VertiQ® System T, System HAT - Rockfon
VertiQ® System T, System HAT - Rockfon
VertiQ® System T, System HAT - Rockfon
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Installation guide<br />
VertiQ ®<br />
<strong>System</strong> T, <strong>System</strong> <strong>HAT</strong><br />
Impact-resistant and high impact-resistant acoustic wall panel solutions<br />
CI/SfB<br />
(35)<br />
Sm1<br />
January 2012
2<br />
VertiQ ® – <strong>System</strong> T, <strong>System</strong> <strong>HAT</strong><br />
Contents<br />
<strong>System</strong> selection . . . . . . . . . . . . . . . . . . . . 3<br />
Edges and sizes . . . . . . . . . . . . . . . . . . . . . 3<br />
<strong>System</strong> T (impact-resistant)<br />
Components . . . . . . . . . . . . . . . . . . . . . . . 4<br />
Mounting diagrams . . . . . . . . . . . . . . . . . . 4<br />
Single-panel height solutions . . . . . . . . . . . 5<br />
Multiple-panel height solutions . . . . . . . . . 6<br />
1. Perimeter trim . . . . . . . . . . . . . . . . . . . . 7<br />
2. T fixing brackets and<br />
supporting brackets. . . . . . . . . . . . . . . . 8<br />
3. Wall panels and<br />
horizontal intermediate profiles . . . . . . . 9<br />
4. Vertical intermediate profiles . . . . . . . . 11<br />
<strong>System</strong> <strong>HAT</strong> (high impact-resistant)<br />
Components . . . . . . . . . . . . . . . . . . . . . . 12<br />
Mounting diagrams . . . . . . . . . . . . . . . . . 12<br />
5. Perimeter trim . . . . . . . . . . . . . . . . . . . 13<br />
6. Wall panels and<br />
horizontal intermediate profiles . . . . . . 14<br />
7. Vertical intermediate profiles . . . . . . . . 15<br />
For information about storage, handling, service integration and special requirements, this system installation guide should be read and used in<br />
conjunction with “<strong>Rockfon</strong> General Guidelines for Installation”.<br />
<strong>System</strong> T<br />
<strong>System</strong> <strong>HAT</strong><br />
Installation shows 1200 x 1200mm layout at top<br />
and 2700 x 1200mm at bottom.
VertiQ ® – <strong>System</strong> T, <strong>System</strong> <strong>HAT</strong><br />
<strong>System</strong> selection<br />
VertiQ panels are tough and durable in their<br />
own right, however overall system impact<br />
resistance will be determined by the type of<br />
installation system chosen.<br />
Contact <strong>Rockfon</strong> for further information and<br />
advice about impact resistance.<br />
Edges and sizes<br />
VertiQ A24 – <strong>System</strong> T<br />
VertiQ edges and panel dimensions<br />
M = Module size<br />
A24 = M minus 8 mm (M-8 mm)<br />
A <strong>HAT</strong> = M minus 28 mm (M-28 mm)<br />
VertiQ panels<br />
<strong>System</strong> T: Impact-resistant solution,<br />
40 mm thick VertiQ A24 wall panels can be<br />
installed using J channel perimeter trims and<br />
standard 38 mm deep T24 tees as<br />
intermediate profiles fastened directly to the<br />
wall using T fixing brackets and supporting<br />
brackets (when needed).<br />
<strong>System</strong> <strong>HAT</strong>: High impact-resistant solution,<br />
according to DIN 18 032-3 for wall panels<br />
or Class 1A according to EN 13964 annex D<br />
for ceilings<br />
In order to achieve high impact resistance<br />
against, for example, balls in sports halls,<br />
40 mm thick VertiQ A <strong>HAT</strong> wall panels should<br />
be installed using 1 mm thick steel <strong>System</strong> <strong>HAT</strong><br />
profiles fixed directly to the wall.<br />
Edge Module size* (mm) Exact size* (mm) Product code<br />
A24 1200 x 1200 x 40 1192 x 1192 x 40 ##<br />
A24 2700 x 1200 x 40 2692 x 1192 x 40 ##<br />
A <strong>HAT</strong> 1200 x 1200 x 40 1172 x 1172 x 40 ##<br />
A <strong>HAT</strong> 2700 x 1200 x 40 2672 x 1172 x 40 ##<br />
* For other dimensions, please contact <strong>Rockfon</strong>.<br />
40 mm<br />
VertiQ A <strong>HAT</strong> – <strong>System</strong> <strong>HAT</strong><br />
Important<br />
• Use mounting screws/methods appropriate<br />
