DynaVision DALI Xtreme gear for CDO - Philips Lighting
DynaVision DALI Xtreme gear for CDO - Philips Lighting
DynaVision DALI Xtreme gear for CDO - Philips Lighting
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>DynaVision</strong> <strong>DALI</strong> <strong>Xtreme</strong> <strong>gear</strong> <strong>for</strong> <strong>CDO</strong><br />
External commercial presentation<br />
<strong>Philips</strong> <strong>Lighting</strong><br />
<strong>Lighting</strong> Solutions EMEA<br />
July 2011
Content<br />
• Key benefits<br />
• Unique selling points<br />
• Key application area’s<br />
• Specifications<br />
• Logistical info<br />
• TCO<br />
• Competitive positioning – benchmark<br />
• Frequently asked questions<br />
Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 2
Key features and benefits<br />
Very reliable<br />
Easy to<br />
design in<br />
Flexible<br />
control<br />
options<br />
“A very reliable, easy to design in and flexible control <strong>gear</strong> <strong>for</strong><br />
<strong>CDO</strong> lamps”<br />
• <strong>Xtreme</strong> outdoor specification of 20 years lifetime (+90% survivors at 80 000 hours)<br />
• <strong>Xtreme</strong> lightning and surge protection: up to 5kA / 10kV !<br />
• 8 year warranty<br />
• Universal size, identical to the well-known CosmoPolis drivers<br />
• Form factor designed to fit in any HID luminaire/pole<br />
• Can be connected to any <strong>DALI</strong>-based network control system<br />
• Flexible stand-alone dimming with built-in dynadimmer functionality<br />
• Can be controlled directly by pilot-line, without need <strong>for</strong> external SDU<br />
Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 3
Unique Selling Points (1/5)<br />
<strong>Xtreme</strong> specification<br />
• Long Lifetime<br />
� Lifetime specification at maximum temperatures<br />
80.000 hrs (approx. 20 yrs) with min 90% survivors<br />
� Low failure rate during operational lifetime<br />
Designed <strong>for</strong> less than 0.01% (100 ppm) failures per year<br />
1<br />
• <strong>Xtreme</strong> Temperatures<br />
2<br />
� <strong>Xtreme</strong> <strong>gear</strong> is designed <strong>for</strong> long lifetime at high and low ambient<br />
temperatures - from -30°C up to 50°C<br />
• <strong>Lighting</strong> Protection<br />
3<br />
� Resistant to lightning strokes in the installation<br />
• 5kA /10kV<br />
• Gear does not get damaged, lamp stays on<br />
� Resistant to peaks and surges in the installation<br />
• 6 kV in differential mode (between Line and Neutral)<br />
• 10 kV in common mode (between Line/Neutral and Ground)<br />
Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 4
Unique Selling Points (2/5)<br />
Reliability<br />
• Moisture & Dust<br />
– Suitable <strong>for</strong> IP 23 luminaires<br />
– Resistant to moisture, dust and insects<br />
– Can be installed in the light pole<br />
– Extra protection in the fixture<br />
• Vibration & shock<br />
– Tested at high <strong>for</strong>ces (5G vibration / 30G bumps)<br />
– Winds and high poles<br />
– Bridges<br />
– Vibration from heavy traffic<br />
• Double isolation <strong>for</strong> Class II luminaires<br />
– Easy and safe design-in<br />
– No extra insulation measures required<br />
Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 5
Unique Selling Points (3/5)<br />
Intelligent Temperature Protection<br />
• To protect the driver from overheating but prevent lamps<br />
will extinguish a new protection has been integrated called<br />
“Temperature Protection”.<br />
• In case the temperature exceeds T case + 10 degrees the<br />
