14.01.2013 Views

to view catalogue - Bartec technologies

to view catalogue - Bartec technologies

to view catalogue - Bartec technologies

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

delivering <strong>to</strong>morrow's<br />

technology <strong>to</strong>day<br />

Nuclear Scintigraphy Supplies And Accessories<br />

Catalogue


<strong>Bartec</strong> is Europe's leading supplier of Veterinary Nuclear Scintigraphy<br />

Equipment. <strong>Bartec</strong> provide new and refurbished Gamma cameras, processing<br />

computer systems software and all the necessary accessories. <strong>Bartec</strong> also<br />

offer building and preparation consultancy, installation and full user training.<br />

<strong>Bartec</strong> is a privately owned UK company with over thirty years of experience<br />

in the Nuclear Medicine and Nuclear Scintigraphy fields. <strong>Bartec</strong> are also the<br />

main UK distribu<strong>to</strong>r for Biodex accessories.<br />

<strong>Bartec</strong> Technologies Ltd<br />

Unit 8, Stanhope Gate<br />

Stanhope Road<br />

Camberley<br />

Surrey, GU15 3DW, UK<br />

���� +44 (0) 1276 20842<br />

Fax +44 (0) 1276 20891<br />

Email sales@bartec<strong>technologies</strong>.com<br />

Website: www.bartec<strong>technologies</strong>.com<br />

Version 2.0


Index<br />

Index<br />

<strong>Bartec</strong> Gamma Camera Systems 4<br />

Micas X Plus® Processing Systems 5<br />

Syringe Shields 6<br />

Vial Shields 7<br />

Table Top Shields 8<br />

Hazard Warnings 9<br />

Radiation Moni<strong>to</strong>rs 10<br />

Radiation Moni<strong>to</strong>rs 11<br />

Dose Calibra<strong>to</strong>r 12<br />

Decontamination 13<br />

<strong>Bartec</strong> are able <strong>to</strong> source many items not listed in this <strong>catalogue</strong>,<br />

please contact us for your special requests<br />

+44 (0) 1276 20842<br />

Version 2.0<br />

Page<br />

3


<strong>Bartec</strong> Gamma Camera System<br />

Jib Crane mounted<br />

Refurbished GE camera Overhead crane mounted<br />

Refurbished GE camera<br />

The <strong>Bartec</strong> Gamma Camera System is based on a new digital<br />

system or a fac<strong>to</strong>ry refurbished GE gamma camera detec<strong>to</strong>r and<br />

electronics. The detec<strong>to</strong>r is installed on a yoke and mounted<br />

on<strong>to</strong> a variety of transport systems including overhead Jib crane<br />

gantries , overhead gantry hoists and cus<strong>to</strong>m hydraulic Crane<br />

arms and stacker systems. The interconnecting detec<strong>to</strong>r cables<br />

are routed in such a way as <strong>to</strong> ensure that there are no trailing<br />

cables on the ground.<br />

The detec<strong>to</strong>r is completely sealed <strong>to</strong> ensure that no body fluids<br />

or contamination can enter. All units are designed for silent<br />

operation <strong>to</strong> ensure minimise distress for the horse.<br />

4 sales@bartec<strong>technologies</strong>.com<br />

Version 2.0<br />

Overhead crane mounted<br />

New Digital Rectangular Camera


MICASXPlus® Processing System<br />

Au<strong>to</strong>matic Motion Correction Software<br />

Before and After Motion Correction<br />

The <strong>Bartec</strong> MicasXPlus® Processor is an<br />

advanced Nuclear Medicine post processing<br />

system that has been developed in the UK for<br />

human imaging and has users all over the<br />

world. The system contains specific<br />

functionality for Nuclear Scintigraphy such as<br />

Horse motion correction as shown.<br />

The MicasXPlus® system provides all of the<br />

procedures and functionality required for<br />

<strong>to</strong>day's Nuclear Scintigraphy.<br />

<strong>Bartec</strong> has extensive experience in the field of Nuclear Scintigraphy and<br />

is able <strong>to</strong> provide advice and consultancy for new and existing<br />

projects. <strong>Bartec</strong> can also provide a complete package of camera,<br />

processor, accessories, installation and testing, full training for the Users,<br />

