ACCESSIBILITY · UNIVERSAL DESIGN
ACCESSIBLE PARKING PLACES
USE OF THE BUILDING,
ESTABLISHMENT OR AREA
MINIMUM NUMBER OF ACCESSIBLE
PLACES
1.2m
2.6m
5.5m
PREFERRED PARKING: 1 EVERY 33 PARKING SPACES
TOTAL NUMBER OF PARKINGS: 134 <200
NO. OF PREFERRED PARKINGS: 134/33= 4
Dubai Universal Design Code, Feb 2017, Article 5.1
The width of the path free of obstacles should be enough to allow all pedestrians foreseen in all directions. It shall be always
more than 2000 mm and no one obstacle can reduce it to less than 1200mm.
Dubai Universal Design Code, Feb 2017, Article 6.13
They shall be located as close as possible and no more than 50 meters from the building entrance.
The minimum dimensions for the accessible parking place shall be 2600mm x 5500mm for angled parking schemes.
Accessible Route Accessibility Path Diagram Car Park Preferred Location PREFERRED and Dimensioning PARKING
1.6m
DIMENSIONS OF THE CABIN (WIDE X DEEP)
MINIMUM
RECOMMENDED
1.5m
1.5m
1.5m
1.5m
2.1m
1.5m
1.5m
1.5m
2.5m
SLOPE 8%
1.5m
2m
Dubai Universal Design Code, Feb 2017, Article 5.7
The maximum slope is 8%. There are level landings required at the beginning and at the end of every ramp run.
These landings shall have a minimum surface of 1500 mm x 1500 mm.
Dubai Universal Design Code, Feb 2017, Article 5.7
An elevator, lift or platform should be provided in every building with more than one floor. The dimensions
should be appropriate for the intended number of users and in all instances equal to or bigger than the specified
minimum dimensions of the cabin.
Dubai Universal Design Code, Feb 2017, Article 5.19
Any public use: 1 Accessible toilets for each gender should be provided in every floor.
Disabled Ramp Disabled Lift Disabled Toilet