Biometrics Ltd
Biometrics Ltd
Biometrics Ltd
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Minimum Computer<br />
Requirements:<br />
• Intel Pentium 1 GHz or higher<br />
• 128 MB RAM<br />
• 50 MB available hard disk<br />
space<br />
• CD ROM drive<br />
• SVGA color monitor<br />
• Serial port<br />
• Parallel port<br />
• Mouse & keyboard<br />
• Sound Card (Sound Blaster<br />
16 compatible)<br />
• Speakers<br />
• Operating system Windows<br />
2000 or XP<br />
• Graphics card (minimum 4<br />
MB memory)<br />
Documentation and<br />
Progress Reporting<br />
The report parameters are<br />
defined by the user and<br />
selected in the report window.<br />
The user may customize the<br />
report header and footer.<br />
Data Export<br />
Powerful export function with<br />
selectable parameters to<br />
quickly define the export<br />
criteria. Single or multiple<br />
patient data is exported as an<br />
ASCII file, easily imported into<br />
other applications for statistical<br />
analysis, outcomes reporting,<br />
and research studies.<br />
All products covered by this<br />
brochure have been<br />
independently certified to<br />
European Medical electrical<br />
Safety Standard EN60601-<br />
1:1990 and conform to the<br />
European Medical device<br />
Directive 93/42/EEC.<br />
<strong>Biometrics</strong> <strong>Ltd</strong><br />
Nine Mile Point Ind. Est.<br />
Gwent<br />
NP11 7HZ<br />
United Kingdom<br />
Tel: +44 1495 200 800<br />
Fax: +44 1495 200 806<br />
PO Box 340<br />
Ladysmith, VA<br />
22501<br />
USA<br />
Tel: +1 804 448 2520<br />
Fax: +1 804 448 0021<br />
North American toll free:<br />
800 543 6698<br />
Email: sales@biometricsltd.com<br />
Web: www.biometricsltd.com<br />
All the enclosed information is<br />
correct at the time of printing.<br />
<strong>Biometrics</strong> <strong>Ltd</strong> reserves the<br />
right to amend any specification<br />
without notice. <strong>Biometrics</strong> <strong>Ltd</strong><br />
Unique Solutions for Clinical and<br />
Research Applications<br />
Including:<br />
■ Active Resistive Upper<br />
Extremity Exercise<br />
■ Documentation &<br />
Progress Reporting<br />
■ Impairment Calculations<br />
NEW<br />
■ EMG Exercise<br />
■ Finger & Hand Exercise<br />
■ Lower Extremity Exercise<br />
<strong>Biometrics</strong> <strong>Ltd</strong>
E-LINK is a comprehensive range of products for computerized evaluation and<br />
exercise. Modules include electronic instrumentation for:<br />
■ Active & active resistive exercise of the upper extremity<br />
■ Active exercise of the lower extremity, back, and neck<br />
■ Isometric pinch and grip strength measurements and<br />
exercise<br />
■ EMG biofeedback and exercise<br />
■ Upper & lower extremity weight bearing exercise<br />
■ Range of Motion measurements<br />
E-LINK Database Software<br />
■ Create, store & retrieve patient records<br />
■ Contains standard diagnosis list modifiable by the user<br />
■ User defined fields – additional fields may be named and added<br />
to Patient Information, as well as some of the evaluation test<br />
screens<br />
■ Standard Text – paste often used text or templates into note<br />
fields. The text may be created in the E-LINK software or pasted in<br />
from other applications<br />
■ Database software with automated data collection for<br />
fast, accurate measurements, documentation, statistical<br />
analysis, and progress reporting<br />
■ Automatic calculation of Upper Extremity Impairment<br />
Rating using the AMA Guides to Permanent Impairment<br />
rev 4th and 5th editions and the Florida Uniform<br />
Permanent Impairment Rating Schedule<br />
■ Data Export – Selectable parameters quickly define the export<br />
criteria. Single or multiple patient data is exported as an ASCII file,<br />
easily imported into other applications for statistical analysis,<br />
outcomes reporting, or research studies<br />
■ Reports – comprehensive graphical, tabular and text colour<br />
