Series <strong>SV</strong> D-sub Connector<br />

56<br />

Manifold Electrical Wiring<br />

®<br />

10F/16F D-sub Connector Type (25 pins)<br />

Usable number of solenoids<br />

Model Maximum number of solenoids<br />

Tie-rod base type 10<br />

Cassette base type 16<br />

Light/Surge<br />

voltage suppressor<br />

Light/Surge<br />

voltage suppressor<br />

Light/Surge<br />

voltage suppressor<br />

Light/Surge<br />

voltage suppressor<br />

<strong>SV</strong>1000<br />

to<br />

<strong>SV</strong>4000<br />

<strong>SV</strong>1000<br />

<strong>SV</strong>2000<br />

13<br />

12<br />

11<br />

2<br />

1<br />

25<br />

24<br />

15<br />

14<br />

23<br />

18<br />

23<br />

Common<br />

Common<br />

SOL. B<br />

SOL. A<br />

Station 1<br />

SOL. B<br />

SOL. A<br />

Station 2<br />

SOL. B<br />

SOL. A<br />

Station 1<br />

• This circuit has double wiring specifications for up to 11 stations. Since the usable number of<br />

solenoids differs depending on the manifold type, refer to the table below. In the case of single<br />

solenoids, connect to SOL. A. Furthermore, when wiring is specified on a manifold specification<br />

sheet, connections are made without skipping any connectors, and signals A for single and A, B for<br />

double are in order 1→14→2→15, etc.<br />

• Stations are counted starting from station 1 on the D side (connector side).<br />

• Since solenoid valves do not have polarity, either the +COM or –COM can be used.