Installation guide<br />

VertiQ ®<br />

<strong>System</strong> T, <strong>System</strong> <strong>HAT</strong><br />

Impact-resistant and high impact-resistant acoustic wall panel solutions<br />

CI/SfB<br />

(35)<br />

Sm1<br />

January 2012


2<br />

VertiQ ® – <strong>System</strong> T, <strong>System</strong> <strong>HAT</strong><br />

Contents<br />

<strong>System</strong> selection . . . . . . . . . . . . . . . . . . . . 3<br />

Edges and sizes . . . . . . . . . . . . . . . . . . . . . 3<br />

<strong>System</strong> T (impact-resistant)<br />

Components . . . . . . . . . . . . . . . . . . . . . . . 4<br />

Mounting diagrams . . . . . . . . . . . . . . . . . . 4<br />

Single-panel height solutions . . . . . . . . . . . 5<br />

Multiple-panel height solutions . . . . . . . . . 6<br />

1. Perimeter trim . . . . . . . . . . . . . . . . . . . . 7<br />

2. T fixing brackets and<br />

supporting brackets. . . . . . . . . . . . . . . . 8<br />

3. Wall panels and<br />

horizontal intermediate profiles . . . . . . . 9<br />

4. Vertical intermediate profiles . . . . . . . . 11<br />

<strong>System</strong> <strong>HAT</strong> (high impact-resistant)<br />

Components . . . . . . . . . . . . . . . . . . . . . . 12<br />

Mounting diagrams . . . . . . . . . . . . . . . . . 12<br />

5. Perimeter trim . . . . . . . . . . . . . . . . . . . 13<br />

6. Wall panels and<br />

horizontal intermediate profiles . . . . . . 14<br />

7. Vertical intermediate profiles . . . . . . . . 15<br />

For information about storage, handling, service integration and special requirements, this system installation guide should be read and used in<br />

conjunction with “<strong>Rockfon</strong> General Guidelines for Installation”.<br />

<strong>System</strong> T<br />

<strong>System</strong> <strong>HAT</strong><br />

Installation shows 1200 x 1200mm layout at top<br />

and 2700 x 1200mm at bottom.


VertiQ ® – <strong>System</strong> T, <strong>System</strong> <strong>HAT</strong><br />

<strong>System</strong> selection<br />

VertiQ panels are tough and durable in their<br />

own right, however overall system impact<br />

resistance will be determined by the type of<br />

installation system chosen.<br />

Contact <strong>Rockfon</strong> for further information and<br />

advice about impact resistance.<br />

Edges and sizes<br />

VertiQ A24 – <strong>System</strong> T<br />

VertiQ edges and panel dimensions<br />

M = Module size<br />

A24 = M minus 8 mm (M-8 mm)<br />

A <strong>HAT</strong> = M minus 28 mm (M-28 mm)<br />

VertiQ panels<br />

<strong>System</strong> T: Impact-resistant solution,<br />

40 mm thick VertiQ A24 wall panels can be<br />

installed using J channel perimeter trims and<br />

standard 38 mm deep T24 tees as<br />

intermediate profiles fastened directly to the<br />

wall using T fixing brackets and supporting<br />

brackets (when needed).<br />

<strong>System</strong> <strong>HAT</strong>: High impact-resistant solution,<br />

according to DIN 18 032-3 for wall panels<br />

or Class 1A according to EN 13964 annex D<br />

for ceilings<br />

In order to achieve high impact resistance<br />

against, for example, balls in sports halls,<br />

40 mm thick VertiQ A <strong>HAT</strong> wall panels should<br />

be installed using 1 mm thick steel <strong>System</strong> <strong>HAT</strong><br />

profiles fixed directly to the wall.<br />

Edge Module size* (mm) Exact size* (mm) Product code<br />

A24 1200 x 1200 x 40 1192 x 1192 x 40 ##<br />

A24 2700 x 1200 x 40 2692 x 1192 x 40 ##<br />

A <strong>HAT</strong> 1200 x 1200 x 40 1172 x 1172 x 40 ##<br />

A <strong>HAT</strong> 2700 x 1200 x 40 2672 x 1172 x 40 ##<br />

* For other dimensions, please contact <strong>Rockfon</strong>.<br />

40 mm<br />

VertiQ A <strong>HAT</strong> – <strong>System</strong> <strong>HAT</strong><br />

