Features<br />

10<br />

Personal Dosimeter DKG-21<br />

Stand-alone use or use within the au<strong>to</strong>mated PC based system for personal<br />

dosimetry control.<br />

Dose accumulation his<strong>to</strong>ry s<strong>to</strong>rage in the non volatile memory with reference<br />

<strong>to</strong> real time.<br />

Dose accumulation his<strong>to</strong>ry transfer <strong>to</strong> a PC computer through the integrated<br />

infrared port.<br />

Power down prevention mode until all accumulated data has been read<br />

from the dosimeter.<br />

Gamma radiation EDR and ED threshold levels programming using on-line<br />

<strong>to</strong> a computer, control keys, or<br />

manually.<br />

The blocking of certain indication modes using computer<br />

commands on line.<br />

Light and audio alarm of exceeded programmed threshold level of gamma<br />

radiation EDR and ED.<br />

Au<strong>to</strong>matic digital display switch off if current gamma background<br />

is lower than the preset threshold level and<br />

Instant switch on when:<br />

- any control key pressed;<br />

- the gamma background increases above the preset threshold level;<br />

- when the alarm clock rings.<br />

Periodic self testing (batteries, detec<strong>to</strong>r).<br />

Energy compensated Geiger-Muller counter.<br />

Radiation Moni<strong>to</strong>rs<br />

Version 2.0<br />

Features<br />

Radiation Moni<strong>to</strong>r Terra<br />

Five independent measuring channels with alternate<br />

indication of data on the single liquid crystal display.<br />

Built-in gamma, beta sensitive Geiger-Muller counter.<br />

Prompt evaluation of gamma background within 10<br />

seconds.<br />

Au<strong>to</strong>matic subtraction of gamma background at<br />

measurement of beta contamination.<br />

Measurement results averaging, manually and<br />

au<strong>to</strong>matically.<br />

Au<strong>to</strong>matic setting of measurement intervals and ranges.<br />

Audio indication of each detected gamma-quantum and beta-particle<br />

(with switch off option).<br />

Two-<strong>to</strong>ne audio alarm of exceeded programmed<br />

threshold levels.<br />

Digital display backlight.<br />

Two AAA size batteries.<br />

Power supply discharge indication.<br />

Shock resistant frame.<br />

Small weight and dimension parameters.<br />

Measurement ranges and basic relative errors:<br />

Gamma and X-ray radiation<br />

equivalent dose rate (<br />

Measurement ranges and basic relative errors:<br />

Personal gamma radiation equivalent dose<br />

rate HP(10)<br />

Personal gamma radiation<br />

equivalent dose HP(10)<br />

Energy range of detected gamma and X-ray<br />

radiation and energy dependence<br />

µSv/h<br />

mSv<br />

MeV<br />

0.1…1 000 000;<br />

±15%<br />

0.001…9 999;<br />

±15%<br />

0.05…6.0;<br />

(0.05…1.25; ±25%)<br />

Recording resolution of dose<br />

minutes 5…255<br />

accumulation his<strong>to</strong>ry in the non volatile<br />

memory<br />

Time of data s<strong>to</strong>rage in the non volatile years not less than 10<br />

memory<br />

Data exchange rate through infrared port bit/s 38 400<br />

Positive data exchange distance between m not more than 0.3<br />

the dosimeter and infrared port adapter<br />

Lithium battery (CR2450) life<br />

Operating temperature range<br />

Weight<br />

Dimensions<br />

hours<br />

°C<br />

kg<br />

mm<br />

2 200<br />

-10…+50<br />

0.08<br />

86×54×9<br />

137 µSv/h 0.1…9 999;<br />

Cs):<br />

±15%<br />

Gamma and X-ray radiation<br />

equivalent dose ( 137 mSv 0.001…9 999;<br />

Cs):<br />

±15%<br />

Beta-particles flux density<br />

( 90 Sr+ 90 1/(cm²·min) 10…100 000;<br />

Y):<br />

±20%<br />

Equivalent dose accumulation time 1 min … 100 h;<br />

and accuracy of<br />

±0.1 s per 24 h<br />

measurement:<br />

Energy ranges of measurement and energy dependence:<br />

Gamma and X-ray radiation MeV 0.05…3.0;<br />

±25%<br />

Beta radiation MeV 0.5…3.0;<br />

Threshold level programming resolution<br />

for:<br />

µSv/h<br />

0.01<br />

- dose rate<br />

mSv<br />

0.01<br />

- dose<br />

10³/cm²·min 0.01<br />

- flux density<br />

Measurement time intervals<br />

Battery life<br />

Operating temperature range<br />

Weight<br />

Dimensions<br />

seconds<br />

hours<br />

°C<br />

kg<br />

mm<br />

1…70<br />

2 000<br />

-20…+50<br />

0.15<br />

120×52×26<br />