7-50<br />

3VA5140-4EF31-0AA0 7-49<br />

3VA5140-4EF41-0AA0 7-50<br />

3VA5140-5EC31-0AA0 7-49<br />

3VA5140-5EC41-0AA0 7-50<br />

3VA5140-5ED11-0AA0 7-48<br />

3VA5140-5ED21-0AA0 7-48<br />

3VA5140-5ED31-0AA0 7-49<br />

3VA5140-5ED41-0AA0 7-50<br />

3VA5140-5EF31-0AA0 7-49<br />

3VA5140-5EF41-0AA0 7-50<br />

3VA5140-6EC31-0AA0 7-49<br />

3VA5140-6EC41-0AA0 7-50<br />

3VA5140-6ED11-0AA0 7-48<br />

3VA5140-6ED21-0AA0 7-48<br />

3VA5140-6ED31-0AA0 7-49<br />

3VA5140-6ED41-0AA0 7-50<br />

3VA5140-6EF31-0AA0 7-49<br />

3VA5140-6EF41-0AA0 7-50<br />

3VA5145-4EC31-0AA0 7-49<br />

3VA5145-4EC41-0AA0 7-50<br />

3VA5145-4ED11-0AA0 7-48<br />

3VA5145-4ED21-0AA0 7-48<br />

3VA5145-4ED31-0AA0 7-49<br />

3VA5145-4ED41-0AA0 7-50<br />

3VA5145-5EC31-0AA0 7-49<br />

3VA5145-5EC41-0AA0 7-50<br />

3VA5145-5ED11-0AA0 7-48<br />

3VA5145-5ED21-0AA0 7-48<br />

3VA5145-5ED31-0AA0 7-49<br />

3VA5145-5ED41-0AA0 7-50<br />

3VA5145-6EC31-0AA0 7-49<br />

3VA5145-6EC41-0AA0 7-50<br />

3VA5145-6ED11-0AA0 7-48<br />

3VA5145-6ED21-0AA0 7-48<br />

3VA5145-6ED31-0AA0 7-49<br />

3VA5145-6ED41-0AA0 7-50<br />

3VA5150-1MH31-0AA0 7-80<br />

3VA5150-1MU31-0AA0 7-80<br />

3VA5150-4EC31-0AA0 7-49<br />

3VA5150-4EC41-0AA0 7-50<br />

3VA5150-4ED11-0AA0 7-48<br />

3VA5150-4ED21-0AA0 7-48<br />

3VA5150-4ED31-0AA0 7-49<br />

3VA5150-4ED41-0AA0 7-50<br />

3VA5150-4EF31-0AA0 7-49<br />

3VA5150-4EF41-0AA0 7-50<br />

3VA5150-5EC31-0AA0 7-49<br />

3VA5150-5EC41-0AA0 7-50<br />

3VA5150-5ED11-0AA0 7-48<br />

3VA5150-5ED21-0AA0 7-48<br />

3VA5150-5ED31-0AA0 7-49<br />

3VA5150-5ED41-0AA0 7-50<br />

3VA5150-5EF31-0AA0 7-49<br />

3VA5150-5EF41-0AA0 7-50<br />

3VA5150-6EC31-0AA0 7-49<br />

3VA5150-6EC41-0AA0 7-50<br />

3VA5150-6ED11-0AA0 7-48<br />

3VA5150-6ED21-0AA0 7-48<br />

3VA5150-6ED31-0AA0 7-49<br />

3VA5150-6ED41-0AA0 7-50<br />

3VA5150-6EF31-0AA0 7-49<br />

3VA5150-6EF41-0AA0 7-50<br />

3VA5160-4EC31-0AA0 7-49<br />

3VA5160-4EC41-0AA0 7-50<br />

3VA5160-4ED11-0AA0 7-48<br />

3VA5160-4ED21-0AA0 7-48<br />

3VA5160-4ED31-0AA0 7-49<br />

3VA5160-4ED41-0AA0 7-50<br />

3VA5160-4EF31-0AA0 7-49<br />

3VA5160-4EF41-0AA0 7-50<br />

3VA5160-5EC31-0AA0 7-49<br />

3VA5160-5EC41-0AA0 7-50<br />

3VA5160-5ED11-0AA0 7-48<br />

3VA5160-5ED21-0AA0 7-48<br />

3VA5160-5ED31-0AA0 7-49<br />

3VA5160-5ED41-0AA0 7-50<br />

3VA5160-5EF31-0AA0 7-49<br />

3VA5160-5EF41-0AA0 7-50<br />

3VA5160-6EC31-0AA0 7-49<br />

3VA5160-6EC41-0AA0 7-50<br />

3VA5160-6ED11-0AA0 7-48<br />

3VA5160-6ED21-0AA0 7-48<br />

3VA5160-6ED31-0AA0 7-49<br />

3VA5160-6ED41-0AA0 7-50<br />

3VA5160-6EF31-0AA0 7-49<br />

3VA5160-6EF41-0AA0 7-50<br />

3VA5170-1MH31-0AA0 7-80<br />

3VA5170-1MU31-0AA0 7-80<br />

3VA5170-4EC31-0AA0 7-49<br />

3VA5170-4EC41-0AA0 7-50<br />

3VA5170-4ED11-0AA0 7-48<br />

3VA5170-4ED21-0AA0 7-48<br />

3VA5170-4ED31-0AA0 7-49<br />

3VA5170-4ED41-0AA0 7-50<br />

3VA5170-4EF31-0AA0 7-49<br />

3VA5170-4EF41-0AA0 7-50<br />

3VA5170-5EC31-0AA0 7-49<br />

3VA5170-5EC41-0AA0 7-50<br />

3VA5170-5ED11-0AA0 7-48<br />

3VA5170-5ED21-0AA0 7-48<br />

3VA5170-5ED31-0AA0 7-49<br />

3VA5170-5ED41-0AA0 7-50<br />

3VA5170-5EF31-0AA0 7-49<br />

3VA5170-5EF41-0AA0 7-50<br />

3VA5170-6EC31-0AA0 7-49<br />

3VA5170-6EC41-0AA0 7-50<br />

3VA5170-6ED11-0AA0 7-48<br />

3VA5170-6ED21-0AA0 7-48<br />

3VA5170-6ED31-0AA0 7-49<br />

3VA5170-6ED41-0AA0 7-50<br />

3VA5170-6EF31-0AA0 7-49<br />

3VA5170-6EF41-0AA0 7-50<br />

3VA5180-1MH31-0AA0 7-80<br />

3VA5180-1MU31-0AA0 7-80<br />

3VA5180-4EC31-0AA0 7-49<br />

3VA5180-4EC41-0AA0 7-50<br />

3VA5180-4ED11-0AA0 7-48<br />

3VA5180-4ED21-0AA0 7-48<br />

3VA5180-4ED31-0AA0 7-49<br />

3VA5180-4ED41-0AA0 7-50<br />

3VA5180-4EF31-0AA0 7-49<br />

3VA5180-4EF41-0AA0 7-50<br />

3VA5180-5EC31-0AA0 7-49<br />

3VA5180-5EC41-0AA0 7-50<br />

3VA5180-5ED11-0AA0 7-48<br />

3VA5180-5ED21-0AA0 7-48<br />

3VA5180-5ED31-0AA0 7-49<br />

3VA5180-5ED41-0AA0 7-50<br />

3VA5180-5EF31-0AA0 7-49<br />

3VA5180-5EF41-0AA0 7-50<br />

3VA5180-6EC31-0AA0 7-49<br />

3VA5180-6EC41-0AA0 7-50<br />

3VA5180-6ED11-0AA0 7-48<br />

3VA5180-6ED21-0AA0 7-48<br />

3VA5180-6ED31-0AA0 7-49<br />

3VA5180-6ED41-0AA0 7-50<br />

3VA5180-6EF31-0AA0 7-49<br />

3VA5180-6EF41-0AA0 7-50<br />

3VA5181-1MH31-0AA0 7-80<br />

3VA5181-1MU31-0AA0 7-80<br />

3VA5190-1MH31-0AA0 7-80<br />

3VA5190-1MU31-0AA0 7-80<br />

3VA5190-4EC31-0AA0 7-49<br />

3VA5190-4EC41-0AA0 7-50<br />

3VA5190-4ED11-0AA0 7-48<br />

3VA5190-4ED21-0AA0 7-48<br />

3VA5190-4ED31-0AA0 7-49<br />

3VA5190-4ED41-0AA0 7-50<br />

3VA5190-4GC41-0AA0 7-50<br />

3VA5190-4GD41-0AA0 7-50<br />

3VA5190-5EC31-0AA0 7-49<br />

3VA5190-5EC41-0AA0 7-50<br />

3VA5190-5ED11-0AA0 7-48<br />

3VA5190-5ED21-0AA0 7-48<br />

3VA5190-5ED31-0AA0 7-49<br />

3VA5190-5ED41-0AA0 7-50<br />

3VA5190-5GC41-0AA0 7-50<br />

3VA5190-5GD41-0AA0 7-50<br />

3VA5190-6EC31-0AA0 7-49<br />

3VA5190-6EC41-0AA0 7-50<br />

3VA5190-6ED11-0AA0 7-48<br />

3VA5190-6ED21-0AA0 7-48<br />

3VA5190-6ED31-0AA0 7-49<br />

3VA5190-6ED41-0AA0 7-50<br />

3VA5190-6GC41-0AA0 7-50<br />

3VA5190-6GD41-0AA0 7-50<br />

3VA5191-1MH31-0AA0 7-80<br />

3VA5191-1MU31-0AA0 7-80<br />

3VA5195-1MH31-0AA0 7-80<br />

3VA5195-1MU31-0AA0 7-80<br />

3VA5195-4EC31-0AA0 7-49<br />

3VA5195-4EC41-0AA0 7-50<br />

3VA5195-4ED11-0AA0 7-48<br />

3VA5195-4ED21-0AA0 7-48<br />

3VA5195-4ED31-0AA0 7-49<br />

3VA5195-4ED41-0AA0 7-50<br />

3VA5195-4EF31-0AA0 7-49<br />

3VA5195-4EF41-0AA0 7-50<br />

3VA5195-6EC31-0AA0 7-49<br />

3VA5195-5EC41-0AA0 7-50<br />

3VA5195-5ED11-0AA0 7-48<br />

3VA5195-5ED21-0AA0 7-48<br />

3VA5195-5ED31-0AA0 7-49<br />

3VA5195-5ED41-0AA0 7-50<br />

3VA5195-5EF31-0AA0 7-49<br />

3VA5195-5EF41-0AA0 7-50<br />

3VA5195-6EC31-0AA0 7-49<br />

3VA5195-6EC41-0AA0 7-50<br />

3VA5195-6ED11-0AA0 7-48<br />

3VA5195-6ED21-0AA0 7-48<br />

3VA5195-6ED31-0AA0 7-49<br />

3VA5195-6ED41-0AA0 7-50<br />

3VA5195-6EF31-0AA0 7-49<br />

3VA5195-6EF41-0AA0 7-50<br />

3VA5210-1BB31-0AA0 11-63, 7-79<br />

3VA5210-1BB61-0AA0 11-63, 7-79<br />

3VA5210-5EC31-0AA0 11-63, 7-57<br />

3VA5210-5EC41-0AA0 7-58<br />

3VA5210-5EC61-0AA0 11-63, 7-56<br />

3VA5210-5ED31-0AA0 7-57<br />

3VA5210-5ED41-0AA0 7-58<br />

3VA5210-5ED61-0AA0 7-56<br />

3VA5210-5EF31-0AA0 7-57<br />

3VA5210-5EF41-0AA0 7-58<br />

3VA5210-5GC41-0AA0 7-58<br />

3VA5210-5GD41-0AA0 7-58<br />

3VA5210-5GF41-0AA0 7-58<br />

3VA5210-6EC31-0AA0 11-63, 7-57<br />

3VA5210-6EC41-0AA0 7-58<br />

3VA5210-6EC61-0AA0 11-63, 7-56<br />

3VA5210-6ED31-0AA0 7-57<br />

3VA5210-6ED41-0AA0 7-58<br />

3VA5210-6ED61-0AA0 7-56<br />

3VA5210-6EF31-0AA0 7-57<br />

3VA5210-6EF41-0AA0 7-58<br />

3VA5210-6GC41-0AA0 7-58<br />

3VA5210-6GD41-0AA0 7-58<br />

3VA5210-6GF41-0AA0 7-58<br />

3VA5210-7EC31-0AA0 11-63, 7-57<br />

3VA5210-7EC41-0AA0 7-58<br />

3VA5210-7EC61-0AA0 11-63, 7-56<br />

3VA5210-7ED31-0AA0 7-57<br />

3VA5210-7ED41-0AA0 7-58<br />

3VA5210-7ED61-0AA0 7-56<br />

3VA5210-7EF31-0AA0 7-57<br />

3VA5210-7EF41-0AA0 7-58<br />

3VA5210-7GC41-0AA0 7-58<br />

3VA5210-7GD41-0AA0 7-58<br />

3VA5210-7GF41-0AA0 7-58<br />

3VA5211-5EC31-0AA0 11-63, 7-57<br />

3VA5211-5EC41-0AA0 7-58<br />

3VA5211-5EC61-0AA0 11-63, 7-56<br />

3VA5211-5ED31-0AA0 7-57<br />

3VA5211-5ED41-0AA0 7-58<br />

3VA5211-5ED61-0AA0 7-56<br />

3VA5211-5GC41-0AA0 7-58<br />

3VA5211-5GD41-0AA0 7-58<br />

3VA5211-6EC31-0AA0 11-63, 7-57<br />

3VA5211-6EC41-0AA0 7-58<br />

3VA5211-6EC61-0AA0 11-63, 7-56<br />

3VA5211-6ED31-0AA0 7-57<br />

3VA5211-6ED41-0AA0 7-58<br />

3VA5211-6ED61-0AA0 7-56<br />

3VA5211-6GC41-0AA0 7-58<br />

3VA5211-6GD41-0AA0 7-58<br />

3VA5211-7EC31-0AA0 11-63, 7-57<br />

3VA5211-7EC41-0AA0 7-58<br />

3VA5211-7EC61-0AA0 11-63, 7-56<br />

3VA5211-7ED31-0AA0 7-57<br />

3VA5211-7ED41-0AA0 7-58<br />

3VA5211-7ED61-0AA0 7-56<br />

3VA5211-7GC41-0AA0 7-58<br />

3VA5211-7GD41-0AA0 7-58<br />

3VA5212-5EC31-0AA0 11-63, 7-57<br />

3VA5212-5EC41-0AA0 7-58<br />

3VA5212-5EC61-0AA0 11-63, 7-56<br />

3VA5212-5ED31-0AA0 7-57<br />

3VA5212-5ED41-0AA0 7-58<br />

3VA5212-5ED61-0AA0 7-56<br />

3VA5212-5EF31-0AA0 7-57<br />

3VA5212-5EF41-0AA0 7-58<br />

3VA5212-5GC41-0AA0 7-58<br />

3VA5212-5GD41-0AA0 7-58<br />

3VA5212-5GF41-0AA0 7-58<br />

3VA5212-6EC31-0AA0 11-63, 7-57<br />

3VA5212-6EC41-0AA0 7-58<br />

3VA5212-6EC61-0AA0 11-63, 7-56<br />

3VA5212-6ED31-0AA0 7-57<br />

3VA5212-6ED41-0AA0 7-58<br />

3VA5212-6ED61-0AA0 7-56<br />

3VA5212-6EF31-0AA0 7-57<br />

3VA5212-6EF41-0AA0 7-58<br />

3VA5212-6GC41-0AA0 7-58<br />

3VA5212-6GD41-0AA0 7-58<br />

3VA5212-6GF41-0AA0 7-58<br />

3VA5212-7EC31-0AA0 11-63, 7-57<br />

3VA5212-7EC41-0AA0 7-58<br />

3VA5212-7EC61-0AA0 11-63, 7-56<br />

3VA5212-7ED31-0AA0 7-57<br />

3VA5212-7ED41-0AA0 7-58<br />

3VA5212-7ED61-0AA0 7-56<br />

3VA5212-7EF31-0AA0 7-57<br />

3VA5212-7EF41-0AA0 7-58<br />

3VA5212-7GC41-0AA0 7-58<br />

3VA5212-7GD41-0AA0 7-58<br />

3VA5212-7GF41-0AA0 7-58<br />

3VA5215-0BB31-0AA0 11-63, 7-79<br />

3VA5215-0BB61-0AA0 11-63, 7-79<br />

3VA5215-0MH31-0AA0 7-80<br />

3VA5215-0MU31-0AA0 7-80<br />

3VA5215-1BB31-0AA0 11-63, 7-79<br />

3VA5215-1BB61-0AA0 11-63, 7-79<br />

3VA5215-1MH31-0AA0 7-80<br />

3VA5215-1MU31-0AA0 7-80<br />

3VA5215-5EC31-0AA0 11-63, 7-57<br />

3VA5215-5EC41-0AA0 7-58<br />

3VA5215-5EC61-0AA0 11-63, 7-56<br />

3VA5215-5ED31-0AA0 7-57<br />

3VA5215-5ED41-0AA0 7-58<br />

3VA5215-5ED61-0AA0 7-56<br />

3VA5215-5EF31-0AA0 7-57<br />

3VA5215-5EF41-0AA0 7-58<br />

3VA5215-5GC41-0AA0 7-58<br />

3VA5215-5GD41-0AA0 7-58<br />

3VA5215-5GF41-0AA0 7-58<br />

3VA5215-6EC31-0AA0 11-63, 7-57<br />

3VA5215-6EC41-0AA0 7-58<br />

3VA5215-6EC61-0AA0 11-63, 7-56<br />

3VA5215-6ED31-0AA0 7-57<br />

3VA5215-6ED41-0AA0 7-58<br />

3VA5215-6ED61-0AA0 7-56<br />

3VA5215-6EF31-0AA0 7-57<br />

3VA5215-6EF41-0AA0 7-58<br />

3VA5215-6GC41-0AA0 7-58<br />

3VA5215-6GD41-0AA0 7-58<br />

3VA5215-6GF41-0AA0 7-58<br />

3VA5215-7EC31-0AA0 11-63, 7-57<br />

3VA5215-7EC41-0AA0 7-58<br />

3VA5215-7EC61-0AA0 11-63, 7-56<br />

3VA5215-7ED31-0AA0 7-57<br />

3VA5215-7ED41-0AA0 7-58<br />

3VA5215-7ED61-0AA0 7-56<br />

3VA5215-7EF31-0AA0 7-57<br />

3VA5215-7EF41-0AA0 7-58<br />

3VA5215-7GC41-0AA0 7-58<br />

3VA5215-7GD41-0AA0 7-58<br />

3VA5215-7GF41-0AA0 7-58<br />

3VA5217-5EC31-0AA0 11-63, 7-57<br />

3VA5217-5EC41-0AA0 7-58<br />

3VA5217-5EC61-0AA0 11-63, 7-56<br />

3VA5217-5ED31-0AA0 7-57<br />

3VA5217-5ED41-0AA0 7-58<br />

3VA5217-5ED61-0AA0 7-56<br />

3VA5217-5EF31-0AA0 7-57<br />

3VA5217-5EF41-0AA0 7-58<br />

3VA5217-5GC41-0AA0 7-58<br />

3VA5217-5GD41-0AA0 7-58<br />

3VA5217-5GF41-0AA0 7-58<br />

3VA5217-6EC31-0AA0 11-63, 7-57<br />

3VA5217-6EC41-0AA0 7-58<br />

3VA5217-6EC61-0AA0 11-63, 7-56<br />

3VA5217-6ED31-0AA0 7-57<br />

3VA5217-6ED41-0AA0 7-58<br />

3VA5217-6ED61-0AA0 7-56<br />

3VA5217-6EF31-0AA0 7-57<br />

3VA5217-6EF41-0AA0 7-58<br />

3VA5217-6GC41-0AA0 7-58<br />

3VA5217-6GD41-0AA0 7-58<br />

3VA5217-6GF41-0AA0 7-58<br />

3VA5217-7EC31-0AA0 11-63, 7-57<br />

I<br />

PRODUCT<br />

INDEX<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog I-3


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

I<br />

PRODUCT<br />

INDEX<br />

3VA5217-7EC41-0AA0 7-58<br />

3VA5217-7EC61-0AA0 11-63, 7-56<br />

3VA5217-7ED31-0AA0 7-57<br />

3VA5217-7ED41-0AA0 7-58<br />

3VA5217-7ED61-0AA0 7-56<br />

3VA5217-7EF31-0AA0 7-57<br />

3VA5217-7EF41-0AA0 7-58<br />

3VA5217-7GC41-0AA0 7-58<br />

3VA5217-7GD41-0AA0 7-58<br />

3VA5217-7GF41-0AA0 7-58<br />

3VA5220-0MH31-0AA0 7-80<br />

3VA5220-0MU31-0AA0 7-80<br />

3VA5220-1MH31-0AA0 7-80<br />

3VA5220-1MU31-0AA0 7-80<br />

3VA5220-5EC31-0AA0 11-63, 7-57<br />

3VA5220-5EC41-0AA0 7-58<br />

3VA5220-5EC61-0AA0 11-63, 7-56<br />

3VA5220-5ED31-0AA0 7-57<br />

3VA5220-5ED41-0AA0 7-58<br />

3VA5220-5ED61-0AA0 7-56<br />

3VA5220-5EF31-0AA0 7-57<br />

3VA5220-5EF41-0AA0 7-58<br />

3VA5220-5GC41-0AA0 7-58<br />

3VA5220-5GD41-0AA0 7-58<br />

3VA5220-5GF41-0AA0 7-58<br />

3VA5220-6EC31-0AA0 11-63, 7-57<br />

3VA5220-6EC41-0AA0 7-58<br />

3VA5220-6EC61-0AA0 11-63, 7-56<br />

3VA5220-6ED31-0AA0 7-57<br />

3VA5220-6ED41-0AA0 7-58<br />

3VA5220-6ED61-0AA0 7-56<br />

3VA5220-6EF31-0AA0 7-57<br />

3VA5220-6EF41-0AA0 7-58<br />

3VA5220-6GC41-0AA0 7-58<br />

3VA5220-6GD41-0AA0 7-58<br />

3VA5220-6GF41-0AA0 7-58<br />

3VA5220-7EC31-0AA0 11-63, 7-57<br />

3VA5220-7EC41-0AA0 7-58<br />

3VA5220-7EC61-0AA0 11-63, 7-56<br />

3VA5220-7ED31-0AA0 7-57<br />

3VA5220-7ED41-0AA0 7-58<br />

3VA5220-7ED61-0AA0 7-56<br />

3VA5220-7EF31-0AA0 7-57<br />

3VA5220-7EF41-0AA0 7-58<br />

3VA5220-7GC41-0AA0 7-58<br />

3VA5220-7GD41-0AA0 7-58<br />

3VA5220-7GF41-0AA0 7-58<br />

3VA5222-5EC31-0AA0 11-63, 7-57<br />

3VA5222-5EC41-0AA0 7-58<br />

3VA5222-5EC61-0AA0 11-63, 7-56<br />

3VA5222-5ED31-0AA0 7-57<br />

3VA5222-5ED41-0AA0 7-58<br />

3VA5222-5ED61-0AA0 7-56<br />

3VA5222-5GC41-0AA0 7-58<br />

3VA5222-5GD41-0AA0 7-58<br />

3VA5222-6EC31-0AA0 11-63, 7-57<br />

3VA5222-6EC41-0AA0 7-58<br />

3VA5222-6EC61-0AA0 11-63, 7-56<br />

3VA5222-6ED31-0AA0 7-57<br />

3VA5222-6ED41-0AA0 7-58<br />

3VA5222-6ED61-0AA0 7-56<br />

3VA5222-6GC41-0AA0 7-58<br />

3VA5222-6GD41-0AA0 7-58<br />

3VA5222-7EC31-0AA0 11-63, 7-57<br />

3VA5222-7EC41-0AA0 7-58<br />

3VA5222-7EC61-0AA0 11-63, 7-56<br />

3VA5222-7ED31-0AA0 7-57<br />

3VA5222-7ED41-0AA0 7-58<br />

3VA5222-7ED61-0AA0 7-56<br />

3VA5222-7GC41-0AA0 7-58<br />

3VA5222-7GD41-0AA0 7-58<br />

3VA5225-0BB31-0AA0 11-63, 7-79<br />

3VA5225-0BB61-0AA0 11-63, 7-79<br />

3VA5225-0MH31-0AA0 7-80<br />

3VA5225-0MU31-0AA0 7-80<br />

3VA5225-1BB31-0AA0 11-63, 7-79<br />

3VA5225-1BB61-0AA0 11-63, 7-79<br />

3VA5225-1MH31-0AA0 7-80<br />

3VA5225-1MU31-0AA0 7-80<br />

3VA5225-5EC31-0AA0 11-63, 7-57<br />

3VA5225-5EC41-0AA0 7-58<br />

3VA5225-5EC61-0AA0 11-63, 7-56<br />

3VA5225-5ED31-0AA0 7-57<br />

3VA5225-5ED41-0AA0 7-58<br />

3VA5225-5ED61-0AA0 7-56<br />

3VA5225-5EF31-0AA0 7-57<br />

3VA5225-5EF41-0AA0 7-58<br />

3VA5225-5GC41-0AA0 7-58<br />

3VA5225-5GD41-0AA0 7-58<br />

3VA5225-5GF41-0AA0 7-58<br />

3VA5225-6EC31-0AA0 11-63, 7-57<br />

3VA5225-6EC41-0AA0 7-58<br />

3VA5225-6EC61-0AA0 11-63, 7-56<br />

3VA5225-6ED31-0AA0 7-57<br />

3VA5225-6ED41-0AA0 7-58<br />

3VA5225-6ED61-0AA0 7-56<br />

3VA5225-6EF31-0AA0 7-57<br />

3VA5225-6EF41-0AA0 7-58<br />

3VA5225-6GC41-0AA0 7-58<br />

3VA5225-6GD41-0AA0 7-58<br />

3VA5225-6GF41-0AA0 7-58<br />

3VA5225-7EC31-0AA0 11-63, 7-57<br />

3VA5225-7EC41-0AA0 7-58<br />

3VA5225-7EC61-0AA0 11-63, 7-56<br />

3VA5225-7ED31-0AA0 7-57<br />

3VA5225-7ED41-0AA0 7-58<br />

3VA5225-7ED61-0AA0 7-56<br />

3VA5225-7EF31-0AA0 7-57<br />

3VA5225-7EF41-0AA0 7-58<br />

3VA5225-7GC41-0AA0 7-58<br />

3VA5225-7GD41-0AA0 7-58<br />

3VA5225-7GF41-0AA0 7-58<br />

3VA5240-5ED31-0AA0 7-57<br />

3VA5240-5ED41-0AA0 7-58<br />

3VA5240-5ED61-0AA0 7-56<br />

3VA5240-6ED31-0AA0 7-57<br />

3VA5240-6ED41-0AA0 7-58<br />

3VA5240-6ED61-0AA0 7-56<br />

3VA5240-7ED31-0AA0 7-57<br />

3VA5240-7ED41-0AA0 7-58<br />

3VA5240-7ED61-0AA0 7-56<br />

3VA5245-5ED31-0AA0 7-57<br />

3VA5245-5ED41-0AA0 7-58<br />

3VA5245-5ED61-0AA0 7-56<br />

3VA5245-6ED31-0AA0 7-57<br />

3VA5245-6ED41-0AA0 7-58<br />

3VA5245-6ED61-0AA0 7-56<br />

3VA5245-7ED31-0AA0 7-57<br />

3VA5245-7ED41-0AA0 7-58<br />

3VA5245-7ED61-0AA0 7-56<br />

3VA5250-5ED31-0AA0 7-57<br />

3VA5250-5ED41-0AA0 7-58<br />

3VA5250-5ED61-0AA0 7-56<br />

3VA5250-6ED31-0AA0 7-57<br />

3VA5250-6ED41-0AA0 7-58<br />

3VA5250-6ED61-0AA0 7-56<br />

3VA5250-7ED31-0AA0 7-57<br />

3VA5250-7ED41-0AA0 7-58<br />

3VA5250-7ED61-0AA0 7-56<br />

3VA5260-5ED31-0AA0 7-57<br />

3VA5260-5ED41-0AA0 7-58<br />

3VA5260-5ED61-0AA0 7-56<br />

3VA5260-6ED31-0AA0 7-57<br />

3VA5260-6ED41-0AA0 7-58<br />

3VA5260-6ED61-0AA0 7-56<br />

3VA5260-7ED31-0AA0 7-57<br />

3VA5260-7ED41-0AA0 7-58<br />

3VA5260-7ED61-0AA0 7-56<br />

3VA5270-5EC31-0AA0 7-57<br />

3VA5270-5EC41-0AA0 7-58<br />

3VA5270-5EC61-0AA0 7-56<br />

3VA5270-5ED31-0AA0 7-57<br />

3VA5270-5ED41-0AA0 7-58<br />

3VA5270-5ED61-0AA0 7-56<br />

3VA5270-5EF31-0AA0 7-57<br />

3VA5270-5EF41-0AA0 7-58<br />

3VA5270-6EC31-0AA0 7-57<br />

3VA5270-6EC41-0AA0 7-58<br />

3VA5270-6EC61-0AA0 7-56<br />

3VA5270-6ED31-0AA0 7-57<br />

3VA5270-6ED41-0AA0 7-58<br />

3VA5270-6ED61-0AA0 7-56<br />

3VA5270-6EF31-0AA0 7-57<br />

3VA5270-6EF41-0AA0 7-58<br />

3VA5270-7EC31-0AA0 7-57<br />

3VA5270-7EC41-0AA0 7-58<br />

3VA5270-7EC61-0AA0 7-56<br />

3VA5270-7ED31-0AA0 7-57<br />

3VA5270-7ED41-0AA0 7-58<br />

3VA5270-7ED61-0AA0 7-56<br />

3VA5270-7EF31-0AA0 7-57<br />

3VA5270-7EF41-0AA0 7-58<br />

3VA5280-5EC31-0AA0 7-57<br />

3VA5280-5EC41-0AA0 7-58<br />

3VA5280-5EC61-0AA0 7-56<br />

3VA5280-5ED31-0AA0 7-57<br />

3VA5280-5ED41-0AA0 7-58<br />

3VA5280-5ED61-0AA0 7-56<br />

3VA5280-5EF31-0AA0 7-57<br />

3VA5280-5EF41-0AA0 7-58<br />

3VA5280-6EC31-0AA0 7-57<br />

3VA5280-6EC41-0AA0 7-58<br />

3VA5280-6EC61-0AA0 7-56<br />

3VA5280-6ED31-0AA0 7-57<br />

3VA5280-6ED41-0AA0 7-58<br />

3VA5280-6ED61-0AA0 7-56<br />

3VA5280-6EF31-0AA0 7-57<br />

3VA5280-6EF41-0AA0 7-58<br />

3VA5280-7EC31-0AA0 7-57<br />

3VA5280-7EC41-0AA0 7-58<br />

3VA5280-7EC61-0AA0 7-56<br />

3VA5280-7ED31-0AA0 7-57<br />

3VA5280-7ED41-0AA0 7-58<br />

3VA5280-7ED61-0AA0 7-56<br />

3VA5280-7EF31-0AA0 7-57<br />

3VA5280-7EF41-0AA0 7-58<br />

3VA5290-5EC31-0AA0 7-57<br />

3VA5290-5EC41-0AA0 7-58<br />

3VA5290-5EC61-0AA0 7-56<br />

3VA5290-5ED31-0AA0 7-57<br />

3VA5290-5ED41-0AA0 7-58<br />

3VA5290-5ED61-0AA0 7-56<br />

3VA5290-5GC41-0AA0 7-58<br />

3VA5290-5GD41-0AA0 7-58<br />

3VA5290-6EC31-0AA0 7-57<br />

3VA5290-6EC41-0AA0 7-58<br />

3VA5290-6EC61-0AA0 7-56<br />

3VA5290-6ED31-0AA0 7-57<br />

3VA5290-6ED41-0AA0 7-58<br />

3VA5290-6ED61-0AA0 7-56<br />

3VA5290-6GC41-0AA0 7-58<br />

3VA5290-6GD41-0AA0 7-58<br />

3VA5290-7EC31-0AA0 7-57<br />

3VA5290-7EC41-0AA0 7-58<br />

3VA5290-7EC61-0AA0 7-56<br />

3VA5290-7ED31-0AA0 7-57<br />

3VA5290-7ED41-0AA0 7-58<br />

3VA5290-7ED61-0AA0 7-56<br />

3VA5290-7GC41-0AA0 7-58<br />

3VA5290-7GD41-0AA0 7-58<br />

3VA5320-5EC31-0AA0 11-66, 7-64<br />

3VA5320-5EC41-0AA0 7-65<br />

3VA5320-5EC61-0AA0 11-66, 7-64<br />

3VA5320-5EF31-0AA0 7-64<br />

3VA5320-5EF41-0AA0 7-65<br />

3VA5320-5GC41-0AA0 7-65<br />

3VA5320-5GF41-0AA0 7-65<br />

3VA5320-6EC31-0AA0 11-66, 7-64<br />

3VA5320-6EC41-0AA0 7-65<br />

3VA5320-6EC61-0AA0 11-66, 7-64<br />

3VA5320-6EF31-0AA0 7-64<br />

3VA5320-6EF41-0AA0 7-65<br />

3VA5320-6GC41-0AA0 7-65<br />

3VA5320-6GF41-0AA0 7-65<br />

3VA5320-7EC31-0AA0 11-66, 7-64<br />

3VA5320-7EC41-0AA0 7-65<br />

3VA5320-7EC61-0AA0 11-66, 7-64<br />

3VA5320-7EF31-0AA0 7-64<br />

3VA5320-7EF41-0AA0 7-65<br />

3VA5320-7GC41-0AA0 7-65<br />

3VA5320-7GF41-0AA0 7-65<br />

3VA5322-5EC31-0AA0 11-66, 7-64<br />

3VA5322-5EC41-0AA0 7-65<br />

3VA5322-5EC61-0AA0 11-66, 7-64<br />

3VA5322-5EF31-0AA0 7-64<br />

3VA5322-5EF41-0AA0 7-65<br />

3VA5322-5GC41-0AA0 7-65<br />

3VA5322-5GF41-0AA0 7-65<br />

3VA5322-6EC31-0AA0 11-66, 7-64<br />

3VA5322-6EC41-0AA0 7-65<br />

3VA5322-6EC61-0AA0 11-66, 7-64<br />

3VA5322-6EF31-0AA0 7-64<br />

3VA5322-6EF41-0AA0 7-65<br />

3VA5322-6GC41-0AA0 7-65<br />

3VA5322-6GF41-0AA0 7-65<br />

3VA5322-7EC31-0AA0 11-66, 7-64<br />

3VA5322-7EC41-0AA0 7-65<br />

3VA5322-7EC61-0AA0 11-66, 7-64<br />

3VA5322-7EF31-0AA0 7-64<br />

3VA5322-7EF41-0AA0 7-65<br />

3VA5322-7GC41-0AA0 7-65<br />

3VA5322-7GF41-0AA0 7-65<br />

3VA5325-0MH31-0AA0 7-80<br />

3VA5325-0MU31-0AA0 7-80<br />

3VA5325-1MH31-0AA0 7-80<br />

3VA5325-1MU31-0AA0 7-80<br />

3VA5325-5EC31-0AA0 11-66, 7-64<br />

3VA5325-5EC41-0AA0 7-65<br />

3VA5325-5EC61-0AA0 11-66, 7-64<br />

3VA5325-5EF31-0AA0 7-64<br />

3VA5325-5EF41-0AA0 7-65<br />

3VA5325-5GC41-0AA0 7-65<br />

3VA5325-5GF41-0AA0 7-65<br />

3VA5325-6EC31-0AA0 11-66, 7-64<br />

3VA5325-6EC41-0AA0 7-65<br />

3VA5325-6EC61-0AA0 11-66, 7-64<br />

3VA5325-6EF31-0AA0 7-64<br />

3VA5325-6EF41-0AA0 7-65<br />

3VA5325-6GC41-0AA0 7-65<br />

3VA5325-6GF41-0AA0 7-65<br />

3VA5325-7EC31-0AA0 11-66, 7-64<br />

3VA5325-7EC41-0AA0 7-65<br />

3VA5325-7EC61-0AA0 11-66, 7-64<br />

3VA5325-7EF31-0AA0 7-64<br />

3VA5325-7EF41-0AA0 7-65<br />

3VA5325-7GC41-0AA0 7-65<br />

3VA5325-7GF41-0AA0 7-65<br />

3VA5330-5EC31-0AA0 11-66, 7-64<br />

3VA5330-5EC41-0AA0 7-65<br />

3VA5330-5EC61-0AA0 11-66, 7-64<br />

3VA5330-5EF31-0AA0 7-64<br />

3VA5330-5EF41-0AA0 7-65<br />

3VA5330-5GC41-0AA0 7-65<br />

3VA5330-5GF41-0AA0 7-65<br />

3VA5330-6EC31-0AA0 11-66, 7-64<br />

3VA5330-6EC41-0AA0 7-65<br />

3VA5330-6EC61-0AA0 11-66, 7-64<br />

3VA5330-6EF31-0AA0 7-64<br />

3VA5330-6EF41-0AA0 7-65<br />

3VA5330-6GC41-0AA0 7-65<br />

3VA5330-6GF41-0AA0 7-65<br />

3VA5330-7EC31-0AA0 11-66, 7-64<br />

3VA5330-7EC41-0AA0 7-65<br />

3VA5330-7EC61-0AA0 11-66, 7-64<br />

3VA5330-7EF31-0AA0 7-64<br />

3VA5330-7EF41-0AA0 7-65<br />

3VA5330-7GC41-0AA0 7-65<br />

3VA5330-7GF41-0AA0 7-65<br />

3VA5335-5EC31-0AA0 11-66, 7-64<br />

3VA5335-5EC41-0AA0 7-65<br />

3VA5335-5EC61-0AA0 11-66, 7-64<br />

3VA5335-5EF31-0AA0 7-64<br />

3VA5335-5EF41-0AA0 7-65<br />

3VA5335-5GC41-0AA0 7-65<br />

3VA5335-5GF41-0AA0 7-65<br />

3VA5335-6EC31-0AA0 11-66, 7-64<br />

3VA5335-6EC41-0AA0 7-65<br />

3VA5335-6EC61-0AA0 11-66, 7-64<br />

3VA5335-6EF31-0AA0 7-64<br />

3VA5335-6EF41-0AA0 7-65<br />

3VA5335-6GC41-0AA0 7-65<br />

3VA5335-6GF41-0AA0 7-65<br />

3VA5335-7EC31-0AA0 11-66, 7-64<br />

3VA5335-7EC41-0AA0 7-65<br />

3VA5335-7EC61-0AA0 11-66, 7-64<br />

3VA5335-7EF31-0AA0 7-64<br />

3VA5335-7EF41-0AA0 7-65<br />

3VA5335-7GC41-0AA0 7-65<br />

3VA5335-7GF41-0AA0 7-65<br />

3VA5340-0BB31-0AA0 7-79<br />

3VA5340-0BB61-0AA0 7-79<br />

3VA5340-1BB31-0AA0 7-79<br />

3VA5340-1BB61-0AA0 7-79<br />

3VA5340-5EC31-0AA0 11-66, 7-64<br />

3VA5340-5EC41-0AA0 7-65<br />

3VA5340-5EC61-0AA0 11-66, 7-64<br />

3VA5340-5EF31-0AA0 7-64<br />

3VA5340-5EF41-0AA0 7-65<br />

3VA5340-5GC41-0AA0 7-65<br />

3VA5340-5GF41-0AA0 7-65<br />

3VA5340-6EC31-0AA0 11-66, 7-64<br />

3VA5340-6EC41-0AA0 7-65<br />

3VA5340-6EC61-0AA0 11-66, 7-64<br />

3VA5340-6EF31-0AA0 7-64<br />

3VA5340-6EF41-0AA0 7-65<br />

3VA5340-6GC41-0AA0 7-65<br />

3VA5340-6GF41-0AA0 7-65<br />

3VA5340-7EC31-0AA0 11-66, 7-64<br />

3VA5340-7EC41-0AA0 7-65<br />

3VA5340-7EC61-0AA0 11-66, 7-64<br />

3VA5340-7EF31-0AA0 7-64<br />

3VA5340-7EF41-0AA0 7-65<br />

3VA5340-7GC41-0AA0 7-65<br />

3VA5340-7GF41-0AA0 7-65<br />

3VA5440-0MH31-0AA0 7-80<br />

3VA5440-0MU31-0AA0 7-80<br />

3VA5440-1MH31-0AA0 7-80<br />

3VA5440-1MU31-0AA0 7-80<br />

3VA5445-5EC31-0AA0 11-67, 7-69<br />

3VA5445-5EC41-0AA0 7-69<br />

3VA5445-5EC61-0AA0 11-67, 7-69<br />

3VA5445-5EF31-0AA0 7-69<br />

3VA5445-5EF41-0AA0 7-69<br />

3VA5445-5GC41-0AA0 7-69<br />

3VA5445-5GF41-0AA0 7-69<br />

3VA5445-6EC31-0AA0 11-67, 7-69<br />

3VA5445-6EC41-0AA0 7-69<br />

3VA5445-6EC61-0AA0 11-67, 7-69<br />

3VA5445-6EF31-0AA0 7-69<br />

3VA5445-6EF41-0AA0 7-69<br />

3VA5445-6GC41-0AA0 7-69<br />

3VA5445-6GF41-0AA0 7-69<br />

3VA5445-7EC31-0AA0 11-67, 7-69<br />

3VA5445-7EC41-0AA0 7-69<br />

3VA5445-7EC61-0AA0 11-67, 7-69<br />

3VA5445-7EF31-0AA0 7-69<br />

3VA5445-7EF41-0AA0 7-69<br />

3VA5445-7GC41-0AA0 7-69<br />

3VA5445-7GF41-0AA0 7-69<br />

3VA5450-0MH31-0AA0 7-80<br />

3VA5450-0MU31-0AA0 7-80<br />

3VA5450-1MH31-0AA0 7-80<br />

3VA5450-1MU31-0AA0 7-80<br />

3VA5450-5EC31-0AA0 11-67, 7-69<br />

3VA5450-5EC41-0AA0 7-69<br />

3VA5450-5EC61-0AA0 11-67, 7-69<br />

3VA5450-5EF31-0AA0 7-69<br />

3VA5450-5EF41-0AA0 7-69<br />

3VA5450-5GC41-0AA0 7-69<br />

3VA5450-5GF41-0AA0 7-69<br />

3VA5450-6EC31-0AA0 11-67, 7-69<br />

3VA5450-6EC41-0AA0 7-69<br />

3VA5450-6EC61-0AA0 11-67, 7-69<br />

3VA5450-6EF31-0AA0 7-69<br />

3VA5450-6EF41-0AA0 7-69<br />

3VA5450-6GC41-0AA0 7-69<br />

3VA5450-6GF41-0AA0 7-69<br />

3VA5450-7EC31-0AA0 11-67, 7-69<br />

3VA5450-7EC41-0AA0 7-69<br />

3VA5450-7EC61-0AA0 11-67, 7-69<br />

3VA5450-7EF31-0AA0 7-69<br />

3VA5450-7EF41-0AA0 7-69<br />

3VA5450-7GC41-0AA0 7-69<br />

3VA5450-7GF41-0AA0 7-69<br />

3VA5460-0BB31-0AA0 7-79<br />

3VA5460-0BB61-0AA0 7-79<br />

3VA5460-0MH31-0AA0 7-80<br />

3VA5460-0MU31-0AA0 7-80<br />

3VA5460-1BB31-0AA0 7-79<br />

3VA5460-1BB61-0AA0 7-79<br />

3VA5460-1MH31-0AA0 7-80<br />

3VA5460-1MU31-0AA0 7-80<br />

3VA5460-5EC31-0AA0 11-67, 7-69<br />

3VA5460-5EC41-0AA0 7-69<br />

3VA5460-5EC61-0AA0 11-67, 7-69<br />

3VA5460-5EF31-0AA0 7-69<br />

3VA5460-5EF41-0AA0 7-69<br />

3VA5460-5GC41-0AA0 7-69<br />

3VA5460-5GF41-0AA0 7-69<br />

3VA5460-6EC31-0AA0 11-67, 7-69<br />

3VA5460-6EC41-0AA0 7-69<br />

3VA5460-6EC61-0AA0 11-67, 7-69<br />

3VA5460-6EF31-0AA0 7-69<br />

3VA5460-6EF41-0AA0 7-69<br />

3VA5460-6GC41-0AA0 7-69<br />

3VA5460-6GF41-0AA0 7-69<br />

3VA5460-7EC31-0AA0 11-67, 7-69<br />

3VA5460-7EC41-0AA0 7-69<br />

3VA5460-7EC61-0AA0 11-67, 7-69<br />

3VA5460-7EF31-0AA0 7-69<br />

3VA5460-7EF41-0AA0 7-69<br />

3VA5460-7GC41-0AA0 7-69<br />

3VA5460-7GF41-0AA0 7-69<br />

3VA5560-0MH31-0AA0 7-80<br />

3VA5560-1MH31-0AA0 7-80<br />

3VA5560-5EC32-0AA0 7-73<br />

3VA5560-5EC42-0AA0 7-73<br />

3VA5560-5EC62-0AA0 7-73<br />

3VA5560-5GC42-0AA0 7-73<br />

3VA5560-6EC32-0AA0 7-73<br />

3VA5560-6EC42-0AA0 7-73<br />

3VA5560-6EC62-0AA0 7-73<br />

3VA5560-6GC42-0AA0 7-73<br />

3VA5560-7EC32-0AA0 7-73<br />

3VA5560-7EC42-0AA0 7-73<br />

3VA5560-7EC62-0AA0 7-73<br />

3VA5560-7GC42-0AA0 7-73<br />

3VA5570-5EC32-0AA0 7-73<br />

3VA5570-5EC42-0AA0 7-73<br />

3VA5570-5EC62-0AA0 7-73<br />

I-4<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

3VA5570-5GC42-0AA0 7-73<br />

3VA5570-6EC32-0AA0 7-73<br />

3VA5570-6EC42-0AA0 7-73<br />

3VA5570-6EC62-0AA0 7-73<br />

3VA5570-6GC42-0AA0 7-73<br />

3VA5570-7EC32-0AA0 7-73<br />

3VA5570-7EC42-0AA0 7-73<br />

3VA5570-7EC62-0AA0 7-73<br />

3VA5570-7GC42-0AA0 7-73<br />

3VA5580-0BB31-0AA0 7-79<br />

3VA5580-0BB61-0AA0 7-79<br />

3VA5580-1BB31-0AA0 7-79<br />

3VA5580-1BB61-0AA0 7-79<br />

3VA5580-5EC32-0AA0 7-73<br />

3VA5580-5EC42-0AA0 7-73<br />

3VA5580-5EC62-0AA0 7-73<br />

3VA5580-5GC42-0AA0 7-73<br />

3VA5580-6EC32-0AA0 7-73<br />

3VA5580-6EC42-0AA0 7-73<br />

3VA5580-6EC62-0AA0 7-73<br />

3VA5580-6GC42-0AA0 7-73<br />

3VA5580-7EC32-0AA0 7-73<br />

3VA5580-7EC42-0AA0 7-73<br />

3VA5580-7EC62-0AA0 7-73<br />

3VA5580-7GC42-0AA0 7-73<br />

3VA6004X 6-12<br />

3VA6004X316 6-12<br />

3VA6110-0HL31-0AA0 7-52<br />

3VA6110-0HL41-0AA0 7-53<br />

3VA6110-0HM31-0AA0 7-52<br />

3VA6110-0HM41-0AA0 7-53<br />

3VA6110-0HN31-0AA0 7-52<br />

3VA6110-0HN41-0AA0 7-53<br />

3VA6110-0KQ31-0AA0 7-52<br />

3VA6110-0KQ41-0AA0 7-53<br />

3VA6110-0KT31-0AA0 7-52<br />

3VA6110-0KT41-0AA0 7-53<br />

3VA6110-1MS31-0AA0 7-80<br />

3VA6110-5HL31-0AA0 7-52<br />

3VA6110-5HL41-0AA0 7-53<br />

3VA6110-5HM31-0AA0 7-52<br />

3VA6110-5HM41-0AA0 7-53<br />

3VA6110-5HN31-0AA0 11-57, 7-52<br />

3VA6110-5HN31-2AA0 11-58<br />

3VA6110-5HN41-0AA0 7-53<br />

3VA6110-5JP31-0AA0 7-52<br />

3VA6110-5JP41-0AA0 7-53<br />

3VA6110-5JQ31-0AA0 7-52<br />

3VA6110-5JQ41-0AA0 7-53<br />

3VA6110-5JT31-0AA0 7-52<br />

3VA6110-5JT41-0AA0 7-53<br />

3VA6110-5KL31-0AA0 7-52<br />

3VA6110-5KL41-0AA0 7-53<br />

3VA6110-5KM31-0AA0 7-52<br />

3VA6110-5KM41-0AA0 7-53<br />

3VA6110-5KP31-0AA0 7-52<br />

3VA6110-5KP41-0AA0 7-53<br />

3VA6110-5KQ31-0AA0 7-52<br />

3VA6110-5KQ41-0AA0 7-53<br />

3VA6110-5KT31-0AA0 7-52<br />

3VA6110-5KT41-0AA0 7-53<br />

3VA6110-6HL31-0AA0 7-52<br />

3VA6110-6HL41-0AA0 7-53<br />

3VA6110-6HM31-0AA0 7-52<br />

3VA6110-6HM41-0AA0 7-53<br />

3VA6110-6HN31-0AA0 11-57, 7-52<br />

3VA6110-6HN31-2AA0 11-58<br />

3VA6110-6HN41-0AA0 7-53<br />

3VA6110-6JP31-0AA0 7-52<br />

3VA6110-6JP41-0AA0 7-53<br />

3VA6110-6JQ31-0AA0 7-52<br />

3VA6110-6JQ41-0AA0 7-53<br />

3VA6110-6JT31-0AA0 7-52<br />

3VA6110-6JT41-0AA0 7-53<br />

3VA6110-6KL31-0AA0 7-52<br />

3VA6110-6KL41-0AA0 7-53<br />

3VA6110-6KM31-0AA0 7-52<br />

3VA6110-6KM41-0AA0 7-53<br />

3VA6110-6KP31-0AA0 7-52<br />

3VA6110-6KP41-0AA0 7-53<br />

3VA6110-6KQ31-0AA0 7-52<br />

3VA6110-6KQ41-0AA0 7-53<br />

3VA6110-6KT31-0AA0 7-52<br />

3VA6110-6KT41-0AA0 7-53<br />

3VA6110-7HL31-0AA0 7-52<br />

3VA6110-7HL41-0AA0 7-53<br />

3VA6110-7HM31-0AA0 7-52<br />

3VA6110-7HM41-0AA0 7-53<br />

3VA6110-7HN31-0AA0 11-57, 7-52<br />

3VA6110-7HN31-2AA0 11-58<br />

3VA6110-7HN41-0AA0 7-53<br />

3VA6110-7JP31-0AA0 7-52<br />

3VA6110-7JP41-0AA0 7-53<br />

3VA6110-7JQ31-0AA0 7-52<br />

3VA6110-7JQ41-0AA0 7-53<br />

3VA6110-7JT31-0AA0 7-52<br />

3VA6110-7JT41-0AA0 7-53<br />

3VA6110-7KL31-0AA0 7-52<br />

3VA6110-7KL41-0AA0 7-53<br />

3VA6110-7KM31-0AA0 7-52<br />

3VA6110-7KM41-0AA0 7-53<br />

3VA6110-7KP31-0AA0 7-52<br />

3VA6110-7KP41-0AA0 7-53<br />

3VA6110-7KQ31-0AA0 7-52<br />

3VA6110-7KQ41-0AA0 7-53<br />

3VA6110-7KT31-0AA0 7-52<br />

3VA6110-7KT41-0AA0 7-53<br />

3VA6110-8HL31-0AA0 7-52<br />

3VA6110-8HL41-0AA0 7-53<br />

3VA6110-8HM31-0AA0 7-52<br />

3VA6110-8HM41-0AA0 7-53<br />

3VA6110-8HN31-0AA0 11-57, 7-52<br />

3VA6110-8HN31-2AA0 11-58<br />

3VA6110-8HN41-0AA0 7-53<br />

3VA6110-8JP31-0AA0 7-52<br />

3VA6110-8JP41-0AA0 7-53<br />

3VA6110-8JQ31-0AA0 7-52<br />

3VA6110-8JQ41-0AA0 7-53<br />

3VA6110-8JT31-0AA0 7-52<br />

3VA6110-8JT41-0AA0 7-53<br />

3VA6110-8KL31-0AA0 7-52<br />

3VA6110-8KL41-0AA0 7-53<br />

3VA6110-8KM31-0AA0 7-52<br />

3VA6110-8KM41-0AA0 7-53<br />

3VA6110-8KP31-0AA0 7-52<br />

3VA6110-8KP41-0AA0 7-53<br />

3VA6110-8KQ31-0AA0 7-52<br />

3VA6110-8KQ41-0AA0 7-53<br />

3VA6110-8KT31-0AA0 7-52<br />

3VA6110-8KT41-0AA0 7-53<br />

3VA6115-0HL31-0AA0 7-52<br />

3VA6115-0HL41-0AA0 7-53<br />

3VA6115-0HM31-0AA0 7-52<br />

3VA6115-0HM41-0AA0 7-53<br />

3VA6115-0HN31-0AA0 7-52<br />

3VA6115-0HN41-0AA0 7-53<br />

3VA6115-0KQ31-0AA0 7-52<br />

3VA6115-0KQ41-0AA0 7-53<br />

3VA6115-0KT31-0AA0 7-52<br />

3VA6115-0KT41-0AA0 7-53<br />

3VA6115-5HL31-0AA0 7-52<br />

3VA6115-5HL41-0AA0 7-53<br />

3VA6115-5HM31-0AA0 7-52<br />

3VA6115-5HM41-0AA0 7-53<br />

3VA6115-5HN31-0AA0 11-57, 7-52<br />

3VA6115-5HN31-2AA0 11-58<br />

3VA6115-5HN41-0AA0 7-53<br />

3VA6115-5JP31-0AA0 7-52<br />

3VA6115-5JP41-0AA0 7-53<br />

3VA6115-5JQ31-0AA0 7-52<br />

3VA6115-5JQ41-0AA0 7-53<br />

3VA6115-5JT31-0AA0 7-52<br />

3VA6115-5JT41-0AA0 7-53<br />

3VA6115-5KL31-0AA0 7-52<br />

3VA6115-5KL41-0AA0 7-53<br />

3VA6115-5KM31-0AA0 7-52<br />

3VA6115-5KM41-0AA0 7-53<br />

3VA6115-5KP31-0AA0 7-52<br />

3VA6115-5KP41-0AA0 7-53<br />

3VA6115-5KQ31-0AA0 7-52<br />

3VA6115-5KQ41-0AA0 7-53<br />

3VA6115-5KT31-0AA0 7-52<br />

3VA6115-5KT41-0AA0 7-53<br />

3VA6115-6HL31-0AA0 7-52<br />

3VA6115-6HL41-0AA0 7-53<br />

3VA6115-6HM31-0AA0 7-52<br />

3VA6115-6HM41-0AA0 7-53<br />

3VA6115-6HN31-0AA0 11-57, 7-52<br />

3VA6115-6HN31-2AA0 11-58<br />

3VA6115-6HN41-0AA0 7-53<br />

3VA6115-6JP31-0AA0 7-52<br />

3VA6115-6JP41-0AA0 7-53<br />

3VA6115-6JQ31-0AA0 7-52<br />

3VA6115-6JQ41-0AA0 7-53<br />

3VA6115-6JT31-0AA0 7-52<br />

3VA6115-6JT41-0AA0 7-53<br />

3VA6115-6KL31-0AA0 7-52<br />

3VA6115-6KL41-0AA0 7-53<br />

3VA6115-6KM31-0AA0 7-52<br />

3VA6115-6KM41-0AA0 7-53<br />

3VA6115-6KP31-0AA0 7-52<br />

3VA6115-6KP41-0AA0 7-53<br />

3VA6115-6KQ31-0AA0 7-52<br />

3VA6115-6KQ41-0AA0 7-53<br />

3VA6115-6KT31-0AA0 7-52<br />

3VA6115-6KT41-0AA0 7-53<br />

3VA6115-7HL31-0AA0 7-52<br />

3VA6115-7HL41-0AA0 7-53<br />

3VA6115-7HM31-0AA0 7-52<br />

3VA6115-7HM41-0AA0 7-53<br />

3VA6115-7HN31-0AA0 11-57, 7-52<br />

3VA6115-7HN31-2AA0 11-58<br />

3VA6115-7HN41-0AA0 7-53<br />

3VA6115-7JP31-0AA0 7-52<br />

3VA6115-7JP41-0AA0 7-53<br />

3VA6115-7JQ31-0AA0 7-52<br />

3VA6115-7JQ41-0AA0 7-53<br />

3VA6115-7JT31-0AA0 7-52<br />

3VA6115-7JT41-0AA0 7-53<br />

3VA6115-7KL31-0AA0 7-52<br />

3VA6115-7KL41-0AA0 7-53<br />

3VA6115-7KM31-0AA0 7-52<br />

3VA6115-7KM41-0AA0 7-53<br />

3VA6115-7KP31-0AA0 7-52<br />

3VA6115-7KP41-0AA0 7-53<br />

3VA6115-7KQ31-0AA0 7-52<br />

3VA6115-7KQ41-0AA0 7-53<br />

3VA6115-7KT31-0AA0 7-52<br />

3VA6115-7KT41-0AA0 7-53<br />

3VA6115-8HL31-0AA0 7-52<br />

3VA6115-8HL41-0AA0 7-53<br />

3VA6115-8HM31-0AA0 7-52<br />

3VA6115-8HM41-0AA0 7-53<br />

3VA6115-8HN31-0AA0 11-57, 7-52<br />

3VA6115-8HN31-2AA0 11-58<br />

3VA6115-8HN41-0AA0 7-53<br />

3VA6115-8JP31-0AA0 7-52<br />

3VA6115-8JP41-0AA0 7-53<br />

3VA6115-8JQ31-0AA0 7-52<br />

3VA6115-8JQ41-0AA0 7-53<br />

3VA6115-8JT31-0AA0 7-52<br />

3VA6115-8JT41-0AA0 7-53<br />

3VA6115-8KL31-0AA0 7-52<br />

3VA6115-8KL41-0AA0 7-53<br />

3VA6115-8KM31-0AA0 7-52<br />

3VA6115-8KM41-0AA0 7-53<br />

3VA6115-8KP31-0AA0 7-52<br />

3VA6115-8KP41-0AA0 7-53<br />

3VA6115-8KQ31-0AA0 7-52<br />

3VA6115-8KQ41-0AA0 7-53<br />

3VA6115-8KT31-0AA0 7-52<br />

3VA6115-8KT41-0AA0 7-53<br />

3VA6125-1MS31-0AA0 7-80<br />

3VA6130-1MS31-0AA0 7-80<br />

3VA6140-1MS31-0AA0 7-80<br />

3VA6140-5HL31-0AA0 7-52<br />

3VA6140-5HL41-0AA0 7-53<br />

3VA6140-5HM31-0AA0 7-52<br />

3VA6140-5HM41-0AA0 7-53<br />

3VA6140-5HN31-0AA0 11-57, 7-52<br />

3VA6140-5HN31-2AA0 11-58<br />

3VA6140-5HN41-0AA0 7-53<br />

3VA6140-5JP31-0AA0 7-52<br />

3VA6140-5JP41-0AA0 7-53<br />

3VA6140-5JQ31-0AA0 7-52<br />

3VA6140-5JQ41-0AA0 7-53<br />

3VA6140-5JT31-0AA0 7-52<br />

3VA6140-5JT41-0AA0 7-53<br />

3VA6140-5KL31-0AA0 7-52<br />

3VA6140-5KL41-0AA0 7-53<br />

3VA6140-5KM31-0AA0 7-52<br />

3VA6140-5KM41-0AA0 7-53<br />

3VA6140-5KP31-0AA0 7-52<br />

3VA6140-5KP41-0AA0 7-53<br />

3VA6140-5KQ31-0AA0 7-52<br />

3VA6140-5KQ41-0AA0 7-53<br />

3VA6140-5KT31-0AA0 7-52<br />

3VA6140-5KT41-0AA0 7-53<br />

3VA6140-6HL31-0AA0 7-52<br />

3VA6140-6HL41-0AA0 7-53<br />

3VA6140-6HM31-0AA0 7-52<br />

3VA6140-6HM41-0AA0 7-53<br />

3VA6140-6HN31-0AA0 11-57, 7-52<br />

3VA6140-6HN31-2AA0 11-58<br />

3VA6140-6HN41-0AA0 7-53<br />

3VA6140-6JP31-0AA0 7-52<br />

3VA6140-6JP41-0AA0 7-53<br />

3VA6140-6JQ31-0AA0 7-52<br />

3VA6140-6JQ41-0AA0 7-53<br />

3VA6140-6JT31-0AA0 7-52<br />

3VA6140-6JT41-0AA0 7-53<br />

3VA6140-6KL31-0AA0 7-52<br />

3VA6140-6KL41-0AA0 7-53<br />

3VA6140-6KM31-0AA0 7-52<br />

3VA6140-6KM41-0AA0 7-53<br />

3VA6140-6KP31-0AA0 7-52<br />

3VA6140-6KP41-0AA0 7-53<br />

3VA6140-6KQ31-0AA0 7-52<br />

3VA6140-6KQ41-0AA0 7-53<br />

3VA6140-6KT31-0AA0 7-52<br />

3VA6140-6KT41-0AA0 7-53<br />

3VA6140-7HL31-0AA0 7-52<br />

3VA6140-7HL41-0AA0 7-53<br />

3VA6140-7HM31-0AA0 7-52<br />

3VA6140-7HM41-0AA0 7-53<br />

3VA6140-7HN31-0AA0 11-57, 7-52<br />

3VA6140-7HN31-2AA0 11-58<br />

3VA6140-7HN41-0AA0 7-53<br />

3VA6140-7JP31-0AA0 7-52<br />

3VA6140-7JP41-0AA0 7-53<br />

3VA6140-7JQ31-0AA0 7-52<br />

3VA6140-7JQ41-0AA0 7-53<br />

3VA6140-7JT31-0AA0 7-52<br />

3VA6140-7JT41-0AA0 7-53<br />

3VA6140-7KL31-0AA0 7-52<br />

3VA6140-7KL41-0AA0 7-53<br />

3VA6140-7KM31-0AA0 7-52<br />

3VA6140-7KM41-0AA0 7-53<br />

3VA6140-7KP31-0AA0 7-52<br />

3VA6140-7KP41-0AA0 7-53<br />

3VA6140-7KQ31-0AA0 7-52<br />

3VA6140-7KQ41-0AA0 7-53<br />

3VA6140-7KT31-0AA0 7-52<br />

3VA6140-7KT41-0AA0 7-53<br />

3VA6140-8HL31-0AA0 7-52<br />

3VA6140-8HL41-0AA0 7-53<br />

3VA6140-8HM31-0AA0 7-52<br />

3VA6140-8HM41-0AA0 7-53<br />

3VA6140-8HN31-0AA0 11-57, 7-52<br />

3VA6140-8HN31-2AA0 11-58<br />

3VA6140-8HN41-0AA0 7-53<br />

3VA6140-8JP31-0AA0 7-52<br />

3VA6140-8JP41-0AA0 7-53<br />

3VA6140-8JQ31-0AA0 7-52<br />

3VA6140-8JQ41-0AA0 7-53<br />

3VA6140-8JT31-0AA0 7-52<br />

3VA6140-8JT41-0AA0 7-53<br />

3VA6140-8KL31-0AA0 7-52<br />

3VA6140-8KL41-0AA0 7-53<br />

3VA6140-8KM31-0AA0 7-52<br />

3VA6140-8KM41-0AA0 7-53<br />

3VA6140-8KP31-0AA0 7-52<br />

3VA6140-8KP41-0AA0 7-53<br />

3VA6140-8KQ31-0AA0 7-52<br />

3VA6140-8KQ41-0AA0 7-53<br />

3VA6140-8KT31-0AA0 7-52<br />

3VA6140-8KT41-0AA0 7-53<br />

3VA6150-1MS31-0AA0 7-80<br />

3VA6160-0HL31-0AA0 7-52<br />

3VA6160-0HL41-0AA0 7-53<br />

3VA6160-0HM31-0AA0 7-52<br />

3VA6160-0HM41-0AA0 7-53<br />

3VA6160-0HN31-0AA0 7-52<br />

3VA6160-0HN41-0AA0 7-53<br />

3VA6160-0KQ31-0AA0 7-52<br />

3VA6160-0KQ41-0AA0 7-53<br />

3VA6160-0KT31-0AA0 7-52<br />

3VA6160-0KT41-0AA0 7-53<br />

3VA6170-1MS31-0AA0 7-80<br />

3VA6180-1MS31-0AA0 7-80<br />

3VA6190-1MS31-0AA0 7-80<br />

3VA6210-5HL31-0AA0 7-60<br />

3VA6210-5HL41-0AA0 7-61<br />

3VA6210-5HM31-0AA0 7-60<br />

3VA6210-5HM41-0AA0 7-61<br />

3VA6210-5HN31-0AA0 11-57, 7-60<br />

3VA6210-5HN31-2AA0 11-58<br />

3VA6210-5HN41-0AA0 7-61<br />

3VA6210-5JP31-0AA0 7-60<br />

3VA6210-5JP41-0AA0 7-61<br />

3VA6210-5JQ31-0AA0 7-60<br />

3VA6210-5JQ41-0AA0 7-61<br />

3VA6210-5JT31-0AA0 7-60<br />

3VA6210-5JT41-0AA0 7-61<br />

3VA6210-5KL31-0AA0 7-60<br />

3VA6210-5KL41-0AA0 7-61<br />

3VA6210-5KM31-0AA0 7-60<br />

3VA6210-5KM41-0AA0 7-61<br />

3VA6210-5KP31-0AA0 7-60<br />

3VA6210-5KP41-0AA0 7-61<br />

3VA6210-5KQ31-0AA0 7-60<br />

3VA6210-5KQ41-0AA0 7-61<br />

3VA6210-5KT31-0AA0 7-60<br />

3VA6210-5KT41-0AA0 7-61<br />

3VA6210-6HL31-0AA0 7-60<br />

3VA6210-6HL41-0AA0 7-61<br />

3VA6210-6HM31-0AA0 7-60<br />

3VA6210-6HM41-0AA0 7-61<br />

3VA6210-6HN31-0AA0 11-57, 7-60<br />

3VA6210-6HN31-2AA0 11-58<br />

3VA6210-6HN41-0AA0 7-61<br />

3VA6210-6JP31-0AA0 7-60<br />

3VA6210-6JP41-0AA0 7-61<br />

3VA6210-6JQ31-0AA0 7-60<br />

3VA6210-6JQ41-0AA0 7-61<br />

3VA6210-6JT31-0AA0 7-60<br />

3VA6210-6JT41-0AA0 7-61<br />

3VA6210-6KL31-0AA0 7-60<br />

3VA6210-6KL41-0AA0 7-61<br />

3VA6210-6KM31-0AA0 7-60<br />

3VA6210-6KM41-0AA0 7-61<br />

3VA6210-6KP31-0AA0 7-60<br />

3VA6210-6KP41-0AA0 7-61<br />

3VA6210-6KQ31-0AA0 7-60<br />

3VA6210-6KQ41-0AA0 7-61<br />

3VA6210-6KT31-0AA0 7-60<br />

3VA6210-6KT41-0AA0 7-61<br />

3VA6210-7HL31-0AA0 7-60<br />

3VA6210-7HL41-0AA0 7-61<br />

3VA6210-7HM31-0AA0 7-60<br />

3VA6210-7HM41-0AA0 7-61<br />

3VA6210-7HN31-0AA0 11-57, 7-60<br />

3VA6210-7HN31-2AA0 11-58<br />

3VA6210-7HN41-0AA0 7-61<br />

3VA6210-7JP31-0AA0 7-60<br />

3VA6210-7JP41-0AA0 7-61<br />

3VA6210-7JQ31-0AA0 7-60<br />

3VA6210-7JQ41-0AA0 7-61<br />

3VA6210-7JT31-0AA0 7-60<br />

3VA6210-7JT41-0AA0 7-61<br />

3VA6210-7KL31-0AA0 7-60<br />

3VA6210-7KL41-0AA0 7-61<br />

3VA6210-7KM31-0AA0 7-60<br />

3VA6210-7KM41-0AA0 7-61<br />

3VA6210-7KP31-0AA0 7-60<br />

3VA6210-7KP41-0AA0 7-61<br />

3VA6210-7KQ31-0AA0 7-60<br />

3VA6210-7KQ41-0AA0 7-61<br />

3VA6210-7KT31-0AA0 7-60<br />

3VA6210-7KT41-0AA0 7-61<br />

3VA6210-8HL31-0AA0 7-60<br />

3VA6210-8HL41-0AA0 7-61<br />

3VA6210-8HM31-0AA0 7-60<br />

3VA6210-8HM41-0AA0 7-61<br />

3VA6210-8HN31-0AA0 11-57, 7-60<br />

3VA6210-8HN31-2AA0 11-58<br />

3VA6210-8HN41-0AA0 7-61<br />

3VA6210-8JP31-0AA0 7-60<br />

3VA6210-8JP41-0AA0 7-61<br />

3VA6210-8JQ31-0AA0 7-60<br />

3VA6210-8JQ41-0AA0 7-61<br />

3VA6210-8JT31-0AA0 7-60<br />

3VA6210-8JT41-0AA0 7-61<br />

3VA6210-8KL31-0AA0 7-60<br />

3VA6210-8KL41-0AA0 7-61<br />

3VA6210-8KM31-0AA0 7-60<br />

3VA6210-8KM41-0AA0 7-61<br />

3VA6210-8KP31-0AA0 7-60<br />

3VA6210-8KP41-0AA0 7-61<br />

3VA6210-8KQ31-0AA0 7-60<br />

3VA6210-8KQ41-0AA0 7-61<br />

3VA6210-8KT31-0AA0 7-60<br />

3VA6210-8KT41-0AA0 7-61<br />

3VA6211-1MS31-0AA0 7-80<br />

3VA6212-1MS31-0AA0 7-80<br />

3VA6215-1MS31-0AA0 7-80<br />

3VA6220-1MS31-0AA0 7-80<br />

3VA6225-0HL31-0AA0 7-60<br />

3VA6225-0HL41-0AA0 7-61<br />

3VA6225-0HM31-0AA0 7-60<br />

3VA6225-0HM41-0AA0 7-61<br />

3VA6225-0HN31-0AA0 7-60<br />

3VA6225-0HN41-0AA0 7-61<br />

3VA6225-0KQ31-0AA0 7-60<br />

3VA6225-0KQ41-0AA0 7-61<br />

3VA6225-0KT31-0AA0 7-60<br />

3VA6225-0KT41-0AA0 7-61<br />

3VA6225-5HL31-0AA0 7-60<br />

3VA6225-5HL41-0AA0 7-61<br />

3VA6225-5HM31-0AA0 7-60<br />