lamps will be dimmed to the minimum level. Result will be<br />
that temperature in the luminaire will be lowered and<br />
power-losses will be reduced.<br />
• To limit unnecessary cycling a hysteresis is build in the<br />
driver. Temperature needs to be lowered to a certain level<br />
be<strong>for</strong>e the driver will switch back to the nominal value.<br />
Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 6
Unique Selling Points (4/5)<br />
Programmable<br />
The <strong>DynaVision</strong> Product family is programmable via <strong>DALI</strong> commands. If offers<br />
maximum flexibility and opportunities to reduce stocks (through the option of<br />
changing the lamp configuration on the driver)<br />
� Programming the <strong>DynaVision</strong> <strong>DALI</strong> Drivers is<br />
possible now using:<br />
a. the <strong>DALI</strong> programmer<br />
b. the <strong>DynaVision</strong> PC tool<br />
� The <strong>DynaVision</strong> PC tool can be used to<br />
customize various driver coordinates.<br />
o Enable / Disable DynaDimmer<br />
o Enable / Disable LineSwitch<br />
o Change lamp type<br />
<strong>DALI</strong><br />
Programmer<br />
<strong>DynaVision</strong><br />
PC tool<br />
Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 7
Unique Selling Points (5/5)<br />
Programmable<br />
The following features are currently available <strong>for</strong> programming and<br />
re-configuration in the <strong>DynaVision</strong> Dali Drivers:<br />
� DynaDimmer<br />
� Line Switch<br />
� Change the lamp type<br />
The following combinations are currently possible<br />
Feature Matrix Line Switch Dynadim <strong>DALI</strong><br />
Line Switch y<br />
Dynadim Y y<br />
<strong>DALI</strong> Y<br />
To have the features available, the drivers must be programmed* using the<br />
� USB <strong>DALI</strong> programmer (same programmer as <strong>for</strong> Xitanium outdoor drivers)<br />
� The <strong>DynaVision</strong> PC tool<br />
* The programming is to be done currently by the Luminaries producers.<br />
Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 8
Key application area’s<br />
<strong>DynaVision</strong> <strong>DALI</strong> Xt drivers are aimed at application area’s below, based on key requirements:<br />
Energy savings – Reliability– Light level adjustment<br />
Urban<br />
Highway Residential Parking lot<br />
Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 9
Technical specifications (1)<br />
Key characteristics<br />
Confidential<br />
Tambient Tc Lifetime<br />
Main<br />
voltage<br />
Gear per<br />
MBC<br />
<strong>Lighting</strong> Solutions EMEA, July 2011<br />
Inrush current<br />
Ignition<br />
voltage<br />
Product<br />
min..max min..max<br />
@Tc (90%<br />
survival)<br />
min..max B type 16A<br />
[°C] [°C] [hrs] [V] # [A] [ms] Min. Max.<br />
DV <strong>DALI</strong> Xt 50 <strong>CDO</strong> -30..50 -30..80 80.000 208..277 11 52 24 1.8 2.3<br />
DV <strong>DALI</strong> Xt 70 <strong>CDO</strong> -30..50 -30..80 80.000 208..277 11 52 24 1.8 2.3<br />
DV <strong>DALI</strong> Xt 100 <strong>CDO</strong> -30..50 -30..80 80.000 208..277 5 28 47 1.8 2.3<br />
DV <strong>DALI</strong> Xt 150 <strong>CDO</strong> -30..50 -30..80 80.000 208..277 5 28 47 1.8 2.3<br />
Product<br />
Lamp<br />
power<br />
tollerance<br />
Minimum dim level Fade time<br />
Power Light full->min min->full<br />
Dim delay<br />
@start<br />
System<br />
Power<br />
[%] [%] [%] [sec] [sec] [min]<br />
DV <strong>DALI</strong> Xt 50 <strong>CDO</strong> -3..+3 75 60 100 7 300 56<br />