reports with user selectable parameters<br />
■ Security features – multiple levels of users to restrict access to<br />
and protect the privacy of data collected.<br />
E-LINK Exercise<br />
Research shows when engaged<br />
in purposeful, activity based<br />
exercise – patients will exercise<br />
for a longer period, exhibit wider<br />
range of motion, report less<br />
pain, and in general rehabilitate<br />
faster.<br />
E-LINK takes this well proven<br />
concept of activity based<br />
exercise and incorporates it into<br />
a computer environment.<br />
The E-LINK parameters are set<br />
by the therapist, then the patient<br />
self exercises. The settings and<br />
results are saved in the patient’s<br />
record where they can be viewed<br />
by the therapist and printed on<br />
the report.<br />
E-LINK accommodates a<br />
wide range of patients: from<br />
Paediatrics to Geriatrics, in both<br />
Orthopaedic and Neurological<br />
settings.<br />
The E-LINK range of products<br />
and software for exercise cover<br />
the spectrum of rehabilitation<br />
needs:<br />
E-LINK Evaluation<br />
Computerized evaluation gives<br />
greater objectivity, accuracy,<br />
and speed of data collection<br />
and calculation.<br />
The E-LINK range of products<br />
and software for evaluation<br />
cover a variety of clinical<br />
applications from standard<br />
measurements done in almost<br />
every rehabilitation setting to<br />
comprehensive calculations<br />
done in specialized practices.<br />
■ E3000 Upper Limb Exerciser<br />
– active and active resistive<br />
exercise of the upper extremity.<br />
Variable ranges of movement and<br />
resistance for wrist, forearm,<br />
elbow, and shoulder exercise. The<br />
Upper Limb Exerciser also<br />
functions as the primary interface<br />
to the computer for the Myo-EX,<br />
Angle-X, Hand Kit, ROM Kit, and<br />
ForcePlate.<br />
■ L300 Lever Arm – tool used<br />
with the E3000 for elbow &<br />
shoulder exercises<br />
■ H400 Hand Kit – isometric<br />
pinch and grip exercises. As<br />
M400 Myo-EX<br />
■ H400 Hand Kit - electronic<br />
pinchmeter and dynamometer.<br />
Easily performs tests that cannot<br />
be done with manual instruments.<br />
■ R400 ROM Kit - small and<br />
large electronic goniometers.<br />
Quickly and accurately records<br />
range of motion measurements.<br />
■ ICSW Impairment<br />
Calculation Software -<br />
additional test screens for<br />
calculating Hand & Upper Extremity<br />
Impairment ratings.<br />
1 2<br />
opposed to traditional zero to peak<br />
force repetitive exercise, the range<br />
of force may be graded, setting<br />
the minimum and maximum, to<br />
meet the patient’s functional goals.<br />
The pinchmeter and dynamometer<br />
are also used for evaluation.<br />
■ M400 Myo-EX – uses the<br />
electrical activity generated by a<br />
muscle (surface electromyography<br />
or EMG) to control the activities.<br />
Useful for patients at a very early<br />
stage of rehabilitation, and for<br />
biofeedback and muscle reeducation<br />
of the upper & lower<br />
extremities, back, and neck.<br />
FP1 Force Plate<br />
■ ESW Evaluation Software -<br />
graphical and text documentation<br />
screens.<br />
R400<br />
M400 AngleX<br />
■ M400 AngleX – unique<br />
sensors for active exercise of<br />
any joint capable of movement<br />
against gravity. Used for finger,<br />
hand, upper extremity, lower<br />
extremity, back, head and neck<br />
movements.<br />
■ FP1 ForcePlate – general<br />
upper and lower extremity weight<br />
bearing exercise. As little as the<br />
touch of a finger through to full<br />
standing.<br />
■ S150 Small Tool Set –<br />
additional tools for the E3000,<br />
especially useful in Paediatrics<br />
and Hand Therapy.<br />
H400
E3000 Upper Limb Exerciser<br />
The E-LINK Upper Limb Exerciser is designed for active and active resistive<br />
upper extremity exercise. The various tools provide wrist flexion/extension,<br />
