Fire detection equipment - VIS Security
Fire detection equipment - VIS Security
Fire detection equipment - VIS Security
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
www.apollo-fire.co.uk<br />
PRODUCT CATALOGUE 2009<br />
<strong>Fire</strong> <strong>detection</strong><br />
<strong>equipment</strong>
By Appointment to<br />
Her Majesty The Queen<br />
Manufacturers of <strong>Fire</strong> Detection<br />
& Alarm Products<br />
Apollo <strong>Fire</strong> Detectors Limited<br />
Hampshire<br />
Why Choose Apollo?<br />
• Largest independent smoke detector<br />
manufacturer in the world<br />
• Certified to all key international approvals<br />
• The best people work for Apollo<br />
• Trustworthy, integrity & supportive<br />
• Localised customer service worldwide<br />
• Ex stock delivery<br />
• 100% reliability, 100% tested<br />
• Open, digital protocol<br />
• Forwards and backwards product compatibility<br />
• World<br />
Class <strong>Fire</strong> Solutions<br />
Apollo - The Partner of Choice<br />
Apollo <strong>Fire</strong> Detectors Ltd. has specialised in the design and<br />
manufacture of high quality fire <strong>detection</strong> products since<br />
1980. In that time, the company has broadened its capability<br />
from a straightforward focus on conventional fire detectors<br />
to include the manufacture of sophisticated analogue<br />
addressable detectors and interfaces for monitoring and<br />
controlling <strong>equipment</strong> in fire protection systems.<br />
Apollo applies the most modern production techniques and has<br />
invested in sophisticated manufacturing <strong>equipment</strong> to ensure<br />
consistent high quality products and fast response to customer<br />
requirements. Through planned expansion, Apollo has reached a<br />
leading position in the market for professional fire detectors detectors and<br />
exports over over half of its its production to countries countries around the world.<br />
In 2007, Apollo Apollo unveiled unveiled a new brand brand identity, further cementing cementing<br />
its position as a world class fire solutions solutions provider.<br />
Based in Havant, Hampshire, Apollo operates from one site. All<br />
departments - Research and Development, Sales and Marketing,<br />
Manufacturing and Finance are located here.<br />
Apollo is a Halma company. Halma is a holding company for over 40<br />
subsidiaries worldwide, all engaged in specialist engineering activities.<br />
Information in this catalogue is given in good faith, but Apollo <strong>Fire</strong> Detectors cannot be held responsible for any omissions or errors. The<br />
company reserves the right to change specifications of products at any time without prior notice.
4<br />
6<br />
8<br />
24<br />
34<br />
40<br />
44<br />
52<br />
68<br />
How do Detectors Work?<br />
New Products<br />
Intelligent <strong>Fire</strong> Detection<br />
Discovery, XP95<br />
Conventional <strong>Fire</strong> Detection<br />
Orbis, Series 65<br />
Two-wire technology<br />
AlarmSense<br />
Wireless technology<br />
XPander<br />
Specialist Detectors<br />
Flame, Beam & Duct Detectors<br />
Audio Visual Signalling<br />
Sounders, Beacons, Sounder Beacons,<br />
Sounder Beacon Bases<br />
Interfaces<br />
Isolated, Non-Isolated, Mini, DIN-Rail<br />
78<br />
82<br />
86<br />
94<br />
102<br />
116<br />
120<br />
122<br />
129<br />
Manual Call Points<br />
Mounting Accessories<br />
Marine<br />
Discovery, Orbis<br />
Intrinsically Safe<br />
XP95, Orbis<br />
UL<br />
XP95A, Series 65A, Discovery UL<br />
Test Equipment and Maintenance<br />
Additional Services<br />
Loop Calculator, Training<br />
Approvals<br />
Index<br />
Contents
4 How do Detectors Work?<br />
How do<br />
Detectors<br />
Work?<br />
Ionisation smoke detector<br />
The sensing part of the detector consists of two<br />
chambers - an open, outer chamber and a semi-sealed<br />
reference chamber within. Mounted in the reference<br />
chamber is a low activity radioactive foil of Americium<br />
241 which enables current to flow between the inner and<br />
outer chambers when the detector is powered up. As<br />
smoke enters the detector, particles become attached to<br />
the ions, causing a reduction in current flow in the outer<br />
chamber and hence an increase in voltage measured at<br />
the junction between the two chambers. The voltage<br />
increase is monitored by the electronic circuitry which<br />
triggers the detector into the alarm state at a preset<br />
threshold. An externally visible red LED lights up when<br />
the detector changes to alarm state.<br />
Ionisation smoke detectors are good general-purpose<br />
detectors which respond well to fast-burning<br />
(flaming) fires and are widely used for property<br />
protection.<br />
Integrating ionisation smoke detector<br />
This type of detector works on the same principles as<br />
the ionisation smoke detector, but has modified signal<br />
processing circuitry which allows an alarm threshold to be<br />
present for up to 20 seconds without initiating an alarm.<br />
This type of detector is suitable for use in areas where<br />
transient high levels of smoke may be expected.<br />
Integrating effect in analogue addressable systems<br />
In XP95 systems, the integrating effect can be mimicked<br />
in both ionisation and optical smoke detectors by<br />
adjusting the control <strong>equipment</strong> software to cause an<br />
appropriate delay. Discovery smoke detectors should be<br />
set to Mode Two or Mode Four to achieve this effect.<br />
Optical (photo-electric) smoke detector<br />
Optical smoke detectors incorporate a pulsing infra-red<br />
LED located in a chamber within the housing of the<br />
detector. The chamber is designed to exclude light from<br />
any external source. At an angle to the LED is a photodiode<br />
which normally does not register the column of<br />
light emitted by the LED. In the event of smoke from a<br />
fire entering the chamber, the light pulse from the LED<br />
will be scattered and hence registered by the photodiode.<br />
If the photo-diode ‘sees’ smoke on the two<br />
following pulses, the detector changes into alarm state<br />
and the indicator LED lights up. The detector housing<br />
is identical to that of the ionisatio n detector but has<br />
an indicator LED which is clear in quiescent state but<br />
produces red light in alarm.<br />
Optical smoke detectors respond particularly well to<br />
slow-burning (smouldering) fires. They are widely<br />
used for life protection.
Heat detector<br />
Most conventional heat detectors operate by using a<br />
matched pair of thermistors to sense heat. One thermistor<br />
is exposed to the ambient temperature, the other is<br />
sealed. In normal conditions the two thermistors register<br />
similar temperatures, but, on the development of a fire,<br />
the temperature recorded by the exposed thermistor<br />
will increase rapidly, resulting in an imbalance of the<br />
thermistors, causing the detector to change into alarm<br />
state. Rate-of-rise detectors are designed to detect a fire<br />
as the temperature increases, but they also have a fixed<br />
upper limit at which the detector will go into alarm if the<br />
rate of temperature increase has been too slow to trigger<br />
the detector earlier.<br />
The Series 65 and AlarmSense CS (static response) heat<br />
detectors have only one thermistor. They change to the<br />
alarm state at a preset temperature.<br />
Externally, the heat detectors are distinguishable from<br />
the smoke detectors by having wide openings to the<br />
surrounding atmosphere to allow good movement of air<br />
around the external thermistor.<br />
A heat detector may be more appropriate than a<br />
smoke detector where the environment is dirty<br />
or smoky under normal conditions. It must be<br />
recognised, however, that any heat detector will<br />
respond only when a fire is well established and<br />
generating a high heat output.<br />
Multisensor detector<br />
A multisensor detector is basically an optical smoke<br />
detector - so it will respond well to smouldering fires. The<br />
addition of a heat sensing element allows the multisensor<br />
to give a response to fast burning (flaming) fires which is<br />
comparable to that of an ionisation detector.<br />
Multisensor detectors are general purpose detectors<br />
which respond well to a wide range of fires.<br />
How do Detectors Work?<br />
Carbon Monoxide (CO) detector<br />
Carbon Monoxide (CO) is a poisonous gas produced by<br />
combustion and a CO fire detector is used to indicate the<br />
outbreak of a fire by sensing the level of CO in the air.<br />
The detector has an electrochemical cell which senses CO,<br />
but not smoke or other combustion products. The cells<br />
do not require much power, so the detector can be made<br />
electrically compatible with ordinary smoke and heat<br />
detectors. Apollo manufacturers a CO detector as part of<br />
the Discovery range.<br />
CO detectors are particularly good at detecting deepseated,<br />
smouldering fires.<br />
Beam detector<br />
A beam detector is made up of three main parts: the<br />
transmitter, which projects a beam of infra-red light;<br />
the receiver which registers the light and produces an<br />
electrical signal; and the interface, which processes the<br />
signal and generates alarm or fault signals. When a fire<br />
develops, smoke particles obstruct the beam of light and,<br />
once a pre-set threshold has been exceeded, the detector<br />
will go into alarm.<br />
Beam detectors are designed to protect large<br />
open spaces such as atria, museums, churches and<br />
warehouses.<br />
Flame detector<br />
A flame detector is designed to detect either ultraviolet<br />
(UV) or infra-red (IR) radiation emitted by a fire. The XP95<br />
Dual IR flame detector is sensitive to low-frequency,<br />
flickering infra-red radiation. This means that the detector<br />
can operate even if the lens is contaminated by a layer of<br />
oil, dust, water vapour or ice.<br />
Flame detectors are effective in protecting areas<br />
where flaming fires may be expected.<br />
5
6 New Products<br />
New<br />
Products<br />
Apollo prides itself on being a leader in product<br />
innovation. Providing fire solutions that meet the<br />
demands of our customers is the main pillar of<br />
Apollo’s product development programme. We<br />
are constantly working with our customers to<br />
develop new products to meet their needs.<br />
A further commitment to Apollo’s customer focus<br />
has seen the Marketing team be strengthened<br />
by the introduction of three new product<br />
management roles. These dedicated personnel<br />
will be responsible for the future direction of the<br />
portfolio as well as the internal management of<br />
the ranges.<br />
A prime responsibility of the new roles is<br />
continuation of customer focused product<br />
development within Apollo and continuing to be<br />
the Partner of Choice.<br />
If you have any comments or suggestions on<br />
any new or existing products, feel free to email<br />
ideas@apollo-fire.co.uk
New products for 2009<br />
Discovery Upgrade<br />
The Discovery range has been subjected to a<br />
thorough revision of the electronics and this<br />
has resulted in significant improvement to the<br />
Multisensor detector capabilities. It is possible<br />
to read out virtually instantly the analogue<br />
values for smoke and heat separately.<br />
DIN-Rail Mains Input/Output Unit<br />
The DIN-Rail Mains Input/Output Unit provides<br />
a voltage-free, single pole change-over relay<br />
output and a monitored switch input. The<br />
unit supervises one or more normally-open<br />
switches connected to a single pair of cables.<br />
DIN-Rail Sounder Controller (5 Amperes)<br />
The DIN-Rail Sounder Controller (5 Amperes)<br />
is used to control the operation of a zone of<br />
externally powered sounders and report their<br />
status to the control panel.<br />
Deckhead Mounting Box<br />
The Deckhead Mounting Box gives extra<br />
protection to devices to be fitted in areas<br />
where there is the possibility of moisture or<br />
condensation ingressing through the rear of<br />
the of the base. This new version is suitable<br />
for a wider range of detector bases as well<br />
as Apollo’s AV bases.<br />
2009 – Under<br />
development<br />
New Products<br />
There are a number of new products due for<br />
launch during the course of 2009. They are at<br />
the early stages of development. When ready<br />
for launch the website, eMonitor and Monitor<br />
newsletters will announce this, so keep an eye<br />
out! Products currently under development, in<br />
no particular order include:<br />
XPander Input/Output Unit<br />
Locally Powered Zone Monitor<br />
DIN-Rail Zone Monitor for IS Heads<br />
110dB(A) Open-Area Sounder Beacon<br />
Marine 110dB(A) Open-Area Sounder Beacon<br />
Discovery CO/Heat Detector<br />
Sounder Controller 8 Amperes (Marine)<br />
Conventional Flush Mounted Smoke Detector<br />
Marine DIN-Rail Mains Input/Output Unit<br />
Marine Base Mounted Flame Detectors<br />
Discovery Open-Area Sounder Beacon<br />
UL approved Open-Area Sounder<br />
UL approved Releasing Control Module<br />
UL approved Mini Monitor Module<br />
7
108 Intelligent <strong>Fire</strong> Detection<br />
Intelligent<br />
<strong>Fire</strong><br />
Detection<br />
In an Intelligent system all devices have unique ‘addresses’ and are<br />
connected in loops to the control panel. Intelligent systems give advanced<br />
warning of a developing hazard and can pinpoint the individual device<br />
raising alarm. There are two types of intelligent system – those with<br />
‘distributed intelligence’ and those with ‘centralised intelligence’.<br />
In systems with distributed intelligence the detectors incorporate<br />
processors which can determine whether alarm levels of smoke or heat<br />
exist and can initiate action accordingly.<br />
Detectors in systems with centralised intelligence monitor the air around<br />
them for smoke or heat and transmit the data to the control panel on<br />
interrogation. The processor in the panel compares the values with stored<br />
values and determines whether a pre-alarm or alarm should be signalled.<br />
The advantages of distributed intelligence are local adaptation to<br />
environment and reduction of traffic on the supply and data wires. The<br />
advantage of centralised intelligence is the ability to upgrade a system very<br />
quickly and easily by upgrading the control panel.
Discovery is a range of high-specification,<br />
intelligent fire detectors developed to<br />
meet the requirements of sophisticated<br />
systems while providing engineers with<br />
an additional dimension in fire protection<br />
capability. Discovery has a ‘distributed<br />
intelligence system’ where decisions are<br />
made in the detector head as well as<br />
at the control panel. Drift compensation<br />
is also incorporated into the detector,<br />
allowing it to adapt to dirty or dusty<br />
environments, which reduces false alarms.<br />
Each detector in the Discovery range can operate in one<br />
of five response modes, which can be selected from the<br />
control panel or hand held programmer. The response<br />
characteristics have been carefully set so that the detectors<br />
comply with the requirements of the relevant part of<br />
EN54 in all response modes. Mode One will give a higher<br />
sensitivity to fire than Mode Five.<br />
Discovery gives you total reassurance in installations where<br />
adaptability to changing conditions and protection against<br />
unwanted alarms is paramount.<br />
Key features of Discovery include:<br />
• Rejection of transient signals<br />
• Flashing LED option<br />
• Five response modes for ease of optimisation to<br />
changing environments<br />
• Drift compensation to ensure constant sensitivity<br />
• Four bytes of non-volatile memory for user data<br />
• Alarm flag for fast alarm reporting<br />
• Conventional alarm facility during control panel<br />
processor fault<br />
• 360° visibility in alarm<br />
• Compatible with XP95 systems<br />
• Insect Resistant<br />
NEW FOR 2009!<br />
Intelligent <strong>Fire</strong> Detection<br />
DISCOVERY<br />
Discovery<br />
intelligent fire<br />
<strong>detection</strong><br />
The Discovery range has been subjected to a<br />
thorough revision of the electronics and this has<br />
resulted in significant improvement to the Multisensor<br />
detector capabilities. It is possible to read out virtually<br />
instantly the analogue values for smoke and heat<br />
separately.<br />
This enables panel manufacturers to develop features<br />
which will provide more effective management<br />
of false alarms. An example of this would be an<br />
increased smoke value which might normally lead to<br />
a pre-alarm or even an alarm. If the heat value is read<br />
out separately and it shows little or no rise it can be<br />
concluded that it is not smoke from a fire but steam<br />
which is causing the high smoke analogue value.<br />
9
10 Intelligent <strong>Fire</strong> Detection<br />
DISCOVERY<br />
Discovery Ionisation Smoke Detector<br />
The Discovery Ionisation Smoke Detector uses<br />
a low activity radioactive foil to detect fires by<br />
irradiating the air in the smoke chambers and<br />
causing a current flow. If smoke enters the<br />
chamber, the current flow is reduced leading<br />
to an alarm.<br />
Discovery Ionisation Smoke Detector 58000-500<br />
Discovery Optical Smoke Detector<br />
The Discovery Optical Smoke Detector works<br />
using the light scatter principle and is ideal for<br />
applications where slow-burning or smouldering<br />
fires are likely.<br />
Discovery Optical Smoke Detector 58000-600<br />
Discovery Heat Detector<br />
The Discovery Heat Detector, distinguishable<br />
by the low airflow resistant case, uses a single<br />
thermistor to sense the air temperature around<br />
the detector.<br />
Discovery Heat Detector 58000-400<br />
Discovery Multisensor Detector<br />
The Discovery Multisensor Detector comprises<br />
optical smoke and thermistor temperature sensors<br />
whose outputs are combined to give the final<br />
analogue value. As a result, the multisensor is<br />
useful over a wide range of applications and is<br />
highly immune to false alarms.<br />
Discovery Multisensor Detector 58000-700<br />
Discovery Carbon Monoxide Detector<br />
The Discovery Carbon Monoxide (CO) Detector is<br />
good at detecting deep-seated fires. Please note<br />
that CO detectors do not detect smoke particles<br />
or heat and are not universal replacements for<br />
smoke detectors.<br />
Discovery Carbon Monoxide Detector 58000-300<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
• Responds well to fast-burning, flaming fires<br />
• Designed to operate in a variety of<br />
environments<br />
• Remote test feature<br />
• Responds well to slow-burning, smouldering<br />
fires<br />
• Well suited for bedrooms and escape routes<br />
• Unaffected by wind or atmospheric pressure<br />
• Remote test feature<br />
• Ideal in environments that are dirty or smoky<br />
under normal conditions<br />
• Well suited for warehouses, loading bays and<br />
car parks<br />
• Unaffected by wind or atmospheric pressure<br />
• Remote test feature<br />
• Ideal for a wide range of applications<br />
• Enhanced false alarm management<br />
• Well suited for environments such as hotel<br />
bedrooms<br />
• Unaffected by wind or atmospheric pressure<br />
• Well suited for sensitive environments<br />
• Heat only, optical only options<br />
• Remote test feature<br />
• Enhanced <strong>detection</strong> capability<br />
• Early response to hot fires<br />
• Ideal for smouldering fires<br />
• Less susceptible to false alarms caused by<br />
steam than smoke alarms<br />
• Five response modes<br />
• Remote test feature
Intelligent Mounting Base<br />
All detectors in the Discovery range fit the<br />
Intelligent Mounting Base. The Mounting Base<br />
is a low insertion force base with stainless steel<br />
contacts for the detector terminals. XPERT cards<br />
are supplied with all bases.<br />
Intelligent Mounting Base 45681-210<br />
Intelligent Deep Base<br />
The Intelligent Deep Base is a mounting base for<br />
Discovery products which has an increased depth<br />
which allows for cables to be inserted into the<br />
side of the product.<br />
Intelligent Deep Base 45681-209<br />
Isolating Base<br />
The new style Isolating Base senses and detects<br />
short-circuit faults on Discovery loops and spurs.<br />
Isolating Base 45681-284<br />
Product will replace 45681-321 during 2009<br />
Isolator<br />
The Isolator is placed at intervals on the loop and<br />
ensures that, in the case of a short-circuit, only<br />
the section between the isolators will be affected.<br />
When the short-circuit is removed, the isolators<br />
automatically restore power and data to the<br />
isolated section.<br />
Isolator 55000-720<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
Intelligent <strong>Fire</strong> Detection<br />
DISCOVERY<br />
• XPERT addressing<br />
• One way fit<br />
• Locking feature to prevent unauthorised<br />
removal<br />
• Enables surface wiring<br />
• The equivalent of up to 20 smoke detectors<br />
may be installed between isolating bases<br />
• High brightness LED<br />
• Compatible with Discovery CO detector<br />
• Detects wiring short circuits using patented<br />
technology<br />
• Minimises disruption from short-circuits<br />
• Automatic de-isolation on short-circuit removal<br />
• The equivalent of up to 20 smoke detectors<br />
may be installed between isolators<br />
11
12 Intelligent <strong>Fire</strong> Detection<br />
DISCOVERY<br />
Isolator Base<br />
The Isolator Base is unique and designed to only<br />
accept the Isolator 55000-720.<br />
Isolator Base 45681-211<br />
Intelligent Low Power Relay Base<br />
The Low Power Relay Base incorporates a low<br />
power relay to control field <strong>equipment</strong> such as<br />
automatic door closers.<br />
Intelligent Low Power Relay Base 45681-242<br />
Intelligent Heater Base<br />
The Intelligent Heater Base is designed to be used<br />
in cold climates where environmental conditions<br />
could result in either icing or condensation<br />
affecting the operation of detectors. It is<br />
recommended that the heater base be used in<br />
conjunction with either a Waterproof Base Cover<br />
or Deckhead Mounting Box to minimise moisture<br />
ingress.<br />
Intelligent Heater Base 45681-219<br />
Waterproof Base Cover 45681-519<br />
Deckhead Mounting Box 45681-217<br />
MiniDisc Remote Indicator<br />
The MiniDisc Remote Indicator is a light-weight,<br />
compact LED indicator for use in fire protection<br />
systems.<br />
MiniDisc Remote Indicator 53832-070<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
• Only accepts isolators<br />
• Gives a set of voltage free contacts controlled<br />
by the remote output of a detector<br />
• Draws negligible current<br />
• Capable of switching up to 30V at 1A<br />
• Raises the ambient temperature of a detector<br />
chamber by approximately 10°C<br />
• Limits the risk of potential for lose of<br />
functionality caused to detectors installed in<br />
these conditions.<br />
• Can be used across the entire Apollo range<br />
• Small and discrete<br />
• Anti-tamper screw to protect against<br />
unauthorised removal
Ancillary devices available for the Discovery range:<br />
Intelligent <strong>Fire</strong> Detection<br />
DISCOVERY<br />
Product Name Part Number Page No.<br />
MOUNTING ACCESSORIES 82<br />
Backplate 45681-233 83<br />
Base Cover 45681-380 83<br />
Conduit Box 45681-204 83<br />
Sounder Ceiling Plate 45681-311 83<br />
Module Base 38531-822 83<br />
Deckhead Mounting Box 45681-217 84<br />
Metal Deckhead Mounting Box PG16 29600-131 84<br />
Metal Deckhead Mounting Box M20 29600-139 84<br />
Deckhead Adaptor PG16-M20 27249-005 84<br />
Detector Ceiling Tile Mounting Box 45681-309 84<br />
Sounder Ceiling Tile Mounting Box 45681-310 84<br />
Beacon Enclosure 29600-318 84<br />
DIN-Rail Interface Enclosure (4 units) 29600-239 85<br />
DIN-Rail Interface Enclosure (10 units) 29600-240 85<br />
1.5mm Hexagonal Driver 29600-095 85<br />
MANUAL CALL POINTS 78<br />
Discovery Manual Call Point Red (Surface) 58100-910 79<br />
Discovery Manual Call Point with Isolator Red (Surface) 58100-908 79<br />
Discovery Manual Call Point White 58100-926 79<br />
Discovery Manual Call Point Yellow 58100-927 79<br />
Discovery Manual Call Point Blue 58100-928 79<br />
Discovery Manual Call Point Green 58100-929 79<br />
Transparent Hinged Cover 26729-152 79<br />
Weatherproof Manual Call Point Red 58100-950 80<br />
Weatherproof Manual Call Point Red with Isolator 58100-951 80<br />
STANDARD INTERFACES 69<br />
Input/Output Unit 55000-847 70<br />
Three Channel Input/Output Unit 55000-588 70<br />
Three Channel Input/Output Unit PCB only 43781-588 70<br />
Output Unit 55000-849 70<br />
Sounder Control Unit 55000-852 70<br />
Switch Monitor 55000-843 71<br />
Switch Monitor Plus 55000-841 71<br />
Zone Monitor 55000-845 71<br />
MINI INTERFACES 73<br />
Mini Switch Monitor 55000-760 74<br />
Mini Switch Monitor with fly leads 55000-833 74<br />
Mini Switch Monitor with fly leads (Interrupt) 55000-832 74<br />
DIN-RAIL INTERFACES 75<br />
NEW!! DIN-Rail Sounder Controller (5 Amperes) 55000-182 76<br />
DIN-Rail Input/Output Unit 55000-803 76<br />
DIN-Rail Output Unit 55000-804 76<br />
DIN-Rail Switch Monitor 55000-822 76<br />
DIN-Rail Switch Monitor Plus 55000-821 77<br />
DIN-Rail Zone Monitor with Isolator 55000-812 77<br />
DIN-Rail Dual Isolator 55000-802 77<br />
13
14 Intelligent <strong>Fire</strong> Detection<br />
DISCOVERY<br />
Product Name Part Number Page No.<br />
AUDIO <strong>VIS</strong>UAL SIGNALLING<br />
Discovery Sounder Beacon Base 45681-393 65<br />
Intelligent Open-Area Sounder Red 55000-001 54<br />
Intelligent Open-Area Sounder White 55000-002 54<br />
Intelligent 100dB (A) Open-Area Sounder Red 55000-278 54<br />
Intelligent 100dB (A) Open-Area Sounder White 55000-279 54<br />
Intelligent 100dB (A) Open-Area Sounder Slow Whoop Red 55000-276 54<br />
Intelligent 100dB (A) Open-Area Sounder Slow Whoop White 55000-277 54<br />
Intelligent 100dB (A) Open-Area Weatherproof Sounder Red 55000-274 54<br />
Intelligent 100dB (A) Open-Area Weatherproof Sounder White 55000-275 54<br />
Integrated Base Sounder 45681-278 56<br />
Integrated Base Sounder with Isolator 45681-277 56<br />
Integrated Base Sounder Slow Whoop 45681-291 56<br />
Integrated Base Sounder Slow Whoop with Isolator 45681-290 56<br />
Integrated Base Sounder DIN-Tone with Isolator 45681-300 56<br />
White Cap 45681-292 56<br />
Red Cap 45681-293 56<br />
Intelligent Base Sounder 45681-265 56<br />
Intelligent Base Sounder, for use with Isolating Base 45681-266 56<br />
Intelligent Base Sounder Slow Whoop 45681-267 56<br />
Intelligent Base Sounder Slow Whoop for use with Isolating Base 45681-268 56<br />
White Cap 29600-256 56<br />
Red Cap 29600-257 56<br />
Ancillary Base Sounder 45681-276 56<br />
Intelligent Open-Area Beacon Red Lens 55000-009 59<br />
Intelligent Open-Area Beacon Clear Lens 55000-010 59<br />
Loop-Powered Beacon Red 55000-877 59<br />
Loop-Powered Beacon Amber 55000-879 59<br />
Loop-Powered Beacon Clear Lens/Red Flash 55000-878 59<br />
Beacon Enclosure 29600-318 59<br />
Loop-Powered Beacon Base with Isolator 45681-333 61<br />
Loop-Powered Beacon Base with Standard Flash 45681-335 61<br />
Loop-Powered Beacon Base with Australian Flash 45681-337 61<br />
Intelligent Open-Area Sounder Beacon Red Lens 55000-005 63<br />
Intelligent Open-Area Sounder Beacon Clear Lens 55000-006 63<br />
Multi-Tone Open-Area Sounder Beacon Red with Isolator 55000-293 63<br />
Multi-Tone Open-Area Sounder Beacon White with Isolator 55000-294 63<br />
Multi-Tone Open-Area Sounder Beacon Red 55000-291 63<br />
Multi-Tone Open-Area Sounder Beacon White 55000-292 63<br />
Weatherproof Multi-Tone Open-Area Sounder Beacon Red with Isolator 55000-298 63<br />
Weatherproof Multi-Tone Open-Area Sounder Beacon White with Isolator 55000-299 63<br />
Weatherproof Multi-Tone Open-Area Sounder Beacon Red 55000-296 63<br />
Weatherproof Multi-Tone Open-Area Sounder Beacon White 55000-297 63<br />
Sounder Beacon Base with Isolator 45681-330 65<br />
Sounder Beacon Base 45681-331 65<br />
Sounder Beacon Base with Australian Tone 45681-336 65<br />
Sounder Beacon Base with Isolator DIN-Tone 45681-334 65<br />
Sounder Beacon Base with NZ Tone 45681-338 65<br />
Sounder Beacon Base Slow Whoop with Isolator 45681-332 65<br />
Magnetic Wand 29650-001 67
Intelligent <strong>Fire</strong> Detection<br />
DISCOVERY<br />
15
16 Intelligent <strong>Fire</strong> Detection<br />
XP95<br />
XP95<br />
intelligent fire<br />
<strong>detection</strong><br />
The XP95 range of intelligent fire<br />
detectors is advanced in design, improved<br />
in performance and has unique features<br />
that benefit the installer and end user.<br />
The range features smoke detectors (ionisation and optical),<br />
standard and high temperature heat detectors and a<br />
multisensor. Beam detectors, flame detectors, manual call<br />
points, audio visual signalling devices, interface units and<br />
isolators complete the range. XP95 has a ‘central intelligence’<br />
system where all the decisions are made by the control panel.<br />
Apollo has always used an open, digital protocol since 1986<br />
and has ensured backward compatibility when developing new<br />
products. An open protocol allows freedom of choice for the<br />
fire system specifier, installer and end user. A system using<br />
a digital protocol is also much less susceptible to corruption<br />
than an analogue protocol and is therefore often preferred in a<br />
system which is life critical.<br />
Key features of XP95 include:<br />
• Alarm Flag for fast alarm reporting<br />
• Alarm Address for fast location of alarm<br />
• XPERT card addressing<br />
• Electronics-free base<br />
• Easy installation<br />
• Elegant design<br />
• Insect Resistant
XP95 Ionisation Smoke Detector<br />
The XP95 Ionisation Smoke Detector uses a low<br />
activity radioactive foil to detect fires by irradiating<br />
the air in the smoke chambers and causing a<br />
current flow. If smoke enters the chamber, the<br />
current flow is reduced leading to an alarm.<br />
XP95 Ionisation Smoke Detector 55000-500<br />
XP95 Ionisation Smoke Detector (Black) 55000-660<br />
XP95 Ionisation Smoke Detector (VdS) 55000-520<br />
XP95 Optical Smoke Detector<br />
The XP95 Optical Smoke Detector works using the<br />
light scatter principle and is ideal for applications<br />
where slow-burning or smouldering fires are likely.<br />
XP95 Optical Smoke Detector 55000-600<br />
XP95 Optical Smoke Detector (Black) 55000-660<br />
XP95 Optical Smoke Detector (VdS) 55000-620<br />
XP95 Heat Detector<br />
The XP95 Heat Detector monitors temperature by<br />
using a single thermistor network which provides<br />
a count output proportional to the external air<br />
temperature. The XP95 range features two Heat<br />
Detectors, standard and high temperature. The<br />
standard heat detector is classified as an A2S<br />
device and will report an alarm at 55°C. The high<br />
temperature detector, classified as a CS device,<br />
will report an alarm at 90°C.<br />
XP95 Heat Detector A2S 55000-400<br />
XP95 Heat Detector A2S (VdS) 55000-420<br />
XP95 Heat Detector CS 55000-401<br />
XP95 Multisensor Detector<br />
The XP95 Multisensor Detector contains an optical<br />
smoke sensor and a thermistor temperature<br />
sensor whose outputs are combined to give the<br />
final analogue value.<br />
XP95 Multisensor Detector 55000-885<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
Intelligent <strong>Fire</strong> Detection<br />
XP95<br />
• Responds well to fast-burning, flaming fires<br />
• Designed to operate in a variety of<br />
environments<br />
• Minimal effects from temperature, humidity,<br />
atmospheric pressure<br />
• Well protected against electromagnetic<br />
interference over a wide frequency range<br />
• Responds well to slow-burning, smouldering<br />
fires<br />
• Well suited for bedrooms and escape routes<br />
• Unaffected by wind or atmospheric pressure<br />
• Ideal in environments that are dirty or smoky<br />
under normal conditions<br />
• Well suited for warehouses, loading bays and<br />
car parks<br />
• Unaffected by wind or atmospheric pressure<br />
• Sensitive to a wide range of fires<br />
• Well suited for environments such as hotel<br />
bedrooms<br />
• Unaffected by wind or atmospheric pressure<br />
17
18 Intelligent <strong>Fire</strong> Detection<br />
XP95<br />
Intelligent Mounting Base<br />
All detectors in the XP95 range fit the Intelligent<br />
Mounting Base. The Mounting Base is a low<br />
insertion force base with stainless steel contacts<br />
for the detector terminals. XPERT cards are<br />
supplied with all bases.<br />
Intelligent Mounting Base 45681-210<br />
Intelligent Mounting Base (Black) 45681-361<br />
Isolating Base<br />
The new style Isolating Base senses and detects<br />
short-circuit faults on XP95 loops and spurs.<br />
Isolating Base 45681-284<br />
Product will replace 45681-321 during 2009<br />
Isolator<br />
The Isolator is placed at intervals on the loop and<br />
ensures that, in the case of a short-circuit, only<br />
the section between the isolators will be affected.<br />
When the short-circuit is removed, the isolators<br />
automatically restore power and data to the<br />
isolated section.<br />
Isolator 55000-720<br />
Isolator Base<br />
The Isolator Base is unique and designed to only<br />
accept the Isolator 55000-720.<br />
Isolator Base 45681-211<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
• XPERT addressing<br />
• One way fit of detector<br />
• Locking feature to prevent unauthorised<br />
removal<br />
• The equivalent of up to 20 smoke detectors<br />
may be installed between isolating bases<br />
• High brightness LED<br />
• Detects wiring short circuits using patented<br />
technology<br />
• Minimises disruption from short-circuits<br />
• Automatic de-isolation on short-circuit removal<br />
• The equivalent of up to 20 smoke detectors<br />
may be installed between isolators<br />
• Only accepts isolators
Intelligent Low Power Relay Base<br />
The Low Power Relay Base incorporates a low<br />
power relay to control field <strong>equipment</strong> such as<br />
automatic door closers.<br />
Intelligent Low Power Relay Base 45681-242<br />
Intelligent Deep Base<br />
The Intelligent Deep Base is a mounting base for<br />
XP95 products which has an increased depth which<br />
allows for cables to be inserted into the side of the<br />
product.<br />
Intelligent Deep Base 45681-209<br />
Intelligent Heater Base<br />
The Intelligent Heater Base is designed to be used<br />
in cold climates where environmental conditions<br />
could result in either icing or condensation<br />
affecting the operation of detectors. It is<br />
recommended that the heater base be used in<br />
conjunction with either a Waterproof Base Cover<br />
or Deckhead Mounting Box to minimise moisture<br />
ingress.<br />
Intelligent Heater Base 45681-219<br />
Waterproof Base Cover 45681-519<br />
Deckhead Mounting Box 45681-217<br />
MiniDisc Remote Indicator<br />
The MiniDisc Remote Indicator is a light-weight,<br />
compact LED indicator for use in fire protection<br />
systems.<br />
MiniDisc Remote Indicator 53832-070<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
Intelligent <strong>Fire</strong> Detection<br />
• Enables surface wiring<br />
XP95<br />
• Gives a set of voltage free contacts controlled<br />
by the remote output of a detector<br />
• Draws negligible current<br />
• Capable of switching up to 30V at 1A<br />
• Raises the ambient temperature of a detector<br />
chamber by approximately 10°C<br />
• Limits the risk of potential for loss of<br />
functionality caused to detectors installed in<br />
these conditions.<br />
• Can be used across the entire Apollo range<br />
• Small and discrete<br />
• Anti-tamper screw to protect against<br />
unauthorised removal<br />
19
20 Intelligent <strong>Fire</strong> Detection<br />
XP95<br />
Ancillary devices available for the XP95 range:<br />
Product Name Part Number Page No.<br />
MOUNTING ACCESSORIES 82<br />
Backplate 45681-233 85<br />
Base Cover 45681-380 83<br />
Conduit Box 45681-204 83<br />
Sounder Ceiling Plate 45681-311 83<br />
Module Base 38531-822 83<br />
NEW!! Deckhead Mounting Box 45681-217 84<br />
Metal Deckhead Mounting Box PG16 29600-131 84<br />
Metal Deckhead Mounting Box M20 29600-139 84<br />
Deckhead Adaptor PG16-M20 27249-005 84<br />
Detector Ceiling Tile Mounting Box 45681-309 84<br />
Sounder Ceiling Tile Mounting Box 45681-310 84<br />
Beacon Enclosure 29600-318 84<br />
DIN-Rail Interface Enclosure (4 units) 29600-239 85<br />
DIN-Rail Interface Enclosure (10 units) 29600-240 85<br />
Series 90 to XP95 Base Adaptor 45681-238 85<br />
1.5mm Hexagonal Driver 29600-095 85<br />
MANUAL CALL POINTS 78<br />
XP95 Manual Call Point Red (Surface) 55100-905 79<br />
XP95 Manual Call Point with Isolator Red (Surface) 55100-908 79<br />
Transparent Hinged Cover 26729-152 79<br />
STANDARD INTERFACES 69<br />
Input/Output Unit 55000-847 70<br />
Three Channel Input/Output Unit 55000-588 70<br />
Three Channel Input/Output Unit PCB only 43781-588 70<br />
Output Unit 55000-849 70<br />
Sounder Control Unit 55000-852 70<br />
Switch Monitor 55000-843 71<br />
Switch Monitor Plus 55000-841 71<br />
Zone Monitor 55000-845 71<br />
MINI INTERFACES 73<br />
Mini Switch Monitor 55000-760 74<br />
Mini Switch Monitor with fly leads 55000-833 74<br />
Mini Switch Monitor with fly leads (Interrupt) 55000-832 74<br />
DIN-RAIL INTERFACES 75<br />
NEW!! DIN-Rail Mains Input/Output Unit 55000-797 76<br />
NEW!! DIN-Rail Sounder Controller (5 Amperes) 55000-182 76<br />
DIN-Rail Input/Output Unit 55000-803 76<br />
DIN-Rail Output Unit 55000-804 76<br />
DIN-Rail Switch Monitor 55000-822 76<br />
DIN-Rail Switch Monitor Plus 55000-821 77<br />
DIN-Rail Zone Monitor with Isolator 55000-812 77<br />
DIN-Rail Dual Isolator 55000-802 77<br />
AUDIO <strong>VIS</strong>UAL SIGNALLING 52<br />
Intelligent Open-Area Sounder Red 55000-001 54<br />
Intelligent Open-Area Sounder White 55000-002 54<br />
Intelligent 100dB (A) Open-Area Sounder Red 55000-278 54<br />
Intelligent 100dB (A) Open-Area Sounder White 55000-279 54<br />
Intelligent 100dB (A) Open-Area Sounder Slow Whoop Red 55000-276 54
Intelligent <strong>Fire</strong> Detection<br />
Product Name Part Number Page No.<br />
Intelligent 100dB (A) Open-Area Sounder Slow Whoop White 55000-277 54<br />
Intelligent 100dB (A) Open-Area Weatherproof Sounder Red 55000-274 54<br />
Intelligent 100dB (A) Open-Area Weatherproof Sounder White 55000-275 54<br />
Integrated Base Sounder 45681-278 56<br />
Integrated Base Sounder with Isolator 45681-277 56<br />
Integrated Base Sounder Slow Whoop 45681-291 56<br />
Integrated Base Sounder Slow Whoop with Isolator 45681-290 56<br />
Integrated Base Sounder DIN-Tone with Isolator 45681-300 56<br />
White Cap 45681-292 56<br />
Red Cap 45681-293 56<br />
Intelligent Base Sounder 45681-265 56<br />
Intelligent Base Sounder, for use with Isolating Base 45681-266 56<br />
Intelligent Base Sounder Slow Whoop 45681-267 56<br />
Intelligent Base Sounder Slow Whoop for use with Isolating Base 45681-268 56<br />
White Cap 29600-256 56<br />
Red Cap 29600-257 56<br />
Ancillary Base Sounder 45681-276 56<br />
Intelligent Open-Area Beacon Red Lens 55000-009 59<br />
Intelligent Open-Area Beacon Clear Lens 55000-010 59<br />
Loop-Powered Beacon Red 55000-877 59<br />
Loop-Powered Beacon Amber 55000-879 59<br />
Loop-Powered Beacon Clear Lens/Red Flash 55000-878 59<br />
Beacon Enclosure 29600-318 59<br />
Loop-Powered Beacon Base with Isolator 45681-333 61<br />
Loop-Powered Beacon Base with Standard Flash 45681-335 61<br />
Loop-Powered Beacon Base with Australian Flash 45681-337 61<br />
Intelligent Open-Area Sounder Beacon Red Lens 55000-005 63<br />
Intelligent Open-Area Sounder Beacon Clear Lens 55000-006 63<br />
Multi-Tone Open-Area Sounder Beacon Red with Isolator 55000-293 63<br />
Multi-Tone Open-Area Sounder Beacon White with Isolator 55000-294 63<br />
Multi-Tone Open-Area Sounder Beacon Red 55000-291 63<br />
Multi-Tone Open-Area Sounder Beacon White 55000-292 63<br />
Weatherproof Multi-Tone Open-Area Sounder Beacon Red with Isolator 55000-298 63<br />
Weatherproof Multi-Tone Open-Area Sounder Beacon White with Isolator 55000-299 63<br />
Weatherproof Multi-Tone Open-Area Sounder Beacon Red 55000-296 63<br />
Weatherproof Multi-Tone Open-Area Sounder Beacon White 55000-297 63<br />
Sounder Beacon Base with Isolator 45681-330 65<br />
Sounder Beacon Base 45681-331 65<br />
Sounder Beacon Base with Australian Tone 45681-336 65<br />
Sounder Beacon Base with Isolator DIN-Tone 45681-334 65<br />
Sounder Beacon Base with NZ Tone 45681-338 65<br />
Sounder Beacon Base Slow Whoop with Isolator 45681-332 65<br />
XP95<br />
21
22 Intelligent <strong>Fire</strong> Detection<br />
XPERT CARDS<br />
XPERT<br />
cards<br />
intelligent fire<br />
<strong>detection</strong><br />
Apollo’s Intelligent ranges use patented<br />
XPERT cards. A unique XPERT card provides<br />
simple, user friendly and accurate<br />
identification of detector location where a<br />
coded card, inserted into the base, is read<br />
by any detector once plugged in. All the<br />
electronic components are in the detector<br />
but the location information is held in<br />
the base which saves time and increases<br />
accuracy during commissioning.
