Life safety systems for every applic<strong>at</strong>ion, large or small . . .<br />

SECUTRON provides both conventional <strong>an</strong>d <strong>an</strong>alog addressable control for your life safety<br />

system. Conventional p<strong>an</strong>els r<strong>an</strong>ge from the 2-zone MR-2602 to the 24-zone MR-2900.<br />

Analog addressable control is available in 1 <strong>an</strong>d 2 loop, 4 loop, <strong>an</strong>d networkable multi-loop<br />

systems. Our powerhouse MR-2900 addressable control p<strong>an</strong>el includes integr<strong>at</strong>ed audio<br />

<strong>an</strong>d has networked capacity of more th<strong>an</strong> 800,000 points.<br />

MR-2602/2605 Fire Alarm Control P<strong>an</strong>els<br />

The MR-2602 (2 zone) <strong>an</strong>d MR-2605 (5 zone) are vers<strong>at</strong>ile, power-packed fire alarm control<br />

p<strong>an</strong>els designed for small building fire protection. Both offer <strong>an</strong> exceptional fe<strong>at</strong>ure set, a<br />

power supply th<strong>at</strong> will h<strong>an</strong>dle the p<strong>an</strong>el’s full r<strong>at</strong>ed load, <strong>an</strong>d flexible front p<strong>an</strong>el programming<br />

for quick <strong>an</strong>d simple configur<strong>at</strong>ion to suit the applic<strong>at</strong>ion <strong>at</strong> h<strong>an</strong>d. Powerful, vers<strong>at</strong>ile, <strong>an</strong>d<br />

ideally suited for small, fast turnaround fire applic<strong>at</strong>ions.<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

Two or Five Class B / Style B dual-use<br />

zones<br />

Two Class B / Style Y notific<strong>at</strong>ion appli<strong>an</strong>ce<br />

circuits<br />

4.2A power supply<br />

500mA of aux. power<br />

Common alarm relay; Common trouble relay<br />

Integral b<strong>at</strong>tery charger<br />

MR-2300 Fire Alarm Control P<strong>an</strong>els<br />

The MR-2300 Series fire alarm control p<strong>an</strong>els are multi-zone units designed for maximum<br />

flexibility <strong>an</strong>d easy install<strong>at</strong>ion <strong>an</strong>d oper<strong>at</strong>ion. The MR-2300 Series are available in six <strong>an</strong>d<br />

twelve zone models with a built-in UDACT/Digital Communic<strong>at</strong>or on select models. The<br />

MR-2300 Series are available in LED or LCD display configur<strong>at</strong>ions.<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

‘Secur-Bus’<br />

Event buffer<br />

Six programmable zone options<br />

Class A capability<br />

One-m<strong>an</strong> walk test<br />

Programmable silence timers<br />

Front p<strong>an</strong>el programming<br />

Optional UDACT<br />

MR-2400 Addressable Fire Alarm Control P<strong>an</strong>els<br />

Employing addressable input circuits with addressable <strong>an</strong>alog detectors, <strong>an</strong>d monitoring <strong>an</strong>d<br />

control modules, the MR-2400 is ideally suited to fit the varied needs of residential, commercial,<br />

industrial, <strong>an</strong>d institutional applic<strong>at</strong>ions.<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

Six <strong>an</strong>d Twelve zone configur<strong>at</strong>ions<br />

LED <strong>an</strong>d LCD display configur<strong>at</strong>ions<br />

Powerful 5 Amp dedic<strong>at</strong>ed power supply<br />

Configurable UDACT/Digital Communic<strong>at</strong>or<br />

True Class A circuit configur<strong>at</strong>ion<br />

Remote programming capability<br />

Remote relay modules<br />

UL Central St<strong>at</strong>ion Connection<br />

UL Listed for Releasing Service<br />

CSFM High Rise Listed<br />

Sophistic<strong>at</strong>ed capabilities yet simple to<br />

oper<strong>at</strong>e<br />

Addressable detection circuits<br />

Adjustable sensitivity; Day/night sensitivity<br />

One-person system test capability<br />

Passcode protection<br />

History log ~ 1400 events<br />

System alarm & trouble relays<br />

Remote alarm & trouble <strong>an</strong>nunci<strong>at</strong>ion<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

