www.apollo-fire.co.uk<br />

PRODUCT CATALOGUE 2009<br />

<strong>Fire</strong> <strong>detection</strong><br />

<strong>equipment</strong>


By Appointment to<br />

Her Majesty The Queen<br />

Manufacturers of <strong>Fire</strong> Detection<br />

& Alarm Products<br />

Apollo <strong>Fire</strong> Detectors Limited<br />

Hampshire<br />

Why Choose Apollo?<br />

• Largest independent smoke detector<br />

manufacturer in the world<br />

• Certified to all key international approvals<br />

• The best people work for Apollo<br />

• Trustworthy, integrity & supportive<br />

• Localised customer service worldwide<br />

• Ex stock delivery<br />

• 100% reliability, 100% tested<br />

• Open, digital protocol<br />

• Forwards and backwards product compatibility<br />

• World<br />

Class <strong>Fire</strong> Solutions<br />

Apollo - The Partner of Choice<br />

Apollo <strong>Fire</strong> Detectors Ltd. has specialised in the design and<br />

manufacture of high quality fire <strong>detection</strong> products since<br />

1980. In that time, the company has broadened its capability<br />

from a straightforward focus on conventional fire detectors<br />

to include the manufacture of sophisticated analogue<br />

addressable detectors and interfaces for monitoring and<br />

controlling <strong>equipment</strong> in fire protection systems.<br />

Apollo applies the most modern production techniques and has<br />

invested in sophisticated manufacturing <strong>equipment</strong> to ensure<br />

consistent high quality products and fast response to customer<br />

requirements. Through planned expansion, Apollo has reached a<br />

leading position in the market for professional fire detectors detectors and<br />

exports over over half of its its production to countries countries around the world.<br />

In 2007, Apollo Apollo unveiled unveiled a new brand brand identity, further cementing cementing<br />

its position as a world class fire solutions solutions provider.<br />

Based in Havant, Hampshire, Apollo operates from one site. All<br />

departments - Research and Development, Sales and Marketing,<br />

Manufacturing and Finance are located here.<br />

Apollo is a Halma company. Halma is a holding company for over 40<br />

subsidiaries worldwide, all engaged in specialist engineering activities.<br />

Information in this catalogue is given in good faith, but Apollo <strong>Fire</strong> Detectors cannot be held responsible for any omissions or errors. The<br />

company reserves the right to change specifications of products at any time without prior notice.


4<br />

6<br />

8<br />

24<br />

34<br />

40<br />

44<br />

52<br />

68<br />

How do Detectors Work?<br />

New Products<br />

Intelligent <strong>Fire</strong> Detection<br />

Discovery, XP95<br />

Conventional <strong>Fire</strong> Detection<br />

Orbis, Series 65<br />

Two-wire technology<br />

AlarmSense<br />

Wireless technology<br />

XPander<br />

Specialist Detectors<br />

Flame, Beam & Duct Detectors<br />

Audio Visual Signalling<br />

Sounders, Beacons, Sounder Beacons,<br />

Sounder Beacon Bases<br />

Interfaces<br />

Isolated, Non-Isolated, Mini, DIN-Rail<br />

78<br />

82<br />

86<br />

94<br />

102<br />

116<br />

120<br />

122<br />

129<br />

Manual Call Points<br />

Mounting Accessories<br />

Marine<br />

Discovery, Orbis<br />

Intrinsically Safe<br />

XP95, Orbis<br />

UL<br />

XP95A, Series 65A, Discovery UL<br />

Test Equipment and Maintenance<br />

Additional Services<br />

Loop Calculator, Training<br />

Approvals<br />

Index<br />

Contents


4 How do Detectors Work?<br />

How do<br />

Detectors<br />

Work?<br />

Ionisation smoke detector<br />

The sensing part of the detector consists of two<br />

chambers - an open, outer chamber and a semi-sealed<br />

reference chamber within. Mounted in the reference<br />

chamber is a low activity radioactive foil of Americium<br />

241 which enables current to flow between the inner and<br />

outer chambers when the detector is powered up. As<br />

smoke enters the detector, particles become attached to<br />

the ions, causing a reduction in current flow in the outer<br />

chamber and hence an increase in voltage measured at<br />

the junction between the two chambers. The voltage<br />

increase is monitored by the electronic circuitry which<br />

triggers the detector into the alarm state at a preset<br />

threshold. An externally visible red LED lights up when<br />

the detector changes to alarm state.<br />

Ionisation smoke detectors are good general-purpose<br />

detectors which respond well to fast-burning<br />

(flaming) fires and are widely used for property<br />

protection.<br />

Integrating ionisation smoke detector<br />

This type of detector works on the same principles as<br />

the ionisation smoke detector, but has modified signal<br />

processing circuitry which allows an alarm threshold to be<br />

present for up to 20 seconds without initiating an alarm.<br />

This type of detector is suitable for use in areas where<br />

transient high levels of smoke may be expected.<br />

Integrating effect in analogue addressable systems<br />

In XP95 systems, the integrating effect can be mimicked<br />

in both ionisation and optical smoke detectors by<br />

adjusting the control <strong>equipment</strong> software to cause an<br />

appropriate delay. Discovery smoke detectors should be<br />

set to Mode Two or Mode Four to achieve this effect.<br />

Optical (photo-electric) smoke detector<br />

Optical smoke detectors incorporate a pulsing infra-red<br />

LED located in a chamber within the housing of the<br />

detector. The chamber is designed to exclude light from<br />

any external source. At an angle to the LED is a photodiode<br />

which normally does not register the column of<br />

light emitted by the LED. In the event of smoke from a<br />

fire entering the chamber, the light pulse from the LED<br />

will be scattered and hence registered by the photodiode.<br />

If the photo-diode ‘sees’ smoke on the two<br />

following pulses, the detector changes into alarm state<br />

and the indicator LED lights up. The detector housing<br />

is identical to that of the ionisatio n detector but has<br />

an indicator LED which is clear in quiescent state but<br />

produces red light in alarm.<br />

Optical smoke detectors respond particularly well to<br />

slow-burning (smouldering) fires. They are widely<br />

used for life protection.


Heat detector<br />

Most conventional heat detectors operate by using a<br />

matched pair of thermistors to sense heat. One thermistor<br />

is exposed to the ambient temperature, the other is<br />

sealed. In normal conditions the two thermistors register<br />

similar temperatures, but, on the development of a fire,<br />

the temperature recorded by the exposed thermistor<br />

will increase rapidly, resulting in an imbalance of the<br />

thermistors, causing the detector to change into alarm<br />

state. Rate-of-rise detectors are designed to detect a fire<br />

as the temperature increases, but they also have a fixed<br />

upper limit at which the detector will go into alarm if the<br />

rate of temperature increase has been too slow to trigger<br />

the detector earlier.<br />

The Series 65 and AlarmSense CS (static response) heat<br />

detectors have only one thermistor. They change to the<br />

alarm state at a preset temperature.<br />

Externally, the heat detectors are distinguishable from<br />

the smoke detectors by having wide openings to the<br />

surrounding atmosphere to allow good movement of air<br />

around the external thermistor.<br />

A heat detector may be more appropriate than a<br />

smoke detector where the environment is dirty<br />

or smoky under normal conditions. It must be<br />

recognised, however, that any heat detector will<br />

respond only when a fire is well established and<br />

generating a high heat output.<br />

Multisensor detector<br />

A multisensor detector is basically an optical smoke<br />

detector - so it will respond well to smouldering fires. The<br />

addition of a heat sensing element allows the multisensor<br />

to give a response to fast burning (flaming) fires which is<br />

comparable to that of an ionisation detector.<br />

Multisensor detectors are general purpose detectors<br />

which respond well to a wide range of fires.<br />

How do Detectors Work?<br />

Carbon Monoxide (CO) detector<br />

Carbon Monoxide (CO) is a poisonous gas produced by<br />

combustion and a CO fire detector is used to indicate the<br />

outbreak of a fire by sensing the level of CO in the air.<br />

The detector has an electrochemical cell which senses CO,<br />

but not smoke or other combustion products. The cells<br />

do not require much power, so the detector can be made<br />

electrically compatible with ordinary smoke and heat<br />

detectors. Apollo manufacturers a CO detector as part of<br />

the Discovery range.<br />

CO detectors are particularly good at detecting deepseated,<br />

smouldering fires.<br />

Beam detector<br />

A beam detector is made up of three main parts: the<br />

transmitter, which projects a beam of infra-red light;<br />

the receiver which registers the light and produces an<br />

electrical signal; and the interface, which processes the<br />

signal and generates alarm or fault signals. When a fire<br />

develops, smoke particles obstruct the beam of light and,<br />

once a pre-set threshold has been exceeded, the detector<br />

will go into alarm.<br />

Beam detectors are designed to protect large<br />

open spaces such as atria, museums, churches and<br />

warehouses.<br />

Flame detector<br />

A flame detector is designed to detect either ultraviolet<br />

(UV) or infra-red (IR) radiation emitted by a fire. The XP95<br />

Dual IR flame detector is sensitive to low-frequency,<br />

flickering infra-red radiation. This means that the detector<br />

can operate even if the lens is contaminated by a layer of<br />

oil, dust, water vapour or ice.<br />

Flame detectors are effective in protecting areas<br />

where flaming fires may be expected.<br />

5


6 New Products<br />

New<br />

Products<br />

Apollo prides itself on being a leader in product<br />

innovation. Providing fire solutions that meet the<br />

demands of our customers is the main pillar of<br />

Apollo’s product development programme. We<br />

are constantly working with our customers to<br />

develop new products to meet their needs.<br />

A further commitment to Apollo’s customer focus<br />

has seen the Marketing team be strengthened<br />

by the introduction of three new product<br />

management roles. These dedicated personnel<br />

will be responsible for the future direction of the<br />

portfolio as well as the internal management of<br />

the ranges.<br />

A prime responsibility of the new roles is<br />

continuation of customer focused product<br />

development within Apollo and continuing to be<br />

the Partner of Choice.<br />

If you have any comments or suggestions on<br />

any new or existing products, feel free to email<br />

ideas@apollo-fire.co.uk


New products for 2009<br />

Discovery Upgrade<br />

The Discovery range has been subjected to a<br />

thorough revision of the electronics and this<br />

has resulted in significant improvement to the<br />

Multisensor detector capabilities. It is possible<br />

to read out virtually instantly the analogue<br />

values for smoke and heat separately.<br />

DIN-Rail Mains Input/Output Unit<br />

The DIN-Rail Mains Input/Output Unit provides<br />

a voltage-free, single pole change-over relay<br />

output and a monitored switch input. The<br />

unit supervises one or more normally-open<br />

switches connected to a single pair of cables.<br />

DIN-Rail Sounder Controller (5 Amperes)<br />

The DIN-Rail Sounder Controller (5 Amperes)<br />

is used to control the operation of a zone of<br />

externally powered sounders and report their<br />

status to the control panel.<br />

Deckhead Mounting Box<br />

The Deckhead Mounting Box gives extra<br />

protection to devices to be fitted in areas<br />

where there is the possibility of moisture or<br />

condensation ingressing through the rear of<br />

the of the base. This new version is suitable<br />

for a wider range of detector bases as well<br />

as Apollo’s AV bases.<br />

2009 – Under<br />

development<br />

New Products<br />

There are a number of new products due for<br />

launch during the course of 2009. They are at<br />

the early stages of development. When ready<br />

for launch the website, eMonitor and Monitor<br />

newsletters will announce this, so keep an eye<br />

out! Products currently under development, in<br />

no particular order include:<br />

XPander Input/Output Unit<br />

Locally Powered Zone Monitor<br />

DIN-Rail Zone Monitor for IS Heads<br />

110dB(A) Open-Area Sounder Beacon<br />

Marine 110dB(A) Open-Area Sounder Beacon<br />

Discovery CO/Heat Detector<br />

Sounder Controller 8 Amperes (Marine)<br />

Conventional Flush Mounted Smoke Detector<br />

Marine DIN-Rail Mains Input/Output Unit<br />

Marine Base Mounted Flame Detectors<br />

Discovery Open-Area Sounder Beacon<br />

UL approved Open-Area Sounder<br />

UL approved Releasing Control Module<br />

UL approved Mini Monitor Module<br />

7


108 Intelligent <strong>Fire</strong> Detection<br />

Intelligent<br />

<strong>Fire</strong><br />

Detection<br />

In an Intelligent system all devices have unique ‘addresses’ and are<br />

connected in loops to the control panel. Intelligent systems give advanced<br />

warning of a developing hazard and can pinpoint the individual device<br />

raising alarm. There are two types of intelligent system – those with<br />

‘distributed intelligence’ and those with ‘centralised intelligence’.<br />

In systems with distributed intelligence the detectors incorporate<br />

processors which can determine whether alarm levels of smoke or heat<br />

exist and can initiate action accordingly.<br />

Detectors in systems with centralised intelligence monitor the air around<br />

them for smoke or heat and transmit the data to the control panel on<br />

interrogation. The processor in the panel compares the values with stored<br />

values and determines whether a pre-alarm or alarm should be signalled.<br />

The advantages of distributed intelligence are local adaptation to<br />

environment and reduction of traffic on the supply and data wires. The<br />

advantage of centralised intelligence is the ability to upgrade a system very<br />

quickly and easily by upgrading the control panel.


Discovery is a range of high-specification,<br />

intelligent fire detectors developed to<br />

meet the requirements of sophisticated<br />

systems while providing engineers with<br />

an additional dimension in fire protection<br />

capability. Discovery has a ‘distributed<br />

intelligence system’ where decisions are<br />

made in the detector head as well as<br />

at the control panel. Drift compensation<br />

is also incorporated into the detector,<br />

allowing it to adapt to dirty or dusty<br />

environments, which reduces false alarms.<br />

Each detector in the Discovery range can operate in one<br />

of five response modes, which can be selected from the<br />

control panel or hand held programmer. The response<br />

characteristics have been carefully set so that the detectors<br />

comply with the requirements of the relevant part of<br />

EN54 in all response modes. Mode One will give a higher<br />

sensitivity to fire than Mode Five.<br />

Discovery gives you total reassurance in installations where<br />

adaptability to changing conditions and protection against<br />

unwanted alarms is paramount.<br />

Key features of Discovery include:<br />

• Rejection of transient signals<br />

• Flashing LED option<br />

• Five response modes for ease of optimisation to<br />

changing environments<br />

• Drift compensation to ensure constant sensitivity<br />

• Four bytes of non-volatile memory for user data<br />

• Alarm flag for fast alarm reporting<br />

• Conventional alarm facility during control panel<br />

processor fault<br />

• 360° visibility in alarm<br />

• Compatible with XP95 systems<br />

• Insect Resistant<br />

NEW FOR 2009!<br />

Intelligent <strong>Fire</strong> Detection<br />

DISCOVERY<br />

Discovery<br />

intelligent fire<br />

<strong>detection</strong><br />

The Discovery range has been subjected to a<br />

thorough revision of the electronics and this has<br />

resulted in significant improvement to the Multisensor<br />

detector capabilities. It is possible to read out virtually<br />

instantly the analogue values for smoke and heat<br />

separately.<br />

This enables panel manufacturers to develop features<br />

which will provide more effective management<br />

of false alarms. An example of this would be an<br />

increased smoke value which might normally lead to<br />

a pre-alarm or even an alarm. If the heat value is read<br />

out separately and it shows little or no rise it can be<br />

concluded that it is not smoke from a fire but steam<br />

which is causing the high smoke analogue value.<br />

9


10 Intelligent <strong>Fire</strong> Detection<br />

DISCOVERY<br />

Discovery Ionisation Smoke Detector<br />

The Discovery Ionisation Smoke Detector uses<br />

a low activity radioactive foil to detect fires by<br />

irradiating the air in the smoke chambers and<br />

causing a current flow. If smoke enters the<br />

chamber, the current flow is reduced leading<br />

to an alarm.<br />

Discovery Ionisation Smoke Detector 58000-500<br />

Discovery Optical Smoke Detector<br />

The Discovery Optical Smoke Detector works<br />

using the light scatter principle and is ideal for<br />

applications where slow-burning or smouldering<br />

fires are likely.<br />

Discovery Optical Smoke Detector 58000-600<br />

Discovery Heat Detector<br />

The Discovery Heat Detector, distinguishable<br />

by the low airflow resistant case, uses a single<br />

thermistor to sense the air temperature around<br />

the detector.<br />

Discovery Heat Detector 58000-400<br />

Discovery Multisensor Detector<br />

The Discovery Multisensor Detector comprises<br />

optical smoke and thermistor temperature sensors<br />

whose outputs are combined to give the final<br />

analogue value. As a result, the multisensor is<br />

useful over a wide range of applications and is<br />

highly immune to false alarms.<br />

Discovery Multisensor Detector 58000-700<br />

Discovery Carbon Monoxide Detector<br />

The Discovery Carbon Monoxide (CO) Detector is<br />

good at detecting deep-seated fires. Please note<br />

that CO detectors do not detect smoke particles<br />

or heat and are not universal replacements for<br />

smoke detectors.<br />

Discovery Carbon Monoxide Detector 58000-300<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

• Responds well to fast-burning, flaming fires<br />

• Designed to operate in a variety of<br />

environments<br />

• Remote test feature<br />

• Responds well to slow-burning, smouldering<br />

fires<br />

• Well suited for bedrooms and escape routes<br />

• Unaffected by wind or atmospheric pressure<br />

• Remote test feature<br />

• Ideal in environments that are dirty or smoky<br />

under normal conditions<br />

• Well suited for warehouses, loading bays and<br />

car parks<br />

• Unaffected by wind or atmospheric pressure<br />

• Remote test feature<br />

• Ideal for a wide range of applications<br />

• Enhanced false alarm management<br />

• Well suited for environments such as hotel<br />

bedrooms<br />

• Unaffected by wind or atmospheric pressure<br />

• Well suited for sensitive environments<br />

• Heat only, optical only options<br />

• Remote test feature<br />

• Enhanced <strong>detection</strong> capability<br />

• Early response to hot fires<br />

• Ideal for smouldering fires<br />

• Less susceptible to false alarms caused by<br />

steam than smoke alarms<br />

• Five response modes<br />

• Remote test feature


Intelligent Mounting Base<br />

All detectors in the Discovery range fit the<br />

Intelligent Mounting Base. The Mounting Base<br />

is a low insertion force base with stainless steel<br />

contacts for the detector terminals. XPERT cards<br />

are supplied with all bases.<br />

Intelligent Mounting Base 45681-210<br />

Intelligent Deep Base<br />

The Intelligent Deep Base is a mounting base for<br />

Discovery products which has an increased depth<br />

which allows for cables to be inserted into the<br />

side of the product.<br />

Intelligent Deep Base 45681-209<br />

Isolating Base<br />

The new style Isolating Base senses and detects<br />

short-circuit faults on Discovery loops and spurs.<br />

Isolating Base 45681-284<br />

Product will replace 45681-321 during 2009<br />

Isolator<br />

The Isolator is placed at intervals on the loop and<br />

ensures that, in the case of a short-circuit, only<br />

the section between the isolators will be affected.<br />

When the short-circuit is removed, the isolators<br />

automatically restore power and data to the<br />

isolated section.<br />

Isolator 55000-720<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

Intelligent <strong>Fire</strong> Detection<br />

DISCOVERY<br />

• XPERT addressing<br />

• One way fit<br />

• Locking feature to prevent unauthorised<br />

removal<br />

• Enables surface wiring<br />

• The equivalent of up to 20 smoke detectors<br />

may be installed between isolating bases<br />

• High brightness LED<br />

• Compatible with Discovery CO detector<br />

• Detects wiring short circuits using patented<br />

technology<br />

• Minimises disruption from short-circuits<br />

• Automatic de-isolation on short-circuit removal<br />

• The equivalent of up to 20 smoke detectors<br />

may be installed between isolators<br />

11


12 Intelligent <strong>Fire</strong> Detection<br />

DISCOVERY<br />

Isolator Base<br />

The Isolator Base is unique and designed to only<br />

accept the Isolator 55000-720.<br />

Isolator Base 45681-211<br />

Intelligent Low Power Relay Base<br />

The Low Power Relay Base incorporates a low<br />

power relay to control field <strong>equipment</strong> such as<br />

automatic door closers.<br />

Intelligent Low Power Relay Base 45681-242<br />

Intelligent Heater Base<br />

The Intelligent Heater Base is designed to be used<br />

in cold climates where environmental conditions<br />

could result in either icing or condensation<br />

affecting the operation of detectors. It is<br />

recommended that the heater base be used in<br />

conjunction with either a Waterproof Base Cover<br />

or Deckhead Mounting Box to minimise moisture<br />

ingress.<br />

Intelligent Heater Base 45681-219<br />

Waterproof Base Cover 45681-519<br />

Deckhead Mounting Box 45681-217<br />

MiniDisc Remote Indicator<br />

The MiniDisc Remote Indicator is a light-weight,<br />

compact LED indicator for use in fire protection<br />

systems.<br />

MiniDisc Remote Indicator 53832-070<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

• Only accepts isolators<br />

• Gives a set of voltage free contacts controlled<br />

by the remote output of a detector<br />

• Draws negligible current<br />

• Capable of switching up to 30V at 1A<br />

• Raises the ambient temperature of a detector<br />

chamber by approximately 10°C<br />

• Limits the risk of potential for lose of<br />

functionality caused to detectors installed in<br />

these conditions.<br />

• Can be used across the entire Apollo range<br />

• Small and discrete<br />

• Anti-tamper screw to protect against<br />

unauthorised removal


Ancillary devices available for the Discovery range:<br />

Intelligent <strong>Fire</strong> Detection<br />

DISCOVERY<br />

Product Name Part Number Page No.<br />

MOUNTING ACCESSORIES 82<br />

Backplate 45681-233 83<br />

Base Cover 45681-380 83<br />

Conduit Box 45681-204 83<br />

Sounder Ceiling Plate 45681-311 83<br />

Module Base 38531-822 83<br />

Deckhead Mounting Box 45681-217 84<br />

Metal Deckhead Mounting Box PG16 29600-131 84<br />

Metal Deckhead Mounting Box M20 29600-139 84<br />

Deckhead Adaptor PG16-M20 27249-005 84<br />

Detector Ceiling Tile Mounting Box 45681-309 84<br />

Sounder Ceiling Tile Mounting Box 45681-310 84<br />

Beacon Enclosure 29600-318 84<br />

DIN-Rail Interface Enclosure (4 units) 29600-239 85<br />

DIN-Rail Interface Enclosure (10 units) 29600-240 85<br />

1.5mm Hexagonal Driver 29600-095 85<br />

MANUAL CALL POINTS 78<br />

Discovery Manual Call Point Red (Surface) 58100-910 79<br />

Discovery Manual Call Point with Isolator Red (Surface) 58100-908 79<br />

Discovery Manual Call Point White 58100-926 79<br />

Discovery Manual Call Point Yellow 58100-927 79<br />

Discovery Manual Call Point Blue 58100-928 79<br />

Discovery Manual Call Point Green 58100-929 79<br />

Transparent Hinged Cover 26729-152 79<br />

Weatherproof Manual Call Point Red 58100-950 80<br />

Weatherproof Manual Call Point Red with Isolator 58100-951 80<br />

STANDARD INTERFACES 69<br />

Input/Output Unit 55000-847 70<br />

Three Channel Input/Output Unit 55000-588 70<br />

Three Channel Input/Output Unit PCB only 43781-588 70<br />

Output Unit 55000-849 70<br />

Sounder Control Unit 55000-852 70<br />

Switch Monitor 55000-843 71<br />

Switch Monitor Plus 55000-841 71<br />

Zone Monitor 55000-845 71<br />

MINI INTERFACES 73<br />

Mini Switch Monitor 55000-760 74<br />

Mini Switch Monitor with fly leads 55000-833 74<br />

Mini Switch Monitor with fly leads (Interrupt) 55000-832 74<br />

DIN-RAIL INTERFACES 75<br />

NEW!! DIN-Rail Sounder Controller (5 Amperes) 55000-182 76<br />

DIN-Rail Input/Output Unit 55000-803 76<br />

DIN-Rail Output Unit 55000-804 76<br />

DIN-Rail Switch Monitor 55000-822 76<br />

DIN-Rail Switch Monitor Plus 55000-821 77<br />

DIN-Rail Zone Monitor with Isolator 55000-812 77<br />

DIN-Rail Dual Isolator 55000-802 77<br />

13


14 Intelligent <strong>Fire</strong> Detection<br />

DISCOVERY<br />

Product Name Part Number Page No.<br />

AUDIO <strong>VIS</strong>UAL SIGNALLING<br />

Discovery Sounder Beacon Base 45681-393 65<br />

Intelligent Open-Area Sounder Red 55000-001 54<br />

Intelligent Open-Area Sounder White 55000-002 54<br />

Intelligent 100dB (A) Open-Area Sounder Red 55000-278 54<br />

Intelligent 100dB (A) Open-Area Sounder White 55000-279 54<br />

Intelligent 100dB (A) Open-Area Sounder Slow Whoop Red 55000-276 54<br />

Intelligent 100dB (A) Open-Area Sounder Slow Whoop White 55000-277 54<br />

Intelligent 100dB (A) Open-Area Weatherproof Sounder Red 55000-274 54<br />

Intelligent 100dB (A) Open-Area Weatherproof Sounder White 55000-275 54<br />

Integrated Base Sounder 45681-278 56<br />

Integrated Base Sounder with Isolator 45681-277 56<br />

Integrated Base Sounder Slow Whoop 45681-291 56<br />

Integrated Base Sounder Slow Whoop with Isolator 45681-290 56<br />

Integrated Base Sounder DIN-Tone with Isolator 45681-300 56<br />

White Cap 45681-292 56<br />

Red Cap 45681-293 56<br />

Intelligent Base Sounder 45681-265 56<br />

Intelligent Base Sounder, for use with Isolating Base 45681-266 56<br />

Intelligent Base Sounder Slow Whoop 45681-267 56<br />

Intelligent Base Sounder Slow Whoop for use with Isolating Base 45681-268 56<br />

White Cap 29600-256 56<br />

Red Cap 29600-257 56<br />

Ancillary Base Sounder 45681-276 56<br />

Intelligent Open-Area Beacon Red Lens 55000-009 59<br />

Intelligent Open-Area Beacon Clear Lens 55000-010 59<br />

Loop-Powered Beacon Red 55000-877 59<br />

Loop-Powered Beacon Amber 55000-879 59<br />

Loop-Powered Beacon Clear Lens/Red Flash 55000-878 59<br />

Beacon Enclosure 29600-318 59<br />

Loop-Powered Beacon Base with Isolator 45681-333 61<br />

Loop-Powered Beacon Base with Standard Flash 45681-335 61<br />

Loop-Powered Beacon Base with Australian Flash 45681-337 61<br />

Intelligent Open-Area Sounder Beacon Red Lens 55000-005 63<br />

Intelligent Open-Area Sounder Beacon Clear Lens 55000-006 63<br />

Multi-Tone Open-Area Sounder Beacon Red with Isolator 55000-293 63<br />

Multi-Tone Open-Area Sounder Beacon White with Isolator 55000-294 63<br />

Multi-Tone Open-Area Sounder Beacon Red 55000-291 63<br />

Multi-Tone Open-Area Sounder Beacon White 55000-292 63<br />

Weatherproof Multi-Tone Open-Area Sounder Beacon Red with Isolator 55000-298 63<br />

Weatherproof Multi-Tone Open-Area Sounder Beacon White with Isolator 55000-299 63<br />

Weatherproof Multi-Tone Open-Area Sounder Beacon Red 55000-296 63<br />

Weatherproof Multi-Tone Open-Area Sounder Beacon White 55000-297 63<br />

Sounder Beacon Base with Isolator 45681-330 65<br />

Sounder Beacon Base 45681-331 65<br />

Sounder Beacon Base with Australian Tone 45681-336 65<br />

Sounder Beacon Base with Isolator DIN-Tone 45681-334 65<br />

Sounder Beacon Base with NZ Tone 45681-338 65<br />

Sounder Beacon Base Slow Whoop with Isolator 45681-332 65<br />

Magnetic Wand 29650-001 67


Intelligent <strong>Fire</strong> Detection<br />

DISCOVERY<br />

15


16 Intelligent <strong>Fire</strong> Detection<br />

XP95<br />

XP95<br />

intelligent fire<br />

<strong>detection</strong><br />

The XP95 range of intelligent fire<br />

detectors is advanced in design, improved<br />

in performance and has unique features<br />

that benefit the installer and end user.<br />

The range features smoke detectors (ionisation and optical),<br />

standard and high temperature heat detectors and a<br />

multisensor. Beam detectors, flame detectors, manual call<br />

points, audio visual signalling devices, interface units and<br />

isolators complete the range. XP95 has a ‘central intelligence’<br />

system where all the decisions are made by the control panel.<br />

Apollo has always used an open, digital protocol since 1986<br />

and has ensured backward compatibility when developing new<br />

products. An open protocol allows freedom of choice for the<br />

fire system specifier, installer and end user. A system using<br />

a digital protocol is also much less susceptible to corruption<br />

than an analogue protocol and is therefore often preferred in a<br />

system which is life critical.<br />

Key features of XP95 include:<br />

• Alarm Flag for fast alarm reporting<br />

• Alarm Address for fast location of alarm<br />

• XPERT card addressing<br />

• Electronics-free base<br />

• Easy installation<br />

• Elegant design<br />

• Insect Resistant


XP95 Ionisation Smoke Detector<br />

The XP95 Ionisation Smoke Detector uses a low<br />

activity radioactive foil to detect fires by irradiating<br />

the air in the smoke chambers and causing a<br />

current flow. If smoke enters the chamber, the<br />

current flow is reduced leading to an alarm.<br />

XP95 Ionisation Smoke Detector 55000-500<br />

XP95 Ionisation Smoke Detector (Black) 55000-660<br />

XP95 Ionisation Smoke Detector (VdS) 55000-520<br />

XP95 Optical Smoke Detector<br />

The XP95 Optical Smoke Detector works using the<br />

light scatter principle and is ideal for applications<br />

where slow-burning or smouldering fires are likely.<br />

XP95 Optical Smoke Detector 55000-600<br />

XP95 Optical Smoke Detector (Black) 55000-660<br />

XP95 Optical Smoke Detector (VdS) 55000-620<br />

XP95 Heat Detector<br />

The XP95 Heat Detector monitors temperature by<br />

using a single thermistor network which provides<br />

a count output proportional to the external air<br />

temperature. The XP95 range features two Heat<br />

Detectors, standard and high temperature. The<br />

standard heat detector is classified as an A2S<br />

device and will report an alarm at 55°C. The high<br />

temperature detector, classified as a CS device,<br />

will report an alarm at 90°C.<br />

XP95 Heat Detector A2S 55000-400<br />

XP95 Heat Detector A2S (VdS) 55000-420<br />

XP95 Heat Detector CS 55000-401<br />

XP95 Multisensor Detector<br />

The XP95 Multisensor Detector contains an optical<br />

smoke sensor and a thermistor temperature<br />

sensor whose outputs are combined to give the<br />

final analogue value.<br />

XP95 Multisensor Detector 55000-885<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

Intelligent <strong>Fire</strong> Detection<br />

XP95<br />

• Responds well to fast-burning, flaming fires<br />

• Designed to operate in a variety of<br />

environments<br />

• Minimal effects from temperature, humidity,<br />

atmospheric pressure<br />

• Well protected against electromagnetic<br />

interference over a wide frequency range<br />

• Responds well to slow-burning, smouldering<br />

fires<br />

• Well suited for bedrooms and escape routes<br />

• Unaffected by wind or atmospheric pressure<br />

• Ideal in environments that are dirty or smoky<br />

under normal conditions<br />

• Well suited for warehouses, loading bays and<br />

car parks<br />

• Unaffected by wind or atmospheric pressure<br />

• Sensitive to a wide range of fires<br />

• Well suited for environments such as hotel<br />

bedrooms<br />

• Unaffected by wind or atmospheric pressure<br />

17


18 Intelligent <strong>Fire</strong> Detection<br />

XP95<br />

Intelligent Mounting Base<br />

All detectors in the XP95 range fit the Intelligent<br />

Mounting Base. The Mounting Base is a low<br />

insertion force base with stainless steel contacts<br />

for the detector terminals. XPERT cards are<br />

supplied with all bases.<br />

Intelligent Mounting Base 45681-210<br />

Intelligent Mounting Base (Black) 45681-361<br />

Isolating Base<br />

The new style Isolating Base senses and detects<br />

short-circuit faults on XP95 loops and spurs.<br />

Isolating Base 45681-284<br />

Product will replace 45681-321 during 2009<br />

Isolator<br />

The Isolator is placed at intervals on the loop and<br />

ensures that, in the case of a short-circuit, only<br />

the section between the isolators will be affected.<br />

When the short-circuit is removed, the isolators<br />

automatically restore power and data to the<br />

isolated section.<br />

Isolator 55000-720<br />

Isolator Base<br />

The Isolator Base is unique and designed to only<br />

accept the Isolator 55000-720.<br />

Isolator Base 45681-211<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

• XPERT addressing<br />

• One way fit of detector<br />

• Locking feature to prevent unauthorised<br />

removal<br />

• The equivalent of up to 20 smoke detectors<br />

may be installed between isolating bases<br />

• High brightness LED<br />

• Detects wiring short circuits using patented<br />

technology<br />

• Minimises disruption from short-circuits<br />

• Automatic de-isolation on short-circuit removal<br />

• The equivalent of up to 20 smoke detectors<br />

may be installed between isolators<br />

• Only accepts isolators


Intelligent Low Power Relay Base<br />

The Low Power Relay Base incorporates a low<br />

power relay to control field <strong>equipment</strong> such as<br />

automatic door closers.<br />

Intelligent Low Power Relay Base 45681-242<br />

Intelligent Deep Base<br />

The Intelligent Deep Base is a mounting base for<br />

XP95 products which has an increased depth which<br />

allows for cables to be inserted into the side of the<br />

product.<br />

Intelligent Deep Base 45681-209<br />

Intelligent Heater Base<br />

The Intelligent Heater Base is designed to be used<br />

in cold climates where environmental conditions<br />

could result in either icing or condensation<br />

affecting the operation of detectors. It is<br />

recommended that the heater base be used in<br />

conjunction with either a Waterproof Base Cover<br />

or Deckhead Mounting Box to minimise moisture<br />

ingress.<br />

Intelligent Heater Base 45681-219<br />

Waterproof Base Cover 45681-519<br />

Deckhead Mounting Box 45681-217<br />

MiniDisc Remote Indicator<br />

The MiniDisc Remote Indicator is a light-weight,<br />

compact LED indicator for use in fire protection<br />

systems.<br />

MiniDisc Remote Indicator 53832-070<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

