Universal Remote<br />

Alarm Buzzer<br />

Features:<br />

M2-REM-AL-WALL<br />

M2-REM-AL-SURF<br />

The Remote Alarm Buzzer can be used in the<br />

following separate functions:<br />

• A device sending a dry contact signal.<br />

• An <strong>Amico</strong> Alert-2 area or master alarm.<br />

• An Alert-2 manifold bank switch-over occurs.<br />

General Speci� cations:<br />

The <strong>Amico</strong> Universal Remote Alarm Buzzer will provide the user<br />

with the ability to receive an audible alarm, and a visual alarm<br />

from a remote dry contact signal. If an alarm condition occurs,<br />

the “RED” alarm LED shall � ash and the audible alarm will sound.<br />

Pushing the “ALARM SILENCE” button will cancel the audible<br />

alarm, but the unit will remain in the visual alarm condition<br />

until the problem is recti� ed.<br />

The M2-REM-AL-NEMA includes a built in <strong>power</strong> supply that<br />

accepts 110 V AC to 240 V AC (50 to 60 Hz) as the input voltage.<br />

The output voltage is 12V DC.<br />

The M2-REM-AL-N2 includes two remote buzzers and a <strong>power</strong><br />

supply that accepts 110 V AC to 240V AC (50 to 60 Hz) as the<br />

input voltage and an output voltage of 12V DC.<br />

The M2-REM-AL-WALL and M2-REM-AL-SURF if used with an<br />

<strong>Amico</strong> Alert-2 Manifold or Alarm does not require a <strong>power</strong><br />

supply if the distance between the Universal Remote Buzzer<br />

and the Manifold or Alarm is less than 60 ft. If the distance is<br />

greater than 60 ft, an external <strong>power</strong> supply (A2P-POWER-CONV)<br />

or a 12 volt DC voltage is required.<br />

M2-REM-AL-NEMA<br />

M2-REM-AL-N2<br />

1


Technical Speci� cations<br />

M2-REM-AL-WALL<br />

5<br />

[127]<br />

3<br />

[76.2]<br />

5.5<br />

[139.7]<br />

M2-REM-AL-SURF<br />

4-7/16<br />

[127]<br />

M2-REM-AL-NEMA<br />

6<br />

[152.4]<br />

6<br />

[152.4]<br />

M2-REM-AL-N2<br />

8<br />

[203.2]<br />

2<br />

[51]<br />

2-7/8<br />

[73]<br />

4<br />

[101.6]<br />

4<br />

[101]<br />

6<br />

[152.4]<br />

4<br />

[101.6]<br />

wiring schematic<br />

AC �� ������ Supply<br />

��� 120 ��� VAC<br />

Optional Power Supply Power<br />

Supply<br />

12V DC<br />

+ -<br />

Optional Signal<br />

Device<br />

Dry Contact<br />

C NO NC<br />

+ - C NO NC<br />

<strong>Amico</strong> Corporation 85 Fulton Way, Richmond Hill, ON L4B 2N4, Canada I 71 East Industry Court, Deer Park , NY 11729, USA<br />

Toll Free Tel: 1.877.462.6426 | Toll Free Fax:1.866.440.4986 Tel: 905.764.0800 | Fax: 905.764.0862<br />

APE-SP-UNIVALMBUZZR PRINTED APR 09<br />

www.amico.com<br />

REMOTE BUZZER<br />

+<br />

S<br />

-<br />

annunciator wiring<br />

schematic<br />

��������� Optional: �� To <strong>Amico</strong> ����� Universal ���������<br />

Remote Buzzer<br />

������ ������<br />

REMOTE BUZZER<br />

+12V<br />

NO NC COM GND +12V<br />

Power Supply: A2P-POWER-CONV<br />

NOTE: Power supply not included with wall & surface mount<br />

wiring schematic<br />

AC Supply<br />

G G N L<br />

Power Supply<br />

Power Supply<br />

Optional Dry Contact Signal<br />

Device<br />

12V DC<br />

+ -<br />

C NO NC<br />

R1 �� R2 ��<br />

REMOTE BUZZER<br />

+<br />

- S<br />

G R2 R1<br />

G R2 R1<br />

Optional Signal<br />

Device<br />

Dry Contact<br />

REMOTE BUZZER<br />

+<br />

S<br />

-<br />

REMOTE BUZZER<br />

+ -<br />

+<br />

S<br />

-<br />

+ -<br />

Power Supply<br />

12V DC<br />

AC �� ������ Supply<br />

��� 120 ��� VAC<br />

Inch<br />

[mm]<br />

+<br />

S<br />

-<br />

annunciator wiring<br />

schematic<br />

Optional: ��������� To <strong>Amico</strong> �� ����� Universal ���������<br />

Remote ������ Buzzer������<br />

Power Supply<br />

12V DC<br />

+ -<br />

+ -<br />

NO NC COM GND +12V<br />

+12V<br />

REMOTE BUZZER<br />

NOTE: The Manifold can be<br />

connected from Normally<br />

Open to R1 or R2, but all<br />

appropriate connections<br />

(Common) should be<br />

made to Ground.<br />

+<br />

S<br />

-<br />

2