including health and safety and service on radiation protection matters.<br />

+44 (0) 1276 20842<br />

Version 2.0<br />

5


Syringe Shields<br />

Pro-Tec III Syringe Shield Pro-Tec II Syringe Shield<br />

The barrel of the shield is constructed of 2 mm thick<br />

tungsten that will reduce radiation exposure from Tc-<br />

99m by 94%. A 4.2 density lead glass window provides<br />

protection and visibility. The interior of the barrel behind<br />

the glass has a white coating that improves the<br />

<strong>view</strong> of the syringe and contents. A bevel around the<br />

lead glass helps protect it from scratching or breaking.<br />

The Safe-T-Lock design grips and secures the syringe<br />

upon insertion and will release the syringe at the press<br />

of a but<strong>to</strong>n. Disposing used syringes is easy; invert the<br />

syringe shield over a Sharps container, press the release<br />

but<strong>to</strong>n and the syringe freely disengages.<br />

Pro-Tec III® Syringe Shields:<br />

Syringe Shield, 5 ml 007-736<br />

Syringe Shield, 10 ml 007-738<br />

Shielded Syringe Carriers<br />

Safely s<strong>to</strong>res and transports syringes, on site, with either<br />

⅛” or ¼” lead lining.<br />

Syringe Carrier, Large, 3.2mm lead 001-179<br />

Syringe Carrier, Small, 3.2mm lead 001-181<br />

The Pro-Tec® II is thin, lightweight and easy <strong>to</strong> use.<br />

The barrel of the shield is constructed of 1.5 mm thick<br />

tungsten that will reduce radiation exposure from Tc-<br />

99m by 94%. A 4.2 density lead glass window provides<br />

protection and visibility. The interior of the barrel behind<br />

the glass has a white coating that improves the<br />

<strong>view</strong> of the syringe and contents. A clip secures the<br />

lead glass <strong>to</strong> the tungsten barrel and makes it easy <strong>to</strong><br />

replace scratched or broken glass. A stainless steel<br />

thumb screw holds syringes firmly in place.<br />

Pro-Tec® II Syringe Shields:<br />

Syringe Shield, 5 ml 007-900<br />

Syringe Shield, 10 ml 007-909<br />

Syringe Shield 20 ml 007-917<br />

Replacement Glass for Pro-Tec® II Syringe Shields:<br />

Syringe Shield Replacement Glass, 5 ml 127-789<br />

Syringe Shield Replacement Glass, 10 ml 127-999<br />

6 sales@bartec<strong>technologies</strong>.com<br />

Version 2.0<br />

Syringe Shield, 5 cc<br />

Syringe Shield 20 cc


Vial Shields<br />

Tungsten Vial Shield Colour Coded Vial Shields<br />

• Virtually unbreakable<br />

• Safe handling of radioactive liquids<br />

The Tungsten Vial Shield is designed <strong>to</strong> greatly reduce<br />

exposure <strong>to</strong> vials containing liquid radioiso<strong>to</strong>pes. The<br />

shield is constructed of .19" (.48 cm) thick tungsten,<br />

equivalent <strong>to</strong> .38" (1 cm) lead at 150 keV.<br />

Vials can be loaded from the <strong>to</strong>p or bot<strong>to</strong>m of the shield.<br />

A loss-proof slide injection port on the <strong>to</strong>p allows easy<br />

access <strong>to</strong> the vial septum.<br />

The <strong>to</strong>ugh tungsten will retain its shape under the<br />

roughest handling and is virtually unbreakable.<br />

Specifications<br />

Dimensions: 3.7 x 7 cm<br />

Inside Diameter: 2.5 cm<br />

Lead Equivalency: .1 cm<br />

Vial Shield, Tungsten, .38" lead equiv 053-805<br />

Colour coding is the easiest way <strong>to</strong> avoid a mix up.<br />

These vial shield colours match the C.I.S. kits and are<br />

compatible with most radiopharmaceutical vials. The<br />

body of the vial is constructed of .31" thick lead covered<br />

with a coloured acrylic collar.<br />

A 4.2 density lead glass window provides protection<br />

and visibility.<br />

Vials can be loaded from the <strong>to</strong>p or bot<strong>to</strong>m of the shield.<br />