Intelligent <strong>Fire</strong> Detection<br />

• Enables surface wiring<br />

XP95<br />

• Gives a set of voltage free contacts controlled<br />

by the remote output of a detector<br />

• Draws negligible current<br />

• Capable of switching up to 30V at 1A<br />

• Raises the ambient temperature of a detector<br />

chamber by approximately 10°C<br />

• Limits the risk of potential for loss of<br />

functionality caused to detectors installed in<br />

these conditions.<br />

• Can be used across the entire Apollo range<br />

• Small and discrete<br />

• Anti-tamper screw to protect against<br />

unauthorised removal<br />

19


20 Intelligent <strong>Fire</strong> Detection<br />

XP95<br />

Ancillary devices available for the XP95 range:<br />

Product Name Part Number Page No.<br />

MOUNTING ACCESSORIES 82<br />

Backplate 45681-233 85<br />

Base Cover 45681-380 83<br />

Conduit Box 45681-204 83<br />

Sounder Ceiling Plate 45681-311 83<br />

Module Base 38531-822 83<br />

NEW!! Deckhead Mounting Box 45681-217 84<br />

Metal Deckhead Mounting Box PG16 29600-131 84<br />

Metal Deckhead Mounting Box M20 29600-139 84<br />

Deckhead Adaptor PG16-M20 27249-005 84<br />

Detector Ceiling Tile Mounting Box 45681-309 84<br />

Sounder Ceiling Tile Mounting Box 45681-310 84<br />

Beacon Enclosure 29600-318 84<br />

DIN-Rail Interface Enclosure (4 units) 29600-239 85<br />

DIN-Rail Interface Enclosure (10 units) 29600-240 85<br />

Series 90 to XP95 Base Adaptor 45681-238 85<br />

1.5mm Hexagonal Driver 29600-095 85<br />

MANUAL CALL POINTS 78<br />

XP95 Manual Call Point Red (Surface) 55100-905 79<br />

XP95 Manual Call Point with Isolator Red (Surface) 55100-908 79<br />

Transparent Hinged Cover 26729-152 79<br />

STANDARD INTERFACES 69<br />

Input/Output Unit 55000-847 70<br />

Three Channel Input/Output Unit 55000-588 70<br />

Three Channel Input/Output Unit PCB only 43781-588 70<br />

Output Unit 55000-849 70<br />

Sounder Control Unit 55000-852 70<br />

Switch Monitor 55000-843 71<br />

Switch Monitor Plus 55000-841 71<br />

Zone Monitor 55000-845 71<br />

MINI INTERFACES 73<br />

Mini Switch Monitor 55000-760 74<br />

Mini Switch Monitor with fly leads 55000-833 74<br />

Mini Switch Monitor with fly leads (Interrupt) 55000-832 74<br />

DIN-RAIL INTERFACES 75<br />

NEW!! DIN-Rail Mains Input/Output Unit 55000-797 76<br />

NEW!! DIN-Rail Sounder Controller (5 Amperes) 55000-182 76<br />

DIN-Rail Input/Output Unit 55000-803 76<br />

DIN-Rail Output Unit 55000-804 76<br />

DIN-Rail Switch Monitor 55000-822 76<br />

DIN-Rail Switch Monitor Plus 55000-821 77<br />

DIN-Rail Zone Monitor with Isolator 55000-812 77<br />

DIN-Rail Dual Isolator 55000-802 77<br />

AUDIO <strong>VIS</strong>UAL SIGNALLING 52<br />

Intelligent Open-Area Sounder Red 55000-001 54<br />

Intelligent Open-Area Sounder White 55000-002 54<br />

Intelligent 100dB (A) Open-Area Sounder Red 55000-278 54<br />

Intelligent 100dB (A) Open-Area Sounder White 55000-279 54<br />

Intelligent 100dB (A) Open-Area Sounder Slow Whoop Red 55000-276 54


Intelligent <strong>Fire</strong> Detection<br />

Product Name Part Number Page No.<br />

Intelligent 100dB (A) Open-Area Sounder Slow Whoop White 55000-277 54<br />

Intelligent 100dB (A) Open-Area Weatherproof Sounder Red 55000-274 54<br />

Intelligent 100dB (A) Open-Area Weatherproof Sounder White 55000-275 54<br />

Integrated Base Sounder 45681-278 56<br />

Integrated Base Sounder with Isolator 45681-277 56<br />

Integrated Base Sounder Slow Whoop 45681-291 56<br />

Integrated Base Sounder Slow Whoop with Isolator 45681-290 56<br />

Integrated Base Sounder DIN-Tone with Isolator 45681-300 56<br />

White Cap 45681-292 56<br />

Red Cap 45681-293 56<br />

Intelligent Base Sounder 45681-265 56<br />

Intelligent Base Sounder, for use with Isolating Base 45681-266 56<br />

Intelligent Base Sounder Slow Whoop 45681-267 56<br />

Intelligent Base Sounder Slow Whoop for use with Isolating Base 45681-268 56<br />

White Cap 29600-256 56<br />

Red Cap 29600-257 56<br />

Ancillary Base Sounder 45681-276 56<br />

Intelligent Open-Area Beacon Red Lens 55000-009 59<br />

Intelligent Open-Area Beacon Clear Lens 55000-010 59<br />

Loop-Powered Beacon Red 55000-877 59<br />

Loop-Powered Beacon Amber 55000-879 59<br />

Loop-Powered Beacon Clear Lens/Red Flash 55000-878 59<br />

Beacon Enclosure 29600-318 59<br />

Loop-Powered Beacon Base with Isolator 45681-333 61<br />

Loop-Powered Beacon Base with Standard Flash 45681-335 61<br />

Loop-Powered Beacon Base with Australian Flash 45681-337 61<br />

Intelligent Open-Area Sounder Beacon Red Lens 55000-005 63<br />

Intelligent Open-Area Sounder Beacon Clear Lens 55000-006 63<br />

Multi-Tone Open-Area Sounder Beacon Red with Isolator 55000-293 63<br />

Multi-Tone Open-Area Sounder Beacon White with Isolator 55000-294 63<br />

Multi-Tone Open-Area Sounder Beacon Red 55000-291 63<br />

Multi-Tone Open-Area Sounder Beacon White 55000-292 63<br />

Weatherproof Multi-Tone Open-Area Sounder Beacon Red with Isolator 55000-298 63<br />

Weatherproof Multi-Tone Open-Area Sounder Beacon White with Isolator 55000-299 63<br />

Weatherproof Multi-Tone Open-Area Sounder Beacon Red 55000-296 63<br />

Weatherproof Multi-Tone Open-Area Sounder Beacon White 55000-297 63<br />

Sounder Beacon Base with Isolator 45681-330 65<br />

Sounder Beacon Base 45681-331 65<br />

Sounder Beacon Base with Australian Tone 45681-336 65<br />

Sounder Beacon Base with Isolator DIN-Tone 45681-334 65<br />

Sounder Beacon Base with NZ Tone 45681-338 65<br />

Sounder Beacon Base Slow Whoop with Isolator 45681-332 65<br />

XP95<br />

21


22 Intelligent <strong>Fire</strong> Detection<br />

XPERT CARDS<br />

XPERT<br />

cards<br />

intelligent fire<br />

<strong>detection</strong><br />

Apollo’s Intelligent ranges use patented<br />

XPERT cards. A unique XPERT card provides<br />

simple, user friendly and accurate<br />

identification of detector location where a<br />

coded card, inserted into the base, is read<br />

by any detector once plugged in. All the<br />

electronic components are in the detector<br />

but the location information is held in<br />

the base which saves time and increases<br />

accuracy during commissioning.


Blank XPERT Card<br />

A universal address card supplied with all bases.<br />

Using a coding guide, pips are removed to set the<br />

address of the inserted detector.<br />

Blank XPERT Card 38531-771<br />

Pre-Addressed XPERT Cards<br />

Pre-addressed XPERT cards are supplied with pips<br />

already removed.<br />

Pre-Addressed XPERT Cards 1-126 45682-127<br />

XPander XPERT Cards<br />

Intelligent <strong>Fire</strong> Detection<br />

XPERT CARDS<br />

• Simplifies and speeds up installation and<br />

commissioning<br />

• Uses patented, proven technology<br />

• Address remains the same, no matter how<br />

often detectors are replaced<br />

• Flexibility to create any address<br />

• Saves time and increases accuracy during<br />

commissioning<br />

• Uses patented, proven technology<br />

• Address remains the same, no matter how<br />

often detectors are replaced<br />

Product Name Part Number<br />

XPander Blank XPERT Card (White) 29600-413<br />

XPander Blank XPERT Card (Red) 29600-399<br />

XPander XPERT cards are not interchangeable with those used with XP95 and Discovery.<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

23


10 24<br />

Conventional <strong>Fire</strong> Detection<br />

Conventional<br />

<strong>Fire</strong><br />

Detection<br />

In conventional systems detectors are wired as<br />

a circuit or ‘zone’. They signal fire conditions to<br />

a control panel by changing from a high to low<br />

impedance. The panel detects this impedance<br />

change by current monitoring and identifies the<br />

zone. Individual detectors cannot be identified.


Orbis is a range of conventional<br />

detectors which has been developed<br />

with sophisticated technology previously<br />

only found in intelligent detectors. Orbis<br />

is a range with modern styling and<br />

incorporates a mounting base which<br />

saves installation time.<br />

Key features of Orbis:<br />

• Automatic drift compensation with DirtAlert ® warning<br />

• Patented FasTest ® which reduces the time taken to test<br />

detectors<br />

• SensAlert ® uses a flashing LED to indicate that the<br />

sensor is not operating correctly<br />

• StartUp for fast commissioning<br />

• Attractive and compact design<br />

• Electrically compatible with Series 60 and Series 65<br />

• Wide voltage and operating temperature ranges<br />

• Algorithms for transient rejection<br />

• Flashing LED option<br />

• 360° visibility of LEDs<br />

• Insect Resistant<br />

Conventional <strong>Fire</strong> Detection 11 25<br />

ORBIS<br />

Orbis<br />

conventional<br />

fire <strong>detection</strong>


10 26<br />

Conventional <strong>Fire</strong> Detection<br />

ORBIS<br />

Orbis Optical Smoke Detector<br />

The Orbis Optical Smoke Detector works using the<br />

well established light scatter principle, however,<br />

the sensing technology is radically different<br />

in design from previous optical detectors and<br />

significantly reduces false alarms.<br />

Orbis Optical Smoke Detector ORB-OP-12001-APO<br />

Orbis Optical Smoke Detector ORB-OP-12003-APO<br />

with flashing LED †<br />

Orbis Multisensor Detector<br />

The Orbis Multisensor detector benefits from<br />

the same false alarm reduction technology as<br />

the optical detector. It is a thermally enhanced<br />

smoke detector and so will not give an alarm<br />

from heat alone.<br />

Orbis Multisensor Detector ORB-OH-13001-APO<br />

Orbis Multisensor Detector ORB-OH-13003-APO<br />

with flashing LED †<br />

Orbis Heat Detector<br />

The Orbis Heat Detector monitors temperature by<br />

using a single thermistor network which provides<br />

a voltage output proportional to the external air<br />

temperature. There are seven classes of heat<br />

detectors in the Orbis range designed to suit a<br />

wide variety of operating conditions.<br />

Orbis Heat Detector<br />

Rate-of-Rise, MAT 50°C<br />

A1R - Standard ORB-HT-11001-APO<br />

A1R - with flashing LED †<br />

Static, MAT 50°C<br />

ORB-HT-11013-APO<br />

A1S - Standard ORB-HT-11166-APO<br />

A1S with flashing LED † ORB-HT-11167-APO<br />

A2S - Standard ORB-HT-11002-APO<br />

A2S - with flashing LED †<br />

Rate-of-Rise, MAT 65°C<br />

ORB-HT-11014-APO<br />

BR - Standard ORB-HT-11003-APO<br />

BR - with flashing LED †<br />

Static, MAT 65°C<br />

ORB-HT-11015-APO<br />

BS - Standard ORB-HT-11004-APO<br />

BS - with flashing LED †<br />

Rate-of-Rise, MAT 80°C<br />

ORB-HT-11016-APO<br />

CR - Standard ORB-HT-11005-APO<br />

CR - with flashing LED †<br />

Static, MAT 80°C<br />

ORB-HT-11017-APO<br />

CS - Standard ORB-HT-11006-APO<br />

CS - with flashing LED † ORB-HT-11018-APO<br />

MAT (Maximum Application Temperature)<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

† Does not have VdS approval<br />

• Responds well to slow-burning, smouldering fires<br />

• Performs well in black and white smoke<br />

• Extra confirmation of smoke before alarm<br />

signal is given<br />

• Reduced incidence of false alarms<br />

• Sensing chamber keeps out dust and other<br />

airborne contaminants<br />

• Operates over a broad range of voltages at<br />

extremes of temperature<br />

• Responds well to fast-burning, flaming fires<br />

• Reduced incidence of false alarms<br />

• Increased reliability of <strong>detection</strong><br />

• Sensing chamber keeps out dust and other<br />

airborne contaminants<br />

• Operates over a broad range of voltages at<br />

extremes of temperature<br />

• Can be used for applications where smoke<br />

detectors are unsuitable<br />

• Ideal in environments that are dirty or smoky<br />

under normal conditions<br />

• Reduced incidence of false alarms<br />

• Increased reliability of <strong>detection</strong><br />

Choosing a heat detector


Orbis LX Base<br />

The Orbis LX Base is a low cost mounting base for<br />

use with Orbis detectors.<br />

Orbis LX Base ORB-MB-00012-APO<br />

TimeSaver Base ®<br />

The TimeSaver Base ® is a completely new design<br />

that provides installers with an open working<br />

area with fixing holes shaped to allow a simple<br />

mounting procedure.<br />

TimeSaver Base ® ORB-MB-00001-APO<br />

TimeSaver Base ® LX<br />

(simplified) version<br />

ORB-MB-00002-APO<br />

TimeSaver Diode Base<br />

The TimeSaver Diode Base has the same design as<br />

the standard TimeSaver Base ® with the addition of<br />

a diode. It is used in systems which house active<br />

EOL monitoring for head removal.<br />

TimeSaver Diode Base ORB-DB-00003-APO<br />

TimeSaver Relay Base<br />

The TimeSaver Relay Base incorporates a singlepole<br />

voltage-free change-over contact for switching<br />

external <strong>equipment</strong>. When the detector changes<br />

to the alarm state, the relay is energised, causing<br />

the contact to change state. The contact will<br />

remain in this condition until the detector is reset.<br />

TimeSaver Relay Base ORB-RB-10004-APO<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

Conventional <strong>Fire</strong> Detection 11 27<br />

• Low cost option<br />

• Grouped terminals to make wiring easy<br />

• Two fixing centres<br />

• LED alignment mark<br />

• Cable stripping guide<br />

• Detector locking mechanism<br />

• Grouped terminals to make wiring easy<br />

• Two fixing centres<br />

• LED alignment mark<br />

• Cable stripping guide<br />

• Continuity link for voltage testing of zone<br />

wiring prior to commissioning<br />

• Detector locking mechanism<br />

• Other devices continue to work during<br />

unauthorised removal of detectors<br />

• Grouped terminals to make wiring easy<br />

• Two fixing centres<br />

• LED alignment mark<br />

• Cable stripping guide<br />

• Continuity link for voltage testing of zone<br />

wiring prior to commissioning<br />

• Detector locking mechanism<br />

• Capable of switching up to 30V at 1A<br />

ORBIS


10 28<br />

Conventional <strong>Fire</strong> Detection<br />

ORBIS<br />

Sav-Wire Base<br />

The Sav-Wire Base is designed to allow Orbis<br />

detectors to be used in ‘Sav-Wire’ <strong>detection</strong> and<br />

alarm systems.<br />

Sav-Wire Base ORB-SW-10005-APO<br />

TimeSaver Deep Base<br />

The TimeSaver Deep Base is a mounting base<br />

for Orbis products which has an increased depth<br />

which allows for cables to be inserted into the<br />

side of the product.<br />

TimeSaver Deep Base ORB-MB-00019-APO<br />

Orbis Heater Base<br />

The Orbis Heater base is designed to be used in<br />

cold climates where environmental conditions could<br />

result in either icing or condensation affecting the<br />

operation of detectors. It is recommended that<br />

the heater base be used in conjunction with either<br />

a Waterproof Base Cover or Deckhead Mounting<br />

Box to minimise moisture ingress.<br />

Orbis Heater Base ORB-HB-00020-APO<br />

Waterproof Base Cover 45681-519<br />

Deckhead Mounting Box 45681-217<br />

MiniDisc Remote Indicator<br />

The MiniDisc Remote Indicator is a light-weight,<br />

compact LED indicator for use in fire protection<br />

systems.<br />

MiniDisc Remote Indicator 53832-070<br />

Ancillary devices available for the Orbis range:<br />

• Grouped terminals to make wiring easy<br />

• Two fixing centres<br />

• LED alignment mark<br />

• Cable stripping guide<br />

• Detector locking mechanism<br />

• Can be used in ‘Sav-Wire’ systems<br />

• Enables surface wiring<br />

• Raises the ambient temperature of a detector<br />

chamber by approximately 10°C<br />

• Limits the risk of potential for loss of<br />

functionality caused to detectors installed in<br />

these conditions.<br />

• Can be used across the entire Apollo range<br />

• Small and discrete<br />

• Anti-tamper screw to protect against<br />

unauthorised removal<br />

Product Name Part Number Page No.<br />

MOUNTING ACCESSORIES 82<br />

Backplate 45681-233 85<br />

Conduit Box 45681-204 83<br />

Sounder Ceiling Plate 45681-311 83<br />

Polycarbonate Deckhead Mounting Box 45681-217 84<br />

Metal Deckhead Mounting Box PG16 29600-131 84<br />

Metal Deckhead Mounting Box M20 29600-139 84<br />

Deckhead Adaptor PG16-M20 27249-005 84<br />

Detector Ceiling Tile Mounting Box 45681-309 84<br />

Sounder Ceiling Tile Mounting Box 45681-310 84<br />

1.5mm Hexagonal Driver 29600-095 85<br />

Series 65 to Orbis Base Adaptor ORB-BA-10008-APO 85<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.


Series 65 incorporates well-proven<br />

sensing technologies together with<br />

advances in materials and electronics.<br />

Developed from the highly successful<br />

Series 60 range of detectors, Series<br />

65 includes a chip (integrated circuit)<br />

based on that used in XP95 analogue<br />

addressable detectors.<br />

Having a wide operating voltage of 9-33V, the Series 65<br />

detectors can be integrated into security systems, when used<br />

with a relay base. The range consists of ionisation, integrating<br />

ionisation and optical smoke detectors, four grades of heat<br />

detector and a range of bases.<br />

Each type of detector is available in three versions:<br />

• Standard<br />

• Flashing LED<br />

• Flashing LED and magnet operated test switch<br />

Key features of Series 65:<br />

• Wide operating voltage<br />

• Advanced electronic technology<br />

• Flashing LED option<br />

• Magnetic test switch option<br />

• Can be used on security systems<br />

• Electrically and mechanically compatible with Series 60<br />

• Proven <strong>detection</strong> performance<br />

Conventional <strong>Fire</strong> Detection 11 29<br />

SERIES 65<br />

Series 65<br />

conventional fire<br />

<strong>detection</strong>


10 30<br />

Conventional <strong>Fire</strong> Detection<br />

SERIES 65<br />

Series 65 Ionisation Smoke Detector<br />

The Series 65 Ionisation Smoke Detector uses a low<br />

activity radioactive foil to detect fires by irradiating<br />

the air in the smoke chambers and causing a<br />

current flow. If smoke enters the chamber, the<br />

current flow is reduced leading to an alarm.<br />

Series 65 Ionisation Smoke Detector 55000-217<br />

Series 65 Ionisation Smoke Detector 55000-216<br />

with flashing LED †<br />

Series 65 Ionisation Smoke Detector 55000-215<br />

with flashing LED and magnetic test switch †<br />

Series 65 Ionisation Smoke Detector 55000-208<br />

(French)*<br />

Series 65 Integrating Ionisation<br />

Smoke Detector<br />

Ionisation detectors use a low activity radioactive<br />

foil to detect fires by irradiating the air in the<br />

smoke chambers and causing a current flow.<br />

If smoke enters the chamber, the current flow<br />

is reduced leading to an alarm. Circuitry in the<br />

integrating Ionisation Smoke Detector protects<br />

against transient levels of smoke above the<br />

normal threshold for up to 20 seconds.<br />

Series 65 Integrating Ionisation 55000-220<br />

Smoke Detector<br />

Series 65 Integrating Ionisation 55000-219<br />

Smoke Detector with flashing LED †<br />

Series 65 Integrating Ionisation 55000-218<br />

Smoke Detector with flashing LED<br />

and magnetic test switch †<br />

Series 65 Optical Smoke Detector<br />

The Series 65 Optical Smoke Detector incorporates<br />

a pulsing LED located within the housing of the<br />

detector. The external detector moulding is<br />

identical to that of the ionisation detector but has<br />

an indicator LED which is clear in quiescent state<br />

but produces red light in alarm.<br />

Series 65 Optical Smoke Detector 55000-317<br />

Series 65 Optical Smoke Detector 55000-316<br />

with flashing LED †<br />

Series 65 Optical Smoke Detector with 55000-315<br />

flashing LED and magnetic test switch †<br />

Series 65 Optical Smoke Detector 55000-308<br />

(French)*<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

† Does not have VdS approval<br />

* Does not have LPCB or VdS approval<br />

• Responds well to fast burning, flaming fires<br />

• Designed to operate in a variety of<br />

environments<br />

• Wide operating voltage<br />

• Flashing LED and magnet operated test<br />

switch option<br />

• Responds well to fast burning, flaming fires<br />

• Designed to operate in environments where<br />

transient levels of smoke may be expected<br />

• Wide operating voltage<br />

• Flashing LED and magnet operated test<br />

switch option<br />

• Responds well to slow-burning, smouldering<br />

fires<br />

• Well suited for bedrooms and escape routes<br />

• Unaffected by wind or atmospheric pressure<br />

• Wide operating voltage<br />

• Flashing LED and magnet operated test<br />

switch option


Series 65 Heat Detector<br />

The Series 65 Heat Detector monitors temperature<br />

by using a dual thermistor network which provides<br />

a voltage output proportional to the external air<br />

temperature. There are 12 heat detectors in the<br />

Series 65 range designed to suit a wide variety of<br />

operating conditions.<br />

Series 65 Heat Detector<br />

Rate-of-Rise, MAT 50°C, MSRT 65°C<br />

A1R - Standard 55000-122<br />

A1R - flashing LED † 55000-121<br />

A1R - flashing LED and magnetic test † 55000-120<br />

Rate of Rise, MAT 65°C, MSRT 85°C<br />

BR - Standard 55000-127<br />

BR - flashing LED † 55000-126<br />

BR - flashing LED and magnetic test † 55000-125<br />

Rate-of-Rise, MAT 80°C, MSRT 100°C<br />

CR - Standard 55000-132<br />

CR - flashing LED † 55000-131<br />

CR - flashing LED and magnetic test † 55000-130<br />

Static, MAT 80°C, MSRT 100°C<br />

CS - Standard 55000-137<br />

CS - flashing LED † 55000-136<br />

CS - flashing LED and magnetic test † 55000-135<br />

MAT (Maximum Application Temperature)<br />

MSRT (Maximum Static Response Temperature)<br />

Series 65 Standard Base<br />

The Series 65 Standard Base has been designed<br />

to enable detectors to be fitted without the<br />

need of force – particularly useful when fitting<br />

to suspended ceilings. All Series 65 bases have<br />

a ‘one way only’ fit. They can be locked into<br />

place by a grub screw using a 1.5mm hexagonal<br />

screwdriver - part number 29600-095.<br />

Series 65 Standard Base 45681-200<br />

Series 65 Diode Base<br />

The Series 65 Diode Base is designed for use with<br />

conventional systems that have manual call points<br />

and detector bases on the same circuit. The base<br />

is fitted with a schottky diode on the “L1 IN” and<br />

“L1 OUT” wiring terminals. This base can only be<br />

used with compatible control <strong>equipment</strong>.<br />

Series 65 Diode Base 45681-201<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

† Does not have VdS approval<br />

Conventional <strong>Fire</strong> Detection 11 31<br />

SERIES 65<br />

• Can be used for applications where smoke<br />

detectors are unsuitable<br />

• Ideal environments that are dirty or smoky<br />

under normal conditions<br />

• Wide operating voltage<br />

• Flashing LED and magnet operated test<br />

switch option<br />

• Detector locking mechanism<br />

• One way fit<br />

• Easy to wire<br />

• Contains an earth connector<br />

• Contains no electrical parts<br />

• Detector locking mechanism<br />

• One way fit<br />

• Easy to wire<br />

• Contains an earth connector<br />

• Continues to work during unauthorised<br />

removal of detectors


10 32<br />

Conventional <strong>Fire</strong> Detection<br />

SERIES 65<br />

Series 65 Sav-Wire Base<br />

The Series 65 Sav-Wire Base is designed to allow<br />

Series 65 detectors to be used in ‘Sav-Wire’<br />

<strong>detection</strong> and alarm systems.<br />

Series 65 Sav-Wire Base 45681-206<br />

Series 65 Standard Relay Base<br />

The Series 65 Standard Relay Base provides one<br />

set of volt-free, changeover (form C) contacts that<br />

change state when the detector signals an alarm.<br />

Series 65 Standard Relay Base 45681-245<br />

Series 65 Auxiliary Relay Base<br />

The Series 65 Auxiliary Relay Base provides two<br />

sets of volt-free changeover contacts to facilitate<br />

the switching of a remote LED or other auxiliary<br />

device.<br />

Series 65 Auxiliary Relay Base 45681-246<br />

Series 65 End-of-Line Relay Base<br />

The Series 65 End-of-Line (EOL) Relay Base is<br />

intended for use with 4-wire circuits and features<br />

two sets of changeover contacts and a power<br />

supervision relay.<br />

Series 65 End-of-Line Relay Base 12V 45681-247<br />

Series 65 End-of-Line Relay Base 24V 45681-248<br />

Series 65 12V Relay Base<br />

The Series 65 12V Relay Base is designed for use<br />

in both fire and security systems. For fire systems<br />

a jumper on the PCB is fitted to a ‘latching’<br />

position. For security systems the jumper is<br />

moved to another position so that the base is<br />

non-latching.<br />

Series 65 12V Relay Base 45681-508<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

• Detector locking mechanism<br />

• One way fit<br />

• Easy to wire<br />

• Contains an earth connector<br />

• Detects the removal of a detector head and<br />

reports a fault<br />

• Detector locking mechanism<br />

• One way fit<br />

• Easy to wire<br />

• Contains an earth connector<br />

• Detector locking mechanism<br />

• One way fit<br />

• Easy to wire<br />

• Contains an earth connector<br />

• Detector locking mechanism<br />

• One way fit<br />

• Easy to wire<br />

• Contains an earth connector<br />

• Detector locking mechanism<br />

• One way fit<br />

• Easy to wire<br />

• Contains an earth connector<br />

• Can be used in fire and security systems


MiniDisc Remote Indicator<br />

The MiniDisc Remote Indicator is a light-weight,<br />

compact LED indicator for use in fire protection<br />

systems.<br />

MiniDisc Remote Indicator 53832-070<br />

Ancillary devices available for the Series 65 range:<br />

Conventional <strong>Fire</strong> Detection 11 33<br />

SERIES 65<br />

• Can be used across the entire Apollo range<br />

• Small and discrete<br />

• Anti-tamper screw to protect against<br />

unauthorised removal<br />

Product Name Part Number Page No.<br />

MOUNTING ACCESSORIES 82<br />

Backplate 45681-233 85<br />

Series 65 Base Cover 45681-370 83<br />

Conduit Box 45681-204 83<br />

Module Base 38531-822 83<br />

Metal Deckhead Mounting Box PG16 29600-131 84<br />

Metal Deckhead Mounting Box M20 29600-139 84<br />

Deckhead Adaptor PG16-M20 27249-005 84<br />

Detector Ceiling Tile Mounting Box 45681-309 84<br />

1.5mm Hexagonal Driver 29600-095 85<br />

AUDIO <strong>VIS</strong>UAL SIGNALLING 52<br />

Series 65 Sounder Base 45681-512 57<br />

Series 65 Sounder Base with diode 45681-513 57<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.


10 34<br />

Two-Wire Technology<br />

Two-Wire<br />

Technology<br />

In conventional systems, detectors are hard wired<br />

into a circuit or zone. They signal a fire condition<br />

to a control panel by changing from a high to low<br />

impedance. The panel detects this impedance<br />

change by current monitoring and identifies the<br />

zone. Individual detectors cannot be identified. In<br />

two-wire conventional systems, fire <strong>detection</strong> and<br />

alarm products are connected to the same pair<br />

of supply wires, making installation quicker, less<br />

expensive and more flexible than traditional fourwire<br />

systems. Two-wire systems are particularly<br />

well suited for small to medium sized buildings.


AlarmSense has been developed to<br />

make the design and installation of a<br />

fire <strong>detection</strong> and alarm system easier<br />

and more economic for small to medium<br />

sized buildings. The range also allows<br />

an existing system to be extended or<br />

modified if necessary. This flexibility<br />

makes AlarmSense an excellent choice<br />

for use in HMOs.<br />

The AlarmSense range incorporates a number of technologically<br />

advanced features such as patented RemovAlert which<br />

alerts the control panel if a detector has been removed<br />

without authorisation.<br />

The entire AlarmSense range has been designed to enable<br />

compliance with BS5839-1 and BS5839-6 in addition to EN54<br />

standards. AlarmSense is also compliant with the Construction<br />

Products Directive (CPD).<br />

Key features of AlarmSense include:<br />

• Patented RemovAlert head removal monitoring<br />

• Local and general alarm switching<br />

• Reduced wiring costs<br />

• Quick and simple installation<br />

• False alarm reduction with ‘non-priority’ signalling<br />

• Flexible system design<br />

• Failsafe operation of manual call points<br />

• Detectors and call point alarms identifiable separately<br />

Two-Wire Technology 11 35<br />

ALARMSENSE<br />

AlarmSense<br />

two-wire<br />

technology


10 36<br />

Two-Wire Technology<br />

ALARMSENSE<br />

AlarmSense Optical Smoke Detector<br />

The AlarmSense Optical Smoke Detector works<br />

using the light scatter principle. The detector<br />

changes to alarm state at a pre-set threshold of<br />

smoke penetration into the sensing chamber.<br />

AlarmSense Optical Smoke Detector 55000-390<br />

AlarmSense Integrating Optical<br />

Smoke Detector<br />

The AlarmSense Integrating Optical Smoke<br />

Detector works using the light scatter principle.<br />

The detector changes to alarm state at a pre-set<br />

threshold of smoke penetration into the sensing<br />

chamber. The detector also has the ability to<br />

monitor and discard transient sources of smoke.<br />

AlarmSense Integrating 55000-391<br />

Optical Smoke Detector<br />

AlarmSense Heat Detector<br />

There are two heat detectors in the AlarmSense<br />

range designed to suit a wide variety of operating<br />

conditions. A static heat detector (CS) which<br />

responds only when a fixed temperature has been<br />

reached and a rate-of-rise detector (A1R) which<br />

has a fixed upper limit, but in addition, measures<br />

the rate of increase in temperature.<br />

AlarmSense Heat Detector A1R 55000-190<br />

AlarmSense Heat Detector CS 55000-193<br />

AlarmSense Base<br />

AlarmSense detectors can only be mounted into<br />

the AlarmSense Base. The base is used for installing<br />

detectors that do not require an integral sounder or<br />

sounder beacon.<br />

AlarmSense Base 45681-244<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

• Responds well to slow-burning, smouldering fires<br />

• Well suited for bedrooms and escape routes<br />

• 360° visibility of LEDs<br />

• Reduces false alarms<br />

• Quick and simple installation<br />

• Responds well to slow-burning, smouldering fires<br />

• Well suited for bedrooms and escape routes<br />

• 360° visibility of LEDs<br />

• Quick and simple installation<br />

• Designed to operate in environments where<br />

transient levels of smoke may be expected<br />

• Reduces false alarms<br />

• Can be used for applications where smoke<br />

detectors are unsuitable<br />

• Ideal environments that are dirty or smoky<br />

under normal conditions<br />

• CS detectors are ideal for use in environments<br />

with rapid temperature fluctuations such as<br />

boiler rooms<br />

• Reduction of false alarms<br />

• 360° visibility of LEDs<br />

• Quick and simple installation<br />

• Detects the removal of a detector head and<br />

reports a fault<br />

• Continues to work during unauthorised<br />

removal of detectors<br />

• Quick and simple installation


AlarmSense Alarm Relay<br />

The AlarmSense Alarm Relay enables devices such<br />

as beacons, pillow/bed alarms and radio vibrating or<br />

paging devices to be connected to the fire <strong>detection</strong><br />

system. This allows the system to comply with the<br />

requirements of the DDA.<br />

AlarmSense Alarm Relay 55000-835<br />

MiniDisc Remote Indicator<br />

The MiniDisc Remote Indicator is a light-weight,<br />

compact LED indicator for use in fire protection<br />

systems.<br />

MiniDisc Remote indicator 53832-070<br />

AlarmSense Manual Call Point<br />

The AlarmSense Manual Call Point is compliant<br />

with EN54:11. It is different from other<br />

conventional call points in that it can be detected<br />

as an operated call point rather than a detector<br />

that has changed to the alarm state.<br />

AlarmSense Manual Call Point 55100-894<br />

(Surface)<br />

AlarmSense Sounder Base<br />

The AlarmSense Sounder Base can only be<br />

used with AlarmSense detectors. It is fitted with<br />

electronic circuitry to monitor the presence of<br />

detectors and signals any unauthorised removal<br />

of detector heads. It is supplied with a high or low<br />

volume setting and red or white caps are available<br />

for stand-alone installation<br />

AlarmSense Sounder Base LR 45681-341<br />

AlarmSense Sounder Base 45681-510<br />

Red Cap 45681-295<br />

White Cap 45681-294<br />

AlarmSense Sounder Beacon Base<br />

The AlarmSense Sounder Beacon Base is designed<br />

to be used with AlarmSense detectors only.<br />

AlarmSense Sounder Beacon Base LR 45681-340<br />

AlarmSense Sounder Beacon Base 45681-509<br />

Red Cap 45681-295<br />

White Cap 45681-294<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

Two-Wire Technology 11 37<br />

• Ensures DDA compliance<br />

ALARMSENSE<br />

• Can be used across the entire Apollo range<br />

• Small and discrete<br />

• Anti-tamper screw to protect against<br />

unauthorised removal<br />

• Gives immediate response<br />

• Unique identification signalling<br />

• Resettable element<br />

• Detects the removal of a detector head and<br />

reports a fault<br />

• Continues to work during unauthorised<br />

removal of detectors<br />

• Quick and simple installation<br />

• Provides audible signal and <strong>detection</strong> at<br />

one point<br />

• High and low volume ranges<br />

• Sounder range between 70dB(A) and 87dB(A)<br />

• Detects the removal of a detector head and<br />

reports a fault<br />

• Continues to work during unauthorised<br />

removal of detectors<br />

• Quick and simple installation


10 38<br />

Two-Wire Technology<br />

ALARMSENSE<br />

Ancillary devices available for the AlarmSense range:<br />

Product Name Part Number Page No.<br />

MOUNTING ACCESSORIES 82<br />

Backplate 45681-233 83<br />

Conduit Box 45681-204 83<br />

Sounder Ceiling Plate 45681-311 83<br />

Module Base 38531-822 83<br />

Metal Deckhead Mounting Box PG16 29600-131 84<br />

Metal Deckhead Mounting Box M20 29600-139 84<br />

Deckhead Adaptor PG16 - M20 27249-005 84<br />

Detector Ceiling Tile Mounting Box 45681-309 84<br />

Sounder Ceiling Tile Mounting Box 45681-310 84<br />

1.5mm Hexagonal Driver 29600-095 85<br />

MANUAL CALL POINTS 78<br />

AlarmSense Manual Call Point (Surface) 55100-894 80<br />

AlarmSense Manual Call Point (Flush) 55100-893 80<br />

AUDIO <strong>VIS</strong>UAL SIGNALLING 52<br />

AlarmSense Sounder Base LR 45681-341 57<br />

AlarmSense Sounder Base 45681-510 57<br />

AlarmSense Sounder Beacon Base LR 45681-340 65<br />

AlarmSense Sounder Beacon Base 45681-509 65<br />

White Cap 45681-294 65<br />

Red Cap 45681-295 65<br />

Apollo makes ordering AlarmSense products for a project easy with a<br />

selection of detector/sounder base or detector/sounder beacon base<br />

packages. See pages 57 and 65 for a description of the AlarmSense<br />

Sounder Base and Sounder Beacon Base.<br />

Sounder Base Combination Part Number<br />

With Optical Smoke Detector 55000-392<br />

With Integrating Optical Smoke Detector 55000-393<br />

With A1R Heat Detector 55000-196<br />

With CS Heat Detector 55000-197<br />

Sounder Beacon Base Combination Part Number<br />

With Optical Smoke Detector 55000-394<br />

With Integrating Optical Smoke Detector 55000-395<br />

With A1R Heat Detector 55000-198<br />

With CS Heat Detector 55000-199


Two-Wire Technology 11 39<br />

ALARMSENSE


10 40<br />

Wireless Technology<br />

Wireless<br />

Technology<br />

Traditionally, fire <strong>detection</strong> systems in industrial<br />

and commercial applications have used hard wired<br />

installations. These systems are generally installed<br />

at the time of construction or refurbishment,<br />

making the laying of cables less of an issue. Certain<br />

applications do not lend themselves to this approach,<br />

such as occupied buildings, heritage sites, palaces,<br />

annexes etc. - this is where wireless systems<br />

provide the ideal solution.


