20.01.2013 Views

LSI Greenlee?? RDB/RDS Series - LSI Industries Inc.

LSI Greenlee?? RDB/RDS Series - LSI Industries Inc.

LSI Greenlee?? RDB/RDS Series - LSI Industries Inc.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Lighting Designer-Kennedy/Reeder, Photographer-Vance Roth<br />

Lighting Designer-Ross DeAlessi, Photographer-James F.Wilson<br />

Lighting Designer-Schuler & Shook, Photographer-Mark Ballog Copyright 1999


<strong>RDB</strong><br />

<strong>RDB</strong>-<strong>RDS</strong><br />

S e r i e s<br />

SIMPLY THE BEST!<br />

<strong>RDS</strong><br />

<strong>RDB</strong> and <strong>RDS</strong> <strong>Series</strong> luminaires from <strong>LSI</strong><br />

<strong>Greenlee</strong> Lighting are without equal. No other<br />

inground product offers the performance,<br />

strength, and capabilities that make <strong>RDB</strong> and<br />

<strong>RDS</strong> <strong>Series</strong> luminaires the industry standard.<br />

<strong>RDS</strong> LUMINAIRES OFFER<br />

• RTL Technology<br />

Reduced Temperature Lens<br />

Variable Optics<br />

SPV – 15°-90° beam<br />

FLV – 36°-110° beam<br />

Drive-Over Capability<br />

<strong>RDB</strong> LUMINAIRES OFFER<br />

RTL Technology<br />

Reduced Temperature Lens<br />

SWW – Superior Wall Wash and Sign<br />

Lighting Optics<br />

Variable Optics<br />

SPV – 10°-45° beam<br />

FLV – 30°-80° beam<br />

Drive-Over Capability


<strong>RDB</strong> AND <strong>RDS</strong> SERIES UPLIGHTS: AN INNOVATIVE FAMILY<br />

Reduced Temperature Lens (RTL) Technology - Another Innovation<br />

RTL Technology is the latest example of the Leadership, Strength, and Innovation that you have come to<br />

expect from <strong>LSI</strong> <strong>Greenlee</strong> Lighting.<br />

In response to concerns about lens temperatures, <strong>Greenlee</strong> researched standards and technology on a<br />

global basis to develop its RTL system, which significantly reduces lens temperatures, allowing its<br />

luminaires to meet stringent international standards.<br />

Dramatically reduces lens surface temperature<br />

Filters infrared energy – prevents IR rays from heating the lens<br />

Only visible energy passes through the RTL filter to the lens<br />

Available for <strong>RDB</strong>, <strong>RDS</strong>, and CDB <strong>Series</strong> luminaires<br />

Temperature Comparison<br />

Without RTL<br />

With RTL<br />

<strong>RDS</strong><br />

70MH<br />

FLV<br />

Without RTL<br />

With RTL<br />

<strong>RDS</strong><br />

70MH<br />

SPV<br />

Without RTL<br />

With RTL<br />

<strong>RDB</strong><br />

100MH<br />

SPV<br />

<strong>LSI</strong> <strong>Greenlee</strong> Lighting didn’t stop working after it developed<br />

RTL Reduced Temperature Lenses and its new SWW optics;<br />

we stayed in the engineering lab and created several additional<br />

exciting improvements.<br />

LIG – Low Iron Glass<br />

Standard lenses are now available in a<br />

new low–iron formulation for color<br />

critical projects<br />

Perfect for high CRI lamps<br />

Adds no color to the beam<br />

Eliminates blue-green tint<br />

Two sizes – <strong>RDB</strong> and <strong>RDS</strong><br />

SRL – Slip Resistant Lens<br />

Inground fixtures have been used safely<br />

for years, but an end-user’s increased<br />

concern about liability led us to develop<br />

SRL lenses<br />

Improved Slip Resistance<br />

Etched prior to tempering<br />

Open pattern allows runoff<br />

Two sizes – <strong>RDB</strong> and <strong>RDS</strong><br />

JUST SAY NO<br />

T O H OT F E E T<br />

Specify RTL<br />

Technology<br />

for Pedestrian<br />

Friendly<br />

Products.<br />

Lighting Industry Recognition:<br />

The Progress Committee of the Illuminating Engineering<br />

Society of North America recognized RTL Reduced<br />

Temperature Lens technology from <strong>LSI</strong> <strong>Greenlee</strong> Lighting<br />

“as a unique and significant advancement in the art and<br />

science of lighting”. We believe that specifiers, owners, and<br />

end-users will find the benefits of RTL impressive, too.