I<br />

PRODUCT<br />

INDEX<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog I-5


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

I<br />

PRODUCT<br />

INDEX<br />

3VA6225-5HM41-0AA0 7-61<br />

3VA6225-5HN31-0AA0 11-57, 7-60<br />

3VA6225-5HN31-2AA0 11-58<br />

3VA6225-5HN41-0AA0 7-61<br />

3VA6225-5JP31-0AA0 7-60<br />

3VA6225-5JP41-0AA0 7-61<br />

3VA6225-5JQ31-0AA0 7-60<br />

3VA6225-5JQ41-0AA0 7-61<br />

3VA6225-5JT31-0AA0 7-60<br />

3VA6225-5JT41-0AA0 7-61<br />

3VA6225-5KL31-0AA0 7-60<br />

3VA6225-5KL41-0AA0 7-61<br />

3VA6225-5KM31-0AA0 7-60<br />

3VA6225-5KM41-0AA0 7-61<br />

3VA6225-5KP31-0AA0 7-60<br />

3VA6225-5KP41-0AA0 7-61<br />

3VA6225-5KQ31-0AA0 7-60<br />

3VA6225-5KQ41-0AA0 7-61<br />

3VA6225-5KT31-0AA0 7-60<br />

3VA6225-5KT41-0AA0 7-61<br />

3VA6225-6HL31-0AA0 7-60<br />

3VA6225-6HL41-0AA0 7-61<br />

3VA6225-6HM31-0AA0 7-60<br />

3VA6225-6HM41-0AA0 7-61<br />

3VA6225-6HN31-0AA0 11-57, 7-60<br />

3VA6225-6HN31-2AA0 11-58<br />

3VA6225-6HN41-0AA0 7-61<br />

3VA6225-6JP31-0AA0 7-60<br />

3VA6225-6JP41-0AA0 7-61<br />

3VA6225-6JQ31-0AA0 7-60<br />

3VA6225-6JQ41-0AA0 7-61<br />

3VA6225-6JT31-0AA0 7-60<br />

3VA6225-6JT41-0AA0 7-61<br />

3VA6225-6KL31-0AA0 7-60<br />

3VA6225-6KL41-0AA0 7-61<br />

3VA6225-6KM31-0AA0 7-60<br />

3VA6225-6KM41-0AA0 7-61<br />

3VA6225-6KP31-0AA0 7-60<br />

3VA6225-6KP41-0AA0 7-61<br />

3VA6225-6KQ31-0AA0 7-60<br />

3VA6225-6KQ41-0AA0 7-61<br />

3VA6225-6KT31-0AA0 7-60<br />

3VA6225-6KT41-0AA0 7-61<br />

3VA6225-7HL31-0AA0 7-60<br />

3VA6225-7HL41-0AA0 7-61<br />

3VA6225-7HM31-0AA0 7-60<br />

3VA6225-7HM41-0AA0 7-61<br />

3VA6225-7HN31-0AA0 11-57, 7-60<br />

3VA6225-7HN31-2AA0 11-58<br />

3VA6225-7HN41-0AA0 7-61<br />

3VA6225-7JP31-0AA0 7-60<br />

3VA6225-7JP41-0AA0 7-61<br />

3VA6225-7JQ31-0AA0 7-60<br />

3VA6225-7JQ41-0AA0 7-61<br />

3VA6225-7JT31-0AA0 7-60<br />

3VA6225-7JT41-0AA0 7-61<br />

3VA6225-7KL31-0AA0 7-60<br />

3VA6225-7KL41-0AA0 7-61<br />

3VA6225-7KM31-0AA0 7-60<br />

3VA6225-7KM41-0AA0 7-61<br />

3VA6225-7KP31-0AA0 7-60<br />

3VA6225-7KP41-0AA0 7-61<br />

3VA6225-7KQ31-0AA0 7-60<br />

3VA6225-7KQ41-0AA0 7-61<br />

3VA6225-7KT31-0AA0 7-60<br />

3VA6225-7KT41-0AA0 7-61<br />

3VA6225-8HL31-0AA0 7-60<br />

3VA6225-8HL41-0AA0 7-61<br />

3VA6225-8HM31-0AA0 7-60<br />

3VA6225-8HM41-0AA0 7-61<br />

3VA6225-8HN31-0AA0 11-57, 7-60<br />

3VA6225-8HN31-2AA0 11-58<br />

3VA6225-8HN41-0AA0 7-61<br />

3VA6225-8JP31-0AA0 7-60<br />

3VA6225-8JP41-0AA0 7-61<br />

3VA6225-8JQ31-0AA0 7-60<br />

3VA6225-8JQ41-0AA0 7-61<br />

3VA6225-8JT31-0AA0 7-60<br />

3VA6225-8JT41-0AA0 7-61<br />

3VA6225-8KL31-0AA0 7-60<br />

3VA6225-8KL41-0AA0 7-61<br />

3VA6225-8KM31-0AA0 7-60<br />

3VA6225-8KM41-0AA0 7-61<br />

3VA6225-8KP31-0AA0 7-60<br />

3VA6225-8KP41-0AA0 7-61<br />

3VA6225-8KQ31-0AA0 7-60<br />

3VA6225-8KQ41-0AA0 7-61<br />

3VA6225-8KT31-0AA0 7-60<br />

3VA6225-8KT41-0AA0 7-61<br />

3VA6320-1MS31-0AA0 7-80<br />

3VA6325-0HL31-0AA0 7-66, 7-67<br />

3VA6325-0HM31-0AA0 7-66, 7-67<br />

3VA6325-0HN31-0AA0 7-66, 7-67<br />

3VA6325-0KQ31-0AA0 7-66, 7-67<br />

3VA6325-0KT31-0AA0 7-66, 7-67<br />

3VA6325-1MS31-0AA0 7-80<br />

3VA6325-5HL31-0AA0 7-66<br />

3VA6325-5HL41-0AA0 7-67<br />

3VA6325-5HM31-0AA0 7-66<br />

3VA6325-5HM41-0AA0 7-67<br />

3VA6325-5HN31-0AA0 11-57, 7-66<br />

3VA6325-5HN31-2AA0 11-58<br />

3VA6325-5HN41-0AA0 7-67<br />

3VA6325-5JP31-0AA0 7-66<br />

3VA6325-5JP41-0AA0 7-67<br />

3VA6325-5JQ31-0AA0 7-66<br />

3VA6325-5JQ41-0AA0 7-67<br />

3VA6325-5JT31-0AA0 7-66<br />

3VA6325-5JT41-0AA0 7-67<br />

3VA6325-5KL31-0AA0 7-66<br />

3VA6325-5KL41-0AA0 7-67<br />

3VA6325-5KM31-0AA0 7-66<br />

3VA6325-5KM41-0AA0 7-67<br />

3VA6325-5KP31-0AA0 7-66<br />

3VA6325-5KP41-0AA0 7-67<br />

3VA6325-5KQ31-0AA0 7-66<br />

3VA6325-5KQ41-0AA0 7-67<br />

3VA6325-5KT31-0AA0 7-66<br />

3VA6325-5KT41-0AA0 7-67<br />

3VA6325-6HL31-0AA0 7-66<br />

3VA6325-6HL41-0AA0 7-67<br />

3VA6325-6HM31-0AA0 7-66<br />

3VA6325-6HM41-0AA0 7-67<br />

3VA6325-6HN31-0AA0 11-57, 7-66<br />

3VA6325-6HN31-2AA0 11-58<br />

3VA6325-6HN41-0AA0 7-67<br />

3VA6325-6JP31-0AA0 7-66<br />

3VA6325-6JP41-0AA0 7-67<br />

3VA6325-6JQ31-0AA0 7-66<br />

3VA6325-6JQ41-0AA0 7-67<br />

3VA6325-6JT31-0AA0 7-66<br />

3VA6325-6JT41-0AA0 7-67<br />

3VA6325-6KL31-0AA0 7-66<br />

3VA6325-6KL41-0AA0 7-67<br />

3VA6325-6KM31-0AA0 7-66<br />

3VA6325-6KM41-0AA0 7-67<br />

3VA6325-6KP31-0AA0 7-66<br />

3VA6325-6KP41-0AA0 7-67<br />

3VA6325-6KQ31-0AA0 7-66<br />

3VA6325-6KQ41-0AA0 7-67<br />

3VA6325-6KT31-0AA0 7-66<br />

3VA6325-6KT41-0AA0 7-67<br />

3VA6325-7HL31-0AA0 7-66<br />

3VA6325-7HL41-0AA0 7-67<br />

3VA6325-7HM31-0AA0 7-66<br />

3VA6325-7HM41-0AA0 7-67<br />

3VA6325-7HN31-0AA0 11-57, 7-66<br />

3VA6325-7HN31-2AA0 11-58<br />

3VA6325-7HN41-0AA0 7-67<br />

3VA6325-7JP31-0AA0 7-66<br />

3VA6325-7JP41-0AA0 7-67<br />

3VA6325-7JQ31-0AA0 7-66<br />

3VA6325-7JQ41-0AA0 7-67<br />

3VA6325-7JT31-0AA0 7-66<br />

3VA6325-7JT41-0AA0 7-67<br />

3VA6325-7KL31-0AA0 7-66<br />

3VA6325-7KL41-0AA0 7-67<br />

3VA6325-7KM31-0AA0 7-66<br />

3VA6325-7KM41-0AA0 7-67<br />

3VA6325-7KP31-0AA0 7-66<br />

3VA6325-7KP41-0AA0 7-67<br />

3VA6325-7KQ31-0AA0 7-66<br />

3VA6325-7KQ41-0AA0 7-67<br />

3VA6325-7KT31-0AA0 7-66<br />

3VA6325-7KT41-0AA0 7-67<br />

3VA6325-8HL31-0AA0 7-66<br />

3VA6325-8HL41-0AA0 7-67<br />

3VA6325-8HM31-0AA0 7-66<br />

3VA6325-8HM41-0AA0 7-67<br />

3VA6325-8HN31-0AA0 11-57, 7-66<br />

3VA6325-8HN31-2AA0 11-58<br />

3VA6325-8HN41-0AA0 7-67<br />

3VA6325-8JP31-0AA0 7-66<br />

3VA6325-8JP41-0AA0 7-67<br />

3VA6325-8JQ31-0AA0 7-66<br />

3VA6325-8JQ41-0AA0 7-67<br />

3VA6325-8JT31-0AA0 7-66<br />

3VA6325-8JT41-0AA0 7-67<br />

3VA6325-8KL31-0AA0 7-66<br />

3VA6325-8KL41-0AA0 7-67<br />

3VA6325-8KM31-0AA0 7-66<br />

3VA6325-8KM41-0AA0 7-67<br />

3VA6325-8KP31-0AA0 7-66<br />

3VA6325-8KP41-0AA0 7-67<br />

3VA6325-8KQ31-0AA0 7-66<br />

3VA6325-8KQ41-0AA0 7-67<br />

3VA6325-8KT31-0AA0 7-66<br />

3VA6325-8KT41-0AA0 7-67<br />

3VA6340-0HL31-0AA0 7-66, 7-67<br />

3VA6340-0HM31-0AA0 7-66, 7-67<br />

3VA6340-0HN31-0AA0 7-66, 7-67<br />

3VA6340-0KQ31-0AA0 7-66, 7-67<br />

3VA6340-0KT31-0AA0 7-66, 7-67<br />

3VA6340-1BB31-0AA0 7-79<br />

3VA6340-5HL31-0AA0 7-66<br />

3VA6340-5HL41-0AA0 7-67<br />

3VA6340-5HM31-0AA0 7-66<br />

3VA6340-5HM41-0AA0 7-67<br />

3VA6340-5HN31-0AA0 11-57, 7-66<br />

3VA6340-5HN41-0AA0 7-67<br />

3VA6340-5JP31-0AA0 7-66<br />

3VA6340-5JP41-0AA0 7-67<br />

3VA6340-5JQ31-0AA0 7-66<br />

3VA6340-5JQ41-0AA0 7-67<br />

3VA6340-5JT31-0AA0 7-66<br />

3VA6340-5JT41-0AA0 7-67<br />

3VA6340-5KL31-0AA0 7-66<br />

3VA6340-5KL41-0AA0 7-67<br />

3VA6340-5KM31-0AA0 7-66<br />

3VA6340-5KM41-0AA0 7-67<br />

3VA6340-5KP31-0AA0 7-66<br />

3VA6340-5KP41-0AA0 7-67<br />

3VA6340-5KQ31-0AA0 7-66<br />

3VA6340-5KQ41-0AA0 7-67<br />

3VA6340-5KT31-0AA0 7-66<br />

3VA6340-5KT41-0AA0 7-67<br />

3VA6340-6HL31-0AA0 7-66<br />

3VA6340-6HL41-0AA0 7-67<br />

3VA6340-6HM31-0AA0 7-66<br />

3VA6340-6HM41-0AA0 7-67<br />

3VA6340-6HN31-0AA0 11-57, 7-66<br />

3VA6340-6HN41-0AA0 7-67<br />

3VA6340-6JP31-0AA0 7-66<br />

3VA6340-6JP41-0AA0 7-67<br />

3VA6340-6JQ31-0AA0 7-66<br />

3VA6340-6JQ41-0AA0 7-67<br />

3VA6340-6JT31-0AA0 7-66<br />

3VA6340-6JT41-0AA0 7-67<br />

3VA6340-6KL31-0AA0 7-66<br />

3VA6340-6KL41-0AA0 7-67<br />

3VA6340-6KM31-0AA0 7-66<br />

3VA6340-6KM41-0AA0 7-67<br />

3VA6340-6KP31-0AA0 7-66<br />

3VA6340-6KP41-0AA0 7-67<br />

3VA6340-6KQ31-0AA0 7-66<br />

3VA6340-6KQ41-0AA0 7-67<br />

3VA6340-6KT31-0AA0 7-66<br />

3VA6340-6KT41-0AA0 7-67<br />

3VA6340-7HL31-0AA0 7-66<br />

3VA6340-7HL41-0AA0 7-67<br />

3VA6340-7HM31-0AA0 7-66<br />

3VA6340-7HM41-0AA0 7-67<br />

3VA6340-7HN31-0AA0 11-57, 7-66<br />

3VA6340-7HN41-0AA0 7-67<br />

3VA6340-7JP31-0AA0 7-66<br />

3VA6340-7JP41-0AA0 7-67<br />

3VA6340-7JQ31-0AA0 7-66<br />

3VA6340-7JQ41-0AA0 7-67<br />

3VA6340-7JT31-0AA0 7-66<br />

3VA6340-7JT41-0AA0 7-67<br />

3VA6340-7KL31-0AA0 7-66<br />

3VA6340-7KL41-0AA0 7-67<br />

3VA6340-7KM31-0AA0 7-66<br />

3VA6340-7KM41-0AA0 7-67<br />

3VA6340-7KP31-0AA0 7-66<br />

3VA6340-7KP41-0AA0 7-67<br />

3VA6340-7KQ31-0AA0 7-66<br />

3VA6340-7KQ41-0AA0 7-67<br />

3VA6340-7KT31-0AA0 7-66<br />

3VA6340-7KT41-0AA0 7-67<br />

3VA6340-8HL31-0AA0 7-66<br />

3VA6340-8HL41-0AA0 7-67<br />

3VA6340-8HM31-0AA0 7-66<br />

3VA6340-8HM41-0AA0 7-67<br />

3VA6340-8HN31-0AA0 11-57, 7-66<br />

3VA6340-8HN41-0AA0 7-67<br />

3VA6340-8JP31-0AA0 7-66<br />

3VA6340-8JP41-0AA0 7-67<br />

3VA6340-8JQ31-0AA0 7-66<br />

3VA6340-8JQ41-0AA0 7-67<br />

3VA6340-8JT31-0AA0 7-66<br />

3VA6340-8JT41-0AA0 7-67<br />

3VA6340-8KL31-0AA0 7-66<br />

3VA6340-8KL41-0AA0 7-67<br />

3VA6340-8KM31-0AA0 7-66<br />

3VA6340-8KM41-0AA0 7-67<br />

3VA6340-8KP31-0AA0 7-66<br />

3VA6340-8KP41-0AA0 7-67<br />

3VA6340-8KQ31-0AA0 7-66<br />

3VA6340-8KQ41-0AA0 7-67<br />

3VA6340-8KT31-0AA0 7-66<br />

3VA6340-8KT41-0AA0 7-67<br />

3VA6440-1MS31-0AA0 7-80<br />

3VA6440-5HL31-0AA0 7-70<br />

3VA6440-5HL41-0AA0 7-71<br />

3VA6440-5HM31-0AA0 7-70<br />

3VA6440-5HM41-0AA0 7-71<br />

3VA6440-5HN31-0AA0 11-57, 7-70<br />

3VA6440-5HN31-2AA0 11-58<br />

3VA6440-5HN41-0AA0 7-71<br />

3VA6440-5JP31-0AA0 7-70<br />

3VA6440-5JP41-0AA0 7-71<br />

3VA6440-5JQ31-0AA0 7-70<br />

3VA6440-5JQ41-0AA0 7-71<br />

3VA6440-5JT31-0AA0 7-70<br />

3VA6440-5JT41-0AA0 7-71<br />

3VA6440-5KL31-0AA0 7-70<br />

3VA6440-5KL41-0AA0 7-71<br />

3VA6440-5KM31-0AA0 7-70<br />

3VA6440-5KM41-0AA0 7-71<br />

3VA6440-5KP31-0AA0 7-70<br />

3VA6440-5KP41-0AA0 7-71<br />

3VA6440-5KQ31-0AA0 7-70<br />

3VA6440-5KQ41-0AA0 7-71<br />

3VA6440-5KT31-0AA0 7-70<br />

3VA6440-5KT41-0AA0 7-71<br />

3VA6440-6HL31-0AA0 7-70<br />

3VA6440-6HL41-0AA0 7-71<br />

3VA6440-6HM31-0AA0 7-70<br />

3VA6440-6HM41-0AA0 7-71<br />

3VA6440-6HN31-0AA0 11-57, 7-70<br />

3VA6440-6HN31-2AA0 11-58<br />

3VA6440-6HN41-0AA0 7-71<br />

3VA6440-6JP31-0AA0 7-70<br />

3VA6440-6JP41-0AA0 7-71<br />

3VA6440-6JQ31-0AA0 7-70<br />

3VA6440-6JQ41-0AA0 7-71<br />

3VA6440-6JT31-0AA0 7-70<br />

3VA6440-6JT41-0AA0 7-71<br />

3VA6440-6KL31-0AA0 7-70<br />

3VA6440-6KL41-0AA0 7-71<br />

3VA6440-6KM31-0AA0 7-70<br />

3VA6440-6KM41-0AA0 7-71<br />

3VA6440-6KP31-0AA0 7-70<br />

3VA6440-6KP41-0AA0 7-71<br />

3VA6440-6KQ31-0AA0 7-70<br />

3VA6440-6KQ41-0AA0 7-71<br />

3VA6440-6KT31-0AA0 7-70<br />

3VA6440-6KT41-0AA0 7-71<br />

3VA6440-7HL31-0AA0 7-70<br />

3VA6440-7HL41-0AA0 7-71<br />

3VA6440-7HM31-0AA0 7-70<br />

3VA6440-7HM41-0AA0 7-71<br />

3VA6440-7HN31-0AA0 11-57, 7-70<br />

3VA6440-7HN31-2AA0 11-58<br />

3VA6440-7HN41-0AA0 7-71<br />

3VA6440-7JP31-0AA0 7-70<br />

3VA6440-7JP41-0AA0 7-71<br />

3VA6440-7JQ31-0AA0 7-70<br />

3VA6440-7JQ41-0AA0 7-71<br />

3VA6440-7JT31-0AA0 7-70<br />

3VA6440-7JT41-0AA0 7-71<br />

3VA6440-7KL31-0AA0 7-70<br />

3VA6440-7KL41-0AA0 7-71<br />

3VA6440-7KM31-0AA0 7-70<br />

3VA6440-7KM41-0AA0 7-71<br />

3VA6440-7KP31-0AA0 7-70<br />

3VA6440-7KP41-0AA0 7-71<br />

3VA6440-7KQ31-0AA0 7-70<br />

3VA6440-7KQ41-0AA0 7-71<br />

3VA6440-7KT31-0AA0 7-70<br />

3VA6440-7KT41-0AA0 7-71<br />

3VA6440-8HL31-0AA0 7-70<br />

3VA6440-8HL41-0AA0 7-71<br />

3VA6440-8HM31-0AA0 7-70<br />

3VA6440-8HM41-0AA0 7-71<br />

3VA6440-8HN31-0AA0 11-57, 7-70<br />

3VA6440-8HN31-2AA0 11-58<br />

3VA6440-8HN41-0AA0 7-71<br />

3VA6440-8JP31-0AA0 7-70<br />

3VA6440-8JP41-0AA0 7-71<br />

3VA6440-8JQ31-0AA0 7-70<br />

3VA6440-8JQ41-0AA0 7-71<br />

3VA6440-8JT31-0AA0 7-70<br />

3VA6440-8JT41-0AA0 7-71<br />

3VA6440-8KL31-0AA0 7-70<br />

3VA6440-8KL41-0AA0 7-71<br />

3VA6440-8KM31-0AA0 7-70<br />

3VA6440-8KM41-0AA0 7-71<br />

3VA6440-8KP31-0AA0 7-70<br />

3VA6440-8KP41-0AA0 7-71<br />

3VA6440-8KQ31-0AA0 7-70<br />

3VA6440-8KQ41-0AA0 7-71<br />

3VA6440-8KT31-0AA0 7-70<br />

3VA6440-8KT41-0AA0 7-71<br />

3VA6450-1MS31-0AA0 7-80<br />

3VA6460-0HL31-0AA0 7-70<br />

3VA6460-0HL41-0AA0 7-71<br />

3VA6460-0HM31-0AA0 7-70<br />

3VA6460-0HM41-0AA0 7-71<br />

3VA6460-0HN31-0AA0 7-70<br />

3VA6460-0HN41-0AA0 7-71<br />

3VA6460-0KQ31-0AA0 7-70<br />

3VA6460-0KQ41-0AA0 7-71<br />

3VA6460-0KT31-0AA0 7-70<br />

3VA6460-0KT41-0AA0 7-71<br />

3VA6460-1BB31-0AA0 11-57, 7-79<br />

3VA6460-5HL31-0AA0 7-70<br />

3VA6460-5HL41-0AA0 7-71<br />

3VA6460-5HM31-0AA0 7-70<br />

3VA6460-5HM41-0AA0 7-71<br />

3VA6460-5HN31-0AA0 11-57, 7-70<br />

3VA6460-5HN41-0AA0 7-71<br />

3VA6460-5JP31-0AA0 7-70<br />

3VA6460-5JP41-0AA0 7-71<br />

3VA6460-5JQ31-0AA0 7-70<br />

3VA6460-5JQ41-0AA0 7-71<br />

3VA6460-5JT31-0AA0 7-70<br />

3VA6460-5JT41-0AA0 7-71<br />

3VA6460-5KL31-0AA0 7-70<br />

3VA6460-5KL41-0AA0 7-71<br />

3VA6460-5KM31-0AA0 7-70<br />

3VA6460-5KM41-0AA0 7-71<br />

3VA6460-5KP31-0AA0 7-70<br />

3VA6460-5KP41-0AA0 7-71<br />

3VA6460-5KQ31-0AA0 7-70<br />

3VA6460-5KQ41-0AA0 7-71<br />

3VA6460-5KT31-0AA0 7-70<br />

3VA6460-5KT41-0AA0 7-71<br />

3VA6460-6HL31-0AA0 7-70<br />

3VA6460-6HL41-0AA0 7-71<br />

3VA6460-6HM31-0AA0 7-70<br />

3VA6460-6HM41-0AA0 7-71<br />

3VA6460-6HN31-0AA0 11-57, 7-70<br />

3VA6460-6HN41-0AA0 7-71<br />

3VA6460-6JP31-0AA0 7-70<br />

3VA6460-6JP41-0AA0 7-71<br />

3VA6460-6JQ31-0AA0 7-70<br />

3VA6460-6JQ41-0AA0 7-71<br />

3VA6460-6JT31-0AA0 7-70<br />

3VA6460-6JT41-0AA0 7-71<br />

3VA6460-6KL31-0AA0 7-70<br />

3VA6460-6KL41-0AA0 7-71<br />

3VA6460-6KM31-0AA0 7-70<br />

3VA6460-6KM41-0AA0 7-71<br />

3VA6460-6KP31-0AA0 7-70<br />

3VA6460-6KP41-0AA0 7-71<br />

3VA6460-6KQ31-0AA0 7-70<br />

3VA6460-6KQ41-0AA0 7-71<br />

3VA6460-6KT31-0AA0 7-70<br />

3VA6460-6KT41-0AA0 7-71<br />

3VA6460-7HL31-0AA0 7-70<br />

3VA6460-7HL41-0AA0 7-71<br />

3VA6460-7HM31-0AA0 7-70<br />

3VA6460-7HM41-0AA0 7-71<br />

3VA6460-7HN31-0AA0 11-57, 7-70<br />

3VA6460-7HN41-0AA0 7-71<br />

3VA6460-7JP31-0AA0 7-70<br />

3VA6460-7JP41-0AA0 7-71<br />

3VA6460-7JQ31-0AA0 7-70<br />

3VA6460-7JQ41-0AA0 7-71<br />

3VA6460-7JT31-0AA0 7-70<br />

3VA6460-7JT41-0AA0 7-71<br />

3VA6460-7KL31-0AA0 7-70<br />

3VA6460-7KL41-0AA0 7-71<br />

3VA6460-7KM31-0AA0 7-70<br />

3VA6460-7KM41-0AA0 7-71<br />

3VA6460-7KP31-0AA0 7-70<br />

3VA6460-7KP41-0AA0 7-71<br />

3VA6460-7KQ31-0AA0 7-70<br />

I-6<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

3VA6460-7KQ41-0AA0 7-71<br />

3VA6460-7KT31-0AA0 7-70<br />

3VA6460-7KT41-0AA0 7-71<br />

3VA6460-8HL31-0AA0 7-70<br />

3VA6460-8HL41-0AA0 7-71<br />

3VA6460-8HM31-0AA0 7-70<br />

3VA6460-8HM41-0AA0 7-71<br />

3VA6460-8HN31-0AA0 11-57, 7-70<br />

3VA6460-8HN41-0AA0 7-71<br />

3VA6460-8JP31-0AA0 7-70<br />

3VA6460-8JP41-0AA0 7-71<br />

3VA6460-8JQ31-0AA0 7-70<br />

3VA6460-8JQ41-0AA0 7-71<br />

3VA6460-8JT31-0AA0 7-70<br />

3VA6460-8JT41-0AA0 7-71<br />

3VA6460-8KL31-0AA0 7-70<br />

3VA6460-8KL41-0AA0 7-71<br />

3VA6460-8KM31-0AA0 7-70<br />

3VA6460-8KM41-0AA0 7-71<br />

3VA6460-8KP31-0AA0 7-70<br />

3VA6460-8KP41-0AA0 7-71<br />

3VA6460-8KQ31-0AA0 7-70<br />

3VA6460-8KQ41-0AA0 7-71<br />

3VA6460-8KT31-0AA0 7-70<br />

3VA6460-8KT41-0AA0 7-71<br />

3VA6560-5HL32-0AA0 7-74<br />

3VA6560-5HM32-0AA0 7-74<br />

3VA6560-5HN32-0AA0 7-74<br />

3VA6560-5JP32-0AA0 7-74<br />

3VA6560-5JQ32-0AA0 7-74<br />

3VA6560-5JT32-0AA0 7-74<br />

3VA6560-5KL32-0AA0 7-74<br />

3VA6560-5KQ32-0AA0 7-74<br />

3VA6560-5KT32-0AA0 7-74<br />

3VA6560-6HL32-0AA0 7-74<br />

3VA6560-6HM32-0AA0 7-74<br />

3VA6560-6HN32-0AA0 7-74<br />

3VA6560-6JP32-0AA0 7-74<br />

3VA6560-6JQ32-0AA0 7-74<br />

3VA6560-6JT32-0AA0 7-74<br />

3VA6560-6KL32-0AA0 7-74<br />

3VA6560-6KQ32-0AA0 7-74<br />

3VA6560-6KT32-0AA0 7-74<br />

3VA6560-7HL32-0AA0 7-74<br />

3VA6560-7HM32-0AA0 7-74<br />

3VA6560-7HN32-0AA0 7-74<br />

3VA6560-7JP32-0AA0 7-74<br />

3VA6560-7JQ32-0AA0 7-74<br />

3VA6560-7JT32-0AA0 7-74<br />

3VA6560-7KL32-0AA0 7-74<br />

3VA6560-7KQ32-0AA0 7-74<br />

3VA6560-7KT32-0AA0 7-74<br />

3VA6580-1MS31-0AA0 7-80<br />

3VA6580-5HL32-0AA0 7-74<br />

3VA6580-5HM32-0AA0 7-74<br />

3VA6580-5HN32-0AA0 7-74<br />

3VA6580-5JP32-0AA0 7-74<br />

3VA6580-5JQ32-0AA0 7-74<br />

3VA6580-5JT32-0AA0 7-74<br />

3VA6580-5KL32-0AA0 7-74<br />

3VA6580-5KQ32-0AA0 7-74<br />

3VA6580-5KT32-0AA0 7-74<br />

3VA6580-6HL32-0AA0 7-74<br />

3VA6580-6HM32-0AA0 7-74<br />

3VA6580-6HN32-0AA0 7-74<br />

3VA6580-6JP32-0AA0 7-74<br />

3VA6580-6JQ32-0AA0 7-74<br />

3VA6580-6JT32-0AA0 7-74<br />

3VA6580-6KL32-0AA0 7-74<br />

3VA6580-6KQ32-0AA0 7-74<br />

3VA6580-6KT32-0AA0 7-74<br />

3VA6580-7HL32-0AA0 7-74<br />

3VA6580-7HM32-0AA0 7-74<br />

3VA6580-7HN32-0AA0 7-74<br />

3VA6580-7JP32-0AA0 7-74<br />

3VA6580-7JQ32-0AA0 7-74<br />

3VA6580-7JT32-0AA0 7-74<br />

3VA6580-7KL32-0AA0 7-74<br />

3VA6580-7KQ32-0AA0 7-74<br />

3VA6580-7KT32-0AA0 7-74<br />

3VA6610-5HL32-0AA0 7-77<br />

3VA6610-5HL42-0AA0 7-78<br />

3VA6610-5HM32-0AA0 7-77<br />

3VA6610-5HM42-0AA0 7-78<br />

3VA6610-5HN32-0AA0 7-77<br />

3VA6610-5HN42-0AA0 7-78<br />

3VA6610-5JP32-0AA0 7-77<br />

3VA6610-5JP42-0AA0 7-78<br />

3VA6610-5JQ32-0AA0 7-77<br />

3VA6610-5JQ42-0AA0 7-78<br />

3VA6610-5JT32-0AA0 7-77<br />

3VA6610-5JT42-0AA0 7-78<br />

3VA6610-5KL32-0AA0 7-77<br />

3VA6610-5KL42-0AA0 7-78<br />

3VA6610-5KQ32-0AA0 7-77<br />

3VA6610-5KQ42-0AA0 7-78<br />

3VA6610-5KT32-0AA0 7-77<br />

3VA6610-5KT42-0AA0 7-78<br />

3VA6610-6HL32-0AA0 7-77<br />

3VA6610-6HL42-0AA0 7-78<br />

3VA6610-6HM32-0AA0 7-77<br />

3VA6610-6HM42-0AA0 7-78<br />

3VA6610-6HN32-0AA0 7-77<br />

3VA6610-6HN42-0AA0 7-78<br />

3VA6610-6JP32-0AA0 7-77<br />

3VA6610-6JP42-0AA0 7-78<br />

3VA6610-6JQ32-0AA0 7-77<br />

3VA6610-6JQ42-0AA0 7-78<br />

3VA6610-6JT32-0AA0 7-77<br />

3VA6610-6JT42-0AA0 7-78<br />

3VA6610-6KL32-0AA0 7-77<br />

3VA6610-6KL42-0AA0 7-78<br />

3VA6610-6KQ32-0AA0 7-77<br />

3VA6610-6KQ42-0AA0 7-78<br />

3VA6610-6KT32-0AA0 7-77<br />

3VA6610-6KT42-0AA0 7-78<br />

3VA6610-7HL32-0AA0 7-77<br />

3VA6610-7HL42-0AA0 7-78<br />

3VA6610-7HM32-0AA0 7-77<br />

3VA6610-7HM42-0AA0 7-78<br />

3VA6610-7HN32-0AA0 7-77<br />

3VA6610-7HN42-0AA0 7-78<br />

3VA6610-7JP32-0AA0 7-77<br />

3VA6610-7JP42-0AA0 7-78<br />

3VA6610-7JQ32-0AA0 7-77<br />

3VA6610-7JQ42-0AA0 7-78<br />

3VA6610-7JT32-0AA0 7-77<br />

3VA6610-7JT42-0AA0 7-78<br />

3VA6610-7KL32-0AA0 7-77<br />

3VA6610-7KL42-0AA0 7-78<br />

3VA6610-7KQ32-0AA0 7-77<br />

3VA6610-7KQ42-0AA0 7-78<br />

3VA6610-7KT32-0AA0 7-77<br />

3VA6610-7KT42-0AA0 7-78<br />

3VA9033-0SB10 7-105<br />

3VA9033-0SB20 7-105<br />

3VA9034-0SB10 7-105<br />

3VA9034-0SB20 7-105<br />

3VA9038-0LB10 7-104<br />

3VA9038-0LB11 7-104, 7-37<br />

3VA9077-0NA10 11-59, 7-102<br />

3VA9078-0VK10 7-105<br />

3VA9078-0VM10 7-104<br />

3VA9078-0VM30 7-104<br />

3VA9087-0SX10 7-105, 7-86<br />

3VA9114-0SS10 7-106<br />

3VA9116-0SS10 7-106<br />

3VA9124-0SS10 7-106<br />

3VA9126-0SS10 7-106<br />

3VA9131-0QB00 7-93<br />

3VA9131-0QE10 7-94<br />

3VA9131-0QE20 7-94<br />

3VA9131-0QF10 7-94<br />

3VA9131-0QF20 7-94<br />

3VA9131-0WD10 7-95<br />

3VA9131-0WD20 7-95<br />

3VA9131-0WD30 7-95<br />

3VA9131-0WD31 7-95<br />

3VA9131-0WD40 7-95<br />

3VA9131-0WF20 7-95<br />

3VA9131-0WF30 7-95<br />

3VA9131-0WF31 7-95<br />

3VA9131-0WF40 7-95<br />

3VA9131-0WJ20 7-96<br />

3VA9131-0WJ30 7-96<br />

3VA9131-0WJ40 7-96<br />

3VA9132-0JC12 7-89<br />

3VA9132-0JF60 7-90<br />

3VA9132-0JJ12 7-89<br />

3VA9132-0WA00 7-95<br />

3VA9133-0JA11 7-37, 7-51, 7-88<br />

3VA9133-0JB10 7-37, 7-51, 7-88<br />

3VA9133-0JB11 11-62, 7-37, 7-51, 7-88<br />

3VA9133-0JC12 7-51, 7-89<br />

3VA9133-0JC18 7-89<br />

3VA9133-0JD10 7-37, 7-51, 7-91<br />

3VA9133-0JD11 11-62, 7-37, 7-51, 7-91<br />

3VA9133-0JF60 7-51, 7-90<br />

3VA9133-0JF68 7-90<br />

3VA9133-0JG10 7-37, 7-51, 7-88<br />

3VA9133-0JG11 11-59, 7-37, 7-51, 7-88<br />

3VA9133-0JJ12 7-51, 7-89<br />

3VA9133-0JK10 7-37, 7-51, 7-91<br />

3VA9133-0JK11 11-59, 7-37, 7-51, 7-91<br />

3VA9133-0QA00 7-92<br />

3VA9133-0QB00 7-93<br />

3VA9133-0QE00 7-94<br />

3VA9133-0QF00 7-94<br />

3VA9134-0JA11 7-51, 7-88<br />

3VA9134-0JB10 7-51, 7-88<br />

3VA9134-0JB11 7-51, 7-88<br />

3VA9134-0JC12 7-89<br />

3VA9134-0JD10 7-51, 7-91<br />

3VA9134-0JD11 7-51, 7-91<br />

3VA9134-0JF60 7-51, 7-90<br />

3VA9134-0JG10 7-51, 7-88<br />

3VA9134-0JG11 7-51, 7-88<br />

3VA9134-0JJ12 7-51, 7-89<br />

3VA9134-0JK10 7-51, 7-91<br />

3VA9134-0JK11 7-51, 7-91<br />

3VA9134-0QA00 7-92<br />

3VA9134-0QE00 7-94<br />

3VA9134-0QF00 7-94<br />

3VA9137-0CB10 7-87<br />

3VA9137-0CK12 7-87<br />

3VA9137-0CK72 7-87<br />

3VA9137-0EK11 7-82<br />

3VA9137-0EK13 7-82<br />

3VA9137-0EK15 7-82<br />

3VA9137-0EK17 7-82<br />

3VA9137-0EK21 7-82<br />

3VA9137-0EK23 7-82<br />

3VA9137-0EK25 7-82<br />

3VA9137-0EK27 7-82<br />

3VA9137-0EK31 7-82<br />

3VA9137-0EK33 7-82<br />

3VA9137-0EK35 7-82<br />

3VA9137-0EK37 7-82<br />

3VA9137-0FK21 7-83<br />

3VA9137-0FK23 7-83<br />

3VA9137-0FK25 7-83<br />

3VA9137-0FK27 7-83<br />

3VA9137-0FK31 7-83<br />

3VA9137-0FK33 7-83<br />

3VA9137-0FK35 7-83<br />

3VA9137-0FK37 7-83<br />

3VA9137-0GA80 7-85<br />

3VA9137-0GC01 7-83<br />

3VA9137-0GC05 7-83<br />

3VA9137-0GK00 7-84<br />

3VA9137-0HA10 7-87<br />

3VA9137-0HA20 7-87<br />

3VA9137-0LF10 7-104<br />

3VA9137-0PK11 7-83<br />

3VA9137-0PK13 7-83<br />

3VA9137-0PK15 7-83<br />

3VA9137-0PK17 7-83<br />

3VA9137-0PK51 7-83<br />

3VA9137-0PK53 7-83<br />

3VA9137-0PK55 7-83<br />

3VA9137-0PK57 7-83<br />

3VA9137-0VF10 7-104<br />

3VA9138-0DK72 7-86<br />

3VA9138-0DK82 7-86<br />

3VA9138-0DK84 7-86<br />

3VA9138-0LB11 11-65, 7-104<br />

3VA9138-0VF30 7-104<br />

3VA9138-0VK20 7-105<br />

3VA9143-0JA12 7-54, 7-62, 7-88<br />

3VA9143-0JB11 11-65, 7-54, 7-62, 7-88<br />

3VA9143-0JD11 11-65, 7-54, 7-62, 7-91<br />

3VA9143-0JG11 11-59, 7-54, 7-62, 7-88<br />

3VA9143-0JH12 7-62, 7-88<br />

3VA9143-0JK11 11-59, 7-54, 7-62, 7-91<br />

3VA9143-0KB01 7-98<br />

3VA9143-0KD00 7-97<br />

3VA9143-0KD10 7-97<br />

3VA9143-0KP00 7-97<br />

3VA9143-0KP10 7-97<br />

3VA9143-0SB10 7-105<br />

3VA9143-0SB20 7-105<br />

3VA9144-0JA12 7-54, 7-62, 7-88<br />

3VA9144-0JB11 7-54, 7-62, 7-88<br />

3VA9144-0JD11 7-54, 7-62, 7-91<br />

3VA9144-0JG11 7-54, 7-62, 7-88<br />

3VA9144-0JH12 7-62, 7-88<br />

3VA9144-0JK11 7-54, 7-62, 7-91<br />

3VA9144-0KB01 7-98<br />

3VA9144-0KD00 7-97<br />

3VA9144-0KD10 7-97<br />

3VA9144-0KP00 7-97<br />

3VA9144-0KP10 7-97<br />

3VA9144-0SB10 7-105<br />

3VA9144-0SB20 7-105<br />

3VA9147-0KT00 7-98<br />

3VA9147-0LF10 7-104<br />

3VA9147-0VF10 7-104<br />

3VA9148-0VF30 7-104<br />

3VA9151-0SS00 7-106<br />

3VA9151-0SS10 7-106<br />

3VA9154-0SS00 7-106<br />

3VA9156-0SS00 7-106<br />

3VA9164-0SS00 7-106<br />

3VA9166-0SS00 7-106<br />

3VA9167-0KB02 7-98<br />

3VA9177-0NA10 11-59, 7-102<br />

3VA9177-0TB10 11-59, 11-65, 7-101<br />

3VA9177-0TB50 7-101<br />

3VA9177-0VF40 7-83<br />

3VA9187-0TB60 7-101<br />

3VA9231-0QE10 7-94<br />

3VA9231-0QE20 7-94<br />

3VA9231-0QF10 7-94<br />

3VA9231-0QF20 7-94<br />

3VA9233-0JA11 7-59, 7-88<br />

3VA9233-0JA12 7-59, 7-88<br />

3VA9233-0JB11 7-59, 7-88<br />

3VA9233-0JB12 11-65, 7-59, 7-88<br />

3VA9233-0JC13 7-59, 7-89<br />

3VA9233-0JC18 7-89<br />

3VA9233-0JC22 7-90<br />

3VA9233-0JC28 7-90<br />

3VA9233-0JD11 7-59, 7-91<br />

3VA9233-0JD12 11-65, 7-59, 7-91<br />

3VA9233-0JF60 7-59, 7-90<br />

3VA9233-0JF68 7-90<br />

3VA9233-0JG11 7-59, 7-88<br />

3VA9233-0JG12 11-59, 7-59, 7-88<br />

3VA9233-0JH11 7-88<br />

3VA9233-0JH12 7-88<br />

3VA9233-0JJ13 7-59, 7-89<br />

3VA9233-0JJ22 7-59, 7-89<br />

3VA9233-0JK11 7-59, 7-91<br />

3VA9233-0JK12 11-59, 7-59, 7-91<br />

3VA9233-0QA00 7-92<br />

3VA9233-0QE00 7-94<br />

3VA9233-0QF00 7-94<br />

3VA9233-0SB20 7-105<br />

3VA9234-0JA11 7-59, 7-88<br />

3VA9234-0JA12 7-59, 7-88<br />

3VA9234-0JB11 7-59, 7-88<br />

3VA9234-0JB12 7-59, 7-88<br />

3VA9234-0JC13 7-59, 7-89<br />

3VA9234-0JC22 7-90<br />

3VA9234-0JD11 7-59, 7-91<br />

3VA9234-0JD12 7-59, 7-91<br />

3VA9234-0JF60 7-59, 7-90<br />

3VA9234-0JG11 7-59, 7-88<br />

3VA9234-0JG12 7-59, 7-88<br />

3VA9234-0JH11 7-88<br />

3VA9234-0JH12 7-88<br />

3VA9234-0JJ13 7-59, 7-89<br />

3VA9234-0JJ22 7-59, 7-89<br />

3VA9234-0JK11 7-59, 7-91<br />

3VA9234-0JK12 7-59, 7-91<br />

3VA9234-0QA00 7-92<br />

3VA9234-0QE00 7-94<br />

3VA9234-0QF00 7-94<br />

3VA9234-0SB20 7-105<br />

3VA9237-0LF10 7-104<br />

3VA9237-0SB30 7-105<br />

3VA9237-0VF10 7-104<br />

3VA9238-0VF30 7-104<br />

3VA9238-0VK20 7-105<br />

3VA9241-0QE10 7-94<br />

3VA9241-0QE20 7-94<br />

3VA9241-0QF10 7-94<br />

3VA9241-0QF20 7-94<br />

3VA9243-0JA12 7-54, 7-62, 7-88<br />

3VA9243-0JB12 11-57, 11-65, 7-54,<br />

7-62, 7-88<br />

3VA9243-0JC13 7-54, 7-62, 7-89<br />

3VA9243-0JC18 7-89<br />

3VA9243-0JC22 7-54, 7-62, 7-90<br />

3VA9243-0JC28 7-90<br />

3VA9243-0JD12 11-57, 11-65, 7-54,<br />

7-62, 7-91<br />

3VA9243-0JF60 7-54, 7-62, 7-90<br />

3VA9243-0JF68 7-90<br />

3VA9243-0JG12 11-59, 7-54, 7-62, 7-88<br />

3VA9243-0JH12 7-62, 7-88<br />

3VA9243-0JJ13 7-54, 7-62, 7-89<br />

3VA9243-0JJ22 7-54, 7-62, 7-89<br />

3VA9243-0JK12 11-59, 7-54, 7-62, 7-91<br />

3VA9243-0QA00 7-92<br />

3VA9243-0QE00 7-94<br />

3VA9243-0QF00 7-94<br />

3VA9244-0JA12 7-54, 7-62, 7-88<br />

3VA9244-0JB12 7-54, 7-62, 7-88<br />

3VA9244-0JC13 7-54, 7-62, 7-89<br />

3VA9244-0JC22 7-54, 7-62, 7-90<br />

3VA9244-0JD12 7-54, 7-62, 7-91<br />

3VA9244-0JF60 7-54, 7-62, 7-90<br />

3VA9244-0JG12 7-54, 7-62, 7-88<br />

3VA9244-0JH12 7-62, 7-88<br />

3VA9244-0JJ13 7-54, 7-62, 7-89<br />

3VA9244-0JJ22 7-54, 7-62, 7-89<br />

3VA9244-0JK12 7-54, 7-62, 7-91<br />

3VA9244-0QA00 7-92<br />

3VA9244-0QE00 7-94<br />

3VA9244-0QF00 7-94<br />

3VA9248-0VK20 7-105<br />

3VA9267-0KD81 7-98<br />

3VA9267-0KP81 7-98<br />

3VA9270-0WC00 7-96<br />

3VA9271-0WD30 7-95<br />

3VA9271-0WD31 7-95<br />

3VA9271-0WD40 7-95<br />

3VA9271-0WF30 7-95<br />

3VA9271-0WF31 7-95<br />

3VA9271-0WF40 7-95<br />

3VA9271-0WJ30 7-96<br />

3VA9271-0WJ40 7-96<br />

3VA9272-0WA00 7-95<br />

3VA9273-0QB00 7-93<br />

3VA9274-0QB00 7-93<br />

3VA9277-0CB10 7-87<br />

3VA9277-0CK12 7-87<br />

3VA9277-0CK72 7-87<br />

3VA9277-0EK11 7-82<br />

3VA9277-0EK13 7-82<br />

3VA9277-0EK15 7-82<br />

3VA9277-0EK17 7-82<br />

3VA9277-0EK21 7-82<br />

3VA9277-0EK23 7-82<br />

3VA9277-0EK25 7-82<br />

3VA9277-0EK27 7-82<br />

3VA9277-0EK31 7-82<br />

3VA9277-0EK33 7-82<br />

3VA9277-0EK35 7-82<br />

3VA9277-0EK37 7-82<br />

3VA9277-0FK21 7-83<br />

3VA9277-0FK23 7-83<br />

3VA9277-0FK25 7-83<br />

3VA9277-0FK27 7-83<br />

3VA9277-0FK31 7-83<br />

3VA9277-0FK33 7-83<br />

3VA9277-0FK35 7-83<br />

3VA9277-0FK37 7-83<br />

3VA9277-0GK00 7-84<br />

3VA9277-0HA10 11-65, 11-69, 7-87<br />

3VA9277-0HA20 11-65, 11-69, 7-87<br />

3VA9277-0HC10 7-87<br />

3VA9277-0HC15 7-87<br />

3VA9277-0HC20 7-87<br />

3VA9277-0HC30 7-87<br />

3VA9277-0HC35 7-87<br />

3VA9277-0PK11 7-83<br />

3VA9277-0PK13 7-83<br />

3VA9277-0PK15 7-83<br />

3VA9277-0PK17 7-83<br />

3VA9277-0PK51 7-83<br />

3VA9277-0PK53 7-83<br />

3VA9277-0PK55 7-83<br />

3VA9277-0PK57 7-83<br />

3VA9277-0VF40 7-83<br />

3VA9278-0CC10 7-87<br />

3VA9278-0CC20 7-87<br />

3VA9278-0CC30 7-87<br />

3VA9278-0CC40 7-87<br />

3VA9278-0CC50 7-87<br />

3VA9278-0CC60 7-87<br />

3VA9278-0CC70 7-87<br />

3VA9278-0CC80 7-87<br />

3VA9278-0DK72 7-86<br />

3VA9278-0DK82 7-86<br />

3VA9278-0DK84 7-86<br />

3VA9328-0SS10 7-106<br />

3VA9333-0SB20 7-105<br />

I<br />

PRODUCT<br />

INDEX<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog I-7


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

I<br />

PRODUCT<br />

INDEX<br />

3VA9338-0LB11 11-69, 7-104<br />

3VA9343-0KB01 7-98<br />

3VA9343-0KD00 7-97<br />

3VA9343-0KD10 7-97<br />

3VA9343-0KP00 7-97<br />

3VA9343-0KP10 7-97<br />

3VA9343-0SB20 7-105<br />

3VA9344-0KB01 7-98<br />

3VA9344-0KD00 7-97<br />

3VA9344-0KD10 7-97<br />

3VA9344-0KP00 7-97<br />

3VA9344-0KP10 7-97<br />

3VA9344-0SB20 7-105<br />

3VA9347-0KT00 7-98<br />

3VA9347-0LF10 11-64, 11-68, 7-104<br />

3VA9347-0VF10 7-104<br />

3VA9348-0VF30 7-104<br />

3VA9367-0KB02 7-98<br />

3VA9368-0SS00 7-106<br />

3VA9373-0JB13 11-57, 11-69, 7-68,<br />

7-72, 7-88<br />

3VA9373-0JD13 11-57, 11-69, 7-68,<br />

7-72, 7-91<br />

3VA9373-0JF60 7-68, 7-72, 7-90<br />

3VA9373-0JF68 7-90<br />

3VA9373-0JG13 11-59, 7-68, 7-72, 7-88<br />

3VA9373-0JK13 11-59, 7-68, 7-72, 7-91<br />

3VA9373-0SB10 7-105<br />

3VA9374-0JB13 7-68, 7-72, 7-88<br />

3VA9374-0JD13 7-68, 7-72, 7-91<br />

3VA9374-0JF60 7-68, 7-72, 7-90<br />

3VA9374-0JG13 7-68, 7-72, 7-88<br />

3VA9374-0JK13 7-68, 7-72, 7-91<br />

3VA9374-0SB10 7-105<br />

3VA9377-0NA10 11-59, 7-102<br />

3VA9377-0SB30 7-105<br />

3VA9377-0TB10 11-59, 11-69, 7-101<br />

3VA9377-0TB50 7-101<br />

3VA9378-0LB10 7-104<br />

3VA9387-0TB60 7-101<br />

3VA9443-0KD00 7-97<br />

3VA9443-0KP00 7-97<br />

3VA9444-0KD00 7-97<br />

3VA9444-0KP00 7-97<br />

3VA9447-0EK11 7-82<br />

3VA9447-0EK13 7-82<br />

3VA9447-0EK15 7-82<br />

3VA9447-0EK17 7-82<br />

3VA9447-0EK21 7-82<br />

3VA9447-0EK23 7-82<br />

3VA9447-0EK25 7-82<br />

3VA9447-0EK27 7-82<br />

3VA9447-0EK31 7-82<br />

3VA9447-0EK33 7-82<br />

3VA9447-0EK35 7-82<br />

3VA9447-0EK37 7-82<br />

3VA9447-0FK21 7-83<br />

3VA9447-0FK23 7-83<br />

3VA9447-0FK25 7-83<br />

3VA9473-0JC23 11-59, 7-68, 7-72, 7-90<br />

3VA9473-0JC28 7-90<br />

3VA9473-0JE23 11-69, 7-68, 7-72, 7-92<br />

3VA9473-0JH13 7-68, 7-72, 7-88<br />

3VA9473-0JJ23 11-69, 7-68, 7-72, 7-89<br />

3VA9473-0JL23 7-68, 7-72<br />

3VA9473-0QA00 7-92<br />

3VA9473-0QB00 7-93<br />

3VA9473-0QC00 7-93<br />

3VA9473-0QE00 7-94<br />

3VA9473-0QF00 7-94<br />

3VA9474-0JA13 7-68, 7-72, 7-88<br />

3VA9474-0JC23 7-68, 7-72, 7-90<br />

3VA9474-0JE23 7-68, 7-72, 7-92<br />

3VA9474-0JH13 7-68, 7-72, 7-88<br />

3VA9474-0JJ23 7-68, 7-72, 7-89<br />

3VA9474-0JL23 7-68, 7-72<br />

3VA9474-0QA00 7-92<br />

3VA9474-0QB00 7-93<br />

3VA9474-0QC00 7-93<br />

3VA9474-0QE00 7-94<br />

3VA9474-0QF00 7-94<br />

3VA9477-0CB10 7-87<br />

3VA9477-0CK12 7-87<br />

3VA9477-0CK72 7-87<br />

3VA9477-0FH11 7-85<br />

3VA9477-0FH15 7-85<br />

3VA9477-0GA80 7-85<br />

3VA9477-0GC01 7-83<br />

3VA9477-0GC05 7-83<br />

3VA9477-0GC11 7-83<br />

3VA9477-0GC15 7-83<br />

3VA9477-0GF10 7-85<br />

3VA9477-0GF11 7-85<br />

3VA9477-0GF20 7-85<br />

3VA9477-0GF21 7-85<br />

3VA9478-0CX10 7-87<br />

3VA9478-0CX20 7-87<br />

3VA9478-0DK72 7-86<br />

3VA9478-0DK82 7-86<br />

3VA9478-0DK84 7-86<br />

3VA9487-0GB10 7-85<br />

3VA9487-0SC10 7-106<br />

3VA9573-0JB23 7-76, 7-88<br />

3VA9573-0JG23 7-76<br />

3VA9574-0JB23 7-76, 7-89<br />

3VA9574-0JG23 7-76<br />

3VA9577-0LF10 7-104<br />

3VA9577-0VF10 7-104<br />

3VA9578-0CC10 7-87<br />

3VA9578-0CC20 7-87<br />

3VA9578-0CC30 7-87<br />

3VA9578-0CC40 7-87<br />

3VA9578-0CC50 7-87<br />

3VA9578-0CC60 7-87<br />

3VA9578-0CC70 7-87<br />

3VA9578-0CC80 7-87<br />

3VA9578-0LB10 7-104<br />

3VA9578-0VM10 7-104<br />

3VA9583-0SB10 7-105<br />

3VA9673-0QE00 7-94<br />

3VA9674-0JB32 7-76, 7-89<br />

3VA9674-0JC24 7-76, 7-90<br />

3VA9674-0JC34 7-76, 7-90<br />

3VA9674-0JC43 7-76, 7-90<br />

3VA9674-0JC44 7-76, 7-90<br />

3VA9674-0JD32 7-76, 7-91<br />

3VA9674-0JE43 7-76, 7-92<br />

3VA9674-0JG23 7-89<br />

3VA9674-0JG32 7-76, 7-89<br />

3VA9674-0JJ24 7-76, 7-90<br />

3VA9674-0JJ34 7-76, 7-90<br />

3VA9674-0JJ43 7-76, 7-90<br />

3VA9674-0JJ44 7-76, 7-90<br />

3VA9674-0JK32 7-76, 7-91<br />

3VA9674-0JL43 7-76, 7-92<br />

3VA9674-0QA00 7-92<br />

3VA9674-0QB00 7-93<br />

3VA9674-0QC00 7-93<br />

3VA9674-0QE00 7-94<br />

3VA9677-0EK11 7-82<br />

3VA9677-0EK15 7-82<br />

3VA9677-0EK21 7-82<br />

3VA9677-0EK25 7-82<br />

3VA9677-0EK31 7-82<br />

3VA9677-0EK35 7-82<br />

3VA9677-0FK21 7-83<br />

3VA9677-0FK23 7-83<br />

3VA9677-0FK25 7-83<br />

3VA9677-0FK27 7-83<br />

3VA9677-0FK31 7-83<br />

3VA9677-0FK33 7-83<br />

3VA9677-0FK35 7-83<br />

3VA9677-0FK37 7-83<br />

3VA9677-0GA80 7-85<br />

3VA9677-0GC01 7-83<br />

3VA9677-0GC05 7-83<br />

3VA9677-0GK00 7-84<br />

3VA9677-0NA10 7-102<br />

3VA9877-0GF22 7-85<br />

3VA9877-0GF23 7-85<br />

3VA9970-0LF40 7-99<br />

3VA9977-0CH12 7-87<br />

3VA9977-0CH72 7-87<br />

3VA9977-0CH74 7-87<br />

3VA9977-0CH82 7-87<br />

3VA9977-0CH84 7-87<br />

3VA9977-0KB00 7-99<br />

3VA9977-0KC00 7-99<br />

3VA9977-0KD80 7-99<br />

3VA9977-0KP80 7-99<br />

3VA9977-0MA10 11-59, 7-103<br />

3VA9977-0MB10 11-59, 7-103<br />

3VA9977-0MY10 11-59, 7-103<br />

3VA9977-0TA10 11-59, 7-101<br />

3VA9977-0TA20 11-59, 7-101<br />

3VA9977-0TD10 11-59, 7-102<br />

3VA9977-0UA10 11-59, 7-102<br />

3VA9977-0UF10 11-59, 7-103<br />

3VA9978-0BA25 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0BB10 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0BB11 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0BB12 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0BB14 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0BB16 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0BB20 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0BB24 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0BB25 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0BB27 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0BD11 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0BD12 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0BD13 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0BF22 7-81<br />

3VA9978-0BF23 7-81<br />

3VA9978-0BL10 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0BL20 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0BL30 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0BL31 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0BL32 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0BL33 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9980-0LF20 7-86<br />

3VA9980-0VC10 7-105<br />

3VA9980-0VC20 7-105<br />

3VA9980-0VC30 7-105<br />

3VA9980-0VL10 11-64, 11-68,<br />

7-104, 7-86, 7-99<br />

3VA9980-0VL20 11-64, 11-68<br />

3VA9980-0VL30 11-64, 11-68,<br />

7-104, 7-86, 7-99<br />

3VA9980-0VL40 11-64, 11-68,<br />

7-104, 7-86, 7-99<br />

3VA9987-0KC10 7-99<br />

3VA9987-0KD81 7-98<br />

3VA9987-0MX10 11-59, 7-103<br />

3VA9987-0TC10 11-59, 7-102<br />

3VA9987-0TC20 11-59, 7-102<br />

3VA9987-0TC30 11-59, 7-102<br />

3VA9987-0TC40 11-59, 7-102<br />

3VA9987-0TE10 11-59, 7-102<br />

3VAE60012 6-13, 7-68, 7-72<br />

3VAE6001F 6-9, 7-68, 7-72<br />

3VAE6001S 6-9, 7-68, 7-72<br />

3VAE6003R 6-11, 7-68, 7-72<br />

3VAE6004X 7-68, 7-72<br />

3VAE6004X316 7-68, 7-72<br />

3VAE80012 6-13<br />

3VAE8001F 6-9<br />

3VAE8001S 6-9<br />

3VAE8003R 6-11<br />

3VAE8004X 6-12<br />

3VAE8004X316 6-12<br />

3VL97008BL00 7-214, 7-215<br />

3ZS27102CC200YH0 9-26<br />

3ZS27103CC000YD0 9-26<br />

3ZS27110CC300YA0 9-26<br />

3ZS27110CC300YD0 9-26<br />

3ZS27118CC300YA0 9-26<br />

3ZS27120CC300YD0 9-26<br />

3ZS27130CC300YD0 9-26<br />

3ZS27140CC300YD0 9-26<br />

3ZS27150CC300YD0 9-26<br />

3ZS27160CC300YD0 9-26<br />

3ZS27181CC000YH0 9-26<br />

3ZS27182CC000YH0 9-26<br />

3ZS27183CC000YH0 9-26<br />

3ZS67100CC900BA0 9-27<br />

3ZS67100CC900BC0 9-27<br />

3ZS67220CC900BA2 9-27<br />

3ZS67230CC900BA2 9-27<br />

3ZS67317CC900BA0 9-27<br />

3ZS67420CC900BA2 9-27<br />

3ZS67520CC900BA2 9-27<br />

3ZS68120CC900BA2 9-27<br />

3ZS68130CC900BA2 9-27<br />

3ZS68140CC900BA2 9-27<br />

3ZS68220CC900BA2 9-27<br />

3ZS68230CC900BA2 9-27<br />

3ZS68240CC900BA2 9-27<br />

40 Series NEMA Contactors<br />

17-51, 17-52<br />

400-5000A 13-13<br />

40007-01GP 2-9<br />

40404-02QG 2-9<br />

40405-015F 2-9<br />

40405-025 2-9<br />

40405-02CO 2-9<br />

40405-02GP 2-9<br />

40405-02QG 2-9<br />

40405-0BNU 2-9<br />

40405P-9WI 2-12<br />

40407-015F 2-9<br />

40407-01NU 2-9<br />

40407-025 2-9<br />

40407-02CO 2-9<br />

40407-02GP 2-9<br />

40407-02QG 2-9<br />

40407P-9CH 2-12<br />

40407P-9UE 2-12<br />

3VA9447-0FK27 7-83<br />

3VA9447-0FK31 7-83<br />

3VA9447-0FK33 7-83<br />

3VA9447-0FK35 7-83<br />

3VA9447-0FK37 7-83<br />

3VA9447-0GK00 7-84<br />

3VA9447-0HA10 11-59, 7-87<br />

3VA9447-0HA20 7-87<br />

3VA9448-0VK20 7-105<br />

3VA9457-0KD81 7-98<br />

3VA9583-0SB20 7-105<br />

3VA9583-0SB50 7-105<br />

3VA9584-0SB10 7-105<br />

3VA9584-0SB20 7-105<br />

3VA9670-0LF20 7-86<br />

3VA9671-0WD30 7-95<br />

3VA9671-0WD40 7-95<br />

3VA9671-0WE30 7-95<br />

3VA9671-0WE40 7-95<br />

3VA9671-0WF30 7-95<br />

3VA9978-0AA11 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0AA12 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0AA13 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0AA21 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0AA22 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9987-0TF10 11-59, 11-65,<br />

11-69, 7-102<br />

3VA9987-0TF20 11-59, 11-65,<br />

11-69, 7-102<br />

3VA9987-0TG10 11-59, 11-65,<br />

11-69, 7-102<br />

3VA9987-0TG11 7-102<br />

3VA9987-0UB10 7-102<br />

3VA9987-0UB20 7-102<br />

3VA9987-0UB30 7-102<br />

40407P-9WI 2-12<br />

42 & 45 Definite Purpose Control<br />

17-54, 17-55, 17-56, 17-57, 17-58<br />

42505-02RG 2-9<br />

42NLK18 11-11, 11-22<br />

42NLK30 11-11, 11-22<br />

42NLK30A 11-11, 11-22<br />

42NLK42 11-11, 11-22<br />

42NLK42A 11-11, 11-22<br />

42NLK54A 11-11, 11-22<br />

3VA9457-0KP81 7-98<br />

3VA9470-0WC00 7-96<br />

3VA9471-0QE10 7-94<br />

3VA9471-0QE20 7-94<br />

3VA9471-0QF10 7-94<br />

3VA9471-0QF20 7-94<br />

3VA9471-0WD30 7-95<br />

3VA9471-0WD31 7-95<br />

3VA9471-0WD40 7-95<br />

3VA9471-0WF30 7-95<br />

3VA9671-0WF40 7-95<br />

3VA9672-0WA00 7-95<br />

3VA9673-0JB32 7-76, 7-89<br />

3VA9673-0JC24 7-76, 7-90<br />

3VA9673-0JC34 7-76, 7-90<br />

3VA9673-0JC43 7-76, 7-90<br />

3VA9673-0JC44 7-76, 7-90<br />

3VA9673-0JD32 7-76, 7-91<br />

3VA9673-0JE43 7-76, 7-92<br />

3VA9673-0JG23 7-89<br />

3VA9978-0AA23 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0AB11 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0AB12 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0AB13 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0AB22 11-64, 11-68, 7-81<br />

3VA9978-0AB23 11-64, 11-68, 7-81<br />

3VA9987-0UC10 7-102<br />

3VA9987-UB10 11-59<br />

3VA9987-UB20 11-59<br />

3VAE125N12 6-13, 7-49<br />

3VAE125N1F 6-9, 7-49<br />

3VAE125N1S 6-9, 7-49<br />

3VAE125N3R 6-11, 7-49<br />

3VAE125N4X 6-12, 7-49<br />

3VAE125N4X316 6-12, 7-49<br />

43 Series NEMA Reversing<br />

Contactors 17-53<br />

44305-02CV 2-9<br />

44307-02CV 2-9<br />

44704-8265 2-10<br />

47604-81GP 2-10<br />

47604P-9CH 2-12<br />

47604P-9WI 2-12<br />

47604PB-9CH 2-12<br />

47605-02SP 2-10<br />

3VA9471-0WF31 7-95<br />

3VA9471-0WF40 7-95<br />

3VA9471-0WG30 7-95<br />

3VA9471-0WG40 7-95<br />

3VA9471-0WJ30 7-96<br />

3VA9471-0WJ40 7-96<br />

3VA9471-0WK30 7-96<br />

3VA9471-0WK40 7-96<br />

3VA9472-0WA00 7-95<br />

3VA9473-0JA13 7-68, 7-72, 7-88<br />

3VA9673-0JG32 7-76, 7-89<br />

3VA9673-0JJ24 7-76, 7-90<br />

3VA9673-0JJ34 7-76, 7-90<br />

3VA9673-0JJ43 7-76, 7-90<br />

3VA9673-0JJ44 7-76, 7-90<br />

3VA9673-0JK32 7-76, 7-91<br />

3VA9673-0JL43 7-76, 7-92<br />

3VA9673-0QA00 7-92<br />

3VA9673-0QB00 7-93<br />

3VA9673-0QC00 7-93<br />

3VA9978-0BA20 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0BA21 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0BA22 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0BA23 11-62, 11-64,<br />