XPander is a system in which individual<br />

detectors, call points and alarm devices<br />

communicate with the XP95 loop by<br />

radio signals. An interface is connected<br />

to the loop in the same way as any other<br />

interface, such as an input/output unit.<br />

Every XPander device is assigned an address and this<br />

address is recognised by the control panel in the same<br />

way as the address of any other device connected directly<br />

to the loop wiring. The XPander range benefits from the<br />

patented XPERT technology that is also used in Discovery<br />

and XP95. See page 23 for more details.<br />

XPander can be incorporated into fire <strong>detection</strong> systems in<br />

stately homes and architecturally sensitive buildings where<br />

the use of fire cables is either impractical or undesirable.<br />

Key features of XPander include:<br />

• Easy to install<br />

• XPERT card addressing<br />

• Self-monitoring<br />

• Proven technology<br />

• No special control panel needed<br />

• 868MHz radio channels<br />

• Up to 15 devices per interface<br />

• Up to 5 interfaces per loop<br />

All detectors within the XPander range are sold with<br />

mounting bases.<br />

Please ensure that you have attended an approved XPander<br />

training course prior to purchasing products from the<br />

XPander range.<br />

A site survey tool must be included in the first order of<br />

XPander products as a site survey must be carried out prior<br />

to installation.<br />

Wireless Technology 11 41<br />

XPANDER<br />

XPander<br />

wireless technology


10 42<br />

Wireless Technology<br />

XPANDER<br />

XPander Optical Smoke Detector<br />

and Mounting Base<br />

The XPander Optical Smoke Detector works on the<br />

light scatter principle and is ideal for applications<br />

where slow-burning or smouldering fires are likely.<br />

XPander Optical Smoke Detector<br />

and Mounting Base XPA-CB-12034-APO<br />

XPander Multisensor Detector and<br />

Mounting Base<br />

The XPander Multisensor Detector contains<br />

an optical smoke sensor and a thermistor<br />

temperature sensor whose outputs are combined<br />

to give the final analogue value.<br />

XPander Multisensor Detector<br />

and Mounting Base XPA-CB-13032-APO<br />

XPander Heat Detector and<br />

Mounting Base<br />

There are two heat detectors in the XPander<br />

range designed to suit a wide variety of operating<br />

conditions. A static heat detector (CS) which<br />

responds only when a fixed temperature has been<br />

reached and a rate-of-rise detector (A1R) which<br />

has a fixed upper limit, but in addition, measures<br />

the rate of increase in temperature.<br />

XPander Heat Detector and Mounting Base<br />

Rate-of-Rise (A1R) XPA-CB-11170-APO<br />

Static (CS) XPA-CB-11171-APO<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

• Responds well to slow-burning, smouldering<br />

fires<br />

• Well suited for bedrooms and escape routes<br />

• Modified to function with the low current<br />

requirements of radio systems<br />

• Bi-directional (monitored) radio platform<br />

• Easy to install<br />

• Powered by two independent packs of 3 AA<br />

alkaline batteries with a typical three year life<br />

• Sensitive to a wide range of fires<br />

• Well suited for environments such as hotel<br />

bedrooms<br />

• Modified to function with the low current<br />

requirements of radio systems<br />

• Bi-directional (monitored) radio platform<br />

• Easy to install<br />

• Powered by two independent packs of 3 AA<br />

alkaline batteries with a typical three year life<br />

• Can be used in applications where smoke<br />

detectors are unsuitable<br />

• Ideal environments that are dirty or smoky<br />

under normal conditions<br />

• CS detectors are ideal for use in environments<br />

with rapid temperature fluctuations such as<br />

boiler rooms<br />

• Modified to function with the low current<br />

requirements of radio systems<br />

• Bi-directional (monitored) radio platform<br />

• Easy to install<br />

• Powered by two independent packs of 3 AA<br />

alkaline batteries with a typical three year life


XPander Loop Interface<br />

The XPander Loop Interface communicates<br />

between the Intelligent control panel and the<br />

XPander detectors as the detectors alone can’t<br />

communicate directly with the panel.<br />

XPander Interface Unit XPA-IN-14007-APO<br />

XPander Survey Tool<br />

The XPander Survey Tool is used at the site<br />

survey stage to ascertain if a site is suitable for an<br />

XPander installation. A site survey must be carried<br />

out before XPander can be installed.<br />

XPander Survey Tool XPA-TE-14010-APO<br />

Ancillary devices available for the XPander range:<br />

Wireless Technology 11 43<br />

• Tests for radio signal strength<br />

XPANDER<br />

• Connects up to 15 XPander devices to a<br />

XP95 loop<br />

• Translates radio signals from XPander<br />

detectors to the control panel<br />

• Incorporates an integral loop isolator and is<br />

polarity sensitive<br />

There are two aerials available to complement the XPander range:<br />

• XPander External Aerial (XPA-AE-14008-APO) which is used to strengthen the radio signals<br />

sent between the XPander Interface Unit and XPander devices.<br />

• XPander External Directional Aerial (XPA-AE-14009-APO) which is used to pick up radio signals<br />

from outbuildings and annexes.<br />

Product Name Part Number Page No.<br />

XPander Manual Call Point XPA-MC-14006-APO 80<br />

XPander Sounder and Sounder Base Red XPA-CB-14001-APO 54<br />

XPander Sounder and Sounder Base White XPA-CB-14002-APO 54<br />

XPander Red Sounder Beacon and Red Sounder Base XPA-CB-14003-APO 63<br />

XPander Amber Sounder Beacon and White Sounder Base XPA-CB-14004-APO 63<br />

XPander Clear Sounder Beacon and White Sounder Base XPA-CB-14005-APO 63<br />

XPander Blank XPERT Card (White) 29600-413<br />

XPander Blank XPERT Card (Red) 29600-399<br />

XPander XPERT cards are not interchangeable with those used with Discovery and XP95.<br />

XPander Sounder and<br />

Sounder Base Red<br />

XPA-CB-14001-APO<br />

XPander Red Sounder Beacon<br />

and Red Sounder Base<br />

XPA-CB-14003-APO<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

XPander Manual Call Point<br />

XPA-MC-14006-APO


44<br />

Specialist Detectors<br />

Specialist<br />

Detectors<br />

In addition to standard detectors, Apollo offer a<br />

range of specialist detectors suitable for a wide<br />

variety of applications.


Flame detectors are effective in<br />

protecting areas where flaming fires<br />

may be expected.<br />

There is a choice of <strong>detection</strong><br />

techniques - Ultra Violet and Infra-red,<br />

or a combination of both.<br />

UV Flame Detectors are generally<br />

used in engine rooms, factories and<br />

warehouse applications.<br />

Infra-red Flame Detectors are able to<br />

tolerate dirtier environments which<br />

may block UV radiation and are<br />

generally used in applications such as<br />

waste handling, colour printing and<br />

paper manufacturing.<br />

Specialist Detectors 45<br />

FLAME DETECTORS<br />

Flame<br />

Detectors<br />

specialist detectors


46<br />

Specialist Detectors<br />

FLAME DETECTORS<br />

Intelligent Dual IR Flame Detector<br />

The Intelligent Dual Infra-Red (IR²) Flame Detector<br />

is designed for use in areas where flaming fires<br />

may be expected. The detector has two sensors<br />

which respond to different IR wavelengths to<br />

discriminate between flames and spurious sources<br />

of radiation. Applications include aircraft hangars,<br />

coal handling and paper manufacturing plants and<br />

woodworking environments.<br />

Intelligent IR² Flame Detector 55000-280<br />

Intelligent Flameproof IR²<br />

Flame Detector<br />

55000-295<br />

Intelligent Triple IR Flame Detector<br />

The Intelligent Triple IR Flame Detector (IR³) is<br />

designed to protect areas where open flaming<br />

fires may be expected. It is sensitive to lowfrequency,<br />

flickering infra-red radiation emitted by<br />

flames during combustion.<br />

Intelligent IR³ Flame Detector 55000-020<br />

Intelligent Flameproof IR³ Flame<br />

Detector<br />

55000-021<br />

Flame Detector Bracket<br />

The Flame Detector Bracket is an optional accessory<br />

for the Intelligent Flame Detectors. It is a stainless<br />

steel mounting bracket adjustable in two axis. Not<br />

suitable for Base Mounted Flame Detectors<br />

Flame Detector Bracket 29600-203<br />

Flame Detector Weather Shield<br />

The Flame Detector Weather Shield protects the<br />

device from inclement conditions.<br />

Flame Detector Weather Shield 29600-206<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

• Sensitive to flickering IR radiation<br />

• Detects through films of oil, dust, water<br />

and ice<br />

• Responds to flickering flames, including<br />

those invisible to the naked eye<br />

• Compatible with Discovery and XP95 protocols<br />

• Remote optical self-test function<br />

• 90° field of view<br />

• Up to 40m coverage<br />

• Loop-powered<br />

• Sensitive to flickering IR radiation<br />

• Detects through films of oil, dust, water<br />

and ice<br />

• Responds to flickering flames, including those<br />

invisible to the naked eye<br />

• False alarms due to lighting or flickering<br />

sunlight are minimised<br />

• Compatible with Discovery and XP95 protocols<br />

• Allows flame detector to be moved to desired<br />

position<br />

• Protects against water ingress<br />

• Protects sensor from direct sunlight


Intelligent Base Mounted UV Flame<br />

Detector<br />

The Intelligent Base Mounted UV Flame Detector<br />

is designed to protect internal areas where open<br />

fires may be expected. The detector has a single<br />

UV sensor with a narrow spectral response in<br />

order to discriminate between flames and most<br />

spurious sources of radiation.<br />

Intelligent Base Mounted UV Flame 55000-022<br />

Detector<br />

Base Mounted Flame Detector Bracket 29600-458<br />

Intelligent Base Mounted UV IR²<br />

Flame Detector<br />

The Intelligent Base Mounted UV IR² Flame<br />

Detector is designed to protect areas where open<br />

flaming fires may be expected. The detector has<br />

a UV and dual IR sensors responding to different<br />

wavelengths in order to discriminate between<br />

flames and spurious sources of radiation.<br />

Intelligent Base Mounted UV IR² 55000-023<br />

Flame Detector<br />

Base Mounted Flame Detector Bracket 29600-458<br />

Intelligent Base Mounted IR³ Flame<br />

Detector<br />

The Intelligent Base Mounted IR³ Flame Detector<br />

is designed to protect areas where open flaming<br />

fires may be expected. The detector has three IR<br />

sensors that respond to different IR wavelengths<br />

in order to discriminate between flames and<br />

spurious sources of radiation.<br />

Intelligent Base Mounted IR³ 55000-024<br />

Flame Detector<br />

Base Mounted Flame Detector Bracket 29600-458<br />

Ancillary products:<br />

Specialist Detectors 47<br />

FLAME DETECTORS<br />

• Responds to stationary flames with no flicker<br />

• Sensitive to UV radiation emitted by flames<br />

during combustion<br />

• Compact flame detector which can fit into<br />

Discovery or XP95 bases<br />

• Loop-powered<br />

• Responds to stationary flames with no flicker<br />

• Sensitive to UV and low-frequency flickering IR<br />

radiation emitted by flames during combustion<br />

• Compact flame detector which can fit into<br />

Discovery or XP95 bases<br />

• Loop-powered<br />

• False alarms due to electrical discharges from<br />

lightning or arc welding and flickering sunlight<br />

are minimised<br />

• Responds to stationary flames with no flicker<br />

• Sensitive to low-frequency flickering<br />

IR radiation emitted by flames during<br />

combustion.<br />

• Compact flame detector which can fit into<br />

Discovery or XP95 bases<br />

• Loop-powered<br />

• False alarms due to factors such as flickering<br />

sunlight are avoided by a combination of filters<br />

and signal processing techniques.<br />

Product Name Part Number Page No.<br />

Flame Sensor Test Unit and Case 29600-226 117<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.


48<br />

Specialist Detectors<br />

BEAM DETECTORS<br />

Beam<br />

Detectors<br />

specialist detectors<br />

Beam detectors are designed to<br />

protect large open spaces such as atria,<br />

museums, churches and warehouses.


Optical Beam Detector<br />

The conventional beam detector is made up of<br />

three parts: the transmitter, which projects a beam<br />

of infra-red light, the receiver, which registers<br />

the light and produces an electric signal, and the<br />

interface, which processes the signal and generates<br />

alarm or fault signals.<br />

Optical Beam Detector 29600-242<br />

Intelligent Reflective Beam Detector<br />

The Intelligent Reflective Beam Detector differs<br />

from a traditional beam detector in that it is a single<br />

unit which houses a transmitter, a receiver and the<br />

control electronics. The beam detector is available in<br />

two versions: a single reflector model for distances<br />

of 5-50m and a four-reflector unit for distances of<br />

50-100m.<br />

Intelligent Reflective Beam 55000-268<br />

Detector 5-50m<br />

Intelligent Reflective Beam 55000-273<br />

Detector 50-100m<br />

Reflective Beam Detector Backbox<br />

The Reflective Beam Detector Backbox allows easy<br />

first fixing of the cabling and terminations to the<br />

Intelligent Reflective Beam Detector (55000-268 &<br />

58000-273). The backbox can be surface or flush<br />

mounted.<br />

Reflective Beam Detector Backbox 29600-241<br />

<strong>Fire</strong>beam ®<br />

<strong>Fire</strong>beam is a reflective beam smoke detector<br />

which is designed to protect large open spaces. It<br />

incorporates a motorised head that can align itself<br />

during commissioning.<br />

<strong>Fire</strong>beam Reflective Beam<br />

Detector 5-40m<br />

29600-350<br />

<strong>Fire</strong>beam Extension Kit 40-80m 29600-351<br />

<strong>Fire</strong>beam Extension Kit 80-100m 29600-352<br />

<strong>Fire</strong>beam Adaptor Plate 29600-353<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

<strong>Fire</strong>beam ® is a registered trade mark of The <strong>Fire</strong> Beam Company<br />

Specialist Detectors 49<br />

BEAM DETECTORS<br />

• Three selectable sensitivity levels<br />

• Drift compensation<br />

• Remote low interface<br />

• Simple wiring and alignment<br />

• Use XP95 Switch Monitor (55000-843) to<br />

interface it to an addressable loop.<br />

• Loop-powered<br />

• Compatible with Discovery and XP95 protocols<br />

• Incorporates a short-circuit isolator<br />

• Automatic drift compensation<br />

• Automatic reset following alarm or fault<br />

condition<br />

• Aesthetically pleasing<br />

• Continually corrects itself against building<br />

movement<br />

• Controlled and adjusted from ground level


50<br />

Specialist Detectors<br />

DUCT DETECTORS<br />

Duct<br />

Detectors<br />

specialist detectors


Intelligent Duct Smoke Detector<br />

The Intelligent Duct Smoke Detector provides early<br />

<strong>detection</strong> of smoke in the air moving through<br />

heating and ventilation (HVAC) ducts in commercial<br />

and industrial premises. Its purpose is to prevent the<br />

re-circulation of smoke from an area on fire to areas<br />

unaffected by the fire.<br />

Intelligent Duct Smoke Detector 53546-022<br />

Conventional Duct Smoke Detector<br />

The Conventional Duct Smoke Detector provides<br />

early <strong>detection</strong> of smoke in the air moving through<br />

heating and ventilation (HVAC) ducts in commercial<br />

and industrial premises. Its purpose is to prevent the<br />

re-circulation of smoke from an area on fire to areas<br />

unaffected by the fire.<br />

Conventional Duct Smoke Detector 53546-021<br />

Orbis Duct Detector<br />

The Orbis Duct Detector provides early <strong>detection</strong><br />

of smoke in the air moving through heating and<br />

ventilation (HVAC) ducts.<br />

Orbis Duct Detector 53546-023<br />

Extension Tubes<br />

Specialist Detectors 51<br />

DUCT DETECTORS<br />

• Operates in air speeds of 0.5m/s to 20m/s<br />

• Transparent cover to view detector head LED<br />

• Integral smoke test port<br />

• For S65 and S60 ranges<br />

• Operates in air speeds of 0.5m/s to 20m/s<br />

• Transparent cover to view detector head LED<br />

• Integral smoke test port<br />

• Designed to accept an Orbis detector head<br />

• Used as supplementary <strong>detection</strong><br />

Product Name Part Number<br />

300-750mm 53541-170<br />

750-1500mm 53541-171<br />

1500-3000mm 53541-172<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.


10 52<br />

Audio Visual Signalling<br />

Audio<br />

Visual<br />

Signalling<br />

Apollo offer a wide range of Audio Visual (AV)<br />

signalling devices – sounders, beacons, sounder<br />

beacons and sounder beacon bases for use in<br />

conjunction with their range of conventional and<br />

intelligent detectors to meet the requirements of<br />

the DDA.


Audio Visual Signalling 53<br />

SOUNDERS<br />

Sounders<br />

audio visual signalling


54<br />

Audio Visual Signalling<br />

SOUNDERS<br />

Intelligent Open-Area Sounder<br />

The Intelligent Open-Area Sounder has been<br />

designed for use in open areas and can be<br />

connected to any Discovery or XP95 system.<br />

Intelligent Open-Area Sounder 55000-001<br />

Red<br />

Intelligent Open-Area Sounder 55000-002<br />

White<br />

Intelligent 100dB(A) Open-Area<br />

Sounder<br />

The 100dB(A) Loop-Powered Sounder is designed<br />

for use in open areas and can be connected to any<br />

Discovery or XP95 system.<br />

Intelligent 100dB(A) Open-Area 55000-278<br />

Sounder Red<br />

Intelligent 100dB(A) Open-Area 55000-279<br />

Sounder White<br />

Intelligent 100dB(A) Open-Area 55000-276<br />

Sounder Slow Whoop Red<br />

Intelligent 100dB(A) Open-Area 55000-277<br />

Sounder Slow Whoop White<br />

Intelligent Weatherproof 100dB(A)<br />

Open-Area Sounder<br />

The 100dB(A) Weatherproof Sounder is designed<br />

for use in open areas and can be connected to any<br />

Discovery or XP95 system. The sounder comprises<br />

a backbox and sounder unit supplied together.<br />

100dB(A) Weatherproof Sounder 55000-274<br />

Red<br />

100dB(A) Weatherproof Sounder 55000-275<br />

White<br />

XPander Sounder and<br />

Sounder Base<br />

The XPander Sounder and Sounder Base is<br />

wireless and designed to be used with XPander<br />

detectors and manual call points only.<br />

XPander Sounder and XPA-CB-14001-APO<br />

Sounder Base Red<br />

XPander Sounder and XPA-CB-14002-APO<br />

Sounder Base White<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

• Self-test fault monitoring<br />

• Choice of tones<br />

• Group addressing and synchronisation of alarm<br />

• Weatherproof IP65<br />

• Comes with Isolating Base as standard<br />

• Loop powered<br />

• Output is 100 dB(A) at 90º<br />

• Ceiling Mounted<br />

• Output is 100dB(A) at 90°<br />

• Current consumption of 5.0mA<br />

• Can be synchronised<br />

• Group address facility<br />

• Loop powered<br />

• Wall mounted<br />

• IP 66 (immune to the affects of wind and<br />

precipitation)<br />

• Output is 100dB(A) at 90°<br />

• Current consumption of 5.0mA<br />

• Can be synchronised<br />

• Group address facility<br />

• Loop powered<br />

• Wall mounted<br />

• Wall mounted<br />

• Wireless<br />

• Eliminates cable problems<br />

• Output is between 92 and 106db(A) at 1m -<br />

dependent on tone setting


Audio Visual Signalling 55<br />

BASE SOUNDERS<br />

Base<br />

Sounders<br />

audio visual signalling


56<br />

Audio Visual Signalling<br />

BASE SOUNDERS<br />

Integrated Base Sounder<br />

The Integrated Base Sounder comprises a base<br />

sounder with integral mounting base and is for<br />

use with Discovery or XP95 ranges. It is designed<br />

for use in enclosed areas.<br />

Integrated Base Sounder † 45681-278<br />

Integrated Base Sounder<br />

with Isolator †<br />

45681-277<br />

Integrated Base Sounder<br />

Slow Whoop †<br />

45681-291<br />

Integrated Base Sounder<br />

Slow Whoop with Isolator †<br />

45681-290<br />

Integrated Base Sounder<br />

DIN-Tone with Isolator<br />

45681-300<br />

Red Cap* 45681-293<br />

White Cap* 45681-292<br />

Intelligent Base Sounder<br />

The Intelligent Base Sounder is for use with<br />

Discovery or XP95 ranges. It is a loop-powered<br />

sounder used to signal a fire alarm in enclosed<br />

areas. A Discovery or XP95 Mounting Base must<br />

be fitted to the Base Sounder, if a detector is to be<br />

fitted.<br />

Intelligent Base Sounder 45681-265<br />

Intelligent Base Sounder, for use<br />

with Isolating Base<br />

45681-266<br />

Intelligent Base Sounder<br />

Slow Whoop<br />

45681-267<br />

Intelligent Base Sounder Slow<br />

Whoop, for use with Isolating Base<br />

45681-268<br />

Red Cap* 29600-257<br />

White Cap* 29600-256<br />

Ancillary Base Sounder<br />

The Ancillary Base Sounder is a local-area sounder<br />

designed for indoor use. It can be connected only<br />

to <strong>detection</strong> systems using Discovery or XP95<br />

detectors and control panels with appropriate<br />

software.<br />

Ancillary Base Sounder 45681-276<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

† Does not have VdS approval<br />

* Does not have CPD or VdS approval<br />

• Two tone ranges<br />

• Synchronisation of ‘alert’ and ‘evacuate’ tones<br />

• Individual and group addressing<br />

• Unique acoustic self-test<br />

• Integrated base<br />

• Isolator option<br />

• Synchronisation of continuous and pulsed<br />

tones<br />

• Multiple address allocation via master/slave<br />

configuration<br />

• Loop powered<br />

• Choice of two output levels<br />

• Guaranteed sound output of 85dB(A) at 1<br />

metre<br />

• Current consumption of only 3mA<br />

• Loop powered<br />

• Responds to signals from the associated<br />

detector - does not have an address of its own<br />

• Adjustable volume control


Series 65 Sounder Base<br />

The Series 65 Sounder Base is a high-efficiency<br />

conventional alarm sounder incorporating a base<br />

for the Series 65 range of detectors. It is designed<br />

so that separate detector and sounder circuits can<br />

be connected. The sounder base can be secured<br />

to a conduit box or surface mounted.<br />

Series 65 Sounder Base 45681-512<br />

Series 65 Sounder Base with diode 45681-513<br />

AlarmSense Sounder Base<br />

The AlarmSense Sounder Base can only be<br />

used with AlarmSense detectors. It is fitted with<br />

electronic circuitry to monitor the presence of<br />

detectors and signals any unauthorised removal<br />

of detector heads. It is supplied with a high or low<br />

volume setting and red or white caps are available<br />

for stand-alone installation<br />

AlarmSense Sounder Base LR 45681-341<br />

AlarmSense Sounder Base 45681-510<br />

Red Cap 45681-295<br />

White Cap 45681-294<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

Audio Visual Signalling 57<br />

BASE SOUNDERS<br />

• 32 tones as standard<br />

• Provides <strong>detection</strong> and alarm signal at one<br />

point<br />

• Diode option<br />

• Detects the removal of a detector head and<br />

reports a fault<br />

• Continues to work during unauthorised<br />

removal of detectors<br />

• Quick and simple installation<br />

• Provides audible signal and <strong>detection</strong> at<br />

one point<br />

• High and low volume ranges


58<br />

Audio Visual Signalling<br />

BEACONS<br />

Beacons<br />

audio visual signalling


Intelligent Open-Area Beacon<br />

The Intelligent Open-Area Beacon has been<br />

developed for use in situations where there is a risk<br />

that sounders will not be heard. It is weatherproof<br />

and can be used outside.<br />

Intelligent Open-Area Beacon 55000-009<br />

Red Lens<br />

Intelligent Open-Area Beacon 55000-010<br />

Clear Lens<br />

Loop-Powered Beacon<br />

The Loop-Powered Beacon is a local-area beacon<br />

designed for indoor use. The beacon has been<br />

developed as a supplement to sounders for use in<br />

situations where there is a risk that sounders will<br />

not be heard.<br />

Loop-Powered Beacon Red 55000-877<br />

Loop Powered Beacon Amber<br />

Loop Powered Beacon<br />

55000-879<br />

Clear Lens/Red Flash 55000-878<br />

Beacon Enclosure<br />

The Beacon Enclosure is weatherproof and allows<br />

Apollo’s loop-powered beacon to be used in highmoisture<br />

environments such as swimming pools<br />

and food processing areas where wash-down<br />

occurs. The enclosure is supplied with a mounting<br />

bracket to accept a Discovery or XP95 base.<br />

Beacon Enclosure 29600-318<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

Audio Visual Signalling 59<br />

• Self-test fault monitoring<br />

• Weatherproof IP65<br />

• Group addressing<br />

• Synchronisation of alarm<br />

• Comes with Isolating Base as standard<br />

• Loop powered<br />

• High intensity LEDs<br />

• More reliable than xenon beacons<br />

• Automatic LED check<br />

• Lockable<br />

• Wide angle of visibility<br />

• Enables DDA compliance<br />

• Synchronised flash<br />

• Can be used with Discovery or XP95<br />

• Protects against water ingress<br />

• Allows beacon to be used outdoors<br />

• Accepts MiniDisc Remote Indicator<br />

• IP67<br />

BEACONS


60<br />

Audio Visual Signalling<br />

BEACON BASES<br />

Beacon<br />

Bases<br />

audio visual signalling


Loop-Powered Beacon Base<br />

The Beacon Base is a loop-powered beacon<br />

combined with a standard Intelligent Mounting<br />

Base. It is used to signal a fire alarm in enclosed<br />

areas. The beacon base can be used with either a<br />

detector fitted or with a cap as a stand-alone alarm<br />

device.<br />

Loop-Powered Beacon Base<br />

with Isolator<br />

45681-333<br />

Loop-Powered Beacon Base<br />

with Standard Flash<br />

45681-335<br />

Loop-Powered Beacon Base<br />

with Australian Flash<br />

45681-337<br />

White Cap 45681-292<br />

Red Cap 45681-293<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

Audio Visual Signalling 61<br />

BEACON BASES<br />

• Beacon flash rate of once per second<br />

• Synchronisation of beacon flash<br />

• Individual and group addressing<br />

• Unique beacon self-test<br />

• Loop powered<br />

• Isolator option


62<br />

Audio Visual Signalling<br />

SOUNDER BEACONS<br />

Sounder<br />

Beacons<br />

audio visual signalling


Intelligent Open-Area Sounder Beacon<br />

The Intelligent Open-Area Sounder Beacon<br />

is designed for use in open areas and can be<br />

connected to an Apollo intelligent system.<br />

Intelligent Open-Area Sounder 55000-005<br />

Beacon Red Lens<br />

Intelligent Open-Area Sounder 55000-006<br />

Beacon Clear Lens<br />

Multi-Tone Open-Area Sounder Beacon<br />

The Multi-Tone Open-Area Sounder Beacon is<br />

designed for use in indoor open areas and can be<br />

connected to any Discovery or XP95 system. The<br />

sounder beacon complements Apollo’s intelligent<br />

and integrated base sounders as well as the loop<br />

powered 100dB(A) sounder.<br />

Multi-Tone Open Area Sounder 55000-293<br />

Beacon Red with Isolator †<br />

Multi-Tone Open Area Sounder 55000-294<br />

Beacon White with Isolator †<br />

Multi-Tone Open Area Sounder 55000-291<br />

Beacon Red<br />

Multi-Tone Open Area Sounder 55000-292<br />

Beacon White †<br />

Weatherproof Multi-Tone Open Area<br />

Sounder Beacon<br />

The Weatherproof Multi-Tone Open Area Sounder<br />

Beacon is designed for use in outdoor open<br />

areas and can be connected to any Discovery or<br />

XP95 system. The sounder beacon complements<br />

Apollo’s intelligent and integrated base sounders<br />

as well as the loop powered 100dB(A) sounder.<br />

Weatherproof Multi-Tone Open Area 55000-298<br />

Sounder Beacon Red with Isolator<br />

Weatherproof Multi-Tone Open Area 55000-299<br />

Sounder Beacon White with Isolator<br />

Weatherproof Multi-Tone Open Area 55000-296<br />

Sounder Beacon Red<br />

Weatherproof Multi-Tone Open Area 55000-297<br />

Sounder Beacon White<br />

XPander Sounder Beacon and<br />

Sounder Base<br />

The XPander Sounder Beacon and Sounder Base<br />

is wireless and designed to be used with XPander<br />

detectors and manual call points only.<br />

XPander Red Sounder XPA-CB-14003-APO<br />

Beacon and Red Sounder Base<br />

XPander Amber Sounder XPA-CB-14004-APO<br />

Beacon and White Sounder Base<br />

XPander Clear Sounder XPA-CB-14005-APO<br />

Beacon and White Sounder Base<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

† Does not have CPD approval<br />

Audio Visual Signalling 63<br />

SOUNDER BEACONS<br />

• IP65 weatherproof<br />

• Gives two functions at one point<br />

• Self-test fault monitoring<br />

• Choice of tones<br />

• Group addressing and synchronisation of alarm<br />

• Comes with Isolating Base as standard<br />

• Loop powered<br />

• Powerful LED combined with 100dB(A) sound<br />

output<br />

• Two volume settings<br />

• Synchronisation of ‘alert’ and ‘evacuate’ tones<br />

• Individual and group addressing<br />

• Three tone choices<br />

• Enables DDA compliance<br />

• Isolator option<br />

• IP66 (immune to the affects of wind and<br />

precipitation)<br />

• Powerful LEDs combined with 100dB(A) sound<br />

output<br />

• Two volume settings<br />

• Synchronisation of ‘alert’ and ‘evacuate’ tones<br />

• Individual and group addressing<br />

• Three tone choices<br />

• Enables DDA compliance<br />

• Isolator option<br />

• Wireless<br />

• Eliminates cable problems<br />

• Enables DDA compliance


64<br />

Audio Visual Signalling<br />

SOUNDER BEACON BASES<br />

Sounder<br />

Beacon<br />

Bases<br />

audio visual signalling


Sounder Beacon Base<br />

The Sounder Beacon Base is a loop-powered<br />

sounder and beacon combined with a standard<br />

Intelligent Mounting Base. It is used to signal a<br />

fire alarm in enclosed areas. The Sounder Beacon<br />

Base can be used either with a detector fitted or<br />

with a cap for operation as a stand-alone alarm<br />

device.<br />

Sounder Beacon Base with Isolator † 45681-330<br />

Sounder Beacon Base † 45681-331<br />

Sounder Beacon Base 45681-336<br />

with Australian Tone †<br />

Sounder Beacon Base with NZ Tone † 45681-338<br />

Sounder Beacon Base Slow Whoop 45681-332<br />

with Isolator †<br />

Sounder Beacon Base 45681-334<br />

with Isolator DIN-Tone<br />

White Cap †‡ 45681-292<br />

Red Cap †‡ 45681-293<br />

AlarmSense Sounder Beacon Base<br />

The AlarmSense Sounder Beacon Base is designed<br />

to be used with AlarmSense detectors only.<br />

AlarmSense Sounder Beacon Base LR 45681-340<br />

AlarmSense Sounder Beacon Base 45681-509<br />

Red Cap 45681-295<br />

White Cap 45681-294<br />

Discovery Sounder<br />

Beacon Base<br />

The Discovery Sounder Beacon Base makes<br />

full use of the Discovery protocol. For ease of<br />

commissioning a ‘magnetic wand’ can be used to<br />

test and adjust each sounder locally.<br />

Discovery Sounder Beacon Base 45681-393<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

† Does not have VdS approval<br />

‡ Does not have CPD approval<br />

Audio Visual Signalling 65<br />

SOUNDER BEACON BASES<br />

• Two volume ranges 55-75dB(A) and<br />

75-91dB(A)<br />

• Beacon flash rate of once per second<br />

• Synchronisation of ‘alert’ and ‘evacuate’ tones<br />

• Synchronisation of beacon flash<br />

• Individual and group addressing<br />

• Unique acoustic and beacon self test<br />

• Enables DDA compliance<br />

• Sounder range between 70dB(A) and 87dB(A)<br />

• Detects the removal of a detector head and<br />

reports a fault<br />

• Continues to work during unauthorised<br />

removal of detectors<br />

• Quick and simple installation<br />

• It is possible to set individual control of the<br />

sounder and beacon<br />

• Volume and tone settings can be selected<br />

from the control panel<br />

• Tones can be used for other purposes in<br />

addition to warning of fire, ideal for schools<br />

• Enables soft start option, ideal for hospitals<br />

and nursing homes<br />

• Electronic bell tone


66<br />

Audio Visual Signalling<br />

AV ACCESSORIES<br />

Audio<br />

Visual<br />

Accessories<br />

audio visual signalling


Beacon Enclosure<br />

The Beacon Enclosure is weatherproof allowing<br />

a loop-powered beacon to be installed outside<br />

and in high moisture environments such as<br />

swimming pools.<br />

Beacon Enclosure 29600-318<br />

Magnetic Wand<br />

The Magnetic Wand is used to initiate and terminate<br />

actions such as adjusting and setting the sound<br />

levels of the Discovery Sounder Beacon Base.<br />

Magnetic Wand 29650-001<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

Audio Visual Signalling 67<br />

• Can be installed outside<br />

• IP 67<br />

AV ACCESSORIES<br />

• Flexibility to set sound output to desired level<br />

during walk test<br />

• Allows local testing of Discovery Sounder<br />

Beacon Bases<br />

• 1.2m when extended


68<br />

Interfaces<br />

Interfaces<br />

Apollo manufactures a comprehensive range of<br />

interfaces for intelligent systems which enable fire<br />

protection systems to be engineered simply and<br />

effectively without the need for custom-designed<br />

<strong>equipment</strong>. There are a variety of interfaces<br />

available to suit a number of individual applications.