for the wall material.<br />
• Ensure that the wall is smooth and level.<br />
Any leveling correction must be done before<br />
any installation begins.<br />
• For ”high impact-resistant” solutions using<br />
<strong>System</strong> <strong>HAT</strong>, VertiQ panels must be mounted<br />
directly on the wall without any gap behind<br />
them.<br />
3
4<br />
VertiQ ® – <strong>System</strong> T<br />
40 mm deep J channel perimeter trims and<br />
38 mm deep T24 tees as intermediate vertical<br />
and horizontal profiles are used for <strong>System</strong> T.<br />
J channel perimeter trims are fastened with<br />
screws, together with SMF clips where<br />
needed. For multiple-panel installations, both<br />
horizontal and vertical T24 intermediate<br />
Components<br />
profiles clip into place using T fixing brackets<br />
mounted directly to the wall. Supporting<br />
brackets are also required for multiple-height<br />
or off-floor/base support installations. Total<br />
installation depth is 40 mm.<br />
� � � � � �<br />
Wall panels Perimeter trim Intermediate profiles T fixing bracket Supporting bracket Clip<br />
VertiQ A24 3000 mm long<br />
40 mm J channel,<br />
25 mm wide-side and<br />
13 mm narrow-side<br />
Perimeter trim, bottom – for multiple-height<br />
installations resting on the floor or base support,<br />
use a M-4 mm measure between the bottom<br />
J channel perimeter trim and first horizontal T24<br />
intermediate profiles. This is to ensure the VertiQ<br />
top edges are properly covered by T24 front<br />
capping. All further vertical levels will use<br />
standard M measure distance.<br />
Mounting diagrams<br />
1200 x 1200<br />
400<br />
mm<br />
600 mm<br />
3000 mm long<br />
38 mm deep T24 tees<br />
2700 x 1200<br />
600 mm 1500 mm 600 mm<br />
950 mm<br />
950 mm<br />
400<br />
mm<br />
Rear view of installation<br />
seen from ’inside’ the wall.<br />
for use with<br />
38 mm deep T24 tees<br />
(patent pending)<br />
Supporting bracket – these provide required<br />
bottom support to panels within a multipleheight<br />
or off-floor/base support installation.<br />
They are mounted so the underside is 4 mm<br />
above the module axis line (which the T fixing<br />
bracket channels are centred on) so the panels<br />
come to rest upon them (see the diagram on<br />
page 6).<br />
15x35x50 mm SMF clip<br />
SMF clip – for use when the top J channel<br />
perimeter trim needs to be installed last,<br />
offering demountability.<br />
2700 x 1200<br />
1200 x 1200<br />
600 mm<br />
2700 x 1200<br />
400<br />
mm<br />
400<br />
mm<br />
400<br />
mm<br />
600 mm 1500 mm 600 mm<br />
600 mm<br />
1200 mm<br />
900 mm<br />
400<br />
mm<br />
600 mm<br />
1500 mm 600 mm<br />
400<br />
mm<br />
400<br />
mm
VertiQ ® – <strong>System</strong> T<br />
Single-panel high solutions<br />
1. Top J channel fixed wide-side to the wall with SMF clip, min. 14 mm<br />
distance to the ceiling should remain.<br />
Insert the top J channel perimeter trim into the SMF clips, then lift it up<br />
14 mm to allow the top edge of the panel to fit in. When all the panels<br />
are in place, the top J channel slides back down to cover the top edges.<br />
Vertical T24 intermediate profiles clicked into T fixing brackets should be<br />
installed before lowering the top J channel perimeter trim.<br />
1<br />
wall<br />
wall<br />
25 mm<br />
M<br />
M-4 mm<br />
wall<br />
Bottom J channel perimeter trim:<br />
1. supported by<br />
scu�-resistant base support<br />
40 mm<br />
13 mm<br />
25 mm<br />
25 mm<br />
13 mm<br />
VertiQ panel<br />
top J channel<br />
min. 14 mm<br />
under the ceiling<br />
13 mm 14 mm<br />
scu�-resistant base support,<br />
e.g. solid timber<br />
bottom J channel perimeter trim<br />
�xed 25 mm wide edge to the wall<br />
scu�-resistant baseboard,<br />
e.g. solid timber<br />
top J channel perimeter trim<br />
�xed wide-side to the wall<br />
with SMF clip<br />
VertiQ panel<br />
SMF clip<br />
