Forschung und Entwicklung<br />

Seite<br />

1/2<br />

In this test we investigated the suitability of 1% and 2% working solutions of the <strong>terralin</strong> <strong>PAA</strong><br />

surface disinfectant for use in the schülke wipes mini-system.<br />

Test material: schülke wipes mini-system<br />

<strong>Schülke</strong> & <strong>Mayr</strong> GmbH 11157_1<br />

Robert-Koch-Str. 2 | 22851 Norderstedt | Postanschrift: 22840 Norderstedt<br />

Tel./Fax : +49 40 521 00 - 0/- 577 | mail@schuelke-mayr.com | www.schuelke.com<br />

(40 +1/-0 wipes per roll; 100% polyester; grammage > 45 g/m 2 )<br />

Test product: <strong>terralin</strong> <strong>PAA</strong> (1% and 2% working solution)<br />

Test design<br />

The schülke wipes mini-system was in each case filled with 3 litres of the different <strong>terralin</strong><br />

<strong>PAA</strong> working solutions (1% and 2%). To determine the concentration of the respective test<br />

samples, the working solution was pressed out of the wipe rolls after predefined standing<br />

times of 6, 8 and 12 hours and the concentration of peracetic acid was determined for these<br />

standing times.<br />

Results<br />

Usability of <strong>terralin</strong> <strong>PAA</strong><br />

in the schülke wipes mini-system<br />

Analysis of the tested 1% and 2% working solutions of <strong>terralin</strong> <strong>PAA</strong> in the schülke wipes<br />

mini-system revealed an adequate active-substance concentration of at least 90 ± 5% for<br />

both strengths at a storage temperature of 25 ± 2 o C. The disinfection performance of the


Seite 2/2<br />

tested working solutions in the schülke wipes mini-system is thus fully assured in connection<br />

with standing times encountered during the working day.<br />

Summary<br />

In this test we were able to show that the investigated working solutions of <strong>terralin</strong> <strong>PAA</strong> are<br />

suitable for use in the schülke wipes mini-system in connection with standing times<br />

encountered during the working day and that disinfection is fully assured when the product is<br />

used correctly.<br />

Thus <strong>terralin</strong> <strong>PAA</strong> is well suited for self-filling of the schülke wipes mini-system by the user.<br />

In order to ensure that the surfaces to be treated are adequately wetted, it is recommended<br />

that 3 litres of working solution is used per roll of 40 +1/-0 wipes.<br />

The hygiene requirements concerning the production and storage of disinfection solutions<br />

are to be observed. The water and vessels used for producing the disinfection solution<br />

should be in a satisfactory state of hygiene.<br />

This recommendation will not apply if any modifications have been made to the products<br />

mentioned above.<br />

Norderstedt, 15 th October 2010<br />

<strong>Schülke</strong> & <strong>Mayr</strong> GmbH<br />

Research & Development<br />

Dr. Katrin Steinhauer<br />

Head of Product Development Hygiene/Bioscience<br />

<strong>Schülke</strong> & <strong>Mayr</strong> GmbH<br />

Robert-Koch-Str. 2 | 22851 Norderstedt | Postanschrift: 22840 Norderstedt<br />

Tel./Fax : +49 40 521 00 - 0/- 577 | info@schuelke.com | www.schuelke.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!