Table 7: <strong>Analysis</strong> Results, <strong>Energy</strong> Delivery System A<br />

False True Unknown Total<br />

DCL31-C 705 705<br />

DCL32-C 2 2 116 120<br />

DCL35-C 2 49 51<br />

DCL36-C 19 19<br />

EXP30-C 2 1 3<br />

EXP34-C 2 4 52 58<br />

EXP36-C 4 4 22 30<br />

EXP37-C 4 1 44 49<br />

INT31-C 1,999 1,594 3,593<br />

INT35-C 6 6<br />

FLP34-C 7 2 9<br />

FLP36-C 1 1<br />

ARR30-C 7 7<br />

STR31-C 3 3<br />

STR36-C 4 2 6<br />

STR37-C 1 1<br />

STR38-C 3 4 7<br />

MEM34-C 2 2<br />

FIO30-C 12 12<br />

ENV30-C 3 3<br />

SIG30-C 1 1<br />

CON33-C 1 1<br />

MSC31-C 1 1<br />

MSC34-C 6 2 579 587<br />

Total: 2,785 34 2,456 5,275<br />

The “False” and “True” columns document the number of flagged noncon<strong>for</strong>mities that were determined<br />

to be false and true positives, respectively. Normally it is sufficient to stop after finding<br />

one true positive, but in cases with a small number of flagged noncon<strong>for</strong>mities, all the results<br />

were evaluated to collect data about the true positive and flagged noncon<strong>for</strong>mity rates <strong>for</strong> the analyzer<br />

checkers. Flagged noncon<strong>for</strong>mities that were not evaluated are marked as “Unknown.”<br />

This particular energy control system violated at least 15 of the <strong>CERT</strong> C secure coding rules. In<br />

nine other cases, manual analysis eliminated possible rule violations as false positives.<br />

3.6.2 <strong>Energy</strong> Delivery System B<br />

The second energy delivery system was also evaluated by four static analysis tools supplemented<br />

by manual inspection. Two of the tools (analyzers A and B) were also used in the analysis of<br />

energy delivery system A. The other two analyzers were used <strong>for</strong> the first time in the analysis of<br />

energy delivery system B. Table 8 shows the flagged noncon<strong>for</strong>mities found from the analysis of<br />

the second energy delivery system.<br />