�xed to the wall<br />
2. unsupported, above the �oor,<br />
with supporting brackets inside<br />
wall<br />
25 mm<br />
40 mm<br />
13 mm<br />
2. Top J channel fixed narrow-side to the wall with SMF clip, can be<br />
mounted directly under the ceiling.<br />
Insert the top J channel perimeter trim into the SMF clips, then the top<br />
edge of the VertiQ panel into the top J channel perimeter trim so the<br />
bottom edge can pass over and set down into the bottom J channel<br />
perimeter trim. Vertical T24 intermediate profiles are installed as the<br />
final step using the same motion as used for the panels.<br />
VertiQ panel<br />
2<br />
wall<br />
15x35x50 mm<br />
supporting brackets<br />
inside bottom J channel<br />
�xed to the wall<br />
M<br />
M-14 mm<br />
wall<br />
bottom J channel perimeter trim<br />
�xed 25 mm wide edge to the wall<br />
13 mm<br />
25 mm<br />
13 mm<br />
3. supported by the �oor<br />
wall<br />
25 mm<br />
scu�-resistant base support,<br />
e.g. solid timber<br />
25 mm<br />
40 mm<br />
13 mm<br />
top J channel perimeter trim<br />
�xed 13 mm narrow-side to the wall<br />
with SMF clip<br />
VertiQ panel<br />
SMF clip<br />
�xed to the wall<br />
VertiQ panel<br />
bottom J channel perimeter trim<br />
�xed 25 mm wide edge to the wall<br />
5
6<br />
VertiQ ® – <strong>System</strong> T<br />
Multi-panel high solutions<br />
600 mm<br />
300 mm<br />
wall<br />
M-4 mm<br />
M<br />
M<br />
M-8 mm M-8 mm<br />
M-8 mm<br />
400 mm 400 mm<br />
300 mm<br />
T �xing bracket,<br />
channel centred on the axis<br />
wall<br />
wall<br />
wall<br />
VertiQ 1200x1200 - 1 supporting bracket<br />
VertiQ 2700x1200 vertical - 2 supporting brackets<br />
VertiQ 2700x1200 horizontal - 3 supporting brackets<br />
supporting bracket for 2700x1200 vertical and<br />
horizontal, align base 4 mm above axis<br />
600 mm<br />
25 mm<br />
25 mm<br />
4 mm<br />
40 mm<br />
40 mm<br />
13 mm<br />
13 mm<br />
4 mm<br />
top J channel perimeter trim<br />
�xed wide-side to the wall<br />
VertiQ panel<br />
supporting bracket �xed to<br />
the wall 4 mm above axis<br />
T �xing bracket �xed to the wall,<br />
channel centred on the axis<br />
horizontal T24 intermediate pro�le<br />
clicked into T Fixing bracket<br />
VertiQ panel<br />
VertiQ panel<br />
base J channel perimeter trim<br />
�xed wide-side to the wall<br />
supporting bracket for 2700x1200 vertical and<br />
horizontal, align base 4 mm above axis<br />
supporting bracket for 1200x1200 and 2700x1200 horizontal,<br />
align base 4 mm above axis and at panel-width centre<br />
300 mm<br />
panel = M-8 mm<br />
M = 2700 mm or 1200 mm
1. Perimeter trim<br />
1.1 Mark out all the axes for perimeter trims and intermediate profiles at Module (M) measures.<br />
For the bottom row of panels, use M-4 mm up from the bottom J channel perimter trim.<br />
every 400 mm within 1200 mm<br />
VertiQ ® – <strong>System</strong> T<br />
1.4<br />
1.2 Top and side perimeter trims affixed 25 mm<br />
wide edge to the wall.<br />
30 mm<br />
1.2<br />
every 400 mm within 1200 mm<br />
30 mm<br />
30 mm<br />
every 300 mm<br />
3.7<br />
1.4 Bottom perimeter trim resting on the floor or<br />
other solid base support material.<br />
Module (M)<br />
Module (M)<br />
Module (M-4 mm)<br />
1.3 Side perimeter trim affixed 25 mm wide edge to<br />
the wall, top perimeter trim affixed 13 mm<br />
narrow edge to the wall with SMF clip. This<br />
method allows for demounting of the top trim.<br />
support bracket at<br />
wall panel centre,<br />
1200 mm and<br />
2700 mm horizontal<br />
every 450 mm within 2700 mm<br />
30 mm<br />
400 mm in from both<br />
left and right edges,<br />
all 2700 mm panels<br />
1.5 Bottom perimeter trim floating above the floor<br />
requires the use of supporting brackets.<br />
30 mm<br />
3.8<br />
30 mm<br />
every 450 mm within 2700 mm<br />
Important<br />
3.9<br />
1.3<br />
1.5<br />
• Use mounting screws/methods<br />
appropriate for the wall material.<br />