Important<br />

• Use mounting screws/methods appropriate<br />

for the wall material.<br />

• Ensure that the wall is smooth and level.<br />

Any leveling correction must be done before<br />

any installation begins.<br />

• For ”high impact-resistant” solutions using<br />

<strong>System</strong> <strong>HAT</strong>, VertiQ panels must be mounted<br />

directly on the wall without any gap behind<br />

them.<br />

3


4<br />

VertiQ ® – <strong>System</strong> T<br />

40 mm deep J channel perimeter trims and<br />

38 mm deep T24 tees as intermediate vertical<br />

and horizontal profiles are used for <strong>System</strong> T.<br />

J channel perimeter trims are fastened with<br />

screws, together with SMF clips where<br />

needed. For multiple-panel installations, both<br />

horizontal and vertical T24 intermediate<br />

Components<br />

profiles clip into place using T fixing brackets<br />

mounted directly to the wall. Supporting<br />

brackets are also required for multiple-height<br />

or off-floor/base support installations. Total<br />

installation depth is 40 mm.<br />

� � � � � �<br />

Wall panels Perimeter trim Intermediate profiles T fixing bracket Supporting bracket Clip<br />

VertiQ A24 3000 mm long<br />

40 mm J channel,<br />

25 mm wide-side and<br />

13 mm narrow-side<br />

Perimeter trim, bottom – for multiple-height<br />

installations resting on the floor or base support,<br />

use a M-4 mm measure between the bottom<br />

J channel perimeter trim and first horizontal T24<br />

intermediate profiles. This is to ensure the VertiQ<br />

top edges are properly covered by T24 front<br />

capping. All further vertical levels will use<br />

standard M measure distance.<br />

Mounting diagrams<br />

1200 x 1200<br />

400<br />

mm<br />

600 mm<br />

3000 mm long<br />

38 mm deep T24 tees<br />

2700 x 1200<br />

600 mm 1500 mm 600 mm<br />

950 mm<br />

950 mm<br />

400<br />

mm<br />

Rear view of installation<br />

seen from ’inside’ the wall.<br />

for use with<br />

38 mm deep T24 tees<br />

(patent pending)<br />

Supporting bracket – these provide required<br />

bottom support to panels within a multipleheight<br />

or off-floor/base support installation.<br />

They are mounted so the underside is 4 mm<br />

above the module axis line (which the T fixing<br />

bracket channels are centred on) so the panels<br />

come to rest upon them (see the diagram on<br />

page 6).<br />

15x35x50 mm SMF clip<br />

SMF clip – for use when the top J channel<br />

perimeter trim needs to be installed last,<br />

offering demountability.<br />

2700 x 1200<br />

1200 x 1200<br />

600 mm<br />

2700 x 1200<br />

400<br />

mm<br />

400<br />

mm<br />

400<br />

mm<br />

600 mm 1500 mm 600 mm<br />

600 mm<br />

1200 mm<br />

900 mm<br />

400<br />

mm<br />

600 mm<br />

1500 mm 600 mm<br />

400<br />

mm<br />

400<br />

mm


VertiQ ® – <strong>System</strong> T<br />

Single-panel high solutions<br />

1. Top J channel fixed wide-side to the wall with SMF clip, min. 14 mm<br />

distance to the ceiling should remain.<br />

Insert the top J channel perimeter trim into the SMF clips, then lift it up<br />