Standard Interfaces are fitted with<br />

bi-directional short-circuit isolators so<br />

that they are unaffected by a single<br />

short circuit on either loop input or<br />

output. The exception to this is the<br />

Mains Input/Output unit which is not<br />

isolated.<br />

Key features of Apollo Interfaces:<br />

• Easy to install<br />

• Well protected<br />

• Modular design<br />

• A neat solution<br />

Interfaces 69<br />

STANDARD INTERFACES<br />

Standard<br />

Interfaces


70<br />

Interfaces<br />

STANDARD INTERFACES<br />

Input/Output Unit<br />

The Input/Output unit provides a voltage<br />

free, double pole change-over (DPCO) relay<br />

output, a single monitored switch input and an<br />

unmonitored, non-polarised opto-coupled input.<br />

Input/Output Unit 55000-847<br />

Three Channel Input/Output Unit<br />

The Three Channel Input/Output Unit provides<br />

three voltage-free, single pole, change-over relay<br />

outputs and three monitored switch inputs.<br />

Three Channel Input/Output Unit 55000-588<br />

Output Unit<br />

The Output Unit provides a voltage-free single<br />

pole, change-over relay output. It is a simplified<br />

version of the Input/Output unit without circuitry<br />

for monitoring inputs.<br />

Output Unit 55000-849<br />

Sounder Control Unit<br />

The Sounder Control Unit is used to control the<br />

operation of a zone of conventional sounders and<br />

report their status to the control panel.<br />

Sounder Control Unit 55000-852<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

• It can report fault, switch open and switch<br />

closed levels<br />

• Three visible LEDs<br />

• Loop powered<br />

• Voltage free<br />

• Capable of switching up to 30V at 1A<br />

• Supervises one or more normally-open<br />

switches on each of the three inputs<br />

• Loop powered<br />

• Capable of switching up to 30V at 1A on each<br />

of the three outputs<br />

• Capable of switching up to 30V at 1A<br />

• Allows sounders to be operated continuously<br />

or be pulsed, 1 second on, 1 second off<br />

• May be synchronised when in pulsed operation


Switch Monitor<br />

The Switch Monitor is designed to monitor the<br />

state of one or more single pole, volt free contacts<br />

connected on a single pair of cables and to report<br />

the status to Apollo compatible analogue control<br />

<strong>equipment</strong>.<br />

Switch Monitor 55000-843<br />

Switch Monitor Plus<br />

The Switch Monitor Plus is designed to monitor<br />

the state of one or more single pole, volt free<br />

contacts connected on a single pair of cables and<br />

to report the status to Apollo compatible analogue<br />

control <strong>equipment</strong>.<br />

Switch Monitor Plus 55000-841<br />

Zone Monitor<br />

The Zone Monitor powers and controls the<br />

operation of a zone of up to 20 Apollo Series 65<br />

or Orbis fire detectors from a Discovery or XP95<br />

Loop.<br />

Zone Monitor 55000-845<br />

Mains Switching Input/Output Unit*<br />

The Mains Switching Input/Output Unit provides a<br />

voltage-free, single pole change-over relay output<br />

and a monitored switch input.<br />

Mains Switching Input/Output Unit 55000-875<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

*Not isolated<br />

Interfaces 71<br />

STANDARD INTERFACES<br />

• Four input states - ’normal’, ’fault’,<br />

’pre-alarm’ and ’alarm’<br />

• Two visible LEDs<br />

• Loop powered<br />

• Output for resetting a remote detector<br />

• Four input states - ’normal’, ’fault’,<br />

’pre-alarm’ and ’alarm’<br />

• Two visible LEDs<br />

• Selectable alarm delay for monitoring<br />

flow switches<br />

• Loop powered<br />

• Visible LED<br />

• Supervises one or more normally-open<br />

switches connected to a single pair of cables<br />

• Three visible LEDs<br />

• Capable of switching 250V AC at up to 5A


72<br />

Interfaces<br />

STANDARD INTERFACES<br />

With the exception of the Mains Switching Input/Output Unit Apollo’s range of standard interfaces<br />

without Isolators has been discontinued. The alternatives are listed below.<br />

Comparison chart<br />

Product Name Part Number<br />

Without Isolator With Isolator<br />

Input/Output Unit 55000-818 55000-847<br />

Three Channel Input/Output Unit 55000-589 55000-588<br />

Output Unit 55000-819 55000-849<br />

Sounder Control Unit 55000-823 55000-852<br />

Switch Monitor 55000-810 55000-843<br />

Switch Monitor Plus 55000-809 55000-841<br />

Zone Monitor 55000-813 55000-845<br />

Mains Switching I/O Unit 55000-875 N/A<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.


Mini Interfaces use very compact<br />

enclosures for installation into other<br />

<strong>equipment</strong>.<br />

Interfaces 73<br />

MINI INTERFACES<br />

Mini<br />

Interfaces


74<br />

Interfaces<br />

MINI INTERFACES<br />

Mini Switch Monitor<br />

The New Mini Switch Monitor is an interface<br />

within an entirely new housing. This allows the<br />

unit to be fitted onto a standard 35mm DIN-Rail<br />

(using a twist-click motion) or mounted within<br />

an enclosure, for example a manual call point. It is<br />

designed to monitor the state of one or more single<br />

pole, volt free contacts connected on a single<br />

pair of cables and to report the status to Apollo<br />

compatible analogue control <strong>equipment</strong>.<br />

Mini Switch Monitor 55000-760<br />

Mini Switch Monitor with fly leads<br />

The Mini Switch Monitor is designed to monitor<br />

the state of one or more single pole, volt free<br />

contacts connected on a single pair<br />

of cables and to report the status to Apollo<br />

compatible analogue control <strong>equipment</strong>.<br />

Mini Switch Monitor 55000-833<br />

Mini Switch Monitor with fly leads<br />

(Interrupt)<br />

The Mini Switch Monitor (Interrupt) is designed to<br />

monitor the state of one or more single pole, volt<br />

free contacts connected on a single pair of cables<br />

and to report the status to Apollo compatible<br />

analogue control <strong>equipment</strong>. It can also place<br />

a current pulse in the ‘interrupt’ bit to signal the<br />

operation of a manual call point.<br />

Mini Switch Monitor (Interrupt) 55000-832<br />

*Please check the Apollo website for up-to-date approvals information.<br />

• Designed for use where space is limited<br />

• Isolated as standard<br />

• Interrupt/non interrupt in one unit<br />

• ‘Pre-alarm’ status available<br />

• Three, coloured LEDs, giving clear status<br />

indication<br />

• Four input states - ’normal’, ’fault’,<br />

’pre-alarm’ and ’alarm’<br />

• Visible LED with remote LED connection option<br />

• Loop powered<br />

• Designed for use where space is limited<br />

• Easy to install<br />

• Three input states - ’normal’, ’fault’ and ’alarm’<br />

• Visible LED with remote LED connection option<br />

• Loop powered<br />

• Designed for use where space is limited<br />

• Easy to install<br />

• Monitors <strong>equipment</strong> where a fast response<br />

is required<br />

• Interrupt facility


Interfaces 75<br />

DIN-RAIL INTERFACES<br />

DIN-Rail Interfaces feature enclosures<br />

that clip to standard 35mm DIN-Rails<br />

or are screwed to the base of a larger<br />

enclosure. They enable fire system<br />

designers to determine the functions<br />

required and create multi-purpose<br />

DIN-Rail<br />

interfaces for individual sites.<br />

Interfaces


76<br />

Interfaces<br />

DIN-RAIL INTERFACES<br />

DIN-Rail Input/Output Unit<br />

The DIN-Rail Input/Output Unit provides a<br />

voltage free, single pole, change-over relay<br />

output, a single, monitored switch input and an<br />

unmonitored, non-polarised opto-coupled input.<br />

DIN-Rail Input/Output Unit 55000-803<br />

DIN-Rail Output Unit<br />

The DIN-Rail Output Unit provides a voltagefree<br />

single pole, change-over relay output. It is a<br />

simplified version of the Input/Output unit without<br />

circuitry for monitoring inputs.<br />

DIN-Rail Output Unit 55000-804<br />

DIN-Rail Switch Monitor<br />

The DIN-Rail Switch Monitor is designed to<br />

monitor the state of one or more single pole, volt<br />

free contacts connected on a single pair of cables<br />

and to report the status to Apollo compatible<br />

analogue control <strong>equipment</strong>.<br />

DIN-Rail Switch Monitor 55000-822<br />

NEW!! DIN-Rail Mains Input/Output Unit<br />

The DIN-Rail Mains Input/Output Unit provides a<br />

voltage-free, single pole change-over relay output<br />

and a monitored switch input. The Unit supervises<br />

one or more normally-open switches connected<br />

to a single pair of cables.<br />

DIN-Rail Mains Input/Output Unit 55000-797<br />

NEW!! DIN-Rail Sounder Controller<br />

(5 Amperes)<br />

The DIN-Rail Sounder Controller (5 Amperes)<br />

is used to control the operation of a zone of<br />

externally powered sounders and report their<br />

status to the control panel.<br />

DIN-Rail Sounder Controller (5 Amp) 55000-182<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

• It can report fault, switch open and switch<br />

closed levels<br />

• Three visible LEDs<br />

• Loop powered<br />

• Voltage free<br />

• Capable of switching up to 30V at 1A<br />

• Capable of switching up to 30V at 1A<br />

• Four input states - ’normal’, ’fault’,<br />

’pre-alarm’ and ’alarm’<br />

• Two visible LEDs<br />

• Loop powered<br />

• It can report fault, switch open and switch<br />

closed levels<br />

• Three visible LEDs<br />

• Capable of switching up to 8A at 240V AC<br />

• Fits a standard 35mm DIN-Rail<br />

• Allows sounders to be operated continuously<br />

or be pulsed, 1 second on, 1 second off<br />

• May be synchronised when in pulsed<br />

operation<br />

• An opto-coupled input is provided to monitor<br />

the state of the external power supply.<br />

• Sounders can be operated individually or in<br />

groups<br />

• Will accept a load of 5 amperes


DIN-Rail Switch Monitor Plus<br />

The DIN-Rail Switch Monitor Plus is designed to<br />

monitor the state of one or more single pole, volt<br />

free contacts connected on a single pair of cables<br />

and to report the status to Apollo compatible<br />

analogue control <strong>equipment</strong>.<br />

DIN-Rail Switch Monitor Plus 55000-821<br />

DIN-Rail Zone Monitor<br />

with Isolator<br />

The Zone Monitor powers and controls the<br />

operation of a zone of up to 20 Apollo Series 65 or<br />

Orbis fire detectors from a Discovery or XP95 Loop.<br />

DIN-Rail Zone Monitor with Isolator 55000-812<br />

DIN-Rail Dual Isolator<br />

The DIN-Rail Dual Isolator provides two<br />

independent Isolators which sense and isolate<br />

short circuits on Discovery or XP95 loops<br />

and spurs.<br />

DIN-Rail Dual Isolator 55000-802<br />

Mini Switch Monitor<br />

The Mini Switch Monitor is an interface within<br />

an entirely new housing. This allows the unit to<br />

be fitted onto a standard 35mm DIN-Rail (using<br />

a twist-click motion) or mounted within an<br />

enclosure, for example a manual call point. It is<br />

designed to monitor the state of one or more single<br />

pole, volt free contacts connected on a single<br />

pair of cables and to report the status to Apollo<br />

compatible analogue control <strong>equipment</strong>.<br />

Mini Switch Monitor 55000-760<br />

DIN-Rail Accessories:<br />

Interfaces 77<br />

DIN-RAIL INTERFACES<br />

• Output for resetting a remote detector<br />

• Four input states - ’normal’, ’fault’,<br />

’pre-alarm’ and ’alarm’<br />

• Two visible LEDs<br />

• Loop powered<br />

• Selectable alarm delay for monitoring<br />

flow switches<br />

• Loop powered<br />

• Visible short circuit LED<br />

• Built in Isolator<br />

• Loop powered<br />

• Polarity sensitive<br />

• Up to 20 detectors can be installed between<br />

isolators<br />

• Allows fully isolated spurs<br />

• Designed for use where space is limited<br />

• Isolated as standard<br />

• Interrupt/non interrupt in one unit<br />

• ‘Pre-alarm’ status available<br />

• Three, coloured LEDs, giving clear status<br />

indication<br />

Product Name Part Number Page No.<br />

DIN-Rail Interface Enclosure (4 units) 29600-239 85<br />

DIN-Rail Interface Enclosure (10 units) 29600-240 85<br />

DIN-Rail End Stops 27447-528<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.


78<br />

Manual Call Points<br />

Manual<br />

Call Points


Discovery Manual Call Point<br />

The Discovery Manual Call Point is compliant<br />

with EN54-11. The Call Point can be addressed<br />

at the commissioning stage by means of a<br />

seven-segment DIL switch. When operated, the<br />

manual call point interrupts the polling cycle for<br />

a fast response.<br />

Discovery Manual Call Point 58100-910<br />

(Surface)<br />

Discovery Manual Call Point 58100-908<br />

with Isolator (Surface)<br />

Discovery Manual Call Point<br />

(non-standard)<br />

In addition to the standard Discovery Manual<br />

Call Point, Apollo offer a selection of differently<br />

coloured call points, suitable for a variety of<br />

different applications.<br />

Discovery Manual Call Point 58100-926<br />

(Non Standard) White (Surface)<br />

Discovery Manual Call Point 58100-927<br />

(Non Standard) Yellow (Surface)<br />

Discovery Manual Call Point 58100-928<br />

(Non Standard) Blue (Surface)<br />

Discovery Manual Call Point 58100-929<br />

(Non Standard) Green (Surface)<br />

XP95 Manual Call Point<br />

The XP95 Manual Call Point is compliant with<br />

EN54-11. The address of each call point is set at the<br />

commissioning stage by means of a seven-segment<br />

DIL switch. The device features plug and play terminal<br />

connections and a resettable element.<br />

XP95 Manual Call Point 55100-905<br />

(Surface)<br />

XP95 Manual Call Point 55100-908<br />

with Isolator (Surface)<br />

Transparent Hinged Cover<br />

The Transparent Hinged Cover is for use with<br />

XP95 and Discovery Manual Call Points and can<br />

be fitted to add further protection against<br />

accidental operation.<br />

Transparent Hinged Cover 26729-152<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

Manual Call Points 79<br />

MANUAL CALL POINTS<br />

• Flashing LED option<br />

• Plug and play terminal connections for<br />

fast wiring<br />

• Allow wiring continuity testing before fitting<br />

• Reports an alarm in under 0.2 seconds<br />

• Resettable element<br />

• Flashing LED option<br />

• Plug and play terminal connections for<br />

fast wiring<br />

• Allow wiring continuity testing before fitting<br />

• Reports an alarm in under 0.2 seconds<br />

• Resettable element<br />

• Plug and play terminal connections for<br />

fast wiring<br />

• Allow wiring continuity testing before fitting<br />

• Reports an alarm in under 0.2 seconds<br />

• Resettable element<br />

• Locking tag<br />

• Reduces risk of vandalism<br />

* Please note - the manual call point does not comply<br />

with EN54 when fitted with this cover.


80<br />

Manual Call Points<br />

MANUAL CALL POINTS<br />

Waterproof Manual Call Point<br />

The Waterproof Manual Call Point has been<br />

designed for use outdoors and in places where<br />

moisture can occur. It is compliant with EN54-11<br />

and can be used with the XP95 and Discovery<br />

ranges.<br />

Waterproof Manual Call Point 58100-950<br />

Waterproof Manual Call Point 58100-951<br />

with Isolator<br />

Waterproof Manual Call Point 58100-953<br />

with Isolator (Yellow)†<br />

AlarmSense Manual Call Point<br />

The AlarmSense Manual Call Point is compliant<br />

with EN54:11. It is different from other<br />

conventional call points in that it can be detected<br />

as an operated call point rather than a detector<br />

that has changed to the alarm state.<br />

AlarmSense Manual Call Point 55100-894<br />

(Surface)<br />

XPander Manual Call Point<br />

The XPander Manual Call Point is compliant with<br />

EN54:11. It is wireless and is powered by two<br />

independent packs of 3 AA alkaline batteries<br />

with a typical three year life.<br />

XPander Manual Call Point XPA-MC-14006-APO<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

† Does not have CPD approval<br />

• Plug and play terminal connections for fast<br />

wiring<br />

• Allow wiring continuity testing before fitting<br />

• Resettable element<br />

• IP 67<br />

• Gives immediate response<br />

• Unique identification signalling<br />

• Resettable element<br />

• Uses patented XPERT addressing<br />

• Resettable element<br />

• Reports an alarm in under one second


Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

Manual Call Points 81<br />

MANUAL CALL POINTS


82<br />

Mounting Accessories<br />

Mounting<br />

Accessories


Backplate<br />

The Backplate provides a high degree of<br />

protection against the ingress of water or dust<br />

into the back of the detector mounted directly<br />

onto a mounting box. When the backplate is used<br />

with an XP95 device, the number tab of the XPERT<br />

card must be snapped off and placed in one of the<br />

knockout slots provided in the backplate.<br />

Backplate 45681-233<br />

Base Cover<br />

Base Covers are available as part of the Series 65<br />

and XP95 ranges.<br />

Series 65 Base Cover 45681-370<br />

XP95 Base Cover 45681-380<br />

Conduit Box<br />

The Conduit Box is a versatile accessory for<br />

surface mounting Apollo bases. The box has<br />

knockouts to accept PG16 or M20 cable glands,<br />

conduit or mini-trunking. Self-tapping screws are<br />

included to fit the detector base to the conduit box.<br />

Conduit Box 45681-204<br />

Sounder Ceiling Plate<br />

The Sounder Ceiling Plate allows surface mounted<br />

cabling to be fitted to a loop powered sounder<br />

base.<br />

Sounder Ceiling Plate 45681-311<br />

Module Base<br />

The Module Base is an accessory which<br />

can be secured to a standard base allowing<br />

customers to fit their own electronics.<br />

Module Base 38531-822<br />

Mounting Accessories 83<br />

• Protects against water ingress<br />

• Improved performance<br />

• Fits Discovery, XP95, Orbis, Series 65 and<br />

AlarmSense bases<br />

• Protects base when detector not in situ<br />

• Aesthetically pleasing<br />

• Easy to install<br />

• Aesthetically pleasing<br />

• Ease of installation<br />

• Ideal for use with concrete ceilings where<br />

drilling is not permissible<br />

• 5mm in depth<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

MOUNTING ACCESSORIES


84<br />

Mounting Accessories<br />

MOUNTING ACCESSORIES<br />

Deckhead Mounting Boxes<br />

The Deckhead Mounting Box gives extra<br />

protection to devices to be fitted in areas where<br />

there is the possibility of moisture or condensation<br />

ingressing through the rear of the of the base.<br />

The new version is suitable for a wider range of<br />

detector bases as well as Apollo’s AV bases.<br />

NEW!! Deckhead Mounting Box 45681-217<br />

Metal Deckhead Mounting Box 29600-131<br />

(has access ports threaded to fit<br />

PG16 glands)<br />

Metal Deckhead Mounting Box 29600-139<br />

(has access ports threaded to fit<br />

M20 components)<br />

Deckhead Adaptor (for use with 27249-005<br />

29600-196 - converts cable glands<br />

from PG16 to M20)<br />

Ceiling Tile Mounting Box<br />

The Ceiling Tile Mounting Box has been designed<br />

to make the installation of detectors and sounders<br />

quick and easy prior to the fitting of a false ceiling.<br />

Detector and sounder bases can be fitted, wired<br />

and, if necessary, tested and commissioned<br />

before the installation of a false ceiling.<br />

Detector Ceiling Tile Mounting Box 45681-309<br />

Sounder Ceiling Tile Mounting Box 45681-310<br />

Beacon Enclosure<br />

The Beacon Enclosure is weatherproof allowing a<br />

loop-powered beacon to be installed outside and<br />

in high moisture environments such as swimming<br />

pools. The enclosure is supplied with a mounting<br />

bracket to accept a Discovery or XP95 base.<br />

Beacon Enclosure 29600-318<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

• Protects against water ingress<br />

• Improved performance<br />

• Available in polycarbonate or metal<br />

• Polycarbonate Deckhead Mounting Box<br />

45681-217 also fits Apollo Audio Visual bases<br />

• No need for separate backbox<br />

• Can be used with tiles up to 25mm thick<br />

• Quick and easy installation<br />

• Protects against water ingress<br />

• Allows beacon to be used outdoors<br />

• Accepts MiniDisc remote indicator<br />

• IP67


DIN-Rail Interface Enclosures<br />

DIN-Rail Interface Enclosures are available in two<br />

sizes and can be used for housing intrinsically safe<br />

(IS) barriers or DIN-rail mounted interfaces. A multipurpose<br />

label that features a section for use with<br />

IS systems is supplied. For non-IS systems, the<br />

part referring to IS can simply be removed.<br />

DIN-Rail Interface Enclosure (4 units) 29600-239<br />

DIN-Rail Interface Enclosure (10 units) 29600-240<br />

1.5mm Hexagonal Driver<br />

The 1.5mm Hexagonal Driver is used to turn the<br />

locking screw fitted to Discovery, XP95 and<br />

Series 65 detectors.<br />

1.5mm Hexagonal Driver 29600-095<br />

Series 90 to XP95 Base Adaptor<br />

The XP95 Base Adaptor is designed to allow XP95<br />

detectors to be fitted to an existing Series 90<br />

base. The adaptor eliminates the need to rewire an<br />

existing Apollo intelligent system.<br />

Series 90 to XP95 Base Adaptor 45681-238<br />

Series 65 to Orbis Base Adaptor<br />

The Orbis Adaptor is designed to allow Orbis<br />

detectors to be fitted to an existing Series 60 or<br />

Series 65 base. The adaptor eliminates the need<br />

to rewire an existing Apollo conventional system.<br />

Series 65 to Orbis Base Adaptor ORB-BA-10008-APO<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

Mounting Accessories 85<br />

MOUNTING ACCESSORIES<br />

• Allows multiple interfaces to be housed<br />

together<br />

• IP67<br />

• Allows detectors to be fitted with ease<br />

• Allows an existing range to be updated<br />

with ease<br />

• Eliminates the need for re-wiring<br />

• Allows an existing range to be updated<br />

with ease<br />

• Eliminates the need for re-wiring


86<br />

Marine<br />

Marine<br />

Apollo offer both conventional and intelligent ranges of<br />

smoke and heat detectors which are approved for use<br />

in the marine environment. These detectors operate in<br />

the same way and carry the same approvals as standard<br />

detectors but are subject to additional approvals tests,<br />

specific to the marine environment.<br />

The marine detectors are approved by the following bodies:<br />

• American Bureau of Shipping<br />

• Bureau Veritas<br />

• China Classification Society<br />

• Det Norske Veritas<br />

• Germanischer Lloyd<br />

• Lloyd’s Register of Shipping<br />

• Maritime and Coastguard Agency<br />

• Marine Marchande Française


Discovery Marine intelligent fire<br />

detectors are suitable for larger<br />

vessels. The high specification range<br />

has been developed to meet the<br />

requirements of sophisticated systems.<br />

Discovery gives you total reassurance<br />

in installations where it is necessary to<br />

adapt <strong>detection</strong> to different operating<br />

environments and where protection<br />

against unwanted alarms is paramount.<br />

Key features of Discovery Marine:<br />

• Approved for use in the marine environment<br />

• Five response modes for environmental adaptation<br />

• Day/Night switching for increased reliability<br />

• Drift compensation for false alarm reduction<br />

• User programmability for data retention<br />

• XPERT card addressing for increased security<br />

Marine 87<br />

DISCOVERY MARINE<br />

Discovery<br />

marine


88<br />

Marine<br />

DISCOVERY MARINE<br />

Discovery Marine<br />

Ionisation Smoke Detector<br />

The Discovery Marine Ionisation Detector uses<br />

a low activity radioactive foil to detect fires by<br />

irradiating the air in the smoke chamber and<br />

causing a current flow. If smoke enters the<br />

chamber, the current flow is reduced leading<br />

to an alarm.<br />

Discovery Marine<br />

Ionisation Smoke Detector 58000-500MAR<br />

Discovery Marine<br />

Optical Smoke Detector<br />

The Discovery Marine Optical Smoke Detector<br />

works using the light scatter principle and is<br />

ideal for applications where slow-burning or<br />

smouldering fires are likely.<br />

Discovery Marine<br />

Optical Smoke Detector 58000-600MAR<br />

Discovery Marine Heat Detector<br />

The Discovery Marine Heat Detector,<br />

distinguishable by the low airflow resistant<br />

case, uses a single thermistor to sense the air<br />

temperature around the detector.<br />

Discovery Marine Heat Detector 58000-400MAR<br />

Discovery Marine Multisensor Detector<br />

The Discovery Marine Multisensor detector<br />

comprises optical smoke and thermistor<br />

temperature sensors whose outputs are combined<br />

to give the final analogue value. As a result,<br />

the multisensor is useful over a wide range of<br />

applications and is highly immune to false alarms.<br />

Discovery Marine<br />

Multisensor Detector 58000-700MAR<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

• Responds well to fast-burning, flaming fires<br />

• Designed to operate in a variety of<br />

environments<br />

• Remote test feature<br />

• Rejection of transient signals<br />

• Responds well to slow-burning, smouldering<br />

fires<br />

• Suitable for bedrooms and escape routes<br />

• Unaffected by wind or atmospheric pressure<br />

• Remote test feature<br />

• Rejection of transient signals<br />

• Ideal in environments that are dirty or smoky<br />

• Unaffected by wind or atmospheric pressure<br />

• Remote test feature<br />

• Rejection of transient signals<br />

• Ideal for a wide range of applications<br />

• Highly immune to false alarms<br />

• Unaffected by wind or atmospheric pressure<br />

• Remote test feature<br />

• Rejection of transient signals


Discovery Marine Mounting Base<br />

All detectors in the Discovery Marine range<br />

are for use with the Marine Mounting Base. The<br />

Mounting Base is a low insertion force base with<br />

stainless steel contacts for the detector terminals.<br />

XPERT cards are supplied with all bases.<br />

Discovery Marine Mounting Base 45681-210MAR<br />

Discovery Marine Manual Call Point<br />

The Discovery Marine Manual Call Point has been<br />

approved for use in indoor marine applications<br />

such as cruise liners. When operated, the manual<br />

call point interrupts the polling cycle for a fast<br />

response.<br />

Discovery Marine Manual 58100-970MAR<br />

Call Point<br />

Discovery Marine Manual 58100-971MAR<br />

Call Point with Isolator<br />

Discovery Marine Isolator<br />

The Discovery Marine Isolator is placed at intervals<br />

on the loop and ensures that, in the case of a short<br />

circuit, only the section between the isolators will<br />

be affected. When the short circuit is removed,<br />

the isolators automatically restore power in the<br />

isolated section.<br />

Discovery Marine Isolator 55000-700MAR<br />

Discovery Marine Isolator Base<br />

The Discovery Marine Isolator Base is unique and<br />

designed to only accept the marine isolator.<br />

Discovery Marine Isolator Base 45681-211MAR<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

Marine 89<br />

DISCOVERY MARINE<br />

• XPERT addressing<br />

• One way fit<br />

• Locking feature to prevent unauthorised<br />

removal<br />

• Reports an alarm in under 0.2 seconds<br />

• Resettable element<br />

• Detects wiring short circuits using patented<br />

technology<br />

• Minimises disruption from short-circuits<br />

• Automatic de-isolation on short-circuit removal<br />

• The equivalent of up to 20 smoke detectors<br />

may be installed between isolators<br />

• Only accepts the Marine Isolator


90<br />

Marine<br />

ORBIS MARINE<br />

Orbis<br />

marine<br />

Orbis Marine conventional fire detectors<br />

offer a wealth of features to save time,<br />

enhance reliability and reduce false<br />

alarms within the marine environment.<br />

These include drift compensation and<br />

DirtAlert ® , a feature that warns service<br />

engineers via a flashing yellow LED<br />

that detectors need maintenance;<br />

and patented FasTest ® , a procedure<br />

that takes just four seconds to test<br />

smoke detectors and confirm that they<br />

are functioning correctly.<br />

Key features of Orbis Marine:<br />

• Approved for use in marine environments<br />

• Modern, low-profile design<br />

• TImeSaver Base ® for fast installation<br />

• Transient rejection for false alarm reduction<br />

• High humidity tolerance at up to 98%RH<br />

• Wide operating temperature -40°C to +70°C


Orbis Marine Optical Smoke Detector<br />

The Orbis Marine Optical Smoke Detector operates<br />

on the well established light scatter principle.<br />

However, the sensing technology is radically<br />

different in design from previous optical detectors<br />

and significantly reduces false alarms.<br />

Orbis Marine Optical Smoke ORB-OP-42001-MAR<br />

Detector<br />

Orbis Marine Optical Smoke ORB-OP-42003-MAR<br />

Detector with flashing LED<br />

Orbis Marine Multisensor Detector<br />

The Orbis Marine Multisensor Detector benefits<br />

from the same false alarm reduction technology<br />

as the optical detector. It is a thermally enhanced<br />

smoke detector and so will not give an alarm<br />

from heat alone.<br />

Orbis Marine Multisensor ORB-OH-43001-MAR<br />

Smoke Detector<br />

Orbis Marine Multisensor ORB-OH-43003-MAR<br />

Smoke Detector with flashing LED<br />

Orbis Marine Heat Detector<br />

The Orbis Marine Heat Detector uses a single<br />

thermistor to sense the air temperature around<br />

the detector. There are twelve heat detectors in<br />

the Orbis Marine range designed to suit a wide<br />

variety of operating conditions.<br />

Orbis Marine Heat Detector<br />

A1R Standard ORB-HT-41001-MAR<br />

A1R with Flashing LED ORB-HT-41013-MAR<br />

A2S Standard ORB-HT-41002-MAR<br />

A2S with Flashing LED ORB-HT-41014-MAR<br />

BR Standard ORB-HT-41003-MAR<br />

BR with Flashing LED ORB-HT-41015-MAR<br />

BS Standard ORB-HT-41004-MAR<br />

BS with Flashing LED ORB-HT-41016-MAR<br />

CR Standard ORB-HT-41005-MAR<br />

CR with Flashing LED ORB-HT-41017-MAR<br />

CS Standard ORB-HT-41006-MAR<br />

CS with Flashing LED ORB-HT-41018-MAR<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

Marine 91<br />

ORBIS MARINE<br />

• Responds well to slow-burning, smouldering<br />

fires<br />

• Performs well in detecting black and white<br />

smoke<br />

• Extra confirmation of smoke before alarm<br />

signal is given<br />

• Reduced incidents of false alarms<br />

• Sensing chamber keeps out dust and other<br />

airborne contaminants<br />

• Operates over a broad voltage range of at<br />

extremes of temperature<br />

• Flashing LED option<br />

• Responds well to fast-burning, flaming fires<br />

• Reduced incidence of false alarms<br />

• Increased reliability of <strong>detection</strong><br />

• Sensing chamber keeps out dust and other<br />

airborne contaminants<br />

• Operates over a broad range of voltages at<br />

extremes of temperature<br />

• Flashing LED option<br />

• Can be used for applications where smoke<br />

detectors are unsuitable<br />

• Ideal for environments that are dirty or smoky<br />

under normal conditions<br />

• Reduced incidences of false alarms<br />

• Increased reliability of <strong>detection</strong><br />

• Flashing LED option


92<br />

Marine<br />

ORBIS MARINE<br />

Orbis Marine TimeSaver Base ®<br />

The Orbis Marine TimeSaver Base® is a<br />

completely new design that provides installers<br />

with an open working area with fixing holes<br />

shaped to allow a simple mounting procedure.<br />

Orbis Marine TimeSaver ORB-MB-00001-MAR<br />

Base ®<br />

Orbis Marine Relay Base<br />

The Orbis Marine Relay Base incorporates a<br />

single-pole voltage-free change over contact for<br />

switching ancillary <strong>equipment</strong>. When the detector<br />

changes to the alarm state, the relay is energised,<br />

causing the contact to change state. The contact<br />

will remain in this condition until the detector is<br />

reset.<br />

Orbis Marine Relay Base ORB-RB-40004-MAR<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

• Grouped terminals to make wiring easy<br />

• Two fixing centres<br />

• LED alignment mark<br />

• Cable stripping guide<br />

• Continuity link for voltage testing of zone<br />

wiring prior to commissioning<br />

• Detector locking mechanism<br />

• Grouped terminals to make wiring easy<br />

• Two fixing centres<br />

• LED alignment mark<br />

• Cable stripping guide<br />

• Continuity link for voltage testing of zone<br />

wiring prior to commissioning<br />

• Detector locking mechanism


Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

Marine 93<br />

ORBIS MARINE


94<br />

Intrinsically Safe Detectors<br />

Intrinsically<br />

Safe<br />

Detectors<br />

There are many places where an explosive mixture of air and gas or<br />

vapour is, or may be present continuously, intermittently or as a result of<br />

an accident. These are defined as hazardous areas by BS EN 60079, the<br />

code of practice for installation and maintenance of electrical apparatus<br />

in potentially explosive atmospheres.<br />

Hazardous areas are common in petroleum and chemical engineering<br />

plants and in factories processing and storing gases, solvents, paints and<br />

other volatile substances.<br />

Electrical <strong>equipment</strong> for use in these areas needs to be designed so<br />

that it cannot ignite an explosive mixture, not only in normal operation<br />

but also in fault conditions. There are a number of methods available to<br />

achieve this but one of the most common is intrinsic safety.<br />

Apollo offer both conventional and intelligent smoke and heat detector<br />

ranges designed to be intrinsically safe, as they meet the requirements<br />

of the ATEX directive.


