RADOX ® 4 GKW-AX FR single core<br />

Conductor EN 60228, class 5 Voltage rating 1800/3000 V AC<br />

Number of conductors 1 2700/4500 V DC<br />

Cross section 1.5 - 120 mm 2 Temperature range -40 °C to +120 °C<br />

4 3 2 1<br />

Composition of cable<br />

1. Conductor stranded tin plated copper<br />

2. Flame barrier MICA tape<br />

3. Insulation RADOX GKW K<br />

4. Sheath RADOX GKW S, colour : black<br />

Characteristics and specialities<br />

• Meets requirement for circuit integrity in case of fire<br />

• Resistance to oil, ozone and weathering<br />

• Flexible<br />

• Easy to strip<br />

Application<br />

• For applications where circuit integrity is required.<br />

• Especially suitable as compact lead wires for systems inside railway rolling stock at fixed or sporadic moving<br />

installations.<br />

• Recommended for the installation are the standards EN 50355 and EN 50343.<br />

Standards<br />

Standard Fire protection on railway vehicles<br />

DIN 5510–2 Protection level 1, 2, 3, 4<br />

EN 50200<br />

Meets requirement for circuit integrity in<br />

case of fire<br />

For further technical details please refer to our data sheet.<br />

90 min. (1050 V)<br />