58mca 6
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
UNIT
SIZE
VOLTS—
HERTZ—
PHASE
OPERATING
VOLTAGE RANGE
Max* Min*
Table 4—Electrical Data
MAX
UNIT
AMPS
UNIT
AMPACITY†
MIN
WIRE
SIZE
MAX WIRE
LENGTH
(FT)‡
MAX FUSE
OR CKT BKR
AMPS**
040-08 115—60—1 127 104 6.1 8.4 14 44 15
040-12 115—60—1 127 104 7.3 10.0 14 37 15
060-08 115—60—1 127 104 6.1 8.4 14 44 15
060-12 115—60—1 127 104 7.1 9.8 14 38 15
060-16 115—60—1 127 104 9.5 12.8 14 29 15
080-12 115—60—1 127 104 7.6 10.4 14 36 15
080-16 115—60—1 127 104 10.0 13.4 14 28 15
080-20 115—60—1 127 104 14.1 18.4 12 31 20
100-16 115—60—1 127 104 10.2 13.5 14 27 15
100-20 115—60—1 127 104 14.8 19.3 12 30 20
120-20 115—60—1 127 104 14.6 19.1 12 30 20
140-20 115—60—1 127 104 14.3 18.8 12 30 20
* Permissible limits of voltage range at which unit will operate satisfactorily.
† Unit ampacity = 125 percent of largest operating component’s full load amps plus 100 percent of all other potential operating components’ (EAC, humidifier, etc.) full
load amps.
‡ Length shown is as measured 1 way along wire path between unit and service panel for maximum 2 percent voltage drop.
** Time-delay type is recommended.
BLOWER OFF-DELAY
TWINNING AND/OR
COMPONENT TEST
TERMINAL
J2 JUMPER
BLOWER OFF-DELAY
J2
90 150
120 180
HUMIDIFIER TERMINAL
(24-VAC 0.5 AMP MAX.)
24-V THERMOSTAT
TERMINALS
G Com W Y R
24V
TEST/TWIN
HUM
PLT
TRANSFORMER 24-VAC
CONNECTIONS
3-AMP FUSE
LED OPERATION &
DIAGNOSTIC LIGHT
115-VAC(L2)NEUTRAL
CONNECTIONS
NUETRAL BLW
STATUS CODE LED
FUSE 3-AMP
SEC-2 SEC-1
EAC-2
0.5 AMP@24VAC
L2
PLT 1
PL1-LOW VOLTAGE MAIN
HARNESS CONNECTOR
COOL
HEAT
COOL HEAT
1-AMP@
SPARE-1 SPARE-2
EAC-1 115VAC
PR-1
L1
PL2 1
SPARE-1
SPARE-2
BLOWER SPEED
SELECTION TERMINALS
115 VAC (L1) LINE
VOLTAGE CONNECTION
EAC-1 TERMINAL
(115-VAC 1.0 AMP MAX.)
PL2-HOT SURFACE
IGNITER & INDUCER
MOTOR CONNECTOR
Fig. 31—Control Board
A02100
22
Downloaded from www.Manualslib.com manuals search engine