25.04.2024 Views

Excess Flow Valves FITOK EN

Excess Flow Valves FITOK EN Available @ https://fitok.ch and https://schalcher-engineering.ch FITOK Group has been an industry-leading developer and manufacturer of superior quality instrumentation valves and fittings. We have the capability to manufacture and supply 5 different product categories, including: ■ General Instrumentation Valves and Fittings ■ Medium & High Pressure Valves and Fittings ■ High Purity & Ultra High Purity Products ■ Sampling Systems ■ Tubing Our mission is to provide the best quality products and the most professional services to our customers. The performance of our products is guaranteed during the whole manufacturing cycle from our employment of customized materials which should be controlled more strictly than just according to ASTM requirements to our implementation of production and testing exceeding the industry standards. Since our inception, FITOK has been applying sound quality control standards in all activities. FITOK is an ISO 9001 :2015 certified company and our products have been certified by different industry authorities and third-party inspection institutions in different countries to have obtained a variety of certificates, among which there are the TA-Luft, ABS, ASTM F1387, ISO15848, TPED, E-Mark, CRN, DVGW, PED, API and DOT certificates. Benefiting from our global facilities, we are able to optimize the most cost-effective resources worldwide. Paired with flexible manufacturing systems, we deliver a wide range of the best quality products within a competitive lead time and the most professional services to our customers in an array of applications and industries.

Excess Flow Valves FITOK EN
Available @ https://fitok.ch and https://schalcher-engineering.ch

FITOK Group has been an industry-leading developer and manufacturer of superior quality instrumentation valves and fittings. We have the capability to manufacture and supply 5 different product categories, including:

■ General Instrumentation Valves and Fittings
■ Medium & High Pressure Valves and Fittings
■ High Purity & Ultra High Purity Products
■ Sampling Systems
■ Tubing

Our mission is to provide the best quality products and the most professional services to our customers. The performance of our products is guaranteed during the whole manufacturing cycle from our employment of customized materials which should be controlled more strictly than just according to ASTM requirements to our implementation of production and testing exceeding the industry standards.

Since our inception, FITOK has been applying sound quality control standards in all activities. FITOK is an ISO 9001 :2015 certified company and our products have been certified by different industry authorities and third-party inspection institutions in different countries to have obtained a variety of certificates, among which there are the TA-Luft, ABS, ASTM F1387, ISO15848, TPED, E-Mark, CRN, DVGW, PED, API and DOT certificates.

Benefiting from our global facilities, we are able to optimize the most cost-effective resources worldwide. Paired with flexible manufacturing systems, we deliver a wide range of the best quality products within a competitive lead time and the most professional services to our customers in an array of applications and industries.

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Excess</strong> <strong>Flow</strong> <strong>Valves</strong><br />

EV Series<br />

Schalcher Engineering GmbH<br />

Städeliweg 7 | 9220 Bischofszell<br />

Tel.: +41 71 950 12 77 | E-Mail: info@schalcher-engineering.ch<br />

www.schalcher-engineering.ch | www.fitok.ch<br />

www.fitok.com


1 <strong>Excess</strong> <strong>Flow</strong> <strong>Valves</strong><br />

<strong>Excess</strong> <strong>Flow</strong> <strong>Valves</strong><br />

EV Series<br />

Introduction<br />

If downstream line ruptures, the excess flow valve can stop uncontrolled release of system media. When the system is<br />

functioning normally, the working element remains in the open position. If the excess flow occurs downstream, the working<br />

element quickly moves to the tripped position to stop bleeding. When system pressure reaches balance through the bleed vent,<br />

the spring resets the working element to the open position automatically. The flow which goes through the bleed vent should<br />

