to view catalogue - Bartec technologies
to view catalogue - Bartec technologies
to view catalogue - Bartec technologies
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
delivering <strong>to</strong>morrow's<br />
technology <strong>to</strong>day<br />
Nuclear Scintigraphy Supplies And Accessories<br />
Catalogue
<strong>Bartec</strong> is Europe's leading supplier of Veterinary Nuclear Scintigraphy<br />
Equipment. <strong>Bartec</strong> provide new and refurbished Gamma cameras, processing<br />
computer systems software and all the necessary accessories. <strong>Bartec</strong> also<br />
offer building and preparation consultancy, installation and full user training.<br />
<strong>Bartec</strong> is a privately owned UK company with over thirty years of experience<br />
in the Nuclear Medicine and Nuclear Scintigraphy fields. <strong>Bartec</strong> are also the<br />
main UK distribu<strong>to</strong>r for Biodex accessories.<br />
<strong>Bartec</strong> Technologies Ltd<br />
Unit 8, Stanhope Gate<br />
Stanhope Road<br />
Camberley<br />
Surrey, GU15 3DW, UK<br />
���� +44 (0) 1276 20842<br />
Fax +44 (0) 1276 20891<br />
Email sales@bartec<strong>technologies</strong>.com<br />
Website: www.bartec<strong>technologies</strong>.com<br />
Version 2.0
Index<br />
Index<br />
<strong>Bartec</strong> Gamma Camera Systems 4<br />
Micas X Plus® Processing Systems 5<br />
Syringe Shields 6<br />
Vial Shields 7<br />
Table Top Shields 8<br />
Hazard Warnings 9<br />
Radiation Moni<strong>to</strong>rs 10<br />
Radiation Moni<strong>to</strong>rs 11<br />
Dose Calibra<strong>to</strong>r 12<br />
Decontamination 13<br />
<strong>Bartec</strong> are able <strong>to</strong> source many items not listed in this <strong>catalogue</strong>,<br />
please contact us for your special requests<br />
+44 (0) 1276 20842<br />
Version 2.0<br />
Page<br />
3
<strong>Bartec</strong> Gamma Camera System<br />
Jib Crane mounted<br />
Refurbished GE camera Overhead crane mounted<br />
Refurbished GE camera<br />
The <strong>Bartec</strong> Gamma Camera System is based on a new digital<br />
system or a fac<strong>to</strong>ry refurbished GE gamma camera detec<strong>to</strong>r and<br />
electronics. The detec<strong>to</strong>r is installed on a yoke and mounted<br />
on<strong>to</strong> a variety of transport systems including overhead Jib crane<br />
gantries , overhead gantry hoists and cus<strong>to</strong>m hydraulic Crane<br />
arms and stacker systems. The interconnecting detec<strong>to</strong>r cables<br />
are routed in such a way as <strong>to</strong> ensure that there are no trailing<br />
cables on the ground.<br />
The detec<strong>to</strong>r is completely sealed <strong>to</strong> ensure that no body fluids<br />
or contamination can enter. All units are designed for silent<br />
operation <strong>to</strong> ensure minimise distress for the horse.<br />
4 sales@bartec<strong>technologies</strong>.com<br />
Version 2.0<br />
Overhead crane mounted<br />
New Digital Rectangular Camera
MICASXPlus® Processing System<br />
Au<strong>to</strong>matic Motion Correction Software<br />
Before and After Motion Correction<br />
The <strong>Bartec</strong> MicasXPlus® Processor is an<br />
advanced Nuclear Medicine post processing<br />
system that has been developed in the UK for<br />
human imaging and has users all over the<br />
world. The system contains specific<br />
functionality for Nuclear Scintigraphy such as<br />
Horse motion correction as shown.<br />
The MicasXPlus® system provides all of the<br />
procedures and functionality required for<br />
<strong>to</strong>day's Nuclear Scintigraphy.<br />
<strong>Bartec</strong> has extensive experience in the field of Nuclear Scintigraphy and<br />