XP95 Intrinsically Safe (IS) detectors<br />

are a development of the well<br />

established intelligent XP95 range<br />

from Apollo. XP95 IS detectors feature<br />

all the benefits of the standard range,<br />

but are developed specifically for use<br />

in hazardous areas. The addresses of<br />

XP95 IS detectors are set by means of<br />

the patented XPERT card. See page 23<br />

for more details.<br />

Intrinsically Safe 95<br />

XP95 IS<br />

XP95 IS<br />

Intrinsically Safe<br />

Detectors


96<br />

Intrinsically Safe<br />

XP95 IS<br />

XP95 IS Ionisation Smoke Detector<br />

The XP95 IS Ionisation Smoke Detector uses a low<br />

activity radioactive foil to detect fires by irradiating<br />

the air in the smoke chambers and causing a<br />

current flow. If smoke enters the chamber, the<br />

current flow is reduced leading to an alarm.<br />

XP95 IS Ionisation Smoke Detector 55000-540<br />

XP95 IS Optical Smoke Detector<br />

The XP95 IS Optical Smoke Detector works<br />

using the light scatter principle and is ideal for<br />

applications where slow-burning or smouldering<br />

fires are likely.<br />

XP95 IS Optical Smoke Detector 55000-640<br />

XP95 IS Heat Detector<br />

The XP95 IS Heat Detector operates by measuring<br />

heat levels with a single thermistor network which<br />

gives a count output proportional to the external air<br />

temperature.<br />

XP95 IS Heat Detector 55000-440<br />

XP95 IS Mounting Base<br />

The XP95 IS Mounting Base has been designed to<br />

accept only IS products. This ensures that standard<br />

detectors cannot inadvertently be fitted into an<br />

intrinsically safe system. XPERT cards are supplied<br />

with all bases.<br />

XP95 IS Mounting Base 45681-215<br />

XP95 IS Manual Call Point<br />

- Standard Type<br />

The XP95 IS Manual Call Point is based on the<br />

standard waterproof model (58100-950), page<br />

80. It features an “interrupt” facility to provide fast<br />

response to an alarm.<br />

XP95 IS Manual Call Point Standard<br />

Without flap – Red 55100-940<br />

Without flap – Yellow † 55100-942<br />

Without flap Blue/White † 55100-944<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

† Does not have LPCB or CPD approval<br />

• Responds well to fast-burning, flaming fires<br />

• Designed to operate in a variety of<br />

environments<br />

• Minimal effects from temperature, humidity,<br />

atmospheric pressure and wind<br />

• Responds well to slow-burning, smouldering<br />

fires<br />

• Well suited for escape routes<br />

• Unaffected by wind or atmospheric pressure<br />

• Ideal for environments that are dirty or smoky<br />

under normal conditions<br />

• Unaffected by wind or atmospheric pressure<br />

• XPERT addressing<br />

• One way fit<br />

• Only accepts IS detectors<br />

• Reports an alarm in under 0.2 seconds<br />

• Waterproof<br />

• IP67


XP95 IS Manual Call Point<br />

- MEDC Style<br />

The MEDC style Manual Call Point is recommended<br />

for heavy duty applications. This model is made of<br />

glass-reinforced polyester and may be ordered as<br />

break glass or push-button style.<br />

XP95 IS Manual Call Point MEDC Style<br />

Break-glass – Red 55000-960<br />

Break-glass – Yellow 55000-962<br />

Break-glass – Blue 55000-964<br />

Break-glass – Black/Yellow Stripes 55000-966<br />

Break-glass with flap – Red 55000-961<br />

Break-glass with flap – Yellow 55000-963<br />

Break-glass with flap – Blue<br />

Break-glass with flap<br />

55000-965<br />

– Black/Yellow Stripes 55000-967<br />

Push Button – Red 55000-970<br />

Push Button – Yellow 55000-971<br />

Push Button – Blue 55000-972<br />

Push Button – Black/Yellow stripes 55000-973<br />

Protocol Translator and<br />

Galvanic Barrier<br />

The Protocol Translator and Galvanic Barrier are<br />

installed in the safe area ensuring integrity of<br />

communication between control <strong>equipment</strong><br />

and field devices and safety within the limits of<br />

BASEEFA approvals.<br />

XP95 Protocol Translator 55000-855<br />

(single channel)<br />

XP95 Protocol Translator 55000-856<br />

(dual channel)<br />

Galvanic Barrier 29600-098<br />

DIN-Rail Interface Enclosures<br />

DIN-Rail Interface Enclosures are available in two<br />

sizes and can be used for housing intrinsically safe<br />

(IS) barriers or DIN-rail mounted interfaces. A multipurpose<br />

label that features a section for use with<br />

IS systems is supplied. For non-IS systems, the<br />

part referring to IS can simply be removed.<br />

DIN-Rail Interface Enclosure (4 units) 29600-239<br />

DIN-Rail Interface Enclosure (10 units) 29600-240<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

Intrinsically Safe 97<br />

• Reports address in under 0.2 seconds<br />

• Waterproof<br />

• Robust design<br />

XP95 IS<br />

• Loop powered<br />

• Translates voltage levels from a loop driver to<br />

be compatible with IS requirements<br />

• Allows multiple interfaces to be housed<br />

together<br />

• IP67


98<br />

Intrinsically Safe<br />

ORBIS IS<br />

Orbis IS<br />

intrinsically safe<br />

Orbis IS is a range of conventional<br />

detectors which have been developed<br />

from the standard Orbis smoke and<br />

heat detectors. Orbis IS is a range with<br />

modern styling and is electronically<br />

compatible with Apollo Series 60<br />

intrinsically safe conventional detectors.<br />

Orbis IS is a demonstration of Apollo’s<br />

commitment to the market for high<br />

quality conventional detectors for use<br />

in small to medium size installations.<br />

In developing this range, Apollo has<br />

put ease of installation and reliability<br />

in daily operation at the forefront of<br />

considerations.<br />

Features include:<br />

• TimeSaver Base ®<br />

• Patented FasTest ® enabling functional testing in four<br />

seconds<br />

• DirtAlert ® indicates limit of drift compensation<br />

• Tolerates extreme operating conditions: -40°C to +70°C<br />

• False alarm reduction<br />

• Flashing LED option


Orbis IS Optical Smoke Detector<br />

The Orbis IS Optical Smoke Detector works<br />

using the light scatter principle and is ideal for<br />

applications where slow-burning or smouldering<br />

fires are likely.<br />

Orbis IS Optical Smoke ORB-OP-52027-APO<br />

Detector<br />

Orbis IS Optical Smoke ORB-OP-52028-APO<br />

Detector with flashing LED †<br />

Orbis IS Multisensor Smoke Detector<br />

The Orbis IS Multisensor Detector benefits from<br />

the same false alarm technology as the Optical<br />

Detector. It is a thermally enhanced smoke<br />

detector so will not give an alarm from heat alone.<br />

Orbis IS Multisensor ORB-OH-53027-APO<br />

Detector<br />

Orbis IS Multisensor ORB-OH-53028-APO<br />

Detector with flashing LED †<br />

Orbis IS Heat Detector<br />

The Orbis IS Heat Detector monitors temperature<br />

by using a single thermistor network which<br />

provides a voltage output proportional to the<br />

external air temperature. The Orbis IS range<br />

incorporates seven heat detector classes to suit a<br />

wide range of operating conditions.<br />

Orbis IS Heat Detector<br />

Rate of Rise, MAT 50°C<br />

A1R Standard ORB-HT-51145-APO<br />

A1R with Flashing LED †<br />

Static, MAT 50°C<br />

ORB-HT-51146-APO<br />

A1S Standard ORB-HT-51157-APO<br />

A1S with Flashing LED †<br />

Static, MAT 50°C<br />

ORB-HT-51158-APO<br />

A2S Standard ORB-HT-51147-APO<br />

A2S with Flashing LED †<br />

Rate of Rise, MAT 65°C<br />

ORB-HT-51148-APO<br />

BR Standard ORB-HT-51149-APO<br />

BR with Flashing LED †<br />

Static, MAT 65°C<br />

ORB-HT-51150-APO<br />

BS Standard ORB-HT-51151-APO<br />

BS with Flashing LED †<br />

Rate of Rise, MAT 80°C<br />

ORB-HT-51152-APO<br />

CR Standard ORB-HT-51153-APO<br />

CR with Flashing LED †<br />

Static, MAT 80°C<br />

ORB-HT-51154-APO<br />

CS Standard ORB-HT-51155-APO<br />

CS with Flashing LED † ORB-HT-51156-APO<br />

MAT (Maximum Application Temperature)<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

† Does not have VdS approval<br />

Intrinsically Safe 99<br />

ORBIS IS<br />

• Reduces false alarms<br />

• Recommended for early warning of fire in<br />

most areas<br />

• Improved sensitivity to black smoke<br />

• Compensation for slow changes in sensitivity<br />

• Algorithms for reliability of alarm<br />

• Reduces false alarms<br />

• Sensitive to fast burning, flaming fires<br />

• Improved sensitivity to black smoke<br />

• Compensation for slow changes in sensitivity<br />

• Algorithms for reliability of alarm<br />

• Can be used for applications where smoke<br />

detectors are unsuitable<br />

• Ideal for environments that are dirty or smoky<br />

under normal conditions<br />

• Reduced incidences of false alarms<br />

• Increased reliability of <strong>detection</strong>


100<br />

Intrinsically Safe<br />

ORBIS IS<br />

Orbis IS TimeSaver ® Base<br />

The IS TimeSaver ® Base is a completely new<br />

design that provides installers with an open<br />

working area with fixing holes shaped to allow a<br />

simple mounting procedure.<br />

Orbis IS Timesaver ® Base ORB-MB-50018-APO<br />

Orbis IS Adaptor<br />

The Orbis IS Adaptor enables Orbis IS detector<br />

heads to be fitted into existing Series 60 IS<br />

bases in order to upgrade systems with minimal<br />

disruption.<br />

Orbis IS Adaptor ORB-BA-50008-APO<br />

Galvanic Barrier<br />

The Galvanic barrier is installed in the safe area<br />

and ensures system integrity.<br />

Galvanic Barrier 29600-378<br />

DIN-Rail Interface Enclosures<br />

DIN-Rail Interface Enclosures are available in two<br />

sizes and can be used for housing intrinsically safe<br />

(IS) barriers or DIN-rail mounted interfaces. A multipurpose<br />

label that features a section for use with<br />

IS systems is supplied. For non-IS systems, the<br />

part referring to IS can simply be removed.<br />

DIN-Rail Interface Enclosure (4 units) 29600-239<br />

DIN-Rail Interface Enclosure (10 units) 29600-240<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

† Does not have VdS approval<br />

• Grouped terminals to make wiring easy<br />

• Two fixing centres<br />

• LED alignment mark<br />

• Detector locking mechanism<br />

• Allows an existing range to be updated<br />

with ease<br />

• Eliminates the need for re-wiring<br />

• Ideal for conventioanl hazardous areas<br />

• Enables compliance with the ATEX directive<br />

• Allows multiple interfaces to be housed<br />

together<br />

• IP67


Intrinsically Safe 101<br />

ORBIS IS


102<br />

UL<br />

UL<br />

Apollo has developed ranges of detectors for the<br />

American market and those markets which require<br />

UL classification. Apollo has carefully researched<br />

and developed the ranges to ensure that they meet<br />

not only the UL and other standards but also the<br />

demands of today’s high technology environments.


The XP95A range of analog<br />

addressable fire detectors is advanced<br />

in design and performance and offers<br />

unique features that benefit both the<br />

installer and the end user.<br />

The range is based on Apollo’s XP95 range. XP95A has a<br />

‘central intelligence’ system where all the decisions are made<br />

by the control panel. Each detector is addressed using Apollo’s<br />

patented XPERT card, supplied with the mounting bases. The<br />

XP95A range includes an ionization detector, a photo-electric<br />

detector, a heat detector, a multisensor, an isolator and a<br />

series of modules.<br />

Key features of XP95A include:<br />

• XPERT card addressing<br />

• Analog value report<br />

• Address confirmation<br />

• Alarm flag<br />

• Unobtrusive design<br />

• Error check<br />

XP95A UL<br />

UL 103<br />

XP95A


104<br />

UL<br />

XP95A<br />

XP95A Ionization Smoke Detector<br />

The XP95A Ionization Detector uses a low activity<br />

radioactive foil to detect fires by irradiating the<br />

air in the smoke chambers and causing a current<br />

flow. If smoke enters the chamber, the current<br />

flow is reduced leading to an alarm.<br />

XP95A Ionization Smoke Detector † 55000-550<br />

XP95A Ionization Smoke Detector (ULC)* 55000-555<br />

XP95A Photo-Electric Smoke<br />

Detector<br />

The XP95A Photo-Electric Smoke Detector works<br />

on the light-scatter principle and is ideal for<br />

applications where slow-burning or smouldering<br />

fires are likely.<br />

XP95A Photo-Electric Smoke Detector 55000-650<br />

XP95A Heat Detector<br />

The XP95A Heat Detector monitors temperature<br />

by using a single thermistor network which<br />

provides a voltage output proportional to the<br />

external air temperature. It is classified as an<br />

Ordinary detector by UL.<br />

XP95A Heat Detector 55000-450<br />

XP95A Multisensor<br />

The XP95A Multisensor contains a photo-electric<br />

smoke sensor and a thermistor (temperature<br />

sensor) whose outputs are combined to give the<br />

final analog value.<br />

XP95A Multisensor 55000-886<br />

XP95A Loop Powered Beam Detector<br />

The XP95A Beam Detector is made up of three<br />

main parts: the transmitter, which projects a beam<br />

of infra-red light, the receiver, which registers<br />

the light and produces an electric signal, and<br />

the interface, which processes the signal and<br />

generates alarm or fault signals.<br />

XP95A Loop Powered Beam Detector 55000-266<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

† Does not have ULC approval<br />

* Does not have UL approval<br />

• Responds well to fast-burning, flaming fires<br />

• Designed to operate in a variety of<br />

environments<br />

• Minimal effects from temperature, humidity,<br />

atmospheric pressure<br />

• Responds well to slow-burning, smouldering<br />

fires<br />

• Well suited for bedrooms and escape routes<br />

• Unaffected by atmospheric pressure<br />

• Ideal environments that are dirty or smoky<br />

under normal conditions<br />

• Well suited for warehouses, loading bays and<br />

car parks<br />

• Unaffected by wind or atmospheric pressure<br />

• Sensitive to a wide range of fires<br />

• Well suited for environments such as hotel<br />

bedrooms or warehouse loading bays<br />

• Unaffected by wind or atmospheric pressure<br />

• Loop-powered<br />

• Four selectable alarm levels<br />

• Drift Compensation<br />

• Remote interface<br />

• Simple wiring and alignment<br />

• Designed to protect large open spaces such as<br />

museums, churches and warehouses


XP95A Low Power Relay Base<br />

The XP95A Low Power Relay Base incorporates a<br />

low power relay to control field <strong>equipment</strong> such<br />

as automatic door closers.<br />

XP95A Low Power Relay Base 4” 45681-242UL<br />

For information on XPERT cards, please see page 23.<br />

XP95A Mounting Base<br />

All detectors in the XP95A range fit the XP95A<br />

Mounting Base which is a low insertion force<br />

base with stainless steel contacts for the detector<br />

terminals. XPERT cards are supplied with all bases.<br />

XP95A Mounting Base 4” 45681-210USA<br />

XP95A Mounting Base 6” 45681-225USA<br />

E-Z Fit Base<br />

The E-Z fit base is a low profile 6” mounting base<br />

for XP95A detectors.<br />

E-Z Fit Base 45681-250<br />

XP95A Isolating Base<br />

The XP95A Isolating Base senses and detects short<br />

circuit faults on XP95A loops and spurs.<br />

XP95A Isolating Base 45681-321USA<br />

XP95A Isolator<br />

The XP95A Isolator is placed at intervals on the<br />

loop and ensures that, in the case of a short<br />

circuit, only the section between the isolators will<br />

be affected. When the short circuit is removed,<br />

the isolators automatically restore power and data<br />

to the isolated section.<br />

XP95A Isolator 55000-750<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

• XPERT addressing<br />

• One way fit<br />

• Locking feature to prevent unauthorised<br />

removal<br />

• High degree of protection against<br />

unauthorized removal<br />

UL 105<br />

XP95A<br />

• Gives a set of voltage free contacts controlled<br />

by the remote output of a detector<br />

• Draws negligible current<br />

• Up to 20 devices may be installed between<br />

isolating bases<br />

• XPERT addressing<br />

• Detects wiring short-circuits using patented<br />

technology<br />

• Minimises disruption from short-circuits<br />

• Automatic de-isolation on short-circuit removal<br />

• Up to 20 devices may be installed between<br />

isolators


106<br />

UL<br />

XP95A<br />

XP95A Isolator Base<br />

The XP95A Isolator Base is unique and designed to<br />

only accept the XP95A Isolator.<br />

XP95A Isolator Base 45681-211USA<br />

XP95A Mini Priority Switch Monitor Module<br />

The XP95A Mini Priority Switch Monitor is<br />

designed to monitor the state of one or more<br />

single pole, volt free contacts and to report<br />

the status to Apollo compatible analog control<br />

<strong>equipment</strong>. It can also place a signal on the loop<br />

to provide early warning if a device such as a pull<br />

station is operated.<br />

XP95A Mini Priority Switch 55000-830<br />

Monitor Module<br />

XP95A Mini Switch Monitor Module<br />

The XP95A Mini Switch Monitor Module is<br />

designed to monitor the state of one or more<br />

single pole, volt free contacts and to report<br />

the status to Apollo compatible analog control<br />

<strong>equipment</strong>.<br />

XP95A Mini Switch Monitor Module 55000-831<br />

XP95A Switch Monitor Module<br />

The XP95A Switch Monitor Module is designed to<br />

monitor the state of one or more single pole, volt<br />

free contacts connected and to report the status<br />

to Apollo compatible analog control <strong>equipment</strong>.<br />

XP95A Switch Monitor Module 55000-805<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

• Only accepts isolators<br />

• Three input states - ’normal’, ’fault’ and ’alarm’<br />

• Visible LED with remote LED connection option<br />

• Loop powered<br />

• Designed to fit into <strong>equipment</strong> with limited space<br />

• Easy to install<br />

• Monitors <strong>equipment</strong> where a fast response<br />

is required<br />

• Interrupt facility<br />

• Three input states - ’normal’, ’fault’, and ’alarm’<br />

• Visible LED with remote LED connection option<br />

• Loop powered<br />

• Designed to fit into <strong>equipment</strong> with limited space<br />

• Easy to install<br />

• Three input states - ’normal’, ’fault’, and ’alarm’<br />

• Visible LED<br />

• Loop powered


XP95A Priority Switch Monitor<br />

Module<br />

The XP95A Priority Switch Monitor Module is<br />

designed to monitor the state of one or more<br />

single pole, volt free contacts and to report<br />

the status to Apollo compatible analog control<br />

<strong>equipment</strong>. It can also place a signal on the loop<br />

to provide early warning if a device such as a pull<br />

station is operated.<br />

XP95A Priority Switch Monitor 55000-806<br />

Module<br />

XP95A Dual Priority Switch Monitor<br />

Module<br />

The XP95A Dual Priority Switch Monitor Module<br />

contains two priority switch monitor modules<br />

(55000-806) on a single plate.<br />

XP95A Dual Priority Switch Monitor 55000-790<br />

Module<br />

XP95A Switch Monitor Input/Output<br />

Module<br />

The XP95A Switch Monitor Input/Output Module<br />

provides a voltage free, single pole, change-over<br />

relay output, a single, monitored switch input and<br />

unmonitored, non-polarized opto-coupled input.<br />

XP95A Switch Monitor 55000-820<br />

Input/Output Module<br />

XP95A Sounder Control Module<br />

The XP95A Sounder Control Module monitors and<br />

controls the operation of a zone of conventional<br />

sounders and reports their status to the control<br />

panel.<br />

XP95A Sounder Control Module 55000-825<br />

XP95A Relay Output Module<br />

The XP95A Relay Output Module provides a single<br />

2-pole changeover relay.<br />

XP95A Relay Output Module 55000-863<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

• Loop powered<br />

• Fast response time<br />

• Interrupt facility<br />

UL 107<br />

XP95A<br />

• Three input states - ’normal’, ’fault’, and ’alarm’<br />

• Two visible LEDs<br />

• Loop powered<br />

• Fast response time<br />

• Interrupt facility<br />

• It can report fault, switch open and switch<br />

closed levels<br />

• Visible LED<br />

• Loop powered<br />

• Allows sounders to be operated continuously<br />

or be pulsed, 1 second on, 1 second off<br />

• May be synchronized when in pulsed<br />

operation<br />

• Can also be used for public address speakers<br />

• Loop powered<br />

• Can be placed anywhere on loop


108<br />

UL<br />

SERIES 65A<br />

Series 65A<br />

UL<br />

Series 65A is a range of conventional<br />

fire detectors available in three<br />

versions:<br />

• Standard<br />

• Flashing LED<br />

• Flashing LED and magnet operated test switch


Series 65A Ionization Smoke<br />

Detector<br />

The Series 65A Ionization Smoke Detector uses a low<br />

activity radioactive foil to detect fires by irradiating<br />

the air in the smoke chambers and causing a<br />

current flow. If smoke enters the chamber, the<br />

current flow is reduced leading to an alarm.<br />

Series 65A Ionization Smoke Detector<br />

- Standard 55000-227<br />

Series 65A Ionization Smoke Detector 55000-226<br />

with flashing LED<br />

Series 65A Ionization Smoke Detector 55000-225<br />

with flashing LED and magnetic test switch<br />

Series 65A Photo-Electric<br />

Smoke Detector<br />

The Series 65A Photo-Electric Smoke Detector<br />

incorporates a pulsing LED located within the<br />

housing of the detector. The detector housing is<br />

identical to that of the Ionization Detector but has<br />

an indicator LED which is clear in quiescent state<br />

but produces red light in alarm.<br />

Series 65A Photo-Electric Detector<br />

- Standard 55000-327<br />

Series 65A Photo-Electric Detector 55000-326<br />

with flashing LED<br />

Series 65A Photo-Electric Detector 55000-325<br />

with flashing LED and magnetic test switch<br />

S65A Photo-Electric High Sensitivity 55000-328<br />

Series 65A Heat Detector<br />

The Series 65A Heat Detector monitors<br />

temperature by using a dual thermistor network<br />

which provides a voltage output proportional to<br />

the external air temperature.There are nine heat<br />

detectors in the Series 65A range designed to suit<br />

a wide variety of operating conditions.<br />

Series 65A Heat Detector<br />

135°F - Standard 55000-140<br />

135°F - flashing LED 55000-139<br />

135°F - flashing LED and magnetic 55000-138<br />

test switch<br />

170°F - Standard 55000-143<br />

170°F - flashing LED 55000-142<br />

170°F - flashing LED and magnetic 55000-141<br />

test switch<br />

200°F - Standard 55000-146<br />

200°F - flashing LED 55000-145<br />

200°F - flashing LED and magnetic 55000-144<br />

test switch<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

SERIES 65A<br />

• Responds well to fast burning, flaming fires<br />

• Designed to operate in a variety of<br />

environments<br />

• Wide operating voltage<br />

• Flashing LED option<br />

• Flashing LED and magnet operated test switch<br />

option<br />

• Responds well to slow-burning, smouldering<br />

fires<br />

• Well suited for bedrooms and escape routes<br />

• Unaffected by wind or atmospheric pressure<br />

• Wide operating voltage<br />

• Flashing LED option<br />

• Flashing LED and magnet operated test<br />

switch option<br />

• Can be used for applications where smoke<br />

detectors are unsuitable<br />

• Ideal environments that are dirty or smoky<br />

under normal conditions<br />

• Wide operating voltage<br />

• Flashing LED option<br />

• Flashing LED and magnet operated test<br />

switch option<br />

UL 109


110<br />

UL<br />

SERIES 65A<br />

Series 65A Standard Base<br />

The Series 65A Base has been designed to enable<br />

detectors to be fitted without the need of force<br />

– particularly useful when fitting to suspended<br />

ceilings. All Series 65A bases have a ‘one way<br />

only’ fit.<br />

Series 65A Base 4” 45681-200USA<br />

Series 65A Base 6” 48681-220USA<br />

Series 65A Standard Relay Base 4”<br />

The Standard Series 65A Relay Base provides one<br />

set of volt-free, changeover (form C) contacts that<br />

change state when the detector signals an alarm.<br />

Series 65A Standard Relay Base 4” 45681-255<br />

Series 65A Auxiliary Relay Base 4”<br />

The Series 65A Auxiliary Relay Base provides two<br />

sets of volt-free changeover contacts to facilitate<br />

the switching of a remote LED or other auxiliary<br />

device.<br />

Series 65A Auxiliary Relay Base 4” 45681-256<br />

Series 65A End-of-Line Relay Base<br />

The Series 65A End-of-Line (EOL) Relay Base is<br />

intended for use with 4-wire circuits and feature<br />

two sets of changeover contacts and a power<br />

supervision relay.<br />

Series 65A 12V End-of-Line Relay<br />

Base 4” 45681-257<br />

Series 65A 24V End-of-Line Relay<br />

Base 4” 45681-258<br />

Series 65A Low Profile Base 6”<br />

A low profile mounting base for Series 65A<br />

detectors.<br />

Series 65A Low Profile Base 6” 45681-232<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

• Detector locking mechanism<br />

• One way fit<br />

• Easy to wire<br />

• Contains a ground wire terminal<br />

• Contains no electrical parts<br />

• Detector locking mechanism<br />

• One way fit<br />

• Easy to wire<br />

• Contains a ground wire terminal<br />

• Detector locking mechanism<br />

• One way fit<br />

• Easy to wire<br />

• Contains a ground wire terminal<br />

• Detector locking mechanism<br />

• One way fit<br />

• Easy to wire<br />

• Contains a ground wire terminal<br />

• Detector locking mechanism<br />

• One way fit<br />

• Easy to wire<br />

• Contains a ground wire terminal


Series 65A E-Z Fit Base 6”<br />

A low profile mounting base for Series 65A<br />

detectors.<br />

Series 65A E-Z Fit Base 6” 45681-251<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

SERIES 65A<br />

• High degree of protection against unauthorized<br />

removal<br />

UL 111


112<br />

UL<br />

DISCOVERY UL<br />

Discovery<br />

UL<br />

Discovery UL is a range of highspecification,<br />

intelligent fire detectors<br />

developed to meet the requirements of<br />

sophisticated systems while providing<br />

engineers with an additional dimension<br />

in fire protection capability. Discovery<br />

UL has a ‘distributed intelligence<br />

system’ where decisions are made in<br />

the detector head as well as at the<br />

control panel. Drift compensation is<br />

also incorporated into the detector,<br />

allowing it to adapt to dirty or dusty<br />

environments, which reduces false<br />

alarms.<br />

Each detector in the Discovery UL range can operate in<br />

one of five response modes, which can be selected from<br />

the control panel. The response characteristics have<br />

been carefully set so that the detectors comply with the<br />

requirements of the relevant part of UL in all response<br />

modes. Mode One will give a higher sensitivity to fire<br />

than Mode five.<br />

Discovery gives you total reassurance in installations where<br />

adaptability to changing conditions and protection against<br />

unwanted alarms are paramount.<br />

Key features of Discovery UL include:<br />

• Rejection of transient signals<br />

• Flashing LED option<br />

• Five response modes for ease of optimization to<br />

changing environments<br />

• Drift compensation to ensure constant sensitivity<br />

• Four bytes of non-volatile memory for user data<br />

• Alarm flag for fast alarm reporting<br />

• Conventional alarm facility during control panel<br />

processor fault<br />

• 360° visibility in alarm<br />

• Compatible with XP95A systems


Discovery UL Ionization Smoke<br />

Detector<br />

The Ionization detector uses a low activity<br />

radioactive foil to detect fires by irradiating the<br />

air in the smoke chambers and causing a current<br />

flow. If smoke enters the chamber, the current<br />

flow is reduced leading to an alarm.<br />

Discovery UL Ionization Smoke 58000-550<br />

Detector<br />

Discovery UL Photo-Electric Smoke<br />

Detector<br />

The Discovery UL Photo-Electric Smoke Detector<br />

works using the light scatter principle and is<br />

ideal for applications where slow-burning or<br />

smouldering fires are likely.<br />

Discovery UL Photo-Electric 58000-650<br />

Smoke Detector<br />

Discovery UL Heat Detector<br />

The Discovery UL Heat Detector, distinguishable<br />

by the low airflow resistant case, uses a single<br />

thermistor to sense the air temperature around<br />

the detector.<br />

Discovery UL Heat Detector 58000-450<br />

Discovery UL Multisensor Detector<br />

The Discovery UL Multisensor Detector comprises<br />

optical smoke and thermistor temperature sensors<br />

whose outputs are combined to give the final<br />

analog value. As a result, the Multisensor is useful<br />

over a wide range of applications and is highly<br />

immune to false alarms.<br />

Discovery UL Multisensor Detector 58000-750<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

DISCOVERY UL<br />

• Responds well to fast-burning, flaming fires<br />

• Designed to operate in a variety of<br />

environments<br />

• Remote test feature<br />

• Responds well to slow-burning, smouldering<br />

fires<br />

• Well suited for bedrooms and escape routes<br />

• Unaffected by wind or atmospheric pressure<br />

• Remote test feature<br />

• Ideal environments that are dirty or smoky<br />

under normal conditions<br />

• Well suited for warehouses, loading bays and<br />

car parks<br />

• Unaffected by wind or atmospheric pressure<br />

• Remote test feature<br />

• Ideal for wide range of applications<br />

• Highly immune to false alarms<br />

• Well suited for sensitive environments<br />

• Unaffected by wind or atmospheric pressure<br />

• Remote test feature<br />

UL 113


114<br />

UL<br />

DISCOVERY UL<br />

XP95A Mounting Base<br />

All detectors in the Discovery UL range fit the<br />

XP95A Mounting Base. The Mounting Base is<br />

a low insertion force base with stainless steel<br />

contacts for the detector terminals. XPERT cards<br />

are supplied with all bases.<br />

XP95A Mounting Base 4” 45681-210USA<br />

XP95A Mounting Base 6” 45681-225USA<br />

E-Z Fit Base<br />

The E-Z Fit Base is a low profile 6” mounting base<br />

for Discovery UL detectors.<br />

E-Z Fit Base 45681-250<br />

XP95A Isolating Base<br />

The XP95A Isolating Base senses and detects short<br />

circuit faults on Discovery UL loops and spurs.<br />

XP95A Isolating Base 45681-321USA<br />

XP95A Isolator<br />

The XP95A Isolator can be used on a Discovery<br />

UL loop and is placed at intervals on the loop and<br />

ensures that, in the case of a short circuit, only<br />

the section between the isolators will be affected.<br />

When the short circuit is removed, the isolators<br />

automatically restore power and data to the<br />

isolated section.<br />

XP95A Isolator 55000-750<br />

XP95A Isolator Base<br />

The XP95A Isolator Base is unique and designed to<br />

only accept the XP95A isolator. However, both can<br />

be used with a Discovery UL system.<br />

XP95A Isolator Base 45681-211USA<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

• XPERT addressing<br />

• One way fit<br />

• Locking feature to prevent unauthorised<br />

removal<br />

• High degree of protection against unauthorised<br />

removal<br />

• Up to 20 devices may be installed between<br />

isolating bases<br />

• Detects wiring short circuits using patented<br />

technology<br />

• Minimises disruption from short-circuits<br />

• Automatic de-isolation on short-circuit removal<br />

• Up to 20 devices may be installed between<br />

isolators<br />

• Only accepts the XP95A Isolator


DISCOVERY UL<br />

UL 115


116<br />

Test Equipment and Maintenance<br />

Test<br />

Equipment &<br />

Maintenance<br />

To keep a fire <strong>detection</strong> system in good working<br />

order, it should be subject to a routine maintenance<br />

programme in accordance with locally applicable<br />

regulations. Over the course of a year, every<br />

detector in the system should be functionally tested<br />

at least once, using recommended <strong>equipment</strong>.<br />

Apollo offer a range of test <strong>equipment</strong>, for both<br />

conventional and intelligent systems to enable you<br />

to do this.