11-68, 7-81<br />

3VA9978-0BA24 11-62, 11-64,<br />

11-68, 7-81<br />

3VAE250N12 6-13, 7-54, 7-56,<br />

7-57, 7-62<br />

3VAE250N1F 6-9, 7-54, 7-56, 7-57, 7-62<br />

3VAE250N1S 6-9, 7-54, 7-56, 7-57, 7-62<br />

3VAE250N3R 6-11, 7-54,<br />

7-56, 7-57, 7-62<br />

3VAE250N4X 6-12, 7-54,<br />

7-56, 7-57, 7-62<br />

3VAE250N4X316 6-12, 7-54,<br />

7-56, 7-57, 7-62<br />

47704-01NU 2-10<br />

47704-02 2-10<br />

47705-01NU 2-10<br />

47707-01NU 2-10<br />

47707-02 2-10<br />

48 Series NEMA Overload Relays<br />

17-64<br />

48104-02 2-10<br />

48105-83BU 2-10<br />

48504-92 2-10<br />

I-8<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

7KM9300-0AE01-0AA0 11-59, 7-101<br />

7KM9300-0AM00-0AA0 11-59, 7-101<br />

7KM93000AB010AA0 9-7, 9-8<br />

7KM93000AE020AA0 9-7, 9-8<br />

7KM9900-0XA00-0AA0 9-5<br />

7KM9900-0YA00-0AA0 9-5<br />

7KM99000XA000AA0 9-7, 9-8<br />

7KM99000YA000AA0 9-7, 9-8<br />

7KT1280-5MA00 9-14, 9-16<br />

7KT1280-5MA01 9-14, 9-16<br />

7KT1280-5MA02 9-14, 9-16<br />

7KT1280-5MA03 9-14, 9-16<br />

7KT1280-5MA04 9-14, 9-16<br />

7KT1280-5MA05 9-14, 9-16<br />

7KT1280-5MA06 9-14, 9-16<br />

7KT1280-5MA07 9-14, 9-16<br />

7KT1280-5MA08 9-14, 9-16<br />

83 Series Non Combination Duplex<br />

Controller 17-67<br />

I<br />

PRODUCT<br />

INDEX<br />

48704-82GP 2-10<br />

48707-82GP 2-10<br />

48805-0BNU 2-9<br />

48807-02NU 2-9<br />

49 Series Field Kits 17-102, 17-103<br />

4MLKA1 11-11, 11-22<br />

4MLKA1A 11-11, 11-22<br />

4MLKA1B 11-11, 11-22<br />

4MLKA3 11-11, 11-22<br />

4MLKA3A 11-11, 11-22<br />

4MLKA3B 11-11, 11-22<br />

4MLKC1 11-11, 11-22<br />

4MLKC1A 11-11, 11-22<br />

4MLKC3 11-11, 11-22<br />

4MLKC3A 11-11, 11-22<br />

505BB1224J 8-22<br />

505BB1632J 8-23<br />

505BB2448J 8-24<br />

52 Series Momentary Push Button,<br />

Non-Illuminated 17-300, 17-301<br />

52 Series Push-Pull Mushroom,<br />

Non-Illuminated 17-302, 17-303<br />

52 Series Push-Pull Mushroom,<br />

Illuminated 17-304, 17-305<br />

52 Series Twist-to-Release,<br />

Mushroom, Non-Illuminated 17-306<br />

52 Series Twist-to-Release,<br />

Mushroom, Illuminated 17-307<br />

52 Series Indicator Light<br />

17-308, 17-309<br />

52 Series Push Button & Push-to-<br />

Test, Illuminated 17-310, 17-311<br />

52 Series Push Button Mushroom,<br />

Illuminated 17-312<br />

52 Series Selector Switches,<br />

Illuminated 17-313<br />

52 Series Switch Short & Long Lever,<br />

Non-Illuminated 17-314, 17-315<br />

52 Series Keyed Selector Switch<br />

17-316, 17-317<br />

52 Series Push Button 17-319<br />

5BB1224J 8-22<br />

5BB1632J 8-23<br />

5BB2448J 8-24<br />

64690-1 2-25<br />

6CLE2 13-25<br />

6CLF1 13-25<br />

6CLJ1 13-25<br />

6CLL1 13-25<br />

6CLL350 7-187, 7-213<br />

6CLL600 7-187, 7-213<br />

6E62 13-25<br />

6F62 13-25<br />

6FPB01 11-77, 11-91, 13-26<br />

6FPB02 11-77, 11-91, 13-26<br />

6FPB03 11-77, 11-91, 13-26<br />

6FPB05 11-77, 11-91, 13-26<br />

6FPB10 11-77, 11-91, 13-26<br />

6JJ61 13-25<br />

6JJ62 13-25<br />

6LL61 13-25<br />

6QJ2 13-25<br />

6QR2 13-25<br />

6SCJ1 13-25<br />

6SCL1 13-25<br />

6SJL1 13-25<br />

6SLL1 13-25<br />

705BB1224J 8-22<br />

705BB1632J 8-23<br />

705BB2448J 8-24<br />

73 Series Enclosed Soft Starters<br />

17-224, 17-225, 17-230, 17-231<br />

74 Series Enclosed Soft Starters<br />

17-226, 17-227, 17-228, 17-229,<br />

17-232, 17-233, 17-234, 17-235<br />

75 Series Kits 17-122, 17-123<br />

7KM22002EA301DA1 9-4<br />

7KM22002EA301EA1 9-4<br />

7KM22002EA301HA1 9-4<br />

7KM22002EA301JA1 9-4<br />

7KM31200BA011DA0 9-5<br />

7KM31201BA011EA0 9-5<br />

7KM32000CA011AA0 9-6<br />

7KM32200BA011DA0 9-7<br />

7KM32201BA011EA0 9-7<br />

7KM42111BA003AA0 9-8<br />

7KM42120BA003AA0 9-8<br />

7KM92000AB000AA0 9-8<br />

7KM92000AD000AA0 9-7, 9-8<br />

7KM9300-0AB01-0AA0 11-59, 7-101<br />

84 Series Combination Duplex<br />

Controller 17-68, 17-69<br />

87 Series Pump Control Panels<br />

17-76, 17-77<br />

88 Series Pump Control Panels<br />

17-78, 17-79<br />

8UD1721-0AB11 7-84<br />

8UD1721-0AB15 7-84<br />

8UD1721-0AB21 7-84<br />

8UD1721-0AB25 7-84<br />

8UD1721-0AC11 7-84<br />

8UD1721-0AC15 7-84<br />

8UD1721-0AC21 7-84<br />

8UD1721-0AC25 7-84<br />

8UD1731-0AB11 7-84<br />

8UD1731-0AB15 7-84<br />

8UD1731-0AB21 7-84<br />

8UD1731-0AB25 7-84<br />

8UD1731-0AC11 7-84<br />

8UD1731-0AC15 7-84<br />

8UD1731-0AC21 7-84<br />

8UD1731-0AC25 7-84<br />

8UD1741-0AB11 7-84<br />

8UD1741-0AB15 7-84<br />

8UD1741-0AB21 7-84<br />

8UD1741-0AB25 7-84<br />

8UD1900-0KA10 7-86<br />

8UD1900-0KA20 7-86<br />

8UD1900-0KA30 7-86<br />

8UD1900-0MB01 7-86<br />

8UD1900-0MB05 7-86<br />

8UD1900-0MC01 7-86<br />

8UD1900-0MC05 7-86<br />

8UD1900-0NB01 7-86<br />

8UD1900-0NB05 7-86<br />

8UD1900-0NC01 7-86<br />

8UD1900-0NC05 7-86<br />

8UD1900-0PB01 7-86<br />

8UD1900-0PB05 7-86<br />

8UD1900-0PC01 7-86<br />

8UD1900-0PC05 7-86<br />

8UD1900-0QB01 7-86<br />

8UD1900-0QB05 7-86<br />

8UD1900-0QC01 7-86<br />

8UD1900-0QC05 7-86<br />

8UD1900-2DA00 7-85<br />

8UD1900-2GA00 7-85<br />

8UD1900-2HA00 7-85<br />

8UD1900-2WA00 7-85<br />

8UD1900-2WB00 7-85<br />

8UD1900-4DA00 7-85<br />

8UD1900-4GA00 7-85<br />

8UD1900-4HA00 7-85<br />

8UD1900-4WA00 7-85<br />

8UD1900-4WB00 7-85<br />

8US1211-4SS00 7-106<br />

8US1213-4AH04 7-106<br />

8US1213-4AP03 7-106<br />

8US1215-4SS00 7-106<br />

93-47ADAPTER 9-5, 9-7, 9-8<br />

958 Series NEMA Overload Relays<br />

17-66, 17-67, 17-69<br />

9804-8419 2-23<br />

9804-8420 2-23<br />

9804-8422 2-23<br />

9804-8423 2-23<br />

9804-8426 2-23<br />

9804-8456 2-23<br />

9804-8457 2-23<br />

9804-8459 2-23<br />

9804-8460 2-23<br />

9804-8463 2-23<br />

9804-8482 2-23<br />

9804-8483 2-23<br />

9804-8485 2-23<br />

9804-8486 2-23<br />

9804-8542 2-23<br />

9804-8543 2-23<br />

9804-8544 2-23<br />

9804-8546 2-23<br />

9804-8547 2-23<br />

9804-8548 2-23<br />

9804-9142 2-9<br />

9804-9144 2-10<br />

9804-9145 2-10<br />

9804-9146 2-10<br />

9804-9147 2-10<br />

9817-8061 2-10<br />

9817-9504 2-10<br />

9837-8200 2-22<br />

9837-8201 2-22<br />

9837-8202 2-22<br />

9837-8203 2-22<br />

9837-8204 2-22<br />

9837-8205 2-22<br />

9837-8210 2-22<br />

9837-8211 2-22<br />

9837-8212 2-22<br />

9837-8213 2-22<br />

9837-8214 2-22<br />

9837-8215 2-22<br />

9837-8220 2-22<br />

9837-8221 2-22<br />

9837-8222 2-22<br />

9837-8223 2-22<br />

9837-8224 2-22<br />

9837-8225 2-22<br />

9837-8230 2-22<br />

9837-8231 2-22<br />

9837-8232 2-22<br />

9837-8233 2-22<br />

9837-8234 2-22<br />

9837-8235 2-22<br />

9837-8240 2-22<br />

9837-8241 2-22<br />

9837-8242 2-22<br />

9837-8243 2-22<br />

9837-8244 2-22<br />

9837-8245 2-22<br />

9837-8400 2-22<br />

9837-8401 2-22<br />

9837-8402 2-22<br />

9837-8403 2-22<br />

9837-8404 2-22<br />

9837-8405 2-22<br />

9837-8410 2-22<br />

9837-8411 2-22<br />

9837-8412 2-22<br />

9837-8413 2-22<br />

9837-8414 2-22<br />

9837-8415 2-22<br />

9837-8420 2-22<br />

9837-8421 2-22<br />

9837-8422 2-22<br />

9837-8423 2-22<br />

9837-8424 2-22<br />

9837-8425 2-22<br />

9837-8430 2-22<br />

9837-8431 2-22<br />

9837-8432 2-22<br />

9837-8433 2-22<br />

9837-8434 2-22<br />

9837-8435 2-22<br />

9837-8440 2-22<br />

9837-8441 2-22<br />

9837-8442 2-22<br />

9837-8443 2-22<br />

9837-8444 2-22<br />

9837-8445 2-22<br />

9837-8500 2-22<br />

9837-8501 2-22<br />

9837-8502 2-22<br />

9837-8503 2-22<br />

9837-8504 2-22<br />

9837-8505 2-22<br />

9837-8510 2-22<br />

9837-8511 2-22<br />

9837-8512 2-22<br />

9837-8513 2-22<br />

9837-8514 2-22<br />

9837-8515 2-22<br />

9837-8520 2-22<br />

9837-8521 2-22<br />

9837-8522 2-22<br />

9837-8523 2-22<br />

9837-8524 2-22<br />

9837-8525 2-22<br />

9837-8530 2-22<br />

9837-8531 2-22<br />

9837-8532 2-22<br />

9837-8533 2-22<br />

9837-8534 2-22<br />

9837-8535 2-22<br />

9837-8540 2-22<br />

9837-8541 2-22<br />

9837-8542 2-22<br />

9837-8543 2-22<br />

9837-8544 2-22<br />

A01ED62 7-113<br />

A01ED62B 7-113<br />

A01ED64 7-113<br />

A01ED64B 7-113<br />

A01EDLV 7-113<br />

A01FD62 7-116<br />

A01FD64 7-116<br />

A01FDLV 7-116<br />

A01HCPL4 5-27<br />

A01HCPR4 5-27<br />

A01JLD64 7-120, 7-124, 7-127<br />

A01JLD64B 7-120, 7-124, 7-127<br />

A01JLDLV 7-120, 7-124, 7-127<br />

A01MN64 7-131, 7-135, 7-138<br />

A01MN64B 7-131, 7-135, 7-138<br />

A01MNDLV 7-131, 7-135, 7-138<br />

A01QR2 7-41<br />

A02ED62 7-113<br />

A02ED62B 7-113<br />

A02FD62 7-116<br />

A02FD64 7-116<br />

A02JLD64 7-120, 7-124, 7-127<br />

A02JLD64B 7-120, 7-124, 7-127<br />

A02JLDLV 7-120, 7-124, 7-127<br />

A02MN64 7-131, 7-135, 7-138<br />

A02MN64B 7-131, 7-135, 7-138<br />

A02MNDLV 7-131, 7-135, 7-138<br />

A02QR2 7-41<br />

A30H2408GQRLP 11-25<br />

A36H3008GQRLP 11-25<br />

A48H3612GQRLP 11-25<br />

A60H3612GQRLP 11-25<br />

ABD302 15-80<br />

ABD304 15-80<br />

ABD306 15-80<br />

ABD308 15-80<br />

ABD310 15-80<br />

ABD312 15-80<br />

ABD4024 15-80<br />

ABD4044 15-80<br />

ABD4064 15-80<br />

ABD4084 15-80<br />

ABD4104 15-80<br />

ABD4124 15-80<br />

AL1/0-NTN 15-19<br />

AL2/0-NTN 15-19<br />

AL250-NTN 15-19<br />

AL3/0-NTN 15-19<br />

AL300-NTN 15-19<br />

AL350-NTN 15-19<br />

AL4/0-NTN 15-19<br />

AMBL1 7-178, 7-182, 7-186, 7-190<br />

AMBL2 7-178, 7-182, 7-186, 7-190<br />

AMBL3 7-178, 7-182, 7-186, 7-190<br />

AMBP1 7-194, 7-198, 7-201<br />

AMBP2 7-194, 7-198, 7-201<br />

ANSI/NEMA 11-11, 11-23, 11-38, 11-49<br />

ASKL1 7-178, 7-182, 7-186, 7-190, 7-219<br />

ASKL2 7-178, 7-182, 7-186, 7-190, 7-219<br />

ASKL3 7-178, 7-182, 7-186, 7-190, 7-219<br />

ASKP3 7-194, 7-198, 7-201, 7-219<br />

ASKP4 7-194, 7-198, 7-201, 7-219<br />

ASL1/0-NTN 15-19<br />

ASL2/0-NTN 15-19<br />

ASL250-NTN 15-19<br />

ASL3/0-NTN 15-19<br />

ASL300-NTN 15-19<br />

ASL350-NTN 15-19<br />

ASL4/0-NTN 15-19<br />

ASWPA 7-178, 7-182, 7-186,<br />

7-190, 7-194, 7-198, 7-201<br />

ASWPB 7-178, 7-182, 7-186,<br />

7-190, 7-194, 7-198, 7-201<br />

B00ED62 7-113<br />

B00ED64 7-113<br />

B00FD64 7-116<br />

B00MN64 7-131, 7-135, 7-138<br />

B01JLD64 7-120, 7-124, 7-127<br />

B110 7-29<br />

B115 11-13, 7-29<br />

B115DF 11-14, 7-30<br />

B115DFH 11-14, 7-30<br />

B115DFHH 11-14, 7-30<br />

B115H 11-13, 7-29<br />

B115HH 11-13, 7-29<br />

B115HID 7-31<br />

B120 11-13, 7-29<br />

B120DF 11-14, 7-30<br />

B120DFH 11-14, 7-30<br />

B120DFHH 11-14, 7-30<br />

B120H 11-13, 7-29<br />

B120HH 11-13, 7-29<br />

B120HID 7-31<br />

B125 11-13, 7-29<br />

B125H 11-13, 7-29<br />

B125HH 7-29<br />

B130 11-13, 7-29<br />

B130H 11-13, 7-29<br />

B130HH 11-13, 7-29<br />

B130HID 7-31<br />

B135 11-13, 7-29<br />

B135H 11-13, 7-29<br />

B135HH 7-29<br />

B140 11-13, 7-29<br />

B140H 11-13, 7-29<br />

B140HH 11-13, 7-29<br />

B145 11-13, 7-29<br />

B145H 11-13, 7-29<br />

B145HH 7-29<br />

B150 11-13, 7-29<br />

B150H 11-13, 7-29<br />

B150HH 11-13, 7-29<br />

B155 11-13<br />

B155H 11-13<br />

B160 11-13, 7-29<br />

B160H 11-13, 7-29<br />

B160HH 7-29<br />

B170 11-13, 7-29<br />

B170H 11-13, 7-29<br />

B170HH 7-29<br />

B210 7-29<br />

B2100 11-13, 7-29<br />

B2100H 11-13, 7-29<br />

B2100HH 11-13, 7-29<br />

B2110 7-29<br />

B2110H 7-29<br />

B2110HH 7-29<br />

B2125 7-29<br />

B2125H 7-29<br />

B2125HH 7-29<br />

B215 11-13, 7-29<br />

B215AFC 11-14, 7-30<br />

B215AFCH 11-14, 7-30<br />

B215H 11-13, 7-29<br />

B215HH 11-13, 7-29<br />

B215HID 7-31<br />

B215R 11-13, 7-29<br />

B220 11-13, 7-29<br />

B220AFC 11-14, 7-30<br />

B220AFCH 11-14, 7-30<br />

B220H 11-13, 7-29<br />

B220HH 11-13, 7-29<br />

B220HID 7-31<br />

B220R 11-13, 7-29<br />

B225 11-13, 7-29<br />

B225H 11-13, 7-29<br />

B225HH 7-29<br />

B225R 11-13<br />

B230 11-13, 7-29<br />

B230H 11-13, 7-29<br />

B230HH 11-13, 7-29<br />

B230HID 7-31<br />

B230R 11-13, 7-29<br />

B230S 7-31<br />

B235 11-13, 7-29<br />

B235H 11-13, 7-29<br />

B235HH 7-29<br />

B235R 11-13<br />

B240 11-13, 7-29<br />

B240H 11-13, 7-29<br />

B240HH 11-13, 7-29<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog I-9


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

I<br />

PRODUCT<br />

INDEX<br />

B240R 11-13, 7-29<br />

B245 11-13, 7-29<br />

B245H 11-13, 7-29<br />

B245HH 7-29<br />

B245R 11-13<br />

B250 11-13, 7-29<br />

B250H 11-13, 7-29<br />

B250HH 11-13, 7-29<br />

B250R 11-13, 7-29<br />

B26 11-38<br />

B260 11-13, 7-29<br />

B260H 11-13, 7-29<br />

B260HH 11-13, 7-29<br />

B270 11-13, 7-29<br />

B270H 11-13, 7-29<br />

B270HH 11-13, 7-29<br />

B280 11-13, 7-29<br />

B280H 11-13, 7-29<br />

B280HH 11-13, 7-29<br />

B290 11-13, 7-29<br />

B290H 11-13, 7-29<br />

B290HH 11-13, 7-29<br />

B3100 11-13, 7-29<br />

B3100H 11-13, 7-29<br />

B3100HH 11-13, 7-29<br />

B315 11-13, 7-29<br />

B315H 11-13, 7-29<br />

B315HH 11-13, 7-29<br />

B32 11-38<br />

B320 11-13, 7-29<br />

B320H 11-13, 7-29<br />

B320HH 11-13, 7-29<br />

B325 11-13, 7-29<br />

B325H 11-13, 7-29<br />

B325HH 7-29<br />

B330 11-13, 7-29<br />

B330H 11-13, 7-29<br />

B330HH 11-13, 7-29<br />

B335 11-13, 7-29<br />

B335H 11-13, 7-29<br />

B335HH 7-29<br />

B340 11-13, 7-29<br />

B340H 11-13, 7-29<br />

B340HH 11-13, 7-29<br />

B345 11-13, 7-29<br />

B345H 11-13, 7-29<br />

B345HH 7-29<br />

B350 11-13, 7-29<br />

B350H 11-13, 7-29<br />

B350HH 11-13, 7-29<br />

B360 11-13, 7-29<br />

B360H 11-13, 7-29<br />

B360HH 11-13, 7-29<br />

B370 11-13, 7-29<br />

B370H 11-13, 7-29<br />

B370HH 11-13, 7-29<br />

B38 11-38<br />

B380 11-13, 7-29<br />

B380H 11-13, 7-29<br />

B380HH 11-13, 7-29<br />

B390 11-13, 7-29<br />

B390H 11-13, 7-29<br />

B390HH 11-13, 7-29<br />

B44 11-38<br />

B4X26 11-25, 11-37<br />

B4X32 11-25, 11-37<br />

B4X38 11-25, 11-37<br />

B4X44 11-25, 11-37<br />

B4X50 11-25, 11-37<br />

B4X56 11-25, 11-37<br />

B4X62 11-25, 11-37<br />

B4X68 11-25, 11-37<br />

B4X74 11-25, 11-37<br />

B50 11-38<br />

B56 11-38<br />

B62 11-38<br />

B68 11-38<br />

B74 11-38<br />

BA115AFC 11-14, 7-30<br />

BA115AFCH 11-14, 7-30<br />

BA115AFCHH 11-14, 7-30<br />

BA120AFC 11-14, 7-30<br />

BA120AFCH 11-14<br />

BA120AFCHH 11-14, 7-30<br />

BBKA52P3HW 11-49<br />

BBKB32 11-38, 11-49<br />

BBKEB32 11-49<br />

BBKED32 11-38, 11-49<br />

BBKGB32 11-38, 11-49<br />

BBKNB32 11-38, 11-49<br />

BBKQ1 11-38<br />

BBKQ2 11-49<br />

BBKQR1 11-38<br />

BBKQR2 11-49<br />

BBKQRP1FK 11-15, 11-38<br />

BBKQRP2FK 11-15, 11-49<br />

BBKVA52P3T 11-49<br />

BCT1036HND6 13-21<br />

BCT1036NXD6 13-21<br />

BCT1236HND6 13-21<br />

BCT1236NXD6 13-21<br />

BCT436HJD6 13-21<br />

BCT436JXD6 13-21<br />

BCT636HLD6 13-21<br />

BCT636LXD6 13-21<br />

BCT836HMD6 13-21<br />

BCT836MXD6 13-21<br />

BDH10 15-80<br />

BDH12 15-80<br />

BDP302 15-80<br />

BDP304 15-80<br />

BDP306 15-80<br />

BDP308 15-80<br />

BDP310 15-80<br />

BDP313 15-80<br />

BDP316 15-80<br />

BDP4024 15-80<br />

BDP4044 15-80<br />

BDP4064 15-80<br />

BDP4084 15-80<br />

BDP4104 15-80<br />

BE1 3-102<br />

BE112 3-102<br />

BE115 7-30<br />

BE1153 11-14<br />

BE115H 7-30<br />

BE115H2 11-14<br />

BE120 7-30<br />

BE1203 11-14<br />

BE120H 7-30<br />

BE120H2 11-14<br />

BE130 11-14, 7-30<br />

BE130H 7-30<br />

BE130H2 11-14<br />

BE215 11-14, 7-30<br />

BE215H 7-30<br />

BE215H2 11-14<br />

BE220 11-14, 7-30<br />

BE220H 7-30<br />

BE220H2 11-14<br />

BE230 11-14, 7-30<br />

BE230H 7-30<br />

BE230H2 11-14<br />

BE240 11-14, 7-30<br />

BE240H 7-30<br />

BE240H2 11-14<br />

BE250 11-14, 7-30<br />

BE250H 7-30<br />

BE250H2 11-14<br />

BE260 11-14, 7-30<br />

BE260H 7-30<br />

BE260H2 11-14<br />

BE4 3-102<br />

BE412 3-102<br />

BEC3100 15-83<br />

BEC4100 15-83<br />

BF115A 11-14, 7-30<br />

BF115AH 11-14, 7-30<br />

BF115AHH 11-14, 7-30<br />

BF120A 11-14, 7-30<br />

BF120AH 11-14, 7-30<br />

BF120AHH 11-14, 7-30<br />

BF125A 7-30<br />

BF125AH 7-30<br />

BF125AHH 7-30<br />

BF130A 11-14, 7-30<br />

BF130AH 11-14, 7-30<br />

BF130AHH 11-14, 7-30<br />

BF215A 11-14, 7-30<br />

BF215AH 11-14, 7-30<br />

BF220A 11-14, 7-30<br />

BF220AH 11-14, 7-30<br />

BF230A 11-14, 7-30<br />

BF230AH 11-14, 7-30<br />

BF240A 11-14, 7-30<br />

BF240AH 11-14, 7-30<br />

BF250A 11-14, 7-30<br />

BF250AH 11-14, 7-30<br />

BF260A 11-14, 7-30<br />

BF260AH 11-14, 7-30<br />

BFC3250 15-83<br />

BFC4250 15-83<br />

BFT11200B 3-31<br />

BFT11200BU 3-31<br />

BFT11400B 3-31<br />

BFT11400BU 3-31<br />

BFT11600B 3-31<br />

BFT11600BU 3-31<br />

BFT11800B 3-31<br />

BFT11800BU 3-31<br />

BFT12000B 3-31<br />

BFT12000BU 3-31<br />

BFT31200B 3-31<br />

BFT31200BU 3-31<br />

BFT31400B 3-31<br />

BFT31400BU 3-31<br />

BFT31600B 3-31<br />

BFT31600BU 3-31<br />

BFT31800B 3-31<br />

BFT31800BU 3-31<br />

BFT32000B 3-31<br />

BFT32000BU 3-31<br />

BFTM11400B 3-31<br />

BFTM11400BU 3-31<br />

BFTM11600B 3-31<br />

BFTM11600BU 3-31<br />

BFTM11800B 3-31<br />

BFTM11800BU 3-31<br />

BFTM12000B 3-31<br />

BFTM12000BU 3-31<br />

BFTM31400B 3-31<br />

BFTM31400BU 3-31<br />

BFTM31600B 3-31<br />

BFTM31600BU 3-31<br />

BFTM31800B 3-31<br />

BFTM31800BU 3-31<br />

BFTM32000B 3-31<br />

BFTM32000BU 3-31<br />

BG215 11-14, 7-31<br />

BG220 11-14, 7-31<br />

BG330 11-14, 7-31<br />

BK1 11-11, 11-23, 11-49<br />

BK1A 11-11, 11-23<br />

BK2 11-11, 11-23<br />

BK3 11-11, 11-23<br />

BNK2 11-38<br />

BOS14321 15-83<br />

BOS14322 15-83<br />

BOS14323 15-83<br />

BOS14324 15-83<br />

BOS14351 15-83<br />

BOS14352 15-83<br />

BOS14353 15-83<br />

BOS14354 15-83<br />

BOS16421 15-83<br />

BOS16422 15-83<br />

BOS16423 15-83<br />

BOS16424 15-83<br />

BOS16451 15-83<br />

BOS16452 15-83<br />

BOS16453 15-83<br />

BOS16454 15-83<br />

BPJA1GE 15-76<br />

BPJA5GE 15-76<br />

BPJB1GE 15-76<br />

BPJB5GE 15-76<br />

BPJG1GAED200NN 15-78<br />

BPJG1GAED430NN 15-78<br />

BPJG1GAED660NN 15-78<br />

BPJG1GE 15-78<br />

BPJG5GAED200NN 15-78<br />

BPJG5GAED430NN 15-78<br />

BPJG5GAED660NN 15-78<br />

BPJG5GE 15-78<br />

BPJH1GAED200NN 15-78<br />

BPJH1GAED430NN 15-78<br />

BPJH1GAED660NN 15-78<br />

BPJH1GE 15-78<br />

BPJH5GAED200NN 15-78<br />

BPJH5GAED430NN 15-78<br />

BPJH5GAED660NN 15-78<br />

BPJH5GE 15-78<br />

BPJK1GX02030NN 15-79<br />

BPJK1GX02060NN 15-79<br />

BPJK1GX02100NN 15-79<br />

BPJK1GX06030NN 15-79<br />

BPJK1GX06060NN 15-79<br />

BPJK1GX06100NN 15-79<br />

BPJK5GX02030NN 15-79<br />

BPJK5GX02060NN 15-79<br />

BPJK5GX02100NN 15-79<br />

BPJK5GX06030NN 15-79<br />

BPJK5GX06060NN 15-79<br />

BPJK5GX06100NN 15-79<br />

BQ1B010QLD 7-39<br />

BQ1B010QXD 7-39<br />

BQ1B015 7-38<br />

BQ1B015H 7-38<br />

BQ1B015QLD 7-39<br />

BQ1B015QXD 7-39<br />

BQ1B020 7-38<br />

BQ1B020H 7-38<br />

BQ1B020QLD 7-39<br />

BQ1B020QXD 7-39<br />

BQ1B025 7-38<br />

BQ1B025H 7-38<br />

BQ1B025QLD 7-39<br />

BQ1B025QXD 7-39<br />

BQ1B030 7-38<br />

BQ1B030H 7-38<br />

BQ1B030QLD 7-39<br />

BQ1B030QXD 7-39<br />

BQ1B035 7-38<br />

BQ1B035H 7-38<br />

BQ1B035QLD 7-39<br />

BQ1B035QXD 7-39<br />

BQ1B040 7-38<br />

BQ1B040H 7-38<br />

BQ1B040QLD 7-39<br />

BQ1B040QXD 7-39<br />

BQ1B045 7-38<br />

BQ1B045QLD 7-39<br />

BQ1B045QXD 7-39<br />

BQ1B050 7-38<br />

BQ1B050H 7-38<br />

BQ1B050QLD 7-39<br />

BQ1B050QXD 7-39<br />

BQ1B060 7-38<br />

BQ1B060H 7-38<br />

BQ1B060QLD 7-39<br />

BQ1B060QXD 7-39<br />

BQ1B070H 7-38<br />

BQ2B010QLD 7-39<br />

BQ2B010QXD 7-39<br />

BQ2B015 7-38<br />

BQ2B015H 7-38<br />

BQ2B015QLD 7-39<br />

BQ2B015QXD 7-39<br />

BQ2B020 7-38<br />

BQ2B020H 7-38<br />

BQ2B020QLD 7-39<br />

BQ2B020QXD 7-39<br />

BQ2B025 7-38<br />

BQ2B025H 7-38<br />

BQ2B025QLD 7-39<br />

BQ2B025QXD 7-39<br />

BQ2B030 7-38<br />

BQ2B030H 7-38<br />

BQ2B030QLD 7-39<br />

BQ2B030QXD 7-39<br />

BQ2B035 7-38<br />

BQ2B035H 7-38<br />

BQ2B035QLD 7-39<br />

BQ2B035QXD 7-39<br />

BQ2B040 7-38<br />

BQ2B040H 7-38<br />

BQ2B040QLD 7-39<br />

BQ2B040QXD 7-39<br />

BQ2B045 7-38<br />

BQ2B045QLD 7-39<br />

BQ2B045QXD 7-39<br />

BQ2B050 7-38<br />

BQ2B050H 7-38<br />

BQ2B050QLD 7-39<br />

BQ2B050QXD 7-39<br />

BQ2B060 7-38<br />

BQ2B060H 7-38<br />

BQ2B060QLD 7-39<br />

BQ2B060QXD 7-39<br />

BQ2B070 7-38<br />

BQ2B070H 7-38<br />

BQ2B080 7-38<br />

BQ2B080H 7-38<br />

BQ2B090 7-38<br />

BQ2B090H 7-38<br />

BQ2B100 7-38<br />

BQ2B100H 7-38<br />

BQ2B110 7-38<br />

BQ2B125 7-38<br />

BQ2B125H 7-38<br />

BQ2H015 7-38<br />

BQ2H020 7-38<br />

BQ2H030 7-38<br />

BQ2H040 7-38<br />

BQ2H050 7-38<br />

BQ2H060 7-38<br />

BQ2H070 7-38<br />

BQ2H080 7-38<br />

BQ2H090 7-38<br />

BQ2H100 7-38<br />

BQ2S060 7-146<br />

BQ2S100 7-146<br />

BQ3B015 7-142, 7-38<br />

BQ3B015H 7-38<br />

BQ3B020 7-142, 7-38<br />

BQ3B020H 7-38<br />

BQ3B025 7-38<br />

BQ3B025H 7-38<br />

BQ3B030 7-142, 7-38<br />

BQ3B030H 7-38<br />

BQ3B035 7-38<br />

BQ3B035H 7-38<br />

BQ3B040 7-142, 7-38<br />

BQ3B040H 7-38<br />

BQ3B045 7-38<br />

BQ3B045H 7-38<br />

BQ3B050 7-142, 7-38<br />

BQ3B050H 7-38<br />

BQ3B060 7-142, 7-38<br />

BQ3B060H 7-38<br />

BQ3B070 7-142, 7-38<br />

BQ3B070H 7-38<br />

BQ3B080 7-38<br />

BQ3B080H 7-38<br />

BQ3B090 7-142, 7-38<br />

BQ3B090H 7-38<br />

BQ3B100 7-142, 7-38<br />

BQ3B100H 7-38<br />

BQ3S060 7-146<br />

BQ3S100 7-146<br />

BQD1100 11-13, 7-32<br />

BQD115 11-13, 7-32<br />

BQD120 11-13, 7-32<br />

BQD125 11-13, 7-32<br />

BQD130 11-13, 7-32<br />

BQD135 11-13, 7-32<br />

BQD140 11-13, 7-32<br />

BQD145 11-13, 7-32<br />

BQD150 11-13, 7-32<br />

BQD155 11-13<br />

BQD160 11-13, 7-32<br />

BQD170 11-13, 7-32<br />

BQD180 11-13, 7-32<br />

BQD190 11-13, 7-32<br />

BQD2100 11-13, 7-32<br />

BQD215 11-13, 7-32<br />

BQD220 11-13, 7-32<br />

BQD225 11-13, 7-32<br />

BQD230 11-13, 7-32<br />

BQD235 11-13, 7-32<br />

BQD240 11-13, 7-32<br />

BQD245 11-13, 7-32<br />

BQD250 11-13, 7-32<br />

BQD255 11-13<br />

BQD260 11-13, 7-32<br />

BQD270 11-13, 7-32<br />

BQD280 11-13, 7-32<br />

BQD290 11-13, 7-32<br />

BQD3100 11-13, 7-32<br />

BQD315 11-13, 7-32<br />

BQD320 11-13, 7-32<br />

BQD325 11-13, 7-32<br />

BQD330 11-13, 7-32<br />

BQD335 11-13, 7-32<br />

BQD340 11-13, 7-32<br />

BQD345 11-13, 7-32<br />

BQD350 11-13, 7-32<br />

BQD355 11-13<br />

BQD360 11-13, 7-32<br />

BQD370 11-13, 7-32<br />

BQD380 11-13, 7-32<br />

BQD390 11-13, 7-32<br />

BQD6115 7-32<br />

BQD6120 7-32<br />

BQD6125 7-32<br />

BQD6130 7-32<br />

BQD6135 7-32<br />

BQD6140 7-32<br />

BQD6145 7-32<br />

BQD6150 7-32<br />

I-10<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

BQD6160 7-32<br />

BQD6170 7-32<br />

BQD6215 7-32<br />

BQD6220 7-32<br />

BQD6225 7-32<br />

BQD6230 7-32<br />

BQD6235 7-32<br />

BQD6240 7-32<br />

BQD6245 7-32<br />

BQD6250 7-32<br />

BQD6260 7-32<br />

BQD6270 7-32<br />

BQD6315 7-32<br />

BQD6320 7-32<br />

BQD6325 7-32<br />

BQD6330 7-32<br />

BQD6335 7-32<br />

BQD6340 7-32<br />

BQD6345 7-32<br />

BQD6350 7-32<br />

BQD6360 7-32<br />

BQD6370 7-32<br />

BQDHBD 7-160<br />

BQDHT2 7-160<br />

BQDHT3 7-160<br />

BQDPLD 7-160<br />

BQFS1K 1-48, 7-158, 7-39<br />

BQFS2 1-48, 7-158, 7-39<br />

BR2 1-48, 7-158<br />

BR3 1-48, 7-158<br />

BR4 1-48, 7-158<br />

BSPD2A100 10-4<br />

BSPD3B100 10-4<br />

BSPD3C100 10-4<br />

BSPD3D100 10-4<br />

BSPD3E100 10-4<br />

BSPD3F100 10-4<br />

BSPD3G100 10-4<br />

BSPD3K100 10-4<br />

BSPD3L100 10-4<br />

BSPD3S100 10-4<br />

BSPD3T100 10-4<br />

BSPM2240S3G 11-106<br />

BSPM3480DLG 11-106<br />

BSPM4208WYNG 11-106<br />

BSPM4480WYNG 11-106<br />

BWJCRE211G 15-70<br />

BWJCRE215G 15-70<br />

BWJCRE221G 15-70<br />

BWJCRE225G 15-70<br />

BWJCRE241G 15-70<br />

BWJCRE245G 15-70<br />

BWJCTLN21GSANN 15-71<br />

BWJCTLN25GSANN 15-71<br />

BWJCTLN41GSANN 15-71<br />

BWJCTLN45GSANN 15-71<br />

BWJCTRN21GSANN 15-71<br />

BWJCTRN25GSANN 15-71<br />

BWJCTRN41GSANN 15-71<br />

BWJCTRN45GSANN 15-71<br />

BWJELEL11G 15-69<br />

BWJELEL15G 15-69<br />

BWJELEL21G 15-69<br />

BWJELEL25G 15-69<br />

BWJELEL41G 15-69<br />

BWJELEL45G 15-69<br />

BWJELER11G 15-69<br />

BWJELER15G 15-69<br />

BWJELER21G 15-69<br />

BWJELER25G 15-69<br />

BWJELER41G 15-69<br />

BWJELER45G 15-69<br />

BWJELFL11G 15-69<br />

BWJELFL15G 15-69<br />

BWJELFL21G 15-69<br />

BWJELFL25G 15-69<br />

BWJELFL41G 15-69<br />

BWJELFL45G 15-69<br />

BWJELFR11G 15-69<br />

BWJELFR15G 15-69<br />

BWJELFR21G 15-69<br />

BWJELFR25G 15-69<br />

BWJELFR41G 15-69<br />

BWJELFR45G 15-69<br />

BWJETBR11GS 15-72<br />

BWJETBR15GS 15-72<br />

BWJETBR21GS 15-72<br />

BWJETBR25GS 15-72<br />

BWJETBR41GS 15-72<br />

BWJETBR45GS 15-72<br />

BWJF12011GS1 15-68<br />

BWJF12021GS1 15-68<br />

BWJF12041GS1 15-68<br />

BWJFENN11GS 15-73<br />

BWJFENN15GS 15-73<br />

BWJFENN21GS 15-73<br />

BWJFENN25GS 15-73<br />

BWJFENN41GS 15-73<br />

BWJFENN45GS 15-73<br />

BWJH0011G 15-74<br />

BWJH0012G 15-74<br />

BWJH0014G 15-74<br />

BWJJ1GXPB100NN 15-79<br />

BWJJ1GXPB200NN 15-79<br />

BWJJ5GXPB100NN 15-79<br />

BWJJ5GXPB200NN 15-79<br />

BWJP02411GS1 15-68<br />

BWJP02415GS1 15-68<br />

BWJP02421GS1 15-68<br />

BWJP02425GS1 15-68<br />

BWJP02441GS1 15-68<br />

BWJP02445GS1 15-68<br />

BWJP06011GS1 15-68<br />

BWJP06015GS1 15-68<br />

BWJP06021GS1 15-68<br />

BWJP06025GS1 15-68<br />

BWJP06041GS1 15-68<br />

BWJP06045GS1 15-68<br />

BWJP12011GS1 15-68<br />

BWJP12015GS1 15-68<br />

BWJP12021GS1 15-68<br />

BWJP12025GS1 15-68<br />

BWJP12041GS1 15-68<br />

BWJP12045GS1 15-68<br />

BWJTEE211G 15-70<br />

BWJTEE215G 15-70<br />

BWJTEE221G 15-70<br />

BWJTEE225G 15-70<br />

BWJTEE241G 15-70<br />

BWJTEE245G 15-70<br />

BWJTEE411G 15-70<br />

BWJTEE415G 15-70<br />

BWJTEE421G 15-70<br />

BWJTEE425G 15-70<br />

BWJTEE441G 15-70<br />

BWJTEE445G 15-70<br />

BWJXENN1G 15-74<br />

BWJXENN2G 15-74<br />

BWJXENN4G 15-74<br />

BWJXOCN1G 15-74<br />

BWJXOCN2G 15-74<br />

BWJXOCN4G 15-74<br />

BZLF3 7-216<br />

BZLFBDC 7-216<br />

BZLFRHSE 7-216<br />

BZLL3 7-217<br />

BZLLBDC 7-217<br />

BZLLRHSE 7-217<br />

BZLM3 7-217<br />

BZLMRHSE 7-217<br />

BZLP3 7-217<br />

BZLPRHSE 7-217<br />

C01FD64 7-116<br />

C1A18BL100CTS 11-99<br />

C1A18E4125CTS 11-99<br />

C1A18FX250CTS 11-99<br />

C1A18ML125CTS 11-99<br />

C1A18ML250CTS 11-99<br />

C1A18QR225CTS 11-99<br />

C1A30BL100CTS 11-99<br />

C1A30E4125CTS 11-99<br />

C1A30FX250CTS 11-99<br />

C1A30ML125CTS 11-99<br />

C1A30ML250CTS 11-99<br />

C1A30QR225CTS 11-99<br />

C1A42BL100CTS 11-99<br />

C1A42E4125CTS 11-99<br />

C1A42FX250CTS 11-99<br />

C1A42ML125CTS 11-99<br />

C1A42ML250CTS 11-99<br />

C1A42QR225CTS 11-99<br />

C1C18BL100CTS 11-99<br />

C1C18E4125CTS 11-99<br />

C1C18FX250CTS 11-99<br />

C1C18ML125CTS 11-99<br />

C1C18ML250CTS 11-99<br />

C1C18QR225CTS 11-99<br />

C1C30BL100CTS 11-99<br />

C1C30E4125CTS 11-99<br />

C1C30FX250CTS 11-99<br />

C1C30ML125CTS 11-99<br />

C1C30ML250CTS 11-99<br />

C1C30QR225CTS 11-99<br />

C1C42BL100CTS 11-99<br />

C1C42E4125CTS 11-99<br />

C1C42FX250CTS 11-99<br />

C1C42ML125CTS 11-99<br />

C1C42ML250CTS 11-99<br />

C1C42QR225CTS 11-99<br />

C2E18BD100CTS 11-99<br />

C2E18E4125CTS 11-99<br />

C2E18FX225CTS 11-99<br />

C2E18FX250CTS 11-99<br />

C2E18ML125CTS 11-99<br />

C2E18ML250CTS 11-99<br />

C2E30BD100CTS 11-99<br />

C2E30E4125CTS 11-99<br />

C2E30FX225CTS 11-99<br />

C2E30FX250CTS 11-99<br />

C2E30ML125CTS 11-99<br />

C2E30ML250CTS 11-99<br />

C2E42BD100CTS 11-99<br />

C2E42E4125CTS 11-99<br />

C2E42FX225CTS 11-99<br />

C2E42FX250CTS 11-99<br />

C2E42ML125CTS 11-99<br />

C2E42ML250CTS 11-99<br />

CBCF18 7-214<br />

CBCM36 7-214, 7-215<br />

CBCP54 7-214, 7-215<br />

CBTF 7-214<br />

CBTL 7-215<br />

CBTM 7-215<br />

CBTP 7-215<br />

CCE125 7-111, 7-155<br />

CCF250 7-114, 7-155<br />

CCL600 7-117, 7-119, 7-121, 7-155<br />

CCM800K2 7-155<br />

CCM800K3 7-155<br />

CCN1200K2 7-155<br />

CCN1200K3 7-155<br />

CCQ250 7-155, 7-40<br />

CED62B015 7-112<br />

CED62B020 7-112<br />

CED62B030 7-112<br />

CED62B060 7-112<br />

CED62B070 7-112<br />

CED62B080 7-112<br />

CED62B090 7-112<br />

CED62B100 7-112<br />

CED62B125 7-112<br />

CED62S100A 7-146<br />

CED62S125A 7-146<br />

CED63A001 7-140, 7-141, 7-143<br />

CED63A002 7-140, 7-141, 7-143<br />

CED63A003 7-140, 7-141, 7-143<br />

CED63A005 7-140, 7-141, 7-143<br />

CED63A010 7-140, 7-141, 7-143<br />

CED63A025 7-140, 7-141, 7-143<br />

CED63A030 7-140, 7-141, 7-143<br />

CED63A040 7-140, 7-141, 7-143<br />

CED63A050 7-140, 7-141, 7-143<br />

CED63A100 7-140, 7-141, 7-143<br />

CED63A125 7-140, 7-141, 7-143<br />

CED63B015 7-112<br />

CED63B020 7-112<br />

CED63B030 7-112<br />

CED63B040 7-112<br />

CED63B050 7-112<br />

CED63B060 7-112<br />

CED63B070 7-112<br />

CED63B080 7-112<br />

CED63B090 7-112<br />

CED63B100 7-112<br />

CED63B110 7-112<br />

CED63B125 7-112<br />

CED63S100A 7-146<br />

CED63S125A 7-146<br />

CED6N12 6-13, 7-111<br />

CED6N1F 6-8, 7-111<br />

CED6N1S 6-8, 7-111<br />

CED6N3R 6-10, 7-111<br />

CFD62B070 7-143<br />

CFD62B080 7-143<br />

CFD62B090 7-143<br />

CFD62B100 7-143<br />

CFD62B110 7-143<br />

CFD62B125 7-143<br />

CFD62B150 7-143<br />

CFD62B175 7-143<br />

CFD62B200 7-143<br />

CFD62B225 7-143<br />

CFD62B250 7-143<br />

CFD63A150 7-140, 7-141, 7-143<br />

CFD63A250 7-140, 7-141, 7-143<br />

CFD63B070 7-115, 7-143<br />

CFD63B080 7-115, 7-143<br />

CFD63B090 7-115, 7-143<br />

CFD63B100 7-115, 7-143<br />

CFD63B110 7-115, 7-143<br />

CFD63B12 7-115<br />

CFD63B125 7-143<br />

CFD63B150 7-115, 7-143<br />

CFD63B175 7-115, 7-143<br />

CFD63B200 7-115, 7-143<br />

CFD63B225 7-115, 7-143<br />

CFD63B250 7-115, 7-143<br />

CFD63H150 7-140, 7-143<br />

CFD63L150 7-140, 7-141, 7-143<br />

CFD63S250A 7-146<br />

CFS11AUX 5-17<br />

CFS22AUX 5-17<br />

CFS361C5 5-16, 5-18<br />

CFS361J5 5-16, 5-18<br />

CFS361JLN 5-16, 5-18<br />

CFS361JN 5-16, 5-18<br />

CFS362JLN 5-16, 5-18<br />

CFS362JN 5-16, 5-18<br />

CFS362JN1 5-16, 5-18<br />

CFS363JLN 5-16, 5-18<br />

CFS363JN 5-16, 5-18<br />

CFS364JN 5-16, 5-18<br />

CFS365JN 5-16, 5-18<br />

CFS366J 5-16, 5-18<br />

CFS367L 5-16, 5-18<br />

CFS466J 5-18<br />

CFS467L 5-18<br />

CFSAUX1NC 5-17<br />

CFSAUX1NO 5-17<br />

CFSAUXH1 5-17<br />

CFSH10B12N 5-16<br />

CFSH10B4N 5-16<br />

CFSH10BL12N 5-16, 5-21<br />

CFSH10BL4N 5-16, 5-21<br />

CFSH10R12N 5-16<br />

CFSH10R4N 5-16<br />

CFSH10RL12N 5-16, 5-21<br />

CFSH10RL4N 5-16, 5-21<br />

CFSH12BL12 5-17, 5-21<br />

CFSH12BL4 5-17, 5-21<br />

CFSH12RL12 5-17, 5-21<br />

CFSH12RL4 5-17, 5-21<br />

CFSH5B12N 5-16<br />

CFSH5B4N 5-16<br />

CFSH5CDM 5-17<br />

CFSH5JDM 5-17<br />

CFSH5R12N 5-16<br />

CFSH5R4N 5-16<br />

CFSL200 5-17, 5-22<br />

CFSL400 5-17, 5-22<br />

CFSL400N 5-17, 5-22<br />

CFSNFPA1 5-17<br />

CFSNFPA2N 5-17<br />

CFSNFPA3N 5-17<br />

CFSPLK 5-17<br />

CFSS10200HN 5-16, 5-21<br />

CFSS10400HN 5-16, 5-21<br />

CFSS12200H 5-17<br />

CFSS12400H 5-17<br />

CFSS5200HN 5-16<br />

CFSS5200N 5-16<br />

CFSS5400HN 5-16<br />

CFSS5400N 5-16<br />

CFSSB100 5-17<br />

CFSSB200 5-17<br />

CFSSB400 5-17<br />

CFSSB60 5-17<br />

CFSSB680 5-17<br />

CFSTS200N 5-17<br />

CFSTS400N 5-17<br />

CFSTS680 5-17<br />

CFSTS6804 5-17<br />

CJD63B400 7-144<br />

CJD63B200 7-118, 7-144<br />

CJD63B225 7-118, 7-144<br />

CJD63B250 7-118, 7-144<br />

CJD63B300 7-118, 7-144<br />

CJD63B350 7-118, 7-144<br />

CJD63B400 7-118<br />

CJD63H400 7-140, 7-141, 7-144<br />

CJD63L400 7-140, 7-141, 7-144<br />

CJD63S400A 7-146<br />

CJT2B250 7-184<br />

CJT2B300 7-184<br />

CJT2B350 7-184<br />

CJT2B400 7-184<br />

CJT3A250 7-185<br />

CJT3A400 7-185<br />

CJT3B250 7-184<br />

CJT3B300 7-184<br />

CJT3B350 7-184<br />

CJT3B400 7-184<br />

CJT3G250 7-185<br />

CJT3G400 7-185<br />

CJT3K250 7-185<br />

CJT3K400 7-185<br />

CJT3R250 7-185<br />

CJT3R400 7-185<br />

CJT3T250 7-185<br />

CJT3T400 7-185<br />

CJT3V250 7-185<br />

CJT3V400 7-185<br />

CJT3W250 7-185<br />

CJT3W400 7-185<br />

CLD63B400 7-144<br />

CLD63B450 7-122, 7-144<br />

CLD63B500 7-122, 7-144<br />

CLD63B600 7-122, 7-144<br />

CLD63H600 7-140, 7-141, 7-144<br />

CLD63L600 7-140, 7-141, 7-144<br />

CLD63S600A 7-146<br />

CLKF 7-210<br />

CLKP 7-211<br />

CLM Series Lighting Control<br />

17-93, 17-94<br />

CLRSJL3 7-165<br />

CM Series Lighting Control 17-98<br />

CMD63A800 7-140, 7-141, 7-145<br />

CMD63B600 7-129, 7-145<br />

CMD63B700 7-129, 7-145<br />

CMD63B800 7-129, 7-145<br />

CMD63H800 7-140, 7-141, 7-145<br />

CMD63L800 7-140, 7-141, 7-145<br />

CMD63S800A 7-146<br />

CMT2B600 7-192<br />

CMT2B700 7-192<br />

CMT2B800 7-192<br />

CMT3A600 7-193<br />

CMT3A800 7-193<br />

CMT3B600 7-192<br />

CMT3B700 7-192<br />

CMT3B800 7-192<br />

CMT3G600 7-193<br />

CMT3G800 7-193<br />

CMT3K600 7-193<br />

CMT3K800 7-193<br />

CMT3R600 7-193<br />

CMT3R800 7-193<br />

CMT3T600 7-193<br />

CMT3T800 7-193<br />

CMT3V600 7-193<br />

CMT3V800 7-193<br />

CMT3W600 7-193<br />

CMT3W800 7-193<br />

CND63B100 7-133, 7-145<br />

CND63B120 7-133, 7-145<br />

CND63B800 7-145<br />

CND63B900 7-133, 7-145<br />

CND63S120A 7-146<br />

CNFS1AUX1 5-22<br />

CNFS1AUX2 5-22<br />

CNFS2AUX1 5-22<br />

CNFS2AUX2 5-22<br />

CNFS361N 5-21<br />

CNFS362N 5-21<br />

CNFS363N 5-21<br />

CNFS364N 5-21<br />

CNFS365N 5-21<br />

CNFS366N 5-21<br />

CNFS367N 5-21<br />

CNFSH5BP121 5-21<br />

CNFSH5BP41 5-21<br />

CNFSH5RP121 5-21<br />

CNFSH5RP41 5-21<br />

CNFSHD1 5-21<br />

CNFSHD2 5-21<br />

CNFSHD3 5-21<br />

CNFSL400D 5-17, 5-22<br />

CNFSS103202 5-21<br />

CNFSS152003 5-21<br />

I<br />

PRODUCT<br />

INDEX<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog I-11


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

I<br />

PRODUCT<br />

INDEX<br />

CNFSS153203 5-21<br />

CNFSS154003 5-21<br />

CNFSS52001 5-21<br />

CNFSS53201 5-21<br />

CNFSS54001 5-21<br />

CNFSTS100 5-22<br />

CNFSTSC200B 5-22<br />

CNFSTSC200T 5-22<br />

CNFSTSC400B 5-22<br />

CNFSTSC400T 5-22<br />

CNFSTSC600B 5-22<br />

CNFSTSC800B 5-22<br />

CNKL18 11-11<br />

CNKL30 11-11<br />

CNKL42 11-11<br />

CNLK18 11-22<br />

CNLK30 11-22<br />

CNLK30A 11-11, 11-22<br />

CNLK42 11-22<br />

CNLK42A 11-11, 11-22<br />

CNLK54A 11-11, 11-22<br />

CNT2B100 7-196<br />

CNT2B120 7-196<br />

CNT2B800 7-196<br />

CNT2B900 7-196<br />

CNT3A100 7-197<br />

CNT3A120 7-197<br />

CNT3A800 7-197<br />

CNT3B100 7-196<br />

CNT3B120 7-196<br />

CNT3B800 7-196<br />

CNT3B900 7-196<br />

CNT3G100 7-197<br />

CNT3G120 7-197<br />

CNT3G800 7-197<br />

CNT3K100 7-197<br />

CNT3K120 7-197<br />

CNT3K800 7-197<br />

CNT3R100 7-197<br />

CNT3R120 7-197<br />

CNT3R800 7-197<br />

CNT3T100 7-197<br />

CNT3T120 7-197<br />

CNT3T800 7-197<br />

CNT3V100 7-197<br />

CNT3V120 7-197<br />

CNT3V800 7-197<br />

CNT3W100 7-197<br />

CNT3W120 7-197<br />

CNT3W800 7-197<br />

COMKIT3 7-216<br />

COMKIT4 7-217<br />

COMKIT5 7-217<br />

COMKIT6 7-216<br />

COMKIT7 7-217<br />

COMKIT8 7-217<br />

COMMOD21 7-216, 7-217<br />

COMPCA 7-120, 7-124, 7-127, 7-131,<br />

7-135, 7-138, 7-216, 7-217<br />

COMPRO20 7-216, 7-217<br />

CPD63B120 7-136, 7-145<br />

CPD63B140 7-136, 7-145<br />

CPD63B160 7-136, 7-145<br />

CPT3A120 7-200<br />

CPT3A160 7-200<br />

CPT3G120 7-200<br />

CPT3G160 7-200<br />

CPT3K120 7-200<br />

CPT3K160 7-200<br />

CPT3R120 7-200<br />

CPT3R160 7-200<br />

CPT3T120 7-200<br />

CPT3T160 7-200<br />

CPT3V120 7-200<br />

CPT3V160 7-200<br />

CPT3W120 7-200<br />

CPT3W160 7-200<br />

CQD1100 7-42<br />

CQD115 7-42<br />

CQD120 7-42<br />

CQD125 7-42<br />

CQD130 7-42<br />

CQD135 7-42<br />

CQD140 7-42<br />

CQD145 7-42<br />

CQD150 7-42<br />

CQD160 7-42<br />

CQD170 7-42<br />

CQD180 7-42<br />

CQD190 7-42<br />

CQD2100 7-42<br />

CQD215 7-42<br />

CQD220 7-42<br />

CQD225 7-42<br />

CQD230 7-42<br />

CQD235 7-42<br />

CQD240 7-42<br />

CQD245 7-42<br />

CQD250 7-42<br />

CQD260 7-42<br />

CQD270 7-42<br />

CQD280 7-42<br />

CQD290 7-42<br />

CQD3100 7-42<br />

CQD315 7-42<br />

CQD320 7-42<br />

CQD325 7-42<br />

CQD330 7-42<br />

CQD335 7-42<br />

CQD340 7-42<br />

CQD345 7-42<br />

CQD350 7-42<br />

CQD360 7-42<br />

CQD370 7-42<br />

CQD380 7-42<br />

CQD390 7-42<br />

CQDA1 7-35, 7-44<br />

CQDA1BA 7-35, 7-44<br />

CQDA2 7-35, 7-44<br />

CQDBA 7-35, 7-44<br />

CQDFMB1 7-161<br />

CQDFMB2 7-161<br />

CQDFMB3 7-161<br />

CQDOP 7-162<br />

CQDSMK 7-161<br />

CQDST12 7-35, 7-44<br />

CQDST120 7-35, 7-44<br />

CQDST120AAS 7-35, 7-44<br />

CQDST125 7-35, 7-44<br />

CQDST125DAS 7-35, 7-44<br />

CQDST12DAS 7-35, 7-44<br />

CQDST24 7-35, 7-44<br />

CQDST240 7-35, 7-44<br />

CQDST240AAS 7-35, 7-44<br />

CQDST24AAS 7-35, 7-44<br />

CQDST24DAS 7-35, 7-44<br />

CQDST277 7-35, 7-44<br />

CQDST277AAS 7-35, 7-44<br />

CQDST48 7-35, 7-44<br />

CQDST480 7-35, 7-44<br />

CQDST480AAS 7-35, 7-44<br />

CQDST48DAS 7-35, 7-44<br />

CQDST600 7-35, 7-44<br />

CQDST600AAS 7-35, 7-44<br />

CRHOESD 7-162<br />

CRHOEVD 7-162<br />

CRHOFSD 7-162<br />

CRHOFVD 7-162<br />

CRHOH 5-13, 7-162<br />

CRHOJSD 7-162<br />

CRHOJVD 7-162<br />

CRHOLMSD 7-162<br />

CRHOLMVD 7-162<br />

CRHOS06VD 5-13<br />

CRHOS20VD 5-13<br />

CTB302 15-80<br />

CTB304 15-80<br />

CTB306 15-80<br />

CTB308 15-80<br />

CTB310 15-80<br />

CTB313 15-80<br />

CTB316 15-80<br />

CTB4024 15-80<br />

CTB4044 15-80<br />

CTB4064 15-80<br />

CTB4084 15-80<br />

CTB4101 15-80<br />

D115 1-44, 7-23<br />

D11CEU1 7-162<br />

D11CEU2 7-162<br />

D11CFU1 7-162<br />

D11CFU2 7-162<br />

D11CJU2 7-162<br />

D120 1-44, 7-23<br />

D130 1-44, 7-23<br />

D140 1-44, 7-23<br />

D150 1-44, 7-23<br />

D160 1-44, 7-23<br />

D215 1-44, 7-23<br />

D220 1-44, 7-23<br />

D230 1-44, 7-23<br />

D240 1-44, 7-23<br />

D250 1-44, 7-23<br />

D260 1-44, 7-23<br />

DFFP01A 11-15<br />

DFFP1 11-11, 11-23, 11-38,<br />

11-49, 11-77, 11-91, 13-26<br />

DFFP1 11-15<br />

DFFP3 11-15, 11-38, 11-49<br />

DFFP6 11-15, 11-38, 11-49<br />

DFFPED01 11-15<br />

DFFPFD01 11-15<br />

DFFPJD01 11-15<br />

DFFPQJ01 11-15<br />

DFFPQJ02 11-15<br />

DFK1 11-15, 11-38<br />

DFP3AP01 11-15<br />

DKL2 7-162<br />

DKL3 7-162<br />

DKR2 5-9, 7-162<br />

DKR3 5-9, 7-162<br />

DS100GK 4-32<br />

DS200EK1 4-32<br />

DS200EK2 4-32<br />

DS200GK 4-32<br />

DS468GK 4-32<br />

DS800NK 4-32<br />

DT100NK 4-32<br />

DT200NK 4-32<br />

DT600NK 4-32<br />

DTF224 4-31, 4-33<br />

DTF224R 4-31, 4-33<br />

DTF321 4-31, 4-33<br />

DTF321R 4-31, 4-33<br />

DTF322 4-31, 4-33<br />

DTF322R 4-31, 4-33<br />

DTF323 4-31, 4-33<br />

DTF323R 4-31, 4-33<br />

DTF324 4-31, 4-33<br />

DTF324R 4-31, 4-33<br />

DTF325 4-31, 4-33<br />

DTF326 4-31, 4-33<br />

DTF361 4-31, 4-33<br />

DTF362 4-31, 4-33<br />

DTF363 4-31, 4-33<br />

DTF363R 4-31, 4-33<br />

DTF364 4-31, 4-33<br />

DTF364R 4-31, 4-33<br />

DTF365 4-31, 4-33<br />

DTGNF223NR 4-31, 4-33<br />

DTGNF223R 4-31, 4-33<br />

DTGNF224NR 4-31, 4-33<br />

DTGNF224R 4-31<br />

DTGNF323NR 4-31, 4-33<br />

DTGNF323R 4-31, 4-33<br />

DTGNF324NR 4-31<br />

DTGNF324R 4-31<br />

DTLNF213NR 4-31<br />

DTNF221 4-31, 4-33<br />

DTNF222 4-31, 4-33<br />

DTNF223 4-31, 4-33<br />

DTNF224 4-31, 4-33<br />

DTNF224R 4-31, 4-33<br />

DTNF225 4-31, 4-33<br />

DTNF225R 4-31, 4-33<br />

DTNF321 4-31, 4-33<br />

DTNF322 4-31, 4-33<br />

DTNF323 4-31, 4-33<br />

DTNF323R 4-31, 4-33<br />

DTNF324 4-31, 4-33<br />

DTNF324R 4-31, 4-33<br />

DTNF325 4-31, 4-33<br />

DTNF326 4-31, 4-33<br />

DTNF327 4-31, 4-33<br />

DTNF361 4-31, 4-33<br />

DTNF361J 4-31, 4-33<br />

DTNF361R 4-31, 4-33<br />

DTNF361S 4-31, 4-33<br />

DTNF362 4-31, 4-33<br />

DTNF362J 4-31, 4-33<br />

DTNF362R 4-31, 4-33<br />

DTNF362S 4-31, 4-33<br />

DTNF363 4-31, 4-33<br />

DTNF363J 4-31, 4-33<br />

DTNF363R 4-31, 4-33<br />

DTNF363S 4-31, 4-33<br />

DTNF364 4-31, 4-33<br />

DTNF364J 4-31, 4-33<br />

DTNF364R 4-31, 4-33<br />

DTNF364S 4-31, 4-33<br />

DTNF365 4-31, 4-33<br />

DTNF365R 4-31, 4-33<br />

DTNF366 4-31, 4-33<br />

DTNF366R 4-31, 4-33<br />

DTNF367 4-31, 4-33<br />

DTNF367R 4-31, 4-33<br />

DTNF368 4-31, 4-33<br />

DTNF368R 4-31, 4-33<br />

E0202MB1100 1-20<br />

E0202MB1200 1-20<br />

E0204ML1060F 1-20<br />

E0204ML1060S 1-20, 6-8<br />

E0204ML1125FCU 1-20<br />

E0204ML1125SCU 1-20<br />

E0303ML3100S 1-20, 6-8<br />

E0408ML1125F 1-19<br />

E0408ML1125S 1-19<br />

E0816ML1125F 1-19<br />

E0816ML1125FCU 1-19<br />

E0816ML1125FGB 1-19<br />

E0816ML1125S 1-19<br />

E0816ML1125SCU 1-19<br />

E1020MB1100FCGP 1-19<br />

E1224ML1100FCU 1-19<br />

E1224ML1100FG 1-19<br />

E2BMB 7-161<br />

E2HBL 13-19, 7-160<br />

E2N12 6-13, 7-111<br />

E2N1F 6-8, 7-111<br />

E2N1S 6-8, 7-111<br />

E2N3R 6-10, 7-111<br />

E2RH1 7-162<br />

E2RHV9 7-162<br />

E3030MB1400SCU 1-16<br />

E3030MB3400SCU 1-16<br />

E3030ML1400SCU 1-16<br />

E3030ML3400SCU 1-16<br />

E4242MB1300FCU 1-16<br />

E4242MB1300SCU 1-16<br />

E4242MB1400FCU 1-16<br />

E4242MB1400SCU 1-16<br />

E4242MB3300SCU 1-16<br />

E4242MB3400FCU 1-16<br />

E4242MB3400SCU 1-16<br />

E4242ML1400FCU 1-16<br />

E4242ML1400SCU 1-16<br />

E4242ML3400FCU 1-16<br />

E4242ML3400SCU 1-16<br />

EA 6-12, 7-111<br />

EB 6-12, 7-111<br />

EB3100S 1-20, 6-8, 7-39<br />

EBF1 11-11, 11-15, 11-23,<br />

11-38, 11-49, 11-77, 11-91<br />

EC1GB8 1-22<br />

EC1GB82 1-22<br />

EC2 6-12, 7-114<br />

EC2GB12 1-22<br />

EC2GB122 1-22<br />

EC2GB15 1-22<br />

EC2GB152 1-22<br />

EC38594 2-25, 2-51, 2-77, 3-130, 3-137<br />

EC38595 2-25, 2-50, 2-51, 2-77, 3-137<br />

EC38596 2-25, 2-50, 2-51,<br />

2-77, 3-130, 3-137<br />

EC38597 2-25, 2-50, 2-51,<br />

2-77, 3-130, 3-137<br />

EC38598 2-25, 2-50, 2-51,<br />

2-77, 3-130, 3-137<br />

EC38599 2-25, 2-50, 2-51, 2-77, 3-137<br />

EC38600 2-25, 2-50, 2-51, 2-77, 3-137<br />

EC3GB21 1-22<br />

EC3GB212 1-22<br />

EC3GB27 1-22<br />

EC3GB272 1-22<br />

EC3GB30 1-22<br />

EC3GB302 1-22<br />

EC3GB352 1-22<br />

EC3GB352G 1-22<br />

EC3PMFP1 1-22<br />

EC3PMFPR 1-22<br />

EC4 6-12, 7-118<br />

EC56854 2-51, 2-76, 3-130, 3-137<br />

EC56855 2-51, 2-76, 3-130, 3-137<br />

EC56856 2-25, 2-51, 2-76, 3-130, 3-137<br />

EC56857 2-25, 2-51, 2-76, 3-130, 3-137<br />

EC56858 2-25, 2-51, 2-76, 3-130, 3-137<br />

EC56933S 2-25, 2-51, 2-76, 3-130, 3-137<br />

EC5J 2-25, 2-51, 2-77<br />

EC5J2 2-51, 2-77<br />

EC64685 2-25<br />

EC659-0120 2-25<br />

EC659-0121 2-25, 2-51<br />

EC9747-1113 2-25, 2-51,<br />

2-77, 3-130, 3-137<br />

ECA10 15-80<br />

ECA8 15-80<br />

ECADHLCDIRLBL 1-22<br />

ECAFL 1-22, 3-133<br />

ECBC 3-131<br />

ECBONDSCRW 1-22<br />

ECBX231M 1-40, 1-48, 7-19, 7-30<br />

ECCP1 1-22<br />

ECCP3 2-25, 2-51, 2-77, 3-131, 3-137<br />

ECCP3U 3-138<br />

ECCS1 1-22<br />

ECCS2 1-22<br />

ECFRK1 2-76<br />

ECFRK2 2-76<br />

ECGB10 1-22<br />

ECGB101 1-22<br />

ECGB14 1-22<br />

ECGB141 1-22<br />

ECGB142 1-22<br />

ECGB20 1-22<br />

ECGB201 1-22<br />

ECGB202 1-22<br />

ECGB5 1-22<br />

ECGK 11-11, 11-23, 11-38, 11-49<br />

ECGLK3300 3-133<br />

ECGLK6300 3-133<br />

ECHA000 1-22, 4-22<br />

ECHA075 1-22, 4-22<br />

ECHA100 1-22, 4-22<br />

ECHA125 1-22, 4-22<br />

ECHA150 1-22<br />

ECHBK 3-138<br />

ECHC000 2-50, 2-51, 2-77<br />

ECHC200 2-50, 2-51, 2-77<br />

ECHC250 2-50, 2-51, 2-77<br />

ECHC300 2-50, 2-51, 2-77<br />

ECHCRXA 2-50, 2-51<br />

ECHR075 6-14<br />

ECHR100 6-14<br />

ECHR125 6-14<br />

ECHR150 6-14<br />

ECHR200 6-14<br />

ECHS000 1-22, 2-77, 4-22<br />

ECHS075 1-22, 4-22, 4-32, 6-14<br />

ECHS100 1-22, 4-22, 4-32, 6-14<br />

ECHS125 1-22, 4-22, 4-32, 6-14<br />

ECHS150 1-22, 4-22, 4-32, 6-14<br />

ECHS200 1-22, 4-22, 4-32, 6-14<br />

ECHS250 1-22, 4-22, 4-32, 6-14<br />

ECHV000 1-22, 2-77<br />

ECHV200 1-22, 6-14<br />

ECHV250 1-22, 4-22, 6-14<br />

ECHV300 1-22, 4-22, 6-14<br />

ECHV350 1-22, 4-22, 6-14<br />

ECHV400 1-22, 4-22, 6-14<br />

ECINSGB14 1-22<br />

ECINSGB20 1-22<br />

ECINSGB5 1-22<br />

ECJS 2-25, 3-130<br />

ECLCHINGE 1-22<br />

ECLK1<br />

ECLK2<br />

ECLK3 2-77<br />

ECLK1-2 1-22, 2-51<br />

ECLK2 1-22, 2-51<br />

ECLK2125 1-22<br />

ECLK2225 1-22<br />

ECLK2N 1-22<br />

ECLK2SC 1-22<br />

ECLK3 1-22, 2-51<br />

ECLK3225 1-22<br />

ECLK3N 1-22<br />

ECLKB1 1-22<br />

ECLTB1 1-24<br />

ECLTB2 1-24<br />

ECLTB3 1-24<br />

ECLTB4 1-24<br />

ECLX068M 2-51, 2-77<br />

ECLX069M 2-51, 2-77<br />

ECLX071M 2-51, 2-77<br />

ECLX072M 2-51, 2-77<br />

ECLX073M 2-51, 2-77<br />

ECLX074M 2-51, 2-77<br />

ECLX075M 2-51, 2-77<br />

ECLX387HD 1-24<br />

ECMBF125 1-22<br />

I-12<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

ECMBR1 1-24, 1-48, 7-158<br />

ECMBR2 1-24, 1-48, 7-158<br />

ECMBR3 1-24, 1-48<br />

ECMF5 3-132<br />

ECMFBM1 3-132<br />

ECMFBM2 3-132<br />

ECMFC 3-133<br />

ECMFCS 3-131<br />

ECMFGN125 3-131<br />

ECMFH 3-132<br />

ECMFMC 3-132<br />

ECMFMC10 3-134<br />

ECMFMCR 3-132<br />

ECMFN225 3-131<br />

ECMFPK 3-131<br />

ECMFPS 3-133<br />

ECMFS 3-132<br />

ECMFTAB 3-131<br />

ECMFWLCLIP 3-132<br />

ECML3BC1 3-134<br />

ECML3BC2 3-134<br />

ECML3BC3 3-134<br />

ECML3BC4 3-134<br />

ECMLK125 1-22<br />

ECMLK225 1-22<br />

ECMLK3125 1-22<br />

ECMLK3225 1-22, 3-106, 3-107,<br />

3-108, 3-109, 3-137<br />

ECMLNKOP 3-132<br />

ECMM5J 3-138<br />

ECMMBC 3-131<br />

ECMMBCL 3-131<br />

ECMMBCM 3-131<br />

ECMMFSP400 3-133<br />

ECMMFSP600 3-133<br />

ECMMFSP800 3-133<br />

ECMMGBE 3-133<br />

ECMMKOP 3-131<br />

ECMMNKOP 3-132<br />

ECMMQRSCR 3-133<br />

ECMMRCK 3-133<br />

ECMMRLCK 3-133<br />

ECMMRS 3-131<br />

ECMT3BC1 3-134<br />

ECMT3BC2 3-134<br />

ECMT3BC3 3-134<br />

ECMT5 3-132<br />

ECP10 15-80<br />

ECP6 15-80<br />

ECPLD1 1-40, 1-48, 7-158, 7-19, 7-30<br />

ECPLD1R 1-48, 7-158<br />

ECPLD2 1-40, 1-48, 7-158, 7-19, 7-30<br />

ECPLD2R 1-48, 7-158<br />

ECPLD3 1-48, 7-158<br />

ECPP 2-25, 2-51, 2-77, 3-130, 3-137<br />

ECQF3 1-22, 1-48, 7-158<br />

ECQFL1 1-22<br />

ECQFL2 1-22<br />

ECQFL3 1-22<br />

ECQL1 1-48, 13-19<br />

ECQLD3 1-48, 13-19, 7-158<br />

ECQLD4 1-48, 7-158<br />

ECQLN3 1-48, 7-158<br />

ECQML12 1-48, 7-158<br />

ECQTH2 1-48, 7-158<br />

ECQTH3 1-48, 7-158<br />

ECQTH4 1-48, 7-158<br />

ECRLK250 1-22<br />

ECSBPK01 1-25<br />

ECSBPK02 1-25<br />

ECSBPK03 1-25<br />

ECSBPK04 1-25<br />

ECSBPK05 1-25<br />

ECSBPK06 1-25<br />

ECSBPK07 1-25<br />

ECSBPK10 1-25<br />

ECSBPK11 1-25<br />

ECSIELATCH 1-22<br />

ECSMK1 1-22<br />

ECSN1 1-22<br />

ECTS2 1-22<br />

ECTS2W 1-22<br />

ECW3MMBC1 3-134<br />

ECW3MMBC2 3-134<br />

ECW3MMBC3 3-134<br />

ECW3MMBC4 3-134<br />

ECW3MMUBC1 3-134<br />

ECW3MMUBC2 3-134<br />

ECW3MMUBC3 3-134<br />

ECW3MMUBC4 3-134<br />

ECW3USSBC1 3-134<br />

ECW3USSBC2 3-134<br />

ECW3USSBC3 3-134<br />

ECWML10 3-134, 3-69<br />

ECWML3BC1 3-134<br />

ECWML3BC2 3-134<br />

ECWML3BC3 3-134<br />

ECWML3BC4 3-134<br />

ECWMLC 3-134<br />

ECWMLPS 3-133<br />

ECWMLZBP 3-134, 3-69<br />

ECWMLZEP 3-134, 3-69<br />

ECWMLZFBUS 3-134, 3-69<br />

ECWMT3BC1 3-134<br />

ECWMT3BC2 3-134<br />

ECWMT3BC3 3-134<br />

ED21B015 7-111<br />

ED21B020 7-111<br />

ED21B025 7-111<br />

ED21B030 7-111<br />

ED21B035 7-111<br />

ED21B040n 7-111<br />

ED21B045 7-111<br />

ED21B050 7-111<br />

ED21B060 7-111<br />

ED21B070 7-111<br />

ED21B080 7-111<br />

ED21B090 7-111<br />

ED21B100 7-111<br />

ED22B015 7-111<br />

ED22B020 7-111<br />

ED22B025 7-111<br />

ED22B030 7-111<br />

ED22B035 7-111<br />

ED22B040 7-111<br />

ED22B045 7-111<br />

ED22B050 7-111<br />

ED22B060 7-111<br />

ED22B070 7-111<br />

ED22B080 7-111<br />

ED22B090 7-111<br />

ED22B100 7-111<br />

ED22S100A 7-146<br />

ED23B015 7-111<br />

ED23B020 7-111<br />

ED23B025 7-111<br />

ED23B030 7-111<br />

ED23B035 7-111<br />

ED23B040 7-111<br />

ED23B045 7-111<br />

ED23B050 7-111<br />

ED23B060 7-111<br />

ED23B070 7-111<br />

ED23B080 7-111<br />

ED23B090 7-111<br />

ED23B100 7-111<br />

ED23S100A 7-146<br />

ED2HPL 13-19, 7-160<br />

ED41B015d 7-111<br />

ED41B020 7-111<br />

ED41B025 7-111<br />

ED41B030 7-111<br />

ED41B035 7-111<br />

ED41B040 7-111<br />

ED41B045 7-111<br />

ED41B050 7-111<br />

ED41B060 7-111<br />

ED41B070 7-111<br />

ED41B080 7-111<br />

ED41B090 7-111<br />

ED41B100 7-111<br />

ED41B110 7-111<br />

ED42B020 7-111<br />

ED42B025 7-111<br />

ED42B030 7-111<br />

ED42B035 7-111<br />

ED42B040 7-111<br />

ED42B045 7-111<br />

ED42B050 7-111<br />

ED42B060 7-111<br />

ED42B070 7-111<br />

ED42B080 7-111<br />

ED42B090 7-111<br />

ED42B100 7-111<br />

ED42B110 7-111<br />

ED42B125 7-111<br />

ED42S100A 7-146<br />

ED42S125A 7-146<br />

ED43B015 7-111, 7-142<br />

ED43B020 7-111<br />

ED43B025 7-111<br />

ED43B030 7-111, 7-142<br />

ED43B035 7-111<br />

ED43B040 7-111, 7-142<br />

ED43B045 7-111<br />

ED43B050 7-111, 7-142<br />

ED43B060 7-111<br />

ED43B070 7-111<br />

ED43B080 7-111<br />

ED43B090 7-111<br />

ED43B100 7-111<br />

ED43B110 7-111<br />

ED43B125 7-111<br />

ED43S100A 7-146<br />

ED43S125A 7-146<br />

ED6 6-12, 7-122<br />

ED61B015 7-111<br />

ED61B020 7-111<br />

ED61B025 7-111<br />

ED61B030 7-111<br />

ED61B035 7-111<br />

ED61B040 7-111<br />

ED61B045 7-111<br />

ED61B050 7-111<br />

ED61B060 7-111<br />

ED61B070 7-111<br />

ED61B080 7-111<br />

ED61B090 7-111<br />

ED61B100 7-111<br />

ED62B020 7-111<br />

ED62B025 7-111<br />

ED62B030 7-111<br />

ED62S100A 7-146<br />

ED63A001 7-140, 7-141, 7-143<br />

ED63A002 7-140, 7-141, 7-143<br />

ED63A003 7-140, 7-141, 7-143<br />

ED63A005 7-140, 7-141, 7-143<br />

ED63A010 7-140, 7-141, 7-143<br />

ED63A025 7-140, 7-141, 7-143<br />

ED63A030 7-140, 7-141, 7-143<br />

ED63A040 7-140, 7-141, 7-143<br />

ED63A050 7-140, 7-141, 7-143<br />

ED63A100 7-140, 7-141, 7-143<br />

ED63A125 7-140, 7-141, 7-143<br />

ED63B015 7-142<br />

ED63B020 7-111, 7-142<br />

ED63B025 7-111<br />

ED63B030 7-111, 7-142<br />

ED63B035 7-111, 7-142<br />

ED63B040 7-111<br />

ED63B045 7-111<br />

ED63B050 7-111, 7-142<br />

ED63B060 7-111<br />

ED63B070 7-111<br />

ED63B080 7-111<br />

ED63B090 7-111<br />

ED63B100 7-111<br />

ED63B110 7-111<br />

ED63B125 7-111<br />

ED63D015L 7-111<br />

ED63D020L 7-111<br />

ED63D025L 7-111<br />

ED63D030L 7-111<br />

ED63D035L 7-111<br />

ED63D040L 7-111<br />

ED63D045L 7-111<br />

ED63D050L 7-111<br />

ED63D060L 7-111<br />

ED63S100A 7-146<br />

ED63S125A 7-146<br />

ED6SS4 6-12, 7-111<br />

EE 7-118<br />

EGK 11-11, 11-23, 11-38, 11-49<br />

EJP302 15-80<br />

EJP304 15-80<br />

EJP306 15-80<br />

EJP308 15-80<br />

EJP310 15-80<br />

EJP313 15-80<br />

EJP316 15-80<br />

EJP4024 15-80<br />

EJP4044 15-80<br />

EJP4064 15-80<br />

EJP4084 15-80<br />

EJP4104 15-80<br />

ELBT118 3-102<br />

ELBT318 3-102<br />

EMC5J 2-51, 2-77<br />

EMOPL120MN 7-164<br />

EMOPL240MN 7-164<br />

EPSP18V 7-120, 7-124, 7-127, 7-131,<br />

7-135, 7-138, 7-216, 7-217<br />

ETB302 15-80<br />

ETB304 15-80<br />

ETB306 15-80<br />

ETB308 15-80<br />

ETB310 15-80<br />

ETB313 15-80<br />

ETB316 15-80<br />

ETB4024 15-80<br />

ETB4044 15-80<br />

ETB4064 15-80<br />

ETB4084 15-80<br />

ETB4101 15-80<br />

EWK1 11-11, 11-23, 11-38<br />

EWK2 11-11, 11-23, 11-38, 11-49<br />

EX11 7-160<br />

F26B 11-38<br />

F32B 11-38<br />

F353SSDTK 4-31, 4-33<br />

F354SSDTK 4-31, 4-33<br />

F355SSDTK 4-31, 4-33<br />

F38B 11-38<br />

F44B 11-38<br />

F50B 11-38<br />

F56B 11-38<br />

F60 11-82<br />

F602 11-77, 5-26<br />

F602D 11-91, 5-26<br />

F6150D 11-91<br />

F6162D 11-91, 13-26, 5-27<br />

F62B 11-38<br />

F657 11-77, 5-26<br />

F657D 11-91, 5-26<br />

F671 11-77, 5-26<br />

F671D 11-91, 5-26<br />

F672 11-77, 5-26<br />

F672D 11-91, 5-26<br />

F68B 11-38<br />

F6N12 6-13, 7-114<br />

F6N1F 6-8<br />

F6N1S 6-8, 7-114<br />