14 mm to allow the top edge of the panel to fit in. When all the panels<br />

are in place, the top J channel slides back down to cover the top edges.<br />

Vertical T24 intermediate profiles clicked into T fixing brackets should be<br />

installed before lowering the top J channel perimeter trim.<br />

1<br />

wall<br />

wall<br />

25 mm<br />

M<br />

M-4 mm<br />

wall<br />

Bottom J channel perimeter trim:<br />

1. supported by<br />

scu�-resistant base support<br />

40 mm<br />

13 mm<br />

25 mm<br />

25 mm<br />

13 mm<br />

VertiQ panel<br />

top J channel<br />

min. 14 mm<br />

under the ceiling<br />

13 mm 14 mm<br />

scu�-resistant base support,<br />

e.g. solid timber<br />

bottom J channel perimeter trim<br />

�xed 25 mm wide edge to the wall<br />

scu�-resistant baseboard,<br />

e.g. solid timber<br />

top J channel perimeter trim<br />

�xed wide-side to the wall<br />

with SMF clip<br />

VertiQ panel<br />

SMF clip<br />

�xed to the wall<br />

2. unsupported, above the �oor,<br />

with supporting brackets inside<br />

wall<br />

25 mm<br />

40 mm<br />

13 mm<br />

2. Top J channel fixed narrow-side to the wall with SMF clip, can be<br />

mounted directly under the ceiling.<br />

Insert the top J channel perimeter trim into the SMF clips, then the top<br />

edge of the VertiQ panel into the top J channel perimeter trim so the<br />

bottom edge can pass over and set down into the bottom J channel<br />

perimeter trim. Vertical T24 intermediate profiles are installed as the<br />

final step using the same motion as used for the panels.<br />

VertiQ panel<br />

2<br />

wall<br />

15x35x50 mm<br />

supporting brackets<br />

inside bottom J channel<br />

�xed to the wall<br />

M<br />

M-14 mm<br />

wall<br />

bottom J channel perimeter trim<br />

�xed 25 mm wide edge to the wall<br />

13 mm<br />

25 mm<br />

13 mm<br />

3. supported by the �oor<br />

wall<br />

25 mm<br />

scu�-resistant base support,<br />

e.g. solid timber<br />

25 mm<br />

40 mm<br />

13 mm<br />

top J channel perimeter trim<br />

�xed 13 mm narrow-side to the wall<br />

with SMF clip<br />

VertiQ panel<br />

SMF clip<br />

�xed to the wall<br />

VertiQ panel<br />

bottom J channel perimeter trim<br />

�xed 25 mm wide edge to the wall<br />

5


6<br />

VertiQ ® – <strong>System</strong> T<br />

Multi-panel high solutions<br />

600 mm<br />

300 mm<br />

wall<br />

M-4 mm<br />

M<br />

M<br />

M-8 mm M-8 mm<br />

M-8 mm<br />

400 mm 400 mm<br />

300 mm<br />

T �xing bracket,<br />

channel centred on the axis<br />

wall<br />

wall<br />

wall<br />

VertiQ 1200x1200 - 1 supporting bracket<br />

VertiQ 2700x1200 vertical - 2 supporting brackets<br />

VertiQ 2700x1200 horizontal - 3 supporting brackets<br />

supporting bracket for 2700x1200 vertical and<br />

horizontal, align base 4 mm above axis<br />

600 mm<br />

25 mm<br />

25 mm<br />

4 mm<br />

40 mm<br />

40 mm<br />

13 mm<br />

13 mm<br />

4 mm<br />

top J channel perimeter trim<br />

�xed wide-side to the wall<br />

VertiQ panel<br />

supporting bracket �xed to<br />

the wall 4 mm above axis<br />

T �xing bracket �xed to the wall,<br />

channel centred on the axis<br />

horizontal T24 intermediate pro�le<br />

clicked into T Fixing bracket<br />

VertiQ panel<br />

VertiQ panel<br />

base J channel perimeter trim<br />

�xed wide-side to the wall<br />

supporting bracket for 2700x1200 vertical and<br />

horizontal, align base 4 mm above axis<br />

supporting bracket for 1200x1200 and 2700x1200 horizontal,<br />

align base 4 mm above axis and at panel-width centre<br />

300 mm<br />

panel = M-8 mm<br />

M = 2700 mm or 1200 mm


1. Perimeter trim<br />

1.1 Mark out all the axes for perimeter trims and intermediate profiles at Module (M) measures.<br />

For the bottom row of panels, use M-4 mm up from the bottom J channel perimter trim.<br />

