<strong>BR</strong><strong>DOL</strong> 09-18<br />
<strong>BR</strong><strong>DOL</strong> 25-32<br />
<strong>BR</strong><strong>DOL</strong> 40-95<br />
<strong>BR</strong> <strong>DOL</strong> <strong>Starter</strong><br />
1. APPLICATION<br />
<strong>BR</strong><strong>DOL</strong> direct on line (<strong>DOL</strong>) starter start the motor with full voltage.<br />
<strong>BR</strong><strong>DOL</strong> motor starter contain protection devices which can prevent the motor from overload or phase failure.<br />
The starter is offen used to start 3-phase squirrel motor such as water pumps, compressors fans and conveyor<br />
belts.<br />
The product comform to Standard IEC60947.<br />
2. MODEL AND MEANING<br />
<strong>BR</strong> <strong>DOL</strong><br />
o~íÉÇ=çéÉê~íáçå~ä=ÅìêêÉåí ^`JP=PUMs<br />
aÉëáÖå=ëÉèìÉåÅÉ=kç<br />
Company<br />
3. NORMAL WORKING CONDITIONS<br />
PKN=^ãÄáÉåí=~áê=íÉãéÉê~íìêÉW=JR HQM I=íÜÉ=~îÉê~ÖÉ=î~äìÉ=ëÜçìäÇ=åçí=ÉñÅÉÉÇ=HPR =ïáíÜáå=OQ=ÜçìêëK<br />
3.2 Altitude: Less than 2000M.<br />
PKP=^íãçëéÜÉêáÅ=ÅçåÇáíáçåëW=tÜÉå=íÜÉ=íÉãéÉê~íìêÉ=~í=QMI=íÜÉ=êÉä~íáîÉ=ÜìãáÇáíó=çÑ=~íçãëéÜÉêÉ=ëÜçìäÇ=ÄÉ<br />
=====~í=íÜÉ=ãçëí=RMBK=tÜÉå=~í=êÉä~íáîÉäó=äçï=íÉãéÉê~íìêÉëI=áí=ÅçìäÇ=Ü~îÉ=ÜáÖÜÉê=êÉä~íáîÉ=ÜìãáÇáíóK=jçåíÜäó<br />
=====ã~ñáãìã=êÉä~íáîÉ=ÜìãáÇáíó=ÅçìäÇ=ÄÉ=åçí=ãçêÉ=íÜ~å=VMBK=péÉÅá~ä=ãÉ~ëìêÉë=ëÜçìäÇ=ÄÉ=í~âÉå=ÇìÉ=íç<br />
=====çÅÅìêêÉåÅÉ=çÑ=ÇÉïëK<br />
PKQ=`ä~ëë=çÑ=éçääìíáçåW=`ä~ëë=P<br />
PKR=fåëí~ää~íáçå=Å~íÉÖçêóW==III<br />
PKS=fåëí~ää~íáçå=ÅçåÇáíáçåëW=aÉÖêÉÉ=çÑ=áåÅäáå~íáçå=ÄÉíïÉÉå=ÑáííáåÖ=ëìêÑ~ÅÉ=~åÇ=îÉêíáÅ~ä=ëìêÑ~ÅÉ=ëÜçìäÇ=åçí<br />
=====ÉñÅÉÉÇ=5 degrees.<br />
3.7 Viberation: Product should be mounted on bases without suffering from viberation.<br />
4. TYPE OF CONSTRUCTION<br />
The casing the product is IP65. Inside the thermal overload relay connect with the contactor which<br />
provide the control and protection of motor. Two buttons on the casing, green for "Start" and red<br />
for "Stop".<br />
K<br />
5. MAIN TECHNICAL PARAMETER<br />
o~íÉÇ=çéÉê~íáçå~ä `çåîÉåJ mçïÉê=çÑ=Åçåíêçää~ÄäÉ=PJéÜ~ëÉ ^îÉê~ÖÉ=éçïÉê=ÅçåJ<br />
íáçå~ä<br />
ÅìêêÉåíE^F=PUMs<br />
ëèìáêêÉäJÅ~ÖÉ=ãçíçê=EâtF^`JP<br />
ÜÉ~íáåÖ<br />
ëìãéíáçå=s^=EOM<br />
jçÇÉä ^`P ^`Q ÅìêêÉåíE^F OOMs PUMs SSMs<br />
ç m~ê~ãÉíÉê<br />
`F=RMeò<br />
máÅâJìé eçäÇáåÖ<br />
fíÉã<br />
<strong>BR</strong><strong>DOL</strong>-09<br />
<strong>BR</strong><strong>DOL</strong>-12<br />
<strong>BR</strong><strong>DOL</strong>-18<br />
<strong>BR</strong><strong>DOL</strong>-25<br />
<strong>BR</strong><strong>DOL</strong>-32<br />
<strong>BR</strong><strong>DOL</strong>-40<br />
<strong>BR</strong><strong>DOL</strong>-50<br />
<strong>BR</strong><strong>DOL</strong>-65<br />
<strong>BR</strong><strong>DOL</strong>-80<br />
<strong>BR</strong><strong>DOL</strong>-95<br />
MV<br />
NO<br />
NU<br />
OR<br />
PO<br />
QM<br />
RM<br />
SR<br />
UM<br />
VR<br />
PKR<br />
R<br />
TKT<br />
UKR<br />
NO<br />
NUKR<br />
OQ<br />
OU<br />
PT<br />
QQ<br />
OM<br />
OM<br />
PO<br />
QM<br />
RM<br />
SM<br />
UM<br />
UM<br />
NNM<br />
NNM<br />
OKO<br />
P<br />
Q<br />
RKR<br />
TKR<br />
NN<br />
NR<br />
NUKR<br />
OO<br />
OR<br />
Q<br />
RKR<br />
TKR<br />
NN<br />
NR<br />
NUKR<br />
OO<br />
PM<br />
PT<br />
QR<br />
RKR<br />
TKR<br />
NM<br />
NR<br />
NUKR<br />
PM<br />
PP<br />
PT<br />
QR<br />
RR<br />
TS<br />
TS<br />
TS<br />
NNM<br />
NNM<br />
OPM<br />
OPM<br />
OPM<br />
OPM<br />
OPM<br />
VKQ<br />
VKQ<br />
VKQ<br />
NN<br />
NN<br />
PO<br />
PO<br />
PO<br />
PO<br />
PO<br />
råáí<br />
ïÉáÖÜí<br />
EâÖF<br />
MKV<br />
MKV<br />
MKVO<br />
NKP<br />
NKPP<br />
PKSR<br />
PKSR<br />
PKSR<br />
PKU<br />
PKU
6. OVERALL AND MOUNTING DIMENSIONS<br />
<strong>BR</strong><strong>DOL</strong> 09-18<br />
<strong>BR</strong><strong>DOL</strong> 25-32<br />
<strong>BR</strong><strong>DOL</strong> 40-95<br />
7. WIRING SCHEME