be lower than one percent of the flow rate in the trip range.<br />

Features<br />

◎ Compact design for convenient installation<br />

◎ Working pressure up to: 6000 psig (414 bar)<br />

◎ Working temperature: -10F ° to 400° F (-23° C to 204°<br />

C)<br />

◎ Variety of end connections<br />

◎ Stainless steel construction<br />

◎ Leak-tight performance testing for every valve with<br />

nitrogen at the maximum working pressure<br />

End Connection:<br />

tube fitting, thread or<br />

face sealed<br />

◎ Easy installation<br />

◎ Improved system reliability<br />

Spring Drive to Brake<br />

◎ Easy operation<br />

◎ Enabled to work in any<br />

direction and improve<br />

the safety of system<br />

All Metal Seat<br />

◎ Enhanced durability<br />

◎ No maintenance needed<br />

Working Element<br />

◎ Improved capability and reliability<br />

◎ High flow capability<br />

◎ Nuisance tripping eliminated<br />

Bleed Vent<br />

◎ Eliminate complicated<br />

by-pass mechanism<br />

◎ Spring resets the element<br />

automatically<br />

Temperature Ranges for Different Seal Materials<br />

O-ring Material Temperature Ranges o F ( o<br />

C)<br />

Buna N<br />

EPDM<br />

Fluorocarbon FKM<br />

FFKM<br />

Neoprene<br />

-40 to 250 (-40 to 121)<br />

-50 to 300 (-45 to 148)<br />

-10 to 400 (-23 to 204)<br />

-10 to 527 (-23 to 275)<br />

-40 to 250 (-40 to 121)


