MUFIO_CT_brochure_2004.doc<br />

University of Miskolc<br />

Research Institute of Applied Chemistry<br />

3515 Miskolc-Egyetemváros, PO Box 2., Hungary<br />

www.akki.hu<br />

<strong>Experimental</strong> <strong>Apparatus</strong> <strong>for</strong> <strong>Flow</strong> <strong>Study</strong> <strong>in</strong> <strong>Rock</strong><br />

X-ray computed tomography (CT) is a well-known method <strong>for</strong> measur<strong>in</strong>g rock properties and<br />

fluid transport behaviour, and the user get some <strong>in</strong><strong>for</strong>mation on capillary end effects and other<br />

saturation gradients <strong>in</strong> core floods. University of Miskolc Research Institute of Applied<br />

Chemistry (Department of Instrumentation and In<strong>for</strong>matic) eng<strong>in</strong>eers have developed the<br />

experimental system <strong>for</strong> non-<strong>in</strong>vasive <strong>in</strong> situ imag<strong>in</strong>g of flow <strong>in</strong> porous medium at reservoir<br />

conditions.<br />

Specification<br />

Cells:<br />

Block diagram of the experimental model system<br />

Cell-1<br />

Cell-2<br />

Cell-3<br />

o Temperature – ambient<br />

o Pressure – max. 10 bar<br />

o Temperature – max. 150 C<br />

o Pressure – max. 450 bar<br />

o Temperature – ambient<br />

o Pressure – vacuum


<strong>Experimental</strong> <strong>Apparatus</strong> <strong>for</strong> <strong>Flow</strong> <strong>Study</strong> <strong>in</strong> <strong>Rock</strong> MEAKKI M_FIO – 2004<br />

Fluid ration<strong>in</strong>g: by programmable high pressure pumps<br />

0,001 – 107 ml/m<strong>in</strong><br />

Gas ration<strong>in</strong>g: by high pressure gas regulator<br />

0,3-15 nl/m<strong>in</strong><br />

Back pressure: regulated by BP regulator<br />

Mantle pressure: automatic controlled<br />

Transducers: pressure transducers<br />

differential pressure transducer<br />

temperature transducers<br />

flow transducer<br />

Data collection: by computer<br />

<strong>Apparatus</strong><br />

Measur<strong>in</strong>g with Cell-2 Measur<strong>in</strong>g with Cell-3