5.2.8 Auto test<br />

REV01 - Aug. 06<br />

Ideas with Passion<br />

On selection of this function, an automatic test is run on the machine functions, with results reported on the<br />

display. Before starting the test, all drawers and the tank must be inserted, all doors closed and the relative<br />

recipients must be filled with water and coffee.<br />

Test type Description Message if<br />

function OK<br />

Error message<br />

2.7.1 External ram<br />

test<br />

Check CPU ram successful ! failed !<br />

2.7.2 Flash test Check CPU flash memory successful ! failed !<br />

2.7.3 Eeprom test Check non volatile memory with machine settings successful ! failed !<br />

2.7.4 RTC test Check real time clock successful ! failed !<br />

2.7.5 Cup lift test The motorized tank moves up and engages the successful ! failed !<br />

upwards<br />

upper microswtich<br />

2.7.6 Cup lift test The motorized tank moves down and engages successful ! failed !<br />

downwards the lower microswtich<br />

2.7.7 Capp valve Check correct operation of the cappuccinatore successful ! failed !<br />

test<br />

and relative microswitch<br />

2.7.9 Multivalve Check correct operation of multivalve and relative successful ! failed !<br />

test<br />

microswitches<br />

2.7.10 Pump test Check pump and turbine operation.<br />

WARNING: hot water delivered<br />

successful ! failed !<br />

2.7.11 Grinder test Check coffee grinder and coffee presence, as<br />

well as hall sensor which counts pulses<br />

successful ! failed !<br />

2.7.12 Brew group Check ascent of unit and activation of the upper successful ! failed !<br />

test upwards limit microswitch<br />

2.7.13 Brew group Check descent of unit and activation of the lower successful ! failed !<br />

downwards limit microswitch.<br />

2.7.14 Water Check and inspection of power to coffee/ successful ! failed !<br />

heater test water heater, if the sensor detects increase in<br />

temperature.<br />

2.7.15 Steam Check and inspection of power to steam heater, successful ! failed !<br />

heater test<br />

(Touch Plus<br />

only)<br />

if the sensor detects increase in temperature.<br />

At the end of the automatic cycle, you can “repeat the automatic test “or “exit the test “as required”.<br />

Exit from diagnostics<br />

On selection of this option, the system exits the diagnostics menu and returns to the normal machine functions.<br />

PRIMEA Section 05<br />