XP95 Test Set<br />

The XP95 Test Set is a self-contained, portable<br />

test unit capable of providing a number of useful<br />

functions in relation to individual detectors,<br />

ancillary devices or complete circuits of analogue<br />

addressable devices in the Apollo intelligent<br />

ranges. The main function of the test set is to help<br />

the engineer guarantee correct loop configuration<br />

before an active control panel is installed.<br />

XP95 Test Set 55000-870EUR<br />

Discovery Programmer<br />

The Discovery Programmer is a portable test and<br />

configuration tool for Discovery smoke and heat<br />

detectors.<br />

Discovery Programmer 53832-030<br />

Accessories:<br />

Conventional Test Set<br />

The Conventional Test Set is an invaluable tool<br />

designed to give a thorough on-site check of<br />

conventional fire detectors within the Apollo<br />

Series 65 and AlarmSense range. Each Test Set<br />

is supplied with a link head, mains adaptor and<br />

carrying case with shoulder strap.<br />

Conventional Test Set 53832-020<br />

Flame Sensor Test Unit and Case<br />

The Flame Sensor Test Kit is a tool which is<br />

designed to test flame detectors without the<br />

need of real flames.<br />

Test Equipment and Maintenance 117<br />

TEST EQUIPMENT AND MAINTENANCE<br />

• User friendly LCD information display<br />

• Speedy commissioning<br />

• Option for hard copy of results<br />

• No unnecessary site visits<br />

• Significant cost reductions<br />

• Look up the date of manufacture<br />

• Check the drift compensation value<br />

• Display and change the operating mode<br />

• Select/de-select LED flash mode<br />

• Tests detectors<br />

• Reads approval codes<br />

Product Name Part Number<br />

Printer for XP95 Test Set 55000-872<br />

Flame Sensor Test Unit and Case 29600-226<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

• Easy to use<br />

• 2 button select/accept options<br />

• LCD for clear display<br />

• Mimics the characteristics of real flames


118<br />

Test Equipment and Maintenance<br />

TEST EQUIPMENT AND MAINTENANCE<br />

In addition to the main test kits, Apollo provide a range of <strong>equipment</strong><br />

to enable you to keep your system in good working order.<br />

Product Name<br />

FOR INSTALLATION AND REMOVAL OF DETECTORS:<br />

Part Number<br />

Detector Extract Tool 29600-102<br />

Extension Pole, 1.13m 29600-103<br />

Telescopic Pole, 1.26m to 4.5m 29600-104<br />

1.5mm Hexagonal Driver (locks detectors to bases) 29600-095<br />

XPERT Card Insertion Tool<br />

FOR IN SITU FUNCTIONAL TESTING OF INDIVIDUAL DETECTORS:<br />

Solo<br />

45681-235<br />

Smoke Dispenser Head 29600-100<br />

Aerosol Test Gas 29600-225<br />

Heat Detector Test Pole (240V) 29600-229<br />

Heat Detector Test Pole (110V) 29600-231<br />

Cordless Heat Tester Kit 29600-212<br />

Cordless Heat Detector Tester 29600-213<br />

CO Test Gas 29600-235<br />

Detector Duster 29600-449<br />

Battery Batons 29600-183<br />

Battery Charger*<br />

Testifire<br />

29600-214<br />

Smoke/Heat Unit 29600-459<br />

Smoke/Heat Kit 29600-460<br />

Smoke/Heat/CO Unit 29600-461<br />

Smoke/Heat/CO Kit 29600-462<br />

6-Pack Replacement Smoke Capsule 29600-463<br />

3-Pack Replacement Smoke Capsule 29600-464<br />

6-Pack Replacement CO Capsule 29600-465<br />

3-Pack Replacement CO Capsule 29600-466<br />

Battery Batons 29600-183<br />

Battery Charger* 29600-214<br />

Aerosol Test Gas<br />

29600-225<br />

CO Test Gas<br />

29600-235<br />

Telescopic Pole,<br />

1.26m to 4.5m<br />

29600-104<br />

Please check the Apollo website on a regular basis for up-to-date approvals information.<br />

*When ordering please state if you require an EU lead or UK lead.<br />

Extension Pole,1.13m<br />

29600-103


Test Equipment and Maintenance 119<br />

TEST EQUIPMENT AND MAINTENANCE


120<br />

Additional Services<br />

Additional<br />

Services


Loop Calculator<br />

The Apollo Loop Calculator is a free computer programme used<br />

to establish the viability of a design. It enables engineers to<br />

calculate the total loop loading in a proposed Discovery or XP95<br />

fire <strong>detection</strong> system by inputting relevant variables, for example<br />

control <strong>equipment</strong>, loop devices and cable length and type.<br />

Parameters are included for Apollo protocol compatible panels.<br />

Please see the Apollo website for more details<br />

www.apollo-fire.co.uk/loop-calc<br />

SimSystem<br />

SimSystem is a tool for simulating loops of detectors and<br />

interfaces in order to demonstrate a system and prove the<br />

design without having to connect actual products to a control<br />

panel. SimSystem consists of a software programme which<br />

features an intuitive graphical display and an interface which<br />

runs up to four loops. A maximum of two interfaces can be<br />

connected, thus allowing a system of up to eight loops to be<br />

simulated.<br />

Training<br />

Apollo offers a series of free one-day training courses for its<br />

customers. The courses cover the following modules:<br />

Module 1: Detection Principles & Device Selection<br />

Module 1.1: Carbon Monoxide <strong>Fire</strong> Detection (Coming soon)<br />

Module 2: Conventional Detector Operation<br />

Module 2.1: AlarmSense<br />

Module 2.2: Orbis (Coming soon)<br />

Module 3: Analogue Addressable Principles<br />

Module 3.1: XP95<br />

Module 3.2: Discovery<br />

Module 3.3: XPlorer<br />

Module 3.4: AV Alarm Devices (Coming soon)<br />

Module 3.5: XPander<br />

Module 4: Intrinsically Safe Equipment (Coming soon)<br />

Module 5: Service, Test & Maintenance<br />

In addition to the standard training courses, Apollo can offer<br />

tailor-made courses if required. The majority of courses are held<br />

at Apollo’s head office, but on-site training is also available.<br />

You can find out more about Apollo’s training days and book your<br />

place by visiting www.apollo-fire.co.uk/training<br />

Additional Services 121


122<br />

Approvals<br />

Approvals<br />

Apollo <strong>Fire</strong> Detectors has a library that contains<br />

hundreds of different types of product certificate<br />

that have been obtained from many different<br />

national and international bodies. Listed below is<br />

a small selection. Please see our website for more<br />

details and up-to-date approvals information.<br />

Loss Prevention Certification Board (LPCB)<br />

The LPCB is an international certification body who<br />

specialises in the fields of security and fire protection. LPCB<br />

approval is recognised by governments and regulatory<br />

authorities worldwide, particularly in Europe, the Asia-Pacific<br />

and the Middle East. The LPCB approval process involves<br />

the assessment and testing of products to ensure that they<br />

meet quality standards set by a team of industry experts.<br />

Testing is carried out in-house by LPCB and the approval<br />

is maintained by regular audits to ensure that the product<br />

continues to meet the approval criteria.<br />

Apollo products with LPCB approval:<br />

Orbis<br />

Class A1R Heat Detector ORB-HT-11001-APO<br />

Class A1R Heat Detector with flashing LED ORB-HT 11013-APO<br />

Class A1S Heat Detector ORB-HT-11166-APO<br />

Class A1S Heat Detector with flashing LED ORB-HT-11167-APO<br />

Class A2S Heat Detector ORB-HT-11002-APO<br />

Class A2S Heat Detector with flashing LED ORB-HT-11014-APO<br />

Class BR Heat Detector ORB-HT-11003-APO<br />

Class BR Heat Detector with flashing LED ORB-HT-11015-APO<br />

Class BS Heat Detector ORB-HT-11004-APO<br />

Class BS Heat Detector with flashing LED ORB-HT-11016-APO<br />

Class CR Heat Detector ORB-HT-11005-APO<br />

Class CR Heat Detector with flashing LED ORB-HT-11017-APO<br />

Class CS Heat Detector ORB-HT-11006-APO<br />

Class CS Heat Detector with flashing LED ORB-HT-11018-APO<br />

Optical Smoke Detector ORB-OP-12001-APO<br />

Optical Smoke Detector with flashing LED ORB-OP-12003-APO<br />

Multisensor Smoke Detector ORB-OH-13001-APO<br />

Multisensor Smoke Detector ORB-OH-13003-APO<br />

with flashing LED<br />

TimeSaver Base ORB-MB-00001-APO<br />

TimeSaver Base LX ORB-MB-00002-APO<br />

TimeSaver Relay Base ORB-RB-10004-APO<br />

TimeSaver Deep Base ORB-MB-00019-APO<br />

Orbis IS<br />

Class A1R Heat Detector ORB-HT-51145-APO<br />

Class A1R Heat Detector with flashing LED ORB-HT-51146-APO<br />

Class A1S Heat Detector ORB-HT-51147-APO<br />

Class A1S Heat Detector with flashing LED ORB-HT-51158-APO<br />

Class A2S Heat Detector ORB-HT-51157-APO<br />

Class A2S Heat Detector with flashing LED ORB-HT-51148-APO<br />

Class BR Heat Detector ORB-HT-51149-APO<br />

Class BR Heat Detector with flashing LED ORB-HT-51150-APO<br />

Class BS Heat Detector ORB-HT-51151-APO<br />

Class BS Heat Detector with flashing LED ORB-HT-51152-APO<br />

Class CR Heat Detector ORB-HT-51153-APO<br />

Class CR Heat Detector with flashing LED ORB-HT-51154-APO<br />

Class CS Heat Detector ORB-HT-51155-APO<br />

Class CS Heat Detector with flashing LED ORB-HT-51156-APO<br />

Multisensor Detector ORB-OH-53027-APO<br />

Multisensor Detector with flashing LED ORB-OH-53028-APO<br />

Optical Smoke Detector ORB-OP-52027-APO<br />

Optical Smoke Detector with flashing LED ORB-OP-52028-APO<br />

Adaptor ORB-BA-10008-APO<br />

TimeSaver Base ORB-MB-50018-APO<br />

Series 65<br />

Class A1R Heat Detector with<br />

flashing LED and magnetic test switch<br />

55000-120<br />

Class A1R Heat Detector with flashing LED 55000-121<br />

Class A1R Heat Detector 55000-122<br />

Class BR Heat Detector with<br />

flashing LED and magnetic test switch<br />

55000-125<br />

Class BR Heat Detector with flashing LED 55000-126<br />

Class BR Heat Detector 55000-127<br />

Class CR Heat Detector with<br />

flashing LED and magnetic test switch<br />

55000-130<br />

Class CR Heat Detector with flashing LED 55000-131<br />

Class CR Heat Detector 55000-132<br />

Class CS Heat Detector with<br />

flashing LED and magnetic test switch<br />

55000-135<br />

Class CS Heat Detector with flashing LED 55000-136<br />

Class CS Heat Detector 55000-137<br />

Integrating Ionisation Smoke Detector<br />

with flashing LED and magnetic test switch<br />

55000-218


Integrating Ionisation Smoke Detector 55000-219<br />

with flashing LED<br />

Integrating Ionisation Smoke Detector 55000-220<br />

Ionisation Smoke Detector with 55000-215<br />

flashing LED and magnetic test switch<br />

Ionisation Smoke Detector with flashing LED 55000-216<br />

Ionisation Smoke Detector 55000-217<br />

Optical Smoke Detector with 55000-315<br />

flashing LED and magnetic test switch<br />

Optical Smoke Detector with flashing LED 55000-316<br />

Optical Smoke Detector 55000-317<br />

Standard Base 45681-200<br />

Diode Base 45681-201<br />

Standard Relay Base 45681-245<br />

Auxiliary Contacts Base 45681-246<br />

Relay 12V EOL Base 45681-247<br />

Relay 24V EOL Base 45681-248<br />

XP95<br />

Class CS Heat Detector 55000-401<br />

Class A2S Heat Detector 55000-400<br />

Ionisation Smoke Detector 55000-500<br />

Optical Smoke Detector 55000-600<br />

Multisensor Detector 55000-885<br />

Mounting Base 45681-210<br />

20D Isolating Base 45681-284<br />

Low Power Relay Base 45681-242<br />

Manual Call Point (Surface) 55100-905<br />

Manual Call Point with Isolator (Surface) 55100-908<br />

Isolator Base 45681-211<br />

XP95 Interfaces<br />

Three Channel Input/Output Unit 55000-588<br />

Switch Monitor Plus 55000-841<br />

Switch Monitor 55000-843<br />

Zone Monitor 55000-845<br />

Input/Output Unit 55000-847<br />

Output Unit 55000-849<br />

Sounder Control Unit 55000-852<br />

XP95 IS<br />

Class A2S Heat Detector 55000-440<br />

Ionisation Smoke Detector 55000-540<br />

Optical Smoke Detector 55000-640<br />

Standard Manual Call Point 55100-940<br />

Standard Base 45681-215<br />

Discovery<br />

Heat Detector - Variable Temperature 58000-400<br />

Ionisation Smoke Detector 58000-500<br />

Optical Smoke Detector 58000-600<br />

Multisensor Detector 58000-700<br />

Mounting Base 45681-210<br />

20D Isolating Base 45681-284<br />

Manual Call Point (Surface) 58100-908<br />

Manual Call Point (Surface) 58100-910<br />

Approvals 123<br />

VdS<br />

VdS is an international and independent testing and<br />

certification body based in Germany who specialises in the<br />

fields of fire prevention and security. With over 100 years<br />

experience, VdS inspects and certifies products to ensure<br />

they meet standards jointly established by VdS and industry<br />

experts.<br />

Apollo products with VdS approval:<br />

Orbis<br />

Class A1R Heat Detector ORB-HT-11001-APO<br />

Class A1S Heat Detector ORB-HT-11166-APO<br />

Class A2S Heat Detector ORB-HT-11002-APO<br />

Class BR Heat Detector ORB-HT-11003-APO<br />

Class BS Heat Detector ORB-HT-11004-APO<br />

Class CR Heat Detector ORB-HT-11005-APO<br />

Class CS Heat Detector ORB-HT-11006-APO<br />

Optical Smoke Detector ORB-OP-12001-APO<br />

Multisensor Smoke Detector ORB-OH-13001-APO<br />

TimeSaver Base ORB-MB-00001-APO<br />

TimeSaver LX Base ORB-MB-00002-APO<br />

TimeSaver Diode Base ORB-DB-00003-APO<br />

TimeSaver Relay Base ORB-RB-10004-APO<br />

Orbis IS<br />

Class A1R Heat Detector ORB-HT-51145-APO<br />

Class A1S Heat Detector ORB-HT-51147-APO<br />

Class A2S Heat Detector ORB-HT-51157-APO<br />

Class BR Heat Detector ORB-HT-51149-APO<br />

Class BS Heat Detector ORB-HT-51151-APO<br />

Class CR Heat Detector ORB-HT-51153-APO<br />

Class CS Heat Detector ORB-HT-51155-APO<br />

Multisensor Detector ORB-OH-53027-APO<br />

Optical Smoke Detector ORB-OP-52027-APO<br />

Adaptor ORB-BA-10008-APO<br />

TimeSaver Base ORB-MB-50018-APO<br />

Series 65<br />

Class A1R Heat Detector 55000-122<br />

Class BR Heat Detector 55000-127<br />

Class CR Heat Detector 55000-132<br />

Class CS Heat Detector 55000-137<br />

Ionisation Smoke Detector 55000-217<br />

Integrating Ionisation Smoke Detector 55000-220<br />

Optical Smoke Detector 55000-317<br />

Standard Base 45681-200<br />

Standard Relay Base 45681-245<br />

Auxiliary Contacts Base 45681-246<br />

Relay Base - 12V EOL 45681-247<br />

Relay Base - 24V EOL 45681-248<br />

XP95<br />

XP95 Heat Detector 55000-420<br />

Ionisation Smoke Detector 55000-520<br />

Optical Smoke Detector 55000-620


124<br />

Approvals<br />

Multisensor Detector 55000-885<br />

20D Positive Short Circuit Isolator 55000-710<br />

20D Negative Short Circuit Isolator 55000-720<br />

Isolator Base 45681-211<br />

Interfaces<br />

Three Channel Input/Output Unit 55000-588<br />

Switch Monitor Plus 55000-841<br />

Switch Monitor 55000-843<br />

Zone Monitor 55000-845<br />

Input/Output Unit 55000-847<br />

Output Unit 55000-849<br />

Sounder Control Unit 55000-852<br />

Sounders<br />

Integrated Base Sounder DIN tone 45681-300<br />

Sounder Beacon Base 45681-334<br />

Discovery<br />

Variable Temperature Heat Detector 58000-400<br />

Ionisation Smoke Detector 58000-500<br />

Optical Smoke Detector 58000-600<br />

Multisensor Detector 58000-700<br />

Mounting Base 45681-210<br />

UL<br />

Underwriters Laboratories (UL) is an independent<br />

product certification body based in the United States.<br />

UL test products against standards set by a team of industry<br />

experts and potential customers. There are no laws which<br />

specify that a UL mark must be used on a product, however,<br />

in the US there are many municipalities that have laws,<br />

codes or regulations which require a product to be tested by<br />

a recognised testing laboratory such as UL before it can be<br />

sold in their area.<br />

Apollo products with UL approval:<br />

Series 65A<br />

Heat Detector 135°F - flashing LED 55000-138<br />

and magnetic test switch<br />

Heat Detector 135°F - flashing LED 55000-139<br />

Heat Detector 135°F - Standard 55000-140<br />

Heat Detector 170°F - flashing LED 55000-141<br />

and magnetic test switch<br />

Heat Detector 170°F - flashing LED/ 55000-142<br />

Heat Detector 170°F - Standard 55000-143<br />

Heat Detector 200°F - flashing LED 55000-144<br />

and magnetic test switch<br />

Heat Detector 200°F - flashing LED 55000-145<br />

Heat Detector 200°F - Standard 55000-146<br />

Ionization Smoke Detector - flashing LED 55000-225<br />

and magnetic test switch<br />

Ionization Smoke Detector with flashing LED 55000-226<br />

Ionization Smoke Detector - Standard 55000-227<br />

Photo-Electric Smoke Detector flashing LED 55000-325<br />

and magnetic test switch<br />

Photo-Electric Smoke Detector 55000-326<br />

with flashing LED<br />

Photo-Electric Smoke Detector - Standard 55000-327<br />

Standard Base 4” 45681-200<br />

Standard Base 6” 45681-220<br />

Low Profile Base 6” 45681-232<br />

E-Z Fit Base 45681-251<br />

4” Conventional Standard Relay Base 45681-255<br />

4” Conventional Auxiliary Contact Base 45681-256<br />

4” Conventional Relay 12V EOL Base 45681-257<br />

4” Conventional Relay 24V EOL Base 45681-258<br />

XP95A<br />

Beam Detector 55000-266<br />

High Temperature Heat Detector 55000-450<br />

Ionization Smoke Detector 55000-550<br />

Photo-Electric Smoke Detector 55000-650<br />

Multisensor Detector 55000-886<br />

Negative Isolator 55000-750<br />

4” Addressable Base 45681-210<br />

Isolator Base 45681-211<br />

6” Addressable Base 45681-225<br />

6” Addressable Low Profile Relay Base 45681-242<br />

6” Addressable E-Z Fit Base 45681-250<br />

20D Negative Isolating Base 45681-321<br />

XP95A Interfaces<br />

Dual Switch Monitor 55000-790<br />

Switch Monitor 55000-805<br />

Priority Switch Monitor 55000-806<br />

Switch Monitor Input/Output Unit 55000-820<br />

Sounder Control Unit 55000-825<br />

Mini Priority Switch Monitor 55000-830<br />

Mini Switch Monitor 55000-831<br />

Relay Output Module 55000-863<br />

Discovery<br />

Variable Temperature Heat Detector 58000-450<br />

Ionization Smoke Detector 58000-550<br />

Photo-Electric Smoke Detector 58000-650<br />

Multisensor Detector 58000-750<br />

ULC (Underwriters Laboratory of Canada)<br />

ULC is an independent product certification body that<br />

undertakes the quarterly inspection of manufacturers to<br />

ensure continued compliance of UL Listed/Recognised<br />

products to Agency reports and safety standards. This<br />

work is done under contract to UL Inc (Follow-up Services<br />

Division). They are not a branch or subsidiary of UL.<br />

Apollo products with ULC approval:<br />

XP95A<br />

Ionization Smoke Detector 55000-555<br />

Photo-Electric Smoke Detector 55000-650<br />

Heat Detector 55000-450


Isolator 55000-750<br />

Multisensor Detector 55000-886<br />

Mounting Base 4” 45681-210USA<br />

Isolator Base 45681-211<br />

Mounting Base 6” 45681-225USA<br />

Low Power Relay Base 4” 45681-242<br />

E-Z Fit Base 45681-250<br />

Isolating Base 45681-321<br />

XP95A Interfaces<br />

Mini Priority Switch Monitor Module 55000-830<br />

Mini Switch Monitor Module 55000-831<br />

Switch Monitor Module 55000-805<br />

Priority Switch Monitor Module 55000-806<br />

Switch Monitor Input/Output Module 55000-820<br />

Sounder Control Module 55000-825<br />

Relay Output Module 55000-863<br />

Series 65A<br />

Photo-Electric Smoke Detector Standard 55000-327<br />

Photo-Electric Smoke Detector with 55000-326<br />

flashing LED<br />

Photo-Electric Smoke Detector with 55000-325<br />

flashing LED and magnetic test switch<br />

135°F Heat Detector Standard 55000-140<br />

135°F Heat Detector with flashing LED 55000-139<br />

135°F Heat Detector with flashing LED 55000-138<br />

and magnetic test switch<br />

170°F Heat Detector Standard 55000-143<br />

170°F Heat Detector with flashing LED 55000-142<br />

170°F Heat Detector with flashing LED 55000-141<br />

and magnetic test switch<br />

200°F Heat Detector Standard 55000-146<br />

200°F Heat Detector with flashing LED 55000-145<br />

200°F Heat Detector with flashing LED 55000-144<br />

and magnetic test switch<br />

Standard Relay Base 4” 45681-255<br />

Auxiliary Relay Base 4” 45681-256<br />

12V End-of-Line Relay Base 4” 45681-257<br />

24V End-of-Line Relay Base 4” 45681-258<br />

E-Z Fit Base 6” 45681-251<br />

Discovery UL<br />

Photo-Electric Smoke Detector 58000-650<br />

Heat Detector 58000-450<br />

Multisensor Detector 58000-750<br />

Mounting Base 4” 45681-210USA<br />

Mounting Base 6” 45681-225USA<br />

E-Z Fit Base 45681-250<br />

FM<br />

FM Approvals certifies products and services with a<br />

unique focus on objectively testing property loss prevention<br />

products and services and certifying those that meet<br />

rigorous loss prevention standards.<br />

Apollo products with FM approval:<br />

XP95A<br />

Ionization Smoke Detector 55000-550<br />

Photo-Electric Smoke Detector 55000-650<br />

Heat Detector 55000-450<br />

Mounting Base 4” 45681-210USA<br />

Mounting Base 6” 45681-225USA<br />

Isolator 55000-750<br />

Discovery UL<br />

Mounting Base 4” 45681-210USA<br />

Mounting Base 6” 45681-225USA<br />

Isolator 55000-750<br />

CCCF<br />

<strong>Fire</strong> Product Type Approval or CCCF Approval is a<br />

compulsory certification for fire products entering the<br />

China market.<br />

Apollo products with CCCF approval:<br />

XP95<br />

Grade 2 Heat Detector 55000-420<br />

Ionisation Smoke Detector 55000-520<br />

Optical Smoke Detector 55000-620<br />

Surface Mount Manual Call Point 55000-905<br />

Flush Mount Manual Call Point 55000-906<br />

Discovery<br />

Discovery Heat Detector 58000-400MAC<br />

Discovery Ionisation Smoke Detector 58000-500MAC<br />

Discovery Optical Smoke Detector 58000-600MAC<br />

Discovery Multisensor Detector 58000-700MAC<br />

Discovery UL Heat Detector 58000-450<br />

Discovery UL Ionization Smoke Detector 58000-550<br />

Discovery UL Photo-Electric Smoke Detector 58000-650<br />

Discovery UL Multisensor Detector 58000-750<br />

Discovery Manual call Point with Isolator 58100-908<br />

Red (Surface)<br />

Discovery Manual Call Point - Red (Surface) 58100-910<br />

Approvals 125<br />

Orbis<br />

Orbis Optical Smoke Detector with ORB-OP-12003-PRC<br />

flashing LED<br />

Orbis Multisensor with flashing LED ORB-OH-13003-PRC<br />

Orbis A1R Heat Detector with flashing LED ORB-HT-11013-PRC<br />

Orbis A2S Heat Detector with flashing LED ORB-HT-11014-PRC<br />

Orbis BR Heat Detector with flashing LED ORB-HT-11015-PRC<br />

Orbis BS Heat Detector with flashing LED ORB-HT-11016-PRC<br />

Orbis CR Heat Detector with flashing LED ORB-HT-11017-PRC<br />

Orbis CS Heat Detector with flashing LED ORB-HT-11018-PRC<br />

Orbis Marine Optical Smoke Detector ORB-OP-42003-MAC<br />

with flashing LED<br />

Orbis Marine Multisensor Detector ORB-OH-43003-MAC<br />

with flashing LED<br />

Orbis Marine A1R Heat Detector with flashing LED ORB-HT-41013-MAC


126<br />

Approvals<br />

Orbis Marine A2S Heat Detector with flashing LED ORB-HT-41014-MAC<br />

Orbis Marine BR Heat Detector with flashing LED ORB-HT-41015-MAC<br />

Orbis Marine BS Heat Detector with flashing LED ORB-HT-41016-MAC<br />

Orbis Marine CR Heat Detector with flashing LED ORB-HT-41017-MAC<br />

Orbis Marine CS Heat Detector with flashing LED ORB-HT-41018-MAC<br />

XP95<br />

XP95 Waterproof Manual Call Point 55000-950<br />

Orbis IS Detectors<br />

Orbis IS A1R Heat Detector with flashing LED ORB-HT-51146-PRC<br />

Orbis IS A2S Heat Detector with flashing LED ORB-HT-51148-PRC<br />

Orbis IS BR Heat Detector with flashing LED ORB-HT-51150-PRC<br />

Orbis IS BS Heat Detector with flashing LED ORB-HT-51152-PRC<br />

Orbis IS CR Heat Detector with flashing LED ORB-HT-51154-PRC<br />

Orbis IS CS Heat Detector with flashing LED ORB-HT-51156-PRC<br />

Orbis IS Optical Smoke Detector with flashing LED ORB-OP-52028-PRC<br />

Orbis IS Multisensor with flashing LED ORB-OH-53028-PRC<br />

XP95 IS<br />

XP95 IS Heat Detector 55000-440<br />

XP95 IS Ionisation Smoke Ddetector 55000-540<br />

XP95 IS Optical Smoke Detector 55000-640<br />

XP95 IS Manual Call Point without flap - red 55000-940<br />

XP95 IS Manual Call Point MEDC 58100-970<br />

Push Button -red<br />

XP95 IS Manual Call Point MEDC 58100-971<br />

Push Button - yellow<br />

Construction Products Directive (CPD)<br />

The CPD is one of the ‘New Approach’ Directives to<br />

create a single European market by removing technical<br />

barriers to trade between Member States. Products which<br />

meet the essential requirements of the relevant directives<br />

will be eligible for CE marking and may be placed on the<br />

market anywhere within the EEA.<br />

Apollo products with CPD approval:<br />

AlarmSense<br />

Integrating Optical Detector 55000-391<br />

Heat Detector A1R 55000-190<br />

Heat Detector CS 55000-193<br />

Base 45681-244<br />

Sounder Base LR 45681-341<br />

Sounder Base 45681-510<br />

Sounder Beacon Base LR 45681-509<br />

Sounder Beacon Base 45681-509<br />

Manual Call Point (Surface) 55000-894<br />

Series 65<br />

Class A1R Heat Detector with 55000-120<br />

flashing LED and magnetic test switch<br />

Class A1R Heat Detector with flashing LED 55000-121<br />

Class A1R Heat Detector 55000-122<br />

Class BR Heat Detector with 55000-125<br />

flashing LED and magnetic test switch<br />

Class BR Heat Detector with flashing LED 55000-126<br />

Class BR Heat Detector 55000-127<br />

Class CR Heat Detector with 55000-130<br />

flashing LED and magnetic test switch<br />

Class CR Heat Detector with flashing LED 55000-131<br />

Class CR Heat Detector 55000-132<br />

Class CS Heat Detector with 55000-135<br />

flashing LED and magnetic test switch<br />

Class CS Heat Detector with flashing LED 55000-136<br />

Class CS Heat Detector 55000-137<br />

French Ionisation Smoke Detector 55000-208<br />

French Optical Smoke Detector 55000-308<br />

Ionisation Smoke Detector with 55000-215<br />

flashing LED and magnetic test switch<br />

Ionisation Smoke Detector with flashing LED 55000-216<br />

Ionisation Smoke Detector 55000-217<br />

Integrating Ionisation Smoke Detector 55000-218<br />

with flashing LED and magnetic test switch<br />

Integrating Ionisation Smoke Detector 55000-219<br />

with flashing LED<br />

Integrating Ionisation Smoke Detector 55000-220<br />

Optical Smoke Detector with 55000-315<br />

flashing LED and magnetic test switch<br />

Optical Smoke Detector with flashing LED 55000-316<br />

Optical Smoke Detector 55000-317<br />

Standard Base 45681-200<br />

Standard Relay Base 45681-245<br />

Auxiliary Relay Base 45681-246<br />

Relay 12V EOL Base 45681-247<br />

Relay 24V EOL Base 45681-248<br />

Orbis<br />

Class A1R Heat Detector ORB-HT-11001-APO<br />

Class A1R Heat Detector with flashing LED ORB-HT 11013-APO<br />

Class A1S Heat Detector ORB-HT-11166-APO<br />

Class A1S Heat Detector with flashing LED ORB-HT-11167-APO<br />

Class A2S Heat Detector ORB-HT-11002-APO<br />

Class A2S Heat Detector with flashing LED ORB-HT-11014-APO<br />

Class BR Heat Detector ORB-HT-11003-APO<br />

Class BR Heat Detector with flashing LED ORB-HT-11015-APO<br />

Class BS Heat Detector ORB-HT-11004-APO<br />

Class BS Heat Detector with flashing LED ORB-HT-11016-APO<br />

Class CR Heat Detector ORB-HT-11005-APO<br />

Class CR Heat Detector with flashing LED ORB-HT-11017-APO<br />

Class CS Heat Detector ORB-HT-11006-APO<br />

Class CS Heat Detector with flashing LED ORB-HT-11018-APO<br />

Optical Smoke Detector ORB-OP-12001-APO<br />

Optical Smoke Detector with flashing LED ORB-OP-12003-APO<br />

Multisensor Smoke Detector ORB-OH-13001-APO<br />

Multisensor Smoke Detector ORB-OH-13003-APO<br />

with flashing LED<br />

TimeSaver Base ORB-MB-00001-APO<br />

TimeSaver Base LX ORB-MB-00002-APO<br />

TimeSaver Deep Base ORB-MB-00019-APO


Orbis IS<br />

Class A1R Heat Detector ORB-HT-51145-APO<br />

Class A1R Heat Detector with flashing LED ORB-HT-51146-APO<br />

Class A1S Heat Detector ORB-HT-51157-APO<br />

Class A1S Heat Detector with flashing LED ORB-HT-51158-APO<br />

Class A2S Heat Detector ORB-HT-51147-APO<br />

Class A2S Heat Detector with flashing LED ORB-HT-51148-APO<br />

Class BR Heat Detector ORB-HT-51149-APO<br />

Class BR Heat Detector with flashing LED ORB-HT-51150-APO<br />

Class BS Heat Detector ORB-HT-51151-APO<br />

Class BS Heat Detector with flashing LED ORB-HT-51152-APO<br />

Class CR Heat Detector ORB-HT-51153-APO<br />

Class CR Heat Detector with flashing LED ORB-HT-51154-APO<br />

Class CS Heat Detector ORB-HT-51155-APO<br />

Class CS Heat Detector with flashing LED ORB-HT-51156-APO<br />

Multisensor Detector ORB-OH-53027-APO<br />

Multisensor Detector with flashing LED ORB-OH-53028-APO<br />

Optical Smoke Detector ORB-OP-52027-APO<br />

Optical Smoke Detector with flashing LED ORB-OP-52028-APO<br />

Adaptor ORB-BA-10008-APO<br />

TimeSaver Base ORB-MB-50018-APO<br />

XP95<br />

Class A2S Heat Detector 55000-400<br />

Class CS Heat Detector 55000-401<br />

Ionisation Smoke Detector 55000-500<br />

Optical Smoke Detector 55000-600<br />

Multisensor Smoke Detector 55000-885<br />

Mounting Base 45681-210<br />

Isolating Base 45681-284<br />

XP95 Interfaces<br />

Three Channel Input/Output Unit 55000-588<br />

Switch Monitor Plus 55000-841<br />

Switch Monitor 55000-843<br />

Zone Monitor 55000-845<br />

Input/Output Unit 55000-847<br />

Output Unit 55000-849<br />

Sounder Control Unit 55000-852<br />

XP95 IS<br />

Class A2S Heat Detector 55000-440<br />

Ionisation Smoke Detector 55000-540<br />

Optical Smoke Detector 55000-640<br />

Base 55000-215<br />

Manual Call Point (Red) 55000-940<br />

Discovery<br />

Heat Detector 58000-400<br />

Ionisation Smoke Detector 58000-500<br />

Isolating Base 45681-284<br />

Optical Smoke Detector 58000-600<br />

Multisensor Detector 58000-700<br />

Mounting Base 45681-210<br />

Base Sounders<br />

Integrated Base Sounder with Isolator 45681-277<br />

Integrated Base Sounder 45681-278<br />

Slow Whoop Integrated Base Sounder 45681-290<br />

with Isolator<br />

Slow Whoop Integrated Base Sounder 45681-291<br />

Integrated Base Sounder with 45681-300<br />

Short Circuit Isolator (DIN tone)<br />

Intelligent Base Sounder 45681-265<br />

Intelligent Base Sounder for Isolating Base 45681-266<br />

Intelligent Base Sounder Slow Whoop 45681-267<br />

Intelligent Base Sounder Slow Whoop 45681-268<br />

for Isolating Base<br />

Series 65 Sounder Base 45681-512<br />

Series 65 Sounder Base with Diode 45681-513<br />

Sounder Beacon<br />

Multi-Tone Open Area Sounder Beacon Red 55000-291<br />

Sounder Beacon Base with Isolator 45681-330<br />

Sounder Beacon Base 45681-331<br />

Slow Whoop Sounder Beacon Base 45681-332<br />

with Isolator<br />

Sounder Beacon Base 45681-334<br />

with Isolator (DIN Tone)<br />

Sounders<br />

100dB(A) Loop-Powered Sounder Red 55000-278<br />

100dB(A) Loop-Powered Sounder White 55000-279<br />

100dB(A) Loop-Powered Sounder 55000-276<br />

Slow Whoop Red<br />

100dB(A) Loop-Powered Sounder 55000-277<br />

Slow Whoop White<br />

Weatherproof 100dB(A) Sounder Red 55000-274<br />

Weatherproof 100dB(A) Sounder White 55000-275<br />

Approvals 127<br />

XPander<br />

XPander Optical Smoke Detector and<br />

Mounting Base XPA-CB-12034-APO<br />

XPander Multisensor Detector and<br />

Mounting Base XPA-CB-13032-APO<br />

XPander A1R Heat Detector and<br />

Mounting Base XPA-CB-11170-APO<br />

XPander CS Heat Detector and Mounting<br />

Base XPA-CB-11171-APO<br />

XPander Manual Call Point XPA-MC-14006-APO<br />

XPander Sounder and Sounder Base Red XPA-CB-14001-APO<br />

XPander Sounder and Sounder Base White XPA-CB-14002-APO<br />

XPander Sounder Beacon and Sounder<br />

Base Red XPA-CB-14003-APO<br />

XPander Sounder Beacon Amber and<br />

Sounder Base White XPA-CB-14004-APO<br />

XPander Sounder Beacon and Sounder<br />

Base White XPA-CB-14005-APO


128<br />

Approvals<br />

ATEX<br />

The ATEX directive is compulsory for all <strong>equipment</strong><br />

which is used in a hazardous area (where an explosive<br />

atmosphere might occur). The name ATEX comes from the<br />

French ATmospheres EXplosibles.<br />

Apollo products with ATEX approval:<br />

XP95 IS<br />

Ionisation Detector 55000-540<br />

Optical Smoke Detector 55000-640<br />

Heat Detector 55000-440<br />

Base 45681-215<br />

IS Standard Manual Call Points 55000-940/942/<br />

944<br />

IS MEDC Manual Call Points 55000-960/962/<br />

964/966/961/963/<br />

965/967<br />

Orbis IS<br />

Class A1R Heat Detector ORB-HT-51145-APO<br />

Class A1R Heat Detector with flashing LED ORB-HT-51146-APO<br />

Class A1S Heat Detector ORB-HT-51157-APO<br />

Class A1S Heat Detector with flashing LED ORB-HT-51158-APO<br />

Class A2S Heat Detector ORB-HT-51147-APO<br />

Class A2S Heat Detector with flashing LED ORB-HT-51148-APO<br />

Class BR Heat Detector ORB-HT-51149-APO<br />

Class BR Heat Detector with flashing LED ORB-HT-51150-APO<br />

Class BS Heat Detector ORB-HT-51151-APO<br />

Class BS Heat Detector with flashing LED ORB-HT-51152-APO<br />

Class CR Heat Detector ORB-HT-51153-APO<br />

Class CR Heat Detector with flashing LED ORB-HT-51154-APO<br />

Class CS Heat Detector ORB-HT-51155-APO<br />

Class CS Heat Detector with flashing LED ORB-HT-51156-APO<br />

Multisensor Detector ORB-OH-53027-APO<br />

Multisensor Detector with flashing LED ORB-OH-53028-APO<br />

Optical Smoke Detector ORB-OP-52027-APO<br />

Optical Smoke Detector with flashing LED ORB-OP-52028-APO<br />

TimeSaver Base ORB-MB-50018-APO


26729-152 Transparent Hinged Cover for<br />

Manual Call Point .............................................................79<br />

27249-005 Deckhead Adaptor PG16-M20 ...................................84<br />

29600-095 1.5mm Hexagonal Driver .............................................85<br />

29600-098 IS Galvanic Barrier ............................................................97<br />

29600-100 Smoke Dispenser Head ........................................... 118<br />

29600-101 Heat Detector Test Pole (240V) ............................. 118<br />

29600-102 Detector Extract Tool ................................................. 118<br />

29600-103 Extension Pole, 1.13m .............................................. 118<br />