In Concrete<br />

Concrete<br />

Install fixture<br />

flush with concrete,<br />

marble, or pavers<br />

In Soil<br />

Install fixture slightly<br />

above grade<br />

Back fill hole<br />

w/ sand or gravel<br />

Use thread sealant<br />

to prevent leakage<br />

Rigid PVC Conduit<br />

(by others)<br />

Flexible Conduit<br />

(by others)<br />

Bolt/nuts<br />

(by others)<br />

In Marble/Pavers<br />

Marble or pavers<br />

Trim ring<br />

(optional)<br />

In Low Marshy<br />

Areas<br />

Rebar<br />

(by others)<br />

Pour concrete<br />

to anchor rebar<br />

<strong>RDB</strong>/<strong>RDS</strong> Installation<br />

For easy installation and trouble-free operation, <strong>LSI</strong> <strong>Greenlee</strong> Lighting recommends:<br />

Follow complete installation instructions packaged with each luminaire (also available on our website)<br />

Use flexible PVC conduit and apply thread sealant to all conduit fittings<br />

Connect supply and fixture wires with silicone filled connectors (supplied)<br />

Seal conduit entries (around wires - from inside j-box) using mastic in Seal Pack<br />

Encapsulate conduit entries and wires with potting compound supplied in Seal Pack<br />

Install junction box cover and properly tighten all fasteners<br />

Install Power Pack – PPK, Access Barrier Plate, and Optics as instructed<br />

Clean lens gasket and gasket seating surface (fixture flange)<br />

Install lens, lens retainer (or replacement accessory), and fasteners<br />

Using an alternating torque sequence, tighten fasteners until lens frame seats against housing.<br />

<strong>RDB</strong> Shown<br />

<strong>RDS</strong> Shown<br />

Tie down screwkit<br />

P/N 35750005<br />

1/4"∅ perforated<br />

strap (by others)


EXAMPLE :<br />

TO ORDER FIXTURE: Select appropriate choice from each column as in example below.<br />

