<strong>HART</strong> SOLUTIONS<br />
From Spectrum Controls<br />
2012
Based in Seattle, Washington USA<br />
Founded in 1983<br />
Global Encompass Partner<br />
Corporate Overview<br />
All products supported through <strong>Rockwell</strong><br />
TechConnect phone support - worldwide<br />
Design and Manufacture products under the<br />
SC and RA label
DTAM Operator Interface<br />
Message View<br />
1983 1986<br />
27+ Years <strong>with</strong> <strong>Rockwell</strong><br />
22 Active Factored Products<br />
27+ Active Spectrum Label Products<br />
PLC-5<br />
1999<br />
SLC 500<br />
2000<br />
CompactLogix<br />
2001<br />
ControlLogix<br />
2002<br />
FlexI/O<br />
2004<br />
MicroLogix<br />
2008<br />
Point I/O<br />
2010<br />
Micro 800<br />
Plug-ins<br />
InView<br />
2012
1771 I/O<br />
Modules<br />
1746 I/O<br />
Modules<br />
Wide Range of Products<br />
1762 I/O<br />
Modules<br />
1734 I/O<br />
Modules<br />
1769 I/O<br />
Modules<br />
Product Family<br />
Webport<br />
Remote Access<br />
1756 I/O<br />
Modules<br />
InView<br />
Industrial<br />
Displays<br />
1794 I/O<br />
Modules<br />
2080<br />
Micro800<br />
Plug-ins
<strong>HART</strong> Primer<br />
UNIQUE COMMUNICATION SOLUTION<br />
The <strong>HART</strong> Protocol supports two way digital communications and is<br />
designed to complement traditional 4-20mA analog signal.<br />
<strong>HART</strong> - Highway Addressable Remote Transducer<br />
<strong>Analog</strong><br />
Signal<br />
Pre-defined Commands<br />
• Common Practice<br />
• General Purpose<br />
• Device Specific<br />
Large Installation Base<br />
Worldwide Support
<strong>Analog</strong><br />
and<br />
<strong>HART</strong><br />
Data<br />
Integrated Architecture<br />
Enterprise<br />
Client<br />
Applications<br />
SMART<br />
Field Devices<br />
Engineering<br />
Workstation<br />
RSLogix / RSLinx<br />
ENet<br />
Ethernet<br />
Device<br />
Management<br />
FieldCare/ AMS<br />
Third Party<br />
Visualizatio<br />
n<br />
RSView or<br />
PanelView<br />
Change<br />
Management<br />
& Maintenance<br />
Asset Center<br />
Point I/O CompactLogix Point I/O<br />
1734 <strong>HART</strong> I/O 1769 <strong>HART</strong> I/O 1734 <strong>HART</strong> I/O<br />
A family of <strong>HART</strong> I/O products
Software Components<br />
Device Management Application<br />
FieldCare / AMS / etc…<br />
Spectrum Controls<br />
CONNECTS<br />
<strong>Analog</strong>+<strong>HART</strong><br />
I/O Gateway<br />
<strong>Rockwell</strong> Software<br />
RSLinx<br />
Workstation<br />
+<br />
+<br />
Enterprise<br />
Client<br />
Applications<br />
ControlLogix<br />
CompactLogix<br />
Point I/O<br />
<strong>HART</strong> I/O<br />
<strong>HART</strong> I/O
Select device<br />
and perform<br />
parameterization.<br />
Online or Offline<br />
FieldCare Device Management<br />
<strong>HART</strong> I/O manages<br />
all communications
<strong>HART</strong> Diagnostics
Benefits Benefits of of an an Integrated Integrated Integrated Network<br />
Network<br />
Commissioning<br />
Efficient Documentation<br />
Simplified Device Configuration<br />
Operation<br />
Real-time diagnostics<br />
Regulatory Compliance (FDA, EPA…)<br />
Maintenance<br />
Automated Predictive Maintenance<br />
Audit Trail / Self Documentation
Existing acquisition methods<br />
• Handheld Communicator<br />
• Clip-on Serial Modem<br />
Limited to point-to-point connection!<br />
Requires you to be in the field!