every 400 mm within 1200 mm<br />

VertiQ ® – <strong>System</strong> T<br />

1.4<br />

1.2 Top and side perimeter trims affixed 25 mm<br />

wide edge to the wall.<br />

30 mm<br />

1.2<br />

every 400 mm within 1200 mm<br />

30 mm<br />

30 mm<br />

every 300 mm<br />

3.7<br />

1.4 Bottom perimeter trim resting on the floor or<br />

other solid base support material.<br />

Module (M)<br />

Module (M)<br />

Module (M-4 mm)<br />

1.3 Side perimeter trim affixed 25 mm wide edge to<br />

the wall, top perimeter trim affixed 13 mm<br />

narrow edge to the wall with SMF clip. This<br />

method allows for demounting of the top trim.<br />

support bracket at<br />

wall panel centre,<br />

1200 mm and<br />

2700 mm horizontal<br />

every 450 mm within 2700 mm<br />

30 mm<br />

400 mm in from both<br />

left and right edges,<br />

all 2700 mm panels<br />

1.5 Bottom perimeter trim floating above the floor<br />

requires the use of supporting brackets.<br />

30 mm<br />

3.8<br />

30 mm<br />

every 450 mm within 2700 mm<br />

Important<br />

3.9<br />

1.3<br />

1.5<br />

• Use mounting screws/methods<br />

appropriate for the wall material.<br />

• Use a sharp-bladed saw to carefully<br />

achieve neat corner joints.<br />

• Placing an internal support, e.g.<br />

40 mm thick wood block, inside the<br />

perimeter trim will reduce bending /<br />

damage when cutting.<br />

• Use supporting brackets to support<br />

multi-height installation panels and<br />

bottom perimeter trim not resting<br />

on the floor/base support;<br />

For off-floor installations,<br />

consideration should be given to using<br />

a scuff-resistant skirting or base<br />

support between the floor and<br />

bottom perimeter trim. This will<br />

reduce the likelihood of damage from<br />

shoes, luggage, vaccuum cleaners or<br />

other floor-level risks and help avoid<br />

ball or human contact with any lowlying<br />

perimeter trim corners.<br />

7


8<br />

VertiQ ® – <strong>System</strong> T<br />

2. T fixing brackets and<br />

supporting brackets<br />

T fixing brackets and supporting brackets<br />

are required to:<br />

• prevent accidental removal of intermediate<br />

profiles;<br />

• provide enough support for each panel<br />

separately in multiple-height installations;<br />

Consumption guide (pieces per panel)<br />

Panel size<br />

(mm)<br />

Panel<br />

orientation<br />

2700 x 1200 Vertical<br />

2700 x 1200 Horizontal<br />

1200 x 1200 –<br />

300 mm<br />

600 mm<br />

300 mm<br />

Module<br />

1200 mm<br />

Supporting brackets<br />

(off-floor/base support or multipanel<br />

height installations only)<br />

2:<br />

400 mm in from both<br />

left and right edges<br />

3:<br />

400 mm in from both<br />

left and right edges,<br />

one at panel-centre<br />

1:<br />

600 mm in from both<br />

left and right edges<br />

(panel-centre)<br />

• make a secure yet demountable installation<br />

– intermediate profiles can be removed from<br />

their T fixing brackets by using a special teeremoval<br />

tool, as long as their positions are<br />

known.<br />

Remember to follow recommended guidelines<br />

for quantity and positioning of both T fixing<br />

brackets and supporting brackets.<br />

Module<br />

1200 mm<br />

600 mm 1200 mm 600 mm<br />

T fixing brackets,<br />

horizontal<br />

0 if a single-panel height installation,<br />

2 at each additional panel junction:<br />

300 mm in from both<br />

left and right edges<br />

0 if a single-panel height installation,<br />

2 at each additional panel junction:<br />

600 mm in from both<br />

left and right edges<br />

0 if a single-panel height installation,<br />

2 at each additional panel junction:<br />

300 mm in from both<br />

left and right edges<br />

Important<br />

Creating a demountable solution depends on<br />

knowing where all the T fixing brackets are<br />

located after installation is completed.<br />

An installation diagram clearly showing the<br />

positions of all T fixing brackets should be<br />

made and archived. This will enable easy<br />

location of these components for any<br />

subsequent maintenance.<br />

2.1 Placement of all T fixing brackets and supporting brackets should be measured out and mounted before any panel installation begins. Doing so will greatly reduce<br />

installation time. Ensure that all brackets line up – T fixing brackets’ channel on the module axis, supporting brackets’ underside 4 mm above it.<br />