radial/ulnar deviation; forearm pronation/supination; elbow flexion/extension;<br />
shoulder flexion/extension, abduction/adduction, internal/external rotation.<br />
The Upper Limb Exerciser also functions as the primary interface to the<br />
computer for the Myo-EX, Angle-X, Hand Kit, ROM Kit, and ForcePlate.<br />
The versatility of the parameters allows rehabilitation for a<br />
wide range of orthopaedic and neurological patients.<br />
■ Range of motion used for exercise can be set as little as 2<br />
degrees, exercising patients with very little motion, through to full<br />
range of motion.<br />
■ The resistance can be adjusted, at the lowest level starting as<br />
soon as the patient<br />
is cleared for<br />
active exercise,<br />
increasing the<br />
resistance as the<br />
patient progresses<br />
through<br />
rehabilitation.<br />
■ The Activity<br />
Modules can be<br />
graded for speed<br />
and difficulty. This<br />
E300 with L300 Lever Arm<br />
allows a graduating<br />
course of therapy for each patient. The interactive Activity Modules<br />
engage the patient in the process, provide motivation and<br />
feedback, and eliminate the boredom associated with repetitive<br />
exercise.<br />
■ The versatility of the Activity Modules address a wide range of<br />
physical and cognitive needs. From simple end range to end range,<br />
gross motor activities to various type of matching and sequencing<br />
of objects to complex spatial relationships requiring fine motor<br />
control.<br />
Physical Rehabilitation to<br />
Restore Function for Patients<br />
with Limitations in Upper<br />
Extremity Use:<br />
■ Increase Range of Motion<br />
■ Increase Strength<br />
■ Increase Endurance<br />
■ Motor Learning and Control<br />
■ Tactile Sensitivity<br />
■ Velocity of Movement<br />
■ Positive Impact on Essential<br />
Activities of Daily Living<br />
■ Both Fine Motor and Gross<br />
Motor Activities<br />
Treatment for Patients with<br />
Neurologically Related<br />
Cognitive and Perceptual<br />
Deficits:<br />
■ Eye-hand Coordination<br />
■ Color Perception<br />
■ Spatial Perception<br />
■ Tracking & Scanning<br />
■ Sequencing of Activities<br />
■ Object Association<br />
■ Concentration<br />
■ Neuromuscular Re-education and<br />
Control<br />
■ Visual Field and Visual Attention Deficits<br />
S150 Small tool set<br />
H400 Hand Kit<br />
The <strong>Biometrics</strong>’ Hand Kit uses isometric grip and pinch force to control the<br />
activities in the exercise software. The dynamometer and pinchmeter also<br />
provide for accurate measurement of isometric grip and pinch strength,<br />
sustained grip and rapid exchange grip testing in either Kg or lbs.<br />
Grip & Pinch Strength Evaluation<br />
<strong>Biometrics</strong>’ computerised<br />
tools for strength<br />
evaluation and exercise<br />
measure in 0.1 increments<br />
(Kg or lbs) and include<br />
tests that cannot be done<br />
with manual devices. In<br />
addition to speeding up<br />
data collection, they are<br />
extremely sensitive<br />
providing accurate<br />
measurement on very<br />
weak or debilitated<br />
patients.<br />
The precision <strong>Biometrics</strong>’ dynamometer linked to the<br />
E-LINK software easily and accurately measures:<br />
■ Peak force in any or all of the five positions, up to three trials<br />
per position, with automatic calculation of average and coefficient<br />
of variation<br />
■ Sustained grip test measures force over time in 5, 10, 15, and 30<br />
second intervals and calculates peak force, time to peak, average, and<br />
fatigue rate<br />
■ Rapid exchange test, for detection of sub-maximal effort, is easily<br />
performed and the results documented in both graph and<br />
table form<br />
■ Progress reporting over multiple sessions, in both graph and table<br />
form, with calculation of percentage change from session to<br />
session, and comparison with standard Jamar normal values<br />