Blank XPERT Card<br />
A universal address card supplied with all bases.<br />
Using a coding guide, pips are removed to set the<br />
address of the inserted detector.<br />
Blank XPERT Card 38531-771<br />
Pre-Addressed XPERT Cards<br />
Pre-addressed XPERT cards are supplied with pips<br />
already removed.<br />
Pre-Addressed XPERT Cards 1-126 45682-127<br />
XPander XPERT Cards<br />
Intelligent <strong>Fire</strong> Detection<br />
XPERT CARDS<br />
• Simplifies and speeds up installation and<br />
commissioning<br />
• Uses patented, proven technology<br />
• Address remains the same, no matter how<br />
often detectors are replaced<br />
• Flexibility to create any address<br />
• Saves time and increases accuracy during<br />
commissioning<br />
• Uses patented, proven technology<br />
• Address remains the same, no matter how<br />
often detectors are replaced<br />
Product Name Part Number<br />
XPander Blank XPERT Card (White) 29600-413<br />
XPander Blank XPERT Card (Red) 29600-399<br />
XPander XPERT cards are not interchangeable with those used with XP95 and Discovery.<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
23
10 24<br />
Conventional <strong>Fire</strong> Detection<br />
Conventional<br />
<strong>Fire</strong><br />
Detection<br />
In conventional systems detectors are wired as<br />
a circuit or ‘zone’. They signal fire conditions to<br />
a control panel by changing from a high to low<br />
impedance. The panel detects this impedance<br />
change by current monitoring and identifies the<br />
zone. Individual detectors cannot be identified.
Orbis is a range of conventional<br />
detectors which has been developed<br />
with sophisticated technology previously<br />
only found in intelligent detectors. Orbis<br />
is a range with modern styling and<br />
incorporates a mounting base which<br />
saves installation time.<br />
Key features of Orbis:<br />
• Automatic drift compensation with DirtAlert ® warning<br />
• Patented FasTest ® which reduces the time taken to test<br />
detectors<br />
• SensAlert ® uses a flashing LED to indicate that the<br />
sensor is not operating correctly<br />
• StartUp for fast commissioning<br />
• Attractive and compact design<br />
• Electrically compatible with Series 60 and Series 65<br />
• Wide voltage and operating temperature ranges<br />
• Algorithms for transient rejection<br />
• Flashing LED option<br />
• 360° visibility of LEDs<br />
• Insect Resistant<br />
Conventional <strong>Fire</strong> Detection 11 25<br />
ORBIS<br />
Orbis<br />
conventional<br />
fire <strong>detection</strong>
10 26<br />
Conventional <strong>Fire</strong> Detection<br />
ORBIS<br />
Orbis Optical Smoke Detector<br />
The Orbis Optical Smoke Detector works using the<br />
well established light scatter principle, however,<br />
the sensing technology is radically different<br />
in design from previous optical detectors and<br />
significantly reduces false alarms.<br />
Orbis Optical Smoke Detector ORB-OP-12001-APO<br />
Orbis Optical Smoke Detector ORB-OP-12003-APO<br />
with flashing LED †<br />
Orbis Multisensor Detector<br />
The Orbis Multisensor detector benefits from<br />
the same false alarm reduction technology as<br />
the optical detector. It is a thermally enhanced<br />
smoke detector and so will not give an alarm<br />
from heat alone.<br />
Orbis Multisensor Detector ORB-OH-13001-APO<br />
Orbis Multisensor Detector ORB-OH-13003-APO<br />
with flashing LED †<br />
Orbis Heat Detector<br />
The Orbis Heat Detector monitors temperature by<br />
using a single thermistor network which provides<br />
a voltage output proportional to the external air<br />
temperature. There are seven classes of heat<br />
detectors in the Orbis range designed to suit a<br />
wide variety of operating conditions.<br />
Orbis Heat Detector<br />
Rate-of-Rise, MAT 50°C<br />
A1R - Standard ORB-HT-11001-APO<br />
A1R - with flashing LED †<br />
Static, MAT 50°C<br />
ORB-HT-11013-APO<br />
A1S - Standard ORB-HT-11166-APO<br />
A1S with flashing LED † ORB-HT-11167-APO<br />
A2S - Standard ORB-HT-11002-APO<br />
A2S - with flashing LED †<br />
Rate-of-Rise, MAT 65°C<br />
ORB-HT-11014-APO<br />
BR - Standard ORB-HT-11003-APO<br />
BR - with flashing LED †<br />
Static, MAT 65°C<br />
ORB-HT-11015-APO<br />
BS - Standard ORB-HT-11004-APO<br />
BS - with flashing LED †<br />
Rate-of-Rise, MAT 80°C<br />
ORB-HT-11016-APO<br />
CR - Standard ORB-HT-11005-APO<br />
CR - with flashing LED †<br />
Static, MAT 80°C<br />
ORB-HT-11017-APO<br />
CS - Standard ORB-HT-11006-APO<br />
CS - with flashing LED † ORB-HT-11018-APO<br />
MAT (Maximum Application Temperature)<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
† Does not have VdS approval<br />
• Responds well to slow-burning, smouldering fires<br />
• Performs well in black and white smoke<br />
• Extra confirmation of smoke before alarm<br />
signal is given<br />
• Reduced incidence of false alarms<br />
• Sensing chamber keeps out dust and other<br />
airborne contaminants<br />
• Operates over a broad range of voltages at<br />
extremes of temperature<br />
• Responds well to fast-burning, flaming fires<br />
• Reduced incidence of false alarms<br />
• Increased reliability of <strong>detection</strong><br />
• Sensing chamber keeps out dust and other<br />
airborne contaminants<br />
• Operates over a broad range of voltages at<br />
extremes of temperature<br />
• Can be used for applications where smoke<br />
detectors are unsuitable<br />
• Ideal in environments that are dirty or smoky<br />
under normal conditions<br />
• Reduced incidence of false alarms<br />
• Increased reliability of <strong>detection</strong><br />
Choosing a heat detector
Orbis LX Base<br />
The Orbis LX Base is a low cost mounting base for<br />
use with Orbis detectors.<br />
Orbis LX Base ORB-MB-00012-APO<br />
TimeSaver Base ®<br />
The TimeSaver Base ® is a completely new design<br />
that provides installers with an open working<br />
area with fixing holes shaped to allow a simple<br />
mounting procedure.<br />
TimeSaver Base ® ORB-MB-00001-APO<br />
TimeSaver Base ® LX<br />
(simplified) version<br />
ORB-MB-00002-APO<br />
TimeSaver Diode Base<br />
The TimeSaver Diode Base has the same design as<br />
the standard TimeSaver Base ® with the addition of<br />
a diode. It is used in systems which house active<br />
EOL monitoring for head removal.<br />
TimeSaver Diode Base ORB-DB-00003-APO<br />
TimeSaver Relay Base<br />
The TimeSaver Relay Base incorporates a singlepole<br />
voltage-free change-over contact for switching<br />
external <strong>equipment</strong>. When the detector changes<br />
to the alarm state, the relay is energised, causing<br />
the contact to change state. The contact will<br />
remain in this condition until the detector is reset.<br />
TimeSaver Relay Base ORB-RB-10004-APO<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
Conventional <strong>Fire</strong> Detection 11 27<br />
• Low cost option<br />
• Grouped terminals to make wiring easy<br />
• Two fixing centres<br />
• LED alignment mark<br />
• Cable stripping guide<br />
• Detector locking mechanism<br />
• Grouped terminals to make wiring easy<br />
• Two fixing centres<br />
• LED alignment mark<br />
• Cable stripping guide<br />
• Continuity link for voltage testing of zone<br />
wiring prior to commissioning<br />
• Detector locking mechanism<br />
• Other devices continue to work during<br />
unauthorised removal of detectors<br />
• Grouped terminals to make wiring easy<br />
• Two fixing centres<br />
• LED alignment mark<br />
• Cable stripping guide<br />
• Continuity link for voltage testing of zone<br />
wiring prior to commissioning<br />
• Detector locking mechanism<br />
• Capable of switching up to 30V at 1A<br />
ORBIS
10 28<br />
Conventional <strong>Fire</strong> Detection<br />
ORBIS<br />
Sav-Wire Base<br />
The Sav-Wire Base is designed to allow Orbis<br />
detectors to be used in ‘Sav-Wire’ <strong>detection</strong> and<br />
alarm systems.<br />
Sav-Wire Base ORB-SW-10005-APO<br />
TimeSaver Deep Base<br />
The TimeSaver Deep Base is a mounting base<br />
for Orbis products which has an increased depth<br />
which allows for cables to be inserted into the<br />
side of the product.<br />
TimeSaver Deep Base ORB-MB-00019-APO<br />
Orbis Heater Base<br />
The Orbis Heater base is designed to be used in<br />
cold climates where environmental conditions could<br />
result in either icing or condensation affecting the<br />
operation of detectors. It is recommended that<br />
the heater base be used in conjunction with either<br />
a Waterproof Base Cover or Deckhead Mounting<br />
Box to minimise moisture ingress.<br />
Orbis Heater Base ORB-HB-00020-APO<br />
Waterproof Base Cover 45681-519<br />
Deckhead Mounting Box 45681-217<br />
MiniDisc Remote Indicator<br />
The MiniDisc Remote Indicator is a light-weight,<br />
compact LED indicator for use in fire protection<br />
systems.<br />
MiniDisc Remote Indicator 53832-070<br />
Ancillary devices available for the Orbis range:<br />
• Grouped terminals to make wiring easy<br />
• Two fixing centres<br />
• LED alignment mark<br />
• Cable stripping guide<br />
• Detector locking mechanism<br />
• Can be used in ‘Sav-Wire’ systems<br />
• Enables surface wiring<br />
• Raises the ambient temperature of a detector<br />
chamber by approximately 10°C<br />
• Limits the risk of potential for loss of<br />
functionality caused to detectors installed in<br />
these conditions.<br />
• Can be used across the entire Apollo range<br />
• Small and discrete<br />
• Anti-tamper screw to protect against<br />
unauthorised removal<br />
Product Name Part Number Page No.<br />
MOUNTING ACCESSORIES 82<br />
Backplate 45681-233 85<br />
Conduit Box 45681-204 83<br />
Sounder Ceiling Plate 45681-311 83<br />
Polycarbonate Deckhead Mounting Box 45681-217 84<br />
Metal Deckhead Mounting Box PG16 29600-131 84<br />
Metal Deckhead Mounting Box M20 29600-139 84<br />
Deckhead Adaptor PG16-M20 27249-005 84<br />
Detector Ceiling Tile Mounting Box 45681-309 84<br />
Sounder Ceiling Tile Mounting Box 45681-310 84<br />
1.5mm Hexagonal Driver 29600-095 85<br />
Series 65 to Orbis Base Adaptor ORB-BA-10008-APO 85<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.
Series 65 incorporates well-proven<br />
sensing technologies together with<br />
advances in materials and electronics.<br />
Developed from the highly successful<br />
Series 60 range of detectors, Series<br />
65 includes a chip (integrated circuit)<br />
based on that used in XP95 analogue<br />
addressable detectors.<br />
Having a wide operating voltage of 9-33V, the Series 65<br />
detectors can be integrated into security systems, when used<br />
with a relay base. The range consists of ionisation, integrating<br />
ionisation and optical smoke detectors, four grades of heat<br />
detector and a range of bases.<br />
Each type of detector is available in three versions:<br />
• Standard<br />
• Flashing LED<br />
• Flashing LED and magnet operated test switch<br />
Key features of Series 65:<br />
• Wide operating voltage<br />
• Advanced electronic technology<br />
• Flashing LED option<br />
• Magnetic test switch option<br />
• Can be used on security systems<br />
• Electrically and mechanically compatible with Series 60<br />
• Proven <strong>detection</strong> performance<br />
Conventional <strong>Fire</strong> Detection 11 29<br />
SERIES 65<br />
Series 65<br />
conventional fire<br />
<strong>detection</strong>
10 30<br />
Conventional <strong>Fire</strong> Detection<br />
SERIES 65<br />
Series 65 Ionisation Smoke Detector<br />
The Series 65 Ionisation Smoke Detector uses a low<br />
activity radioactive foil to detect fires by irradiating<br />
the air in the smoke chambers and causing a<br />
current flow. If smoke enters the chamber, the<br />
current flow is reduced leading to an alarm.<br />
Series 65 Ionisation Smoke Detector 55000-217<br />
Series 65 Ionisation Smoke Detector 55000-216<br />
with flashing LED †<br />
Series 65 Ionisation Smoke Detector 55000-215<br />
with flashing LED and magnetic test switch †<br />
Series 65 Ionisation Smoke Detector 55000-208<br />
(French)*<br />
Series 65 Integrating Ionisation<br />
Smoke Detector<br />
Ionisation detectors use a low activity radioactive<br />
foil to detect fires by irradiating the air in the<br />
smoke chambers and causing a current flow.<br />
If smoke enters the chamber, the current flow<br />
is reduced leading to an alarm. Circuitry in the<br />
integrating Ionisation Smoke Detector protects<br />
against transient levels of smoke above the<br />
normal threshold for up to 20 seconds.<br />
Series 65 Integrating Ionisation 55000-220<br />
Smoke Detector<br />
Series 65 Integrating Ionisation 55000-219<br />
Smoke Detector with flashing LED †<br />
Series 65 Integrating Ionisation 55000-218<br />
Smoke Detector with flashing LED<br />
and magnetic test switch †<br />
Series 65 Optical Smoke Detector<br />
The Series 65 Optical Smoke Detector incorporates<br />
a pulsing LED located within the housing of the<br />
detector. The external detector moulding is<br />
identical to that of the ionisation detector but has<br />
an indicator LED which is clear in quiescent state<br />
but produces red light in alarm.<br />
Series 65 Optical Smoke Detector 55000-317<br />
Series 65 Optical Smoke Detector 55000-316<br />
with flashing LED †<br />
Series 65 Optical Smoke Detector with 55000-315<br />
flashing LED and magnetic test switch †<br />
Series 65 Optical Smoke Detector 55000-308<br />
(French)*<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
† Does not have VdS approval<br />
* Does not have LPCB or VdS approval<br />
• Responds well to fast burning, flaming fires<br />
• Designed to operate in a variety of<br />
environments<br />
• Wide operating voltage<br />
• Flashing LED and magnet operated test<br />
switch option<br />
• Responds well to fast burning, flaming fires<br />
• Designed to operate in environments where<br />
transient levels of smoke may be expected<br />
• Wide operating voltage<br />
• Flashing LED and magnet operated test<br />
switch option<br />
• Responds well to slow-burning, smouldering<br />
fires<br />
• Well suited for bedrooms and escape routes<br />
• Unaffected by wind or atmospheric pressure<br />
• Wide operating voltage<br />
• Flashing LED and magnet operated test<br />
switch option
Series 65 Heat Detector<br />
The Series 65 Heat Detector monitors temperature<br />
by using a dual thermistor network which provides<br />
a voltage output proportional to the external air<br />
temperature. There are 12 heat detectors in the<br />
Series 65 range designed to suit a wide variety of<br />
operating conditions.<br />
Series 65 Heat Detector<br />
Rate-of-Rise, MAT 50°C, MSRT 65°C<br />
A1R - Standard 55000-122<br />
A1R - flashing LED † 55000-121<br />
A1R - flashing LED and magnetic test † 55000-120<br />
Rate of Rise, MAT 65°C, MSRT 85°C<br />
BR - Standard 55000-127<br />
BR - flashing LED † 55000-126<br />
BR - flashing LED and magnetic test † 55000-125<br />
Rate-of-Rise, MAT 80°C, MSRT 100°C<br />
CR - Standard 55000-132<br />
CR - flashing LED † 55000-131<br />
CR - flashing LED and magnetic test † 55000-130<br />
Static, MAT 80°C, MSRT 100°C<br />
CS - Standard 55000-137<br />
CS - flashing LED † 55000-136<br />
CS - flashing LED and magnetic test † 55000-135<br />
MAT (Maximum Application Temperature)<br />
MSRT (Maximum Static Response Temperature)<br />
Series 65 Standard Base<br />
The Series 65 Standard Base has been designed<br />
to enable detectors to be fitted without the<br />
need of force – particularly useful when fitting<br />
to suspended ceilings. All Series 65 bases have<br />
a ‘one way only’ fit. They can be locked into<br />
place by a grub screw using a 1.5mm hexagonal<br />
screwdriver - part number 29600-095.<br />
Series 65 Standard Base 45681-200<br />
Series 65 Diode Base<br />
The Series 65 Diode Base is designed for use with<br />
conventional systems that have manual call points<br />
and detector bases on the same circuit. The base<br />
is fitted with a schottky diode on the “L1 IN” and<br />
“L1 OUT” wiring terminals. This base can only be<br />
used with compatible control <strong>equipment</strong>.<br />
Series 65 Diode Base 45681-201<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
† Does not have VdS approval<br />
Conventional <strong>Fire</strong> Detection 11 31<br />
SERIES 65<br />
• Can be used for applications where smoke<br />
detectors are unsuitable<br />
• Ideal environments that are dirty or smoky<br />
under normal conditions<br />
• Wide operating voltage<br />
• Flashing LED and magnet operated test<br />
switch option<br />
• Detector locking mechanism<br />
• One way fit<br />
• Easy to wire<br />
• Contains an earth connector<br />
• Contains no electrical parts<br />
• Detector locking mechanism<br />
• One way fit<br />
• Easy to wire<br />
• Contains an earth connector<br />
• Continues to work during unauthorised<br />
removal of detectors
10 32<br />
Conventional <strong>Fire</strong> Detection<br />
SERIES 65<br />
Series 65 Sav-Wire Base<br />
The Series 65 Sav-Wire Base is designed to allow<br />
Series 65 detectors to be used in ‘Sav-Wire’<br />
<strong>detection</strong> and alarm systems.<br />
Series 65 Sav-Wire Base 45681-206<br />
Series 65 Standard Relay Base<br />
The Series 65 Standard Relay Base provides one<br />
set of volt-free, changeover (form C) contacts that<br />
change state when the detector signals an alarm.<br />
Series 65 Standard Relay Base 45681-245<br />
Series 65 Auxiliary Relay Base<br />
The Series 65 Auxiliary Relay Base provides two<br />
sets of volt-free changeover contacts to facilitate<br />
the switching of a remote LED or other auxiliary<br />
device.<br />
Series 65 Auxiliary Relay Base 45681-246<br />
Series 65 End-of-Line Relay Base<br />
The Series 65 End-of-Line (EOL) Relay Base is<br />
intended for use with 4-wire circuits and features<br />
two sets of changeover contacts and a power<br />
supervision relay.<br />
Series 65 End-of-Line Relay Base 12V 45681-247<br />
Series 65 End-of-Line Relay Base 24V 45681-248<br />
Series 65 12V Relay Base<br />
The Series 65 12V Relay Base is designed for use<br />
in both fire and security systems. For fire systems<br />
a jumper on the PCB is fitted to a ‘latching’<br />
position. For security systems the jumper is<br />
moved to another position so that the base is<br />
non-latching.<br />
Series 65 12V Relay Base 45681-508<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
• Detector locking mechanism<br />
• One way fit<br />
• Easy to wire<br />
• Contains an earth connector<br />
• Detects the removal of a detector head and<br />
reports a fault<br />
• Detector locking mechanism<br />
• One way fit<br />
• Easy to wire<br />
• Contains an earth connector<br />
• Detector locking mechanism<br />
• One way fit<br />
• Easy to wire<br />
• Contains an earth connector<br />
• Detector locking mechanism<br />
• One way fit<br />
• Easy to wire<br />
• Contains an earth connector<br />
• Detector locking mechanism<br />
• One way fit<br />
• Easy to wire<br />
• Contains an earth connector<br />
• Can be used in fire and security systems
MiniDisc Remote Indicator<br />
The MiniDisc Remote Indicator is a light-weight,<br />
compact LED indicator for use in fire protection<br />
systems.<br />
MiniDisc Remote Indicator 53832-070<br />
Ancillary devices available for the Series 65 range:<br />
Conventional <strong>Fire</strong> Detection 11 33<br />
SERIES 65<br />
• Can be used across the entire Apollo range<br />
• Small and discrete<br />
• Anti-tamper screw to protect against<br />
unauthorised removal<br />
Product Name Part Number Page No.<br />
MOUNTING ACCESSORIES 82<br />
Backplate 45681-233 85<br />
Series 65 Base Cover 45681-370 83<br />
Conduit Box 45681-204 83<br />
Module Base 38531-822 83<br />
Metal Deckhead Mounting Box PG16 29600-131 84<br />
Metal Deckhead Mounting Box M20 29600-139 84<br />
Deckhead Adaptor PG16-M20 27249-005 84<br />
Detector Ceiling Tile Mounting Box 45681-309 84<br />
1.5mm Hexagonal Driver 29600-095 85<br />
AUDIO <strong>VIS</strong>UAL SIGNALLING 52<br />
Series 65 Sounder Base 45681-512 57<br />
Series 65 Sounder Base with diode 45681-513 57<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.
10 34<br />
Two-Wire Technology<br />
Two-Wire<br />
Technology<br />
In conventional systems, detectors are hard wired<br />
into a circuit or zone. They signal a fire condition<br />
to a control panel by changing from a high to low<br />
impedance. The panel detects this impedance<br />
change by current monitoring and identifies the<br />
zone. Individual detectors cannot be identified. In<br />
two-wire conventional systems, fire <strong>detection</strong> and<br />
alarm products are connected to the same pair<br />
of supply wires, making installation quicker, less<br />
expensive and more flexible than traditional fourwire<br />
systems. Two-wire systems are particularly<br />
well suited for small to medium sized buildings.
AlarmSense has been developed to<br />
make the design and installation of a<br />
fire <strong>detection</strong> and alarm system easier<br />
and more economic for small to medium<br />
sized buildings. The range also allows<br />
an existing system to be extended or<br />
modified if necessary. This flexibility<br />
makes AlarmSense an excellent choice<br />
for use in HMOs.<br />
The AlarmSense range incorporates a number of technologically<br />
advanced features such as patented RemovAlert which<br />
alerts the control panel if a detector has been removed<br />
without authorisation.<br />
The entire AlarmSense range has been designed to enable<br />
compliance with BS5839-1 and BS5839-6 in addition to EN54<br />
standards. AlarmSense is also compliant with the Construction<br />
Products Directive (CPD).<br />
Key features of AlarmSense include:<br />
• Patented RemovAlert head removal monitoring<br />
• Local and general alarm switching<br />
• Reduced wiring costs<br />
• Quick and simple installation<br />
• False alarm reduction with ‘non-priority’ signalling<br />
• Flexible system design<br />
• Failsafe operation of manual call points<br />
• Detectors and call point alarms identifiable separately<br />
Two-Wire Technology 11 35<br />
ALARMSENSE<br />
AlarmSense<br />
two-wire<br />
technology
10 36<br />
Two-Wire Technology<br />
ALARMSENSE<br />
AlarmSense Optical Smoke Detector<br />
The AlarmSense Optical Smoke Detector works<br />
using the light scatter principle. The detector<br />
changes to alarm state at a pre-set threshold of<br />
smoke penetration into the sensing chamber.<br />
AlarmSense Optical Smoke Detector 55000-390<br />
AlarmSense Integrating Optical<br />
Smoke Detector<br />
The AlarmSense Integrating Optical Smoke<br />
Detector works using the light scatter principle.<br />
The detector changes to alarm state at a pre-set<br />
threshold of smoke penetration into the sensing<br />
chamber. The detector also has the ability to<br />
monitor and discard transient sources of smoke.<br />
AlarmSense Integrating 55000-391<br />
Optical Smoke Detector<br />
AlarmSense Heat Detector<br />
There are two heat detectors in the AlarmSense<br />
range designed to suit a wide variety of operating<br />
conditions. A static heat detector (CS) which<br />
responds only when a fixed temperature has been<br />
reached and a rate-of-rise detector (A1R) which<br />
has a fixed upper limit, but in addition, measures<br />
the rate of increase in temperature.<br />
AlarmSense Heat Detector A1R 55000-190<br />
AlarmSense Heat Detector CS 55000-193<br />
AlarmSense Base<br />
AlarmSense detectors can only be mounted into<br />
the AlarmSense Base. The base is used for installing<br />
detectors that do not require an integral sounder or<br />
sounder beacon.<br />
AlarmSense Base 45681-244<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
• Responds well to slow-burning, smouldering fires<br />
• Well suited for bedrooms and escape routes<br />
• 360° visibility of LEDs<br />
• Reduces false alarms<br />
• Quick and simple installation<br />
• Responds well to slow-burning, smouldering fires<br />
• Well suited for bedrooms and escape routes<br />
• 360° visibility of LEDs<br />
• Quick and simple installation<br />
• Designed to operate in environments where<br />
transient levels of smoke may be expected<br />
• Reduces false alarms<br />
• Can be used for applications where smoke<br />
detectors are unsuitable<br />
• Ideal environments that are dirty or smoky<br />
under normal conditions<br />
• CS detectors are ideal for use in environments<br />
with rapid temperature fluctuations such as<br />
boiler rooms<br />
• Reduction of false alarms<br />
• 360° visibility of LEDs<br />
• Quick and simple installation<br />
• Detects the removal of a detector head and<br />
reports a fault<br />
• Continues to work during unauthorised<br />
removal of detectors<br />
• Quick and simple installation
AlarmSense Alarm Relay<br />
The AlarmSense Alarm Relay enables devices such<br />
as beacons, pillow/bed alarms and radio vibrating or<br />
paging devices to be connected to the fire <strong>detection</strong><br />
system. This allows the system to comply with the<br />
requirements of the DDA.<br />
AlarmSense Alarm Relay 55000-835<br />
MiniDisc Remote Indicator<br />
The MiniDisc Remote Indicator is a light-weight,<br />
compact LED indicator for use in fire protection<br />
systems.<br />
MiniDisc Remote indicator 53832-070<br />
AlarmSense Manual Call Point<br />
The AlarmSense Manual Call Point is compliant<br />
with EN54:11. It is different from other<br />
conventional call points in that it can be detected<br />
as an operated call point rather than a detector<br />
that has changed to the alarm state.<br />
AlarmSense Manual Call Point 55100-894<br />
(Surface)<br />
AlarmSense Sounder Base<br />
The AlarmSense Sounder Base can only be<br />
used with AlarmSense detectors. It is fitted with<br />
electronic circuitry to monitor the presence of<br />
detectors and signals any unauthorised removal<br />
of detector heads. It is supplied with a high or low<br />
volume setting and red or white caps are available<br />
for stand-alone installation<br />
AlarmSense Sounder Base LR 45681-341<br />
AlarmSense Sounder Base 45681-510<br />
Red Cap 45681-295<br />
White Cap 45681-294<br />
AlarmSense Sounder Beacon Base<br />
The AlarmSense Sounder Beacon Base is designed<br />
to be used with AlarmSense detectors only.<br />
AlarmSense Sounder Beacon Base LR 45681-340<br />
AlarmSense Sounder Beacon Base 45681-509<br />
Red Cap 45681-295<br />
White Cap 45681-294<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
Two-Wire Technology 11 37<br />
• Ensures DDA compliance<br />
ALARMSENSE<br />
• Can be used across the entire Apollo range<br />
• Small and discrete<br />
• Anti-tamper screw to protect against<br />
unauthorised removal<br />
• Gives immediate response<br />
• Unique identification signalling<br />
• Resettable element<br />
• Detects the removal of a detector head and<br />
reports a fault<br />
• Continues to work during unauthorised<br />
removal of detectors<br />
• Quick and simple installation<br />
• Provides audible signal and <strong>detection</strong> at<br />
one point<br />
• High and low volume ranges<br />
• Sounder range between 70dB(A) and 87dB(A)<br />
• Detects the removal of a detector head and<br />
reports a fault<br />
• Continues to work during unauthorised<br />
removal of detectors<br />
• Quick and simple installation
10 38<br />
Two-Wire Technology<br />
ALARMSENSE<br />
Ancillary devices available for the AlarmSense range:<br />
Product Name Part Number Page No.<br />
MOUNTING ACCESSORIES 82<br />
Backplate 45681-233 83<br />
Conduit Box 45681-204 83<br />
Sounder Ceiling Plate 45681-311 83<br />
Module Base 38531-822 83<br />
Metal Deckhead Mounting Box PG16 29600-131 84<br />
Metal Deckhead Mounting Box M20 29600-139 84<br />
Deckhead Adaptor PG16 - M20 27249-005 84<br />
Detector Ceiling Tile Mounting Box 45681-309 84<br />
Sounder Ceiling Tile Mounting Box 45681-310 84<br />
1.5mm Hexagonal Driver 29600-095 85<br />
MANUAL CALL POINTS 78<br />
AlarmSense Manual Call Point (Surface) 55100-894 80<br />
AlarmSense Manual Call Point (Flush) 55100-893 80<br />
AUDIO <strong>VIS</strong>UAL SIGNALLING 52<br />
AlarmSense Sounder Base LR 45681-341 57<br />
AlarmSense Sounder Base 45681-510 57<br />
AlarmSense Sounder Beacon Base LR 45681-340 65<br />
AlarmSense Sounder Beacon Base 45681-509 65<br />
White Cap 45681-294 65<br />
Red Cap 45681-295 65<br />
Apollo makes ordering AlarmSense products for a project easy with a<br />
selection of detector/sounder base or detector/sounder beacon base<br />
packages. See pages 57 and 65 for a description of the AlarmSense<br />
Sounder Base and Sounder Beacon Base.<br />
Sounder Base Combination Part Number<br />
With Optical Smoke Detector 55000-392<br />
With Integrating Optical Smoke Detector 55000-393<br />
With A1R Heat Detector 55000-196<br />
With CS Heat Detector 55000-197<br />
Sounder Beacon Base Combination Part Number<br />
With Optical Smoke Detector 55000-394<br />
With Integrating Optical Smoke Detector 55000-395<br />
With A1R Heat Detector 55000-198<br />
With CS Heat Detector 55000-199
Two-Wire Technology 11 39<br />
ALARMSENSE
10 40<br />
Wireless Technology<br />
Wireless<br />
Technology<br />
Traditionally, fire <strong>detection</strong> systems in industrial<br />
and commercial applications have used hard wired<br />
installations. These systems are generally installed<br />
at the time of construction or refurbishment,<br />
making the laying of cables less of an issue. Certain<br />
applications do not lend themselves to this approach,<br />
such as occupied buildings, heritage sites, palaces,<br />
annexes etc. - this is where wireless systems<br />
provide the ideal solution.