T fixing<br />

brackets<br />

Supporting<br />

brackets<br />

T fixing brackets,<br />

vertical<br />

0 if a single-panel wide installation,<br />

2 at each additional panel junction:<br />

600 mm in from both<br />

top and bottom edges<br />

0 if a single-panel wide installation,<br />

1 at each additional panel junction:<br />

600 mm in from both<br />

top and bottom edges (panel-centre)<br />

0 if a single-panel wide installation,<br />

1 at each additional panel junction:<br />

600 mm in from both<br />

top and bottom edges (panel-centre)<br />

Installation of VertiQ panels should only be done using components supplied by <strong>Rockfon</strong>. Components are sold separately. Failure to follow these instruction will void any warranty.


VertiQ ® – <strong>System</strong> T<br />

3. Wall panels<br />

These instructions cover both single and<br />

multiple-height installations. For multiple, the<br />

terms ’upper’ and ’lower’ refer respectively to<br />

the uppermost and lowermost panels.<br />

3.1 Angle an ’upper’ panel into the top J channel perimeter trim, then flat<br />

against the wall. Ensure there is sufficient trim overlapping the panel top,<br />

then slide it carefully into the vertical J channel perimeter trim.<br />

3.3 Angle a ’lower’ panel into the bottom J channel perimeter trim, then flat<br />

against the wall. Slide it carefully into the vertical J channel perimeter trim.<br />

3.5 Install any intermediate panels, working from ’upper’ to ’lower’.<br />

They should sit securely in place via supporting bracket(s) and perimeter<br />

trim – see diagram on page 6.<br />

Start installing VertiQ wall panels working<br />

inward from the outside / perimeter panels,<br />

both left and right. Ensure that all outside /<br />

perimeter panel edges are securely under their<br />

perimeter trims.<br />

As outside / perimeter panels are installed,<br />

cover their horizontal joints with 38 mm deep<br />

tees cut to exactly M-12 mm (see diagram on<br />

page 11). This secures the panel enough to<br />

continue safely working inward.<br />

3.2 The bottom of all multiple-height installation panels should rest securely on<br />

their supporting bracket(s) – see diagram on page 6.<br />

3.4 When required, remember to use supporting brackets mounted inside the<br />

bottom J channel perimeter trim.<br />

3.6 Cover the horizontal joints between panels by clicking T24 profiles into the<br />

T fixing brackets, then slide it carefully under the perimeter trim edge.<br />

These horizontal tees must be cut to an exact dimension of M-12 mm.<br />

9


10<br />

VertiQ ® – <strong>System</strong> T<br />

3.7 External corner – two vertical J channel perimeter trims are fastened to<br />

each other every 300 mm and 30 mm from each end. The wall-mounted<br />

perimeter trim is fixed 25 mm wide-edge to the wall, also every 300 mm.<br />

3.9 Perimeter trim finishing around a door or window should always be done<br />

with J channel perimeter trims mounted 25 mm wide-edge to the wall,<br />

affixed every 300 mm and 30 mm from all ends. To minimize panel waste,<br />

measure and cut carefully while ensuring adequate perimeter trim overlap.<br />

3.11 Install all remaining intermediate panels as described on page 9, working<br />

from the top downwards. During installation, cover all horizontal joints with<br />

T24 profiles by clicking them into the T fixing brackets. When the entire<br />

installation is fitted with VertiQ panels, the final step is covering all the<br />

vertical joints with long tees clicked into T fixing brackets (see next section).<br />

3.8 Internal corner – one vertical J channel perimeter trim is mounted a<br />

distance of 40 mm from the corner, 25 mm wide-edge affixed to the wall<br />

every 300 mm. This allows a VertiQ panel to slide into the corner behind it.<br />