The <strong>to</strong>p features an attached sliding lid for easy access<br />

<strong>to</strong> the vial septum.<br />

Specifications<br />

Dimensions: 4.3 x 7.8 cm<br />

I.D.: 2.7 cm<br />

Lead Shielding: .0.8 cm<br />

Weight: 0.9 kg<br />

Color-Coded Vial Shields without glass:<br />

Vial Shield, (Glucoscan), Red 053-601<br />

Vial Shield, (Osteolite,) Purple 053-602<br />

Vial Shield, (Pulmolite), Light orange 053-603<br />

Vial Shield, (Pyrolite), Blue 053-604<br />

Vial Shield, (Hepa<strong>to</strong>lite), Brown 053-605<br />

Vial Shield, (Microlite), Yellow 053-606<br />

Colour-Coded Vial Shields with glass:<br />

Vial Shield, (Glucoscan), Red 053-701<br />

Vial Shield, (Osteolite), Purple 053-702<br />

Vial Shield, (Pulmolite), Light orange 053-703<br />

Vial Shield, (Pyrolite), Blue 053-704<br />

Vial Shield, (Hepa<strong>to</strong>lite), Brown 053-705<br />

Vial Shield, (Microlite), Yellow 053-706<br />

+44 (0) 1276 20842<br />

Version 2.0<br />

7


Table Top Shields<br />

Standard Table Top Shield Mini Table Top Shield<br />

• Constructed of lead and lead glass<br />

• Integral stainless steel tray with spill proof lip<br />

• Optional bot<strong>to</strong>m and side shields available<br />

Specifications<br />

Table Top Shields<br />

Lead Shielding: 0.64 cm thick<br />

Dimensions: See drawings featured.<br />

Viewing Panel: 2.0 mm or 4.0 mm lead glass window<br />

Side Shields<br />

Lead Shielding: 0.64 cm thick<br />

Table<strong>to</strong>p Shields:<br />

Shield, Table Top, Standard, .5" lead 042-216<br />

With 2.0 mm lead glass<br />

Table<strong>to</strong>p Shield Lead Glass Panels:<br />

Lead Glass Panels can be paired <strong>to</strong> achieve 4.0 mm lead<br />

equivalency.<br />

Lead Glass Plate, 2.0 mm, Standard 017-121<br />

Side Shield, Standard, .25" lead 042-220<br />

Bot<strong>to</strong>m Shield, Standard, .125" lead 042-218<br />

• Constructed of lead and lead glass<br />

• Integral stainless steel tray with spill proof lip<br />

• Optional bot<strong>to</strong>m and side shields available<br />

Specifications<br />

Table Top Shields<br />

Lead Shielding: 0.64 cm thick<br />

Viewing Panel: 2.0 mm or 4.0 mm lead glass window<br />

Shield, Table Top, Mini, .5" lead 042-016<br />

With 2.0 mm lead glass<br />

Lead Glass Plate, 2.0 mm, Mini 017-810<br />

Side Shield, Mini, .25" lead 042-221<br />

Bot<strong>to</strong>m Shield, Mini, .125" lead 042-018<br />

8 sales@bartec<strong>technologies</strong>.com<br />

Version 2.0


Hazard Tape<br />

Hazard tape is a highly visible Magenta and Yellow<br />

warning tape that’s perfect for identifying physical<br />

hazard areas. Constructed of 6ml vinyl, the tape is durable<br />

<strong>to</strong> withstand long term placement.<br />

The tape will adhere <strong>to</strong> any clean smooth surface.<br />

Tape, Hazard 026-020<br />

Warning Rope<br />

• Brightly coloured—magenta and yellow<br />

• Triple– strand strength<br />

Made of high quality polypropylene, this triple strand<br />

rope assues high visibility and strength.<br />

Rope, Warning (price per foot) 121-072<br />

Diameter 0.8 cm<br />

Minimum order is 100’.<br />

Hazard Warnings<br />

Version 2.0<br />

Metal Signs<br />

Metal signs finished in heavy-duty baked enamel on<br />

30-gauge steel with holes for convenient attachment <strong>to</strong><br />

inner or outer doors.<br />

Caution radioactive materials 024-999<br />

Caution radiation Area 024-900<br />

Shipping Labels<br />

Pressure sensitive with peel off backing.<br />

Comply with fed eral Regulations, Title 49-<br />

Transportation of Hazard ous Materials Regulations,<br />

Dept. of Transportation, 49CFT, Part 173 as <strong>to</strong> wording,<br />

symbols.<br />

Label, Radioactive 1 white 20/pkg 030-001<br />

Label, Radioactive 2 Yellow 20/pkg 030-002<br />

Label, Radioactive 3 Yellow 20/pkg 030-003<br />

+44 (0) 1276 20842<br />

9


Features<br />

10<br />

Personal Dosimeter DKG-21<br />

Stand-alone use or use within the au<strong>to</strong>mated PC based system for personal<br />

dosimetry control.<br />

Dose accumulation his<strong>to</strong>ry s<strong>to</strong>rage in the non volatile memory with reference<br />