is able <strong>to</strong> provide advice and consultancy for new and existing<br />
projects. <strong>Bartec</strong> can also provide a complete package of camera,<br />
processor, accessories, installation and testing, full training for the Users,<br />
including health and safety and service on radiation protection matters.<br />
+44 (0) 1276 20842<br />
Version 2.0<br />
5
Syringe Shields<br />
Pro-Tec III Syringe Shield Pro-Tec II Syringe Shield<br />
The barrel of the shield is constructed of 2 mm thick<br />
tungsten that will reduce radiation exposure from Tc-<br />
99m by 94%. A 4.2 density lead glass window provides<br />
protection and visibility. The interior of the barrel behind<br />
the glass has a white coating that improves the<br />
<strong>view</strong> of the syringe and contents. A bevel around the<br />
lead glass helps protect it from scratching or breaking.<br />
The Safe-T-Lock design grips and secures the syringe<br />
upon insertion and will release the syringe at the press<br />
of a but<strong>to</strong>n. Disposing used syringes is easy; invert the<br />
syringe shield over a Sharps container, press the release<br />
but<strong>to</strong>n and the syringe freely disengages.<br />
Pro-Tec III® Syringe Shields:<br />
Syringe Shield, 5 ml 007-736<br />
Syringe Shield, 10 ml 007-738<br />
Shielded Syringe Carriers<br />
Safely s<strong>to</strong>res and transports syringes, on site, with either<br />
⅛” or ¼” lead lining.<br />
Syringe Carrier, Large, 3.2mm lead 001-179<br />
Syringe Carrier, Small, 3.2mm lead 001-181<br />
The Pro-Tec® II is thin, lightweight and easy <strong>to</strong> use.<br />
The barrel of the shield is constructed of 1.5 mm thick<br />
tungsten that will reduce radiation exposure from Tc-<br />
99m by 94%. A 4.2 density lead glass window provides<br />
protection and visibility. The interior of the barrel behind<br />
the glass has a white coating that improves the<br />
<strong>view</strong> of the syringe and contents. A clip secures the<br />
lead glass <strong>to</strong> the tungsten barrel and makes it easy <strong>to</strong><br />
replace scratched or broken glass. A stainless steel<br />
thumb screw holds syringes firmly in place.<br />
Pro-Tec® II Syringe Shields:<br />
Syringe Shield, 5 ml 007-900<br />
Syringe Shield, 10 ml 007-909<br />
Syringe Shield 20 ml 007-917<br />
Replacement Glass for Pro-Tec® II Syringe Shields:<br />
Syringe Shield Replacement Glass, 5 ml 127-789<br />
Syringe Shield Replacement Glass, 10 ml 127-999<br />
6 sales@bartec<strong>technologies</strong>.com<br />
Version 2.0<br />
Syringe Shield, 5 cc<br />
Syringe Shield 20 cc
Vial Shields<br />
Tungsten Vial Shield Colour Coded Vial Shields<br />
• Virtually unbreakable<br />
• Safe handling of radioactive liquids<br />
The Tungsten Vial Shield is designed <strong>to</strong> greatly reduce<br />
exposure <strong>to</strong> vials containing liquid radioiso<strong>to</strong>pes. The<br />
shield is constructed of .19" (.48 cm) thick tungsten,<br />
equivalent <strong>to</strong> .38" (1 cm) lead at 150 keV.<br />
Vials can be loaded from the <strong>to</strong>p or bot<strong>to</strong>m of the shield.<br />
A loss-proof slide injection port on the <strong>to</strong>p allows easy<br />
access <strong>to</strong> the vial septum.<br />
The <strong>to</strong>ugh tungsten will retain its shape under the<br />
roughest handling and is virtually unbreakable.<br />
Specifications<br />
Dimensions: 3.7 x 7 cm<br />
Inside Diameter: 2.5 cm<br />
Lead Equivalency: .1 cm<br />
Vial Shield, Tungsten, .38" lead equiv 053-805<br />
Colour coding is the easiest way <strong>to</strong> avoid a mix up.<br />
These vial shield colours match the C.I.S. kits and are<br />
compatible with most radiopharmaceutical vials. The<br />
body of the vial is constructed of .31" thick lead covered<br />
