Content<br />

• Key benefits<br />

• Unique selling points<br />

• Key application area’s<br />

• Specifications<br />

• Logistical info<br />

• TCO<br />

• Competitive positioning – benchmark<br />

• Frequently asked questions<br />

Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 2


Key features and benefits<br />

Very reliable<br />

Easy to<br />

design in<br />

Flexible<br />

control<br />

options<br />

“A very reliable, easy to design in and flexible control <strong>gear</strong> <strong>for</strong><br />

<strong>CDO</strong> lamps”<br />

• <strong>Xtreme</strong> outdoor specification of 20 years lifetime (+90% survivors at 80 000 hours)<br />

• <strong>Xtreme</strong> lightning and surge protection: up to 5kA / 10kV !<br />

• 8 year warranty<br />

• Universal size, identical to the well-known CosmoPolis drivers<br />

• Form factor designed to fit in any HID luminaire/pole<br />

• Can be connected to any <strong>DALI</strong>-based network control system<br />

• Flexible stand-alone dimming with built-in dynadimmer functionality<br />

• Can be controlled directly by pilot-line, without need <strong>for</strong> external SDU<br />

Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 3


Unique Selling Points (1/5)<br />

<strong>Xtreme</strong> specification<br />

• Long Lifetime<br />

� Lifetime specification at maximum temperatures<br />

80.000 hrs (approx. 20 yrs) with min 90% survivors<br />

� Low failure rate during operational lifetime<br />

Designed <strong>for</strong> less than 0.01% (100 ppm) failures per year<br />

1<br />

• <strong>Xtreme</strong> Temperatures<br />

2<br />

� <strong>Xtreme</strong> <strong>gear</strong> is designed <strong>for</strong> long lifetime at high and low ambient<br />

temperatures - from -30°C up to 50°C<br />

• <strong>Lighting</strong> Protection<br />

3<br />

� Resistant to lightning strokes in the installation<br />

• 5kA /10kV<br />

• Gear does not get damaged, lamp stays on<br />

� Resistant to peaks and surges in the installation<br />

• 6 kV in differential mode (between Line and Neutral)<br />

• 10 kV in common mode (between Line/Neutral and Ground)<br />

Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 4


Unique Selling Points (2/5)<br />

Reliability<br />

• Moisture & Dust<br />

– Suitable <strong>for</strong> IP 23 luminaires<br />

– Resistant to moisture, dust and insects<br />

– Can be installed in the light pole<br />

– Extra protection in the fixture<br />

• Vibration & shock<br />

– Tested at high <strong>for</strong>ces (5G vibration / 30G bumps)<br />

– Winds and high poles<br />

– Bridges<br />

– Vibration from heavy traffic<br />

• Double isolation <strong>for</strong> Class II luminaires<br />

– Easy and safe design-in<br />

– No extra insulation measures required<br />

Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 5


Unique Selling Points (3/5)<br />

Intelligent Temperature Protection<br />

• To protect the driver from overheating but prevent lamps<br />

will extinguish a new protection has been integrated called<br />

“Temperature Protection”.<br />

• In case the temperature exceeds T case + 10 degrees the<br />

lamps will be dimmed to the minimum level. Result will be<br />

that temperature in the luminaire will be lowered and<br />

power-losses will be reduced.<br />

• To limit unnecessary cycling a hysteresis is build in the<br />

driver. Temperature needs to be lowered to a certain level<br />

be<strong>for</strong>e the driver will switch back to the nominal value.<br />

Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 6


Unique Selling Points (4/5)<br />

Programmable<br />

The <strong>DynaVision</strong> Product family is programmable via <strong>DALI</strong> commands. If offers<br />

maximum flexibility and opportunities to reduce stocks (through the option of<br />

changing the lamp configuration on the driver)<br />

� Programming the <strong>DynaVision</strong> <strong>DALI</strong> Drivers is<br />