<strong>to</strong> real time.<br />

Dose accumulation his<strong>to</strong>ry transfer <strong>to</strong> a PC computer through the integrated<br />

infrared port.<br />

Power down prevention mode until all accumulated data has been read<br />

from the dosimeter.<br />

Gamma radiation EDR and ED threshold levels programming using on-line<br />

<strong>to</strong> a computer, control keys, or<br />

manually.<br />

The blocking of certain indication modes using computer<br />

commands on line.<br />

Light and audio alarm of exceeded programmed threshold level of gamma<br />

radiation EDR and ED.<br />

Au<strong>to</strong>matic digital display switch off if current gamma background<br />

is lower than the preset threshold level and<br />

Instant switch on when:<br />

- any control key pressed;<br />

- the gamma background increases above the preset threshold level;<br />

- when the alarm clock rings.<br />

Periodic self testing (batteries, detec<strong>to</strong>r).<br />

Energy compensated Geiger-Muller counter.<br />

Radiation Moni<strong>to</strong>rs<br />

Version 2.0<br />

Features<br />

Radiation Moni<strong>to</strong>r Terra<br />

Five independent measuring channels with alternate<br />

indication of data on the single liquid crystal display.<br />

Built-in gamma, beta sensitive Geiger-Muller counter.<br />

Prompt evaluation of gamma background within 10<br />

seconds.<br />

Au<strong>to</strong>matic subtraction of gamma background at<br />

measurement of beta contamination.<br />

Measurement results averaging, manually and<br />

au<strong>to</strong>matically.<br />

Au<strong>to</strong>matic setting of measurement intervals and ranges.<br />

Audio indication of each detected gamma-quantum and beta-particle<br />

(with switch off option).<br />

Two-<strong>to</strong>ne audio alarm of exceeded programmed<br />

threshold levels.<br />

Digital display backlight.<br />

Two AAA size batteries.<br />

Power supply discharge indication.<br />

Shock resistant frame.<br />

Small weight and dimension parameters.<br />

Measurement ranges and basic relative errors:<br />

Gamma and X-ray radiation<br />

equivalent dose rate (<br />

Measurement ranges and basic relative errors:<br />

Personal gamma radiation equivalent dose<br />

rate HP(10)<br />

Personal gamma radiation<br />

equivalent dose HP(10)<br />

Energy range of detected gamma and X-ray<br />

radiation and energy dependence<br />

µSv/h<br />

mSv<br />

MeV<br />

0.1…1 000 000;<br />

±15%<br />

0.001…9 999;<br />

±15%<br />

0.05…6.0;<br />

(0.05…1.25; ±25%)<br />

Recording resolution of dose<br />

minutes 5…255<br />

accumulation his<strong>to</strong>ry in the non volatile<br />

memory<br />

Time of data s<strong>to</strong>rage in the non volatile years not less than 10<br />