F6N3R 6-10, 7-114<br />

F6RH1 7-162<br />

F6RHV9 7-162<br />

F74B 11-38<br />

F75 11-82<br />

F860 11-96<br />

F875 11-96<br />

F890 11-96<br />

F90 11-82<br />

FBCD3 7-210<br />

FBCF3 7-210<br />

FBCJ3 7-211<br />

FBCL3 7-211<br />

FBCM3 7-211<br />

FCJK603 5-12<br />

FCJK606 5-12<br />

FCK203 5-12<br />

FCK206 5-12<br />

FCK606 5-12<br />

FCK610 5-12<br />

FCK620 5-12<br />

FCRK203 5-12<br />

FCRK206 5-12<br />

FCRK606 5-12<br />

FD62B070 7-114, 7-143<br />

FD62B080 7-114, 7-143<br />

FD62B090 7-114, 7-143<br />

FD62B100 7-114, 7-143<br />

FD62B110 7-114, 7-143<br />

FD62B125 7-114, 7-143<br />

FD62B150 7-114, 7-143<br />

FD62B175 7-114, 7-143<br />

FD62B200 7-114, 7-143<br />

FD62B225 7-114, 7-143<br />

FD62B250 7-114, 7-143<br />

FD62F250 7-114<br />

FD62T070 7-114, 7-115<br />

FD62T080 7-114, 7-115<br />

FD62T090 7-114, 7-115<br />

FD62T100 7-114, 7-115<br />

FD62T110 7-114, 7-115<br />

FD62T125 7-114, 7-115<br />

FD62T150 7-114, 7-115<br />

FD62T175 7-114, 7-115<br />

FD62T200 7-114, 7-115<br />

FD62T225 7-114, 7-115<br />

FD62T250 7-114, 7-115<br />

FD63B070 7-114, 7-143<br />

FD63B080 7-114, 7-143<br />

FD63B090 7-114, 7-143<br />

FD63B100 7-114, 7-143<br />

FD63B110 7-114, 7-143<br />

FD63B125 7-114, 7-143<br />

FD63B150 7-114, 7-143<br />

FD63B175 7-114, 7-142, 7-143<br />

FD63B200 7-114, 7-143<br />

FD63B225 7-114, 7-143<br />

FD63B250 7-114, 7-142, 7-143<br />

FD63F250 7-114<br />

FD63T070 7-114, 7-115<br />

FD63T080 7-114, 7-115<br />

FD63T090 7-115<br />

FD63T100 7-114, 7-115<br />

FD63T110 7-114, 7-115<br />

FD63T125 7-114, 7-115<br />

FD63T150 7-114, 7-115<br />

FD63T175 7-114, 7-115<br />

FD63T200 7-114, 7-115<br />

FD63T225 7-114, 7-115<br />

FD63T250 7-114, 7-115<br />

FD6HB1 7-160<br />

FD6PL1 7-160<br />

FD6SS4 6-12, 7-114<br />

FDFBEL 7-163<br />

FDFBEL4 7-163<br />

FDFBER 7-163<br />

FDFBER4 7-163<br />

FDFBFL 7-163<br />

FDFBFL4 7-163<br />

FDFBFR 7-163<br />

FDFBFR4 7-163<br />

FDFS06L 5-13<br />

FDFS06R 5-13<br />

FDFS20L 5-13<br />

FDFS20R 5-13<br />

FDH10 5-13<br />

FDH20 5-13<br />

FDS06L 5-13<br />

FDS06R 5-13<br />

FDS20L 5-13<br />

FDS20R 5-13<br />

FXD63B100 7-142<br />

FE100 5-13<br />

FE200 5-13<br />

FEP302 15-80<br />

FEP304 15-80<br />

FEP306 15-80<br />

FEP308 15-80<br />

FEP310 15-80<br />

FEP313 15-80<br />

FEP316 15-80<br />

FEP4024 15-80<br />

FEP4044 15-80<br />

FEP4064 15-80<br />

FEP4084 15-80<br />

FEP4104 15-80<br />

FG6N12 6-13<br />

FG6N1F 6-9<br />

FG6N1S 6-9<br />

FG6N3R 6-11<br />

FG6N4X 6-12<br />

FG6N4X316 6-12<br />

FHOE036 7-163<br />

FHOEBO 7-163<br />

HCQ62 4-21, 5-13, 5-8, 5-9, 7-163<br />

HCQ64 4-21, 5-8, 5-9, 7-163<br />

FHOEC060 7-163<br />

FHOEC072 7-163<br />

FHOEC096 7-163<br />

FHOEC120 7-163<br />

FHOEC144 7-163<br />

FHOF036 7-163<br />

FHOFBO 7-163<br />

FHOFC036 7-163<br />

FHOFC048 7-163<br />

FHOFC060 7-163<br />

FHOFC072 7-163<br />

FHOFC096 7-163<br />

FHOFC120 7-163<br />

FHOFC144 7-163<br />

FHOH 7-163<br />

FHOH4 7-163<br />

FHOHN 7-163<br />

FHOHN4 7-163<br />

FHOHS 5-13<br />

FHOJ036 7-163<br />

FHOJBO 7-163<br />

FHOJC036 5-13, 7-163<br />

I<br />

PRODUCT<br />

INDEX<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog I-13


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

I<br />

PRODUCT<br />

INDEX<br />

FHOJC048 7-163<br />

FHOJC060 7-163<br />

FHOJC072 7-163<br />

FHOJC096 7-163<br />

FHOJC120 7-163<br />

FHOJC144 7-163<br />

FHOLM036 7-163<br />

FHOLMBO 7-163<br />

FHON048 7-163<br />

FHONBO 7-163<br />

FHONC048 7-163<br />

FHONC060 7-163<br />

FHONC072 7-163<br />

FHONC096 7-163<br />

FHONC120 7-163<br />

FHONC144 7-163<br />

FHOS06036L 5-13<br />

FHOS06036R 5-13<br />

FHOS06L 5-13<br />

FHOS06R 5-13<br />

FHOS20036L 5-13<br />

FHOS20036R 5-13<br />

FHOS20L 5-13<br />

FHOS20R 5-13<br />

FHVF3R 7-208<br />

FHVF3RB 7-208<br />

FHVF4X 7-208<br />

FHVF4XB 7-208<br />

FHVL3R 7-208<br />

FHVL3RB 7-208<br />

FHVL4X 7-208<br />

FHVL4XB 7-208<br />

FMHOS 7-162<br />

FMPG1 7-161<br />

FMPG2 7-161<br />

FMPG3 7-161<br />

FP9508 1-48, 7-158<br />

FP9555 1-48, 7-158<br />

FP9556 1-48, 7-158<br />

FR325DTK 4-31, 4-33<br />

FR326DTK 4-31, 4-33<br />

FR355DTK 4-31, 4-33<br />

FS060 1-51, 10-7<br />

FS100 1-51, 10-7<br />

FS140 1-51, 10-7<br />

FSCATV 1-52<br />

FSPHONE 1-52<br />

FSPHONE4X 1-52<br />

FXD62B070 7-114, 7-143<br />

FXD62B080 7-114, 7-143<br />

FXD62B090 7-114, 7-143<br />

FXD62B100 7-114, 7-143<br />

FXD62B110 7-114, 7-143<br />

FXD62B125 7-114, 7-143<br />

FXD62B150 7-114, 7-143<br />

FXD62B175 7-114, 7-143<br />

FXD62B200 7-114, 7-143<br />

FXD62B225 7-114, 7-143<br />

FXD62B250 7-114, 7-143<br />

FXD62S250A 7-146<br />

FXD63A150 7-140, 7-141, 7-143<br />

FXD63A250 7-140, 7-141, 7-143<br />

FXD63B060 7-142<br />

FXD63B070 7-114, 7-142, 7-143<br />

FXD63B080 7-114, 7-143<br />

FXD63B090 7-114, 7-142, 7-143<br />

FXD63B100 7-114, 7-142, 7-143<br />

FXD63B110 7-114, 7-143<br />

FXD63B125 7-114, 7-142, 7-143<br />

FXD63B150 7-114, 7-142, 7-143<br />

FXD63B175 7-114, 7-142, 7-143<br />

FXD63B200 7-114, 7-142, 7-143<br />

FXD63B225 7-114, 7-142, 7-143<br />

FXD63B250 7-114, 7-143<br />

FXD63H150 7-140, 7-143<br />

FXD63L150 7-140, 7-141, 7-143<br />

FXD63S250A 7-146<br />

G3042B1200GEN 1-17<br />

G3042L1225GEN 1-17<br />

G4254B1200GEN 1-17<br />

G4254L1225GEN 1-17<br />

GF01ED60 7-113<br />

GF01ED60B0 7-113<br />

GF01ED60BC 7-113<br />

GF01ED65 7-113<br />

GF01ED65B0 7-113<br />

GF01ED65BC 7-113<br />

GF221NA 4-8<br />

GF221NRA 4-8<br />

GF222NA 4-8<br />

GF222NRA 4-8<br />

GF223N 4-8<br />

GF223NR 4-8<br />

GF224N 4-8<br />

GF224NR 4-8<br />

GF321NA 4-8<br />

GF321NRA 4-8<br />

GF322NA 4-8<br />

GF322NRA 4-8<br />

GF323N 4-8<br />

GF323NR 4-8<br />

GF324N 4-8<br />

GF324NR 4-8<br />

GF325NA 4-8<br />

GF325NRA 4-8<br />

GF326NA 4-8<br />

GF326NRA 4-8<br />

GG0121FN 6-8<br />

GG0121SN 6-8<br />

GG0123RN 6-10<br />

GG0124XN 6-12<br />

GH223 4-36<br />

GH24 4-36<br />

GMBC1 3-138<br />

GMBC2 3-138<br />

GNF221A 4-8<br />

GNF221RA 4-8<br />

GNF222A 4-8<br />

GNF222RA 4-8<br />

GNF321A 4-8<br />

GNF321LA 4-8<br />

GNF321RA 4-8<br />

GNF321RLA 4-8<br />

GNF322A 4-8<br />

GNF322RA 4-8<br />

GNF323 4-8<br />

GNF323R 4-8<br />

GNF324 4-8<br />

GNF324R 4-8<br />

GNF325A 4-8<br />

GNF326A 4-8<br />

GSGK60 4-35, 5-6<br />

H35815-2 2-51, 2-77<br />

H55890 2-25<br />

H56476 2-25, 3-110, 3-137<br />

H56732 2-25, 3-110, 3-137<br />

H56732-M 3-110, 3-137<br />

H58022 2-25<br />

H58852 2-25<br />

H59676 2-25<br />

H60162 3-110, 3-137<br />

H68752-1 3-110, 3-137<br />

HA161234 4-21, 4-32, 5-10<br />

HA165678 4-21, 4-32, 5-10<br />

HA261234 4-21, 4-32, 5-10<br />

HA265678 4-21, 4-32, 5-10<br />

HA361234 4-21, 5-10<br />

HA365678 4-21, 5-10<br />

HAS1 7-163<br />

HB1B015 7-38<br />

HB1B020 7-38<br />

HB1B025 7-38<br />

HB1B030 7-38<br />

HB1B035 7-38<br />

HB1B040 7-38<br />

HB1B045 7-38<br />

HB1B050 7-38<br />

HB1B060 7-38<br />

HB1B070 7-38<br />

HB2B015 7-38<br />

HB2B020n 7-38<br />

HB2B025 7-38<br />

HB2B030 7-38<br />

HB2B035 7-38<br />

HB2B040 7-38<br />

HB2B045 7-38<br />

HB2B050 7-38<br />

HB2B060 7-38<br />

HB2B070 7-38<br />

HB2B080 7-38<br />

HB2B090 7-38<br />

HB2B100 7-38<br />

HB2B110 7-38<br />

HB2B125 7-38<br />

HB3B015 7-38<br />

HB3B020 7-38<br />

HB3B025 7-38<br />

HB3B030 7-38<br />

HB3B035 7-38<br />

HB3B040 7-38<br />

HB3B045 7-38<br />

HB3B050 7-38<br />

HB3B060 7-38<br />

HB3B070 7-38<br />

HB3B080 7-38<br />

HB3B090 7-38<br />

HB3B100 7-38<br />

HBB21 4-36<br />

HBB22 4-36<br />

HBB612 4-36<br />

HBB62 4-36<br />

HBB63 4-36<br />

HBB64 4-36<br />

HBB656 4-36<br />

HBB67A 4-36<br />

HBB68 4-36<br />

HBDF 7-214<br />

HBDL 7-215<br />

HBDM 7-215<br />

HBDP 7-215<br />

HBLQR 13-19, 7-160, 7-41<br />

HCL612 4-22<br />

HCL623 4-22<br />

HCL65678 4-22<br />

HCM65A 4-22<br />

HCM66A 4-22<br />

HCP327HT 5-27<br />

HCP327VT 5-27<br />

HCP328HT 5-27<br />

HCP328VT 5-27<br />

HCP367H 5-27<br />

HCP367HJ400 5-27<br />

HCP367HJ600 5-27<br />

HCP367V 5-27<br />

HCP367VJ400 5-27<br />

HCP367VJ600 5-27<br />

HCP368H 5-27<br />

HCP368V 5-27<br />

HCPHK 5-27<br />

HCPST120 5-27<br />

HCPST240 5-27<br />

HCPST277 5-27<br />

HCPST480 5-27<br />

HCRXA 2-77<br />

HCU656A 4-21<br />

HDK2B050L 7-176<br />

HDK2B060L 7-176<br />

HDK2B070L 7-176<br />

HDK2B080L 7-176<br />

HDK2B090L 7-176<br />

HDK2B100L 7-176<br />

HDK2B110L 7-176<br />

HDK2B125L 7-176<br />

HDK2B150L 7-176<br />

HDK3A060L 7-177<br />

HDK3A100L 7-177<br />

HDK3A150L 7-177<br />

HDK3B050L 7-176<br />

HDK3B060L 7-176<br />

HDK3B070L 7-176<br />

HDK3B080L 7-176<br />

HDK3B090L 7-176<br />

HDK3B100L 7-176<br />

HDK3B110L 7-176<br />

HDK3B125L 7-176<br />

HDK3B150L 7-176<br />

HDK3G060L 7-177<br />

HDK3G100L 7-177<br />

HDK3G150L 7-177<br />

HDK3K060L 7-177<br />

HDK3K100L 7-177<br />

HDK3K150L 7-177<br />

HDK3R060L 7-177<br />

HDK3R100L 7-177<br />

HDK3R150L 7-177<br />

HDK3T060L 7-177<br />

HDK3T100L 7-177<br />

HDK3T150L 7-177<br />

HDK3V060L 7-177<br />

HDK3V100L 7-177<br />

HDK3V150L 7-177<br />

HDK3W060L 7-177<br />

HDK3W100L 7-177<br />

HDK3W150L 7-177<br />

HDP3H150L 7-203<br />

HDP3L150L 7-203<br />

HDP3M150L 7-203<br />

HDR2S150 7-202<br />

HDR3S150 7-202<br />

HED41B015 7-112<br />

HED41B020 7-112<br />

HED41B025 7-112<br />

HED41B030 7-112<br />

HED41B035 7-112<br />

HED41B040 7-112<br />

HED41B045 7-112<br />

HED41B050 7-112<br />

HED41B060 7-112<br />

HED41B070 7-112<br />

HED41B080 7-112<br />

HED41B090 7-112<br />

HED41B100 7-112<br />

HED42B015 7-112<br />

HED42B020 7-112<br />

HED42B025 7-112<br />

HED42B030 7-112<br />

HED42B035 7-112<br />

HED42B040 7-112<br />

HED42B045 7-112<br />

HED42B050 7-112<br />

HED42B060 7-112<br />

HED42B070 7-112<br />

HED42B080 7-112<br />

HED42B090 7-112<br />

HED42B100 7-112<br />

HED42B110 7-112<br />

HED42B125 7-112<br />

HED43B015 7-112<br />

HED43B020 7-112<br />

HED43B025 7-112<br />

HED43B030 7-112<br />

HED43B035 7-112<br />

HED43B040 7-112<br />

HED43B045 7-112<br />

HED43B050 7-112<br />

HED43B060 7-112<br />

HED43B070 7-112<br />

HED43B080 7-112<br />

HED43B090 7-112<br />

HED43B100 7-112<br />

HED43B110 7-112<br />

HED43B125 7-112<br />

HF1104NPV 4-19<br />

HF1104NRPV 4-19<br />

HF165NRPV 4-19<br />

HF166NRPV 4-19<br />

HF221J 4-10<br />

HF221N 4-10<br />

HF221NR 4-10<br />

HF221S 4-10<br />

HF222J 4-10<br />

HF222N 4-10<br />

HF222NR 4-10<br />

HF222S 4-10<br />

HF223J 4-10<br />

HF223N 4-10<br />

HF223NR 4-10<br />

HF223S 4-10<br />

HF224J 4-10<br />

HF224N 4-10<br />

HF224NR 4-10<br />

HF224S 4-10<br />

HF225NA 4-10<br />

HF225NRA 4-10<br />

HF226NA 4-10<br />

HF226NRA 4-10<br />

HF227N 4-10<br />

HF227NR 4-10<br />

HF228N 4-10<br />

HF228NR 4-10<br />

HF261 4-11<br />

HF261J 4-11<br />

HF261R 4-11<br />

HF261S 4-11<br />

HF262 4-11<br />

HF262J 4-11<br />

HF262R 4-11<br />

HF262S 4-11<br />

HF263 4-11<br />

HF263J 4-11<br />

HF263R 4-11<br />

HF263S 4-11<br />

HF321J 4-10<br />

HF321JCH 4-17<br />

HF321N 4-10<br />

HF321NR 4-10<br />

HF321NX 4-18, 4-29<br />

HF321S 4-10<br />

HF321SCH 4-17<br />

HF321SS 4-18<br />

HF322J 4-10<br />

HF322JCH 4-17<br />

HF322JPN 4-17<br />

HF322N 4-10<br />

HF322NR 4-10<br />

HF322NX 4-18, 4-29<br />

HF322S 4-10<br />

HF322SCH 4-17<br />

HF322SS 4-18<br />

HF323J 4-10<br />

HF323JCH 4-17<br />

HF323N 4-10<br />

HF323NR 4-10<br />

HF323S 4-10<br />

HF323SCH 4-17<br />

HF323SS 4-18<br />

HF324J 4-10<br />

HF324N 4-10<br />

HF324NR 4-10<br />

HF324S 4-10<br />

HF324SS 4-18<br />

HF325JA 4-10<br />

HF325NA 4-10<br />

HF325NRA 4-10<br />

HF325SA 4-10<br />

HF325SSA 4-10<br />

HF326JA 4-10<br />

HF326NA 4-10<br />

HF326NRA 4-10<br />

HF326SA 4-10<br />

HF326SSA 4-10<br />

HF327J 4-10<br />

HF327N 4-10<br />

HF327NR 4-10<br />

HF327S 4-10<br />

HF328N 4-10<br />

HF328NR 4-10<br />

HF361 4-11<br />

HF361J 4-11<br />

HF361JCH 4-17<br />

HF361JCHW 4-17<br />

HF361JPN 4-17<br />

HF361JW 4-13<br />

HF361L 4-11<br />

HF361N 4-11<br />

HF361NR 4-11<br />

HF361NX 4-18, 4-29<br />

HF361PV 4-19<br />

HF361PVPG 4-19<br />

HF361R 4-11<br />

HF361RL 4-11<br />

HF361RPV 4-19<br />

HF361RPVPG 4-19<br />

HF361RW 4-13<br />

HF361S 4-11<br />

HF361SCH 4-17<br />

HF361SCHW 4-17<br />

HF361SPN 4-17<br />

HF361SS 4-18<br />

HF361SSW 4-18<br />

HF361SW 4-13<br />

HF362 4-11<br />

HF362J 4-11<br />

HF362JCH 4-17<br />

HF362JCHW 4-17<br />

HF362JPN 4-17<br />

HF362JW 4-13<br />

HF362N 4-11<br />

HF362NR 4-11<br />

HF362NX 4-18, 4-29<br />

HF362PV 4-19<br />

HF362PVPG 4-19<br />

HF362R 4-11<br />

HF362RL 4-11<br />

HF362RPV 4-19<br />

HF362RPVPG 4-19<br />

HF362RW 4-13<br />

HF362S 4-11<br />

HF362SCH 4-17<br />

HF362SCHW 4-17<br />

HF362SPN 4-17<br />

HF362SS 4-18<br />

HF362SSW 4-18<br />

HF362SW 4-13<br />

HF363 4-11<br />

HF363J 4-11<br />

HF363JCH 4-17<br />

HF363JCHW 4-17<br />

HF363JW 4-13<br />

HF363N 4-11<br />

I-14<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

HF363NR 4-11<br />

HF363NX 4-18, 4-29<br />

HF363PV 4-19<br />

HF363PVPG 4-19<br />

HF363R 4-11<br />

HF363RPV 4-19<br />

HF363RPVPG 4-19<br />

HF363S 4-11<br />

HF363SCH 4-17<br />

HF363SCHW 4-17<br />

HF363SS 4-18<br />

HF363SSW 4-18<br />

HF363SW 4-13<br />

HF364 4-11<br />

HF364J 4-11<br />

HF364JW 4-13<br />

HF364N 4-11<br />

HF364NR 4-11<br />

HF364NX 4-18, 4-29<br />

HF364PV 4-19<br />

HF364PVPG 4-19<br />

HF364R 4-11<br />

HF364RPV 4-19<br />

HF364RPVPG 4-19<br />

HF364S 4-11<br />

HF364SS 4-18<br />

HF364SSW 4-18<br />

HF364SW 4-13<br />

HF365A 4-11<br />

HF365JA 4-11<br />

HF365JWA 4-13<br />

HF365NA 4-11<br />

HF365NRA 4-11<br />

HF365RA 4-11<br />

HF365SA 4-11<br />

HF365SSA 4-11<br />

HF365SSWA 4-13<br />

HF365SWA 4-13<br />

HF366A 4-11<br />

HF366JA 4-11<br />

HF366JWA 4-13<br />

HF366NA 4-11<br />

HF366NRA 4-11<br />

HF366RA 4-11<br />

HF366SA 4-11<br />

HF366SSA 4-11<br />

HF367 4-11<br />

HF367J 4-11<br />

HF367N 4-11<br />

HF367NR 4-11<br />

HF367R 4-11<br />

HF367S 4-11<br />

HF368 4-11<br />

HF368J 4-11<br />

HF368N 4-11<br />

HF368NR 4-11<br />

HF368R 4-11<br />

HF368S 4-11<br />

HF461 4-16, 4-30<br />

HF461J 4-16, 4-30<br />

HF462 4-16, 4-30<br />

HF462J 4-16, 4-30<br />

HF463 4-16, 4-30<br />

HF463J 4-16, 4-30<br />

HF464 4-16, 4-30<br />

HF464J 4-16, 4-30<br />

HF63CX 4-35, 5-6<br />

HF661J 4-16, 4-30<br />

HF661S 4-16, 4-30<br />

HF662J 4-16, 4-30<br />

HF662S 4-16, 4-30<br />

HF663J 4-16, 4-30<br />

HF663S 4-16, 4-30<br />

HF664J 4-16, 4-30<br />

HF664S 4-16, 4-30<br />

HFB21 4-36<br />

HFB22 4-36<br />

HFB612 4-36<br />

HFB62 4-36<br />

HFB63 4-36<br />

HFB64 4-36<br />

HFB65 4-36<br />

HFB66 4-36<br />

HFB67A 4-36<br />

HFB68 4-36<br />

HFC3B100 7-204<br />

HFC3B150 7-204<br />

HFC3B175 7-204<br />

HFC3B200 7-204<br />

HFC3B250 7-204<br />

HFD62B070 7-115, 7-143<br />

HFD62B080 7-115, 7-143<br />

HFD62B090 7-115, 7-143<br />

HFD62B100 7-115, 7-143<br />

HFD62B110 7-115, 7-143<br />

HFD62B125 7-115, 7-143<br />

HFD62B150 7-115, 7-143<br />

HFD62B175 7-115, 7-143<br />

HFD62B200 7-115, 7-143<br />

HFD62B225 7-115, 7-143<br />

HFD62B250 7-115, 7-143<br />

HFD62F250 7-115<br />

HFD63B070 7-115, 7-143<br />

HFD63B080 7-115, 7-143<br />

HFD63B090 7-115, 7-143<br />

HFD63B100 7-115, 7-143<br />

HFD63B110 7-115, 7-143<br />

HFD63B125 7-115, 7-143<br />

HFD63B150 7-115, 7-143<br />

HFD63B175 7-115, 7-143<br />

HFD63B200 7-115, 7-143<br />

HFD63B225 7-115, 7-143<br />

HFD63B250 7-115, 7-143<br />

HFD63F250 7-115<br />

HFK2B100L 7-180<br />

HFK2B110L 7-180<br />

HFK2B125L 7-180<br />

HFK2B150L 7-180<br />

HFK2B175L 7-180<br />

HFK2B200L 7-180<br />

HFK2B225L 7-180<br />

HFK2B250L 7-180<br />

HFK3A100L 7-181<br />

HFK3A150L 7-181<br />

HFK3A250L 7-181<br />

HFK3B100L 7-180<br />

HFK3B110L 7-180<br />

HFK3B125L 7-180<br />

HFK3B150L 7-180<br />

HFK3B175L 7-180<br />

HFK3B200L 7-180<br />

HFK3B225L 7-180<br />

HFK3B250L 7-180<br />

HFK3G100L 7-181<br />

HFK3G150L 7-181<br />

HFK3G250L 7-181<br />

HFK3K100L 7-181<br />

HFK3K150L 7-181<br />

HFK3K250L 7-181<br />

HFK3R100L 7-181<br />

HFK3R150L 7-181<br />

HFK3R250L 7-181<br />

HFK3T100L 7-181<br />

HFK3T150L 7-181<br />

HFK3T250L 7-181<br />

HFK3V100L 7-181<br />

HFK3V150L 7-181<br />

HFK3V250L 7-181<br />

HFK3W100L 7-181<br />

HFK3W150L 7-181<br />

HFK3W250L 7-181<br />

HFP3H250L 7-203<br />

HFP3L250L 7-203<br />

HFP3M250L 7-203<br />

HFR2S250 7-202<br />

HFR3S250 7-202<br />

HFXD62S250A 7-146<br />

HFXD63S250A 7-146<br />

HG261234 4-21<br />

HG2656A 4-21<br />

HG61234 4-21, 4-32, 5-10<br />

HG656 4-32, 5-10<br />

HG656A 4-21<br />

HG678 4-21, 4-32<br />

HGB1B015B 7-33<br />

HGB1B020B 7-33<br />

HGB1B025B 7-33<br />

HGB1B030B 7-33<br />

HGB1B035B 7-33<br />

HGB1B040B 7-33<br />

HGB1B045B 7-33<br />

HGB1B050B 7-33<br />

HGB1B060B 7-33<br />

HGB1B070B 7-33<br />

HGB1B080B 7-33<br />

HGB1B090B 7-33<br />

HGB1B100B 7-33<br />

HGB1B110B 7-33<br />

HGB1B125B 7-33<br />

HGB1K015B 7-34<br />

HGB1K020B 7-34<br />

HGB1K025B 7-34<br />

HGB1K030B 7-34<br />

HGB1K035B 7-34<br />

HGB1K040B 7-34<br />

HGB1K045B 7-34<br />

HGB1K050B 7-34<br />

HGB1K060B 7-34<br />

HGB1K070B 7-34<br />

HGB1K080B 7-34<br />

HGB1K090B 7-34<br />

HGB1K100B 7-34<br />

HGB1K110B 7-34<br />

HGB1K125B 7-34<br />

HGB2B015B 7-33<br />

HGB2B020B 7-33<br />

HGB2B025B 7-33<br />

HGB2B030B 7-33<br />

HGB2B035B 7-33<br />

HGB2B040B 7-33<br />

HGB2B045B 7-33<br />

HGB2B050B 7-33<br />

HGB2B060B 7-33<br />

HGB2B070B 7-33<br />

HGB2B080B 7-33<br />

HGB2B090B 7-33<br />

HGB2B100B 7-33<br />

HGB2B110B 7-33<br />

HGB2B125B 7-33<br />

HGB2K015B 7-34<br />

HGB2K020B 7-34<br />

HGB2K025B 7-34<br />

HGB2K030B 7-34<br />

HGB2K035B 7-34<br />

HGB2K040B 7-34<br />

HGB2K045B 7-34<br />

HGB2K050B 7-34<br />

HGB2K060B 7-34<br />

HGB2K070B 7-34<br />

HGB2K080B 7-34<br />

HGB2K090B 7-34<br />

HGB2K100B 7-34<br />

HGB2K110B 7-34<br />

HGB2K125B 7-34<br />

HGB3B015B 7-33<br />

HGB3B020B 7-33<br />

HGB3B025B 7-33<br />

HGB3B030B 7-33<br />

HGB3B035B 7-33<br />

HGB3B040B 7-33<br />

HGB3B045B 7-33<br />

HGB3B050B 7-33<br />

HGB3B060B 7-33<br />

HGB3B070B 7-33<br />

HGB3B080B 7-33<br />

HGB3B090B 7-33<br />

HGB3B100B 7-33<br />

HGB3B110B 7-33<br />

HGB3B125B 7-33<br />

HGB3K015B 7-34<br />

HGB3K020B 7-34<br />

HGB3K025B 7-34<br />

HGB3K030B 7-34<br />

HGB3K035B 7-34<br />

HGB3K040B 7-34<br />

HGB3K045B 7-34<br />

HGB3K050B 7-34<br />

HGB3K060B 7-34<br />

HGB3K070B 7-34<br />

HGB3K080B 7-34<br />

HGB3K090B 7-34<br />

HGB3K100B 7-34<br />

HGB3K110B 7-34<br />

HGB3K125B 7-34<br />

HGG1B015L 7-43<br />

HGG1B020L 7-43<br />

HGG1B025L 7-43<br />

HGG1B030L 7-43<br />

HGG1B035L 7-43<br />

HGG1B040L 7-43<br />

HGG1B045L 7-43<br />

HGG1B050L 7-43<br />

HGG1B060L 7-43<br />

HGG1B070L 7-43<br />

HGG1B080L 7-43<br />

HGG1B090L 7-43<br />

HGG1B100L 7-43<br />

HGG1B110L 7-43<br />

HGG1B125L 7-43<br />

HGG2B015L 7-43<br />

HGG2B020L 7-43<br />

HGG2B025L 7-43<br />

HGG2B030L 7-43<br />

HGG2B035L 7-43<br />

HGG2B040L 7-43<br />

HGG2B045L 7-43<br />

HGG2B050L 7-43<br />

HGG2B060L 7-43<br />

HGG2B070L 7-43<br />

HGG2B080L 7-43<br />

HGG2B090L 7-43<br />

HGG2B100L 7-43<br />

HGG2B110L 7-43<br />

HGG2B125L 7-43<br />

HGG3B015L 7-43<br />

HGG3B020L 7-43<br />

HGG3B025L 7-43<br />

HGG3B030L 7-43<br />

HGG3B035L 7-43<br />

HGG3B040L 7-43<br />

HGG3B045L 7-43<br />

HGG3B050L 7-43<br />

HGG3B060L 7-43<br />

HGG3B070L 7-43<br />

HGG3B080L 7-43<br />

HGG3B090L 7-43<br />

HGG3B100L 7-43<br />

HGG3B110L 7-43<br />

HGG3B125L 7-43<br />

HH6123 4-36<br />

HH64 4-36<br />

HH65678 4-36<br />

HH68 4-36<br />

HHD61234 4-32<br />

HHD61234S 4-32<br />

HHD656 4-32<br />

HHED63B015A 7-112<br />

HHED63B020 7-112<br />

HHED63B025 7-112<br />

HHED63B030 7-112<br />

HHED63B035 7-112<br />

HHED63B040 7-112<br />

HHED63B045 7-112<br />

HHED63B050 7-112<br />

HHFD63B070 7-115, 7-143<br />

HHFD63B080 7-115<br />

HHFD63B090 7-115, 7-143<br />

HHFD63B100 7-115, 7-143<br />

HHFD63B110 7-115, 7-143<br />

HHFD63B125 7-115, 7-143<br />

HHFD63B150 7-115, 7-143<br />

HHFD63B175 7-115, 7-143<br />

HHFD63B200 7-115, 7-143<br />

HHFD63B225 7-115, 7-143<br />

HHFD63B250 7-115, 7-143<br />

HHFD63F250 7-115<br />

HHJD62B200 7-118, 7-144<br />

HHJD62B225 7-118, 7-144<br />

HHJD62B250 7-118, 7-144<br />

HHJD62B300 7-118, 7-144<br />

HHJD62B350 7-118, 7-144<br />

HHJD62B400 7-118, 7-144<br />

HHJD62F400 7-118<br />

HHJD63B200 7-118, 7-144<br />

HHJD63B225 7-118, 7-144<br />

HHJD63B250 7-118, 7-144<br />

HHJD63B300 7-118, 7-144<br />

HHJD63B350 7-118, 7-144<br />

HHJD63B400 7-118, 7-144<br />

HHJD63F400 7-118<br />

HHLD62B250 7-122, 7-144<br />

HHLD62B300 7-122, 7-144<br />

HHLD62B350 7-122, 7-144<br />

HHLD62B400 7-122, 7-144<br />

HHLD62B450 7-122, 7-144<br />

HHLD62B500 7-122, 7-144<br />

HHLD62B600 7-122, 7-144<br />

HHLD62F600 7-122<br />

HHLD62T450 7-122<br />

HHLD62T500 7-122<br />

HHLD62T600 7-122<br />

HHLD63B250 7-122, 7-144<br />

HHLD63B300 7-122, 7-144<br />

HHLD63B350 7-122, 7-144<br />

HHLD63B400 7-122, 7-144<br />

HHLD63B450 7-122, 7-144<br />

HHLD63B500 7-122, 7-144<br />

HHLD63B600 7-122, 7-144<br />

HHLD63F600 7-122<br />

HHLD63T450 7-122<br />

HHLD63T500 7-122<br />

HHLD63T600 7-122<br />

HJ65A 13-18, 5-26<br />

HJ66A 13-18, 4-20, 5-26<br />

HJC3B250 7-204<br />

HJC3B300 7-204<br />

HJC3B350 7-204<br />

HJC3B400 7-204<br />

HJD62B200 7-118, 7-144<br />

HJD62B225 7-118, 7-144<br />

HJD62B250 7-118, 7-144<br />

HJD62B300 7-118, 7-144<br />

HJD62B350 7-118, 7-144<br />

HJD62B400 7-118<br />

HJD62F400 7-118<br />

HJD62H400 7-144<br />

HJD63B200 7-118, 7-144<br />

HJD63B225 7-118, 7-144<br />

HJD63B250 7-118<br />

HJD63B300 7-118, 7-144<br />

HJD63B350 7-118, 7-144<br />

HJD63B400 7-118, 7-144<br />

HJD63F400 7-118<br />

HJD63H250 7-144<br />

HJG2B250L 7-184<br />

HJG2B300L 7-184<br />

HJG2B350L 7-184<br />

HJG2B400L 7-184<br />

HJG2F400 7-184<br />

HJG3A250L 7-185<br />

HJG3A400L 7-185<br />

HJG3B250L 7-184<br />

HJG3B300L 7-184<br />

HJG3B350L 7-184<br />

HJG3B400L 7-184<br />

HJG3F400 7-184, 7-185<br />

HJG3G250L 7-185<br />

HJG3G400L 7-185<br />

HJG3K250L 7-185<br />

HJG3K400L 7-185<br />

HJG3R250L 7-185<br />

HJG3R400L 7-185<br />

HJG3T250L 7-185<br />

HJG3T400L 7-185<br />

HJG3V250L 7-185<br />

HJG3V400L 7-185<br />

HJG3W250L 7-185<br />

HJG3W400L 7-185<br />

HJM3L400 7-203<br />

HJM3M400 7-203<br />

HJS2S400 7-202<br />

HJS3S400 7-202<br />

HJXD63S400A 7-146<br />

HL612 4-36<br />

HL63 4-36<br />

HL64 4-36<br />

HL65678 4-36<br />

HL67A 4-36<br />

HLC3B400 7-204<br />

HLC3B500 7-204<br />

HLC3B600 7-204<br />

HLC612 4-21, 5-10<br />

HLC63 4-21, 5-10<br />

HLC64 4-21, 5-10<br />

HLC65678 4-21, 5-10<br />

HLD62B250 7-122, 7-144<br />

HLD62B300 7-122, 7-144<br />

HLD62B350 7-122, 7-144<br />

HLD62B400 7-122, 7-144<br />

HLD62B450 7-122, 7-144<br />

HLD62B500 7-122, 7-144<br />

HLD62B600 7-122, 7-144<br />

HLD62F600 7-122<br />

HLD63B250 7-122, 7-144<br />

HLD63B300 7-122, 7-144<br />

HLD63B350 7-122, 7-144<br />

HLD63B400 7-122, 7-144<br />

HLD63B450 7-122, 7-144<br />

HLD63B500 7-122, 7-144<br />

HLD63B600 7-122, 7-144<br />

HLD63F600 7-122<br />

HLK2B400L 7-188<br />

HLK2B500L 7-188<br />

HLK2B600L 7-188<br />

HLK3A400L 7-189<br />

HLK3A600L 7-189<br />

HLK3B400L 7-188<br />

HLK3B500L 7-188<br />

HLK3B600L 7-188<br />

HLK3G400L 7-189<br />

I<br />

PRODUCT<br />

INDEX<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog I-15


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

I<br />

PRODUCT<br />

INDEX<br />

HLK3G600L 7-189<br />

HLK3K400L 7-189<br />

HLK3K600L 7-189<br />

HLK3R400L 7-189<br />

HLK3R600L 7-189<br />

HLK3T400L 7-189<br />

HLK3T600L 7-189<br />

HLK3V400L 7-189<br />

HLK3V600L 7-189<br />

HLK3W400L 7-189<br />

HLK3W600L 7-189<br />

HLM3J600 7-203<br />

HLM3Y600 7-203<br />

HLMD62B500 7-126, 7-145<br />

HLMD62B600 7-126, 7-145<br />

HLMD62B700 7-126, 7-145<br />

HLMD62B800 7-126, 7-145<br />

HLMD62F800 7-126<br />

HLMD63B500 7-126, 7-145<br />

HLMD63B600 7-126, 7-145<br />

HLMD63B700 7-126, 7-145<br />

HLMD63B800 7-126, 7-145<br />

HLMD63F800 7-126<br />

HLMXD63B500 7-126, 7-145<br />

HLMXD63B600 7-126, 7-145<br />

HLMXD63B700 7-126, 7-145<br />

HLMXD63B800 7-126, 7-145<br />

HLR2S600 7-202<br />

HLR3S600 7-202<br />

HLV2B400L 7-188<br />

HLV2B500L 7-188<br />

HLV2B600L 7-188<br />

HLV3B400L 7-188<br />

HLV3B500L 7-188<br />

HLV3B600L 7-188<br />

HLXD63S600A 7-146<br />

HM6123 4-36<br />

HM64 4-36<br />

HM65 4-36<br />

HM66 4-36<br />

HM678 4-36<br />

HM67A 4-36<br />

HMBK3125HR 1-22<br />

HMBK3150HR 1-22<br />

HMBK3175HR 1-22<br />

HMBK3200HR 1-22<br />

HMBK3225HR 1-22<br />

HMC3B600 7-204<br />

HMC3B700 7-204<br />

HMC3B800 7-204<br />

HMD62B500 7-129, 7-145<br />

HMD62B600 7-129<br />

HMD62B700 7-129, 7-145<br />

HMD62B800 7-129, 7-145<br />

HMD62F800 7-129<br />

HMD63B500 7-129<br />

HMD63B600 7-129, 7-145<br />

HMD63B700 7-129, 7-145<br />

HMD63B800 7-129, 7-145<br />

HMD63F800 7-129<br />

HMG2B600L 7-192<br />

HMG2B700L 7-192<br />

HMG2B800L 7-192<br />

HMG2F800 7-192<br />

HMG3A600L 7-193<br />

HMG3A800L 7-193<br />

HMG3B600L 7-192<br />

HMG3B700L 7-192<br />

HMG3B800L 7-192<br />

HMG3F800 7-192, 7-193<br />

HMG3G600L 7-193<br />

HMG3G800L 7-193<br />

HMG3K600L 7-193<br />

HMG3K800L 7-193<br />

HMG3R600L 7-193<br />

HMG3R800L 7-193<br />

HMG3T600L 7-193<br />

HMG3T800L 7-193<br />

HMG3V600L 7-193<br />

HMG3V800L 7-193<br />

HMG3W600L 7-193<br />

HMG3W800L 7-193<br />

HMM3M800 7-203<br />

HMS2S800 7-202<br />

HMS3S800 7-202<br />

HMXD63B500 7-145<br />

HMXD63B600 7-129, 7-145<br />

HMXD63B700 7-129, 7-145<br />

HMXD63B800 7-129, 7-145<br />

HN22A 4-20<br />

HN263 4-20, 4-32, 5-9<br />

HN264 4-20<br />

HN612 4-20, 5-9<br />

HN623 4-20, 5-9<br />

HN64 4-20<br />

HN656A 4-20<br />

HN656ACB 6-5, 6-7, 6-9, 6-11, 6-12,<br />

6-13, 7-68, 7-72<br />

HN678 4-20, 4-32<br />

HN678A 4-20<br />

HN678ACB 6-9, 7-68, 7-72<br />

HNB612 4-36<br />

HNB623 4-36<br />

HNB64 4-36<br />

HNB65 4-36<br />

HNB66 4-36<br />

HNB678 4-36<br />

HNB67A 4-36<br />

HNC264 4-32<br />

HNC3B100 7-204<br />

HNC3B120 7-204<br />

HNC3B800 7-204<br />

HNC3B900 7-204<br />

HNC612 4-32<br />

HNCM65A 4-22<br />

HNCM66A 4-22<br />

HND62B100 7-145<br />

HND62B120 7-145<br />

HND62B800 7-145<br />

HND62B900 7-145<br />

HND63B100 7-133, 7-145<br />

HND63B120 7-133, 7-145<br />

HND63B800 7-133, 7-145<br />

HND63B900 7-133, 7-145<br />

HND63F120 7-133<br />

HND678 4-32<br />

HNF1104NPV 4-19<br />

HNF1104NRPV 4-19<br />

HNF165NRPV 4-19<br />

HNF166NRPV 4-19<br />

HNF261 4-12<br />

HNF261J 4-12<br />

HNF261R 4-12<br />

HNF261S 4-12<br />

HNF262 4-12<br />

HNF262J 4-12<br />

HNF262R 4-12<br />

HNF262S 4-12<br />

HNF263 4-12<br />

HNF263J 4-12<br />

HNF263R 4-12<br />

HNF263S 4-12<br />

HNF361 4-12<br />

HNF361J 4-12<br />

HNF361JCH 4-17<br />

HNF361JCHW 4-17<br />

HNF361JPN 4-17<br />

HNF361JW 4-13<br />

HNF361PV 4-19<br />

HNF361PVPG 4-19<br />

HNF361R 4-12<br />

HNF361RL 4-12<br />

HNF361RPV 4-19<br />

HNF361RPVPG 4-19<br />

HNF361RW 4-13<br />

HNF361S 4-12<br />

HNF361SCH 4-17<br />

HNF361SCHW 4-17<br />

HNF361SPN 4-17<br />

HNF361SS 4-18<br />

HNF361SSW 4-18<br />

HNF361SW 4-13<br />

HNF361X 4-18, 4-29<br />

HNF362 4-12<br />

HNF362H 4-12<br />

HNF362J 4-12<br />

HNF362JCH 4-17<br />

HNF362JCHW 4-17<br />

HNF362JH 4-12<br />

HNF362JPN 4-17<br />

HNF362JW 4-13<br />

HNF362PV 4-19<br />

HNF362PVPG 4-19<br />

HNF362R 4-12<br />

HNF362RH 4-12<br />

HNF362RL 4-12<br />

HNF362RPV 4-19<br />

HNF362RPVPG 4-19<br />

HNF362RW 4-13<br />

HNF362S 4-12<br />

HNF362SCH 4-17<br />

HNF362SCHW 4-17<br />

HNF362SH 4-12<br />

HNF362SPN 4-17<br />

HNF362SS 4-18<br />

HNF362SSW 4-18<br />

HNF362SW 4-13<br />

HNF362X 4-18, 4-29<br />

HNF363 4-12<br />

HNF363J 4-12<br />

HNF363JCH 4-17<br />

HNF363JCHW 4-17<br />

HNF363JW 4-13<br />

HNF363PV 4-19<br />

HNF363PVPG 4-19<br />

HNF363R 4-12<br />

HNF363RPV 4-19<br />

HNF363RPVPG 4-19<br />

HNF363S 4-12<br />

HNF363SCH 4-17<br />

HNF363SCHW 4-17<br />

HNF363SS 4-18<br />

HNF363SSW 4-18<br />

HNF363SW 4-13<br />

HNF363X 4-18, 4-29<br />

HNF364 4-12<br />

HNF364J 4-12<br />

HNF364JW 4-13<br />

HNF364PV 4-19<br />

HNF364PVPG 4-19<br />

HNF364R 4-12<br />

HNF364RPV 4-19<br />

HNF364RPVPG 4-19<br />

HNF364S 4-12<br />

HNF364SS 4-18<br />

HNF364SSW 4-18<br />

HNF364SW 4-13<br />

HNF364X 4-18, 4-29<br />

HNF365A 4-12<br />

HNF365JA 4-12<br />

HNF365JWA 4-13<br />

HNF365RA 4-12, 4-8<br />

HNF365SA 4-12<br />

HNF365SSA 4-12<br />

HNF365SSWA 4-13<br />

HNF365SWA 4-13<br />

HNF366A 4-12<br />

HNF366JA 4-12<br />

HNF366RA 4-12, 4-8<br />

HNF366SA 4-12<br />

HNF366SSA 4-12<br />

HNF367 4-12<br />

HNF367J 4-12<br />

HNF367R 4-12<br />

HNF367S 4-12<br />

HNF368 4-12<br />

HNF368J 4-12<br />

HNF368R 4-12<br />

HNF368S 4-12<br />

HNF461 4-16, 4-30<br />

HNF461J 4-16, 4-30<br />

HNF462 4-16, 4-30<br />

HNF462J 4-16, 4-30<br />

HNF463 4-16, 4-30<br />

HNF463J 4-16, 4-30<br />

HNF464 4-16, 4-30<br />

HNF464J 4-16, 4-30<br />

HNF661J 4-16, 4-30<br />

HNF661S 4-16, 4-30<br />

HNF662J 4-16, 4-30<br />

HNF662S 4-16, 4-30<br />

HNF663J 4-16, 4-30<br />

HNF663S 4-16, 4-30<br />

HNF664J 4-16, 4-30<br />

HNF664S 4-16, 4-30<br />

HNG2B100L 7-196<br />

HNG2B120L 7-196<br />

HNG2B800L 7-196<br />

HNG2B900L 7-196<br />

HNG2F120 7-196<br />

HNG3A100L 7-197<br />

HNG3A120L 7-197<br />

HNG3A800L 7-197<br />

HNG3B100L 7-196<br />

HNG3B120L 7-196<br />

HNG3B800L 7-196<br />

HNG3B900L 7-196<br />

HNG3F120 7-196, 7-197<br />

HNG3G100L 7-197<br />

HNG3G120L 7-197<br />

HNG3G800L 7-197<br />

HNG3K100L 7-197<br />

HNG3K120L 7-197<br />

HNG3K800L 7-197<br />

HNG3R100L 7-197<br />

HNG3R120L 7-197<br />

HNG3R800L 7-197<br />

HNG3T100L 7-197<br />

HNG3T120L 7-197<br />

HNG3T800L 7-197<br />

HNG3V100L 7-197<br />

HNG3V120L 7-197<br />

HNG3V800L 7-197<br />

HNG3W100L 7-197<br />

HNG3W120L 7-197<br />

HNG3W800L 7-197<br />

HNM3M120 7-203<br />

HNS2S120 7-202<br />

HNS3S120 7-202<br />

HNXD63B100 7-133, 7-145<br />

HNXD63B120 7-133, 7-145<br />

HNXD63B900 7-133, 7-145<br />

HP61 4-20, 5-10<br />

HP62 4-20, 5-10<br />

HP63 4-20, 5-10<br />

HPC3B120 7-204<br />

HPC3B140 7-204<br />

HPC3B160 7-204<br />

HPD63B120 7-136, 7-145<br />

HPD63B140 7-136, 7-145<br />

HPD63B160 7-136, 7-145<br />

HPD63F160 7-136<br />

HPG3A120 7-200<br />

HPG3A160 7-200<br />

HPG3F160 7-200<br />

HPG3G120 7-200<br />

HPG3G160 7-200<br />

HPG3K120 7-200<br />

HPG3K160 7-200<br />

HPG3R120 7-200<br />

HPG3R160 7-200<br />

HPG3T120 7-200<br />

HPG3T160 7-200<br />

HPG3V120 7-200<br />

HPG3V160 7-200<br />

HPG3W120 7-200<br />

HPG3W160 7-200<br />

HPLF 7-214<br />

HPLG 7-160<br />

HPLL 7-215<br />

HPLM 7-215<br />

HPLP 7-215<br />

HPLQR 13-19, 7-160, 7-41<br />

HPS3S160 7-202<br />

HPX3B120 7-199<br />

HPX3B140 7-199<br />

HPX3B160 7-199<br />

HPXD63B120 7-136, 7-145<br />

HPXD63B140 7-136, 7-145<br />

HPXD63B160 7-136, 7-145<br />

HQ2100H 1-45, 3-135, 7-24<br />

HQ2125H 1-45, 3-135, 7-24<br />

HQN2150 1-45, 7-24<br />

HQN2150R 1-45, 7-24<br />

HQN2175 1-45, 7-24<br />

HQN2200 1-45, 7-24<br />

HQN2200R 1-45, 7-24<br />

HQR22B100 7-40<br />

HQR22B100H 7-40<br />

HQR22B125 7-40<br />

HQR22B125H 7-40<br />

HQR22B150 7-40<br />

HQR22B150H 7-40<br />

HQR22B175 7-40<br />

HQR22B175H 7-40<br />

HQR22B200 7-40<br />

HQR22B200H 7-40<br />

HQR22B225 7-40<br />

HQR22B225H 7-40<br />

HQR22B250 7-40<br />

HQR22B250H 7-40<br />

HQR23B100 3-135, 7-40<br />

HQR23B100H 3-135, 7-40<br />

HQR23B125 3-135, 7-40<br />

HQR23B125H 3-135, 7-40<br />

HQR23B150 3-135, 7-40<br />

HQR23B150H 3-135, 7-40<br />

HQR23B175 3-135, 7-40<br />

HQR23B175H 3-135, 7-40<br />

HQR23B200 3-135, 7-40<br />

HQR23B200H 3-135, 7-40<br />

HQR23B225 3-135, 7-40<br />

HQR23B225H 3-135, 7-40<br />

HQR23B250 7-40<br />

HQR23B250H 7-40<br />

HQR23S250HA 7-146<br />

HQS2100H 3-135, 3-136, 7-25<br />

HQS2110H 7-25<br />

HQS2125H 3-135, 3-136, 7-25<br />

HQS2150H 3-135, 3-136, 7-25<br />

HQS2175H 3-135, 3-136, 7-25<br />

HQS2200H 3-135, 3-136, 7-25<br />

HQS2225H 3-135, 3-136, 7-25<br />

HR21 4-20, 4-32, 5-9<br />

HR21A 4-20<br />

HR612 4-20, 5-9<br />

HR62 4-20, 4-32, 5-9<br />

HR63 4-20, 4-32, 5-9<br />

HR64 4-20, 4-32, 5-9<br />

HR656 5-9<br />

HR65A 13-18, 4-20, 5-26<br />

HR66A 13-18, 4-20, 5-26<br />

HRD63B160 7-139<br />

HRD63B180 7-139, 7-145<br />

HRD63B200 7-139, 7-145<br />

HRD63F200 7-139<br />

HRXD63B160 7-139<br />

HRXD63B180 7-139, 7-145<br />

HRXD63B200 7-139, 7-145<br />

HSK61 4-36, 5-10<br />

HSK61SSW 4-20, 4-36<br />

HSK623 4-36, 5-10<br />

HSK62SSW 4-20, 4-36<br />

HSK63SSW 4-20, 4-36<br />

HSK64 4-36, 5-10<br />

HSK64SSW 4-20, 4-36<br />

HT23 4-20, 4-32, 5-9<br />

HT24 4-20, 4-32, 5-9<br />

HT25A 13-18, 4-20, 5-26<br />

HT265A 13-18, 5-26<br />

HT26A 13-18, 4-20, 5-26<br />

HT63 4-20, 4-32, 5-9<br />

HT64 4-20, 4-32, 5-9<br />

HT65A 13-18, 4-20, 5-26<br />

HT66A 13-18, 4-20, 5-26<br />

I0204ML1125CU 1-48, 7-158<br />

I0303ML3100CU 1-48, 7-158<br />

ICGK 11-11, 11-23, 11-38, 11-49<br />

IGK 11-11, 11-23, 11-38, 11-49<br />

IKU12SC 9-25<br />

IKU4SC 9-25<br />

IKU6SC 9-25<br />

IKU8SC 9-25<br />

IMK1 11-11, 11-23, 11-38, 11-49<br />

IPBF 7-210<br />

IPBM 7-211<br />

IPBP 7-211<br />

J6N1 6-8, 7-118<br />

J6N12 6-13, 7-118<br />

J6N3R 6-10, 7-118<br />

JA0408B1150RT 2-72, 2-77<br />

JA0408B1150T 2-72, 2-77<br />

JA0408B1200RT 2-72, 2-77<br />

JA0408B1200T 2-72, 2-77<br />

JA0408B1400RLTM 2-73, 2-77<br />

JA0606L1200 2-72, 2-77<br />

JA0606L1200R 2-72, 2-77<br />

JA0606L1200RA 2-72, 2-77<br />

JA0816B1150CT 2-72, 2-77<br />

JA0816B1150RCT 2-72, 2-77<br />

JA0816B1150RTH 2-73, 2-77<br />

JA0816B1150TH 2-73, 2-77<br />

JA0816B1200CT 2-72, 2-77<br />

JA0816B1200RCT 2-72, 2-77<br />

JA0816B1200RT 2-72<br />

JA0816B1200RTH 2-73, 2-77<br />

JA0816B1200SCTM 2-75, 2-77<br />

JA0816B1200T 2-72<br />

JA0816B1200TH 2-73, 2-77<br />

JA0816B1350RLTM 2-73, 2-77<br />

JA0816B1400FD 2-76<br />

JA0816B1400FDS 2-76<br />

JA0816B1400RLTM 2-73, 2-77<br />

JA0816B1400SC 2-76<br />

JA0816B1400SCS 2-76<br />

JA1020B1100F 2-38, 2-73, 2-77<br />

JA1020B1100S 2-38, 2-73<br />

JA1020B1100S(Z) 2-77<br />

JA1212L1200FED 2-75, 2-77<br />

JA1212L1200SED 2-75, 2-77<br />

I-16<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

JA1224B1100FEC 2-75, 2-77<br />

JA1224B1100SEC 2-75, 2-77<br />

JA1224B1125FEC 2-75, 2-77<br />

JA1224B1125SEC 2-75, 2-77<br />

JA1632B1100FEC 2-77<br />

JA1632B1100SEC 2-77<br />

JA1632B1125FEC 2-77<br />

JA2040B1200 2-73, 2-77<br />

JA2040B1200F 2-38, 2-73, 2-77<br />

JA2040B1200FED 2-75, 2-77<br />

JA2040B1200S 2-38, 2-73<br />

JA2040B1200S(Z) 2-77<br />

JA2040B1200SED 2-75, 2-77<br />

JA2442B1200FEC 2-75, 2-77<br />

JA2442B1200SEC 2-75, 2-77<br />

JA3040B1200SECW 2-75, 2-77<br />

JA3042B1200FED 2-75, 2-77<br />

JA3042B1200SED 2-75, 2-77<br />

JA3042B1225FED 2-75, 2-77<br />

JA3042B1225SED 2-75, 2-77<br />

JA3042B1400FD 2-76<br />

JA3042B1400FDS 2-76<br />

JA3042B1400SC 2-76<br />

JA3042B1400SCS 2-76<br />

JA3042B1400SD 2-76<br />

JA3042B1400SDB 2-76<br />

JA3042B1400SDL 2-73, 2-77<br />

JA3042B1400SDS 2-76<br />

JA4040B1200SECW 2-75, 2-77<br />

JC002AR 2-71<br />

JC002CS 2-71<br />

JC002CZ 2-71<br />

JC0202B1125RJB 2-71, 2-77<br />

JC0202B1200 2-71, 2-77<br />

JC0202B1200R 2-71, 2-77<br />

JC0202B1200RJB 2-71, 2-77<br />

JC0404L1400FD 2-74<br />

JC0404L1400FDS 2-74<br />

JC0404L1400RLM 2-71, 2-77<br />

JC0404L1400SC 2-74<br />

JC0404L1400SCS 2-74<br />

JC0406L1125FEC 2-74, 2-77<br />

JC0406L1125SEC 2-74, 2-77<br />

JC0406L1200FEC 2-74, 2-77<br />

JC0406L1200H 2-71, 2-77<br />

JC0406L1200RH 2-71, 2-77<br />

JC0406L1200RHJB 2-71, 2-77<br />

JC0406L1200SEC 2-74, 2-77<br />

JD62B200 7-117, 7-144<br />

JD62B225 7-117, 7-144<br />

JD62B250 7-117, 7-144<br />

JD62B300 7-117, 7-144<br />

JD62B350 7-117, 7-144<br />

JD62B400 7-117, 7-144<br />

JD62F400 7-117<br />

JD62T200 7-117, 7-118<br />

JD62T225 7-117, 7-118<br />

JD62T250 7-117, 7-118, 7-121, 7-122<br />

JD62T300 7-117, 7-118, 7-121, 7-122<br />

JD62T350 7-117, 7-118, 7-121, 7-122<br />

JD62T400 7-117, 7-118, 7-121, 7-122<br />

JD63B200 7-117, 7-142, 7-144<br />

JD63B225 7-117, 7-142, 7-144<br />

JD63B250 7-117, 7-142, 7-144<br />

JD63B300 7-117, 7-142, 7-144<br />

JD63B350 7-117, 7-142, 7-144<br />

JD63B400 7-117, 7-142, 7-144<br />

JD63F400 7-117<br />

JD63T200 7-117, 7-118<br />

JD63T225 7-117, 7-118<br />

JD63T250 7-117, 7-118, 7-121, 7-122<br />

JD63T300 7-117, 7-118, 7-121, 7-122<br />

JD63T350 7-117, 7-118, 7-121, 7-122<br />

JD63T400 7-117, 7-118, 7-121, 7-122<br />

JD6HBL 7-160<br />

JD6HPL 7-160<br />

JDTERMSHIELD 7-160<br />

JPD-116046 4-17<br />

JPD-83046 4-17<br />

JXD22B200 7-117, 7-144<br />

JXD22B225 7-117, 7-144<br />

JXD22B250 7-117, 7-144<br />

JXD22B300 7-117, 7-144<br />

JXD22B350 7-117, 7-144<br />

JXD22B400 7-117, 7-144<br />

JXD22S400A 7-146<br />

JXD23B200 7-117, 7-144<br />

JXD23B225 7-117, 7-144<br />

JXD23B250 7-117, 7-144<br />

JXD23B300 7-117, 7-142, 7-144<br />

JXD23B350 7-117, 7-142, 7-144<br />

JXD23B400 7-117, 7-142, 7-144<br />

JXD23S400A 7-146<br />

JXD62B200 7-117, 7-144<br />

JXD62B225 7-117, 7-144<br />

JXD62B250 7-117, 7-144<br />

JXD62B300 7-117, 7-144<br />

JXD62B350 7-117, 7-144<br />

JXD62B400 7-117, 7-144<br />

JXD62H400 7-140<br />

JXD63B200 7-117, 7-144<br />

JXD63B225 7-117, 7-144<br />

JXD63B250 7-117, 7-144<br />

JXD63B300 7-117<br />

JXD63B350 7-117<br />

JXD63B400 7-117<br />

JXD63H400 7-140, 7-141, 7-144<br />

JXD63L400 7-140, 7-141, 7-144<br />

JXD63S400A 7-146<br />

K11D255001 8-17<br />

K11D255002 8-17<br />

K11D255201 8-17<br />

K11D255202 8-17<br />

LBRA1 4-35, 5-6<br />

LBRA2 4-35, 5-6<br />

LC Series Lighting Control 17-87,<br />

17-88, 17-89, 17-90, 17-91<br />

LD1E060 6-3, 7-111, 7-154<br />

LD1E100 7-111, 7-154<br />

LD62B250 7-121, 7-144<br />

LD62B300 7-121, 7-144<br />

LD62B350 7-121, 7-144<br />

LD62B400 7-121, 7-144<br />

LD62B450 7-121, 7-144<br />

LD62B500 7-121, 7-144<br />

LD62B600 7-121, 7-144<br />

LD62F600 7-121<br />

LD62T450 7-121, 7-122<br />

LD62T500 7-121, 7-122<br />

LD62T600 7-121, 7-122<br />

LD63B250 7-121, 7-144<br />

LD63B300 7-121, 7-144<br />

LD63B350 7-121, 7-144<br />

LD63B400 7-121, 7-144<br />

LD63B450 7-121, 7-144<br />

LD63B500 7-121, 7-142, 7-144<br />

LD63B600 7-121, 7-142, 7-144<br />

LD63F600 7-121<br />

LD63T450 7-121, 7-122<br />

LD63T500 7-121, 7-122<br />

LD63T600 7-121, 7-122<br />

LD6N1 6-8, 7-122<br />

LD6N12 6-13, 7-122<br />

LD6N3R 6-10, 7-122<br />

LD6SS4 6-12, 7-118, 7-122<br />

LDK2B050L 7-176<br />

LDK2B060L 7-176<br />

LDK2B070L 7-176<br />

LDK2B080L 7-176<br />

LDK2B090L 7-176<br />

LDK2B100L 7-176<br />

LDK2B110L 7-176<br />

LDK2B125L 7-176<br />

LDK2B150L 7-176<br />

LDK3A060L 7-177<br />

LDK3A100L 7-177<br />

LDK3A150L 7-177<br />

LDK3B050L 7-176<br />

LDK3B060L 7-176<br />

LDK3B070L 7-176<br />

LDK3B080L 7-176<br />

LDK3B090L 7-176<br />

LDK3B100L 7-176<br />

LDK3B110L 7-176<br />

LDK3B125L 7-176<br />

LDK3B150L 7-176<br />

LDK3G060L 7-177<br />

LDK3G100L 7-177<br />

LDK3G150L 7-177<br />

LDK3K060L 7-177<br />

LDK3K100L 7-177<br />

LDK3K150L 7-177<br />

LDK3R060L 7-177<br />

LDK3R100L 7-177<br />

LDK3R150L 7-177<br />

LDK3T060L 7-177<br />

LDK3T100L 7-177<br />

LDK3T150L 7-177<br />

LDK3V060L 7-177<br />

LDK3V100L 7-177<br />

LDK3V150L 7-177<br />

LDK3W060L 7-177<br />

LDK3W100L 7-177<br />

LDK3W150L 7-177<br />

LDP302 15-80<br />

LDP304 15-80<br />

LDP306 15-80<br />

LDP308 15-80<br />

LDP310 15-80<br />

LDP313 15-80<br />

LDP316 15-80<br />

LDP4024 15-80<br />

LDP4044 15-80<br />

LDP4064 15-80<br />

LDP4084 15-80<br />

LDP4104 15-80<br />

LE Series Lighting Control 17-81,<br />

17-82, 17-83, 17-84, 17-85, 17-86<br />

LF111N 4-6<br />

LF111NR 4-6<br />

LF211N 4-6<br />

LF211NR 4-6<br />

LFK2B100L 7-180<br />

LFK2B110L 7-180<br />

LFK2B125L 7-180<br />

LFK2B150L 7-180<br />

LFK2B175L 7-180<br />

LFK2B200L 7-180<br />

LFK2B225L 7-180<br />

LFK2B250L 7-180<br />

LFK3A100L 7-181<br />

LFK3A150L 7-181<br />

LFK3A250L 7-181<br />

LFK3B100L 7-180<br />

LFK3B110L 7-180<br />

LFK3B125L 7-180<br />

LFK3B150L 7-180<br />

LFK3B175L 7-180<br />

LFK3B200L 7-180<br />

LFK3B225L 7-180<br />

LFK3B250L 7-180<br />

LFK3G100L 7-181<br />

LFK3G150L 7-181<br />

LFK3G250L 7-181<br />

LFK3K100L 7-181<br />

LFK3K150L 7-181<br />

LFK3K250L 7-181<br />

LFK3R100L 7-181<br />

LFK3R150L 7-181<br />

LFK3R250L 7-181<br />

LFK3T100L 7-181<br />

LFK3T150L 7-181<br />

LFK3T250L 7-181<br />

LFK3V100L 7-181<br />

LFK3V150L 7-181<br />

LFK3V250L 7-181<br />

LFK3W100L 7-181<br />

LFK3W150L 7-181<br />

LFK3W250L 7-181<br />

LFR3S250 7-202<br />

LG123636CTS2 2-24<br />

LG124848CTS2 2-24<br />

LGB1B015B 7-33<br />

LGB1B020B 7-33<br />

LGB1B025B 7-33<br />

LGB1B030B 7-33<br />

LGB1B035B 7-33<br />

LGB1B040B 7-33<br />

LGB1B045B 7-33<br />

LGB1B050B 7-33<br />

LGB1B060B 7-33<br />

LGB1B070B 7-33<br />

LGB1B080B 7-33<br />

LGB1B090B 7-33<br />

LGB1B100B 7-33<br />

LGB1B110B 7-33<br />

LGB1B125B 7-33<br />

LGB1K015B 7-34<br />

LGB1K020B 7-34<br />

LGB1K025B 7-34<br />

LGB1K030B 7-34<br />

LGB1K035B 7-34<br />

LGB1K040B 7-34<br />

LGB1K045B 7-34<br />

LGB1K050B 7-34<br />

LGB1K060B 7-34<br />

LGB1K070B 7-34<br />

LGB1K080B 7-34<br />

LGB1K090B 7-34<br />

LGB1K100B 7-34<br />

LGB1K110B 7-34<br />

LGB1K125B 7-34<br />

LGB2B015B 7-33<br />

LGB2B020B 7-33<br />

LGB2B025B 7-33<br />

LGB2B030B 7-33<br />

LGB2B035B 7-33<br />

LGB2B040B 7-33<br />

LGB2B045B 7-33<br />

LGB2B050B 7-33<br />

LGB2B060B 7-33<br />

LGB2B070B 7-33<br />

LGB2B080B 7-33<br />

LGB2B090B 7-33<br />

LGB2B100B 7-33<br />

LGB2B110B 7-33<br />

LGB2B125B 7-33<br />

LGB2K015B 7-34<br />

LGB2K020B 7-34<br />

LGB2K025B 7-34<br />

LGB2K030B 7-34<br />

LGB2K035B 7-34<br />

LGB2K040B 7-34<br />

LGB2K045B 7-34<br />

LGB2K050B 7-34<br />

LGB2K060B 7-34<br />

LGB2K070B 7-34<br />

LGB2K080B 7-34<br />

LGB2K090B 7-34<br />

LGB2K100B 7-34<br />

LGB2K110B 7-34<br />

LGB2K125B 7-34<br />

LGB3B015B 7-33<br />

LGB3B020B 7-33<br />

LGB3B025B 7-33<br />

LGB3B030B 7-33<br />

LGB3B035B 7-33<br />

LGB3B040B 7-33<br />

LGB3B045B 7-33<br />

LGB3B050B 7-33<br />

LGB3B060B 7-33<br />

LGB3B070B 7-33<br />

LGB3B080B 7-33<br />

LGB3B090B 7-33<br />

LGB3B100B 7-33<br />

LGB3B110B 7-33<br />

LGB3B125B 7-33<br />

LGB3K015B 7-34<br />

LGB3K020B 7-34<br />

LGB3K025B 7-34<br />

LGB3K030B 7-34<br />

LGB3K035B 7-34<br />

LGB3K040B 7-34<br />

LGB3K045B 7-34<br />

LGB3K050B 7-34<br />

LGB3K060B 7-34<br />

LGB3K070B 7-34<br />

LGB3K080B 7-34<br />

LGB3K090B 7-34<br />

LGB3K100B 7-34<br />

LGB3K110B 7-34<br />

LGB3K125B 7-34<br />

LGG1B015L 7-43<br />

LGG1B020L 7-43<br />

LGG1B025L 7-43<br />

LGG1B030L 7-43<br />

LGG1B035L 7-43<br />

LGG1B040L 7-43<br />

LGG1B045L 7-43<br />

LGG1B050L 7-43<br />

LGG1B060L 7-43<br />

LGG1B070L 7-43<br />

LGG1B080L 7-43<br />

LGG1B090L 7-43<br />

LGG1B100L 7-43<br />

LGG1B110L 7-43<br />

LGG1B125L 7-43<br />

LGG2B015L 7-43<br />

LGG2B020L 7-43<br />

LGG2B025L 7-43<br />

LGG2B030L 7-43<br />

LGG2B035L 7-43<br />

LGG2B040L 7-43<br />

LGG2B045L 7-43<br />

LGG2B050L 7-43<br />

LGG2B060L 7-43<br />

LGG2B070L 7-43<br />

LGG2B080L 7-43<br />

LGG2B090L 7-43<br />

LGG2B100L 7-43<br />

LGG2B110L 7-43<br />

LGG2B125L 7-43<br />

LGG3B015L 7-43<br />

LGG3B020L 7-43<br />

LGG3B025L 7-43<br />

LGG3B030L 7-43<br />

LGG3B035L 7-43<br />

LGG3B040L 7-43<br />

LGG3B045L 7-43<br />

LGG3B050L 7-43<br />

LGG3B060L 7-43<br />

LGG3B070L 7-43<br />

LGG3B080L 7-43<br />

LGG3B090L 7-43<br />

LGG3B100L 7-43<br />

LGG3B110L 7-43<br />

LGG3B125L 7-43<br />

LGMM0202B1125RJBX 2-12<br />

LGMM0202B1150RJBX 2-12<br />

LGMM0202B1200RJBX 2-12<br />

LJG2B250L 7-184<br />

LJG2B300L 7-184<br />

LJG2B350L 7-184<br />

LJG2B400L 7-184<br />

LJG2F400 7-184<br />

LJG3A250L 7-185<br />

LJG3A400L 7-185<br />

LJG3B250L 7-184<br />

LJG3B300L 7-184<br />

LJG3B350L 7-184<br />

LJG3B400L 7-184<br />

LJG3F400 7-184, 7-185<br />

LJG3G250L 7-185<br />

LJG3G400L 7-185<br />

LJG3K250L 7-185<br />

LJG3K400L 7-185<br />

LJG3R250L 7-185<br />

LJG3R400L 7-185<br />

LJG3T250L 7-185<br />

LJG3T400L 7-185<br />

LJG3V250L 7-185<br />

LJG3V400L 7-185<br />

LJG3W250L 7-185<br />

LJG3W400L 7-185<br />

LJS3S400 7-202<br />

LK11600N2 3-127, 3-128, 3-129<br />

LK11750 3-127<br />

LK11750N2 3-127, 3-128, 3-129<br />

LK12350N2 3-127, 3-129<br />

LK12500 3-127<br />

LK12500N2 3-127, 3-128, 3-129<br />

LK12500N2E 3-127, 3-128, 3-129<br />

LK12600N2 3-127, 3-128, 3-129<br />

LK12750N2 3-127, 3-128, 3-129<br />

LK13500 3-127<br />

LK13500N2 3-127, 3-128, 3-129<br />

LK13750 3-127<br />

LK13750N2 3-127, 3-128, 3-129<br />

LK13750N2E 3-127, 3-128, 3-129<br />

LK14500 3-127, 3-128<br />

LK14500N2 3-127, 3-128, 3-129<br />

LK14500N2E 3-127, 3-128, 3-129<br />

LK15600N2 3-127, 3-128, 3-129<br />

LK15750N2 3-127, 3-128, 3-129<br />

LK16750N2 3-127, 3-128, 3-129<br />

LK18500N2C 3-128, 3-129<br />

LK18500N2CD 3-127, 3-129<br />

LK18570N2A 3-129<br />

LK18570N2AD 3-129<br />

LK18750N2A 3-128<br />

LK18750N2AD 3-127<br />

LK31600N2 3-127, 3-128, 3-129<br />

LK31750 3-127<br />

LK31750N2 3-127, 3-128, 3-129<br />

LK32350N2 3-127, 3-128, 3-129<br />

LK32500 3-127<br />

LK32500N2 3-127, 3-128, 3-129<br />

LK32500N2E 3-127, 3-128, 3-129<br />

LK32600N2 3-127, 3-128, 3-129<br />

LK32750N2 3-127, 3-128, 3-129<br />

LK33500 3-127<br />

LK33500N2 3-127, 3-128, 3-129<br />

LK33750 3-127<br />

LK33750N2 3-127, 3-128, 3-129<br />

LK33750N2E 3-127, 3-128, 3-129<br />

LK34500 3-127, 3-128<br />

LK34500N2 3-127, 3-128, 3-129<br />

LK34500N2E 3-127, 3-128, 3-129<br />

LK35600N2 3-127, 3-128, 3-129<br />

LK35750N2 3-127, 3-128, 3-129<br />

I<br />

PRODUCT<br />

INDEX<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog I-17


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

I<br />

PRODUCT<br />

INDEX<br />

LK36750N2 3-127, 3-128, 3-129<br />

LK38500N2C 3-127, 3-128, 3-129<br />

LK38500N2CD 3-127, 3-129<br />

LK38570N2A 3-129<br />

LK38570N2AD 3-129<br />

LK38750N2A 3-127, 3-128<br />

LK38750N2AD 3-127<br />

LKB4 13-19<br />

LKB6 13-19<br />

LKB8 13-19<br />

LKF4 13-18<br />

LKF6 13-18<br />

LLK2B400L 7-188<br />

LLK2B500L 7-188<br />

LLK2B600L 7-188<br />

LLK3A400L 7-189<br />

LLK3A600L 7-189<br />

LLK3B400L 7-188<br />

LLK3B500L 7-188<br />

LLK3B600L 7-188<br />

LLK3G400L 7-189<br />

LLK3G600L 7-189<br />

LLK3K400L 7-189<br />

LLK3K600L 7-189<br />

LLK3R400L 7-189<br />

LLK3R600L 7-189<br />

LLK3T400L 7-189<br />

LLK3T600L 7-189<br />

LLK3V400L 7-189<br />

LLK3V600L 7-189<br />

LLK3W400L 7-189<br />

LLK3W600L 7-189<br />

LLP1200 3-130<br />

LLP600 3-130<br />

LLR3S600 7-202<br />

LMAP1600 7-199, 7-211<br />

LMD1 6-8, 7-126<br />

LMD12 6-13, 7-126<br />

LMD3R 6-10, 7-126<br />

LMD62B500 7-125, 7-144<br />

LMD62B600 7-125, 7-144<br />

LMD62B700 7-125, 7-144<br />

LMD62B800 7-125, 7-144<br />

LMD62F800 7-125<br />

LMD62T500 7-125, 7-126<br />

LMD62T600 7-125, 7-126<br />

LMD62T700 7-125, 7-126<br />

LMD62T800 7-125, 7-126<br />

LMD63B500 7-125, 7-142, 7-144<br />

LMD63B600 7-125, 7-142, 7-144<br />

LMD63B700 7-125, 7-142, 7-144<br />

LMD63B800 7-125, 7-142, 7-144<br />

LMD63F800 7-125<br />

LMD63T500 7-125, 7-126<br />

LMD63T600 7-125, 7-126<br />

LMD63T700 7-125, 7-126<br />

LMD63T800 7-125, 7-126<br />

LMG2B600L 7-192<br />

LMG2B700L 7-192<br />

LMG2B800L 7-192<br />

LMG2F800 7-192<br />

LMG3A600L 7-193<br />

LMG3A800L 7-193<br />

LMG3B600L 7-192<br />

LMG3B700L 7-192<br />

LMG3B800L 7-192<br />

LMG3F800 7-192, 7-193<br />

LMG3G600L 7-193<br />

LMG3G800L 7-193<br />

LMG3K600L 7-193<br />

LMG3K800L 7-193<br />

LMG3R600L 7-193<br />

LMG3R800L 7-193<br />

LMG3T600L 7-193<br />

LMG3T800L 7-193<br />

LMG3V600L 7-193<br />

LMG3V800L 7-193<br />

LMG3W600L 7-193<br />

LMG3W800L 7-193<br />

LMS3S800 7-202<br />

LMXD62B600 7-125, 7-144<br />

LMXD62B700 7-125, 7-144<br />

LMXD62B800 7-125, 7-144<br />

LMXD63A800 7-140, 7-141, 7-144<br />

LMXD63B500 7-125, 7-144<br />

LMXD63B600 7-125, 7-144<br />

LMXD63B700 7-125, 7-144<br />

LMXD63B800 7-125, 7-144<br />

LMXD63L800 7-140, 7-141, 7-144<br />

LMXD63S800A 7-146<br />

LN1E100 6-3, 7-111, 7-154<br />

LNF222RA 4-6<br />

LNF222RL 4-6<br />

LNG2B100L 7-196<br />

LNG2B120L 7-196<br />

LNG2B800L 7-196<br />

LNG2B900L 7-196<br />

LNG2F120 7-196<br />

LNG3A100L 7-197<br />

LNG3A120L 7-197<br />

LNG3A800L 7-197<br />

LNG3B100L 7-196<br />

LNG3B120L 7-196<br />

LNG3B800L 7-196<br />

LNG3B900L 7-196<br />

LNG3F120 7-196, 7-197<br />

LNG3G100L 7-197<br />

LNG3G120L 7-197<br />

LNG3G800L 7-197<br />

LNG3K100L 7-197<br />

LNG3K120L 7-197<br />

LNG3K800L 7-197<br />

LNG3R100L 7-197<br />

LNG3R120L 7-197<br />

LNG3R800L 7-197<br />

LNG3T100L 7-197<br />

LNG3T120L 7-197<br />

LNG3T800L 7-197<br />

LNG3V100L 7-197<br />

LNG3V120L 7-197<br />

LNG3V800L 7-197<br />

LNG3W100L 7-197<br />

LNG3W120L 7-197<br />

LNG3W800L 7-197<br />

LNLK30A 11-11, 11-22<br />

LNLK42A 11-11, 11-22<br />

LNLK54A 11-11, 11-22<br />

LNS3S120 7-202<br />

LPDC01 11-11, 11-23, 11-38, 11-49<br />

LPDC02 11-11, 11-23, 11-38, 11-49<br />

LPG3A120 7-200<br />

LPG3A160 7-200<br />

LPG3F160 7-200<br />

LPG3G120 7-200<br />

LPG3G160 7-200<br />

LPG3K120 7-200<br />

LPG3K160 7-200<br />

LPG3R120 7-200<br />

LPG3R160 7-200<br />

LPG3T120 7-200<br />

LPG3T160 7-200<br />

LPG3V120 7-200<br />

LPG3V160 7-200<br />

LPG3W120 7-200<br />

LPG3W160 7-200<br />

LPS3S160 7-202<br />

LPX3B120 7-199<br />

LPX3B140 7-199<br />

LPX3B160 7-199<br />

LSCT1236 13-22<br />

LSCT432 13-22<br />

LSCT436 13-22<br />

LSCT632 13-22<br />

LSCT636 13-22<br />

LSCT836 13-22<br />

LX100FP 2-82<br />

LXD62B450 7-121, 7-144<br />

LXD62B500 7-121, 7-144<br />

LXD62B600 7-121, 7-144<br />

LXD62L600 7-140<br />

LXD63B450 7-121, 7-144<br />

LXD63B500 7-121, 7-144<br />

LXD63B600 7-121, 7-144<br />

LXD63H600 7-140, 7-141, 7-144<br />

LXD63L600 7-140, 7-141, 7-144<br />

LXD63S600A 7-146<br />

LXX-14 11-101<br />

LXX-20 11-101<br />

LXX-26 11-101<br />

LXX-32 11-101<br />

LXX-38 11-101<br />

LXX-41 11-101<br />

LXX-44 11-101<br />

LXX-53 11-101<br />

LXX-56 11-101<br />

LXX-62 11-101<br />

LXX-65 11-101<br />

LXX-68 11-101<br />

LXX-74 11-101<br />

LXX-80 11-101<br />

LXX-86 11-101<br />

LXX50-F 11-101<br />

LXXP-T 11-101<br />

MB120 1-48, 7-158<br />

MB9301 7-136, 7-137, 7-139<br />

MBK100 1-45, 7-24<br />

MBK100A 1-22, 1-45, 7-24<br />

MBK125 1-45, 7-24<br />

MBK125A 1-22, 1-45, 7-24<br />

MBK150 1-45, 7-24<br />

MBK150A 1-22, 1-45, 7-24<br />

MBK175 1-45, 7-24<br />

MBK200 1-45, 7-24<br />

MBK200A 1-22, 1-45, 7-24<br />

MBK225 1-45, 7-24<br />

MBK225A 1-22, 1-45, 7-24<br />

MBK3100 1-22<br />

MBK3125HHR 1-22<br />

MBK3125HR 1-22<br />

MBK3125R 1-22<br />

MBK3150HHR 1-22<br />

MBK3150HR 1-22<br />

MBK3150R 1-22<br />

MBK3175HHR 1-22<br />

MBK3175HR 1-22<br />

MBK3175R 1-22<br />

MBK3200HHR 1-22<br />

MBK3200HR 1-22<br />

MBK3200R 1-22<br />

MBK3225HHR 1-22<br />

MBK3225HR 1-22<br />

MBK3225R 1-22<br />

MBKBC1NBA 11-11, 11-22<br />

MBKBC3 11-11, 11-22<br />

MBKBC3NBA 11-11, 11-22<br />

MBKBL1 11-11, 11-22<br />

MBKBL1A 11-11, 11-22<br />

MBKBL3 11-11, 11-22<br />

MBKBL3A 11-11, 11-22<br />

MBKED1 11-11, 11-22<br />

MBKED1A 11-11, 11-22<br />

MBKED3 11-11, 11-22<br />

MBKED3100 11-12<br />

MBKED3100A 11-12<br />