<strong>Flow</strong> Data at 70 o o<br />

F (20 C)<br />

Air <strong>Flow</strong><br />

4 Series 6 Series<br />

lnlet Pressure (psig)<br />

4000<br />

3000<br />

2000<br />

1000<br />

800<br />

600<br />

Air <strong>Flow</strong> (std L/min)<br />

2000 3000 4000 6000 800010000<br />

400<br />

300<br />

Open<br />

Trip<br />

Range<br />

400<br />

300<br />

Tripped 20<br />

200<br />

10<br />

100<br />

8<br />

40 60 80 100 200 300 400<br />

Air <strong>Flow</strong> (std ft 3 /min)<br />

200<br />

100<br />

80<br />

60<br />

40<br />

30<br />

lnlet Pressure (bar)<br />

lnlet Pressure (psig)<br />

4000<br />

3000<br />

2000<br />

1000<br />

800<br />

600<br />

Air <strong>Flow</strong> (std L/min)<br />

<strong>Excess</strong> <strong>Flow</strong> <strong>Valves</strong> 2<br />

3000 4000 6000 800010000 20000<br />

Open<br />

Trip<br />

Range<br />

400<br />

300<br />

200<br />

100<br />

80<br />

60<br />

40<br />

30<br />

400<br />

300<br />

200<br />

Tripped<br />

20<br />

10<br />

100<br />

8<br />

80 100 200 300 400 600 800<br />

Air <strong>Flow</strong> (std ft 3 /min)<br />

lnlet Pressure (bar)<br />

8 Series<br />

lnlet Pressure (psig)<br />

4000<br />

3000<br />

2000<br />

1000<br />

800<br />

600<br />

3000 4000 6000 8000 10000 20000 30000<br />

Open<br />

Air <strong>Flow</strong> (std L/min)<br />

Trip<br />

Range<br />

400<br />

300<br />

200<br />

100<br />

80<br />

60<br />

40<br />

30<br />

400<br />

300<br />

200<br />

Tripped<br />

20<br />

10<br />

100<br />

8<br />

100 200 300 400 600 800 10001200<br />

Air <strong>Flow</strong> (std ft 3 /min)<br />

lnlet Pressure (bar)<br />

Water <strong>Flow</strong><br />

Series Cv<br />

4 0.5<br />

6 1.1<br />

8 1.1<br />

Trip Range<br />

gal/m in /min (L/min)<br />

3.9 to 5.8 (14.7 to 21.9)<br />

8.2 to 10.0 (31.0 to 37.8)<br />

11.2 to 14.9 (42.3 to 56.3)<br />

7<br />

Standard Materials of Construction<br />

6<br />

Component<br />

Material Grade/ASTM Specification<br />

5<br />

1<br />

Inlet Body<br />

316 SS/A479<br />

4<br />

2<br />

Mark Ring<br />

6061 Al/B491<br />

3<br />

Working Element<br />

316 SS/A479<br />

3<br />

4 Spring<br />

302 SS/A313<br />

2<br />

5<br />

6<br />

O-ring<br />

Seal Ring<br />

Fluorocarbon FKM<br />

PTFE/D1710<br />

1<br />

7<br />

Outlet Body<br />

316 SS/A479


3 <strong>Excess</strong> <strong>Flow</strong> <strong>Valves</strong><br />

Dimensions<br />

B<br />

C<br />

A<br />

Basic<br />

Ordering<br />

Number<br />

Connections Type and Size<br />

Inlet<br />

Outlet<br />

Pressure Rating<br />

at 37° C(100°<br />

F)<br />

psig(bar)<br />

Series<br />

A<br />

Dimension, in. (mm)<br />

B<br />

C<br />

EV □□-FL4-4-<br />

1/4" <strong>FITOK</strong><br />

1/4" <strong>FITOK</strong><br />

4<br />

2.43<br />

(61.7)<br />

11/16 11/16<br />

(17.46) (17.46)<br />

EV □□-FL6-6-<br />

EV □□-FL8-8-<br />

3/8" <strong>FITOK</strong><br />

1/2" <strong>FITOK</strong><br />

3/8" <strong>FITOK</strong><br />

1/2" <strong>FITOK</strong><br />

6000(414)<br />

6<br />

8<br />

2.75<br />

(69.9)<br />

2.97<br />

(75.4)<br />

1<br />

(25.4)<br />

1<br />

(25.4)<br />

EV □□-ML6-4-<br />

6 mm <strong>FITOK</strong><br />

6 mm <strong>FITOK</strong><br />

4<br />

2.43<br />

(61.7)<br />

11/16 11/16<br />

(17.46) (17.46)<br />

EV □□-ML8-6-<br />

EV □□-ML10-6-<br />

8 mm <strong>FITOK</strong><br />

10 mm <strong>FITOK</strong><br />

8 mm <strong>FITOK</strong><br />

10 mm <strong>FITOK</strong><br />

6000(414)<br />

6<br />

2.70<br />

(68.6)<br />

2.80<br />

(71.1)<br />

1<br />

1<br />

(25.4) (25.4)<br />

EV □□-ML12-8-<br />

12 mm <strong>FITOK</strong><br />

12 mm <strong>FITOK</strong><br />

8<br />

2.96<br />

(75.2)<br />

EV □□-FNS2-4-<br />

EV □□-FNS4-4-<br />

EV □□-FNS6-6-<br />

1/8 Female NPT<br />

1/4 Female NPT<br />

3/8 Female NPT<br />

1/8 Female NPT<br />

1/4 Female NPT<br />

3/8 Female NPT<br />

6000(414)<br />

5300(365)<br />

4<br />

6<br />

1.87<br />

(47.5)<br />

2.12<br />

(53.8)<br />

2.55<br />

(64.8)<br />

11/16 11/16<br />