The unique low profile design of the <strong>Biometrics</strong>’ Pinchmeter allows<br />
measurement and exercise at closer to end range than any other<br />
device – manual or electronic. The software accurately and easily<br />
measures:<br />
■ Key (Lateral), Three Jaw (Tri-pod), Tip to Tip – three trials per<br />
position, calculates average and co-efficient of variation<br />
■ Progress reporting over multiple sessions, in both graph and table<br />
form, with calculation of percentage change from session to session<br />
3 4<br />
Isometric Pinch & Grip Exercise<br />
As opposed to traditional<br />
zero to peak force<br />
exercises, the range of<br />
force may be graded,<br />
setting the minimum and<br />
maximum, to meet the<br />
patient’s functional goals.<br />
Force ranges for exercise<br />
are set in 0.1 increments<br />
with a maximum load of<br />
90 Kg (200 lbs) for grip<br />
and 22 Kg (50 lbs) for<br />
pinch. The movement of<br />
the objects in the E-LINK Activity Modules is controlled by the<br />
application and relaxation of isometric grip or pinch within the set<br />
parameters. The various modules provide purposeful activity, isometric<br />
strengthening, motor learning and control.<br />
The range of force settings and activities allow multiple exercise<br />
options such as:<br />
■ Zero to peak force exercise, taking the patient from full relaxation to<br />
maximum, including the option to hold at peak force<br />
■ Exercise within patient limitations, setting the minimum at greater<br />
than zero, causing the patient to sustain the pinch or grip and control<br />
the force application and relaxation<br />
■ Setting the force range very low allows controlled purposeful activity<br />
while minimizing joint loading. This is useful for patients with Arthritis<br />
and other situations where low force on the joints is desirable<br />
■ By varying the range of force and time, the patient’s rehabilitation<br />
can be oriented to specific job or ADL goals<br />
■ The Activity Modules provide a range of effects – from gross<br />
isometrics strengthening to fine motor control<br />
The H400 requires either the E3000 Upper Limb Exerciser or the CX4<br />
Accessory Communications Unit as the interface to the computer.
M400 Exercise Kit<br />
The M400 Exercise Kit consists of sensors for surface EMG and active<br />
movement against gravity and provides unique rehabilitation opportunities<br />
by use of innovative technology. The M400 can be used very early in the<br />
rehabilitation process – as soon as the patient recovers any voluntary<br />
muscle control.<br />
The M400 Exercise Kit consists of the Myo-EX and AngleX sensors and requires<br />
either the E3000 Upper Limb Exerciser or the CX4 Accessory Communications Unit<br />
as the interface to the computer.<br />
The M400 is designed for:<br />
■ Orthopaedic and Neurological Rehabilitation<br />
■ Hand and Upper Extremity Exercise<br />
■ Lower Extremity Exercise<br />
■ Neck & Back Exercise<br />
Angle<br />
The innovative AngleX sensors respond to active movement against gravity,<br />
from very small amounts of movement such as lifting a finger off the table<br />
through to full range of joint movements. The movements control the objects<br />
in the E-LINK Activity Modules<br />
providing unique interactive exercise<br />
and biofeedback.<br />
The following movements<br />
for exercise are possible:<br />
■ Hand<br />
■ Fingers<br />
■ MCP, PIP, DIP<br />
➔ extension and flexion<br />
➔ individual joints (blocked)<br />
➔ full finger<br />
extension/flexion<br />
(composite fist)<br />
■ abduction and adduction<br />
The AngleX sensors are designed to<br />
be attached close to the joint to be<br />
exercised using double sided tape.<br />
The small size and light weight ensure<br />
the instrument does not interfere with<br />
normal joint movement.<br />
AngleX sensors come in two<br />
sizes.<br />
The small NC1 is designed for<br />
finger and hand exercises. The<br />