with a coloured acrylic collar.<br />
A 4.2 density lead glass window provides protection<br />
and visibility.<br />
Vials can be loaded from the <strong>to</strong>p or bot<strong>to</strong>m of the shield.<br />
The <strong>to</strong>p features an attached sliding lid for easy access<br />
<strong>to</strong> the vial septum.<br />
Specifications<br />
Dimensions: 4.3 x 7.8 cm<br />
I.D.: 2.7 cm<br />
Lead Shielding: .0.8 cm<br />
Weight: 0.9 kg<br />
Color-Coded Vial Shields without glass:<br />
Vial Shield, (Glucoscan), Red 053-601<br />
Vial Shield, (Osteolite,) Purple 053-602<br />
Vial Shield, (Pulmolite), Light orange 053-603<br />
Vial Shield, (Pyrolite), Blue 053-604<br />
Vial Shield, (Hepa<strong>to</strong>lite), Brown 053-605<br />
Vial Shield, (Microlite), Yellow 053-606<br />
Colour-Coded Vial Shields with glass:<br />
Vial Shield, (Glucoscan), Red 053-701<br />
Vial Shield, (Osteolite), Purple 053-702<br />
Vial Shield, (Pulmolite), Light orange 053-703<br />
Vial Shield, (Pyrolite), Blue 053-704<br />
Vial Shield, (Hepa<strong>to</strong>lite), Brown 053-705<br />
Vial Shield, (Microlite), Yellow 053-706<br />
+44 (0) 1276 20842<br />
Version 2.0<br />
7
Table Top Shields<br />
Standard Table Top Shield Mini Table Top Shield<br />
• Constructed of lead and lead glass<br />
• Integral stainless steel tray with spill proof lip<br />
• Optional bot<strong>to</strong>m and side shields available<br />
Specifications<br />
Table Top Shields<br />
Lead Shielding: 0.64 cm thick<br />
Dimensions: See drawings featured.<br />
Viewing Panel: 2.0 mm or 4.0 mm lead glass window<br />
Side Shields<br />
Lead Shielding: 0.64 cm thick<br />
Table<strong>to</strong>p Shields:<br />
Shield, Table Top, Standard, .5" lead 042-216<br />
With 2.0 mm lead glass<br />
Table<strong>to</strong>p Shield Lead Glass Panels:<br />
Lead Glass Panels can be paired <strong>to</strong> achieve 4.0 mm lead<br />
equivalency.<br />
Lead Glass Plate, 2.0 mm, Standard 017-121<br />
Side Shield, Standard, .25" lead 042-220<br />
Bot<strong>to</strong>m Shield, Standard, .125" lead 042-218<br />
• Constructed of lead and lead glass<br />
• Integral stainless steel tray with spill proof lip<br />
• Optional bot<strong>to</strong>m and side shields available<br />
Specifications<br />
Table Top Shields<br />
Lead Shielding: 0.64 cm thick<br />
Viewing Panel: 2.0 mm or 4.0 mm lead glass window<br />
Shield, Table Top, Mini, .5" lead 042-016<br />
With 2.0 mm lead glass<br />
Lead Glass Plate, 2.0 mm, Mini 017-810<br />
Side Shield, Mini, .25" lead 042-221<br />
Bot<strong>to</strong>m Shield, Mini, .125" lead 042-018<br />
8 sales@bartec<strong>technologies</strong>.com<br />
Version 2.0
Hazard Tape<br />
Hazard tape is a highly visible Magenta and Yellow<br />
warning tape that’s perfect for identifying physical<br />
hazard areas. Constructed of 6ml vinyl, the tape is durable<br />
<strong>to</strong> withstand long term placement.<br />
The tape will adhere <strong>to</strong> any clean smooth surface.<br />
Tape, Hazard 026-020<br />
Warning Rope<br />
• Brightly coloured—magenta and yellow<br />
• Triple– strand strength<br />
Made of high quality polypropylene, this triple strand<br />
rope assues high visibility and strength.<br />
Rope, Warning (price per foot) 121-072<br />
Diameter 0.8 cm<br />
Minimum order is 100’.<br />
Hazard Warnings<br />
Version 2.0<br />
Metal Signs<br />
Metal signs finished in heavy-duty baked enamel on<br />
30-gauge steel with holes for convenient attachment <strong>to</strong><br />
inner or outer doors.<br />
Caution radioactive materials 024-999<br />
Caution radiation Area 024-900<br />
Shipping Labels<br />
Pressure sensitive with peel off backing.<br />
Comply with fed eral Regulations, Title 49-<br />