DV <strong>DALI</strong> Xt 70 <strong>CDO</strong> -3..+3 75 60 100 7 300 81<br />
DV <strong>DALI</strong> Xt 100 <strong>CDO</strong> -3..+3 60 48 130 9 300 108<br />
DV <strong>DALI</strong> Xt 150 <strong>CDO</strong> -3..+3 60 48 130 9 300 160<br />
Product<br />
Overvoltage protection<br />
@350Vac @400Vac<br />
Lightning surge<br />
protection<br />
common differencial<br />
mode mode<br />
Power<br />
factor<br />
Weigth<br />
[hrs] [min] [kA/kV] [kV] [-] [kg]<br />
DV <strong>DALI</strong> Xt 50 <strong>CDO</strong> 2 5 5/10 6 0.95 0.95<br />
DV <strong>DALI</strong> Xt 70 <strong>CDO</strong> 2 5 5/10 6 0.95 0.95<br />
DV <strong>DALI</strong> Xt 100 <strong>CDO</strong> 2 5 5/10 6 0.95 0.95<br />
DV <strong>DALI</strong> Xt 150 <strong>CDO</strong> 2 5 5/10 6 0.95 0.95<br />
10
Technical specifications (2)<br />
Dimensions and connectors<br />
<strong>CDO</strong><br />
<strong>CDO</strong><br />
<strong>CDO</strong><br />
<strong>CDO</strong><br />
Lamp<br />
Digital Interface<br />
• Housing dimensions are the same as the HID-PrimaVision Xt 90W & 140W CPO <strong>gear</strong><br />
• The lamp connectors are on the top side and the digital interface connectors are on the<br />
bottom side<br />
Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 11
Technical specifications (3)<br />
Wiring<br />
ground<br />
Power-line<br />
communication<br />
OLC<br />
<strong>DALI</strong><br />
L<br />
~<br />
N ~<br />
DA<br />
DA<br />
L Lamp<br />
L<br />
<strong>DynaVision</strong> Xt<br />
Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 12
Logistics info<br />
• <strong>DynaVision</strong> <strong>DALI</strong> <strong>Xtreme</strong> <strong>CDO</strong> 50, 70, 100, 150W: from July onwards<br />
• Logistical in<strong>for</strong>mation<br />
Name 12NC EOC Pcs per box<br />
DV <strong>DALI</strong> Xt 50 <strong>CDO</strong> 9137 006 79266 871829115859200<br />
12<br />
DV <strong>DALI</strong> Xt 70 <strong>CDO</strong> 9137 006 79366 871829115863900<br />
12<br />
DV <strong>DALI</strong> Xt 100 <strong>CDO</strong> 9137 006 79466 871829115865300 12<br />
DV <strong>DALI</strong> Xt 150 <strong>CDO</strong> 9137 006 79566 871829115867700<br />
• Tools <strong>for</strong> programming of <strong>DynaVision</strong> drivers<br />
– USB-<strong>DALI</strong> interface: same interface as used <strong>for</strong> Xitanium drivers. We will provide<br />
one interface <strong>for</strong> free to enable easy transition.<br />
– Software: <strong>DynaVision</strong> PC tool: can be downloaded on our website<br />
Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 13<br />
12
TCO<br />
The use of the dimming possibilities of <strong>DynaVision</strong> <strong>DALI</strong> Xt <strong>gear</strong> allows <strong>for</strong><br />
a drastic reduction in TCO and a payback of 0.5 – 2 years<br />
Get the tool to make simulations <strong>for</strong> your project on:<br />
http://www.lighting.philips.co.uk/subsites/oem/applications/outdoor_applicationpage.wpd click on “TCO Tool”<br />
Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 14
Product benchmark (1)<br />
Technology benchmark - internal<br />
Features EM <strong>gear</strong> Gen III Xt<br />
Controllability Communication<br />
Interface<br />
no 1-10V <strong>DALI</strong><br />
Dimming Mains Dimming 1-10V DynaDimmer / <strong>DALI</strong> /<br />
Line switch<br />
Reliability Lifetime 50.000 (incl igniter) 50.000 80.000<br />
Failure Rate/year 1% <strong>for</strong> igniter 1% 0.5%<br />
Lightning<br />
Protection<br />
no no 10kV / 5kA<br />
Surges protection no 2kV - differential mode<br />
4kV - common mode<br />