�<br />

�<br />

Two event history logs<br />

Optional City Tie/Polarity Reversal Modules<br />

Optional modules for internal relay circuits<br />

Built-in sync protocols for major strobe<br />

m<strong>an</strong>ufacturers<br />

Remote upload/download capabilities<br />

Individual circuit disconnect buttons<br />

�<br />

LCD supertwist 80 character (4 x 20) backlit<br />

display<br />

Sprinkler supervision<br />

Ground fault indic<strong>at</strong>ion by supervised circuit<br />

Cross-zoned releasing circuit<br />

Addressable input circuits Style 4 (Class B)<br />

or Style 6 (Class A)<br />

Style Y (Class B) or Style Z (Class A)<br />

notific<strong>at</strong>ion appli<strong>an</strong>ce (bell) circuits<br />

Signal silence inhibit<br />

Signal time limit cut-out<br />

Alarm verific<strong>at</strong>ion by device


S E C U T R O N F I R E A L A R M S Y S T E M S<br />

High rise evacu<strong>at</strong>ion, networking capability<br />

� MV-2700 High Rise Evacu<strong>at</strong>ion System<br />

The MV-2700 High Rise Evacu<strong>at</strong>ion System oper<strong>at</strong>es in conjunction with the Fire<br />

Alarm Control P<strong>an</strong>el (FACP) in a building to provide autom<strong>at</strong>ic response to life safety<br />

emergencies. The MV-2700 includes all necessary fe<strong>at</strong>ures to provide <strong>an</strong> effective<br />

voice evacu<strong>at</strong>ion system. The MV-2700 c<strong>an</strong> be custom configured to s<strong>at</strong>isfy the needs<br />

of <strong>an</strong>y high rise applic<strong>at</strong>ion.<br />

•<br />

•<br />

•<br />

•<br />

True Multiplex 6 Ch<strong>an</strong>nel Distributed<br />

Audio<br />

Integr<strong>at</strong>ed Fire Phone, Area of Rescue<br />

capability<br />

Modular System - components added<br />

as needed<br />

Integr<strong>at</strong>ed 2 Ch<strong>an</strong>nel Digital Message<br />

Repe<strong>at</strong>er<br />

� MR-2900 Addressable Fire Alarm Control P<strong>an</strong>els<br />

The MR-2900, with networking capability, is ideal for residential, commercial, industrial,<br />

<strong>an</strong>d institutional applic<strong>at</strong>ions. The MR-2900 provides both conventional <strong>an</strong>d addressable<br />

input circuits. It has the ability to ‘software’ configure conventional input circuits for alarm<br />

or supervisory function, <strong>an</strong>d oper<strong>at</strong>ion with contact devices only, smoke detectors<br />

only, or both smoke detectors <strong>an</strong>d contact devices with the system having the ability<br />

to differenti<strong>at</strong>e between smoke detector <strong>an</strong>d contact device activ<strong>at</strong>ion.<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

UL, CSFM, & MEA Listed<br />

UL Listed for Networking<br />

UL Listed for Releasing Service<br />

CSFM High Rise Listed<br />

FM Approved<br />

Sophistic<strong>at</strong>ed capabilities yet simple to<br />

oper<strong>at</strong>e<br />

Conventional & addressable detection<br />

circuits<br />

Adjustable day/night sensitivity<br />

One-person system test capability<br />

Field programmable via PC<br />

Passcode protection<br />

History log ~ 1400 events<br />

Alarm, supervisory, & trouble relays<br />

Custom labels per zone<br />

Live Microphone Page to <strong>an</strong>y zone<br />

Fast RS-485 Communic<strong>at</strong>ion<br />

Protocol<br />

Fully Supervised<br />

Easy Install<strong>at</strong>ion <strong>an</strong>d Oper<strong>at</strong>ion<br />

N<strong>at</strong>ural Sound Voice Recordings<br />

Built in Alarm <strong>an</strong>d Alert Signals<br />

Up to 4 Minute Message Capacity<br />

� MR-2100/2200 Addressable Fire Alarm P<strong>an</strong>els<br />

The MR-2100/MR-2200 Fire Alarm Control P<strong>an</strong>els provide flexible <strong>an</strong>d cost effective<br />

oper<strong>at</strong>ion to s<strong>at</strong>isfy system requirements for both economy <strong>an</strong>d capability. These<br />

intelligent fire alarm systems are available in single <strong>an</strong>d dual loop configur<strong>at</strong>ions <strong>an</strong>d<br />

c<strong>an</strong> provide peer-to-peer networking of up to 254 nodes.<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

UL, ULC, CSFM <strong>an</strong>d MEA Listed<br />

One or Two SLC/Loop Intelligent Fire<br />

Alarm Control P<strong>an</strong>el (FACP)<br />

198 addressable devices per SLC<br />

SLCs are selectable for either Class A<br />

(Style 6) or Class B (Style 4) oper<strong>at</strong>ion<br />

Modular design<br />

LCD &/or LED <strong>an</strong>nunci<strong>at</strong>ors<br />

User friendly oper<strong>at</strong>ion<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

