VR-1A<br />
RR-2A<br />
VR-2A<br />
RR-1A<br />
Basic Variable Remote/Transmitter Kit (VR-1A)<br />
• Remote Flame Height Control<br />
Deluxe Variable Remote/Transmitter Kit (VR-2A)<br />
• Clock (Hours/Minutes)<br />
• Remote Flame Height Control<br />
• Room Temperature<br />
• Thermostatic Control<br />
Basic “On/Off” Remote/Transmitter Kit (RR-1A)<br />
• Remote “On/Off” Control<br />
Deluxe “On/Off” Remote/Transmitter Kit (RR-2A)<br />
• Clock (Hours/Minutes)<br />
• Remote “On/Off” Control<br />
• Room Temperature<br />
• Thermostatic Control<br />
Real-Fyre Remote Control Systems come with a <strong>gas</strong> valve, pilot assembly<br />
(for instant lighting), basic remote receiver and transmitter, and protective<br />
heat shield. The SPK/APK/EPK control Systems use no electricity, increase<br />
air flow to the valve, have heat shielding for greater protection, and include<br />
a built-in safety feature that shuts off <strong>gas</strong> flow should the pilot flame go<br />
out. All Peterson control systems are certified to ANSI Standards for<br />
Natural and Propane <strong>gas</strong>.<br />
For Valve Systems add suffix N for Natural or P for LP<br />
Model # PCDC-1<br />
Model # WCDC-1<br />
Optional Pine Cone or Wood<br />
Chunk decorative covers are<br />
available to conceal remote control<br />
receivers.<br />
Valve Features & Benefits Valve BTU Burner Compatibility Natural Gas Burner LP Burner<br />
APK-10 Large flow capacity, standing pilot 290,000 NAT G45 Series 18/20”-30” 18/20” - 30”<br />
Millivolt control valve 469,000 LP G5 Factory Assembled 16” - 36” 16” - 36”<br />
Can be used on All burner sizes<br />
RR-1A remote included<br />
G4 Series 12” - 60” 12” - 60”<br />
APK-11 Standing pilot light 70,000 NAT G45 Series 18/20” - 24” 18/20” - 30”<br />
Millivolt control valve 110,000 LP G5 Factory Assembled 16” - 24” 16” - 30”<br />
Low Profile<br />
RR-1A remote included<br />
G4 Series 12” - 24” 12” - 30”<br />
APK-15 Variable flame height, standing pilot 85,000 NAT G45 Series 18/20” - 30” 18/20” - 30”<br />
Piezo starter 135,000 LP G5 Factory Assembled 16” - 30” 16” - 36”<br />
VR-1A remote included G4 Series 12” - 30” 12” - 36”<br />
APK-16 Large flow capacity, standing pilot 240,000 NAT G45 Series 18/20” - 30” 18/20” - 30”<br />
Millivolt control valve 300,000 LP G5 Factory Assembled 16” - 36” 16” - 36”<br />
Can be used on All burner sizes<br />
PC-106 remote included<br />
Low Profile<br />
G4 Series 12” - 60” 12” - 60”<br />
SPK-26 Manual control 115,000 NAT G45 Series 18/20” - 30” 18/20” - 30”<br />
Standing pilot light 186,300 LP G5 Factory Assembled 16” - 36” 16” - 36”<br />
Low profile G4 Series 12” - 36” 12” - 60”<br />