Transportation of Hazard ous Materials Regulations,<br />
Dept. of Transportation, 49CFT, Part 173 as <strong>to</strong> wording,<br />
symbols.<br />
Label, Radioactive 1 white 20/pkg 030-001<br />
Label, Radioactive 2 Yellow 20/pkg 030-002<br />
Label, Radioactive 3 Yellow 20/pkg 030-003<br />
+44 (0) 1276 20842<br />
9
Features<br />
10<br />
Personal Dosimeter DKG-21<br />
Stand-alone use or use within the au<strong>to</strong>mated PC based system for personal<br />
dosimetry control.<br />
Dose accumulation his<strong>to</strong>ry s<strong>to</strong>rage in the non volatile memory with reference<br />
<strong>to</strong> real time.<br />
Dose accumulation his<strong>to</strong>ry transfer <strong>to</strong> a PC computer through the integrated<br />
infrared port.<br />
Power down prevention mode until all accumulated data has been read<br />
from the dosimeter.<br />
Gamma radiation EDR and ED threshold levels programming using on-line<br />
<strong>to</strong> a computer, control keys, or<br />
manually.<br />
The blocking of certain indication modes using computer<br />
commands on line.<br />
Light and audio alarm of exceeded programmed threshold level of gamma<br />
radiation EDR and ED.<br />
Au<strong>to</strong>matic digital display switch off if current gamma background<br />
is lower than the preset threshold level and<br />
Instant switch on when:<br />
- any control key pressed;<br />
- the gamma background increases above the preset threshold level;<br />
- when the alarm clock rings.<br />
Periodic self testing (batteries, detec<strong>to</strong>r).<br />
Energy compensated Geiger-Muller counter.<br />
Radiation Moni<strong>to</strong>rs<br />
Version 2.0<br />
Features<br />
Radiation Moni<strong>to</strong>r Terra<br />
Five independent measuring channels with alternate<br />
indication of data on the single liquid crystal display.<br />
Built-in gamma, beta sensitive Geiger-Muller counter.<br />
Prompt evaluation of gamma background within 10<br />
seconds.<br />
Au<strong>to</strong>matic subtraction of gamma background at<br />
measurement of beta contamination.<br />
Measurement results averaging, manually and<br />
au<strong>to</strong>matically.<br />
Au<strong>to</strong>matic setting of measurement intervals and ranges.<br />
Audio indication of each detected gamma-quantum and beta-particle<br />
(with switch off option).<br />
Two-<strong>to</strong>ne audio alarm of exceeded programmed<br />
threshold levels.<br />
Digital display backlight.<br />
Two AAA size batteries.<br />
Power supply discharge indication.<br />
Shock resistant frame.<br />
Small weight and dimension parameters.<br />
Measurement ranges and basic relative errors:<br />
Gamma and X-ray radiation<br />
equivalent dose rate (<br />
Measurement ranges and basic relative errors:<br />
Personal gamma radiation equivalent dose<br />
rate HP(10)<br />
Personal gamma radiation<br />
equivalent dose HP(10)<br />
Energy range of detected gamma and X-ray<br />
radiation and energy dependence<br />
µSv/h<br />
mSv<br />
MeV<br />
0.1…1 000 000;<br />
±15%<br />
0.001…9 999;<br />
±15%<br />
0.05…6.0;<br />
(0.05…1.25; ±25%)<br />
Recording resolution of dose<br />
minutes 5…255<br />
accumulation his<strong>to</strong>ry in the non volatile<br />
memory<br />
Time of data s<strong>to</strong>rage in the non volatile years not less than 10<br />
memory<br />
Data exchange rate through infrared port bit/s 38 400<br />
Positive data exchange distance between m not more than 0.3<br />
the dosimeter and infrared port adapter<br />
Lithium battery (CR2450) life<br />
Operating temperature range<br />
Weight<br />
Dimensions<br />
hours<br />
°C<br />
kg<br />
mm<br />
2 200<br />
-10…+50<br />
0.08<br />
86×54×9<br />
137 µSv/h 0.1…9 999;<br />
Cs):<br />
±15%<br />
