DOOSAN STEAM GENERATORS<br />

Tonghae 2 x 200 MWe Power Plant Project /by DOOSAN(*)<br />

Client Korea Electric Power Co.(KEPCO), Korea<br />

Location Tonghae, Korea<br />

Type 2 x 200 MWe CFB Boiler<br />

Main <strong>Steam</strong> Flow @ BMCR 694 tons/hr<br />

Superheater Outlet Pressure 176 kg/cm 2 g<br />

Superheater Outlet Temperature 541 °C / 1,006 °F<br />

Reheater Outlet Temperature 541 °C / 1,006 °F<br />

Yosu 1 x 340 MWe CFB Power Plant Project /by DOOSAN(**)<br />

Client KOSEP, Korea<br />

Location Yosu, Korea<br />

Type 1 x 340 MWe CFB Boiler<br />

Main <strong>Steam</strong> Flow @ BMCR 1,025 tons/hr<br />

Superheater Outlet Pressure 171.5 kg/cm 2 g<br />

Superheater Outlet Temperature 541 °C / 1,006 °F<br />

Reheater Outlet Temperature 541 °C / 1,006 °F<br />

Tonghae 2 x 200 MWe, Korea<br />

* Licensed by ALSTOM<br />

**Licensed by Foster Wheeler