XPander is a system in which individual<br />
detectors, call points and alarm devices<br />
communicate with the XP95 loop by<br />
radio signals. An interface is connected<br />
to the loop in the same way as any other<br />
interface, such as an input/output unit.<br />
Every XPander device is assigned an address and this<br />
address is recognised by the control panel in the same<br />
way as the address of any other device connected directly<br />
to the loop wiring. The XPander range benefits from the<br />
patented XPERT technology that is also used in Discovery<br />
and XP95. See page 23 for more details.<br />
XPander can be incorporated into fire <strong>detection</strong> systems in<br />
stately homes and architecturally sensitive buildings where<br />
the use of fire cables is either impractical or undesirable.<br />
Key features of XPander include:<br />
• Easy to install<br />
• XPERT card addressing<br />
• Self-monitoring<br />
• Proven technology<br />
• No special control panel needed<br />
• 868MHz radio channels<br />
• Up to 15 devices per interface<br />
• Up to 5 interfaces per loop<br />
All detectors within the XPander range are sold with<br />
mounting bases.<br />
Please ensure that you have attended an approved XPander<br />
training course prior to purchasing products from the<br />
XPander range.<br />
A site survey tool must be included in the first order of<br />
XPander products as a site survey must be carried out prior<br />
to installation.<br />
Wireless Technology 11 41<br />
XPANDER<br />
XPander<br />
wireless technology
10 42<br />
Wireless Technology<br />
XPANDER<br />
XPander Optical Smoke Detector<br />
and Mounting Base<br />
The XPander Optical Smoke Detector works on the<br />
light scatter principle and is ideal for applications<br />
where slow-burning or smouldering fires are likely.<br />
XPander Optical Smoke Detector<br />
and Mounting Base XPA-CB-12034-APO<br />
XPander Multisensor Detector and<br />
Mounting Base<br />
The XPander Multisensor Detector contains<br />
an optical smoke sensor and a thermistor<br />
temperature sensor whose outputs are combined<br />
to give the final analogue value.<br />
XPander Multisensor Detector<br />
and Mounting Base XPA-CB-13032-APO<br />
XPander Heat Detector and<br />
Mounting Base<br />
There are two heat detectors in the XPander<br />
range designed to suit a wide variety of operating<br />
conditions. A static heat detector (CS) which<br />
responds only when a fixed temperature has been<br />
reached and a rate-of-rise detector (A1R) which<br />
has a fixed upper limit, but in addition, measures<br />
the rate of increase in temperature.<br />
XPander Heat Detector and Mounting Base<br />
Rate-of-Rise (A1R) XPA-CB-11170-APO<br />
Static (CS) XPA-CB-11171-APO<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
• Responds well to slow-burning, smouldering<br />
fires<br />
• Well suited for bedrooms and escape routes<br />
• Modified to function with the low current<br />
requirements of radio systems<br />
• Bi-directional (monitored) radio platform<br />
• Easy to install<br />
• Powered by two independent packs of 3 AA<br />
alkaline batteries with a typical three year life<br />
• Sensitive to a wide range of fires<br />
• Well suited for environments such as hotel<br />
bedrooms<br />
• Modified to function with the low current<br />
requirements of radio systems<br />
• Bi-directional (monitored) radio platform<br />
• Easy to install<br />
• Powered by two independent packs of 3 AA<br />
alkaline batteries with a typical three year life<br />
• Can be used in applications where smoke<br />
detectors are unsuitable<br />
• Ideal environments that are dirty or smoky<br />
under normal conditions<br />
• CS detectors are ideal for use in environments<br />
with rapid temperature fluctuations such as<br />
boiler rooms<br />
• Modified to function with the low current<br />
requirements of radio systems<br />
• Bi-directional (monitored) radio platform<br />
• Easy to install<br />
• Powered by two independent packs of 3 AA<br />
alkaline batteries with a typical three year life
XPander Loop Interface<br />
The XPander Loop Interface communicates<br />
between the Intelligent control panel and the<br />
XPander detectors as the detectors alone can’t<br />
communicate directly with the panel.<br />
XPander Interface Unit XPA-IN-14007-APO<br />
XPander Survey Tool<br />
The XPander Survey Tool is used at the site<br />
survey stage to ascertain if a site is suitable for an<br />
XPander installation. A site survey must be carried<br />
out before XPander can be installed.<br />
XPander Survey Tool XPA-TE-14010-APO<br />
Ancillary devices available for the XPander range:<br />
Wireless Technology 11 43<br />
• Tests for radio signal strength<br />
XPANDER<br />
• Connects up to 15 XPander devices to a<br />
XP95 loop<br />
• Translates radio signals from XPander<br />
detectors to the control panel<br />
• Incorporates an integral loop isolator and is<br />
polarity sensitive<br />
There are two aerials available to complement the XPander range:<br />
• XPander External Aerial (XPA-AE-14008-APO) which is used to strengthen the radio signals<br />
sent between the XPander Interface Unit and XPander devices.<br />
• XPander External Directional Aerial (XPA-AE-14009-APO) which is used to pick up radio signals<br />
from outbuildings and annexes.<br />
Product Name Part Number Page No.<br />
XPander Manual Call Point XPA-MC-14006-APO 80<br />
XPander Sounder and Sounder Base Red XPA-CB-14001-APO 54<br />
XPander Sounder and Sounder Base White XPA-CB-14002-APO 54<br />
XPander Red Sounder Beacon and Red Sounder Base XPA-CB-14003-APO 63<br />
XPander Amber Sounder Beacon and White Sounder Base XPA-CB-14004-APO 63<br />
XPander Clear Sounder Beacon and White Sounder Base XPA-CB-14005-APO 63<br />
XPander Blank XPERT Card (White) 29600-413<br />
XPander Blank XPERT Card (Red) 29600-399<br />
XPander XPERT cards are not interchangeable with those used with Discovery and XP95.<br />
XPander Sounder and<br />
Sounder Base Red<br />
XPA-CB-14001-APO<br />
XPander Red Sounder Beacon<br />
and Red Sounder Base<br />
XPA-CB-14003-APO<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
XPander Manual Call Point<br />
XPA-MC-14006-APO
44<br />
Specialist Detectors<br />
Specialist<br />
Detectors<br />
In addition to standard detectors, Apollo offer a<br />
range of specialist detectors suitable for a wide<br />
variety of applications.
Flame detectors are effective in<br />
protecting areas where flaming fires<br />
may be expected.<br />
There is a choice of <strong>detection</strong><br />
techniques - Ultra Violet and Infra-red,<br />
or a combination of both.<br />
UV Flame Detectors are generally<br />
used in engine rooms, factories and<br />
warehouse applications.<br />
Infra-red Flame Detectors are able to<br />
tolerate dirtier environments which<br />
may block UV radiation and are<br />
generally used in applications such as<br />
waste handling, colour printing and<br />
paper manufacturing.<br />
Specialist Detectors 45<br />
FLAME DETECTORS<br />
Flame<br />
Detectors<br />
specialist detectors
46<br />
Specialist Detectors<br />
FLAME DETECTORS<br />
Intelligent Dual IR Flame Detector<br />
The Intelligent Dual Infra-Red (IR²) Flame Detector<br />
is designed for use in areas where flaming fires<br />
may be expected. The detector has two sensors<br />
which respond to different IR wavelengths to<br />
discriminate between flames and spurious sources<br />
of radiation. Applications include aircraft hangars,<br />
coal handling and paper manufacturing plants and<br />
woodworking environments.<br />
Intelligent IR² Flame Detector 55000-280<br />
Intelligent Flameproof IR²<br />
Flame Detector<br />
55000-295<br />
Intelligent Triple IR Flame Detector<br />
The Intelligent Triple IR Flame Detector (IR³) is<br />
designed to protect areas where open flaming<br />
fires may be expected. It is sensitive to lowfrequency,<br />
flickering infra-red radiation emitted by<br />
flames during combustion.<br />
Intelligent IR³ Flame Detector 55000-020<br />
Intelligent Flameproof IR³ Flame<br />
Detector<br />
55000-021<br />
Flame Detector Bracket<br />
The Flame Detector Bracket is an optional accessory<br />
for the Intelligent Flame Detectors. It is a stainless<br />
steel mounting bracket adjustable in two axis. Not<br />
suitable for Base Mounted Flame Detectors<br />
Flame Detector Bracket 29600-203<br />
Flame Detector Weather Shield<br />
The Flame Detector Weather Shield protects the<br />
device from inclement conditions.<br />
Flame Detector Weather Shield 29600-206<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
• Sensitive to flickering IR radiation<br />
• Detects through films of oil, dust, water<br />
and ice<br />
• Responds to flickering flames, including<br />
those invisible to the naked eye<br />
• Compatible with Discovery and XP95 protocols<br />
• Remote optical self-test function<br />
• 90° field of view<br />
• Up to 40m coverage<br />
• Loop-powered<br />
• Sensitive to flickering IR radiation<br />
• Detects through films of oil, dust, water<br />
and ice<br />
• Responds to flickering flames, including those<br />
invisible to the naked eye<br />
• False alarms due to lighting or flickering<br />
sunlight are minimised<br />
• Compatible with Discovery and XP95 protocols<br />
• Allows flame detector to be moved to desired<br />
position<br />
• Protects against water ingress<br />
• Protects sensor from direct sunlight
Intelligent Base Mounted UV Flame<br />
Detector<br />
The Intelligent Base Mounted UV Flame Detector<br />
is designed to protect internal areas where open<br />
fires may be expected. The detector has a single<br />
UV sensor with a narrow spectral response in<br />
order to discriminate between flames and most<br />
spurious sources of radiation.<br />
Intelligent Base Mounted UV Flame 55000-022<br />
Detector<br />
Base Mounted Flame Detector Bracket 29600-458<br />
Intelligent Base Mounted UV IR²<br />
Flame Detector<br />
The Intelligent Base Mounted UV IR² Flame<br />
Detector is designed to protect areas where open<br />
flaming fires may be expected. The detector has<br />
a UV and dual IR sensors responding to different<br />
wavelengths in order to discriminate between<br />
flames and spurious sources of radiation.<br />
Intelligent Base Mounted UV IR² 55000-023<br />
Flame Detector<br />
Base Mounted Flame Detector Bracket 29600-458<br />
Intelligent Base Mounted IR³ Flame<br />
Detector<br />
The Intelligent Base Mounted IR³ Flame Detector<br />
is designed to protect areas where open flaming<br />
fires may be expected. The detector has three IR<br />
sensors that respond to different IR wavelengths<br />
in order to discriminate between flames and<br />
spurious sources of radiation.<br />
Intelligent Base Mounted IR³ 55000-024<br />
Flame Detector<br />
Base Mounted Flame Detector Bracket 29600-458<br />
Ancillary products:<br />
Specialist Detectors 47<br />
FLAME DETECTORS<br />
• Responds to stationary flames with no flicker<br />
• Sensitive to UV radiation emitted by flames<br />
during combustion<br />
• Compact flame detector which can fit into<br />
Discovery or XP95 bases<br />
• Loop-powered<br />
• Responds to stationary flames with no flicker<br />
• Sensitive to UV and low-frequency flickering IR<br />
radiation emitted by flames during combustion<br />
• Compact flame detector which can fit into<br />
Discovery or XP95 bases<br />
• Loop-powered<br />
• False alarms due to electrical discharges from<br />
lightning or arc welding and flickering sunlight<br />
are minimised<br />
• Responds to stationary flames with no flicker<br />
• Sensitive to low-frequency flickering<br />
IR radiation emitted by flames during<br />
combustion.<br />
• Compact flame detector which can fit into<br />
Discovery or XP95 bases<br />
• Loop-powered<br />
• False alarms due to factors such as flickering<br />
sunlight are avoided by a combination of filters<br />
and signal processing techniques.<br />
Product Name Part Number Page No.<br />
Flame Sensor Test Unit and Case 29600-226 117<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.
48<br />
Specialist Detectors<br />
BEAM DETECTORS<br />
Beam<br />
Detectors<br />
specialist detectors<br />
Beam detectors are designed to<br />
protect large open spaces such as atria,<br />
museums, churches and warehouses.
Optical Beam Detector<br />
The conventional beam detector is made up of<br />
three parts: the transmitter, which projects a beam<br />
of infra-red light, the receiver, which registers<br />
the light and produces an electric signal, and the<br />
interface, which processes the signal and generates<br />
alarm or fault signals.<br />
Optical Beam Detector 29600-242<br />
Intelligent Reflective Beam Detector<br />
The Intelligent Reflective Beam Detector differs<br />
from a traditional beam detector in that it is a single<br />
unit which houses a transmitter, a receiver and the<br />
control electronics. The beam detector is available in<br />
two versions: a single reflector model for distances<br />
of 5-50m and a four-reflector unit for distances of<br />
50-100m.<br />
Intelligent Reflective Beam 55000-268<br />
Detector 5-50m<br />
Intelligent Reflective Beam 55000-273<br />
Detector 50-100m<br />
Reflective Beam Detector Backbox<br />
The Reflective Beam Detector Backbox allows easy<br />
first fixing of the cabling and terminations to the<br />
Intelligent Reflective Beam Detector (55000-268 &<br />
58000-273). The backbox can be surface or flush<br />
mounted.<br />
Reflective Beam Detector Backbox 29600-241<br />
<strong>Fire</strong>beam ®<br />
<strong>Fire</strong>beam is a reflective beam smoke detector<br />
which is designed to protect large open spaces. It<br />
incorporates a motorised head that can align itself<br />
during commissioning.<br />
<strong>Fire</strong>beam Reflective Beam<br />
Detector 5-40m<br />
29600-350<br />
<strong>Fire</strong>beam Extension Kit 40-80m 29600-351<br />
<strong>Fire</strong>beam Extension Kit 80-100m 29600-352<br />
<strong>Fire</strong>beam Adaptor Plate 29600-353<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
<strong>Fire</strong>beam ® is a registered trade mark of The <strong>Fire</strong> Beam Company<br />
Specialist Detectors 49<br />
BEAM DETECTORS<br />
• Three selectable sensitivity levels<br />
• Drift compensation<br />
• Remote low interface<br />
• Simple wiring and alignment<br />
• Use XP95 Switch Monitor (55000-843) to<br />
interface it to an addressable loop.<br />
• Loop-powered<br />
• Compatible with Discovery and XP95 protocols<br />
• Incorporates a short-circuit isolator<br />
• Automatic drift compensation<br />
• Automatic reset following alarm or fault<br />
condition<br />
• Aesthetically pleasing<br />
• Continually corrects itself against building<br />
movement<br />
• Controlled and adjusted from ground level
50<br />
Specialist Detectors<br />
DUCT DETECTORS<br />
Duct<br />
Detectors<br />
specialist detectors
Intelligent Duct Smoke Detector<br />
The Intelligent Duct Smoke Detector provides early<br />
<strong>detection</strong> of smoke in the air moving through<br />
heating and ventilation (HVAC) ducts in commercial<br />
and industrial premises. Its purpose is to prevent the<br />
re-circulation of smoke from an area on fire to areas<br />
unaffected by the fire.<br />
Intelligent Duct Smoke Detector 53546-022<br />
Conventional Duct Smoke Detector<br />
The Conventional Duct Smoke Detector provides<br />
early <strong>detection</strong> of smoke in the air moving through<br />
heating and ventilation (HVAC) ducts in commercial<br />
and industrial premises. Its purpose is to prevent the<br />
re-circulation of smoke from an area on fire to areas<br />
unaffected by the fire.<br />
Conventional Duct Smoke Detector 53546-021<br />
Orbis Duct Detector<br />
The Orbis Duct Detector provides early <strong>detection</strong><br />
of smoke in the air moving through heating and<br />
ventilation (HVAC) ducts.<br />
Orbis Duct Detector 53546-023<br />
Extension Tubes<br />
Specialist Detectors 51<br />
DUCT DETECTORS<br />
• Operates in air speeds of 0.5m/s to 20m/s<br />
• Transparent cover to view detector head LED<br />
• Integral smoke test port<br />
• For S65 and S60 ranges<br />
• Operates in air speeds of 0.5m/s to 20m/s<br />
• Transparent cover to view detector head LED<br />
• Integral smoke test port<br />
• Designed to accept an Orbis detector head<br />
• Used as supplementary <strong>detection</strong><br />
Product Name Part Number<br />
300-750mm 53541-170<br />
750-1500mm 53541-171<br />
1500-3000mm 53541-172<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.
10 52<br />
Audio Visual Signalling<br />
Audio<br />
Visual<br />
Signalling<br />
Apollo offer a wide range of Audio Visual (AV)<br />
signalling devices – sounders, beacons, sounder<br />
beacons and sounder beacon bases for use in<br />
conjunction with their range of conventional and<br />
intelligent detectors to meet the requirements of<br />
the DDA.
Audio Visual Signalling 53<br />
SOUNDERS<br />
Sounders<br />
audio visual signalling
54<br />
Audio Visual Signalling<br />
SOUNDERS<br />
Intelligent Open-Area Sounder<br />
The Intelligent Open-Area Sounder has been<br />
designed for use in open areas and can be<br />
connected to any Discovery or XP95 system.<br />
Intelligent Open-Area Sounder 55000-001<br />
Red<br />
Intelligent Open-Area Sounder 55000-002<br />
White<br />
Intelligent 100dB(A) Open-Area<br />
Sounder<br />
The 100dB(A) Loop-Powered Sounder is designed<br />
for use in open areas and can be connected to any<br />
Discovery or XP95 system.<br />
Intelligent 100dB(A) Open-Area 55000-278<br />
Sounder Red<br />
Intelligent 100dB(A) Open-Area 55000-279<br />
Sounder White<br />
Intelligent 100dB(A) Open-Area 55000-276<br />
Sounder Slow Whoop Red<br />
Intelligent 100dB(A) Open-Area 55000-277<br />
Sounder Slow Whoop White<br />
Intelligent Weatherproof 100dB(A)<br />
Open-Area Sounder<br />
The 100dB(A) Weatherproof Sounder is designed<br />
for use in open areas and can be connected to any<br />
Discovery or XP95 system. The sounder comprises<br />
a backbox and sounder unit supplied together.<br />
100dB(A) Weatherproof Sounder 55000-274<br />
Red<br />
100dB(A) Weatherproof Sounder 55000-275<br />
White<br />
XPander Sounder and<br />
Sounder Base<br />
The XPander Sounder and Sounder Base is<br />
wireless and designed to be used with XPander<br />
detectors and manual call points only.<br />
XPander Sounder and XPA-CB-14001-APO<br />
Sounder Base Red<br />
XPander Sounder and XPA-CB-14002-APO<br />
Sounder Base White<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
• Self-test fault monitoring<br />
• Choice of tones<br />
• Group addressing and synchronisation of alarm<br />
• Weatherproof IP65<br />
• Comes with Isolating Base as standard<br />
• Loop powered<br />
• Output is 100 dB(A) at 90º<br />
• Ceiling Mounted<br />
• Output is 100dB(A) at 90°<br />
• Current consumption of 5.0mA<br />
• Can be synchronised<br />
• Group address facility<br />
• Loop powered<br />
• Wall mounted<br />
• IP 66 (immune to the affects of wind and<br />
precipitation)<br />
• Output is 100dB(A) at 90°<br />
• Current consumption of 5.0mA<br />
• Can be synchronised<br />
• Group address facility<br />
• Loop powered<br />
• Wall mounted<br />
• Wall mounted<br />
• Wireless<br />
• Eliminates cable problems<br />
• Output is between 92 and 106db(A) at 1m -<br />
dependent on tone setting
Audio Visual Signalling 55<br />
BASE SOUNDERS<br />
Base<br />
Sounders<br />
audio visual signalling
56<br />
Audio Visual Signalling<br />
BASE SOUNDERS<br />
Integrated Base Sounder<br />
The Integrated Base Sounder comprises a base<br />
sounder with integral mounting base and is for<br />
use with Discovery or XP95 ranges. It is designed<br />
for use in enclosed areas.<br />
Integrated Base Sounder † 45681-278<br />
Integrated Base Sounder<br />
with Isolator †<br />
45681-277<br />
Integrated Base Sounder<br />
Slow Whoop †<br />
45681-291<br />
Integrated Base Sounder<br />
Slow Whoop with Isolator †<br />
45681-290<br />
Integrated Base Sounder<br />
DIN-Tone with Isolator<br />
45681-300<br />
Red Cap* 45681-293<br />
White Cap* 45681-292<br />
Intelligent Base Sounder<br />
The Intelligent Base Sounder is for use with<br />
Discovery or XP95 ranges. It is a loop-powered<br />
sounder used to signal a fire alarm in enclosed<br />
areas. A Discovery or XP95 Mounting Base must<br />
be fitted to the Base Sounder, if a detector is to be<br />
fitted.<br />
Intelligent Base Sounder 45681-265<br />
Intelligent Base Sounder, for use<br />
with Isolating Base<br />
45681-266<br />
Intelligent Base Sounder<br />
Slow Whoop<br />
45681-267<br />
Intelligent Base Sounder Slow<br />
Whoop, for use with Isolating Base<br />
45681-268<br />
Red Cap* 29600-257<br />
White Cap* 29600-256<br />
Ancillary Base Sounder<br />
The Ancillary Base Sounder is a local-area sounder<br />
designed for indoor use. It can be connected only<br />
to <strong>detection</strong> systems using Discovery or XP95<br />
detectors and control panels with appropriate<br />
software.<br />
Ancillary Base Sounder 45681-276<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
† Does not have VdS approval<br />
* Does not have CPD or VdS approval<br />
• Two tone ranges<br />
• Synchronisation of ‘alert’ and ‘evacuate’ tones<br />
• Individual and group addressing<br />
• Unique acoustic self-test<br />
• Integrated base<br />
• Isolator option<br />
• Synchronisation of continuous and pulsed<br />
tones<br />
• Multiple address allocation via master/slave<br />
configuration<br />
• Loop powered<br />
• Choice of two output levels<br />
• Guaranteed sound output of 85dB(A) at 1<br />
metre<br />
• Current consumption of only 3mA<br />
• Loop powered<br />
• Responds to signals from the associated<br />
detector - does not have an address of its own<br />
• Adjustable volume control
Series 65 Sounder Base<br />
The Series 65 Sounder Base is a high-efficiency<br />
conventional alarm sounder incorporating a base<br />
for the Series 65 range of detectors. It is designed<br />
so that separate detector and sounder circuits can<br />
be connected. The sounder base can be secured<br />
to a conduit box or surface mounted.<br />
Series 65 Sounder Base 45681-512<br />
Series 65 Sounder Base with diode 45681-513<br />
AlarmSense Sounder Base<br />
The AlarmSense Sounder Base can only be<br />
used with AlarmSense detectors. It is fitted with<br />
electronic circuitry to monitor the presence of<br />
detectors and signals any unauthorised removal<br />
of detector heads. It is supplied with a high or low<br />
volume setting and red or white caps are available<br />
for stand-alone installation<br />
AlarmSense Sounder Base LR 45681-341<br />
AlarmSense Sounder Base 45681-510<br />
Red Cap 45681-295<br />
White Cap 45681-294<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
Audio Visual Signalling 57<br />
BASE SOUNDERS<br />
• 32 tones as standard<br />
• Provides <strong>detection</strong> and alarm signal at one<br />
point<br />
• Diode option<br />
• Detects the removal of a detector head and<br />
reports a fault<br />
• Continues to work during unauthorised<br />
removal of detectors<br />
• Quick and simple installation<br />
• Provides audible signal and <strong>detection</strong> at<br />
one point<br />
• High and low volume ranges
58<br />
Audio Visual Signalling<br />
BEACONS<br />
Beacons<br />
audio visual signalling
Intelligent Open-Area Beacon<br />
The Intelligent Open-Area Beacon has been<br />
developed for use in situations where there is a risk<br />
that sounders will not be heard. It is weatherproof<br />
and can be used outside.<br />
Intelligent Open-Area Beacon 55000-009<br />
Red Lens<br />
Intelligent Open-Area Beacon 55000-010<br />
Clear Lens<br />
Loop-Powered Beacon<br />
The Loop-Powered Beacon is a local-area beacon<br />
designed for indoor use. The beacon has been<br />
developed as a supplement to sounders for use in<br />
situations where there is a risk that sounders will<br />
not be heard.<br />
Loop-Powered Beacon Red 55000-877<br />
Loop Powered Beacon Amber<br />
Loop Powered Beacon<br />
55000-879<br />
Clear Lens/Red Flash 55000-878<br />
Beacon Enclosure<br />
The Beacon Enclosure is weatherproof and allows<br />
Apollo’s loop-powered beacon to be used in highmoisture<br />
environments such as swimming pools<br />
and food processing areas where wash-down<br />
occurs. The enclosure is supplied with a mounting<br />
bracket to accept a Discovery or XP95 base.<br />
Beacon Enclosure 29600-318<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
Audio Visual Signalling 59<br />
• Self-test fault monitoring<br />
• Weatherproof IP65<br />
• Group addressing<br />
• Synchronisation of alarm<br />
• Comes with Isolating Base as standard<br />
• Loop powered<br />
• High intensity LEDs<br />
• More reliable than xenon beacons<br />
• Automatic LED check<br />
• Lockable<br />
• Wide angle of visibility<br />
• Enables DDA compliance<br />
• Synchronised flash<br />
• Can be used with Discovery or XP95<br />
• Protects against water ingress<br />
• Allows beacon to be used outdoors<br />
• Accepts MiniDisc Remote Indicator<br />
• IP67<br />
BEACONS
60<br />
Audio Visual Signalling<br />
BEACON BASES<br />
Beacon<br />
Bases<br />
audio visual signalling
Loop-Powered Beacon Base<br />
The Beacon Base is a loop-powered beacon<br />
combined with a standard Intelligent Mounting<br />
Base. It is used to signal a fire alarm in enclosed<br />
areas. The beacon base can be used with either a<br />
detector fitted or with a cap as a stand-alone alarm<br />
device.<br />
Loop-Powered Beacon Base<br />
with Isolator<br />
45681-333<br />
Loop-Powered Beacon Base<br />
with Standard Flash<br />
45681-335<br />
Loop-Powered Beacon Base<br />
with Australian Flash<br />
45681-337<br />
White Cap 45681-292<br />
Red Cap 45681-293<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
Audio Visual Signalling 61<br />
BEACON BASES<br />
• Beacon flash rate of once per second<br />
• Synchronisation of beacon flash<br />
• Individual and group addressing<br />
• Unique beacon self-test<br />
• Loop powered<br />
• Isolator option
62<br />
Audio Visual Signalling<br />
SOUNDER BEACONS<br />
Sounder<br />
Beacons<br />
audio visual signalling
Intelligent Open-Area Sounder Beacon<br />
The Intelligent Open-Area Sounder Beacon<br />
is designed for use in open areas and can be<br />
connected to an Apollo intelligent system.<br />
Intelligent Open-Area Sounder 55000-005<br />
Beacon Red Lens<br />
Intelligent Open-Area Sounder 55000-006<br />
Beacon Clear Lens<br />
Multi-Tone Open-Area Sounder Beacon<br />
The Multi-Tone Open-Area Sounder Beacon is<br />
designed for use in indoor open areas and can be<br />
connected to any Discovery or XP95 system. The<br />
sounder beacon complements Apollo’s intelligent<br />
and integrated base sounders as well as the loop<br />
powered 100dB(A) sounder.<br />
Multi-Tone Open Area Sounder 55000-293<br />
Beacon Red with Isolator †<br />
Multi-Tone Open Area Sounder 55000-294<br />
Beacon White with Isolator †<br />
Multi-Tone Open Area Sounder 55000-291<br />
Beacon Red<br />
Multi-Tone Open Area Sounder 55000-292<br />
Beacon White †<br />
Weatherproof Multi-Tone Open Area<br />
Sounder Beacon<br />
The Weatherproof Multi-Tone Open Area Sounder<br />
Beacon is designed for use in outdoor open<br />
areas and can be connected to any Discovery or<br />
XP95 system. The sounder beacon complements<br />
Apollo’s intelligent and integrated base sounders<br />
as well as the loop powered 100dB(A) sounder.<br />
Weatherproof Multi-Tone Open Area 55000-298<br />
Sounder Beacon Red with Isolator<br />
Weatherproof Multi-Tone Open Area 55000-299<br />
Sounder Beacon White with Isolator<br />
Weatherproof Multi-Tone Open Area 55000-296<br />
Sounder Beacon Red<br />
Weatherproof Multi-Tone Open Area 55000-297<br />
Sounder Beacon White<br />
XPander Sounder Beacon and<br />
Sounder Base<br />
The XPander Sounder Beacon and Sounder Base<br />
is wireless and designed to be used with XPander<br />
detectors and manual call points only.<br />
XPander Red Sounder XPA-CB-14003-APO<br />
Beacon and Red Sounder Base<br />
XPander Amber Sounder XPA-CB-14004-APO<br />
Beacon and White Sounder Base<br />
XPander Clear Sounder XPA-CB-14005-APO<br />
Beacon and White Sounder Base<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
† Does not have CPD approval<br />
Audio Visual Signalling 63<br />
SOUNDER BEACONS<br />
• IP65 weatherproof<br />
• Gives two functions at one point<br />
• Self-test fault monitoring<br />
• Choice of tones<br />
• Group addressing and synchronisation of alarm<br />
• Comes with Isolating Base as standard<br />
• Loop powered<br />
• Powerful LED combined with 100dB(A) sound<br />
output<br />
• Two volume settings<br />
• Synchronisation of ‘alert’ and ‘evacuate’ tones<br />
• Individual and group addressing<br />
• Three tone choices<br />
• Enables DDA compliance<br />
• Isolator option<br />
• IP66 (immune to the affects of wind and<br />
precipitation)<br />
• Powerful LEDs combined with 100dB(A) sound<br />
output<br />
• Two volume settings<br />
• Synchronisation of ‘alert’ and ‘evacuate’ tones<br />
• Individual and group addressing<br />
• Three tone choices<br />
• Enables DDA compliance<br />
• Isolator option<br />
• Wireless<br />
• Eliminates cable problems<br />
• Enables DDA compliance
64<br />
Audio Visual Signalling<br />
SOUNDER BEACON BASES<br />
Sounder<br />
Beacon<br />
Bases<br />
audio visual signalling
Sounder Beacon Base<br />
The Sounder Beacon Base is a loop-powered<br />
sounder and beacon combined with a standard<br />
Intelligent Mounting Base. It is used to signal a<br />
fire alarm in enclosed areas. The Sounder Beacon<br />
Base can be used either with a detector fitted or<br />
with a cap for operation as a stand-alone alarm<br />
device.<br />
Sounder Beacon Base with Isolator † 45681-330<br />
Sounder Beacon Base † 45681-331<br />
Sounder Beacon Base 45681-336<br />
with Australian Tone †<br />
Sounder Beacon Base with NZ Tone † 45681-338<br />
Sounder Beacon Base Slow Whoop 45681-332<br />
with Isolator †<br />
Sounder Beacon Base 45681-334<br />
with Isolator DIN-Tone<br />
White Cap †‡ 45681-292<br />
Red Cap †‡ 45681-293<br />
AlarmSense Sounder Beacon Base<br />
The AlarmSense Sounder Beacon Base is designed<br />
to be used with AlarmSense detectors only.<br />
AlarmSense Sounder Beacon Base LR 45681-340<br />
AlarmSense Sounder Beacon Base 45681-509<br />
Red Cap 45681-295<br />
White Cap 45681-294<br />
Discovery Sounder<br />
Beacon Base<br />
The Discovery Sounder Beacon Base makes<br />
full use of the Discovery protocol. For ease of<br />
commissioning a ‘magnetic wand’ can be used to<br />
test and adjust each sounder locally.<br />
Discovery Sounder Beacon Base 45681-393<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
† Does not have VdS approval<br />
‡ Does not have CPD approval<br />
Audio Visual Signalling 65<br />
SOUNDER BEACON BASES<br />
• Two volume ranges 55-75dB(A) and<br />
75-91dB(A)<br />
• Beacon flash rate of once per second<br />
• Synchronisation of ‘alert’ and ‘evacuate’ tones<br />
• Synchronisation of beacon flash<br />
• Individual and group addressing<br />
• Unique acoustic and beacon self test<br />
• Enables DDA compliance<br />
• Sounder range between 70dB(A) and 87dB(A)<br />
• Detects the removal of a detector head and<br />
reports a fault<br />
• Continues to work during unauthorised<br />
removal of detectors<br />
• Quick and simple installation<br />
• It is possible to set individual control of the<br />
sounder and beacon<br />
• Volume and tone settings can be selected<br />
from the control panel<br />
• Tones can be used for other purposes in<br />
addition to warning of fire, ideal for schools<br />
• Enables soft start option, ideal for hospitals<br />
and nursing homes<br />
• Electronic bell tone
66<br />
Audio Visual Signalling<br />
AV ACCESSORIES<br />
Audio<br />
Visual<br />
Accessories<br />
audio visual signalling
Beacon Enclosure<br />
The Beacon Enclosure is weatherproof allowing<br />
a loop-powered beacon to be installed outside<br />
and in high moisture environments such as<br />
swimming pools.<br />
Beacon Enclosure 29600-318<br />
Magnetic Wand<br />
The Magnetic Wand is used to initiate and terminate<br />
actions such as adjusting and setting the sound<br />
levels of the Discovery Sounder Beacon Base.<br />
Magnetic Wand 29650-001<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
Audio Visual Signalling 67<br />
• Can be installed outside<br />
• IP 67<br />
AV ACCESSORIES<br />
• Flexibility to set sound output to desired level<br />
during walk test<br />
• Allows local testing of Discovery Sounder<br />
Beacon Bases<br />
• 1.2m when extended
68<br />
Interfaces<br />
Interfaces<br />
Apollo manufactures a comprehensive range of<br />
interfaces for intelligent systems which enable fire<br />
protection systems to be engineered simply and<br />
effectively without the need for custom-designed<br />
<strong>equipment</strong>. There are a variety of interfaces<br />
available to suit a number of individual applications.