Enterprise<br />
Client<br />
Applications<br />
ControlLogix<br />
w/ <strong>HART</strong> I/O<br />
<strong>HART</strong><br />
Field Devices<br />
<strong>HART</strong> Field Devices<br />
Highly Standardized<br />
Large Installation Base<br />
Less costly
• PV: Mass Flow Rate<br />
• SV: Totalizer 1<br />
• TV: Density<br />
• FV: Temperature<br />
• Volume Flow<br />
• Std. Volume Flow<br />
• Target Flow<br />
• Carrier Flow<br />
• Calculated Density<br />
• Totalizer 2<br />
• PV: Percent Travel<br />
• SV: Travel Setpoint<br />
• TV: Temperature<br />
• FV: Supply Pressure<br />
• Status Bytes<br />
RAM Fail<br />
Pressure Sensor Fail<br />
Temperature Sensor Fail<br />
Position Sensor Fail<br />
Instrument <strong>HART</strong> Data<br />
Read<br />
Read<br />
Endress+Hauser<br />
Mass Flow Meter<br />
Metso Control Valve<br />
Write<br />
Write<br />
• Set Flow Units<br />
• Reset Totalizers<br />
• Set Zero & Full Scale Range<br />
• Change K Factor<br />
• Change Pipe Diameter<br />
• Set Flow Direction<br />
• Set “Low Flow Cutoff”<br />
• Make Density Adjustments<br />
• Perform Diagnostic Tests<br />
• Set Zero & Span<br />
• Adjust For Mechanical Wear<br />
• Adjust Valve Sensitivity
Commissioning<br />
Quickly verify and document device configuration<br />
and calibration, assure the integrity of wiring, and<br />
confirm the operational capability of every control<br />
loop – all from one central location.<br />
Verify and tune valve performance by performing<br />
loop checks, via the network, and read back<br />
position.<br />
Generate and archive system configuration data<br />
more quickly.
Operation <strong>with</strong> <strong>HART</strong><br />
Normal Operation<br />
4-20mA<br />
PV: Percent Travel<br />
SV: Travel Set Point<br />
TV: Temperature<br />
FV: Supply Pressure<br />
Set Zero & Span<br />
Adjust For Mechanical Wear<br />
Adjust Valve Sensitivity<br />
Diagnostics / Maintenance<br />
4-20mA<br />
Status Byte<br />
RAM Fail<br />
Pressure Sensor Fail<br />
Temp Sensor Fail<br />
Position Sensor Fail<br />
Perform Diagnostic Tests<br />
Reduce on-site human intervention<br />
L<br />
G<br />
X<br />
C<br />
P<br />
U<br />
H<br />
A<br />
R<br />
T<br />
E<br />
N<br />
e<br />
t
Operation <strong>with</strong>out <strong>HART</strong><br />
<strong>Analog</strong> data from three field devices<br />
<strong>HART</strong> data is not being used<br />
PLC performs all calculations<br />
Dedicated field devices<br />
Dedicated I/O modules<br />
More loops to wire<br />
L<br />
G<br />
X<br />
C<br />
P<br />
U<br />
Pressure Flow<br />
E<br />
N<br />
e<br />
t<br />
Temperature
Read Data<br />
PV: Mass Flow Rate<br />
SV: Totalizer 1<br />
TV: Density<br />
FV: Temperature<br />
Volume Flow<br />
Std. Volume Flow<br />
Target Flow<br />
Totalizer 2<br />
Write Data<br />
Set Flow Units<br />
Reset Totalizers<br />
Set Zero & Full Scale<br />
Change K Factor<br />
Change Pipe Diameter<br />
Set Flow Direction<br />
Set Low Flow Cutoff<br />
Operation <strong>with</strong> <strong>HART</strong><br />
Simplified Installation/Wiring<br />
Better Quality Data<br />
More Diagnostic Information
Device Management<br />
Workstation vs. Field<br />
Scheduling<br />
Reduce downtime<br />
System Backup<br />
Fast Recovery<br />
Historical Reference<br />
Identify Trends<br />
Determine Reliability<br />
Maintenance <strong>with</strong> <strong>HART</strong>
Maintenance w/ E+H Fieldcare
Hardware Components<br />
1734-IExCH – 2 or 4 <strong>Channel</strong> <strong>Analog</strong> Input w/<strong>HART</strong><br />
1734-OE2CIH – 2 <strong>Channel</strong> Isolated <strong>Analog</strong> <strong>Output</strong><br />