MBKED3125 11-12<br />

MBKED3125A 11-12<br />

MBKED3A 11-11, 11-22<br />

MBKFD1 11-11, 11-22<br />

MBKFD1A 11-11, 11-22<br />

MBKFD3 11-11, 11-22<br />

MBKFD3150 11-12<br />

MBKFD3150A 11-12<br />

MBKFD3175 11-12<br />

MBKFD3175A 11-12<br />

MBKFD3200 11-12<br />

MBKFD3200A 11-12<br />

MBKFD3225 11-12<br />

MBKFD3225A 11-12<br />

MBKFD3250 11-12<br />

MBKFD3250A 11-12<br />

MBKFD3A 11-11, 11-22<br />

MBKJD1 11-11, 11-22<br />

MBKJD12300 11-12<br />

MBKJD12300A 11-12<br />

MBKJD12400 11-12<br />

MBKJD12400A 11-12<br />

MBKJD1300 11-12<br />

MBKJD1300A 11-12<br />

MBKJD1400 11-12<br />

MBKJD1400A 11-12<br />

MBKJD1A 11-11, 11-22<br />

MBKJD3 11-11, 11-22<br />

MBKJD32300 11-12<br />

MBKJD32300A 11-12<br />

MBKJD32400 11-12<br />

MBKJD32400A 11-12<br />

MBKJD3300 11-12<br />

MBKJD3300A 11-12<br />

MBKJD3400 11-12<br />

MBKJD3400A 11-12<br />

MBKJD3A 11-11, 11-22<br />

MBKNB1 11-11, 11-22<br />

MBKNB3 11-11, 11-22<br />

MBKQJ1 11-11, 11-22<br />

MBKQJ1A 11-11, 11-22<br />

MBKQJ3 11-11, 11-22<br />

MBKQJ3A 11-11, 11-22<br />

MBKQR1 11-11, 11-12, 11-22<br />

MBKQR1125A 11-12<br />

MBKQR1125HA 11-12<br />

MBKQR1150A 11-12<br />

MBKQR1150HA 11-12<br />

MBKQR1175A 11-12<br />

MBKQR1175HA 11-12<br />

MBKQR1200A 11-12<br />

MBKQR1200HA 11-12<br />

MBKQR1225A 11-12<br />

MBKQR1225HA 11-12<br />

MBKQR1A 11-11, 11-22<br />

MBKQR3 11-11, 11-12, 11-22<br />

MBKQR3125A 11-12<br />

MBKQR3125HA 11-12<br />

MBKQR3150A 11-12<br />

MBKQR3150HA 11-12<br />

MBKQR3175A 11-12<br />

MBKQR3175HA 11-12<br />

MBKQR3200A 11-12<br />

MBKQR3200HA 11-12<br />

MBKQR3225A 11-12<br />

MBKQR3225HA 11-12<br />

MBKQR3A 11-11, 11-22<br />

MBKQRC1FK 11-101<br />

MBKQRFK 11-11, 11-15, 11-23<br />

MBPG1600 7-199, 7-211<br />

MBPG1601 7-199, 7-211<br />

MBR9302 7-136, 7-137, 7-139<br />

MC0408B1150RGA 2-39<br />

MC0408B1150RT 2-38<br />

MC0408B1150T 2-38<br />

MC0408B1200JLT 2-40<br />

MC0408B1200RGA 2-39<br />

MC0408B1200RT 2-38<br />

MC0408B1200T 2-38<br />

MC0408B1400RLTM 2-41<br />

MC0606L1200R 2-38<br />

MC0606L1200RA 2-38<br />

MC0606L1200RAD 2-39<br />

MC0606L1200RGA 2-39<br />

MC0606L1200RJB 2-38<br />

MC0606L1200RN 2-38<br />

MC0816B1150CT 2-38<br />

MC0816B1150RCT 2-38<br />

MC0816B1150RGA 2-39<br />

MC0816B1150RTH 2-41<br />

MC0816B1150T 2-38<br />

MC0816B1150TH 2-41<br />

MC0816B1200CT 2-38<br />

MC0816B1200EFN 2-46, 2-75<br />

MC0816B1200ESN 2-46, 2-75<br />

MC0816B1200EST 2-46<br />

MC0816B1200FCTM 2-46<br />

MC0816B1150JLT 2-40<br />

MC0816B1200RCT 2-38<br />

MC0816B1200RGA 2-39<br />

MC0816B1200RT 2-38<br />

MC0816B1200RTB 2-38<br />

MC0816B1200RTD 2-39<br />

MC0816B1200RTH 2-41<br />

MC0816B1200RTZ 2-38<br />

MC0816B1200SCT 2-46<br />

MC0816B1200SCTM 2-46<br />

MC0816B1200T 2-38<br />

MC0816B1200TH 2-41<br />

MC0816B1350RLTM 2-41<br />

MC0816B1400FD 2-47<br />

MC0816B1400FDS 2-47<br />

MC0816B1400RLTM 2-41<br />

MC0816B1400SC 2-47<br />

MC0816B1400SCS 2-47<br />

MC0816B1400SDL 2-41<br />

MC0816S1200SCT 2-44<br />

MC1020B1100EY 2-50<br />

MC1020B1100F 2-38, 2-73<br />

MC1020B1100FZ 2-38, 2-73<br />

MC1020B1100S 2-38, 2-73<br />

MC1020B1100SZ 2-38, 2-73<br />

MC1212L1200FED 2-48<br />

MC1212L1200SED 2-48<br />

MC1224B1100CEY 2-50<br />

MC1224B1100EFC 2-46, 2-75<br />

MC1224B1100ESC 2-46, 2-75<br />

MC1224B1100FEC 2-46<br />

MC1224B1100SEC 2-46<br />

MC1224B1125 2-41<br />

MC1224B1125EFC 2-46, 2-75<br />

MC1224B1125ESC 2-46, 2-75<br />

MC1224B1125FEC 2-46<br />

MC1224B1125JLC 2-40<br />

MC1224B1125R 2-41<br />

MC1224B1125SEC 2-46<br />

MC1224B1200JLC 2-40<br />

MC1830F3100CEY 2-50<br />

MC2040B1150 2-41<br />

MC2040B1150JLC 2-40<br />

MC2040B1150R 2-41<br />

MC2040B1150RC 2-38<br />

MC2040B1150RJBC 2-38<br />

MC2040B1200 2-41<br />

MC2040B1200EFC 2-46, 2-75<br />

MC2040B1200ESC 2-46, 2-75<br />

MC2040B1200F 2-38, 2-73<br />

MC2040B1200FED 2-48<br />

MC2040B1200FZ 2-38, 2-73<br />

MC2040B1200JLC 2-40<br />

MC2040B1200R 2-41<br />

MC2040B1200RC 2-38<br />

MC2040B1200RJBC 2-38<br />

MC2040B1200S 2-38, 2-73<br />

MC2040B1200SED 2-48<br />

MC2040B1200SZ 2-38, 2-73<br />

MC2040S1200JLC 2-44<br />

MC2040S1200SZ 2-44<br />

MC2440B1200CEY 2-50<br />

MC2442B1200EFC 2-75<br />

MC2442B1200EFV 2-46<br />

MC2442B1200ESC 2-75<br />

MC2442B1200ESV 2-46<br />

MC2442B1200FEC 2-46<br />

MC2442B1200SEC 2-46<br />

MC2442B1225EFC 2-46, 2-75<br />

MC2442B1225ESC 2-46, 2-75<br />

MC2442B1225FEC 2-46<br />

MC2442B1225SEC 2-46<br />

MC2442B1250FE2 2-48<br />

MC2442B1400SD 2-47<br />

MC2442B1400SDB 2-41<br />

MC2442B1400SDL 2-41<br />

MC2442B1400SDS 2-47<br />

MC2442F3200CEY 2-50<br />

MC2442S1200FC 2-44<br />

MC2442S1200SC 2-44<br />

MC3040B1200R 2-41<br />

MC3040B1200SECW 2-46<br />

MC3040S1200SC 2-44<br />

MC3042B1200FED 2-48<br />

MC3042B1200JLC 2-40<br />

MC3042B1200RC 2-38<br />

MC3042B1200RJB 2-38<br />

MC3042B1200SED 2-48<br />

MC3042B1225FED 2-48<br />

MC3042B1225SED 2-48<br />

MC3042B1250FE2 2-48<br />

MC3042B1400FD 2-47<br />

MC3042B1400FDS 2-47<br />

MC3042B1400SC 2-47<br />

MC3042B1400SCS 2-47<br />

MC3042B1400SD 2-47<br />

MC3042B1400SDB 2-41<br />

MC3042B1400SDL 2-41<br />

MC3042B1400SDS 2-47<br />

MC3042S1400FC 2-45<br />

MC3042S1400FCL 2-45<br />

MC3042S1400FCS 2-45<br />

MC3042S1400FD 2-45<br />

MC3042S1400FDS 2-45<br />

MC3042S1400SC 2-45<br />

MC3042S1400SCL 2-45<br />

MC3042S1400SCS 2-45<br />

MC3042S1400SD 2-45<br />

MC3042S1400SDS 2-45<br />

MC4040B1200R 2-41<br />

MC4040B1200SC 2-47<br />

MC4040B1200SD 2-47<br />

MC4040B1200SECW 2-46<br />

MC4040S1200SC 2-44<br />

MCHK 11-11, 11-23<br />

MCS603L 5-12, 5-13<br />

MCS603R 5-12, 5-13<br />

MCS606L 5-12, 5-13<br />

MCS606R 5-12, 5-13<br />

MCS610 5-13<br />

MCS610L 5-12, 5-13<br />

MCS610R 5-12, 5-13<br />

MCS620 5-13<br />

MCS620L 5-12, 5-13<br />

MCS620R 5-12, 5-13<br />

MCSAK116 5-13<br />

MCSAK126 5-13<br />

MCSAK216 5-13<br />

MCSAK226 5-13<br />

I-18<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

MCSAKL136 5-13<br />

MCSAKL236 5-13<br />

MCSAKR136 5-13<br />

MCSAKR236 5-13<br />

MD62B500 7-128, 7-145<br />

MD62B600 7-128, 7-145<br />

MD62B700 7-128, 7-145<br />

MD62B800 7-128, 7-145<br />

MD62F800 7-128<br />

MD62T500 7-128, 7-129<br />

MD62T600 7-128, 7-129<br />

MD62T700 7-128, 7-129<br />

MD62T800 7-128, 7-129, 7-132<br />

MD63B500 7-128, 7-145<br />

MD63B600 7-128, 7-145<br />

MD63B700 7-128, 7-145<br />

MD63B800 7-128, 7-145<br />

MD63F800 7-128<br />

MD63T500 7-128, 7-129<br />

MD63T600 7-128, 7-129<br />

MD63T700 7-128, 7-129<br />

MD63T800 7-128, 7-129, 7-132, 7-133<br />

MDTERMSHIELD 7-160<br />

MFCF036 7-163, 7-208<br />

MFCF048 7-208<br />

MFCF060 7-208<br />

MFCF072 7-208<br />

MFCF084 7-208<br />

MFCF096 7-208<br />

MFCF120 7-208<br />

MFCF144 7-208<br />

MFCM036 7-208, 7-209<br />

MFCM048 7-208, 7-209<br />

MFCM060 7-208, 7-209<br />

MFCM072 7-208, 7-209<br />

MFCM084 7-208, 7-209<br />

MFCM096 7-208, 7-209<br />

MFCM120 7-208, 7-209<br />

MFCM144 7-208, 7-209<br />

MFCP048 7-209<br />

MFCP060 7-209<br />

MFCP072 7-209<br />

MFCP096 7-209<br />

MFCP120 7-209<br />

MFCP144 7-209<br />

MFHG3R 7-163<br />

MFHG4X 7-163<br />

MFHM3R 7-208, 7-209<br />

MFHM3RB 7-208, 7-209<br />

MFHM3RS 7-208, 7-209<br />

MFHM3RSB 7-208, 7-209<br />

MFHM4X 7-208, 7-209<br />

MFHP3RS 7-209<br />

MFHP3RSB 7-209<br />

MFHP4X 7-209<br />

MFKF3R 7-208<br />

MFKG3R3 7-163<br />

MFKG4X3 7-163<br />

MFKL3R 7-208<br />

MFKM3R 7-209<br />

MFKP3RS 7-209<br />

MFMF 7-208<br />

MFMG 7-163<br />

MFML 7-208<br />

MFMM 7-209<br />

MFMP 7-209<br />

MFSFA1 7-208<br />

MFSFA2 7-208<br />

MFSLA1 7-208<br />

MFSLA2 7-208<br />

MFSPA1 7-209<br />

MFSPA2 7-209<br />

MG1 11-77<br />

MG1D 11-91, 13-25<br />

MI5404 7-161<br />

MI5405 7-161<br />

MI5406 7-161<br />

MI5413 7-161<br />

MI5444 7-161<br />

ML11225RJ 3-60<br />

ML11400RJFS 3-64<br />

ML12225RJ 3-60<br />

ML12400RJFS 3-64<br />

ML13100RJ 3-61<br />

ML13225RJ 3-61<br />

ML13400RJFS 3-64<br />

ML21125RJ 3-59<br />

ML21225RJ 3-60<br />

ML22125RJ 3-59<br />

ML22AB225RJ 3-60<br />

ML22BC225RJ 3-60<br />

ML22CA225RJ 3-60<br />

ML23100RJ 3-61<br />

ML23225RJ 3-61<br />

ML31125RJ 3-59<br />

ML31225RJ 3-60<br />

ML32125RJ 3-59<br />

ML32225RJ 3-60<br />

ML33100RJ 3-61<br />

ML33225RJ 3-61<br />

ML41125RJ 3-59<br />

ML41225RJ 3-60<br />

ML42125RJ 3-59<br />

ML42AB225RJ 3-60<br />

ML42BC225RJ 3-60<br />

ML42CA225RJ 3-60<br />

ML43100RJ 3-61<br />

ML43225RJ 3-61<br />

ML51125RJ 3-59<br />

ML52125RJ 3-59<br />

ML61125RJ 3-59<br />

ML62125RJ 3-59<br />

MLKA1 11-11, 11-15, 11-22<br />

MLKA1A 11-11, 11-22<br />

MLKA3 11-11, 11-15, 11-22<br />

MLKA3A 11-11, 11-22<br />

MLKC1 11-11, 11-22<br />

MLKC1A 11-11, 11-22<br />

MLKC3 11-11, 11-22<br />

MLKC3A 11-11, 11-22<br />

MLZ32125RJ 3-69<br />

MLZ42125RJ 3-69<br />

MLZ52125RJ 3-69<br />

MLZ62125RJ 3-69<br />

MLZF32125RJ 3-69<br />

MLZF42125RJ 3-69<br />

MLZF52125RJ 3-69<br />

MLZF62125RJ 3-69<br />

MM0202B1100ESC 2-42, 2-74<br />

MM0202B1100RLC 2-37<br />

MM0202B1125RJB 2-36<br />

MM0202B1125RJBX 2-36<br />

MM0202B1150 2-36<br />

MM0202B1150R 2-36<br />

MM0202B1150RJB 2-36<br />

MM0202B1150RJBX 2-36<br />

MM0202B1200 2-36<br />

MM0202B1200ESC 2-42, 2-74<br />

MM0202B1200JLX 2-37<br />

MM0202B1200R 2-36<br />

MM0202B1200RJB 2-36<br />

MM0202B1200RJBX 2-36<br />

MM0202B1200RLC 2-37<br />

MM0202B1400SC 2-42<br />

MM0202B1400SCL 2-42<br />

MM0202B1400SCS 2-42<br />

MM0202B1400SD 2-42<br />

MM0202B1400SDL 2-42<br />

MM0202B1400SDS 2-42<br />

MM0202F1100CEY 2-49<br />

MM0202F1100EY 2-49<br />

MM0202F1200CEY 2-49<br />

MM0202F1200EY 2-49<br />

MM0202L1100EY 2-49<br />

MM0202L1125EFC 2-42, 2-74<br />

MM0202L1125ESC 2-42, 2-74<br />

MM0202L1125RLC 2-37<br />

MM0202L1200CEY 2-49<br />

MM0202L1200EFC 2-42, 2-74<br />

MM0202L1200ESC 2-42, 2-74<br />

MM0202L1200EY 2-49<br />

MM0202L1200JLX 2-37<br />

MM0202L1200RLC 2-37<br />

MM0202ML1100S 2-36<br />

MM0202ML1125H 2-36<br />

MM0202S1200H 2-44<br />

MM0202S1200RHJ 2-44<br />

MM0202S1200RJB 2-44<br />

MM0303B3100RLC 2-37<br />

MM0303B3200RLC 2-37<br />

MM0303F3100CEY 2-49<br />

MM0303F3100EY 2-49<br />

MM0303F3200CEY 2-49<br />

MM0303F3200EY 2-49<br />

MM0303L3100EY 2-49<br />

MM0303L3100RLC 2-37<br />

MM0303L3200CEY 2-49<br />

MM0303L3200EY 2-49<br />

MM0404B11515RL 2-37<br />

MM0404B12010RL 2-37<br />

MM0404B1400RLM 2-37<br />

MM0404L1400FD 2-42<br />

MM0404L1400FDS 2-42<br />

MM0404L1400RLM 2-37<br />

MM0404L1400SC 2-42<br />

MM0404L1400SCS 2-42<br />

MM0404L1400SDL 2-37<br />

MM0406L1125FEC 2-42<br />

MM0406L1125SEC 2-42<br />

MM0406L1200FEC 2-42<br />

MM0406L1200GA 2-36<br />

MM0406L1200H 2-36<br />

MM0406L1200RGA 2-36<br />

MM0406L1200RH 2-36<br />

MM0406L1200RHJB 2-36<br />

MM0406L1200SEC 2-42<br />

MM21125 3-53<br />

MM21125J 3-54<br />

MM21125R 3-53<br />

MM21125RB 3-53<br />

MM21125RJ 3-54<br />

MM21125RJB 3-54<br />

MM21225 3-53<br />

MM21225J 3-54<br />

MM21225R 3-53<br />

MM21225RB 3-53<br />

MM21225RJ 3-54<br />

MM21225RJB 3-54<br />

MM22125J 3-55<br />

MM22125RJ 3-55<br />

MM22125RJB 3-55<br />

MM22225J 3-55<br />

MM22225RJ 3-55<br />

MM22225RJB 3-55<br />

MM31125 3-53<br />

MM31125J 3-54<br />

MM31125R 3-53<br />

MM31125RB 3-53<br />

MM31125RJ 3-54<br />

MM31125RJB 3-54<br />

MM31225 3-53<br />

MM31225J 3-54<br />

MM31225R 3-53<br />

MM31225RB 3-53<br />

MM31225RJ 3-54<br />

MM31225RJB 3-54<br />

MM32125J 3-55<br />

MM32125RJ 3-55<br />

MM32125RJB 3-55<br />

MM32225J 3-55<br />

MM32225RJ 3-55<br />

MM32225RJB 3-55<br />

MM41125 3-53<br />

MM41125J 3-54<br />

MM41125R 3-53<br />

MM41125RB 3-53<br />

MM41125RJ 3-54<br />

MM41125RJB 3-54<br />

MM41225 3-53<br />

MM41225J 3-54<br />

MM41225R 3-53<br />

MM41225RB 3-53<br />

MM41225RJ 3-54<br />

MM41225RJB 3-54<br />

MM42125J 3-55<br />

MM42125RJ 3-55<br />

MM42125RJB 3-55<br />

MM42225J 3-55<br />

MM42225RJ 3-55<br />

MM42225RJB 3-55<br />

MM51125 3-53<br />

MM51125J 3-54<br />

MM51125R 3-53<br />

MM51125RB 3-53<br />

MM51125RJ 3-54<br />

MM51125RJB 3-54<br />

MM51225 3-53<br />

MM51225J 3-54<br />

MM51225R 3-53<br />

MM51225RB 3-53<br />

MM51225RJ 3-54<br />

MM51225RJB 3-54<br />

MM52125J 3-55<br />

MM52125RJ 3-55<br />

MM52125RJB 3-55<br />

MM52225J 3-55<br />

MM52225RJ 3-55<br />

MM52225RJB 3-55<br />

MM61125 3-53<br />

MM61125J 3-54<br />

MM61125R 3-53<br />

MM61125RB 3-53<br />

MM61125RJ 3-54<br />

MM61125RJB 3-54<br />

MM61225 3-53<br />

MM61225J 3-54<br />

MM61225R 3-53<br />

MM61225RB 3-53<br />

MM61225RJ 3-54<br />

MM61225RJB 3-54<br />

MM62125J 3-55<br />

MM62125RJ 3-55<br />

MM62125RJB 3-55<br />

MM62225J 3-55<br />

MM62225RJ 3-55<br />

MM62225RJB 3-55<br />

MMBMT1 3-138<br />

MMBMT2 3-138<br />

MMCLIP 3-132<br />

MMCVR1 3-138<br />

MMCVR1R 3-138<br />

MMCVR2 3-138<br />

MMCVR2R 3-138<br />

MMCVRLOW 3-138<br />

MMCVRSCR 3-138<br />

MMPK11 3-138<br />

MMPK13 3-138<br />

MMPK21 3-138<br />

MMPK23 3-138<br />

MMRAIL 3-132<br />

MMS Series Manual Control<br />

Switches 17-8, 17-9<br />

MMSCK1 3-138<br />

MMSCK2 3-138<br />

MMSRPK 3-138<br />

MMZR24 3-132<br />

MMZR36 3-132<br />

MMZR48 3-132<br />

MMZR60 3-132<br />

MN22125J 3-93<br />

MN22225J 3-93<br />

MN32125J 3-93<br />

MN32225J 3-93<br />

MN42125J 3-93<br />

MN42225J 3-93<br />

MN52125J 3-93<br />

MN52225J 3-93<br />

MN62125J 3-93<br />

MN62225J 3-93<br />

MN6BL 7-160<br />

MN6PLD 7-160<br />

MND61 6-8, 7-128, 7-132<br />

MND612 6-13, 7-128, 7-132<br />

MND63 6-10, 7-128, 7-132<br />

MOE6120 7-164<br />

MOE6240 7-164<br />

MOF6024DC 7-164<br />

MOF6048DC 7-164<br />

MOF6120 7-164<br />

MOF6120/L 7-164<br />

MOF6125DC 7-164<br />

MOF6240 7-164<br />

MOF6240/L 7-164<br />

MOJ6024DC 7-164<br />

MOJ6048DC 7-164<br />

MOJ6120 7-164<br />

MOJ6120/L 7-164<br />

MOJ6125DC 7-164<br />

MOJ6240 7-164<br />

MOJ6240/L 7-164<br />

MOLMD6024DC 7-164<br />

MOLMD6048DC 7-164<br />

MOLMD6120 7-164<br />

MOLMD6120/L 7-164<br />

MOLMD6125DC 7-164<br />

MOLMD6240 7-164<br />

MP0406B1200R 2-11<br />

MP0406B1200RJL 2-11<br />

MP0606L1200 2-11<br />

MP0606L1200R 2-11<br />

MP0606L1200RJL 2-11<br />

MRS Series Manual Control<br />

Switches 17-8, 17-9<br />

MS14TB 2-11<br />

MS15TB 2-11<br />

MS17TB 2-11<br />

MS24TB 2-11<br />

MS25TB 2-11<br />

MS27TB 2-11<br />

MS44UTB 2-11<br />

MSE6 7-161<br />

MSE6100 7-161<br />

MSF6 7-161<br />

MSF650 7-161<br />

MSJ6 7-161<br />

MSK2001 13-26<br />

MSK2003 13-26<br />

MSKE1 7-161<br />

MSKE2 7-161<br />

MSKF2 7-214<br />

MSKF4 7-214<br />

MSKG4 7-161<br />

MSKL4 7-215<br />

MSKM4 7-215<br />

MSKP4 7-215<br />

MSLMD 7-161<br />

MSMN 7-161<br />

MSPR6 7-161<br />

MSQR3 7-161, 7-41<br />

MT Series Control Power<br />

Transformers 17-98<br />

MT11225 3-74<br />

MT12225J 3-74<br />

MT13225J 3-74<br />

MT21225 3-74<br />

MT22AB225J 3-74<br />

MT22BC225J 3-74<br />

MT22CA225J 3-74<br />

MT23225J 3-74<br />

MT31225 3-74<br />

MT32225J 3-74<br />

MT33225J 3-74<br />

MTG Series Control Power<br />

Transformers 17-99, 17-100<br />

MTRPB 7-211<br />

MTRPM 7-211<br />

MTRPN 7-211<br />

MTRPR 7-211<br />

MTRPY 7-211<br />

MXD62B500 7-145<br />

MXD62B600 7-128, 7-145<br />

MXD62B700 7-128, 7-145<br />

MXD62B800 7-128, 7-145<br />

MXD63A800 7-140, 7-141, 7-145<br />

MXD63B500 7-145<br />

MXD63B600 7-128, 7-145<br />

MXD63B700 7-128, 7-145<br />

MXD63B800 7-128, 7-145<br />

MXD63H800 7-140, 7-141, 7-145<br />

MXD63L800 7-140, 7-141, 7-145<br />

MXD63S800A 7-146<br />

N02SJD 7-119<br />

N03SJD 7-119, 7-123<br />

N04SJD 7-119, 7-123<br />

N05SLD 7-123<br />

N06SLD 7-123<br />

N06SMDA 7-130<br />

N07SMDA 7-130<br />

N08SMDA 7-130, 7-134<br />

N10SNDA 7-134<br />

N125GG 6-11, 6-3, 6-9<br />

N125GG4X 6-12<br />

N125X 6-9<br />

N12SNDA 7-134<br />

N14SPD 7-137<br />

N16SPD 7-137<br />

N2000 6-6, 6-7, 6-9<br />

N2250 6-9<br />

N2250X 6-9, 7-49, 7-54,<br />

7-56, 7-57, 7-62<br />

N250X 6-11, 6-12, 6-13, 6-4,<br />

6-7, 6-9, 7-114<br />

N250X 6-11, 6-12, 6-3, 6-4, 6-7, 6-9,<br />

7-49, 7-54, 7-56, 7-57, 7-62<br />

NBK03 11-11, 11-23<br />

NBK04 11-11, 11-23<br />

NBK05 11-11, 11-23<br />

NBK06 11-11, 11-23<br />

NBK3 11-38, 11-49<br />

NBK4 11-38, 11-49<br />

NBK5 11-38, 11-49<br />

NBK6 11-38, 11-49<br />

NBK7 11-38, 11-49<br />

NBK8 11-38, 11-49<br />

ND62B100 7-145<br />

ND62B120 7-132, 7-145<br />

ND62B800 7-132, 7-145<br />

ND62B900 7-132, 7-145<br />

I<br />

PRODUCT<br />

INDEX<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog I-19


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

I<br />

PRODUCT<br />

INDEX<br />

ND62F120 7-132<br />

ND62T100 7-132<br />

ND62T120 7-132<br />

ND62T900 7-132<br />

ND63B100 7-132, 7-145<br />

ND63B120 7-132, 7-145<br />

ND63B800 7-132, 7-145<br />

ND63B900 7-132, 7-145<br />

ND63F120 7-132<br />

ND63T100 7-132, 7-133<br />

ND63T120 7-132, 7-133<br />

ND63T900 7-132, 7-133<br />

NDK2B050L 7-176<br />

NDK2B060L 7-176<br />

NDK2B070L 7-176<br />

NDK2B080L 7-176<br />

NDK2B090L 7-176<br />

NDK2B100L 7-176<br />

NDK2B110L 7-176<br />

NDK2B125L 7-176<br />

NDK2B150L 7-176<br />

NDK3A060L 7-177<br />

NDK3A100L 7-177<br />

NDK3A150L 7-177<br />

NDK3B050L 7-176<br />

NDK3B060L 7-176<br />

NDK3B070L 7-176<br />

NDK3B080L 7-176<br />

NDK3B090L 7-176<br />

NDK3B100L 7-176<br />

NDK3B110L 7-176<br />

NDK3B125L 7-176<br />

NDK3B150L 7-176<br />

NDK3G060L 7-177<br />

NDK3G100L 7-177<br />

NDK3G150L 7-177<br />

NDK3K060L 7-177<br />

NDK3K100L 7-177<br />

NDK3K150L 7-177<br />

NDK3R060L 7-177<br />

NDK3R100L 7-177<br />

NDK3R150L 7-177<br />

NDK3T060L 7-177<br />

NDK3T100L 7-177<br />

NDK3T150L 7-177<br />

NDK3V060L 7-177<br />

NDK3V100L 7-177<br />

NDK3V150L 7-177<br />

NDK3W060L 7-177<br />

NDK3W100L 7-177<br />

NDK3W150L 7-177<br />

NF355HDTK 4-31, 4-33<br />

NF355SSDTK 4-31, 4-33<br />

NF454DTK 4-31, 4-33<br />

NF454SSDTK 4-31, 4-33<br />

NF455DTK 4-31, 4-33<br />

NF456DTK 4-31, 4-33<br />

NF457DTK 4-31, 4-33<br />

NFK2B100L 7-180<br />

NFK2B110L 7-180<br />

NFK2B125L 7-180<br />

NFK2B150L 7-180<br />

NFK2B175L 7-180<br />

NFK2B200L 7-180<br />

NFK2B225L 7-180<br />

NFK2B250L 7-180<br />

NFK3A100L 7-181<br />

NFK3A150L 7-181<br />

NFK3A250L 7-181<br />

NFK3B100L 7-180<br />

NFK3B110L 7-180<br />

NFK3B125L 7-180<br />

NFK3B150L 7-180<br />

NFK3B175L 7-180<br />

NFK3B200L 7-180<br />

NFK3B225L 7-180<br />

NFK3B250L 7-180<br />

NFK3G100L 7-181<br />

NFK3G150L 7-181<br />

NFK3G250L 7-181<br />

NFK3K100L 7-181<br />

NFK3K150L 7-181<br />

NFK3K250L 7-181<br />

NFK3R100L 7-181<br />

NFK3R150L 7-181<br />

NFK3R250L 7-181<br />

NFK3T100L 7-181<br />

NFK3T150L 7-181<br />

NFK3T250L 7-181<br />

NFK3V100L 7-181<br />

NFK3V150L 7-181<br />

NFK3V250L 7-181<br />

NFK3W100L 7-181<br />

NFK3W150L 7-181<br />

NFK3W250L 7-181<br />

NFR451DTK 4-31, 4-33<br />

NFR452DTK 4-31, 4-33<br />

NFR453DTK 4-31, 4-33<br />

NFR454DTK 4-31, 4-33<br />

NFR455DTK 4-31, 4-33<br />

NFR456DTK 4-31, 4-33<br />

NFR457DTK 4-31, 4-33<br />

NG1D 11-91, 13-25<br />

NGB1B015B 7-33<br />

NGB1B020B 7-33<br />

NGB1B025B 7-33<br />

NGB1B030B 7-33<br />

NGB1B035B 7-33<br />

NGB1B040B 7-33<br />

NGB1B045B 7-33<br />

NGB1B050B 7-33<br />

NGB1B060B 7-33<br />

NGB1B070B 7-33<br />

NGB1B080B 7-33<br />

NGB1B090B 7-33<br />

NGB1B100B 7-33<br />

NGB1B110B 7-33<br />

NGB1B125B 7-33<br />

NGB1K015B 7-34<br />

NGB1K020B 7-34<br />

NGB1K025B 7-34<br />

NGB1K030B 7-34<br />

NGB1K035B 7-34<br />

NGB1K040B 7-34<br />

NGB1K045B 7-34<br />

NGB1K050B 7-34<br />

NGB1K060B 7-34<br />

NGB1K070B 7-34<br />

NGB1K080B 7-34<br />

NGB1K090B 7-34<br />

NGB1K100B 7-34<br />

NGB1K110B 7-34<br />

NGB1K125B 7-34<br />

NGB2B015B 7-33<br />

NGB2B020B 7-33<br />

NGB2B025B 7-33<br />

NGB2B030B 7-33<br />

NGB2B035B 7-33<br />

NGB2B040B 7-33<br />

NGB2B045B 7-33<br />

NGB2B050B 7-33<br />

NGB2B060B 7-33<br />

NGB2B070B 7-33<br />

NGB2B080B 7-33<br />

NGB2B090B 7-33<br />

NGB2B100B 7-33<br />

NGB2B110B 7-33<br />

NGB2B125B 7-33<br />

NGB2K015B 7-34<br />

NGB2K020B 7-34<br />

NGB2K025B 7-34<br />

NGB2K030B 7-34<br />

NGB2K035B 7-34<br />

NGB2K040B 7-34<br />

NGB2K045B 7-34<br />

NGB2K050B 7-34<br />

NGB2K060B 7-34<br />

NGB2K070B 7-34<br />

NGB2K080B 7-34<br />

NGB2K090B 7-34<br />

NGB2K100B 7-34<br />

NGB2K110B 7-34<br />

NGB2K125B 7-34<br />

NGB3B015B 7-33<br />

NGB3B020B 7-33<br />

NGB3B025B 7-33<br />

NGB3B030B 7-33<br />

NGB3B035B 7-33<br />

NGB3B040B 7-33<br />

NGB3B045B 7-33<br />

NGB3B050B 7-33<br />

NGB3B060B 7-33<br />

NGB3B070B 7-33<br />

NGB3B080B 7-33<br />

NGB3B090B 7-33<br />

NGB3B100B 7-33<br />

NGB3B110B 7-33<br />

NGB3B125B 7-33<br />

NGB3K015B 7-34<br />

NGB3K020B 7-34<br />

NGB3K025B 7-34<br />

NGB3K030B 7-34<br />

NGB3K035B 7-34<br />

NGB3K040B 7-34<br />

NGB3K045B 7-34<br />

NGB3K050B 7-34<br />

NGB3K060B 7-34<br />

NGB3K070B 7-34<br />

NGB3K080B 7-34<br />

NGB3K090B 7-34<br />

NGB3K100B 7-34<br />

NGB3K110B 7-34<br />

NGB3K125B 7-34<br />

NGG1B015L 7-43<br />

NGG1B020L 7-43<br />

NGG1B025L 7-43<br />

NGG1B030L 7-43<br />

NGG1B035L 7-43<br />

NGG1B040L 7-43<br />

NGG1B045L 7-43<br />

NGG1B050L 7-43<br />

NGG1B060L 7-43<br />

NGG1B070L 7-43<br />

NGG1B080L 7-43<br />

NGG1B090L 7-43<br />

NGG1B100L 7-43<br />

NGG1B110L 7-43<br />

NGG1B125L 7-43<br />

NGG2B015L 7-43<br />

NGG2B020L 7-43<br />

NGG2B025L 7-43<br />

NGG2B030L 7-43<br />

NGG2B035L 7-43<br />

NGG2B040L 7-43<br />

NGG2B045L 7-43<br />

NGG2B050L 7-43<br />

NGG2B060L 7-43<br />

NGG2B070L 7-43<br />

NGG2B080L 7-43<br />

NGG2B090L 7-43<br />

NGG2B100L 7-43<br />

NGG2B110L 7-43<br />

NGG2B125L 7-43<br />

NGG3B015L 7-43<br />

NGG3B020L 7-43<br />

NGG3B025L 7-43<br />

NGG3B030L 7-43<br />

NGG3B035L 7-43<br />

NGG3B040L 7-43<br />

NGG3B045L 7-43<br />

NGG3B050L 7-43<br />

NGG3B060L 7-43<br />

NGG3B070L 7-43<br />

NGG3B080L 7-43<br />

NGG3B090L 7-43<br />

NGG3B100L 7-43<br />

NGG3B110L 7-43<br />

NGG3B125L 7-43<br />

NGSD060 7-216<br />

NGSF100 7-216<br />

NGSF150 7-216<br />

NGSJ250 7-216, 7-217<br />

NGSL400 7-217<br />

NGSM600 7-217<br />

NGSN800 7-217<br />

NGSP120 7-217<br />

NGSP160 7-217<br />

NJG2B250L 7-184<br />

NJG2B300L 7-184<br />

NJG2B350L 7-184<br />

NJG2B400L 7-184<br />

NJG2F400 7-184<br />

NJG3A250L 7-185<br />

NJG3A400L 7-185<br />

NJG3B250L 7-184<br />

NJG3B300L 7-184<br />

NJG3B350L 7-184<br />

NJG3B400L 7-184<br />

NJG3F400 7-184, 7-185<br />

NJG3G250L 7-185<br />

NJG3G400L 7-185<br />

NJG3K250L 7-185<br />

NJG3K400L 7-185<br />

NJG3R250L 7-185<br />

NJG3R400L 7-185<br />

NJG3T250L 7-185<br />

NJG3T400L 7-185<br />

NJG3V250L 7-185<br />

NJG3V400L 7-185<br />

NJG3W250L 7-185<br />

NJG3W400L 7-185<br />

NJJ2B250L 7-184<br />

NJJ2B300L 7-184<br />

NJJ2B350L 7-184<br />

NJJ2B400L 7-184<br />

NJJ3B250L 7-184<br />

NJJ3B300L 7-184<br />

NJJ3B350L 7-184<br />

NJJ3B400L 7-184<br />

NLK2B400L 7-188<br />

NLK2B500L 7-188<br />

NLK2B600L 7-188<br />

NLK3A400L 7-189<br />

NLK3A600L 7-189<br />

NLK3B400L 7-188<br />

NLK3B500L 7-188<br />

NLK3B600L 7-188<br />

NLK3G400L 7-189<br />

NLK3G600L 7-189<br />

NLK3K400L 7-189<br />

NLK3K600L 7-189<br />

NLK3R400L 7-189<br />

NLK3R600L 7-189<br />

NLK3T400L 7-189<br />

NLK3T600L 7-189<br />

NLK3V400L 7-189<br />

NLK3V600L 7-189<br />

NLK3W400L 7-189<br />

NLK3W600L 7-189<br />

NMG2B600L 7-192<br />

NMG2B700L 7-192<br />

NMG2B800L 7-192<br />

NMG2F800 7-192<br />

NMG3A600L 7-193<br />

NMG3A800L 7-193<br />

NMG3B600L 7-192<br />

NMG3B700L 7-192<br />

NMG3B800L 7-192<br />

NMG3F800 7-192, 7-193<br />

NMG3G600L 7-193<br />

NMG3G800L 7-193<br />

NMG3K600L 7-193<br />

NMG3K800L 7-193<br />

NMG3R600L 7-193<br />

NMG3R800L 7-193<br />

NMG3T600L 7-193<br />

NMG3T800L 7-193<br />

NMG3V600L 7-193<br />

NMG3V800L 7-193<br />

NMG3W600L 7-193<br />

NMG3W800L 7-193<br />

NNG2B100L 7-196<br />

NNG2B120L 7-196<br />

NNG2B800L 7-196<br />

NNG2B900L 7-196<br />

NNG2F120 7-196<br />

NNG3A100L 7-197<br />

NNG3A120L 7-197<br />

NNG3A800L 7-197<br />

NNG3B100L 7-196<br />

NNG3B120L 7-196<br />

NNG3B800L 7-196<br />

NNG3B900L 7-196<br />

NNG3F120 7-196, 7-197<br />

NNG3G100L 7-197<br />

NNG3G120L 7-197<br />

NNG3G800L 7-197<br />

NNG3K100L 7-197<br />

NNG3K120L 7-197<br />

NNG3K800L 7-197<br />

NNG3R100L 7-197<br />

NNG3R120L 7-197<br />

NNG3R800L 7-197<br />

NNG3T100L 7-197<br />

NNG3T120L 7-197<br />

NNG3T800L 7-197<br />

NNG3V100L 7-197<br />

NNG3V120L 7-197<br />

NNG3V800L 7-197<br />

NNG3W100L 7-197<br />

NNG3W120L 7-197<br />

NNG3W800L 7-197<br />

NPG3A120 7-200<br />

NPG3A160 7-200<br />

NPG3F160 7-200<br />

NPG3G120 7-200<br />

NPG3G160 7-200<br />

NPG3K120 7-200<br />

NPG3K160 7-200<br />

NPG3R120 7-200<br />

NPG3R160 7-200<br />

NPG3T120 7-200<br />

NPG3T160 7-200<br />

NPG3V120 7-200<br />

NPG3V160 7-200<br />

NPG3W120 7-200<br />

NPG3W160 7-200<br />

NPX3B120 7-199<br />

NPX3B140 7-199<br />

NPX3B160 7-199<br />

NR26 11-38<br />

NR32 11-38<br />

NR38 11-38<br />

NR44 11-38<br />

NR50 11-38<br />

NR56 11-38<br />

NR62 11-38<br />

NR68 11-38<br />

NR74 11-38<br />

NXD62B100 7-132, 7-145<br />

NXD62B120 7-132, 7-145<br />

NXD62B900 7-132, 7-145<br />

NXD63B100 7-132, 7-145<br />

NXD63B120 7-132, 7-145<br />

NXD63B900 7-132, 7-145<br />

NXD63S120A 7-146<br />

OFCK620 5-12<br />

OFCK661 5-12<br />

P1224B3100CU 1-13<br />

P1224L3125CU 1-13<br />

P1718MC250A 11-10<br />

P1718MC250AT 11-10<br />

P1718MC250C 11-10<br />

P1718MC250CT 11-10<br />

P1718MC400A 11-10<br />

P1718MC400C 11-10<br />

P1730MC250A 11-10<br />

P1730MC250AT 11-10<br />

P1730MC250C 11-10<br />

P1730MC250CT 11-10<br />

P1730MC400A 11-10<br />

P1730MC400AT 11-10<br />

P1730MC400C 11-10<br />

P1730MC400CT 11-10<br />

P1742MC250A 11-10<br />

P1742MC250AT 11-10<br />

P1742MC250C 11-10<br />

P1742MC250CT 11-10<br />

P1742MC400A 11-10<br />

P1742MC400AT 11-10<br />

P1742MC400C 11-10<br />

P1742MC400CT 11-10<br />

P1754MC250AT 11-10<br />

P1754MC250CT 11-10<br />

P1754MC400AT 11-10<br />

P1754MC400CT 11-10<br />

P1A18BL100ATS 11-19<br />

P1A18BL100ATST 11-19<br />

P1A18FX250ATS 11-19<br />

P1A18FX250ATST 11-19<br />

P1A18JX400ATS 11-19<br />

P1A18MC250A 11-10<br />

P1A18MC250AT 11-10<br />

P1A18MC250C 11-10<br />

P1A18MC250CT 11-10<br />

P1A18MC400A 11-10<br />

P1A18MC400C 11-10<br />

P1A18ML125ATS 11-19<br />

P1A18ML125ATST 11-19<br />

P1A18ML250ATS 11-19<br />

P1A18ML250ATST 11-19<br />

P1A18ML400ATS 11-19<br />

P1A18QR225ATS 11-19<br />

P1A18QR225ATST 11-19<br />

P1A30BL100ATS 11-19<br />

P1A30BL100ATST 11-19<br />

P1A30FX250ATS 11-19<br />

P1A30FX250ATST 11-19<br />

P1A30JX400ATS 11-19<br />

P1A30JX400ATST 11-19<br />

P1A30MC250A 11-10<br />

P1A30MC250AT 11-10<br />

P1A30MC250C 11-10<br />

P1A30MC250CT 11-10<br />

P1A30MC400A 11-10<br />

P1A30MC400AT 11-10<br />

P1A30MC400C 11-10<br />

P1A30MC400CT 11-10<br />

P1A30ML125ATS 11-19<br />

P1A30ML125ATST 11-19<br />

I-20<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

P1A30ML250ATS 11-19<br />

P1A30ML250ATST 11-19<br />

P1A30ML400ATS 11-19<br />

P1A30ML400ATST 11-19<br />

P1A30QR225ATS 11-19<br />

P1A30QR225ATST 11-19<br />

P1A42BL100ATS 11-19<br />

P1A42BL100ATST 11-19<br />

P1A42FX250ATS 11-19<br />

P1A42FX250ATST 11-19<br />

P1A42JX400ATS 11-19<br />

P1A42JX400ATST 11-19<br />

P1A42MC250A 11-10<br />

P1A42MC250AT 11-10<br />

P1A42MC250C 11-10<br />

P1A42MC250CT 11-10<br />

P1A42MC400A 11-10<br />

P1A42MC400AT 11-10<br />

P1A42MC400C 11-10<br />

P1A42MC400CT 11-10<br />

P1A42ML125ATS 11-19<br />

P1A42ML125ATST 11-19<br />

P1A42ML250ATS 11-19<br />

P1A42ML250ATST 11-19<br />

P1A42ML400ATS 11-19<br />

P1A42ML400ATST 11-19<br />

P1A42QR225ATS 11-19<br />

P1A42QR225ATST 11-19<br />

P1A54BL100ATST 11-19<br />

P1A54FX250ATST 11-19<br />

P1A54JX400ATST 11-19<br />

P1A54MC250AT 11-10<br />

P1A54MC250CT 11-10<br />

P1A54MC400AT 11-10<br />

P1A54MC400CT 11-10<br />

P1A54ML125ATST 11-19<br />

P1A54ML250ATST 11-19<br />

P1A54ML400ATST 11-19<br />

P1A54QR225ATST 11-19<br />

P1A66BL100ATST 11-19<br />

P1A66FX250ATST 11-19<br />

P1A66JX400ATSN 11-19<br />

P1A66ML125ATST 11-19<br />

P1A66ML250ATST 11-19<br />

P1A66ML400ATSN 11-19<br />

P1A66QR225ATST 11-19<br />

P1C18BL100ATS 11-19<br />

P1C18BL100ATST 11-19<br />

P1C18FX250ATS 11-19<br />

P1C18FX250ATST 11-19<br />

P1C18JX400ATS 11-19<br />

P1C18ML125ATS 11-19<br />

P1C18ML125ATST 11-19<br />

P1C18ML250ATS 11-19<br />

P1C18ML250ATST 11-19<br />

P1C18ML400ATS 11-19<br />

P1C18NB125ATS 11-19<br />

P1C18NB125ATST 11-19<br />

P1C18QR225ATS 11-19<br />

P1C18QR225ATST 11-19<br />

P1C30BL100ATS 11-19<br />

P1C30BL100ATST 11-19<br />

P1C30FX250ATS 11-19<br />

P1C30FX250ATST 11-19<br />

P1C30JX400ATS 11-19<br />

P1C30JX400ATST 11-19<br />

P1C30ML125ATS 11-19<br />

P1C30ML125ATST 11-19<br />

P1C30ML250ATS 11-19<br />

P1C30ML250ATST 11-19<br />

P1C30ML400ATS 11-19<br />

P1C30ML400ATST 11-19<br />

P1C30NB125ATS 11-19<br />

P1C30NB125ATST 11-19<br />

P1C30QR225ATS 11-19<br />

P1C30QR225ATST 11-19<br />

P1C42BL100ATS 11-19<br />

P1C42BL100ATST 11-19<br />

P1C42FX250ATS 11-19<br />

P1C42FX250ATST 11-19<br />

P1C42JX400ATS 11-19<br />

P1C42JX400ATST 11-19<br />

P1C42ML125ATS 11-19<br />

P1C42ML125ATST 11-19<br />

P1C42ML250ATS 11-19<br />

P1C42ML250ATST 11-19<br />

P1C42ML400ATS 11-19<br />

P1C42ML400ATST 11-19<br />

P1C42NB125ATS 11-19<br />

P1C42NB125ATST 11-19<br />

P1C42QR225ATS 11-19<br />

P1C42QR225ATST 11-19<br />

P1C54BL100ATST 11-19<br />

P1C54FX250ATST 11-19<br />

P1C54JX400ATST 11-19<br />

P1C54ML125ATST 11-19<br />

P1C54ML250ATST 11-19<br />

P1C54ML400ATST 11-19<br />

P1C54NB125ATST 11-19<br />

P1C54QR225ATST 11-19<br />

P1C66BL100ATST 11-19<br />

P1C66FX250ATST 11-19<br />

P1C66JX400ATSN 11-19<br />

P1C66ML125ATST 11-19<br />

P1C66ML250ATST 11-19<br />

P1C66ML400ATSN 11-19<br />

P1C66NB125ATST 11-19<br />

P1C66QR225ATST 11-19<br />

P1CONACPHCU 11-11, 11-23<br />

P1CONBPHAL 11-11, 11-23<br />

P1CONBPHCU 11-11, 11-23<br />

P1E18BD100ATS 11-19<br />

P1E18BD100ATST 11-19<br />

P1E18FX225ATST 11-19<br />

P1E18FX250ATS 11-19<br />

P1E18FX250ATST 11-19<br />

P1E18JX400ATS 11-19<br />

P1E18MC250A 11-10<br />

P1E18MC250AT 11-10<br />

P1E18MC250C 11-10<br />

P1E18MC250CT 11-10<br />

P1E18MC400A 11-10<br />

P1E18MC400C 11-10<br />

P1E18ML125ATS 11-19<br />

P1E18ML125ATST 11-19<br />

P1E18ML250ATS 11-19<br />

P1E18ML250ATST 11-19<br />

P1E18ML400ATS 11-19<br />

P1E18NB125ATS 11-19<br />

P1E18NB125ATST 11-19<br />

P1E30BD100ATS 11-19<br />

P1E30BD100ATST 11-19<br />

P1E30FX225ATST 11-19<br />

P1E30FX250ATS 11-19<br />

P1E30FX250ATST 11-19<br />

P1E30JX400ATS 11-19<br />

P1E30JX400ATST 11-19<br />

P1E30MC250A 11-10<br />

P1E30MC250AT 11-10<br />

P1E30MC250C 11-10<br />

P1E30MC250CT 11-10<br />

P1E30MC400A 11-10<br />

P1E30MC400AT 11-10<br />

P1E30MC400C 11-10<br />

P1E30MC400CT 11-10<br />

P1E30ML125ATS 11-19<br />

P1E30ML125ATST 11-19<br />

P1E30ML250ATS 11-19<br />

P1E30ML250ATST 11-19<br />

P1E30ML400ATS 11-19<br />

P1E30ML400ATST 11-19<br />

P1E30NB125ATS 11-19<br />

P1E30NB125ATST 11-19<br />

P1E42BD100ATS 11-19<br />

P1E42BD100ATST 11-19<br />

P1E42FX225ATST 11-19<br />

P1E42FX250ATS 11-19<br />

P1E42FX250ATST 11-19<br />

P1E42JX400ATS 11-19<br />

P1E42JX400ATST 11-19<br />

P1E42MC250A 11-10<br />

P1E42MC250AT 11-10<br />

P1E42MC250C 11-10<br />

P1E42MC250CT 11-10<br />

P1E42MC400A 11-10<br />

P1E42MC400AT 11-10<br />

P1E42MC400C 11-10<br />

P1E42MC400CT 11-10<br />

P1E42ML125ATS 11-19<br />

P1E42ML125ATST 11-19<br />

P1E42ML250ATS 11-19<br />

P1E42ML250ATST 11-19<br />

P1E42ML400ATS 11-19<br />

P1E42ML400ATST 11-19<br />

P1E42NB125ATS 11-19<br />

P1E42NB125ATST 11-19<br />

P1E54BD100ATST 11-19<br />

P1E54FX225ATST 11-19<br />

P1E54FX250ATST 11-19<br />

P1E54JX400ATST 11-19<br />

P1E54MC250AT 11-10<br />

P1E54MC250CT 11-10<br />

P1E54MC400AT 11-10<br />

P1E54MC400CT 11-10<br />

P1E54ML125ATST 11-19<br />

P1E54ML250ATST 11-19<br />

P1E54ML400ATST 11-19<br />

P1E54NB125ATST 11-19<br />

P1E66BD100ATST 11-19<br />

P1E66FX225ATST 11-19<br />

P1E66FX250ATST 11-19<br />

P1E66JX400ATSN 11-19<br />

P1E66ML125ATST 11-19<br />

P1E66ML250ATST 11-19<br />

P1E66ML400ATSN 11-19<br />

P1E66NB125ATST 11-19<br />

P1SCRWS 11-11, 11-23<br />

P1X18MC250A 11-10<br />

P1X18MC250AT 11-10<br />

P1X18MC250C 11-10<br />

P1X18MC250CT 11-10<br />

P1X18MC400A 11-10<br />

P1X18MC400C 11-10<br />

P1X30MC250A 11-10<br />

P1X30MC250AT 11-10<br />

P1X30MC250C 11-10<br />

P1X30MC250CT 11-10<br />

P1X30MC400A 11-10<br />

P1X30MC400AT 11-10<br />

P1X30MC400C 11-10<br />

P1X30MC400CT 11-10<br />

P1X42MC250A 11-10<br />

P1X42MC250AT 11-10<br />

P1X42MC250C 11-10<br />

P1X42MC250CT 11-10<br />

P1X42MC400A 11-10<br />

P1X42MC400AT 11-10<br />

P1X42MC400C 11-10<br />

P1X42MC400CT 11-10<br />

P1X54MC250AT 11-10<br />

P1X54MC250CT 11-10<br />

P1X54MC400AT 11-10<br />

P1X54MC400CT 11-10<br />

P2442B3150CU 1-13<br />

P2442L3200CU 1-13<br />

P2A18BL100ATS 11-32<br />

P2A18BQ125ATS 11-32<br />

P2A18FX250ATS 11-32<br />

P2A18JX400ATS 11-32<br />

P2A18LX600ATS 11-32<br />

P2A18ML125ATS 11-32<br />

P2A18ML250ATS 11-32<br />

P2A18ML400ATS 11-32<br />

P2A18ML600ATS 11-32<br />

P2A18QR225ATS 11-32<br />

P2A30BL100ATS 11-32<br />

P2A30BQ125ATS 11-32<br />

P2A30FX250ATS 11-32<br />

P2A30JX400ATS 11-32<br />

P2A30LX600ATS 11-32<br />

P2A30ML125ATS 11-32<br />

P2A30ML250ATS 11-32<br />

P2A30ML400ATS 11-32<br />

P2A30ML600ATS 11-32<br />

P2A30QR225ATS 11-32<br />

P2A42BL100ATS 11-32<br />

P2A42BQ125ATS 11-32<br />

P2A42FX250ATS 11-32<br />

P2A42JX400ATS 11-32<br />

P2A42LX600ATS 11-32<br />

P2A42ML125ATS 11-32<br />

P2A42ML250ATS 11-32<br />

P2A42ML400ATS 11-32<br />

P2A42ML600ATS 11-32<br />

P2A42QR225ATS 11-32<br />

P2A54BL100ATS 11-32<br />

P2A54BQ125ATS 11-32<br />

P2A54FX250ATS 11-32<br />

P2A54JX400ATS 11-32<br />

P2A54LX600ATS 11-32<br />

P2A54ML125ATS 11-32<br />

P2A54ML250ATS 11-32<br />

P2A54ML400ATS 11-32<br />

P2A54ML600ATS 11-32<br />

P2A54QR225ATS 11-32<br />

P2A66BQ125ATS 11-32<br />

P2A66FX250ATS 11-32<br />

P2A66JX400ATS 11-32<br />

P2A66ML125ATS 11-32<br />

P2A66ML250ATS 11-32<br />

P2A66ML400ATS 11-32<br />

P2A66ML600ATS 11-32<br />

P2A66QR225ATS 11-32<br />

P2A78BQ125ATS 11-32<br />

P2A78FX250ATS 11-32<br />

P2A78ML125ATS 11-32<br />

P2A78ML250ATS 11-32<br />

P2A78ML400ATS 11-32<br />

P2A78ML600ATS 11-32<br />

P2A78QR225ATS 11-32<br />

P2A90BQ125ATS 11-32<br />

P2A90ML125ATS 11-32<br />

P2A90ML250ATS 11-32<br />

P2A90ML400ATS 11-32<br />

P2A90ML600ATS 11-32<br />

P2A90QR225ATS 11-32<br />

P2BK1 11-38<br />

P2BK2 11-38<br />

P2BK3 11-38<br />

P2C18BL100ATS 11-32<br />

P2C18FX250ATS 11-32<br />

P2C18JX400ATS 11-32<br />

P2C18LX600ATS 11-32<br />

P2C18ML125ATS 11-32<br />

P2C18ML250ATS 11-32<br />

P2C18ML400ATS 11-32<br />

P2C18ML600ATS 11-32<br />

P2C18NB125ATS 11-32<br />

P2C18QR225ATS 11-32<br />

P2C30BL100ATS 11-32<br />

P2C30FX250ATS 11-32<br />

P2C30JX400ATS 11-32<br />

P2C30LX600ATS 11-32<br />

P2C30ML125ATS 11-32<br />

P2C30ML250ATS 11-32<br />

P2C30ML400ATS 11-32<br />

P2C30ML600ATS 11-32<br />

P2C30NB125ATS 11-32<br />

P2C30QR225ATS 11-32<br />

P2C42BL100ATS 11-32<br />

P2C42FX250ATS 11-32<br />

P2C42JX400ATS 11-32<br />

P2C42LX600ATS 11-32<br />

P2C42ML125ATS 11-32<br />

P2C42ML250ATS 11-32<br />

P2C42ML400ATS 11-32<br />

P2C42ML600ATS 11-32<br />

P2C42NB125ATS 11-32<br />

P2C42QR225ATS 11-32<br />

P2C54BL100ATS 11-32<br />

P2C54FX250ATS 11-32<br />

P2C54JX400ATS 11-32<br />

P2C54LX600ATS 11-32<br />

P2C54ML125ATS 11-32<br />

P2C54ML250ATS 11-32<br />

P2C54ML400ATS 11-32<br />

P2C54ML600ATS 11-32<br />

P2C54NB125ATS 11-32<br />

P2C54QR225ATS 11-32<br />

P2C66FX250ATS 11-32<br />

P2C66JX400ATS 11-32<br />

P2C66ML125ATS 11-32<br />

P2C66ML250ATS 11-32<br />

P2C66ML400ATS 11-32<br />

P2C66ML600ATS 11-32<br />

P2C66NB125ATS 11-32<br />

P2C66QR225ATS 11-32<br />

P2C78FX250ATS 11-32<br />

P2C78ML125ATS 11-32<br />

P2C78ML250ATS 11-32<br />

P2C78ML400ATS 11-32<br />

P2C78ML600ATS 11-32<br />

P2C78NB125ATS 11-32<br />

P2C78QR225ATS 11-32<br />

P2C90ML125ATS 11-32<br />

P2C90ML250ATS 11-32<br />

P2C90ML400ATS 11-32<br />

P2C90ML600ATS 11-32<br />

P2C90NB125ATS 11-32<br />

P2C90QR225ATS 11-32<br />

P2E18BQ100ATS 11-32<br />

P2E18E4125ATS 11-32<br />

P2E18FX225ATS 11-32<br />

P2E18FX250ATS 11-32<br />

P2E18JX400ATS 11-32<br />

P2E18LX600ATS 11-32<br />

P2E18ML125ATS 11-32<br />

P2E18ML250ATS 11-32<br />

P2E18ML400ATS 11-32<br />

P2E18ML600ATS 11-32<br />

P2E30BQ100ATS 11-32<br />

P2E30E4125ATS 11-32<br />

P2E30FX225ATS 11-32<br />

P2E30FX250ATS 11-32<br />

P2E30JX400ATS 11-32<br />

P2E30LX600ATS 11-32<br />

P2E30ML125ATS 11-32<br />

P2E30ML250ATS 11-32<br />

P2E30ML400ATS 11-32<br />

P2E30ML600ATS 11-32<br />

P2E42BQ100ATS 11-32<br />

P2E42E4125ATS 11-32<br />

P2E42FX225ATS 11-32<br />

P2E42FX250ATS 11-32<br />

P2E42JX400ATS 11-32<br />

P2E42LX600ATS 11-32<br />

P2E42ML125ATS 11-32<br />

P2E42ML250ATS 11-32<br />

P2E42ML400ATS 11-32<br />

P2E42ML600ATS 11-32<br />

P2E54BQ100ATS 11-32<br />

P2E54E4125ATS 11-32<br />

P2E54FX225ATS 11-32<br />

P2E54FX250ATS 11-32<br />

P2E54JX400ATS 11-32<br />

P2E54LX600ATS 11-32<br />

P2E54ML125ATS 11-32<br />

P2E54ML250ATS 11-32<br />

P2E54ML400ATS 11-32<br />

P2E54ML600ATS 11-32<br />

P2E66E4125ATS 11-32<br />

P2E66FX225ATS 11-32<br />

P2E66FX250ATS 11-32<br />

P2E66JX400ATS 11-32<br />

P2E66ML125ATS 11-32<br />

P2E66ML250ATS 11-32<br />

P2E66ML400ATS 11-32<br />

P2E66ML600ATS 11-32<br />

P2E78E4125ATS 11-32<br />

P2E78FX225ATS 11-32<br />

P2E78FX250ATS 11-32<br />

P2E78ML125ATS 11-32<br />

P2E78ML250ATS 11-32<br />

P2E78ML400ATS 11-32<br />

P2E78ML600ATS 11-32<br />

P2E90E4125ATS 11-32<br />

P2E90ML125ATS 11-32<br />

P2E90ML250ATS 11-32<br />

P2E90ML400ATS 11-32<br />

P2E90ML600ATS 11-32<br />

P30EM Series Empty Enclosure 17-334<br />

P3030B3125CU 1-13<br />

P3042B3100CU 1-13<br />

P3054B3200CU 1-13<br />

P3054L3200CU 1-13<br />

P3A56FD250ATS 11-45<br />

P3A56JD400ATS 11-45<br />

P3A56LD600ATS 11-45<br />

P3A56ML250ATS 11-44<br />

P3A56ML400ATS 11-44<br />

P3A56ML600ATS 11-44<br />

P3A56ML800ATS 11-44<br />

P3A62FD250ATS 11-45<br />

P3A62JD400ATS 11-45<br />

P3A62LD600ATS 11-45<br />

P3A62ML250ATS 11-44<br />

P3A62ML400ATS 11-44<br />

P3A62ML600ATS 11-44<br />

P3A62ML800ATS 11-44<br />

P3A68FD250ATS 11-45<br />

P3A68JD400ATS 11-45<br />

P3A68LD600ATS 11-45<br />

P3A68ML250ATS 11-44<br />

P3A68ML400ATS 11-44<br />

P3A68ML600ATS 11-44<br />

P3A68ML800ATS 11-44<br />

P3A74FD250ATS 11-45<br />

P3A74JD400ATS 11-45<br />

P3A74LD600ATS 11-45<br />

P3A74ML250ATS 11-44<br />

P3A74ML400ATS 11-44<br />

P3A74ML600ATS 11-44<br />

P3A74ML800ATS 11-44<br />

P3A80FD250ATS 11-45<br />

P3A80JD400ATS 11-45<br />

P3A80LD600ATS 11-45<br />

P3A80ML250ATS 11-44<br />

P3A80ML400ATS 11-44<br />

P3A80ML600ATS 11-44<br />

P3A80ML800ATS 11-44<br />

I<br />

PRODUCT<br />

INDEX<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog I-21


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

I<br />

PRODUCT<br />

INDEX<br />

P3B56FD250ATS 11-45<br />

P3B56JD400ATS 11-45<br />

P3B56LD600ATS 11-45<br />

P3B56ML250ATS 11-44<br />

P3B56ML400ATS 11-44<br />

P3B56ML600ATS 11-44<br />

P3B56ML800ATS 11-44<br />

P3B62FD250ATS 11-45<br />

P3B62JD400ATS 11-45<br />

P3B62LD600ATS 11-45<br />

P3B62ML250ATS 11-44<br />

P3B62ML400ATS 11-44<br />

P3B62ML600ATS 11-44<br />

P3B62ML800ATS 11-44<br />

P3B68FD250ATS 11-45<br />

P3B68JD400ATS 11-45<br />

P3B68LD600ATS 11-45<br />

P3B68ML250ATS 11-44<br />

P3B68ML400ATS 11-44<br />

P3B68ML600ATS 11-44<br />

P3B68ML800ATS 11-44<br />

P3B74FD250ATS 11-45<br />

P3B74JD400ATS 11-45<br />

P3B74LD600ATS 11-45<br />

P3B74ML250ATS 11-44<br />

P3B74ML400ATS 11-44<br />

P3B74ML600ATS 11-44<br />

P3B74ML800ATS 11-44<br />

P3B80FD250ATS 11-45<br />

P3B80JD400ATS 11-45<br />

P3B80LD600ATS 11-45<br />

P3B80ML250ATS 11-44<br />

P3B80ML400ATS 11-44<br />

P3B80ML600ATS 11-44<br />

P3B80ML800ATS 11-44<br />

P3BK1 11-49<br />

P3C56FD250ATS 11-45<br />

P3C56JD400ATS 11-45<br />

P3C56LD600ATS 11-45<br />

P3C56ML250ATS 11-44<br />

P3C56ML400ATS 11-44<br />

P3C56ML600ATS 11-44<br />

P3C56ML800ATS 11-44<br />

P3C62FD250ATS 11-45<br />

P3C62JD400ATS 11-45<br />

P3C62LD600ATS 11-45<br />

P3C62ML250ATS 11-44<br />

P3C62ML400ATS 11-44<br />

P3C62ML600ATS 11-44<br />

P3C62ML800ATS 11-44<br />

P3C68FD250ATS 11-45<br />

P3C68JD400ATS 11-45<br />

P3C68LD600ATS 11-45<br />

P3C68ML250ATS 11-44<br />

P3C68ML400ATS 11-44<br />

P3C68ML600ATS 11-44<br />

P3C68ML800ATS 11-44<br />

P3C74FD250ATS 11-45<br />

P3C74JD400ATS 11-45<br />

P3C74LD600ATS 11-45<br />

P3C74ML250ATS 11-44<br />

P3C74ML400ATS 11-44<br />

P3C74ML600ATS 11-44<br />

P3C74ML800ATS 11-44<br />

P3C80FD250ATS 11-45<br />

P3C80JD400ATS 11-45<br />

P3C80LD600ATS 11-45<br />

P3C80ML250ATS 11-44<br />

P3C80ML400ATS 11-44<br />

P3C80ML600ATS 11-44<br />

P3C80ML800ATS 11-44<br />

P3D56FD250ATS 11-45<br />

P3D56JD400ATS 11-45<br />

P3D56LD600ATS 11-45<br />

P3D56ML250ATS 11-44<br />

P3D56ML400ATS 11-44<br />

P3D56ML600ATS 11-44<br />

P3D56ML800ATS 11-44<br />

P3D62FD250ATS 11-45<br />

P3D62JD400ATS 11-45<br />

P3D62LD600ATS 11-45<br />

P3D62ML250ATS 11-44<br />

P3D62ML400ATS 11-44<br />

P3D62ML600ATS 11-44<br />

P3D62ML800ATS 11-44<br />

P3D68FD250ATS 11-45<br />

P3D68JD400ATS 11-45<br />

P3D68LD600ATS 11-45<br />

P3D68ML250ATS 11-44<br />

P3D68ML400ATS 11-44<br />

P3D68ML600ATS 11-44<br />

P3D68ML800ATS 11-44<br />

P3D74FD250ATS 11-45<br />

P3D74JD400ATS 11-45<br />

P3D74LD600ATS 11-45<br />

P3D74ML250ATS 11-44<br />

P3D74ML400ATS 11-44<br />

P3D74ML600ATS 11-44<br />

P3D74ML800ATS 11-44<br />

P3D80FD250ATS 11-45<br />

P3D80JD400ATS 11-45<br />

P3D80LD600ATS 11-45<br />

P3D80ML250ATS 11-44<br />

P3D80ML400ATS 11-44<br />

P3D80ML600ATS 11-44<br />

P3D80ML800ATS 11-44<br />

P3E56FD250ATS 11-45<br />

P3E56JD400ATS 11-45<br />

P3E56LD600ATS 11-45<br />

P3E56ML250ATS 11-44<br />

P3E56ML400ATS 11-44<br />

P3E56ML600ATS 11-44<br />

P3E56ML800ATS 11-44<br />

P3E62FD250ATS 11-45<br />

P3E62JD400ATS 11-45<br />

P3E62LD600ATS 11-45<br />

P3E62ML250ATS 11-44<br />

P3E62ML400ATS 11-44<br />

P3E62ML600ATS 11-44<br />

P3E62ML800ATS 11-44<br />

P3E68FD250ATS 11-45<br />

P3E68JD400ATS 11-45<br />

P3E68LD600ATS 11-45<br />

P3E68ML250ATS 11-44<br />

P3E68ML400ATS 11-44<br />

P3E68ML600ATS 11-44<br />

P3E68ML800ATS 11-44<br />

P3E74FD250ATS 11-45<br />

P3E74JD400ATS 11-45<br />

P3E74LD600ATS 11-45<br />

P3E74ML250ATS 11-44<br />

P3E74ML400ATS 11-44<br />

P3E74ML600ATS 11-44<br />

P3E74ML800ATS 11-44<br />

P3E80FD250ATS 11-45<br />

P3E80JD400ATS 11-45<br />

P3E80LD600ATS 11-45<br />

P3E80ML250ATS 11-44<br />

P3E80ML400ATS 11-44<br />

P3E80ML600ATS 11-44<br />

P3E80ML800ATS 11-44<br />

P3F56 11-49<br />

P3F56FD250ATS 11-45<br />

P3F56JD400ATS 11-45<br />

P3F56LD600ATS 11-45<br />

P3F56ML250ATS 11-44<br />

P3F56ML400ATS 11-44<br />

P3F56ML600ATS 11-44<br />

P3F56ML800ATS 11-44<br />

P3F62 11-49<br />

P3F62FD250ATS 11-45<br />

P3F62JD400ATS 11-45<br />

P3F62LD600ATS 11-45<br />

P3F62ML250ATS 11-44<br />

P3F62ML400ATS 11-44<br />

P3F62ML600ATS 11-44<br />

P3F62ML800ATS 11-44<br />

P3F68 11-49<br />

P3F68FD250ATS 11-45<br />

P3F68JD400ATS 11-45<br />

P3F68LD600ATS 11-45<br />

P3F68ML250ATS 11-44<br />

P3F68ML400ATS 11-44<br />

P3F68ML600ATS 11-44<br />

P3F68ML800ATS 11-44<br />

P3F74 11-49<br />

P3F74FD250ATS 11-45<br />

P3F74JD400ATS 11-45<br />

P3F74LD600ATS 11-45<br />

P3F74ML250ATS 11-44<br />

P3F74ML400ATS 11-44<br />

P3F74ML600ATS 11-44<br />

P3F74ML800ATS 11-44<br />

P3F80 11-49<br />

P3F80FD250ATS 11-45<br />

P3F80JD400ATS 11-45<br />

P3F80LD600ATS 11-45<br />

P3F80ML250ATS 11-44<br />

P3F80ML400ATS 11-44<br />

P3F80ML600ATS 11-44<br />

P3F80ML800ATS 11-44<br />

P3S56 11-49<br />

P3S62 11-49<br />

P3S68 11-49<br />

P3S74 11-49<br />

P3S80 11-49<br />

P4242B3150CU 1-13<br />

P4260B3200CU 1-13<br />

P4260B3225CU 1-13<br />

P4260B3225TCU 1-13<br />

P4260L3225CU 1-13<br />

P460NV 11-82<br />

P460NVD 11-82<br />

P460NVDD 11-82<br />

P460NVHG 11-82<br />

P460NVV 11-82<br />

P460NVVHG 11-82<br />

P460V 11-82<br />

P460VD 11-82<br />

P460VDD 11-82<br />

P460VHG 11-82<br />

P460VV 11-82<br />

P460VVHG 11-82<br />

P475NV 11-82<br />

P475NVD 11-82<br />

P475NVDD 11-82<br />

P475NVHG 11-82<br />

P475NVV 11-82<br />

P475NVVHG 11-82<br />

P475V 11-82<br />

P475VD 11-82<br />

P475VDD 11-82<br />

P475VHG 11-82<br />

P475VV 11-82<br />

P475VVHG 11-82<br />

P490NV 11-82<br />

P490NVD 11-82<br />

P490NVDD 11-82<br />

P490NVHG 11-82<br />

P490NVV 11-82<br />

P490NVVHG 11-82<br />

P490V 11-82<br />

P490VD 11-82<br />

P490VDD 11-82<br />

P490VHG 11-82<br />

P490VV 11-82<br />

P490VVHG 11-82<br />

P4A60JX400ATS 11-73<br />

P4A60LX600ATS 11-73<br />

P4A60M1800ATS 11-73<br />

P4A60ML101ATS 11-73<br />

P4A60ML120ATS 11-73<br />

P4A60ML400ATS 11-73<br />

P4A60ML600ATS 11-73<br />

P4A60ML800ATS 11-73<br />

P4A75JX400ATS 11-73<br />

P4A75LX600ATS 11-73<br />

P4A75M1800ATS 11-73<br />

P4A75ML101ATS 11-73<br />

P4A75ML120ATS 11-73<br />

P4A75ML400ATS 11-73<br />

P4A75ML600ATS 11-73<br />

P4A75ML800ATS 11-73<br />

P4A90JX400ATS 11-73<br />

P4A90LX600ATS 11-73<br />

P4A90M1800ATS 11-73<br />

P4A90ML101ATS 11-73<br />

P4A90ML120ATS 11-73<br />

P4A90ML400ATS 11-73<br />

P4A90ML600ATS 11-73<br />

P4A90ML800ATS 11-73<br />

P4B60JX400ATS 11-73<br />

P4B60LX600ATS 11-73<br />

P4B60M1800ATS 11-73<br />

P4B60ML101ATS 11-73<br />

P4B60ML120ATS 11-73<br />

P4B60ML400ATS 11-73<br />

P4B60ML600ATS 11-73<br />

P4B60ML800ATS 11-73<br />

P4B75JX400ATS 11-73<br />

P4B75LX600ATS 11-73<br />

P4B75M1800ATS 11-73<br />

P4B75ML101ATS 11-73<br />

P4B75ML120ATS 11-73<br />

P4B75ML400ATS 11-73<br />

P4B75ML600ATS 11-73<br />

P4B75ML800ATS 11-73<br />

P4B90JX400ATS 11-73<br />

P4B90LX600ATS 11-73<br />

P4B90M1800ATS 11-73<br />

P4B90ML101ATS 11-73<br />

P4B90ML120ATS 11-73<br />

P4B90ML400ATS 11-73<br />

P4B90ML600ATS 11-73<br />

P4B90ML800ATS 11-73<br />

P4C60JX400ATS 11-73<br />

P4C60LX600ATS 11-73<br />

P4C60M1800ATS 11-73<br />

P4C60ML101ATS 11-73<br />

P4C60ML120ATS 11-73<br />

P4C60ML400ATS 11-73<br />

P4C60ML600ATS 11-73<br />

P4C60ML800ATS 11-73<br />

P4C75JX400ATS 11-73<br />

P4C75LX600ATS 11-73<br />

P4C75M1800ATS 11-73<br />

P4C75ML101ATS 11-73<br />

P4C75ML120ATS 11-73<br />

P4C75ML400ATS 11-73<br />

P4C75ML600ATS 11-73<br />

P4C75ML800ATS 11-73<br />

P4C90JX400ATS 11-73<br />

P4C90LX600ATS 11-73<br />

P4C90M1800ATS 11-73<br />

P4C90ML101ATS 11-73<br />

P4C90ML120ATS 11-73<br />

P4C90ML400ATS 11-73<br />

P4C90ML600ATS 11-73<br />

P4C90ML800ATS 11-73<br />

P4D60JX400ATS 11-73<br />

P4D60LX600ATS 11-73<br />

P4D60M1800ATS 11-73<br />

P4D60ML101ATS 11-73<br />

P4D60ML120ATS 11-73<br />

P4D60ML400ATS 11-73<br />

P4D60ML600ATS 11-73<br />

P4D60ML800ATS 11-73<br />

P4D75JX400ATS 11-73<br />

P4D75LX600ATS 11-73<br />

P4D75M1800ATS 11-73<br />

P4D75ML101ATS 11-73<br />

P4D75ML120ATS 11-73<br />

P4D75ML400ATS 11-73<br />

P4D75ML600ATS 11-73<br />

P4D75ML800ATS 11-73<br />

P4D90JX400ATS 11-73<br />

P4D90LX600ATS 11-73<br />

P4D90M1800ATS 11-73<br />

P4D90ML101ATS 11-73<br />

P4D90ML120ATS 11-73<br />

P4D90ML400ATS 11-73<br />

P4D90ML600ATS 11-73<br />

P4D90ML800ATS 11-73<br />

P4E60JX400ATS 11-73<br />

P4E60LX600ATS 11-73<br />

P4E60M1800ATS 11-73<br />

P4E60ML101ATS 11-73<br />

P4E60ML120ATS 11-73<br />

P4E60ML400ATS 11-73<br />

P4E60ML600ATS 11-73<br />

P4E60ML800ATS 11-73<br />

P4E75JX400ATS 11-73<br />

P4E75LX600ATS 11-73<br />

P4E75M1800ATS 11-73<br />

P4E75ML101ATS 11-73<br />

P4E75ML120ATS 11-73<br />

P4E75ML400ATS 11-73<br />

P4E75ML600ATS 11-73<br />

P4E75ML800ATS 11-73<br />

P4E90JX400ATS 11-73<br />

P4E90LX600ATS 11-73<br />

P4E90M1800ATS 11-73<br />

P4E90ML101ATS 11-73<br />

P4E90ML120ATS 11-73<br />

P4E90ML400ATS 11-73<br />

P4E90ML600ATS 11-73<br />

P4E90ML800ATS 11-73<br />

P4F60JX400ATS 11-73<br />

P4F60LX600ATS 11-73<br />

P4F60M1800ATS 11-73<br />

P4F60ML101ATS 11-73<br />

P4F60ML120ATS 11-73<br />

P4F60ML400ATS 11-73<br />

P4F60ML600ATS 11-73<br />

P4F60ML800ATS 11-73<br />

P4F75JX400ATS 11-73<br />

P4F75LX600ATS 11-73<br />

P4F75M1800ATS 11-73<br />

P4F75ML101ATS 11-73<br />

P4F75ML120ATS 11-73<br />

P4F75ML400ATS 11-73<br />

P4F75ML600ATS 11-73<br />

P4F75ML800ATS 11-73<br />

P4F90JX400ATS 11-73<br />

P4F90LX600ATS 11-73<br />

P4F90M1800ATS 11-73<br />

P4F90ML101ATS 11-73<br />

P4F90ML120ATS 11-73<br />

P4F90ML400ATS 11-73<br />

P4F90ML600ATS 11-73<br />

P4F90ML800ATS 11-73<br />

P5470B3225CU 1-13<br />

P5470L3225CU 1-13<br />

P560NV 11-96<br />

P560NVD 11-96<br />

P560NVDD 11-96<br />

P560NVHG 11-96<br />

P560V 11-96<br />

P560VD 11-96<br />

P560VDD 11-96<br />

P560VHG 11-96<br />

P575NV 11-96<br />

P575NVD 11-96<br />

P575NVDD 11-96<br />

P575NVHG 11-96<br />

P575V 11-96<br />

P575VD 11-96<br />

P575VDD 11-96<br />

P575VHG 11-96<br />

P590NVD 11-96<br />

P590NVDD 11-96<br />

P590NVHG 11-96<br />

P590V 11-96<br />

P590VD 11-96<br />

P590VDD 11-96<br />

P590VHG 11-96<br />

P5A60M1800ATS 11-86<br />

P5A60ML101ATS 11-86<br />

P5A60ML120ATS 11-86<br />

P5A60ML800ATS 11-86<br />

P5A60N1120ATS 11-86<br />

P5A75M1800ATS 11-86<br />

P5A75ML101ATS 11-86<br />

P5A75ML120ATS 11-86<br />

P5A75ML800ATS 11-86<br />

P5A75MS120ATS 11-87<br />

P5A75MS400ATS 11-87<br />

P5A75MS600ATS 11-87<br />

P5A75MS800ATS 11-87<br />

P5A75N1120ATS 11-86<br />

P5A90M1800ATS 11-86<br />

P5A90ML101ATS 11-86<br />

P5A90ML120ATS 11-86<br />

P5A90ML800ATS 11-86<br />

P5A90MS120ATS 11-87<br />

P5A90MS400ATS 11-87<br />

P5A90MS600ATS 11-87<br />

P5A90MS800ATS 11-87<br />

P5A90N1120ATS 11-86<br />

P5B60M1800ATS 11-86<br />

P5B60ML101ATS 11-86<br />

P5B60ML120ATS 11-86<br />

P5B60ML800ATS 11-86<br />

P5B60N1120ATS 11-86<br />

P5B75M1800ATS 11-86<br />

P5B75ML101ATS 11-86<br />

P5B75ML120ATS 11-86<br />

P5B75ML800ATS 11-86<br />

P5B75MS120ATS 11-87<br />

P5B75MS400ATS 11-87<br />

P5B75MS600ATS 11-87<br />

P5B75MS800ATS 11-87<br />

P5B75N1120ATS 11-86<br />

P5B90M1800ATS 11-86<br />

P5B90ML101ATS 11-86<br />

P5B90ML120ATS 11-86<br />

P5B90ML800ATS 11-86<br />

P5B90MS120ATS 11-87<br />

P5B90MS400ATS 11-87<br />

P5B90MS600ATS 11-87<br />

P5B90MS800ATS 11-87<br />

P5B90N1120ATS 11-86<br />

P5C60M1800ATS 11-86<br />

P5C60ML101ATS 11-86<br />

P5C60ML120ATS 11-86<br />

P5C60ML800ATS 11-86<br />

P5C60N1120ATS 11-86<br />

P5C75M1800ATS 11-86<br />

P5C75ML101ATS 11-86<br />

P5C75ML120ATS 11-86<br />

I-22<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

P5C75ML800ATS 11-86<br />

P5C75MS120ATS 11-87<br />

P5C75MS400ATS 11-87<br />

P5C75MS600ATS 11-87<br />

P5C75MS800ATS 11-87<br />

P5C75N1120ATS 11-86<br />

P5C90M1800ATS 11-86<br />

P5C90ML101ATS 11-86<br />

P5C90ML120ATS 11-86<br />

P5C90ML800ATS 11-86<br />

P5C90MS120ATS 11-87<br />

P5C90MS400ATS 11-87<br />

P5C90MS600ATS 11-87<br />

P5C90MS800ATS 11-87<br />

P5C90N1120ATS 11-86<br />

P5D60M1800ATS 11-86<br />

P5D60ML101ATS 11-86<br />

P5D60ML120ATS 11-86<br />

P5D60ML800ATS 11-86<br />

P5D60N1120ATS 11-86<br />

P5D75M1800ATS 11-86<br />

P5D75ML101ATS 11-86<br />

P5D75ML120ATS 11-86<br />

P5D75ML800ATS 11-86<br />

P5D75MS120ATS 11-87<br />

P5D75MS400ATS 11-87<br />

P5D75MS600ATS 11-87<br />

P5D75MS800ATS 11-87<br />

P5D75N1120ATS 11-86<br />

P5D90M1800ATS 11-86<br />

P5D90ML101ATS 11-86<br />

P5D90ML120ATS 11-86<br />

P5D90ML800ATS 11-86<br />

P5D90MS120ATS 11-87<br />

P5D90MS400ATS 11-87<br />

P5D90MS600ATS 11-87<br />

P5D90MS800ATS 11-87<br />

P5D90N1120ATS 11-86<br />

P5E60M1800ATS 11-86<br />

P5E60ML101ATS 11-86<br />