Standard Interfaces are fitted with<br />
bi-directional short-circuit isolators so<br />
that they are unaffected by a single<br />
short circuit on either loop input or<br />
output. The exception to this is the<br />
Mains Input/Output unit which is not<br />
isolated.<br />
Key features of Apollo Interfaces:<br />
• Easy to install<br />
• Well protected<br />
• Modular design<br />
• A neat solution<br />
Interfaces 69<br />
STANDARD INTERFACES<br />
Standard<br />
Interfaces
70<br />
Interfaces<br />
STANDARD INTERFACES<br />
Input/Output Unit<br />
The Input/Output unit provides a voltage<br />
free, double pole change-over (DPCO) relay<br />
output, a single monitored switch input and an<br />
unmonitored, non-polarised opto-coupled input.<br />
Input/Output Unit 55000-847<br />
Three Channel Input/Output Unit<br />
The Three Channel Input/Output Unit provides<br />
three voltage-free, single pole, change-over relay<br />
outputs and three monitored switch inputs.<br />
Three Channel Input/Output Unit 55000-588<br />
Output Unit<br />
The Output Unit provides a voltage-free single<br />
pole, change-over relay output. It is a simplified<br />
version of the Input/Output unit without circuitry<br />
for monitoring inputs.<br />
Output Unit 55000-849<br />
Sounder Control Unit<br />
The Sounder Control Unit is used to control the<br />
operation of a zone of conventional sounders and<br />
report their status to the control panel.<br />
Sounder Control Unit 55000-852<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
• It can report fault, switch open and switch<br />
closed levels<br />
• Three visible LEDs<br />
• Loop powered<br />
• Voltage free<br />
• Capable of switching up to 30V at 1A<br />
• Supervises one or more normally-open<br />
switches on each of the three inputs<br />
• Loop powered<br />
• Capable of switching up to 30V at 1A on each<br />
of the three outputs<br />
• Capable of switching up to 30V at 1A<br />
• Allows sounders to be operated continuously<br />
or be pulsed, 1 second on, 1 second off<br />
• May be synchronised when in pulsed operation
Switch Monitor<br />
The Switch Monitor is designed to monitor the<br />
state of one or more single pole, volt free contacts<br />
connected on a single pair of cables and to report<br />
the status to Apollo compatible analogue control<br />
<strong>equipment</strong>.<br />
Switch Monitor 55000-843<br />
Switch Monitor Plus<br />
The Switch Monitor Plus is designed to monitor<br />
the state of one or more single pole, volt free<br />
contacts connected on a single pair of cables and<br />
to report the status to Apollo compatible analogue<br />
control <strong>equipment</strong>.<br />
Switch Monitor Plus 55000-841<br />
Zone Monitor<br />
The Zone Monitor powers and controls the<br />
operation of a zone of up to 20 Apollo Series 65<br />
or Orbis fire detectors from a Discovery or XP95<br />
Loop.<br />
Zone Monitor 55000-845<br />
Mains Switching Input/Output Unit*<br />
The Mains Switching Input/Output Unit provides a<br />
voltage-free, single pole change-over relay output<br />
and a monitored switch input.<br />
Mains Switching Input/Output Unit 55000-875<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
*Not isolated<br />
Interfaces 71<br />
STANDARD INTERFACES<br />
• Four input states - ’normal’, ’fault’,<br />
’pre-alarm’ and ’alarm’<br />
• Two visible LEDs<br />
• Loop powered<br />
• Output for resetting a remote detector<br />
• Four input states - ’normal’, ’fault’,<br />
’pre-alarm’ and ’alarm’<br />
• Two visible LEDs<br />
• Selectable alarm delay for monitoring<br />
flow switches<br />
• Loop powered<br />
• Visible LED<br />
• Supervises one or more normally-open<br />
switches connected to a single pair of cables<br />
• Three visible LEDs<br />
• Capable of switching 250V AC at up to 5A
72<br />
Interfaces<br />
STANDARD INTERFACES<br />
With the exception of the Mains Switching Input/Output Unit Apollo’s range of standard interfaces<br />
without Isolators has been discontinued. The alternatives are listed below.<br />
Comparison chart<br />
Product Name Part Number<br />
Without Isolator With Isolator<br />
Input/Output Unit 55000-818 55000-847<br />
Three Channel Input/Output Unit 55000-589 55000-588<br />
Output Unit 55000-819 55000-849<br />
Sounder Control Unit 55000-823 55000-852<br />
Switch Monitor 55000-810 55000-843<br />
Switch Monitor Plus 55000-809 55000-841<br />
Zone Monitor 55000-813 55000-845<br />
Mains Switching I/O Unit 55000-875 N/A<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.
Mini Interfaces use very compact<br />
enclosures for installation into other<br />
<strong>equipment</strong>.<br />
Interfaces 73<br />
MINI INTERFACES<br />
Mini<br />
Interfaces
74<br />
Interfaces<br />
MINI INTERFACES<br />
Mini Switch Monitor<br />
The New Mini Switch Monitor is an interface<br />
within an entirely new housing. This allows the<br />
unit to be fitted onto a standard 35mm DIN-Rail<br />
(using a twist-click motion) or mounted within<br />
an enclosure, for example a manual call point. It is<br />
designed to monitor the state of one or more single<br />
pole, volt free contacts connected on a single<br />
pair of cables and to report the status to Apollo<br />
compatible analogue control <strong>equipment</strong>.<br />
Mini Switch Monitor 55000-760<br />
Mini Switch Monitor with fly leads<br />
The Mini Switch Monitor is designed to monitor<br />
the state of one or more single pole, volt free<br />
contacts connected on a single pair<br />
of cables and to report the status to Apollo<br />
compatible analogue control <strong>equipment</strong>.<br />
Mini Switch Monitor 55000-833<br />
Mini Switch Monitor with fly leads<br />
(Interrupt)<br />
The Mini Switch Monitor (Interrupt) is designed to<br />
monitor the state of one or more single pole, volt<br />
free contacts connected on a single pair of cables<br />
and to report the status to Apollo compatible<br />
analogue control <strong>equipment</strong>. It can also place<br />
a current pulse in the ‘interrupt’ bit to signal the<br />
operation of a manual call point.<br />
Mini Switch Monitor (Interrupt) 55000-832<br />
*Please check the Apollo website for up-to-date approvals information.<br />
• Designed for use where space is limited<br />
• Isolated as standard<br />
• Interrupt/non interrupt in one unit<br />
• ‘Pre-alarm’ status available<br />
• Three, coloured LEDs, giving clear status<br />
indication<br />
• Four input states - ’normal’, ’fault’,<br />
’pre-alarm’ and ’alarm’<br />
• Visible LED with remote LED connection option<br />
• Loop powered<br />
• Designed for use where space is limited<br />
• Easy to install<br />
• Three input states - ’normal’, ’fault’ and ’alarm’<br />
• Visible LED with remote LED connection option<br />
• Loop powered<br />
• Designed for use where space is limited<br />
• Easy to install<br />
• Monitors <strong>equipment</strong> where a fast response<br />
is required<br />
• Interrupt facility
Interfaces 75<br />
DIN-RAIL INTERFACES<br />
DIN-Rail Interfaces feature enclosures<br />
that clip to standard 35mm DIN-Rails<br />
or are screwed to the base of a larger<br />
enclosure. They enable fire system<br />
designers to determine the functions<br />
required and create multi-purpose<br />
DIN-Rail<br />
interfaces for individual sites.<br />
Interfaces
76<br />
Interfaces<br />
DIN-RAIL INTERFACES<br />
DIN-Rail Input/Output Unit<br />
The DIN-Rail Input/Output Unit provides a<br />
voltage free, single pole, change-over relay<br />
output, a single, monitored switch input and an<br />
unmonitored, non-polarised opto-coupled input.<br />
DIN-Rail Input/Output Unit 55000-803<br />
DIN-Rail Output Unit<br />
The DIN-Rail Output Unit provides a voltagefree<br />
single pole, change-over relay output. It is a<br />
simplified version of the Input/Output unit without<br />
circuitry for monitoring inputs.<br />
DIN-Rail Output Unit 55000-804<br />
DIN-Rail Switch Monitor<br />
The DIN-Rail Switch Monitor is designed to<br />
monitor the state of one or more single pole, volt<br />
free contacts connected on a single pair of cables<br />
and to report the status to Apollo compatible<br />
analogue control <strong>equipment</strong>.<br />
DIN-Rail Switch Monitor 55000-822<br />
NEW!! DIN-Rail Mains Input/Output Unit<br />
The DIN-Rail Mains Input/Output Unit provides a<br />
voltage-free, single pole change-over relay output<br />
and a monitored switch input. The Unit supervises<br />
one or more normally-open switches connected<br />
to a single pair of cables.<br />
DIN-Rail Mains Input/Output Unit 55000-797<br />
NEW!! DIN-Rail Sounder Controller<br />
(5 Amperes)<br />
The DIN-Rail Sounder Controller (5 Amperes)<br />
is used to control the operation of a zone of<br />
externally powered sounders and report their<br />
status to the control panel.<br />
DIN-Rail Sounder Controller (5 Amp) 55000-182<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
• It can report fault, switch open and switch<br />
closed levels<br />
• Three visible LEDs<br />
• Loop powered<br />
• Voltage free<br />
• Capable of switching up to 30V at 1A<br />
• Capable of switching up to 30V at 1A<br />
• Four input states - ’normal’, ’fault’,<br />
’pre-alarm’ and ’alarm’<br />
• Two visible LEDs<br />
• Loop powered<br />
• It can report fault, switch open and switch<br />
closed levels<br />
• Three visible LEDs<br />
• Capable of switching up to 8A at 240V AC<br />
• Fits a standard 35mm DIN-Rail<br />
• Allows sounders to be operated continuously<br />
or be pulsed, 1 second on, 1 second off<br />
• May be synchronised when in pulsed<br />
operation<br />
• An opto-coupled input is provided to monitor<br />
the state of the external power supply.<br />
• Sounders can be operated individually or in<br />
groups<br />
• Will accept a load of 5 amperes
DIN-Rail Switch Monitor Plus<br />
The DIN-Rail Switch Monitor Plus is designed to<br />
monitor the state of one or more single pole, volt<br />
free contacts connected on a single pair of cables<br />
and to report the status to Apollo compatible<br />
analogue control <strong>equipment</strong>.<br />
DIN-Rail Switch Monitor Plus 55000-821<br />
DIN-Rail Zone Monitor<br />
with Isolator<br />
The Zone Monitor powers and controls the<br />
operation of a zone of up to 20 Apollo Series 65 or<br />
Orbis fire detectors from a Discovery or XP95 Loop.<br />
DIN-Rail Zone Monitor with Isolator 55000-812<br />
DIN-Rail Dual Isolator<br />
The DIN-Rail Dual Isolator provides two<br />
independent Isolators which sense and isolate<br />
short circuits on Discovery or XP95 loops<br />
and spurs.<br />
DIN-Rail Dual Isolator 55000-802<br />
Mini Switch Monitor<br />
The Mini Switch Monitor is an interface within<br />
an entirely new housing. This allows the unit to<br />
be fitted onto a standard 35mm DIN-Rail (using<br />
a twist-click motion) or mounted within an<br />
enclosure, for example a manual call point. It is<br />
designed to monitor the state of one or more single<br />
pole, volt free contacts connected on a single<br />
pair of cables and to report the status to Apollo<br />
compatible analogue control <strong>equipment</strong>.<br />
Mini Switch Monitor 55000-760<br />
DIN-Rail Accessories:<br />
Interfaces 77<br />
DIN-RAIL INTERFACES<br />
• Output for resetting a remote detector<br />
• Four input states - ’normal’, ’fault’,<br />
’pre-alarm’ and ’alarm’<br />
• Two visible LEDs<br />
• Loop powered<br />
• Selectable alarm delay for monitoring<br />
flow switches<br />
• Loop powered<br />
• Visible short circuit LED<br />
• Built in Isolator<br />
• Loop powered<br />
• Polarity sensitive<br />
• Up to 20 detectors can be installed between<br />
isolators<br />
• Allows fully isolated spurs<br />
• Designed for use where space is limited<br />
• Isolated as standard<br />
• Interrupt/non interrupt in one unit<br />
• ‘Pre-alarm’ status available<br />
• Three, coloured LEDs, giving clear status<br />
indication<br />
Product Name Part Number Page No.<br />
DIN-Rail Interface Enclosure (4 units) 29600-239 85<br />
DIN-Rail Interface Enclosure (10 units) 29600-240 85<br />
DIN-Rail End Stops 27447-528<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.
78<br />
Manual Call Points<br />
Manual<br />
Call Points
Discovery Manual Call Point<br />
The Discovery Manual Call Point is compliant<br />
with EN54-11. The Call Point can be addressed<br />
at the commissioning stage by means of a<br />
seven-segment DIL switch. When operated, the<br />
manual call point interrupts the polling cycle for<br />
a fast response.<br />
Discovery Manual Call Point 58100-910<br />
(Surface)<br />
Discovery Manual Call Point 58100-908<br />
with Isolator (Surface)<br />
Discovery Manual Call Point<br />
(non-standard)<br />
In addition to the standard Discovery Manual<br />
Call Point, Apollo offer a selection of differently<br />
coloured call points, suitable for a variety of<br />
different applications.<br />
Discovery Manual Call Point 58100-926<br />
(Non Standard) White (Surface)<br />
Discovery Manual Call Point 58100-927<br />
(Non Standard) Yellow (Surface)<br />
Discovery Manual Call Point 58100-928<br />
(Non Standard) Blue (Surface)<br />
Discovery Manual Call Point 58100-929<br />
(Non Standard) Green (Surface)<br />
XP95 Manual Call Point<br />
The XP95 Manual Call Point is compliant with<br />
EN54-11. The address of each call point is set at the<br />
commissioning stage by means of a seven-segment<br />
DIL switch. The device features plug and play terminal<br />
connections and a resettable element.<br />
XP95 Manual Call Point 55100-905<br />
(Surface)<br />
XP95 Manual Call Point 55100-908<br />
with Isolator (Surface)<br />
Transparent Hinged Cover<br />
The Transparent Hinged Cover is for use with<br />
XP95 and Discovery Manual Call Points and can<br />
be fitted to add further protection against<br />
accidental operation.<br />
Transparent Hinged Cover 26729-152<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
Manual Call Points 79<br />
MANUAL CALL POINTS<br />
• Flashing LED option<br />
• Plug and play terminal connections for<br />
fast wiring<br />
• Allow wiring continuity testing before fitting<br />
• Reports an alarm in under 0.2 seconds<br />
• Resettable element<br />
• Flashing LED option<br />
• Plug and play terminal connections for<br />
fast wiring<br />
• Allow wiring continuity testing before fitting<br />
• Reports an alarm in under 0.2 seconds<br />
• Resettable element<br />
• Plug and play terminal connections for<br />
fast wiring<br />
• Allow wiring continuity testing before fitting<br />
• Reports an alarm in under 0.2 seconds<br />
• Resettable element<br />
• Locking tag<br />
• Reduces risk of vandalism<br />
* Please note - the manual call point does not comply<br />
with EN54 when fitted with this cover.
80<br />
Manual Call Points<br />
MANUAL CALL POINTS<br />
Waterproof Manual Call Point<br />
The Waterproof Manual Call Point has been<br />
designed for use outdoors and in places where<br />
moisture can occur. It is compliant with EN54-11<br />
and can be used with the XP95 and Discovery<br />
ranges.<br />
Waterproof Manual Call Point 58100-950<br />
Waterproof Manual Call Point 58100-951<br />
with Isolator<br />
Waterproof Manual Call Point 58100-953<br />
with Isolator (Yellow)†<br />
AlarmSense Manual Call Point<br />
The AlarmSense Manual Call Point is compliant<br />
with EN54:11. It is different from other<br />
conventional call points in that it can be detected<br />
as an operated call point rather than a detector<br />
that has changed to the alarm state.<br />
AlarmSense Manual Call Point 55100-894<br />
(Surface)<br />
XPander Manual Call Point<br />
The XPander Manual Call Point is compliant with<br />
EN54:11. It is wireless and is powered by two<br />
independent packs of 3 AA alkaline batteries<br />
with a typical three year life.<br />
XPander Manual Call Point XPA-MC-14006-APO<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
† Does not have CPD approval<br />
• Plug and play terminal connections for fast<br />
wiring<br />
• Allow wiring continuity testing before fitting<br />
• Resettable element<br />
• IP 67<br />
• Gives immediate response<br />
• Unique identification signalling<br />
• Resettable element<br />
• Uses patented XPERT addressing<br />
• Resettable element<br />
• Reports an alarm in under one second
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
Manual Call Points 81<br />
MANUAL CALL POINTS
82<br />
Mounting Accessories<br />
Mounting<br />
Accessories
Backplate<br />
The Backplate provides a high degree of<br />
protection against the ingress of water or dust<br />
into the back of the detector mounted directly<br />
onto a mounting box. When the backplate is used<br />
with an XP95 device, the number tab of the XPERT<br />
card must be snapped off and placed in one of the<br />
knockout slots provided in the backplate.<br />
Backplate 45681-233<br />
Base Cover<br />
Base Covers are available as part of the Series 65<br />
and XP95 ranges.<br />
Series 65 Base Cover 45681-370<br />
XP95 Base Cover 45681-380<br />
Conduit Box<br />
The Conduit Box is a versatile accessory for<br />
surface mounting Apollo bases. The box has<br />
knockouts to accept PG16 or M20 cable glands,<br />
conduit or mini-trunking. Self-tapping screws are<br />
included to fit the detector base to the conduit box.<br />
Conduit Box 45681-204<br />
Sounder Ceiling Plate<br />
The Sounder Ceiling Plate allows surface mounted<br />
cabling to be fitted to a loop powered sounder<br />
base.<br />
Sounder Ceiling Plate 45681-311<br />
Module Base<br />
The Module Base is an accessory which<br />
can be secured to a standard base allowing<br />
customers to fit their own electronics.<br />
Module Base 38531-822<br />
Mounting Accessories 83<br />
• Protects against water ingress<br />
• Improved performance<br />
• Fits Discovery, XP95, Orbis, Series 65 and<br />
AlarmSense bases<br />
• Protects base when detector not in situ<br />
• Aesthetically pleasing<br />
• Easy to install<br />
• Aesthetically pleasing<br />
• Ease of installation<br />
• Ideal for use with concrete ceilings where<br />
drilling is not permissible<br />
• 5mm in depth<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
MOUNTING ACCESSORIES
84<br />
Mounting Accessories<br />
MOUNTING ACCESSORIES<br />
Deckhead Mounting Boxes<br />
The Deckhead Mounting Box gives extra<br />
protection to devices to be fitted in areas where<br />
there is the possibility of moisture or condensation<br />
ingressing through the rear of the of the base.<br />
The new version is suitable for a wider range of<br />
detector bases as well as Apollo’s AV bases.<br />
NEW!! Deckhead Mounting Box 45681-217<br />
Metal Deckhead Mounting Box 29600-131<br />
(has access ports threaded to fit<br />
PG16 glands)<br />
Metal Deckhead Mounting Box 29600-139<br />
(has access ports threaded to fit<br />
M20 components)<br />
Deckhead Adaptor (for use with 27249-005<br />
29600-196 - converts cable glands<br />
from PG16 to M20)<br />
Ceiling Tile Mounting Box<br />
The Ceiling Tile Mounting Box has been designed<br />
to make the installation of detectors and sounders<br />
quick and easy prior to the fitting of a false ceiling.<br />
Detector and sounder bases can be fitted, wired<br />
and, if necessary, tested and commissioned<br />
before the installation of a false ceiling.<br />
Detector Ceiling Tile Mounting Box 45681-309<br />
Sounder Ceiling Tile Mounting Box 45681-310<br />
Beacon Enclosure<br />
The Beacon Enclosure is weatherproof allowing a<br />
loop-powered beacon to be installed outside and<br />
in high moisture environments such as swimming<br />
pools. The enclosure is supplied with a mounting<br />
bracket to accept a Discovery or XP95 base.<br />
Beacon Enclosure 29600-318<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
• Protects against water ingress<br />
• Improved performance<br />
• Available in polycarbonate or metal<br />
• Polycarbonate Deckhead Mounting Box<br />
45681-217 also fits Apollo Audio Visual bases<br />
• No need for separate backbox<br />
• Can be used with tiles up to 25mm thick<br />
• Quick and easy installation<br />
• Protects against water ingress<br />
• Allows beacon to be used outdoors<br />
• Accepts MiniDisc remote indicator<br />
• IP67
DIN-Rail Interface Enclosures<br />
DIN-Rail Interface Enclosures are available in two<br />
sizes and can be used for housing intrinsically safe<br />
(IS) barriers or DIN-rail mounted interfaces. A multipurpose<br />
label that features a section for use with<br />
IS systems is supplied. For non-IS systems, the<br />
part referring to IS can simply be removed.<br />
DIN-Rail Interface Enclosure (4 units) 29600-239<br />
DIN-Rail Interface Enclosure (10 units) 29600-240<br />
1.5mm Hexagonal Driver<br />
The 1.5mm Hexagonal Driver is used to turn the<br />
locking screw fitted to Discovery, XP95 and<br />
Series 65 detectors.<br />
1.5mm Hexagonal Driver 29600-095<br />
Series 90 to XP95 Base Adaptor<br />
The XP95 Base Adaptor is designed to allow XP95<br />
detectors to be fitted to an existing Series 90<br />
base. The adaptor eliminates the need to rewire an<br />
existing Apollo intelligent system.<br />
Series 90 to XP95 Base Adaptor 45681-238<br />
Series 65 to Orbis Base Adaptor<br />
The Orbis Adaptor is designed to allow Orbis<br />
detectors to be fitted to an existing Series 60 or<br />
Series 65 base. The adaptor eliminates the need<br />
to rewire an existing Apollo conventional system.<br />
Series 65 to Orbis Base Adaptor ORB-BA-10008-APO<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
Mounting Accessories 85<br />
MOUNTING ACCESSORIES<br />
• Allows multiple interfaces to be housed<br />
together<br />
• IP67<br />
• Allows detectors to be fitted with ease<br />
• Allows an existing range to be updated<br />
with ease<br />
• Eliminates the need for re-wiring<br />
• Allows an existing range to be updated<br />
with ease<br />
• Eliminates the need for re-wiring
86<br />
Marine<br />
Marine<br />
Apollo offer both conventional and intelligent ranges of<br />
smoke and heat detectors which are approved for use<br />
in the marine environment. These detectors operate in<br />
the same way and carry the same approvals as standard<br />
detectors but are subject to additional approvals tests,<br />
specific to the marine environment.<br />
The marine detectors are approved by the following bodies:<br />
• American Bureau of Shipping<br />
• Bureau Veritas<br />
• China Classification Society<br />
• Det Norske Veritas<br />
• Germanischer Lloyd<br />
• Lloyd’s Register of Shipping<br />
• Maritime and Coastguard Agency<br />
• Marine Marchande Française
Discovery Marine intelligent fire<br />
detectors are suitable for larger<br />
vessels. The high specification range<br />
has been developed to meet the<br />
requirements of sophisticated systems.<br />
Discovery gives you total reassurance<br />
in installations where it is necessary to<br />
adapt <strong>detection</strong> to different operating<br />
environments and where protection<br />
against unwanted alarms is paramount.<br />
Key features of Discovery Marine:<br />
• Approved for use in the marine environment<br />
• Five response modes for environmental adaptation<br />
• Day/Night switching for increased reliability<br />
• Drift compensation for false alarm reduction<br />
• User programmability for data retention<br />
• XPERT card addressing for increased security<br />
Marine 87<br />
DISCOVERY MARINE<br />
Discovery<br />
marine
88<br />
Marine<br />
DISCOVERY MARINE<br />
Discovery Marine<br />
Ionisation Smoke Detector<br />
The Discovery Marine Ionisation Detector uses<br />
a low activity radioactive foil to detect fires by<br />
irradiating the air in the smoke chamber and<br />
causing a current flow. If smoke enters the<br />
chamber, the current flow is reduced leading<br />
to an alarm.<br />
Discovery Marine<br />
Ionisation Smoke Detector 58000-500MAR<br />
Discovery Marine<br />
Optical Smoke Detector<br />
The Discovery Marine Optical Smoke Detector<br />
works using the light scatter principle and is<br />
ideal for applications where slow-burning or<br />
smouldering fires are likely.<br />
Discovery Marine<br />
Optical Smoke Detector 58000-600MAR<br />
Discovery Marine Heat Detector<br />
The Discovery Marine Heat Detector,<br />
distinguishable by the low airflow resistant<br />
case, uses a single thermistor to sense the air<br />
temperature around the detector.<br />
Discovery Marine Heat Detector 58000-400MAR<br />
Discovery Marine Multisensor Detector<br />
The Discovery Marine Multisensor detector<br />
comprises optical smoke and thermistor<br />
temperature sensors whose outputs are combined<br />
to give the final analogue value. As a result,<br />
the multisensor is useful over a wide range of<br />
applications and is highly immune to false alarms.<br />
Discovery Marine<br />
Multisensor Detector 58000-700MAR<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
• Responds well to fast-burning, flaming fires<br />
• Designed to operate in a variety of<br />
environments<br />
• Remote test feature<br />
• Rejection of transient signals<br />
• Responds well to slow-burning, smouldering<br />
fires<br />
• Suitable for bedrooms and escape routes<br />
• Unaffected by wind or atmospheric pressure<br />
• Remote test feature<br />
• Rejection of transient signals<br />
• Ideal in environments that are dirty or smoky<br />
• Unaffected by wind or atmospheric pressure<br />
• Remote test feature<br />
• Rejection of transient signals<br />
• Ideal for a wide range of applications<br />
• Highly immune to false alarms<br />
• Unaffected by wind or atmospheric pressure<br />
• Remote test feature<br />
• Rejection of transient signals
Discovery Marine Mounting Base<br />
All detectors in the Discovery Marine range<br />
are for use with the Marine Mounting Base. The<br />
Mounting Base is a low insertion force base with<br />
stainless steel contacts for the detector terminals.<br />
XPERT cards are supplied with all bases.<br />
Discovery Marine Mounting Base 45681-210MAR<br />
Discovery Marine Manual Call Point<br />
The Discovery Marine Manual Call Point has been<br />
approved for use in indoor marine applications<br />
such as cruise liners. When operated, the manual<br />
call point interrupts the polling cycle for a fast<br />
response.<br />
Discovery Marine Manual 58100-970MAR<br />
Call Point<br />
Discovery Marine Manual 58100-971MAR<br />
Call Point with Isolator<br />
Discovery Marine Isolator<br />
The Discovery Marine Isolator is placed at intervals<br />
on the loop and ensures that, in the case of a short<br />
circuit, only the section between the isolators will<br />
be affected. When the short circuit is removed,<br />
the isolators automatically restore power in the<br />
isolated section.<br />
Discovery Marine Isolator 55000-700MAR<br />
Discovery Marine Isolator Base<br />
The Discovery Marine Isolator Base is unique and<br />
designed to only accept the marine isolator.<br />
Discovery Marine Isolator Base 45681-211MAR<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
Marine 89<br />
DISCOVERY MARINE<br />
• XPERT addressing<br />
• One way fit<br />
• Locking feature to prevent unauthorised<br />
removal<br />
• Reports an alarm in under 0.2 seconds<br />
• Resettable element<br />
• Detects wiring short circuits using patented<br />
technology<br />
• Minimises disruption from short-circuits<br />
• Automatic de-isolation on short-circuit removal<br />
• The equivalent of up to 20 smoke detectors<br />
may be installed between isolators<br />
• Only accepts the Marine Isolator
90<br />
Marine<br />
ORBIS MARINE<br />
Orbis<br />
marine<br />
Orbis Marine conventional fire detectors<br />
offer a wealth of features to save time,<br />
enhance reliability and reduce false<br />
alarms within the marine environment.<br />
These include drift compensation and<br />
DirtAlert ® , a feature that warns service<br />
engineers via a flashing yellow LED<br />
that detectors need maintenance;<br />
and patented FasTest ® , a procedure<br />
that takes just four seconds to test<br />
smoke detectors and confirm that they<br />
are functioning correctly.<br />
Key features of Orbis Marine:<br />
• Approved for use in marine environments<br />
• Modern, low-profile design<br />
• TImeSaver Base ® for fast installation<br />
• Transient rejection for false alarm reduction<br />
• High humidity tolerance at up to 98%RH<br />
• Wide operating temperature -40°C to +70°C
Orbis Marine Optical Smoke Detector<br />
The Orbis Marine Optical Smoke Detector operates<br />
on the well established light scatter principle.<br />
However, the sensing technology is radically<br />
different in design from previous optical detectors<br />
and significantly reduces false alarms.<br />
Orbis Marine Optical Smoke ORB-OP-42001-MAR<br />
Detector<br />
Orbis Marine Optical Smoke ORB-OP-42003-MAR<br />
Detector with flashing LED<br />
Orbis Marine Multisensor Detector<br />
The Orbis Marine Multisensor Detector benefits<br />
from the same false alarm reduction technology<br />
as the optical detector. It is a thermally enhanced<br />
smoke detector and so will not give an alarm<br />
from heat alone.<br />
Orbis Marine Multisensor ORB-OH-43001-MAR<br />
Smoke Detector<br />
Orbis Marine Multisensor ORB-OH-43003-MAR<br />
Smoke Detector with flashing LED<br />
Orbis Marine Heat Detector<br />
The Orbis Marine Heat Detector uses a single<br />
thermistor to sense the air temperature around<br />
the detector. There are twelve heat detectors in<br />
the Orbis Marine range designed to suit a wide<br />
variety of operating conditions.<br />
Orbis Marine Heat Detector<br />
A1R Standard ORB-HT-41001-MAR<br />
A1R with Flashing LED ORB-HT-41013-MAR<br />
A2S Standard ORB-HT-41002-MAR<br />
A2S with Flashing LED ORB-HT-41014-MAR<br />
BR Standard ORB-HT-41003-MAR<br />
BR with Flashing LED ORB-HT-41015-MAR<br />
BS Standard ORB-HT-41004-MAR<br />
BS with Flashing LED ORB-HT-41016-MAR<br />
CR Standard ORB-HT-41005-MAR<br />
CR with Flashing LED ORB-HT-41017-MAR<br />
CS Standard ORB-HT-41006-MAR<br />
CS with Flashing LED ORB-HT-41018-MAR<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
Marine 91<br />
ORBIS MARINE<br />
• Responds well to slow-burning, smouldering<br />
fires<br />
• Performs well in detecting black and white<br />
smoke<br />
• Extra confirmation of smoke before alarm<br />
signal is given<br />
• Reduced incidents of false alarms<br />
• Sensing chamber keeps out dust and other<br />
airborne contaminants<br />
• Operates over a broad voltage range of at<br />
extremes of temperature<br />
• Flashing LED option<br />
• Responds well to fast-burning, flaming fires<br />
• Reduced incidence of false alarms<br />
• Increased reliability of <strong>detection</strong><br />
• Sensing chamber keeps out dust and other<br />
airborne contaminants<br />
• Operates over a broad range of voltages at<br />
extremes of temperature<br />
• Flashing LED option<br />
• Can be used for applications where smoke<br />
detectors are unsuitable<br />
• Ideal for environments that are dirty or smoky<br />
under normal conditions<br />
• Reduced incidences of false alarms<br />
• Increased reliability of <strong>detection</strong><br />
• Flashing LED option
92<br />
Marine<br />
ORBIS MARINE<br />
Orbis Marine TimeSaver Base ®<br />
The Orbis Marine TimeSaver Base® is a<br />
completely new design that provides installers<br />
with an open working area with fixing holes<br />
shaped to allow a simple mounting procedure.<br />
Orbis Marine TimeSaver ORB-MB-00001-MAR<br />
Base ®<br />
Orbis Marine Relay Base<br />
The Orbis Marine Relay Base incorporates a<br />
single-pole voltage-free change over contact for<br />
switching ancillary <strong>equipment</strong>. When the detector<br />
changes to the alarm state, the relay is energised,<br />
causing the contact to change state. The contact<br />
will remain in this condition until the detector is<br />
reset.<br />
Orbis Marine Relay Base ORB-RB-40004-MAR<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
• Grouped terminals to make wiring easy<br />
• Two fixing centres<br />
• LED alignment mark<br />
• Cable stripping guide<br />
• Continuity link for voltage testing of zone<br />
wiring prior to commissioning<br />
• Detector locking mechanism<br />
• Grouped terminals to make wiring easy<br />
• Two fixing centres<br />
• LED alignment mark<br />
• Cable stripping guide<br />
• Continuity link for voltage testing of zone<br />
wiring prior to commissioning<br />
• Detector locking mechanism
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
Marine 93<br />
ORBIS MARINE
94<br />
Intrinsically Safe Detectors<br />
Intrinsically<br />
Safe<br />
Detectors<br />
There are many places where an explosive mixture of air and gas or<br />
vapour is, or may be present continuously, intermittently or as a result of<br />
an accident. These are defined as hazardous areas by BS EN 60079, the<br />
code of practice for installation and maintenance of electrical apparatus<br />
in potentially explosive atmospheres.<br />
Hazardous areas are common in petroleum and chemical engineering<br />
plants and in factories processing and storing gases, solvents, paints and<br />
other volatile substances.<br />
Electrical <strong>equipment</strong> for use in these areas needs to be designed so<br />
that it cannot ignite an explosive mixture, not only in normal operation<br />
but also in fault conditions. There are a number of methods available to<br />
achieve this but one of the most common is intrinsic safety.<br />
Apollo offer both conventional and intelligent smoke and heat detector<br />
ranges designed to be intrinsically safe, as they meet the requirements<br />
of the ATEX directive.