Lamp EOL<br />
Protection<br />
no yes yes<br />
5kV - differential mode<br />
6kV - common mode<br />
Warranty 5 years 3 years 8 years (incl Lightning)<br />
Application Efficiency 80-90% ∼ 92% ∼ 92%<br />
Mains Range 220 - 240 V 220 - 240 V 208 - 277V<br />
Lamp Power<br />
Regulation<br />
Temperature<br />
Range<br />
±10% ± 3% ± 3%<br />
-30 to +40ºC -20ºC to 45ºC -30ºC to 50ºC<br />
Confidential<br />
<strong>Lighting</strong> Solutions EMEA<br />
<strong>Lighting</strong> Solutions EMEA, July 2011 15
Product benchmark (2)<br />
Competitors benchmark - external<br />
Features <strong>DALI</strong> Xt Competitor 1 Competitor 2 Competitor 3<br />
Controllability Communication<br />
Interface<br />
Dimming Dali / DynaDimmer/<br />
PilotLine Control<br />
Dali <strong>DALI</strong>/ DSI/ stepDIM Own system<br />
Digital interface<br />
(100 % – 40 % light output)<br />
Own system<br />
Reliability Lifetime 80.000 60.000 60.000* 60.000*<br />
Failure Rate 0.1% 0.8% 0.1% 0.1%<br />
Lightning<br />
Protection<br />
Application Available lamp<br />
types<br />
no no no no<br />
Surges protection 4kV - differential mode<br />
6kV - common mode<br />
5kV – common mode N/A N/A<br />
Warranty 8 years 5 years 5 (+ 3 paid) N/A<br />
CPO, SON, <strong>CDO</strong> CPO, SON, <strong>CDO</strong> (only<br />
> 100W)<br />
CPO (not<br />
released!), SON,<br />
<strong>CDO</strong><br />
50 -100 %dimmer,<br />
ambient sensor, light<br />
sensor<br />
Mains V/ Range V 187 - 346V 198 – 254 V 200 - 265V 120 – 277V<br />
Lamp Power<br />
Regulation<br />
Temperature<br />
Range<br />
Details: see SharePoint<br />
OEM-Channel Product In<strong>for</strong>mation > Product<br />
in<strong>for</strong>mation > HID-<strong>DynaVision</strong> <strong>DALI</strong> Xt SON ><br />
Technical Info > Competitor database outdoor<br />
± 3% N/A N/A N/A<br />
CPO (not released!),<br />
SON<br />
-30ºC to 50ºC -25ºC to 55ºC -20ºC to 50ºC -20ºC to 55ºC<br />
Confidential<br />
* To be validated<br />
<strong>Lighting</strong> Solutions EMEA<br />
<strong>Lighting</strong> Solutions EMEA, July 2011 16
Frequently asked questions (1/3)<br />
<strong>Xtreme</strong> Gears - General Questions<br />
• Can I replace fixed output with <strong>DALI</strong> drivers?<br />
– Yes, the dimension and thermal behaviour is similar with fixed output of Lumistep.<br />
• Can I use CosmoPolis 45W with <strong>DALI</strong>?<br />
– Begin 2011 a specific dimmable 45W system will be introduced, lamp will be dimmable to 30W<br />
(=66%)<br />
• Can I use <strong>DALI</strong> drivers together with a Dynadimmer?<br />
– This is not needed, the new drivers have an integrated programmable Dynadimmer. Special<br />
PC-tool tool is needed to enable and program this feature.<br />
• Can I use it together with an SDU to dim via a pilot-line?<br />
– This not needed, the new <strong>DALI</strong> drivers can be controlled directly by the pilot line. Just connect<br />
phase-Neutral directly on the <strong>DALI</strong> to dim. These <strong>DALI</strong> lines are fully sdurge protected<br />
(10kV/5kA)<br />
• Are <strong>DALI</strong> drivers available without the <strong>Xtreme</strong> Surge Protection?<br />
– No, <strong>DALI</strong> drivers are only available with the <strong>Xtreme</strong> surge protection, es indicated also the<br />
<strong>DALI</strong> lines have this <strong>Xtreme</strong> lightning protection.<br />
• When should I choose <strong>for</strong> Surge Protection?<br />
– Surge protection is always advised, in some circumstances the start<strong>Xtreme</strong> may be use (see<br />
selection tree)<br />