• Use a sharp-bladed saw to carefully<br />
achieve neat corner joints.<br />
• Placing an internal support, e.g.<br />
40 mm thick wood block, inside the<br />
perimeter trim will reduce bending /<br />
damage when cutting.<br />
• Use supporting brackets to support<br />
multi-height installation panels and<br />
bottom perimeter trim not resting<br />
on the floor/base support;<br />
For off-floor installations,<br />
consideration should be given to using<br />
a scuff-resistant skirting or base<br />
support between the floor and<br />
bottom perimeter trim. This will<br />
reduce the likelihood of damage from<br />
shoes, luggage, vaccuum cleaners or<br />
other floor-level risks and help avoid<br />
ball or human contact with any lowlying<br />
perimeter trim corners.<br />
7
8<br />
VertiQ ® – <strong>System</strong> T<br />
2. T fixing brackets and<br />
supporting brackets<br />
T fixing brackets and supporting brackets<br />
are required to:<br />
• prevent accidental removal of intermediate<br />
profiles;<br />
• provide enough support for each panel<br />
separately in multiple-height installations;<br />
Consumption guide (pieces per panel)<br />
Panel size<br />
(mm)<br />
Panel<br />
orientation<br />
2700 x 1200 Vertical<br />
2700 x 1200 Horizontal<br />
1200 x 1200 –<br />
300 mm<br />
600 mm<br />
300 mm<br />
Module<br />
1200 mm<br />
Supporting brackets<br />
(off-floor/base support or multipanel<br />
height installations only)<br />
2:<br />
400 mm in from both<br />
left and right edges<br />
3:<br />
400 mm in from both<br />
left and right edges,<br />
one at panel-centre<br />
1:<br />
600 mm in from both<br />
left and right edges<br />
(panel-centre)<br />
• make a secure yet demountable installation<br />
– intermediate profiles can be removed from<br />
their T fixing brackets by using a special teeremoval<br />
tool, as long as their positions are<br />
known.<br />
Remember to follow recommended guidelines<br />
for quantity and positioning of both T fixing<br />
brackets and supporting brackets.<br />
Module<br />
1200 mm<br />
600 mm 1200 mm 600 mm<br />
T fixing brackets,<br />
horizontal<br />
0 if a single-panel height installation,<br />
2 at each additional panel junction:<br />
300 mm in from both<br />
left and right edges<br />
0 if a single-panel height installation,<br />
2 at each additional panel junction:<br />
600 mm in from both<br />
left and right edges<br />
0 if a single-panel height installation,<br />
2 at each additional panel junction:<br />
300 mm in from both<br />
left and right edges<br />
Important<br />
Creating a demountable solution depends on<br />
knowing where all the T fixing brackets are<br />
located after installation is completed.<br />
An installation diagram clearly showing the<br />
positions of all T fixing brackets should be<br />
made and archived. This will enable easy<br />
location of these components for any<br />
subsequent maintenance.<br />
2.1 Placement of all T fixing brackets and supporting brackets should be measured out and mounted before any panel installation begins. Doing so will greatly reduce<br />
installation time. Ensure that all brackets line up – T fixing brackets’ channel on the module axis, supporting brackets’ underside 4 mm above it.<br />
T fixing<br />
brackets<br />
Supporting<br />
brackets<br />
T fixing brackets,<br />
vertical<br />
0 if a single-panel wide installation,<br />
2 at each additional panel junction:<br />
600 mm in from both<br />
top and bottom edges<br />
0 if a single-panel wide installation,<br />
1 at each additional panel junction:<br />
600 mm in from both<br />
top and bottom edges (panel-centre)<br />
0 if a single-panel wide installation,<br />
1 at each additional panel junction:<br />
600 mm in from both<br />
top and bottom edges (panel-centre)<br />
Installation of VertiQ panels should only be done using components supplied by <strong>Rockfon</strong>. Components are sold separately. Failure to follow these instruction will void any warranty.