3.7<br />

3.10 Cover all remaining horizontal joints between panels by clicking<br />

T24 profiles into the T fixing brackets. Horizontal profiles should be cut to<br />

an exact dimension of M-12 mm. Ensure the outter ends of the horizontal<br />

tees are covered by the perimeter trims.<br />

Important<br />

The standard locking connectors at each end of a T24 profile are not<br />

needed when installing VertiQ A24 in <strong>System</strong> T. Do not include them<br />

in any measurements, simply cut them off.<br />

3.8<br />

3.9


VertiQ ® – <strong>System</strong> T<br />

4. Vertical intermediate profiles<br />

4.2 All VertiQ A24 panels and tees installed.<br />

M -12 mm<br />

M -12 mm M -12 mm<br />

M<br />

M = Module<br />

M M<br />

Wall<br />

4.1 When the entire surface is covered with wall panels, cover all the vertical joints<br />

with long T24 profiles clicked into the T fixing brackets. These vertical tees must<br />

be cut to an exact length of X-12 mm, where X is the installation height.<br />

Ensure the ends of all horizontal tees are covered by the vertical tees, and that<br />

both ends of the vertical tees are sufficiently covered by the top and bottom<br />

perimeter trims. Use additional T fixing brackets to connect vertical profile<br />

extensions when required.<br />

11


12<br />

40 mm deep <strong>HAT</strong> profiles, made from 1.0 mm thick steel, are used as vertical and horizontal<br />

profiles in the VertiQ high impact resistant <strong>System</strong> <strong>HAT</strong>. 40 mm deep J channels, or alternatively<br />

the same <strong>HAT</strong> profiles, both made of 1.0 mm thick steel are used as perimeter trims. All the<br />

profiles are affixed directly to the wall with appropriate fixings, suitable to the wall material.<br />

