Combination of <strong>Slip</strong> <strong>Ring</strong> <strong>Assemblies</strong><br />
Enclosed <strong>Slip</strong> <strong>Ring</strong> Assembly e.g. Type GS19 /13 /18<br />
Electrical data<br />
• Voltage:<br />
- max. 1000/630 V~= (690V) 1)<br />
- according to DIN VDE 0110<br />
- overtension category III<br />
- insulating material group II / III<br />
- degree of contamination 3<br />
• <strong>Ring</strong> construction:<br />
150 A + PE / 50 A / 25 A<br />
• Protection class: IP 54<br />
(higher protection class on request)<br />
Drive arm<br />
~ 62<br />
ø 16<br />
ø 300<br />
ø 60<br />
M63x1,5<br />
125<br />
16<br />
21<br />
h<br />
110<br />
ø 320<br />
Holes in the bottom plate:<br />
1x for cable gland M50x1.5<br />
1x for cable gland M25x1.5<br />
1x for cable gland M25x1.5<br />
ø 17<br />
ø 140<br />
ø 175<br />
Mounting fl ange<br />
H<br />
Additional technical specifi cations<br />
• Rotational speed for<br />
- standard type (MS-rings and<br />
Br-brushes): 1-100 min -1<br />
- data (ML-rings and Ag-brushes):<br />
1-30 min -1<br />
• Bearing: anti-friction bearing (sealedfor-lifetime)<br />
• Cable connection:<br />
- Main current rings with strand<br />
wiring on request<br />
- control rings on terminal board<br />
• Protective cover:<br />
- removable vertical-up<br />
- available on request with divided<br />
cover (removable to the side) and/or<br />
side access window<br />
• Corrosion protection:<br />
- steel parts galvanized and/or<br />
powder coated<br />
- stainless steel enclosure on request<br />
• Ambient temperature:<br />
- from -35°C up to max. +50°C<br />
- at > 30°C the max. current load<br />
has to be reduced accordingly<br />
- higher temperatures possible on<br />
request<br />
• Position of installation: vertical<br />
(other positions on request)<br />
Components included<br />
• Standard without glands<br />
• Cable glands on request<br />
Options<br />
• Heater<br />
• Rotary transmission for gases and<br />
liquids (protection class IP 40, higher<br />
protection class on request)<br />
1) The voltages apply for slip ring assemblies,<br />
installed in systems (parts of systems)<br />
that are not directly fed by the low-voltage<br />
net (VDE 0110-1/2008-01: 4.3.2.2.2,<br />
table F.4).<br />
On systems (part of systems) with direct<br />
feeding from the low-voltage net, the<br />
values in brackets are permissible for<br />
alternating current (VDE 0110-1/2008-01:<br />
4.3.2.2.1, table F.3b).<br />
Please contact us with your<br />
specifi c requirements and<br />
we would be happy to design<br />
a customized solution<br />
for your application.