possible now using:<br />

a. the <strong>DALI</strong> programmer<br />

b. the <strong>DynaVision</strong> PC tool<br />

� The <strong>DynaVision</strong> PC tool can be used to<br />

customize various driver coordinates.<br />

o Enable / Disable DynaDimmer<br />

o Enable / Disable LineSwitch<br />

o Change lamp type<br />

<strong>DALI</strong><br />

Programmer<br />

<strong>DynaVision</strong><br />

PC tool<br />

Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 7


Unique Selling Points (5/5)<br />

Programmable<br />

The following features are currently available <strong>for</strong> programming and<br />

re-configuration in the <strong>DynaVision</strong> Dali Drivers:<br />

� DynaDimmer<br />

� Line Switch<br />

� Change the lamp type<br />

The following combinations are currently possible<br />

Feature Matrix Line Switch Dynadim <strong>DALI</strong><br />

Line Switch y<br />

Dynadim Y y<br />

<strong>DALI</strong> Y<br />

To have the features available, the drivers must be programmed* using the<br />

� USB <strong>DALI</strong> programmer (same programmer as <strong>for</strong> Xitanium outdoor drivers)<br />

� The <strong>DynaVision</strong> PC tool<br />

* The programming is to be done currently by the Luminaries producers.<br />

Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 8


Key application area’s<br />

<strong>DynaVision</strong> <strong>DALI</strong> Xt drivers are aimed at application area’s below, based on key requirements:<br />

Energy savings – Reliability– Light level adjustment<br />

Urban<br />

Highway Residential Parking lot<br />

Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 9


Technical specifications (1)<br />

Key characteristics<br />

Confidential<br />

Tambient Tc Lifetime<br />

Main<br />

voltage<br />

Gear per<br />

MBC<br />

<strong>Lighting</strong> Solutions EMEA, July 2011<br />

Inrush current<br />

Ignition<br />

voltage<br />

Product<br />

min..max min..max<br />

@Tc (90%<br />

survival)<br />

min..max B type 16A<br />

[°C] [°C] [hrs] [V] # [A] [ms] Min. Max.<br />

DV <strong>DALI</strong> Xt 50 <strong>CDO</strong> -30..50 -30..80 80.000 208..277 11 52 24 1.8 2.3<br />

DV <strong>DALI</strong> Xt 70 <strong>CDO</strong> -30..50 -30..80 80.000 208..277 11 52 24 1.8 2.3<br />

DV <strong>DALI</strong> Xt 100 <strong>CDO</strong> -30..50 -30..80 80.000 208..277 5 28 47 1.8 2.3<br />

DV <strong>DALI</strong> Xt 150 <strong>CDO</strong> -30..50 -30..80 80.000 208..277 5 28 47 1.8 2.3<br />

Product<br />

Lamp<br />

power<br />

tollerance<br />

Minimum dim level Fade time<br />

Power Light full->min min->full<br />

Dim delay<br />

@start<br />

System<br />

Power<br />

[%] [%] [%] [sec] [sec] [min]<br />

DV <strong>DALI</strong> Xt 50 <strong>CDO</strong> -3..+3 75 60 100 7 300 56<br />

DV <strong>DALI</strong> Xt 70 <strong>CDO</strong> -3..+3 75 60 100 7 300 81<br />

DV <strong>DALI</strong> Xt 100 <strong>CDO</strong> -3..+3 60 48 130 9 300 108<br />

DV <strong>DALI</strong> Xt 150 <strong>CDO</strong> -3..+3 60 48 130 9 300 160<br />