Remote alarm & trouble <strong>an</strong>nunci<strong>at</strong>ion<br />

LCD supertwist 80 character (4 x 20)<br />

backlit display<br />

Sprinkler supervision<br />

Cross-zoned releasing circuit<br />

Software definable conventional input<br />

circuits<br />

Conventional input circuits Style B<br />

(Class B) or Style D (Class A)<br />

Addressable input circuits Style 4 (Class<br />

B) or Style 6 (Class A)<br />

Input circuits programmable for N.O. or<br />

N.C. contacts<br />

‘Hot Key’ system controls<br />

Alarm verific<strong>at</strong>ion by zone or device<br />

History log ~ 1000 events<br />

Removable terminal blocks for easy<br />

wiring<br />

Programmable cross-zoning functions,<br />

day/night mode, <strong>an</strong>d selective control<br />

oper<strong>at</strong>ions<br />

Cabinet doors are removable for easy<br />

install<strong>at</strong>ion<br />

Windows based programming software


Office Buildings Hospitals Hotels Schools Cultural Centers<br />

World-wide reput<strong>at</strong>ion<br />

From one side of the globe to the other, SECUTRON fire<br />

alarm systems provide a safe <strong>an</strong>d secure environment<br />

in a wide r<strong>an</strong>ge of building applic<strong>at</strong>ions.<br />

SECUTRON’s intern<strong>at</strong>ional reput<strong>at</strong>ion for reliability has<br />

made our equipment the systems of choice for numerous<br />

schools, hospitals, hotels <strong>an</strong>d office towers.<br />

� Davenport Community School District, Iowa<br />

The wide r<strong>an</strong>ge of building ages <strong>an</strong>d styles among the Davenport School District’s<br />

facilities presented particular challenges to the MR-2900 – each of which was met with<br />

a solution th<strong>at</strong> only a system this flexible <strong>an</strong>d cost-effective could deliver.<br />

Number of Points Monitored: 50 per school — Over 2,000 total for school district.<br />

� Aga Kh<strong>an</strong> University Hospital, Karachi, Pakist<strong>an</strong><br />

With over 28,000 in-p<strong>at</strong>ients <strong>an</strong>d more th<strong>an</strong> a quarter million out-p<strong>at</strong>ients <strong>an</strong>nually,<br />

Pakist<strong>an</strong>’s Aga Kh<strong>an</strong> University Hospital required a robust life safety system th<strong>at</strong> wouldn’t<br />

be a burden on the busy facility during install<strong>at</strong>ion. The MR-2900 delivered.<br />

Number of Points Monitored: 1,500.<br />

Total Solution<br />

SECUTRON’s comprehensive line of products comprise a total life safety package r<strong>an</strong>ging from<br />

powerful control p<strong>an</strong>els, to intuitive <strong>an</strong>nunci<strong>at</strong>ors, to highly reliable detectors <strong>an</strong>d signals.<br />

C<strong>an</strong>ada<br />

25 Interch<strong>an</strong>ge Way<br />

Vaugh<strong>an</strong> (Toronto), Ontario<br />

L4K 5W3<br />

Telephone: (888) 732-8876<br />

Fax: (905) 660-4113<br />

U.S.A.<br />

60 Industrial Parkway<br />

Cheektowaga (Buffalo), NY<br />

14227<br />

Telephone: (888) 732-8876<br />

Fax: (888) 660-4113<br />

About our comp<strong>an</strong>y<br />

SECUTRON INC., established<br />

in 1973, is a global corpor<strong>at</strong>ion<br />

th<strong>at</strong> has been providing total<br />

fire alarm solutions since 1991.<br />

During th<strong>at</strong> time, we have<br />

established a reput<strong>at</strong>ion for<br />

quality, reliability <strong>an</strong>d costeffective<br />

solutions to life<br />

safety <strong>an</strong>d security challenges<br />

worldwide.<br />

S E C U T R O N I N C . i s a<br />

member of the Mircom Group<br />

of Comp<strong>an</strong>ies. Mircom is<br />

the largest priv<strong>at</strong>ely-held<br />

independent designer <strong>an</strong>d<br />

m<strong>an</strong>ufacturer of Fire Alarm Life<br />

Safety <strong>an</strong>d Telephone Access<br />

products in North America.<br />

The SECUTRON line of life<br />

safety products includes<br />

systems for a variety of<br />

applic<strong>at</strong>ions, from small <strong>an</strong>d<br />

simple, to large <strong>an</strong>d complex.<br />

Web Site: www.secutron.com<br />

Email: mail@secutron.com<br />

MODUL-R TM is a trademark of <strong>Secutron</strong> Inc.<br />

CAT-200<br />

Rev.0

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!