memory<br />

Data exchange rate through infrared port bit/s 38 400<br />

Positive data exchange distance between m not more than 0.3<br />

the dosimeter and infrared port adapter<br />

Lithium battery (CR2450) life<br />

Operating temperature range<br />

Weight<br />

Dimensions<br />

hours<br />

°C<br />

kg<br />

mm<br />

2 200<br />

-10…+50<br />

0.08<br />

86×54×9<br />

137 µSv/h 0.1…9 999;<br />

Cs):<br />

±15%<br />

Gamma and X-ray radiation<br />

equivalent dose ( 137 mSv 0.001…9 999;<br />

Cs):<br />

±15%<br />

Beta-particles flux density<br />

( 90 Sr+ 90 1/(cm²·min) 10…100 000;<br />

Y):<br />

±20%<br />

Equivalent dose accumulation time 1 min … 100 h;<br />

and accuracy of<br />

±0.1 s per 24 h<br />

measurement:<br />

Energy ranges of measurement and energy dependence:<br />

Gamma and X-ray radiation MeV 0.05…3.0;<br />

±25%<br />

Beta radiation MeV 0.5…3.0;<br />

Threshold level programming resolution<br />

for:<br />

µSv/h<br />

0.01<br />

- dose rate<br />

mSv<br />

0.01<br />

- dose<br />

10³/cm²·min 0.01<br />

- flux density<br />

Measurement time intervals<br />

Battery life<br />

Operating temperature range<br />

Weight<br />

Dimensions<br />

seconds<br />

hours<br />

°C<br />

kg<br />

mm<br />

1…70<br />

2 000<br />

-20…+50<br />

0.15<br />

120×52×26<br />

sales@bartec<strong>technologies</strong>.com


Radiation Moni<strong>to</strong>rs<br />

Thermo Scientific Mini 900 Survey Moni<strong>to</strong>r<br />

The Mini-moni<strong>to</strong>r serves as a portable or bench <strong>to</strong>p style radiation counter available with a variety of different<br />

probes <strong>to</strong> accommodate radiation detection needs. <strong>Bartec</strong> offer this product with the Type 44A Scintillation<br />

Probe for accurate detection of Tc-99m contamination in Veterinary Practices and Hospitals. The unit is packaged<br />

in durable, lightweight aluminium case, powered either from it’s internal battery pack or from mains power. The unit<br />

contains an internal constant current charger for its rechargeable batteries. Radiation Measurement read-out is on<br />

a large easy <strong>to</strong> <strong>view</strong> logarithmically scaled meter. An alarm can be set <strong>to</strong> trigger at any User selected level on the<br />

scale.<br />

Specifications:<br />

Weight: 1 kg (2.2 lbs)<br />

Size: 180 x 110 x 165 mm (7” x 4.5” x 6.5”)<br />

Batteries: 6 type AA cells, alkaline (IEC LR6) or rechargeable (IEC KR 15/51)<br />

Battery Life: Approximately 300 hours at 4hours/day<br />

Paralysis Time: Scale corrected <strong>to</strong> give true reading<br />

Meter Integration Time: 1 <strong>to</strong> 4 seconds set <strong>to</strong> match counting rate<br />

Radiation detec<strong>to</strong>r: Type 44A Sodium iodide crystal (32 mm dia. by 2.5 mm thick) mounted on the front<br />

surface of the probe <strong>to</strong> facilitate moni<strong>to</strong>ring of large contaminated areas. Suitable for a<br />

range of energies from approximately 15 keV <strong>to</strong> 250 keV. It is also beta sensitive for<br />

energies above 500 keV. Diameter 50 mm Length 180 mm. Aluminum window weight<br />

14 mg cm -2 .<br />

Radiation Detected: Gamma and X-Rays only<br />

Overload Protection: No meter “fallback” with intensities at least 100 times full scale reading<br />

Main Power: 12-18 VDC from mains converter unit<br />

+44 (0) 1276 20842<br />

Version 2.0<br />

11


Designed for facilities receiving unit<br />

doses<br />

Features at a glance:<br />

• Large, easy <strong>to</strong> read backlit LCD<br />

• Au<strong>to</strong>matic range selection; ranges up <strong>to</strong> 40 curies of<br />

Tc-99m<br />

• Pre-programmed for 88 most commonly used<br />

radionuclides<br />

• Displays in curies or becquerels<br />

• Small footprint for an economic workspace<br />

• Ultra-fast response<br />

• Self Diagnostic Software<br />

• Remote Ionisation Chamber<br />

• RS-232 bi-directional serial communications port<br />

Dose Calibra<strong>to</strong>r<br />

The RS-232 port enables the A<strong>to</strong>mlab 400 Dose Calibra<strong>to</strong>r <strong>to</strong><br />

communicate with most commercially available nuclear medicine<br />

management systems.<br />

The A<strong>to</strong>mlab 400 provides fast, accurate radionuclide activity<br />

measurements with performance that easily complies with the most<br />

stringent regula<strong>to</strong>ry requirements. The unit is simple <strong>to</strong> operate.<br />