<strong>RDB</strong> 175MH 120 FLV IDL<br />

➧<br />

<strong>RDS</strong> Marker<br />

<strong>RDS</strong> Uplight<br />

50MH<br />

➧<br />

26, 32, 42 CFL<br />

35, 50, 70, 100MH<br />

50 1,75 1, 100MV<br />

35, 50, 70, 100 2 HPS<br />

INC Up to 150W<br />

PAR38 lamp or T-10<br />

Halogen Lamp<br />

26, 32,42 CFL<br />

LV<br />

➧<br />

120, 208<br />

240, 277<br />

UE 2<br />

120<br />

208<br />

240<br />

277<br />

120<br />

UE2 LV<br />

➧<br />

DMA – Domed Directional Marker - Aluminum<br />

DMB – Domed Directional Marker - Brass<br />

Optics for Medium Base E-17 Lamps<br />

FLV – Variable Flood 36°– 110°<br />

SPV – Variable Spot 15°– 90°<br />

AWW – Asymmetric Wall Wash Optics<br />

FLF – Fixed Flood Reflector 90°<br />

SPF – Fixed Spot Reflector 15°<br />

Self Reflectorized Lamp Optics<br />

RFL – Up to 100W MH PAR38<br />

Up to 100W MV R30<br />

Or 70W MH PAR30<br />

Optics for T6 CMH lamps with G12 Bi-Pin Base<br />

FLVG12 – Variable Flood 30° – 90° 6<br />

SPVG12 – Variable Spot 18° – 60° 6<br />

RFL – Up to 150W PAR38<br />

or 75W PAR30<br />

AWW-Up to 150W T-10 Halogen<br />

CFF – Compact Fluorescent Flood<br />

MR16S - Single MR16 up to 65 watts<br />

MR16D - Dual MR16's up to 50 watts each<br />

➧<br />

<strong>Series</strong> Wattage/Lamp Type Voltage<br />

Optics Accessories<br />

<strong>RDB</strong> 50 1,70 1,100, 150, 175 MH<br />

50 1,75 1, 100, 175 MV<br />

50, 70, 100, 150 HPS<br />

INC<br />

26, 32,42 FL<br />

120<br />

208<br />

240<br />

277<br />

120<br />

UE 2<br />

Optics for Medium Base E-17 Lamps<br />

FLV – Variable Flood 30°– 80°<br />

SPV – Variable Spot 10°– 45°<br />

AWW – Asymmetric Wall Wash Optics (for E-17<br />

lamps)<br />

FLF – Fixed Flood Reflector 95°<br />

SPF – Fixed Spot Reflector 10°<br />

Optics for T6 CMH Lamps w/G12 bi-pin base<br />

SWW – Superior Wall Wash Optics (for T-6 lamps)<br />

FLVG12 – Variable Flood 30°– 80°<br />

SPVG12 – Variable Spot 10°– 45°<br />

Double Ended Metal Halide Optics<br />

DMH/A – Wall Wash Optics 70, 150<br />

Self Reflectorized Lamp Optics<br />

RFL – Medium Base for Self Reflectorized Lamp<br />

MV 100, 175<br />

PAR38: Med Base PAR38 Lamps<br />

MH 70, 100, 150, 175<br />

PAR38:Medium Base/Up to 250 watt<br />

PAR46:Medium Prong, 200 watt<br />

PAR56: Mogul End Prong, up to 300 watts<br />

AWW– Up to 150 watt T-10 halogen<br />

CFF Compact Flourescent Flood<br />

<strong>RDB</strong>/<strong>RDS</strong> Order Specifications<br />

ALR – Aluminum Lens Retainer–Specify Color 4<br />

BLR – Brass Lens Retainer<br />

CFX – Color Filters 3<br />

DSA – Directional Shield Aluminum–Specify Color 4<br />

DSB – Directional Shield Brass<br />

IDL – Internal Directional Louver 3<br />

INL – Internal Non- Directional Louver (Not avail<br />

with DMH/A, DMH/B and AWW) 3<br />

LL – Less Lamp<br />

LIG – Low Iron Glass Lens<br />

RGA – Rock Guard Aluminum –Specify Color 4<br />

RGB – Rock Guard Brass<br />

RGS – Stainless Steel Rock Guard<br />

RTL – RTL Filter 3<br />

SCE – Side Conduit Entry (two additional,3/4-14 only)<br />

SRL – Slip Resistant Lens<br />

SST– Stainlesss Steel Trim<br />

TDF – Tie Down Fasteners<br />

TR – Tamper Resistant Fasteners – order TR key<br />

separately<br />

<strong>Series</strong> Wattage/Lamp Type Optics Accessories<br />

Voltage<br />

ALR – Aluminum Lens Retainer- Specify Color 4<br />

BLR – Brass Lens Retainer<br />

CFX – Color Filters 3<br />

DSA – Directional Shield Aluminum – Specify Color 4<br />

DSB – Directional Shield Brass<br />

HL – Internal Hexcell Louver 3<br />

LL – Less Lamp<br />

LIG – Low Iron Glass Lens<br />

RGA – Rock Guard Aluminum – Specify Color 4<br />

RGB – Rock Guard Brass 4<br />

RGS – Stainless Steel Rock Guard<br />

SRL – Slip Resistant Lens<br />

RTL – RTL Filter 3<br />

SCE – Side Conduit Entry (two additional,3/4-14 only)<br />

SST – Stainless Steel Trim<br />

TDF – Tie Down Fasteners<br />

TR – Tamper Resistant Fasteners - Order TR Key<br />

Seperately<br />

TR Key – Key for TR Fasteners<br />

Use of RTL, color filters, louvers, or other accessories that block light Lowers Maximum Wattage rating.<br />

