18.01.2013 Views

Elite Etch CU Decapsulator for Copper Data Sheet

Elite Etch CU Decapsulator for Copper Data Sheet

Elite Etch CU Decapsulator for Copper Data Sheet

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Dimensions -<br />

Weight -<br />

Power Source<br />

Acid temp. range<br />

Acid temp. set point<br />

<strong>Etch</strong> cavity (up to)<br />

choice of acid<br />

acid mix ratios<br />

rinse options<br />

etch times -<br />

etch modalities -<br />

temperature ranges -<br />

volume selection<br />

program storage -<br />

ambient temperature range<br />

ambient humidity<br />

tubing that can be fed from either side of the Bottle Box.<br />

The Bottle Box Assembly and the etcher unit both contain a<br />

fluid sensor to alert the operator in the event of a gross acid<br />

leak from any of the bottles or internal httings. Bottle<br />

exchange on any decapsulator holds possible risk to the<br />

operator. We have incorporated a universal pivoting<br />

interconnect that allows simple and trouble free bottle<br />

exchange with minimal exposure to residual acid.<br />

SPECIFICATIONS<br />

<strong>Decapsulator</strong> 7 .5 x 12.5 x 12 inch ( I 90 x 3 1 8 x 305 mm )<br />

Bottle Assembly 10 x 5 x 11 inch (254 x127 x279 mm<br />

approx. 35 lbs.(16 Kg)<br />

90 -130 or 230-250 VAC 49 to 61Hz<br />

10 to 250 degrees C. totally independent of ambient temperature<br />

1.0 C + 1% of setting. Independent of ambient temperature.<br />

2l x7l mm (30 mm max diagonal)<br />

fuming sulfuric acid, fuming nitric acids, mixed acids<br />

(nitriclo sulfuric ratios) 9:1, 6:1, 5:1, 4:1,'7:2,3'.1, 5;2,2:1,3:2, L:l ,l'.2, l:3, L:4, 1:5<br />

fuming sulfuric acid fuming nitric acid mixed acids no rinse<br />

I to2,400 seconds (1 sec. increments)<br />

dynamic (real time) adjustment of etch time<br />

Pulse <strong>Etch</strong>, Reciprocal <strong>Etch</strong> Acid Pulse (REAP)<br />

NOTE: REAP is a superior approach to maximizing the carrying capacity <strong>for</strong> the etch<br />

acid(s) within the package volume. It allows<br />

superior etch characteristics when nitric acid or mixed acids are selected.<br />

2O-90"C (nitric acid)2A-25A'C (sulturic acid) 10-100"C (mixed acids)<br />

2 to 6 ml. per minute <strong>for</strong> all acids and acid mixes at a temperature above i00"C' 2 to 8<br />

ml per minute nitric or mixed below 100'C.<br />

100 programs stored to nonvolatile memory<br />

15 to 26 degees C<br />

0 to 70o/o non-condensing<br />

ISIf,IN;:.:lil$lIl<br />

RKD Engineering, Corp.<br />

316 South Navarra Drive<br />

Scotts Valley, CA 95066-3622<br />

TEL: 831-430-9464 FAX: 831-438-0485<br />

Your local representative is:<br />

ViaTec Sales 3 Norway Rd Milton, MA 02186<br />

Tel: (617)7174906 Email: info@viatecsales.com<br />

www.viatecsales.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!