There is a routine list of ten pre-programmed iso<strong>to</strong>pes plus another<br />

seven that can be user defined. Any four iso<strong>to</strong>pes will be displayed<br />

at a time. The A<strong>to</strong>mlab 400 display can be mounted on a wall or<br />

placed on a desk<strong>to</strong>p. In addition, there is a library containing 88<br />

iso<strong>to</strong>pes listed alphabetically, including Y-90 and Sr-89. Activity is<br />

displayed on an LCD panel in either Curie or Becquerel units.<br />

Background correction is performed at the <strong>to</strong>uch of a but<strong>to</strong>n. Range<br />

selection is au<strong>to</strong>matic. Activity measurements are performed by a<br />

microprocessor-controlled electrometer located within the detec<strong>to</strong>r<br />

assembly of the ionisation chamber. The chamber is shielded<br />

with .25" (6.3 mm) lead. It can be located up <strong>to</strong> eight feet away from<br />

the display unit. Chamber bias is generated within the display unit<br />

by an electronic high voltage supply, eliminating the need for<br />

Dose Calibra<strong>to</strong>r, A<strong>to</strong>mlab 400 , 230V 086-335<br />

Includes Vial/Syringe Dipper and Well Insert<br />

Optional Items<br />

086-423 Moly Shield, Vial 0.3” lead<br />

086-435 Moly Shield, Syringe 0.3” lead<br />

086-509 Linea<strong>to</strong>r<br />

086-242 Vial/Syringe Dipper<br />

086-241 Well Insert<br />

12<br />

A<strong>to</strong>mlab 400 Dose Calibra<strong>to</strong>r<br />

sales@bartec<strong>technologies</strong>.com<br />

Version 2.0<br />

SPECIFICATIONS<br />

Iso<strong>to</strong>pe Selection Keys: Ten pre-programmed – Tc-99m,<br />

Co-57, Cs-137, I-131, In-111, Ga-67, Xe-133, I-123, Tl-201,<br />

and Mo-99; seven additional keys for user-set iso<strong>to</strong>pes; two<br />

new iso<strong>to</strong>pe keys and a full alphabetical list of 88 iso<strong>to</strong>pes<br />

Activity Range: 0.1 µCi <strong>to</strong> 40Ci (.001 mBq <strong>to</strong> 1500 GBq) of<br />

Tc-99m<br />

Energy Range: 25 keV <strong>to</strong> 3 MeV pho<strong>to</strong>ns<br />

Response Time: One <strong>to</strong> two seconds for doses greater than<br />

200 uCi; three seconds for doses greater than 20 uCi; 50-100<br />

seconds below 20 uCi of Tc-99m with default threshold,<br />

threshold adjustable <strong>to</strong> reduce counting time<br />

Detec<strong>to</strong>r Linearity: ±1% or 0.2 µCi, whichever is greater<br />

Electrometer Linearity: ±1% or 0.2 µCi, whichever is greater<br />

Electrometer Accuracy: ±1% or 0.2 µCi, whichever is greater<br />

Overall Accuracy: ±3% or 0.3 µCi, whichever is greater; overall<br />

accuracy is affected by such fac<strong>to</strong>rs as the accuracy of the<br />

specific source calibration, geometric variations due <strong>to</strong> sample<br />

volume or configuration, detec<strong>to</strong>r linearity, electrometer<br />

accuracy and readout accuracy<br />

Repeatability: ±0.3% above 1 mCi short term (24 hr); 1% long<br />

term (one yr); exclusive of background<br />

Digital Calibration Dial: Four-digit LED dial display with<br />

increment/decrement keys <strong>to</strong> change the value; range is from<br />

0.0 <strong>to</strong> 999.9<br />

Detec<strong>to</strong>r: Well-type pressurized ionization chamber, with<br />

Argon fill gas; well opening 2.75" (7 cm), well depth 10.25" (26<br />

cm)<br />

Chamber Gas Pressure: 149KPa gauge (21.6 psig) at 20<br />

degrees C or 250KPa absolute (36.3 psia) at 20 degrees<br />

C. IATA regulation 3.2.2.4 Exempts Gases of Division 2.2<br />

from Dangerous Goods Regulations when transported at<br />

pressure less than 200KPa gauge (29 psig) at 20 degrees<br />

C. Device is shipped standard goods.<br />

Detec<strong>to</strong>r Shielding: .25" (6.3 mm) lead on all sides except <strong>to</strong>p<br />