Consult page 17 of catalog, website or factory for details.<br />

1. 50 W and 75W MV ballasts are available in 120 V or 277 V only.<br />

2. Universal Electronic 120-277V 50 or 60 HZ Ballast.<br />

3. Restricted use item. Consult page 17 of catalog, website or factory for details.<br />

4.Aluminum Lens Retainer, Rock Guard, and Directional Shield are available with CPP - Clear or BLK- Black Polyester Powder Coat.<br />

5.100 Watt HPS ballast is available in 120 or 277 - volt only.<br />

6 FLVG12 and SPVG12 Optics are designed for use with T-6 Ceramic Metal Halide lamps with G12 bases.Available in 35 and 70 watts only.


OF LUMINAIRES THAT IS LEADING THE INDUSTRY<br />

High Performance Optics – A Traditional <strong>Greenlee</strong> Strength<br />

High-Performance Optics is one of <strong>LSI</strong> <strong>Greenlee</strong>’s strengths. The new reflectors, accessories, and improvements<br />

we’ve developed for the <strong>RDB</strong> and <strong>RDS</strong> increase the capabilities of both family members. SWW optics for the <strong>RDB</strong><br />

solidify our position as the industry leader in reflector design. While significantly improved Spot Optics for the<br />

<strong>RDS</strong> enhances the freedom of choice that has caused designers to specify <strong>RDB</strong> and <strong>RDS</strong> family luminaires on<br />