• Other suppliers also claim the 10kV protection; what is the difference?<br />
– The difference with <strong>Philips</strong> <strong>Xtreme</strong> is the high sustainable current (5kA) in the protection circuit<br />
to prevent internal components will be damaged at lightning strokes.<br />
Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 17
Frequently asked questions (2/3)<br />
<strong>Xtreme</strong> Gears - General Questions<br />
• How is lifetime of <strong>Philips</strong> drivers specified?<br />
– The <strong>Xtreme</strong> lifetime of 80.000 hours is specified as operation hours at continuous worst case<br />
conditions such as maximum Tcase temperature (80°C), low mains voltage (198V) and low lamp<br />
voltage (85V). Competition <strong>gear</strong>’s lifetime is normally specified at nominal conditions and is<br />
limited to 50 or 60.000 hours.<br />
• Can the lamp start in a dimmed mode?<br />
– Yes, <strong>Philips</strong> calls this feature “Adjustable Power Output” and can be set via the <strong>DALI</strong> input.<br />
Special configuration software will be needed.<br />
• Will also a 1-10V interface be available?<br />
– No, the 1-10V functionality will not be supported anymore because most functions are now<br />
integrated (SDU, Dynadimmer). For replacement old driver we recommend to remove the<br />
additional components or replace 1-10V unit <strong>for</strong> a <strong>DALI</strong> version.<br />
• Is the behavior of the <strong>DALI</strong> version same as the existing <strong>Xtreme</strong> versions<br />
– Yes, temperature and EMI behavior is similar with fixed output and LumiStep<br />
• What does designed <strong>for</strong> 100ppm mean?<br />
– Design and manufacturing is set-up <strong>for</strong> maximum 100 pcs per year returned from the field out of<br />
one million products sold. This extreme reliability has been achieved by <strong>Philips</strong> long time<br />
experience in outdoor lighting during design and our quality testing procedures. Actual<br />
per<strong>for</strong>mance so far is confirming this per<strong>for</strong>mance.<br />
Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 18
Frequently asked questions (3/3)<br />
<strong>Xtreme</strong> Gears - General Questions<br />
• Where to get the <strong>DALI</strong> command set?<br />
– <strong>DALI</strong> standards have to be requested at <strong>DALI</strong> consortium (www.dali-ag.org).<br />
• Will it work with other <strong>DALI</strong> systems than <strong>Philips</strong> Starsense?<br />
– All components that make use of standard <strong>DALI</strong> are able to control the <strong>DynaVision</strong> <strong>DALI</strong> <strong>Xtreme</strong><br />
<strong>gear</strong><br />
• Are there private <strong>DALI</strong> commands?<br />
– <strong>Philips</strong> has integrated private commands via so-called memory banks, these commands are <strong>for</strong><br />
<strong>Philips</strong> use only since they are not supported by international norms. <strong>Philips</strong> could change the<br />
commands over time.<br />
• Where can I found more in<strong>for</strong>mation<br />
– On the internet further in<strong>for</strong>mation can be found on our OEM webpage: www.philips.com/oem<br />
• How can I set/read <strong>DALI</strong>?<br />
– Any <strong>DALI</strong> controller can be used to read or set <strong>DALI</strong> parameters. <strong>Philips</strong> will release a software<br />
package that will work with several <strong>DALI</strong> interface modules. If needed your local <strong>Philips</strong> contact<br />