VertiQ ® – <strong>System</strong> T<br />
3. Wall panels<br />
These instructions cover both single and<br />
multiple-height installations. For multiple, the<br />
terms ’upper’ and ’lower’ refer respectively to<br />
the uppermost and lowermost panels.<br />
3.1 Angle an ’upper’ panel into the top J channel perimeter trim, then flat<br />
against the wall. Ensure there is sufficient trim overlapping the panel top,<br />
then slide it carefully into the vertical J channel perimeter trim.<br />
3.3 Angle a ’lower’ panel into the bottom J channel perimeter trim, then flat<br />
against the wall. Slide it carefully into the vertical J channel perimeter trim.<br />
3.5 Install any intermediate panels, working from ’upper’ to ’lower’.<br />
They should sit securely in place via supporting bracket(s) and perimeter<br />
trim – see diagram on page 6.<br />
Start installing VertiQ wall panels working<br />
inward from the outside / perimeter panels,<br />
both left and right. Ensure that all outside /<br />
perimeter panel edges are securely under their<br />
perimeter trims.<br />
As outside / perimeter panels are installed,<br />
cover their horizontal joints with 38 mm deep<br />
tees cut to exactly M-12 mm (see diagram on<br />
page 11). This secures the panel enough to<br />
continue safely working inward.<br />
3.2 The bottom of all multiple-height installation panels should rest securely on<br />
their supporting bracket(s) – see diagram on page 6.<br />
3.4 When required, remember to use supporting brackets mounted inside the<br />
bottom J channel perimeter trim.<br />
3.6 Cover the horizontal joints between panels by clicking T24 profiles into the<br />
T fixing brackets, then slide it carefully under the perimeter trim edge.<br />
These horizontal tees must be cut to an exact dimension of M-12 mm.<br />
9
10<br />
VertiQ ® – <strong>System</strong> T<br />
3.7 External corner – two vertical J channel perimeter trims are fastened to<br />
each other every 300 mm and 30 mm from each end. The wall-mounted<br />
perimeter trim is fixed 25 mm wide-edge to the wall, also every 300 mm.<br />
3.9 Perimeter trim finishing around a door or window should always be done<br />
with J channel perimeter trims mounted 25 mm wide-edge to the wall,<br />
affixed every 300 mm and 30 mm from all ends. To minimize panel waste,<br />
measure and cut carefully while ensuring adequate perimeter trim overlap.<br />
3.11 Install all remaining intermediate panels as described on page 9, working<br />
from the top downwards. During installation, cover all horizontal joints with<br />
T24 profiles by clicking them into the T fixing brackets. When the entire<br />
installation is fitted with VertiQ panels, the final step is covering all the<br />
vertical joints with long tees clicked into T fixing brackets (see next section).<br />
3.8 Internal corner – one vertical J channel perimeter trim is mounted a<br />
distance of 40 mm from the corner, 25 mm wide-edge affixed to the wall<br />
every 300 mm. This allows a VertiQ panel to slide into the corner behind it.<br />
3.7<br />
3.10 Cover all remaining horizontal joints between panels by clicking<br />
T24 profiles into the T fixing brackets. Horizontal profiles should be cut to<br />
an exact dimension of M-12 mm. Ensure the outter ends of the horizontal<br />
tees are covered by the perimeter trims.<br />
Important<br />
The standard locking connectors at each end of a T24 profile are not<br />
