31.12.2012 Views

Kaiser Filters

Kaiser Filters

Kaiser Filters

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

4030<br />

„digital timer“ Electronic<br />

Exposure Timer<br />

Time range: 0.1 - 99 seconds<br />

Display: 0.1 - 9.9 seconds in 10th sec.<br />

increments, and 10-99<br />

seconds in sec. increments<br />

Maximum switching capacity: 500 W<br />

Dimensions: approx. 100 x 75 x 152 mm<br />

(3.9 x 3 x 6 in.)<br />

Power cable: 2 m (6 ft 7 in.)<br />

4021/24<br />

ATU 160 / MT 60 Exposure Timer<br />

4029<br />

cpa 3 Color Analyzer<br />

Lab<br />

2-digit amber-colored display. Time settings<br />

with step-up/step-down keys. Time countdown<br />

to zero, then reset to starting time<br />

(can be repeated any number of times for<br />

exposure series). Interrupt and restart of<br />

remaining time, and interruption with direct<br />

reset to the set starting time are likewise<br />

possible.<br />

Focusing light switch. Matt black housing<br />

made of impact resistant plastic.<br />

Operation by way of four large pushbuttons<br />

that can be easily located in the dark.<br />

Powered by snychromotor for time<br />

intervals between 1 and 60 seconds. Time<br />

set with a knurled knob. Wide start key. The<br />

set time can be repeated any number of<br />

times for exposure series. Timing can be<br />

interrupted. Focusing light switch. Matt black<br />

housing made of impact-resistant plastic.<br />

Luminescent scale.<br />

Max. switching capacity: 500 W<br />

ATU 160 (4021) with red follow-pointer<br />

indicating how much time has elapsed.<br />

Dimensions: approx. 100 x 81 x 152 mm<br />

(3.9 x 3.2 x 6 in.)<br />

Power cable: 2 m (6 ft. 7 in.)<br />

4-channel color analyser for assessing exact<br />

filtration. Suitable for processing colour and<br />

colour reversal papers. Selective or average<br />

metering. Swivel measuring head with 5 mm<br />

(0.2 in.) measuring point and channel switch.<br />

Insensitive to darkroom safelight. Digital<br />

display of filtration values in densitometric<br />

densities of 0 to ±300. Mechanically adjustable<br />

memory for storage without power<br />

supply.<br />

Measuring range log. density: ±3.5.<br />

Complete with diffuser and screwdriver.<br />

Dimensions: (WxHxD): approx. 170 x 60 x<br />

155 mm (6.7 x 2.4 x 6.1 in.)<br />

Cord: 1.7 m (5 ft. 7 in.)<br />