will be able to help you.<br />
Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 19
SON<br />
<strong>CDO</strong><br />
CPO<br />
Confidential<br />
Dimming<br />
Method<br />
Dim level / Lamp type<br />
Min dim level Ra Tc Lifetime (5%) Maintenance Time<br />
Types Power Light 100% Min 100% Min 100% Max Max dimmed<br />
to dim<br />
level<br />
level<br />
dimmed<br />
50% of life<br />
50% of life<br />
Elect 50W 60% 50% 20 8.000 >70% 4 min<br />
Elect 45W 66% 55% 65 60 2.800 2.800 16.000 16.000 80% 2 min<br />
Elect 60W 60% 50% 65 60 2.800 2.800 16.000 16.000 80% 2 min<br />
Elect 90W 60% 50% 65 60 2.800 2.800 16.000 16.000 80% 2 min<br />
Elect 140W 60% 50% 65 60 2.800 2.800 16.000 16.000 80% 2 min<br />
Elect 210W 60% 50% 90 80 3.000 3.000 16.000 16.000 80% 2 min<br />
SOX Not dimmable, gas temperature too low → severe efficiency drop<br />
HPL/ML Not dimmable, risk of extinguishing lamps in lifetime due to lamp voltage increase<br />
HPI Not dimmable, lamp voltage increase → extinguishing lamps, crack pinch due to low temperature, colour shift<br />
MHN Not dimmable, sever colour instability and risk of crack pinch<br />
CDM Not dimmable, color instability and blackening – exception <strong>for</strong> Lightboost ( new range)<br />
CDM MW Dimmable, systems in introduction phase<br />
<strong>Lighting</strong> Solutions EMEA, July 2011<br />
21
Useful links<br />
<strong>Philips</strong> Guarantee program <strong>for</strong> Lamps & Gear<br />
http://www.philips.com/oem/guarantee<br />
eCat Link to the Outdoor <strong>gear</strong>s Portfolio (<strong>for</strong> CPO, SON, <strong>CDO</strong>)<br />
eCat Link to the CDMe Medium Wattage <strong>gear</strong>s<br />
Link to the <strong>Xtreme</strong> Movie<br />
Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 22
Wiring <strong>DynaVision</strong> <strong>DALI</strong> Drivers<br />
<strong>for</strong> different Control Versions<br />
Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 23
Line Switch<br />
Pilot-line control<br />
Wiring diagram<br />
Earth<br />
N<br />
L<br />
Pilot line<br />
Control cabinet<br />
Extra wire to pole(s)<br />
DA<br />
DA<br />
~<br />
~<br />
L<br />
L<br />
<strong>DynaVision</strong> Xt<br />
<strong>DynaVision</strong> Xt<br />
Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 24<br />
Lamp<br />
GROUP<br />
MANAGEMENT
Presence Sensor<br />
Wiring diagram<br />
Earth<br />
N<br />
L<br />
Presence<br />
detection<br />
DA<br />
DA<br />
~<br />
~<br />
L<br />
L<br />
<strong>DynaVision</strong> Xt<br />
<strong>DynaVision</strong> Xt<br />
Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 25<br />
Lamp<br />
LIGHTPOINT<br />
CONTRIOL
Networked PowerLine - LON<br />
Wiring diagram<br />
ground<br />
Power-line<br />
communication<br />
OLC<br />
<strong>DALI</strong><br />
L<br />
~<br />
N ~<br />
DA<br />
DA<br />
L Lamp<br />
L<br />
<strong>DynaVision</strong> Xt<br />
<strong>DynaVision</strong> Xt<br />
LIGHTPOINT<br />
MANAGEMENT<br />
Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 26
Networked RF<br />
Wiring diagram<br />
Earth<br />
N<br />
L<br />
Wireless<br />
OLC<br />
DA<br />
DA<br />
~<br />
~<br />
L<br />
L<br />
<strong>DynaVision</strong> Xt<br />
<strong>DynaVision</strong> Xt<br />
Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 27<br />
Lamp<br />
LIGHTPOINT<br />
MANAGEMENT
Switch to new technology - Replacement<br />
DV 1-10V<br />
Does the 1-10V<br />
driver needs to<br />
be replaced?<br />
DV <strong>DALI</strong> Xt<br />
Confidential<br />
+<br />
+<br />
SDU 1-10V<br />
SON<br />
<strong>CDO</strong><br />