Total installation depth is 40 mm.<br />

Components<br />

� � �<br />

Wall<br />

VertiQ ® – <strong>System</strong> <strong>HAT</strong><br />

Wall panels Perimeter trim Intermediate profiles<br />

VertiQ <strong>HAT</strong> 2700 mm long,<br />

1 mm thick<br />

40 mm deep J channel,<br />

25 mm wide-side and<br />

13 mm narrow-side<br />

Mounting diagrams<br />

M = Module<br />

M<br />

M<br />

M M M<br />

M-28 mm<br />

M-28 mm<br />

M-28 mm<br />

M-28 mm<br />

28 mm<br />

28 mm<br />

28 mm<br />

50 mm 50 mm 50 mm 50 mm<br />

50 mm<br />

M-12 mm M M<br />

M-12 mm<br />

28 mm 28 mm 28 mm<br />

M-28 mm<br />

M-28 mm M-28 mm M-28 mm<br />

Wall<br />

1200 x 1200<br />

Wall<br />

2700 mm long,<br />

1 mm thick <strong>HAT</strong><br />

(alternative)<br />

M-12 mm M M<br />

M-12 mm<br />

M-28 mm<br />

28 mm<br />

M-28 mm<br />

28 mm<br />

M-28 mm<br />

28 mm<br />

M-28 mm<br />

M M M<br />

1148 mm and<br />

2700 mm long,<br />

1 mm thick <strong>HAT</strong><br />

M-28 mm<br />

M-28 mm<br />

M-28 mm<br />

M-28 mm<br />

28 mm<br />

28 mm<br />

28 mm<br />

50 mm 50 mm 50 mm 2700 x 50 1200 mm<br />

50 mm<br />

Wall<br />

Rear view of installation<br />

seen from 'inside' the wall.<br />

2700 x 1200<br />

1200 x 1200<br />

2700 x 1200


VertiQ ® – <strong>System</strong> <strong>HAT</strong><br />

5. Perimeter trim<br />

Module (M)<br />

5.1 Mark out all the axes for perimeter trims and intermediate profiles.<br />

5.2 Top and side perimeter trims, 25 mm wide edge<br />

to the wall.<br />

30 mm<br />

30 mm<br />

30 mm<br />

5.3 Bottom perimeter trim resting on the floor or<br />

other solid base support material.<br />

Important<br />

M (using <strong>HAT</strong> top trim)<br />

M-12 (using J channel top trim)<br />

M (using <strong>HAT</strong> bottom trim)<br />

M-12 (using J channel bottom trim)<br />

• Use mounting screws/methods appropriate<br />

for the wall material.<br />

• Use a sharp-bladed saw to carefully achieve<br />

neat corner joints.<br />

• Placing an internal support, e.g. 40 mm<br />

thick wood block, inside the perimeter trim<br />

will reduce bending / damage when cutting.<br />

For off-floor installations, consideration should<br />

be given to using a scuff-resistant skirting or<br />

base support between the floor and bottom<br />

perimeter trim. This will reduce the likelihood<br />

of damage from shoes, luggage, vacuum<br />

cleaners or other floor-level risks and help<br />

avoid ball or human contact with any lowlying<br />

perimeter trim corners.<br />

13


14<br />

VertiQ ® – <strong>System</strong> <strong>HAT</strong><br />

6. Wall panels and horizontal intermediate profiles<br />

6.1 Start installing VertiQ wall panels<br />

working inward from the outside<br />

/ perimeter panels, both left and<br />

right, bottom panels first. Ensure<br />

that all outside / perimeter panel<br />

edges are securely under their<br />

perimeter trims.<br />

6.2 For multiple-height installations, place the next<br />

panel above and cover the horizontal joint(s)<br />

between panels with a 40 mm <strong>HAT</strong> profile the<br />

exact length of M-52 mm (see diagram on<br />

page 15), affixed at panel centre (figure 6.4).<br />

Ensure that the panel edges are covered by<br />

perimeter trims (J or <strong>HAT</strong>) and intermediate<br />

<strong>HAT</strong> profiles.<br />

6.4 Install all the remaining panels and horizontal <strong>HAT</strong> profiles, working toward the middle.<br />

6.3 All outside / perimeter panels installed with horizontal <strong>HAT</strong> profiles.<br />

52 mm<br />

Cover all the horizontal joints with <strong>HAT</strong> profiles<br />

centred on the panel width leaving a 52 mm gap<br />

between them for the vertical <strong>HAT</strong> profile.


VertiQ ® – <strong>System</strong> <strong>HAT</strong><br />

7. Vertical intermediate profiles<br />

M = Module<br />

50 mm<br />

vertical <strong>HAT</strong><br />

7.1 All VertiQ panels and <strong>HAT</strong> profiles installed.<br />

Wall<br />

M-28 mm<br />

VertiQ panel<br />

M<br />

M-52 mm<br />

horizontal <strong>HAT</strong><br />

50 mm<br />

vertical <strong>HAT</strong><br />

The vertical <strong>HAT</strong> profile edges should meet cleanly<br />

against the horizontal <strong>HAT</strong> profile edges, not<br />

overlap them.<br />

15


ACTIVATE YOUR CEILING<br />

<strong>Rockfon</strong>® develops intelligent ceiling and wall solutions which actively address<br />

a number of important issues in modern buildings and renovation projects.<br />

<strong>Rockfon</strong> products are known for their design, aesthetics and ease of<br />

installation, coupled with the key performance features of superior<br />

fire resistance and acoustics.<br />

This ensures that our acoustic solutions are among the highest performing,<br />

most cost effective and time efficient in today’s interiors market.<br />

This comprehensive portfolio from <strong>Rockfon</strong> enables our customers to<br />

actively add value to the construction process, by ultimately creating superior<br />

interior environments.<br />

That is why we say “ACTIVATE YOUR CEILING”.<br />

<strong>Rockfon</strong><br />

A trading division of Rockwool Limited<br />

26-28 Hammersmith Grove<br />

London<br />

W6 7HA<br />

Tel: 020 8222 7457<br />

Fax: 020 8222 7458<br />

www.rockfon.co.uk<br />

All colour codes mentioned are based on the NCS - Natural Colour<br />

<strong>System</strong> ®© property of and used on licence from NCS Colour AB,<br />

Stockholm 2010.<br />

Subject to alterations in range and product technology without prior<br />

notice. <strong>Rockfon</strong> accepts no responsibility for printing errors.<br />

01.2012

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!