Gamma and X-ray radiation<br />
equivalent dose ( 137 mSv 0.001…9 999;<br />
Cs):<br />
±15%<br />
Beta-particles flux density<br />
( 90 Sr+ 90 1/(cm²·min) 10…100 000;<br />
Y):<br />
±20%<br />
Equivalent dose accumulation time 1 min … 100 h;<br />
and accuracy of<br />
±0.1 s per 24 h<br />
measurement:<br />
Energy ranges of measurement and energy dependence:<br />
Gamma and X-ray radiation MeV 0.05…3.0;<br />
±25%<br />
Beta radiation MeV 0.5…3.0;<br />
Threshold level programming resolution<br />
for:<br />
µSv/h<br />
0.01<br />
- dose rate<br />
mSv<br />
0.01<br />
- dose<br />
10³/cm²·min 0.01<br />
- flux density<br />
Measurement time intervals<br />
Battery life<br />
Operating temperature range<br />
Weight<br />
Dimensions<br />
seconds<br />
hours<br />
°C<br />
kg<br />
mm<br />
1…70<br />
2 000<br />
-20…+50<br />
0.15<br />
120×52×26<br />
sales@bartec<strong>technologies</strong>.com
Radiation Moni<strong>to</strong>rs<br />
Thermo Scientific Mini 900 Survey Moni<strong>to</strong>r<br />
The Mini-moni<strong>to</strong>r serves as a portable or bench <strong>to</strong>p style radiation counter available with a variety of different<br />
probes <strong>to</strong> accommodate radiation detection needs. <strong>Bartec</strong> offer this product with the Type 44A Scintillation<br />
Probe for accurate detection of Tc-99m contamination in Veterinary Practices and Hospitals. The unit is packaged<br />
in durable, lightweight aluminium case, powered either from it’s internal battery pack or from mains power. The unit<br />
contains an internal constant current charger for its rechargeable batteries. Radiation Measurement read-out is on<br />
a large easy <strong>to</strong> <strong>view</strong> logarithmically scaled meter. An alarm can be set <strong>to</strong> trigger at any User selected level on the<br />
scale.<br />
Specifications:<br />
Weight: 1 kg (2.2 lbs)<br />
Size: 180 x 110 x 165 mm (7” x 4.5” x 6.5”)<br />
Batteries: 6 type AA cells, alkaline (IEC LR6) or rechargeable (IEC KR 15/51)<br />
Battery Life: Approximately 300 hours at 4hours/day<br />
Paralysis Time: Scale corrected <strong>to</strong> give true reading<br />
Meter Integration Time: 1 <strong>to</strong> 4 seconds set <strong>to</strong> match counting rate<br />
Radiation detec<strong>to</strong>r: Type 44A Sodium iodide crystal (32 mm dia. by 2.5 mm thick) mounted on the front<br />
surface of the probe <strong>to</strong> facilitate moni<strong>to</strong>ring of large contaminated areas. Suitable for a<br />
range of energies from approximately 15 keV <strong>to</strong> 250 keV. It is also beta sensitive for<br />
energies above 500 keV. Diameter 50 mm Length 180 mm. Aluminum window weight<br />
14 mg cm -2 .<br />
Radiation Detected: Gamma and X-Rays only<br />
Overload Protection: No meter “fallback” with intensities at least 100 times full scale reading<br />
Main Power: 12-18 VDC from mains converter unit<br />
+44 (0) 1276 20842<br />
Version 2.0<br />
11
Designed for facilities receiving unit<br />
doses<br />
Features at a glance:<br />
• Large, easy <strong>to</strong> read backlit LCD<br />
• Au<strong>to</strong>matic range selection; ranges up <strong>to</strong> 40 curies of<br />
Tc-99m<br />
• Pre-programmed for 88 most commonly used<br />
radionuclides<br />
• Displays in curies or becquerels<br />
• Small footprint for an economic workspace<br />
• Ultra-fast response<br />
• Self Diagnostic Software<br />
• Remote Ionisation Chamber<br />
• RS-232 bi-directional serial communications port<br />
Dose Calibra<strong>to</strong>r<br />
The RS-232 port enables the A<strong>to</strong>mlab 400 Dose Calibra<strong>to</strong>r <strong>to</strong><br />
communicate with most commercially available nuclear medicine<br />
management systems.<br />
