Summary<br />

Table 2 Determination of Indices<br />

Index Method<br />

at = de/d(σ - ua) Constant-volume oedometer<br />

am = de/d(ua - uw) am = (am /bm) bm<br />

bt = dw/d(σ - ua) bt = at Gs<br />

bm = dw/d(ua - uw) Pressure plate test<br />

Ct = de/d log(σ - ua) Oedometer test<br />

Cm = de/d log(ua - uw) Cm = (Cm/Dm Gs ) Dm Gs<br />

Dt = dw/d log(σ - ua) Dt = Ct / Gs<br />

Dm = dw/d log(ua - uw) Pressure plate test<br />

am /bm Shrinkage test<br />

Cm/Dm Gs Shrinkage test<br />

Tests required for measurement of volume change indices<br />

for loading (one-dimensional tests)<br />

1) Oedometer Test - compute Ct then ⇒ Dt<br />

2) Pressure Plate Drying Test - compute Dm<br />

3) Shrinkage Test – compute Cm/Dm Gs then ⇒ Cm<br />

Tests required for measurement of volume change indices<br />

for unloading (one-dimensional tests)<br />

1) Oedometer Test (rebound) - compute Cts then⇒ D ts<br />

2) Pressure Plate Wetting Test - compute Dms<br />

3) Free Swell Test – compute Cms/Dms Gs then ⇒ Cms<br />