When the 1-10V driver <strong>for</strong> SON or <strong>CDO</strong> fails, the driver<br />
can be changed <strong>for</strong><br />
• DV <strong>DALI</strong> Xt <strong>for</strong> SON or <strong>CDO</strong> and<br />
• <strong>DALI</strong> Master + Programming Software (one set<br />
<strong>for</strong> all the DV <strong>DALI</strong> Xt programming)<br />
Program the active level<br />
• SDU01 -> Active level = HIGH<br />
• SDU11 -> Active level = LOW<br />
Remove the SDU and 1-10V driver and replace both<br />
with the pre-programmed DV <strong>DALI</strong> Xt<br />
SON<br />
<strong>CDO</strong><br />
CPO<br />
<strong>Lighting</strong> Solutions EMEA, July 2011
Switch to new technology - Replacement<br />
DV 1-10V<br />
Does the 1-10V<br />
driver needs to<br />
be replaced?<br />
Confidential<br />
+<br />
DV <strong>DALI</strong> Xt<br />
Dynadimmer<br />
1-10V<br />
+<br />
+<br />
When the 1-10V driver <strong>for</strong> SON or <strong>CDO</strong> fails, the driver<br />
can be changed <strong>for</strong><br />
• DV <strong>DALI</strong> Xt <strong>for</strong> SON or <strong>CDO</strong> and<br />
Program the dimming scenario<br />
• Read out the Dynadimmer and<br />
• Reproduce the same schedule in the DV <strong>DALI</strong><br />
Xt programming tool<br />
• Program the driver<br />
Remove the Dynadimmer and 1-10V driver and replace<br />
both with the pre-programmed DV <strong>DALI</strong> Xt<br />
SON<br />
<strong>CDO</strong><br />
CPO<br />
SON<br />
<strong>CDO</strong><br />
<strong>Lighting</strong> Solutions EMEA, July 2011
Feature description<br />
1-10V:<br />
Analog input <strong>for</strong> electronic driver, 10V or open is 100%. 0-1V is minimum value of light (level is depending on lamp type)<br />
Benefits: Simple dimming interface<br />
Lumistep:<br />
Pre-programmed dimming sequence controlled by switching on/off. Three different timing available 6, 8 and 10 hours<br />
dimming. Dimming level is fixed on 60% (power)<br />
Benefits: Simple dimming without external control, timing determined by on/off cycle (last 3 nights)<br />
<strong>DALI</strong>:<br />
Universal Digital Addressable <strong>Lighting</strong> Interface.<br />
Defined in standard EN62386, all <strong>Xtreme</strong> drivers are supporting part 101, 102 and 203<br />
Benefits: Digital universal dimming interface to communicate with <strong>DALI</strong> compliant control systems<br />
LineSwitch:<br />
Interface <strong>for</strong> easy dimming via pilot-line or external sensor (presence)<br />
Dimming to preset-level (default 60%) can be controlled by applying directly a 208-277V between <strong>DALI</strong> lines<br />
<strong>DALI</strong> line terminals fully lightning protected (10kV/5kA)<br />
Dim level / speed / inversion can be programmed via <strong>DALI</strong> input (PC-tool required)<br />
Benefits: Simple dimming by extra pilot-line or simple sensor (presence)<br />
Dynadimmer:<br />
All programmable <strong>Xtreme</strong> drivers have an integrated Dynadimmer (5 steps, dim level adjustable)<br />
Dimming sequence, dim levels and speed can be programmed via <strong>DALI</strong> input (PC-tool required)<br />
Benefits: Simple flexible dimming without external control, timing determined by on/off cycle<br />
Adjustable Output Power<br />
Adjustable power Output to regulate light to desired optimum value<br />
Output power can be programmed via <strong>DALI</strong> input (PC-tool required)<br />
Benefits: Adjust right amount of power (light) <strong>for</strong> the application<br />
Confidential <strong>Lighting</strong> Solutions EMEA, July 2011 30