Product<br />

Overvoltage protection<br />

@350Vac @400Vac<br />

Lightning surge<br />

protection<br />

common differencial<br />

mode mode<br />

Power<br />

factor<br />

Weigth<br />

[hrs] [min] [kA/kV] [kV] [-] [kg]<br />

DV <strong>DALI</strong> Xt 50 <strong>CDO</strong> 2 5 5/10 6 0.95 0.95<br />

DV <strong>DALI</strong> Xt 70 <strong>CDO</strong> 2 5 5/10 6 0.95 0.95<br />

DV <strong>DALI</strong> Xt 100 <strong>CDO</strong> 2 5 5/10 6 0.95 0.95<br />

DV <strong>DALI</strong> Xt 150 <strong>CDO</strong> 2 5 5/10 6 0.95 0.95<br />

10


Technical specifications (2)<br />

Dimensions and connectors<br />

<strong>CDO</strong><br />

<strong>CDO</strong><br />

<strong>CDO</strong><br />

<strong>CDO</strong><br />

Lamp<br />

Digital Interface<br />

• Housing dimensions are the same as the HID-PrimaVision Xt 90W & 140W CPO <strong>gear</strong><br />

• The lamp connectors are on the top side and the digital interface connectors are on the<br />

bottom side<br />

Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 11


Technical specifications (3)<br />

Wiring<br />

ground<br />

Power-line<br />

communication<br />

OLC<br />

<strong>DALI</strong><br />

L<br />

~<br />

N ~<br />

DA<br />

DA<br />

L Lamp<br />

L<br />

<strong>DynaVision</strong> Xt<br />

Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 12


Logistics info<br />

• <strong>DynaVision</strong> <strong>DALI</strong> <strong>Xtreme</strong> <strong>CDO</strong> 50, 70, 100, 150W: from July onwards<br />

• Logistical in<strong>for</strong>mation<br />

Name 12NC EOC Pcs per box<br />

DV <strong>DALI</strong> Xt 50 <strong>CDO</strong> 9137 006 79266 871829115859200<br />

12<br />

DV <strong>DALI</strong> Xt 70 <strong>CDO</strong> 9137 006 79366 871829115863900<br />

12<br />

DV <strong>DALI</strong> Xt 100 <strong>CDO</strong> 9137 006 79466 871829115865300 12<br />

DV <strong>DALI</strong> Xt 150 <strong>CDO</strong> 9137 006 79566 871829115867700<br />

• Tools <strong>for</strong> programming of <strong>DynaVision</strong> drivers<br />

– USB-<strong>DALI</strong> interface: same interface as used <strong>for</strong> Xitanium drivers. We will provide<br />

one interface <strong>for</strong> free to enable easy transition.<br />

– Software: <strong>DynaVision</strong> PC tool: can be downloaded on our website<br />

Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 13<br />

12


TCO<br />

The use of the dimming possibilities of <strong>DynaVision</strong> <strong>DALI</strong> Xt <strong>gear</strong> allows <strong>for</strong><br />

a drastic reduction in TCO and a payback of 0.5 – 2 years<br />

Get the tool to make simulations <strong>for</strong> your project on:<br />

http://www.lighting.philips.co.uk/subsites/oem/applications/outdoor_applicationpage.wpd click on “TCO Tool”<br />

Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 14


Product benchmark (1)<br />

Technology benchmark - internal<br />

Features EM <strong>gear</strong> Gen III Xt<br />

Controllability Communication<br />

Interface<br />

no 1-10V <strong>DALI</strong><br />

Dimming Mains Dimming 1-10V DynaDimmer / <strong>DALI</strong> /<br />

Line switch<br />

Reliability Lifetime 50.000 (incl igniter) 50.000 80.000<br />

Failure Rate/year 1% <strong>for</strong> igniter 1% 0.5%<br />

Lightning<br />

Protection<br />

no no 10kV / 5kA<br />

Surges protection no 2kV - differential mode<br />

4kV - common mode<br />

Lamp EOL<br />

Protection<br />

no yes yes<br />

5kV - differential mode<br />

6kV - common mode<br />

Warranty 5 years 3 years 8 years (incl Lightning)<br />

Application Efficiency 80-90% ∼ 92% ∼ 92%<br />

Mains Range 220 - 240 V 220 - 240 V 208 - 277V<br />

Lamp Power<br />

Regulation<br />

Temperature<br />

Range<br />

±10% ± 3% ± 3%<br />

-30 to +40ºC -20ºC to 45ºC -30ºC to 50ºC<br />

Confidential<br />

<strong>Lighting</strong> Solutions EMEA<br />

<strong>Lighting</strong> Solutions EMEA, July 2011 15


Product benchmark (2)<br />

Competitors benchmark - external<br />

Features <strong>DALI</strong> Xt Competitor 1 Competitor 2 Competitor 3<br />

Controllability Communication<br />

Interface<br />

Dimming Dali / DynaDimmer/<br />

PilotLine Control<br />

Dali <strong>DALI</strong>/ DSI/ stepDIM Own system<br />

Digital interface<br />

(100 % – 40 % light output)<br />

Own system<br />

Reliability Lifetime 80.000 60.000 60.000* 60.000*<br />

Failure Rate 0.1% 0.8% 0.1% 0.1%<br />

Lightning<br />

Protection<br />

Application Available lamp<br />

types<br />

no no no no<br />

Surges protection 4kV - differential mode<br />

6kV - common mode<br />

5kV – common mode N/A N/A<br />

Warranty 8 years 5 years 5 (+ 3 paid) N/A<br />

CPO, SON, <strong>CDO</strong> CPO, SON, <strong>CDO</strong> (only<br />

> 100W)<br />

CPO (not<br />

released!), SON,<br />

<strong>CDO</strong><br />

50 -100 %dimmer,<br />

ambient sensor, light<br />

sensor<br />

Mains V/ Range V 187 - 346V 198 – 254 V 200 - 265V 120 – 277V<br />

Lamp Power<br />

Regulation<br />

Temperature<br />

Range<br />

Details: see SharePoint<br />

OEM-Channel Product In<strong>for</strong>mation > Product<br />

in<strong>for</strong>mation > HID-<strong>DynaVision</strong> <strong>DALI</strong> Xt SON ><br />

Technical Info > Competitor database outdoor<br />

± 3% N/A N/A N/A<br />

CPO (not released!),<br />

SON<br />

-30ºC to 50ºC -25ºC to 55ºC -20ºC to 50ºC -20ºC to 55ºC<br />

Confidential<br />

* To be validated<br />

<strong>Lighting</strong> Solutions EMEA<br />

<strong>Lighting</strong> Solutions EMEA, July 2011 16


Frequently asked questions (1/3)<br />

<strong>Xtreme</strong> Gears - General Questions<br />

• Can I replace fixed output with <strong>DALI</strong> drivers?<br />

– Yes, the dimension and thermal behaviour is similar with fixed output of Lumistep.<br />

• Can I use CosmoPolis 45W with <strong>DALI</strong>?<br />

– Begin 2011 a specific dimmable 45W system will be introduced, lamp will be dimmable to 30W<br />

(=66%)<br />

• Can I use <strong>DALI</strong> drivers together with a Dynadimmer?<br />

– This is not needed, the new drivers have an integrated programmable Dynadimmer. Special<br />

PC-tool tool is needed to enable and program this feature.<br />

• Can I use it together with an SDU to dim via a pilot-line?<br />

– This not needed, the new <strong>DALI</strong> drivers can be controlled directly by the pilot line. Just connect<br />

phase-Neutral directly on the <strong>DALI</strong> to dim. These <strong>DALI</strong> lines are fully sdurge protected<br />

(10kV/5kA)<br />

• Are <strong>DALI</strong> drivers available without the <strong>Xtreme</strong> Surge Protection?<br />

– No, <strong>DALI</strong> drivers are only available with the <strong>Xtreme</strong> surge protection, es indicated also the<br />

<strong>DALI</strong> lines have this <strong>Xtreme</strong> lightning protection.<br />

