Diffusion Testing<br />
with <strong>RTD</strong> MultiGas Technology<br />
Now Available<br />
<strong>RTD</strong> <br />
MultiGas Technology<br />
MEDGRAPHICS ® systems offer maximum fl exibility to confi gure pulmonary function testing<br />
to meet your diagnostic and clinical practice needs:<br />
Choose your diffusion technology with confi dence --<br />
• Real Time Diffusion, <strong>RTD</strong> MultiGas Technology, delivering rapid measurement,<br />
clinically signifi cant graphic data and immediate results<br />
• Reference Standard Gas Chromatography providing exceptional consistency and<br />
time honored precision<br />
Both technologies meet or exceed current ATS/ERS guidelines and can be verifi ed by<br />
the Hans Rudolph DLco Simulator, recognized as the Laboratory Quality Control for<br />
single-breath diffusion systems.<br />
Availability:<br />
• <strong>Ultima</strong> Series (PF)<br />
• Platinum Elite Series (DL & DX)<br />
<strong>RTD</strong> MultiGas Technology provides graphic visualization of exhaled dead space clearance,<br />
delivering accurate - not estimated - discard and sample volume adjustments, independent of<br />
exhaled fl ow rate, eliminating the need of repeating tests.<br />
Together with real time CO-CO2 cross sensitivity compensation, MEDGRAPHICS systems<br />
deliver the latest developments in Real-Time Diffusion Technology.<br />
Methodology:<br />
Analysis Time:<br />
Range:<br />
Accuracy:<br />
Linearity:<br />
Resolution:<br />
Supplies:<br />
<strong>RTD</strong> MultiGas Technology<br />
Infrared<br />
<strong>Medical</strong> <strong>Graphics</strong> <strong>Corporation</strong><br />
350 Oak Grove Parkway<br />
St. Paul, MN 55127-8599<br />
Toll Free: 800.655.1133<br />
International: +1.651.484.4874<br />
Fax: +1.651.484.8941<br />
www.medgraphics.com<br />
info@medgraphics.com<br />
Part #060113-001 Rev B<br />
Single S l screen volume l and d gas concentration tracings.<br />
Easily identify baseline stability, MultiGas alignment<br />
and visual quality control.<br />
Zoom-View Z Vi pprovides id hi high h ddefi finition i i di discard d and d<br />
sample volume inspection and assures accurate<br />
alignment of gas tracing with volume signal,<br />
independent of exhaled fl ow rate.<br />
All specifi cations subject to change<br />
without notice. Products may vary from<br />
those illustrated. Please contact your<br />
<strong>Medical</strong> <strong>Graphics</strong> representative for latest<br />
information, pricing and product availability.<br />
© 2012 <strong>Medical</strong> <strong>Graphics</strong> <strong>Corporation</strong>.<br />
MEDGRAPHICS is a registered trademark<br />
and <strong>Ultima</strong> and <strong>RTD</strong> are trademarks of<br />
<strong>Medical</strong> <strong>Graphics</strong> <strong>Corporation</strong>.<br />
MEDGRAPHICS Europe<br />
Via Simone d’Orsenigo n.21<br />
20135 Milano, Italy<br />
Phone: +39 346-857-5928<br />
Fax: +39 025-412-0233<br />
<strong>RTD</strong> MultiGas Technology<br />
Benefi ts<br />
• Visual inspection of CO (diffusion) and<br />
CH4 (dilution) traces assures true<br />
alveolar sample collection<br />
• Continuous measurement and display<br />
of CO and CH4 tracing provide subject<br />
and system Quality Assurance<br />
• System calibration using the <strong>RTD</strong><br />
sample line eliminates discrepancies<br />
between the internal “plumbing” and<br />
subject sample line<br />
• Real time alignment of inhaled and<br />
exhaled gas concentrations with fl ow<br />
and volume, eliminate the need for<br />
post-test, back extrapolated software<br />
corrections<br />
• Ability to change the discard and<br />
sample volume allows accurate<br />
measurement of subjects with reduced<br />
vital capacity<br />
• Single breath lung volume<br />
determination<br />
For more information, visit<br />
www.medgraphics.com