larger NC2 is designed for all<br />
other movement patterns.<br />
■ Thumb<br />
■ MCP, IP<br />
➔ extension and flexion<br />
➔ CMC<br />
➔ radial abduction<br />
➔ palmer abduction<br />
➔ adduction<br />
■ opposition<br />
■ Wrist<br />
■ extension and flexion<br />
■ radial and ulnar deviation<br />
■ Forearm<br />
■ pronation and supination<br />
■ Elbow<br />
■ flexion and extension<br />
■ Shoulder<br />
■ flexion and extension<br />
■ abduction and adduction<br />
■ internal and external rotation<br />
■ Neck and Back<br />
■ extension and flexion<br />
■ lateral flexion – left and right<br />
■ Lower Extremity<br />
■ Hip<br />
■ extension and flexion<br />
■ abduction and adduction<br />
■ internal and external rotation<br />
■ Knee<br />
■ extension and flexion<br />
■ Ankle<br />
■ dorsiflexion and<br />
plantarflexion<br />
■ inversion and eversion<br />
Myo-E<br />
Myo-EX uses surface EMG for unique computerised exercise and<br />
biofeedback.<br />
When a muscle contracts electrical activity is generated within the<br />
muscle that may be measured using electrodes placed on the surface<br />
of the skin. This electrical signal is usually in the order of up to 3,000<br />
micro volts and is referred to as<br />
electromyography or EMG.<br />
The Myo-EX EMG pre amplifier<br />
designed and manufactured by<br />
<strong>Biometrics</strong> has been developed<br />
with ease of use and quality of<br />
signal in mind. What this means<br />
in practice is that little or no skin<br />
preparation and no gels or<br />
creams are required, yet the<br />
quality of the signal is absolutely<br />
superb.<br />
FP1 ForcePlate<br />
ForcePlate for upper and lower extremity weight bearing exercise<br />
The E-LINK FP1 is designed for upper and lower extremity exercise. The<br />
Activity Modules are controlled by the application and relaxation of<br />
force applied and can be set in 0.1 increments (Kg or lbs).<br />
The ForcePlate responds to as little as the touch of a finger through<br />
to full standing weight bearing. The versatility of the ForcePlate<br />
allows rehabilitation for a wide range of orthopaedic and/or<br />
neurological patients.<br />
Orthopaedic applications include:<br />
■ Full or partial standing weight bearing for hip & knee<br />
rehabilitation<br />
■ Isometric ankle dorsiflexion/plantarflexion<br />
■ Hip adduction/abduction<br />
■ Upper extremity weight bearing for strengthening<br />
■ Wrist extension (isometric) to increase ROM<br />
■ Finger abduction<br />
5 6<br />
The electrical activity produced by<br />
the muscle is used to control the<br />
Activity Modules in the E-LINK<br />
software – providing a truly novel<br />
application for biofeedback and<br />
muscle re-education. Easily<br />
adjusted parameters enable use<br />
with a wide range of patients –<br />
from extremely debilitated through<br />
to professional athletes.<br />
While the full scale is 0 to<br />
3000 micro volts, neuro<br />
patients have successfully<br />
used the Myo-EX with as<br />
little as 9 micro volts of<br />
muscle activity.<br />
The Myo-EX comes with<br />
two styles of EMG Pre-amplifiers. The GX1 has integral electrodes and<br />
is applied over the body of small or large muscles using the die cut<br />
medical grade double sided adhesive tape. The GX2 is designed for use<br />
with disposable electrodes having a standard snap connector.<br />
Neurological applications include:<br />
■ Standing weight shifting<br />
■ Seated weight shifting<br />
■ Head and neck control for spinal cord injury patients<br />
■ Desensitisation - start with light touch, low force, short duration –<br />
increase force and duration as the patient tolerates<br />
■ Upper extremity weight bearing to facilitate transferring<br />
■ Gross motor control – use as a switch<br />
The FP1 ForcePlate requires either the<br />
E3000 Upper Limb Exerciser or the<br />
CX4 Accessory Communications Unit as<br />
the interface to the computer.