<strong>with</strong> <strong>HART</strong> (Q4 2012)<br />
Add-on-Profile (AOP) provides tight integration<br />
DTM provides capability for remote configuration and<br />
monitoring<br />
Compatible <strong>with</strong> hand-held <strong>HART</strong> Communicator if<br />
necessary<br />
1769-IF4IH - 4 <strong>Channel</strong> <strong>Analog</strong> Input <strong>with</strong> <strong>HART</strong><br />
1769-OF4IH - 4 <strong>Channel</strong> <strong>Analog</strong> <strong>Output</strong> <strong>with</strong> <strong>HART</strong><br />
AOP and DTM for tight system integration<br />
710 VDC channel to channel isolation<br />
Connects device management interface
Point I/O 1734<br />
1734-IE2CH or IE4CH – 2 or 4 <strong>Channel</strong> <strong>Analog</strong> Input <strong>with</strong> <strong>HART</strong><br />
1734-OE2CIH – 2 <strong>Channel</strong> Isolated <strong>Analog</strong> <strong>Output</strong> <strong>with</strong> <strong>HART</strong> (Q4 2012)<br />
Add-on-Profile (AOP) provides tight integration to all compatible PLCs<br />
DTM provides capability for remote configuration and monitoring<br />
Compatible <strong>with</strong> hand-held <strong>HART</strong> Communicator if necessary<br />
1734-IF4U - 4 <strong>Channel</strong> Universal <strong>Analog</strong> Input (June 2012)<br />
AOP for tight integration to all compatible PLCs<br />
Voltage, Current, Thermocouple, RTD or Resistance<br />
type inputs can be configured individually<br />
on a per channel basis <strong>with</strong> the AOP<br />
16 bit resolution
CompactLogix <strong>HART</strong> Overview<br />
1769sc-IF4H<br />
1769sc-OF4H<br />
4 <strong>Channel</strong>s of <strong>Analog</strong> Input or <strong>Output</strong><br />
710vdc <strong>Channel</strong>-to-<strong>Channel</strong> Isolation<br />
Input channels selectable…<br />
Voltage or Current or Current + <strong>HART</strong><br />
<strong>Output</strong> channels selectable…<br />
Current or Current + <strong>HART</strong><br />
CONNECTS device management<br />
interface<br />
Standard wiring / terminal blocks<br />
Works just like a standard analog but has <strong>HART</strong>!
RA Tools<br />
Integrated<br />
Architecture<br />
Builder<br />
Proposal Works<br />
Full Support<br />
Through RA<br />
TechConnect<br />
Datasheets<br />
User Manual<br />
Technical Notes<br />
Application Notes<br />
Marketing Support<br />
Print Website<br />
Datasheets<br />
Technical<br />
Documentation<br />
Sample Programs<br />
I/O Profiles<br />
Knowledge Base<br />
CD<br />
Catalog<br />
Datasheets<br />
Technical<br />
Documentation<br />
Sample Programs<br />
I/O Profiles<br />
DTM for <strong>HART</strong> I/O<br />
Corporate<br />
Leading Edge<br />
Business<br />
Processes<br />
Heavy Investment<br />
In R & D<br />
Knowledgeable<br />
Application<br />
Support
Worldwide Telephone Technical Support<br />
Worldwide<br />
Phone<br />
Support<br />
<strong>Rockwell</strong> <strong>Automation</strong> TechConnect<br />
For All Spectrum Products<br />
Sample<br />
Projects<br />
Application<br />
Support<br />
Knowledge<br />
Base
<strong>Channel</strong> to Market<br />
Spectrum Controls Works<br />
Exclusively With <strong>Rockwell</strong>’s <strong>Channel</strong><br />
Purchase<br />
Products<br />
Locally<br />
Pricing &<br />
Discounts<br />
Same as<br />
<strong>Rockwell</strong><br />
Local<br />
Support
Contact Information<br />
Office Address<br />
1705 132 nd Ave NE<br />
Bellevue, WA 98005 USA<br />
Tel: +1 425-746-9481<br />
Fax: +1 425-641-9473<br />
Email: spectrum@spectrumcontrols.com<br />