needed when installing VertiQ A24 in <strong>System</strong> T. Do not include them<br />
in any measurements, simply cut them off.<br />
3.8<br />
3.9
VertiQ ® – <strong>System</strong> T<br />
4. Vertical intermediate profiles<br />
4.2 All VertiQ A24 panels and tees installed.<br />
M -12 mm<br />
M -12 mm M -12 mm<br />
M<br />
M = Module<br />
M M<br />
Wall<br />
4.1 When the entire surface is covered with wall panels, cover all the vertical joints<br />
with long T24 profiles clicked into the T fixing brackets. These vertical tees must<br />
be cut to an exact length of X-12 mm, where X is the installation height.<br />
Ensure the ends of all horizontal tees are covered by the vertical tees, and that<br />
both ends of the vertical tees are sufficiently covered by the top and bottom<br />
perimeter trims. Use additional T fixing brackets to connect vertical profile<br />
extensions when required.<br />
11
12<br />
40 mm deep <strong>HAT</strong> profiles, made from 1.0 mm thick steel, are used as vertical and horizontal<br />
profiles in the VertiQ high impact resistant <strong>System</strong> <strong>HAT</strong>. 40 mm deep J channels, or alternatively<br />
the same <strong>HAT</strong> profiles, both made of 1.0 mm thick steel are used as perimeter trims. All the<br />
profiles are affixed directly to the wall with appropriate fixings, suitable to the wall material.<br />
Total installation depth is 40 mm.<br />
Components<br />
� � �<br />
Wall<br />
VertiQ ® – <strong>System</strong> <strong>HAT</strong><br />
Wall panels Perimeter trim Intermediate profiles<br />
VertiQ <strong>HAT</strong> 2700 mm long,<br />
1 mm thick<br />
40 mm deep J channel,<br />
25 mm wide-side and<br />
13 mm narrow-side<br />
Mounting diagrams<br />
M = Module<br />
M<br />
M<br />
M M M<br />
M-28 mm<br />
M-28 mm<br />
M-28 mm<br />
M-28 mm<br />
28 mm<br />
28 mm<br />
28 mm<br />
50 mm 50 mm 50 mm 50 mm<br />
50 mm<br />
M-12 mm M M<br />
M-12 mm<br />
28 mm 28 mm 28 mm<br />
M-28 mm<br />
M-28 mm M-28 mm M-28 mm<br />
Wall<br />
1200 x 1200<br />
Wall<br />
2700 mm long,<br />
1 mm thick <strong>HAT</strong><br />
(alternative)<br />
M-12 mm M M<br />
M-12 mm<br />
M-28 mm<br />
28 mm<br />
M-28 mm<br />
28 mm<br />
M-28 mm<br />
28 mm<br />
M-28 mm<br />
M M M<br />
1148 mm and<br />
2700 mm long,<br />
1 mm thick <strong>HAT</strong><br />
M-28 mm<br />
M-28 mm<br />
M-28 mm<br />
M-28 mm<br />
28 mm<br />
28 mm<br />
28 mm<br />
50 mm 50 mm 50 mm 2700 x 50 1200 mm<br />
50 mm<br />
Wall<br />
Rear view of installation<br />
seen from 'inside' the wall.<br />
2700 x 1200<br />
1200 x 1200<br />
2700 x 1200
VertiQ ® – <strong>System</strong> <strong>HAT</strong><br />
5. Perimeter trim<br />
Module (M)<br />
5.1 Mark out all the axes for perimeter trims and intermediate profiles.<br />
5.2 Top and side perimeter trims, 25 mm wide edge<br />
to the wall.<br />
30 mm<br />
30 mm<br />
30 mm<br />
5.3 Bottom perimeter trim resting on the floor or<br />
other solid base support material.<br />
Important<br />
M (using <strong>HAT</strong> top trim)<br />
M-12 (using J channel top trim)<br />
M (using <strong>HAT</strong> bottom trim)<br />
M-12 (using J channel bottom trim)<br />
• Use mounting screws/methods appropriate<br />
for the wall material.<br />
• Use a sharp-bladed saw to carefully achieve<br />
neat corner joints.<br />
• Placing an internal support, e.g. 40 mm<br />
thick wood block, inside the perimeter trim<br />
will reduce bending / damage when cutting.<br />
For off-floor installations, consideration should<br />
