<strong>Relay</strong> <strong>couplers</strong> - <strong>PLUGSERIES</strong><br />
2 change-over contacts<br />
AC/DC coil<br />
Modular system comprising<br />
• relay socket for rail mounting<br />
• LED indicator unit / RC combination<br />
• Retaining clip<br />
• plug-in relay<br />
cross-section of coil connections<br />
and relay changeover contacts by means of<br />
plug-in cross-connection ZQV 2.5N<br />
20<br />
DC version<br />
A 1<br />
A2<br />
AC version<br />
A 1<br />
A2<br />
Applications<br />
switching voltage [V-]<br />
Switching cycles<br />
DC limit curve<br />
. . .<br />
1 contact<br />
Electrical endurance<br />
12<br />
12<br />
14<br />
11<br />
14<br />
11<br />
22<br />
22<br />
21<br />
21<br />
2-pole<br />
Resistive load<br />
2 contacts in series<br />
DC coil<br />
AC coil<br />
250 V AC<br />
Resistive load<br />
Switching current [A]<br />
24<br />
24<br />
Output<br />
max. switching voltage AC/Continuous current 250 V/10 A<br />
min. switching power 10 V / 100 mA<br />
Response time / Drop-out time 9ms/45ms<br />
Contact base material AgNi 90/10<br />
Mechanical endurance 5x106 switching cycles<br />
max. switching frequency at rated load<br />
Rated data<br />
0.1 Hz<br />
Status indicator/Free wheel diode green LED/Yes<br />
Reverse pol. prot available<br />
Operating temperature -40 °C…+50 °C<br />
Storage temperature -40 °C…+50 °C<br />
Humidity 40°C/93% RH, no condensation<br />
Approvals<br />
Insulation coordination (EN 50178)<br />
CE;cURus;<br />
Standards EN 50178<br />
Rated voltage 250 V<br />
Impulse withstand voltage 6 kV<br />
Creepage and clearance path input - output > 8 mm<br />
Overvoltage category III<br />
Pollution severity 2<br />
Protective separation to VDE 0106 part 101 yes<br />
Dimensions Screw connection Tension clamp connection<br />
Clamping range (rating- / min. / max.) mm2 2.5 / 0.5 / 2.5 2.5 / 0.5 / 2.5<br />
Length x width x height mm 92 / 15.3 / 95 92 / 15.3 / 87<br />
Note Cross-connectors and markers - see <strong>PLUGSERIES</strong> accessories<br />
Coil voltage (U/Un)<br />
Coil voltage (U/Un)<br />
DC operating voltage range<br />
.<br />
.<br />
.<br />
.<br />
.<br />
.<br />
.<br />
Un Nom. voltage<br />
AC operating voltage range<br />
.<br />
.<br />
.<br />
.<br />
.<br />
.<br />
. Un Nom. voltage<br />
.<br />
.<br />
Ambient temperature [°C]<br />
Ambient temperature [°C]