Device Possible error possible cause<br />
Sahneboy<br />
The charger can’t be pierced; the<br />
piercing unit is not visible.<br />
Cream escapes from the nozzle.<br />
The position of the charger holder and<br />
the nozzle were interchanged after<br />
cleaning.<br />
The valve rod is missing.<br />
Valve rod was inserted the wrong way<br />
into the head.<br />
Valve seat in the head is damaged.<br />
Ingredients used (powdered sugar,<br />
cream stiffener, etc.) did not dissolve<br />
completely and prevent valve from<br />
sealing.<br />
The device was shaken too much, so<br />
that crumbly cream prevents proper<br />
sealing.<br />
<strong>Error</strong> solution<br />
Nr.:KAG.D003.2E<br />
Page 4 of 5<br />
Fix the nozzle onto the plastic thread<br />
and the charger holder onto the<br />
metal thread.<br />
Insert the valve rod properly -spring<br />
first- into the head.<br />
Insert the valve rod properly with<br />
the spring in front into the head.<br />
Send device to <strong>Kayser</strong>.<br />
Only use ingredients which dissolve<br />
completely. Stir up well before fixing<br />
the head.<br />
Empty the device, restart preparing<br />
the cream and shake less.