R400 ROM Kit<br />
Range of Motion Measurements – upper and lower<br />
extremity Speed and accuracy of data collection are<br />
greatly increased using the automated hand held<br />
goniometers – the goniometer is positioned on the joint<br />
and a press of the switch enters the data in 1°<br />
increments. The small goniometer is used for the hand;<br />
the large is for wrist, elbow, shoulder, hip, knee, and ankle.<br />
The R400 measures:<br />
■ Hand (fingers & thumb) – active & passive, extension & flexion,<br />
abduction & adduction, lateral deviations & rotational<br />
deformities, calculation of Total Active Motion and Total Passive<br />
Motion.<br />
■ Wrist – active & passive, extension & flexion, radial & ulnar<br />
deviation<br />
■ Forearm – active & passive, pronation & supination<br />
■ Elbow – active & passive, extension & flexion<br />
■ Shoulder – active & passive, extension & flexion, abduction &<br />
adduction, internal & external rotation<br />
■ Lower extremities – active & passive, hip, knee, & ankle<br />
■ Documentation of ankylosis and arthrodesis for the above joints<br />
Other ROM Measurement (entry of manually collected data)<br />
■ Tip to Palm<br />
■ Thumb Opposition<br />
■ Neck & Back<br />
Progress reporting over multiple sessions, in both graph and table<br />
form.<br />
The R400 requires either the E3000 Upper Limb Exerciser or the<br />
CX4 Accessory Communications Unit as the interface to the<br />
computer.<br />
ESW - Evaluation and<br />
ICSW - Impairment Software<br />
Comprehensive software for documentation of manually collected data and calculation<br />
of impairment increases speed and accuracy of data collection and reporting.<br />
Calculation of Upper Extremity Impairment using the AMA (American Medical<br />
Association) Guides to the Evaluation of Permanent Impairment (rev 4th & 5th editions)<br />
and the Florida Uniform Permanent Impairment Rating Schedule.<br />
The <strong>Biometrics</strong> Evaluation and Impairment Calculation Software<br />
modules provide standardised reporting with simple, fast data<br />
entry.<br />
ESW – Evaluation Software<br />
Documents the results of tests and data collected manually,<br />
including some that factor into the Impairment Ratings.<br />
■ Test Sequence – allows the user to set up testing protocols<br />
■ Amputation – graphical documentation.<br />
■ Coverage/comesis – graphical documentation of physical<br />
appearance.<br />
■ Sensation Tests – graphical documentation of Semmes Weinstein<br />
and Two point discrimination<br />
■ Pain<br />
■ Manual Muscle Test<br />
■ Oedema – circumferential and volumetric<br />
■ Provacative Diagnostic Tests<br />
■ Dexterity Tests<br />
ICSW – Impairment Software<br />
Documentation screens and tests primarily used to calculate AMA<br />
Impairment ratings. To obtain the complete Upper Extremity<br />
Impairment Rating, this software is used in conjunction with the<br />
H400 Hand Kit, R400 ROM Kit, and the ESW Evaluation software.<br />
Automatic calculation of impairment saves significant time over<br />
manual methods and prevents calculation errors.<br />
■ Major Nerve Injuries<br />
■ Vascular Disorders<br />
■ Other Bone & Joint Disorders<br />
■ Impairment Calculation<br />
The comprehensive Impairment Report provides both the summary<br />
values as well as detailed charts and text showing how the<br />
summary values were calculated. The Impairment Report also<br />
includes the ability to use the uninvolved side as the normal for<br />
calculation of ROM and Strength impairments and the option to not<br />
print any values for the uninvolved side.