XP95 Intrinsically Safe (IS) detectors<br />
are a development of the well<br />
established intelligent XP95 range<br />
from Apollo. XP95 IS detectors feature<br />
all the benefits of the standard range,<br />
but are developed specifically for use<br />
in hazardous areas. The addresses of<br />
XP95 IS detectors are set by means of<br />
the patented XPERT card. See page 23<br />
for more details.<br />
Intrinsically Safe 95<br />
XP95 IS<br />
XP95 IS<br />
Intrinsically Safe<br />
Detectors
96<br />
Intrinsically Safe<br />
XP95 IS<br />
XP95 IS Ionisation Smoke Detector<br />
The XP95 IS Ionisation Smoke Detector uses a low<br />
activity radioactive foil to detect fires by irradiating<br />
the air in the smoke chambers and causing a<br />
current flow. If smoke enters the chamber, the<br />
current flow is reduced leading to an alarm.<br />
XP95 IS Ionisation Smoke Detector 55000-540<br />
XP95 IS Optical Smoke Detector<br />
The XP95 IS Optical Smoke Detector works<br />
using the light scatter principle and is ideal for<br />
applications where slow-burning or smouldering<br />
fires are likely.<br />
XP95 IS Optical Smoke Detector 55000-640<br />
XP95 IS Heat Detector<br />
The XP95 IS Heat Detector operates by measuring<br />
heat levels with a single thermistor network which<br />
gives a count output proportional to the external air<br />
temperature.<br />
XP95 IS Heat Detector 55000-440<br />
XP95 IS Mounting Base<br />
The XP95 IS Mounting Base has been designed to<br />
accept only IS products. This ensures that standard<br />
detectors cannot inadvertently be fitted into an<br />
intrinsically safe system. XPERT cards are supplied<br />
with all bases.<br />
XP95 IS Mounting Base 45681-215<br />
XP95 IS Manual Call Point<br />
- Standard Type<br />
The XP95 IS Manual Call Point is based on the<br />
standard waterproof model (58100-950), page<br />
80. It features an “interrupt” facility to provide fast<br />
response to an alarm.<br />
XP95 IS Manual Call Point Standard<br />
Without flap – Red 55100-940<br />
Without flap – Yellow † 55100-942<br />
Without flap Blue/White † 55100-944<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
† Does not have LPCB or CPD approval<br />
• Responds well to fast-burning, flaming fires<br />
• Designed to operate in a variety of<br />
environments<br />
• Minimal effects from temperature, humidity,<br />
atmospheric pressure and wind<br />
• Responds well to slow-burning, smouldering<br />
fires<br />
• Well suited for escape routes<br />
• Unaffected by wind or atmospheric pressure<br />
• Ideal for environments that are dirty or smoky<br />
under normal conditions<br />
• Unaffected by wind or atmospheric pressure<br />
• XPERT addressing<br />
• One way fit<br />
• Only accepts IS detectors<br />
• Reports an alarm in under 0.2 seconds<br />
• Waterproof<br />
• IP67
XP95 IS Manual Call Point<br />
- MEDC Style<br />
The MEDC style Manual Call Point is recommended<br />
for heavy duty applications. This model is made of<br />
glass-reinforced polyester and may be ordered as<br />
break glass or push-button style.<br />
XP95 IS Manual Call Point MEDC Style<br />
Break-glass – Red 55000-960<br />
Break-glass – Yellow 55000-962<br />
Break-glass – Blue 55000-964<br />
Break-glass – Black/Yellow Stripes 55000-966<br />
Break-glass with flap – Red 55000-961<br />
Break-glass with flap – Yellow 55000-963<br />
Break-glass with flap – Blue<br />
Break-glass with flap<br />
55000-965<br />
– Black/Yellow Stripes 55000-967<br />
Push Button – Red 55000-970<br />
Push Button – Yellow 55000-971<br />
Push Button – Blue 55000-972<br />
Push Button – Black/Yellow stripes 55000-973<br />
Protocol Translator and<br />
Galvanic Barrier<br />
The Protocol Translator and Galvanic Barrier are<br />
installed in the safe area ensuring integrity of<br />
communication between control <strong>equipment</strong><br />
and field devices and safety within the limits of<br />
BASEEFA approvals.<br />
XP95 Protocol Translator 55000-855<br />
(single channel)<br />
XP95 Protocol Translator 55000-856<br />
(dual channel)<br />
Galvanic Barrier 29600-098<br />
DIN-Rail Interface Enclosures<br />
DIN-Rail Interface Enclosures are available in two<br />
sizes and can be used for housing intrinsically safe<br />
(IS) barriers or DIN-rail mounted interfaces. A multipurpose<br />
label that features a section for use with<br />
IS systems is supplied. For non-IS systems, the<br />
part referring to IS can simply be removed.<br />
DIN-Rail Interface Enclosure (4 units) 29600-239<br />
DIN-Rail Interface Enclosure (10 units) 29600-240<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
Intrinsically Safe 97<br />
• Reports address in under 0.2 seconds<br />
• Waterproof<br />
• Robust design<br />
XP95 IS<br />
• Loop powered<br />
• Translates voltage levels from a loop driver to<br />
be compatible with IS requirements<br />
• Allows multiple interfaces to be housed<br />
together<br />
• IP67
98<br />
Intrinsically Safe<br />
ORBIS IS<br />
Orbis IS<br />
intrinsically safe<br />
Orbis IS is a range of conventional<br />
detectors which have been developed<br />
from the standard Orbis smoke and<br />
heat detectors. Orbis IS is a range with<br />
modern styling and is electronically<br />
compatible with Apollo Series 60<br />
intrinsically safe conventional detectors.<br />
Orbis IS is a demonstration of Apollo’s<br />
commitment to the market for high<br />
quality conventional detectors for use<br />
in small to medium size installations.<br />
In developing this range, Apollo has<br />
put ease of installation and reliability<br />
in daily operation at the forefront of<br />
considerations.<br />
Features include:<br />
• TimeSaver Base ®<br />
• Patented FasTest ® enabling functional testing in four<br />
seconds<br />
• DirtAlert ® indicates limit of drift compensation<br />
• Tolerates extreme operating conditions: -40°C to +70°C<br />
• False alarm reduction<br />
• Flashing LED option
Orbis IS Optical Smoke Detector<br />
The Orbis IS Optical Smoke Detector works<br />
using the light scatter principle and is ideal for<br />
applications where slow-burning or smouldering<br />
fires are likely.<br />
Orbis IS Optical Smoke ORB-OP-52027-APO<br />
Detector<br />
Orbis IS Optical Smoke ORB-OP-52028-APO<br />
Detector with flashing LED †<br />
Orbis IS Multisensor Smoke Detector<br />
The Orbis IS Multisensor Detector benefits from<br />
the same false alarm technology as the Optical<br />
Detector. It is a thermally enhanced smoke<br />
detector so will not give an alarm from heat alone.<br />
Orbis IS Multisensor ORB-OH-53027-APO<br />
Detector<br />
Orbis IS Multisensor ORB-OH-53028-APO<br />
Detector with flashing LED †<br />
Orbis IS Heat Detector<br />
The Orbis IS Heat Detector monitors temperature<br />
by using a single thermistor network which<br />
provides a voltage output proportional to the<br />
external air temperature. The Orbis IS range<br />
incorporates seven heat detector classes to suit a<br />
wide range of operating conditions.<br />
Orbis IS Heat Detector<br />
Rate of Rise, MAT 50°C<br />
A1R Standard ORB-HT-51145-APO<br />
A1R with Flashing LED †<br />
Static, MAT 50°C<br />
ORB-HT-51146-APO<br />
A1S Standard ORB-HT-51157-APO<br />
A1S with Flashing LED †<br />
Static, MAT 50°C<br />
ORB-HT-51158-APO<br />
A2S Standard ORB-HT-51147-APO<br />
A2S with Flashing LED †<br />
Rate of Rise, MAT 65°C<br />
ORB-HT-51148-APO<br />
BR Standard ORB-HT-51149-APO<br />
BR with Flashing LED †<br />
Static, MAT 65°C<br />
ORB-HT-51150-APO<br />
BS Standard ORB-HT-51151-APO<br />
BS with Flashing LED †<br />
Rate of Rise, MAT 80°C<br />
ORB-HT-51152-APO<br />
CR Standard ORB-HT-51153-APO<br />
CR with Flashing LED †<br />
Static, MAT 80°C<br />
ORB-HT-51154-APO<br />
CS Standard ORB-HT-51155-APO<br />
CS with Flashing LED † ORB-HT-51156-APO<br />
MAT (Maximum Application Temperature)<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
† Does not have VdS approval<br />
Intrinsically Safe 99<br />
ORBIS IS<br />
• Reduces false alarms<br />
• Recommended for early warning of fire in<br />
most areas<br />
• Improved sensitivity to black smoke<br />
• Compensation for slow changes in sensitivity<br />
• Algorithms for reliability of alarm<br />
• Reduces false alarms<br />
• Sensitive to fast burning, flaming fires<br />
• Improved sensitivity to black smoke<br />
• Compensation for slow changes in sensitivity<br />
• Algorithms for reliability of alarm<br />
• Can be used for applications where smoke<br />
detectors are unsuitable<br />
• Ideal for environments that are dirty or smoky<br />
under normal conditions<br />
• Reduced incidences of false alarms<br />
• Increased reliability of <strong>detection</strong>
100<br />
Intrinsically Safe<br />
ORBIS IS<br />
Orbis IS TimeSaver ® Base<br />
The IS TimeSaver ® Base is a completely new<br />
design that provides installers with an open<br />
working area with fixing holes shaped to allow a<br />
simple mounting procedure.<br />
Orbis IS Timesaver ® Base ORB-MB-50018-APO<br />
Orbis IS Adaptor<br />
The Orbis IS Adaptor enables Orbis IS detector<br />
heads to be fitted into existing Series 60 IS<br />
bases in order to upgrade systems with minimal<br />
disruption.<br />
Orbis IS Adaptor ORB-BA-50008-APO<br />
Galvanic Barrier<br />
The Galvanic barrier is installed in the safe area<br />
and ensures system integrity.<br />
Galvanic Barrier 29600-378<br />
DIN-Rail Interface Enclosures<br />
DIN-Rail Interface Enclosures are available in two<br />
sizes and can be used for housing intrinsically safe<br />
(IS) barriers or DIN-rail mounted interfaces. A multipurpose<br />
label that features a section for use with<br />
IS systems is supplied. For non-IS systems, the<br />
part referring to IS can simply be removed.<br />
DIN-Rail Interface Enclosure (4 units) 29600-239<br />
DIN-Rail Interface Enclosure (10 units) 29600-240<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
† Does not have VdS approval<br />
• Grouped terminals to make wiring easy<br />
• Two fixing centres<br />
• LED alignment mark<br />
• Detector locking mechanism<br />
• Allows an existing range to be updated<br />
with ease<br />
• Eliminates the need for re-wiring<br />
• Ideal for conventioanl hazardous areas<br />
• Enables compliance with the ATEX directive<br />
• Allows multiple interfaces to be housed<br />
together<br />
• IP67
Intrinsically Safe 101<br />
ORBIS IS
102<br />
UL<br />
UL<br />
Apollo has developed ranges of detectors for the<br />
American market and those markets which require<br />
UL classification. Apollo has carefully researched<br />
and developed the ranges to ensure that they meet<br />
not only the UL and other standards but also the<br />
demands of today’s high technology environments.
The XP95A range of analog<br />
addressable fire detectors is advanced<br />
in design and performance and offers<br />
unique features that benefit both the<br />
installer and the end user.<br />
The range is based on Apollo’s XP95 range. XP95A has a<br />
‘central intelligence’ system where all the decisions are made<br />
by the control panel. Each detector is addressed using Apollo’s<br />
patented XPERT card, supplied with the mounting bases. The<br />
XP95A range includes an ionization detector, a photo-electric<br />
detector, a heat detector, a multisensor, an isolator and a<br />
series of modules.<br />
Key features of XP95A include:<br />
• XPERT card addressing<br />
• Analog value report<br />
• Address confirmation<br />
• Alarm flag<br />
• Unobtrusive design<br />
• Error check<br />
XP95A UL<br />
UL 103<br />
XP95A
104<br />
UL<br />
XP95A<br />
XP95A Ionization Smoke Detector<br />
The XP95A Ionization Detector uses a low activity<br />
radioactive foil to detect fires by irradiating the<br />
air in the smoke chambers and causing a current<br />
flow. If smoke enters the chamber, the current<br />
flow is reduced leading to an alarm.<br />
XP95A Ionization Smoke Detector † 55000-550<br />
XP95A Ionization Smoke Detector (ULC)* 55000-555<br />
XP95A Photo-Electric Smoke<br />
Detector<br />
The XP95A Photo-Electric Smoke Detector works<br />
on the light-scatter principle and is ideal for<br />
applications where slow-burning or smouldering<br />
fires are likely.<br />
XP95A Photo-Electric Smoke Detector 55000-650<br />
XP95A Heat Detector<br />
The XP95A Heat Detector monitors temperature<br />
by using a single thermistor network which<br />
provides a voltage output proportional to the<br />
external air temperature. It is classified as an<br />
Ordinary detector by UL.<br />
XP95A Heat Detector 55000-450<br />
XP95A Multisensor<br />
The XP95A Multisensor contains a photo-electric<br />
smoke sensor and a thermistor (temperature<br />
sensor) whose outputs are combined to give the<br />
final analog value.<br />
XP95A Multisensor 55000-886<br />
XP95A Loop Powered Beam Detector<br />
The XP95A Beam Detector is made up of three<br />
main parts: the transmitter, which projects a beam<br />
of infra-red light, the receiver, which registers<br />
the light and produces an electric signal, and<br />
the interface, which processes the signal and<br />
generates alarm or fault signals.<br />
XP95A Loop Powered Beam Detector 55000-266<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
† Does not have ULC approval<br />
* Does not have UL approval<br />
• Responds well to fast-burning, flaming fires<br />
• Designed to operate in a variety of<br />
environments<br />
• Minimal effects from temperature, humidity,<br />
atmospheric pressure<br />
• Responds well to slow-burning, smouldering<br />
fires<br />
• Well suited for bedrooms and escape routes<br />
• Unaffected by atmospheric pressure<br />
• Ideal environments that are dirty or smoky<br />
under normal conditions<br />
• Well suited for warehouses, loading bays and<br />
car parks<br />
• Unaffected by wind or atmospheric pressure<br />
• Sensitive to a wide range of fires<br />
• Well suited for environments such as hotel<br />
bedrooms or warehouse loading bays<br />
• Unaffected by wind or atmospheric pressure<br />
• Loop-powered<br />
• Four selectable alarm levels<br />
• Drift Compensation<br />
• Remote interface<br />
• Simple wiring and alignment<br />
• Designed to protect large open spaces such as<br />
museums, churches and warehouses
XP95A Low Power Relay Base<br />
The XP95A Low Power Relay Base incorporates a<br />
low power relay to control field <strong>equipment</strong> such<br />
as automatic door closers.<br />
XP95A Low Power Relay Base 4” 45681-242UL<br />
For information on XPERT cards, please see page 23.<br />
XP95A Mounting Base<br />
All detectors in the XP95A range fit the XP95A<br />
Mounting Base which is a low insertion force<br />
base with stainless steel contacts for the detector<br />
terminals. XPERT cards are supplied with all bases.<br />
XP95A Mounting Base 4” 45681-210USA<br />
XP95A Mounting Base 6” 45681-225USA<br />
E-Z Fit Base<br />
The E-Z fit base is a low profile 6” mounting base<br />
for XP95A detectors.<br />
E-Z Fit Base 45681-250<br />
XP95A Isolating Base<br />
The XP95A Isolating Base senses and detects short<br />
circuit faults on XP95A loops and spurs.<br />
XP95A Isolating Base 45681-321USA<br />
XP95A Isolator<br />
The XP95A Isolator is placed at intervals on the<br />
loop and ensures that, in the case of a short<br />
circuit, only the section between the isolators will<br />
be affected. When the short circuit is removed,<br />
the isolators automatically restore power and data<br />
to the isolated section.<br />
XP95A Isolator 55000-750<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
• XPERT addressing<br />
• One way fit<br />
• Locking feature to prevent unauthorised<br />
removal<br />
• High degree of protection against<br />
unauthorized removal<br />
UL 105<br />
XP95A<br />
• Gives a set of voltage free contacts controlled<br />
by the remote output of a detector<br />
• Draws negligible current<br />
• Up to 20 devices may be installed between<br />
isolating bases<br />
• XPERT addressing<br />
• Detects wiring short-circuits using patented<br />
technology<br />
• Minimises disruption from short-circuits<br />
• Automatic de-isolation on short-circuit removal<br />
• Up to 20 devices may be installed between<br />
isolators
106<br />
UL<br />
XP95A<br />
XP95A Isolator Base<br />
The XP95A Isolator Base is unique and designed to<br />
only accept the XP95A Isolator.<br />
XP95A Isolator Base 45681-211USA<br />
XP95A Mini Priority Switch Monitor Module<br />
The XP95A Mini Priority Switch Monitor is<br />
designed to monitor the state of one or more<br />
single pole, volt free contacts and to report<br />
the status to Apollo compatible analog control<br />
<strong>equipment</strong>. It can also place a signal on the loop<br />
to provide early warning if a device such as a pull<br />
station is operated.<br />
XP95A Mini Priority Switch 55000-830<br />
Monitor Module<br />
XP95A Mini Switch Monitor Module<br />
The XP95A Mini Switch Monitor Module is<br />
designed to monitor the state of one or more<br />
single pole, volt free contacts and to report<br />
the status to Apollo compatible analog control<br />
<strong>equipment</strong>.<br />
XP95A Mini Switch Monitor Module 55000-831<br />
XP95A Switch Monitor Module<br />
The XP95A Switch Monitor Module is designed to<br />
monitor the state of one or more single pole, volt<br />
free contacts connected and to report the status<br />
to Apollo compatible analog control <strong>equipment</strong>.<br />
XP95A Switch Monitor Module 55000-805<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
• Only accepts isolators<br />
• Three input states - ’normal’, ’fault’ and ’alarm’<br />
• Visible LED with remote LED connection option<br />
• Loop powered<br />
• Designed to fit into <strong>equipment</strong> with limited space<br />
• Easy to install<br />
• Monitors <strong>equipment</strong> where a fast response<br />
is required<br />
• Interrupt facility<br />
• Three input states - ’normal’, ’fault’, and ’alarm’<br />
• Visible LED with remote LED connection option<br />
• Loop powered<br />
• Designed to fit into <strong>equipment</strong> with limited space<br />
• Easy to install<br />
• Three input states - ’normal’, ’fault’, and ’alarm’<br />
• Visible LED<br />
• Loop powered
XP95A Priority Switch Monitor<br />
Module<br />
The XP95A Priority Switch Monitor Module is<br />
designed to monitor the state of one or more<br />
single pole, volt free contacts and to report<br />
the status to Apollo compatible analog control<br />
<strong>equipment</strong>. It can also place a signal on the loop<br />
to provide early warning if a device such as a pull<br />
station is operated.<br />
XP95A Priority Switch Monitor 55000-806<br />
Module<br />
XP95A Dual Priority Switch Monitor<br />
Module<br />
The XP95A Dual Priority Switch Monitor Module<br />
contains two priority switch monitor modules<br />
(55000-806) on a single plate.<br />
XP95A Dual Priority Switch Monitor 55000-790<br />
Module<br />
XP95A Switch Monitor Input/Output<br />
Module<br />
The XP95A Switch Monitor Input/Output Module<br />
provides a voltage free, single pole, change-over<br />
relay output, a single, monitored switch input and<br />
unmonitored, non-polarized opto-coupled input.<br />
XP95A Switch Monitor 55000-820<br />
Input/Output Module<br />
XP95A Sounder Control Module<br />
The XP95A Sounder Control Module monitors and<br />
controls the operation of a zone of conventional<br />
sounders and reports their status to the control<br />
panel.<br />
XP95A Sounder Control Module 55000-825<br />
XP95A Relay Output Module<br />
The XP95A Relay Output Module provides a single<br />
2-pole changeover relay.<br />
XP95A Relay Output Module 55000-863<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
• Loop powered<br />
• Fast response time<br />
• Interrupt facility<br />
UL 107<br />
XP95A<br />
• Three input states - ’normal’, ’fault’, and ’alarm’<br />
• Two visible LEDs<br />
• Loop powered<br />
• Fast response time<br />
• Interrupt facility<br />
• It can report fault, switch open and switch<br />
closed levels<br />
• Visible LED<br />
• Loop powered<br />
• Allows sounders to be operated continuously<br />
or be pulsed, 1 second on, 1 second off<br />
• May be synchronized when in pulsed<br />
operation<br />
• Can also be used for public address speakers<br />
• Loop powered<br />
• Can be placed anywhere on loop
108<br />
UL<br />
SERIES 65A<br />
Series 65A<br />
UL<br />
Series 65A is a range of conventional<br />
fire detectors available in three<br />
versions:<br />
• Standard<br />
• Flashing LED<br />
• Flashing LED and magnet operated test switch
Series 65A Ionization Smoke<br />
Detector<br />
The Series 65A Ionization Smoke Detector uses a low<br />
activity radioactive foil to detect fires by irradiating<br />
the air in the smoke chambers and causing a<br />
current flow. If smoke enters the chamber, the<br />
current flow is reduced leading to an alarm.<br />
Series 65A Ionization Smoke Detector<br />
- Standard 55000-227<br />
Series 65A Ionization Smoke Detector 55000-226<br />
with flashing LED<br />
Series 65A Ionization Smoke Detector 55000-225<br />
with flashing LED and magnetic test switch<br />
Series 65A Photo-Electric<br />
Smoke Detector<br />
The Series 65A Photo-Electric Smoke Detector<br />
incorporates a pulsing LED located within the<br />
housing of the detector. The detector housing is<br />
identical to that of the Ionization Detector but has<br />
an indicator LED which is clear in quiescent state<br />
but produces red light in alarm.<br />
Series 65A Photo-Electric Detector<br />
- Standard 55000-327<br />
Series 65A Photo-Electric Detector 55000-326<br />
with flashing LED<br />
Series 65A Photo-Electric Detector 55000-325<br />
with flashing LED and magnetic test switch<br />
S65A Photo-Electric High Sensitivity 55000-328<br />
Series 65A Heat Detector<br />
The Series 65A Heat Detector monitors<br />
temperature by using a dual thermistor network<br />
which provides a voltage output proportional to<br />
the external air temperature.There are nine heat<br />
detectors in the Series 65A range designed to suit<br />
a wide variety of operating conditions.<br />
Series 65A Heat Detector<br />
135°F - Standard 55000-140<br />
135°F - flashing LED 55000-139<br />
135°F - flashing LED and magnetic 55000-138<br />
test switch<br />
170°F - Standard 55000-143<br />
170°F - flashing LED 55000-142<br />
170°F - flashing LED and magnetic 55000-141<br />
test switch<br />
200°F - Standard 55000-146<br />
200°F - flashing LED 55000-145<br />
200°F - flashing LED and magnetic 55000-144<br />
test switch<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
SERIES 65A<br />
• Responds well to fast burning, flaming fires<br />
• Designed to operate in a variety of<br />
environments<br />
• Wide operating voltage<br />
• Flashing LED option<br />
• Flashing LED and magnet operated test switch<br />
option<br />
• Responds well to slow-burning, smouldering<br />
fires<br />
• Well suited for bedrooms and escape routes<br />
• Unaffected by wind or atmospheric pressure<br />
• Wide operating voltage<br />
• Flashing LED option<br />
• Flashing LED and magnet operated test<br />
switch option<br />
• Can be used for applications where smoke<br />
detectors are unsuitable<br />
• Ideal environments that are dirty or smoky<br />
under normal conditions<br />
• Wide operating voltage<br />
• Flashing LED option<br />
• Flashing LED and magnet operated test<br />
switch option<br />
UL 109
110<br />
UL<br />
SERIES 65A<br />
Series 65A Standard Base<br />
The Series 65A Base has been designed to enable<br />
detectors to be fitted without the need of force<br />
– particularly useful when fitting to suspended<br />
ceilings. All Series 65A bases have a ‘one way<br />
only’ fit.<br />
Series 65A Base 4” 45681-200USA<br />
Series 65A Base 6” 48681-220USA<br />
Series 65A Standard Relay Base 4”<br />
The Standard Series 65A Relay Base provides one<br />
set of volt-free, changeover (form C) contacts that<br />
change state when the detector signals an alarm.<br />
Series 65A Standard Relay Base 4” 45681-255<br />
Series 65A Auxiliary Relay Base 4”<br />
The Series 65A Auxiliary Relay Base provides two<br />
sets of volt-free changeover contacts to facilitate<br />
the switching of a remote LED or other auxiliary<br />
device.<br />
Series 65A Auxiliary Relay Base 4” 45681-256<br />
Series 65A End-of-Line Relay Base<br />
The Series 65A End-of-Line (EOL) Relay Base is<br />
intended for use with 4-wire circuits and feature<br />
two sets of changeover contacts and a power<br />
supervision relay.<br />
Series 65A 12V End-of-Line Relay<br />
Base 4” 45681-257<br />
Series 65A 24V End-of-Line Relay<br />
Base 4” 45681-258<br />
Series 65A Low Profile Base 6”<br />
A low profile mounting base for Series 65A<br />
detectors.<br />
Series 65A Low Profile Base 6” 45681-232<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
• Detector locking mechanism<br />
• One way fit<br />
• Easy to wire<br />
• Contains a ground wire terminal<br />
• Contains no electrical parts<br />
• Detector locking mechanism<br />
• One way fit<br />
• Easy to wire<br />
• Contains a ground wire terminal<br />
• Detector locking mechanism<br />
• One way fit<br />
• Easy to wire<br />
• Contains a ground wire terminal<br />
• Detector locking mechanism<br />
• One way fit<br />
• Easy to wire<br />
• Contains a ground wire terminal<br />
• Detector locking mechanism<br />
• One way fit<br />
• Easy to wire<br />
• Contains a ground wire terminal
Series 65A E-Z Fit Base 6”<br />
A low profile mounting base for Series 65A<br />
detectors.<br />
Series 65A E-Z Fit Base 6” 45681-251<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
SERIES 65A<br />
• High degree of protection against unauthorized<br />
removal<br />
UL 111
112<br />
UL<br />
DISCOVERY UL<br />
Discovery<br />
UL<br />
Discovery UL is a range of highspecification,<br />
intelligent fire detectors<br />
developed to meet the requirements of<br />
sophisticated systems while providing<br />
engineers with an additional dimension<br />
in fire protection capability. Discovery<br />
UL has a ‘distributed intelligence<br />
system’ where decisions are made in<br />
the detector head as well as at the<br />
control panel. Drift compensation is<br />
also incorporated into the detector,<br />
allowing it to adapt to dirty or dusty<br />
environments, which reduces false<br />
alarms.<br />
Each detector in the Discovery UL range can operate in<br />
one of five response modes, which can be selected from<br />
the control panel. The response characteristics have<br />
been carefully set so that the detectors comply with the<br />
requirements of the relevant part of UL in all response<br />
modes. Mode One will give a higher sensitivity to fire<br />
than Mode five.<br />
Discovery gives you total reassurance in installations where<br />
adaptability to changing conditions and protection against<br />
unwanted alarms are paramount.<br />
Key features of Discovery UL include:<br />
• Rejection of transient signals<br />
• Flashing LED option<br />
• Five response modes for ease of optimization to<br />
changing environments<br />
• Drift compensation to ensure constant sensitivity<br />
• Four bytes of non-volatile memory for user data<br />
• Alarm flag for fast alarm reporting<br />
• Conventional alarm facility during control panel<br />
processor fault<br />
• 360° visibility in alarm<br />
• Compatible with XP95A systems
Discovery UL Ionization Smoke<br />
Detector<br />
The Ionization detector uses a low activity<br />
radioactive foil to detect fires by irradiating the<br />
air in the smoke chambers and causing a current<br />
flow. If smoke enters the chamber, the current<br />
flow is reduced leading to an alarm.<br />
Discovery UL Ionization Smoke 58000-550<br />
Detector<br />
Discovery UL Photo-Electric Smoke<br />
Detector<br />
The Discovery UL Photo-Electric Smoke Detector<br />
works using the light scatter principle and is<br />
ideal for applications where slow-burning or<br />
smouldering fires are likely.<br />
Discovery UL Photo-Electric 58000-650<br />
Smoke Detector<br />
Discovery UL Heat Detector<br />
The Discovery UL Heat Detector, distinguishable<br />
by the low airflow resistant case, uses a single<br />
thermistor to sense the air temperature around<br />
the detector.<br />
Discovery UL Heat Detector 58000-450<br />
Discovery UL Multisensor Detector<br />
The Discovery UL Multisensor Detector comprises<br />
optical smoke and thermistor temperature sensors<br />
whose outputs are combined to give the final<br />
analog value. As a result, the Multisensor is useful<br />
over a wide range of applications and is highly<br />
immune to false alarms.<br />
Discovery UL Multisensor Detector 58000-750<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
DISCOVERY UL<br />
• Responds well to fast-burning, flaming fires<br />
• Designed to operate in a variety of<br />
environments<br />
• Remote test feature<br />
• Responds well to slow-burning, smouldering<br />
fires<br />
• Well suited for bedrooms and escape routes<br />
• Unaffected by wind or atmospheric pressure<br />
• Remote test feature<br />
• Ideal environments that are dirty or smoky<br />
under normal conditions<br />
• Well suited for warehouses, loading bays and<br />
car parks<br />
• Unaffected by wind or atmospheric pressure<br />
• Remote test feature<br />
• Ideal for wide range of applications<br />
• Highly immune to false alarms<br />
• Well suited for sensitive environments<br />
• Unaffected by wind or atmospheric pressure<br />
• Remote test feature<br />
UL 113
114<br />
UL<br />
DISCOVERY UL<br />
XP95A Mounting Base<br />
All detectors in the Discovery UL range fit the<br />
XP95A Mounting Base. The Mounting Base is<br />
a low insertion force base with stainless steel<br />
contacts for the detector terminals. XPERT cards<br />
are supplied with all bases.<br />
XP95A Mounting Base 4” 45681-210USA<br />
XP95A Mounting Base 6” 45681-225USA<br />
E-Z Fit Base<br />
The E-Z Fit Base is a low profile 6” mounting base<br />
for Discovery UL detectors.<br />
E-Z Fit Base 45681-250<br />
XP95A Isolating Base<br />
The XP95A Isolating Base senses and detects short<br />
circuit faults on Discovery UL loops and spurs.<br />
XP95A Isolating Base 45681-321USA<br />
XP95A Isolator<br />
The XP95A Isolator can be used on a Discovery<br />
UL loop and is placed at intervals on the loop and<br />
ensures that, in the case of a short circuit, only<br />
the section between the isolators will be affected.<br />
When the short circuit is removed, the isolators<br />
automatically restore power and data to the<br />
isolated section.<br />
XP95A Isolator 55000-750<br />
XP95A Isolator Base<br />
The XP95A Isolator Base is unique and designed to<br />
only accept the XP95A isolator. However, both can<br />
be used with a Discovery UL system.<br />
XP95A Isolator Base 45681-211USA<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
• XPERT addressing<br />
• One way fit<br />
• Locking feature to prevent unauthorised<br />
removal<br />
• High degree of protection against unauthorised<br />
removal<br />
• Up to 20 devices may be installed between<br />
isolating bases<br />
• Detects wiring short circuits using patented<br />
technology<br />
• Minimises disruption from short-circuits<br />
• Automatic de-isolation on short-circuit removal<br />
• Up to 20 devices may be installed between<br />
isolators<br />
• Only accepts the XP95A Isolator
DISCOVERY UL<br />
UL 115
116<br />
Test Equipment and Maintenance<br />
Test<br />
Equipment &<br />
Maintenance<br />
To keep a fire <strong>detection</strong> system in good working<br />
order, it should be subject to a routine maintenance<br />
programme in accordance with locally applicable<br />
regulations. Over the course of a year, every<br />
detector in the system should be functionally tested<br />
at least once, using recommended <strong>equipment</strong>.<br />
Apollo offer a range of test <strong>equipment</strong>, for both<br />
conventional and intelligent systems to enable you<br />
to do this.
