SL-90HS<br />

Ag0/Zn-Cell 1,5V - 90Ah<br />

Notes: The Information shown in this data sheet is for an<br />

individual cell.<br />

* After complete discharge.<br />

** Other currents on request.<br />

*** Cycle life is dependent on depth of discharge, standby<br />

time, temperature etc.<br />

**** Up to one month per year the storage temperature is<br />

allowed to be between -20ÆC and 45ÆC.<br />

14<br />

Technical Characteristics<br />

Nominal Capacity 90Ah<br />

Nominal Voltage 1,5V<br />

Minimum Charging Current 4,5A<br />

Maximum Charging Current 9A<br />

Charging Time*<br />

approx. 10h at 9A<br />

approx. 20h at 4,5A<br />

Cut off Voltage (COV) “charge” 2,08V +0/-0,03V<br />

Open Circuit Voltage (OCV)<br />

Application Loads** 90A, 450A<br />

Average Load Voltage at 1,50V at 90A<br />

Room Temperature 1,35V at 450A<br />

1,86V ±0,01V (fully charged)<br />

1,62V ±0,02V (partially discharged)<br />

Maximum Discharge Time 60 minutes at 90A<br />

at Room Temperature 10,5 minutes at 450A<br />

Cut off Voltage (COV) “discharge” min. 1,0V<br />

Electrolyte Potassium Hydroxide<br />

Typical Dry Storage life 5 Years<br />

Typical Wet Life Time 12 Month<br />

Typical Cycle Life*** 10 - 25 cycles<br />

Storage Temperature Range**** -15ÆC to +35ÆC<br />

Operating Temperature Range -10ÆC to +45ÆC<br />

Operate Cell Temperature max. +95ÆC at end of discharge<br />

Relative Humidity 45% to 75%<br />

Weight (filled) 1500g ± 50g<br />

Outline and Dimensions refer to drawing<br />

Tightening Torque of Pole Nuts 5 - 5,5Nm<br />

Tightening Torque of Cell Valve 2Nm<br />

Specification GERMAN MIL.STD. VG 95284-T10