Part Number Key<br />
Size<br />
1<br />
ODU MINI-SNAP PC Contact Configurations<br />
Size 1, turned contacts<br />
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19<br />
1 *<br />
Standard Contact Configuration<br />
compatible <strong>with</strong> other manufacturers<br />
Special Contact Configuration<br />
not compatible <strong>with</strong> other manufacturers<br />
Positions<br />
Positions<br />
0 4<br />
Contact Ø mm<br />
(Termination cross section see page 47)<br />
Rated current (A)<br />
(Derating factor see page 54)<br />
Test voltage acc. VDE 0627:1986-06<br />
(kVrms)<br />
1 0 2 1,3 14 1,250 1,650 0,550<br />
Solder<br />
Crimp<br />
(Tools for assembly see page 66)<br />
PCB<br />
(PCB Layout and pin length on request)<br />
1 0 3 1,3 14 1,000 1,500 0,500 ● ● ●<br />
● ● ●<br />
1 0 5 0,9 10 0,875 1,350 0,450 ● ● ●<br />
1 0 6 0,7 7 0,875 1,300 0,433 ● ● ●<br />
1 0 7<br />
1 1 2<br />
1 0 8<br />
1 1 0<br />
1 1 4<br />
* If you use a standard contact configuration, so please insert a “0”.<br />
If you use a special contact configuration, so please insert a “9”.<br />
Test voltage acc. SAE AS13441:1998<br />
method 3001.1 (kVrms)<br />
0,9 10 1,000 1,500 0,500<br />
0,7 7 0,875 1,300 0,433<br />
0,5 5 0,875 1,200 0,400<br />
0,7 7 0,875 1,000 0,333<br />
0,5 5 0,875 1,000 0,333<br />
0,5 5 1,000 0,900 0,300<br />
● ● ●<br />
View on to termination area<br />
Pin Part Socket part<br />
Page 36 ODU Steckverbindungssysteme GmbH & Co. KG, Pregelstr. 11, D-84453 Mühldorf/Inn, Tel. +49/86 31/61 56-0, Fax +49/86 31/61 56 49, www.odu.de<br />
Rated voltage acc. SAE AS13441:1998<br />
method 3001.1 (kVrms) 1)<br />
Terminations<br />
(Surface<br />
see page 81)<br />
● ● ●<br />
● ●<br />
● ● ●<br />
● ●<br />
● ●<br />
1<br />
2<br />
2<br />
2<br />
3<br />
3<br />
2<br />
2<br />
3<br />
4<br />
4<br />
1<br />
4<br />
1<br />
1<br />
5<br />
1<br />
3<br />
5<br />
6<br />
2 7<br />
3 1<br />
6<br />
4 5<br />
5 4<br />
6 3 12<br />
7<br />
1<br />
2<br />
11<br />
8<br />
9<br />
10<br />
1) Rated voltage acc. SAE AS 13441:1998 method 3001.1 corresponded MIL-STD 1344, method 3001, test acc. IEC 60512 test 4a.<br />
calculation method, caution and suggestion see page 80<br />
3<br />
4<br />
3<br />
1<br />
5<br />
4<br />
3<br />
1<br />
2<br />
2<br />
2<br />
1<br />
1<br />
2<br />
1 2<br />
6<br />
3<br />
5 4<br />
7 2<br />
6<br />
1<br />
3<br />
5 4<br />
4 5<br />
12<br />
3 6<br />
11<br />
2<br />
1<br />
7<br />
10<br />
9<br />
8