The A<strong>to</strong>mlab 400 provides fast, accurate radionuclide activity<br />
measurements with performance that easily complies with the most<br />
stringent regula<strong>to</strong>ry requirements. The unit is simple <strong>to</strong> operate.<br />
There is a routine list of ten pre-programmed iso<strong>to</strong>pes plus another<br />
seven that can be user defined. Any four iso<strong>to</strong>pes will be displayed<br />
at a time. The A<strong>to</strong>mlab 400 display can be mounted on a wall or<br />
placed on a desk<strong>to</strong>p. In addition, there is a library containing 88<br />
iso<strong>to</strong>pes listed alphabetically, including Y-90 and Sr-89. Activity is<br />
displayed on an LCD panel in either Curie or Becquerel units.<br />
Background correction is performed at the <strong>to</strong>uch of a but<strong>to</strong>n. Range<br />
selection is au<strong>to</strong>matic. Activity measurements are performed by a<br />
microprocessor-controlled electrometer located within the detec<strong>to</strong>r<br />
assembly of the ionisation chamber. The chamber is shielded<br />
with .25" (6.3 mm) lead. It can be located up <strong>to</strong> eight feet away from<br />
the display unit. Chamber bias is generated within the display unit<br />
by an electronic high voltage supply, eliminating the need for<br />
Dose Calibra<strong>to</strong>r, A<strong>to</strong>mlab 400 , 230V 086-335<br />
Includes Vial/Syringe Dipper and Well Insert<br />
Optional Items<br />
086-423 Moly Shield, Vial 0.3” lead<br />
086-435 Moly Shield, Syringe 0.3” lead<br />
086-509 Linea<strong>to</strong>r<br />
086-242 Vial/Syringe Dipper<br />
086-241 Well Insert<br />
12<br />
A<strong>to</strong>mlab 400 Dose Calibra<strong>to</strong>r<br />
sales@bartec<strong>technologies</strong>.com<br />
Version 2.0<br />
SPECIFICATIONS<br />
Iso<strong>to</strong>pe Selection Keys: Ten pre-programmed – Tc-99m,<br />
Co-57, Cs-137, I-131, In-111, Ga-67, Xe-133, I-123, Tl-201,<br />
and Mo-99; seven additional keys for user-set iso<strong>to</strong>pes; two<br />
new iso<strong>to</strong>pe keys and a full alphabetical list of 88 iso<strong>to</strong>pes<br />
Activity Range: 0.1 µCi <strong>to</strong> 40Ci (.001 mBq <strong>to</strong> 1500 GBq) of<br />
Tc-99m<br />
Energy Range: 25 keV <strong>to</strong> 3 MeV pho<strong>to</strong>ns<br />
Response Time: One <strong>to</strong> two seconds for doses greater than<br />
200 uCi; three seconds for doses greater than 20 uCi; 50-100<br />
seconds below 20 uCi of Tc-99m with default threshold,<br />
threshold adjustable <strong>to</strong> reduce counting time<br />
Detec<strong>to</strong>r Linearity: ±1% or 0.2 µCi, whichever is greater<br />
Electrometer Linearity: ±1% or 0.2 µCi, whichever is greater<br />
Electrometer Accuracy: ±1% or 0.2 µCi, whichever is greater<br />
Overall Accuracy: ±3% or 0.3 µCi, whichever is greater; overall<br />
accuracy is affected by such fac<strong>to</strong>rs as the accuracy of the<br />
specific source calibration, geometric variations due <strong>to</strong> sample<br />
volume or configuration, detec<strong>to</strong>r linearity, electrometer<br />
accuracy and readout accuracy<br />
Repeatability: ±0.3% above 1 mCi short term (24 hr); 1% long<br />
term (one yr); exclusive of background<br />
Digital Calibration Dial: Four-digit LED dial display with<br />
increment/decrement keys <strong>to</strong> change the value; range is from<br />
0.0 <strong>to</strong> 999.9<br />
Detec<strong>to</strong>r: Well-type pressurized ionization chamber, with<br />
Argon fill gas; well opening 2.75" (7 cm), well depth 10.25" (26<br />
cm)<br />
Chamber Gas Pressure: 149KPa gauge (21.6 psig) at 20<br />
degrees C or 250KPa absolute (36.3 psia) at 20 degrees<br />