well opening; supplementary shielding available<br />

Chamber Bias: 355 ± 5 volts<br />

Environmental Operating Conditions:<br />

Temperature: 0-40° C<br />

Humidity: 0-90% rh, non-condensing<br />

Power Requirements: 100 <strong>to</strong> 240 VAC, 0.6 – 0.3 amps, au<strong>to</strong><br />

switching; APS Power Supply (APS22ES-150160), for medical<br />

use<br />

Line Frequency: 50/60 Hz; detachable line cord; built-in EMI<br />

filter and transient suppression<br />

Detec<strong>to</strong>r and Interface Cables: 8' (243 cm) long, six<br />

conduc<strong>to</strong>r cables (two carry power, two for chassis ground, two<br />

carry serial data for digital I/O)<br />

Display Unit:<br />

Dimensions: 6.75" w x 6" depth x 5" h (17.1 x 15.3 x 12.7 cm)<br />

Weight: 3.6 lb (1.64 kg); desk<strong>to</strong>p or wall mountable<br />

Detec<strong>to</strong>r Unit:<br />

Dimensions: 6" dia x 15.5" h (15.24 x 39.37 cm)<br />

Well I.D.: 2.75" dia x 10.5" h (7 x 26.7 cm)<br />

Well I.D. with Liner: 2.5" dia x 10.25" h (6.35 x 26 cm)<br />

Lead Shielding: .25" thick (6.3 mm)<br />

Weight: 35 lb (16 kg)


Radiacwash<br />

Radiacwash has been in use since 1951 it is the most<br />

popular general-purpose decontamination solution<br />

specifically created for the fast and safe removal of<br />

liquid radioactive contaminants. Firstly, it sequesters<br />

metallic ions, which contaminate surfaces. Secondly, it<br />

lifts up and firmly suspends contaminating particles.<br />

Allowing contamination <strong>to</strong> be absorbed and then<br />

rinsed away with water.<br />

Radicawash, Spray Mist, 1 L bottle 005-400<br />

Radiacwash, Bottle 1 gal* 005-100<br />

Radiacwash, carboy w/spigot, 5 gal* 005-105<br />

Radiacwash, drum, 55 gal* 005-155<br />

*US gallon<br />

Radiacwash Towelettes<br />

Radiacwash Towelettes are the most efficient and safest<br />

way <strong>to</strong> remove radioactive contamination from hands<br />

and small objects. Simply remove the <strong>to</strong>welette from the<br />

foli packet, scrub hands thoroughly and wash the contamination<br />

away with running water.<br />

Radicawash, Towelettes 100/box 005-300<br />

Decontamination<br />

+44 (0) 1276 20842 13<br />

Version 2.0<br />

Decontamination kit<br />

The A<strong>to</strong>mlab Decontamination Kit contains all the<br />

equipment needed <strong>to</strong> cope with a radioactive spill or<br />

routine decontamination problem in the labora<strong>to</strong>ry.<br />

The drum serves as a container for the kit components<br />

and as waste transfer/s<strong>to</strong>rage vessel.<br />

Contents of Kit<br />

Quantity Cat No Item<br />

1 - 30 gallon fibre drum<br />

2 prs 118-125 Large coverall<br />

2 prs 119-200 Shoe covers<br />

2 120-530 Respira<strong>to</strong>rs<br />

4 120-750 Filters<br />

2 prs 034-005 Gloves<br />

1 gal 005-100 Radiacwash<br />

1 box 005-300 Radiacwash Towelettes<br />

1 bottle 005-400 Radiacwash spray Mist, 1 Litre<br />

10 040-108 Poly Bags<br />

1 001-012 12” Nip<strong>to</strong>ng<br />

1 ea Sponge, mop,scrub brush, pail,<br />

rope,assorted signs<br />

Decontamination Kit 121-180


<strong>Bartec</strong> Technologies Limited, Unit 8, Stanhope Gate, Stanhope Road, Camberley, Surrey, GU15 3DW, UK.<br />

Tel: 01276 20842 • Fax: 01276 20891 • sales@bartec<strong>technologies</strong>.com • www.bartec<strong>technologies</strong>.com<br />

<strong>Bartec</strong> Technologies Ltd, Avenue des Mouettes 14, Bruxelles 1150, Belgium.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!