(17.46) (17.46)<br />

1 1<br />

(25.4) (25.4)<br />

EV □□-FNS8-8-<br />

EV □□-NS2-4-<br />

EV □□-NS4-4-<br />

EV □□-NS6-6-<br />

EV □□-NS8-8-<br />

1/2 Female NPT<br />

1/8 Male NPT<br />

1/4 Male NPT<br />

3/8 Male NPT<br />

1/2 Female NPT<br />

1/8 Male NPT<br />

1/4 Male NPT<br />

3/8 Male NPT<br />

1/2 Male NPT 1/2 Male NPT<br />

4900(337)<br />

6000(414)<br />

5300(365)<br />

8<br />

4<br />

6<br />

8<br />

3.03<br />

(77.0)<br />

1.79<br />

(45.5)<br />

2.17<br />

(55.1)<br />

2.36<br />

(59.9)<br />

2.73<br />

(69.3)<br />

1 1/16 1 1/16<br />

(26.99) (26.99)<br />

11/16 11/16<br />

(17.46) (17.46)<br />

1 1<br />

(25.4) (25.4)<br />

EV □□-NS4-FL4-4-<br />

1/4 Male NPT<br />

1/4 " <strong>FITOK</strong><br />

4<br />

2.30<br />

(58.4)<br />

11/16 11/16<br />

(17.46) (17.46)<br />

EV □□-NS6-FL6-6-<br />

EV □□-NS8-FL8-8-<br />

3/8 Male NPT<br />

1/2 Male NPT<br />

3/8" <strong>FITOK</strong><br />

1/2"<br />

<strong>FITOK</strong><br />

6000(414)<br />

6<br />

8<br />

2.56<br />

(65.0)<br />

2.85<br />

(72.4)<br />

1 1<br />

(25.4) (25.4)<br />

EV □□-NS4-FNS4-4-<br />

EV □□-NS6-FNS6-6-<br />

1/4 Male NPT<br />

3/8 Male NPT<br />

1/4 Female NPT<br />

3/8 Female NPT<br />

6000(414)<br />

5300(365)<br />

4<br />

6<br />

2.13<br />

(54.1)<br />

2.46<br />

(62.5)<br />

11/16 11/16<br />

(17.46) (17.46)<br />

1<br />

(25.4)<br />

1<br />

(25.4)<br />

EV □□-NS8-FNS8-8-<br />

1/2 Male NPT<br />

1/2 Female NPT<br />

4900(337)<br />

8<br />

3.03<br />

(77.0)<br />

1 1/16 1 1/16<br />

(26.99) (26.99)<br />

1. <strong>FITOK</strong> means <strong>FITOK</strong> double ferrule tube fittings.<br />

2. Sizes and types listed are standard. Other sizes and types are available upon request.<br />

3. Dimensions are shown with <strong>FITOK</strong> nuts finger-tightened. All dimensions are for reference only and are subject to change.<br />

For dimensions not shown above, please contact the authorized representative or <strong>FITOK</strong> Group.


<strong>Excess</strong> <strong>Flow</strong> <strong>Valves</strong> 4<br />

Ordering Number Description<br />

EVSS - FL6 - ML8 - 6Z - SF2<br />

Series Body Material Inlet Type<br />

Outlet<br />

Inlet Size<br />

Outlet<br />

Type Size<br />

Series<br />

Seal<br />

Material<br />

Special<br />

Application<br />

Cleaning and<br />

Packaging<br />

EV<br />

SS<br />

S4<br />

S1<br />

6L<br />

4L<br />

316 SS<br />

304 SS<br />

321 SS<br />

316L SS<br />

304L SS<br />

FNS Female NPT<br />

NS Male NPT<br />

FRT Female BSPT<br />

RT Male BSPT<br />

Female Metric<br />

FMS Thread<br />

(for RP-M)<br />

Male Metric<br />

MS Thread<br />

(for RG-M)<br />

FRP<br />

Female BSPP<br />

(for RP)<br />

BP<br />

Male BSPP<br />

(for RG)<br />

Fractional Tube<br />

FL Fitting<br />

ML<br />

Metric Tube<br />

Fitting<br />

2 1/8"<br />

4 1/4"<br />

6 3/8 " or 6 mm<br />

8 1/2" or 8 mm<br />

10 10 mm<br />

12 3/4"<br />

or 12 mm<br />

Same as Inlet<br />

Specified in the<br />

same way as<br />

the inlet type<br />

and size<br />

4<br />

6<br />

8<br />

B<br />

N<br />

E<br />

Z<br />

Fluorocarbon<br />

FKM<br />

Buna N<br />

Neoprene<br />

EPDM<br />

FFKM<br />

NO<br />

S<br />

NACE<br />

MR0175<br />

FC-01<br />

F2 FC-02<br />

Note: "Ordering Number Description" is a reference to understand the combination<br />

rules of <strong>FITOK</strong> product part number. Not all combinations are available.<br />

1. Standard thread pitch for metric threads are as follows:<br />

M10 and below: 1 mm<br />

M12 to M24: 1.5 mm<br />

M27 and above: 2 mm<br />

Standard thread pitch should be ignored in the ordering number, others<br />

should be specified.<br />

2. Cleaning and Packaging:<br />

FC-01: Standard cleaning and packaging for general industrial procedures.<br />

FC-02: Special cleaning and packaging for wetted system components to<br />

ensure compliance with product cleanliness requirement of ASTM<br />

G93 Level C.


info@fitok.com<br />

www.fitok.com<br />

FK-IC-GV-08-<strong>EN</strong>-221014

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!