projects worldwide.<br />

SWW Optics<br />

SWW Optics deliver very uniform light at<br />

incredibly low angles.<br />

They are perfect for illuminating<br />

low walls and signs.<br />

The distribution is wide,<br />

horizontal, and exceptionally<br />

uniform.<br />

At typical setbacks of 3’ – 4’<br />

illumination begins virtually<br />

at grade level.<br />

Scallop effects are practically<br />

eliminated<br />

With extended setbacks, light begins<br />

at significantly lower levels than<br />

competitor’s conventional wall wash optics.<br />

SWW – Superior Wall Wash <strong>RDB</strong><br />

Optics<br />

High CRI T6 Ceramic MH Lamp<br />

Bi-pin base for precise positioning<br />

Smooth, flat, horizontal distribution<br />

Internal Source Shield<br />

Easy relamping<br />

ISS – Internal Source Shield<br />

A product improvement developed for<br />

demanding lighting designers<br />

Two sizes – <strong>RDB</strong> and <strong>RDS</strong><br />

Standard on Spot Optics<br />

Highly tooled – Excellent cutoff<br />

Provides exceptional glare control<br />

Eliminates the need for hex louvers<br />

This innovative design minimizes<br />

wasted or stray light, which helps<br />

preserve nightime skies, <strong>RDB</strong><br />

<strong>Series</strong> inground uplights with<br />

SWW optics are<br />

Community<br />

Friendly.<br />

<strong>RDS</strong> Spot Optics – Fixed & Variable<br />

Continuous product improvement is an<br />

example of <strong>LSI</strong> <strong>Greenlee</strong>’s leadership<br />

Tighter beams - <strong>Inc</strong>reased punch<br />

Concentrated candle power<br />

ISS is standard


<strong>RDB</strong>/<strong>RDS</strong><br />

S e r i e s<br />

Lamp Types: Metal Halide, Mercury Vapor, High<br />

Pressure Sodium, <strong>Inc</strong>andescent, Low-Voltage, and<br />

Compact Fluorescent<br />

Housing: Compression molded, fiber-reinforced<br />

polymer housing provides high strength and UV<br />

stability. Warranted against corrosion for five<br />

years.<br />

Finish: Housing and standard slip-resistant<br />

composite lens retainer is black. Optional<br />

aluminum accessories are available in Black or<br />

Clear polyester powder coat. Brass accessories<br />

have a natural, as cast finish.<br />

Fasteners: All exposed fasteners are captive,<br />

black oxide coated, stainless steel.<br />

Lampholder: Matched to lamp/optics. Medium<br />

base is glazed porcelain, 4KV pulse rated, with<br />

spring center contact. Double ended HID are<br />

5KV pulse rated with silver plated contacts.<br />

Compact fluorescent are molded thermoplastic.<br />

LV Bi-pin are high temperature ceramic.<br />

Lens/Retainer: Tempered, heat resistant glass<br />

available with optional slip resistant etched<br />

pattern, or low-iron formulation. Cast brass and<br />

aluminum lens retainers are available in place of<br />

standard composite ring.<br />

Optics/Aiming: Flood and Spot optics with<br />

variable beams spreads are available. Precise<br />

beam spread, tilt, and rotation can all be locked<br />

into place. Max reflector tilt is 15° in <strong>RDS</strong>, and<br />

25° in <strong>RDB</strong>. Spot optics come standard with<br />

Internal Source Shields for glare control. Wall<br />

Wash optics have integral glare control devices.<br />

Reflector lamps from MR16 (<strong>RDS</strong>) through<br />

PAR56 (<strong>RDB</strong>) can be accommodated.<br />

Power Pack: Standard HID PPK is magnetic,<br />

high power factor, -20°F starting, with a Class H,<br />

180°C insulation system. Ballast and thermal<br />

protector are encapsulated in silica resin for heat<br />

control. PPK assembly has handle/finger holes<br />

for easy installation and service. Dissimilar quick<br />

connectors ensure error free assembly. Moldedin<br />

compartments (in housing) separate capacitor<br />

and ignitor from ballast heat. Fluorescent ballast<br />

is electronic, universal 120-277V 50/60HZ, rated<br />

for 0°F starting. Electronic ballasts for most metal<br />

halide lamps are an available option.<br />

Seal Pack and waterproof wire connectors are<br />

included to provide a high quality installation.<br />

<strong>RDB</strong><br />

<strong>RDB</strong> Optics<br />

*<br />

360º<br />

95°<br />

360º<br />

30°- 80°<br />

360º<br />

10°<br />

360º<br />

10°- 45°<br />

360º<br />

*<br />

360º<br />

SWW<br />

CMH 39, 70 150<br />

T6<br />

* Wall Wash<br />

FLF<br />

MH 50, 70, 100<br />

150, 175<br />

MV 50, 75, 100, 175<br />

HPS 50, 70, 100, 150<br />

Tilt up to 25º<br />

FLV<br />

MH 50, 70, 100<br />

150, 175<br />

MV 50, 75, 100, 175<br />

HPS 50, 70, 100, 150<br />

Tilt up to 25º<br />

SPF-Fixed Spot<br />

MH 50, 70, 100<br />

150, 175<br />

MV 50, 75, 100,175<br />

Tilt up to 25º<br />

SPV-Variable Spot<br />

MH 50, 70, 100,<br />

150, 175<br />

MV 50, 75, 100<br />

HPS 50, 70, 100, 150<br />

Tilt up to 25º<br />

RFL/PAR38<br />

MH 35, 70,100,175<br />

MV 50,100, 175<br />

*Depends on Lamp<br />

Tilt up to 25°<br />

<strong>RDB</strong> Dimensions<br />

<strong>RDB</strong> Accessories (only)<br />

Internal Directional<br />

Louver (IDL)<br />

Internal Non-<br />

Directional Louver<br />

(INL)<br />

Stainless Steel Rock<br />

Guard (RGS)