be given to using a scuff-resistant skirting or<br />
base support between the floor and bottom<br />
perimeter trim. This will reduce the likelihood<br />
of damage from shoes, luggage, vacuum<br />
cleaners or other floor-level risks and help<br />
avoid ball or human contact with any lowlying<br />
perimeter trim corners.<br />
13
14<br />
VertiQ ® – <strong>System</strong> <strong>HAT</strong><br />
6. Wall panels and horizontal intermediate profiles<br />
6.1 Start installing VertiQ wall panels<br />
working inward from the outside<br />
/ perimeter panels, both left and<br />
right, bottom panels first. Ensure<br />
that all outside / perimeter panel<br />
edges are securely under their<br />
perimeter trims.<br />
6.2 For multiple-height installations, place the next<br />
panel above and cover the horizontal joint(s)<br />
between panels with a 40 mm <strong>HAT</strong> profile the<br />
exact length of M-52 mm (see diagram on<br />
page 15), affixed at panel centre (figure 6.4).<br />
Ensure that the panel edges are covered by<br />
perimeter trims (J or <strong>HAT</strong>) and intermediate<br />
<strong>HAT</strong> profiles.<br />
6.4 Install all the remaining panels and horizontal <strong>HAT</strong> profiles, working toward the middle.<br />
6.3 All outside / perimeter panels installed with horizontal <strong>HAT</strong> profiles.<br />
52 mm<br />
Cover all the horizontal joints with <strong>HAT</strong> profiles<br />
centred on the panel width leaving a 52 mm gap<br />
between them for the vertical <strong>HAT</strong> profile.
VertiQ ® – <strong>System</strong> <strong>HAT</strong><br />
7. Vertical intermediate profiles<br />
M = Module<br />
50 mm<br />
vertical <strong>HAT</strong><br />
7.1 All VertiQ panels and <strong>HAT</strong> profiles installed.<br />
Wall<br />
M-28 mm<br />
VertiQ panel<br />
M<br />
M-52 mm<br />
horizontal <strong>HAT</strong><br />
50 mm<br />
vertical <strong>HAT</strong><br />
The vertical <strong>HAT</strong> profile edges should meet cleanly<br />
against the horizontal <strong>HAT</strong> profile edges, not<br />
overlap them.<br />
15
ACTIVATE YOUR CEILING<br />
<strong>Rockfon</strong>® develops intelligent ceiling and wall solutions which actively address<br />
a number of important issues in modern buildings and renovation projects.<br />
<strong>Rockfon</strong> products are known for their design, aesthetics and ease of<br />
installation, coupled with the key performance features of superior<br />
fire resistance and acoustics.<br />
This ensures that our acoustic solutions are among the highest performing,<br />
most cost effective and time efficient in today’s interiors market.<br />
This comprehensive portfolio from <strong>Rockfon</strong> enables our customers to<br />
actively add value to the construction process, by ultimately creating superior<br />
interior environments.<br />
That is why we say “ACTIVATE YOUR CEILING”.<br />
<strong>Rockfon</strong><br />
A trading division of Rockwool Limited<br />
26-28 Hammersmith Grove<br />
London<br />
W6 7HA<br />
Tel: 020 8222 7457<br />
Fax: 020 8222 7458<br />
www.rockfon.co.uk<br />
All colour codes mentioned are based on the NCS - Natural Colour<br />
<strong>System</strong> ®© property of and used on licence from NCS Colour AB,<br />
Stockholm 2010.<br />
Subject to alterations in range and product technology without prior<br />
notice. <strong>Rockfon</strong> accepts no responsibility for printing errors.<br />
01.2012