29600-104 Telescopic Pole, 1.26m to 4.5m ............................ 118<br />

29600-110 Heat Detector Test Pole (110V) ............................ 118<br />

29600-131 Metal Deckhead Mounting Box (PG16) .................84<br />

29600-139 Metal Deckhead Mounting Box (M20)...................84<br />

29600-183 Battery Batons ............................................................. 118<br />

29600-203 Flame Detector Bracket ................................................47<br />

29600-206 Flame Detector Weathershield ..................................47<br />

29600-212 Cordless Heat Tester Kit ........................................... 118<br />

29600-213 Cordless Heat Detector Tester ............................... 118<br />

29600-214 Battery Charger ............................................................. 118<br />

29600-225 Aerosol Test Gas ......................................................... 118<br />

29600-226 Flame Sensor Test Unit and Case .......................... 117<br />

29600-235 CO Test Gas .................................................................... 118<br />

29600-239 DIN-Rail Interface Enclosure (4 units) .............. 77, 85<br />

29600-240 DIN-Rail Interface Enclosure (10 units) ........... 77, 85<br />

29600-241 Reflective Beam Detector Backbox .........................49<br />

29600-256 White Cap ...........................................................................56<br />

29600-257 Red Cap ...............................................................................56<br />

29600-318 Beacon Enclosure .............................................59, 67, 84<br />

29600-350 <strong>Fire</strong>beam Beam Detector 5-40m .............................49<br />

29600-351 <strong>Fire</strong>beam Extension Kit 40-80m ................................49<br />

29600-352 <strong>Fire</strong>beam Extension Kit 80-100m .............................49<br />

29600-353 <strong>Fire</strong>beam Adaptor Plate ................................................49<br />

29600-378 Galvanic Barier ............................................................... 100<br />

29600-449 Detector Duster ............................................................. 118<br />

29600-458 Base Mounted Flame Detector Bracket .................47<br />

29600-459 Smoke/Heat Unit .......................................................... 118<br />

29600-460 Smoke/Heat Kit ............................................................. 118<br />

29600-461 Smoke/Heat/CO Unit .................................................. 118<br />

29600-462 Smoke/Heat/CO Kit..................................................... 118<br />

29600-463 6-Pack Replacement Smoke Capsule .................. 118<br />

29600-464 3-Pack Replacement Smoke Capsule .................. 118<br />

29600-465 6-Pack Replacement CO Capsule ........................... 118<br />

29600-466 3-Pack Replacement CO Capsule ........................... 118<br />

29650-001 Magnetic Wand ................................................................67<br />

38531-771 Blank XPERT Card .............................................................23<br />

38531-822 Module Base .....................................................................83<br />

45681-200 Series 65 Standard Base ...............................................31<br />

45681-200USA Series 65A 4” Standard Base ................................... 110<br />

45681-201 Series 65 Diode Base .....................................................31<br />

45681-204 Conduit Box .......................................................................83<br />

45681-206 Series 65 Sav-Wire Base ..............................................32<br />

45681-209 Intelligent Deep Base ...............................................11,19<br />

45681-210 Intelligent Mounting Base .................................... 11, 18<br />

45681-210USA XP95A 4” Mounting Base ................................ 105,114<br />

45681-210MAR Discovery Marine Mounting Base .............................89<br />

45681-211 Isolator Base .............................................................. 12, 18<br />

45681-211USA XP95A Isolator Base ........................................... 105,114<br />

45681-211MAR Discovery Marine Isolator Base .................................89<br />

Index: Sequential Part Number List 129<br />

Index<br />

Sequential Part<br />

Number List<br />

45681-215 XP95 IS Mounting Base .................................................96<br />

45681-217 Polycarbonate Deckhead Mounting<br />

Box ...................................................................12,19, 28, 84<br />

45681-219 Intelligent Heater Base .......................................... 12, 19<br />

45681-220USA Series 65A 6” Standard Base.................................. 110<br />

45681-225USA XP95A 6” Mounting Base ................................ 105,114<br />

45681-232 Series 65A 6” Low Profile Base .............................. 110<br />

45681-233 Backplate ............................................................................83<br />

45681-235 XPERT Card Insertion Tool ........................................ 118<br />

45681-238 Series 90 to XP95 Base Adaptor ...............................85<br />

45681-242 Intelligent Low Power Relay Base .................... 12, 19<br />

45681-242UL XP95A 4” Low Power Relay Base ......................... 105<br />

45681-244 AlarmSense Base ............................................................37<br />

45681-245 Series 65 Standard Relay Base .................................32<br />

45681-246 Series 65 Auxiliary Relay Base ..................................32<br />

45681-247 Series 65 End-of-Line Relay Base (12V).................32<br />

45681-248 Series 65 End-of-Line Relay Base (24V).................32<br />

45681-250 E-Z Fit Base ............................................................. 105,114<br />

45681-251 Series 65A 6” E-Z Fit Base ......................................... 111<br />

45681-255 Series 65A 4” Standard Relay Base ...................... 110<br />

45681-256 Series 65A 4” Auxiliary Relay Base ....................... 110<br />

45681-257 Series 65A 4” 12V End-of-Line Relay Base ........ 110<br />

45681-258 Series 65A 4” 24V End-of-Line Relay Base ........ 110<br />

45681-265 Intelligent Base Sounder .............................................56<br />

45681-266 Intelligent Base Sounder for Isolating Base ...........56<br />

45681-267 Intelligent Base Sounder Slow Whoop ..................56<br />

45681-268 Intelligent Base Sounder Slow Whoop<br />

for Isolating Base .............................................................56<br />

45681-276 Ancillary Base Sounder ..................................................56<br />

45681-277 Integrated Base Sounder with Isolator ...................56<br />

45681-278 Integrated Base Sounder ..............................................56<br />

45681-284 Isolating Base ..............................................................11,18<br />

45681-290 Integrated Base Sounder - Slow Whoop<br />

with Isolator .......................................................................56


130<br />

Index: Sequential Part Number List<br />

45681-291 Integrated Base Sounder - Slow Whoop ...............56<br />

45681-292 White Cap ................................................................... 56, 65<br />

45681-293 Red Cap ....................................................................... 56, 65<br />

45681-294 AlarmSense White Cap ......................................... 57, 65<br />

45681-295 AlarmSense Red Cap ............................................. 57, 65<br />

45681-300 Integrated Base Sounder DIN-Tone with Isolator .56<br />

45681-309 Detector Ceiling Tile Mounting Box ..........................84<br />

45681-310 Sounder Ceiling Tile Mounting Box...........................84<br />

45681-311 Sounder Ceiling Plate .....................................................83<br />

45681-321 Intelligent Isolating Base ....................................... 11, 18<br />

45681-321USA XP95A Isolating Base ......................................... 105,114<br />

45681-330 Sounder Beacon Base with Isolator .........................65<br />

45681-331 Sounder Beacon Base .................................................65<br />

45681-332 Sounder Beacon Base Slow Whoop<br />

with Isolator .......................................................................65<br />

45681-333 Loop Powered Beacon Base with Isolator ............61<br />

45681-334 Sounder Beacon Base with Isolator DIN-Tone ....65<br />

45681-335 Loop-Powered Beacon Base Standard Flash .......61<br />

45681-336 Sounder Beacon Base with Australian Tone ........65<br />

45681-337 Loop-Powered Beacon Base with<br />

Australian Flash ................................................................61<br />

45681-338 Sounder Beacon Base with NZ Tone .......................65<br />

45681-340 AlarmSense Sounder Beacon Base LR ....................65<br />

45681-341 AlarmSense Sounder Base LR ...................................57<br />

45681-370 Series 65 Base Cover ....................................................83<br />

45681-380 XP95 Base Cover ............................................................83<br />

45681-393 Discovery Sounder Beacon Base ..............................65<br />

45681-508 Series 65 12V Relay Base ............................................32<br />

45681-509 AlarmSense Sounder Beacon Base ........................65<br />

45681-510 AlarmSense Sounder Base ..........................................57<br />

45681-512 Series 65 Sounder Base .............................................57<br />

45681-513 Series 65 Sounder Base with Diode ........................57<br />

45682-127 Pre-Addressed XPERT Cards........................................23<br />

53546-021 Conventional Duct Detector ........................................51<br />

53546-022 Intelligent Duct Detector ...............................................51<br />

53546-023 Orbis Duct Detector ........................................................51<br />

53832-020 Conventional Test Set ................................................. 117<br />

53832-030 Discovery Programmer .............................................. 117<br />

53832-070 MiniDisc Remote Indicator ..............12,19, 28, 33, 37<br />

55000-001 Intelligent Open-Area Sounder Red .........................54<br />

55000-002 Intelligent Open-Area Sounder White .....................54<br />

55000-005 Intelligent Open-Area Sounder Beacon Red..............<br />

Lens .......................................................................................63<br />

55000-006 Intelligent Open-Area Sounder Beacon<br />

Clear Lens ...........................................................................63<br />

55000-009 Intelligent Open-Area Beacon Red Lens ...................59<br />

55000-010 Intelligent Open-Area Beacon Clear Lens) ...............59<br />

55000-020 Intelligent IR 3 Flame Detector .....................................46<br />

55000-021 Intelligent Flameproof IR 3 Flame Detector ............46<br />

55000-022 Intelligent Base Mounted UV Flame Detector .....47<br />

55000-023 Intelligent Base Mounted UV IR² Flame Detector ..47<br />

55000-024 Intelligent Base Mounted IR 3 Flame Detector .........47<br />

55000-120 Series 65 A1R Heat Detector flashing LED<br />

and magnetic test switch ............................................31<br />

55000-121 Series 65 A1R Heat Detector ....................................31<br />

55000-122 Series 65 A1R Heat Detector Standard ..................31<br />

55000-125 Series 65 BR Heat Detector flashing LED<br />

and magnetic test switch ............................................31<br />

55000-126 Series 65 BR Heat Detector flashing LED ...............31<br />

55000-127 Series 65 BR Heat Detector Standard .....................31<br />

55000-130 Series 65 CR Heat Detector flashing LED<br />

and magnetic test switch ............................................31<br />

55000-131 Series 65 CR Heat Detector flashing LED ...............31<br />

55000-132 Series 65 CR Heat Detector Standard ......................31<br />

55000-135 Series 65 CS Heat Detector flashing LED<br />

and magnetic test switch ............................................31<br />

55000-136 Series 65 CS Heat Detector flashing LED ................31<br />

55000-137 Series 65 CS Heat Detector Standard ......................31<br />

55000-138 Series 65A 135˚F Heat Detector flashing LED<br />

and magnetic test switch ......................................... 109<br />

55000-139 Series 65A 135˚F Heat Detector flashing LED ... 109<br />

55000-140 Series 65A 135˚F Heat Detector Standard .......... 109<br />

55000-141 Series 65A 170˚F Heat Detector flashing LED<br />

and magnetic test switch ........................................ 109<br />

55000-142 Series 65A 170˚F Heat Detector flashing LED .. 109<br />

55000-143 Series 65A 170˚F Heat Detector Standard ........ 109<br />

55000-144 Series 65A 200˚F Heat Detector flashing LED<br />

and magnetic test switch ......................................... 109<br />

55000-145 Series 65A 200˚F Heat Detector flashing LED ... 109<br />

55000-146 Series 65A 200˚F Heat Detector Standard .......... 109<br />

55000-182 DIN-Rail Sounder Controller (5 Amperes)..............76<br />

55000-190 AlarmSense A1R Heat Detector (Standard) .........36<br />

55000-193 AlarmSense CS Heat Detector (High Temp) ........36<br />

55000-196 AlarmSense A1R Heat Detector and<br />

Sounder Base ....................................................................36<br />

55000-197 AlarmSense CS Heat Detector and<br />

Sounder Base ....................................................................36<br />

55000-198 AlarmSense A1R Heat Detector and<br />

Sounder Beacon Base ...................................................36<br />

55000-199 AlarmSense CS Heat Detector and<br />

Sounder Beacon Base ...................................................36<br />

55000-215 Series 65 Ionisation Smoke Detector<br />

flashing LED and magnetic test switch ...................30<br />

55000-216 Series 65 Ionisation Smoke Detector<br />

flashing LED ........................................................................30<br />

55000-217 Series 65 Ionisation Smoke Detector Standard ...30<br />

55000-218 Series 65 Integrating Ionisation Smoke<br />

Detector flashing LED and magnetic test switch ......30<br />

55000-219 Series 65 Integrating Ionisation Smoke<br />

Detector flashing LED .....................................................30<br />

55000-220 Series 65 Integrating Ionisation Smoke Detector ..30<br />

55000-225 Series 65A Ionization Smoke Detector<br />

flashing LED and magnetic test switch ................ 109<br />

55000-226 Series 65A Ionization Smoke Detector<br />

flashing LED .................................................................. 109<br />

55000-227 Series 65A Ionization Smoke Detector<br />

Standard ........................................................................... 109<br />

55000-266 XP95A Loop Powered Beam Detector ................ 104<br />

55000-268 Reflective Beam Detector (5-50m) .........................49<br />

55000-273 Reflective Beam Detector (50-100m) ....................49<br />

55000-274 Intelligent 100dB(A) Weatherproof Sounder<br />

Open-Area Red ................................................................54<br />

55000-275 Intelligent 100dB(A) Weatherproof Sounder<br />

Open-Area White ............................................................54<br />

55000-276 Intelligent 100dB(A) Open-Area Sounder<br />

Slow Whoop Red .............................................................54<br />

55000-277 Intelligent 100dB(A) Open-Area Sounder<br />

Slow Whoop White.........................................................54<br />

55000-278 Intelligent 100dB(A) Open-Area Sounder Red ....54<br />

55000-279 Intelligent 100dB(A) Open-Area Sounder<br />

White ....................................................................................54<br />

55000-280 Intelligent IR² Flame Detector .....................................46


55000-291 Multi-Tone Open Area Sounder Beacon Red .......63<br />

55000-292 Multi-Tone Open Area Sounder Beacon White ...63<br />

55000-293 Multi-Tone Open Area Sounder Beacon Red<br />

with Isolator .......................................................................63<br />

55000-294 Multi-Tone Open Area Sounder Beacon White<br />

with Isolator .......................................................................63<br />

55000-295 Flameproof Intelligent IR² Flame Detector ............46<br />

55000-296 Weatherproof Multi-Tone Open Area Sounder<br />

Beacon Red ........................................................................63<br />

55000-297 Weatherproof Multi-Tone Open Area Sounder<br />

Beacon White ...................................................................63<br />

55000-298 Weatherproof Multi-Tone Open Area Sounder<br />

Beacon Red with Isolator .............................................63<br />

55000-299 Weatherproof Multi-Tone Open Area Sounder<br />

Beacon White with Isolator .........................................63<br />

55000-315 Series 65 Optical Smoke Detector flashing<br />

LED and magnetic test switch ....................................30<br />

55000-316 Series 65 Optical Smoke Detector flashing LED 30<br />

55000-317 Series 65 Optical Smoke Detector Standard ........30<br />

55000-325 Series 65A Photo-Electric Smoke Detector<br />

flashing LED and magnetic test switch ................ 109<br />

55000-326 Series 65A Photo-Electric Smoke Detector<br />

flashing LED .................................................................. 109<br />

55000-327 Series 65A Photo-Electric Smoke Detector<br />

Standard ........................................................................... 109<br />

55000-390 AlarmSense Optical Smoke Detector ......................36<br />

55000-391 AlarmSense Integrating Optical Smoke<br />

Detector ..............................................................................36<br />

55000-392 AlarmSense Optical Smoke Detector and<br />

Sounder Base ....................................................................36<br />

55000-393 AlarmSense Integrating Optical Smoke<br />

Detector and Sounder Base ........................................36<br />

55000-394 AlarmSense Optical Smoke Detector and<br />

Sounder Beacon Base ...................................................36<br />

55000-395 AlarmSense Integrating Optical Smoke<br />

Detector and Sounder Beacon Base ........................36<br />

55000-400 XP95 Heat Detector A2S ..............................................17<br />

55000-401 XP95 Heat Detector CS .................................................17<br />

55000-440 XP95 IS Heat Detector ...................................................96<br />

55000-450 XP95A Heat Detector ................................................. 104<br />

55000-500 XP95 Ionisation Smoke Detector ..............................17<br />

55000-540 XP95 IS Ionisation Smoke Detector..........................96<br />

55000-550 XP95A Ionization Smoke Detector ........................ 104<br />

55000-588 Three Channel Input/Output Unit ..............................70<br />

55000-600 XP95 Optical Smoke Detector ....................................17<br />

55000-640 XP95 IS Optical Smoke Detector ...............................96<br />

55000-650 XP95A Photo-Electric Smoke Detector ................ 104<br />

55000-700MAR Discovery Marine Isolator .............................................89<br />

55000-720 Isolator ...........................................................................11,18<br />

55000-750 XP95A Isolator ..................................................... 105,114<br />

55000-760 Mini Switch Monitor ............................................... 74, 77<br />

55000-765 Mini Monitor Module .................................................. 106<br />

55000-790 XP95A Dual Priority Switch Monitor Module ..... 107<br />

55000-802 DIN-Rail Dual Isolator ......................................................77<br />

55000-803 DIN-Rail Input/Output Unit ...........................................76<br />

55000-804 DIN-Rail Output Unit .......................................................76<br />

55000-805 XP95A Switch Monitor Module .............................. 106<br />

55000-806USA XP95A Priority Switch Monitor Module ............... 107<br />

55000-812 DIN-Rail Zone Monitor with Isolator .........................77<br />

55000-820USA XP95A Switch Monitor Input/Output Module ... 107<br />

55000-821 DIN-Rail Switch Monitor Plus ......................................77<br />

Index: Sequential Part Number List 131<br />

55000-822 DIN-Rail Switch Monitor ................................................76<br />

55000-825 XP95A Sounder Control Module ............................. 107<br />

55000-826 DIN-Rail Sounder Control Unit .....................................80<br />

55000-830 XP95A Mini Priority Switch Monitor Module ..... 106<br />

55000-831 XP95A Mini Switch Monitor Module .................... 106<br />

55000-832 Mini Switch Monitor with fly leads (Interrupt).....74<br />

55000-833 Mini Switch Monitor with fly leads ...........................74<br />

55000-835 AlarmSense Alarm Relay ............................................37<br />

55000-841 Switch Monitor Plus ........................................................71<br />

55000-843 Switch Monitor .................................................................71<br />

55000-845 Zone Monitor Unit ...........................................................71<br />

55000-847 Input/Output Unit ............................................................70<br />

55000-849 Output Unit .........................................................................70<br />

55000-852 Sounder Control Unit ......................................................70<br />

55000-855 XP95 Protocol Translator (Single Channel) ............97<br />

55000-856 XP95 Protocol Translator (Dual Channel) ...............97<br />

55000-863 XP95A Relay Output Module ................................... 107<br />

55000-870 XP95 Test Set ................................................................. 117<br />

55000-872 Printer for XP95 Test Set ........................................... 117<br />

55000-875 Mains Switching Input/Output Unit ..........................71<br />

55000-877 Loop-Powered Beacon Red ........................................59<br />

55000-878 Loop-Powered Beacon Clear Lens Red Flash .......59<br />

55000-879 Loop-Powered Beacon Amber ..................................59<br />

55000-885 XP95 Multisensor Detector ..........................................17<br />

55000-886 XP95A Multisensor Detector ................................... 104<br />

55000-894 AlarmSense Manual Call Point (Surface) ...............80<br />

55100-940 XP95 IS Manual Call Point Without Flap - Red ......96<br />

55100-942 XP95 IS Manual Call Point Without Flap - Yellow ..96<br />

55100-944 XP95 IS Manual Call Point Without Flap -<br />

Blue/White .........................................................................96<br />

55000-945 XP95 IS Manual Call Point With Flap -<br />

Blue/White .........................................................................96<br />

55000-960 XP95 IS Manual Call Point MEDC Break<br />

Glass - Red .........................................................................97<br />

55000-961 XP95 IS Manual Call Point MEDC Break<br />

Glass with flap - Red ......................................................97<br />

55000-962 XP95 IS Manual Call Point MEDC Break<br />

Glass - Yellow ...................................................................97<br />

55000-963 XP95 IS Manual Call Point MEDC Break<br />

Glass with flap - Yellow ................................................97<br />

55000-964 XP95 IS Manual Call Point MEDC Break<br />

Glass - Blue ........................................................................97<br />

55000-965 XP95 IS Manual Call Point MEDC Break<br />

Glass with flap - Blue .....................................................97<br />

55000-966 XP95 IS Manual Call Point MEDC Break<br />

Glass - Black/Yellow Stripes ........................................97<br />

55000-967 XP95 IS Manual Call Point MEDC Break<br />

Glass with flap - Black/Yellow Stripes ....................97<br />

55000-970 XP95 IS Manual Call Point MEDC Push<br />

Button - Red ......................................................................97<br />

55000-971 XP95 IS Manual Call Point MEDC Push<br />

Button - Yellow ................................................................97<br />

55000-972 XP95 IS Manual Call Point MEDC Push<br />

Button - Blue .....................................................................97<br />

55000-973 XP95 IS Manual Call Point MEDC Push<br />

Button - Black/Yellow Stripes.....................................97<br />

55100-905 XP95 Manual Call Point - Red (Surface) .................79<br />

55100-908 XP95 Manual Call Point with Isolator - Red<br />

(Surface) .............................................................................79<br />

58000-300 Discovery CO <strong>Fire</strong> Detector..........................................10<br />

58000-400 Discovery Heat Detector ..............................................10


132<br />

Index: Sequential Part Number List<br />

58000-400MAR Discovery Marine Heat Detector ...............................88<br />

58000-450 Discovery UL Heat Detector .................................... 113<br />

58000-500 Discovery Ionisation Smoke Detector .....................10<br />

58000-500MAR Discovery Marine Ionisation Smoke Detector .....88<br />

58000-550 Discovery UL Ionization Smoke Detector ............ 113<br />

58000-600 Discovery Optical Smoke Detector...........................10<br />

58000-600MAR Discovery Marine Optical Smoke Detector ...........88<br />

58000-650 Discovery UL Photo-Electric Smoke Detector ... 113<br />

58000-700 Discovery Multisensor Detector ................................10<br />

58000-700MAR Discovery Marine Multisensor ....................................88<br />

55000-797 DIN-Rail Mains Input/Output Unit .............................76<br />

58000-750 Discovery UL Multisensor Detector ....................... 113<br />

58100-908 Discovery Manual Call Point with Isolator -<br />

Red (Surface) ....................................................................79<br />

58100-910 Discovery Manual Call Point - Red (Surface) ........79<br />

51800-920 Discovery Manual Call Point (non standard)<br />

White ...................................................................................79<br />

51800-927 Discovery Manual Call Point (non standard)<br />

Yellow ..................................................................................79<br />

58100-928 Discovery Manual Call Point (non standard)<br />

Blue .......................................................................................79<br />

58100-929 Discovery Manual Call Point (non standard)<br />

Green ...................................................................................79<br />

58100-950 Waterproof Manual Call Point - Red ........................80<br />

58100-951 Waterproof Manual Call Point with Isolator -<br />

Red ........................................................................................80<br />

58100-970MAR Discovery Marine Manual Call Point .......................89<br />

ORB-BA-10008-APO S65 to Orbis Base Adaptor ..........................................85<br />

ORB-BA-50008-APO Orbis IS Adaptor ............................................................ 100<br />

ORB-DB-00003-APO TimeSaver Diode Base ..................................................27<br />

ORB-HB-00020-APO Orbis Heater Base ...........................................................28<br />

ORB-HT-11001-APO Orbis A1R Heat Detector Standard ...........................26<br />

ORB-HT-11002-APO Orbis A2S Heat Detector Standard ...........................26<br />

ORB-HT-11003-APO Orbis BR Heat Detector Standard ..............................26<br />

ORB-HT-11004-APO Orbis BS Heat Detector Standard ..............................26<br />

ORB-HT-11005-APO Orbis CR Heat Detector Standard ..............................26<br />

ORB-HT-11006-APO Orbis CS Heat Detector Standard ..............................26<br />

ORB-HT-11013-APO Orbis A1R Heat Detector with flashing LED ..........26<br />

ORB-HT-11014-APO Orbis A2S Heat Detector with flashing LED ..........26<br />

ORB-HT-11015-APO Orbis BR Heat Detector with flashing LED .............26<br />

ORB-HT-11016-APO Orbis BS Heat Detector with flashing LED .............26<br />

ORB-HT-11017-APO Orbis CR Heat Detector with flashing LED .............26<br />

ORB-HT-11018-APO Orbis CS Heat Detector with flashing LED ..............26<br />

ORB-HT-11166-APO Orbis A1S Heat Detector ..............................................26<br />

ORB-HT-11167-APO Orbis A1S Heat Detector with flashing LED ..........26<br />

ORB-HT-41001-MAR Orbis Marine A1R Heat Detector ...............................91<br />

ORB-HT-41002-MAR Orbis Marine A2S Heat Detector ...............................91<br />

ORB-HT-41003-MAR Orbis Marine BR Heat Detector ..................................91<br />

ORB-HT-41004-MAR Orbis Marine BS Heat Detector ..................................91<br />

ORB-HT-41005-MAR Orbis Marine CR Heat Detector ..................................91<br />

ORB-HT-41006-MAR Orbis Marine CS Heat Detector ..................................91<br />

ORB-HT-41013-MAR Orbis Marine A1R Heat Detector with<br />

flashing LED ........................................................................91<br />

ORB-HT-41014-MAR Orbis Marine A2S Heat Detector with<br />

flashing LED ........................................................................91<br />

ORB-HT-41015-MAR Orbis Marine BR Heat Detector with<br />

flashing LED ........................................................................91<br />

ORB-HT-41016-MAR Orbis Marine BS Heat Detector with<br />

flashing LED ........................................................................91<br />

ORB-HT-41017-MAR Orbis Marine CR Heat Detector with<br />

flashing LED ........................................................................91<br />

ORB-HT-41018-MAR Orbis Marine CS Heat Detector with<br />

flashing LED ........................................................................91<br />

ORB-HT-51145-APO Orbis IS A1R Heat Detector .........................................99<br />

ORB-HT-51146-APO Orbis IS A1R Heat Detector with flashing LED......99<br />

ORB-HT-51147-APO Orbis IS A2S Heat Detector ..........................................99<br />

ORB-HT-51148-APO Orbis IS A2S Heat Detector with flashing LED ......99<br />

ORB-HT-51149-APO Orbis IS BR Heat Detector ............................................99<br />

ORB-HT-51150-APO Orbis IS BR Heat Detector with flashing LED ........99<br />

ORB-HT-51151-APO Orbis IS BS Heat Detector .............................................99<br />

ORB-HT-51152-APO Orbis IS BS Heat Detector with flashing LED .........99<br />

ORB-HT-51153-APO Orbis IS CR Heat Detector .............................................99<br />

ORB-HT-51154-APO Orbis IS CR Heat Detector with flashing LED .........99<br />

ORB-HT-51155-APO Orbis IS CS Heat Detector .............................................99<br />

ORB-HT-51156-APO Orbis IS CS Heat Detector with flashing LED .........99<br />

ORB-HT-51157-APO Orbis IS A1S Heat Detector ..........................................99<br />

ORB-HT-51158-APO Orbis IS A1S Heat Detector with flashing LED ......99<br />

ORB-MB 50018-APO Orbis IS Timesaver Base ........................................... 100<br />

ORB-MB-00001-APO TimeSaver Base ...............................................................27<br />

ORB-MB-00002-APO TimeSaver LX Base .........................................................27<br />

ORB-MB-00012-APO Orbis LX Base ....................................................................27<br />

ORB-MB-00019-APO TimeSaver Deep Base ...................................................28<br />

ORB-MB-00001-MAR Orbis Marine TimeSaver Base ....................................92<br />

ORB-OH-13001-APO Orbis Multisensor Detector ..........................................26<br />

ORB-OH-13003-APO Orbis Multisensor Detector with<br />

flashing LED ........................................................................26<br />

ORB-OH-43001-MAR Orbis Marine Multisensor Detector ..........................91<br />

ORB-OH-43003-MAR Orbis Marine Multisensor Detector<br />

with flashing LED ............................................................91<br />

ORB-OH-53027-APO Orbis IS Multisensor Detector .....................................99<br />

ORB-OH-53028-APO Orbis IS Multisensor with flashing LED ....................99<br />

ORB-OP-12001-APO Orbis Optical Smoke Detector ....................................26<br />

ORB-OP-12003-APO Orbis Optical Smoke Detector with<br />

flashing LED ........................................................................26<br />

ORB-OP-42001-MAR Orbis Marine Optical Smoke Detector ....................91<br />

ORB-OP-42003-MAR Orbis Marine Optical Smoke Detector<br />

with flashing LED .............................................................91<br />

ORB-OP-52027-APO Orbis IS Optical Smoke Detector ...............................99<br />

ORB-OP-52028-APO Orbis IS Optical Smoke Detector with<br />

flashing LED ........................................................................99<br />

ORB-RB-10004-APO TimeSaver Relay Base ...................................................27<br />

ORB-RB-40004-MAR Orbis Marine Relay Base...............................................92<br />

ORB-SW-10005-APO Sav-Wire Base ..................................................................29<br />

XPA-CB-11170-APO XPander A1R Heat Detector and Mounting Base..42<br />

XPA-CB-11171-APO XPander CS Heat Detector and Mounting Base ..42<br />

XPA-CB-12034-APO XPander Optical Smoke Detector and<br />

Mounting Base .................................................................42<br />

XPA-CB-13032-APO XPander Multisensor Detector and<br />

Mounting Base .................................................................42<br />

XPA-CB-14001-APO XPander Sounder and Sounder Base Red .............89<br />

XPA-CB-14002-APO XPander Sounder and Sounder Base White .........89<br />

XPA-CB-14003-APO XPander Red Sounder Beacon and Red<br />

Sounder Base ....................................................................63<br />

XPA-CB-14004-APO XPander Amber Sounder Beacon and<br />

White Sounder Base .......................................................63<br />

XPA-CB-14005-APO XPander Clear Sounder Beacon and<br />

White Sounder Base .......................................................63<br />

XPA-IN-14007-APO XPander Interface Unit ..................................................43<br />

XPA-MC-14006-APO XPander Manual Call Point ...........................................80<br />

XPA-TE-14010-APO XPander Survey Tool ......................................................43


AlarmSense 35<br />

AlarmSense Alarm Relay ..........................................55000-835 ........................37<br />

AlarmSense A1R Heat Detector (Standard) .......55000-190 ........................36<br />

AlarmSense A1R Heat Detector and<br />

Sounder Base..................................................................55000-196 ........................36<br />

AlarmSense A1R Heat Detector and<br />

Sounder Beacon Base .................................................55000-198 ........................36<br />

AlarmSense Base ..........................................................45681-244 ........................37<br />

AlarmSense CS Heat Detector (High Temp) ......55000-193 ........................36<br />

AlarmSense CS Heat Detector and<br />

Sounder Base..................................................................55000-197 ........................36<br />

AlarmSense CS Heat Detector and<br />

Sounder Beacon Base .................................................55000-199 ........................36<br />

AlarmSense Integrating Optical<br />

Smoke Detector ............................................................55000-391 ........................36<br />

AlarmSense Integrating Optical<br />

Smoke Detector and Sounder Base ......................55000-393 ........................36<br />

AlarmSense Integrating Optical<br />

Smoke Detector and Sounder Beacon Base ......55000-395 ........................36<br />

AlarmSense Manual Call Point (Flush) ..................55000-893 ........................80<br />

AlarmSense Manual Call Point (Surface) .............55000-894 ........................80<br />

AlarmSense Optical Smoke Detector ...................55000-390 ........................36<br />

AlarmSense Optical Smoke Detector<br />

and Sounder Base .........................................................55000-392 ........................36<br />

AlarmSense Optical Smoke Detector<br />

and Sounder Beacon Base ........................................55000-394 ........................36<br />

AlarmSense Red Cap ...................................................45681-295 ................ 57, 65<br />

AlarmSense Sounder Base ........................................45681-510 ........................57<br />

AlarmSense Sounder Base LR ................................45681-341 ........................57<br />

AlarmSense Sounder Beacon Base ......................45681-509 ........................65<br />

AlarmSense Sounder Beacon Base LR .................45681-340 ........................65<br />

AlarmSense White Cap ...............................................45681-294 ................ 57, 65<br />

AV Accessories 66<br />

Beacon Enclosure ..........................................................29600-318 ........................67<br />

Magnetic Wand .............................................................29650-001 ........................67<br />

Base Sounders 55<br />

AlarmSense Sounder Base ........................................45681-510 ........................57<br />

AlarmSense Sounder Base LR ................................45681-341 ........................57<br />

Ancillary Base Sounder ...............................................45681-276 ........................56<br />

Integrated Base Sounder ...........................................45681-278 ........................56<br />

Integrated Base Sounder - Slow Whoop .............45681-291 ........................56<br />

Integrated Base Sounder - Slow Whoop<br />

with Isolator ....................................................................45681-290 ........................56<br />

Integrated Base Sounder DIN-tone<br />

with Isolator ....................................................................45681-300 ........................56<br />

Integrated Base Sounder with Isolator .................45681-277 ........................56<br />

Intelligent Base Sounder ...........................................45681-265 ........................56<br />

Intelligent Base Sounder for Isolating Base ........45681-266 ........................56<br />

Intelligent Base Sounder Slow Whoop ................45681-267 ........................56<br />

Intelligent Base Sounder Slow Whoop<br />

for Isolating Base ...........................................................45681-268 ........................56<br />

Red Cap (for Intelligent Base Sounder) ................29600-257 ........................56<br />

Red Cap (for Integrated Base Sounder) ...............45681-293 ........................56<br />

Series 65 Sounder Base ...........................................45681-512 ........................57<br />

Index<br />

Product<br />

Index: Product 133<br />

Series 65 Sounder Base with Diode ......................45681-513 ........................57<br />

White Cap (for Intelligent Base Sounder) ............26900-256 ........................56<br />

White Cap (for Integrated Base Sounder) ...........45681-292 ........................56<br />

Beacon Bases 60<br />

Loop-Powered Beacon Base with Isolator .........45681-333 ........................61<br />

Loop-Powered Beacon Base ....................................45681-335 ........................61<br />

Loop-Powered Beacon Base with<br />

Australian Flash ..............................................................45681-337 ........................61<br />

Red Cap .............................................................................45681-293 ........................61<br />

White Cap .........................................................................45681-292 ........................61<br />

Beacons 58<br />

Beacon Enclosure ..........................................................29600-318 ........................59<br />

Intelligent Open-Area Beacon Red Lens ..................55000-009 ........................59<br />

Intelligent Open-Area Beacon Clear Lens ..................55000-010 ........................59<br />

Loop-Powered Beacon Amber ...............................55000-879 ........................59<br />

Loop-Powered Beacon Clear Lens Red Flash ....55000-878 ........................59<br />

Loop-Powered Beacon Red ......................................55000-877 ........................59<br />

DIN-Rail Interfaces 75<br />

DIN-Rail Dual Isolator ...................................................55000-802 ........................77<br />

DIN-Rail Input/Output Unit.........................................55000-803 ........................76<br />

DIN-Rail Interface Enclosure (10 units) .................29600-240 ................ 77, 85<br />

DIN-Rail Interface Enclosure (4 units)....................29600-239 ................ 77, 85<br />