<strong>RDS</strong> Dimensions<br />

6.780o<br />

172,21mm<br />

13.643<br />

346,53mm<br />

1.994<br />

50,65mm<br />

6.432o<br />

163,37mm<br />

3/4-14 NPS<br />

THREADS (2X) .890<br />

1.688 22,61mm<br />

42,88mm<br />

9.250o<br />

234,95mm<br />

2.125<br />

53,98mm<br />

13.500<br />

9.176o 342,90mm<br />

233,07mm<br />

7.213o<br />

183,21mm<br />

<strong>RDS</strong> Accessories (only)<br />

Domed<br />

Directional<br />

Marker<br />

DMB-Shown<br />

DMA-CPP<br />

Available<br />

DMA-BLK<br />

Available<br />

Wall Wash Lens<br />

Standard w/AWW<br />

Optics<br />

Stainless Steel<br />

Rock Guard<br />

RGS-Shown<br />

<strong>RDS</strong><br />

<strong>RDS</strong> Optics<br />

*<br />

360º<br />

90°<br />

360º<br />

36°- 110°<br />

360º<br />

15°<br />

360º<br />

*<br />

360º<br />

AWW<br />

MH 50, 70, 100<br />

MV 50, 75, 100<br />

HPS 50, 70, 100<br />

* Wall Wash<br />

FLF<br />

MH 50, 70, 100<br />

MV 50, 75, 100<br />

HPS 50, 70, 100<br />

Tilt up to 15°<br />

FLV<br />

MH 50, 70, 100<br />

MV 50, 75, 100<br />

HPS 50, 70, 100<br />

Tilt up to 15°<br />

SPF<br />

MH 50, 70, 100<br />

MV 50, 75, 100<br />

HPS 50, 70, 100<br />

Tilt up to15º<br />

RFL<br />

MH 35, 70, 100PAR<br />

MV 50, 100 R-30<br />

* Depends On Lamp<br />

Tilt up to 15º<br />

<strong>LSI</strong> <strong>Greenlee</strong>’s <strong>RDB</strong>/<strong>RDS</strong><br />

family of round corrosion<br />

proof composite inground<br />

uplights provides these extra<br />

value features:<br />

RTL technology significantly reduces<br />

lens temperatures<br />

Variable Beam Spread Optics<br />

Rough-in housing RIH (with lens and<br />

retainer) can be shipped ahead for<br />

installation in concrete.<br />

Drive-over capability, up to 3,000pound<br />

vehicle weight<br />

Power Pack with Quick Connectors<br />

Interchangeable Optic Assemblies with<br />

Quick Connectors<br />

Seal Pack kit provided to seal junction<br />

box for a high quality installation<br />

Waterproof wire connectors provided<br />

for trouble-free operation<br />

Anti-Siphon Barrier


Rock Guard Aluminum<br />

RGA-CPP<br />

Directional Shield Aluminum<br />

DSA-CPP<br />

Aluminum Lens Retainer<br />

ALR-CPP<br />

Domed Directional Marker<br />

DMA-CPP<br />

<strong>RDS</strong> Only<br />

Rock Guard Aluminum<br />

RGA-BLK<br />

Directional Shield Aluminum<br />

DSA-BLK<br />

Aluminum Lens Retainer<br />

ALR-BLK<br />

Domed Directional Marker<br />

DMA-BLK<br />

<strong>RDS</strong> Only<br />

Rock Guard Brass<br />

RGB<br />

Directional Shield Brass<br />

DSB<br />

Brass Lens Retainer<br />

BLR<br />

Domed Directional<br />

Marker Brass<br />

DMB<br />

<strong>RDS</strong> Only<br />

© 2003 <strong>LSI</strong> <strong>Industries</strong><br />

<strong>LSI</strong> <strong>Greenlee</strong> Lighting<br />

1300 Hutton, Suite 110 • Carrollton,Texas 75006<br />

Phone: 972-466-1133 Fax: 972-446-2202<br />

www.lsi-industries.com<br />

45193:Rev3-1003-012<br />

Front Cover - Left Side: Lighting Designer - Schuler & Shook, Photographer Stephen Iski - Right Side: Lighting Designer & Photographer Roger M.Yanagita

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!