• When should I choose <strong>for</strong> Surge Protection?<br />

– Surge protection is always advised, in some circumstances the start<strong>Xtreme</strong> may be use (see<br />

selection tree)<br />

• Other suppliers also claim the 10kV protection; what is the difference?<br />

– The difference with <strong>Philips</strong> <strong>Xtreme</strong> is the high sustainable current (5kA) in the protection circuit<br />

to prevent internal components will be damaged at lightning strokes.<br />

Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 17


Frequently asked questions (2/3)<br />

<strong>Xtreme</strong> Gears - General Questions<br />

• How is lifetime of <strong>Philips</strong> drivers specified?<br />

– The <strong>Xtreme</strong> lifetime of 80.000 hours is specified as operation hours at continuous worst case<br />

conditions such as maximum Tcase temperature (80°C), low mains voltage (198V) and low lamp<br />

voltage (85V). Competition <strong>gear</strong>’s lifetime is normally specified at nominal conditions and is<br />

limited to 50 or 60.000 hours.<br />

• Can the lamp start in a dimmed mode?<br />

– Yes, <strong>Philips</strong> calls this feature “Adjustable Power Output” and can be set via the <strong>DALI</strong> input.<br />

Special configuration software will be needed.<br />

• Will also a 1-10V interface be available?<br />

– No, the 1-10V functionality will not be supported anymore because most functions are now<br />

integrated (SDU, Dynadimmer). For replacement old driver we recommend to remove the<br />

additional components or replace 1-10V unit <strong>for</strong> a <strong>DALI</strong> version.<br />

• Is the behavior of the <strong>DALI</strong> version same as the existing <strong>Xtreme</strong> versions<br />

– Yes, temperature and EMI behavior is similar with fixed output and LumiStep<br />

• What does designed <strong>for</strong> 100ppm mean?<br />

– Design and manufacturing is set-up <strong>for</strong> maximum 100 pcs per year returned from the field out of<br />

one million products sold. This extreme reliability has been achieved by <strong>Philips</strong> long time<br />

experience in outdoor lighting during design and our quality testing procedures. Actual<br />

per<strong>for</strong>mance so far is confirming this per<strong>for</strong>mance.<br />

Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 18


Frequently asked questions (3/3)<br />

<strong>Xtreme</strong> Gears - General Questions<br />

• Where to get the <strong>DALI</strong> command set?<br />

– <strong>DALI</strong> standards have to be requested at <strong>DALI</strong> consortium (www.dali-ag.org).<br />

• Will it work with other <strong>DALI</strong> systems than <strong>Philips</strong> Starsense?<br />

– All components that make use of standard <strong>DALI</strong> are able to control the <strong>DynaVision</strong> <strong>DALI</strong> <strong>Xtreme</strong><br />

<strong>gear</strong><br />

• Are there private <strong>DALI</strong> commands?<br />

– <strong>Philips</strong> has integrated private commands via so-called memory banks, these commands are <strong>for</strong><br />

<strong>Philips</strong> use only since they are not supported by international norms. <strong>Philips</strong> could change the<br />

commands over time.<br />

• Where can I found more in<strong>for</strong>mation<br />

– On the internet further in<strong>for</strong>mation can be found on our OEM webpage: www.philips.com/oem<br />

• How can I set/read <strong>DALI</strong>?<br />

– Any <strong>DALI</strong> controller can be used to read or set <strong>DALI</strong> parameters. <strong>Philips</strong> will release a software<br />

package that will work with several <strong>DALI</strong> interface modules. If needed your local <strong>Philips</strong> contact<br />