The E-LINK Systems package together popular components in configurations tailored to meet<br />
a wide range of clinical applications and budgets.<br />
EP1 Evaluation &<br />
Exercise Package<br />
System for:<br />
◆ Upper & Lower Extremity Exercise<br />
◆ Back & Neck Exercise<br />
◆ Upper Extremity Evaluation<br />
◆ Upper Extremity Impairment Calculation<br />
◆ Comprehensive Documentation & Progress<br />
Reporting<br />
Includes:<br />
■ E3000 – Upper Limb Exerciser<br />
■ L300 – Lever Arm for elbow/shoulder exercise<br />
■ H400 – Grip & pinch measurement & exercise<br />
■ R400 – Upper & lower extremity range of motion measurements<br />
■ FP1 – Upper & lower extremity weight bearing exercise<br />
■ M400 – Myo-EX (whole body EMG for exercise) & AngleX (whole<br />
body active exercise against gravity)<br />
■ S150 – Small handle set for E300<br />
EP3 Exercise Package<br />
System for:<br />
◆ Upper & Lower Extremity Exercise<br />
◆ Back & Neck Exercise<br />
◆ Documentation & Reports<br />
Includes:<br />
■ E3000 – Upper Limb Exerciser<br />
■ L300 – Lever Arm for elbow/shoulder exercise<br />
■ H400 – Grip & pinch measurement & exercise<br />
■ FP1 – Upper & lower extremity weight bearing exercise<br />
■ M400 – Myo-EX (whole body EMG for exercise) & AngleX<br />
(whole body active exercise against gravity)<br />
■S150 – Small handle set for E3000<br />
The EP3 includes all components necessary to make one<br />
E-LINK exercise station using your own computer, printer, and<br />
table.<br />
CX4 Accessory Communications Unit<br />
The CX4 Accessory Communications Unit is designed to serve as<br />
an alternative interface to the computer for:<br />
H400 Hand Kit R400 ROM Kit<br />
M400 Exercise Kit ESW Evaluation Software<br />
FP1 ForcePlate ISCW Impairment<br />
Calculation Software<br />
Create stand alone systems for evaluation, exercise or both.<br />
9<br />
■ ESW Evaluation Software<br />
■ ICSW Impairment Calculation software<br />
The EP1 includes all components necessary to make one complete<br />
E-LINK evaluation and exercise station using your own computer,<br />
printer, and table.<br />
The CX4 also allows larger<br />
clinics to maximize their<br />
investment with a<br />
low cost expansion<br />
of hardware and<br />
software to make<br />
multiple<br />
workstations.<br />
EP5 Exercise Package<br />
System for:<br />
◆ Upper & Lower Extremity Exercise<br />
◆ Back & Neck Exercise<br />
◆ Documentation & Reports<br />
Includes:<br />
■ M400 – Myo-EX (whole body EMG for exercise) & AngleX<br />
(whole body active exercise against gravity)<br />
■ FP1 – Upper & lower extremity weight bearing exercise<br />
■ CX4 – Accessory Communications Unit<br />
The EP5 includes all components necessary to make one E-LINK<br />
exercise station using your own computer, printer, and table.<br />
V900S Stand Alone Evaluation System<br />
System for:<br />
◆ Upper Extremity Evaluation<br />
◆ Upper Extremity Impairment Calculation<br />
◆ Comprehensive Documentation & Progress Reporting<br />
Includes:<br />
■ H400 – Grip & pinch measurement & exercise<br />
■ R400 – Upper & lower extremity range of motion<br />
measurements<br />
■ ESW Evaluation Software<br />
■ ICSW Impairment Calculation Software<br />
■ CX4 – Accessory Communications Unit<br />
The V900S includes the E-LINK evaluation components to<br />
make one upper extremity evaluation and impairment<br />
calculation station using your own computer, printer, and<br />
table.<br />
<strong>Biometrics</strong>' products are used worldwide in a variety of clinical settings including:<br />
Orthopaedics ■ Hand Therapy ■ Geriatrics ■ Paediatrics ■ General Occupational<br />
and Physical Therapy ■ Schools ■ Sports Medicine ■ Neurology ■ Spinal Cord Injury<br />
■ Burn Centers ■ Stroke Rehab Units ■ Hospitals ■ Nursing Homes ■ Private Practices ■<br />
10