(N)HXH<br />
FE180/E30<br />
KERAM<br />
Halogen-Free Cable with<br />
Circuit Integrity of 30 Minutes<br />
Application: Safety cables are used in all locations where a high degree of protection<br />
against fire and fire-damage has to be provided for human life and equipment<br />
and are, therefore, subject to high security requirements. These cables may be<br />
used indoors and outdoors. They may not be installed directly into the ground<br />
and into the water. This cable conforms with Safety Class II standards.<br />
Functional integrity of 30 minutes and insulation integrity of 180 minutes.<br />
Construction: 1 ..... solid or stranded bare copper<br />
2 ..... core insulation of halogen-free, similar ceramic<br />
polymer compound (HXI 1)<br />
3 ..... halogen-free inner sheath<br />
4 ..... outer sheath of halogen-free polymere (HM4), orange<br />
Information: These cables fulfil the conditions of the tests to insulation integrity according to<br />
DIN VDE 0472-814/ 8.83 about 180 min. and IEC Public. 331 first edition 1970<br />
to circuit integrity about 30 min. to DIN 4102-12 according to VDE 0100-710<br />
and 0100-718.<br />
Standards: adapted to DIN VDE 0266<br />
DIN VDE 0276-604<br />
DIN VDE 0472-814<br />
DIN EN 60228 class 1 and 2 (construction)<br />
HD 308 S2 (core identification)<br />
Technical data:<br />
Nominal voltage Uo/U [V] 600 / 1000 Volt<br />
Test voltage [V]AC 4000<br />
Temperature range in motion -5°C till +90°C<br />
Operating temperature short circuit °C 250<br />
Short circuit time max. [sec] 5<br />
Bending radius single core style x diameter 15<br />
multi core style x diameter 12<br />
Flammability standard EN 50266-2-4<br />
IEC 60332-3 Kat.C<br />
Number of cores and<br />
nominal cross section<br />
mm�<br />
Price<br />
EUR / km<br />
J<br />
Price<br />
EUR / km<br />
O<br />
Copper<br />
figure<br />
kg/km<br />
Overall<br />
diameter<br />
appr.mm<br />
Calorific<br />
potential<br />
kWh/m<br />
Weight<br />
appr.<br />
kg/km<br />
1 x 16 RM 5.464,88 160 9,0 0,30 207<br />
1 x 25 RM 7.518,91 250 10,6 0,40 307<br />
1 x 35 RM 9.187,55 350 11,8 0,46 407<br />
1 x 50 RM 11.230,52 11.230,52 500 13,1 0,54 535<br />
1 x 70 RM 14.531,34 14.531,34 700 15,0 0,66 744<br />
1 x 95 RM 17.753,40 950 17,0 0,80 1.009<br />