XP95 Test Set<br />
The XP95 Test Set is a self-contained, portable<br />
test unit capable of providing a number of useful<br />
functions in relation to individual detectors,<br />
ancillary devices or complete circuits of analogue<br />
addressable devices in the Apollo intelligent<br />
ranges. The main function of the test set is to help<br />
the engineer guarantee correct loop configuration<br />
before an active control panel is installed.<br />
XP95 Test Set 55000-870EUR<br />
Discovery Programmer<br />
The Discovery Programmer is a portable test and<br />
configuration tool for Discovery smoke and heat<br />
detectors.<br />
Discovery Programmer 53832-030<br />
Accessories:<br />
Conventional Test Set<br />
The Conventional Test Set is an invaluable tool<br />
designed to give a thorough on-site check of<br />
conventional fire detectors within the Apollo<br />
Series 65 and AlarmSense range. Each Test Set<br />
is supplied with a link head, mains adaptor and<br />
carrying case with shoulder strap.<br />
Conventional Test Set 53832-020<br />
Flame Sensor Test Unit and Case<br />
The Flame Sensor Test Kit is a tool which is<br />
designed to test flame detectors without the<br />
need of real flames.<br />
Test Equipment and Maintenance 117<br />
TEST EQUIPMENT AND MAINTENANCE<br />
• User friendly LCD information display<br />
• Speedy commissioning<br />
• Option for hard copy of results<br />
• No unnecessary site visits<br />
• Significant cost reductions<br />
• Look up the date of manufacture<br />
• Check the drift compensation value<br />
• Display and change the operating mode<br />
• Select/de-select LED flash mode<br />
• Tests detectors<br />
• Reads approval codes<br />
Product Name Part Number<br />
Printer for XP95 Test Set 55000-872<br />
Flame Sensor Test Unit and Case 29600-226<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
• Easy to use<br />
• 2 button select/accept options<br />
• LCD for clear display<br />
• Mimics the characteristics of real flames
118<br />
Test Equipment and Maintenance<br />
TEST EQUIPMENT AND MAINTENANCE<br />
In addition to the main test kits, Apollo provide a range of <strong>equipment</strong><br />
to enable you to keep your system in good working order.<br />
Product Name<br />
FOR INSTALLATION AND REMOVAL OF DETECTORS:<br />
Part Number<br />
Detector Extract Tool 29600-102<br />
Extension Pole, 1.13m 29600-103<br />
Telescopic Pole, 1.26m to 4.5m 29600-104<br />
1.5mm Hexagonal Driver (locks detectors to bases) 29600-095<br />
XPERT Card Insertion Tool<br />
FOR IN SITU FUNCTIONAL TESTING OF INDIVIDUAL DETECTORS:<br />
Solo<br />
45681-235<br />
Smoke Dispenser Head 29600-100<br />
Aerosol Test Gas 29600-225<br />
Heat Detector Test Pole (240V) 29600-229<br />
Heat Detector Test Pole (110V) 29600-231<br />
Cordless Heat Tester Kit 29600-212<br />
Cordless Heat Detector Tester 29600-213<br />
CO Test Gas 29600-235<br />
Detector Duster 29600-449<br />
Battery Batons 29600-183<br />
Battery Charger*<br />
Testifire<br />
29600-214<br />
Smoke/Heat Unit 29600-459<br />
Smoke/Heat Kit 29600-460<br />
Smoke/Heat/CO Unit 29600-461<br />
Smoke/Heat/CO Kit 29600-462<br />
6-Pack Replacement Smoke Capsule 29600-463<br />
3-Pack Replacement Smoke Capsule 29600-464<br />
6-Pack Replacement CO Capsule 29600-465<br />
3-Pack Replacement CO Capsule 29600-466<br />
Battery Batons 29600-183<br />
Battery Charger* 29600-214<br />
Aerosol Test Gas<br />
29600-225<br />
CO Test Gas<br />
29600-235<br />
Telescopic Pole,<br />
1.26m to 4.5m<br />
29600-104<br />
Please check the Apollo website on a regular basis for up-to-date approvals information.<br />
*When ordering please state if you require an EU lead or UK lead.<br />
Extension Pole,1.13m<br />
29600-103
Test Equipment and Maintenance 119<br />
TEST EQUIPMENT AND MAINTENANCE
120<br />
Additional Services<br />
Additional<br />
Services
Loop Calculator<br />
The Apollo Loop Calculator is a free computer programme used<br />
to establish the viability of a design. It enables engineers to<br />
calculate the total loop loading in a proposed Discovery or XP95<br />
fire <strong>detection</strong> system by inputting relevant variables, for example<br />
control <strong>equipment</strong>, loop devices and cable length and type.<br />
Parameters are included for Apollo protocol compatible panels.<br />
Please see the Apollo website for more details<br />
www.apollo-fire.co.uk/loop-calc<br />
SimSystem<br />
SimSystem is a tool for simulating loops of detectors and<br />
interfaces in order to demonstrate a system and prove the<br />
design without having to connect actual products to a control<br />
panel. SimSystem consists of a software programme which<br />
features an intuitive graphical display and an interface which<br />
runs up to four loops. A maximum of two interfaces can be<br />
connected, thus allowing a system of up to eight loops to be<br />
simulated.<br />
Training<br />
Apollo offers a series of free one-day training courses for its<br />
customers. The courses cover the following modules:<br />
Module 1: Detection Principles & Device Selection<br />
Module 1.1: Carbon Monoxide <strong>Fire</strong> Detection (Coming soon)<br />
Module 2: Conventional Detector Operation<br />
Module 2.1: AlarmSense<br />
Module 2.2: Orbis (Coming soon)<br />
Module 3: Analogue Addressable Principles<br />
Module 3.1: XP95<br />
Module 3.2: Discovery<br />
Module 3.3: XPlorer<br />
Module 3.4: AV Alarm Devices (Coming soon)<br />
Module 3.5: XPander<br />
Module 4: Intrinsically Safe Equipment (Coming soon)<br />
Module 5: Service, Test & Maintenance<br />
In addition to the standard training courses, Apollo can offer<br />
tailor-made courses if required. The majority of courses are held<br />
at Apollo’s head office, but on-site training is also available.<br />
You can find out more about Apollo’s training days and book your<br />
place by visiting www.apollo-fire.co.uk/training<br />
Additional Services 121
122<br />
Approvals<br />
Approvals<br />
Apollo <strong>Fire</strong> Detectors has a library that contains<br />
hundreds of different types of product certificate<br />
that have been obtained from many different<br />
national and international bodies. Listed below is<br />
a small selection. Please see our website for more<br />
details and up-to-date approvals information.<br />
Loss Prevention Certification Board (LPCB)<br />
The LPCB is an international certification body who<br />
specialises in the fields of security and fire protection. LPCB<br />
approval is recognised by governments and regulatory<br />
authorities worldwide, particularly in Europe, the Asia-Pacific<br />
and the Middle East. The LPCB approval process involves<br />
the assessment and testing of products to ensure that they<br />
meet quality standards set by a team of industry experts.<br />
Testing is carried out in-house by LPCB and the approval<br />
is maintained by regular audits to ensure that the product<br />
continues to meet the approval criteria.<br />
Apollo products with LPCB approval:<br />
Orbis<br />
Class A1R Heat Detector ORB-HT-11001-APO<br />
Class A1R Heat Detector with flashing LED ORB-HT 11013-APO<br />
Class A1S Heat Detector ORB-HT-11166-APO<br />
Class A1S Heat Detector with flashing LED ORB-HT-11167-APO<br />
Class A2S Heat Detector ORB-HT-11002-APO<br />
Class A2S Heat Detector with flashing LED ORB-HT-11014-APO<br />
Class BR Heat Detector ORB-HT-11003-APO<br />
Class BR Heat Detector with flashing LED ORB-HT-11015-APO<br />
Class BS Heat Detector ORB-HT-11004-APO<br />
Class BS Heat Detector with flashing LED ORB-HT-11016-APO<br />
Class CR Heat Detector ORB-HT-11005-APO<br />
Class CR Heat Detector with flashing LED ORB-HT-11017-APO<br />
Class CS Heat Detector ORB-HT-11006-APO<br />
Class CS Heat Detector with flashing LED ORB-HT-11018-APO<br />
Optical Smoke Detector ORB-OP-12001-APO<br />
Optical Smoke Detector with flashing LED ORB-OP-12003-APO<br />
Multisensor Smoke Detector ORB-OH-13001-APO<br />
Multisensor Smoke Detector ORB-OH-13003-APO<br />
with flashing LED<br />
TimeSaver Base ORB-MB-00001-APO<br />
TimeSaver Base LX ORB-MB-00002-APO<br />
TimeSaver Relay Base ORB-RB-10004-APO<br />
TimeSaver Deep Base ORB-MB-00019-APO<br />
Orbis IS<br />
Class A1R Heat Detector ORB-HT-51145-APO<br />
Class A1R Heat Detector with flashing LED ORB-HT-51146-APO<br />
Class A1S Heat Detector ORB-HT-51147-APO<br />
Class A1S Heat Detector with flashing LED ORB-HT-51158-APO<br />
Class A2S Heat Detector ORB-HT-51157-APO<br />
Class A2S Heat Detector with flashing LED ORB-HT-51148-APO<br />
Class BR Heat Detector ORB-HT-51149-APO<br />
Class BR Heat Detector with flashing LED ORB-HT-51150-APO<br />
Class BS Heat Detector ORB-HT-51151-APO<br />
Class BS Heat Detector with flashing LED ORB-HT-51152-APO<br />
Class CR Heat Detector ORB-HT-51153-APO<br />
Class CR Heat Detector with flashing LED ORB-HT-51154-APO<br />
Class CS Heat Detector ORB-HT-51155-APO<br />
Class CS Heat Detector with flashing LED ORB-HT-51156-APO<br />
Multisensor Detector ORB-OH-53027-APO<br />
Multisensor Detector with flashing LED ORB-OH-53028-APO<br />
Optical Smoke Detector ORB-OP-52027-APO<br />
Optical Smoke Detector with flashing LED ORB-OP-52028-APO<br />
Adaptor ORB-BA-10008-APO<br />
TimeSaver Base ORB-MB-50018-APO<br />
Series 65<br />
Class A1R Heat Detector with<br />
flashing LED and magnetic test switch<br />
55000-120<br />
Class A1R Heat Detector with flashing LED 55000-121<br />
Class A1R Heat Detector 55000-122<br />
Class BR Heat Detector with<br />
flashing LED and magnetic test switch<br />
55000-125<br />
Class BR Heat Detector with flashing LED 55000-126<br />
Class BR Heat Detector 55000-127<br />
Class CR Heat Detector with<br />
flashing LED and magnetic test switch<br />
55000-130<br />
Class CR Heat Detector with flashing LED 55000-131<br />
Class CR Heat Detector 55000-132<br />
Class CS Heat Detector with<br />
flashing LED and magnetic test switch<br />
55000-135<br />
Class CS Heat Detector with flashing LED 55000-136<br />
Class CS Heat Detector 55000-137<br />
Integrating Ionisation Smoke Detector<br />
with flashing LED and magnetic test switch<br />
55000-218
Integrating Ionisation Smoke Detector 55000-219<br />
with flashing LED<br />
Integrating Ionisation Smoke Detector 55000-220<br />
Ionisation Smoke Detector with 55000-215<br />
flashing LED and magnetic test switch<br />
Ionisation Smoke Detector with flashing LED 55000-216<br />
Ionisation Smoke Detector 55000-217<br />
Optical Smoke Detector with 55000-315<br />
flashing LED and magnetic test switch<br />
Optical Smoke Detector with flashing LED 55000-316<br />
Optical Smoke Detector 55000-317<br />
Standard Base 45681-200<br />
Diode Base 45681-201<br />
Standard Relay Base 45681-245<br />
Auxiliary Contacts Base 45681-246<br />
Relay 12V EOL Base 45681-247<br />
Relay 24V EOL Base 45681-248<br />
XP95<br />
Class CS Heat Detector 55000-401<br />
Class A2S Heat Detector 55000-400<br />
Ionisation Smoke Detector 55000-500<br />
Optical Smoke Detector 55000-600<br />
Multisensor Detector 55000-885<br />
Mounting Base 45681-210<br />
20D Isolating Base 45681-284<br />
Low Power Relay Base 45681-242<br />
Manual Call Point (Surface) 55100-905<br />
Manual Call Point with Isolator (Surface) 55100-908<br />
Isolator Base 45681-211<br />
XP95 Interfaces<br />
Three Channel Input/Output Unit 55000-588<br />
Switch Monitor Plus 55000-841<br />
Switch Monitor 55000-843<br />
Zone Monitor 55000-845<br />
Input/Output Unit 55000-847<br />
Output Unit 55000-849<br />
Sounder Control Unit 55000-852<br />
XP95 IS<br />
Class A2S Heat Detector 55000-440<br />
Ionisation Smoke Detector 55000-540<br />
Optical Smoke Detector 55000-640<br />
Standard Manual Call Point 55100-940<br />
Standard Base 45681-215<br />
Discovery<br />
Heat Detector - Variable Temperature 58000-400<br />
Ionisation Smoke Detector 58000-500<br />
Optical Smoke Detector 58000-600<br />
Multisensor Detector 58000-700<br />
Mounting Base 45681-210<br />
20D Isolating Base 45681-284<br />
Manual Call Point (Surface) 58100-908<br />
Manual Call Point (Surface) 58100-910<br />
Approvals 123<br />
VdS<br />
VdS is an international and independent testing and<br />
certification body based in Germany who specialises in the<br />
fields of fire prevention and security. With over 100 years<br />
experience, VdS inspects and certifies products to ensure<br />
they meet standards jointly established by VdS and industry<br />
experts.<br />
Apollo products with VdS approval:<br />
Orbis<br />
Class A1R Heat Detector ORB-HT-11001-APO<br />
Class A1S Heat Detector ORB-HT-11166-APO<br />
Class A2S Heat Detector ORB-HT-11002-APO<br />
Class BR Heat Detector ORB-HT-11003-APO<br />
Class BS Heat Detector ORB-HT-11004-APO<br />
Class CR Heat Detector ORB-HT-11005-APO<br />
Class CS Heat Detector ORB-HT-11006-APO<br />
Optical Smoke Detector ORB-OP-12001-APO<br />
Multisensor Smoke Detector ORB-OH-13001-APO<br />
TimeSaver Base ORB-MB-00001-APO<br />
TimeSaver LX Base ORB-MB-00002-APO<br />
TimeSaver Diode Base ORB-DB-00003-APO<br />
TimeSaver Relay Base ORB-RB-10004-APO<br />
Orbis IS<br />
Class A1R Heat Detector ORB-HT-51145-APO<br />
Class A1S Heat Detector ORB-HT-51147-APO<br />
Class A2S Heat Detector ORB-HT-51157-APO<br />
Class BR Heat Detector ORB-HT-51149-APO<br />
Class BS Heat Detector ORB-HT-51151-APO<br />
Class CR Heat Detector ORB-HT-51153-APO<br />
Class CS Heat Detector ORB-HT-51155-APO<br />
Multisensor Detector ORB-OH-53027-APO<br />
Optical Smoke Detector ORB-OP-52027-APO<br />
Adaptor ORB-BA-10008-APO<br />
TimeSaver Base ORB-MB-50018-APO<br />
Series 65<br />
Class A1R Heat Detector 55000-122<br />
Class BR Heat Detector 55000-127<br />
Class CR Heat Detector 55000-132<br />
Class CS Heat Detector 55000-137<br />
Ionisation Smoke Detector 55000-217<br />
Integrating Ionisation Smoke Detector 55000-220<br />
Optical Smoke Detector 55000-317<br />
Standard Base 45681-200<br />
Standard Relay Base 45681-245<br />
Auxiliary Contacts Base 45681-246<br />
Relay Base - 12V EOL 45681-247<br />
Relay Base - 24V EOL 45681-248<br />
XP95<br />
XP95 Heat Detector 55000-420<br />
Ionisation Smoke Detector 55000-520<br />
Optical Smoke Detector 55000-620
124<br />
Approvals<br />
Multisensor Detector 55000-885<br />
20D Positive Short Circuit Isolator 55000-710<br />
20D Negative Short Circuit Isolator 55000-720<br />
Isolator Base 45681-211<br />
Interfaces<br />
Three Channel Input/Output Unit 55000-588<br />
Switch Monitor Plus 55000-841<br />
Switch Monitor 55000-843<br />
Zone Monitor 55000-845<br />
Input/Output Unit 55000-847<br />
Output Unit 55000-849<br />
Sounder Control Unit 55000-852<br />
Sounders<br />
Integrated Base Sounder DIN tone 45681-300<br />
Sounder Beacon Base 45681-334<br />
Discovery<br />
Variable Temperature Heat Detector 58000-400<br />
Ionisation Smoke Detector 58000-500<br />
Optical Smoke Detector 58000-600<br />
Multisensor Detector 58000-700<br />
Mounting Base 45681-210<br />
UL<br />
Underwriters Laboratories (UL) is an independent<br />
product certification body based in the United States.<br />
UL test products against standards set by a team of industry<br />
experts and potential customers. There are no laws which<br />
specify that a UL mark must be used on a product, however,<br />
in the US there are many municipalities that have laws,<br />
codes or regulations which require a product to be tested by<br />
a recognised testing laboratory such as UL before it can be<br />
sold in their area.<br />
Apollo products with UL approval:<br />
Series 65A<br />
Heat Detector 135°F - flashing LED 55000-138<br />
and magnetic test switch<br />
Heat Detector 135°F - flashing LED 55000-139<br />
Heat Detector 135°F - Standard 55000-140<br />
Heat Detector 170°F - flashing LED 55000-141<br />
and magnetic test switch<br />
Heat Detector 170°F - flashing LED/ 55000-142<br />
Heat Detector 170°F - Standard 55000-143<br />
Heat Detector 200°F - flashing LED 55000-144<br />
and magnetic test switch<br />
Heat Detector 200°F - flashing LED 55000-145<br />
Heat Detector 200°F - Standard 55000-146<br />
Ionization Smoke Detector - flashing LED 55000-225<br />
and magnetic test switch<br />
Ionization Smoke Detector with flashing LED 55000-226<br />
Ionization Smoke Detector - Standard 55000-227<br />
Photo-Electric Smoke Detector flashing LED 55000-325<br />
and magnetic test switch<br />
Photo-Electric Smoke Detector 55000-326<br />
with flashing LED<br />
Photo-Electric Smoke Detector - Standard 55000-327<br />
Standard Base 4” 45681-200<br />
Standard Base 6” 45681-220<br />
Low Profile Base 6” 45681-232<br />
E-Z Fit Base 45681-251<br />
4” Conventional Standard Relay Base 45681-255<br />
4” Conventional Auxiliary Contact Base 45681-256<br />
4” Conventional Relay 12V EOL Base 45681-257<br />
4” Conventional Relay 24V EOL Base 45681-258<br />
XP95A<br />
Beam Detector 55000-266<br />
High Temperature Heat Detector 55000-450<br />
Ionization Smoke Detector 55000-550<br />
Photo-Electric Smoke Detector 55000-650<br />
Multisensor Detector 55000-886<br />
Negative Isolator 55000-750<br />
4” Addressable Base 45681-210<br />
Isolator Base 45681-211<br />
6” Addressable Base 45681-225<br />
6” Addressable Low Profile Relay Base 45681-242<br />
6” Addressable E-Z Fit Base 45681-250<br />
20D Negative Isolating Base 45681-321<br />
XP95A Interfaces<br />
Dual Switch Monitor 55000-790<br />
Switch Monitor 55000-805<br />
Priority Switch Monitor 55000-806<br />
Switch Monitor Input/Output Unit 55000-820<br />
Sounder Control Unit 55000-825<br />
Mini Priority Switch Monitor 55000-830<br />
Mini Switch Monitor 55000-831<br />
Relay Output Module 55000-863<br />
Discovery<br />
Variable Temperature Heat Detector 58000-450<br />
Ionization Smoke Detector 58000-550<br />
Photo-Electric Smoke Detector 58000-650<br />
Multisensor Detector 58000-750<br />
ULC (Underwriters Laboratory of Canada)<br />
ULC is an independent product certification body that<br />
undertakes the quarterly inspection of manufacturers to<br />
ensure continued compliance of UL Listed/Recognised<br />
products to Agency reports and safety standards. This<br />
work is done under contract to UL Inc (Follow-up Services<br />
Division). They are not a branch or subsidiary of UL.<br />
Apollo products with ULC approval:<br />
XP95A<br />
Ionization Smoke Detector 55000-555<br />
Photo-Electric Smoke Detector 55000-650<br />
Heat Detector 55000-450
Isolator 55000-750<br />
Multisensor Detector 55000-886<br />
Mounting Base 4” 45681-210USA<br />
Isolator Base 45681-211<br />
Mounting Base 6” 45681-225USA<br />
Low Power Relay Base 4” 45681-242<br />
E-Z Fit Base 45681-250<br />
Isolating Base 45681-321<br />
XP95A Interfaces<br />
Mini Priority Switch Monitor Module 55000-830<br />
Mini Switch Monitor Module 55000-831<br />
Switch Monitor Module 55000-805<br />
Priority Switch Monitor Module 55000-806<br />
Switch Monitor Input/Output Module 55000-820<br />
Sounder Control Module 55000-825<br />
Relay Output Module 55000-863<br />
Series 65A<br />
Photo-Electric Smoke Detector Standard 55000-327<br />
Photo-Electric Smoke Detector with 55000-326<br />
flashing LED<br />
Photo-Electric Smoke Detector with 55000-325<br />
flashing LED and magnetic test switch<br />
135°F Heat Detector Standard 55000-140<br />
135°F Heat Detector with flashing LED 55000-139<br />
135°F Heat Detector with flashing LED 55000-138<br />
and magnetic test switch<br />
170°F Heat Detector Standard 55000-143<br />
170°F Heat Detector with flashing LED 55000-142<br />
170°F Heat Detector with flashing LED 55000-141<br />
and magnetic test switch<br />
200°F Heat Detector Standard 55000-146<br />
200°F Heat Detector with flashing LED 55000-145<br />
200°F Heat Detector with flashing LED 55000-144<br />
and magnetic test switch<br />
Standard Relay Base 4” 45681-255<br />
Auxiliary Relay Base 4” 45681-256<br />
12V End-of-Line Relay Base 4” 45681-257<br />
24V End-of-Line Relay Base 4” 45681-258<br />
E-Z Fit Base 6” 45681-251<br />
Discovery UL<br />
Photo-Electric Smoke Detector 58000-650<br />
Heat Detector 58000-450<br />
Multisensor Detector 58000-750<br />
Mounting Base 4” 45681-210USA<br />
Mounting Base 6” 45681-225USA<br />
E-Z Fit Base 45681-250<br />
FM<br />
FM Approvals certifies products and services with a<br />
unique focus on objectively testing property loss prevention<br />
products and services and certifying those that meet<br />
rigorous loss prevention standards.<br />
Apollo products with FM approval:<br />
XP95A<br />
Ionization Smoke Detector 55000-550<br />
Photo-Electric Smoke Detector 55000-650<br />
Heat Detector 55000-450<br />
Mounting Base 4” 45681-210USA<br />
Mounting Base 6” 45681-225USA<br />
Isolator 55000-750<br />
Discovery UL<br />
Mounting Base 4” 45681-210USA<br />
Mounting Base 6” 45681-225USA<br />
Isolator 55000-750<br />
CCCF<br />
<strong>Fire</strong> Product Type Approval or CCCF Approval is a<br />
compulsory certification for fire products entering the<br />
China market.<br />
Apollo products with CCCF approval:<br />
XP95<br />
Grade 2 Heat Detector 55000-420<br />
Ionisation Smoke Detector 55000-520<br />
Optical Smoke Detector 55000-620<br />
Surface Mount Manual Call Point 55000-905<br />
Flush Mount Manual Call Point 55000-906<br />
Discovery<br />
Discovery Heat Detector 58000-400MAC<br />
Discovery Ionisation Smoke Detector 58000-500MAC<br />
Discovery Optical Smoke Detector 58000-600MAC<br />
Discovery Multisensor Detector 58000-700MAC<br />
Discovery UL Heat Detector 58000-450<br />
Discovery UL Ionization Smoke Detector 58000-550<br />
Discovery UL Photo-Electric Smoke Detector 58000-650<br />
Discovery UL Multisensor Detector 58000-750<br />
Discovery Manual call Point with Isolator 58100-908<br />
Red (Surface)<br />
Discovery Manual Call Point - Red (Surface) 58100-910<br />
Approvals 125<br />
Orbis<br />
Orbis Optical Smoke Detector with ORB-OP-12003-PRC<br />
flashing LED<br />
Orbis Multisensor with flashing LED ORB-OH-13003-PRC<br />
Orbis A1R Heat Detector with flashing LED ORB-HT-11013-PRC<br />
Orbis A2S Heat Detector with flashing LED ORB-HT-11014-PRC<br />
Orbis BR Heat Detector with flashing LED ORB-HT-11015-PRC<br />
Orbis BS Heat Detector with flashing LED ORB-HT-11016-PRC<br />
Orbis CR Heat Detector with flashing LED ORB-HT-11017-PRC<br />
Orbis CS Heat Detector with flashing LED ORB-HT-11018-PRC<br />
Orbis Marine Optical Smoke Detector ORB-OP-42003-MAC<br />
with flashing LED<br />
Orbis Marine Multisensor Detector ORB-OH-43003-MAC<br />
with flashing LED<br />
Orbis Marine A1R Heat Detector with flashing LED ORB-HT-41013-MAC
126<br />
Approvals<br />
Orbis Marine A2S Heat Detector with flashing LED ORB-HT-41014-MAC<br />
Orbis Marine BR Heat Detector with flashing LED ORB-HT-41015-MAC<br />
Orbis Marine BS Heat Detector with flashing LED ORB-HT-41016-MAC<br />
Orbis Marine CR Heat Detector with flashing LED ORB-HT-41017-MAC<br />
Orbis Marine CS Heat Detector with flashing LED ORB-HT-41018-MAC<br />
XP95<br />
XP95 Waterproof Manual Call Point 55000-950<br />
Orbis IS Detectors<br />
Orbis IS A1R Heat Detector with flashing LED ORB-HT-51146-PRC<br />
Orbis IS A2S Heat Detector with flashing LED ORB-HT-51148-PRC<br />
Orbis IS BR Heat Detector with flashing LED ORB-HT-51150-PRC<br />
Orbis IS BS Heat Detector with flashing LED ORB-HT-51152-PRC<br />
Orbis IS CR Heat Detector with flashing LED ORB-HT-51154-PRC<br />
Orbis IS CS Heat Detector with flashing LED ORB-HT-51156-PRC<br />
Orbis IS Optical Smoke Detector with flashing LED ORB-OP-52028-PRC<br />
Orbis IS Multisensor with flashing LED ORB-OH-53028-PRC<br />
XP95 IS<br />
XP95 IS Heat Detector 55000-440<br />
XP95 IS Ionisation Smoke Ddetector 55000-540<br />
XP95 IS Optical Smoke Detector 55000-640<br />
XP95 IS Manual Call Point without flap - red 55000-940<br />
XP95 IS Manual Call Point MEDC 58100-970<br />
Push Button -red<br />
XP95 IS Manual Call Point MEDC 58100-971<br />
Push Button - yellow<br />
Construction Products Directive (CPD)<br />
The CPD is one of the ‘New Approach’ Directives to<br />
create a single European market by removing technical<br />
barriers to trade between Member States. Products which<br />
meet the essential requirements of the relevant directives<br />
will be eligible for CE marking and may be placed on the<br />
market anywhere within the EEA.<br />
Apollo products with CPD approval:<br />
AlarmSense<br />
Integrating Optical Detector 55000-391<br />
Heat Detector A1R 55000-190<br />
Heat Detector CS 55000-193<br />
Base 45681-244<br />
Sounder Base LR 45681-341<br />
Sounder Base 45681-510<br />
Sounder Beacon Base LR 45681-509<br />
Sounder Beacon Base 45681-509<br />
Manual Call Point (Surface) 55000-894<br />
Series 65<br />
Class A1R Heat Detector with 55000-120<br />
flashing LED and magnetic test switch<br />
Class A1R Heat Detector with flashing LED 55000-121<br />
Class A1R Heat Detector 55000-122<br />
Class BR Heat Detector with 55000-125<br />
flashing LED and magnetic test switch<br />
Class BR Heat Detector with flashing LED 55000-126<br />
Class BR Heat Detector 55000-127<br />
Class CR Heat Detector with 55000-130<br />
flashing LED and magnetic test switch<br />
Class CR Heat Detector with flashing LED 55000-131<br />
Class CR Heat Detector 55000-132<br />
Class CS Heat Detector with 55000-135<br />
flashing LED and magnetic test switch<br />
Class CS Heat Detector with flashing LED 55000-136<br />
Class CS Heat Detector 55000-137<br />
French Ionisation Smoke Detector 55000-208<br />
French Optical Smoke Detector 55000-308<br />
Ionisation Smoke Detector with 55000-215<br />
flashing LED and magnetic test switch<br />
Ionisation Smoke Detector with flashing LED 55000-216<br />
Ionisation Smoke Detector 55000-217<br />
Integrating Ionisation Smoke Detector 55000-218<br />
with flashing LED and magnetic test switch<br />
Integrating Ionisation Smoke Detector 55000-219<br />
with flashing LED<br />
Integrating Ionisation Smoke Detector 55000-220<br />
Optical Smoke Detector with 55000-315<br />
flashing LED and magnetic test switch<br />
Optical Smoke Detector with flashing LED 55000-316<br />
Optical Smoke Detector 55000-317<br />
Standard Base 45681-200<br />
Standard Relay Base 45681-245<br />
Auxiliary Relay Base 45681-246<br />
Relay 12V EOL Base 45681-247<br />
Relay 24V EOL Base 45681-248<br />
Orbis<br />
Class A1R Heat Detector ORB-HT-11001-APO<br />
Class A1R Heat Detector with flashing LED ORB-HT 11013-APO<br />
Class A1S Heat Detector ORB-HT-11166-APO<br />
Class A1S Heat Detector with flashing LED ORB-HT-11167-APO<br />
Class A2S Heat Detector ORB-HT-11002-APO<br />
Class A2S Heat Detector with flashing LED ORB-HT-11014-APO<br />
Class BR Heat Detector ORB-HT-11003-APO<br />
Class BR Heat Detector with flashing LED ORB-HT-11015-APO<br />
Class BS Heat Detector ORB-HT-11004-APO<br />
Class BS Heat Detector with flashing LED ORB-HT-11016-APO<br />
Class CR Heat Detector ORB-HT-11005-APO<br />
Class CR Heat Detector with flashing LED ORB-HT-11017-APO<br />
Class CS Heat Detector ORB-HT-11006-APO<br />
Class CS Heat Detector with flashing LED ORB-HT-11018-APO<br />
Optical Smoke Detector ORB-OP-12001-APO<br />
Optical Smoke Detector with flashing LED ORB-OP-12003-APO<br />
Multisensor Smoke Detector ORB-OH-13001-APO<br />
Multisensor Smoke Detector ORB-OH-13003-APO<br />
with flashing LED<br />
TimeSaver Base ORB-MB-00001-APO<br />
TimeSaver Base LX ORB-MB-00002-APO<br />
TimeSaver Deep Base ORB-MB-00019-APO
Orbis IS<br />
Class A1R Heat Detector ORB-HT-51145-APO<br />
Class A1R Heat Detector with flashing LED ORB-HT-51146-APO<br />
Class A1S Heat Detector ORB-HT-51157-APO<br />
Class A1S Heat Detector with flashing LED ORB-HT-51158-APO<br />
Class A2S Heat Detector ORB-HT-51147-APO<br />
Class A2S Heat Detector with flashing LED ORB-HT-51148-APO<br />
Class BR Heat Detector ORB-HT-51149-APO<br />
Class BR Heat Detector with flashing LED ORB-HT-51150-APO<br />
Class BS Heat Detector ORB-HT-51151-APO<br />
Class BS Heat Detector with flashing LED ORB-HT-51152-APO<br />
Class CR Heat Detector ORB-HT-51153-APO<br />
Class CR Heat Detector with flashing LED ORB-HT-51154-APO<br />
Class CS Heat Detector ORB-HT-51155-APO<br />
Class CS Heat Detector with flashing LED ORB-HT-51156-APO<br />
Multisensor Detector ORB-OH-53027-APO<br />
Multisensor Detector with flashing LED ORB-OH-53028-APO<br />
Optical Smoke Detector ORB-OP-52027-APO<br />
Optical Smoke Detector with flashing LED ORB-OP-52028-APO<br />
Adaptor ORB-BA-10008-APO<br />
TimeSaver Base ORB-MB-50018-APO<br />
XP95<br />
Class A2S Heat Detector 55000-400<br />
Class CS Heat Detector 55000-401<br />
Ionisation Smoke Detector 55000-500<br />
Optical Smoke Detector 55000-600<br />
Multisensor Smoke Detector 55000-885<br />
Mounting Base 45681-210<br />
Isolating Base 45681-284<br />
XP95 Interfaces<br />
Three Channel Input/Output Unit 55000-588<br />
Switch Monitor Plus 55000-841<br />
Switch Monitor 55000-843<br />
Zone Monitor 55000-845<br />
Input/Output Unit 55000-847<br />
Output Unit 55000-849<br />
Sounder Control Unit 55000-852<br />
XP95 IS<br />
Class A2S Heat Detector 55000-440<br />
Ionisation Smoke Detector 55000-540<br />
Optical Smoke Detector 55000-640<br />
Base 55000-215<br />
Manual Call Point (Red) 55000-940<br />
Discovery<br />
Heat Detector 58000-400<br />
Ionisation Smoke Detector 58000-500<br />
Isolating Base 45681-284<br />
Optical Smoke Detector 58000-600<br />
Multisensor Detector 58000-700<br />
Mounting Base 45681-210<br />
Base Sounders<br />
Integrated Base Sounder with Isolator 45681-277<br />
Integrated Base Sounder 45681-278<br />
Slow Whoop Integrated Base Sounder 45681-290<br />
with Isolator<br />
Slow Whoop Integrated Base Sounder 45681-291<br />
Integrated Base Sounder with 45681-300<br />
Short Circuit Isolator (DIN tone)<br />
Intelligent Base Sounder 45681-265<br />
Intelligent Base Sounder for Isolating Base 45681-266<br />
Intelligent Base Sounder Slow Whoop 45681-267<br />
Intelligent Base Sounder Slow Whoop 45681-268<br />
for Isolating Base<br />
Series 65 Sounder Base 45681-512<br />
Series 65 Sounder Base with Diode 45681-513<br />
Sounder Beacon<br />
Multi-Tone Open Area Sounder Beacon Red 55000-291<br />
Sounder Beacon Base with Isolator 45681-330<br />
Sounder Beacon Base 45681-331<br />
Slow Whoop Sounder Beacon Base 45681-332<br />
with Isolator<br />
Sounder Beacon Base 45681-334<br />
with Isolator (DIN Tone)<br />
Sounders<br />
100dB(A) Loop-Powered Sounder Red 55000-278<br />
100dB(A) Loop-Powered Sounder White 55000-279<br />
100dB(A) Loop-Powered Sounder 55000-276<br />
Slow Whoop Red<br />
100dB(A) Loop-Powered Sounder 55000-277<br />
Slow Whoop White<br />
Weatherproof 100dB(A) Sounder Red 55000-274<br />
Weatherproof 100dB(A) Sounder White 55000-275<br />
Approvals 127<br />
XPander<br />
XPander Optical Smoke Detector and<br />
Mounting Base XPA-CB-12034-APO<br />
XPander Multisensor Detector and<br />
Mounting Base XPA-CB-13032-APO<br />
XPander A1R Heat Detector and<br />
Mounting Base XPA-CB-11170-APO<br />
XPander CS Heat Detector and Mounting<br />
Base XPA-CB-11171-APO<br />
XPander Manual Call Point XPA-MC-14006-APO<br />
XPander Sounder and Sounder Base Red XPA-CB-14001-APO<br />
XPander Sounder and Sounder Base White XPA-CB-14002-APO<br />
XPander Sounder Beacon and Sounder<br />
Base Red XPA-CB-14003-APO<br />
XPander Sounder Beacon Amber and<br />
Sounder Base White XPA-CB-14004-APO<br />
XPander Sounder Beacon and Sounder<br />
Base White XPA-CB-14005-APO
128<br />
Approvals<br />
ATEX<br />
The ATEX directive is compulsory for all <strong>equipment</strong><br />
which is used in a hazardous area (where an explosive<br />
atmosphere might occur). The name ATEX comes from the<br />
French ATmospheres EXplosibles.<br />
Apollo products with ATEX approval:<br />
XP95 IS<br />
Ionisation Detector 55000-540<br />
Optical Smoke Detector 55000-640<br />
Heat Detector 55000-440<br />
Base 45681-215<br />
IS Standard Manual Call Points 55000-940/942/<br />
944<br />
IS MEDC Manual Call Points 55000-960/962/<br />
964/966/961/963/<br />
965/967<br />
Orbis IS<br />
Class A1R Heat Detector ORB-HT-51145-APO<br />
Class A1R Heat Detector with flashing LED ORB-HT-51146-APO<br />
Class A1S Heat Detector ORB-HT-51157-APO<br />
Class A1S Heat Detector with flashing LED ORB-HT-51158-APO<br />
Class A2S Heat Detector ORB-HT-51147-APO<br />
Class A2S Heat Detector with flashing LED ORB-HT-51148-APO<br />
Class BR Heat Detector ORB-HT-51149-APO<br />
Class BR Heat Detector with flashing LED ORB-HT-51150-APO<br />
Class BS Heat Detector ORB-HT-51151-APO<br />
Class BS Heat Detector with flashing LED ORB-HT-51152-APO<br />
Class CR Heat Detector ORB-HT-51153-APO<br />
Class CR Heat Detector with flashing LED ORB-HT-51154-APO<br />
Class CS Heat Detector ORB-HT-51155-APO<br />
Class CS Heat Detector with flashing LED ORB-HT-51156-APO<br />
Multisensor Detector ORB-OH-53027-APO<br />
Multisensor Detector with flashing LED ORB-OH-53028-APO<br />
Optical Smoke Detector ORB-OP-52027-APO<br />
Optical Smoke Detector with flashing LED ORB-OP-52028-APO<br />
TimeSaver Base ORB-MB-50018-APO
26729-152 Transparent Hinged Cover for<br />
Manual Call Point .............................................................79<br />
27249-005 Deckhead Adaptor PG16-M20 ...................................84<br />
29600-095 1.5mm Hexagonal Driver .............................................85<br />
29600-098 IS Galvanic Barrier ............................................................97<br />
29600-100 Smoke Dispenser Head ........................................... 118<br />
29600-101 Heat Detector Test Pole (240V) ............................. 118<br />
29600-102 Detector Extract Tool ................................................. 118<br />
29600-103 Extension Pole, 1.13m .............................................. 118<br />
29600-104 Telescopic Pole, 1.26m to 4.5m ............................ 118<br />
29600-110 Heat Detector Test Pole (110V) ............................ 118<br />
29600-131 Metal Deckhead Mounting Box (PG16) .................84<br />
29600-139 Metal Deckhead Mounting Box (M20)...................84<br />
29600-183 Battery Batons ............................................................. 118<br />
29600-203 Flame Detector Bracket ................................................47<br />
29600-206 Flame Detector Weathershield ..................................47<br />
29600-212 Cordless Heat Tester Kit ........................................... 118<br />
29600-213 Cordless Heat Detector Tester ............................... 118<br />
29600-214 Battery Charger ............................................................. 118<br />
29600-225 Aerosol Test Gas ......................................................... 118<br />
29600-226 Flame Sensor Test Unit and Case .......................... 117<br />
29600-235 CO Test Gas .................................................................... 118<br />
29600-239 DIN-Rail Interface Enclosure (4 units) .............. 77, 85<br />
29600-240 DIN-Rail Interface Enclosure (10 units) ........... 77, 85<br />
29600-241 Reflective Beam Detector Backbox .........................49<br />
29600-256 White Cap ...........................................................................56<br />
29600-257 Red Cap ...............................................................................56<br />
29600-318 Beacon Enclosure .............................................59, 67, 84<br />
29600-350 <strong>Fire</strong>beam Beam Detector 5-40m .............................49<br />
29600-351 <strong>Fire</strong>beam Extension Kit 40-80m ................................49<br />
29600-352 <strong>Fire</strong>beam Extension Kit 80-100m .............................49<br />
29600-353 <strong>Fire</strong>beam Adaptor Plate ................................................49<br />
29600-378 Galvanic Barier ............................................................... 100<br />
29600-449 Detector Duster ............................................................. 118<br />
29600-458 Base Mounted Flame Detector Bracket .................47<br />
29600-459 Smoke/Heat Unit .......................................................... 118<br />
29600-460 Smoke/Heat Kit ............................................................. 118<br />
29600-461 Smoke/Heat/CO Unit .................................................. 118<br />
29600-462 Smoke/Heat/CO Kit..................................................... 118<br />
29600-463 6-Pack Replacement Smoke Capsule .................. 118<br />
29600-464 3-Pack Replacement Smoke Capsule .................. 118<br />
29600-465 6-Pack Replacement CO Capsule ........................... 118<br />
29600-466 3-Pack Replacement CO Capsule ........................... 118<br />
29650-001 Magnetic Wand ................................................................67<br />
38531-771 Blank XPERT Card .............................................................23<br />
38531-822 Module Base .....................................................................83<br />
45681-200 Series 65 Standard Base ...............................................31<br />
45681-200USA Series 65A 4” Standard Base ................................... 110<br />
45681-201 Series 65 Diode Base .....................................................31<br />
45681-204 Conduit Box .......................................................................83<br />
45681-206 Series 65 Sav-Wire Base ..............................................32<br />
45681-209 Intelligent Deep Base ...............................................11,19<br />
45681-210 Intelligent Mounting Base .................................... 11, 18<br />
45681-210USA XP95A 4” Mounting Base ................................ 105,114<br />
45681-210MAR Discovery Marine Mounting Base .............................89<br />
45681-211 Isolator Base .............................................................. 12, 18<br />
45681-211USA XP95A Isolator Base ........................................... 105,114<br />
45681-211MAR Discovery Marine Isolator Base .................................89<br />
Index: Sequential Part Number List 129<br />
Index<br />
Sequential Part<br />
Number List<br />
45681-215 XP95 IS Mounting Base .................................................96<br />
45681-217 Polycarbonate Deckhead Mounting<br />
Box ...................................................................12,19, 28, 84<br />
45681-219 Intelligent Heater Base .......................................... 12, 19<br />
45681-220USA Series 65A 6” Standard Base.................................. 110<br />
45681-225USA XP95A 6” Mounting Base ................................ 105,114<br />
45681-232 Series 65A 6” Low Profile Base .............................. 110<br />
45681-233 Backplate ............................................................................83<br />
45681-235 XPERT Card Insertion Tool ........................................ 118<br />
45681-238 Series 90 to XP95 Base Adaptor ...............................85<br />
45681-242 Intelligent Low Power Relay Base .................... 12, 19<br />
45681-242UL XP95A 4” Low Power Relay Base ......................... 105<br />
45681-244 AlarmSense Base ............................................................37<br />
45681-245 Series 65 Standard Relay Base .................................32<br />
45681-246 Series 65 Auxiliary Relay Base ..................................32<br />
45681-247 Series 65 End-of-Line Relay Base (12V).................32<br />
45681-248 Series 65 End-of-Line Relay Base (24V).................32<br />
45681-250 E-Z Fit Base ............................................................. 105,114<br />
45681-251 Series 65A 6” E-Z Fit Base ......................................... 111<br />
45681-255 Series 65A 4” Standard Relay Base ...................... 110<br />