P5E60ML120ATS 11-86<br />

P5E60ML800ATS 11-86<br />

P5E60N1120ATS 11-86<br />

P5E75M1800ATS 11-86<br />

P5E75ML101ATS 11-86<br />

P5E75ML120ATS 11-86<br />

P5E75ML800ATS 11-86<br />

P5E75MS120ATS 11-87<br />

P5E75MS400ATS 11-87<br />

P5E75MS600ATS 11-87<br />

P5E75MS800ATS 11-87<br />

P5E75N1120ATS 11-86<br />

P5E90M1800ATS 11-86<br />

P5E90ML101ATS 11-86<br />

P5E90ML120ATS 11-86<br />

P5E90ML800ATS 11-86<br />

P5E90MS120ATS 11-87<br />

P5E90MS400ATS 11-87<br />

P5E90MS600ATS 11-87<br />

P5E90MS800ATS 11-87<br />

P5E90N1120ATS 11-86<br />

P5F60M1800ATS 11-86<br />

P5F60ML101ATS 11-86<br />

P5F60ML120ATS 11-86<br />

P5F60ML800ATS 11-86<br />

P5F60N1120ATS 11-86<br />

P5F75M1800ATS 11-86<br />

P5F75ML101ATS 11-86<br />

P5F75ML120ATS 11-86<br />

P5F75ML800ATS 11-86<br />

P5F75MS120ATS 11-87<br />

P5F75MS400ATS 11-87<br />

P5F75MS600ATS 11-87<br />

P5F75MS800ATS 11-87<br />

P5F75N1120ATS 11-86<br />

P5F90M1800ATS 11-86<br />

P5F90ML101ATS 11-86<br />

P5F90ML120ATS 11-86<br />

P5F90ML800ATS 11-86<br />

P5F90MS120ATS 11-87<br />

P5F90MS400ATS 11-87<br />

P5F90MS600ATS 11-87<br />

P5F90MS800ATS 11-87<br />

P5F90N1120ATS 11-86<br />

PAKMCVRL 3-138<br />

PAKMCVRR 3-138<br />

PB224 13-17<br />

PB226 13-17<br />

PB228 13-17<br />

PB424 13-17<br />

PB426 13-17<br />

PB428 13-17<br />

PB444 13-17<br />

PB446 13-17<br />

PB448 13-17<br />

PB60 11-82<br />

PB75 11-82<br />

PB860 11-96<br />

PB875 11-96<br />

PB890 11-96<br />

PB90 11-82<br />

PBD860 11-96<br />

PBD875 11-96<br />

PBD890 11-96<br />

PBP32 13-20<br />

PC2637 7-165<br />

PC2638 7-165<br />

PC2657 7-165<br />

PC2658 7-165<br />

PC4753 7-165<br />

PC4754 7-165<br />

PC5660 7-165<br />

PC5661 7-165<br />

PC5662 7-165<br />

PC5663 7-165<br />

PC5664 7-165<br />

PC5666 7-165<br />

PC5777 7-165<br />

PC5778 7-165<br />

PCCJD 7-165<br />

PCCLD 7-165<br />

PD63B120 7-136, 7-145<br />

PD63B140 7-136, 7-145<br />

PD63B160 7-136, 7-145<br />

PD63F160 7-136<br />

PD63T120 7-136<br />

PD63T140 7-136<br />

PD63T160 7-136<br />

PDS-CTHC-024 9-24<br />

PDS-CTHC-034 9-24<br />

PDS-CTHC-044 9-24<br />

PDS-CTHC-064 9-24<br />

PDS-CTHC-084 9-24<br />

PDS-CTHC-206 9-24<br />

PDS-CTHC-306 9-24<br />

PDS-CTHC-406 9-24<br />

PDS-CTRC-012 9-25<br />

PDS-CTRC-021 9-25<br />

PDS-CTRC-022 9-25<br />

PDS-CTRC-031 9-25<br />

PDS-CTRC-032 9-25<br />

PDS-CTRC-041 9-25<br />

PDS-CTRC-042 9-25<br />

PDS-CTRC-051 9-25<br />

PDS-CTRC-061 9-25<br />

PDS-CTRC-081 9-25<br />

PDS-CTRC-084 9-25<br />

PDS-CTRC-101 9-25<br />

PDS-CTRC-104 9-25<br />

PDS-CTRC-124 9-25<br />

PDS-CTRC-164 9-25<br />

PDS-CTRC-204 9-25<br />

PDS-CTRC-326 9-25<br />

PDS-CTRC-426 9-25<br />

PDS-CTSC-013 9-24<br />

PDS-CTSC-021 9-24<br />

PDS-CTSC-031 9-24<br />

PDS-CTSC-03R 9-24<br />

PDS-CTSC-042 9-24<br />

PDS-CTSC-062 9-24<br />

PDS-CTSC-083 9-24<br />

PDS-CTSC-123 9-24<br />

PDS-CTSC-163 9-24<br />

PDS-CTSC-200 9-24<br />

PE4630 13-17, 13-18, 13-19<br />

PE4840 13-17, 13-19<br />

PEGB42 13-20<br />

PF224 13-18<br />

PF226 13-18<br />

PF424 13-18<br />

PF426 13-18<br />

PF444 13-18<br />

PF446 13-18<br />

PF4606 13-17, 13-18, 13-19<br />

PF4809 13-17, 13-19<br />

PI1224L3125CU 1-14<br />

PI2442B3150CU 1-14<br />

PI2442L3200CU 1-14<br />

PI3042B3100CU 1-14<br />

PI3054B3200CU 1-14<br />

PI3054L3200CU 1-14<br />

PI4260B3200CU 1-14<br />

PI4260L3225CU 1-14<br />

PI5470B3225CU 1-14<br />

PI5470L3225CU 1-14<br />

PL2616 7-165<br />

PL2617 7-165<br />

PL4762 7-165<br />

PL4763 7-165<br />

PL5680 7-165<br />

PL5796 7-165<br />

PL5797 7-165<br />

PL9698 7-165<br />

PL9699 7-165<br />

PLL44 13-20<br />

PLL46 13-20<br />

PLL48 13-20<br />

PLW10 13-20<br />

PMS13 13-20<br />

PMS15 13-20<br />

PMS5 13-20<br />

PMS6 13-20<br />

PMS8 13-20<br />

PN1212L1125C 1-7<br />

PN1224B1100C 1-6<br />

PN1224L1125C 1-7<br />

PN1224L1200C 1-7<br />

PN1632B1100C 1-6<br />

PN1632L1125C 1-7<br />

PN2020B1100C 1-6<br />

PN2020L1125C 1-7<br />

PN2040B1100C 1-6<br />

PN2040B1150C 1-6<br />

PN2040B1200C 1-6<br />

PN2040L1125C 1-7<br />

PN2040L1150C 1-7<br />

PN2040L1200C 1-7<br />

PN2424B1100C 1-6<br />

PN2448L1125C 1-7<br />

PN2448L1200C 1-7<br />

PN3030B1100C 1-6<br />

PN3030B1125C 1-6<br />

PN3030B1150C 1-6<br />

PN3030L1200C 1-7<br />

PN3048B1200 1-6<br />

PN3048B1200C 1-6<br />

PN3048B1200S14 1-11<br />

PN3048L1125C 1-7<br />

PN3048L1200 1-7<br />

PN3048L1200C 1-7<br />

PN4040B1200 1-6<br />

PN4040B1200C 1-6<br />

PN4040L1125C 1-7<br />

PN4040L1200 1-7<br />

PN4040L1200C 1-7<br />

PN4060B1200 1-6<br />

PN4060B1200C 1-6<br />

PN4060B1200S14 1-11<br />

PN4060L1200C 1-7<br />

PN4264B1225C 1-6<br />

PN4264L1225C 1-7<br />

PN5482B1200C 1-6<br />

PN5482B1225C 1-6<br />

PN5482L1225C 1-7<br />

PNW0816B1150TC 1-6<br />

PNW0816B1200TC 1-6<br />

PNW0816L1200TC 1-7<br />

PNW1212L1125C 1-7<br />

PNW1224B1100C 1-6<br />

PNW1224L1125C 1-7<br />

PNW1224L1200C 1-7<br />

PNW1224L1225C 1-7<br />

PNW1632B1100C 1-6<br />

PNW1632L1125C 1-7<br />

PNW2020B1100C 1-6<br />

PNW2040B1150C 1-6<br />

PNW2040B1200C 1-6<br />

PNW2040L1150C 1-7<br />

PNW2040L1200C 1-7<br />

PNW3048B1100C 1-6<br />

PNW3048B1125C 1-6<br />

PNW3048B1150C 1-6<br />

PNW3048B1200C 1-6<br />

PNW3048L1125C 1-7<br />

PNW3048L1200C 1-7<br />

PNW4040B1200C 1-6<br />

PNW4040L1200C 1-7<br />

PNW4264B1225C 1-6<br />

PNW4264L1225C 1-7<br />

PQ2612 13-17, 13-18, 13-19<br />

PQ2630 13-17, 13-18, 13-19<br />

PQ2816 13-17, 13-19<br />

PQ2840 13-17, 13-19<br />

PQ4612 13-17, 13-18, 13-19<br />

PQ4630 13-17, 13-18, 13-19<br />

PQ4818 13-17, 13-19<br />

PQ4840 13-17, 13-19<br />

PRD6N1 6-8, 7-137<br />

PSDP32 13-20<br />

PSFFJ6 13-19<br />

PSFJL6 13-19<br />

PSP32 13-20<br />

PT1224L3125 1-14<br />

PT2442X3150 1-14<br />

PT2442X3200 1-14<br />

PT3042B3100 1-14<br />

PT3054X3200 1-14<br />

PT4260X3200 1-14<br />

PT4260X3225 1-14<br />

PT5470X3225 1-14<br />

PTE 13-21<br />

PUG14 13-20<br />

PUG26 13-20<br />

PW1224L3125CU 1-13<br />

PW2442L3200CU 1-13<br />

PW3054B3200CU 1-13<br />

PW3054L3200CU 1-13<br />

PW4260B3200CU 1-13<br />

PW4260L3225CU 1-13<br />

PXD63B120 7-136, 7-145<br />

PXD63B140 7-136, 7-145<br />

PXD63B160 7-136, 7-145<br />

PXD63S160A 7-146<br />

Q110 1-41, 7-20<br />

Q1100S 1-43, 7-22<br />

Q115 1-41, 7-20<br />

Q115DFH 1-40, 7-19<br />

Q115DFHH 1-40, 7-19<br />

Q115DFN 1-40, 7-19<br />

Q115H 1-41, 7-20<br />

Q115HH 1-41, 7-20<br />

Q115HID 1-43, 7-22<br />

Q120 1-41, 7-20<br />

Q120DFN 1-40, 7-19<br />

Q120H 1-41, 7-20<br />

Q120HH 1-41, 7-20<br />

Q120HID 1-43, 7-22<br />

Q125 1-41, 7-20<br />

Q125H 1-41, 7-20<br />

Q125HH 1-41, 7-20<br />

Q130 1-41, 7-20<br />

Q130H 1-41, 7-20<br />

Q130HH 1-41, 7-20<br />

Q130HID 1-43, 7-22<br />

Q135 1-41, 7-20<br />

Q135H 1-41, 7-20<br />

Q135HH 1-41, 7-20<br />

Q140 1-41, 7-20<br />

Q140H 1-41, 7-20<br />

Q140HH 1-41, 7-20<br />

Q145 1-41, 7-20<br />

Q145H 1-41, 7-20<br />

Q145HH 1-41, 7-20<br />

Q150 1-41, 7-20<br />

Q150H 1-41, 7-20<br />

Q150HH 1-41, 7-20<br />

Q1515 1-42, 7-21<br />

Q1515NC 1-42, 7-21<br />

Q1520 1-42, 7-21<br />

Q1520NC 1-42, 7-21<br />

Q160 1-41, 7-20<br />

Q160H 1-41, 7-20<br />

Q160HH 1-41, 7-20<br />

Q170 1-41, 7-20<br />

Q170H 1-41, 7-20<br />

Q170HH 1-41, 7-20<br />

Q2020 1-42, 7-21<br />

Q2020NC 1-42, 7-21<br />

Q2030 1-42, 7-21<br />

Q210 1-41, 7-20<br />

Q2100 1-41, 3-135, 7-20<br />

Q2100H 1-41, 3-135, 7-20<br />

Q2100HH 1-41, 3-135, 7-20<br />

Q2110 1-41, 3-135, 7-20<br />

Q2110H 1-41, 3-135, 7-20<br />

Q2110HH 1-41, 3-135, 7-20<br />

Q2125 1-41, 3-135, 7-20<br />

Q2125B 1-45, 7-24<br />

Q2125BH 1-45, 7-24<br />

Q2125H 1-41, 3-135, 7-20<br />

Q2125HH 1-41, 3-135, 7-20<br />

Q2125S 1-43, 7-22<br />

Q215 1-41, 7-20<br />

Q2150B 1-45, 7-24<br />

Q2150BH 1-45, 7-24<br />

Q21515CT 1-42, 7-21<br />

Q21515CT2 1-42, 7-21<br />

Q21520CT 1-42, 7-21<br />

Q21525CT 1-42, 7-21<br />

Q21530CT 1-42, 7-21<br />

Q21530CT2 1-42, 7-21<br />

Q21535CT 1-42, 7-21<br />

Q21540CT 1-42, 7-21<br />

Q21545CT 1-42, 7-21<br />

Q21550CT 1-42, 7-21<br />

Q215AFC 1-40, 7-19<br />

Q215AFCH 1-40, 7-19<br />

Q215AFCN 1-40, 7-19<br />

Q215H 1-41, 7-20<br />

Q215HH 1-41, 7-20<br />

Q215HID 1-43, 7-22<br />

Q215R 1-41, 7-20<br />

Q2175B 1-45, 7-24<br />

Q2175BH 1-45, 7-24<br />

Q220 1-41, 7-20<br />

Q2200B 1-45, 7-24<br />

Q2200BH 1-45, 7-24<br />

Q22020CT 1-42, 7-21<br />

Q22020CT2 1-42, 7-21<br />

Q22025CT 1-42, 7-21<br />

Q22030CT 1-42, 7-21<br />

Q22035CT 1-42, 7-21<br />

Q22040CT 1-42, 7-21<br />

Q22045CT 1-42, 7-21<br />

Q22050CT 1-42, 7-21<br />

Q22050CT2 1-42, 7-21<br />

Q220AFC 1-40, 7-19<br />

Q220AFCH 1-40, 7-19<br />

Q220AFCN 1-40, 7-19<br />

Q220H 1-41, 7-20<br />

Q220HH 1-41, 7-20<br />

Q220HID 1-43, 7-22<br />

Q220R 1-41, 7-20<br />

Q2225B 1-45, 7-24<br />

Q2225BH 1-45, 7-24<br />

Q225 1-41, 7-20<br />

Q225H 1-41, 7-20<br />

Q225HH 1-41, 7-20<br />

Q230 1-41, 7-20<br />

Q23020CT2 1-42, 7-21<br />

Q23025CT2 1-42, 7-21<br />

Q23030CT 1-42, 7-21<br />

Q23030CT2 1-42, 7-21<br />

Q23050CT2 1-42, 7-21<br />

Q230H 1-41, 7-20<br />

Q230HH 1-41, 7-20<br />

Q230HID 1-43, 7-22<br />

Q230R 1-41, 7-20<br />

Q230S 1-43, 7-22<br />

Q235 1-41, 7-20<br />

Q235H 1-41, 7-20<br />

Q235HH 1-41, 7-20<br />

Q240 1-41, 7-20<br />

Q24020CT2 1-42, 7-21<br />

Q24030CT2 1-42, 7-21<br />

Q24040CT2 1-42, 7-21<br />

Q240H 1-41, 7-20<br />

Q240HH 1-41, 7-20<br />

Q240R 1-41, 7-20<br />

Q245 1-41, 7-20<br />

Q245H 1-41, 7-20<br />

Q245HH 1-41, 7-20<br />

Q250 1-41, 7-20<br />

Q250H 1-41, 7-20<br />

Q250HH 1-41, 7-20<br />

Q250NN 1-43, 7-22<br />

Q250R 1-41, 7-20<br />

Q250S 1-43, 7-22<br />

Q260 1-41, 3-135, 7-20<br />

Q260H 1-41, 3-135, 7-20<br />

Q260HH 1-41, 3-135, 7-20<br />

Q260NN 1-43, 7-22<br />

Q260S 1-43, 7-22<br />

Q270 1-41, 3-135, 7-20<br />

Q270H 1-41, 3-135, 7-20<br />

Q270HH 1-41, 3-135, 7-20<br />

Q280 1-41, 3-135, 7-20<br />

Q280H 1-41, 3-135, 7-20<br />

Q280HH 1-41, 3-135, 7-20<br />

Q290 1-41, 3-135, 7-20<br />

I<br />

PRODUCT<br />

INDEX<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog I-23


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

I<br />

PRODUCT<br />

INDEX<br />

Q290H 1-41, 3-135, 7-20<br />

Q290HH 1-41, 3-135, 7-20<br />

Q3015 1-42, 7-21<br />

Q3020 1-42, 7-21<br />

Q3030 1-42, 7-21<br />

Q3030NC 1-42, 7-21<br />

Q3100 1-41, 3-135, 7-20<br />

Q3100H 1-41, 3-135, 7-20<br />

Q3100HH 1-41, 3-135, 7-20<br />

Q315 1-41, 7-20<br />

Q315H 1-41, 7-20<br />

Q315HH 1-41, 7-20<br />

Q320 1-41, 7-20<br />

Q320H 1-41, 7-20<br />

Q320HH 1-41, 7-20<br />

Q325 1-41, 7-20<br />

Q325H 1-41, 7-20<br />

Q325HH 1-41, 7-20<br />

Q330 1-41, 7-20<br />

Q330H 1-41, 7-20<br />

Q330HH 1-41, 7-20<br />

Q335 1-41, 7-20<br />

Q335H 1-41, 7-20<br />

Q335HH 1-41, 7-20<br />

Q340 1-41, 7-20<br />

Q340H 1-41, 7-20<br />

Q340HH 1-41, 7-20<br />

Q345 1-41, 7-20<br />

Q345H 1-41, 7-20<br />

Q345HH 1-41, 7-20<br />

Q350 1-41, 7-20<br />

Q350H 1-41, 7-20<br />

Q350HH 1-41, 7-20<br />

Q360 1-41, 3-135, 7-20<br />

Q360H 1-41, 3-135, 7-20<br />

Q360HH 1-41, 3-135, 7-20<br />

Q370 1-41, 3-135, 7-20<br />

Q370H 1-41, 3-135, 7-20<br />

Q370HH 1-41, 3-135, 7-20<br />

Q380 1-41, 3-135, 7-20<br />

Q380H 1-41, 3-135, 7-20<br />

Q380HH 1-41, 3-135, 7-20<br />

Q390 1-41, 3-135, 7-20<br />

Q390H 1-41, 3-135, 7-20<br />

Q390HH 1-41, 3-135, 7-20<br />

QA115AFC 1-40, 7-19<br />

QA115AFCH 1-40, 7-19<br />

QA115AFCHH 1-40, 7-19<br />

QA115AFCN 1-40, 7-19<br />

Q115DF 1-40, 7-19<br />

QA120AFC 1-40, 7-19<br />

QA120AFCH 1-40, 7-19<br />

QA120AFCN 1-40, 7-19<br />

QC1 3-130<br />

QC4 3-130<br />

QE115 1-40, 7-19<br />

QE115H 1-40, 7-19<br />

QE120 1-40, 7-19<br />

QE120H 1-40, 7-19<br />

QE130 1-40, 7-19<br />

QE130H 1-40, 7-19<br />

QE215 1-40, 7-19<br />

QE215H 1-40, 7-19<br />

QE220 1-40, 7-19<br />

QE220H 1-40, 7-19<br />

QE230 1-40, 7-19<br />

QE230H 1-40, 7-19<br />

QE240 1-40, 7-19<br />

QE240H 1-40, 7-19<br />

QE250 1-40, 7-19<br />

QE250H 1-40, 7-19<br />

QE260 1-40, 7-19<br />

QE260H 1-40, 7-19<br />

QF115A 1-40, 7-19<br />

QF115AH 1-40, 7-19<br />

QF115AHH 1-40, 7-19<br />

QF115AN 1-40, 7-19<br />

QF120A 1-40, 7-19<br />

QF120AH 1-40, 7-19<br />

QF120AHH 1-40, 7-19<br />

QF120AN 1-40, 7-19<br />

QF130A 1-40, 7-19<br />

QF130AH 1-40, 7-19<br />

QF130AHH 1-40, 7-19<br />

QF130AN 1-40, 7-19<br />

QF215A 1-40, 7-19<br />

QF215AH 1-40, 7-19<br />

QF220A 1-40, 7-19<br />

QF220AH 1-40, 7-19<br />

QF230A 1-40, 7-19<br />

QF230AH 1-40, 7-19<br />

QF240A 1-40, 7-19<br />

QF240AH 1-40, 7-19<br />

QF250A 1-40, 7-19<br />

QF250AH 1-40, 7-19<br />

QF260A 1-40, 7-19<br />

QF260AH 1-40, 7-19<br />

QF3 13-19<br />

QG215 1-43, 7-22<br />

QG220 1-43, 7-22<br />

QG320 1-43, 7-22<br />

QN2150 1-45, 7-24<br />

QN2150H 1-45, 7-24<br />

QN2150R 1-45, 7-24<br />

QN2150RH 1-45, 7-24<br />

QN2175 1-45, 7-24<br />

QN2175H 1-45, 7-24<br />

QN2175R 1-45, 7-24<br />

QN2175RH 1-45, 7-24<br />

QN2200 1-45, 7-24<br />

QN2200H 1-45, 7-24<br />

QN2200R 1-45, 7-24<br />

QN2200RH 1-45, 7-24<br />

QPJ3125 1-45, 7-24<br />

QPJ3150 1-45, 7-24<br />

QPJ3200 1-45, 7-24<br />

QR22B100 7-40<br />

QR22B125 7-40<br />

QR22B150 7-40<br />

QR22B175 7-40<br />

QR22B200 7-40<br />

QR22B225 7-40<br />

QR22B250 7-40<br />

QR23B100 3-135, 7-40<br />

QR23B125 3-135, 7-40<br />

QR23B150 3-135, 7-40<br />

QR23B175 3-135, 7-40<br />

QR23B200 3-135, 7-40<br />

QR23B225 3-135, 7-40<br />

QR23B250 7-40<br />

QR2N12 6-13, 7-40<br />

QR2N1F 1-20, 6-9<br />

QR2N1S 1-20, 6-9, 7-40<br />

QR2N3R2 1-20<br />

QR2N3R3 1-20, 6-11, 7-40<br />

QR2N4X 6-12, 7-40<br />

QR2N4X316 6-12, 7-40<br />

QRH22B100 7-40<br />

QRH22B125 7-40<br />

QRH22B150 7-40<br />

QRH22B175 7-40<br />

QRH22B200 7-40<br />

QRH22B225 7-40<br />

QRH22B250 7-40<br />

QRH23B100 3-135, 7-40<br />

QRH23B125 3-135, 7-40<br />

QRH23B150 3-135, 7-40<br />

QRH23B175 3-135, 7-40<br />

QRH23B200 3-135, 7-40<br />

QRH23B225 3-135, 7-40<br />

QRH23B250 7-40<br />

QS2100 3-135, 3-136, 7-25<br />

QS2100H 3-135, 3-136, 7-25<br />

QS2100HH 3-135, 3-136, 7-25<br />

QS2110 7-25<br />

QS2110H 7-25<br />

QS2110HH 7-25<br />

QS2125 3-135, 3-136, 7-25<br />

QS2125H 3-135, 3-136, 7-25<br />

QS2125HH 3-135, 3-136, 7-25<br />

QS2150 3-135, 3-136, 7-25<br />

QS2150H 3-135, 3-136, 7-25<br />

QS2150HH 3-135, 3-136, 7-25<br />

QS2175 3-135, 3-136, 7-25<br />

QS2175H 3-135, 3-136, 7-25<br />

QS2175HH 3-135, 3-136, 7-25<br />

QS2200 3-135, 3-136, 7-25<br />

QS2200H 3-135, 3-136, 7-25<br />

QS2200HH 3-135, 3-136, 7-25<br />

QS2225 3-135, 3-136, 7-25<br />

QS2225H 3-135, 3-136, 7-25<br />

QS2225HH 3-135, 3-136, 7-25<br />

QSA1515SPD 1-50, 7-28<br />

QSA2020SPD 1-50, 7-28<br />

QSH2100 3-135, 3-136, 7-25<br />

QSH2110 7-25<br />

QSH2125 3-135, 3-136, 7-25<br />

QSH2150 3-135, 3-136, 7-25<br />

QSH2175 3-135, 3-136, 7-25<br />

QSH2200 3-135, 3-136, 7-25<br />

QSH2225 3-135, 3-136, 7-25<br />

QSPD2A065P 10-5<br />

QSPD3B065 10-5<br />

QSPD3C065 10-5<br />

QSPD3D065 10-5<br />

R1632L1125 1-18<br />

R1632L1125CU 1-18<br />

R1632L1125W 1-18<br />

R2424L1125 1-18<br />

R2424L1125CU 1-18<br />

R2424L1125W 1-18<br />

R2442L1125 1-18<br />

R2442L1125CU 1-18<br />

R2442L1125CUW 1-18<br />

R2442L1125W 1-18<br />

R3042L1200 1-18<br />

R3042L1200CU 1-18<br />

R3042L1200CUW 1-18<br />

R3042L1200W 1-18<br />

RAG24 1-22<br />

RC(1)23B 11-103<br />

RCW(1)23B 11-103<br />

RD63B160 7-139<br />

RD63B180 7-139, 7-145<br />

RD63B200 7-139, 7-145<br />

RD63F200 7-139<br />

RD63T160 7-139<br />

RD63T180 7-139<br />

RD63T200 7-139<br />

RE0816ML1100J 1-21<br />

RE0816ML1100K 1-21<br />

RE1224ML1125J 1-21<br />

RE1224ML1125K 1-21<br />

REC3100G 15-83<br />

REC4100G 15-83<br />

RFC3250G 15-83<br />

RFC4250G 15-83<br />

RHFF 7-206<br />

RHFFEM 7-206<br />

RHFL 7-206<br />

RHFLEM 7-206<br />

RHOCQVD 7-162<br />

RHOEBO 7-162<br />

RHOFBO 7-162<br />

RHOH 5-13, 7-162, 7-84<br />

RHOH4 7-84<br />

RHOH4C 7-84<br />

RHOH62 7-162<br />

RHOHC 7-84<br />

RHOJBO 7-162<br />

RHOLMBO 7-162<br />

RHONBO 7-162<br />

RHONSD 7-162<br />

RHONSSD 7-162<br />

RHONSVD 7-162<br />

RHONSXD 7-162<br />

RHONVD 7-162<br />

RHOS06 5-13<br />

RHOS20 5-13<br />

RHOSSD 7-162<br />

RHOSVD 5-13, 7-162<br />

RHOSXD 7-162<br />

RHSFA1F 7-206<br />

RHSFA2F 7-206<br />

RHSLA1 7-206<br />

RHSLA1F 7-206<br />

RHSLA2 7-206<br />

RHSLA2F 7-206<br />

RHSMA1 7-207<br />

RHSMA2 7-207<br />

RHSPA1 7-207<br />

RHSPA2 7-207<br />

RHVF12 7-206<br />

RHVF79H 7-206<br />

RHVFBM 7-206<br />

RHVL12 7-206<br />

RHVLBM 7-206<br />

RHVM12 7-207<br />

RHVM12H 7-206, 7-207<br />

RHVM3RH 7-206, 7-207<br />

RHVM4XH 7-206, 7-207<br />

RHVM79H 7-206, 7-207<br />

RHVMBM 7-207<br />

RHVMEMH 7-206, 7-207, 7-84<br />

RHVMS02 7-206, 7-207<br />

RHVMS12 7-206, 7-207<br />

RHVMS16 7-206, 7-207<br />

RHVMS24 7-206, 7-207<br />

RHVP3RH 7-207<br />

RHVP4XH 7-207<br />

RHVP79H 7-207<br />

RHVPBM 7-207<br />

RHVPEMH 7-207, 7-84<br />

RHVPS03 7-207<br />

RHVPS12 7-207<br />

RHVPS24 7-207<br />

RS2641 7-165<br />

RS2642 7-165<br />

RS2643 7-165<br />

RS2644 7-165<br />

RS4755 7-165<br />

RS4756 7-165<br />

RS5773 7-165<br />

RS5774 7-165<br />

RS5783 7-165<br />

RS5784 7-165<br />

RS5785 7-165<br />

RS5786 7-165<br />

RS5787 7-165<br />

RS5788 7-165<br />

RV321G 15-83<br />

RV322G 15-83<br />

RV323G 15-83<br />

RV324G 15-83<br />

RV361G 15-83<br />

RV362G 15-83<br />

RV363G 15-83<br />

RV364G 15-83<br />

RV421G 15-83<br />

RV422G 15-83<br />

RV423G 15-83<br />

RV424G 15-83<br />

RV461G 15-83<br />

RV462G 15-83<br />

RV463G 15-83<br />

RV464G 15-83<br />

RXD63B160 7-139<br />

RXD63B180 7-139, 7-145<br />

RXD63B200 7-139, 7-145<br />

RXD63S200A 7-146<br />

S01ED60 7-113<br />

S01ED62A 7-113<br />

S01ED62AA 7-113<br />

S01ED62AB 7-113<br />

S01ED62B 7-113<br />

S01FD60 7-116<br />

S01JLD6 7-120, 7-124, 7-127<br />

S01JLD62A 7-120, 7-124, 7-127<br />

S01MN6 7-131, 7-135, 7-138<br />

S01MN64A 7-131, 7-135, 7-138<br />

S01QR2 7-41<br />

S01QR2A 7-41<br />

S02ED62A 7-113<br />

S02ED62AA 7-113<br />

S02ED62AB 7-113<br />

S02ED62B 7-113<br />

S02MN6 7-131, 7-135, 7-138<br />

S03ED60 7-113<br />

S03ED62A 7-113<br />

S03ED62AA 7-113<br />

S03ED62AB 7-113<br />

S03ED62B 7-113<br />

S03FD60 7-116<br />

S03JLD6 7-120, 7-124, 7-127<br />

S03JLD62A 7-120, 7-124, 7-127<br />

S03MN6 7-131, 7-135, 7-138<br />

S03MN64A 7-131, 7-135, 7-138<br />

S04ED60 7-113<br />

S04ED64A 7-113<br />

S04ED64AB 7-113<br />

S04ED64B 7-113<br />

S04FD60 7-116<br />

S04JLD6 7-120, 7-124, 7-127<br />

S04MN6 7-131, 7-135, 7-138<br />

S04MN64A 7-131, 7-135, 7-138<br />

S06FD60 7-116<br />

S06MN6 7-131, 7-135, 7-138<br />

S07ED60 7-113<br />

S07ED62A 7-113<br />

S07ED62AA 7-113<br />

S07ED62AB 7-113<br />

S07ED62B 7-113<br />

S07FD60 7-116<br />

S07JLD6 7-120, 7-124, 7-127<br />

S07JLD62A 7-120, 7-124, 7-127<br />

S07MN6 7-131, 7-135, 7-138<br />

S07MN64A 7-131, 7-135, 7-138<br />

S07QR2 7-41<br />

S07QR2A 7-41<br />

S09ED60 7-113<br />

S09ED62A 7-113<br />

S09ED62AA 7-113<br />

S09ED62AB 7-113<br />

S09ED62B 7-113<br />

S09FD60 7-116<br />

S09JLD6 7-120, 7-124, 7-127<br />

S09JLD62A 7-120, 7-124, 7-127<br />

S09MN6 7-131, 7-135, 7-138<br />

S11ED60 7-113<br />

S11ED62A 7-113<br />

S11ED62AA 7-113<br />

S11ED62AB 7-113<br />

S11ED62B 7-113<br />

S11FD60 7-116<br />

S11JLD6 7-120, 7-124, 7-127<br />

S11JLD62A 7-120, 7-124, 7-127<br />

S11MN6 7-131, 7-135, 7-138<br />

S11MN64A 7-131, 7-135, 7-138<br />

S1224B3100 1-15<br />

S1224L3125 1-15<br />

S1224L3200 1-15<br />

S13ED60 7-113<br />

S13ED62A 7-113<br />

S13ED62AA 7-113<br />

S13ED62AB 7-113<br />

S13ED62B 7-113<br />

S13FD60 7-116<br />

S13JLD6 7-120, 7-124, 7-127<br />

S13JLD62A 7-120, 7-124, 7-127<br />

S13MN6 7-131, 7-135, 7-138<br />

S13MN64A 7-131, 7-135, 7-138<br />

S15ED60 7-113<br />

S15ED64A 7-113<br />

S15ED64AB 7-113<br />

S15ED64B 7-113<br />

S15FD60 7-116<br />

S15JLD6 7-120, 7-124, 7-127<br />

S15JLD64A 7-120, 7-124, 7-127<br />

S15MN6 7-131, 7-135, 7-138<br />

S15MN64A 7-131, 7-135, 7-138<br />

S16ED60 7-113<br />

S16ED62A 7-113<br />

S16FD60 7-116<br />

S16JLD6 7-120, 7-124, 7-127<br />

S16JLD62A 7-120, 7-124, 7-127<br />

S16MN6 7-131, 7-135, 7-138<br />

S16MN64A 7-131, 7-135, 7-138<br />

S17ED60 7-113<br />

S17FD60 7-116<br />

S17JLD6 7-120, 7-124, 7-127<br />

S1836L3150 1-15<br />

S18ED60 7-113<br />

S18JLD6 7-120, 7-124, 7-127<br />

S2442B3150 1-15<br />

S2442L3150 1-15<br />

S2442L3200 1-15<br />

S26B 11-38<br />

S3030B3100 1-15<br />

S3042B3100 1-15<br />

S3042B3125 1-15<br />

S3054B3150 1-15<br />

S3054B3200 1-15<br />

S3054L3200 1-15<br />

S32B 11-38<br />

S35815-2 2-25<br />

S38B 11-38<br />

S3VA52PR 13-25<br />

S3VA52T 11-77<br />

S3VA52TD 11-91, 13-25<br />

S4242B3150 1-15<br />

S4242B3225 1-15<br />

S4260B3200 1-15<br />

S4260L3225 1-15<br />

S44B 11-38<br />

S50B 11-38<br />

S5470L3225 1-15<br />

S56B 11-38<br />

S62B 11-38<br />

S68B 11-38<br />

S69623 2-25<br />

S69685-1 2-25<br />

S74B 11-38<br />

SA1E025 6-3, 7-111, 7-154<br />

SBL 11-77<br />

SBLBD 11-91, 13-25<br />

SBMIQR 7-161, 7-41<br />

SC150C 2-8<br />

SC250C 2-8<br />

SC350C 2-8<br />

SCCPB-1-100CF 11-109<br />

I-24<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

SCCPB-1-15CF 11-109<br />

SCCPB-1-20CF 11-109<br />

SCCPB-1-30CF 11-109<br />

SCCPB-1-40CF 11-109<br />

SCCPB-1-50CF 11-109<br />

SCCPB-1-60CF 11-109<br />

SCCPB-1-70CF 11-109<br />

SCCPB-1-90CF 11-109<br />

SCCPB-2-100CF 11-109<br />

SCCPB-2-15CF 11-109<br />

SCCPB-2-20CF 11-109<br />

SCCPB-2-30CF 11-109<br />

SCCPB-2-40CF 11-109<br />

SCCPB-2-50CF 11-109<br />

SCCPB-2-60CF 11-109<br />

SCCPB-2-70CF 11-109<br />

SCCPB-2-90CF 11-109<br />

SCCPB-3-100CF 11-109<br />

SCCPB-3-15CF 11-109<br />

SCCPB-3-20CF 11-109<br />

SCCPB-3-30CF 11-109<br />

SCCPB-3-40CF 11-109<br />

SCCPB-3-50CF 11-109<br />

SCCPB-3-60CF 11-109<br />

SCCPB-3-70CF 11-109<br />

SCCPB-3-90CF 11-109<br />

SCE 11-77<br />

SCED 11-91<br />

SCF 11-77<br />

SCFD 11-91<br />

SCJ 11-77<br />

SCJD 11-91<br />

SCJD6A200LI 7-119<br />

SCJD6A200LIG 7-119<br />

SCJD6A200LSI 7-119<br />

SCJD6A200LSIG 7-119<br />

SCJD6A300LI 7-119<br />

SCJD6A300LIG 7-119<br />

SCJD6A300LSI 7-119<br />

SCJD6A300LSIG 7-119<br />

SCJD6A400LI 7-119<br />

SCJD6A400LIG 7-119<br />

SCJD6A400LSI 7-119<br />

SCJD6A400LSIG 7-119<br />

SCJD6B200LI 7-119<br />

SCJD6B200LIG 7-119<br />

SCJD6B200LSI 7-119<br />

SCJD6B200LSIG 7-119<br />

SCJD6B300LI 7-119<br />

SCJD6B300LIG 7-119<br />

SCJD6B300LSI 7-119<br />

SCJD6B300LSIG 7-119<br />

SCJD6B400LI 7-119<br />

SCJD6B400LIG 7-119<br />

SCJD6B400LSI 7-119<br />

SCJD6B400LSIG 7-119<br />

SCL 11-77<br />

SCLD 11-91<br />

SCLD6A300LI 7-123<br />

SCLD6A300LIG 7-123<br />

SCLD6A300LSI 7-123<br />

SCLD6A300LSIG 7-123<br />

SCLD6A400LI 7-123<br />

SCLD6A400LIG 7-123<br />

SCLD6A400LSI 7-123<br />

SCLD6A400LSIG 7-123<br />

SCLD6A500LI 7-123<br />

SCLD6A500LIG 7-123<br />

SCLD6A500LSI 7-123<br />

SCLD6A500LSIG 7-123<br />

SCLD6A600LI 7-123<br />

SCLD6A600LIG 7-123<br />

SCLD6A600LSI 7-123<br />

SCLD6A600LSIG 7-123<br />

SCLD6B300LI 7-123<br />

SCLD6B300LIG 7-123<br />

SCLD6B300LSI 7-123<br />

SCLD6B300LSIG 7-123<br />

SCLD6B400LI 7-123<br />

SCLD6B400LIG 7-123<br />

SCLD6B400LSI 7-123<br />

SCLD6B400LSIG 7-123<br />

SCLD6B500LI 7-123<br />

SCLD6B500LIG 7-123<br />

SCLD6B500LSI 7-123<br />

SCLD6B500LSIG 7-123<br />

SCLD6B600LI 7-123<br />

SCLD6B600LIG 7-123<br />

SCLD6B600LSI 7-123<br />

SCLD6B600LSIG 7-123<br />

SCMD6A600LI 7-130<br />

SCMD6A600LIG 7-130<br />

SCMD6A600LIGH 7-130<br />

SCMD6A600LIH 7-130<br />

SCMD6A600LSI 7-130<br />

SCMD6A600LSIG 7-130<br />

SCMD6A600LSIGH 7-130<br />

SCMD6A600LSIH 7-130<br />

SCMD6A700LI 7-130<br />

SCMD6A700LIG 7-130<br />

SCMD6A700LIGH 7-130<br />

SCMD6A700LIH 7-130<br />

SCMD6A700LSI 7-130<br />

SCMD6A700LSIG 7-130<br />

SCMD6A700LSIGH 7-130<br />

SCMD6A700LSIH 7-130<br />

SCMD6A800LI 7-130<br />

SCMD6A800LIG 7-130<br />

SCMD6A800LIGH 7-130<br />

SCMD6A800LIH 7-130<br />

SCMD6A800LSI 7-130<br />

SCMD6A800LSIG 7-130<br />

SCMD6A800LSIGH 7-130<br />

SCMD6A800LSIH 7-130<br />

SCMD6B600LI 7-130<br />

SCMD6B600LIG 7-130<br />

SCMD6B600LIGH 7-130<br />

SCMD6B600LIH 7-130<br />

SCMD6B600LSI 7-130<br />

SCMD6B600LSIG 7-130<br />

SCMD6B600LSIGH 7-130<br />

SCMD6B600LSIH 7-130<br />

SCMD6B700LI 7-130<br />

SCMD6B700LIG 7-130<br />

SCMD6B700LIGH 7-130<br />

SCMD6B700LIH 7-130<br />

SCMD6B700LSI 7-130<br />

SCMD6B700LSIG 7-130<br />

SCMD6B700LSIGH 7-130<br />

SCMD6B700LSIH 7-130<br />

SCMD6B800LI 7-130<br />

SCMD6B800LIG 7-130<br />

SCMD6B800LIGH 7-130<br />

SCMD6B800LIH 7-130<br />

SCMD6B800LSI 7-130<br />

SCMD6B800LSIG 7-130<br />

SCMD6B800LSIGH 7-130<br />

SCMD6B800LSIH 7-130<br />

SCND6A100LI 7-134<br />

SCND6A100LIG 7-134<br />

SCND6A100LIGH 7-134<br />

SCND6A100LIH 7-134<br />

SCND6A100LSI 7-134<br />

SCND6A100LSIG 7-134<br />

SCND6A100LSIGH 7-134<br />

SCND6A100LSIH 7-134<br />

SCND6A120LI 7-134<br />

SCND6A120LIG 7-134<br />

SCND6A120LIGH 7-134<br />

SCND6A120LIH 7-134<br />

SCND6A120LSI 7-134<br />

SCND6A120LSIG 7-134<br />

SCND6A120LSIGH 7-134<br />

SCND6A120LSIH 7-134<br />

SCND6A800LI 7-134<br />

SCND6A800LIG 7-134<br />

SCND6A800LIGH 7-134<br />

SCND6A800LIH 7-134<br />

SCND6A800LSI 7-134<br />

SCND6A800LSIG 7-134<br />

SCND6A800LSIGH 7-134<br />

SCND6A800LSIH 7-134<br />

SCND6B100LI 7-134<br />

SCND6B100LIG 7-134<br />

SCND6B100LIGH 7-134<br />

SCND6B100LIH 7-134<br />

SCND6B100LSI 7-134<br />

SCND6B100LSIG 7-134<br />

SCND6B100LSIGH 7-134<br />

SCND6B100LSIH 7-134<br />

SCND6B120LI 7-134<br />

SCND6B120LIG 7-134<br />

SCND6B120LIGH 7-134<br />

SCND6B120LIH 7-134<br />

SCND6B120LSI 7-134<br />

SCND6B120LSIG 7-134<br />

SCND6B120LSIGH 7-134<br />

SCND6B120LSIH 7-134<br />

SCND6B800LI 7-134<br />

SCND6B800LIG 7-134<br />

SCND6B800LIGH 7-134<br />

SCND6B800LIH 7-134<br />

SCND6B800LSI 7-134<br />

SCND6B800LSIG 7-134<br />

SCND6B800LSIGH 7-134<br />

SCND6B800LSIH 7-134<br />

SCT1236 13-22<br />

SCT432 13-22<br />

SCT436 13-22<br />

SCT632 13-22<br />

SCT636 13-22<br />

SCT836 13-22<br />

SDG 11-77<br />

SDGD 11-91, 13-25<br />

SE6 11-77<br />

SE6D 11-91<br />

SEAFB 7-210<br />

SEAFM 7-210<br />

SEAFN 7-210<br />

SEAFR 7-210<br />

SEAFY 7-210<br />

SEALB 7-211<br />

SEALM 7-211<br />

SEALN 7-211<br />

SEALR 7-211<br />

SEALY 7-211<br />

SEAMB 7-211<br />

SEAMM 7-211<br />

SEAMN 7-211<br />

SEAMR 7-211<br />

SEAMY 7-211<br />

SEBD 13-25<br />

SEBKP1P2P3V1 11-11, 11-23, 11-38,<br />

11-49<br />

SEBKP2V1 11-38<br />

SEBKP2V2 11-38<br />

SEBKP2V3 11-38, 11-49<br />

SEBKP2V4 11-38<br />

SEBKP2V5 11-38<br />

SEBKP2V6 11-38<br />

SEBKP3V1 11-49<br />

SEBKRP1V1 11-11, 11-23<br />

SEBKRP1V2 11-11, 11-23<br />

SEBKRP1V3 11-11, 11-23<br />

SEBKRP1V4 11-11, 11-23<br />

SEBKRP1V5 11-11, 11-23<br />

SEBP4V1 11-77, 11-91<br />

SEBP4V2 11-77, 11-91<br />

SEBP4V3 11-77, 11-91<br />

SEBP5V1 11-91<br />

SEBP5V2 11-91<br />

SEBP5V3 11-91<br />

SEBP5V4 11-91<br />

SF6 11-77<br />

SF6D 11-91<br />

SFG 11-77<br />

SFGD 11-91, 13-25<br />

SGB2 11-77<br />

SGB2D 11-91, 13-25<br />

SHJD6A200LI 7-119<br />

SHJD6A200LIG 7-119<br />

SHJD6A200LIGH 7-119<br />

SHJD6A200LIH 7-119<br />

SHJD6A200LSI 7-119<br />

SHJD6A200LSIG 7-119<br />

SHJD6A200LSIGH 7-119<br />

SHJD6A200LSIH 7-119<br />

SHJD6A300LI 7-119<br />

SHJD6A300LIG 7-119<br />

SHJD6A300LIGH 7-119<br />

SHJD6A300LIH 7-119<br />

SHJD6A300LSI 7-119<br />

SHJD6A300LSIG 7-119<br />

SHJD6A300LSIGH 7-119<br />

SHJD6A300LSIH 7-119<br />

SHJD6A400LI 7-119<br />

SHJD6A400LIG 7-119<br />

SHJD6A400LIGH 7-119<br />

SHJD6A400LIH 7-119<br />

SHJD6A400LSI 7-119<br />

SHJD6A400LSIG 7-119<br />

SHJD6A400LSIGH 7-119<br />

SHJD6A400LSIH 7-119<br />

SHJD6B200LI 7-119<br />

SHJD6B200LIG 7-119<br />

SHJD6B200LIGH 7-119<br />

SHJD6B200LIH 7-119<br />

SHJD6B200LSI 7-119<br />

SHJD6B200LSIG 7-119<br />

SHJD6B200LSIGH 7-119<br />

SHJD6B200LSIH 7-119<br />

SHJD6B300LI 7-119<br />

SHJD6B300LIG 7-119<br />

SHJD6B300LIGH 7-119<br />

SHJD6B300LIH 7-119<br />

SHJD6B300LSI 7-119<br />

SHJD6B300LSIG 7-119<br />

SHJD6B300LSIGH 7-119<br />

SHJD6B300LSIH 7-119<br />

SHJD6B400LI 7-119<br />

SHJD6B400LIG 7-119<br />

SHJD6B400LIGH 7-119<br />

SHJD6B400LIH 7-119<br />

SHJD6B400LSI 7-119<br />

SHJD6B400LSIG 7-119<br />

SHJD6B400LSIGH 7-119<br />

SHJD6B400LSIH 7-119<br />

SHLD6A300LI 7-123<br />

SHLD6A300LIG 7-123<br />

SHLD6A300LSI 7-123<br />

SHLD6A300LSIG 7-123<br />

SHLD6A400LI 7-123<br />

SHLD6A400LIG 7-123<br />

SHLD6A400LSI 7-123<br />

SHLD6A400LSIG 7-123<br />

SHLD6A500LI 7-123<br />

SHLD6A500LIG 7-123<br />

SHLD6A500LSI 7-123<br />

SHLD6A500LSIG 7-123<br />

SHLD6A600LI 7-123<br />

SHLD6A600LIG 7-123<br />

SHLD6A600LSI 7-123<br />

SHLD6A600LSIG 7-123<br />

SHLD6B300LI 7-123<br />

SHLD6B300LIG 7-123<br />

SHLD6B300LSI 7-123<br />

SHLD6B300LSIG 7-123<br />

SHLD6B400LI 7-123<br />

SHLD6B400LIG 7-123<br />

SHLD6B400LSI 7-123<br />

SHLD6B400LSIG 7-123<br />

SHLD6B500LI 7-123<br />

SHLD6B500LIG 7-123<br />

SHLD6B500LSI 7-123<br />

SHLD6B500LSIG 7-123<br />

SHLD6B600LI 7-123<br />

SHLD6B600LIG 7-123<br />

SHLD6B600LSI 7-123<br />

SHLD6B600LSIG 7-123<br />

SHMD6A600LI 7-130<br />

SHMD6A600LIG 7-130<br />

SHMD6A600LIGH 7-130<br />

SHMD6A600LIH 7-130<br />

SHMD6A600LSI 7-130<br />

SHMD6A600LSIG 7-130<br />

SHMD6A600LSIGH 7-130<br />

SHMD6A600LSIH 7-130<br />

SHMD6A700LI 7-130<br />

SHMD6A700LIG 7-130<br />

SHMD6A700LIGH 7-130<br />

SHMD6A700LIH 7-130<br />

SHMD6A700LSI 7-130<br />

SHMD6A700LSIG 7-130<br />

SHMD6A700LSIGH 7-130<br />

SHMD6A700LSIH 7-130<br />

SHMD6A800LI 7-130<br />

SHMD6A800LIG 7-130<br />

SHMD6A800LIGH 7-130<br />

SHMD6A800LIH 7-130<br />

SHMD6A800LSI 7-130<br />

SHMD6A800LSIG 7-130<br />

SHMD6A800LSIGH 7-130<br />

SHMD6A800LSIH 7-130<br />

SHMD6B600LI 7-130<br />

SHMD6B600LIG 7-130<br />

SHMD6B600LIGH 7-130<br />

SHMD6B600LIH 7-130<br />

SHMD6B600LSI 7-130<br />

SHMD6B600LSIG 7-130<br />

SHMD6B600LSIGH 7-130<br />

SHMD6B600LSIH 7-130<br />

SHMD6B700LI 7-130<br />

SHMD6B700LIG 7-130<br />

SHMD6B700LIGH 7-130<br />

SHMD6B700LIH 7-130<br />

SHMD6B700LSI 7-130<br />

SHMD6B700LSIG 7-130<br />

SHMD6B700LSIGH 7-130<br />

SHMD6B700LSIH 7-130<br />

SHMD6B800LI 7-130<br />

SHMD6B800LIG 7-130<br />

SHMD6B800LIGH 7-130<br />

SHMD6B800LIH 7-130<br />

SHMD6B800LSI 7-130<br />

SHMD6B800LSIG 7-130<br />

SHMD6B800LSIGH 7-130<br />

SHMD6B800LSIH 7-130<br />

SHND6A100LI 7-134<br />

SHND6A100LIG 7-134<br />

SHND6A100LIGH 7-134<br />

SHND6A100LIH 7-134<br />

SHND6A100LSI 7-134<br />

SHND6A100LSIG 7-134<br />

SHND6A100LSIGH 7-134<br />

SHND6A100LSIH 7-134<br />

SHND6A120LI 7-134<br />

SHND6A120LIG 7-134<br />

SHND6A120LIGH 7-134<br />

SHND6A120LIH 7-134<br />

SHND6A120LSI 7-134<br />

SHND6A120LSIG 7-134<br />

SHND6A120LSIGH 7-134<br />

SHND6A120LSIH 7-134<br />

SHND6A800LI 7-134<br />

SHND6A800LIG 7-134<br />

SHND6A800LIGH 7-134<br />

SHND6A800LIH 7-134<br />

SHND6A800LSI 7-134<br />

SHND6A800LSIG 7-134<br />

SHND6A800LSIGH 7-134<br />

SHND6A800LSIH 7-134<br />

SHND6B100LI 7-134<br />

SHND6B100LIG 7-134<br />

SHND6B100LIGH 7-134<br />

SHND6B100LIH 7-134<br />

SHND6B100LSI 7-134<br />

SHND6B100LSIG 7-134<br />

SHND6B100LSIGH 7-134<br />

SHND6B100LSIH 7-134<br />

SHND6B120LI 7-134<br />

SHND6B120LIG 7-134<br />

SHND6B120LIGH 7-134<br />

SHND6B120LIH 7-134<br />

SHND6B120LSI 7-134<br />

SHND6B120LSIG 7-134<br />

SHND6B120LSIGH 7-134<br />

SHND6B120LSIH 7-134<br />

SHND6B800LI 7-134<br />

SHND6B800LIG 7-134<br />

SHND6B800LIGH 7-134<br />

SHND6B800LIH 7-134<br />

SHND6B800LSI 7-134<br />

SHND6B800LSIG 7-134<br />

SHND6B800LSIGH 7-134<br />

SHND6B800LSIH 7-134<br />

SHPD6A140LI 7-137<br />

SHPD6A140LIG 7-137<br />

SHPD6A140LSI 7-137<br />

SHPD6A140LSIG 7-137<br />

SHPD6A160LI 7-137<br />

SHPD6A160LIG 7-137<br />

SHPD6A160LSI 7-137<br />

SHPD6A160LSIG 7-137<br />

SHPD6B140LI 7-137<br />

SHPD6B140LIG 7-137<br />

SHPD6B140LSI 7-137<br />

SHPD6B140LSIG 7-137<br />

SHPD6B160LI 7-137<br />

SHPD6B160LIG 7-137<br />

SHPD6B160LSI 7-137<br />

SHPD6B160LSIG 7-137<br />

SIRIUS ACT 3SU 17-297, 17-298<br />

SJ1 11-77<br />

SJ1D 11-91<br />

SJ2D 11-91<br />

SJD6A200LI 7-119<br />

SJD6A200LIG 7-119<br />

SJD6A200LIGH 7-119<br />

SJD6A200LIH 7-119<br />

SJD6A200LSI 7-119<br />

SJD6A200LSIG 7-119<br />

SJD6A200LSIGH 7-119<br />

SJD6A200LSIH 7-119<br />

SJD6A300LI 7-119<br />

SJD6A300LIG 7-119<br />

SJD6A300LIGH 7-119<br />

SJD6A300LIH 7-119<br />

SJD6A300LSI 7-119<br />

SJD6A300LSIG 7-119<br />

SJD6A300LSIGH 7-119<br />

I<br />

PRODUCT<br />

INDEX<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog I-25


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

I<br />

PRODUCT<br />

INDEX<br />

SJD6A300LSIH 7-119<br />

SJD6A400LI 7-119<br />

SJD6A400LIG 7-119<br />

SJD6A400LIGH 7-119<br />

SJD6A400LIH 7-119<br />

SJD6A400LSI 7-119<br />

SJD6A400LSIG 7-119<br />

SJD6A400LSIGH 7-119<br />

SJD6A400LSIH 7-119<br />

SJD6B200LI 7-119<br />

SJD6B200LIG 7-119<br />

SJD6B200LIGH 7-119<br />

SJD6B200LIH 7-119<br />

SJD6B200LSI 7-119<br />

SJD6B200LSIG 7-119<br />

SJD6B200LSIGH 7-119<br />

SJD6B200LSIH 7-119<br />

SJD6B300LI 7-119<br />

SJD6B300LIG 7-119<br />

SJD6B300LIGH 7-119<br />

SJD6B300LIH 7-119<br />

SJD6B300LSI 7-119<br />

SJD6B300LSIG 7-119<br />

SJD6B300LSIGH 7-119<br />

SJD6B300LSIH 7-119<br />

SJD6B400LI 7-119<br />

SJD6B400LIG 7-119<br />

SJD6B400LIGH 7-119<br />

SJD6B400LIH 7-119<br />

SJD6B400LSI 7-119<br />

SJD6B400LSIG 7-119<br />

SJD6B400LSIGH 7-119<br />

SJD6B400LSIH 7-119<br />

SJG 11-77<br />

SJG1D 11-91, 13-25<br />

SJG2D 11-91, 13-25<br />

SL0420 4-22<br />

SL6 11-77<br />

SL6D 11-91<br />

SLD6A300LI 7-123<br />

SLD6A300LIG 7-123<br />

SLD6A300LSI 7-123<br />

SLD6A300LSIG 7-123<br />

SLD6A400LI 7-123<br />

SLD6A400LIG 7-123<br />

SLD6A400LSI 7-123<br />

SLD6A400LSIG 7-123<br />

SLD6A500LI 7-123<br />

SLD6A500LIG 7-123<br />

SLD6A500LSI 7-123<br />

SLD6A500LSIG 7-123<br />

SLD6A600LI 7-123<br />

SLD6A600LIG 7-123<br />

SLD6A600LSI 7-123<br />

SLD6A600LSIG 7-123<br />

SLD6B300LI 7-123<br />

SLD6B300LIG 7-123<br />

SLD6B300LSI 7-123<br />

SLD6B300LSIG 7-123<br />

SLD6B400LI 7-123<br />

SLD6B400LIG 7-123<br />

SLD6B400LSI 7-123<br />

SLD6B400LSIG 7-123<br />

SLD6B500LI 7-123<br />

SLD6B500LIG 7-123<br />

SLD6B500LSI 7-123<br />

SLD6B500LSIG 7-123<br />

SLD6B600LI 7-123<br />

SLD6B600LIG 7-123<br />

SLD6B600LSI 7-123<br />

SLD6B600LSIG 7-123<br />

SLEC32***0ED2 15-46<br />

SLEC32***0GED2 15-46<br />

SLEC32***0IGED2 15-46<br />

SLEC34***0ED4 15-46<br />

SLEC34***0GED4 15-46<br />

SLEC34***0IGED4 15-46<br />

SLEC36***0ED6 15-46<br />

SLEC36***0GED6 15-46<br />

SLEC36***0IGED6 15-46<br />

SLEC42***0ED2 15-46<br />

SLEC42***0GED2 15-46<br />

SLEC42***0IGED2 15-46<br />

SLEC44***0ED4 15-46<br />

SLEC44***0GED4 15-46<br />

SLEC44***0IGED4 15-46<br />

SLEC46***0ED6 15-46<br />

SLEC46***0GED6 15-46<br />

SLEC46***0IGED6 15-46<br />

SLEC52***0ED2 15-46<br />

SLEC52***0GED2 15-46<br />

SLEC52***0IGED2 15-46<br />

SLEC54***0ED4 15-46<br />

SLEC54***0GED4 15-46<br />

SLEC54***0IGED4 15-46<br />

SLEC56***0ED6 15-46<br />

SLEC56***0GED6 15-46<br />

SLEC56***0IGED6 15-46<br />

SLEL36***0CED6 15-47<br />

SLEL36***0GCED6 15-47<br />

SLEL36***0IGCED6 15-47<br />

SLEL46***0CED6 15-47<br />

SLEL46***0GCED6 15-47<br />

SLEL46***0IGCED6 15-47<br />

SLEL56***0CED6 15-47<br />

SLEL56***0GCED6 15-47<br />

SLEL56***0IGCED6 15-47<br />

SLFC36***0FXD6 15-46<br />

SLFC36***0GFXD6 15-46<br />

SLFC36***0IGFXD6 15-46<br />

SLFC362500FXD6 15-46<br />

SLFC362500GFXD6 15-46<br />

SLFC362500IGFXD6 15-46<br />

SLFC46***0FXD6 15-46<br />

SLFC46***0GFXD6 15-46<br />

SLFC46***0IGFXD6 15-46<br />

SLFC462500FXD6 15-46<br />

SLFC462500GFXD6 15-46<br />

SLFC462500IGFXD6 15-46<br />

SLFC56***0FXD6 15-46<br />

SLFC56***0GFXD6 15-46<br />

SLFC56***0IGFXD6 15-46<br />

SLFL36***0CFD6 15-47<br />

SLFL36***0GCFD6 15-47<br />

SLFL36***0IGCFD6 15-47<br />

SLFL362500CFD6 15-47<br />

SLFL362500CGFD6 15-47<br />

SLFL362500ICGFD6 15-47<br />

SLFL46***0CFD6 15-47<br />

SLFL46***0GCFD6 15-47<br />

SLFL46***0IGCFD6 15-47<br />

SLFL462500CFD6 15-47<br />

SLFL462500GCFD6 15-47<br />

SLFL462500IGCFD6 15-47<br />

SLFL56***0CFD6 15-47<br />

SLFL56***0GCFD6 15-47<br />

SLFL56***0IGCFD6 15-47<br />

SLG 11-77<br />

SLGD 11-91, 13-25<br />

SLJ2600 15-52<br />

SLJ6600 15-52<br />

SLJC36***0GJXD6 15-46<br />

SLJC36***0IGJXD6 15-46<br />

SLJC36***0JXD6 15-46<br />

SLJC46***0GJXD6 15-46<br />

SLJC46***0IGJXD6 15-46<br />

SLJC46***0JXD6 15-46<br />

SLJL36***0CGJD6 15-47<br />

SLJL36***0CJD6 15-47<br />

SLJL36***0ICGJD6 15-47<br />

SLJL46***0CJD6 15-47<br />

SLJL46***0GCJD6 15-47<br />

SLJL46***0IGCJD6 15-47<br />

SLJL562000CJD6 15-47<br />

SLJL562000GCJD6 15-47<br />

SLJL562000IGCJD6 15-47<br />

SLJLS56***0CJD6 15-47<br />

SLJLS56***0GCJD6 15-47<br />

SLJLS56***0IGCJD6 15-47<br />

SLLCS36***0GLXD6 15-46<br />

SLLCS36***0IGLXD6 15-46<br />

SLLCS36***0LXD6 15-46<br />

SLLCS46***0GLXD6 15-46<br />

SLLCS46***0IGLXD6 15-46<br />

SLLCS46***0LXD6 15-46<br />

SLLLS36***0CLD6 15-47<br />

SLLLS36***0CMD6 15-47<br />

SLLLS36***0GCLD6 15-47<br />

SLLLS36***0GCMD6 15-47<br />

SLLLS36***0IGCLD6 15-47<br />

SLLLS36***0IGCMD6 15-47<br />

SLLLS46***0CLD6 15-47<br />

SLLLS46***0CMD6 15-47<br />

SLLLS46***0GCLD6 15-47<br />

SLLLS46***0GCMD6 15-47<br />

SLLLS46***0IGCLD6 15-47<br />

SLLLS46***0IGCMD6 15-47<br />

SLM1D 11-91, 13-25<br />

SLMCS36***0GMXD6 15-46<br />

SLMCS36***0IGMXD6 15-46<br />

SLMCS36***0MXD6 15-46<br />

SLMCS46***0GMXD6 15-46<br />

SLMCS46***0IGMXD6 15-46<br />

SLMCS46***0MXD6 15-46<br />

SLPGR3140G 15-52<br />

SLR2030 15-52<br />

SLR2060 15-52<br />

SLR2100 15-52<br />

SLR2200 15-52<br />

SLR2400 15-52<br />

SLR2600 15-52<br />

SLR6030 15-52<br />

SLR6060 15-52<br />

SLR6100 15-52<br />

SLR6200 15-52<br />

SLR6400 15-52<br />

SLR6600 15-52<br />

SLT2100 15-52<br />

SLT2200 15-52<br />

SLT2400 15-52<br />

SLT2600 15-52<br />

SLT6100 15-52<br />

SLT6200 15-52<br />

SLT6400 15-52<br />

SLT6600 15-52<br />

SLVB*3210 15-52<br />

SLVB*3210G 15-52<br />

SLVB*3210IG 15-52<br />

SLVB*3220 15-52<br />

SLVB*3220G 15-52<br />

SLVB*3220IG 15-52<br />

SLVB*3230 15-52<br />

SLVB*3230G 15-52<br />

SLVB*3230IG 15-52<br />

SLVB*3240 15-52<br />

SLVB*3240G 15-52<br />

SLVB*3240IG 15-52<br />

SLVB*3250 15-52<br />

SLVB*3250G 15-52<br />

SLVB*3250IG 15-52<br />

SLVB*3260 15-52<br />

SLVB*3260G 15-52<br />

SLVB*3260IG 15-52<br />

SLVB*3610 15-52<br />

SLVB*3610G 15-52<br />

SLVB*3610IG 15-52<br />

SLVB*3620 15-52<br />

SLVB*3620G 15-52<br />

SLVB*3620IG 15-52<br />

SLVB*3630 15-52<br />

SLVB*3630G 15-52<br />

SLVB*3630IG 15-52<br />

SLVB*3640 15-52<br />

SLVB*3640G 15-52<br />

SLVB*3640IG 15-52<br />

SLVB*3650 15-52<br />

SLVB*3650G 15-52<br />

SLVB*3650IG 15-52<br />

SLVB*3660 15-52<br />

SLVB*3660G 15-52<br />

SLVB*3660IG 15-52<br />

SLVB*4210 15-52<br />

SLVB*4210G 15-52<br />

SLVB*4210IG 15-52<br />

SLVB*4220 15-52<br />

SLVB*4220G 15-52<br />

SLVB*4220IG 15-52<br />

SLVB*4230 15-52<br />

SLVB*4230G 15-52<br />

SLVB*4230IG 15-52<br />

SLVB*4240 15-52<br />

SLVB*4240G 15-52<br />

SLVB*4240IG 15-52<br />

SLVB*4250 15-52<br />

SLVB*4250G 15-52<br />

SLVB*4250IG 15-52<br />

SLVB*4260 15-52<br />

SLVB*4260G 15-52<br />

SLVB*4260IG 15-52<br />

SLVB*4610 15-52<br />

SLVB*4610G 15-52<br />

SLVB*4610IG 15-52<br />

SLVB*4620 15-52<br />

SLVB*4620G 15-52<br />

SLVB*4620IG 15-52<br />

SLVB*4630 15-52<br />

SLVB*4630G 15-52<br />

SLVB*4630IG 15-52<br />

SLVB*4640 15-52<br />

SLVB*4640G 15-52<br />

SLVB*4640IG 15-52<br />

SLVB*4650 15-52<br />

SLVB*4650G 15-52<br />

SLVB*4650IG 15-52<br />

SLVB*4660 15-52<br />

SLVB*4660G 15-52<br />

SLVB*4660IG 15-52<br />

SLVB*5210 15-52<br />

SLVB*5210G 15-52<br />

SLVB*5210IG 15-52<br />

SLVB*5220 15-52<br />

SLVB*5220G 15-52<br />

SLVB*5220IG 15-52<br />

SLVB*5230 15-52<br />

SLVB*5230G 15-52<br />

SLVB*5230IG 15-52<br />

SLVB*5240 15-52<br />

SLVB*5240G 15-52<br />

SLVB*5240IG 15-52<br />

SLVB*5250 15-52<br />

SLVB*5250G 15-52<br />

SLVB*5250IG 15-52<br />

SLVB*5610 15-52<br />

SLVB*5610G 15-52<br />

SLVB*5610IG 15-52<br />

SLVB*5620 15-52<br />

SLVB*5620G 15-52<br />

SLVB*5620IG 15-52<br />

SLVB*5630 15-52<br />

SLVB*5630G 15-52<br />

SLVB*5630IG 15-52<br />

SLVB*5640 15-52<br />

SLVB*5640G 15-52<br />

SLVB*5640IG 15-52<br />

SLVB*5650 15-52<br />

SLVB*5650G 15-52<br />

SLVB*5650IG 15-52<br />

SMB6R 1-48, 7-158<br />

SMBKED1 11-15<br />

SMBKED3 11-15<br />

SMBKFD1 11-15<br />

SMBKFD3 11-15<br />

SMBKJD1 11-15<br />

SMBKJD3 11-15<br />

SMBKLD1 11-15<br />

SMBKLD3 11-15<br />

SMD6A600LI 7-130<br />

SMD6A600LIG 7-130<br />

SMD6A600LIGH 7-130<br />

SMD6A600LIH 7-130<br />

SMD6A600LSI 7-130<br />

SMD6A600LSIG 7-130<br />

SMD6A600LSIGH 7-130<br />

SMD6A600LSIH 7-130<br />

SMD6A700LI 7-130<br />

SMD6A700LIG 7-130<br />

SMD6A700LIGH 7-130<br />

SMD6A700LIH 7-130<br />

SMD6A700LSI 7-130<br />

SMD6A700LSIG 7-130<br />

SMD6A700LSIGH 7-130<br />

SMD6A700LSIH 7-130<br />

SMD6A800LI 7-130<br />

SMD6A800LIG 7-130<br />

SMD6A800LIGH 7-130<br />

SMD6A800LIH 7-130<br />

SMD6A800LSI 7-130<br />

SMD6A800LSIG 7-130<br />

SMD6A800LSIGH 7-130<br />

SMD6A800LSIH 7-130<br />

SMD6B600LI 7-130<br />

SMD6B600LIG 7-130<br />

SMD6B600LIGH 7-130<br />

SMD6B600LIH 7-130<br />

SMD6B600LSI 7-130<br />

SMD6B600LSIG 7-130<br />

SMD6B600LSIGH 7-130<br />

SMD6B600LSIH 7-130<br />

SMD6B700LI 7-130<br />

SMD6B700LIG 7-130<br />

SMD6B700LIGH 7-130<br />

SMD6B700LIH 7-130<br />

SMD6B700LSI 7-130<br />

SMD6B700LSIG 7-130<br />

SMD6B700LSIGH 7-130<br />

SMD6B700LSIH 7-130<br />

SMD6B800LI 7-130<br />

SMD6B800LIG 7-130<br />

SMD6B800LIGH 7-130<br />

SMD6B800LIH 7-130<br />

SMD6B800LSI 7-130<br />

SMD6B800LSIG 7-130<br />

SMD6B800LSIGH 7-130<br />

SMD6B800LSIH 7-130<br />

SMF Manual Control 17-6, 17-7<br />

SMLKA1 11-15<br />

SMLKA3 11-15<br />

SMMBQMK 13-26<br />

SMMCEMK 13-26<br />

SMMEDMK 13-26<br />

SMMFDMK 13-26<br />

SMMHEMK 13-26<br />

SMMNGMK 13-26<br />

SMMQRMK 13-26<br />

SMMTFMK 13-26<br />

SMND 11-91, 13-25<br />

SMU-CT-011 9-25<br />

SMU-CT-021 9-25<br />

SMU-CT-025 9-25<br />

SMU-CT-02R 9-25<br />

SMU-CT-031 9-25<br />

SMU-CT-041 9-25<br />

SMU-CT-061 9-25<br />

SMU-CT-081 9-25<br />

SMU-CT-123 9-25<br />

SN1212L1125 1-10<br />

SN1224B1100 1-9<br />

SN1224L1125 1-10<br />

SN1224L1200 1-10<br />

SN1632B1100 1-9<br />

SN1632B1125 1-9<br />

SN1632B1150 1-9<br />

SN1632B1200 1-9<br />

SN1632L1125 1-10<br />

SN1632L1150 1-10<br />

SN2020B1100 1-9<br />

SN2020L1125 1-10<br />

SN2040B1100 1-9<br />

SN2040B1150 1-9<br />

SN2040B1200 1-9<br />

SN2040C1200 1-11<br />

SN2040L1125 1-10<br />

SN2040L1150 1-10<br />

SN2040L1200 1-10<br />

SN205CX 2-8<br />

SN211AR 2-8<br />

SN2424B1125 1-9<br />

SN2424C1125 1-11<br />

SN2424L1125 1-10<br />

SN2448B1100 1-9<br />

SN2448B1150 1-9<br />

SN2448B1200 1-9<br />

SN2448L1125 1-10<br />

SN2448L1150 1-10<br />

SN2448L1200 1-10<br />

SN251CR 2-8<br />

SN3030B1100 1-9<br />

SN3030B1125 1-9<br />

SN3030B1150 1-9<br />

SN3030L1200 1-10<br />

SN3048B1100 1-9<br />

SN3048B1125 1-9<br />

SN3048B1150 1-9<br />

SN3048B1200 1-9<br />

SN3048B1200S06 1-11<br />

SN3048C1200 1-11<br />

SN3048L1125 1-10<br />

SN3048L1200 1-10<br />

SN3048L1200L50 1-11<br />

SN305CX 2-8<br />

SN311AR 2-8<br />

SN351CR 2-8<br />

SN4040B1200 1-9<br />

SN4040C1200 1-11<br />

SN4040L1125 1-10<br />

SN4040L1200 1-10<br />

SN4060B1200 1-9<br />

SN4060B1200S06 1-11<br />

SN4060L1225 1-10<br />

SN411AR 2-8<br />

SN4264B1200 1-9<br />

SN4264B1225 1-9<br />

SN4264L1225 1-10<br />

SN451CR 2-8<br />

SN5482B1200 1-9<br />

SN5482B1225 1-9<br />

SN5482L1225 1-10<br />

SNB 11-77<br />

SNBD 11-91, 13-25<br />

SND6A100LI 7-134<br />

I-26<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

I<br />

PRODUCT<br />

INDEX<br />

SPD6B140LIG 7-137<br />

SPD6B140LSI 7-137<br />

SPD6B140LSIG 7-137<br />

SPD6B160LI 7-137<br />

SPD6B160LIG 7-137<br />

SPD6B160LSI 7-137<br />

SPD6B160LSIG 7-137<br />

SPT1 3-102<br />

SPT3 3-102<br />

SQR 11-77<br />

SQRC 11-77, 11-91, 13-26<br />

SQRD 11-91<br />

SRSS 2-25, 2-76, 3-130<br />

SRSTD 2-25, 2-51, 2-77, 3-130<br />

SRSW 2-25, 2-51, 2-76, 2-77, 3-130<br />

SS251CR 2-8<br />

SS351CR 2-8<br />

SS451CR 2-8<br />

SSBP 7-211<br />

SSBPH 7-211<br />

SSCJ 11-77<br />

SSCL 11-77<br />

SSCLD 11-91<br />

SSH075 4-22<br />

SSH100 4-22<br />

SSH125 4-22<br />

SSH150 4-22<br />

SSH200 4-22<br />

SSH250 4-22<br />

SSH300 4-22<br />

SSH350 4-22<br />

SSH400 4-22<br />

SSJ1 11-77<br />

SSJ1D 11-91<br />

SSL6 11-77<br />

SSL6D 11-91<br />

SSMND 11-91, 13-25<br />

SSRK33 5-13<br />

SSRK34 5-13<br />

SND6A100LIG 7-134<br />

SND6A100LIGH 7-134<br />

SND6A100LIH 7-134<br />

SND6A100LSI 7-134<br />

SND6A100LSIG 7-134<br />

SND6A100LSIGH 7-134<br />

SND6A100LSIH 7-134<br />

SND6A120LI 7-134<br />

SND6A120LIG 7-134<br />

SND6A120LIGH 7-134<br />

SND6A120LIH 7-134<br />

SND6A120LSI 7-134<br />

SND6A120LSIG 7-134<br />

SND6A120LSIGH 7-134<br />

SND6A120LSIH 7-134<br />

SND6A800LI 7-134<br />

SND6A800LIG 7-134<br />

SND6A800LIGH 7-134<br />

SND6A800LIH 7-134<br />

SND6A800LSI 7-134<br />

SND6A800LSIG 7-134<br />

SND6A800LSIGH 7-134<br />

SND6A800LSIH 7-134<br />

SND6B100LI 7-134<br />

SND6B100LIG 7-134<br />

SND6B100LIGH 7-134<br />

SND6B100LIH 7-134<br />

SND6B100LSI 7-134<br />

SND6B100LSIG 7-134<br />

SND6B100LSIGH 7-134<br />

SND6B100LSIH 7-134<br />

SND6B120LI 7-134<br />

SND6B120LIG 7-134<br />

SND6B120LIGH 7-134<br />

SND6B120LIH 7-134<br />

SND6B120LSI 7-134<br />

SND6B120LSIG 7-134<br />

SND6B120LSIGH 7-134<br />

SND6B120LSIH 7-134<br />

SND6B800LI 7-134<br />

SND6B800LIG 7-134<br />

SND6B800LIGH 7-134<br />

SND6B800LIH 7-134<br />

SND6B800LSI 7-134<br />

SND6B800LSIG 7-134<br />

SND6B800LSIGH 7-134<br />

SND6B800LSIH 7-134<br />

SNW0816B1200T 1-9<br />

SNW0816L1200T 1-10<br />

SNW1212L1125 1-10<br />

SNW1224B1100 1-9<br />

SNW1224B1125 1-9<br />

SNW1224B1200 1-9<br />

SNW1224L1125 1-10<br />

SNW1224L1200 1-10<br />

SNW1224L1225 1-10<br />

SNW1632B1100 1-9<br />

SNW1632L1125 1-10<br />

SNW2020B1100 1-9<br />

SNW2040B1125 1-9<br />

SNW2040B1150 1-9<br />

SNW2040B1200 1-9<br />

SNW2040C1200 1-11<br />

SNW2040L1125 1-10<br />

SNW2040L1150 1-10<br />

SNW2040L1200 1-10<br />

SNW2424B1125 1-9<br />

SNW2424C1125 1-11<br />

SNW2424L1125 1-10<br />

SNW3048B1125 1-9<br />

SNW3048B1150 1-9<br />

SNW3048B1200 1-9<br />

SNW3048C1200 1-11<br />

SNW3048L1125 1-10<br />

SNW3048L1200 1-10<br />

SNW4040B1150 1-9<br />

SNW4040B1200 1-9<br />

SNW4040C1200 1-11<br />

SNW4040L1200 1-10<br />

SNW4264B1225 1-9<br />

SNW4264L1225 1-10<br />

SPD6A140LI 7-137<br />

SPD6A140LIG 7-137<br />

SPD6A140LSI 7-137<br />

SPD6A140LSIG 7-137<br />

SPD6A160LI 7-137<br />

SPD6A160LIG 7-137<br />

SPD6A160LSI 7-137<br />

SPD6A160LSIG 7-137<br />

SPD6B140LI 7-137<br />

STRLB24DC 7-178, 7-182,<br />

7-186, 7-190, 7-219<br />

STRLC60DC 7-178, 7-182,<br />

7-186, 7-190, 7-219<br />

STRLD125DC 7-178, 7-182,<br />

7-186, 7-190, 7-219<br />

STRLE250DC 7-178, 7-182,<br />

7-186, 7-190, 7-219<br />

STRLM60 7-178, 7-182,<br />

7-186, 7-190, 7-219<br />

STRLN120 7-178, 7-182,<br />

7-186, 7-190, 7-219<br />

STRLS277 7-178, 7-182,<br />

7-186, 7-190, 7-219<br />

STRLV600 7-178, 7-182,<br />

7-186, 7-190, 7-219<br />

STRPB24DC 7-194, 7-198, 7-201, 7-219<br />

STRPC60DC 7-194, 7-198, 7-201, 7-219<br />

STRPD125DC 7-194, 7-198, 7-201, 7-219<br />

STRPE250DC 7-194, 7-198, 7-201, 7-219<br />

STRPM60 7-194, 7-198, 7-201, 7-219<br />

STRPN120 7-194, 7-198, 7-201, 7-219<br />

STRPS277 7-194, 7-198, 7-201, 7-219<br />

STRPV600 7-194, 7-198, 7-201, 7-219<br />

SW1224B3100 1-15<br />

SW1224L3125 1-15<br />

SW1224L3200 1-15<br />

SW1836L3150 1-15<br />

SW2442B3150 1-15<br />

SW2442L3150 1-15<br />

SW2442L3200 1-15<br />

SW3054B3200 1-15<br />

SW3054L3200 1-15<br />

SW4242B3225 1-15<br />

SW4260B3200 1-15<br />

SW4260L3225 1-15<br />

SX087M 2-82<br />

SX302A1 15-11<br />

SX302A2 15-11<br />

SX302A3 15-11<br />

SX302C1 15-11<br />

SX302C2 15-11<br />

SX302C3 15-11<br />

SX304A1 15-11<br />

SX304A2 15-11<br />

SX304A3 15-11<br />

SX304C1 15-11<br />

SX304C2 15-11<br />

SX304C3 15-11<br />

SX306A1 15-11<br />

SX306A2 15-11<br />

SX306A3 15-11<br />

SX306C1 15-11<br />

SX306C2 15-11<br />

SX306C3 15-11<br />

SX308A1 15-11<br />

SX308A2 15-11<br />

SX308A3 15-11<br />

SX308C1 15-11<br />

SX308C2 15-11<br />

SX308C3 15-11<br />

SX310A1 15-11<br />

SX310A2 15-11<br />

SX310A3 15-11<br />

SX310C1 15-11<br />

SX310C2 15-11<br />

SX310C3 15-11<br />

SX312A1 15-11<br />

SX312A2 15-11<br />

SX312A3 15-11<br />

SX312C1 15-11<br />

SX312C2 15-11<br />

SX312C3 15-11<br />

SX313A1 15-11<br />

SX313A2 15-11<br />

SX313A3 15-11<br />

SX313C1 15-11<br />

SX313C2 15-11<br />

SX313C3 15-11<br />

SX316A1 15-11<br />

SX316A2 15-11<br />

SX316A3 15-11<br />

SX316C1 15-11<br />

SX316C2 15-11<br />

SX316C3 15-11<br />

SX320A1 15-11<br />

SX320A2 15-11<br />

SX320A3 15-11<br />

SX320C1 15-11<br />

SX320C2 15-11<br />

SX320C3 15-11<br />

SX325A1 15-11<br />

SX325A2 15-11<br />

SX325A3 15-11<br />

SX325C1 15-11<br />

SX325C2 15-11<br />

SX325C3 15-11<br />

SX330A1 15-11<br />

SX330A2 15-11<br />

SX330A3 15-11<br />

SX330C1 15-11<br />

SX330C2 15-11<br />

SX330C3 15-11<br />

SX332A1 15-11<br />

SX332A2 15-11<br />

SX332A3 15-11<br />

SX332C1 15-11<br />

SX332C2 15-11<br />

SX332C3 15-11<br />

SX340A1 15-11<br />

SX340A2 15-11<br />

SX340A3 15-11<br />

SX340C1 15-11<br />

SX340C2 15-11<br />

SX340C3 15-11<br />

SX350C1 15-11<br />

SX350C2 15-11<br />

SX350C3 15-11<br />

SX402A1 15-11<br />

SX402A2 15-11<br />

SX402A3 15-11<br />

SX402C1 15-11<br />

SX402C2 15-11<br />

SX402C3 15-11<br />

SX404A1 15-11<br />

SX404A2 15-11<br />

SX404A3 15-11<br />

SX404C1 15-11<br />

SX404C2 15-11<br />

SX404C3 15-11<br />

SX406A1 15-11<br />

SX406A2 15-11<br />

SX406A3 15-11<br />

SX406C1 15-11<br />

SX406C2 15-11<br />

SX406C3 15-11<br />

SX408A1 15-11<br />

SX408A2 15-11<br />

SX408A3 15-11<br />

SX408C1 15-11<br />

SX408C2 15-11<br />

SX408C3 15-11<br />

SX410A1 15-11<br />

SX410A2 15-11<br />

SX410A3 15-11<br />

SX410C1 15-11<br />

SX410C2 15-11<br />

SX410C3 15-11<br />

SX412A1 15-11<br />

SX412A2 15-11<br />

SX412A3 15-11<br />

SX412C1 15-11<br />

SX412C2 15-11<br />

SX412C3 15-11<br />

SX413A1 15-11<br />

SX413A2 15-11<br />

SX413A3 15-11<br />

SX413C1 15-11<br />

SX413C2 15-11<br />

SX413C3 15-11<br />

SX416A1 15-11<br />

SX416A2 15-11<br />

SX416A3 15-11<br />

SX416C1 15-11<br />

SX416C2 15-11<br />

SX416C3 15-11<br />

SX420A1 15-11<br />

SX420A2 15-11<br />

SX420A3 15-11<br />

SX420C1 15-11<br />

SX420C2 15-11<br />

SX420C3 15-11<br />

SX425A1 15-11<br />

SX425A2 15-11<br />

SX425A3 15-11<br />

SX425C1 15-11<br />

SX425C2 15-11<br />

SX425C3 15-11<br />

SX430A1 15-11<br />

SX430A2 15-11<br />

SX430A3 15-11<br />

SX430C1 15-11<br />

SX430C2 15-11<br />

SX430C3 15-11<br />

SX432A1 15-11<br />

SX432A2 15-11<br />

SX432A3 15-11<br />

SX432C1 15-11<br />

SX432C2 15-11<br />

SX432C3 15-11<br />

SX440A1 15-11<br />

SX440A2 15-11<br />

SX440A3 15-11<br />

SX440C1 15-11<br />

SX440C2 15-11<br />

SX440C3 15-11<br />

SX450C1 15-11<br />

SX450C2 15-11<br />

SX450C3 15-11<br />

SX502A1 15-11<br />

SX502A2 15-11<br />

SX502A3 15-11<br />

SX502C1 15-11<br />

SX502C2 15-11<br />

SX502C3 15-11<br />

SX504A1 15-11<br />

SX504A2 15-11<br />

SX504A3 15-11<br />

SX504C1 15-11<br />

SX504C2 15-11<br />

SX504C3 15-11<br />

