17.01.2013 Views

Slip Ring Assemblies Program 5100 - Conductix-Wampfler

Slip Ring Assemblies Program 5100 - Conductix-Wampfler

Slip Ring Assemblies Program 5100 - Conductix-Wampfler

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

24<br />

Combination of <strong>Slip</strong> <strong>Ring</strong> <strong>Assemblies</strong><br />

Enclosed <strong>Slip</strong> <strong>Ring</strong> Assembly e.g. Type GS19 /13 /18<br />

Electrical data<br />

• Voltage:<br />

- max. 1000/630 V~= (690V) 1)<br />

- according to DIN VDE 0110<br />

- overtension category III<br />

- insulating material group II / III<br />

- degree of contamination 3<br />

• <strong>Ring</strong> construction:<br />

150 A + PE / 50 A / 25 A<br />

• Protection class: IP 54<br />

(higher protection class on request)<br />

Drive arm<br />

~ 62<br />

ø 16<br />

ø 300<br />

ø 60<br />

M63x1,5<br />

125<br />

16<br />

21<br />

h<br />

110<br />

ø 320<br />

Holes in the bottom plate:<br />

1x for cable gland M50x1.5<br />

1x for cable gland M25x1.5<br />

1x for cable gland M25x1.5<br />

ø 17<br />

ø 140<br />

ø 175<br />

Mounting fl ange<br />

H<br />

Additional technical specifi cations<br />

• Rotational speed for<br />

- standard type (MS-rings and<br />

Br-brushes): 1-100 min -1<br />

- data (ML-rings and Ag-brushes):<br />

1-30 min -1<br />

• Bearing: anti-friction bearing (sealedfor-lifetime)<br />

• Cable connection:<br />

- Main current rings with strand<br />

wiring on request<br />

- control rings on terminal board<br />

• Protective cover:<br />

- removable vertical-up<br />

- available on request with divided<br />

cover (removable to the side) and/or<br />

side access window<br />

• Corrosion protection:<br />

- steel parts galvanized and/or<br />

powder coated<br />

- stainless steel enclosure on request<br />

• Ambient temperature:<br />

- from -35°C up to max. +50°C<br />

- at > 30°C the max. current load<br />

has to be reduced accordingly<br />

- higher temperatures possible on<br />

request<br />

• Position of installation: vertical<br />

(other positions on request)<br />

Components included<br />

• Standard without glands<br />

• Cable glands on request<br />

Options<br />

• Heater<br />

• Rotary transmission for gases and<br />

liquids (protection class IP 40, higher<br />

protection class on request)<br />

1) The voltages apply for slip ring assemblies,<br />

installed in systems (parts of systems)<br />

that are not directly fed by the low-voltage<br />

net (VDE 0110-1/2008-01: 4.3.2.2.2,<br />

table F.4).<br />

On systems (part of systems) with direct<br />

feeding from the low-voltage net, the<br />

values in brackets are permissible for<br />

alternating current (VDE 0110-1/2008-01:<br />

4.3.2.2.1, table F.3b).<br />

Please contact us with your<br />

specifi c requirements and<br />

we would be happy to design<br />

a customized solution<br />

for your application.