DIN-Rail Mains Input/Output Unit ...........................55000-797 ........................76<br />

DIN-Rail Output Unit .....................................................55000-804 ........................76<br />

DIN-Rail Sounder Controller (5 Amperes) ...........55000-182 ........................76


134<br />

Index: Product<br />

DIN-Rail Switch Monitor .............................................55000-822 ........................76<br />

DIN-Rail Switch Monitor Plus ....................................55000-821 ........................77<br />

DIN-Rail Zone Monitor with Isolator.......................55000-812 ........................77<br />

Mini Switch Monitor .....................................................55000-760 ........................77<br />

Discovery 9<br />

Discovery Carbon Monoxide <strong>Fire</strong> Detector .........58000-300 ........................10<br />

Discovery Heat Detector ............................................58000-400 ........................10<br />

Discovery Ionisation Smoke Detector ...................58000-500 ........................10<br />

Discovery Manual Call Point (non standard)<br />

White..................................................................................51800-920 ........................79<br />

Discovery Manual Call Point<br />

(non standard) Yellow ................................................51800-927 ........................79<br />

Discovery Manual Call Point<br />

(non standard) Blue .....................................................58100-928 ........................79<br />

Discovery Manual Call Point<br />

(non standard) Green..................................................58100-929 ........................79<br />

Discovery Manual Call Point - Red (Surface) ......58100-910 ........................79<br />

Discovery Manual Call Point with Isolator -<br />

Red (Surface) ..................................................................58100-908 ........................79<br />

Discovery Multisensor Detector ..............................58000-700 ........................10<br />

Discovery Optical Smoke Detector ........................58000-600 ........................10<br />

Discovery Programmer ..............................................53832-030 ..................... 117<br />

Discovery Sounder Beacon Base ............................45681-393 ........................65<br />

Intelligent Deep Base ..................................................45681-209 ........................11<br />

Isolator ...............................................................................55000-720 ........................11<br />

Intelligent Mounting Base ..........................................45681-210 ........................11<br />

Isolating Base ..................................................................45681-284 ........................11<br />

MiniDisc Remote Indicator.........................................53830-070 ........................12<br />

Discovery Marine 87<br />

Discovery Marine Heat Detector ............................58000-400MAR ..............88<br />

Discovery Marine Ionisation Smoke Detector ...58000-500MAR ..............88<br />

Discovery Marine Isolator ..........................................55000-700MAR ..............88<br />

Discovery Marine Isolator Base ...............................45681-211MAR ..............89<br />

Discovery Marine Manual Call Point .....................58100-970MAR ..............89<br />

Discovery Marine Mounting Base ..........................45681-210MAR ..............89<br />

Discovery Marine Multisensor .................................58000-700MAR ..............88<br />

Discovery Marine Optical Smoke Detector .........58000-600MAR ..............88<br />

Discovery UL 112<br />

Discovery UL Heat Detector ....................................58000-450 ..................... 113<br />

Discovery UL Ionization Smoke Detector ............58000-550 ..................... 113<br />

Discovery UL Multisensor Detector ........................58000-750 ..................... 113<br />

Discovery UL Photo-Electric Smoke Detector ....58000-650 ..................... 113<br />

XP95A Isolating Base ...................................................45681-321USA ............. 114<br />

XP95A 4” Mounting Base ..........................................45681-210USA ............. 114<br />

XP95A 6” Mounting Base ..........................................45681-225USA ............. 114<br />

XP95A E-Z Fit Base .......................................................45681-250 ..................... 114<br />

XP95A Isolator ...............................................................55000-750 ..................... 114<br />

XP95A Isolator Base .....................................................45681-211USA ............. 114<br />

Manual Call Points 78<br />

AlarmSense Manual Call Point (Flush) ..................55000-893 ........................80<br />

AlarmSense Manual Call Point (Surface) .............55000-894 ........................80<br />

Discovery Manual Call Point - Red (Surface) ......58100-910 ........................79<br />

Discovery Manual Call Point with Isolator -<br />

Red (Surface) ..................................................................58100-908 ........................79<br />

Transparent Hinged Cover for Manual<br />

Call Point ...........................................................................26729-152 ........................79<br />

Waterproof Manual Call Point - Red ......................58100-950 ........................80<br />

Waterproof Manual Call Point with<br />

Isolator - Red ...................................................................58100-951 ........................80<br />

XP95 Manual Call Point - Red (Surface) ...............55100-905 ........................79<br />

XP95 Manual Call Point with Isolator -<br />

Red (Surface) ..................................................................55100-908 ........................79<br />

XPander Manual Call Point ........................................XPA-MC-14006-APO .....80<br />

Mini Interfaces 73<br />

Mini Switch Monitor .....................................................55000-760 ........................74<br />

XP95 Mini Switch Monitor with fly leads ............55000-833 ........................74<br />

XP95 Mini Switch Monitor with fly leads<br />

(Interrupt) .........................................................................55000-832 ........................74<br />

Mounting Accessories 82<br />

1.5mm Hexagonal Driver ..........................................29600-095 ........................85<br />

Backplate ..........................................................................45681-233 ........................83<br />

Beacon Enclosure ..........................................................29600-318 ........................84<br />

Conduit Box .....................................................................45681-204 ........................83<br />

Deckhead Adaptor PG16-M20 ................................27249-005 ........................84<br />

Detector Ceiling Tile Mounting Box .......................45681-309 ........................84<br />

DIN-Rail Interface Enclosure (10 units) .................29600-240 ........................85<br />

DIN-Rail Interface Enclosure (4 units)....................29600-239 ........................85<br />

Metal Deckhead Mounting Box (M20) ................29600-139 ........................84<br />

Metal Deckhead Mounting Box (PG16) ...............29600-131 ........................84<br />

Module Base ...................................................................38531-822 ........................83<br />

Polycarbonate Deckhead Mounting Box .............45681-217 ........................84<br />

Series 65 to Orbis Base Adaptor .............................ORB-BA-10008-APO .....85<br />

Series 90 to XP95 Base Adaptor .............................45681-238 ........................85<br />

Series 65 Base Cover .................................................45681-370 ........................83<br />

Sounder Ceiling Plate ...................................................45681-311 ........................83<br />

Sounder Ceiling Tile Mounting Box ........................45681-310 ........................87<br />

XP95 Base Cover .........................................................45681-380 ........................83<br />

Orbis 25<br />

MiniDisc Remote Indicator.........................................53832-070 ........................28<br />

Orbis A1R Heat Detector ............................................ORB-HT-11001-APO ......26<br />

Orbis A1R Heat Detector with flashing LED ........ORB-HT-11013-APO ......26<br />

Orbis A1S Heat Detector ............................................ORB-HT-11166-APO ......26<br />

Orbis A1S Heat Detector with flashing LED ........ORB-HT-11167-APO ......26<br />

Orbis A2S Heat Detector ............................................ORB-HT-11002-APO ......26<br />

Orbis A2S Heat Detector with flashing LED ........ORB-HT-11014-APO ......26<br />

Orbis BR Heat Detector ...............................................ORB-HT-11003-APO ......26<br />

Orbis BR Heat Detector with flashing LED ...........ORB-HT-11015-APO ......26<br />

Orbis BS Heat Detector ...............................................ORB-HT-11004-APO ......26<br />

Orbis BS Heat Detector with flashing LED ...........ORB-HT-11016-APO ......26<br />

Orbis CR Heat Detector ...............................................ORB-HT-11005-APO ......26<br />

Orbis CR Heat Detector with flashing LED ...........ORB-HT-11017-APO ......26<br />

Orbis CS Heat Detector ...............................................ORB-HT-11006-APO ......26<br />

Orbis CS Heat Detector with flashing LED ...........ORB-HT-11018-APO ......26


Orbis LX Base ..................................................................ORB-MB-00012-APO ....27<br />

Orbis Duct Detector ......................................................53546-023 ........................51<br />

Orbis Heater Base .........................................................ORB-HB-00020-APO .....28<br />

Orbis Multisensor Detector .......................................ORB-OH-13001-APO .....26<br />

Orbis Multisensor Detector with<br />

flashing LED .....................................................................ORB-OH-13003-APO .....26<br />

Orbis Optical Smoke Detector ..................................ORB-OP-12001-APO .....26<br />

Orbis Optical Smoke Detector with<br />

flashing LED .....................................................................ORB-OP-12003-APO .....26<br />

TimeSaver Base .............................................................ORB-MB-00001-APO ....27<br />

TimeSaver Deep Base .................................................ORB-MB-00019-APO ....28<br />

TimeSaver Diode Base ................................................ORB-DB-00003-APO .....27<br />

TimeSaver LX Base .......................................................ORB-MB-00002-APO ....27<br />

TimeSaver Relay Base ................................................ORB-RB-10004-APO ......27<br />

Sav-Wire Base ................................................................ORB-SW-10005-APO ....28<br />

Polycarbonate Deckhead Mounting Box .............45681-217 ........................84<br />

Waterproof Base Cover ..............................................45681-519 ........................28<br />

Orbis IS 98<br />

Galvanic Barrier ..............................................................29600-378 ..................... 100<br />

Orbis IS A1R Heat Detector .......................................ORB-HT-51145-APO ......99<br />

Orbis IS A1R Heat Detector with flashing LED .....ORB-HT-51146-APO ......99<br />

Orbis IS A1S Heat Detector .......................................ORB-HT-51157-APO ......99<br />

Orbis IS A1S Heat Detector with flashing LED ......ORB-HT-51158-APO .......99<br />

Orbis IS A2S Heat Detector ...........................................ORB-HT-51147-APO .......99<br />

Orbis IS A2S Heat Detector with flashing LED ......ORB-HT-51148-APO .......99<br />

Orbis IS Adaptor .................................................................ORB-BA-50008-APO ...100<br />

Orbis IS BR Heat Detector ..............................................ORB-HT-51149-APO .......99<br />

Orbis IS BR Heat Detector with flashing LED .........ORB-HT-51150-APO .......99<br />

Orbis IS BS Heat Detector ..............................................ORB-HT-51151-APO .......99<br />

Orbis IS BS Heat Detector with flashing LED .........ORB-HT-51152-APO .......99<br />

Orbis IS CR Heat Detector ..............................................ORB-HT-51153-APO .......99<br />

Orbis IS CR Heat Detector with flashing LED .........ORB-HT-51154-APO .......99<br />

Orbis IS CS Heat Detector ..............................................ORB-HT-51155-APO .......99<br />

Orbis IS CS Heat Detector with flashing LED .........ORB-HT-51156-APO .......99<br />

Orbis IS Multisensor Detector ...................................ORB-OH-53027-APO .....99<br />

Orbis IS Multisensor with flashing LED ..................ORB-OH-53028-APO .....99<br />

Orbis IS Optical Smoke Detector .............................ORB-OP-52027-APO .....99<br />

Orbis IS Optical Smoke Detector with<br />

flashing LED .....................................................................ORB-OP-52028-APO .....99<br />

Orbis IS Timesaver IS Base .......................................ORB-MB-50018-APO .100<br />

Orbis Marine 90<br />

Orbis Marine A1R Heat Detector ............................ORB-HT-41001-MAR .....91<br />

Orbis Marine A1R Heat Detector with<br />

flashing LED .....................................................................ORB-HT-41013-MAR .....91<br />

Orbis Marine A2S Heat Detector ............................ORB-HT-41002-MAR .....91<br />

Orbis Marine A2S Heat Detector with<br />

flashing LED .....................................................................ORB-HT-41014-MAR .....91<br />

Orbis Marine BR Heat Detector ...............................ORB-HT-41003-MAR .....91<br />

Orbis Marine BR Heat Detector with<br />

flashing LED .....................................................................ORB-HT-41015-MAR .....91<br />

Orbis Marine BS Heat Detector ...............................ORB-HT-41004-MAR .....91<br />

Orbis Marine BS Heat Detector with<br />

flashing LED .....................................................................ORB-HT-41016-MAR .....91<br />

Index: Product 135<br />

Orbis Marine CR Heat Detector ...............................ORB-HT-41005-MAR .....91<br />

Orbis Marine CR Heat Detector with<br />

flashing LED .....................................................................ORB-HT-41017-MAR .....91<br />

Orbis Marine CS Heat Detector ................................ORB-HT-41006-MAR .....91<br />

Orbis Marine CS Heat Detector with<br />

flashing LED .....................................................................ORB-HT-41018-MAR .....91<br />

Orbis Marine Multisensor Detector ........................ORB-OH-43001-MAR ....91<br />

Orbis Marine Optical Smoke Detector ..................ORB-OP-42001-MAR ....91<br />

Orbis Marine Relay Base ............................................ORB-RB-40004-MAR .....92<br />

Orbis Marine TimeSaver Base ..................................ORB-MB-00001-MAR ...92<br />

Orbis Marine Multisensor Detector with<br />

flashing LED .....................................................................ORB-OH-43003-MAR ....91<br />

Orbis Marine Optical Smoke Detector<br />

with flashing LED ...........................................................ORB-OP-42003-MAR ....91<br />

Series 65A 108<br />

Series 65A 135˚F Heat Detector flashing LED ......55000-139 ..................... 109<br />

Series 65A 135˚F Heat Detector flashing LED<br />

and magnetic test switch ..........................................55000-138 ..................... 109<br />

Series 65A 135˚F Heat Detector Standard ..........55000-140 ..................... 109<br />

Series 65A 170˚F Heat Detector flashing LED ......55000-142 ..................... 109<br />

Series 65A 170˚F Heat Detector flashing LED<br />

and magnetic test switch ..........................................55000-141 ..................... 109<br />

Series 65A 170˚F Heat Detector Standard ..........55000-143 ..................... 109<br />

Series 65A 200˚F Heat Detector flashing LED ......55000-145 ..................... 109<br />

Series 65A 200˚F Heat Detector flashing LED<br />

and magnetic test switch ..........................................55000-144 ..................... 109<br />

Series 65A 200˚F Heat Detector Standard ..........55000-146 ..................... 109<br />

Series 65A 4” 12V End-of-Line Relay Base .........45681-257 ..................... 110<br />

Series 65A 4” 24V End-of-Line Relay Base .........45681-258 ..................... 110<br />

Series 65A 4” Auxiliary Relay Base ........................45681-256 ..................... 110<br />

Series 65A 4” Standard Base ...................................45681-200USA ............. 110<br />

Series 65A 4” Standard Relay Base .......................45681-255 ..................... 110<br />

Series 65A 6” E-Z Fit Base .........................................45681-251 ..................... 111<br />

Series 65A 6” Low Profile Base ...............................45681-232 ..................... 110<br />

Series 65A 6” Standard Base ...................................45681-220USA ............. 110<br />

Series 65A Ionization Smoke Detector<br />

flashing LED ...................................................................55000-226 ..................... 109<br />

Series 65A Ionization Smoke Detector<br />

flashing LED and magnetic test switch ................55000-225 ..................... 109<br />

Series 65A Ionization Smoke Detector<br />

Standard ...........................................................................55000-227 ..................... 109<br />

Series 65A Photo-Electric Smoke Detector<br />

flashing LED ...................................................................55000-326 ..................... 109<br />

Series 65A Photo-Electric Smoke Detector<br />

flashing LED and magnetic test switch ................55000-325 ..................... 109<br />

Series 65A Photo-Electric Smoke Detector<br />

Standard ...........................................................................55000-327 ..................... 109<br />

Series 65 29<br />

MiniDisc Remote Indicator.........................................53832-070 ........................33<br />

Series 65 12V Relay Base ..........................................45681-508 ........................31<br />

Series 65 Auxiliary Relay Base ...............................45681-246 ........................31<br />

Series 65 Base Cover .................................................45681-370 ........................83<br />

Series 65 Diode Base ...................................................45681-201 ........................31


136<br />

Index: Product<br />

Series 65 End-of-Line Relay Base (12V) ..............45681-247 ........................32<br />

Series 65 End-of-Line Relay Base (24V) ..............45681-248 ........................32<br />

Series 65 Sav-Wire Base ............................................45681-206 ........................32<br />

Series 65 Standard Base ............................................45681-200 ........................31<br />

Series 65 A1R Heat Detector flashing LED ..........55000-121 ........................31<br />

Series 65 A1R Heat Detector flashing LED<br />

and magnetic test switch ..........................................55000-120 ........................31<br />

Series 65 A1R Heat Detector Standard ................55000-122 ........................31<br />

Series 65 BR Heat Detector flashing LED ..........55000-126 ........................31<br />

Series 65 BR Heat Detector flashing LED<br />

and magnetic test switch ..........................................55000-125 ........................31<br />

Series 65 BR Heat Detector Standard ...................55000-127 ........................31<br />

Series 65 CR Heat Detector flashing LED ..........55000-131 ........................31<br />

Series 65 CR Heat Detector flashing LED<br />

and magnetic test switch ..........................................55000-130 ........................31<br />

Series 65 CR Heat Detector Standard ...................55000-132 ........................31<br />

Series 65 CS Heat Detector flashing LED ...........55000-136 ........................31<br />

Series 65 CS Heat Detector flashing LED<br />

and magnetic test switch ..........................................55000-135 ........................31<br />

Series 65 CS Heat Detector Standard ...................55000-137 ........................31<br />

Series 65 Integrating Ionisation Smoke<br />

Detector ............................................................................55000-220 ........................30<br />

Series 65 Integrating Ionisation Smoke<br />

Detector flashing LED ..................................................55000-219 ........................30<br />

Series 65 Integrating Ionisation Smoke Detector<br />

flashing LED and magnetic test switch .................55000-218 ........................30<br />

Series 65 Ionisation Smoke Detector<br />

flashing LED .....................................................................55000-216 ........................30<br />

Series 65 Ionisation Smoke Detector<br />

flashing LED and magnetic test switch ................55000-215 ........................30<br />

Series 65 Ionisation Smoke Detector<br />

Standard ...........................................................................55000-217 ........................30<br />

Series 65 Optical Smoke Detector<br />

flashing LED ...................................................................55000-316 ........................30<br />

Series 65 Optical Smoke Detector<br />

flashing LED and magnetic test switch ................55000-315 ........................30<br />

Series 65 Optical Smoke Detector Standard ......55000-317 ........................30<br />

Series 65 Sounder Base ..............................................45681-512 ........................57<br />

Series 65 Standard Relay Base ...............................45681-245 ........................32<br />

Sounder Beacon Bases 64<br />

AlarmSense Red Cap ...................................................45681-295 ........................65<br />

AlarmSense Sounder Beacon Base ......................45681-509 ........................65<br />

AlarmSense Sounder Beacon Base LR .................45681-340 ........................65<br />

AlarmSense White Cap ...............................................45681-294 ........................65<br />

Discovery Sounder Beacon Base ............................45681-393 ........................65<br />

Red Cap .............................................................................45681-293 ........................65<br />

Sounder Beacon Base ..............................................45681-331 ........................65<br />

Sounder Beacon Base Slow Whoop<br />

with Isolator ....................................................................45681-332 ........................65<br />

Sounder Beacon Base with Australian Tone ......45681-336 ........................65<br />

Sounder Beacon Base with Isolator .......................45681-330 ........................65<br />

Sounder Beacon Base with Isolator DIN-Tone ....45681-334 ........................65<br />

Sounder Beacon Base with NZ Tone ....................45681-338 ........................65<br />

White Cap .........................................................................45681-292 ........................65<br />

Sounder Beacons 62<br />

Intelligent Open-Area Sounder Beacon<br />

Clear Lens (Sonos) ........................................................55000-006 ........................63<br />

Intelligent Open-Area Sounder Beacon<br />

Red Lens (Sonos) ..........................................................55000-005 ........................63<br />

Multi-Tone Open Area Sounder Beacon Red.....55000-291 ........................63<br />

Multi-Tone Open Area Sounder Beacon Red<br />

with Isolator ....................................................................55000-293 ........................63<br />

Multi-Tone Open Area Sounder Beacon White ..55000-292 ........................63<br />

Multi-Tone Open Area Sounder Beacon White<br />

with Isolator ....................................................................55000-294 ........................63<br />

Weatherproof Multi-Tone Open Area<br />

Sounder Beacon Red ...................................................55000-296 ........................63<br />

Weatherproof Multi-Tone Open Area<br />

Sounder Beacon Red with Isolator .........................55000-298 ........................63<br />

Weatherproof Multi-Tone Open Area<br />

Sounder Beacon White ...............................................55000-297 ........................63<br />

Weatherproof Multi-Tone Open Area<br />

Sounder Beacon White with Isolator ....................55000-299 ........................63<br />

XPander Amber Sounder Beacon and<br />

White Sounder Base ....................................................XPA-CB-14004-APO ......63<br />

XPander Clear Sounder Beacon and<br />

White Sounder Base ....................................................XPA-CB-14005-APO ......63<br />

XPander Red Sounder Beacon and<br />

Red Sounder Base ........................................................XPA-CB-14003-APO ......63<br />

Sounders 53<br />

Intelligent 100dB(A) Open-Area Sounder Red..55000-278 ........................54<br />

Intelligent 100dB(A) Open-Area Sounder<br />

Slow Whoop Red ..........................................................55000-276 ........................54<br />

Intelligent 100dB(A) Open-Area Sounder<br />

Slow Whoop White ......................................................55000-277 ........................54<br />

Intelligent 100dB(A) Open-Area Sounder<br />

White..................................................................................55000-279 ........................54<br />

Intelligent 100dB(A) Open-Area<br />

Weatherproof Sounder Red ......................................55000-274 ........................54<br />

Intelligent 100dB(A) Open-Area<br />

Weatherproof Sounder White ..................................55000-275 ........................54<br />

Intelligent Open-Area Sounder Red (Sonos)......55000-001 ........................54<br />

Intelligent Open-Area Sounder White (Sonos) ...55000-002 ........................54<br />

XPander Sounder and Sounder Base Red ...........XPA-CB-14001-APO ......54<br />

XPander Sounder and Sounder Base White .......XPA-CB-14002-APO ......54<br />

Specialist 44<br />

Base Mounted Flame Detector Bracket...............29600-458 ........................47<br />

Conventional Duct Smoke Detector ......................53546-021 ........................51<br />

<strong>Fire</strong>beam Adaptor Plate .............................................29600-353 ........................49<br />

<strong>Fire</strong>beam Beam Detector 5-40m ...........................29600-350 ........................49<br />

<strong>Fire</strong>beam Extension Kit 40-80m .............................29600-351 ........................49<br />

<strong>Fire</strong>beam Extension Kit 80-100m ...........................29600-352 ........................49<br />

Flame Detector Bracket ..............................................29600-203 ........................46<br />

Flame Detector Weathershield................................29600-206 ........................46<br />

Intelligent Base Mounted UV IR² Flame<br />

Detector ...........................................................................55000-023 ........................47<br />

Intelligent Base Mounted UV Flame Detector ...55000-022 ........................47<br />

Intelligent Base Mounted IR3 Flame<br />

Detector ............................................................................55000-024 ........................47


Intelligent Duct Detector ............................................53546-022 ........................51<br />

Intelligent Flameproof IR² Flame Detector ..........55000-295 ........................46<br />

Intelligent Flameproof IR³ Flame Detector ..........55000-021 ........................46<br />

Intelligent IR² Flame Detector ..................................55000-280 ........................46<br />

Intelligent IR 3 Flame Detector ..................................55000-020 ........................46<br />

Orbis Duct Detector ......................................................53546-023 ........................51<br />

Reflective Beam Detector (50-100m) .................55000-273 ........................49<br />

Reflective Beam Detector (5-50m).......................55000-268 ........................49<br />

Reflective Beam Detector Backbox .......................29600-241 ........................49<br />

Standard Interfaces 69<br />

Input/Output Unit ..........................................................55000-847 ........................70<br />

Mains Switching Input/Output Unit .......................55000-875 ........................71<br />

Output Unit ......................................................................55000-849 ........................70<br />

Sounder Control Unit ....................................................55000-852 ........................70<br />

Switch Monitor Plus .....................................................55000-841 ........................71<br />

Switch Monitor ...............................................................55000-843 ........................71<br />

Three Channel Input/Output Unit ...........................55000-588 ........................70<br />

Three Channel Input/Output Unit PCB only ........43781-588 ........................70<br />

Zone Monitor Unit .........................................................55000-845 ........................71<br />

Test Equipment and Maintenance 116<br />

1.5mm Hexagonal Driver (locks detectors<br />

to bases) .........................................................................29600-095 .................... 118<br />

Aerosol Test Gas ..........................................................29600-225 .................... 118<br />

Battery Batons ..............................................................29600-183 .................... 118<br />

Battery Charger (No Mains Lead)...........................29600-214 .................... 118<br />

Conventional Test Set .................................................53832-020 ..................... 117<br />

Cordless Heat Detector Tester ................................29600-213 .................... 118<br />

Cordless Heat Tester Kit ............................................29600-212 .................... 118<br />

CO Test Gas .....................................................................29600-235 ..................... 114<br />

Detector Extract Tool ..................................................29600-102 .................... 118<br />

Discovery Programmer ..............................................53832-030 ..................... 117<br />

Extension Pole, 1.13m ...............................................29600-103 .................... 118<br />

Flame Sensor Test Unit and Case ...........................29600-226 ..................... 117<br />

Heat Detector Test Pole (110V) .............................29600-110 .................... 118<br />

Heat Detector Test Pole (240V) ..............................29600-101 .................... 118<br />

Printer for XP95 Test Set ............................................55000-872 ..................... 117<br />

Smoke Dispenser Head ............................................29600-100 .................... 118<br />

Telescopic Pole, 1.26m to 4.5m ............................29600-104 .................... 118<br />

Detector Duster .............................................................29600-449 ..................... 118<br />

Smoke/Heat Unit ..........................................................29600-459 ..................... 118<br />

Smoke/Heat Kit .............................................................29600-460 ..................... 118<br />

Smoke/Heat/CO Unit ..................................................29600-461 ..................... 118<br />

Smoke/Heat/CO Kit .....................................................29600-462 ..................... 118<br />

6-Pack Replacement Smoke Capsule ...................29600-463 ..................... 118<br />

3-Pack Replacement Smoke Capsule ...................29600-464 ..................... 118<br />

6-Pack Replacement CO Capsule ...........................29600-465 ..................... 118<br />

3-Pack Replacement CO Capsule ...........................29600-466 ..................... 118<br />

UK Mains Lead ..............................................................29600-215 .................... 118<br />

XP95 Test Set .................................................................55000-870 ..................... 117<br />

XPERT Card Insertion Tool .........................................45681-235 .................... 118<br />

Index: Product 137<br />

XP95 16<br />

Intelligent Deep Base ..................................................45681-209 ........................19<br />

Intelligent Mounting Base ..........................................45681-210 ........................18<br />

Isolator ...............................................................................55000-720 ........................18<br />

Isolator Base ....................................................................45681-211 ........................18<br />

Low Power Relay Base ...............................................45681-242 ........................19<br />

New Isolating Base ......................................................45681-284 ........................18<br />

MiniDisc Remote Indicator.........................................53832-070 ........................19<br />

Polycarbonate Deckhead Mounting Box .............29600-196 ........................19<br />

Printer for XP95 Test Set ............................................55000-872 ..................... 117<br />

Waterproof Base Cover ..............................................45681-519 ........................19<br />

XP95 Base Cover .........................................................45681-380 ........................83<br />

XP95 Heat Detector High Temperature ...............55000-401 ........................17<br />

XP95 Heat Detector Standard ..................................55000-400 ........................17<br />

XP95 Heater Base .........................................................45681-219 ........................19<br />

XP95 Ionisation Smoke Detector ............................55000-500 ........................17<br />

XP95 Manual Call Point - Red (Surface) ...............55100-905 ........................79<br />

XP95 Manual Call Point with Isolator -<br />

Red (Surface) ..................................................................55100-908 ........................79<br />

XP95 Multisensor Detector .......................................55000-885 ........................17<br />

XP95 Optical Smoke Detector .................................55000-600 ........................17<br />

XP95 Test Set .................................................................55000-870 ..................... 117<br />

XP95A 103<br />

XP95A Isolating Base ...................................................45681-321USA ............. 105<br />

XP95A 4” Low Power Relay Base ..........................45681-242USA ............. 106<br />

XP95A 4” Mounting Base ..........................................45681-210USA ............. 105<br />

XP95A 6” Mounting Base ..........................................45681-225USA ............. 105<br />

XP95A Dual Priority Switch Monitor Module .....55000-790 ..................... 107<br />

XP95A E-Z Fit Base .......................................................45681-250 ..................... 104<br />

XP95A Heat Detector ..................................................55000-450 ..................... 104<br />

XP95A Ionization Smoke Detector .........................55000-550 ..................... 104<br />

XP95A Isolator ...............................................................55000-750 ..................... 105<br />

XP95A Isolator Base .....................................................45681-211USA ............. 105<br />

XP95A Loop Powered Beam Detector ................55000-266 .....................104<br />

XP95A Mini Priority Switch Monitor Module ......55000-830 ..................... 106<br />

XP95A Mini Switch Monitor Module .....................55000-831 ..................... 106<br />

XP95A Multisensor Detector ....................................55000-886 ..................... 104<br />

XP95A Photo-Electric Smoke Detector ................55000-650 ..................... 104<br />

XP95A Priority Switch Monitor Module ................55000-806 ..................... 107<br />

XP95A Relay Output Module ...................................55000-863 ..................... 107<br />

XP95A Sounder Control Module .............................55000-825 ..................... 107<br />

XP95A Switch Monitor Input/Output Module ...55000-820 ..................... 107<br />

XP95A Switch Monitor Module ...............................55000-805 ..................... 106<br />

Mini Monitor Module ...................................................55000-765 ..................... 106<br />

XP95 IS 95<br />

IS Galvanic Barrier .........................................................29600-098 ........................97<br />

XP95 IS Heat Detector.................................................55000-440 ........................96<br />

XP95 IS Ionisation Smoke Detector .......................55000-540 ........................96<br />

XP95 IS Manual Call Point MEDC Break<br />

Glass - Black/Yellow Stripes .....................................55000-966 ........................97


138<br />

Index: Product<br />

XP95 IS Manual Call Point MEDC Break<br />

Glass - Blue ......................................................................55000-964 ........................97<br />

XP95 IS Manual Call Point MEDC Break<br />

Glass - Red .......................................................................55000-960 ........................97<br />

XP95 IS Manual Call Point MEDC Break<br />

Glass - Yellow .................................................................55000-962 ........................97<br />

XP95 IS Manual Call Point MEDC Break<br />

Glass with flap - Black/Yellow Stripes ..................55000-967 ........................97<br />

XP95 IS Manual Call Point MEDC Break<br />

Glass with flap - Blue ...................................................55000-965 ........................97<br />

XP95 IS Manual Call Point MEDC Break<br />

Glass with flap - Red ....................................................55000-961 ........................97<br />

XP95 IS Manual Call Point MEDC Break<br />

Glass with flap - Yellow ..............................................55000-963 ........................97<br />

XP95 IS Manual Call Point MEDC Push<br />

Button - Black/Yellow Stripes ..................................55000-973 ........................97<br />

XP95 IS Manual Call Point MEDC Push<br />

Button - Blue ...................................................................55000-972 ........................97<br />

XP95 IS Manual Call Point MEDC Push<br />

Button - Red ....................................................................55000-970 ........................97<br />

XP95 IS Manual Call Point MEDC Push<br />

Button - Yellow ..............................................................55000-971 ........................97<br />

XP95 IS Manual Call Point With Flap -<br />

Blue/White.......................................................................55000-945 ........................97<br />

XP95 IS Manual Call Point Without Flap -<br />

Blue/White.......................................................................55100-944 ........................97<br />

XP95 IS Manual Call Point Without Flap - Red ...55100-940 ........................97<br />

XP95 IS Manual Call Point Without Flap - Yellow 55100-942 ........................97<br />

XP95 IS Mounting Base ..............................................45681-215 ........................97<br />

XP95 IS Optical Smoke Detector .............................55000-640 ........................97<br />

XP95 Protocol Translator (Dual) ..............................55000-856 ........................97<br />

XP95 Protocol Translator (Single) ...........................55000-855 ........................97<br />

XPander 41<br />

XPander A1R Heat Detector and Mounting Base ..XPA-CB-11170-APO ......42<br />

XPander Amber Sounder Beacon and<br />

White Sounder Base ....................................................XPA-CB-14004-APO ......63<br />

XPander Clear Sounder Beacon and<br />

White Sounder Base ....................................................XPA-CB-14005-APO ......63<br />

XPander CS Heat Detector and Mounting Base XPA-CB-11171-APO ......42<br />

XPander Interface Unit ................................................XPA-IN-14007-APO .......43<br />

XPander Manual Call Point ........................................XPA-MC-14006-APO .....80<br />

XPander Multisensor Detector and Mounting<br />

Base ....................................................................................XPA-CB-13032-APO ......42<br />

XPander Optical Smoke Detector and<br />

Mounting Base ...............................................................XPA-CB-12034-APO ......42<br />

XPander Red Sounder Beacon and<br />

Red Sounder Base ........................................................XPA-CB-14003-APO ......63<br />

XPander Sounder and Sounder Base Red ...........XPA-CB-14001-APO ......54<br />

XPander Sounder and Sounder Base White .......XPA-CB-14002-APO ......54<br />

XPander Survey Tool ...................................................XPA-TE-14010-APO .......43<br />

XPERT Cards 22<br />

Blank XPERT Card ..........................................................38531-771 ........................23<br />

Pre-Addressed XPERT Cards .....................................45682-127 ........................23


Apollo Overseas Offices<br />

Apollo America<br />

821 Ulrich Avenue<br />

Louisville<br />

Kentucky<br />

40219<br />

USA<br />

Tel: +1 502 964 6565<br />

Fax: +1 502 964 6229<br />

Email: infoUSA@apollo-fire.com<br />

Web: www.apollo-fire.com<br />

Apollo Germany<br />

Apollo GmbH<br />

Am Anger 31<br />

D-33332 Gütersloh<br />

Germany<br />

Tel: +49 5241 33060<br />

Fax: +49 5241 330629<br />

Email: verkauf@apollo-feuer.de<br />

Web: www.apollo-feuer.de<br />

Apollo Spain<br />

Apollo <strong>Fire</strong> Detectors S.A.<br />

Calle Rio Tietar 12<br />

Nave 6<br />

Pol Ind El Nogal<br />

28110 Algete<br />

Madrid<br />

Spain<br />

Tel: +34 9162 89209<br />

Fax: +34 9162 90168<br />

Email: información@apollo-fire.com<br />

Web: www.apollo-fire.es<br />

Apollo Ireland<br />

Apollo Ireland<br />

8 Willbrook Road<br />

Rathfarnham<br />

Dublin 14<br />

Republic of Ireland<br />

Tel: +353 1 493 3896<br />

Email: info-ireland@apollo-fire.co.uk<br />

Web: www.apollo-fire.ie<br />

Apollo China<br />

Apollo China<br />

24D Huamin Empire Plaza<br />

726 Yan An Road (W)<br />

Shanghai<br />

200050<br />

The People’s Republic of China<br />

Tel: +86 21 5237 0922<br />

Fax: +86 21 5237 0920<br />

Email: info-china@apollo-fire.com<br />

Web: www.apollo-fire.com.cn<br />

© Apollo <strong>Fire</strong> Detectors Ltd 2007-2009<br />

PP2327/2009/Issue 4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!