C. IATA regulation 3.2.2.4 Exempts Gases of Division 2.2<br />
from Dangerous Goods Regulations when transported at<br />
pressure less than 200KPa gauge (29 psig) at 20 degrees<br />
C. Device is shipped standard goods.<br />
Detec<strong>to</strong>r Shielding: .25" (6.3 mm) lead on all sides except <strong>to</strong>p<br />
well opening; supplementary shielding available<br />
Chamber Bias: 355 ± 5 volts<br />
Environmental Operating Conditions:<br />
Temperature: 0-40° C<br />
Humidity: 0-90% rh, non-condensing<br />
Power Requirements: 100 <strong>to</strong> 240 VAC, 0.6 – 0.3 amps, au<strong>to</strong><br />
switching; APS Power Supply (APS22ES-150160), for medical<br />
use<br />
Line Frequency: 50/60 Hz; detachable line cord; built-in EMI<br />
filter and transient suppression<br />
Detec<strong>to</strong>r and Interface Cables: 8' (243 cm) long, six<br />
conduc<strong>to</strong>r cables (two carry power, two for chassis ground, two<br />
carry serial data for digital I/O)<br />
Display Unit:<br />
Dimensions: 6.75" w x 6" depth x 5" h (17.1 x 15.3 x 12.7 cm)<br />
Weight: 3.6 lb (1.64 kg); desk<strong>to</strong>p or wall mountable<br />
Detec<strong>to</strong>r Unit:<br />
Dimensions: 6" dia x 15.5" h (15.24 x 39.37 cm)<br />
Well I.D.: 2.75" dia x 10.5" h (7 x 26.7 cm)<br />
Well I.D. with Liner: 2.5" dia x 10.25" h (6.35 x 26 cm)<br />
Lead Shielding: .25" thick (6.3 mm)<br />
Weight: 35 lb (16 kg)
Radiacwash<br />
Radiacwash has been in use since 1951 it is the most<br />
popular general-purpose decontamination solution<br />
specifically created for the fast and safe removal of<br />
liquid radioactive contaminants. Firstly, it sequesters<br />
metallic ions, which contaminate surfaces. Secondly, it<br />
lifts up and firmly suspends contaminating particles.<br />
Allowing contamination <strong>to</strong> be absorbed and then<br />
rinsed away with water.<br />
Radicawash, Spray Mist, 1 L bottle 005-400<br />
Radiacwash, Bottle 1 gal* 005-100<br />
Radiacwash, carboy w/spigot, 5 gal* 005-105<br />
Radiacwash, drum, 55 gal* 005-155<br />
*US gallon<br />
Radiacwash Towelettes<br />
Radiacwash Towelettes are the most efficient and safest<br />
way <strong>to</strong> remove radioactive contamination from hands<br />
and small objects. Simply remove the <strong>to</strong>welette from the<br />
foli packet, scrub hands thoroughly and wash the contamination<br />
away with running water.<br />
Radicawash, Towelettes 100/box 005-300<br />
Decontamination<br />
+44 (0) 1276 20842 13<br />
Version 2.0<br />
Decontamination kit<br />
The A<strong>to</strong>mlab Decontamination Kit contains all the<br />
equipment needed <strong>to</strong> cope with a radioactive spill or<br />
routine decontamination problem in the labora<strong>to</strong>ry.<br />
The drum serves as a container for the kit components<br />
and as waste transfer/s<strong>to</strong>rage vessel.<br />
Contents of Kit<br />
Quantity Cat No Item<br />
1 - 30 gallon fibre drum<br />
2 prs 118-125 Large coverall<br />
2 prs 119-200 Shoe covers<br />
2 120-530 Respira<strong>to</strong>rs<br />
4 120-750 Filters<br />
2 prs 034-005 Gloves<br />
1 gal 005-100 Radiacwash<br />
1 box 005-300 Radiacwash Towelettes<br />
1 bottle 005-400 Radiacwash spray Mist, 1 Litre<br />
10 040-108 Poly Bags<br />
1 001-012 12” Nip<strong>to</strong>ng<br />
1 ea Sponge, mop,scrub brush, pail,<br />
rope,assorted signs<br />
Decontamination Kit 121-180
<strong>Bartec</strong> Technologies Limited, Unit 8, Stanhope Gate, Stanhope Road, Camberley, Surrey, GU15 3DW, UK.<br />
Tel: 01276 20842 • Fax: 01276 20891 • sales@bartec<strong>technologies</strong>.com • www.bartec<strong>technologies</strong>.com<br />
<strong>Bartec</strong> Technologies Ltd, Avenue des Mouettes 14, Bruxelles 1150, Belgium.