Lake Shore Cryotronics probe stations catalogue

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Probe <strong>stations</strong><br />

Probe <strong>stations</strong><br />

Options for every application<br />

Field installable options<br />

These options can be ordered at any time and either configured with a <strong>probe</strong> station or installed in the field.<br />

Installed options<br />

Unless otherwise specified, these options must be configured at the time of <strong>probe</strong> station purchase.<br />

Temperature<br />

Vacuum<br />

Temperature<br />

VLT<br />

Very low temperature<br />

CPX<br />

Extends the minimum sample temperature of the CPX <strong>probe</strong><br />

station to 1.6 K base temperature by lowering the pressure<br />

inside the sample stage heat exchanger. Upgrades the<br />

existing silicon diode sample stage sensor to a Cernox ®<br />

sensor. Limits high end temperature of <strong>probe</strong> station to<br />

400 K. The PS-VLT-CPX includes a SH-1.00-G grounded<br />

sample holder, 4 K shield, rotary vane pump, manual valve<br />

control, and connection adapters. The modified sample<br />

stage is optimized for cooling 25 mm (1 in) samples.<br />

Additional sample holders for the VLT operation are sold<br />

separately. 3-phase 208 V 50/60 Hz operation. 50 Hz<br />

operation may increase base temperature.<br />

Vibration<br />

Pneumatic vibration isolation system<br />

CPX, CPX-VF, TTPX<br />

For vibration sensitive applications, the PS-PVIS (PS-TTVIS<br />

for the TTPX) configuration is recommended when probing<br />

extremely fine detail, when making measurements that are<br />

very sensitive to mechanical noise, or when there are likely<br />

to be outside vibration sources near the <strong>probe</strong> station. The<br />

option adds active pneumatic vibration isolation to the<br />

integrated stand and requires a regulated source of 40 psi<br />

compressed air or nitrogen.<br />

Function<br />

Heavy duty welded steel stand<br />

TTPX<br />

The PS-STAND-TTPX provides a stable platform for the<br />

TTPX.<br />

12:1 microscope upgrade<br />

TTPX, CPX, CPX-VF, CRX-4K, CRX-6.5K, CRX-VF, CRX-EM-HF<br />

Upgrades the <strong>probe</strong> station vision system to 12:1<br />

microscope for higher magnification. See the Vision System<br />

page for additional details.<br />

360° sample stage rotation<br />

EMPX-H2, CRX-EM-HF<br />

Provides 360° rotation of the sample stage.<br />

The PS-360-EMPX is recommended for<br />

measurements that require changing the<br />

sample alignment relative to the magnetic<br />

field. The rotation stage is also useful for aligning GSG<br />

<strong>probe</strong> tips for microwave measurements. Limits the overall<br />

temperature range to 8 K to 400 K. The thermal gradient<br />

between the top of the rotation stage and the sample stage<br />

temperature sensor is