...................................................................................................................................................................<br />

Single-phased GRID-CONNECTED INVERTERS<br />

...................................................................................................................................................................<br />

Kaco Powador 02 Series<br />

Great flexibility, simple installation<br />

New current sensor<br />

<strong>The</strong> new current sensor of the Kaco Powador 02 series<br />

enables more precise control and better MPP tracking.<br />

<strong>The</strong> <strong>inverters</strong> <strong>with</strong> electrical isolation satisfy <strong>with</strong> their<br />

effortless installation, highest efficiency as well as optimal<br />

operation by means of thin-film <strong>modules</strong>.<br />

Effortless installation<br />

<strong>The</strong> connections are situated on their own PCB <strong>with</strong>in<br />

the casing and can be connected easily. For a faster and<br />

easier wiring, all communication connections are<br />

mounted separately on a PCB. A DC circuit breaker is<br />

integrated into the device.<br />

Highest efficiency<br />

With an efficiency of 96 %, the<strong>inverters</strong>oftheKaco<br />

Powador 02 series are among the top-rated of their<br />

<strong>The</strong> integrated transformer of the Powador 02 series ensures<br />

electrical isolation from the mains, which allows the<br />

use of thin-film <strong>modules</strong> <strong>with</strong>out any problems.<br />

class. Due to the electrical isolation, the devices can be<br />

installed even in places that would be impossible for<br />

devices <strong>with</strong>out transformers. <strong>The</strong> wide input voltage<br />

range makes the devices extremely flexible.<br />

Advantages in brief<br />

n International <strong>inverters</strong> for 16 countries<br />

n New current sensor<br />

n Electrical isolation<br />

n Simple installation<br />

n High efficiency<br />

n Simple wiring<br />

n Optimal for thin-film <strong>modules</strong><br />

n Display of earthing status of the PV generator<br />

With an efficiency of 96 %, the <strong>inverters</strong> of the Kaco Powador<br />

02 series are among the top-rated of their class.