IBA catalog GB int60p 10 v9 - IBA Molecular
IBA catalog GB int60p 10 v9 - IBA Molecular
IBA catalog GB int60p 10 v9 - IBA Molecular
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
INTERNATIONAL CATALOGUE ALOGUE<br />
PULMOCIS ®<br />
Kit for the preparation of technetium ( 99m Tc) human albumin macroaggregates<br />
injection<br />
Each vial contains :<br />
Human Albumin Macroaggregates (MAA) 2.0 mg<br />
Stannous chloride dihydrate<br />
Sodium chloride<br />
Non denaturated human albumin<br />
Under nitrogen atmosphere<br />
Particles number per vial 2 to 4 million<br />
Particle size Number of MAA � 150 �m - 0<br />
Number of MAA � <strong>10</strong>0 �m - � <strong>10</strong><br />
Volume of pertechnetate 99m Tc<br />
to use for reconstitution 2.5 - <strong>10</strong> ml<br />
Radiochemical purity � 90 %<br />
Colour Homogeneous suspension<br />
Storage 12 months at 2 - 8 °C<br />
Activity per vial 92.5 to 3700 MBq<br />
Indications Pulmonary perfusion scintigraphy<br />
Venoscintigraphy<br />
Posology 37 to 185 MBq<br />
Stability of labelled product 8 h at 2 - 8°C<br />
Time between injection and examination Immediately<br />
Availability from stock<br />
Number of radiolabelled preparations per kit 5<br />
RENOCIS ®<br />
Kit for the preparation of technetium ( 99m Tc) succimer injection<br />
Each vial contains :<br />
Dimercaptosuccinic acid (DMSA) 1.0 mg<br />
Stannous chloride dihydrate<br />
Inositol<br />
Ascorbic acid<br />
Sodium hydroxide (pH adjustment)<br />
Under nitrogen atmosphere<br />
Volume of pertechnetate 99m Tc<br />
to use for reconstitution 1 to 6 ml<br />
Radiochemical purity � 95 %<br />
Storage 12 months at 2 to 8°C<br />
Stability of labelled product 8 h at 2 - 8°C<br />
Activity per vial Maximum 3.7 <strong>GB</strong>q<br />
Indications /Posology Static planar or tomographic renal imaging :<br />
- Morphological studies of renal cortex<br />
- Individual kidney function<br />
- Location of ectopic kidney<br />
30 to 120 MBq<br />
Time between injection and examination Image acquisitions : 1 to 3 h<br />
Where there is renal impairment or obstruction, delayed views<br />
may be needed (6 to 24 hours respectively)<br />
Availability From stock<br />
Number of radiolabelled preparations per kit 5<br />
32 | <strong>IBA</strong> |<br />
IMPORTANT : Read package leaflet before using the kit<br />
“Availability of the products, in the different countries, according to the registration status”