SX506A1 15-11<br />

SX506A2 15-11<br />

SX506A3 15-11<br />

SX506C1 15-11<br />

SX506C2 15-11<br />

SX506C3 15-11<br />

SX508A1 15-11<br />

SX508A2 15-11<br />

SX508A3 15-11<br />

SX508C1 15-11<br />

SX508C2 15-11<br />

SX508C3 15-11<br />

SX510A1 15-11<br />

SX510A2 15-11<br />

SX510A3 15-11<br />

SX510C1 15-11<br />

SX510C2 15-11<br />

SX510C3 15-11<br />

SX512A1 15-11<br />

SX512A2 15-11<br />

SX512A3 15-11<br />

SX512C1 15-11<br />

SX512C2 15-11<br />

SX512C3 15-11<br />

SX513A1 15-11<br />

SX513A2 15-11<br />

SX513A3 15-11<br />

SX513C1 15-11<br />

SX513C2 15-11<br />

SX513C3 15-11<br />

SX516A1 15-11<br />

SX516A2 15-11<br />

SX516A3 15-11<br />

SX516C1 15-11<br />

SX516C2 15-11<br />

SX516C3 15-11<br />

SX520A1 15-11<br />

SX520A2 15-11<br />

SX520A3 15-11<br />

SX520C1 15-11<br />

SX520C2 15-11<br />

SX520C3 15-11<br />

SX525A1 15-11<br />

SX525A2 15-11<br />

SX525A3 15-11<br />

SX525C1 15-11<br />

SX525C2 15-11<br />

SX525C3 15-11<br />

SX530A1 15-11<br />

SX530A2 15-11<br />

SX530A3 15-11<br />

SX530C1 15-11<br />

SX530C2 15-11<br />

SX530C3 15-11<br />

SX532A1 15-11<br />

SX532A2 15-11<br />

SX532A3 15-11<br />

SX532C1 15-11<br />

SX532C2 15-11<br />

SX532C3 15-11<br />

SX540A1 15-11<br />

SX540A2 15-11<br />

SX540A3 15-11<br />

SX540C1 15-11<br />

SX540C2 15-11<br />

SX540C3 15-11<br />

SX550C1 15-11<br />

SX550C2 15-11<br />

SX550C3 15-11<br />

SXDRA1 15-26<br />

SXDRA2 15-26<br />

SXDRA3 15-26<br />

SXDRA4 15-26<br />

SXDRA5 15-26<br />

SXDRA6 15-26<br />

SXDRA7 15-26<br />

SXDRC1 15-26<br />

SXDRC2 15-26<br />

SXDRC3 15-26<br />

SXDRC4 15-26<br />

SXDRC5 15-26<br />

SXDRC6 15-26<br />

SXDRC7 15-26<br />

SXSK 15-46, 15-52<br />

SXSS1 15-26<br />

SXSS2 15-26<br />

SXSS3 15-26<br />

SXSS4 15-26<br />

SXTH1 15-25<br />

SXTH2 15-25<br />

SXTH3 15-25<br />

SXTH4 15-25<br />

SXWH1 15-27<br />

SXWH2 15-27<br />

SXWH3 15-27<br />

SXWH4 15-27<br />

TA12JG04 7-213<br />

TA1DG30 6-4, 6-7, 7-212<br />

TA1E6125 6-3, 7-111, 7-154<br />

TA1FD350A 6-4, 6-7, 7-114, 7-154<br />

TA1JG750 7-213<br />

TA1L6750 7-117, 7-119, 7-121, 7-155<br />

TA1Q1 1-48, 7-153, 7-158, 7-39<br />

TA1QR300 6-3, 6-7<br />

TA2J630 7-119, 7-154<br />

TA2J6500 6-4, 6-5, 6-7, 7-117,<br />

7-119, 7-121, 7-154<br />

TA2JG250 7-213<br />

TA2JG250PT 7-213<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog I-27


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

I<br />

PRODUCT<br />

INDEX<br />

TA2K500 5-27, 7-125, 7-128, 7-130,<br />

7-132, 7-154<br />

TA2MG750 7-213<br />

TA2N750 7-125, 7-154<br />

TA3DG02 7-212<br />

TA3FG20 7-212<br />

TA3H750 5-27<br />

TA3K500 5-27, 6-5, 6-6, 6-7, 7-125,<br />

7-128, 7-130, 7-132, 7-154<br />

TA3MG500 7-213<br />

TA3MG500PT 7-213<br />

TA4H500 5-27<br />

TA4P750 7-136, 7-155, 7-199, 7-213<br />

TA5P500 6-7<br />

TA5P600 6-6, 7-136, 7-137,<br />

7-154, 7-199, 7-213<br />

TA6DG04 7-212<br />

TA6ED06 7-155<br />

TA6FD04 7-155<br />

TA6FG04 7-212<br />

TA6GG04 7-155<br />

TA6JD20 7-155<br />

TA6JG20 7-213<br />

TA6R600 7-136, 7-137, 7-139,<br />

7-154, 7-199, 7-213<br />

TAW1FG350 6-4, 6-7, 7-212<br />

TBNK4 15-20<br />

TBNK6 15-20<br />

TBNK8 15-20<br />

TC1DG30 7-212<br />

TC1ED6150 7-111, 7-155<br />

TC1FD350 7-114, 7-155<br />

TC1J6600 7-117, 7-119, 7-121, 7-155<br />

TC1JG750 7-183, 7-213<br />

TC1Q1 1-48, 7-33, 7-34, 7-39,<br />

7-43, 7-153, 7-158<br />

TC2J6500 7-117, 7-119, 7-121, 7-155<br />

TC2JG250 7-183, 7-213<br />

TC2K500 5-27, 7-128, 7-130, 7-132,<br />

7-155<br />

TC3K350 5-27<br />

TC3MG500 7-191, 7-213<br />

TC5R600 6-6, 6-7, 7-136, 7-137,<br />

7-139, 7-155, 7-199, 7-213<br />

TCE3 7-165<br />

TCF29B 11-102<br />

TCF3 7-165<br />

TCF41B 11-102<br />

TCF47B 11-102<br />

TCF59B 11-102<br />

TCH65K 1-48, 7-158<br />

TCJ3 7-165<br />

TCL3 7-165<br />

TCM3 7-165<br />

TCN3 7-165<br />

TCS29B 11-102<br />

TCS41B 11-102<br />

TCS47B 11-102<br />

TCS59B 11-102<br />

TCW1FG350 7-212<br />

TFAK32 15-83, 5-26<br />

TFAK35 15-83, 5-26<br />

TFAK42 15-83, 5-26<br />

TFAK45 15-83, 5-26<br />

TFAK72 4-20, 5-27<br />

TFAK75 4-20, 5-26, 5-27<br />

TFAK82 4-20, 5-27<br />

TFP223 5-29<br />

TFP224 5-29<br />

TFP323 5-29<br />

TFP324 5-29<br />

TFP363 5-29<br />

TFP364 5-29<br />

THEL 7-217<br />

THEM 7-217<br />

THEP 7-217<br />

TL137NP 2-16<br />

TL137RT 2-16<br />

TL137U2P 2-16<br />

TL137UP 2-16<br />

TL137UP-LP 2-16<br />

TL137US 2-16<br />

TL138GUP 2-16<br />

TL17US 2-16<br />

TL1F3F7UP 2-16<br />

TL1F3F7US 2-16<br />

TL1F3F7US2 2-16<br />

TL1F77NT 2-16<br />

TL1F77RB 2-16<br />

TL1F7US 2-16<br />

TL37US 2-16<br />

TL577NT 2-16<br />

TL577US 2-16<br />

TL5F77NT 2-16<br />

TL5F77RB 2-16<br />

TL5F77RT 2-16<br />

TL5F8G8GUS 2-16<br />

TL77NB 2-16<br />

TL77NT 2-16<br />

TL77RB 2-16<br />

TL77RT 2-16<br />

TL77US 2-16<br />

TLATVP 2-16<br />

TLAWATER 2-16<br />

TLK14Q 8-27<br />

TLK15Q 8-27<br />

TLK34Q 8-27<br />

TLK35Q 8-27<br />

TLK36Q 8-27<br />

TLK37Q 8-27<br />

TLK38Q 8-27<br />

TLK39Q 8-27<br />

TMK606 5-12<br />

TMK610 5-12<br />

TMK610C 5-12<br />

TMK620 5-12<br />

TMK620C 5-12<br />

TMKJ 7-213<br />

TMKJ3 7-213<br />

TNKD 7-212<br />

TNKD3 7-212<br />

TNKF 7-212<br />

TNKF3 7-212<br />

TNKG3 7-153, 7-43<br />

TNKL 7-213<br />

TNKL3 7-213<br />

TNKM 7-213<br />

TNKM3 7-213<br />

TNKP 7-213<br />

TNKP3 7-213<br />

TPS3 01 10-8<br />

TPS3 02 10-9<br />

TPS3 03 1-51, 10-10<br />

TPS3 03 DC 10-11<br />

TPS3 05 10-12<br />

TPS3 06 10-13<br />

TPS3 09 10-14<br />

TPS3 11 10-15<br />

TPS3 12 10-16<br />

TPS3 15 10-17<br />

TPS3 L1 10-8<br />

TPS3 L12 10-16<br />

TPS3 L15 10-17<br />

TPS3 L2 10-9<br />

TPS3 L5 10-12<br />

TPS3 L6 10-13<br />

TSLF3 7-210<br />

TSLL3 7-211<br />

TSLM3 7-211<br />

TSLP3 7-211<br />

TSSF3 7-210<br />

TSSG3A 7-160<br />

TSSL3 7-211<br />

TSSM3 7-211<br />

TSSP3 7-211<br />

TW1DG20 7-212<br />

TW1FG350 7-212<br />

TW1JG600 7-213<br />

TWB15J 8-27<br />

TWB75J 8-27<br />

U01ED60 7-113<br />

U01ED62A 7-113<br />

U01ED62AA 7-113<br />

U01ED62AB 7-113<br />

U01ED62B 7-113<br />

U01FD60 7-116<br />

U01JLD6 7-120, 7-124, 7-127<br />

U01JLD62A 7-120, 7-124, 7-127<br />

U01JLD62AA 7-120, 7-124, 7-127<br />

U01MN6 7-131, 7-135, 7-138<br />

U01MN64A 7-131, 7-135, 7-138<br />

U01MN64AA 7-131, 7-135, 7-138<br />

U02ED60 7-113<br />

U02ED62A 7-113<br />

U02ED62AA 7-113<br />

U02ED62AB 7-113<br />

U02ED62B 7-113<br />

U02FD60 7-116<br />

U02JLD6 7-120, 7-124, 7-127<br />

U02JLD62A 7-120, 7-124, 7-127<br />

U02JLD62AA 7-120, 7-124, 7-127<br />

U02MN6 7-131, 7-135, 7-138<br />

U02MN64A 7-131, 7-135, 7-138<br />

U02MN64AA 7-131, 7-135, 7-138<br />

U03ED60 7-113<br />

U03ED62A 7-113<br />

U03ED62AA 7-113<br />

U03ED62AB 7-113<br />

U03ED62B 7-113<br />

U03JLD6 7-120, 7-124, 7-127<br />

U03JLD62A 7-120, 7-124, 7-127<br />

U03JLD62AA 7-120, 7-124, 7-127<br />

U03MN6 7-131, 7-135, 7-138<br />

U03MN64A 7-131, 7-135, 7-138<br />

U03MN64AA 7-131, 7-135, 7-138<br />

U04MN6 7-131, 7-135, 7-138<br />

U04MN64A 7-131, 7-135, 7-138<br />

U04MN64AA 7-131, 7-135, 7-138<br />

U06ED60 7-113<br />

U06ED64A 7-113<br />

U06ED64AB 7-113<br />

U06ED64B 7-113<br />

U06FD60 7-116<br />

U06JLD6 7-120, 7-124, 7-127<br />

U06JLD64A 7-120, 7-124, 7-127<br />

U06JLD64AA 7-120, 7-124, 7-127<br />

U06MN6 7-131, 7-135, 7-138<br />

U07MN6 7-131, 7-135, 7-138<br />

U07MN64A 7-131, 7-135, 7-138<br />

U07MN64AA 7-131, 7-135, 7-138<br />

U08ED60 7-113<br />

U09MN6 7-131, 7-135, 7-138<br />

U09MN64A 7-131, 7-135, 7-138<br />

U09MN64AA 7-131, 7-135, 7-138<br />

U10ED60 7-113<br />

U10ED62A 7-113<br />

U10ED62AA 7-113<br />

U10ED62AB 7-113<br />

U10ED62B 7-113<br />

U10FD60 7-116<br />

U10JLD6 7-120, 7-124, 7-127<br />

U10JLD62A 7-120, 7-124, 7-127<br />

U10JLD62AA 7-120, 7-124, 7-127<br />

U11MN6 7-131, 7-135, 7-138<br />

U11MN64A 7-131, 7-135, 7-138<br />

U11MN64AA 7-131, 7-135, 7-138<br />

U12ED60 7-113<br />

U12ED62A 7-113<br />

U12ED62AA 7-113<br />

U13ED60 7-113<br />

U13ED62A 7-113<br />

U13ED62AA 7-113<br />

U13ED62AB 7-113<br />

U13ED62B 7-113<br />

U13FD60 7-116<br />

U13JLD6 7-120, 7-124, 7-127<br />

U13JLD62A 7-120, 7-124, 7-127<br />

U13JLD62AA 7-120, 7-124, 7-127<br />

U14ED60 7-113<br />

U14ED62A 7-113<br />

U14ED62AA 7-113<br />

U14ED62AB 7-113<br />

U14ED62B 7-113<br />

U14FD60 7-116<br />

U14JLD6 7-120, 7-124, 7-127<br />

U14JLD62A 7-120, 7-124, 7-127<br />

U14JLD62AA 7-120, 7-124, 7-127<br />

U15MN6 7-131, 7-135, 7-138<br />

U15MN64A 7-131, 7-135, 7-138<br />

U15MN64AA 7-131, 7-135, 7-138<br />

U16ED60 7-113<br />

U16ED64A 7-113<br />

U16ED64AB 7-113<br />

U16ED64B 7-113<br />

U16FD60 7-116<br />

UA2311-0PGP 2-7<br />

UA2311-0PQG 2-7<br />

UA2717-YPDN 2-7<br />

UA2717-YPGP 2-7<br />

UA2717-YPQG 2-7<br />

UA2717-YPZA 2-7<br />

UA3311-0PGP 2-7<br />

UA3311-0PQG 2-7<br />

UA3717-YPDN 2-7<br />

UA3717-YPGP 2-7<br />

UA3717-YPZA 2-7<br />

UA4311-0PGP 2-7<br />

UA4311-0PQG 2-7<br />

UA4719-YPDN 2-7<br />

UA4719-YPGP 2-7<br />

UA4719-YPQG 2-7<br />

UA4719-YPZA 2-7<br />

UA5719-KPDN 2-7<br />

UA5719-KPGP 2-7<br />

UA6719-KPQG 2-7<br />

UA6719-KPZA 2-7<br />

UAB111-0PCH 2-12<br />

UAB111-100 2-12<br />

UAB111-125 2-12<br />

UAB111-XG 2-12<br />

UAB317-0PCH 2-12<br />

UAB417-150 2-12<br />

UAB417-200 2-12<br />

UAB417-XG 2-12<br />

UAB417-XPG 2-12<br />

UAB877-200 2-12<br />

UAB877-PG 2-12<br />

UAP317-PPWI 2-12<br />

UAPB317-PPWI 2-12<br />

UAS817-PPGP 2-6<br />

UAS818-PGNM 2-6<br />

UAS877-PG 2-6<br />

UAS877-PPCV 2-6<br />

UAS877-PPDN 2-6<br />

UAS877-PPGP 2-6<br />

UAS877-PPZ 2-6<br />

UAS877-PPZA 2-6<br />

UAS917-XJCA 2-6<br />

UAT111-0G 2-5<br />

UAT111-0GF 2-5<br />

UAT111-0JCA 2-5<br />

UAT111-0MXA 2-5<br />

UAT111-0PDN 2-5<br />

UAT111-0PGP 2-5<br />

UAT111-0PQG 2-5<br />

UAT111-0PV 2-5<br />

UAT111-0PZA 2-5<br />

UAT111-PG 2-5<br />

UAT121-0BCO 2-5<br />

UAT121-0GWR 2-5<br />

UAT121-BBCO 2-5<br />

UAT121-BGWR 2-5<br />

UAT121-BM 2-5<br />

UAT121-PBCO 2-5<br />

UAT121-PGWR 2-5<br />

UAT317-0FP 2-6<br />

UAT317-0G 2-6<br />

UAT317-0GF 2-6<br />

UAT317-0MXA 2-6<br />

UAT317-0PDN 2-6<br />

UAT317-0PGP 2-6<br />

UAT317-0PQG 2-6<br />

UAT317-0PZA 2-6<br />

UAT317-DGZ 2-6<br />

UAT327-0GWR 2-6<br />

UAT327-0MCO 2-6<br />

UAT417-0PQG 2-6<br />

UAT417-PG 2-6<br />

UAT417-XFP 2-6<br />

UAT417-XG 2-6<br />

UAT417-XGDU 2-6<br />

UAT417-XGF 2-6<br />

UAT417-XPCV 2-6<br />

UAT417-XPQG 2-6<br />

UAT427-PMCO 2-6<br />

UAT427-XMWR 2-6<br />

UAT517-PDG 2-6<br />

UAT618-XGNM 2-6<br />

UBT20 2-81<br />

UBT30 2-81<br />

UBT40 2-81<br />

UBT50 2-81<br />

UCP1216 2-82<br />

UE145 15-81, 15-82<br />

UE155 15-81, 15-82<br />

UE175 15-81, 15-82<br />

UE195 15-81, 15-82<br />

UE275 15-81, 15-82<br />

UE295 15-81, 15-82<br />

UEC3100G 15-83<br />

UEC4100G 15-83<br />

UEW1216 2-82<br />

UF145 15-81, 15-82<br />

UF155 15-81, 15-82<br />

UF175 15-81, 15-82<br />

UF195 15-81, 15-82<br />

UF275 15-81, 15-82<br />

UF295 15-81, 15-82<br />

UFC3250G 15-83<br />

UFC4250G 15-83<br />

UFS145 15-81, 15-82<br />

UFS179 15-81, 15-82<br />

UFS275 15-82<br />

UFS279 15-81, 15-82<br />

UH145 15-81, 15-82<br />

UH155 15-81, 15-82<br />

UH175 15-81, 15-82<br />

UH195 15-81, 15-82<br />

UH275 15-81, 15-82<br />

UH295 15-81, 15-82<br />

UH302AB 15-81<br />

UH302CB 15-82<br />

UH304AB 15-81<br />

UH304CB 15-82<br />

UH306AB 15-81<br />

UH306CB 15-82<br />

UH308AV 15-81<br />

UH308CV 15-82<br />

UH310AV 15-81<br />

UH310CV 15-82<br />

UH312AV 15-81<br />

UH312CV 15-82<br />

UH313AV 15-81<br />

UH313CV 15-82<br />

UH316AV 15-81<br />

UH316CV 15-82<br />

UH320AV 15-81<br />

UH320CV 15-82<br />

UH325AV 15-81<br />

UH325CV 15-82<br />

UH330AV 15-81<br />

UH330CV 15-82<br />

UH340AV 15-81<br />

UH340CV 15-82<br />

UH350AV 15-81<br />

UH350CV 15-82<br />

UH360CV 15-82<br />

UH365CV 15-82<br />

UH502AB 15-81<br />

UH502CB 15-82<br />

UH504AB 15-81<br />

UH504CB 15-82<br />

UH506AB 15-81<br />

UH506CB 15-82<br />

UH508AV 15-81<br />

UH508CV 15-82<br />

UH510AV 15-81<br />

UH510CV 15-82<br />

UH512AV 15-81<br />

UH512CV 15-82<br />

UH513AV 15-81<br />

UH513CV 15-82<br />

UH516AV 15-81<br />

UH516CV 15-82<br />

UH520AV 15-81<br />

UH520CV 15-82<br />

UH525AV 15-81<br />

UH525CV 15-82<br />

UH530AV 15-81<br />

UH530CV 15-82<br />

UH540AV 15-81<br />

UH540CV 15-82<br />

UH550AV 15-81<br />

UH550CV 15-82<br />

UH560CV 15-82<br />

UH565CV 15-82<br />

UJ100 15-80<br />

UK1000TA 2-51, 2-76, 2-77<br />

UK350TA 2-51, 2-76, 2-77<br />

UK600TA 2-51, 2-76, 2-77<br />

ULK1350 2-82<br />

ULK1500 2-82<br />

ULK2500 2-82<br />

ULT10SP 2-82<br />

ULT20 2-81<br />

ULT30 2-81<br />

ULT40 2-81<br />

ULT50 2-81<br />

UMBCVR 2-82<br />

UMCVR 2-82<br />

UPB12 2-81<br />

UPB3 2-81<br />

UPB6 2-81<br />

US2:9410D24VDC 9-9<br />

US2:9410DC 9-9<br />

US2:9410DCAN 9-9<br />

US2:9410R24VDC 9-9<br />

US2:9410RC 9-9<br />

US2:9410SK 9-9<br />

US2:9410T24VDC 9-9<br />

I-28<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

US2:9410TC 9-9<br />

US2:948DCAB10 9-9<br />

US2:948DISP96 9-9<br />

US2:948M2AO4AI 9-9<br />

US2:948M2DO6DI 9-9<br />

US2:94PMAK 9-9<br />

US2:94PMHWK 9-9<br />

US2:94PMHWKDC 9-9<br />

US2:94PMRDHWK 9-9<br />

US2:ECPLD3R 1-48, 7-158<br />

US2:ENCL3124001TCX 9-12<br />

US2:ENCL3148012TCX 9-12<br />

US2:ENCL3224001TCX 9-12<br />

US2:ENCL3248012TCX 9-12<br />

US2:MDBM 9-23<br />

US2:MDBMD 9-23<br />

US2:MDBMIP 9-23<br />

US2:MDBMIPD 9-23<br />

US2:PWRSP4A 9-7, 9-8<br />

US2:SCTHMC0100U 9-23<br />

US2:SCTHMC0200U 9-23<br />

US2:SCTHSC0050U 9-23<br />

US2:SCTR161310U 9-23<br />

US2:SCTR241310U 9-23<br />

US2:SCTR361310U 9-23<br />

US2:SCTSCL0600U 9-23<br />

US2:SCTSCL1000U 9-23<br />

US2:SCTSCM0100U 9-23<br />

US2:SCTSCM0200U 9-23<br />

US2:SCTSCM0400U 9-23<br />

US2:SCTSCM0600U 9-23<br />

US2:SCTSCS0050U 9-23<br />

US2:SCTSCS0100U 9-23<br />

US2:SEM303ENCL1 9-21<br />

US2:SEM303ENCL12 9-21<br />

US2:SEM303ENCL1D 9-22<br />

US2:SEM303ENCL1DS 9-22<br />

US2:SEM303ENCL4 9-21<br />

US2:SEM309ENCL1 9-21<br />

US2:SEM309ENCL12 9-21<br />

US2:SEM309ENCL1D 9-22<br />

US2:SEM309ENCL1DS 9-22<br />

US2:SEM309ENCL4 9-21<br />

US2:SEM315ENCL1 9-21<br />

US2:SEM315ENCL12 9-21<br />

US2:SEM315ENCL1D 9-22<br />

US2:SEM315ENCL1DS 9-22<br />

US2:SEM315ENCL4 9-21<br />

US2:SEM318ENCL1 9-21<br />

US2:SEM318ENCL12 9-21<br />

US2:SEM318ENCL1D 9-22<br />

US2:SEM318ENCL1DS 9-22<br />

US2:SEM318ENCL4 9-21<br />

US2:SEM321ENCL1 9-21<br />

US2:SEM321ENCL12 9-21<br />

US2:SEM321ENCL1D 9-22<br />

US2:SEM321ENCL1DS 9-22<br />

US2:SEM321ENCL4 9-21<br />

US2:SEM3301ENCL1D 9-22<br />

US2:SEM330ENCL1 9-21<br />

US2:SEM330ENCL12 9-21<br />

US2:SEM330ENCL1DS 9-22<br />

US2:SEM330ENCL4 9-21<br />

US2:SEM342ENCL1 9-21<br />

US2:SEM342ENCL12 9-21<br />

US2:SEM342ENCL1D 9-22<br />

US2:SEM342ENCL1DS 9-22<br />

US2:SEM342ENCL4 9-21<br />

US2:SEM345ENCL1 9-21<br />

US2:SEM345ENCL12 9-21<br />

US2:SEM345ENCL1D 9-22<br />

US2:SEM345ENCL1DS 9-22<br />

US2:SEM345ENCL4 9-21<br />

US2:SEM3CAB10FT 9-14<br />

US2:SEM3CAB12INCH 9-14<br />

US2:SEM3CAB20FT 9-14<br />

US2:SEM3CAB24INCH 9-14<br />

US2:SEM3CAB36INCH 9-14<br />

US2:SEM3CAB5FT 9-14<br />

US2:SEM3CAB6INCH 9-14<br />

US2:SEM3CONTROLLER 9-14, 9-15<br />

US2:SEM3PHAMETER 9-14, 9-16<br />

US2:SEM3PLAMETER 9-14, 9-16<br />

US2:SEM3RACK15 9-14, 9-15<br />

US2:SEM3RACK21 9-14, 9-15<br />

US2:SEM3RACK3 9-14, 9-15<br />

US2:SEM3RACK6 9-15<br />

US2:SEM3RACK9 9-14, 9-15<br />

US2:SEM3SCCT1200 9-14, 9-16<br />

US2:SEM3SCCT125 9-14, 9-16<br />

US2:SEM3SCCT1600 9-14, 9-16<br />

US2:SEM3SCCT2000 9-14, 9-16<br />

US2:SEM3SCCT250 9-14, 9-16<br />

US2:SEM3SCCT400 9-14, 9-16<br />

US2:SEM3SCCT50 9-14, 9-16<br />

US2:SEM3SCCT600 9-14, 9-16<br />

US2:SEM3SCCT800 9-14, 9-16<br />

US2:SEM3TOUCHP12 9-22<br />

US2:SEM3TOUCHP15 9-22<br />

US2:SEM3TOUCHP19 9-22<br />

US2:SEM3TOUCHP7 9-22<br />

US2:SEM3TOUCHP9 9-22<br />

US2:SEM3TP12AEN 9-22<br />

US2:SEM3TP12AENUL 9-22<br />

US2:SEM3TP12SEN 9-22<br />

US2:SEM3TP12SENUL 9-22<br />

US2:SEM3TP7AEN 9-22<br />

US2:SEM3TP7AENUL 9-22<br />

US2:SEM3TP7SEN 9-22<br />

US2:SEM3TP7SENUL 9-22<br />

US2:SEM3TP9AEN 9-22<br />

US2:SEM3TP9AENUL 9-22<br />

US2:SEM3TP9SEN 9-22<br />

US2:SEM3TP9SENUL 9-22<br />

UV321G 15-83<br />

UV322G 15-83<br />

UV323G 15-83<br />

UV324G 15-83<br />

UV361G 15-83<br />

UV362G 15-83<br />

UV363G 15-83<br />

UV364G 15-83<br />

UV421G 15-83<br />

UV422G 15-83<br />

UV423G 15-83<br />

UV424G 15-83<br />

UV461G 15-83<br />

UV462G 15-83<br />

UV463G 15-83<br />

UV464G 15-83<br />

UVRLA12DC 7-178, 7-182,<br />

7-186, 7-190, 7-219<br />

UVRLB24DC 7-178, 7-182,<br />

7-186, 7-190, 7-219<br />

UVRLC48DC 7-178, 7-182,<br />

7-186, 7-190, 7-219<br />

UVRLD125DC 7-178, 7-182, 7-186,<br />

7-190, 7-219<br />

UVRLE250DC 7-178, 7-182,<br />

7-186, 7-190, 7-219<br />

UVRLG60DC 7-178, 7-182,<br />

7-186, 7-190, 7-219<br />

UVRLL24 7-178, 7-182,<br />

7-186, 7-190, 7-219<br />

UVRLN120 7-178, 7-182,<br />

7-186, 7-190, 7-219<br />

UVRLP208 7-178, 7-182,<br />

7-186, 7-190, 7-219<br />

UVRLR240 7-178, 7-182,<br />

7-186, 7-190, 7-219<br />

UVRLS277 7-178, 7-182,<br />

7-186, 7-190, 7-219<br />

UVRLT415 7-178, 7-182,<br />

7-186, 7-190, 7-219<br />

UVRLU480 7-178, 7-182,<br />

7-186, 7-190, 7-219<br />

UVRPA12DC 7-194, 7-198, 7-201, 7-219<br />

UVRPB24DC 7-194, 7-198, 7-201, 7-219<br />

UVRPC48DC 7-194, 7-198, 7-201, 7-219<br />

UVRPD125DC 7-194, 7-198, 7-201, 7-219<br />

UVRPE250DC 7-194, 7-198, 7-201, 7-219<br />

UVRPG60DC 7-194, 7-198, 7-201, 7-219<br />

UVRPN120 7-194, 7-198, 7-201, 7-219<br />

UVRPP208 7-194, 7-198, 7-201, 7-219<br />

UVRPR240 7-194, 7-198, 7-201, 7-219<br />

UVRPS277 7-194, 7-198, 7-201, 7-219<br />

UVRPT415 7-194, 7-198, 7-201, 7-219<br />

UVRPU480 7-194, 7-198, 7-201, 7-219<br />

UVS210 2-80<br />

UVS310 2-80<br />

UVS311B 2-80<br />

UVS410 2-80<br />

UVS411B 2-80<br />

UVS510 2-80<br />

UVS511B 2-80<br />

UX001WL 2-50<br />

UX005B 2-25, 2-50<br />

V2A2211LR 5-23<br />

V2A3211 5-23<br />

V2B2211LR 5-23<br />

V2B2212LR 5-23<br />

V2B2222LR 5-23<br />

V2B3211 5-23<br />

V2B3211R 5-23<br />

V2B3212 5-23<br />

V2B3212R 5-23<br />

V2B3222 5-23<br />

V2B3222R 5-23<br />

V2E2203LR 5-23<br />

V2E2204LR 5-23<br />

V2E3203 5-23<br />

V2F3204 5-23<br />

V2F3204MS 5-23<br />

V7A2211__ 5-24<br />

V7A3211 5-24<br />

V7B2211_ 5-24<br />

V7B2211LR 5-24<br />

V7B2212LR 5-24<br />

V7B2212LRR 5-24<br />

V7B2222_ 5-24<br />

V7B2222__ 5-24<br />

V7B3211 5-24<br />

V7B3211R 5-24<br />

V7B3212 5-24<br />

V7B3212R 5-24<br />

V7B3222 5-24<br />

V7B3222R 5-24<br />

V7E2204__ 5-24<br />

V7E2223LR 5-24<br />

V7E2233__ 5-24<br />

V7E2603LR 5-25<br />

V7E2611LR 5-25<br />

V7E2612LR 5-25<br />

V7E3202 5-24<br />

V7E3203 5-24<br />

V7E3223 5-24<br />

V7E3233 5-24<br />

V7E3233R 5-24<br />

V7E3601 5-25<br />

V7E3602 5-25<br />

V7E3603 5-25<br />

V7E3611 5-25<br />

V7E3611R 5-25<br />

V7E3612 5-25<br />

V7E3622 5-25<br />

V7E3622R 5-25<br />

V7E3623 5-25<br />

V7E3633 5-25<br />

V7E3633R 5-25<br />

V7F3204 5-24<br />

V7F3205A 5-24<br />

V7F3244R 5-24<br />

V7F3604 5-25<br />

V7F3604R 5-25<br />

V7F3605A 5-25<br />

V7F3644 5-24<br />

V7F3644J 5-25<br />

V7FBB65A 5-26<br />

V7H2205A 5-24<br />

V7H2206A 5-24<br />

V7H3205A 5-24<br />

V7H3206A 5-24<br />

V7H3605A 5-25<br />

V7H3606A 5-25<br />

V7HBB65A 5-26<br />

V7HBB66A 5-26<br />

VB357TL 5-25<br />

VB358TL 5-25<br />

VB610 13-26, 5-26<br />

VB6150 13-26<br />

VB657 13-26, 5-26<br />

VB671 13-26, 5-26<br />

VBFCL3 5-26<br />

VBFCL4 5-26<br />

VBFS321 5-11, 5-8<br />

VBFS321F 5-11, 5-8<br />

VBFS322 5-11, 5-8<br />

VBFS322F 5-11, 5-8<br />

VBFS361 5-11, 5-8<br />

VBFS361F 5-11, 5-8<br />

VBFS361FPV 5-11, 5-8<br />

VBFS361PV 5-11, 5-8<br />

VBFS362 5-11, 5-8<br />

VBFS362F 5-11, 5-8<br />

VBFS362FPV 5-11, 5-8<br />

VBFS362PV 5-11, 5-8<br />

VBFS363 5-11, 5-8<br />

VBFS363F 5-11, 5-8<br />

VBFS363FPV 5-11, 5-8<br />

VBFS363PV 5-11, 5-8<br />

VBFS364 5-11, 5-8<br />

VBFS364F 5-11, 5-8<br />

VBFS365 5-11, 5-8<br />

VBFS366 5-11, 5-8<br />

VBH1 5-9<br />

VBH112 5-9<br />

VBH14 5-9<br />

VBH14X 5-9<br />

VBH2 5-9<br />

VBH24X 5-9<br />

VBH2R 5-9<br />

VBHM1 5-8<br />

VBHM2 5-8<br />

VBHM2X 5-8<br />

VBLK1 5-9<br />

VBLK2 5-9<br />

VBLK3 5-9<br />

VBLK4 5-9<br />

VBNFS361 5-11, 5-8<br />

VBNFS361F 5-11, 5-8<br />

VBNFS361FPV 5-11, 5-8<br />

VBNFS361PV 5-11, 5-8<br />

VBNFS362 5-11, 5-8<br />

VBNFS362F 5-11, 5-8<br />

VBNFS362FPV 5-11, 5-8<br />

VBNFS362PV 5-11, 5-8<br />

VBNFS363 5-11, 5-8<br />

VBNFS363F 5-11, 5-8<br />

VBNFS363FPV 5-11, 5-8<br />

VBNFS363PV 5-11, 5-8<br />

VBNFS364 5-11, 5-8<br />

VBNFS364F 5-11, 5-8<br />

VBNFS365 5-11, 5-8<br />

VBNFS366 5-11, 5-8<br />

VBRHK1232 5-26<br />

VBRHK41 5-26<br />

VBRHK42 5-26<br />

VBRL4 5-26<br />

VBWK1 5-9<br />

VBWK2 5-9<br />

VBWK3 5-9<br />

VC1COMMA 19-7<br />

VC2COMMA 19-7<br />

VC30GRYHW 19-3<br />

VC30GRYU 19-3<br />

VCCMSDP 19-3<br />

VCCMSSP 19-3<br />

VCDATA103 19-7<br />

VCDATA105 19-7<br />

VCDATA153 19-7<br />

VCDATA155 19-7<br />

VCDATA53 19-7<br />

VCDATA55 19-7<br />

VCMNTGBRK 19-3<br />

VCPOSTGRY 19-3<br />

VCPOSTGRY2 19-3<br />

VCSG30GCPUW 19-3<br />

VCSG30GRYUW 19-3<br />

VF357TL 5-25<br />

VF358TL 5-25<br />

VMS325B 5-24<br />

VMS325T 5-24<br />

VMS326B 5-24<br />

VMS326T 5-24<br />

VMS365B 5-25<br />

VMS365T 5-25<br />

VMS366B 5-25<br />

VMS366T 5-25<br />

W01FD64 7-116<br />

W0202MB1100CU 1-20<br />

W0202MB1150CU 1-20<br />

W0202MB1200CU 1-20<br />

W0202ML1200CU 1-20<br />

W0204MB1100 1-19<br />

W0204ML1060 1-20, 6-10<br />

W0204ML1125CU 1-20<br />

W02FD64 7-116<br />

W0303ML3100 1-20, 6-10<br />

W03FD64 7-116<br />

W0404MB1150CTS 1-19<br />

W0404MB1200CT 1-19<br />

W0404MB1200CTS 1-19<br />

W0406ML1225CU 1-20, 6-10<br />

W0408L1125SPA50 1-19<br />

W0408L1125SPA60 1-19<br />

W0408ML1125 1-19<br />

W0606ML1400CU 1-16<br />

W06FD64 7-116<br />

W0816ML1125CU 1-19<br />

W10FD64 7-116<br />

W13FD64 7-116<br />

W14FD64 7-116<br />

W16FD64 7-116<br />

W3030MB1400CU 1-16<br />

W3030ML1400CU 1-16<br />

W3042B1200GEN 1-17<br />

W3042L1225GEN 1-17<br />

W4242MB1400CU 1-16<br />

W4242MB3400CU 1-16<br />

W4242ML1400CU 1-16<br />

W4242ML3400CU 1-16<br />

W43000 5-26<br />

W43002 5-26<br />

W48762 5-26<br />

W48763 5-26<br />

W48764 5-26<br />

W48765 5-26<br />

W49818 15-83, 5-26<br />

W49819 15-83, 5-26<br />

W49827 15-83, 5-26<br />

W49828 15-83, 5-26<br />

W49830 15-83, 5-26<br />

W49832 15-83, 5-26<br />

W53045 6-11, 6-12, 6-13, 6-3,<br />

6-4, 6-7, 6-9<br />

W55365 15-83, 5-26<br />

W55366 15-83, 5-26<br />

W56623 5-26<br />

W56626 15-83<br />

W56627 15-83<br />

W56628 15-83, 5-26<br />

W56629 15-83, 5-26<br />

W60992 6-11, 6-13, 6-4, 6-7, 6-9, 7-118<br />

W60993 6-11, 6-12, 6-13, 6-5,<br />

6-7, 6-9, 7-122<br />

W62890 15-76<br />

W63231 15-83<br />

W63232 15-83<br />

W63233 15-83<br />

W63623 6-11, 6-13, 6-5, 6-6,<br />

6-7, 6-9, 7-126, 7-128, 7-132<br />

W68101 15-76<br />

WB11000B 3-17<br />

WB11000BU 3-17<br />

WB11000C 3-15<br />

WB11000CNH 3-15<br />

WB11000CU 3-15<br />

WB11000CUNH 3-15<br />

WB11000T 3-17<br />

WB11000TNH 3-17<br />

WB11000TU 3-17<br />

WB11000TUNH 3-17<br />

WB11200B 3-17<br />

WB11200BU 3-17<br />

WB11200C 3-15<br />

WB11200CNH 3-15<br />

WB11200CU 3-15<br />

WB11200CUNH 3-15<br />

WB11200T 3-17<br />

WB11200TNH 3-17<br />

WB11200TU 3-17<br />

WB11200TUNH 3-17<br />

WB11400B 3-15<br />

WB11400BU 3-15<br />

WB11400T 3-15<br />

WB11400TNH 3-15<br />

WB11400TU 3-15<br />

WB11400TUNH 3-15<br />

WB11600B 3-15<br />

WB11600BU 3-15<br />

WB11600T 3-15<br />

WB11600TNH 3-15<br />

WB11600TU 3-15<br />

WB11600TUNH 3-15<br />

WB11800B 3-15<br />

WB11800BU 3-15<br />

WB11800W 3-15<br />

WB11800WNH 3-15<br />

WB11800WU 3-15<br />

WB11800WUNH 3-15<br />

WB12000B 3-15<br />

WB12000BU 3-15<br />

WB12000W 3-15<br />

WB12000WNH 3-15<br />

WB12000WU 3-15<br />

WB12000WUNH 3-15<br />

WB1200B 3-17<br />

WB1200BU 3-17<br />

WB1200C 3-15<br />

I<br />

PRODUCT<br />

INDEX<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog I-29


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

I<br />

PRODUCT<br />

INDEX<br />

WB1200CNH 3-15<br />

WB1200CU 3-15<br />

WB1200CUNH 3-15<br />

WB1200T 3-17<br />

WB1200TNH 3-17<br />

WB1200TU 3-17<br />

WB1200TUNH 3-17<br />

WB1250B 3-17<br />

WB1250BU 3-17<br />

WB1250C 3-15<br />

WB1250CNH 3-15<br />

WB1250CU 3-15<br />

WB1250CUNH 3-15<br />

WB1250T 3-17<br />

WB1250TNH 3-17<br />

WB1250TU 3-17<br />

WB1250TUNH 3-17<br />

WB1300B 3-17<br />

WB1300BU 3-17<br />

WB1300C 3-15<br />

WB1300CNH 3-15<br />

WB1300CU 3-15<br />

WB1300CUNH 3-15<br />

WB1300T 3-17<br />

WB1300TNH 3-17<br />

WB1300TU 3-17<br />

WB1300TUNH 3-17<br />

WB1350B 3-17<br />

WB1350BU 3-17<br />

WB1350C 3-15<br />

WB1350CNH 3-15<br />

WB1350CU 3-15<br />

WB1350CUNH 3-15<br />

WB1350T 3-17<br />

WB1350TNH 3-17<br />

WB1350TU 3-17<br />

WB1350TUNH 3-17<br />

WB1400B 3-17<br />

WB1400BU 3-17<br />

WB1400C 3-15<br />

WB1400CNH 3-15<br />

WB1400CU 3-15<br />

WB1400CUNH 3-15<br />

WB1400T 3-17<br />

WB1400TNH 3-17<br />

WB1400TU 3-17<br />

WB1400TUNH 3-17<br />

WB1450B 3-17<br />

WB1450BU 3-17<br />

WB1450C 3-15<br />

WB1450CNH 3-15<br />

WB1450CU 3-15<br />

WB1450CUNH 3-15<br />

WB1450T 3-17<br />

WB1450TNH 3-17<br />

WB1450TU 3-17<br />

WB1450TUNH 3-17<br />

WB1500B 3-17<br />

WB1500BU 3-17<br />

WB1500C 3-15<br />

WB1500CNH 3-15<br />

WB1500CU 3-15<br />

WB1500CUNH 3-15<br />

WB1500T 3-17<br />

WB1500TNH 3-17<br />

WB1500TU 3-17<br />

WB1500TUNH 3-17<br />

WB1600B 3-17<br />

WB1600BU 3-17<br />

WB1600C 3-15<br />

WB1600CNH 3-15<br />

WB1600CU 3-15<br />

WB1600CUNH 3-15<br />

WB1600T 3-17<br />

WB1600TNH 3-17<br />

WB1600TU 3-17<br />

WB1600TUNH 3-17<br />

WB1700B 3-17<br />

WB1700BU 3-17<br />

WB1700C 3-15<br />

WB1700CNH 3-15<br />

WB1700CU 3-15<br />

WB1700CUNH 3-15<br />

WB1700T 3-17<br />

WB1700TNH 3-17<br />

WB1700TU 3-17<br />

WB1700TUNH 3-17<br />

WB1800B 3-17<br />

WB1800BU 3-17<br />

WB1800C 3-15<br />

WB1800CNH 3-15<br />

WB1800CU 3-15<br />

WB1800CUNH 3-15<br />

WB1800T 3-17<br />

WB1800TNH 3-17<br />

WB1800TU 3-17<br />

WB1800TUNH 3-17<br />

WB1900B 3-17<br />

WB1900BU 3-17<br />

WB1900C 3-15<br />

WB1900CNH 3-15<br />

WB1900CU 3-15<br />

WB1900CUNH 3-15<br />

WB1900T 3-17<br />

WB1900TNH 3-17<br />

WB1900TU 3-17<br />

WB1900TUNH 3-17<br />

WB2150BQR 1-20<br />

WB2200BQR 1-20<br />

WB2225BQR 1-20<br />

WB3100 1-20, 6-10, 7-39<br />

WB31000B 3-18<br />

WB31000BU 3-18<br />

WB31000C 3-16<br />

WB31000CNH 3-16<br />

WB31000CU 3-16<br />

WB31000CUNH 3-16<br />

WB31000T 3-18<br />

WB31000TNH 3-18<br />

WB31000TU 3-18<br />

WB31000TUNH 3-18<br />

WB31200B 3-18<br />

WB31200BU 3-18<br />

WB31200C 3-16<br />

WB31200CNH 3-16<br />

WB31200CU 3-16<br />

WB31200CUNH 3-16<br />

WB31200T 3-18<br />

WB31200TNH 3-18<br />

WB31200TU 3-18<br />

WB31200TUNH 3-18<br />

WB31400B 3-16<br />

WB31400BU 3-16<br />

WB31400T 3-16<br />

WB31400TNH 3-16<br />

WB31400TU 3-16<br />

WB31400TUNH 3-16<br />

WB31600B 3-16<br />

WB31600BU 3-16<br />

WB31600T 3-16<br />

WB31600TNH 3-16<br />

WB31600TU 3-16<br />

WB31600TUNH 3-16<br />

WB31800B 3-16<br />

WB31800BU 3-16<br />

WB31800W 3-16<br />

WB31800WNH 3-16<br />

WB31800WU 3-16<br />

WB31800WUNH 3-16<br />

WB32000B 3-16<br />

WB32000BU 3-16<br />

WB32000W 3-16<br />

WB32000WNH 3-16<br />

WB32000WU 3-16<br />

WB32000WUNH 3-16<br />

WB3200B 3-18<br />

WB3200BU 3-18<br />

WB3200C 3-16<br />

WB3200CNH 3-16<br />

WB3200CU 3-16<br />

WB3200CUNH 3-16<br />

WB3200T 3-18<br />

WB3200TNH 3-18<br />

WB3200TU 3-18<br />

WB3200TUNH 3-18<br />

WB3250B 3-18<br />

WB3250BU 3-18<br />

WB3250C 3-16<br />

WB3250CNH 3-16<br />

WB3250CU 3-16<br />

WB3250CUNH 3-16<br />

WB3250T 3-18<br />

WB3250TNH 3-18<br />

WB3250TU 3-18<br />

WB3250TUNH 3-18<br />

WB3300B 3-18<br />

WB3300BU 3-18<br />

WB3300C 3-16<br />

WB3300CNH 3-16<br />

WB3300CU 3-16<br />

WB3300CUNH 3-16<br />

WB3300T 3-18<br />

WB3300TNH 3-18<br />

WB3300TU 3-18<br />

WB3300TUNH 3-18<br />

WB3350B 3-18<br />

WB3350BU 3-18<br />

WB3350C 3-16<br />

WB3350CNH 3-16<br />

WB3350CU 3-16<br />

WB3350CUNH 3-16<br />

WB3350T 3-18<br />

WB3350TNH 3-18<br />

WB3350TU 3-18<br />

WB3350TUNH 3-18<br />

WB3400B 3-18<br />

WB3400BU 3-18<br />

WB3400C 3-16<br />

WB3400CNH 3-16<br />

WB3400CU 3-16<br />

WB3400CUNH 3-16<br />

WB3400T 3-18<br />

WB3400TNH 3-18<br />

WB3400TU 3-18<br />

WB3400TUNH 3-18<br />

WB3450B 3-18<br />

WB3450BU 3-18<br />

WB3450C 3-16<br />

WB3450CNH 3-16<br />

WB3450CU 3-16<br />

WB3450CUNH 3-16<br />

WB3450T 3-18<br />

WB3450TNH 3-18<br />

WB3450TU 3-18<br />

WB3450TUNH 3-18<br />

WB3500B 3-18<br />

WB3500BU 3-18<br />

WB3500C 3-16<br />

WB3500CNH 3-16<br />

WB3500CU 3-16<br />

WB3500CUNH 3-16<br />

WB3500T 3-18<br />

WB3500TNH 3-18<br />

WB3500TU 3-18<br />

WB3500TUNH 3-18<br />

WB3600B 3-18<br />

WB3600BU 3-18<br />

WB3600C 3-16<br />

WB3600CNH 3-16<br />

WB3600CU 3-16<br />

WB3600CUNH 3-16<br />

WB3600T 3-18<br />

WB3600TNH 3-18<br />

WB3600TU 3-18<br />

WB3600TUNH 3-18<br />

WB3700B 3-18<br />

WB3700BU 3-18<br />

WB3700C 3-16<br />

WB3700CNH 3-16<br />

WB3700CU 3-16<br />

WB3700CUNH 3-16<br />

WB3700T 3-18<br />

WB3700TNH 3-18<br />

WB3700TU 3-18<br />

WB3700TUNH 3-18<br />

WB3800B 3-18<br />

WB3800BU 3-18<br />

WB3800C 3-16<br />

WB3800CNH 3-16<br />

WB3800CU 3-16<br />

WB3800CUNH 3-16<br />

WB3800T 3-18<br />

WB3800TNH 3-18<br />

WB3800TU 3-18<br />

WB3800TUNH 3-18<br />

WB3900B 3-18<br />

WB3900BU 3-18<br />

WB3900C 3-16<br />

WB3900CNH 3-16<br />

WB3900CU 3-16<br />

WB3900CUNH 3-16<br />

WB3900T 3-18<br />

WB3900TNH 3-18<br />

WB3900TU 3-18<br />

WB3900TUNH 3-18<br />

WBM11200B 3-17<br />

WBM11200BU 3-17<br />

WBM11200C 3-15<br />

WBM11200CNH 3-15<br />

WBM11200CU 3-15<br />

WBM11200CUNH 3-15<br />

WBM11200T 3-17<br />

WBM11200TNH 3-17<br />

WBM11200TU 3-17<br />

WBM11200TUNH 3-17<br />

WBM11400B 3-15<br />

WBM11400T 3-15<br />

WBM11400TNH 3-15<br />

WBM11400TUNH 3-15<br />

WBM11600B 3-15<br />

WBM11600T 3-15<br />

WBM11600TNH 3-15<br />

WBM11600TUNH 3-15<br />

WBM11800B 3-15<br />

WBM11800BU 3-15<br />

WBM11800W 3-15<br />

WBM11800WNH 3-15<br />

WBM11800WU 3-15<br />

WBM11800WUNH 3-15<br />

WBM12000B 3-15<br />

WBM12000BU 3-15<br />

WBM12000W 3-15<br />

WBM12000WNH 3-15<br />

WBM12000WU 3-15<br />

WBM12000WUNH 3-15<br />

WBM31200B 3-18<br />

WBM31200BU 3-18<br />

WBM31200C 3-16<br />

WBM31200CNH 3-16<br />

WBM31200CU 3-16<br />

WBM31200CUNH 3-16<br />

WBM31200T 3-18<br />

WBM31200TNH 3-18<br />

WBM31200TU 3-18<br />

WBM31200TUNH 3-18<br />

WBM31400B 3-16<br />

WBM31400BU 3-16<br />

WBM31400T 3-16<br />

WBM31400TNH 3-16<br />

WBM31400TU 3-16<br />

WBM31400TUNH 3-16<br />

WBM31600B 3-16<br />

WBM31600BU 3-16<br />

WBM31600T 3-16<br />

WBM31600TNH 3-16<br />

WBM31600TU 3-16<br />

WBM31600TUNH 3-16<br />

WBM31800B 3-16<br />

WBM31800BU 3-16<br />

WBM31800W 3-16<br />

WBM31800WNH 3-16<br />

WBM31800WU 3-16<br />

WBM31800WUNH 3-16<br />

WBM32000B 3-16<br />

WBM32000BU 3-16<br />

WBM32000W 3-16<br />

WBM32000WNH 3-16<br />

WBM32000WU 3-16<br />

WBM32000WUNH 3-16<br />

WBT312X200 3-28<br />

WBT312X200NH 3-28<br />

WBT312X200U 3-28<br />

WBT312X200UNH 3-28<br />

WBT312X250 3-28<br />

WBT312X250NH 3-28<br />

WBT312X250U 3-28<br />

WBT312X250UNH 3-28<br />

WBT312X300 3-28<br />

WBT312X300NH 3-28<br />

WBT312X300U 3-28<br />

WBT312X300UNH 3-28<br />

WBT312X350 3-28<br />

WBT312X350NH 3-28<br />

WBT312X350U 3-28<br />

WBT312X350UNH 3-28<br />

WBT312X400 3-28<br />

WBT312X400NH 3-28<br />

WBT312X400U 3-28<br />

WBT312X400UNH 3-28<br />

WBT312X450 3-28<br />

WBT312X450NH 3-28<br />

WBT312X450U 3-28<br />

WBT312X450UNH 3-28<br />

WBT312X500 3-28<br />

WBT312X500NH 3-28<br />

WBT312X500U 3-28<br />

WBT312X500UNH 3-28<br />

WBT312X600 3-28<br />

WBT312X600NH 3-28<br />

WBT312X600U 3-28<br />

WBT312X600UNH 3-28<br />

WBT324X1000 3-28<br />

WBT324X1000NH 3-28<br />

WBT324X1000U 3-28<br />

WBT324X1000UNH 3-28<br />

WBT324X1200 3-28<br />

WBT324X1200NH 3-28<br />

WBT324X1200U 3-28<br />

WBT324X1200UNH 3-28<br />

WBT324X200 3-28<br />

WBT324X200NH 3-28<br />

WBT324X200U 3-28<br />

WBT324X200UNH 3-28<br />

WBT324X250 3-28<br />

WBT324X250NH 3-28<br />

WBT324X250U 3-28<br />

WBT324X250UNH 3-28<br />

WBT324X300 3-28<br />

WBT324X300NH 3-28<br />

WBT324X300U 3-28<br />

WBT324X300UNH 3-28<br />

WBT324X350 3-28<br />

WBT324X350NH 3-28<br />

WBT324X350U 3-28<br />

WBT324X350UNH 3-28<br />

WBT324X400 3-28<br />

WBT324X400NH 3-28<br />

WBT324X400U 3-28<br />

WBT324X400UNH 3-28<br />

WBT324X450 3-28<br />

WBT324X450NH 3-28<br />

WBT324X450U 3-28<br />

WBT324X450UNH 3-28<br />

WBT324X500 3-28<br />

WBT324X500NH 3-28<br />

WBT324X500U 3-28<br />

WBT324X500UNH 3-28<br />

WBT324X600 3-28<br />

WBT324X600NH 3-28<br />

WBT324X600U 3-28<br />

WBT324X600UNH 3-28<br />

WBT324X700 3-28<br />

WBT324X700NH 3-28<br />

WBT324X700U 3-28<br />

WBT324X700UNH 3-28<br />

WBT324X800 3-28<br />

WBT324X800NH 3-28<br />

WBT324X800U 3-28<br />

WBT324X800UNH 3-28<br />

WBT324X900 3-28<br />

WBT324X900NH 3-28<br />

WBT324X900U 3-28<br />

WBT324X900UNH 3-28<br />

WBTM324X12 3-28<br />

WBTM324X12NH 3-28<br />

WBTM324X12U 3-28<br />

WBTM324X12UNH 3-28<br />

WC2040B1T1 3-80<br />

WC2040B1T1R 3-81<br />

WC2040B1T1RJ 3-81<br />

WC2040B1T1RJB 3-81<br />

WC2040B1T2 3-80<br />

WC2040B1T2R 3-81<br />

WC2040B1T2RJ 3-81<br />

WC2040B1T2RJB 3-81<br />

WC2040B1T3 3-80<br />

WC2040B1T3R 3-81<br />

WC2040B1T3RJ 3-81<br />

WC2040B1T3RJB 3-81<br />

WC2040B1T4 3-80<br />

WC2040B1T4R 3-81<br />

WC2040B1T4RJ 3-81<br />

WC2040B1T4RJB 3-81<br />

WC2040B1T5 3-80<br />

WC2040B1T5R 3-81<br />

WC2040B1T5RJ 3-81<br />

WC2040B1T5RJB 3-81<br />

WC2040B1T6 3-80<br />

WC2040B1T6R 3-81<br />

WC2040B1T6RJ 3-81<br />

WC2040B1T6RJB 3-81<br />

WC2040B1T7 3-80<br />

WC2040B1T7R 3-81<br />

WC2040B1T7RJ 3-81<br />

WC2040B1T7RJB 3-81<br />

WC2040B1T8 3-80<br />

WC2040B1T8R 3-81<br />

WC2040B1T8RJ 3-81<br />

WC2040B1T8RJB 3-81<br />

WC2040B1T9 3-80<br />

I-30<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

WC2040B1T9R 3-81<br />

WC2040B1T9RJ 3-81<br />

WC2040B1T9RJB 3-81<br />

WC2040B2T1J 3-80<br />

WC2040B2T1RJ 3-81<br />

WC2040B2T1RJB 3-81<br />

WC2040B2T2J 3-80<br />

WC2040B2T2RJ 3-81<br />

WC2040B2T2RJB 3-81<br />

WC2040B2T3J 3-80<br />

WC2040B2T3RJ 3-81<br />

WC2040B2T3RJB 3-81<br />

WC2040B2T4J 3-80<br />

WC2040B2T4RJ 3-81<br />

WC2040B2T4RJB 3-81<br />

WC2040B2T5J 3-80<br />

WC2040B2T5RJ 3-81<br />

WC2040B2T5RJB 3-81<br />

WC2040B2T6J 3-80<br />

WC2040B2T6RJ 3-81<br />

WC2040B2T6RJB 3-81<br />

WC2040B2T7J 3-80<br />

WC2040B2T7RJ 3-81<br />

WC2040B2T7RJB 3-81<br />

WC2040B2T8J 3-80<br />

WC2040B2T8RJ 3-81<br />

WC2040B2T8RJB 3-81<br />

WC2040B2T9J 3-80<br />

WC2040B2T9RJ 3-81<br />

WC2040B2T9RJB 3-81<br />

WCL2040B1T1RJ 3-84<br />

WCL2040B1T2RJ 3-84<br />

WCL2040B1T3RJ 3-84<br />

WCL2040B1T4RJ 3-84<br />

WCL2040B1T5RJ 3-84<br />

WCL2040B1T6RJ 3-84<br />

WCL2040B1T7RJ 3-84<br />

WCL2040B1T8RJ 3-84<br />

WCL2040B1T9RJ 3-84<br />

WCL2040B2T1RJ 3-84<br />

WCL2040B2T2RJ 3-84<br />

WCL2040B2T3RJ 3-84<br />

WCL2040B2T4RJ 3-84<br />

WCL2040B2T5RJ 3-84<br />

WCL2040B2T6RJ 3-84<br />

WCL2040B2T7RJ 3-84<br />

WCL2040B2T8RJ 3-84<br />

WCL2040B2T9RJ 3-84<br />

WCL2442B3T1RJ 3-84<br />

WCL2442B3T2RJ 3-84<br />

WCL2442B3T3RJ 3-84<br />

WCL2442B3T4RJ 3-84<br />

WCL2442B3T5RJ 3-84<br />

WCL2442B3T6RJ 3-84<br />

WCL2442B3T7RJ 3-84<br />

WCL2442B3T8RJ 3-84<br />

WCL2442B3T9RJ 3-84<br />

WCT2040B1T1 3-87<br />

WCT2040B1T2 3-87<br />

WCT2040B1T3 3-87<br />

WCT2040B1T4 3-87<br />

WCT2040B1T5 3-87<br />

WCT2040B1T6 3-87<br />

WCT2040B1T7 3-87<br />

WCT2040B1T8 3-87<br />

WCT2040B1T9 3-87<br />

WCT2040B2T1J 3-87<br />

WCT2040B2T2J 3-87<br />

WCT2040B2T3J 3-87<br />

WCT2040B2T4J 3-87<br />

WCT2040B2T5J 3-87<br />

WCT2040B2T6J 3-87<br />

WCT2040B2T7J 3-87<br />

WCT2040B2T8J 3-87<br />

WCT2040B2T9J 3-87<br />

WCT2442B3T1J 3-87<br />

WCT2442B3T2J 3-87<br />

WCT2442B3T3J 3-87<br />

WCT2442B3T4J 3-87<br />

WCT2442B3T5J 3-87<br />

WCT2442B3T6J 3-87<br />

WCT2442B3T7J 3-87<br />

WCT2442B3T8J 3-87<br />

WCT2442B3T9J 3-87<br />

WEB11000B 3-21<br />

WEB11000BU 3-21<br />

WEB11200B 3-21<br />

WEB11200BU 3-21<br />

WEB1200B 3-21<br />

WEB1200BU 3-21<br />

WEB1250B 3-21<br />

WEB1250BU 3-21<br />

WEB1300B 3-21<br />

WEB1300BU 3-21<br />

WEB1350B 3-21<br />

WEB1350BU 3-21<br />

WEB1400B 3-21<br />

WEB1400BU 3-21<br />

WEB1500B 3-21<br />

WEB1500BU 3-21<br />

WEB1600B 3-21<br />

WEB1600BU 3-21<br />

WEB1700B 3-21<br />

WEB1700BU 3-21<br />

WEB1800B 3-21<br />

WEB1800BU 3-21<br />

WEB1900B 3-21<br />

WEB1900BU 3-21<br />

WEB31000B 3-22<br />

WEB31000BU 3-22<br />

WEB31200B 3-22<br />

WEB31200BU 3-22<br />

WEB3200B 3-22<br />

WEB3200BU 3-22<br />

WEB3250B 3-22<br />

WEB3250BU 3-22<br />

WEB3300B 3-22<br />

WEB3300BU 3-22<br />

WEB3350B 3-22<br />

WEB3350BU 3-22<br />

WEB3400B 3-22<br />

WEB3400BU 3-22<br />

WEB3500B 3-22<br />

WEB3500BU 3-22<br />

WEB3600B 3-22<br />

WEB3600BU 3-22<br />

WEB3700B 3-22<br />

WEB3700BU 3-22<br />

WEB3800B 3-22<br />

WEB3800BU 3-22<br />

WEB3900B 3-22<br />

WEB3900BU 3-22<br />

WEBM11200B 3-21<br />

WEBM11200BU 3-21<br />

WEBM31200B 3-22<br />

WEBM31200BU 3-22<br />

WELB107E 3-102<br />

WELB112 3-102<br />

WELB118 3-102<br />

WELB307E 3-102<br />

WELB312 3-102<br />

WELB318 3-102<br />

WEP10612 3-109<br />

WEP2211 3-109<br />

WEP2212EV 3-109<br />

WEP3311 3-109<br />

WEP4212 3-109<br />

WEP4312 3-109<br />

WEP4411 3-109<br />

WEP4412 3-109<br />

WEP4511 3-109<br />

WEP4611 3-109<br />

WEP6412 3-109<br />

WEP6511 3-109<br />

WEP6512 3-109<br />

WEP6611 3-109<br />

WEP6612 3-109<br />

WEP8612 3-109<br />

WES11200BU 3-37<br />

WES1400BU 3-37<br />

WES1600BU 3-37<br />

WES1800BU 3-37<br />

WES31200BU 3-37<br />

WES3400BU 3-37<br />

WES3600BU 3-37<br />

WES3800BU 3-37<br />

WET11200BU 3-47<br />

WET1400BU 3-47<br />

WET1800BU 3-47<br />

WET31200BU 3-47<br />

WET3400BU 3-47<br />

WET3800BU 3-47<br />

WF2030 1-53<br />

WF2030GFCI 1-53<br />

WF2030PL 1-53<br />

WF2060 1-53<br />

WF2060GFCI 1-53<br />

WF2060PL 1-53<br />

WMEP 3-130<br />

WMK11400R 3-77<br />

WMK11600R 3-77<br />

WMK12400RJ 3-77<br />

WMK13400RJ 3-77<br />

WMK13600RJ 3-77<br />

WMK22400RJ 3-77<br />

WMK23400RJ 3-77<br />

WML11225RJ 3-60<br />

WML11400RJ 3-62<br />

WML11400RJFS 3-64<br />

WML11400RJH 3-62<br />

WML12225RJ 3-60<br />

WML12400RJ 3-62<br />

WML12400RJFS 3-64<br />

WML12400RJH 3-62<br />

WML13100RJ 3-61<br />

WML13225RJ 3-61<br />

WML13400RJ 3-62<br />

WML13400RJFS 3-64<br />

WML13400RJH 3-62<br />

WML21125RJ 3-59<br />

WML21225RJ 3-60<br />

WML21400RJ 3-62<br />

WML22125RJ 3-59<br />

WML22400RJ 3-62<br />

WML22AB225RJ 3-60<br />

WML22BC225RJ 3-60<br />

WML22CA225RJ 3-60<br />

WML23100RJ 3-61<br />

WML23225RJ 3-61<br />

WML23400RJ 3-62<br />

WML31125RJ 3-59<br />

WML31225RJ 3-60<br />

WML32125RJ 3-59<br />

WML32225RJ 3-60<br />

WML33100RJ 3-61<br />

WML33225RJ 3-61<br />

WML41125RJ 3-59<br />

WML41225RJ 3-60<br />

WML42125RJ 3-59<br />

WML42AB225RJ 3-60<br />

WML42BC225RJ 3-60<br />

WML42CA225RJ 3-60<br />

WML43100RJ 3-61<br />

WML43225RJ 3-61<br />

WML51125RJ 3-59<br />

WML52125RJ 3-59<br />

WML61125RJ 3-59<br />

WML62125RJ 3-59<br />

WMLZ32125RJ 3-69<br />

WMLZ42125RJ 3-69<br />

WMLZ52125RJ 3-69<br />

WMLZ62125RJ 3-69<br />

WMLZF32125RJ 3-69<br />

WMLZF42125RJ 3-69<br />

WMLZF52125RJ 3-69<br />

WMLZF62125RJ 3-69<br />

WMM21125 3-53<br />

WMM21125J 3-54<br />

WMM21125R 3-53<br />

WMM21125RB 3-53<br />

WMM21125RJ 3-54<br />

WMM21125RJB 3-54<br />

WMM21225 3-53<br />

WMM21225J 3-54<br />

WMM21225R 3-53<br />

WMM21225RB 3-53<br />

WMM21225RJ 3-54<br />

WMM21225RJB 3-54<br />

WMM22125J 3-55<br />

WMM22125RJ 3-55<br />

WMM22125RJB 3-55<br />

WMM22225J 3-55<br />

WMM22225RJ 3-55<br />

WMM22225RJB 3-55<br />

WMM31125 3-53<br />

WMM31125J 3-54<br />

WMM31125R 3-53<br />

WMM31125RB 3-53<br />

WMM31125RJ 3-54<br />

WMM31125RJB 3-54<br />

WMM31225 3-53<br />

WMM31225J 3-54<br />

WMM31225R 3-53<br />

WMM31225RB 3-53<br />

WMM31225RJ 3-54<br />

WMM31225RJB 3-54<br />

WMM32125J 3-55<br />

WMM32125RJ 3-55<br />

WMM32125RJB 3-55<br />

WMM32225J 3-55<br />

WMM32225RJ 3-55<br />

WMM32225RJB 3-55<br />

WMM41125 3-53<br />

WMM41125J 3-54<br />

WMM41125R 3-53<br />

WMM41125RB 3-53<br />

WMM41125RJ 3-54<br />

WMM41125RJB 3-54<br />

WMM41225 3-53<br />

WMM41225J 3-54<br />

WMM41225R 3-53<br />

WMM41225RB 3-53<br />

WMM41225RJ 3-54<br />

WMM41225RJB 3-54<br />

WMM42125J 3-55<br />

WMM42125RJ 3-55<br />

WMM42125RJB 3-55<br />

WMM42225J 3-55<br />

WMM42225RJ 3-55<br />

WMM42225RJB 3-55<br />

WMM51125 3-53<br />

WMM51125J 3-54<br />

WMM51125R 3-53<br />

WMM51125RB 3-53<br />

WMM51125RJ 3-54<br />

WMM51125RJB 3-54<br />

WMM51225 3-53<br />

WMM51225J 3-54<br />

WMM51225R 3-53<br />

WMM51225RB 3-53<br />

WMM51225RJ 3-54<br />

WMM51225RJB 3-54<br />

WMM52125J 3-55<br />

WMM52125RJ 3-55<br />

WMM52125RJB 3-55<br />

WMM52225J 3-55<br />

WMM52225RJ 3-55<br />

WMM52225RJB 3-55<br />

WMM61125 3-53<br />

WMM61125J 3-54<br />

WMM61125R 3-53<br />

WMM61125RB 3-53<br />

WMM61125RJ 3-54<br />

WMM61125RJB 3-54<br />

WMM61225 3-53<br />

WMM61225J 3-54<br />

WMM61225R 3-53<br />

WMM61225RB 3-53<br />

WMM61225RJ 3-54<br />

WMM61225RJB 3-54<br />

WMM62125J 3-55<br />

WMM62125RJ 3-55<br />

WMM62125RJB 3-55<br />

WMM62225J 3-55<br />

WMM62225RJ 3-55<br />

WMM62225RJB 3-55<br />

WMMB11200 3-99<br />

WMMB1400 3-99<br />

WMMB1800 3-99<br />

WMMB31200 3-99<br />

WMMB3400 3-99<br />

WMMB3800 3-99<br />

WMMBK 3-130<br />

WMN22125J 3-93<br />

WMN22225J 3-93<br />

WMN32125J 3-93<br />

WMN32225J 3-93<br />

WMN42125J 3-93<br />

WMN42225J 3-93<br />

WMN52125J 3-93<br />

WMN52225J 3-93<br />

WMN62125J 3-93<br />

WMN62225J 3-93<br />

WMP024U 3-34<br />

WMP024UNH 3-34<br />

WMP02U 3-34<br />

WMP02UNH 3-34<br />

WMT11225 3-74<br />

WMT12225J 3-74<br />

WMT13225J 3-74<br />

WMT21225 3-74<br />

WMT22AB225J 3-74<br />

WMT22BC225J 3-74<br />

WMT22CA225J 3-74<br />

WMT23225J 3-74<br />

WMT31225 3-74<br />

WMT32225J 3-74<br />

WMT33225J 3-74<br />

WN2060 1-53<br />

WN2060GFCI 1-53<br />

WN2060PL 1-53<br />

WN2060PLX 1-53<br />

WNAS2060 1-53<br />

WNAS2060GFCI 1-53<br />

WNAS2060PL 1-53<br />

WP10612 3-106<br />

WP10612RJ 3-107<br />

WP10612RJB 3-108<br />

WP2211 3-106<br />

WP2211RJ 3-107<br />

WP2211RJB 3-108<br />

WP26 11-38<br />

WP260 11-82<br />

WP275 11-82<br />

WP290 11-82<br />

WP32 11-38<br />

WP3311 3-106<br />

WP3311RJ 3-107<br />

WP3311RJB 3-108<br />

WP38 11-38<br />

WP4212 3-106<br />

WP4212RJ 3-107<br />

WP4212RJB 3-108<br />

WP4312 3-106<br />

WP4312RJ 3-107<br />

WP4312RJB 3-108<br />

WP44 11-38<br />

WP4411 3-106<br />

WP4411RJ 3-107<br />

WP4411RJB 3-108<br />

WP4412 3-106<br />

WP4412RJ 3-107<br />

WP4412RJB 3-108<br />

WP4511 3-106<br />

WP4511RJ 3-107<br />

WP4511RJB 3-108<br />

WP4611 3-106<br />

WP4611RJ 3-107<br />

WP4611RJB 3-108<br />

WP50 11-38<br />

WP5411 3-106, 3-109<br />

WP5411RJ 3-107<br />

WP5411RJB 3-108<br />

WP56 11-38<br />

WP62 11-38<br />

WP6412 3-106<br />

WP6412RJ 3-107<br />

WP6412RJB 3-108<br />

WP6511 3-106<br />

WP6511RJ 3-107<br />

WP6511RJB 3-108<br />

WP6512 3-106<br />

WP6512RJ 3-107<br />

WP6512RJB 3-108<br />

WP6611 3-106<br />

WP6611RJ 3-107<br />

WP6611RJB 3-108<br />

WP6612 3-106<br />

WP6612RJ 3-107<br />

WP6612RJB 3-108<br />

WP68 11-38<br />

WP74 11-38<br />

WP860 11-96<br />

WP8612 3-106<br />

WP8612RJ 3-107<br />

WP8612RJB 3-108<br />

WP875 11-96<br />

WP890 11-96<br />

WPB224 13-17<br />

WPB226 13-17<br />

WPB228 13-17<br />

WPB424 13-17<br />

WPB426 13-17<br />

WPB428 13-17<br />

WPB444 13-17<br />

WPB446 13-17<br />

WPB448 13-17<br />

WPC2211RJB 3-108<br />

WPC4212RJB 3-108<br />

WPC4312RJB 3-108<br />

WPF224 13-18<br />

WPF226 13-18<br />

WPF424 13-18<br />

WPF426 13-18<br />

WPF444 13-18<br />

WPF446 13-18<br />

WPFK1 3-137<br />

WPFK10 3-137<br />

WPFK11 3-137<br />

WPFK12 3-137<br />

I<br />

PRODUCT<br />

INDEX<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog I-31


Product Index<br />

Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s) Catalog Number Page(s)<br />

I<br />

PRODUCT<br />

INDEX<br />

WPFK13 3-137<br />

WPFK2 3-137<br />

WPFK3 3-137<br />

WPFK4 3-137<br />

WPFK5 3-137<br />

WPFK6 3-137<br />

WPFK7 3-137<br />

WPFK8 3-137<br />

WPFK9 3-137<br />

WPL10612RJ 3-110<br />

WT12400PUNH 3-50<br />

WT1400PU 3-50<br />

WT1400PUNH 3-50<br />

WT1800PU 3-50<br />

WT1800PUNH 3-50<br />

WT31200PU 3-50<br />

WT31200PUNH 3-50<br />

WT31600PU 3-50<br />

WT31600PUNH 3-50<br />

WT32000PU 3-50<br />

WXB3350NU 3-25<br />

WXB3400N 3-25<br />

WXB3400NU 3-25<br />

WXB3450N 3-25<br />

WXB3450NU 3-25<br />

WXB3500N 3-25<br />

WXB3500NU 3-25<br />

WXB3600N 3-25<br />

WXB3600NU 3-25<br />

WXB3700N 3-25<br />

WPL4212RJ 3-110<br />

WPL4312RJ 3-110<br />

WPL4412RJ 3-110<br />

WPL6412RJ 3-110<br />

WPL6512RJ 3-110<br />

WPL6612RJ 3-110<br />

WPL8612RJ 3-110<br />

WPLK2400 3-106, 3-107, 3-108, 3-137<br />

WPLK2600 3-106, 3-107, 3-108, 3-137<br />

WT32000PUNH 3-50<br />

WT32400PU 3-50<br />

WT32400PUNH 3-50<br />

WT3400PU 3-50<br />

WT3400PUNH 3-50<br />

WT3800PU 3-50<br />

WT3800PUNH 3-50<br />

WTB11200CU 3-43<br />

WTB11200CUNH 3-43<br />

WTB11600CU 3-43<br />

WXB3700NU 3-25<br />

WXB3800N 3-25<br />

WXB3800NU 3-25<br />

WXB3900N 3-25<br />

WXB3900NU 3-25<br />

WXBM11200N 3-25<br />

WXBM11200NU 3-25<br />

WXBM31200N 3-25<br />

WXBM31200NU 3-25<br />

WXS1400NU 3-40<br />

WPRLK600 3-106, 3-107, 3-108,<br />

3-109, 3-137<br />

WPRLK750 3-106, 3-107, 3-108,<br />

3-109, 3-137<br />

WPSK1000 3-109, 3-137<br />

WPSK400 3-109, 3-137<br />

WPSK600 3-109, 3-137<br />

WPSK800 3-109, 3-137<br />

WPUG14 13-20<br />

WPUG26 13-20<br />

WTB11600CUNH 3-43<br />

WTB12000BU 3-43<br />

WTB12000TU 3-43<br />

WTB12000TUNH 3-43<br />

WTB12400BU 3-43<br />

WTB12400TU 3-43<br />

WTB12400TUNH 3-43<br />

WTB1400CU 3-43<br />

WTB1400CUNH 3-43<br />

WTB1800CU 3-43<br />

WXS1600NU 3-40<br />

WXS1800NU 3-40<br />

WXS3400NU 3-40<br />

WXS3600NU 3-40<br />

WXS3800NU 3-40<br />

XEQH 15-76<br />

XMFMKIT 10-7<br />

xGB1B015B 11-13<br />

xGB1B020B 11-13<br />

xGB1B025B 11-13<br />

WS11200BU 3-34<br />

WS1400CU 3-34<br />

WS1400CUNH 3-34<br />

WS1600CU 3-34<br />

WS1600CUNH 3-34<br />

WS1800CU 3-34<br />

WS1800CUNH 3-34<br />

WS31200BU 3-34<br />

WS3400CU 3-34<br />

WS3400CUNH 3-34<br />

WTB1800CUNH 3-43<br />

WTB31200CU 3-43<br />

WTB31200CUNH 3-43<br />

WTB31600CU 3-43<br />

WTB31600CUNH 3-43<br />

WTB32000BU 3-43<br />

WTB32000TU 3-43<br />

WTB32000TUNH 3-43<br />

WTB32400BU 3-43<br />

WTB32400TU 3-43<br />

xGB1B030B 11-13<br />

xGB1B035B 11-13<br />

xGB1B040B 11-13<br />

xGB1B045B 11-13<br />

xGB1B050B 11-13<br />

xGB1B060B 11-13<br />

xGB1B070B 11-13<br />

xGB1B080B 11-13<br />

xGB1B090B 11-13<br />

xGB1B100B 11-13<br />

WS3600CU 3-34<br />

WS3600CUNH 3-34<br />

WS3800CU 3-34<br />

WS3800CUNH 3-34<br />

WSC150C 2-7<br />

WSC250C 2-7<br />

WSC350C 2-7<br />

WSN251CR 2-7<br />

WSN351CR 2-7<br />

WSN451CR 2-7<br />

WTB32400TUNH 3-43<br />

WTB3400CU 3-43<br />

WTB3400CUNH 3-43<br />

WTB3800CU 3-43<br />

WTB3800CUNH 3-43<br />

WTBN31200CU 3-97<br />

WTBN31200CUNH 3-97<br />

WTBN3400CU 3-97<br />

WTBN3400CUNH 3-97<br />

WTBN3600CU 3-97<br />

xGB1B110B 11-13<br />

xGB1B125B 11-13<br />

xGB2B015B 11-13<br />

xGB2B020B 11-13<br />

xGB2B025B 11-13<br />

xGB2B030B 11-13<br />

xGB2B035B 11-13<br />

xGB2B040B 11-13<br />

xGB2B045B 11-13<br />

xGB2B050B 11-13<br />

WSP1 3-102<br />

WSP3 3-102<br />

WSPD1B10A 3-90<br />

WSPD1B20A 3-90<br />

WSPD1B30A 3-90<br />

WSPD1B40A 3-90<br />

WSPD1B50A 3-90<br />

WSPD1N10A 3-90<br />

WSPD1N20A 3-90<br />

WSPD1N30A 3-90<br />

WTBN3600CUNH 3-97<br />

WTBN3800CU 3-97<br />

WTBN3800CUNH 3-97<br />

WXB11000N 3-25<br />

WXB11000NU 3-25<br />

WXB11200N 3-25<br />

WXB11200NU 3-25<br />

WXB1200N 3-25<br />

WXB1200NU 3-25<br />

WXB1250N 3-25<br />

xGB2B060B 11-13<br />

xGB2B070B 11-13<br />

xGB2B080B 11-13<br />

xGB2B090B 11-13<br />

xGB2B100B 11-13<br />

xGB2B110B 11-13<br />

xGB2B125B 11-13<br />

xGB3B015B 11-13<br />

xGB3B020B 11-13<br />

xGB3B025B 11-13<br />

WSPD1N40A 3-90<br />

WSPD1N50A 3-90<br />

WSPD3B10B 3-90<br />

WSPD3B10C 3-90<br />

WSPD3B20B 3-90<br />

WSPD3B20C 3-90<br />

WSPD3B30B 3-90<br />

WSPD3B30C 3-90<br />

WSPD3B40B 3-90<br />

WSPD3B40C 3-90<br />

WXB1250NU 3-25<br />

WXB1300N 3-25<br />

WXB1300NU 3-25<br />

WXB1350N 3-25<br />

WXB1350NU 3-25<br />

WXB1400N 3-25<br />

WXB1400NU 3-25<br />

WXB1450N 3-25<br />

WXB1450NU 3-25<br />

WXB1500N 3-25<br />

xGB3B030B 11-13<br />

xGB3B035B 11-13<br />

xGB3B040B 11-13<br />

xGB3B045B 11-13<br />

xGB3B050B 11-13<br />

xGB3B060B 11-13<br />

xGB3B070B 11-13<br />

xGB3B080B 11-13<br />

xGB3B090B 11-13<br />

xGB3B100B 11-13<br />

WSPD3B50B 3-90<br />

WSPD3B50C 3-90<br />

WSPD3N10B 3-90<br />

WSPD3N10C 3-90<br />

WSPD3N20B 3-90<br />

WSPD3N20C 3-90<br />

WSPD3N30B 3-90<br />

WSPD3N30C 3-90<br />

WSPD3N40B 3-90<br />

WSPD3N40C 3-90<br />

WXB1500NU 3-25<br />

WXB1600N 3-25<br />

WXB1600NU 3-25<br />

WXB1700N 3-25<br />

WXB1700NU 3-25<br />

WXB1800N 3-25<br />

WXB1800NU 3-25<br />

WXB1900N 3-25<br />

WXB1900NU 3-25<br />

WXB31000N 3-25<br />

xGB3B110B 11-13<br />

xGB3B125B 11-13<br />

WSPD3N50B 3-90<br />

WSPD3N50C 3-90<br />

WSX019 2-25<br />

WT11200PU 3-50<br />

WT11200PUNH 3-50<br />

WT11600PU 3-50<br />

WT11600PUNH 3-50<br />

WT12000PU 3-50<br />

WT12000PUNH 3-50<br />

WT12400PU 3-50<br />

WXB31000NU 3-25<br />

WXB31200N 3-25<br />

WXB31200NU 3-25<br />

WXB3200N 3-25<br />

WXB3200NU 3-25<br />

WXB3250N 3-25<br />

WXB3250NU 3-25<br />

WXB3300N 3-25<br />

WXB3300NU 3-25<br />

WXB3350N 3-25<br />

I-32<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Technical<br />

SPEEDFAX TM<br />

TSection<br />

C o n t e n t s<br />

Types of Power Distribution Systems T-2 – T-4<br />

Ground Fault Protection T-5 – T-10<br />

Overcurrent Protection and Coordination T-11<br />

System Analysis T-12<br />

Current Limiting Circuit Breaker Technology T-13<br />

Series-Connected Combination Ratings T-14<br />

Harmonics / K-factor Ratings T-15 – T-16<br />

Table 1:<br />

Ampacities of Insulated Conductors T-17<br />

Table 2:<br />

Correction Factors for Ambient Temperatures T-17<br />

Table 4A:<br />

Motor Full-Load Currents of<br />

Three Phase AC Induction Type Motors T-18<br />

Table 4B:<br />

Motor Full-Load Currents in Amperes,<br />

Single Phase AC T-18<br />

Table 4C:<br />

Motor Full-Load Currents in Amperes, DC T-18<br />

Table 4D:<br />

Conversion Table of Polyphase Design T-18<br />

Table 5:<br />

Normal-Load and Fault Currents of<br />

Three Phase Transformers T-18<br />

Table 6:<br />

Electrical Formulas for Finding Amperes,<br />

Horsepower Kilowatts, and kVA T-19<br />

Table 7:<br />

Grounding Electrode Conductor for<br />

AC Systems T-19<br />

Table 8:<br />

Minimum Size Grounding Conductors for<br />

Grounding Raceways and Equipment T-19<br />

Capacitor Circuit Conductors T-20<br />

Conversion Table T-21<br />

Scan to connect<br />

online to the<br />

most up-todate<br />

version of<br />

this Section of<br />

SPEEDFAX.<br />

T TECHNICAL<br />

(Section was last modified on 11/14/17)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog T-1