will be able to help you.<br />

Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 19


SON<br />

<strong>CDO</strong><br />

CPO<br />

Confidential<br />

Dimming<br />

Method<br />

Dim level / Lamp type<br />

Min dim level Ra Tc Lifetime (5%) Maintenance Time<br />

Types Power Light 100% Min 100% Min 100% Max Max dimmed<br />

to dim<br />

level<br />

level<br />

dimmed<br />

50% of life<br />

50% of life<br />

Elect 50W 60% 50% 20 8.000 >70% 4 min<br />

Elect 45W 66% 55% 65 60 2.800 2.800 16.000 16.000 80% 2 min<br />

Elect 60W 60% 50% 65 60 2.800 2.800 16.000 16.000 80% 2 min<br />

Elect 90W 60% 50% 65 60 2.800 2.800 16.000 16.000 80% 2 min<br />

Elect 140W 60% 50% 65 60 2.800 2.800 16.000 16.000 80% 2 min<br />

Elect 210W 60% 50% 90 80 3.000 3.000 16.000 16.000 80% 2 min<br />

SOX Not dimmable, gas temperature too low → severe efficiency drop<br />

HPL/ML Not dimmable, risk of extinguishing lamps in lifetime due to lamp voltage increase<br />

HPI Not dimmable, lamp voltage increase → extinguishing lamps, crack pinch due to low temperature, colour shift<br />

MHN Not dimmable, sever colour instability and risk of crack pinch<br />

CDM Not dimmable, color instability and blackening – exception <strong>for</strong> Lightboost ( new range)<br />

CDM MW Dimmable, systems in introduction phase<br />

<strong>Lighting</strong> Solutions EMEA, July 2011<br />

21


Useful links<br />

<strong>Philips</strong> Guarantee program <strong>for</strong> Lamps & Gear<br />

http://www.philips.com/oem/guarantee<br />

eCat Link to the Outdoor <strong>gear</strong>s Portfolio (<strong>for</strong> CPO, SON, <strong>CDO</strong>)<br />

eCat Link to the CDMe Medium Wattage <strong>gear</strong>s<br />

Link to the <strong>Xtreme</strong> Movie<br />

Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 22


Wiring <strong>DynaVision</strong> <strong>DALI</strong> Drivers<br />

<strong>for</strong> different Control Versions<br />

Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 23


Line Switch<br />

Pilot-line control<br />

Wiring diagram<br />

Earth<br />

N<br />

L<br />

Pilot line<br />

Control cabinet<br />

Extra wire to pole(s)<br />

DA<br />

DA<br />

~<br />

~<br />

L<br />

L<br />

<strong>DynaVision</strong> Xt<br />

<strong>DynaVision</strong> Xt<br />

Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 24<br />

Lamp<br />

GROUP<br />

MANAGEMENT


Presence Sensor<br />

Wiring diagram<br />

Earth<br />

N<br />

L<br />

Presence<br />

detection<br />

DA<br />

DA<br />

~<br />

~<br />

L<br />

L<br />

<strong>DynaVision</strong> Xt<br />

<strong>DynaVision</strong> Xt<br />

Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 25<br />

Lamp<br />

LIGHTPOINT<br />

CONTRIOL


Networked PowerLine - LON<br />

Wiring diagram<br />

ground<br />

Power-line<br />

communication<br />

OLC<br />

<strong>DALI</strong><br />

L<br />

~<br />

N ~<br />

DA<br />

DA<br />

L Lamp<br />

L<br />

<strong>DynaVision</strong> Xt<br />

<strong>DynaVision</strong> Xt<br />

LIGHTPOINT<br />

MANAGEMENT<br />

Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 26


Networked RF<br />

Wiring diagram<br />

Earth<br />

N<br />

L<br />

Wireless<br />

OLC<br />

DA<br />

DA<br />

~<br />

~<br />

L<br />

L<br />

<strong>DynaVision</strong> Xt<br />

<strong>DynaVision</strong> Xt<br />

Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 27<br />

Lamp<br />

LIGHTPOINT<br />

MANAGEMENT


Switch to new technology - Replacement<br />

DV 1-10V<br />

Does the 1-10V<br />

driver needs to<br />

be replaced?<br />

DV <strong>DALI</strong> Xt<br />

Confidential<br />

+<br />

+<br />

SDU 1-10V<br />

SON<br />

<strong>CDO</strong><br />

When the 1-10V driver <strong>for</strong> SON or <strong>CDO</strong> fails, the driver<br />

can be changed <strong>for</strong><br />

• DV <strong>DALI</strong> Xt <strong>for</strong> SON or <strong>CDO</strong> and<br />