45681-256 Series 65A 4” Auxiliary Relay Base ....................... 110<br />
45681-257 Series 65A 4” 12V End-of-Line Relay Base ........ 110<br />
45681-258 Series 65A 4” 24V End-of-Line Relay Base ........ 110<br />
45681-265 Intelligent Base Sounder .............................................56<br />
45681-266 Intelligent Base Sounder for Isolating Base ...........56<br />
45681-267 Intelligent Base Sounder Slow Whoop ..................56<br />
45681-268 Intelligent Base Sounder Slow Whoop<br />
for Isolating Base .............................................................56<br />
45681-276 Ancillary Base Sounder ..................................................56<br />
45681-277 Integrated Base Sounder with Isolator ...................56<br />
45681-278 Integrated Base Sounder ..............................................56<br />
45681-284 Isolating Base ..............................................................11,18<br />
45681-290 Integrated Base Sounder - Slow Whoop<br />
with Isolator .......................................................................56
130<br />
Index: Sequential Part Number List<br />
45681-291 Integrated Base Sounder - Slow Whoop ...............56<br />
45681-292 White Cap ................................................................... 56, 65<br />
45681-293 Red Cap ....................................................................... 56, 65<br />
45681-294 AlarmSense White Cap ......................................... 57, 65<br />
45681-295 AlarmSense Red Cap ............................................. 57, 65<br />
45681-300 Integrated Base Sounder DIN-Tone with Isolator .56<br />
45681-309 Detector Ceiling Tile Mounting Box ..........................84<br />
45681-310 Sounder Ceiling Tile Mounting Box...........................84<br />
45681-311 Sounder Ceiling Plate .....................................................83<br />
45681-321 Intelligent Isolating Base ....................................... 11, 18<br />
45681-321USA XP95A Isolating Base ......................................... 105,114<br />
45681-330 Sounder Beacon Base with Isolator .........................65<br />
45681-331 Sounder Beacon Base .................................................65<br />
45681-332 Sounder Beacon Base Slow Whoop<br />
with Isolator .......................................................................65<br />
45681-333 Loop Powered Beacon Base with Isolator ............61<br />
45681-334 Sounder Beacon Base with Isolator DIN-Tone ....65<br />
45681-335 Loop-Powered Beacon Base Standard Flash .......61<br />
45681-336 Sounder Beacon Base with Australian Tone ........65<br />
45681-337 Loop-Powered Beacon Base with<br />
Australian Flash ................................................................61<br />
45681-338 Sounder Beacon Base with NZ Tone .......................65<br />
45681-340 AlarmSense Sounder Beacon Base LR ....................65<br />
45681-341 AlarmSense Sounder Base LR ...................................57<br />
45681-370 Series 65 Base Cover ....................................................83<br />
45681-380 XP95 Base Cover ............................................................83<br />
45681-393 Discovery Sounder Beacon Base ..............................65<br />
45681-508 Series 65 12V Relay Base ............................................32<br />
45681-509 AlarmSense Sounder Beacon Base ........................65<br />
45681-510 AlarmSense Sounder Base ..........................................57<br />
45681-512 Series 65 Sounder Base .............................................57<br />
45681-513 Series 65 Sounder Base with Diode ........................57<br />
45682-127 Pre-Addressed XPERT Cards........................................23<br />
53546-021 Conventional Duct Detector ........................................51<br />
53546-022 Intelligent Duct Detector ...............................................51<br />
53546-023 Orbis Duct Detector ........................................................51<br />
53832-020 Conventional Test Set ................................................. 117<br />
53832-030 Discovery Programmer .............................................. 117<br />
53832-070 MiniDisc Remote Indicator ..............12,19, 28, 33, 37<br />
55000-001 Intelligent Open-Area Sounder Red .........................54<br />
55000-002 Intelligent Open-Area Sounder White .....................54<br />
55000-005 Intelligent Open-Area Sounder Beacon Red..............<br />
Lens .......................................................................................63<br />
55000-006 Intelligent Open-Area Sounder Beacon<br />
Clear Lens ...........................................................................63<br />
55000-009 Intelligent Open-Area Beacon Red Lens ...................59<br />
55000-010 Intelligent Open-Area Beacon Clear Lens) ...............59<br />
55000-020 Intelligent IR 3 Flame Detector .....................................46<br />
55000-021 Intelligent Flameproof IR 3 Flame Detector ............46<br />
55000-022 Intelligent Base Mounted UV Flame Detector .....47<br />
55000-023 Intelligent Base Mounted UV IR² Flame Detector ..47<br />
55000-024 Intelligent Base Mounted IR 3 Flame Detector .........47<br />
55000-120 Series 65 A1R Heat Detector flashing LED<br />
and magnetic test switch ............................................31<br />
55000-121 Series 65 A1R Heat Detector ....................................31<br />
55000-122 Series 65 A1R Heat Detector Standard ..................31<br />
55000-125 Series 65 BR Heat Detector flashing LED<br />
and magnetic test switch ............................................31<br />
55000-126 Series 65 BR Heat Detector flashing LED ...............31<br />
55000-127 Series 65 BR Heat Detector Standard .....................31<br />
55000-130 Series 65 CR Heat Detector flashing LED<br />
and magnetic test switch ............................................31<br />
55000-131 Series 65 CR Heat Detector flashing LED ...............31<br />
55000-132 Series 65 CR Heat Detector Standard ......................31<br />
55000-135 Series 65 CS Heat Detector flashing LED<br />
and magnetic test switch ............................................31<br />
55000-136 Series 65 CS Heat Detector flashing LED ................31<br />
55000-137 Series 65 CS Heat Detector Standard ......................31<br />
55000-138 Series 65A 135˚F Heat Detector flashing LED<br />
and magnetic test switch ......................................... 109<br />
55000-139 Series 65A 135˚F Heat Detector flashing LED ... 109<br />
55000-140 Series 65A 135˚F Heat Detector Standard .......... 109<br />
55000-141 Series 65A 170˚F Heat Detector flashing LED<br />
and magnetic test switch ........................................ 109<br />
55000-142 Series 65A 170˚F Heat Detector flashing LED .. 109<br />
55000-143 Series 65A 170˚F Heat Detector Standard ........ 109<br />
55000-144 Series 65A 200˚F Heat Detector flashing LED<br />
and magnetic test switch ......................................... 109<br />
55000-145 Series 65A 200˚F Heat Detector flashing LED ... 109<br />
55000-146 Series 65A 200˚F Heat Detector Standard .......... 109<br />
55000-182 DIN-Rail Sounder Controller (5 Amperes)..............76<br />
55000-190 AlarmSense A1R Heat Detector (Standard) .........36<br />
55000-193 AlarmSense CS Heat Detector (High Temp) ........36<br />
55000-196 AlarmSense A1R Heat Detector and<br />
Sounder Base ....................................................................36<br />
55000-197 AlarmSense CS Heat Detector and<br />
Sounder Base ....................................................................36<br />
55000-198 AlarmSense A1R Heat Detector and<br />
Sounder Beacon Base ...................................................36<br />
55000-199 AlarmSense CS Heat Detector and<br />
Sounder Beacon Base ...................................................36<br />
55000-215 Series 65 Ionisation Smoke Detector<br />
flashing LED and magnetic test switch ...................30<br />
55000-216 Series 65 Ionisation Smoke Detector<br />
flashing LED ........................................................................30<br />
55000-217 Series 65 Ionisation Smoke Detector Standard ...30<br />
55000-218 Series 65 Integrating Ionisation Smoke<br />
Detector flashing LED and magnetic test switch ......30<br />
55000-219 Series 65 Integrating Ionisation Smoke<br />
Detector flashing LED .....................................................30<br />
55000-220 Series 65 Integrating Ionisation Smoke Detector ..30<br />
55000-225 Series 65A Ionization Smoke Detector<br />
flashing LED and magnetic test switch ................ 109<br />
55000-226 Series 65A Ionization Smoke Detector<br />
flashing LED .................................................................. 109<br />
55000-227 Series 65A Ionization Smoke Detector<br />
Standard ........................................................................... 109<br />
55000-266 XP95A Loop Powered Beam Detector ................ 104<br />
55000-268 Reflective Beam Detector (5-50m) .........................49<br />
55000-273 Reflective Beam Detector (50-100m) ....................49<br />
55000-274 Intelligent 100dB(A) Weatherproof Sounder<br />
Open-Area Red ................................................................54<br />
55000-275 Intelligent 100dB(A) Weatherproof Sounder<br />
Open-Area White ............................................................54<br />
55000-276 Intelligent 100dB(A) Open-Area Sounder<br />
Slow Whoop Red .............................................................54<br />
55000-277 Intelligent 100dB(A) Open-Area Sounder<br />
Slow Whoop White.........................................................54<br />
55000-278 Intelligent 100dB(A) Open-Area Sounder Red ....54<br />
55000-279 Intelligent 100dB(A) Open-Area Sounder<br />
White ....................................................................................54<br />
55000-280 Intelligent IR² Flame Detector .....................................46
55000-291 Multi-Tone Open Area Sounder Beacon Red .......63<br />
55000-292 Multi-Tone Open Area Sounder Beacon White ...63<br />
55000-293 Multi-Tone Open Area Sounder Beacon Red<br />
with Isolator .......................................................................63<br />
55000-294 Multi-Tone Open Area Sounder Beacon White<br />
with Isolator .......................................................................63<br />
55000-295 Flameproof Intelligent IR² Flame Detector ............46<br />
55000-296 Weatherproof Multi-Tone Open Area Sounder<br />
Beacon Red ........................................................................63<br />
55000-297 Weatherproof Multi-Tone Open Area Sounder<br />
Beacon White ...................................................................63<br />
55000-298 Weatherproof Multi-Tone Open Area Sounder<br />
Beacon Red with Isolator .............................................63<br />
55000-299 Weatherproof Multi-Tone Open Area Sounder<br />
Beacon White with Isolator .........................................63<br />
55000-315 Series 65 Optical Smoke Detector flashing<br />
LED and magnetic test switch ....................................30<br />
55000-316 Series 65 Optical Smoke Detector flashing LED 30<br />
55000-317 Series 65 Optical Smoke Detector Standard ........30<br />
55000-325 Series 65A Photo-Electric Smoke Detector<br />
flashing LED and magnetic test switch ................ 109<br />
55000-326 Series 65A Photo-Electric Smoke Detector<br />
flashing LED .................................................................. 109<br />
55000-327 Series 65A Photo-Electric Smoke Detector<br />
Standard ........................................................................... 109<br />
55000-390 AlarmSense Optical Smoke Detector ......................36<br />
55000-391 AlarmSense Integrating Optical Smoke<br />
Detector ..............................................................................36<br />
55000-392 AlarmSense Optical Smoke Detector and<br />
Sounder Base ....................................................................36<br />
55000-393 AlarmSense Integrating Optical Smoke<br />
Detector and Sounder Base ........................................36<br />
55000-394 AlarmSense Optical Smoke Detector and<br />
Sounder Beacon Base ...................................................36<br />
55000-395 AlarmSense Integrating Optical Smoke<br />
Detector and Sounder Beacon Base ........................36<br />
55000-400 XP95 Heat Detector A2S ..............................................17<br />
55000-401 XP95 Heat Detector CS .................................................17<br />
55000-440 XP95 IS Heat Detector ...................................................96<br />
55000-450 XP95A Heat Detector ................................................. 104<br />
55000-500 XP95 Ionisation Smoke Detector ..............................17<br />
55000-540 XP95 IS Ionisation Smoke Detector..........................96<br />
55000-550 XP95A Ionization Smoke Detector ........................ 104<br />
55000-588 Three Channel Input/Output Unit ..............................70<br />
55000-600 XP95 Optical Smoke Detector ....................................17<br />
55000-640 XP95 IS Optical Smoke Detector ...............................96<br />
55000-650 XP95A Photo-Electric Smoke Detector ................ 104<br />
55000-700MAR Discovery Marine Isolator .............................................89<br />
55000-720 Isolator ...........................................................................11,18<br />
55000-750 XP95A Isolator ..................................................... 105,114<br />
55000-760 Mini Switch Monitor ............................................... 74, 77<br />
55000-765 Mini Monitor Module .................................................. 106<br />
55000-790 XP95A Dual Priority Switch Monitor Module ..... 107<br />
55000-802 DIN-Rail Dual Isolator ......................................................77<br />
55000-803 DIN-Rail Input/Output Unit ...........................................76<br />
55000-804 DIN-Rail Output Unit .......................................................76<br />
55000-805 XP95A Switch Monitor Module .............................. 106<br />
55000-806USA XP95A Priority Switch Monitor Module ............... 107<br />
55000-812 DIN-Rail Zone Monitor with Isolator .........................77<br />
55000-820USA XP95A Switch Monitor Input/Output Module ... 107<br />
55000-821 DIN-Rail Switch Monitor Plus ......................................77<br />
Index: Sequential Part Number List 131<br />
55000-822 DIN-Rail Switch Monitor ................................................76<br />
55000-825 XP95A Sounder Control Module ............................. 107<br />
55000-826 DIN-Rail Sounder Control Unit .....................................80<br />
55000-830 XP95A Mini Priority Switch Monitor Module ..... 106<br />
55000-831 XP95A Mini Switch Monitor Module .................... 106<br />
55000-832 Mini Switch Monitor with fly leads (Interrupt).....74<br />
55000-833 Mini Switch Monitor with fly leads ...........................74<br />
55000-835 AlarmSense Alarm Relay ............................................37<br />
55000-841 Switch Monitor Plus ........................................................71<br />
55000-843 Switch Monitor .................................................................71<br />
55000-845 Zone Monitor Unit ...........................................................71<br />
55000-847 Input/Output Unit ............................................................70<br />
55000-849 Output Unit .........................................................................70<br />
55000-852 Sounder Control Unit ......................................................70<br />
55000-855 XP95 Protocol Translator (Single Channel) ............97<br />
55000-856 XP95 Protocol Translator (Dual Channel) ...............97<br />
55000-863 XP95A Relay Output Module ................................... 107<br />
55000-870 XP95 Test Set ................................................................. 117<br />
55000-872 Printer for XP95 Test Set ........................................... 117<br />
55000-875 Mains Switching Input/Output Unit ..........................71<br />
55000-877 Loop-Powered Beacon Red ........................................59<br />
55000-878 Loop-Powered Beacon Clear Lens Red Flash .......59<br />
55000-879 Loop-Powered Beacon Amber ..................................59<br />
55000-885 XP95 Multisensor Detector ..........................................17<br />
55000-886 XP95A Multisensor Detector ................................... 104<br />
55000-894 AlarmSense Manual Call Point (Surface) ...............80<br />
55100-940 XP95 IS Manual Call Point Without Flap - Red ......96<br />
55100-942 XP95 IS Manual Call Point Without Flap - Yellow ..96<br />
55100-944 XP95 IS Manual Call Point Without Flap -<br />
Blue/White .........................................................................96<br />
55000-945 XP95 IS Manual Call Point With Flap -<br />
Blue/White .........................................................................96<br />
55000-960 XP95 IS Manual Call Point MEDC Break<br />
Glass - Red .........................................................................97<br />
55000-961 XP95 IS Manual Call Point MEDC Break<br />
Glass with flap - Red ......................................................97<br />
55000-962 XP95 IS Manual Call Point MEDC Break<br />
Glass - Yellow ...................................................................97<br />
55000-963 XP95 IS Manual Call Point MEDC Break<br />
Glass with flap - Yellow ................................................97<br />
55000-964 XP95 IS Manual Call Point MEDC Break<br />
Glass - Blue ........................................................................97<br />
55000-965 XP95 IS Manual Call Point MEDC Break<br />
Glass with flap - Blue .....................................................97<br />
55000-966 XP95 IS Manual Call Point MEDC Break<br />
Glass - Black/Yellow Stripes ........................................97<br />
55000-967 XP95 IS Manual Call Point MEDC Break<br />
Glass with flap - Black/Yellow Stripes ....................97<br />
55000-970 XP95 IS Manual Call Point MEDC Push<br />
Button - Red ......................................................................97<br />
55000-971 XP95 IS Manual Call Point MEDC Push<br />
Button - Yellow ................................................................97<br />
55000-972 XP95 IS Manual Call Point MEDC Push<br />
Button - Blue .....................................................................97<br />
55000-973 XP95 IS Manual Call Point MEDC Push<br />
Button - Black/Yellow Stripes.....................................97<br />
55100-905 XP95 Manual Call Point - Red (Surface) .................79<br />
55100-908 XP95 Manual Call Point with Isolator - Red<br />
(Surface) .............................................................................79<br />
58000-300 Discovery CO <strong>Fire</strong> Detector..........................................10<br />
58000-400 Discovery Heat Detector ..............................................10
132<br />
Index: Sequential Part Number List<br />
58000-400MAR Discovery Marine Heat Detector ...............................88<br />
58000-450 Discovery UL Heat Detector .................................... 113<br />
58000-500 Discovery Ionisation Smoke Detector .....................10<br />
58000-500MAR Discovery Marine Ionisation Smoke Detector .....88<br />
58000-550 Discovery UL Ionization Smoke Detector ............ 113<br />
58000-600 Discovery Optical Smoke Detector...........................10<br />
58000-600MAR Discovery Marine Optical Smoke Detector ...........88<br />
58000-650 Discovery UL Photo-Electric Smoke Detector ... 113<br />
58000-700 Discovery Multisensor Detector ................................10<br />
58000-700MAR Discovery Marine Multisensor ....................................88<br />
55000-797 DIN-Rail Mains Input/Output Unit .............................76<br />
58000-750 Discovery UL Multisensor Detector ....................... 113<br />
58100-908 Discovery Manual Call Point with Isolator -<br />
Red (Surface) ....................................................................79<br />
58100-910 Discovery Manual Call Point - Red (Surface) ........79<br />
51800-920 Discovery Manual Call Point (non standard)<br />
White ...................................................................................79<br />
51800-927 Discovery Manual Call Point (non standard)<br />
Yellow ..................................................................................79<br />
58100-928 Discovery Manual Call Point (non standard)<br />
Blue .......................................................................................79<br />
58100-929 Discovery Manual Call Point (non standard)<br />
Green ...................................................................................79<br />
58100-950 Waterproof Manual Call Point - Red ........................80<br />
58100-951 Waterproof Manual Call Point with Isolator -<br />
Red ........................................................................................80<br />
58100-970MAR Discovery Marine Manual Call Point .......................89<br />
ORB-BA-10008-APO S65 to Orbis Base Adaptor ..........................................85<br />
ORB-BA-50008-APO Orbis IS Adaptor ............................................................ 100<br />
ORB-DB-00003-APO TimeSaver Diode Base ..................................................27<br />
ORB-HB-00020-APO Orbis Heater Base ...........................................................28<br />
ORB-HT-11001-APO Orbis A1R Heat Detector Standard ...........................26<br />
ORB-HT-11002-APO Orbis A2S Heat Detector Standard ...........................26<br />
ORB-HT-11003-APO Orbis BR Heat Detector Standard ..............................26<br />
ORB-HT-11004-APO Orbis BS Heat Detector Standard ..............................26<br />
ORB-HT-11005-APO Orbis CR Heat Detector Standard ..............................26<br />
ORB-HT-11006-APO Orbis CS Heat Detector Standard ..............................26<br />
ORB-HT-11013-APO Orbis A1R Heat Detector with flashing LED ..........26<br />
ORB-HT-11014-APO Orbis A2S Heat Detector with flashing LED ..........26<br />
ORB-HT-11015-APO Orbis BR Heat Detector with flashing LED .............26<br />
ORB-HT-11016-APO Orbis BS Heat Detector with flashing LED .............26<br />
ORB-HT-11017-APO Orbis CR Heat Detector with flashing LED .............26<br />
ORB-HT-11018-APO Orbis CS Heat Detector with flashing LED ..............26<br />
ORB-HT-11166-APO Orbis A1S Heat Detector ..............................................26<br />
ORB-HT-11167-APO Orbis A1S Heat Detector with flashing LED ..........26<br />
ORB-HT-41001-MAR Orbis Marine A1R Heat Detector ...............................91<br />
ORB-HT-41002-MAR Orbis Marine A2S Heat Detector ...............................91<br />
ORB-HT-41003-MAR Orbis Marine BR Heat Detector ..................................91<br />
ORB-HT-41004-MAR Orbis Marine BS Heat Detector ..................................91<br />
ORB-HT-41005-MAR Orbis Marine CR Heat Detector ..................................91<br />
ORB-HT-41006-MAR Orbis Marine CS Heat Detector ..................................91<br />
ORB-HT-41013-MAR Orbis Marine A1R Heat Detector with<br />
flashing LED ........................................................................91<br />
ORB-HT-41014-MAR Orbis Marine A2S Heat Detector with<br />
flashing LED ........................................................................91<br />
ORB-HT-41015-MAR Orbis Marine BR Heat Detector with<br />
flashing LED ........................................................................91<br />
ORB-HT-41016-MAR Orbis Marine BS Heat Detector with<br />
flashing LED ........................................................................91<br />
ORB-HT-41017-MAR Orbis Marine CR Heat Detector with<br />
flashing LED ........................................................................91<br />
ORB-HT-41018-MAR Orbis Marine CS Heat Detector with<br />
flashing LED ........................................................................91<br />
ORB-HT-51145-APO Orbis IS A1R Heat Detector .........................................99<br />
ORB-HT-51146-APO Orbis IS A1R Heat Detector with flashing LED......99<br />
ORB-HT-51147-APO Orbis IS A2S Heat Detector ..........................................99<br />
ORB-HT-51148-APO Orbis IS A2S Heat Detector with flashing LED ......99<br />
ORB-HT-51149-APO Orbis IS BR Heat Detector ............................................99<br />
ORB-HT-51150-APO Orbis IS BR Heat Detector with flashing LED ........99<br />
ORB-HT-51151-APO Orbis IS BS Heat Detector .............................................99<br />
ORB-HT-51152-APO Orbis IS BS Heat Detector with flashing LED .........99<br />
ORB-HT-51153-APO Orbis IS CR Heat Detector .............................................99<br />
ORB-HT-51154-APO Orbis IS CR Heat Detector with flashing LED .........99<br />
ORB-HT-51155-APO Orbis IS CS Heat Detector .............................................99<br />
ORB-HT-51156-APO Orbis IS CS Heat Detector with flashing LED .........99<br />
ORB-HT-51157-APO Orbis IS A1S Heat Detector ..........................................99<br />
ORB-HT-51158-APO Orbis IS A1S Heat Detector with flashing LED ......99<br />
ORB-MB 50018-APO Orbis IS Timesaver Base ........................................... 100<br />
ORB-MB-00001-APO TimeSaver Base ...............................................................27<br />
ORB-MB-00002-APO TimeSaver LX Base .........................................................27<br />
ORB-MB-00012-APO Orbis LX Base ....................................................................27<br />
ORB-MB-00019-APO TimeSaver Deep Base ...................................................28<br />
ORB-MB-00001-MAR Orbis Marine TimeSaver Base ....................................92<br />
ORB-OH-13001-APO Orbis Multisensor Detector ..........................................26<br />
ORB-OH-13003-APO Orbis Multisensor Detector with<br />
flashing LED ........................................................................26<br />
ORB-OH-43001-MAR Orbis Marine Multisensor Detector ..........................91<br />
ORB-OH-43003-MAR Orbis Marine Multisensor Detector<br />
with flashing LED ............................................................91<br />
ORB-OH-53027-APO Orbis IS Multisensor Detector .....................................99<br />
ORB-OH-53028-APO Orbis IS Multisensor with flashing LED ....................99<br />
ORB-OP-12001-APO Orbis Optical Smoke Detector ....................................26<br />
ORB-OP-12003-APO Orbis Optical Smoke Detector with<br />
flashing LED ........................................................................26<br />
ORB-OP-42001-MAR Orbis Marine Optical Smoke Detector ....................91<br />
ORB-OP-42003-MAR Orbis Marine Optical Smoke Detector<br />
with flashing LED .............................................................91<br />
ORB-OP-52027-APO Orbis IS Optical Smoke Detector ...............................99<br />
ORB-OP-52028-APO Orbis IS Optical Smoke Detector with<br />
flashing LED ........................................................................99<br />
ORB-RB-10004-APO TimeSaver Relay Base ...................................................27<br />
ORB-RB-40004-MAR Orbis Marine Relay Base...............................................92<br />
ORB-SW-10005-APO Sav-Wire Base ..................................................................29<br />
XPA-CB-11170-APO XPander A1R Heat Detector and Mounting Base..42<br />
XPA-CB-11171-APO XPander CS Heat Detector and Mounting Base ..42<br />
XPA-CB-12034-APO XPander Optical Smoke Detector and<br />
Mounting Base .................................................................42<br />
XPA-CB-13032-APO XPander Multisensor Detector and<br />
Mounting Base .................................................................42<br />
XPA-CB-14001-APO XPander Sounder and Sounder Base Red .............89<br />
XPA-CB-14002-APO XPander Sounder and Sounder Base White .........89<br />
XPA-CB-14003-APO XPander Red Sounder Beacon and Red<br />
Sounder Base ....................................................................63<br />
XPA-CB-14004-APO XPander Amber Sounder Beacon and<br />
White Sounder Base .......................................................63<br />
XPA-CB-14005-APO XPander Clear Sounder Beacon and<br />
White Sounder Base .......................................................63<br />
XPA-IN-14007-APO XPander Interface Unit ..................................................43<br />
XPA-MC-14006-APO XPander Manual Call Point ...........................................80<br />
XPA-TE-14010-APO XPander Survey Tool ......................................................43
AlarmSense 35<br />
AlarmSense Alarm Relay ..........................................55000-835 ........................37<br />
AlarmSense A1R Heat Detector (Standard) .......55000-190 ........................36<br />
AlarmSense A1R Heat Detector and<br />
Sounder Base..................................................................55000-196 ........................36<br />
AlarmSense A1R Heat Detector and<br />
Sounder Beacon Base .................................................55000-198 ........................36<br />
AlarmSense Base ..........................................................45681-244 ........................37<br />
AlarmSense CS Heat Detector (High Temp) ......55000-193 ........................36<br />
AlarmSense CS Heat Detector and<br />
Sounder Base..................................................................55000-197 ........................36<br />
AlarmSense CS Heat Detector and<br />
Sounder Beacon Base .................................................55000-199 ........................36<br />
AlarmSense Integrating Optical<br />
Smoke Detector ............................................................55000-391 ........................36<br />
AlarmSense Integrating Optical<br />
Smoke Detector and Sounder Base ......................55000-393 ........................36<br />
AlarmSense Integrating Optical<br />
Smoke Detector and Sounder Beacon Base ......55000-395 ........................36<br />
AlarmSense Manual Call Point (Flush) ..................55000-893 ........................80<br />
AlarmSense Manual Call Point (Surface) .............55000-894 ........................80<br />
AlarmSense Optical Smoke Detector ...................55000-390 ........................36<br />
AlarmSense Optical Smoke Detector<br />
and Sounder Base .........................................................55000-392 ........................36<br />
AlarmSense Optical Smoke Detector<br />
and Sounder Beacon Base ........................................55000-394 ........................36<br />
AlarmSense Red Cap ...................................................45681-295 ................ 57, 65<br />
AlarmSense Sounder Base ........................................45681-510 ........................57<br />
AlarmSense Sounder Base LR ................................45681-341 ........................57<br />
AlarmSense Sounder Beacon Base ......................45681-509 ........................65<br />
AlarmSense Sounder Beacon Base LR .................45681-340 ........................65<br />
AlarmSense White Cap ...............................................45681-294 ................ 57, 65<br />
AV Accessories 66<br />
Beacon Enclosure ..........................................................29600-318 ........................67<br />
Magnetic Wand .............................................................29650-001 ........................67<br />
Base Sounders 55<br />
AlarmSense Sounder Base ........................................45681-510 ........................57<br />
AlarmSense Sounder Base LR ................................45681-341 ........................57<br />
Ancillary Base Sounder ...............................................45681-276 ........................56<br />
Integrated Base Sounder ...........................................45681-278 ........................56<br />
Integrated Base Sounder - Slow Whoop .............45681-291 ........................56<br />
Integrated Base Sounder - Slow Whoop<br />
with Isolator ....................................................................45681-290 ........................56<br />
Integrated Base Sounder DIN-tone<br />
with Isolator ....................................................................45681-300 ........................56<br />
Integrated Base Sounder with Isolator .................45681-277 ........................56<br />
Intelligent Base Sounder ...........................................45681-265 ........................56<br />
Intelligent Base Sounder for Isolating Base ........45681-266 ........................56<br />
Intelligent Base Sounder Slow Whoop ................45681-267 ........................56<br />
Intelligent Base Sounder Slow Whoop<br />
for Isolating Base ...........................................................45681-268 ........................56<br />
Red Cap (for Intelligent Base Sounder) ................29600-257 ........................56<br />
Red Cap (for Integrated Base Sounder) ...............45681-293 ........................56<br />
Series 65 Sounder Base ...........................................45681-512 ........................57<br />
Index<br />
Product<br />
Index: Product 133<br />
Series 65 Sounder Base with Diode ......................45681-513 ........................57<br />
White Cap (for Intelligent Base Sounder) ............26900-256 ........................56<br />
White Cap (for Integrated Base Sounder) ...........45681-292 ........................56<br />
Beacon Bases 60<br />
Loop-Powered Beacon Base with Isolator .........45681-333 ........................61<br />
Loop-Powered Beacon Base ....................................45681-335 ........................61<br />
Loop-Powered Beacon Base with<br />
Australian Flash ..............................................................45681-337 ........................61<br />
Red Cap .............................................................................45681-293 ........................61<br />
White Cap .........................................................................45681-292 ........................61<br />
Beacons 58<br />
Beacon Enclosure ..........................................................29600-318 ........................59<br />
Intelligent Open-Area Beacon Red Lens ..................55000-009 ........................59<br />
Intelligent Open-Area Beacon Clear Lens ..................55000-010 ........................59<br />
Loop-Powered Beacon Amber ...............................55000-879 ........................59<br />
Loop-Powered Beacon Clear Lens Red Flash ....55000-878 ........................59<br />
Loop-Powered Beacon Red ......................................55000-877 ........................59<br />
DIN-Rail Interfaces 75<br />
DIN-Rail Dual Isolator ...................................................55000-802 ........................77<br />
DIN-Rail Input/Output Unit.........................................55000-803 ........................76<br />
DIN-Rail Interface Enclosure (10 units) .................29600-240 ................ 77, 85<br />
DIN-Rail Interface Enclosure (4 units)....................29600-239 ................ 77, 85<br />
DIN-Rail Mains Input/Output Unit ...........................55000-797 ........................76<br />
DIN-Rail Output Unit .....................................................55000-804 ........................76<br />
DIN-Rail Sounder Controller (5 Amperes) ...........55000-182 ........................76
134<br />
Index: Product<br />
DIN-Rail Switch Monitor .............................................55000-822 ........................76<br />
DIN-Rail Switch Monitor Plus ....................................55000-821 ........................77<br />
DIN-Rail Zone Monitor with Isolator.......................55000-812 ........................77<br />
Mini Switch Monitor .....................................................55000-760 ........................77<br />
Discovery 9<br />
Discovery Carbon Monoxide <strong>Fire</strong> Detector .........58000-300 ........................10<br />
Discovery Heat Detector ............................................58000-400 ........................10<br />
Discovery Ionisation Smoke Detector ...................58000-500 ........................10<br />
Discovery Manual Call Point (non standard)<br />
White..................................................................................51800-920 ........................79<br />
Discovery Manual Call Point<br />
(non standard) Yellow ................................................51800-927 ........................79<br />
Discovery Manual Call Point<br />
(non standard) Blue .....................................................58100-928 ........................79<br />
Discovery Manual Call Point<br />
(non standard) Green..................................................58100-929 ........................79<br />
Discovery Manual Call Point - Red (Surface) ......58100-910 ........................79<br />
Discovery Manual Call Point with Isolator -<br />
Red (Surface) ..................................................................58100-908 ........................79<br />
Discovery Multisensor Detector ..............................58000-700 ........................10<br />
Discovery Optical Smoke Detector ........................58000-600 ........................10<br />
Discovery Programmer ..............................................53832-030 ..................... 117<br />
Discovery Sounder Beacon Base ............................45681-393 ........................65<br />
Intelligent Deep Base ..................................................45681-209 ........................11<br />
Isolator ...............................................................................55000-720 ........................11<br />
Intelligent Mounting Base ..........................................45681-210 ........................11<br />
Isolating Base ..................................................................45681-284 ........................11<br />
MiniDisc Remote Indicator.........................................53830-070 ........................12<br />
Discovery Marine 87<br />
Discovery Marine Heat Detector ............................58000-400MAR ..............88<br />
Discovery Marine Ionisation Smoke Detector ...58000-500MAR ..............88<br />
Discovery Marine Isolator ..........................................55000-700MAR ..............88<br />
Discovery Marine Isolator Base ...............................45681-211MAR ..............89<br />
Discovery Marine Manual Call Point .....................58100-970MAR ..............89<br />
Discovery Marine Mounting Base ..........................45681-210MAR ..............89<br />
Discovery Marine Multisensor .................................58000-700MAR ..............88<br />
Discovery Marine Optical Smoke Detector .........58000-600MAR ..............88<br />
Discovery UL 112<br />
Discovery UL Heat Detector ....................................58000-450 ..................... 113<br />
Discovery UL Ionization Smoke Detector ............58000-550 ..................... 113<br />
Discovery UL Multisensor Detector ........................58000-750 ..................... 113<br />