Technical<br />

Types of Power Distribution Systems<br />

Selection<br />

T<br />

TECHNICAL<br />

There are several basic considerations<br />

which must be included by the system<br />

design engineer to select and design the<br />

best power distribution system which will<br />

supply power to both present and future<br />

loads most economically. Among these<br />

are:<br />

b Safety<br />

b Reliability<br />

b Maintenance<br />

b Flexibility<br />

b Voltage Regulation<br />

b Initial Investment<br />

b Simplicity of Operation<br />

The characteristics of electrical service<br />

available at the building site, the types of<br />

loads, the quality of service required, and<br />

the size and configuration of building are<br />

also important factors that will influence<br />

system design and circuit arrangement.<br />

Four basic circuit arrangements are used<br />

for the distribution of electric power. They<br />

are the radial, primary selective, secondary<br />

selective, and secondary network circuit<br />

arrangements. The following discussion of<br />

these circuit arrangements covers both<br />

the high-voltage and low-voltage circuits.<br />

The reader should recognize that the highvoltage<br />

circuits and substations may be<br />

owned by either the utility company or the<br />

building owner, depending upon the<br />

electric rates, the practice, and<br />

requirements of the particular electric<br />

utility serving the specific building site.<br />

Radial System<br />

If power is brought into a building at<br />

utilization voltage, the simplest and the<br />

lowest cost means of distributing the<br />

power is to use a radial circuit<br />

arrangement. The radial system is the<br />

simplest that can be used, and has the<br />

lowest system investment. It is suitable for<br />

smaller installations where continuity of<br />

service is not critical.<br />

The low voltage service entrance circuit<br />

comes into the building through service<br />

entrance equipment and terminates at a<br />

main switchgear assembly, switchboard or<br />

panelboard. Feeder circuits are pro vided to<br />

the loads or to other subswitchboards,<br />

distribution cabinets, or panelboards.<br />

Figure 1 shows the two forms of radial<br />

circuit arrangements most frequently<br />

used. Under normal operating conditions,<br />

the entire load is served through the<br />

single incoming supply circuit, and in the<br />

case of high voltage service, through the<br />

transformer. A fault in the supply circuit,<br />

the transformer, or the main bus will<br />

cause an interruption of service to all<br />

loads. A fault on one of the feeder or<br />

branch circuits should be iso lated from the<br />

rest of the system by the circuit protective<br />

device on that circuit. Under this<br />

condition, continuity of service is<br />

maintained for all loads except those<br />

served from the faulted circuit.<br />

The need for continuity of service often<br />

requires multiple paths of power supply as<br />

opposed to the single path of power<br />

supply in the radial system.<br />

Figure 2. Expanded Radial System—Single<br />

Primary Feeder<br />

A fault in a primary feeder in the<br />

arrangement shown in Figure 2 will cause<br />

the main protective device to operate and<br />

interrupt service to all loads. If the fault<br />

were in a transformer, service could be<br />

restored to all loads except those served<br />

from that transformer. If the fault were in<br />

a primary feeder, service could not be<br />

restored to any loads until the source of<br />

trouble had been eliminated. Since it is to<br />

be expected that more faults will occur on<br />

the feeders than in the transformers, it<br />

becomes logical to consider providing<br />

individual circuit protection on the pri mary<br />

feeders as shown in Figure 3. This<br />

arrangement has the advantage of<br />

Figure 3. Expanded Radial Systems<br />

individual Primary Feeder Protection<br />

making it possible to limit outages due to<br />

a feeder or transformer fault to the loads<br />

associated with the faulted equipment. If<br />

circuit breakers are used for primary<br />

feeder protection, the cost of this system<br />

will be high. Even if fused switches are<br />

used, the cost of the arrangement of<br />

Figure 3 will exceed the cost of the<br />

arrangement of Figure 2.<br />

Primary Selective System<br />

The circuit arrangement of Figure 4<br />

provides means of reducing both the<br />

extent and duration of an outage caused<br />

by a primary feeder fault. This operating<br />

feature is provided through the use of<br />

duplicate primary feeder circuits and load<br />

interrupter switches that permit<br />

connection of each secondary substation<br />

transformer to either of the two primary<br />

feeder circuits. Each primary feeder circuit<br />

must have sufficient capacity to carry the<br />

total load in the building.<br />

Figure 4. Primary Selective Systems<br />

Figure 1. Radial Systems<br />

T-2<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Technical<br />

Types of Power Distribution Systems<br />

Selection<br />

Under normal operating conditions, the<br />

appropriate switches are closed in an<br />

attempt to divide the load equally<br />

between the two primary feeder circuits.<br />

Then, should a primary feeder fault occur,<br />

there is an interruption of service to only<br />

half of the load. Service can be restored to<br />

all loads by switching the deenergized<br />

transformers to the other primary feeder<br />

circuit. The primary selective switches are<br />

usually manually oper ated and outage<br />

time for half the load is determined by the<br />

time it takes to accomplish the necessary<br />

switching. An automatic throwover<br />

switching arrangement could be used to<br />

avoid the interruption of service to half the<br />

load. However, the additional cost of the<br />

automatic feature may not be justified in<br />

many applications. If a fault occurs in a<br />

secondary substation transformer, service<br />

can be restored to all loads except those<br />

served from the faulted transformer.<br />

The higher degree of service continuity<br />

afforded by the primary selective<br />

arrangement is realized at a cost<br />

somewhat higher than a simple radial<br />

system due to the extra primary cables<br />

and switchgear.<br />

Secondary Selective System<br />

Under normal conditions, the secondary<br />

selective arrangement of Figure 5 is<br />

operated as two separate radial systems.<br />

The secondary tie circuit breaker in each<br />

secondary substation is normally open.<br />

The load served from a secondary<br />

selective substation should be divided<br />

equally between the two bus sections. If a<br />

fault occurs on a primary feeder or in a<br />

transformer, service is interrupted to all<br />

loads associated with the faulted feeder or<br />

transformer. Service may be restored to all<br />

secondary buses by first opening the main<br />

secondary switch or circuit breaker<br />

associated with the faulted transformer<br />

and primary feeder, and then closing the<br />

tie breaker. The two transformer<br />

secondary circuit breakers in each<br />

substation should be interlocked with the<br />

secondary tie breaker in such a manner<br />

that all three cannot be in the closed<br />

position simultaneously. This prevents<br />

parallel operation of the two transformers<br />

and thereby minimizes the interrupting<br />

duty imposed on the secondary switching<br />

devices. It also eliminates the possibility of<br />

interrupting service to all loads on the bus<br />

when a fault occurs in either a pri mary<br />

feeder or a transformer.<br />

The cost of the secondary selective<br />

system will depend upon the spare<br />

capacity in the transformers and primary<br />

feeders. The minimum transformer and<br />

primary feeder capacity will be determined<br />

Figure 5. Secondary Selective System<br />

Using Close-Coupled Double-Ended<br />

Substation<br />

by essential loads that must be served<br />

under emergency operating conditions. If<br />

service is to be provided for all loads<br />

under emergency conditions, then each<br />

primary feeder should have sufficient<br />

capacity to carry the total load, and each<br />

transformer should be capable of carrying<br />

the total load in each substation.<br />

This type of system will be more<br />

expensive than either the radial or primary<br />

selective system, but it makes restoration<br />

of service to all essential loads possible in<br />

the event of either a primary feeder or<br />

transformer fault. The higher cost results<br />

from the duplication of transformer<br />

capacity in each secondary substation.<br />

This cost may be reduced by shedding<br />

nonessential loads.<br />

A modification of the secondary selective<br />

circuit arrangement is shown in Figure 6.<br />

In this arrangement there is only one<br />

transformer in each secondary substation,<br />

but adjacent substations are<br />

interconnected in pairs by a normally open<br />

low voltage tie circuit. When the primary<br />

feeder or transformer supplying one<br />

secondary substation bus is out of service,<br />

the essential loads on that substation bus<br />

can be supplied over the tie circuit. The<br />

operating aspects of this system are<br />

somewhat complicated if the two<br />

substations are separated by distance.<br />

The best arrangement is to use closecoupled,<br />

double-ended substations.<br />

Secondary Network System<br />

Many buildings with radial distribution<br />

systems are served at utilization voltage<br />

from utility secondary network systems.<br />

The network supply system assures a<br />

relatively high degree of service reliability.<br />

The utility network may take the form of a<br />

Figure 6. Secondary Selective System<br />

Using Two Single-Ended Substations<br />

With Cable or Bus Tie<br />

distributed network or a spot network. If<br />

the building demand is in the order of 750<br />

kVA or higher, a spot network will often be<br />

established to serve the building. In<br />

buildings where a high degree of service<br />

reliability is required, and where spot<br />

network supply may not be available, the<br />

distributed secondary network system is<br />

often used. This is particularly true of<br />

institutional buildings such as hospitals.<br />

The network may take the form of several<br />

secondary substations interconnected by<br />

low voltage circuits. However, the most<br />

common practice is to use some form of<br />

the spot network circuit arrangement.<br />

Figure 7. Simple Spot Network System<br />

A simple spot network, such as shown in<br />

Figure 7, consists of two or more identical<br />

transformers supplied over separate<br />

primary feeder circuits. The transformers<br />

are connected to a common low voltage<br />

T TECHNICAL<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog T-3


Technical<br />

Types of Power Distribution Systems<br />

Selection<br />

T<br />

TECHNICAL<br />

bus through network protectors and are<br />

operated in parallel. A network protector<br />

is an electrically operated power circuit<br />

breaker controlled by network relays in<br />

such a way that the circuit breaker<br />

automatically opens when power flows<br />

from the low voltage bus toward the<br />

transformer. When voltages in the<br />

system are such that power would flow<br />

toward the low voltage bus from the<br />

transformer, it will close automatically.<br />

Network protectors are normally<br />

equipped with relays which operate for<br />

faults in the network transformer or high<br />

voltage feeder only. The network is often<br />

operated on the assumption that<br />

network failure will “burn” open.<br />

Network protectors without<br />

supplementary protection do not meet<br />

the requirements of the NEC for<br />

overcurrent, ground fault, or short circuit<br />

protection. Protection of the network or<br />

collector bus may be added by providing<br />

sensing devices, including ground fault<br />

detection, with tripping of the network<br />

protectors. The most common use of the<br />

network protector, however, has been by<br />

utilities in vaults where failure of the<br />

network devices could cause damage<br />

limited to the vault. High integrity design<br />

involving wide phase separation and the<br />

use of “catastrophe” fusing minimize the<br />

danger and extent of a network failure. A<br />

conventional circuit breaker with time<br />

overcurrent and instantaneous trip<br />

devices plus network relays can meet<br />

the NEC requirements. However, the full<br />

reliability of the network may be<br />

compromised since selectivity between<br />

these devices is difficult to obtain.<br />

Under normal operating conditions, the<br />

total load connected to the bus is shared<br />

equally by the transformers. Should a<br />

fault occur in a transformer or on a primary<br />

feeder, the network protector<br />

associated with the faulted transformer<br />

or feeder will open on reverse power<br />

flow to isolate the fault from the low<br />

voltage bus. The remaining transformer<br />

or transformers in the substation will<br />

continue to carry the load and there will<br />

be no interruption of service to the loads,<br />

except for a voltage dip during the time<br />

that it takes for the protective equipment<br />

to operate.<br />

If only two transformers are used in a<br />

spot network substation, each<br />

transformer must be capable of carrying<br />

the total load served from the low<br />

voltage bus. The amount of spare<br />

transformer capacity in the substation<br />

can be reduced by using a primary<br />

selective switching arrangement with<br />

each transformer, or by using three or<br />

more transformers. If the primary<br />

selective switching arrangement is used,<br />

the total load can be about 160 percent<br />

of the nameplate rating of one of the<br />

transformers. This produces an overload<br />

on one transformer until such time as<br />

the remaining transformer can be<br />

switched to the other feeder in the case<br />

of a primary feeder fault.<br />

The interrupting duty imposed on the<br />

low voltage protective devices in a spot<br />

network substation is higher than in<br />

radial, primary selective, or secondary<br />

selective substations having the same<br />

load capability because of the spare<br />

transformer capacity required in the spot<br />

network substation and because the<br />

transformers are operated in parallel.<br />

Figure 8. Secondary Network System<br />

The spare transformer capacity, the<br />

network protectors, and the higher<br />

interrupting duty will make the secondary<br />

network arrangement much more<br />

expensive than the other arrangements.<br />

At the same time, these elements make<br />

the reliability of the network system<br />

greater than for the other system<br />

configurations.<br />

The secondary network may also<br />

take the form shown in Figure 8.<br />

In this arrangement there is only<br />

one transformer in each secondary<br />

substation, and the substations are<br />

interconnected by normally closed<br />

low voltage tie circuits. The tie circuits<br />

permit interchange of power between<br />

substations to accommodate unequal<br />

loading on the sub stations and to provide<br />

multiple paths of power flow to the<br />

Figure 9. Primary Selective Secondary<br />

Network System<br />

various load buses. In normal operation,<br />

the substations are about equally loaded<br />

and the current flowing in the tie circuits<br />

is relatively small. However, if a network<br />

protector opens to isolate a transformer<br />

on a primary feeder fault, the load on the<br />

associated bus is then carried by the<br />

adjacent network units and is supplied<br />

over the tie circuits. This arrangement<br />

provides for continuous power supply to<br />

all low voltage load buses, even though a<br />

primary feeder circuit or a transformer is<br />

taken out of service.<br />

In the network arrangement in Figure 9,<br />

if there were three incoming primary<br />

feeder circuits and three transformers,<br />

the combined capacity of two of the<br />

transformers should be sufficient to carry<br />

the entire load on the three substations<br />

on the basis that only one feeder is out<br />

of service at one time. Generally, these<br />

transformers would all have the same<br />

ratings. With this arrangement, as with<br />

the spot network arrangement, a<br />

reduction in spare transformer capacity<br />

can be achieved, if a primary selective<br />

switching arrangement is used at each<br />

substation transformer. However, if three<br />

or more primary feeder circuits are<br />

available, the reduction in transformer<br />

capacity achieved through the use of a<br />

primary selective arrangement may be<br />

small.<br />

Cable ties or busway ties, as shown in<br />

Figures 8 and 9, will require careful<br />

consideration of load distribution during<br />

contingencies and of the safety aspects<br />

with regard to backfeeds. Key or other<br />

mechanical interlocking of switches or<br />

circuit breakers may be essential.<br />

T-4<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Technical<br />

Ground Fault Protection<br />

Selection<br />

The term “low magnitude” arcing ground<br />

fault is a deceptive description of this<br />

type fault. What is meant by this is<br />

that the fault current magnitude is low<br />

compared to that of a bolted fault. Even<br />

so, the arc energy released at the point<br />

of the fault can cause much damage and<br />

may result in a fire. A ground fault is an<br />

insulation failure between an energized<br />

conductor and ground. A phase-to-ground<br />

arcing fault, unlike a phase-to-phase<br />

bolted fault, is a high-impedance type<br />

fault. The factors that contribute to this<br />

high impedance are the resistance of the<br />

arc and the impedance of the return path.<br />

This return path is usually metal conduit,<br />

raceway, busway housing or switchboard<br />

frames. Another contributing factor is the<br />

spasmodic nature of the arc. The circuit<br />

breaker or fuse protecting the circuit<br />

detects the fault current, but the actual<br />

ground fault current magnitude is ever<br />

changing due to arc elongating blowout<br />

effects, self-clearing attempts and arc<br />

reignition.<br />

These current limiting effects make the<br />

circuit breaker or fuse incapable of<br />

detecting the actual damage that is<br />

occurring. This is not to imply that these<br />

devices are inadequate. The problem is<br />

one of system protection because the<br />

circuit breaker must be adjusted (or fuse<br />

size selected) so as to hold without<br />

tripping under momentary overload<br />

conditions, such as motor starting current<br />

or transformer inrush current. Therefore,<br />

the circuit breaker or fuse cannot open<br />

quickly enough under relatively low<br />

magnitude faults to limit the arcing<br />

damage.<br />

Figure 10 illustrates the basic problem.<br />

Shown is a typical distribution system<br />

with a 1600 ampere main service<br />

entrance unit with a circuit breaker<br />

(single line “a”) or fused service<br />

protector (single line “b”). A ground fault<br />

of 1500 amperes on the bus would affect<br />

but would not open either device. A 4000<br />

ampere ground fault would be cleared in<br />

approximately 35 seconds by the circuit<br />

breaker and in 230 seconds by the fuse.<br />

To allow a fault of this magnitude to<br />

persist for this length of time would<br />

create more than 92,000 kW seconds of<br />

arc energy. As a result of tests made, it<br />

has been determined that an arc with a<br />

value of 1050 kW seconds of energy<br />

would vaporize about 1.0 cubic in. of<br />

copper or 2.5 cubic in. of aluminum.<br />

Obviously a fault of the magnitude<br />

shown in Figure 10 could cause a<br />

considerable amount of damage.<br />

The nature of low-level arcing ground<br />

faults makes impractical their detection<br />

Figure 10. Ground Fault Protection<br />

by a traditional overcurrent devices. To<br />

complete total protection of the system<br />

against all possible types of faults, other<br />

means are utilized to detect ground fault<br />

currents, including:<br />

b Zero sequence method<br />

b Source ground current (or ground<br />

return) method<br />

b Residual connection method<br />

Zero Sequence Method<br />

This is commonly used when ground<br />

fault protection is provided for equipment<br />

employing electromechanical trip<br />

devices. The scheme uses a core balance<br />

type current transformer (ground sensor)<br />

which encircles all phase conductors (and<br />

neutral on four wire system) to detect<br />

ground faults.<br />

The operation of this system is such that<br />

under normal operating conditions (eg.,<br />

no ground fault on the system) there is<br />

no output from the ground sensor to the<br />

tripping relay because the vector sum of<br />

all the currents through the sensor<br />

window is zero.<br />

(I a + l b + I c + I n = 0)<br />

If a ground fault occurs on the system,<br />

there is now an additional current (I g )<br />

seen by ground sensor which returns to<br />

the source by a path other than through<br />

the sensor window. The sensor now<br />

sees an unbalance caused by Ig and<br />

operates the ground relay which trips the<br />

circuit protector.<br />

(I a + l b + l c + I n = I g )<br />

The ground sensor is located<br />

downstream from the point at which the<br />

system is grounded and can be mounted<br />

either on the line side or load side of the<br />

main disconnect device. This method can<br />

be used on incoming main disconnect or<br />

on feeders.<br />

T TECHNICAL<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog T-5


Technical<br />

Ground Fault Protection<br />

Selection<br />

Source Ground Current (or Ground<br />

Return) Method<br />

This method of detecting the ground<br />

fault current Ig locates the ground<br />

sensor on the neutral connection to<br />

ground at the service entrance. This<br />

means that the ground sensor only<br />

detects ground fault current. This type of<br />

detection has some limitations because<br />

it is detecting the ground fault return<br />

current. On multiple source systems<br />

with multiple connections to ground, this<br />

ground fault current can return by more<br />

than one path, therefore, some<br />

sensitivity in detecting these faults<br />

would be lost.<br />

Residual Connection Method<br />

Current sensors, one on each of the<br />

phase conductors and on the neutral<br />

conductors, are connected in common.<br />

This common (or residual connection)<br />

measures the vector summation of the<br />

phase currents and the neutral current.<br />

Under normal conditions, this vector<br />

summation will be zero, and no current<br />

will be applied to the ground relay.<br />

If a fault involving ground occurs, the<br />

current summation is not equal to zero.<br />

Current flows into common connection<br />

which is applied to the relay. This<br />

method of detecting ground fault current<br />

is used in circuit breakers with electronic<br />

trip device.<br />

Figure 11. Schematic for Zero Sequence<br />

Figure 12. Schematic for Source Ground Current<br />

GFS = Ground Fault Sensor<br />

GFP = Ground Fault Protection<br />

(Relay or Trip Unit)<br />

T<br />

TECHNICAL<br />

Residual Ground Current<br />

Sensing<br />

3-Wire System<br />

This system is used with electronic trip<br />

units, and always includes three current<br />

sensors mounted on the circuit breaker.<br />

A trip element is connected in series<br />

with each sensor to provide phase<br />

overcurrent protection. By adding a<br />

ground trip element in the residual<br />

(neutral) circuit of the three current<br />

sensors, it will sense ground fault current<br />

only, and not load current. This permits<br />

more sensitive settings to protect<br />

against low magnitude ground faults.<br />

This scheme is shown in Figure 14.<br />

Under normal conditions, the vector sum<br />

of the current in all of the phases equals<br />

zero. No current would flow in the GND<br />

element, which is also true under the<br />

condition of a phase-to-phase fault.<br />

A phase-to-ground fault would cause a<br />

current to flow in the GND trip element.<br />

If the magnitude of this current exceeds<br />

the pickup setting for the required time,<br />

the trip unit will operate to trip the<br />

breaker.<br />

Figure 13. Schematic for Residual Method<br />

Figure 14. Schematic for Ground Protection on 3-Wire Systems, Residual Sensing<br />

T-6<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Technical<br />

Ground Fault Protection<br />

4-Wire System<br />

To avoid false tripping, a fourth current<br />

sensor is connected in the neutral<br />

conductor to sense normal neutral<br />

current. This fourth sensor is connected<br />

so that it cancels the normal neutral<br />

current which is developed in the residual<br />

circuit as shown in Figure 15.<br />

Under normal conditions, the vector sum<br />

of the current in all phases equals the<br />

neutral current. Disregarding the effects<br />

of the neutral sensor connection, the<br />

neutral current would flow through the<br />

GND element. Since this is normal<br />

neutral current, pickup of the GND<br />

element is not desired. Therefore, the<br />

neutral sensor is added to sense the<br />

same neutral current as the GND sensor<br />

— but opposite in polarity. The result is a<br />

circulating current between the phase<br />

sensing current sensors and the neutral<br />

sensor, with no current flowing through<br />

the GND sensor. This is similar to a<br />

differential relay circuit. When a phase-toground<br />

fault occurs, the vector sum of<br />

the phase currents will no longer equal<br />

the neutral current because the ground<br />

Figure 15. Schematic for Ground Protection on 4-Wire Systems, Residual Sensing<br />

fault current returns via the ground bus<br />

and bypasses the neutral. If the<br />

magnitude of the phase-to-ground<br />

Selection<br />

current exceeds the pickup setting of the<br />

GND element for the required time, the<br />

trip unit will operate to open the breaker.<br />

Types Of Coordinated Ground Fault Tripping Systems<br />

There are two types of Coordinated<br />

Ground Fault Systems:<br />

b Time / Current Selective<br />

b Zone Selective (Zone Interlock)<br />

Time / Current Selective<br />

In this system the time / current<br />

characteristics of the Ground Fault<br />

Protection (GFP) devices used with each<br />

disconnect are coordinated so that the<br />

nearest disconnect supplying the ground<br />

fault location will open. Any upstream<br />

disconnects remain closed and continue<br />

to supply the remaining load current. Each<br />

set of GFP devices should have a<br />

specified time-current operating<br />

characteristic. When disconnects are<br />

connected in series, each downstream<br />

device should use a time-current setting<br />

that will cause it to open and clear the<br />

circuit before any upstream disconnect<br />

tripping mechanism is actuated. The timecurrent<br />

bands of disconnects in series<br />

must not overlap and must be separated<br />

from each other sufficiently to allow for<br />

the clearing time of each disconnecting<br />

means used. The time / current selective<br />

system is recommended for applications<br />

where damage levels associated with the<br />

time / current settings used are tolerable.<br />

This type of system does not require<br />

interlocking wiring between the GFP<br />

devices associated with main feeder and<br />

branch disconnecting devices.<br />

Figure 16, on the next page, illustrates<br />

time / current selective coordination in a<br />

system involving a 4000 ampere main<br />

circuit breaker and a 1600 ampere feeder<br />

circuit breaker in an incoming service<br />

switchboard. These feed a distribution<br />

switchboard with a 600 ampere subfeeder<br />

to a 100 ampere branch breaker.<br />

The system is coordinated so that only<br />

the circuit breaker nearest the location of<br />

the ground fault trips.<br />

Zone Selective (Zone Interlock)<br />

In this system each disconnecting means<br />

should open as quickly as possible when<br />

a ground fault occurs in the zone where<br />

this disconnect is the nearest supply<br />

source.<br />

The GFP device for an upstream<br />

disconnecting means should have at least<br />

two modes of operation. If a ground fault<br />

occurs between it and the nearest<br />

downstream disconnect, it should operate<br />

in its fast tripping mode.<br />

When a ground fault occurs beyond the<br />

downstream disconnect, the downstream<br />

GFP device should open in its fast<br />

tripping mode and simultaneously<br />

send a restraining signal to the upstream<br />

device and transfer that device to a timedelay<br />

tripping mode. The upstream timedelay<br />

tripping characteristic selected<br />

should be such that the downstream<br />

disconnect will open and clear the circuit<br />

before the upstream disconnect tripping<br />

mechanism is actuated. The time-current<br />

characteristic of the upstream device<br />

should be such as to offer backup<br />

protection in the event of malfunction of<br />

the downstream equipment.<br />

Alternatively, a restraining signal from a<br />

downstream device may be used to<br />

prevent the tripping of an upstream<br />

disconnect on ground fault instead of<br />

causing it to operate in the time-delay<br />

tripping mode. This may be done where<br />

backup protection is less important than<br />

continuity of service to critical loads<br />

supplied by the upstream unit. There are<br />

very few instances in which this is<br />

justified, and a careful study of the entire<br />

system should be made before using this<br />

type of interlocking.<br />

For a zone selective system, the timecurrent<br />

bands of disconnects in series,<br />

although used only for backup protection,<br />

should not overlap and should be<br />

separate from each other sufficiently to<br />

allow for the opening time of each<br />

disconnecting means used.<br />

T TECHNICAL<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog T-7


Technical<br />

Ground Fault Protection<br />

Selection<br />

Time/Current Selective Ground Coordination<br />

Figure 17. Zone Interlocking Scheme<br />

T<br />

Figure 16. Fully Coordinated Multizone GFP System<br />

The zone selective or zone interlock<br />

system provides fast tripping of the<br />

nearest disconnect upstream of the<br />

ground fault. The damage level is the<br />

lowest that is possible because the<br />

ground fault is cleared as quickly as the<br />

protective equipment can respond and<br />

the disconnect can open. Additional<br />

interlocking wiring and circuity for<br />

sending and receiving the restraining<br />

signals are required.<br />

The zone selective or zone interlock<br />

scheme is for those few special<br />

applications where exceptionally fast<br />

tripping is necessary for all feeders<br />

throughout the entire system to reduce<br />

damage. Note that although the relay<br />

time can be reduced appreciably, the<br />

circuit breaker mechanism and arcing<br />

time (plus safety margin) will still be<br />

present.<br />

Zone Selective Operation (Figure 17):<br />

a) Relay-1 will sense a ground fault at<br />

A when it exceeds 10 amperes. It<br />

will instantly initiate tripping of the<br />

Branch breaker and send restraining<br />

signals (transfer from instantaneous<br />

operation to time-delayed operation)<br />

to Relay-2 and Relay-3 (Relay-2 and<br />

Relay-3 will then back up Relay-1 on<br />

a time coordinated basis). Relay-4<br />

will be restrained by Relay-2 if<br />

ground fault exceeds 100 amperes.<br />

b) Relay-2 will sense a ground fault at<br />

B when it exceeds 100 amperes. It<br />

will instantly initiate tripping of the<br />

Sub-Feeder breaker and send<br />

restraining signals to Relay-3 and<br />

Relay-4.<br />

c) Relay-3 will sense a ground fault at<br />

C when it exceeds 400 amperes. It<br />

will instantly initiate tripping of the<br />

Feeder breaker and send a<br />

restraining signal to Relay-4.<br />

d) Relay-4 will sense a ground fault at<br />

D when it exceeds 800 amperes. It<br />

will instantly initiate tripping of the<br />

Main breaker.<br />

TECHNICAL<br />

T-8<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Technical<br />

Ground Fault Protection<br />

Typical Application Diagrams<br />

Figures 18 through 23 on this and the<br />

facing page show the basic methods of<br />

applying ground fault protection (GFP).<br />

Other types of distribution systems will<br />

require variations of these methods to<br />

satisfy other system conditions.<br />

These diagrams show circuit breakers as<br />

the disconnects. Any disconnecting<br />

means can be utilized, providing it is<br />

suitable for use with a ground fault<br />

protection system as indicated in the<br />

scope of this application guide. The<br />

examples do not show protection against<br />

a ground fault on the supply side of the<br />

main disconnect.<br />

Sensing device and disconnect locations<br />

define zones of protection. Source side<br />

Selection<br />

and ground return sensors provide<br />

protection only on the load side of associated<br />

disconnects. If a vector summation<br />

method is used and its sensors are<br />

located on load side of a disconnect, the<br />

zone between a source and actual sensor<br />

location becomes the responsibility of<br />

the next upstream protective device.<br />

Table 17.2 Recommendations for Figures 18-23<br />

Ground<br />

Fault<br />

Protection Figure Sensing Method<br />

On Main<br />

Disconnect Only<br />

On Main and<br />

Feeder<br />

Disconnects<br />

On Main, Feeder,<br />

and Selected<br />

Branch<br />

Disconnects with<br />

Zone Selective<br />

Interlocking<br />

Double-Ended<br />

System with<br />

Protection on<br />

Main and On Tie<br />

and Feeder<br />

Disconnects<br />

18 Vector<br />

Summation<br />

19<br />

Ground Return<br />

20<br />

21<br />

22<br />

23<br />

Main and Feeders–<br />

Vector Summation<br />

Main – Ground Return<br />

Feeders – Vector<br />

Summation<br />

Main and feeders 1-3 –<br />

Vector Summation<br />

MCC branch feeder A –<br />

Zero Sequence<br />

Main and Tie – Ground<br />

Return<br />

Feeders – Vector<br />

Summation<br />

Additional<br />

Ground<br />

Points<br />

Must not be downstream.<br />

May be upstream<br />

None<br />

Must not be downstream of<br />

main ground fault sensor.<br />

May be upstream.<br />

None<br />

Must not be downstream of<br />

main ground fault sensor.<br />

May be upstream.<br />

None<br />

Recommended<br />

Use<br />

Minimum protection only per<br />

Section 230-95 for the<br />

National Electric Code<br />

Improved service continuity<br />

is required<br />

Improved service continuity<br />

and minimum arcing fault<br />

damage are required and<br />

protection is needed on<br />

branch circuits.<br />

Double-ended systems with<br />

ground fault protection on<br />

tie disconnect where<br />

maximum continuity of<br />

service is essential.<br />

Selectivity<br />

Limited selectivity depends<br />

on location of fault and rating<br />

of overcurrent devices on the<br />

upstream side of fault.<br />

Main will allow feeder to trip<br />

for faults downstream of<br />

feeder sensors, but main will<br />

trip if feeder fails to operate.<br />

Main and feeder 1-3 will<br />

provide delayed backup<br />

protection if fault is<br />

downstream of MCC branch<br />

feeder A. Main will provide<br />

delayed backup protection if<br />

fault is downstream of sensors<br />

for feeders 1-3. Main will trip<br />

on fastest curve if fault is<br />

upstream of sensors for<br />

feeders 1-3.<br />

When operating with tie<br />

disconnect open, main will<br />

provide delayed backup<br />

protection if fault is<br />

downstream from feeder<br />

sensors. When operating<br />

with the tie disconnect<br />

closed, the tie will trip before<br />

the main, thus sectionalizing<br />

the bus.<br />

Ground Fault Protection on Main Disconnects Only<br />

Figure 18 Figure 19<br />

T TECHNICAL<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog T-9


Technical<br />

Ground Fault Protection<br />

Selection<br />

Ground Fault Protection on Main and Feeder Disconnects<br />

Figure 20 Figure 21<br />

Ground Fault Protection on Main, Feeder and Selected<br />

Branch Disconnects with Zone Selective Interlocking<br />

Double-Ended System with Ground Fault Protection on<br />

Main and on Tie and Feeder Disconnects<br />

Note: Interlocking<br />

Supplementary interlocking is<br />

required but will vary depending<br />

on equipment used.<br />

Figure 22<br />

Figure 23<br />

TECHNICAL<br />

T<br />

T-10<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Technical<br />

Overcurrent Protection and Coordination<br />

Selection<br />

Coordination of a power distribution<br />

system requires that circuit protective<br />

devices be selected and set so that<br />

electrical disturbances, such as over-loads<br />

or short circuits, will be cleared promptly<br />

by isolating the faulted equipment with<br />

minimum service disruption of the<br />

distribution system. Time / Current<br />

Characteristic Curves are available for<br />

circuit protective devices, such as circuit<br />

breakers and fuses, which show how<br />

quickly they will operate at various values<br />

of overload and short circuit current.<br />

Coordination can be obtained by<br />

comparing these curves for each device in<br />

series in the system.<br />

In developing the system, it will be noted<br />

that many compromises must be made<br />

between the various objectives:<br />

1. System reliability.<br />

2. Continuity of service.<br />

3. Equipment and system protection.<br />

4. Coordination of protective devices.<br />

5. System cost.<br />

Preliminary steps in Coordination study:<br />

A) One-line diagram: used as a base on<br />

which to record pertinent data and<br />

information regarding relays, circuit<br />

breakers, fuses, current transformers, and<br />

operating equipment while at the same<br />

time, providing a convenient<br />

representation of the relationship of circuit<br />

protective devices with one another.<br />

B) Short-circuit study: record all applicable<br />

impedances and ratings; using these<br />

values, a short-circuit study is made to<br />

determine currents available at any<br />

particular point in the system.<br />

C) Determine maximum load currents<br />

which will exist under normal operating<br />

conditions in each of the power-system<br />

circuits, the transformer magnetizing<br />

inrush currents, and times, and the<br />

starting currents, and accelerating times of<br />

large motors. These values will determine<br />

the maximum currents which circuit<br />

protective devices must carry without<br />

operating. The upper boundary of current<br />

sensitivity will be determined by the<br />

smallest values resulting from the<br />

following considerations:<br />

1) Maximum available short-circuit<br />

current obtained by calculation.<br />

2) Requirements of applicable codes<br />

and standards for the protection of<br />

equipment such as cable, motors,<br />

and transformers.<br />

3) Thermal and mechanical limitations<br />

of equipment.<br />

D) Time / current characteristic curves of<br />

all the protective devices to be coordinated<br />

must be obtained. These should be<br />

plotted on standard log-log coordination<br />

paper to facilitate the coordination study.<br />

Mechanics Of Achieving Coordination:<br />

The process of achieving coordination<br />

among protective devices in series is<br />

essentially one of selecting individual units<br />

to match particular circuit or equipment<br />

protection requirements, and of plotting<br />

the time/current characteristic curves of<br />

these devices on a single overlay sheet of<br />

log-log coordination paper.<br />

The achievement of coordination is a trialand-error<br />

routine in which the various<br />

time / current characteristic curves of the<br />

series array of devices are matched one<br />

against another on the graph plot.<br />

When selecting protective devices one<br />

must recognize ANSI and NEC<br />

requirements and adhere to the limiting<br />

factors of coordination such as load<br />

current, short-circuit current, and motor<br />

starting. The protective devices selected<br />

must operate within these boundaries<br />

while providing selective coordination<br />

Figure 24. Coordination of Example System<br />

where possible. Selective coordination is<br />

usually obtained in low voltage systems<br />

when the log-log plot of time / current<br />

characteristics displays a clear space<br />

between the characteristics of the<br />

protective devices operating in series,<br />

that is, no overlap should exist between<br />

any two time/current characteristics if<br />

full selective coordination is to be<br />

obtained. Allow ance must be made for<br />

relay overtravel and for relay and fuse<br />

curve accuracy. Quite often the<br />

coordination study will stop at a point<br />

short of complete selective coordination<br />

because a compromise must be made<br />

between the competing objectives of<br />

maximum protection and maximum<br />

service continuity.<br />

Computer Aided Coordination:<br />

The philosophy discussed above applies<br />

to the “classical” practice of performing<br />

coordination studies manually. Today,<br />

however, there are numerous personal<br />

computer software programs available<br />

for performing coordination studies.<br />

T TECHNICAL<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog T-11


Technical<br />

System Analysis<br />

Selection<br />

T<br />

General<br />

Proper system design requires that the<br />

system be coordinated so the interrupting<br />

capacity and / or short circuit withstand<br />

capabilities of the various components in<br />

the system are not exceeded for any<br />

operating situation. Good practice also<br />

requires that the system be selective, that<br />

is, that the minimum portion of the<br />

system be inter rupted on occurrence of a<br />

fault. The need for selectivity must always<br />

be balanced against the requirements of<br />

economics and coordination with the<br />

overall process needs.<br />

At the conceptual phase of a project,<br />

several distribution system alternatives<br />

should be considered, and examined both<br />

technically and economically. This study<br />

should include sufficient detail for a<br />

thorough understanding of the system<br />

alternatives. The conceptual study should<br />

determine the optimal distribution system<br />

configuration for the project, on which<br />

definitive design can proceed.<br />

At all stages of design, the principal<br />

objectives of personnel safety, equipment<br />

protection, process continuity, fault<br />

clearing, and service continuity should be<br />

considered.<br />

In designing a new or modified<br />

distribution system, the following types of<br />

system studies may be needed:<br />

1. Short Circuit Studies: three phase,<br />

line-to-line, and line-to-ground faults<br />

can be calculated for both close-andlatch<br />

and interrupting conditions,<br />

necessary for checking interrupting<br />

device and related equipment ratings,<br />

and setting protective devices.<br />

2. Circuit Breaker Application Studies:<br />

consider the AC and DC decrements<br />

in the fault current, and the speed of<br />

the various medium voltage circuit<br />

breakers, to determine close-and-latch<br />

and interrupting duties.<br />

3. Protective Device Coordination<br />

Studies: determine characteristics<br />

and settings of protective devices,<br />

e.g., relays, trip devices, fuses, etc.<br />

The coordination study should provide<br />

a balance between protection of<br />

system equipment and continuity<br />

of service.<br />

4. Load Flow Studies: calculate voltages,<br />

phase angles, real and reactive<br />

power, line and transformer loadings<br />

under simulated conditions to aid in<br />

determining the performance of a<br />

new or revamped system during the<br />

planning stage.<br />

5. Motor Starting Studies: determine<br />

severity of voltage dips and adequacy<br />

of load accelerating torque when starting<br />

large motors on a weak system.<br />

Today, most studies are performed using<br />

computers. Some specialized studies<br />

require large computing resources, but<br />

many studies can now be performed on<br />

personal computers. A wide variety of<br />

software packages are available. In<br />

addition, many specialty firms exist which<br />

provide engineering service to perform<br />

such studies.<br />

Short Circuit Calculations<br />

The single-line diagram serves as the<br />

starting point for the system study and<br />

selection of equipment ratings. The<br />

single-line must be modified to show all<br />

power sources and capacities, and<br />

system impedances. Sources of short<br />

circuit current include utility connections,<br />

local generation, and all rotating machines<br />

connected to the system at the instant<br />

the fault occurs. The system study should<br />

consider various fault types (line-to-line<br />

and line-to-ground) and fault locations.<br />

The value of normal load current in a<br />

circuit depends on the load connected,<br />

and is essentially independent of the<br />

capacity of the power system. On the<br />

other hand, the short circuit current<br />

depends almost entirely on the capacity<br />

of the power system, not the size of the<br />

load.<br />

The total fault current consists of a<br />

symmetrical AC component,<br />

superimposed on a DC (offset)<br />

component. Hence, the total fault current<br />

is asymmetric with respect to the current<br />

axis. The value of the DC component<br />

depends on the point of the voltage wave<br />

at which the fault was initiated. For<br />

system studies, it is assumed that the<br />

fault is initiated at the worst point, to<br />

produce a “fully offset” fault current. This<br />

is illustrated in Figure 25.<br />

Short circuit currents are determined by<br />

the system impedance, including both<br />

reactance and resistance. The effect of<br />

the reactance is to cause the initial fault<br />

current to be high, with the fault current<br />

declining as time proceeds. This is<br />

represented as the summation of a DC<br />

component which decays relatively<br />

rapidly over time, and an AC component,<br />

which decays at a slower rate. The rate of<br />

decay of the components depends on the<br />

system X / R ratio.<br />

Since the reactance of rotating machines<br />

varies with the time from fault initiation,<br />

the short circuit calculations must use the<br />

appropriate machine reactance values.<br />

Subtransient reactance (X” d ) governs<br />

current flow for approximately the first 6<br />

cycles of a fault. Then, transient<br />

reactance (X’ d ) determines current flow<br />

up to around 30-120 cycles, depending on<br />

the machine. After this, synchronous<br />

reactance (X d ) applies, but studies<br />

seldom use this value as faults are not<br />

usually allowed to persist for this length<br />

of time.<br />

For transformers, the actual tested value<br />

of the transformer impedance is used. If<br />

this is not available, use design<br />

impedance adjusted to the minimum<br />

value allowed by manufacturing tolerance<br />

of + – 7.5%. For example, a 5.75% design<br />

unit has a tolerance range of 5.32-6.18%,<br />

and 5.32% would be used in a system<br />

study prior to manufacture.<br />

TECHNICAL<br />

Figure 25. Structure of Asymmetrical Current Wave (Fully Offset)<br />

T-12<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Technical<br />

Current Limiting Circuit Breaker Technology<br />

Selection<br />

Fuseless Current Limiting<br />

Circuit Breakers<br />

The technology of Siemens Sentron ®<br />

fuseless current limiting circuit breakers<br />

was developed to meet the demands of<br />

modern distribution systems. It is<br />

not uncommon for today’s systems to<br />

have prospective short circuit currents<br />

approaching 200,000 amperes. Users<br />

demanded the protection and flexibility<br />

afforded by circuit breakers, without<br />

the nuisance and expense of fuse<br />

replacement.<br />

Underwriters Laboratories, in UL489-<br />

2.4A, defines a fuseless current limiting<br />

circuit breaker as one that “does not<br />

employ a fusible element, and that when<br />

operating within its current-limiting range,<br />

limits the let-through l 2 t to a value less<br />

than the l 2 t of a half-cycle wave of the<br />

symmetrical prospective current.”<br />

l 2 t is an expression which allows<br />

comparison of the energy available as a<br />

result of fault current flow. As used in<br />

current limiting discussions, l 2 t refers to<br />

the energy released between the initiation<br />

of the fault current and the clearing of the<br />

circuit.<br />

Figure 26 relates the “prospective l 2 t” to<br />

the energy allowed by a Sentron current<br />

limiting circuit breaker, or “let-through<br />

l 2 t”. The upper curve represents the<br />

maximum I 2 the circuit can produce,<br />

unaltered by the presence of any<br />

protective device. The lower curve<br />

illustrates the reduction in energy<br />

allowed when Sentron current limiting<br />

circuit breakers are used.<br />

Figure 26. Reduction of l 2 t Let-Through<br />

with Current-Limiting Technology<br />

Figure 27. Current Limitation<br />

Figure 27 illustrates how the Sentron<br />

circuit breaker limits the energy under<br />

fault conditions. The upper curve<br />

illustrates the first half-cycle wave of<br />

prospective fault current. To qualify as<br />

truly current limiting, the circuit breaker<br />

must prevent the current value from<br />

reaching the maximum value that it<br />

would reach if the circuit breaker were<br />

not connected in the circuit.<br />

The Sentron circuit breakers use the<br />

“blow-apart” contact principle to<br />

accomplish current limitation. This<br />

principle is based on the electro-magnetic<br />

repulsion of adjacent conductors which<br />

carry current in opposite directions.<br />

The contact arms are arranged to create<br />

opposing magnetic fields. As fault current<br />

rises, magnetic repulsion forces the<br />

contacts to separate completely. The<br />

higher the fault current, the faster this<br />

“blow-apart” action occurs.<br />

As figure 27 illustrates, the energy letthrough<br />

with the current limiting Sentron<br />

circuit breaker is decreased significantly.<br />

This provides better protection for<br />

downstream equipment, and reduces<br />

damage.<br />

Applications and Ratings<br />

Sentron current limiting circuit breakers<br />

are designed for use in load centers,<br />

power panelboards, distribution<br />

switchboards, secondary unit<br />

substations, and all types of individual<br />

enclosures where the available fault<br />

currents exceed the interrupting ratings<br />

of heavy duty and extra-heavy duty<br />

molded case circuit breakers.<br />

Sentron circuit breakers have ratings of<br />

15 through 1600 amperes, 240 through<br />

600 volts AC, with up to 200,000<br />

symmetrical amperes interrupting rating.<br />

T TECHNICAL<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog T-13


Technical<br />

Series-Connected Combination Ratings<br />

Series-Connected Rating<br />

A series-connected rating can be assigned<br />

to a combination of compo nents —<br />

typically circuit breakers — which has<br />

been tested in combination to a higher<br />

interrupting rating than that of the lowest<br />

rated protective device of the<br />

combination. These ratings must be<br />

substantiated by extensive UL testing.<br />

General<br />

Article 110.9 of the 2011 National<br />

Electrical Code states the following:<br />

“Equipment intended to interrupt current<br />

at fault levels shall have an interrupting<br />

rating not less than the nominal circuit<br />

voltage and the current that is available<br />

at the line terminals of the equipment.<br />

Equipment intended to interrupt current<br />

at other than fault levels shall have an<br />

interrupting rating at nominal circuit<br />

voltage not less than the current that<br />

must be interrupted.”<br />

The difference between the phrases “at<br />

fault levels” and “at other than fault<br />

levels” is the part of the Code which<br />

makes series-connected systems<br />

possible. For example, the traditional<br />

method of satisfying the Code was to<br />

select each breaker in the series with an<br />

interrupting rating equal to or greater than<br />

the prospective fault current. The<br />

interrupting rating of a circuit breaker —<br />

stated in RMS symmetrical amperes — is<br />

the amount of short circuit current the<br />

device can safely interrupt and continue to<br />

function as a circuit breaker.<br />

Thus, if the prospective fault current at the<br />

line terminals of a panelboard is 100,000A<br />

RMS symmetrical, this traditional method<br />

would require that all the circuit breakers<br />

within the panelboard be rated at<br />

100,000A RMS symmetrical or greater<br />

interrupting capacity. This is illustrated in<br />

Figure 28. In the traditional system, both<br />

the main and the feeder breaker are<br />

subjected to several short circuit peaks.<br />

In a series-connected system, however,<br />

the individual components (or circuit<br />

breakers) have already been tested in<br />

series and the combination has been<br />

given an interrupting rating equal to or<br />

greater than various prospective fault<br />

currents which are available. The<br />

combination, therefore, acts as a single<br />

entity, and performs the same protective<br />

function as individual circuit breakers in<br />

the traditional method. The difference is<br />

that combinations in series-connected<br />

systems contain devices with lower<br />

interrupting ratings.<br />

Siemens circuit breakers used in series<br />

combinations which have passed<br />

extensive tests required by Underwriters<br />

Laboratories are listed in the UL<br />

Recognized Component Directory<br />

according to manufacturer’s name and<br />

type. The listing means that such circuit<br />

breakers are UL Recognized for the series<br />

interrupting ratings as noted in the<br />

Directory, and that they can be used as an<br />

entity to meet Article 110.9 of the NEC.<br />

Using the previous example, if the<br />

prospective fault current at the line<br />

terminals of the panelboard is 100,000<br />

amperes RMS symmetrical, the seriesconnected<br />

method would involve<br />

selecting a specific combination from the<br />

UL Recognized Component Directory with<br />

a rating of 100,000 amperes RMS<br />

symmetrical or greater interrupting<br />

capacity. That combination might include<br />

individual components which have lower<br />

individual interrupting ratings than 100,000<br />

amperes RMS symmetrical.<br />

However, all the components in the<br />

combination have been tested together<br />

and form an entity that will safety interrupt<br />

the prospective fault current of the<br />

particular situation being examined as long<br />

as the interrupting rating listed matches<br />

the prospective fault current.<br />

Selection<br />

With the advent of fuseless current<br />

limiting circuit breakers such as Sentron,<br />

another important development in seriesconnected<br />

combinations has emerged.<br />

Because of the fuseless current limiting<br />

circuit breaker’s extremely fast interrupting<br />

capability, this device provides more<br />

control over high prospective fault<br />

currents than traditional series-connected<br />

systems.<br />

The concept behind using fuseless current<br />

limiting circuit breakers as a component in<br />

a series-connected system is twofold: (1)<br />

higher interrupting ratings, and (2)<br />

increased control over peak current (i p ) and<br />

energy let-through (I 2 t).<br />

For example, a current limiting circuit<br />

breaker is placed at the side closest to the<br />

source of power and rated according to<br />

the prospective fault current available at<br />

the line-side terminals. In effect, doing this<br />

places a “shroud of protection” over the<br />

downstream components. Because of the<br />

inherent high interrupting capability of the<br />

current limiting circuit breaker, the breaker<br />

itself meets or exceeds the prospective<br />

short circuit current. Because of its current<br />

limiting action the prospective I 2 t never<br />

reaches downstream components. This is<br />

illustrated in Figure 29.<br />

It is important to recognize that the<br />

current limiting circuit breaker be an<br />

individual component in a UL tested<br />

combination, and that it is the combination<br />

itself — current limiting circuit breaker<br />

plus other circuit breakers — that forms<br />

entity specified in day-to-day applications.<br />

For specific series-connected<br />

combinations that have met UL<br />

requirements and are listed in the UL<br />

Recognized Component Directory, check<br />

with your local Siemens sales office listed<br />

on the back cover. Since the Directory is<br />

updated every six months, please check<br />

for additional combinations which may<br />

have been tested and approved.<br />

TECHNICAL<br />

T<br />

Figure 28 — Without Current Limiting<br />

Figure 29 — Series-Connected Protective Scheme With Current<br />

Limiting Main Circuit Breaker<br />

T-14<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Technical<br />

Harmonics / K-factor Ratings<br />

Non-Linear Loads<br />

When a sinusoidal voltage is applied to a<br />

linear load, the resultant current<br />

waveform takes on the shape of a sine<br />

wave as well. Typical linear loads are<br />

resistive heating and induction motors.<br />

In contrast, a non-linear load either:<br />

b Draws current during only part of the<br />

cycle and acts as an open circuit for<br />

the balance of the cycle,<br />

or<br />

b Changes the impedance during the<br />

cycle, hence the resultant waveform is<br />

distorted and no longer conforms to a<br />

pure sine wave shape<br />

In recent years, the use of electronic<br />

equipment has mushroomed in both<br />

offices and industrial plants. These<br />

electronic devices are powered by<br />

switching power supplies or some type<br />

of rectifier circuit. Examples of these<br />

devices used in offices are: computers,<br />

fax machines, copiers, printers, cash<br />

registers, UPS systems, and solid-state<br />

ballasts. In indus trial plants, one will find<br />

other electronic devices such as variable<br />

speed drives, HID lighting, solid-state<br />

starters and solid-state instruments. They<br />

all contribute to the distortion of the<br />

current waveform and the generation of<br />

harmonics. As the use of electronic<br />

equipment increases and it makes up a<br />

larger portion of the electrical load, many<br />

concerns are raised about its impact on<br />

the electrical power supply system.<br />

Selection<br />

Voltage of Current Waveform for Linear Loads (Sine Wave)<br />

Typical Current Waveform of Switching Power Supply<br />

A Non-Linear Current and Its Fundamental, Plus 3rd and 5th Harmonic Components<br />

Harmonics<br />

As defined by ANSI / IEEE Std. 519-1992,<br />

harmonic components are represented<br />

by a periodic wave or quantity having a<br />

frequency that is an integral multiple of<br />

the fundamental frequency. Harmonics<br />

are voltages or currents at frequencies<br />

that are integer multiples of the<br />

fundamental (60 Hz) frequency: 120 Hz,<br />

180 Hz, 240 Hz, 300 Hz, etc. Harmonics<br />

are designated by their harmonic number,<br />

or multiple of the fundamental frequency.<br />

Thus, a harmonic with a frequency of 180<br />

Hz (three times the 60 Hz fundamental<br />

frequency) is called the 3rd harmonic.<br />

Harmonics superimpose themselves on<br />

the fundamental waveform, distorting it<br />

and changing its magnitude. For instance,<br />

when a sine wave voltage source is<br />

applied to a non-linear load connected<br />

from a phase-leg to neutral on a 3-phase,<br />

4-wire branch circuit, the load itself will<br />

draw a current wave made up of the<br />

60 Hz fundamental frequency of the<br />

voltage source, plus 3rd and higher order<br />

odd harmonic (multiples of the 60 Hz<br />

fundamental frequency), which are all<br />

Figure 30 — Effect of Harmonics on Current Waveform<br />

gen erated by the non-linear load. Total<br />

Harmonic Distortion (THD) is calculated<br />

as the square root of the sum of the<br />

squares of all harmonics divided by the<br />

normal 60 Hz value.<br />

This yields an RMS value of distortion as<br />

a percentage of the fundamental 60 Hz<br />

waveform.<br />

Therefore, it is the percentage amount of<br />

odd harmonics (3rd, 5th, 7th ,..., 25th,...)<br />

present in the load which can affect the<br />

transformer, and this condition is called a<br />

“Non-Linear Load” or “Non-Sinusoidal<br />

Load”. To determine what amount of<br />

harmonic content is present, a K-Factor<br />

calculation is made instead of using the<br />

THD formula. The total amount of<br />

harmonics will determine the percentage<br />

of non-linear load, which can be specified<br />

with the appropriate K-Factor rating.<br />

T TECHNICAL<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog T-15


Technical<br />

Harmonics / K-factor Ratings<br />

Typical Symptoms of Harmonic<br />

Problems<br />

b Distribution / lighting transformers<br />

overheating even when measured load<br />

current is within transformer rating<br />

b Neutral cable / bus overheating even<br />

with balanced load<br />

b Fuses blowing and circuit breakers<br />

tripping at currents within rating<br />

Effect Of Harmonics On Transformers<br />

Non-sinusoidal current generates extra<br />

losses and heating of transformer coils<br />

thus reducing efficiency and shortening<br />

the life expectancy of the transformer.<br />

Coil losses increase with the higher<br />

harmonic frequencies due to higher eddy<br />

current loss in the conductors.<br />

Furthermore, on a balanced linear power<br />

system, the phase currents are 120<br />

degrees out of phase and offset one<br />

another in the neutral conductor. But with<br />

the “Triplen” harmonics (multiple of 3)<br />

the phase currents are in phase and they<br />

are additive in this neutral conductor. This<br />

may cause installations with non-linear<br />

loads to double either the size or number<br />

of neutral conductors.<br />

Table 17.5<br />

Type<br />

K4<br />

K13<br />

K20<br />

K30<br />

Linear<br />

Load<br />

100%<br />

100%<br />

100%<br />

100%<br />

K-Factor Ratings<br />

Non-<br />

Linear<br />

Load<br />

50%<br />

100%<br />

125%<br />

150%<br />

Total K-<br />

Factor<br />

Load Valve<br />

4.0<br />

13.0<br />

20.0<br />

30.0<br />

Measurement of Harmonics<br />

For existing installations, the extent of<br />

the harmonics can be measured with<br />

appropriate instruments commonly<br />

referred to as “Power Harmonic<br />

Analyzers”. This service is offered by<br />

many consulting service organizations.<br />

For new construction, such information<br />

may not be obtainable. For such<br />

situations, it is best to assume the worse<br />

case condition based on experience with<br />

the type and mix of loads.<br />

Sizing Transformers for Non-Linear<br />

Loads<br />

ANSI / IEEE C57.110-2008 has a<br />

procedure for de-rating standard<br />

distribution transformers for non-linear<br />

loading. However this is not the only<br />

approach. A transformer with the<br />

appropriate K-Factor specifically designed<br />

for non-linear loads can be specified.<br />

K-Factors<br />

K-Factor is a ratio between the additional<br />

losses due to harmonics and the eddy<br />

losses at 60 Hz. It is used to specify<br />

transformers for non-linear loads. Note<br />

that K-Factor transformers do not<br />

eliminate harmonic distortion; they<br />

withstand the non-linear load condition<br />

without overheating.<br />

Calculating K-Factor Loads<br />

1. List the kVA value for each load<br />

category to be supplied. Next, assign a<br />

K-factor designation that corresponds<br />

to the relative level of harmonics<br />

drawn by each type of load. Refer to<br />

Table 17.7.<br />

Table 17.7<br />

Description<br />

Estimating K-Factor Loads <br />

Incandescent Lighting<br />

Electric Resistance Heating<br />

Motors (without solid state drives)<br />

Control Transformers / Electromagnetic Control Devices<br />

Motor-Generators (without solid state drives)<br />

Standard Distribution Transformers<br />

Electric Discharge Lighting (HID)<br />

UPS with Optional Input Filter<br />

Welders<br />

Induction Heating Equipment<br />

PLCs and Solid State Controls<br />

Telecommunications Equipment (PBX)<br />

UPS without Input Filtering<br />

Multiwire Receptacle Circuits in General Care Areas of Health Care Facilities,<br />

Schools, etc.<br />

Multiwire Receptacle Circuits Supplying Testing Equipment on an Assembly Line<br />

Main-Frame Computer Loads<br />

Solid State Motor Drives (variable speed drives)<br />

Multiwire Receptacle Circuits in Critical Care Areas in Hospitals<br />

Multiwire Receptacle Circuits in Industrial, Medical and Educational Laboratories<br />

Multiwire Receptacle Circuits in Commercial Office Spaces<br />

Small Main-Frames (mini and micro)<br />

Typical loads and K-Factor values for estimating purposes only.<br />

2. Multiply the kVA of each load or load<br />

category times the Index of Load<br />

K-rating (I LK ) that corresponds to the<br />

assigned K-factor rating. This result is<br />

an indexed kVA-I LK value.<br />

KVA x I LK = kVA-I LK .<br />

3. Tabulate the total connected load kVA<br />

for all load categories to be supplied.<br />

4. Next, add-up the kVA-I LK values for all<br />

loads or load categories to be supplied<br />

by the transformer.<br />

5. Divide the grand total kVA-I LK value by<br />

the total kVA load to be supplied. This<br />

will give an average I LK for that combination<br />

of loads. Total kVA-I LK / Total<br />

kVA = average I LK .<br />

6. From Table 17.7 find the K-factor rating<br />

whose I LK is equal to or greater than<br />

the calculated I LK .<br />

K-Factor<br />

K1<br />

K4<br />

K13<br />

K20<br />

Selection<br />

I LK<br />

0.00<br />

25.82<br />

57.74<br />

80.94<br />

K30 123.54<br />

TECHNICAL<br />

T<br />

T-16<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Technical<br />

Table 1<br />

Copper Conductors<br />

Aluminum Conductors<br />

Copper-Clad Aluminum Conductors<br />

60°C 75°C 90°C 60°C 75°C 90°C<br />

Size (140°F) (167°F) (194°F) (140°F) (167°F) (194°F) Size<br />

Types Types Types Types Types Types<br />

TBS<br />

TBS,<br />

SA<br />

SA, SIS,<br />

SIS<br />

THHN<br />

AWG RHW FEP RHW THHW AWG<br />

Kcmil THW FEPB THHW THW-2, THWN-2, Kcmil<br />

THWN RHH THW RHH, RHW-2<br />

XHHW THHN THWN USE-2<br />

TW USE THHW TW XHHW XHH, XHHW<br />

UF ZW XHHW UF USE XHHW-2, ZW-2<br />

0018 — — 014 — — — —<br />

0016 — — 018 — — — —<br />

0014 b 015 020 025 — — — —<br />

0012 b 020 025 030 015 020 a 025 a 12<br />

0010 b 030 035 040 025 030 a 035 a 10<br />

0008 040 050 055 035 040 045 8<br />

0006 055 065 075 040 050 055 6<br />

0004 070 085 095 055 065 075 4<br />

0003 085 100 115 065 075 085 3<br />

0002 095 115 130 075 090 100 2<br />

0001 110 130 145 085 100 115 1<br />

0000 1 ⁄0 125 150 170 100 120 135 0000 1 ⁄0<br />

0000 2 ⁄0 145 175 195 115 135 150 0000 2 ⁄0<br />

0000 3 ⁄0 165 200 225 130 155 175 0000 3 ⁄0<br />

0000 4 ⁄0 195 230 260 150 180 205 0000 4 ⁄0<br />

250 215 255 290 170 205 230 250<br />

300 240 285 320 195 230 260 300<br />

350 260 310 350 210 250 280 350<br />

400 280 335 380 225 270 305 400<br />

500 320 380 430 260 310 350 500<br />

600 350 420 475 285 340 385 600<br />

700 385 460 520 315 375 425 700<br />

750 400 475 535 320 385 435 750<br />

800 410 490 555 330 395 440 800<br />

900 435 520 585 355 425 480 900<br />

1000 455 545 615 375 445 500 1000<br />

1250 495 590 665 405 485 545 1250<br />

1500 525 625 705 435 520 585 1500<br />

1750 545 650 735 455 545 615 1750<br />

2000 555 665 750 470 560 630 2000<br />

General<br />

NEC Table 310.15(B)(16) (formerly Table 310.16) Allowable Ampacities of Insulated Conductors Rated Up to and Including<br />

2000 Volts, 60°C Through 90°C (140°F Through 194°F), Not More Than Three Current-Carrying Conductors in Raceway,<br />

Cable, or Earth (Directly Buried), Based on Ambient Temperature of 30°C (86°F) a<br />

Table 2<br />

Correction Factors for Ambient Temperature Over 30°C (86°F) Based on NEC Table 310.15(B)(2)(A)<br />

Ambient For ambient temperature over 30°C, (86°F) multiply the ampacities shown above by the appropriate factor Ambient<br />

Temperature°C shown below. Temperature°F<br />

10 or less 1.29 1.20 1.15 1.29 1.20 1.15 50 or less<br />

11-15 1.22 1.15 1.12 1.22 1.15 1.12 51-59<br />

16-20 1.15 1.11 1.08 1.15 1.11 1.08 60-68<br />

21–25 1.08 1.05 1.04 1.08 1.05 1.04 69–77<br />

26–30 1.00 1.00 1.00 1.00 1.00 1.00 78–86<br />

31–35 .91 .94 .96 .91 .94 .96 87–95<br />

36–40 .82 .88 .91 .82 .88 .91 96–104<br />

41–45 .71 .82 .87 .71 .82 .87 105–113<br />

46–50 .58 .75 .82 .58 .75 .82 114–122<br />

51–55 .41 .67 .76 .41 .67 .76 123–131<br />

56–60 — 0.58 .71 — 0.58 .71 132–140<br />

61-65 — 0.47 0.65 — 0.47 0.65 141-149<br />

66-70 — 0.33 0.58 — 0.33 0.58 150-158<br />

71-75 — — 0.50 — — 0.50 159-167<br />

76-80 — — 0.41 — — 0.41 168-176<br />

81-85 — — 0.29 — — 0.29 177-185<br />

T TECHNICAL<br />

aRefer to 310.15(B)(2) for the ampacity correction factors<br />

where the ambient temperature is other than 30°C (86°F)<br />

bRefer to 240.4(D) for conductor overcurrent protection<br />

limitations.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog T-17


Technical<br />

General<br />

T<br />

TECHNICAL<br />

Table 4A<br />

Table 4B<br />

Motor Full-Load Currents of Three Motor Full-Load Currents<br />

Phase AC Induction Type Motors a In Amperes, Single Phase, AC<br />

Motor<br />

Horsepower 115V 230V<br />

Rating<br />

Current in Amperes<br />

00 1 ⁄6 4.4 2.2<br />

Horsepower 208V 230V 460V 575V 00 1 ⁄4 5.8 2.9<br />

000 1 ⁄4 1.11 .96 .48 .38 00 1 ⁄3 7.2 3.6<br />

00<br />

000 1 ⁄3 1.34 1.18 .59 .47<br />

⁄2 9.8 4.9<br />

00 3 ⁄4 13.8 6.9<br />

000 1 ⁄2 2.4 2.2 1.1 .9 01 16 8<br />

000 3 ⁄4 3.5 3.2 1.6 1.3 01 1 ⁄2 20 10<br />

001 4.6 4.2 2.1 1.7<br />

02 24 12<br />

03 34 17<br />

001 1 ⁄2 6.6 6 3 2.4<br />

05 56 28<br />

002 7.5 6.8 3.4 2.7 07 1 ⁄2 80 40<br />

003 10.6 9.6 4.8 3.9 10 100 50<br />

005 16.7 15.2 7.6 6.1<br />

007 1 ⁄2 24.2 22.0 11.0 9.0<br />

010 30.8 28.0 14.0 11.0<br />

015 46.2 42.0 21.0 17.0<br />

020 59.4 54 27 22<br />

025 74.8 68 34 27<br />

030 88 80 40 32<br />

040 114 104 52 41<br />

050 143 130 65 52<br />

060 169 154 77 62<br />

075 211 192 96 77<br />

100 273 248 124 99<br />

125 343 312 156 125<br />

150 396 360 180 144<br />

200 528 480 240 192<br />

250 —0 —0 302 242<br />

300 —0 —0 361 289<br />

350 —0 —0 414 336<br />

400 —0 —0 477 382<br />

450 —0 —0 515 412<br />

500 —0 —0 590 472<br />

aValues may vary depending on manufacturer,<br />

type of motor and NEMA design.<br />

For full load currents of 200 volt motors, increase the<br />

corresponding 230 volt motor full-load current by<br />

15 percent.<br />

Table 5 Notes:<br />

1. Primary source available is assumed as 500 MVA at the<br />

primary of the transformer with a source circuit X/R<br />

ratio of 12.<br />

2. Motor contribution is included in the table at twice the<br />

full-load current for 208 volt transformers and at 4<br />

times the full-load current for 240 volt and 480 volt<br />

transformers. These values are derived from the<br />

assumption that 208 volt systems are 50% motor load<br />

and 240 and 480 volt systems are 100% motor load.<br />

3. All short circuit current values are in symmetrical<br />

RMS amperes.<br />

Table 4C<br />

Motor Full-Load Currents<br />

In Amperes, DC<br />

Horsepower 120V 240V<br />

00 1 ⁄4 3.1 1.6<br />

00 1 ⁄3 4.1 2.0<br />

00 1 ⁄2 5.4 2.7<br />

00 3 ⁄4 7.6 3.8<br />

01 9.5 4.7<br />

01 1 ⁄2 13.2 6.6<br />

02 17 8.5<br />

03 25 12.2<br />

05 40 20<br />

07 1 ⁄2 58 29<br />

10 76 38<br />

Table 4D<br />

Conversion Table of Polyphase Design B, C, D, and E Maximum Locked-Rotor<br />

Currents for Selection of Disconnecting Means and Controllers as Determined<br />

from Horsepower and Voltage Rating and Design Letter For use only with<br />

Sections 430-110, 440-12, 440-41, and 455-8(c) of the National Electric Code.<br />

Maximum Motor Locked-Rotor Current Amperes<br />

Two and Three Phase Design B, C, D, and E<br />

Rated 115 Volts 200 Volts 208 Volts 230 Volts 460 Volts 575 Volts<br />

HP B, C, D E B, C, D E B, C, D E B, C, D E B, C, D E B, C, D E<br />

000 1 ⁄2 40 40 23 23 22.1 22.1 20 20 10 10 8 8<br />

000 3 ⁄4 50 50 28.8 28.8 27.6 27.6 25 25 12.5 12.5 10 10<br />

001 60 60 34.5 34.5 33 33 30 30 15 15 12 12<br />

001 1 ⁄2 80 80 46 46 44 44 40 40 20 20 16 16<br />

002 100 100 57.5 57.5 55 55 50 50 25 25 20 20<br />

003 —0 —0 73.6 84 71 81 64 73 32 36.5 25.6 29.2<br />

005 —0 —0 105.8 140 102 135 92 122 46 61 36.8 48.8<br />

007 1 ⁄2 —0 —0 146 210 140 202 127 183 63.5 91.5 50.8 73.2<br />

010 —0 —0 186.3 259 179 249 162 225 81 113 64.8 90<br />

015 —0 —0 267 388 257 373 232 337 116 169 93 135<br />

020 —0 —0 334 516 321 497 290 449 145 225 116 180<br />

025 —0 —0 420 646 404 621 365 562 183 281 146 225<br />

030 —0 —0 500 775 481 745 435 674 218 337 174 270<br />

040 —0 —0 667 948 641 911 580 824 290 412 232 330<br />

050 —0 —0 834 1185 802 1139 725 1030 363 515 290 412<br />

060 —0 —0 1001 1421 962 1367 870 1236 435 618 348 494<br />

075 —0 —0 1248 1777 1200 1708 1085 1545 543 773 434 618<br />

100 —0 —0 1668 2154 1603 2071 1450 1873 725 937 580 749<br />

125 —0 —0 2087 2692 2007 2589 1815 2341 908 1171 726 936<br />

150 —0 —0 2496 3230 2400 3106 2170 2809 1085 1405 868 1124<br />

200 —0 —0 3335 4307 3207 4141 2900 3745 1450 1873 1160 1498<br />

250 —0 —0 —00 —00 —00 —00 —00 —00 1825 2344 1460 1875<br />

300 —0 —0 —00 —00 —00 —00 —00 —00 2200 2809 1760 2247<br />

350 —0 —0 —00 —00 —00 —00 —00 —00 2550 3277 2040 2622<br />

400 —0 —0 —00 —00 —00 —00 —00 —00 2900 3745 2320 2996<br />

450 —0 —0 —00 —00 —00 —00 —00 —00 3250 4214 2600 3371<br />

500 —0 —0 —00 —00 —00 —00 —00 —00 3625 4682 2900 3746<br />

Table 5<br />

Normal-Load and Fault Currents of Three Phase Transformers<br />

Transformer<br />

Characteristics<br />

AC Voltage 3-Phase<br />

3-Phase 208V 240V 480V<br />

Normal Load Short Normal Load Short Normal Load Short<br />

kVA % Continuous Circuit Continuous Circuit Continuous Circuit<br />

Rating Impedance Amperes Current Amperes Current Amperes Current<br />

112.5 3.90 312 8,007 271 6,940 135 3,470<br />

150 3.70 416 11,253 361 9,753 180 4,876<br />

225 4.70 625 13,288 541 11,517 271 5,758<br />

300 4.50 834 18,505 722 16,038 361 8,019<br />

500 4.50 1388 30,842 1203 26,730 601 13,365<br />

750 5.75 2080 36,206 1804 31,379 902 15,689<br />

1000 5.75 2780 48,275 2406 41,838 1203 20,919<br />

1500 5.75 4162 72,412 3610 62,575 1805 31,379<br />

2000 5.75 —00 —0 0 0 4812 83,676 2406 41,838<br />

2500 5.75 —00 —0 0 0 6010 104,596 3008 52,298<br />

T-18<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Technical<br />

Table 6<br />

Electrical Formulas for Finding Amperes, Horsepower, Kilowatts and kVA<br />

Alternating Current<br />

To Find Single Phase Two Phase a , Four Wire Three Phase Direct Current<br />

Kilowatts<br />

I x E x pf I x E x 2 x pf I x E x 1.73 x pf I x E<br />

1000 1000 1000 1000<br />

kVA<br />

I x E I x E x 2 I x E x 1.73<br />

1000 1000 1000<br />

Horsepower I x E x % EFF x pf I x E x 2 x % EFF x pf I x E x 1.73 x % EFF x pf I x E x % EFF<br />

(Output) 746 746 746 746<br />

Amperes when<br />

HP x 746 HP x 746 HP x 746 HP x 746<br />

Horsepower<br />

E x % EFF x pf 2 x E x % EFF x pf 1.73 x E x % EFF x pf E x % EFF<br />

is Known<br />

Amperes when<br />

KW x 1000 KW x 1000 KW x 1000 KW x 1000<br />

Kilowatts<br />

E x pf 2 x E x pf 1.73 x E x pf E<br />

is Known<br />

Amperes when kVA x 1000 kVA x 1000 kVA x 1000<br />

kVA is Known E 2 x E 1.73 x E<br />

General<br />

Average Efficiency and Power Factor<br />

Values of Motors<br />

When the actual efficiencies and power<br />

factors of the motors to be controlled are<br />

not known, the following approximations<br />

may be used.<br />

Efficiencies:<br />

DC motors, 35 horsepower<br />

and less 80% to 85%<br />

DC motors, above<br />

35 horsepower 85% to 90%<br />

Synchronous motors<br />

(at 100% power factor) 92% to 95%<br />

“Apparent” Efficiencies<br />

( = Efficiency x Power Factor);<br />

Three phase induction motors,<br />

25 horsepower and less 70%<br />

Three phase induction motors<br />

above 25 horsepower 80%<br />

These figures may be decreased<br />

slightly for single phase and two phase<br />

induction motors.<br />

Table 7 b<br />

aIn three wire, two phase circuits the current in<br />

the common conductor is 1.41 times that in either<br />

other conductor.<br />

Fault-Current Calculation on Low-<br />

Voltage AC Systems<br />

In order to determine the maximum<br />

interrupting rate of the circuit breakers in<br />

a distribution system it is necessary to<br />

calculate the current which could flow<br />

under a three phase bolted short circuit<br />

condition. For a three phase system the<br />

maximum available fault current at the<br />

secondary side of the transformer can be<br />

obtained by use of the formula:<br />

I SC =<br />

kVA x 100<br />

KV x √3 x % Z<br />

where:<br />

I SC = Symmetrical RMS amperes of<br />

fault current.<br />

kVA = Kilovolt-ampere rating of<br />

transformers.<br />

KV = Secondary voltage in kilovolts.<br />

% Z = Percent impedance of primary line<br />

and transformer.<br />

Table 5 on page T-18 has been prepared to<br />

list the symmetrical RMS fault current<br />

which is available at the secondary<br />

terminals of the transformer.<br />

Grounding Electrode Conductor for AC Systems (From NEC Table 250–66)<br />

Size of Largest Service Entrance Conductor or Equivalent Area Size of Grounding<br />

for Parallel Conductors<br />

Electrode Conductor<br />

Aluminum or<br />

Aluminum or Copper<br />

Copper Clad<br />

Copper Clad Aluminum Copper Aluminum<br />

2 or smaller 1/0 or smaller 8 6<br />

1 or 1/0 2/0 or 3/0 6 4<br />

2/0 or 3/0 4/0 or 250 kcmil 4 2<br />

Over 3/0 to 350 kcmil Over 250 kcmil to 500 kcmil 2 1/0<br />

Over 350 kcmil to 600 kcmil Over 500 kcmil to 900 kcmil 1/0 3/0<br />

Over 600 kcmil to 1100 kcmil Over 900 kcmil to 1750 kcmil 2/0 4/0<br />

Over 1100 kcmil Over 1750 kcmil 3/0 250 kcmil<br />

bAdditional information and exceptions are stated in<br />

Article 250 — Grounding, National Electrical Code.<br />

Table 8 b<br />

Minimum Size Grounding Conductors<br />

for Grounding Raceways and<br />

Equipment (From NEC Table 250–122)<br />

Rating or Setting of<br />

Size<br />

Automatic Overcurrent<br />

Aluminum or<br />

Device in Circuit Ahead<br />

Copper<br />

of Equipment, Conduit Copper Clad<br />

etc., Not Exceeding Wire Aluminum<br />

(Amperes) Number Wire Number<br />

15 14 12<br />

20 12 10<br />

30 10 8<br />

40 10 8<br />

60 10 8<br />

100 8 6<br />

200 6 4<br />

300 4 2<br />

400 3 1<br />

500 2 1/0<br />

600 1 2/0<br />

800 1/0 3/0<br />

1000 2/0 4/0<br />

1200 3/0 250 kcmil<br />

1600 4/0 350 kcmil<br />

2000 250 kcmil 400 kcmil<br />

2500 350 kcmil 600 kcmil<br />

3000 400 kcmil 600 kcmil<br />

4000 500 kcmil 750 kcmil<br />

5000 700 kcmil 1200 kcmil<br />

6000 800 kcmil 1200 kcmil<br />

Note: Where necessary to comply with 250.4(A)(5) or (B)<br />

(4), the equipment grounding conductor shall be sized<br />

larger than given in this table.<br />

T TECHNICAL<br />

E = Volts I = Amperes<br />

% EFF = Per Cent Efficiency pf = Power Factor<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog T-19


Molded Case Circuit Breakers<br />

Capacitor Circuit Conductors<br />

Application<br />

Article 460.8 (NEC)<br />

The ampacity of capacitor circuit<br />

conductors shall not be less than 135%<br />

of the rated current of the capacitor. The<br />

ampacity of conductors that connect a<br />

capacitor to the terminals of a motor or<br />

to motor circuit conductors shall not be<br />

less than one-third the ampacity of the<br />

motor circuit conductors and in no case<br />

less than 135% of the rated current of<br />

the capacitor.<br />

Application<br />

Circuit breakers and switches for use<br />

with capacitors must have a current<br />

rating in excess of rated capacitor current<br />

to provide for overcurrent from<br />

overvoltages at fundamental frequency<br />

and harmonic currents. Use the following<br />

percent of capacitor current rating to size<br />

circuit breaker or fused and non-fused<br />

switches.<br />

b Enclosed Circuit Breakers 150%<br />

(Includes derating factor for enclosure)<br />

b Fused and non-fused 165%<br />

switches<br />

Due to switching surges, and possible<br />

overcurrent related to overvoltage and<br />

harmonics, Siemens recommends using<br />

150% of the capacitor current rating to<br />

size a thermal-magnetic circuit breaker<br />

for overload protection.<br />

If the circuit breaker is to be applied in an<br />

ambient greater than the marked rated<br />

ambient, it may be necessary to derate<br />

the continuous current rating. This is also<br />

true for applications where harmonic<br />

components are present. A basic formula<br />

to use for calculation of the capacitor<br />

current rating is as follows (assuming<br />

three phase application):<br />

Capacitor (Kvar) x 1000<br />

(Voltage / 1.732) x 3<br />

The interrupting rating of the circuit<br />

breaker or fuse must be selected to<br />

match the system fault current available<br />

at the point of the capacitor application.<br />

TECHNICAL<br />

T<br />

T-20<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog


Technical<br />

Fraction, Decimal, and Millimeter Equivalents<br />

Conversion Tables<br />

Fractions to Decimals to Millimeters<br />

Fractions Decimals Millimeters<br />

1/64 0.015625 0.397<br />

1/32 0.03125 0.794<br />

3/64 0.046875 1.191<br />

1/16 0.0625 1.588<br />

5/64 0.078125 1.984<br />

3/32 0.09375 2.381<br />

7/64 0.109375 2.778<br />

1/8 0.1250 3.175<br />

9/64 0.140625 3.572<br />

5/32 0.15625 3.969<br />

11/64 0.171875 4.366<br />

3/16 0.1875 4.763<br />

13/64 0.203125 5.159<br />

7/32 0.21875 5.556<br />

15/64 0.234375 5.953<br />

1/4 0.2500 6.350<br />

17/64 0.265625 6.747<br />

9/32 0.28125 7.144<br />

19/64 0.296875 7.541<br />

5/16 0.3125 7.938<br />

21/64 0.328125 8.334<br />

11/32 0.34375 8.731<br />

23/64 0.359375 9.128<br />

3/8 0.3750 9.525<br />

25/64 0.390625 9.922<br />

13/32 0.40625 10.319<br />

27/64 0.421875 10.716<br />

7/16 0.4375 11.113<br />

29/64 0.453125 11.509<br />

15/32 0.46875 11.906<br />

31/64 0.484375 12.303<br />

1/2 0.500 12.700<br />

33/64 0.515625 13.097<br />

17/32 0.53125 13.494<br />

35/64 0.546875 13.891<br />

9/16 0.5625 14.288<br />

37/64 0.578125 14.684<br />

19/32 0.59375 15.081<br />

39/64 0.609375 15.478<br />

5/8 0.6250 15.875<br />

41/64 0.640625 16.272<br />

21/32 0.65625 16.669<br />

43/64 0.671875 17.066<br />

11/16 0.6875 17.463<br />

45/64 0.703125 17.859<br />

23/32 0.71875 18.256<br />

47/64 0.734375 18.653<br />

3/4 0.7500 19.050<br />

49/64 0.765625 19.447<br />

25/32 0.78125 19.844<br />

51/64 0.796875 20.241<br />

13/16 0.8125 20.638<br />

53/64 0.828125 21.034<br />

27/32 0.84375 21.431<br />

55/64 0.859375 21.828<br />

7/8 0.8750 22.225<br />

57/64 0.890625 22.622<br />

29/32 0.90625 23.019<br />

59/64 0.921875 23.416<br />

15/16 0.9375 23.813<br />

61/64 0.953125 24.209<br />

31/32 0.96875 24.606<br />

63/64 0.984375 25.003<br />

1 1.000 25.400<br />

Millimeters to Inches a<br />

Millimeters Inches Millimeters Inches<br />

0.1 0.0039 46 1.8110<br />

0.2 0.0079 47 1.8504<br />

0.3 0.0118 48 1.8898<br />

0.4 0.0157 49 1.9291<br />

0.5 0.0197 50 1.9685<br />

0.6 0.0236 51 2.0079<br />

0.7 0.0276 52 2.0472<br />

0.8 0.0315 53 2.0866<br />

0.9 0.0354 54 2.1260<br />

55 2.1654<br />

1 0.0394 56 2.2047<br />

2 0.0787 57 2.2441<br />

3 0.1181 58 2.2835<br />

4 0.1575 59 2.3228<br />

5 0.1969 60 2.3622<br />

6 0.2362 61 2.4016<br />

7 0.2756 62 2.4409<br />

8 0.3150 63 2.4803<br />

9 0.3543 64 2.5197<br />

10 0.3937 65 2.5591<br />

11 0.4331 66 2.5984<br />

12 0.4724 67 2.6378<br />

13 0.5118 68 2.6772<br />

14 0.5512 69 2.7165<br />

15 0.5906 70 2.7559<br />

16 0.6299 71 2.7953<br />

17 0.6693 72 2.8346<br />

18 0.7087 73 2.8740<br />

19 0.7480 74 2.9134<br />

20 0.7874 75 2.9528<br />

21 0.8268 76 2.9921<br />

22 0.8661 77 3.0315<br />

23 0.9055 78 3.0709<br />

24 0.9449 79 3.1102<br />

25 0.9843 80 3.1496<br />

26 1.0236 81 3.1890<br />

27 1.0630 82 3.2283<br />

28 1.1024 83 3.2677<br />

29 1.1417 84 3.3071<br />

30 1.1811 85 3.3465<br />

31 1.2205 86 3.3858<br />

32 1.2598 87 3.4252<br />

33 1.2992 88 3.4646<br />

34 1.3386 89 3.5039<br />

35 1.3780 90 3.5433<br />

36 1.4173 91 3.5827<br />

37 1.4567 92 3.6220<br />

38 1.4961 93 3.6614<br />

39 1.5354 94 3.7008<br />

40 1.5748 95 3.7402<br />

41 1.6142 96 3.7795<br />

42 1.6535 97 3.8189<br />

43 1.6929 98 3.8583<br />

44 1.7323 99 3.8976<br />

45 1.7717 100 3.9370<br />

T TECHNICAL<br />

a0.001" = 0.0254 mm<br />

1 mm = 0.03937"<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog T-21


Technical<br />

Notes<br />