• <strong>DALI</strong> Master + Programming Software (one set<br />

<strong>for</strong> all the DV <strong>DALI</strong> Xt programming)<br />

Program the active level<br />

• SDU01 -> Active level = HIGH<br />

• SDU11 -> Active level = LOW<br />

Remove the SDU and 1-10V driver and replace both<br />

with the pre-programmed DV <strong>DALI</strong> Xt<br />

SON<br />

<strong>CDO</strong><br />

CPO<br />

<strong>Lighting</strong> Solutions EMEA, July 2011


Switch to new technology - Replacement<br />

DV 1-10V<br />

Does the 1-10V<br />

driver needs to<br />

be replaced?<br />

Confidential<br />

+<br />

DV <strong>DALI</strong> Xt<br />

Dynadimmer<br />

1-10V<br />

+<br />

+<br />

When the 1-10V driver <strong>for</strong> SON or <strong>CDO</strong> fails, the driver<br />

can be changed <strong>for</strong><br />

• DV <strong>DALI</strong> Xt <strong>for</strong> SON or <strong>CDO</strong> and<br />

Program the dimming scenario<br />

• Read out the Dynadimmer and<br />

• Reproduce the same schedule in the DV <strong>DALI</strong><br />

Xt programming tool<br />

• Program the driver<br />

Remove the Dynadimmer and 1-10V driver and replace<br />

both with the pre-programmed DV <strong>DALI</strong> Xt<br />

SON<br />

<strong>CDO</strong><br />

CPO<br />

SON<br />

<strong>CDO</strong><br />

<strong>Lighting</strong> Solutions EMEA, July 2011


Feature description<br />

1-10V:<br />

Analog input <strong>for</strong> electronic driver, 10V or open is 100%. 0-1V is minimum value of light (level is depending on lamp type)<br />

Benefits: Simple dimming interface<br />

Lumistep:<br />

Pre-programmed dimming sequence controlled by switching on/off. Three different timing available 6, 8 and 10 hours<br />

dimming. Dimming level is fixed on 60% (power)<br />

Benefits: Simple dimming without external control, timing determined by on/off cycle (last 3 nights)<br />

<strong>DALI</strong>:<br />

Universal Digital Addressable <strong>Lighting</strong> Interface.<br />

Defined in standard EN62386, all <strong>Xtreme</strong> drivers are supporting part 101, 102 and 203<br />

Benefits: Digital universal dimming interface to communicate with <strong>DALI</strong> compliant control systems<br />

LineSwitch:<br />

Interface <strong>for</strong> easy dimming via pilot-line or external sensor (presence)<br />

Dimming to preset-level (default 60%) can be controlled by applying directly a 208-277V between <strong>DALI</strong> lines<br />

<strong>DALI</strong> line terminals fully lightning protected (10kV/5kA)<br />

Dim level / speed / inversion can be programmed via <strong>DALI</strong> input (PC-tool required)<br />

Benefits: Simple dimming by extra pilot-line or simple sensor (presence)<br />

Dynadimmer:<br />

All programmable <strong>Xtreme</strong> drivers have an integrated Dynadimmer (5 steps, dim level adjustable)<br />

Dimming sequence, dim levels and speed can be programmed via <strong>DALI</strong> input (PC-tool required)<br />

Benefits: Simple flexible dimming without external control, timing determined by on/off cycle<br />

Adjustable Output Power<br />

Adjustable power Output to regulate light to desired optimum value<br />

Output power can be programmed via <strong>DALI</strong> input (PC-tool required)<br />

Benefits: Adjust right amount of power (light) <strong>for</strong> the application<br />

Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 30

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!