Discovery UL Photo-Electric Smoke Detector ....58000-650 ..................... 113<br />
XP95A Isolating Base ...................................................45681-321USA ............. 114<br />
XP95A 4” Mounting Base ..........................................45681-210USA ............. 114<br />
XP95A 6” Mounting Base ..........................................45681-225USA ............. 114<br />
XP95A E-Z Fit Base .......................................................45681-250 ..................... 114<br />
XP95A Isolator ...............................................................55000-750 ..................... 114<br />
XP95A Isolator Base .....................................................45681-211USA ............. 114<br />
Manual Call Points 78<br />
AlarmSense Manual Call Point (Flush) ..................55000-893 ........................80<br />
AlarmSense Manual Call Point (Surface) .............55000-894 ........................80<br />
Discovery Manual Call Point - Red (Surface) ......58100-910 ........................79<br />
Discovery Manual Call Point with Isolator -<br />
Red (Surface) ..................................................................58100-908 ........................79<br />
Transparent Hinged Cover for Manual<br />
Call Point ...........................................................................26729-152 ........................79<br />
Waterproof Manual Call Point - Red ......................58100-950 ........................80<br />
Waterproof Manual Call Point with<br />
Isolator - Red ...................................................................58100-951 ........................80<br />
XP95 Manual Call Point - Red (Surface) ...............55100-905 ........................79<br />
XP95 Manual Call Point with Isolator -<br />
Red (Surface) ..................................................................55100-908 ........................79<br />
XPander Manual Call Point ........................................XPA-MC-14006-APO .....80<br />
Mini Interfaces 73<br />
Mini Switch Monitor .....................................................55000-760 ........................74<br />
XP95 Mini Switch Monitor with fly leads ............55000-833 ........................74<br />
XP95 Mini Switch Monitor with fly leads<br />
(Interrupt) .........................................................................55000-832 ........................74<br />
Mounting Accessories 82<br />
1.5mm Hexagonal Driver ..........................................29600-095 ........................85<br />
Backplate ..........................................................................45681-233 ........................83<br />
Beacon Enclosure ..........................................................29600-318 ........................84<br />
Conduit Box .....................................................................45681-204 ........................83<br />
Deckhead Adaptor PG16-M20 ................................27249-005 ........................84<br />
Detector Ceiling Tile Mounting Box .......................45681-309 ........................84<br />
DIN-Rail Interface Enclosure (10 units) .................29600-240 ........................85<br />
DIN-Rail Interface Enclosure (4 units)....................29600-239 ........................85<br />
Metal Deckhead Mounting Box (M20) ................29600-139 ........................84<br />
Metal Deckhead Mounting Box (PG16) ...............29600-131 ........................84<br />
Module Base ...................................................................38531-822 ........................83<br />
Polycarbonate Deckhead Mounting Box .............45681-217 ........................84<br />
Series 65 to Orbis Base Adaptor .............................ORB-BA-10008-APO .....85<br />
Series 90 to XP95 Base Adaptor .............................45681-238 ........................85<br />
Series 65 Base Cover .................................................45681-370 ........................83<br />
Sounder Ceiling Plate ...................................................45681-311 ........................83<br />
Sounder Ceiling Tile Mounting Box ........................45681-310 ........................87<br />
XP95 Base Cover .........................................................45681-380 ........................83<br />
Orbis 25<br />
MiniDisc Remote Indicator.........................................53832-070 ........................28<br />
Orbis A1R Heat Detector ............................................ORB-HT-11001-APO ......26<br />
Orbis A1R Heat Detector with flashing LED ........ORB-HT-11013-APO ......26<br />
Orbis A1S Heat Detector ............................................ORB-HT-11166-APO ......26<br />
Orbis A1S Heat Detector with flashing LED ........ORB-HT-11167-APO ......26<br />
Orbis A2S Heat Detector ............................................ORB-HT-11002-APO ......26<br />
Orbis A2S Heat Detector with flashing LED ........ORB-HT-11014-APO ......26<br />
Orbis BR Heat Detector ...............................................ORB-HT-11003-APO ......26<br />
Orbis BR Heat Detector with flashing LED ...........ORB-HT-11015-APO ......26<br />
Orbis BS Heat Detector ...............................................ORB-HT-11004-APO ......26<br />
Orbis BS Heat Detector with flashing LED ...........ORB-HT-11016-APO ......26<br />
Orbis CR Heat Detector ...............................................ORB-HT-11005-APO ......26<br />
Orbis CR Heat Detector with flashing LED ...........ORB-HT-11017-APO ......26<br />
Orbis CS Heat Detector ...............................................ORB-HT-11006-APO ......26<br />
Orbis CS Heat Detector with flashing LED ...........ORB-HT-11018-APO ......26
Orbis LX Base ..................................................................ORB-MB-00012-APO ....27<br />
Orbis Duct Detector ......................................................53546-023 ........................51<br />
Orbis Heater Base .........................................................ORB-HB-00020-APO .....28<br />
Orbis Multisensor Detector .......................................ORB-OH-13001-APO .....26<br />
Orbis Multisensor Detector with<br />
flashing LED .....................................................................ORB-OH-13003-APO .....26<br />
Orbis Optical Smoke Detector ..................................ORB-OP-12001-APO .....26<br />
Orbis Optical Smoke Detector with<br />
flashing LED .....................................................................ORB-OP-12003-APO .....26<br />
TimeSaver Base .............................................................ORB-MB-00001-APO ....27<br />
TimeSaver Deep Base .................................................ORB-MB-00019-APO ....28<br />
TimeSaver Diode Base ................................................ORB-DB-00003-APO .....27<br />
TimeSaver LX Base .......................................................ORB-MB-00002-APO ....27<br />
TimeSaver Relay Base ................................................ORB-RB-10004-APO ......27<br />
Sav-Wire Base ................................................................ORB-SW-10005-APO ....28<br />
Polycarbonate Deckhead Mounting Box .............45681-217 ........................84<br />
Waterproof Base Cover ..............................................45681-519 ........................28<br />
Orbis IS 98<br />
Galvanic Barrier ..............................................................29600-378 ..................... 100<br />
Orbis IS A1R Heat Detector .......................................ORB-HT-51145-APO ......99<br />
Orbis IS A1R Heat Detector with flashing LED .....ORB-HT-51146-APO ......99<br />
Orbis IS A1S Heat Detector .......................................ORB-HT-51157-APO ......99<br />
Orbis IS A1S Heat Detector with flashing LED ......ORB-HT-51158-APO .......99<br />
Orbis IS A2S Heat Detector ...........................................ORB-HT-51147-APO .......99<br />
Orbis IS A2S Heat Detector with flashing LED ......ORB-HT-51148-APO .......99<br />
Orbis IS Adaptor .................................................................ORB-BA-50008-APO ...100<br />
Orbis IS BR Heat Detector ..............................................ORB-HT-51149-APO .......99<br />
Orbis IS BR Heat Detector with flashing LED .........ORB-HT-51150-APO .......99<br />
Orbis IS BS Heat Detector ..............................................ORB-HT-51151-APO .......99<br />
Orbis IS BS Heat Detector with flashing LED .........ORB-HT-51152-APO .......99<br />
Orbis IS CR Heat Detector ..............................................ORB-HT-51153-APO .......99<br />
Orbis IS CR Heat Detector with flashing LED .........ORB-HT-51154-APO .......99<br />
Orbis IS CS Heat Detector ..............................................ORB-HT-51155-APO .......99<br />
Orbis IS CS Heat Detector with flashing LED .........ORB-HT-51156-APO .......99<br />
Orbis IS Multisensor Detector ...................................ORB-OH-53027-APO .....99<br />
Orbis IS Multisensor with flashing LED ..................ORB-OH-53028-APO .....99<br />
Orbis IS Optical Smoke Detector .............................ORB-OP-52027-APO .....99<br />
Orbis IS Optical Smoke Detector with<br />
flashing LED .....................................................................ORB-OP-52028-APO .....99<br />
Orbis IS Timesaver IS Base .......................................ORB-MB-50018-APO .100<br />
Orbis Marine 90<br />
Orbis Marine A1R Heat Detector ............................ORB-HT-41001-MAR .....91<br />
Orbis Marine A1R Heat Detector with<br />
flashing LED .....................................................................ORB-HT-41013-MAR .....91<br />
Orbis Marine A2S Heat Detector ............................ORB-HT-41002-MAR .....91<br />
Orbis Marine A2S Heat Detector with<br />
flashing LED .....................................................................ORB-HT-41014-MAR .....91<br />
Orbis Marine BR Heat Detector ...............................ORB-HT-41003-MAR .....91<br />
Orbis Marine BR Heat Detector with<br />
flashing LED .....................................................................ORB-HT-41015-MAR .....91<br />
Orbis Marine BS Heat Detector ...............................ORB-HT-41004-MAR .....91<br />
Orbis Marine BS Heat Detector with<br />
flashing LED .....................................................................ORB-HT-41016-MAR .....91<br />
Index: Product 135<br />
Orbis Marine CR Heat Detector ...............................ORB-HT-41005-MAR .....91<br />
Orbis Marine CR Heat Detector with<br />
flashing LED .....................................................................ORB-HT-41017-MAR .....91<br />
Orbis Marine CS Heat Detector ................................ORB-HT-41006-MAR .....91<br />
Orbis Marine CS Heat Detector with<br />
flashing LED .....................................................................ORB-HT-41018-MAR .....91<br />
Orbis Marine Multisensor Detector ........................ORB-OH-43001-MAR ....91<br />
Orbis Marine Optical Smoke Detector ..................ORB-OP-42001-MAR ....91<br />
Orbis Marine Relay Base ............................................ORB-RB-40004-MAR .....92<br />
Orbis Marine TimeSaver Base ..................................ORB-MB-00001-MAR ...92<br />
Orbis Marine Multisensor Detector with<br />
flashing LED .....................................................................ORB-OH-43003-MAR ....91<br />
Orbis Marine Optical Smoke Detector<br />
with flashing LED ...........................................................ORB-OP-42003-MAR ....91<br />
Series 65A 108<br />
Series 65A 135˚F Heat Detector flashing LED ......55000-139 ..................... 109<br />
Series 65A 135˚F Heat Detector flashing LED<br />
and magnetic test switch ..........................................55000-138 ..................... 109<br />
Series 65A 135˚F Heat Detector Standard ..........55000-140 ..................... 109<br />
Series 65A 170˚F Heat Detector flashing LED ......55000-142 ..................... 109<br />
Series 65A 170˚F Heat Detector flashing LED<br />
and magnetic test switch ..........................................55000-141 ..................... 109<br />
Series 65A 170˚F Heat Detector Standard ..........55000-143 ..................... 109<br />
Series 65A 200˚F Heat Detector flashing LED ......55000-145 ..................... 109<br />
Series 65A 200˚F Heat Detector flashing LED<br />
and magnetic test switch ..........................................55000-144 ..................... 109<br />
Series 65A 200˚F Heat Detector Standard ..........55000-146 ..................... 109<br />
Series 65A 4” 12V End-of-Line Relay Base .........45681-257 ..................... 110<br />
Series 65A 4” 24V End-of-Line Relay Base .........45681-258 ..................... 110<br />
Series 65A 4” Auxiliary Relay Base ........................45681-256 ..................... 110<br />
Series 65A 4” Standard Base ...................................45681-200USA ............. 110<br />
Series 65A 4” Standard Relay Base .......................45681-255 ..................... 110<br />
Series 65A 6” E-Z Fit Base .........................................45681-251 ..................... 111<br />
Series 65A 6” Low Profile Base ...............................45681-232 ..................... 110<br />
Series 65A 6” Standard Base ...................................45681-220USA ............. 110<br />
Series 65A Ionization Smoke Detector<br />
flashing LED ...................................................................55000-226 ..................... 109<br />
Series 65A Ionization Smoke Detector<br />
flashing LED and magnetic test switch ................55000-225 ..................... 109<br />
Series 65A Ionization Smoke Detector<br />
Standard ...........................................................................55000-227 ..................... 109<br />
Series 65A Photo-Electric Smoke Detector<br />
flashing LED ...................................................................55000-326 ..................... 109<br />
Series 65A Photo-Electric Smoke Detector<br />
flashing LED and magnetic test switch ................55000-325 ..................... 109<br />
Series 65A Photo-Electric Smoke Detector<br />
Standard ...........................................................................55000-327 ..................... 109<br />
Series 65 29<br />
MiniDisc Remote Indicator.........................................53832-070 ........................33<br />
Series 65 12V Relay Base ..........................................45681-508 ........................31<br />
Series 65 Auxiliary Relay Base ...............................45681-246 ........................31<br />
Series 65 Base Cover .................................................45681-370 ........................83<br />
Series 65 Diode Base ...................................................45681-201 ........................31
136<br />
Index: Product<br />
Series 65 End-of-Line Relay Base (12V) ..............45681-247 ........................32<br />
Series 65 End-of-Line Relay Base (24V) ..............45681-248 ........................32<br />
Series 65 Sav-Wire Base ............................................45681-206 ........................32<br />
Series 65 Standard Base ............................................45681-200 ........................31<br />
Series 65 A1R Heat Detector flashing LED ..........55000-121 ........................31<br />
Series 65 A1R Heat Detector flashing LED<br />
and magnetic test switch ..........................................55000-120 ........................31<br />
Series 65 A1R Heat Detector Standard ................55000-122 ........................31<br />
Series 65 BR Heat Detector flashing LED ..........55000-126 ........................31<br />
Series 65 BR Heat Detector flashing LED<br />
and magnetic test switch ..........................................55000-125 ........................31<br />
Series 65 BR Heat Detector Standard ...................55000-127 ........................31<br />
Series 65 CR Heat Detector flashing LED ..........55000-131 ........................31<br />
Series 65 CR Heat Detector flashing LED<br />
and magnetic test switch ..........................................55000-130 ........................31<br />
Series 65 CR Heat Detector Standard ...................55000-132 ........................31<br />
Series 65 CS Heat Detector flashing LED ...........55000-136 ........................31<br />
Series 65 CS Heat Detector flashing LED<br />
and magnetic test switch ..........................................55000-135 ........................31<br />
Series 65 CS Heat Detector Standard ...................55000-137 ........................31<br />
Series 65 Integrating Ionisation Smoke<br />
Detector ............................................................................55000-220 ........................30<br />
Series 65 Integrating Ionisation Smoke<br />
Detector flashing LED ..................................................55000-219 ........................30<br />
Series 65 Integrating Ionisation Smoke Detector<br />
flashing LED and magnetic test switch .................55000-218 ........................30<br />
Series 65 Ionisation Smoke Detector<br />
flashing LED .....................................................................55000-216 ........................30<br />
Series 65 Ionisation Smoke Detector<br />
flashing LED and magnetic test switch ................55000-215 ........................30<br />
Series 65 Ionisation Smoke Detector<br />
Standard ...........................................................................55000-217 ........................30<br />
Series 65 Optical Smoke Detector<br />
flashing LED ...................................................................55000-316 ........................30<br />
Series 65 Optical Smoke Detector<br />
flashing LED and magnetic test switch ................55000-315 ........................30<br />
Series 65 Optical Smoke Detector Standard ......55000-317 ........................30<br />
Series 65 Sounder Base ..............................................45681-512 ........................57<br />
Series 65 Standard Relay Base ...............................45681-245 ........................32<br />
Sounder Beacon Bases 64<br />
AlarmSense Red Cap ...................................................45681-295 ........................65<br />
AlarmSense Sounder Beacon Base ......................45681-509 ........................65<br />
AlarmSense Sounder Beacon Base LR .................45681-340 ........................65<br />
AlarmSense White Cap ...............................................45681-294 ........................65<br />
Discovery Sounder Beacon Base ............................45681-393 ........................65<br />
Red Cap .............................................................................45681-293 ........................65<br />
Sounder Beacon Base ..............................................45681-331 ........................65<br />
Sounder Beacon Base Slow Whoop<br />
with Isolator ....................................................................45681-332 ........................65<br />
Sounder Beacon Base with Australian Tone ......45681-336 ........................65<br />
Sounder Beacon Base with Isolator .......................45681-330 ........................65<br />
Sounder Beacon Base with Isolator DIN-Tone ....45681-334 ........................65<br />
Sounder Beacon Base with NZ Tone ....................45681-338 ........................65<br />
White Cap .........................................................................45681-292 ........................65<br />
Sounder Beacons 62<br />
Intelligent Open-Area Sounder Beacon<br />
Clear Lens (Sonos) ........................................................55000-006 ........................63<br />
Intelligent Open-Area Sounder Beacon<br />
Red Lens (Sonos) ..........................................................55000-005 ........................63<br />
Multi-Tone Open Area Sounder Beacon Red.....55000-291 ........................63<br />
Multi-Tone Open Area Sounder Beacon Red<br />
with Isolator ....................................................................55000-293 ........................63<br />
Multi-Tone Open Area Sounder Beacon White ..55000-292 ........................63<br />
Multi-Tone Open Area Sounder Beacon White<br />
with Isolator ....................................................................55000-294 ........................63<br />
Weatherproof Multi-Tone Open Area<br />
Sounder Beacon Red ...................................................55000-296 ........................63<br />
Weatherproof Multi-Tone Open Area<br />
Sounder Beacon Red with Isolator .........................55000-298 ........................63<br />
Weatherproof Multi-Tone Open Area<br />
Sounder Beacon White ...............................................55000-297 ........................63<br />
Weatherproof Multi-Tone Open Area<br />
Sounder Beacon White with Isolator ....................55000-299 ........................63<br />
XPander Amber Sounder Beacon and<br />
White Sounder Base ....................................................XPA-CB-14004-APO ......63<br />
XPander Clear Sounder Beacon and<br />
White Sounder Base ....................................................XPA-CB-14005-APO ......63<br />
XPander Red Sounder Beacon and<br />
Red Sounder Base ........................................................XPA-CB-14003-APO ......63<br />
Sounders 53<br />
Intelligent 100dB(A) Open-Area Sounder Red..55000-278 ........................54<br />
Intelligent 100dB(A) Open-Area Sounder<br />
Slow Whoop Red ..........................................................55000-276 ........................54<br />
Intelligent 100dB(A) Open-Area Sounder<br />
Slow Whoop White ......................................................55000-277 ........................54<br />
Intelligent 100dB(A) Open-Area Sounder<br />
White..................................................................................55000-279 ........................54<br />
Intelligent 100dB(A) Open-Area<br />
Weatherproof Sounder Red ......................................55000-274 ........................54<br />
Intelligent 100dB(A) Open-Area<br />
Weatherproof Sounder White ..................................55000-275 ........................54<br />
Intelligent Open-Area Sounder Red (Sonos)......55000-001 ........................54<br />
Intelligent Open-Area Sounder White (Sonos) ...55000-002 ........................54<br />
XPander Sounder and Sounder Base Red ...........XPA-CB-14001-APO ......54<br />
XPander Sounder and Sounder Base White .......XPA-CB-14002-APO ......54<br />
Specialist 44<br />
Base Mounted Flame Detector Bracket...............29600-458 ........................47<br />
Conventional Duct Smoke Detector ......................53546-021 ........................51<br />
<strong>Fire</strong>beam Adaptor Plate .............................................29600-353 ........................49<br />
<strong>Fire</strong>beam Beam Detector 5-40m ...........................29600-350 ........................49<br />
<strong>Fire</strong>beam Extension Kit 40-80m .............................29600-351 ........................49<br />
<strong>Fire</strong>beam Extension Kit 80-100m ...........................29600-352 ........................49<br />
Flame Detector Bracket ..............................................29600-203 ........................46<br />
Flame Detector Weathershield................................29600-206 ........................46<br />
Intelligent Base Mounted UV IR² Flame<br />
Detector ...........................................................................55000-023 ........................47<br />
Intelligent Base Mounted UV Flame Detector ...55000-022 ........................47<br />
Intelligent Base Mounted IR3 Flame<br />
Detector ............................................................................55000-024 ........................47
Intelligent Duct Detector ............................................53546-022 ........................51<br />
Intelligent Flameproof IR² Flame Detector ..........55000-295 ........................46<br />
Intelligent Flameproof IR³ Flame Detector ..........55000-021 ........................46<br />
Intelligent IR² Flame Detector ..................................55000-280 ........................46<br />
Intelligent IR 3 Flame Detector ..................................55000-020 ........................46<br />
Orbis Duct Detector ......................................................53546-023 ........................51<br />
Reflective Beam Detector (50-100m) .................55000-273 ........................49<br />
Reflective Beam Detector (5-50m).......................55000-268 ........................49<br />
Reflective Beam Detector Backbox .......................29600-241 ........................49<br />
Standard Interfaces 69<br />
Input/Output Unit ..........................................................55000-847 ........................70<br />
Mains Switching Input/Output Unit .......................55000-875 ........................71<br />
Output Unit ......................................................................55000-849 ........................70<br />
Sounder Control Unit ....................................................55000-852 ........................70<br />
Switch Monitor Plus .....................................................55000-841 ........................71<br />
Switch Monitor ...............................................................55000-843 ........................71<br />
Three Channel Input/Output Unit ...........................55000-588 ........................70<br />
Three Channel Input/Output Unit PCB only ........43781-588 ........................70<br />
Zone Monitor Unit .........................................................55000-845 ........................71<br />
Test Equipment and Maintenance 116<br />
1.5mm Hexagonal Driver (locks detectors<br />
to bases) .........................................................................29600-095 .................... 118<br />
Aerosol Test Gas ..........................................................29600-225 .................... 118<br />
Battery Batons ..............................................................29600-183 .................... 118<br />
Battery Charger (No Mains Lead)...........................29600-214 .................... 118<br />
Conventional Test Set .................................................53832-020 ..................... 117<br />
Cordless Heat Detector Tester ................................29600-213 .................... 118<br />
Cordless Heat Tester Kit ............................................29600-212 .................... 118<br />
CO Test Gas .....................................................................29600-235 ..................... 114<br />
Detector Extract Tool ..................................................29600-102 .................... 118<br />
Discovery Programmer ..............................................53832-030 ..................... 117<br />
Extension Pole, 1.13m ...............................................29600-103 .................... 118<br />
Flame Sensor Test Unit and Case ...........................29600-226 ..................... 117<br />
Heat Detector Test Pole (110V) .............................29600-110 .................... 118<br />
Heat Detector Test Pole (240V) ..............................29600-101 .................... 118<br />
Printer for XP95 Test Set ............................................55000-872 ..................... 117<br />
Smoke Dispenser Head ............................................29600-100 .................... 118<br />
Telescopic Pole, 1.26m to 4.5m ............................29600-104 .................... 118<br />
Detector Duster .............................................................29600-449 ..................... 118<br />
Smoke/Heat Unit ..........................................................29600-459 ..................... 118<br />
Smoke/Heat Kit .............................................................29600-460 ..................... 118<br />
Smoke/Heat/CO Unit ..................................................29600-461 ..................... 118<br />
Smoke/Heat/CO Kit .....................................................29600-462 ..................... 118<br />
6-Pack Replacement Smoke Capsule ...................29600-463 ..................... 118<br />
3-Pack Replacement Smoke Capsule ...................29600-464 ..................... 118<br />
6-Pack Replacement CO Capsule ...........................29600-465 ..................... 118<br />
3-Pack Replacement CO Capsule ...........................29600-466 ..................... 118<br />
UK Mains Lead ..............................................................29600-215 .................... 118<br />
XP95 Test Set .................................................................55000-870 ..................... 117<br />
XPERT Card Insertion Tool .........................................45681-235 .................... 118<br />
Index: Product 137<br />
XP95 16<br />
Intelligent Deep Base ..................................................45681-209 ........................19<br />
Intelligent Mounting Base ..........................................45681-210 ........................18<br />
Isolator ...............................................................................55000-720 ........................18<br />
Isolator Base ....................................................................45681-211 ........................18<br />
Low Power Relay Base ...............................................45681-242 ........................19<br />
New Isolating Base ......................................................45681-284 ........................18<br />
MiniDisc Remote Indicator.........................................53832-070 ........................19<br />
Polycarbonate Deckhead Mounting Box .............29600-196 ........................19<br />
Printer for XP95 Test Set ............................................55000-872 ..................... 117<br />
Waterproof Base Cover ..............................................45681-519 ........................19<br />
XP95 Base Cover .........................................................45681-380 ........................83<br />
XP95 Heat Detector High Temperature ...............55000-401 ........................17<br />
XP95 Heat Detector Standard ..................................55000-400 ........................17<br />
XP95 Heater Base .........................................................45681-219 ........................19<br />
XP95 Ionisation Smoke Detector ............................55000-500 ........................17<br />
XP95 Manual Call Point - Red (Surface) ...............55100-905 ........................79<br />
XP95 Manual Call Point with Isolator -<br />
Red (Surface) ..................................................................55100-908 ........................79<br />
XP95 Multisensor Detector .......................................55000-885 ........................17<br />
XP95 Optical Smoke Detector .................................55000-600 ........................17<br />
XP95 Test Set .................................................................55000-870 ..................... 117<br />
XP95A 103<br />
XP95A Isolating Base ...................................................45681-321USA ............. 105<br />
XP95A 4” Low Power Relay Base ..........................45681-242USA ............. 106<br />
XP95A 4” Mounting Base ..........................................45681-210USA ............. 105<br />
XP95A 6” Mounting Base ..........................................45681-225USA ............. 105<br />
XP95A Dual Priority Switch Monitor Module .....55000-790 ..................... 107<br />
XP95A E-Z Fit Base .......................................................45681-250 ..................... 104<br />
XP95A Heat Detector ..................................................55000-450 ..................... 104<br />
XP95A Ionization Smoke Detector .........................55000-550 ..................... 104<br />
XP95A Isolator ...............................................................55000-750 ..................... 105<br />
XP95A Isolator Base .....................................................45681-211USA ............. 105<br />
XP95A Loop Powered Beam Detector ................55000-266 .....................104<br />
XP95A Mini Priority Switch Monitor Module ......55000-830 ..................... 106<br />
XP95A Mini Switch Monitor Module .....................55000-831 ..................... 106<br />
XP95A Multisensor Detector ....................................55000-886 ..................... 104<br />
XP95A Photo-Electric Smoke Detector ................55000-650 ..................... 104<br />
XP95A Priority Switch Monitor Module ................55000-806 ..................... 107<br />
XP95A Relay Output Module ...................................55000-863 ..................... 107<br />
XP95A Sounder Control Module .............................55000-825 ..................... 107<br />
XP95A Switch Monitor Input/Output Module ...55000-820 ..................... 107<br />
XP95A Switch Monitor Module ...............................55000-805 ..................... 106<br />
Mini Monitor Module ...................................................55000-765 ..................... 106<br />
XP95 IS 95<br />
IS Galvanic Barrier .........................................................29600-098 ........................97<br />
XP95 IS Heat Detector.................................................55000-440 ........................96<br />
XP95 IS Ionisation Smoke Detector .......................55000-540 ........................96<br />
XP95 IS Manual Call Point MEDC Break<br />
Glass - Black/Yellow Stripes .....................................55000-966 ........................97
138<br />
Index: Product<br />
XP95 IS Manual Call Point MEDC Break<br />
Glass - Blue ......................................................................55000-964 ........................97<br />
XP95 IS Manual Call Point MEDC Break<br />
Glass - Red .......................................................................55000-960 ........................97<br />
XP95 IS Manual Call Point MEDC Break<br />
Glass - Yellow .................................................................55000-962 ........................97<br />
XP95 IS Manual Call Point MEDC Break<br />
Glass with flap - Black/Yellow Stripes ..................55000-967 ........................97<br />
XP95 IS Manual Call Point MEDC Break<br />
Glass with flap - Blue ...................................................55000-965 ........................97<br />
XP95 IS Manual Call Point MEDC Break<br />
Glass with flap - Red ....................................................55000-961 ........................97<br />
XP95 IS Manual Call Point MEDC Break<br />
Glass with flap - Yellow ..............................................55000-963 ........................97<br />
XP95 IS Manual Call Point MEDC Push<br />
Button - Black/Yellow Stripes ..................................55000-973 ........................97<br />
XP95 IS Manual Call Point MEDC Push<br />
Button - Blue ...................................................................55000-972 ........................97<br />
XP95 IS Manual Call Point MEDC Push<br />
Button - Red ....................................................................55000-970 ........................97<br />
XP95 IS Manual Call Point MEDC Push<br />
Button - Yellow ..............................................................55000-971 ........................97<br />
XP95 IS Manual Call Point With Flap -<br />
Blue/White.......................................................................55000-945 ........................97<br />
XP95 IS Manual Call Point Without Flap -<br />
Blue/White.......................................................................55100-944 ........................97<br />
XP95 IS Manual Call Point Without Flap - Red ...55100-940 ........................97<br />
XP95 IS Manual Call Point Without Flap - Yellow 55100-942 ........................97<br />
XP95 IS Mounting Base ..............................................45681-215 ........................97<br />
XP95 IS Optical Smoke Detector .............................55000-640 ........................97<br />
XP95 Protocol Translator (Dual) ..............................55000-856 ........................97<br />
XP95 Protocol Translator (Single) ...........................55000-855 ........................97<br />
XPander 41<br />
XPander A1R Heat Detector and Mounting Base ..XPA-CB-11170-APO ......42<br />
XPander Amber Sounder Beacon and<br />
White Sounder Base ....................................................XPA-CB-14004-APO ......63<br />
XPander Clear Sounder Beacon and<br />
White Sounder Base ....................................................XPA-CB-14005-APO ......63<br />
XPander CS Heat Detector and Mounting Base XPA-CB-11171-APO ......42<br />
XPander Interface Unit ................................................XPA-IN-14007-APO .......43<br />
XPander Manual Call Point ........................................XPA-MC-14006-APO .....80<br />
XPander Multisensor Detector and Mounting<br />
Base ....................................................................................XPA-CB-13032-APO ......42<br />
XPander Optical Smoke Detector and<br />
Mounting Base ...............................................................XPA-CB-12034-APO ......42<br />
XPander Red Sounder Beacon and<br />
Red Sounder Base ........................................................XPA-CB-14003-APO ......63<br />
XPander Sounder and Sounder Base Red ...........XPA-CB-14001-APO ......54<br />
XPander Sounder and Sounder Base White .......XPA-CB-14002-APO ......54<br />
XPander Survey Tool ...................................................XPA-TE-14010-APO .......43<br />
XPERT Cards 22<br />
Blank XPERT Card ..........................................................38531-771 ........................23<br />
Pre-Addressed XPERT Cards .....................................45682-127 ........................23
Apollo Overseas Offices<br />
Apollo America<br />
821 Ulrich Avenue<br />
Louisville<br />
Kentucky<br />
40219<br />
USA<br />
Tel: +1 502 964 6565<br />
Fax: +1 502 964 6229<br />
Email: infoUSA@apollo-fire.com<br />
Web: www.apollo-fire.com<br />
Apollo Germany<br />
Apollo GmbH<br />
Am Anger 31<br />
D-33332 Gütersloh<br />
Germany<br />
Tel: +49 5241 33060<br />
Fax: +49 5241 330629<br />
Email: verkauf@apollo-feuer.de<br />
Web: www.apollo-feuer.de<br />
Apollo Spain<br />
Apollo <strong>Fire</strong> Detectors S.A.<br />
Calle Rio Tietar 12<br />
Nave 6<br />
Pol Ind El Nogal<br />
28110 Algete<br />
Madrid<br />
Spain<br />
Tel: +34 9162 89209<br />
Fax: +34 9162 90168<br />
Email: información@apollo-fire.com<br />
Web: www.apollo-fire.es<br />
Apollo Ireland<br />
Apollo Ireland<br />
8 Willbrook Road<br />
Rathfarnham<br />
Dublin 14<br />
Republic of Ireland<br />
Tel: +353 1 493 3896<br />
Email: info-ireland@apollo-fire.co.uk<br />
Web: www.apollo-fire.ie<br />
Apollo China<br />
Apollo China<br />
24D Huamin Empire Plaza<br />
726 Yan An Road (W)<br />
Shanghai<br />
200050<br />
The People’s Republic of China<br />
Tel: +86 21 5237 0922<br />
Fax: +86 21 5237 0920<br />
Email: info-china@apollo-fire.com<br />
Web: www.apollo-fire.com.cn<br />
© Apollo <strong>Fire</strong> Detectors Ltd 2007-2009<br />
PP2327/2009/Issue 4